Mark PinTherm Connect Technical Manual

Type
Technical Manual
Technical manual
Technisches Handbuch
Livret technique
Technisch boek
Instrukcja techniczna
Manuel tehnic
EN
DE
FR
NL
PL
MARK PinTherm CONNECT
0664047
RO
OK
RESET
ESC
0
I
PinTherm Connect
06.29.108
MON
DAY
08:01
X:060
18ยบC
06 29 108
2
Read this document before
installing the appliance
Warning
Incorrect installation, adjustment, alteration, repair or maintenance work may lead to material
damage or injury. All work must be carried out by certi๎ƒ€ed, quali๎ƒ€ed professionals. If the
appliance is not positioned in accordance with the instructions, the warranty shall be rendered
void. This appliance is not intended for use by children or persons with a physical, sensory or
mental handicap, or who lack the required experience or expertise, unless they are supervised
or have been instructed in the use of the appliance by somebody who is responsible for their
safety. Children must be supervised to ensure that they do not play with the appliance.
EN
3
1.0 Contents
2.0 General
2.1 All rights reserved page 4
2.2 General warnings page 4
3.0๎€ƒ Technical๎€ƒspeci๎ƒ€cations
3.1 Technical speci๎ƒ€cations PinTherm Connect page 4
3.2 Technical speci๎ƒ€cations external room sensor (optional) page 5
3.3 Resistance chart room sensor (optional) page 5
3.4 Default settings PinTherm Connect page 5
4.0 Installation
4.1 General page 6
4.2 Installation PinTherm Connect page 6
4.3 Installation external room sensor page 6
5.0 Operating manual
5.1 Explanation of the push-buttons and LEDs page 7
5.2 Explanation of the display page 8
5.3 Initial operation of the PinTherm Connect page 8
5.4 Activate user menu page 9
5.5 Enter or change switching times page 9
5.6 Change day/night temperature setting page 10
5.7 Change time and date page 10
5.8 Vacation settings page 10
5.9 Change menu code page 10
5.10 Change language page 11
5.11 Calibration temperature page 11
5.12 Heating/Cooling page 11
5.13 Switching difference page 12
5.14 Changing minimum control signal page 12
5.15 Changing maximum control signal page 12
5.16 Change control signal range page 12
5.17 Modbus page 13
5.18 Ethernet info page 13
5.19 IP settings page 13
5.20 Switch overtime timer on/off page 13
5.21 Switch on chimney-sweep function page 14
5.22 Restore factory settings PinTherm Connect page 14
6.0 Disposing of the PinTherm Connect page 14
7.0 Modbus page 14
8.0 PinTherm Connect connections page 15
Annex I Wiring diagrams page 87
Annex II Modbus page 94
4
2.0 General
2.1 All rights reserved
The manufacturer has a policy of continuous product improvement and reserves the right to
make changes to the speci๎ƒ€cations without prior notice. The technical details are considered
correct but do not form the basis for a contract or warranty. All orders are accepted subject to
the standard terms and conditions of sale and delivery (which will be sent to you at your request).
2.2 General warnings
Installation must comply with the relevant local and/or national regulations. You must therefore
have the PinTherm Connect installed by a professionally quali๎ƒ€ed installer in accordance with
all applicable national and international regulations. Faulty installation, adjustment, alteration,
maintenance activity or repair shall render the warranty void.
Always switch off the 230V power supply before connecting the terminals. The mains voltage
on the PinTherm Connect must be able to be switched off in a double-pole manner by means
of a permanent switch that is suitable for 250VAC / 10A and complies with the applicable safety
regulations.
Only devices that comply with EN-IEC 61010-1 may be operated with the PinTherm Connect.
Clean the housing of the PinTherm Connect with a damp cloth. Do not apply solvents.
There are no requirements regarding ventilation in the immediate vicinity of the controller.
Warning - risk of electric shock.
Warning - general warning, risk of danger.
There can be voltage on the connection terminals where a is placed.
3.0๎€ƒ Technical๎€ƒspeci๎ƒ€cations
3.1 Technical speci๎ƒ€cations PinTherm Connect
โ€ข Type designation : PinTherm Connect
โ€ข Item number : 06 29 108
โ€ข Power supply PinTherm Connect : 90 โ€“ 240 VAC / 47-63Hz
โ€ข Own consumption : < 9W
โ€ข Clock : 24 hour clock with automatic summer/winter time switching
โ€ข Switching programs : 3 switching programs a day
โ€ข Switching differential : 0,1 - 3K
โ€ข Dimensions : 166 x 160 x 106mm (bxwxh)
โ€ข Weight : 880 grammes
โ€ข Protection class : IP-54
โ€ข Installation environment : Transport/storage: -20ยฐC until +70ยฐC.
Operational: -10ยฐC until +60ยฐC
Relative air humidity: 0-90% not condensating
Installation maximal 2000 meter above sea level.
โ€ข Over voltage category : 11
โ€ข Pollution level : 2
โ€ข Switch contact(s)* : Heating: 230Vac/16A (4A)
Others: 230Vac/10A (2,5A)
โ€ข Temperature setting : 0 until 39ยฐC per 1ยฐC adjustable
โ€ข Overtime timer : adjustable 1, 2 or 3 hours (060, 120, 180)
!
!
EN
5
โ€ข Calibration : adjustable from -3.5ยฐC until +3.5ยฐC
โ€ข Heating/cooling : Reversible contact for heating or cooling
โ€ข 0-10 VDC : 0-10 VDC output for heating or cooling
โ€ข Sensor : external room sensor (06 29 086)
โ€ข Languages : NL/EN/DE/FR/PL/RO/LT
โ€ข Fuse : 6A
* The relay contacts are functional switches, not safety switches.
3.2 Technical details external room sensor (optional)
โ€ข Type designation : RSTF NTC4,7K
โ€ข Item number : 06 29 086
โ€ข Resistance : NTC 4K7
โ€ข Dimensions : 79 x 81 x 26mm (lxwxh)
โ€ข Weight : 46 grammes
โ€ข Electrical connection : 0.75 -1.5mmยฒ
โ€ข Protection class : IP-30
3.3 Resistance chart room sensor (optional)
-15ยฐC -10ยฐC -5ยฐC 0ยฐC 5ยฐC 10ยฐC 15ยฐC
32.937kโ„ฆ 25.217kโ„ฆ 19.392kโ„ฆ 15.040kโ„ฆ 11.743kโ„ฆ 9.241kโ„ฆ 7.330kโ„ฆ
20ยฐC 25ยฐC 30ยฐC 35ยฐC 40ยฐC 45ยฐC 50ยฐC
5.855kโ„ฆ 4.700kโ„ฆ 3.777kโ„ฆ 3.071kโ„ฆ 2.512kโ„ฆ 2.066kโ„ฆ 1.709kโ„ฆ
3.4 Default settings PinTherm Connect
โ€ข Menu code : 1000
โ€ข Switching times : MA, DI, WO, DO, VR 07:30-17:30 hours
ZA, ZO 00:00-00:00 hours
โ€ข Room temperature : Day setting 18ยฐC
Night setting 08ยฐC
โ€ข Calibration temp. : +0.0
โ€ข Switching difference : 1K
โ€ข Heating/cooling : Heating
โ€ข 0-10V range : 1K
โ€ข 0-10V min : 0V
โ€ข 0-10V max : 10V
โ€ข Modbus : Slave ID 001
โ€ข IP-setting : static
6
4.0 Installation
4.1 General
After unpacking, check the PinTherm Connect and the external room sensor (if applicable) for
damage. Check that the type/model and the rated voltage are correct.
4.2 Installation PinTherm Connect
Determine a suitable place for installing the PinTherm Connect. Mount the PinTherm Connect
on a solid surface that can carry a minimum of 4 kg. We recommend mounting the PinTherm
Connect at a height of ยฑ1.5m from the ๎ƒoor, at a well reachable place.
For cable gland use only cable glands ๎ƒ€tted with strain relief, with a minimum ๎ƒ€re class of UL94V2.
Check that the power supply has been switched off before connecting any wiring. If this is not the
case, the power supply must be switched off before you continue. When switching off the power
supply of the appliance to which connection is to be made, you should also refer to the technical
documentation/operating instructions for the appliance in question.
Connect the PinTherm Connect according to one of the supplied electrical diagrams which are in
the back of this technical book. To select the correct connection diagram, you need to know on
which type of device you will connect the PinTherm Connect. For a selection see also Annex I.
When applying a 0-10VDC signal, see the table below for the correct cable diameter and
associated length.
Diameter Length
0.8mm
2
80 meter
1.0mm
2
100 meter In this case, we advise the use of a shielded cable.
1.5mm
2
150 meter
4.3 Installation external room sensor
Place the external room sensor draft-free, in view of the appliance at a height of approx. 1.5m
from the ๎ƒoor. And connect the sensor to the appropriate terminals in the PinTherm Connect.
Refer to the chart below for the correct wire diameter and length.
Diameter Length
0.8mm
2
80 meter
1.0mm
2
100 meter In this case, we advise the use of a shielded cable.
1.5mm
2
150 meter
EN
7
5.0 Operating manual
5.1 Explanation of the push-buttons and LEDs
A - Illuminated display (see also 5.2)
B - Push-button for switching the heating mode on and off.
C - LED, lit when the heating mode is active.
D - Push-button for switching the continuous ventilation mode on and off.
E - LED, lit when the continuous ventilation mode is active.
F - Push-button for switching the appliance out of lock-out after a (burner) fault.
G - LED, lit when a (burner) fault has been detected.
H - Push-button for activating the user menu or to display the next value.
I - Push-button for con๎ƒ€rming a selection/change or for displaying the next menu item.
J - Push-button for exiting the setting or menu without executing a change.
K - Push-button for switching the overtime timer on and off.
L - Push-button ๏€ต+๏€ถ โ€“ to change a setting.
M - LED, lit when there is heat demand in the heating mode (burner on).
N - LED, lit when the fan is switched on.
O - LED, lit when the overtime timer function is active.
C
OK
PinTherm Connect
06.29.108
MON
DAY
08:01
E
G
M
N
O
D
F
J K LI
A
B
H
RESET
ESC
0
I
18ยบC
X:060
8
5.2 Explanation of the display
A - Indicates the day of the week.
B - The current clock time is shown here.
C - Indicates the measured temperature (ยฐC).
D - Indicates the number of minutes before the overtime timer function is switched off again and
the PinTherm Connect will return to night temperature control mode.
E - Indicates whether the PinTherm Connect is set to daytime mode (DAY) or to night mode
(NIGHT) and temperature control based on the daytime or night temperature setting.
5.3 Initial operation of the PinTherm Connect
When you connect a power supply to the PinTherm Connect for the ๎ƒ€rst time, you will be asked
to select your choice of language (language settings: NL, EN, DE, FR, PL, RO, LT). Having done
so, the next step is to set the time and date. After the time and date have been set, the PinTherm
Connect displays the main screen.
Language options: NL, EN, DE, FR, PL, RO, LT
C
MA
DAG
08:01
E
D
B
A
18ยบC
X:060
SELECT LANGUAGE SAT 01-01-2006
00:00:00
16ยฐCMON
DAY
08:00
changes the
๎€Ÿashing digit
to go one digit up
select the desired
language
OK OK
ENGLISH
EN
9
5.4 Activate user menu
You can change the following settings in the menu:
โ€“ Enter/change switching times
โ€“ Change day/night setting
โ€“ Change time/date
โ€“ Vacation settings
โ€“ Change menu code
โ€“ Change language
โ€“ Calibration
โ€“ 0-10V min 0-5V
โ€“ 0-10V max 5-10V
โ€“ 0-10V range (1-3)
โ€“ Modbus
โ€“ IP settings
5.5 Enter or change switching times
ENTER MENU CODE
leave the menu and go back
to the main screen
Default setting Menu
code
1000
ยฐCMON
DAY
08:01
changes the flashing
digit
to go one digit up
make your menu choice
with these buttons
ESC
OK OK
0000
SET/CHANGE
PROGRAM
MONDAY
etc.
back to the
menu
changes the
flashing digit
to go up one digit
OK
OK
OK
07:30 -> 17:00
SET/CHANGE
PROGRAM
MONDAY
OK
--:-- -> --:--
changes the
flashing digit
to go up one digit
OK
12
MONDAY
--:-- -> --:--
3 TUESDAY
07:30 -> 17:00
1 SUNDAY
--:-- -> --:--
3
10
5.6 Change day/night temperature setting
5.7 Change time and date
5.8 Vacation settings
During the set time block, the control will regulate according to the night temperature.
5.9 Change menu code
VACATION ACTIVE
ON
back to the
menu
select
select
on or off
OK OK
VACATION SETTING
FROM: 01-07-2017
TILL: 01-08-2017
OK
changes the
flashing light
to go up one digit
18ยฐC
DAY SETTING
NIGHT SETTING
select
back to the
menu
changes the
flashing digit
to go one digit up
changes the
flashing digit
to go one digit up
OK OK
OK
08ยฐC
SET/CHANGE
TEMPERATURE
MON 23-03-2009
09:10:00
back to the
menu
select
changes the
flashing digit
to go one digit up
OK OK
CHANGE
TIME/DATE
1000
CHANGE MENU CODE
SELECT NEW CODE
New menu code
back to the
menu
select
changes the
flashing digit
to go one digit up
OK OK
EN
11
5.10 Change language
Language options: NL, EN, DE, FR, PL, RO, LT.
5.11 Calibration temperature
If the external room sensor is installed in an unfavourable position, the actual temperature and the
temperature measured by the PinTherm Connect may differ. This temperature difference can be
compensated by setting a correction factor in this temperature calibration function.
For example: The measured temperature is 18ยฐC, but the PinTherm Connect display
indicates 20ยฐC. The difference in this example is 2ยฐC too high.
The correction value must be set to -2ยฐC.
5.12 Heating/Cooling
Setting to make the controller suitable for controlling heating or cooling.
HEATING/COOLING
HEATING
back to
the menu
select
change setting
OK
HEATING/COOLING
OK
ENGLISH
SELECT LANGUAGE
back to the
menu
select the desired
language
select
OK OK
CHANGE LANGUAGE
CALIB. TEMP. CALIB. TEMP.
Correctionvalue is adjustable
back to the
menu
select
changes the
flashing digit
to go one digit up
OK OK
+ 0.0ยฐC
from -3,5ยฐC to +3,5ยฐC
12
5.13 Switching difference
Adjustable between 0.1 and 3.0 K.
5.14 Change minimum control signal
Note:
When there is no demand for heat, the PinTherm Connect sends out a signal of 0VDC.
5.15 Change maximum control signal
5.16 Change control signal range
This function determines when the 0 โ€“ 10VDC signal is modulated back in conditions of heat
demand. When set to 1.0, the PinTherm Connect will start to modulate the 0 - 10V signal at 1K
below the target temperature.
The range can be set between 0.5 โ€“ 3.0 and is set to 1.0 as standard.
SWITCHING DIFF.
1.0K
back to
the menu
select
changes the
flashing digit
OK
SWITCHING DIFF.
OK
select
change setting
OK OK
0-10V min(0-5V)
2.0 V
0-10V min(0-5V)
back to
the menu
select
change setting
OK OK
0-10V max(5-10V)
10.0 V
0-10V max(5-10V)
back to
the menu
back to
the menu
select
change setting
OK OK
0-10V Range(1-3)
1.0
0-10V Range(1-3)
EN
13
5.17 ModBus
Slave ID: adjustable 1 - 247
Factory setting: 1
5.18 Ethernet Info
Display set IP address.
5.19 IP settings
DHCP - automatic assignment IP address
Static - set ๎ƒ€xed IP address
SUBnet Mask
5.20 Switch overtime timer on/off
This function provides the option of manually switching to the daytime temperature outside the
set switching times for a period of 1, 2 or 3 hours.
The yellow LED with the symbol is lit when this function is active. In addition, the bottom
right of the display shows the time in minutes that still remains before the function is deactivated
and the PinTherm Connect returns to night temperature control. The function can also be swit-
ched off prematurely by pressing the push-button again until the yellow LED extinguishes and the
number of remaining minutes disappears from the display.
IP ADDRESS
192.168.001.100
back to the
menu
select
OK OK
ETHERNET INFO
MAC ADDRESS
5410EC220037
OK
IP MODE
STATIQ
back to the
menu
select
OK OK
IP SETTINGS
IP ADDRESS
192.168.001.100
OK
change setting
changes the
flashing digit
to go one digit up
SUBNET MASK
255.255.255.000
changes the
flashing digit
to go one digit up
MODBUS SETTINGS
001
back to the
menu
select
changes the
flashing digit
OK
MODBUS SETTINGS
OK
to go one digit up
14
See the illustration below.
5.21 Switch on chimney-sweep function
You can use this function to switch the appliance temporarily to full heat output/partial heat
output so that measurements can be taken. Refer to the information below for instructions on
how to switch this function on and off. After activation, this function remains switched on for 15
minutes and will switch off automatically again after that period.
5.22 Restore factory settings PinTherm Connect
All the factory settings are restored when you activate this function. This function may be
activated at any time. See the illustration below.
6.0 Disposing of the PinTherm Connect
When the PinTherm Connect is replaced or removed, it must be recycled or destroyed in
accordance with national and/or local legislation and regulations.
7.0 Modbus
- Communication [12]
- Modbus-list [13]
NIGHT
MON
X:060
18ยฐC
MON
DAY
17:01
X:120
MON
DAY
17:01
X:180
MON
DAY
17:01
17:01
18ยฐC
18ยฐC
18ยฐC
This switches the function o๎€Ÿ and takes you back
to the main screen
ESC
0-10V
10V
14:59
press to increase the voltage (maximum of 10V)
Use the push-buttons referred to below to have the
appliance run at a lower voltage (reduce the heat output)
press to lower the voltage
Press and hold down
for ยฑ12 seconds
0
keep pressed or
+/- 12 secs
SELECT LANGUAGE
16ยฐCMON
DAY
08:01
This will return you to the
screen from which you
selected this function and
default settings will not be
restored.
OK OK
ESC
ENGLISH
DEFAULT SETTINGS
RESTORED!
RESET TO DEFAULT
SETTINGS?
EN
15
8.0 PinTherm Connect connections
L N Connection terminals (230Vac/50Hz)
21 - 22 Continuous ventilation
21 - 23 Heating/cooling
24 - 25 Fault signal
25 - 26 Reset
+ - 0-10Vdc (Heating/cooling)
11 - 12 External room sensor
A - B MODBUS RTU (R ground)
RJ 45 connector Internet / Modbus TCP/IP
13 - 14 Contact external fan
Warning: Dangerous voltage present on N, L, 13, 14, 21, 22, 23, 24, 25 and 26
With the PinTherm Connect, only devices that comply with the safety regulations as laid down in
EN-IEC 61010-1 may be controlled.
PinTherm Connect
06.29.108
MON
DAY
08:01 18ยบC
X:060
OK
RESET
ESC
0
I
16
Lesen Sie dieses Dokument sorgfรคltig
durch, bevor Sie das Gerรคt installieren
Warnhinweis
Fehlerhaft durchgefรผhrte Installationen, Einstellungen, ร„nderungen, Reparaturen oder
WartungsmaรŸnahmen kรถnnen zu Sachschรคden und Verletzungen fรผhren. Alle Arbeiten
mรผssen von geprรผften, quali๎ƒ€zierten Fachleuten durchgefรผhrt werden. Falls das Gerรคt nicht
vorschriftsgemรครŸ aufgestellt wird, erlischt die Garantie. Dieses Gerรคt ist nicht fรผr den Gebrauch
durch Personen (einschlieรŸlich Kindern) mit verminderter kรถrperlicher, Sinnes- oder geistiger
Leistungsfรคhigkeit oder mangelnder Erfahrung und mangelnden Kenntnissen bestimmt, sofern sie
nicht unter Aufsicht stehen oder durch eine Person, die fรผr ihre Sicherheit verantwortlich ist, im
Gebrauch des Gerรคts angeleitet werden. Kinder mรผssen vom Gerรคt ferngehalten werden.
17
DE
1.0 Inhalt
2.0 Allgemeines
2.1 ร„nderungen vorbehalten Seite 18
2.2 Allgemeine Warnhinweise Seite 18
3.0 Technische Daten
3.1 Technische Daten PinTherm Connect Seite 18
3.2 Technische Daten externer Raumfรผhler (optional) Seite 19
3.3 Widerstandstabelle (externer) Raumfรผhler Seite 19
3.4 Werkseinstellungen PinTherm Connect Seite 19
4.0 Montage
4.1 Allgemeines Seite 20
4.2 Montage PinTherm Connect Seite 20
4.3 Montage eines externen Raumfรผhlers (optional) Seite 20
5.0 Bedienungsanleitung
5.1 Erlรคuterung der Drucktasten und LEDs Seite 21
5.2 Erlรคuterung des Displays Seite 22
5.3 Erste Inbetriebnahme der PinTherm Connect Seite 22
5.4 Aktivierung des Benutzermenรผs Seite 23
5.5 Schaltzeiten eingeben oder รคndern Seite 23
5.6 Tages- und Nachttemperatur รคndern Seite 24
5.7 Uhrzeit und Datum รคndern Seite 24
5.8 Einstellung der Urlaubsreglung Seite 24
5.9 Menรผcode รคndern Seite 24
5.10 Sprachauswahl รคndern Seite 25
5.11 Justierung Seite 25
5.12 Heizen / Kรผhlen Seite 25
5.13 Schaltdifferenz Seite 26
5.14 Minimumregelsignal รคndern Seite 26
5.15 Maximumregelsignal รคndern Seite 26
5.16 Bereich Minimumregelsignal รคndern Seite 26
5.17 Modbus Seite 27
5.18 Ethernet Info Seite 27
5.19 IP-Einstellungen Seite 27
5.20 รœberstundenzรคhler ein-/ausschalten Seite 27
5.21 Schornsteinfegerfunktion einschalten Seite 28
5.22 Werkseinstellungen der PinTherm Connect wiederherstellen Seite 28
6.0 Entsorgung der PinTherm Connect Seite 28
7.0 Modbus Seite 28
8.0 Anschlussmรถglichkeiten der PinTherm Connect Seite 29
Anhang I Anschlussschema Seite 87
Anhang II Modbus Seite 94
18
2.0 Allgemeines
2.1 ร„nderungen vorbehalten
Der Hersteller strebt eine kontinuierliche Verbesserung der Produkte an und behรคlt sich das
Recht vor, ohne vorherige Mitteilung, ร„nderungen an den technischen Daten vorzunehmen.
Die technischen Angaben werden als korrekt angenommen, bilden aber keine Grundlage
fรผr einen Vertrag oder Gewรคhrleistungsansprรผche. Alle Bestellungen werden gemรครŸ den
Standardkonditionen in unseren allgemeinen Verkaufs- und Lieferbedingungen angenommen (diese
werden auf Anfrage zur Verfรผgung gestellt).
2.2 Allgemeine Warnhinweise
Die Installation muss den geltenden landesweiten und รถrtlichen Bestimmungen entsprechen.
Daher darf das Gerรคt nur von einem sachkundigen und quali๎ƒ€zierten Installateur unter Beachtung
der nationalen und internationalen Vorschriften installiert werden. Im Falle einer unsachgemรครŸen
Installation, Einstellung, ร„nderung, Wartung oder Instandsetzung erlischt die Gewรคhrleistung.
Vor dem Aufschrauben der Klemmen immer die 230V-Stromversorgung ausschalten. Die
Netzspannung am PinTherm Connect muss durch einen permanenten Schalter, der fรผr 250VAC /
10A geeignet ist und die geltenden Sicherheitsvorschriften erfรผllt, zweipolig abgeschaltet werden
kรถnnen.
Nur Gerรคte, die EN-IEC 61010-1 entsprechen, dรผrfen mit dem PinTherm Connect betrieben
werden.
Reinigen Sie das Gehรคuse des PinTherm Connect mit einem feuchten Tuch. Keine Lรถsungsmittel
auftragen.
Es gibt keine Anforderungen an die Belรผftung in unmittelbarer Nรคhe des Reglers.
Warnung - Gefahr eines Stromschlags.
Warnung - Allgemeine Warnung
Die Stromanschlรผsse kรถnnen an den Anschlussklemmen vorgenommen werden, an denen sich
einer
!
be๎ƒ€ndet.
3.0 Technische Daten
3.1 Technische Daten PinTherm Connect
โ€ข Typbezeichnung : PinTherm Connect
โ€ข Artikelnummer : 06 29 108
โ€ข Spannungsversorgung : 90 โ€“ 240 VAC / 47-63Hz
โ€ข Eigenverbrauch : < 9W
โ€ข Uhr : 24 Std. Uhr mit automatischer Umstellung auf Sommer und
Winterzeit
โ€ข Schaltprogramm : 3 Schaltprogramme pro Tag
โ€ข Schaltdifferenz : 0,1 - 3K
โ€ข GrรถรŸe : 166 x 160 x 106mm (LxBxH)
โ€ข Gewicht : 880 Gramm
โ€ข Schutzart : IP54
โ€ข Installationsumgebung : Transport / Lagerung: -20 ยฐ C bis + 70 ยฐ C
Betrieb: -10 ยฐ C bis + 60 ยฐ C
Relative Luftfeuchtigkeit: 0-90% nicht kondensierend
Installation maximal 2000 Meter รผber dem Meeresspiegel.
!
19
DE
โ€ข รœberspannungskategorie : 11
โ€ข Verschmutzungsgrad : 2
โ€ข Schaltkontakt:* : Heizung: 230Vac/16A (4A)
Andere: 230Vac/10A (2,5A)
โ€ข Temperatureinstellung : 0 bis 39 ยฐC pro 1ยฐC einstellbar
โ€ข รœberstunden-Timer : einstellbar 1, 2 oder 3 Stunden (060,120,180)
โ€ข Kalibrierung : einstellbar von -3,5 ยฐ C bis + 3,5 ยฐ C
โ€ข Heizen /Kรผhlen : Umschaltkontakt zum Heizen oder Kรผhlen
โ€ข 0-10 VDC : 0-10 VDC Ausgang zum Heizen oder Kรผhlen
โ€ข Fรผhler : externer Raumfรผhler (06 29 086)
โ€ข Einstellbare Sprachen : NL/EN/DE/FR/PL/RO/LT
โ€ข Vorsicherung : 6A
* Die Relaiskontakte sind Funktionsschalter, keine Sicherheitsschalter.
3.2 Technische Daten externer Raumfรผhler (optional)
โ€ข Typbezeichnung : RSTF NTC4,7K
โ€ข Artikelnummer : 06 29 086
โ€ข Widerstand : NTC 4K7
โ€ข Abmessungen : 79 x 81 x 26mm (L x B x H)
โ€ข Gewicht : 46 Gramm
โ€ข Elektrischer Anschluss : 0.75 -1.5mmยฒ
โ€ข Schutzgrad : IP-30
3.3 Widerstandstabelle (externer) Raumfรผhler
-15ยฐC -10ยฐC -5ยฐC 0ยฐC 5ยฐC 10ยฐC 15ยฐC
32.937kโ„ฆ 25.217kโ„ฆ 19.392kโ„ฆ 15.040kโ„ฆ 11.743kโ„ฆ 9.241kโ„ฆ 7.330kโ„ฆ
20ยฐC 25ยฐC 30ยฐC 35ยฐC 40ยฐC 45ยฐC 50ยฐC
5.855kโ„ฆ 4.700kโ„ฆ 3.777kโ„ฆ 3.071kโ„ฆ 2.512kโ„ฆ 2.066kโ„ฆ 1.709kโ„ฆ
3.4 Werkseinstellungen PinTherm Connect
โ€ข Menรผcode : 1000
โ€ข Schaltzeiten : MA, DI, WO, DO, VR 07:30-17:30 Uhr
ZA, ZO 00:00-00:00 Uhr
โ€ข Raumtemperatur : Tagestemperatur 18ยฐC
Nachttemperatur 08ยฐC
โ€ข Justierung : +0.0
โ€ข Schaltdifferenz : 1K
โ€ข Heizen / Kรผhlen : Heizen
โ€ข 0-10V range : 1K
โ€ข 0-10V min : 0V
โ€ข 0-10V max : 10V
โ€ข Modbus : Slave ID 001
โ€ข IP-Einstellungen : statisch
20
4.0 Montage
4.1 Allgemeines
Prรผfen Sie nach dem auspacken der PinTherm Connect und - falls bestellt - den mitgelieferten
externen Raumfรผhler auf Beschรคdigungen. รœberprรผfen Sie die Richtigkeit des gelieferten Typs/
Models sowie die elektrische Spannung.
4.2 Montage des PinTherm Connect
Legen Sie einen geeigneten Ort fรผr den Einbau der PinTherm Connect fest. Montieren Sie den
PinTherm Connect auf einer Ober๎ƒรคche, die mindestens 4kg tragen kann. Es wird empfohlen, die
PinTherm Connect auf ยฑ 1,5 m รผber dem FuรŸboden anzubringen, an einem leicht zugรคnglichen
Ort.
Verwenden Sie fรผr die Kabeleinfรผhrung nur Kabelverschraubungen mit einen Zugentlastung
der Mindestbrandklasse UL94V2. Stellen Sie sicher, dass die Stromversorgung ausgeschaltet
ist, bevor Sie ein Kabel anschlieรŸen. Sollte dies nicht der Fall sein, muss die Stromversorgung
ausgeschaltet werden. Beziehen Sie vor dem Ausschalten der Stromversorgung auf die jeweilige
Bedienungsanleitung des Gerรคtes.
SchlieรŸen Sie den PinTherm Connect gemรครŸ einem der mitgelieferten Schaltplรคne an. Diese
๎ƒ€nden Sie auf der Rรผckseite des technischen Handbuchs. Um das richtige Verbindungsdiagramm
auszuwรคhlen, mรผssen Sie wissen, an welchem Gerรคtetyp Sie den PinTherm Connect anschlieรŸen.
Fรผr eine Auswahl siehe auch Anhang I.
Wenn ein 0-10VDC-Signal angelegt wird, Siehe nachfolgende Tabelle fรผr den richtigen
Kabeldurchmesser und die richtige Lรคnge.
Durchmesser Lรคnge
0.8mm
2
80 m
1.0mm
2
100 m Es wird empfohlen, hierfรผr ein geschirmtes Kabel zu
1.5mm
2
150 m verwenden.
4.3 Montage eines externen Raumfรผhlers (optional)
Platzieren Sie den externen Raumfรผhler geschรผtzt in Sichtweite des Gerรคtes in einer Hรถhe von ca.
1,5 Meter, gemessen ab dem Boden. SchlieรŸen Sie den Sensor an die entsprechenden Klemmen
im PinTherm Connect an. Siehe nachfolgende Tabelle fรผr den richtigen Kabeldurchmesser und die
richtige Lรคnge.
Durchmesser Lรคnge
0.8mm
2
80 m
1.0mm
2
100 m Es wird empfohlen, hierfรผr ein geschirmtes Kabel zu
1.5mm
2
150 m verwenden.
21
DE
5.0 Bedienungsanleitung
5.1 Erlรคuterung der Drucktasten und LEDs
A - Beleuchtete Anzeige (siehe auch 5.2)
B - Drucktaste zum Ein- oder Ausschalten der Erwรคrmungsstufe.
C - LED leuchtet auf, wenn die Funktion โ€žErwรคrmenโ€ eingeschaltet ist.
D - Drucktaste zum Ein- und Ausschalten der Stellung Lรผften.
E - Die LED leuchtet auf, wenn die Lรผftungsfunktion eingeschaltet ist.
F - Drucktaste, um das Gerรคt im Fall einer (Brenner-)Stรถrung zu entsperren.
G - LED leuchtet im Fall einer (Brenner-)Stรถrung.
H - Drucktaste, um das Benutzermenรผ zu aktivieren oder um zum nรคchsten Punkt zu gehen.
I - Drucktaste, um eine durchgefรผhrte Wahl/ร„nderung zu bestรคtigen oder um zum nรคchsten
Menรผpunkt zu gehen.
J - Drucktaste, um das Menรผ oder die Eiinstellung zu verlassen, ohne eine ร„nderung durch
zufรผhren.
K - Drucktaste, um den รœberstundenzรคhler ein- oder auszuschalten.
L - Schalt๎ƒรคche ๏€ต+๏€ถ โ€“ um eine Einstellung zu รคndern.
M - LED leuchtet bei Wรคrmebedarf in der Stufe Erwรคrmen (Brenner ein) auf.
N - Die LED leuchtet auf, wenn der Lรผfter eingeschaltet ist.
O - LED leuchtet auf, wenn die Funktion รœberstundenzรคhler eingeschaltet ist.
C
OK
PinTherm Connect
06.29.108
MO
TAG
08:01
E
G
M
N
O
D
F
J K LI
A
B
H
RESET
ESC
0
I
18ยบC
X:060
22
5.2 Erlรคuterung des Displays
A - Zeigt den Wochentag an.
B - Zeigt die aktuelle Uhrzeit an.
C - Zeigt die gemessene Temperatur (ยฐC) an.
D - Zeigt die Anzahl der Minuten an, bevor die Funktion รœberstundenzรคhler wieder
ausgeschaltet wird und die PinTherm Connect in der Nachttemperaturstellung arbeitet.
E - Zeigt an, ob die PinTherm Connect in der Tagesstellung (TAG) oder Nachtstellung
(NACHT) steht und in der Tag- oder Nachttemperaturstellung arbeitet.
5.3 Erste Inbetriebnahme der PinTherm Connect
Wenn Sie die PinTherm Connect das erste Mal einschalten, werden Sie aufgefordert, die gewรผn-
schte Sprache zu wรคhlen (einstellbare Sprachen: Niederlรคndisch, Englisch, Deutsch, Franzรถsisch,
Italienisch und Polnisch). AnschlieรŸend mรผssen Sie Zeit und Datum einstellen. Dann kehrt die
PinTherm Connect zum Hauptbildschirm zurรผck.
Einstellbare Sprachen: NL, EN, DE, FR, PL, RO, LT
C
MO
TAG
08:01
E
D
B
A
18ยบC
X:060
SELECT LANGUAGE SA 01-01-2006
00:00:00
16ยฐCMO
TAG
08:00
ร„ndert die
blinkende Zi๎€“er
Zur folgende Zi๎€“er gehen
Gewรผnschte
Sprache uswรคhlen
OK OK
ENGLISH
23
DE
5.4 Aktivierung des Benutzermenรผs
Im Menรผ kรถnnen die folgenden Einstellungen vorgenommen werden:
โ€“ Schaltzeiten eingeben/รคndern
โ€“ Tages- und Nachttemperatur รคndern
โ€“ Uhrzeit/Datum รคndern
โ€“ Urlaubsreglung
โ€“ Menรผcode รคndern
โ€“ Sprachauswahl รคndern
โ€“ Justierung
โ€“ 0-10V min 0-5V
โ€“ 0-10V max 5-10V
โ€“ 0-10V range (1-3)
โ€“ Modbus
โ€“ IP-Einstellungen
5.5 Schaltzeiten eingeben oder รคndern
CODE EINGEBEN
das Menรผ verlassen und zum
Hauptbildschirm zurรผckkehren
Menรผcode
werkeinstellung
1000
ยฐCMO
TAG
08:01
ร„ndert die blinkende
Ziffer
Zur folgende Ziffer gehen
Hiermit treffen Sie die
gewรผnschte Wahl in Menรผ.
ESC
OK OK
0000
PROGRAMM
EINGEBEN/ANDERN
MONTAG
usw.
zurรผck zum
Menรผ
ร„ndert die
blinkende Ziffer
Zur folgende Ziffer gehen
OK
OK
OK
07:30 -> 17:00
PROGRAMM
EINGEBEN/ร„NDERN
MONTAG
OK
--:-- -> --:--
ร„ndert die
blinkende Ziffer
Zur folgende Ziffer gehen
OK
MONTAG
--:-- -> --:--
3 DIENSTAG
07:30 -> 17:00
1 SONNTAG
--:-- -> --:--
3
24
5.6 Tages- und Nachttemperatur รคndern
5.7 Uhrzeit und Datum รคndern
5.8 Einstellung der Urlaubsreglung
Wรคhrend des eingestellten Zeitblocks regelt die Steuerung entsprechend die Nachttemperatur.
5.9 Menรผcode รคndern
URL.EINST.AKTIV
AN
zurรผck zum
Menรผ
auswรคhlen
Wรคhlen Sie den
Ein oder Aus
OK OK
URLAUBS-
EINSTELLUNG
VON: 01-07-2017
BIS: 01-08-2017
OK
ร„ndert die
blinkende Ziffer
Zur folgende
Ziffer gehen
18ยฐC
TAGESTEMPERATUR
NACHTTEMPERATUR
auswรคhlen
zurรผck zum
Menรผ
ร„ndert die
blinkende Ziffer
Zur folgende Ziffer gehen
ร„ndert die
blinkende Ziffer
Zur folgende Ziffer gehen
OK OK
OK
08ยฐC
SOLLTEMPERATUR
MO 23-03-2009
09:10:00
zurรผck zum
Menรผ
auswรคhlen
ร„ndert die
blinkende Ziffer
Zur folgende Ziffer gehen
OK OK
DATUM/ZEIT
ร„NDERN
1000
CODE ร„NDERN
CODE NEU Wร„HLEN
Neuer Menรผcode
zurรผck zum
Menรผ
auswรคhlen
ร„ndert die
blinkende Ziffer
Zur folgende Ziffer gehen
OK OK
25
DE
5.10 Sprachauswahl รคndern
Einstellbare Sprachen: NL, EN, DE, FR, PL, RO, LT.
5.11 Justierung
Wenn die PinTherm Connect an einem ungeeigneten Ort montiert wird, kann eine Abweichung
gegenรผber der tatsรคchlich gemessenen PinTherm Connect-Temperatur auftreten. Dieser
Temperaturunterschied kann mit der Kalibrierungsfunktion angepasst werden, indem ein
Korrekturwert eingestellt wird.
Beispiel: Die gemessene Temperatur betrรคgt 18 ยฐC, der Bildschirm auf der Pin Therm+ zeigt
20 ยฐC an. Die Differenz betrรคgt in diesem Beispiel also 2 ยฐC zu viel als Korrekturwert
muss -2ยฐ C eingestellt werden.
5.12 Heizen / Kรผhlen
Einstellug des Reglers zum Heizen oder Kรผhlen.
HEIZEN/KUHLEN
HEIZEN
zurรผck zum
Menรผ
auswรคhlen
Einstellung รคndern
OK
HEIZEN/KUHLEN
OK
DEUTSCH
SPRACHE Wร„HLEN
zurรผck zum
Menรผ
Gewรผnschte
Sprache uswรคhlen
auswรคhlen
OK OK
SPRACHE ร„NDERN
KALIB. TEMP. KALIB. TEMP.
Korrekturwert ist einstellbar
zurรผck zum
Menรผ
auswรคhlen
ร„ndert die
blinkende Ziffer
Zur folgende Ziffer gehen
OK OK
+ 0.0ยฐC
von -3,5ยฐC bis +3,5ยฐC
26
5.13 Schaltdifferenz
Einstellbar zwischen 0,1 und 3,0 K.
5.14 Minimumregelsignal รคndern
Anmerkung:
Wenn keine Wรคrmeanforderung vorliegt, sendet das PinTherm Connect 0 VDC.
5.15 Maximumregelsignal รคndern
5.16 Bereich Minimumregelsignal รคndern
Mit dieser Funktion wird festgelegt, wann das 0-10 VDC-Signal wรคhrend einer Wรคrmeanforderung
zurรผckmoduliert wird. Wenn dies auf 1,0 eingestellt ist, wird die PinTherm Connect 1K unter der
Solltemperatur das 0-10 V-Signal zurรผckmodulieren.
Der Bereich ist einstellbar von 0,5 โ€“ 3,0 und ist standardmรครŸig auf 1,0 eingestellt.
SCHALTDIFFERENZ
1.0K
zurรผck zum
Menรผ
auswรคhlen
ร„ndert die
blinkende Ziffer
OK
SCHALTDIFFERENZ
OK
auswรคhlen
Einstellung รคndern
OK OK
0-10V min(0-5V)
2.0 V
0-10V min(0-5V)
zurรผck
zum Menรผ
auswรคhlen
Einstellung รคndern
OK OK
0-10V max(5-10V)
10.0 V
0-10V max(5-10V)
zurรผck
zum Menรผ
zurรผck
zum Menรผ
auswรคhlen
Einstellung รคndern
OK OK
0-10V Bereich (1-3)
1.0
0-10V Bereich (1-3)
27
DE
5.17 ModBus
Slave-ID: einstellbar 1 - 247
Werkseinstellung: 1
5.18 Ethernet Info
Zeigt die eingestellte IP-Adresse an.
5.19 IP-Einstellungen
DHCP - automatische Zuweisung der IP-Adresse
Statisch - festeingestellte IP Adresse
SUBnet Maske
5.20 รœberstundenzรคhler ein-/ausschalten
Mit dieser Funktion kann man ungeachtet der eingestellten Schaltzeiten manuell 1, 2 oder 3
Stunden auf die Tagestemperatur umschalten.
Die gelbe LED Anzeige mit dem Symbol leuchtet, wenn diese Funktion eingeschaltet ist. Wei-
terhin wird auf dem Display rechts unten die verbleibende Zeit in Minuten angezeigt, bevor die
Funktion wieder ausschaltet und die PinTherm Connect wieder mit der Nachttemperatur arbeitet.
Die Funktion kann auch zwischenzeitlich wieder ausgeschaltet werden, indem die Drucktaste
nochmals gedrรผckt wird, bis die gelbe LED Anzeige erlischt und die Anzahl der Minuten nicht
IP-ADRESSE
192.168.001.100
zurรผck zum
Menรผ
auswรคhlen
OK OK
ETHERNET INFO
(LAN)
MAC ADRESSE
5410EC220037
OK
IP MODUS
STATISCH
zurรผck zum
Menรผ
auswรคhlen
OK OK
IP EINSTELLUNG
IP-ADRESSE
192.168.001.100
OK
Einstellung รคndern
ร„ndert die
blinkende Ziffer
Zur folgende
Ziffer gehen
SUBNETZMASKE
255.255.255.000
ร„ndert die
blinkende Ziffer
Zur folgende
Ziffer gehen
MODBUS SLAVE ID
001
zurรผck zum
Menรผ
auswรคhlen
ร„ndert die
blinkende Ziffer
OK
MODBUS
EINSTELLUNG
OK
Zur folgende
Ziffer gehen
28
mehr auf dem Display angezeigt wird. Siehe folgende Abbildung.
5.21 Schornsteinfegerfunktion einschalten
Hiermit kรถnnen Sie das Gerรคt kurzzeitig in Volllast/Teillast heizen lassen, um Messungen usw. dur-
chfรผhren zu kรถnnen. Nachfolgend ist angegeben, wie Sie diese Funktion ein- und ausschalten kรถn-
nen. Nach dem Einschalten bleibt diese Funktion 15 Minuten aktiv und schaltet sich anschlieรŸend
automatisch wieder aus.
5.22 Werkseinstellungen der PinTherm Connect wiederherstellen
Durch diese Funktion wird alles auf die Werkseinstellungen zurรผckgesetzt. Diese Funktion kann
jederzeit ausgefรผhrt werden. Siehe folgende Abbildung.
6.0 Entsorgung der PinTherm Connect
Wenn das PinTherm Connect ersetzt oder entfernt wird, muss es gemรครŸ den รผberregionalen
oder lokalen Vorschriften entsorgt oder vernichtet werden.
7.0 Modbus
- Kommunikation [12]
- Modbus Liste [13]
NACHT
MO
X:060
18ยฐC
MO
TAG
17:01
X:120
MO
TAG
17:01
X:180
MO
TAG
17:01
17:01
18ยฐC
18ยฐC
18ยฐC
Hiermit beenden Sie die Funktion und kehren
Sie zum Hauptbildschirm zurรผck
ESC
0-10V
10V
14:59
drรผcken, um die Spannung zu erhรถhen (max. 10 V)
Verwenden Sie die nachfolgenden Drucktasten, um das Gerรคt
mit einer niedrigeren Spannung (Teillast) laufen zu lassen.
drรผcken, um die Spannung zu erniedrigen
ca. 12 s gedrรผckt
halten
0
ยฑ 12 sek. Gedrรผckt
halten
SELECT LANGUAGE
16ยฐCMO
TAG
08:01
Hiermit kehren Sie zum
Hauptbildschirm zurรผck.
Und es wird nicht auf die
Werkeinstellungen
zurรผckgesetzt!
OK OK
ESC
ENGLISH
WERKEINSTELLUNG
HERGESTELLT
WERKEINSTELLUNG
HERSTELLEN?
29
DE
8.0 Anschlussmรถglichkeiten der PinTherm Connect
L N Anschlussklemmen (230Vac/50Hz)
21 - 22 Kontinuirliche Belรผftung
21 - 23 Heizen / Kรผhlen
24 - 25 Stรถrungsleuchte
25 - 26 Rรผcksetzkontakt
+ - 0-10Vdc (Heizen / Kรผhlen)
11 - 12 externer Raumfรผhler
A - B MODBUS RTU (R ground)
RJ 45 connector Internet / Modbus TCP/IP
13 - 14 Kontakt zum externen Ventilator
Warnung: Gefรคhrliche Spannung liegt bei N, L, 13, 14, 21, 22, 23, 24, 25 und 26
Mit dem PinTherm Connect dรผrfen nur Gerรคte gesteuert werden, die den
Sicherheitsbestimmungen der EN-IEC 61010-1 entsprechen.
PinTherm Connect
06.29.108
MO
TAG
08:01 18ยบC
X:060
OK
RESET
ESC
0
I
30
Lire attentivement ce document avant de
commencer lโ€™installation de lโ€™appareil
Avertissement
Une installation, un rรฉglage, une modi๎ƒ€cation, une rรฉparation ou un entretien mal exรฉcutรฉ(s)
peut entraรฎner des dommages matรฉriels ou des blessures. Tous les travaux doivent รชtre exรฉcutรฉs
par des professionnels reconnus et quali๎ƒ€รฉs. Lorsque lโ€™appareil nโ€™est pas installรฉ suivant les
prescriptions, la garantie รฉchoit. Cet appareil nโ€™est pas destinรฉ ร  lโ€™utilisation par des personnes (y
compris des enfants) aux capacitรฉs physiques, sensorielles ou mentales amoindries, ou manquant
dโ€™expรฉriences et de connaissances, sans surveillance ni instructions quant ร  lโ€™utilisation de
lโ€™appareil par une personne responsable de leur sรฉcuritรฉ. Il convient de surveiller les enfants a๎ƒ€n
de veiller ร  ce quโ€™ils ne jouent pas avec lโ€™appareil.
31
FR
1.0 Table des matiรจres
2.0 Gรฉnรฉralitรฉs
2.1 Modi๎ƒ€cations sous rรฉserve page 32
2.2 Avertissements gรฉnรฉraux page 32
3.0 Donnรฉes techniques
3.1 Donnรฉes techniques PinTherm Connect page 32
3.2 Donnรฉes techniques sonde ambiante externe (en option) page 33
3.3 Tableau de rรฉsistance (externe) de la sonde ambiante page 33
3.4 Rรฉglages dโ€™usine PinTherm Connect page 33
4.0 Installation
4.1 Gรฉnรฉralitรฉs page 34
4.2 Montage PinTherm Connect page 34
4.3 Montage de la sonde ambiante externe (en option) page 34
5.0 Consigne dโ€™installation
5.1 Explication des boutons poussoirs et des LEDs page 35
5.2 Explication af๎ƒ€chage page 36
5.3 Premiรจre mise en service de PinTherm Connect page 36
5.4 Activation du menu de lโ€™utilisateur page 37
5.5 Paramรฉtrer ou modi๎ƒ€er les dรฉlais de connexion page 37
5.6 Modi๎ƒ€er la tempรฉrature de jour/de nuit page 38
5.7 Modi๎ƒ€er la date et lโ€™heure page 38
5.8 Paramรจtres vacances page 38
5.9 Modi๎ƒ€er le code menu page 38
5.10 Modi๎ƒ€er le choix de la langue page 39
5.11 Calibrage page 39
5.12 Chauffage/climatisation page 39
5.13 Diffรฉrence de commutation page 40
5.14 Modi๎ƒ€er le signal dโ€™erreur minimal page 40
5.15 Modi๎ƒ€er le signal dโ€™erreur maximal page 40
5.16 Modi๎ƒ€er la plage de signal dโ€™erreur page 40
5.17 Modbus page 41
5.18 Info Ethernet page 41
5.19 Paramรจtres IP page 41
5.20 Mettre en/hors service la minuterie supplรฉmentaire page 41
5.21 Mettre en service la fonction de ramonage de cheminรฉe page 42
5.22 Retour aux paramรจtres dโ€™usine de PinTherm Connect page 42
6.0 Destruction PinTherm Connect page 42
7.0 Modbus page 42
8.0 Possibilitรฉs de raccordement de PinTherm Connect page 43
Annexe I Schรฉmas de cรขblage page 87
Annexe II Modbus page 94
32
2.0 Gรฉnรฉralitรฉs
2.1 Modi๎ƒ€cations sous rรฉserve
Le fabricant travaille sans relรขche ร  lโ€™amรฉlioration des produits et se rรฉserve le droit dโ€™apporter
des modi๎ƒ€cations dans les spรฉci๎ƒ€cations, sans avis prรฉalable. Les dรฉtails techniques sont supposรฉs
รชtre corrects mais ne constituent pas une base pour un contrat ou une garantie. Tous les ordres
sont acceptรฉs aux stipulations standard de nos conditions gรฉnรฉrales de vente et de livraison
(disponibles sur demande).
2.2 Avertissements gรฉnรฉraux
Lโ€™installation doit rรฉpondre aux prescriptions nationales et/ou rรฉgionales en vigueur. Faites dรจs
lors installer PinTherm Connect par un installateur compรฉtent et quali๎ƒ€รฉ en tentant compte de la
lรฉgislation nationale et internationale. En cas dโ€™installation, de rรฉglage, de modi๎ƒ€cation, dโ€™entretien
ou de rรฉparation erronรฉ, la garantie รฉchoit.
ร‰teignez toujours lโ€™alimentation รฉlectrique de 230V avant la connexion des terminaux. La tension
de secteur sur le PinTherm Connect doit pouvoir รชtre รฉteint dโ€™une maniรจre ร  deux pรดles au
moyen dโ€™un commutateur permanent qui est appropriรฉ pour 250VAC / 10A et respecte les
mesures de sรฉcuritรฉ applicables.
Seulsles dispositifs qui respectent EN-IEC 61010-1 peuvent รชtre opรฉrรฉs avec le PinTherm
Connect.
Nettoyez le boitier du PinTherm Connect avec un tissu humide. Nโ€™appliquez pas de solvants.
Il nโ€™y a aucune exigence quant ร  la ventilation dans le voisinage immรฉdiat du contrรดleur.
Avertissement โ€“ Risque dโ€™รฉlectrochoc
Avertissement - avertissement gรฉnรฉral, risque de danger.
Il peut y avoir une tension sur les terminaux oรน il est placรฉ.
3.0 Donnรฉes techniques
3.1 Donnรฉes techniques PinTherm Connect
โ€ข Classi๎ƒ€cation de lโ€™unitรฉ : PinTherm Connect
โ€ข Numรฉro dโ€™article : 06 29 108
โ€ข Alimentation PinTherm Connect : 90 โ€“ 240 VAC / 47-63Hz
โ€ข Consommation propre : < 9W
โ€ข Horloge : 24 heures avec passage automatique heure dโ€™รฉtรฉ / heure
dโ€™hiver
โ€ข Programmes de rรฉglage : 3 programmes par jour
โ€ข Plage de rรฉglage diffรฉrentielle : 0,1 - 3K
โ€ข Dimensions : 166 x 160 x 106mm (Lxlxh)
โ€ข Poids : 880 gramme
โ€ข Degrรฉ de protection : IP-54
โ€ข Environnement dโ€™installation : Transport/stockage: -20ยฐC ร  +70ยฐC.
Opรฉrationnel: -10ยฐC ร  +60ยฐC
Humiditรฉ relative : 0-90% sans condensation
Installation maximale ร  2000 mรจtres au dessus du niveau de la
mer.
โ€ข Catรฉgorie de surtension : 11
โ€ข Niveau de pollution : 2
!
!
33
FR
โ€ข Contact de sรฉlection* : Chauffer: 230Vac/16A (4A)
Autres: 230Vac/10A (2,5A)
โ€ข Plage de rรฉglage de tempรฉrature : 0 ร  39ยฐC par paliers de 1ยฐC
โ€ข Minuteur de prolongation : rรฉglable 1, 2 ou 3 heures (060, 120, 180)
โ€ข Calibration : rรฉglable de -3.5ยฐC ร  +3.5ยฐC
โ€ข Chauffer/refroidir : Contact rรฉversible pour le chauffage ou refroidissement
โ€ข 0-10 VDC : sortie 0-10 VDC pour le chauffage ou refroidissement
โ€ข Sonde : Sonde de tempรฉrature externe (06 29 086)
โ€ข Langue rรฉglable : NL/EN/DE/FR/PL/RO/LT
โ€ข Fusible : 6A
* Les contacts de relais sont des commutateurs fonctionnels, non des commutateurs de sรฉcuritรฉ.
3.2 Donnรฉes techniques sonde ambiante externe (en option)
โ€ข Classi๎ƒ€cation de lโ€™unitรฉ : RSTF NTC4,7K
โ€ข Numรฉro dโ€™article : 06 29 086
โ€ข Rรฉsistance : NTC 4K7
โ€ข Dimensions : 79 x 81 x 26mm (Lxlxh)
โ€ข Poids : 46 gram
โ€ข Raccordement รฉlectrique : 0.75 -1.5mmยฒ
โ€ข Degrรฉ de protection : IP-30
3.3 Tableau de rรฉsistance (externe) de la sonde ambiante
-15ยฐC -10ยฐC -5ยฐC 0ยฐC 5ยฐC 10ยฐC 15ยฐC
32.937kโ„ฆ 25.217kโ„ฆ 19.392kโ„ฆ 15.040kโ„ฆ 11.743kโ„ฆ 9.241kโ„ฆ 7.330kโ„ฆ
20ยฐC 25ยฐC 30ยฐC 35ยฐC 40ยฐC 45ยฐC 50ยฐC
5.855kโ„ฆ 4.700kโ„ฆ 3.777kโ„ฆ 3.071kโ„ฆ 2.512kโ„ฆ 2.066kโ„ฆ 1.709kโ„ฆ
3.4 Rรฉglages dโ€™usine PinTherm Connect
โ€ข Code menu : 1000
โ€ข Dรฉlais de raccordemen : LU, MA, ME, JE, VE 07:30-17:30 heure
SA, DI 00 :00-00 :00 heure
โ€ข Tempรฉrature ambiante : Tempรฉrature du jour 18ยฐC
Tempรฉrature de nuit 08ยฐC
โ€ข Calibrage : +0.0
โ€ข Diffรฉrence de commutation : 1K
โ€ข Chauffage/climatisation : Chauffage
โ€ข 0-10V plage : 1K
โ€ข 0-10V min : 0V
โ€ข 0-10V max : 10V
โ€ข Modbus : Slave ID 001
โ€ข Paramรจtres IP : Statique
34
4.0 Installation
4.1 Gรฉnรฉralitรฉs
Contrรดlez le PinTherm Connect aprรจs le dรฉballage, et si commandรฉe, la sonde ambiante externe
livrรฉe, pour voir sโ€™ils ne sont pas endommagรฉs. Contrรดlez quโ€™il sโ€™agit bien du bon type/modรจle et
de la bonne tension รฉlectrique.
4.2 Montage PinTherm Connect
Dรฉterminez un endroit adaptรฉ pour monter le PinTherm Connect. Monter le PinTherm Connect
sur une surface solide qui peut soutenir au minimum 4kg. Il est conseillรฉ de placer le Pin Therm+ ร 
une distance de ยฑ 1,5m du sol, ร  un endroit accessible.
Pour le raccordement de cรขble, veuillez seulement utiliser des raccordements de cรขble
adaptรฉs avec un rรฉducteur de tension et avec une classe de feu minimale dโ€™UL94V2. Avant le
raccordement du cรขble, contrรดlez que la tension est bien dรฉconnectรฉe. Si ce nโ€™est pas le cas, vous
devez dโ€™abord dรฉbrancher la tension avant de poursuivre. Lors de la dรฉconnexion de la tension,
de lโ€™appareil ร  raccorder, il convient de tenir รฉgalement compte du livret technique/du manuel de
commande de lโ€™appareil.
Connectez le PinTherm Connect selon l โ€˜un des diagrammes รฉlectriques fournis qui se trouvent
derriรจre ce livre technique. Pour choisir le diagramme de connexion correct, vous devez savoir
sur quel type de dispositif vous connecterez le PinTherm Connect. Pour une sรฉlection voir aussi
lโ€™Annexe I.
Quand vous utilisez un signal 0-10DC, voyez le tableau ci-dessous pour la bonne longueur et le
bon diamรจtre de cรขble.
Diamรจtre Longueur
0.8mm
2
80 mรจtres
1.0mm
2
100 mรจtres Il est conseillรฉ dโ€™utiliser ร  cet effet un cรขble blindรฉ.
1.5mm
2
150 mรจtres
4.3 Montage de la sonde ambiante externe (en option)
Placez le capteur externe sans contingent, en vue de lโ€™appareil ร  une hauteur dโ€™approximativement
1.5m du plancher. Et joignez le capteur aux terminaux appropriรฉs dans le PinTherm Connect.
Voyez le tableau ci-dessous pour la bonne longueur et le bon diamรจtre de cรขble.
Diamรจtre Longueur
0.8mm
2
80 mรจtres
1.0mm
2
100 mรจtres Il est conseillรฉ dโ€™utiliser ร  cet effet un cรขble blindรฉ.
1.5mm
2
150 mรจtres
35
FR
5.0 Consigne dโ€™installation
5.1 Explication des boutons poussoirs et des LEDs
A - Af๎ƒ€chage รฉclairรฉ (voir รฉgalement 5.2)
B - Bouton poussoir mettre en service/hors service la position de chauffage.
C - Lumiรจre LED qui sโ€™allume lorsque la fonction de chauffage est enclenchรฉe.
D - Bouton poussoir mettre en service/hors service la position de chauffage.
E - Lumiรจre LED qui sโ€™allume lorsque la fonction de ventilation est enclenchรฉe.
F - Bouton poussoir destinรฉ ร  dรฉverrouiller lโ€™appareil en cas de panne (de brรปleur).
G - La LED sโ€™allume en cas de panne (de brรปleur)
H - Bouton poussoir pour activer le menu utilisateur ou pour aller au chiffre suivant.
I - Bouton poussoir pour con๎ƒ€rmer un choix/une modi๎ƒ€cation effectuรฉ(e) ou pour aller vers
lโ€™article suivant du menu.
J - Bouton poussoir pour quitter le menu ou le paramรฉtrage sans effectuer de
modi๎ƒ€cation.
K - Bouton poussoir pour mettre en/hors service la minuterie supplรฉmentaire.
L - Bouton poussoir ๏€ต+๏€ถ โ€“ pour modi๎ƒ€er un paramรจtre.
M - La LED sโ€™allume en cas de demande de chaleur dans la position chauffage (brรปleur allumรฉ).
N - La LED sโ€™allume quand le ventilateur est enclenchรฉ.
O - La LED sโ€™allume lorsque la fonction minuterie supplรฉmentaire est enclenchรฉe.
C
OK
PinTherm Connect
06.29.108
LU
JOUR
08:01
E
G
M
N
O
D
F
J K LI
A
B
H
RESET
ESC
0
I
18ยบC
X:060
36
5.2 Explication af๎ƒ€chage
A - Indique le jour de la semaine.
B - Lโ€™heure rรฉelle de lโ€™horloge sโ€™af๎ƒ€che ici.
C - Donne la tempรฉrature mesurรฉe (ยฐC).
D - Indique le nombre de minutes avant que la fonction de minuterie supplรฉmentaire ne soit
mise hors service et que le Pin Therm+ passe de nouveau sur la tempรฉrature de nuit.
E - Indique si le PinTherm Connect est en position de jour (JOUR) ou en position de nuit
(NUIT) et rรฉgule sur la base de la tempรฉrature de jour ou de nuit.
5.3 Premiรจre mise en service de PinTherm Connect
Quand vous mettez le PinTherm Connect sous tension pour la premiรจre fois, il vous sera de-
mandรฉ de sรฉlectionner la langue souhaitรฉe (choix de langue : NL, EN, DE, FR, PL, RO, LT), ens-
uite, vous devez rรฉgler la date et lโ€™heure. Ensuite, PinTherm Connect retourne ร  lโ€™รฉcran principal.
Langues au choix : NL, EN, DE, FR, PL, RO, LT
C
LU
JOUR
08:01
E
D
B
A
18ยบC
X:060
SELECT LANGUAGE SA 01-01-2006
00:00:00
16ยฐCLU
JOUR
08:00
modi๎€›er la valeur
qui clignote
passer au chi๎€‹re suivant
sรฉlectionnez la
langue dรฉsirรฉe
OK OK
ENGLISH
37
FR
5.4 Activation du menu de lโ€™utilisateur
Dans le menu, vous pouvez modi๎ƒ€er les paramรฉtrages suivants:
โ€“ Saisir/modi๎ƒ€er les dรฉlais de raccordement
โ€“ Modi๎ƒ€er la tempรฉrature de jour/nuit
โ€“ Modi๎ƒ€er lโ€™heure/la date
โ€“ Paramรจtres vacances
โ€“ Modi๎ƒ€er le code menu
โ€“ Modi๎ƒ€er le choix de la langue
โ€“ Calibrage
โ€“ 0-10V min 0-5V
โ€“ 0-10V max 5-10V
โ€“ 0-10V range (1-3)
โ€“ Modbus
โ€“ Paramรจtres IP
5.5 Paramรฉtrer ou modi๎ƒ€er les dรฉlais de connexion
INTRODUIRE CODE
quitter le menu et revenir ร 
l'รฉcran principal
Le code de menu est
rรฉglรฉ par dรฉfaut sur
1000
ยฐCLU
JOUR
08:01
modifier la valeur qui
clignote
passer au chiffre suivant
sรฉlectionner le menu
correspondant
ESC
OK OK
0000
RENTRER/CHANCER
HEURES COMMUNAT
LUNDI
etc
revenir au
menu
modifier la valeur
qui clignote
passer au chiffre suivant
OK
OK
OK
07:30 -> 17:00
RENTRER/CHANGER
HEURES COMMUNAT
LUNDI
OK
--:-- -> --:--
modifier la valeur
qui clignote
passer au chiffre suivant
OK
12
LUNDI
--:-- -> --:--
3 MARDI
07:30 -> 17:00
1 DIMANCHE
--:-- -> --:--
3
38
5.6 Modi๎ƒ€er la tempรฉrature de jour/de nuit
5.7 Modi๎ƒ€er la date et lโ€™heure
5.8 Paramรจtres de vacances
Pendant le bloc de temps, le contrรดle se rรฉglera selon la tempรฉrature de nuit.
5.9 Modi๎ƒ€er le code menu
VACANCES ACTIF
ON
revenir au
menu
sรฉlectionner
selectionner on ou off
(allumรฉ/รฉteind)
OK OK
PROGRAMMATION
VACANCES
DU: 01-07-2017
AU: 01-08-2017
OK
modifier la valeur
qui clignote
passer au
chiffre suivant
18ยฐC
TEMPERATURE JOUR
TEMPERATURE NUIT
sรฉlectionner
revenir au
menu
modifier la valeur
qui clignote
passer au chiffre suivant
modifier la valeur
qui clignote
passer au chiffre suivant
OK OK
OK
08ยฐC
TEMPERATURE
SOUHAITEE
LU 23-03-2009
09:10:00
revenir au
menu
sรฉlectionner
modifier la valeur
qui clignote
passer au chiffre suivant
OK OK
MODIFIER
HEURE/DATE
1000
MODIFIER
CODE MENU
CHOISIR CODE
Nouveau code de menu
revenir au
menu
sรฉlectionner
modifier la valeur
qui clignote
passer au chiffre suivant
OK OK
39
FR
5.10 Modi๎ƒ€er le choix de la langue
Langues au choix : NL, EN, DE, FR, PL, RO, LT.
5.11 Calibrage
En cas dโ€™emplacement de montage dรฉfavorable du PinTherm Connect, on peut assister ร  une di-
vergence par rapport ร  la tempรฉrature rรฉellement mesurรฉe parle PinTherm Connect. La fonction
de calibrage de la tempรฉrature permet de compenser cet รฉcart de tempรฉrature via la saisie dโ€™une
valeur de correction. Quand ce nโ€™est pas suf๎ƒ€sant, vous pouvez รฉgalement choisir de raccorder
une sonde ambiante externe au PinTherm Connect.
Exemple: La tempรฉrature mesurรฉe atteint 18 ยฐC, lโ€™รฉcran sur le PinTherm Connect af๎ƒ€che 20 ยฐC.
La diffรฉrence atteint donc dans cet exemple 2 ยฐC de trop la valeur de correction doit
alors รชtre rรฉglรฉe sur -2 ยฐC.
5.12 Chauffage/climatisation
Rรฉglez pour que le contrรดleur soit prรชt pour contrรดler le chauffage ou la climatisation.
CHAUF./REFROIDIR
CHAUFFER
revenir au
menu
sรฉlectionner
modifier le paramรจtre
OK
CHAUF./REFROIDIR
OK
FRANCAIS
CHOIX LANGUE
revenir au
menu
sรฉlectionnez la
langue dรฉsirรฉe
sรฉlectionner
OK OK
MODIFIER LANGUE
CALIBRAGE TEMP. CALIBRAGE TEMP.
Valeur de correction est rรฉglable
revenir au
menu
sรฉlectionner
modifier la valeur
qui clignote
passer au chiffre suivant
OK OK
+ 0.0ยฐC
de -3,5ยฐC jusqu'ร  +3,5ยฐC
40
5.13 Diffรฉrence de commutation
Rรฉglable entre 0,1 et 3,0 K.
5.14 Modi๎ƒ€er le signal dโ€™erreur minimal
Remarque :
En lโ€™absence de demande de chaleur, le PinTherm Connect va รฉmettre 0Vdc.
5.15 Modi๎ƒ€er le signal dโ€™erreur maximal
5.16 Modi๎ƒ€er la plage de signal dโ€™erreur
Cette fonction permet de dรฉterminรฉ quand le signal 0-10 Vdc est modulรฉ pendant la demande de
chaleur. Quand ce dernier est rรฉglรฉ sur 1,0, le PinTherm Connect 1K va remoduler le signal 0-10
V en dessous de la tempรฉrature souhaitรฉe.
La plage est rรฉglable de 0,5 -3,0 et est rรฉglรฉe dโ€™usine sur 1,0.
DIFF. D'ECHANGE
1.0K
revenir au
menu
sรฉlectionner
modifier la valeur
qui clignote
OK
DIFF. D'ECHANGE
OK
modifier le paramรจtre
OK OK
0-10V min(0-5V)
2.0 V
0-10V min(0-5V)
retour au
menu
sรฉlectionnez
OK OK
0-10V max(5-10V)
10.0 V
0-10V max(5-10V)
modifier le paramรจtre
retour au
menu
sรฉlectionnez
OK OK
0-10V Range(1-3)
1.0
0-10V Range(1-3)
modifier le paramรจtre
retour au
menu
sรฉlectionnez
41
FR
5.17 ModBus
Slave ID : rรฉglable 1-247
Paramรจtres par dรฉfaut: 1
5.18 Info Ethernet
Af๎ƒ€chage Adresse IP
5.19 Paramรจtres IP
DHCP- affectation automatique Adresse IP
Statique : Adresse IP ๎ƒ€xe
SUBnet Mask
5.20 Mettre en/hors service la minuterie supplรฉmentaire
Cette fonction permet, en dehors des dรฉlais de raccordement paramรฉtrรฉs, de faire passer manuel-
lement 1, 2 ou 3 heures vers la tempรฉrature jour.
La LED jaune avec le symbole va sโ€™allumer quand cette fonction est enclenchรฉe. Dans la partie
infรฉrieure droite de lโ€™af๎ƒ€chage, le temps restant, en minutes, sera af๎ƒ€chรฉ avant que la fonction se
mette de nouveau hors service et que le PinTherm Connect fonctionne de nouveau sur la tem-
pรฉrature nuit. Entre-temps, la fonction peut de nouveau รชtre mise hors service en appuyant en-
core une fois sur le bouton poussoir jusquโ€™ร  ce que la LED jaune sโ€™รฉteigne et que le nombre de
ADRESSE IP
192.168.001.100
revenir au
menu
sรฉlectionner
OK OK
INFO ETHERNET
ADRESSE MAC
5410EC220037
OK
MODE IP
STATIQUE
revenir au
menu
sรฉlectionner
OK OK
ADRESSE IP
ADDRESS IP
192.168.001.100
OK
modifier le paramรจtre
modifier la valeur
qui clignote
aller au
valeur suivant
MASK SUBNET
255.255.255.000
modifier la valeur
qui clignote
aller au
valeur suivant
MODBUS INST.
001
revenir au
menu
sรฉlectionner
modifier la valeur
qui clignote
OK
MODBUS
OK
aller au
valeur suivant
42
minutes ne sโ€™af๎ƒ€che plus ร  lโ€™รฉcran. Voir lโ€™illustration ci-dessous.
5.21 Mettre en service la fonction de ramonage de cheminรฉe
Cette fonction permet de faire chauffer lโ€™appareil temporairement ร  pleine charge/charge partielle
pour pouvoir effectuer des mesures, vous trouverez ci-dessous comment vous pouvez mettre en/
hors service cette fonction. Aprรจs la mise en service, cette fonction reste active pendant 15 minu-
tes et sera ensuite automatiquement mise hors service.
5.22 Retour aux paramรจtres dโ€™usine de PinTherm Connect
Si vous appliquez cette fonction, tous les paramรจtres dโ€™usine sont rรฉinstallรฉs. Cette fonction peut
toujours รชtre utilisรฉe. Voir lโ€™illustration ci-dessous.
6.0 Destruction PinTherm Connect
Quand le PinTherm Connect est remplacรฉ ou รฉliminรฉ, il convient de le faire recycler ou รฉliminer
conformรฉment aux rรจglements nationaux et/ou locaux.
7.0 Modbus
- Communication [12]
- Modbus-liste [13]
NUIT
LU
X:060
18ยฐC
LU
JOUR
17:01
X:120
LU
JOUR
17:01
X:180
LU
JOUR
17:01
17:01
18ยฐC
18ยฐC
18ยฐC
De cette maniรจre, vous mettez ๎€žn ร  la fonction
et vous revenez ร  lโ€™รฉcran principal.
ESC
0-10V
10V
14:59
Appuyez pour augmenter la tension (max. 10 V)
Utilisez les boutons poussoirs ci-dessous pour faire fonctionner
lโ€™appareil ร  une tension infรฉrieure (tension partielle).
appuyez pour abaisser la tension
ยฑmaintenir enfoncรฉ
pendant ยฑ12 sec.
0
maintenez ce
bouton enfoncรฉ
pendant environ
12 s.
SELECT LANGUAGE
16ยฐCLU
JOUR
08:01
cette opรฉration vous permet
de revenir ร  l'รฉcran principal
Les valeurs dรฉfinies en usine
ne seront pas modifiรฉes!
OK OK
ESC
ENGLISH
REGLAGES USINE
RESTAURES!
RETOUR EN
REGLAGES USINE?
43
FR
8.0 Possibilitรฉs de raccordement de PinTherm Connect
L N Bornes de connexion (230Vac/50Hz)
21 - 22 Ventilation continue
21 - 23 Chauffage/climatisation
24 - 25 Lampe de panne
25 - 26 Rรฉinitialisation contact
+ - 0-10Vdc (Chauffage/climatisation)
11 - 12 Capteur externe
A - B MODBUS RTU (R ground)
RJ 45 connector Internet / Modbus TCP/IP
13 - 14 Ventilateur externe de contact
Avertissement: Prรฉsence dโ€™une tension dangereuse sur N, L, 13, 14, 21, 22, 23, 24, 25 et 26
Avec le PinTherm Connect, seuls les dispositifs respectant les mesures de sรฉcuritรฉ ๎ƒ€xรฉes dans
EN-IEC 61010-1 peuvent รชtre contrรดlรฉs.
PinTherm Connect
06.29.108
LU
JOUR
08:01 18ยบC
X:060
OK
RESET
ESC
0
I
44
Lees dit document door voordat u begint
met de installatie en ingebruikname
Waarschuwing!
Een foutief uitgevoerde installatie, wijziging of reparatie kan leiden tot materiรซle schade of
verwondingen. Alle werkzaamheden moeten door erkende, gekwali๎ƒ€ceerde vakmensen worden
uitgevoerd. Indien het toestel niet volgens voorschrift wordt geplaatst, vervalt de garantie. Dit
apparaat is niet bedoeld voor gebruik door personen (inclusief kinderen) met verminderde
lichamelijke, zintuiglijke of geestelijke vermogens, of gebrek aan ervaring en kennis, tenzij zij
onder toezicht staan of worden geรฏnstrueerd over het gebruik van het apparaat door een
persoon die verantwoordelijk is voor hun veiligheid. Kinderen moeten gecontroleerd worden
om ervoor te zorgen dat ze niet met het apparaat spelen.
45
NL
1.0 Inhoudsopgave
2.0 Algemeen
2.1 Wijzigingen voorbehouden pag. 46
2.2 Algemene waarschuwingen pag. 46
3.0 Technische gegevens
3.1 Technische gegevens PinTherm Connect pag. 46
3.2 Technische gegevens externe ruimtesensor (optioneel) pag. 47
3.3 Weerstandstabel externe ruimtesensor (optioneel) pag. 47
3.4 Fabrieksinstellingen PinTherm Connect pag. 47
4.0 Installatie
4.1 Algemeen pag. 48
4.2 Montage PinTherm Connect pag. 48
4.3 Montage externe ruimtesensor pag. 48
5.0 Bedieningshandleiding
5.1 Verklaring drukknoppen en led`s pag. 49
5.2 Verklaring display pag. 50
5.3 Eerste ingebruikname van de PinTherm Connect pag. 50
5.4 Activeren van het gebruikersmenu pag. 51
5.5 Schakeltijden ingeven of wijzigen pag. 51
5.6 Dag-/nachttemperatuur wijzigen pag. 52
5.7 Tijd en datum wijzigen pag. 52
5.8 Vakantieregeling instellen pag. 52
5.9 Menu code wijzigen pag. 52
5.10 Taalkeuze wijzigen pag. 53
5.11 IJking pag. 53
5.12 Verwarmen/koelen pag. 53
5.13 Schakeldifferentie pag. 54
5.14 Minimum regelsignaal wijzigen pag. 54
5.15 Maximum regelsignaal wijzigen pag. 54
5.16 Range regelsignaal wijzigen pag. 54
5.17 ModBus pag. 55
5.18 Ethernet Info pag. 55
5.19 IP-instellingen pag. 55
5.20 Overwerktimer in- /uitschakelen pag. 55
5.21 Schoorsteenvegerfunctie inschakelen pag. 56
5.22 Terugplaatsen fabrieksinstellingen PinTherm Connect pag. 56
6.0 Afdanken PinTherm Connect pag. 56
7.0 Modbus pag. 56
8.0 Aansluitmogelijkheden PinTherm Connect pag. 57
Bijlage I Aansluitschemaโ€™s pag. 87
Bijlage II Modbus pag. 94
46
2.0 Algemeen
2.1 Wijzigingen voorbehouden
De fabrikant streeft continu naar verbetering van haar producten en behoudt zich het recht
voor om zonder voorafgaande kennisgeving veranderingen in de speci๎ƒ€caties aan te brengen. De
technische details worden als correct verondersteld maar vormen geen basis voor een contract
of garantie. Alle orders worden geaccepteerd onder de standaard condities van onze algemene
verkoop- en leveringsvoorwaarden (op aanvraag leverbaar).
2.2 Algemene waarschuwingen
De installatie moet voldoen aan de geldende plaatselijke en/of landelijke voorschriften. Laat
daarom de PinTherm Connect door een vakbekwaam en gekwali๎ƒ€ceerd installateur installeren
met inachtneming van de nationale en internationale regelgeving. Bij een foutieve installatie,
afregeling, wijziging, onderhoudsafhandeling of herstelling vervalt de garantie.
Schakel altijd de 230V voeding uit voordat er aan de terminals/aansluitklemmen geschroefd wordt.
De netspanning op de PinTherm Connect moet dubbelpolig uitschakelbaar zijn middels een
permanent aanwezige schakelaar welke geschikt is voor 250VAC/10A en voldoet aan de geldende
veiligheidsvoorschriften.
Met de PinTherm Connect mogen alleen toestellen aangestuurd worden die voldoen aan EN-IEC
61010-1.
Reinig de behuizing van de PinTherm Connect met een vochtige doek. Geen oplosmiddelen
toepassen.
Er zijn geen eisen met betrekking tot de ventilatie in de directe omgeving van de regelaar.
Waarschuwing - risico op elektrische schok.
Waarschuwing - algemeen waarschuwing, kans op gevaar.
Op de aansluitklemmen waarbij een is geplaats kan netspanning staan.
3.0 Technisch gegevens
3.1 Technische gegevens PinTherm Connect
โ€ข Type aanduiding : PinTherm Connect
โ€ข Artikelnummer : 06 29 108
โ€ข Voeding PinTherm Connect : 90 โ€“ 240 VAC / 47-63Hz
โ€ข Eigen verbruik : < 9W
โ€ข Klok : 24uurs klok met automatische zomer/wintertijd omschakeling
โ€ข Schakelprogrammaโ€™s : 3 schakelprogrammaโ€™s per dag
โ€ข Schakeldifferentie : 0,1 - 3K
โ€ข Afmeting : 166 x 160 x 106mm (lxbxh)
โ€ข Gewicht : 880 gram
โ€ข Beschermingsgraad : IP-54
โ€ข Installatie omgeving : Transport/opslag: -20ยฐC tot +70ยฐC.
Operationeel: -10ยฐC tot +60ยฐC
Relatieve luchtvochtigheid: 0-90% niet condenserend
Installatie maximaal 2000 meter boven zeeniveau.
โ€ข Overspanningscategorie : 11
โ€ข Pollutiegraad : 2
!
!
NL
47
โ€ข Schakelcontact(en)* : Verwarmen: 230Vac/16A (4A)
Overige: 230Vac/10A (2,5A)
โ€ข Temperatuurinstelling : 0 tot 39ยฐC per 1ยฐC instelbaar
โ€ข Overwerktimer : instelbaar 1, 2 of 3 uur (060, 120, 180)
โ€ข IJking : instelbaar van -3.5ยฐC tot +3.5ยฐC
โ€ข Verwarmen/koelen : Omkeerbaar contact t.b.v. verwarmen of koelen
โ€ข 0-10 VDC : 0-10 VDC output t.b.v. verwarmen of koelen
โ€ข Sensor : externe ruimtesensor (06 29 086)
โ€ข Instelbare talen : NL/EN/DE/FR/PL/RO/LT
โ€ข Voorzekering : 6A
* De relais contacten zijn functionele schakelaars, geen veiligheidsschakelaars.
3.2 Technische gegevens externe ruimtesensor (optioneel)
โ€ข Type aanduiding : RSTF NTC4,7K
โ€ข Artikelnummer : 06 29 086
โ€ข Weerstand : NTC 4K7
โ€ข Afmeting : 79 x 81 x 26mm (lxbxh)
โ€ข Gewicht : 46 gram
โ€ข Elektrische aansluiting : 0.75 -1.5mmยฒ
โ€ข Beschermingsgraad : IP-30
3.3 Weerstandstabel externe ruimtesensor (optioneel)
-15ยฐC -10ยฐC -5ยฐC 0ยฐC 5ยฐC 10ยฐC 15ยฐC
32.937kโ„ฆ 25.217kโ„ฆ 19.392kโ„ฆ 15.040kโ„ฆ 11.743kโ„ฆ 9.241kโ„ฆ 7.330kโ„ฆ
20ยฐC 25ยฐC 30ยฐC 35ยฐC 40ยฐC 45ยฐC 50ยฐC
5.855kโ„ฆ 4.700kโ„ฆ 3.777kโ„ฆ 3.071kโ„ฆ 2.512kโ„ฆ 2.066kโ„ฆ 1.709kโ„ฆ
3.4 Fabrieksinstellingen PinTherm Connect
โ€ข Menu code : 1000
โ€ข Schakeltijden : MA, DI, WO, DO, VR 07:30-17:30 uur
ZA, ZO 00:00-00:00 uur
โ€ข Ruimtetemperatuur : Dagtemperatuur 18ยฐC
Nachttemperatuur 08ยฐC
โ€ข IJking : +0.0
โ€ข Schakeldifferentie : 1K
โ€ข Verwarmen/koelen : Verwarmen
โ€ข 0-10V range : 1K
โ€ข 0-10V min : 0V
โ€ข 0-10V max : 10V
โ€ข Modbus : Slave ID 001
โ€ข IP-instelling : statisch
48
4.0 Installatie
4.1 Algemeen
Controleer na het uitpakken de PinTherm Connect en meegeleverde externe voeler op
beschadiging. Controleer op juistheid van het type/model en de elektrische spanning.
4.2 Montage PinTherm Connect
Bepaal een geschikte plaats om de PinTherm Connect te monteren. Bevestig de PinTherm
Connect op een stevige ondergrond, die minimaal 4kg kan dragen. Geadviseerd wordt om de
PinTherm Connect op een afstand van ยฑ1.5m vanaf de vloer te plaatsen, op een goed bereikbare
plaats.
Pas ten behoeve van de kabeldoorvoer kabelwartels toe voorzien van trekontlasting, met
een minimale brandklasse van UL94V2. Controleer voor het aansluiten van de bekabeling of
de spanning is uitgeschakeld. Indien dit niet het geval is dient eerst de spanning te worden
uitgeschakeld voordat u verder gaat. Bij het uitschakelen van de spanning, van het aan te sluiten
toestel, dient hierbij ook het technisch boek/bedieningshandleiding van het toestel in acht te
worden genomen.
Sluit de PinTherm Connect aan volgens een van de meegeleverde elektrische schemaโ€™s welke
achterin dit technisch boek staan. Om het juiste aansluitschema te selecteren moet u weten op
welk type toestel u de PinTherm Connect gaat aansluiten. Voor een selectie zie ook bijlage I.
Bij het toepassen van een 0-10VDC signaal, zie de tabel hieronder voor de juiste kabeldiameter en
bijbehorende lengte.
Diameter Lengte
0.8mm
2
80 meter
1.0mm
2
100 meter Geadviseerd wordt om hiervoor een afgeschermde
1.5mm
2
150 meter kabel te gebruiken
4.3 Montage externe ruimtesensor
Plaats de externe ruimtesensor tochtvrij, in het zicht van het toestel op een hoogte van ca.
1.5m vanaf de vloer. En sluit de voeler aan op de daarvoor bestemde klemmen in de PinTherm
Connect. Zie onderstaande tabel voor de juiste kabeldiameter.
Diameter Lengte
0.8mm
2
80 meter
1.0mm
2
100 meter Geadviseerd wordt om hiervoor een afgeschermde
1.5mm
2
150 meter kabel te gebruiken.
NL
49
5.0 Bedieningshandleiding
5.1 Verklaring drukknoppen en led`s.
A - Verlichte display (zie ook 5.2)
B - Drukknop om de stand verwarmen in of uit te schakelen.
C - Led licht op als de functie verwarmen is ingeschakeld.
D - Drukknop om het continue draaien van de ventilator in of uit te schakelen.
E - Led licht op als de functie continue ventileren is ingeschakeld.
F - Drukknop om in geval van een (brander)storing het toestel te ontgrendelen.
G - Led brand in geval van (brander)storing.
H - Drukknop om het gebruikersmenu te activeren of om naar het volgende cijfer te gaan.
I - Drukknop om een gemaakte keuze/wijziging te bevestigen of om naar het volgende menu
item te gaan.
J - Drukknop om het menu of de instelling te verlaten zonder een wijziging uit te voeren.
K - Drukknop om de overwerktimer in of uit te schakelen.
L - Drukknop ๏€ต+๏€ถ โ€“ om een instelling te wijzigen.
M - Led licht op bij warmtevraag in de stand verwarmen (brander in).
N - Led licht op wanneer de ventilator continue draait.
O - Led licht op als de functie overwerktimer is ingeschakeld.
C
OK
PinTherm Connect
06.29.108
MA
DAG
08:01
E
G
M
N
O
D
F
J K LI
A
B
H
RESET
ESC
0
I
18ยบC
X:060
50
5.2 Verklaring display
A - Geeft de dag van de week weer.
B - De actuele kloktijd wordt hier weergegeven.
C - Geeft de gemeten temperatuur (ยฐC) aan.
D - Geeft het aantal minuten aan voordat de functie overwerktimer weer wordt uitgeschakeld
en de PinTherm Connect weer op de nachttemperatuur gaat regelen.
E - Geeft aan of de PinTherm Connect in de dagstand (DAG) of in de nachtstand (NACHT)
staat en regelt op basis van de dag- of nachttemperatuur.
5.3 Eerste ingebruikname van de PinTherm Connect
Wanneer u voor de eerste keer spanning op de PinTherm Connect zet zal u worden gevraagd om
de gewenste taal te selecteren, (instelbare talen: NL, EN, DE, FR, PL, RO, LT), en vervolgens de
tijd en datum in te stellen. Hierna keert de PinTherm Connect terug naar het hoofdscherm.
Instelbare talen: NL, EN, DE, FR, PL, RO, LT
๏€ ๏€‚ ๏€ƒ ๏€„ ๏€… ๏€† ๏€‡ ๏€ˆ ๏€‰ ๏€Š ๏€‚๏€ ๏€‚๏€‚ ๏€‚๏€ƒ ๏€‚๏€„ ๏€‚๏€… ๏€‚๏€† ๏€‚๏€‡ ๏€‚๏€ˆ ๏€‚๏€‰ ๏€‚๏€Š
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€๏€‘๏€Ž๏€”๏€•๏€๏€Ž๏€–๏€•๏€Ž๏€Ž๏€
๏€—๏€Œ๏€‘๏€•๏€˜๏€๏€๏€“๏€’๏€‘๏€๏€™๏€๏€๏€š๏€›๏€‘๏€™๏€”
๏€๏€œ๏€๏€ž
๏€๏€œ๏€Ÿ๏€ž
๏€›๏€ ๏€ก๏€œ๏€œ๏€ข๏€ฃ๏€ค๏€ฅ๏€ฆ๏€’๏€ณ๏€Ÿ๏€จ๏€œ๏€ฉ๏€ช๏€’๏€๏€‡๏€ƒ๏€Š๏€๏€Š๏€ƒ
๏€™๏€ซ๏€๏€ญ๏€ช
๏€‘๏€ฎ๏€ฉ๏€ช
๏€„๏€ฏ๏€‚๏€‚๏€ฏ๏€ƒ๏€๏€‚๏€‡
๏€”๏€Ÿ๏€จ๏€œ๏€ช๏€ซ๏€’
๏€ฅ๏€ญ๏€ช๏€ช๏€œ๏€ฉ
๏€๏€ฉ๏€ฎ๏€œ๏€ฐ
๏€›๏€ฉ๏€๏€ž๏€ฅ๏€ฉ
๏€•๏€˜ ๏€•๏€ฑ๏€ฐ๏€œ
๏€ฒ๏€œ๏€ฉ๏€ณ๏€ค๏€œ
๏€™๏€ด๏€–๏€ฏ๏€๏€‡๏€ƒ๏€Š๏€๏€Š๏€ƒ๏€ฏ๏€‘๏€š
๏€—๏€ค๏€ฅ๏€๏€จ๏€œ๏€ฉ๏€ช
๏€‚๏€ž๏€
๏€‚๏€…
๏€†๏€‚
๏€†๏€
๏€ต๏€’๏€’๏€ข๏€’๏€’๏€ค๏€’๏€’๏€ช๏€’๏€’๏€ซ๏€’๏€’๏€ซ๏€’๏€’๏€๏€’๏€’๏€๏€’๏€’๏€œ๏€’๏€’๏€Ÿ๏€’๏€’๏€จ๏€’๏€’๏€ฅ๏€’๏€’๏€ค๏€’๏€’๏€œ๏€’๏€’๏€ต
๏€
๏€๏€๏€‘๏€๏€Ž๏€’๏€Œ๏€‘๏€‚๏€“๏€„๏€”๏€‚๏€„๏€ ๏€•๏€‚ ๏€…๏€ˆ๏€–๏€…๏€ˆ๏€–๏€—๏€…๏€…๏€‹
๏€…๏€…๏€‡๏€…๏€…๏€‡๏€…๏€…
๏€Œ๏€๏€Ž๏€๏€‚
๏€ƒ๏€‚๏€„
๏€…๏€†๏€‡๏€…๏€… ๏€Œ๏€ˆ๏€‹
๏€บ๏€ค๏€ป๏€ผ๏€ค๏€ฆ๏€๏€’๏€จ๏€œ๏€
๏€ต๏€ฅ๏€ค๏€ฐ๏€ฐ๏€œ๏€ฉ๏€œ๏€ฅ๏€ฃ๏€œ๏€’๏€Ÿ๏€ค๏€ป๏€ ๏€œ๏€ฉ
๏€ฅ๏€ซ๏€ซ๏€ฉ๏€’๏€จ๏€œ๏€๏€’๏€ฝ๏€ฎ๏€ข๏€ฆ๏€œ๏€ฅ๏€ฃ๏€œ
๏€Ÿ๏€ค๏€ป๏€ ๏€œ๏€ฉ๏€’๏€ฆ๏€ซ๏€ซ๏€ฅ
๏€ฆ๏€œ๏€บ๏€œ๏€ฅ๏€ณ๏€๏€œ๏€’๏€๏€ซ๏€ซ๏€ข
๏€ณ๏€œ๏€ข๏€œ๏€Ÿ๏€๏€œ๏€ฉ๏€œ๏€ฅ
๏€๏€‚ ๏€๏€‚
๏€๏€“๏€„๏€‘๏€˜๏€๏€™
C
MO
DAY
08:01
E
D
B
A
18ยบC
X:060
NL
51
5.4 Activeren van het gebruikersmenu
In het menu kunt u de volgende instellingen wijzigen:
โ€“ Schakeltijden ingeven/wijzigen
โ€“ Dag-/Nachttemperatuur wijzigen
โ€“ Tijd/datum wijzigen
โ€“ Vakantieregeling
โ€“ Menu code wijzigen
โ€“ Taalkeuze wijzigen
โ€“ IJking
โ€“ 0-10V min 0-5V
โ€“ 0-10V max 5-10V
โ€“ 0-10V range (1-3)
โ€“ Modbus
โ€“ IP-instelling
5.5 Schakeltijden ingeven of wijzigen
๏€ ๏€‚ ๏€ƒ ๏€„ ๏€… ๏€† ๏€‡ ๏€ˆ ๏€‰ ๏€Š ๏€‚๏€ ๏€‚๏€‚ ๏€‚๏€ƒ ๏€‚๏€„ ๏€‚๏€… ๏€‚๏€† ๏€‚๏€‡ ๏€‚๏€ˆ ๏€‚๏€‰ ๏€‚๏€Š
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€๏€‘๏€Ž๏€”๏€•๏€๏€Ž๏€–๏€•๏€Ž๏€Ž๏€
๏€—๏€Œ๏€‘๏€•๏€˜๏€๏€๏€“๏€’๏€‘๏€๏€™๏€๏€๏€š๏€›๏€‘๏€™๏€”
๏€๏€œ๏€๏€ž
๏€๏€œ๏€Ÿ๏€ž
๏€›๏€ ๏€ก๏€œ๏€œ๏€ข๏€ฃ๏€ค๏€ฅ๏€ฆ๏€’๏€ณ๏€Ÿ๏€จ๏€œ๏€ฉ๏€ช๏€’๏€๏€‡๏€ƒ๏€Š๏€๏€Š๏€ƒ
๏€™๏€ซ๏€๏€ญ๏€ช
๏€‘๏€ฎ๏€ฉ๏€ช
๏€„๏€ฏ๏€‚๏€‚๏€ฏ๏€ƒ๏€๏€‚๏€‡
๏€”๏€Ÿ๏€จ๏€œ๏€ช๏€ซ๏€’
๏€ฅ๏€ญ๏€ช๏€ช๏€œ๏€ฉ
๏€๏€ฉ๏€ฎ๏€œ๏€ฐ
๏€›๏€ฉ๏€๏€ž๏€ฅ๏€ฉ
๏€•๏€˜ ๏€•๏€ฑ๏€ฐ๏€œ
๏€ฒ๏€œ๏€ฉ๏€ณ๏€ค๏€œ
๏€™๏€ด๏€–๏€ฏ๏€๏€‡๏€ƒ๏€Š๏€๏€Š๏€ƒ๏€ฏ๏€‘๏€š
๏€—๏€ค๏€ฅ๏€๏€จ๏€œ๏€ฉ๏€ช
๏€‚๏€ž๏€
๏€†๏€
๏€†๏€ƒ
๏€†๏€‚
๏€ต๏€’๏€’๏€ข๏€’๏€’๏€ค๏€’๏€’๏€ช๏€’๏€’๏€ซ๏€’๏€’๏€ซ๏€’๏€’๏€๏€’๏€’๏€๏€’๏€’๏€œ๏€’๏€’๏€Ÿ๏€’๏€’๏€จ๏€’๏€’๏€ฅ๏€’๏€’๏€ค๏€’๏€’๏€œ๏€’๏€’๏€ต
๏€
๏€š๏€›๏€๏€œ๏€Œ๏€Ž๏€›๏€ƒ๏€๏€Œ๏€˜๏€“
๏€ฝ๏€œ๏€ฉ๏€ข๏€ซ๏€ซ๏€๏€’๏€จ๏€œ๏€๏€’๏€ช๏€œ๏€ฅ๏€ญ๏€’๏€œ๏€ฅ๏€’๏€ต๏€œ๏€œ๏€ฉ
๏€๏€œ๏€ฉ๏€ญ๏€ฆ๏€’๏€ฅ๏€ซ๏€ซ๏€ฉ๏€’๏€จ๏€œ๏€๏€’๏€จ๏€ฎ๏€ฎ๏€ ๏€ฃ๏€ณ๏€Ÿ๏€จ๏€œ๏€ฉ๏€ช
๏€Š๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€Ž๏€’๏€‘๏€“๏€๏€”๏€”๏€Ž๏€’๏€•
๏€–๏€๏€’๏€—๏€˜๏€™๏€š๏€›๏€
๏€œ๏€ˆ๏€ˆ๏€ˆ
๏€Œ๏€๏€Ž๏€๏€‚
๏€ƒ๏€‚๏€„
๏€…๏€†๏€‡๏€…๏€ˆ ๏€Œ๏€ˆ๏€‹
๏€บ๏€ค๏€ป๏€ผ๏€ค๏€ฆ๏€๏€’๏€จ๏€œ๏€
๏€ต๏€ฅ๏€ค๏€ฐ๏€ฐ๏€œ๏€ฉ๏€œ๏€ฅ๏€ฃ๏€œ๏€’๏€Ÿ๏€ค๏€ป๏€ ๏€œ๏€ฉ
๏€ฅ๏€ซ๏€ซ๏€ฉ๏€’๏€จ๏€œ๏€๏€’๏€ฝ๏€ฎ๏€ข๏€ฆ๏€œ๏€ฅ๏€ฃ๏€œ
๏€Ÿ๏€ค๏€ป๏€ ๏€œ๏€ฉ๏€’๏€ฆ๏€ซ๏€ซ๏€ฅ
๏€ช๏€ซ๏€ซ๏€ต๏€’๏€ฃ๏€œ๏€’๏€ฆ๏€œ๏€บ๏€œ๏€ฅ๏€ณ๏€๏€œ
๏€ช๏€œ๏€ฅ๏€ญ๏€ต๏€œ๏€ญ๏€ผ๏€œ
๏€„๏€…๏€‡
๏€๏€‚ ๏€๏€‚
๏€…๏€…๏€…๏€…
๏€๏€Ž๏€™๏€‚๏€‰๏€๏€‘๏€’๏€˜๏€๏€ƒ๏€๏€“
๏€˜๏€“๏€„๏€๏€š๏€๏€“๏€ž๏€Ÿ๏€˜๏€๏€•๏€˜๏€„๏€๏€“
๏€ ๏€‚ ๏€ƒ ๏€„ ๏€… ๏€† ๏€‡ ๏€ˆ ๏€‰ ๏€Š ๏€‚๏€ ๏€‚๏€‚ ๏€‚๏€ƒ ๏€‚๏€„ ๏€‚๏€… ๏€‚๏€† ๏€‚๏€‡ ๏€‚๏€ˆ ๏€‚๏€‰ ๏€‚๏€Š
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€๏€‘๏€Ž๏€”๏€•๏€๏€Ž๏€–๏€•๏€Ž๏€Ž๏€
๏€—๏€Œ๏€‘๏€•๏€˜๏€๏€๏€“๏€’๏€‘๏€๏€™๏€๏€๏€š๏€›๏€‘๏€™๏€”
๏€๏€œ๏€๏€ž
๏€๏€œ๏€Ÿ๏€ž
๏€›๏€ ๏€ก๏€œ๏€œ๏€ข๏€ฃ๏€ค๏€ฅ๏€ฆ๏€’๏€ณ๏€Ÿ๏€จ๏€œ๏€ฉ๏€ช๏€’๏€๏€‡๏€ƒ๏€Š๏€๏€Š๏€ƒ
๏€™๏€ซ๏€๏€ญ๏€ช
๏€‘๏€ฎ๏€ฉ๏€ช
๏€„๏€ฏ๏€‚๏€‚๏€ฏ๏€ƒ๏€๏€‚๏€‡
๏€”๏€Ÿ๏€จ๏€œ๏€ช๏€ซ๏€’
๏€ฅ๏€ญ๏€ช๏€ช๏€œ๏€ฉ
๏€๏€ฉ๏€ฎ๏€œ๏€ฐ
๏€›๏€ฉ๏€๏€ž๏€ฅ๏€ฉ
๏€•๏€˜ ๏€•๏€ฑ๏€ฐ๏€œ
๏€ฒ๏€œ๏€ฉ๏€ณ๏€ค๏€œ
๏€™๏€ด๏€–๏€ฏ๏€๏€‡๏€ƒ๏€Š๏€๏€Š๏€ƒ๏€ฏ๏€‘๏€š
๏€—๏€ค๏€ฅ๏€๏€จ๏€œ๏€ฉ๏€ช
๏€‚๏€ž๏€
๏€†๏€‚
๏€†๏€„
๏€†๏€ƒ
๏€ต๏€’๏€’๏€ข๏€’๏€’๏€ค๏€’๏€’๏€ช๏€’๏€’๏€ซ๏€’๏€’๏€ซ๏€’๏€’๏€๏€’๏€’๏€๏€’๏€’๏€œ๏€’๏€’๏€Ÿ๏€’๏€’๏€จ๏€’๏€’๏€ฅ๏€’๏€’๏€ค๏€’๏€’๏€œ๏€’๏€’๏€ต
๏€
๏€๏€‚๏€‚๏€“๏€ƒ๏€‚๏€„
๏€ƒ๏€˜๏€“๏€๏€ƒ๏€‚๏€„
๏€œ๏€ฅ๏€ผ๏€ž๏€ž๏€ž
๏€•๏€›๏€“๏€ƒ๏€‚๏€„
๏€๏€œ๏€ฉ๏€ญ๏€ฆ๏€’๏€ฅ๏€ซ๏€ซ๏€ฉ
๏€จ๏€œ๏€๏€’๏€ช๏€œ๏€ฅ๏€ญ
๏€บ๏€ค๏€ป๏€ผ๏€ค๏€ฆ๏€๏€’๏€จ๏€œ๏€
๏€ต๏€ฅ๏€ค๏€ฐ๏€ฐ๏€œ๏€ฉ๏€œ๏€ฅ๏€ฃ๏€œ๏€’๏€Ÿ๏€ค๏€ป๏€ ๏€œ๏€ฉ
๏€ฅ๏€ซ๏€ซ๏€ฉ๏€’๏€จ๏€œ๏€๏€’๏€ฝ๏€ฎ๏€ข๏€ฆ๏€œ๏€ฅ๏€ฃ๏€œ
๏€Ÿ๏€ค๏€ป๏€ ๏€œ๏€ฉ๏€’๏€ฆ๏€ซ๏€ซ๏€ฅ
๏€๏€‚ ๏€๏€‚
๏€๏€‚
๏€…๏€ ๏€‡๏€ก๏€…๏€Œ๏€–๏€ข๏€ˆ๏€ ๏€‡๏€…๏€…
๏€–๏€–๏€‡๏€–๏€–๏€Œ๏€–๏€ข๏€–๏€–๏€‡๏€–๏€–๏€…๏€ ๏€‡๏€ก๏€…๏€Œ๏€–๏€ข๏€ˆ๏€ ๏€‡๏€…๏€…
๏€๏€Ž๏€™๏€‚๏€‰๏€๏€‘๏€’๏€˜๏€๏€ƒ๏€๏€“
๏€˜๏€“๏€„๏€๏€š๏€๏€“๏€ž๏€Ÿ๏€˜๏€๏€•๏€˜๏€„๏€๏€“
๏€๏€‚๏€‚๏€“๏€ƒ๏€‚๏€„
๏€๏€‚
๏€–๏€–๏€‡๏€–๏€–๏€Œ๏€–๏€ข๏€–๏€–๏€‡๏€–๏€–
๏€๏€‚๏€‚๏€“๏€ƒ๏€‚๏€„
๏€บ๏€ค๏€ป๏€ผ๏€ค๏€ฆ๏€๏€’๏€จ๏€œ๏€
๏€ต๏€ฅ๏€ค๏€ฐ๏€ฐ๏€œ๏€ฉ๏€œ๏€ฅ๏€ฃ๏€œ๏€’๏€Ÿ๏€ค๏€ป๏€ ๏€œ๏€ฉ
๏€ฅ๏€ซ๏€ซ๏€ฉ๏€’๏€จ๏€œ๏€๏€’๏€ฝ๏€ฎ๏€ข๏€ฆ๏€œ๏€ฅ๏€ฃ๏€œ
๏€Ÿ๏€ค๏€ป๏€ ๏€œ๏€ฉ๏€’๏€ฆ๏€ซ๏€ซ๏€ฅ
๏€๏€‚
๏€–๏€–๏€‡๏€–๏€–๏€Œ๏€–๏€ข๏€–๏€–๏€‡๏€–๏€–
๏€ˆ๏€—
๏€ก๏€ˆ๏€ก
52
5.6 Dag-/nachttemperatuur wijzigen
5.7 Tijd en datum wijzigen
5.8 Vakantieregeling instellen
Gedurende het ingestelde tijdsblok, zal de regeling regelen volgens de nachttemperatuur.
5.9 Menu code wijzigen
๏€ ๏€‚ ๏€ƒ ๏€„ ๏€… ๏€† ๏€‡ ๏€ˆ ๏€‰ ๏€Š ๏€‚๏€ ๏€‚๏€‚ ๏€‚๏€ƒ ๏€‚๏€„ ๏€‚๏€… ๏€‚๏€† ๏€‚๏€‡ ๏€‚๏€ˆ ๏€‚๏€‰ ๏€‚๏€Š
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€๏€‘๏€Ž๏€”๏€•๏€๏€Ž๏€–๏€•๏€Ž๏€Ž๏€
๏€—๏€Œ๏€‘๏€•๏€˜๏€๏€๏€“๏€’๏€‘๏€๏€™๏€๏€๏€š๏€›๏€‘๏€™๏€”
๏€๏€œ๏€๏€ž
๏€๏€œ๏€Ÿ๏€ž
๏€›๏€ ๏€ก๏€œ๏€œ๏€ข๏€ฃ๏€ค๏€ฅ๏€ฆ๏€’๏€ณ๏€Ÿ๏€จ๏€œ๏€ฉ๏€ช๏€’๏€๏€‡๏€ƒ๏€Š๏€๏€Š๏€ƒ
๏€™๏€ซ๏€๏€ญ๏€ช
๏€‘๏€ฎ๏€ฉ๏€ช
๏€„๏€ฏ๏€‚๏€‚๏€ฏ๏€ƒ๏€๏€‚๏€‡
๏€”๏€Ÿ๏€จ๏€œ๏€ช๏€ซ๏€’
๏€ฅ๏€ญ๏€ช๏€ช๏€œ๏€ฉ
๏€๏€ฉ๏€ฎ๏€œ๏€ฐ
๏€›๏€ฉ๏€๏€ž๏€ฅ๏€ฉ
๏€•๏€˜ ๏€•๏€ฑ๏€ฐ๏€œ
๏€ฒ๏€œ๏€ฉ๏€ณ๏€ค๏€œ
๏€™๏€ด๏€–๏€ฏ๏€๏€‡๏€ƒ๏€Š๏€๏€Š๏€ƒ๏€ฏ๏€‘๏€š
๏€—๏€ค๏€ฅ๏€๏€จ๏€œ๏€ฉ๏€ช
๏€‚๏€ž๏€
๏€†๏€ƒ
๏€†๏€…
๏€†๏€„
๏€ต๏€’๏€’๏€ข๏€’๏€’๏€ค๏€’๏€’๏€ช๏€’๏€’๏€ซ๏€’๏€’๏€ซ๏€’๏€’๏€๏€’๏€’๏€๏€’๏€’๏€œ๏€’๏€’๏€Ÿ๏€’๏€’๏€จ๏€’๏€’๏€ฅ๏€’๏€’๏€ค๏€’๏€’๏€œ๏€’๏€’๏€ต
๏€
๏€ˆ๏€†๏€๏€Ž
๏€ƒ๏€‚๏€„๏€’๏€๏€๏€ฃ๏€๏€œ๏€‚๏€’๏€”๏€”๏€œ
๏€“๏€‚๏€Ž๏€™๏€’๏€’๏€๏€๏€ฃ๏€๏€œ๏€‚๏€’๏€”๏€”๏€œ
๏€ณ๏€œ๏€ข๏€œ๏€Ÿ๏€๏€œ๏€œ๏€ฉ
๏€๏€œ๏€ฉ๏€ญ๏€ฆ๏€’๏€ฅ๏€ซ๏€ซ๏€ฉ
๏€จ๏€œ๏€๏€’๏€ช๏€œ๏€ฅ๏€ญ
๏€บ๏€ค๏€ป๏€ผ๏€ค๏€ฆ๏€๏€’๏€จ๏€œ๏€
๏€ต๏€ฅ๏€ค๏€ฐ๏€ฐ๏€œ๏€ฉ๏€œ๏€ฅ๏€ฃ๏€œ๏€’๏€Ÿ๏€ค๏€ป๏€ ๏€œ๏€ฉ
๏€ฅ๏€ซ๏€ซ๏€ฉ๏€’๏€จ๏€œ๏€๏€’๏€ฝ๏€ฎ๏€ข๏€ฆ๏€œ๏€ฅ๏€ฃ๏€œ
๏€Ÿ๏€ค๏€ป๏€ ๏€œ๏€ฉ๏€’๏€ฆ๏€ซ๏€ซ๏€ฅ
๏€บ๏€ค๏€ป๏€ผ๏€ค๏€ฆ๏€๏€’๏€จ๏€œ๏€
๏€ต๏€ฅ๏€ค๏€ฐ๏€ฐ๏€œ๏€ฉ๏€œ๏€ฅ๏€ฃ๏€œ๏€’๏€Ÿ๏€ค๏€ป๏€ ๏€œ๏€ฉ
๏€ฅ๏€ซ๏€ซ๏€ฉ๏€’๏€จ๏€œ๏€๏€’๏€ฝ๏€ฎ๏€ข๏€ฆ๏€œ๏€ฅ๏€ฃ๏€œ
๏€Ÿ๏€ค๏€ป๏€ ๏€œ๏€ฉ๏€’๏€ฆ๏€ซ๏€ซ๏€ฅ
๏€๏€‚ ๏€๏€‚
๏€๏€‚
๏€…๏€†๏€๏€Ž
๏€„๏€๏€Ÿ๏€๏€“๏€๏€’๏€
๏€’๏€๏€๏€ฃ๏€๏€œ๏€‚๏€’๏€”๏€”๏€œ
๏€ ๏€‚ ๏€ƒ ๏€„ ๏€… ๏€† ๏€‡ ๏€ˆ ๏€‰ ๏€Š ๏€‚๏€ ๏€‚๏€‚ ๏€‚๏€ƒ ๏€‚๏€„ ๏€‚๏€… ๏€‚๏€† ๏€‚๏€‡ ๏€‚๏€ˆ ๏€‚๏€‰ ๏€‚๏€Š
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€๏€‘๏€Ž๏€”๏€•๏€๏€Ž๏€–๏€•๏€Ž๏€Ž๏€
๏€—๏€Œ๏€‘๏€•๏€˜๏€๏€๏€“๏€’๏€‘๏€๏€™๏€๏€๏€š๏€›๏€‘๏€™๏€”
๏€๏€œ๏€๏€ž
๏€๏€œ๏€Ÿ๏€ž
๏€›๏€ ๏€ก๏€œ๏€œ๏€ข๏€ฃ๏€ค๏€ฅ๏€ฆ๏€’๏€ณ๏€Ÿ๏€จ๏€œ๏€ฉ๏€ช๏€’๏€๏€‡๏€ƒ๏€Š๏€๏€Š๏€ƒ
๏€™๏€ซ๏€๏€ญ๏€ช
๏€‘๏€ฎ๏€ฉ๏€ช
๏€„๏€ฏ๏€‚๏€‚๏€ฏ๏€ƒ๏€๏€‚๏€‡
๏€”๏€Ÿ๏€จ๏€œ๏€ช๏€ซ๏€’
๏€ฅ๏€ญ๏€ช๏€ช๏€œ๏€ฉ
๏€๏€ฉ๏€ฎ๏€œ๏€ฐ
๏€›๏€ฉ๏€๏€ž๏€ฅ๏€ฉ
๏€•๏€˜ ๏€•๏€ฑ๏€ฐ๏€œ
๏€ฒ๏€œ๏€ฉ๏€ณ๏€ค๏€œ
๏€™๏€ด๏€–๏€ฏ๏€๏€‡๏€ƒ๏€Š๏€๏€Š๏€ƒ๏€ฏ๏€‘๏€š
๏€—๏€ค๏€ฅ๏€๏€จ๏€œ๏€ฉ๏€ช
๏€‚๏€ž๏€
๏€†๏€„
๏€†๏€†
๏€†๏€…
๏€ต๏€’๏€’๏€ข๏€’๏€’๏€ค๏€’๏€’๏€ช๏€’๏€’๏€ซ๏€’๏€’๏€ซ๏€’๏€’๏€๏€’๏€’๏€๏€’๏€’๏€œ๏€’๏€’๏€Ÿ๏€’๏€’๏€จ๏€’๏€’๏€ฅ๏€’๏€’๏€ค๏€’๏€’๏€œ๏€’๏€’๏€ต
๏€
๏€๏€‚ ๏€—๏€ก๏€–๏€…๏€ก๏€–๏€—๏€…๏€…๏€ค
๏€…๏€ค๏€‡๏€ˆ๏€…๏€‡๏€…๏€…
๏€๏€œ๏€ฉ๏€ญ๏€ฆ๏€’๏€ฅ๏€ซ๏€ซ๏€ฉ
๏€จ๏€œ๏€๏€’๏€ช๏€œ๏€ฅ๏€ญ
๏€ณ๏€œ๏€ข๏€œ๏€Ÿ๏€๏€œ๏€œ๏€ฉ
๏€บ๏€ค๏€ป๏€ผ๏€ค๏€ฆ๏€๏€’๏€จ๏€œ๏€
๏€ต๏€ฅ๏€ค๏€ฐ๏€ฐ๏€œ๏€ฉ๏€œ๏€ฅ๏€ฃ๏€œ๏€’๏€Ÿ๏€ค๏€ป๏€ ๏€œ๏€ฉ
๏€ฅ๏€ซ๏€ซ๏€ฉ๏€’๏€จ๏€œ๏€๏€’๏€ฝ๏€ฎ๏€ข๏€ฆ๏€œ๏€ฅ๏€ฃ๏€œ
๏€Ÿ๏€ค๏€ป๏€ ๏€œ๏€ฉ๏€’๏€ฆ๏€ซ๏€ซ๏€ฅ
๏€๏€‚ ๏€๏€‚
๏€’๏€˜๏€๏€ƒ๏€ž๏€ƒ๏€‚๏€’๏€”๏€
๏€Ÿ๏€˜๏€๏€•๏€˜๏€„๏€๏€“
๏€ ๏€‚ ๏€ƒ ๏€„ ๏€… ๏€† ๏€‡ ๏€ˆ ๏€‰ ๏€Š ๏€‚๏€ ๏€‚๏€‚ ๏€‚๏€ƒ ๏€‚๏€„ ๏€‚๏€… ๏€‚๏€† ๏€‚๏€‡ ๏€‚๏€ˆ ๏€‚๏€‰ ๏€‚๏€Š
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€๏€‘๏€Ž๏€”๏€•๏€๏€Ž๏€–๏€•๏€Ž๏€Ž๏€
๏€—๏€Œ๏€‘๏€•๏€˜๏€๏€๏€“๏€’๏€‘๏€๏€™๏€๏€๏€š๏€›๏€‘๏€™๏€”
๏€๏€œ๏€๏€ž
๏€๏€œ๏€Ÿ๏€ž
๏€›๏€ ๏€ก๏€œ๏€œ๏€ข๏€ฃ๏€ค๏€ฅ๏€ฆ๏€’๏€ณ๏€Ÿ๏€จ๏€œ๏€ฉ๏€ช๏€’๏€๏€‡๏€ƒ๏€Š๏€๏€Š๏€ƒ
๏€™๏€ซ๏€๏€ญ๏€ช
๏€‘๏€ฎ๏€ฉ๏€ช
๏€„๏€ฏ๏€‚๏€‚๏€ฏ๏€ƒ๏€๏€‚๏€‡
๏€”๏€Ÿ๏€จ๏€œ๏€ช๏€ซ๏€’
๏€ฅ๏€ญ๏€ช๏€ช๏€œ๏€ฉ
๏€๏€ฉ๏€ฎ๏€œ๏€ฐ
๏€›๏€ฉ๏€๏€ž๏€ฅ๏€ฉ
๏€•๏€˜ ๏€•๏€ฑ๏€ฐ๏€œ
๏€ฒ๏€œ๏€ฉ๏€ณ๏€ค๏€œ
๏€™๏€ด๏€–๏€ฏ๏€๏€‡๏€ƒ๏€Š๏€๏€Š๏€ƒ๏€ฏ๏€‘๏€š
๏€—๏€ค๏€ฅ๏€๏€จ๏€œ๏€ฉ๏€ช
๏€‚๏€ž๏€
๏€†๏€…
๏€†๏€‡
๏€†๏€†
๏€ต๏€’๏€’๏€ข๏€’๏€’๏€ค๏€’๏€’๏€ช๏€’๏€’๏€ซ๏€’๏€’๏€ซ๏€’๏€’๏€๏€’๏€’๏€๏€’๏€’๏€œ๏€’๏€’๏€Ÿ๏€’๏€’๏€จ๏€’๏€’๏€ฅ๏€’๏€’๏€ค๏€’๏€’๏€œ๏€’๏€’๏€ต
๏€
๏€‰๏€˜๏€๏€๏€Œ๏€“๏€˜๏€๏€”๏€Ÿ๏€๏€Œ๏€Ž๏€›๏€ƒ๏€
๏€๏€Ž๏€๏€—๏€ž๏€๏€˜๏€–๏€๏€’๏€—๏€˜๏€™๏€š๏€›๏€
๏€๏€œ๏€ฉ๏€ญ๏€ฆ๏€’๏€ฅ๏€ซ๏€ซ๏€ฉ
๏€จ๏€œ๏€๏€’๏€ช๏€œ๏€ฅ๏€ญ
๏€ณ๏€œ๏€ข๏€œ๏€Ÿ๏€๏€œ๏€œ๏€ฉ
๏€บ๏€ค๏€ป๏€ผ๏€ค๏€ฆ๏€๏€’๏€จ๏€œ๏€
๏€ต๏€ฅ๏€ค๏€ฐ๏€ฐ๏€œ๏€ฉ๏€œ๏€ฅ๏€ฃ๏€œ๏€’๏€Ÿ๏€ค๏€ป๏€ ๏€œ๏€ฉ
๏€ฅ๏€ซ๏€ซ๏€ฉ๏€’๏€จ๏€œ๏€๏€’๏€ฝ๏€ฎ๏€ข๏€ฆ๏€œ๏€ฅ๏€ฃ๏€œ
๏€Ÿ๏€ค๏€ป๏€ ๏€œ๏€ฉ๏€’๏€ฆ๏€ซ๏€ซ๏€ฅ
๏€๏€‚ ๏€๏€‚
๏€ˆ๏€…๏€…๏€…
๏€๏€๏€“๏€”๏€Œ๏€Ž๏€›๏€ƒ๏€
๏€Ÿ๏€˜๏€๏€•๏€˜๏€„๏€๏€“
VAKANTIEREG. ACT
AAN
terug naar
het menu
select
aan of uit
selecteren
OK OK
VAKANTIEREG. ACT
VAN: 01-07-2017
TOT: 01-08-2017
OK
wijzigt het
knipperende cijfer
naar het volgende
cijfer gaan
53
5.10 Taalkeuze wijzigen
Instelbare talen: NL, EN, DE, FR, PL, RO, LT.
5.11 IJking
In geval van een ongunstige montageplaats van de externe voeler, kan er een afwijking optreden
van de werkelijk gemeten temperatuur door de PinTherm Connect. Dit temperatuurverschil kan
met deze ijkingfunctie worden gecompenseerd door het instellen van een correctiewaarde.
Voorbeeld: De gemeten temperatuur bedraagt 18ยฐC, het beeldscherm op de PinTherm
Connect geeft 20ยฐC aan. Het verschil bedraagt in dit voorbeeld dus 2ยฐC te
hoog de correctiewaarde moet dan ingesteld worden op -2ยฐC.
5.12 Verwarmen/koelen
Instelling om de regelaar geschikt te maken voor het regelen van verwarming of koeling.
๏€ ๏€‚ ๏€ƒ ๏€„ ๏€… ๏€† ๏€‡ ๏€ˆ ๏€‰ ๏€Š ๏€‚๏€ ๏€‚๏€‚ ๏€‚๏€ƒ ๏€‚๏€„ ๏€‚๏€… ๏€‚๏€† ๏€‚๏€‡ ๏€‚๏€ˆ ๏€‚๏€‰ ๏€‚๏€Š
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€๏€‘๏€Ž๏€”๏€•๏€๏€Ž๏€–๏€•๏€Ž๏€Ž๏€
๏€—๏€Œ๏€‘๏€•๏€˜๏€๏€๏€“๏€’๏€‘๏€๏€™๏€๏€๏€š๏€›๏€‘๏€™๏€”
๏€๏€œ๏€๏€ž
๏€๏€œ๏€Ÿ๏€ž
๏€›๏€ ๏€ก๏€œ๏€œ๏€ข๏€ฃ๏€ค๏€ฅ๏€ฆ๏€’๏€ณ๏€Ÿ๏€จ๏€œ๏€ฉ๏€ช๏€’๏€๏€‡๏€ƒ๏€Š๏€๏€Š๏€ƒ
๏€™๏€ซ๏€๏€ญ๏€ช
๏€‘๏€ฎ๏€ฉ๏€ช
๏€„๏€ฏ๏€‚๏€‚๏€ฏ๏€ƒ๏€๏€‚๏€‡
๏€”๏€Ÿ๏€จ๏€œ๏€ช๏€ซ๏€’
๏€ฅ๏€ญ๏€ช๏€ช๏€œ๏€ฉ
๏€๏€ฉ๏€ฎ๏€œ๏€ฐ
๏€›๏€ฉ๏€๏€ž๏€ฅ๏€ฉ
๏€•๏€˜ ๏€•๏€ฑ๏€ฐ๏€œ
๏€ฒ๏€œ๏€ฉ๏€ณ๏€ค๏€œ
๏€™๏€ด๏€–๏€ฏ๏€๏€‡๏€ƒ๏€Š๏€๏€Š๏€ƒ๏€ฏ๏€‘๏€š
๏€—๏€ค๏€ฅ๏€๏€จ๏€œ๏€ฉ๏€ช
๏€‚๏€ž๏€
๏€†๏€†
๏€†๏€ˆ
๏€†๏€‡
๏€ต๏€’๏€’๏€ข๏€’๏€’๏€ค๏€’๏€’๏€ช๏€’๏€’๏€ซ๏€’๏€’๏€ซ๏€’๏€’๏€๏€’๏€’๏€๏€’๏€’๏€œ๏€’๏€’๏€Ÿ๏€’๏€’๏€จ๏€’๏€’๏€ฅ๏€’๏€’๏€ค๏€’๏€’๏€œ๏€’๏€’๏€ต
๏€
๏€“๏€๏€ƒ๏€๏€œ๏€‘๏€‚๏€“๏€ƒ๏€
๏€’๏€‚๏€‚๏€‘๏€‰๏€๏€”๏€•๏€
๏€๏€œ๏€ฉ๏€ญ๏€ฆ๏€’๏€ฅ๏€ซ๏€ซ๏€ฉ
๏€จ๏€œ๏€๏€’๏€ช๏€œ๏€ฅ๏€ญ
๏€ฆ๏€œ๏€บ๏€œ๏€ฅ๏€ณ๏€๏€œ๏€’๏€๏€ซ๏€ซ๏€ข
๏€ณ๏€œ๏€ข๏€œ๏€Ÿ๏€๏€œ๏€ฉ๏€œ๏€ฅ
๏€ณ๏€œ๏€ข๏€œ๏€Ÿ๏€๏€œ๏€œ๏€ฉ
๏€๏€‚ ๏€๏€‚
๏€’๏€‚๏€‚๏€‘๏€‰๏€๏€”๏€•๏€
๏€Ÿ๏€˜๏€๏€•๏€˜๏€„๏€๏€“
๏€ ๏€‚ ๏€ƒ ๏€„ ๏€… ๏€† ๏€‡ ๏€ˆ ๏€‰ ๏€Š ๏€‚๏€ ๏€‚๏€‚ ๏€‚๏€ƒ ๏€‚๏€„ ๏€‚๏€… ๏€‚๏€† ๏€‚๏€‡ ๏€‚๏€ˆ ๏€‚๏€‰ ๏€‚๏€Š
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€๏€‘๏€Ž๏€”๏€•๏€๏€Ž๏€–๏€•๏€Ž๏€Ž๏€
๏€—๏€Œ๏€‘๏€•๏€˜๏€๏€๏€“๏€’๏€‘๏€๏€™๏€๏€๏€š๏€›๏€‘๏€™๏€”
๏€๏€œ๏€๏€ž
๏€๏€œ๏€Ÿ๏€ž
๏€›๏€ ๏€ก๏€œ๏€œ๏€ข๏€ฃ๏€ค๏€ฅ๏€ฆ๏€’๏€ณ๏€Ÿ๏€จ๏€œ๏€ฉ๏€ช๏€’๏€๏€‡๏€ƒ๏€Š๏€๏€Š๏€ƒ
๏€™๏€ซ๏€๏€ญ๏€ช
๏€‘๏€ฎ๏€ฉ๏€ช
๏€„๏€ฏ๏€‚๏€‚๏€ฏ๏€ƒ๏€๏€‚๏€‡
๏€”๏€Ÿ๏€จ๏€œ๏€ช๏€ซ๏€’
๏€ฅ๏€ญ๏€ช๏€ช๏€œ๏€ฉ
๏€๏€ฉ๏€ฎ๏€œ๏€ฐ
๏€›๏€ฉ๏€๏€ž๏€ฅ๏€ฉ
๏€•๏€˜ ๏€•๏€ฑ๏€ฐ๏€œ
๏€ฒ๏€œ๏€ฉ๏€ณ๏€ค๏€œ
๏€™๏€ด๏€–๏€ฏ๏€๏€‡๏€ƒ๏€Š๏€๏€Š๏€ƒ๏€ฏ๏€‘๏€š
๏€—๏€ค๏€ฅ๏€๏€จ๏€œ๏€ฉ๏€ช
๏€‚๏€ž๏€
๏€†๏€‡
๏€†๏€‰
๏€†๏€ˆ
๏€ต๏€’๏€’๏€ข๏€’๏€’๏€ค๏€’๏€’๏€ช๏€’๏€’๏€ซ๏€’๏€’๏€ซ๏€’๏€’๏€๏€’๏€’๏€๏€’๏€’๏€œ๏€’๏€’๏€Ÿ๏€’๏€’๏€จ๏€’๏€’๏€ฅ๏€’๏€’๏€ค๏€’๏€’๏€œ๏€’๏€’๏€ต
๏€
๏€˜๏€๏€‰๏€˜๏€“๏€„ ๏€˜๏€๏€‰๏€˜๏€“๏€„
๏€‡๏€š๏€๏€๏€๏€™๏€“๏€Ž๏€๏€ž๏€‹๏€‹๏€๏€›๏€๏€˜๏€Ž๏€‘๏€˜๏€Ž๏€’๏€‘๏€“๏€๏€”๏€Œ๏€‹๏€‹๏€
๏€๏€œ๏€ฉ๏€ญ๏€ฆ๏€’๏€ฅ๏€ซ๏€ซ๏€ฉ
๏€จ๏€œ๏€๏€’๏€ช๏€œ๏€ฅ๏€ญ
๏€ณ๏€œ๏€ข๏€œ๏€Ÿ๏€๏€œ๏€œ๏€ฉ
๏€บ๏€ค๏€ป๏€ผ๏€ค๏€ฆ๏€๏€’๏€จ๏€œ๏€
๏€ต๏€ฅ๏€ค๏€ฐ๏€ฐ๏€œ๏€ฉ๏€œ๏€ฅ๏€ฃ๏€œ๏€’๏€Ÿ๏€ค๏€ป๏€ ๏€œ๏€ฉ
๏€ฅ๏€ซ๏€ซ๏€ฉ๏€’๏€จ๏€œ๏€๏€’๏€ฝ๏€ฎ๏€ข๏€ฆ๏€œ๏€ฅ๏€ฃ๏€œ
๏€Ÿ๏€ค๏€ป๏€ ๏€œ๏€ฉ๏€’๏€ฆ๏€ซ๏€ซ๏€ฅ
๏€๏€‚ ๏€๏€‚
๏€ฅ๏€Œ๏€…๏€ฆ๏€…๏€๏€Ž
๏€Ÿ๏€‹๏€’๏€˜๏€ ๏€ก๏€ข๏€ฃ๏€ค๏€‡๏€˜๏€“๏€š๏€“๏€˜๏€ฅ๏€ก๏€ข๏€ฃ๏€ค๏€‡
NL
VERWARMEN/KOELEN
VERWARMEN
terug naar
het menu
selecteer
instelling wijzigen
OK
VERWARMEN/KOELEN
OK
54
5.13 Schakeldifferentie
Instelbaar tussen 0,1 en 3,0 K.
5.14 Minimum regelsignaal wijzigen
Opmerking:
Wanneer er geen warmtevraag is, zal de PinTherm Connect een 0Vdc signaal uitsturen.
5.15 Maximum regelsignaal wijzigen
5.16 Range regelsignaal wijzigen
Met deze functie wordt bepaald wanneer het 0-10Vdc signaal wordt terug gemoduleerd tijdens
warmtevraag. Wanneer dit is ingesteld op 1.0 zal de PinTherm Connect 1K onder de gewenste
temperatuur het 0-10V signaal gaan terug moduleren.
De range is instelbaar van 0.5 โ€“ 3.0 en staat standaard ingesteld op 1.0.
SCHAKELDIFF.
1.0K
terug naar
het menu
selecteer
wijzigt het
knipperende cijfer
OK
SCHAKELDIFF.
OK
terug naar
het menu
selecteer
instelling wijzigen
OK OK
0-10V Range(1-3)
1.0
0-10V Range(1-3)
terug naar
het menu
selecteer
instelling wijzigen
OK OK
0-10V min(0-5V)
2.0 V
0-10V min(0-5V)
terug naar
het menu
selecteer
instelling wijzigen
OK OK
0-10V max(5-10V)
10.0 V
0-10V max(5-10V)
55
NL
5.17 ModBus
Slave ID: instelbaar 1 - 247
Fabrieksinstelling: 1
5.18 Ethernet Info
Weergave ingestelde IP-adres.
5.19 IP-instellingen
DHCP - automatische toewijzing IP-adres
Statisch - IP-adres instellen vast adres
SUBnet Mask
5.20 Overwerktimer in- /uitschakelen
Met deze functie bestaat de mogelijkheid om, buiten de ingestelde schakeltijden, handmatig 1, 2 of
3 uur naar de dagtemperatuur te schakelen.
De gele led met het symbool gaat branden ten teken dat de functie is ingeschakeld. Tevens zal
op het display rechtsonder de resterende tijd in minuten worden weergegeven voordat de functie
weer uitschakelt en de PinTherm Connect weer functioneert op de nachttemperatuur. Tussentijds
kan de functie ook weer worden uitgeschakeld door de drukknop in te drukken totdat de gele led
uitgaat en het aantal minuten niet meer in het display worden weergegeven.
IP-ADRES
192.168.001.100
terug naar
het menu
selecteer
OK OK
ETHERNET INFO
MAC-ADRES
5410EC220037
OK
IP MODUS
STATISCH
terug naar
het menu
selecteer
OK OK
IP INSTELLINGEN
IP-ADRES
192.168.001.100
OK
instelling wijzigen
wijzigt het
knipperende cijfer
naar het volgende
cijfer gaan
SUBNET MASK
255.255.255.000
wijzigt het
knipperende cijfer
naar het volgende
cijfer gaan
MODBUS INST.
001
terug naar
het menu
selecteer
wijzigt het
knipperende cijfer
OK
MODBUS
OK
naar het volgende
cijfer gaan
56
Zie onderstaande afbeelding.
5.21 Schoorsteenvegerfunctie inschakelen
Hiermee kunt het toestel tijdelijk op vollast/deellast laten verwarmen om metingen e.d. te kunnen
verrichten. Hieronder staat aangegeven hoe u deze functie kunt in-/uitschakelen. Na inschakeling
blijft deze functie 15 minuten actief en zal daarna automatisch weer uitschakelen.
5.22 Terugplaatsen fabrieksinstellingen PinTherm Connect
Als u deze functie uitvoerd worden alle fabrieksinstellingen weer teruggezet. Deze functie kan
altijd worden uitgevoerd. Zie onderstaande afbeelding.
6.0 Afdanken PinTherm Connect
Wanneer de PinTherm Connect wordt vervangen of verwijdert dient deze conform landelijke en/
of plaatselijke verordeningen te worden gerecycled of vernietigd.
7.0 Modbus
- Communicatie [12]
- Modbus-lijst [13]
๏€ ๏€‚ ๏€ƒ ๏€„ ๏€… ๏€† ๏€‡ ๏€ˆ ๏€‰ ๏€Š ๏€‚๏€ ๏€‚๏€‚ ๏€‚๏€ƒ ๏€‚๏€„ ๏€‚๏€… ๏€‚๏€† ๏€‚๏€‡ ๏€‚๏€ˆ ๏€‚๏€‰ ๏€‚๏€Š
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€๏€‘๏€Ž๏€”๏€•๏€๏€Ž๏€–๏€•๏€Ž๏€Ž๏€
๏€—๏€Œ๏€‘๏€•๏€˜๏€๏€๏€“๏€’๏€‘๏€๏€™๏€๏€๏€š๏€›๏€‘๏€™๏€”
๏€๏€œ๏€๏€ž
๏€๏€œ๏€Ÿ๏€ž
๏€›๏€ ๏€ก๏€œ๏€œ๏€ข๏€ฃ๏€ค๏€ฅ๏€ฆ๏€’๏€ณ๏€Ÿ๏€จ๏€œ๏€ฉ๏€ช๏€’๏€๏€‡๏€ƒ๏€Š๏€๏€Š๏€ƒ
๏€™๏€ซ๏€๏€ญ๏€ช
๏€‘๏€ฎ๏€ฉ๏€ช
๏€„๏€ฏ๏€‚๏€‚๏€ฏ๏€ƒ๏€๏€‚๏€‡
๏€”๏€Ÿ๏€จ๏€œ๏€ช๏€ซ๏€’
๏€ฅ๏€ญ๏€ช๏€ช๏€œ๏€ฉ
๏€๏€ฉ๏€ฎ๏€œ๏€ฐ
๏€›๏€ฉ๏€๏€ž๏€ฅ๏€ฉ
๏€•๏€˜ ๏€•๏€ฑ๏€ฐ๏€œ
๏€ฒ๏€œ๏€ฉ๏€ณ๏€ค๏€œ
๏€™๏€ด๏€–๏€ฏ๏€๏€‡๏€ƒ๏€Š๏€๏€Š๏€ƒ๏€ฏ๏€‘๏€š
๏€—๏€ค๏€ฅ๏€๏€จ๏€œ๏€ฉ๏€ช
๏€‚๏€ž๏€
๏€†๏€‰
๏€‡๏€
๏€†๏€Š
๏€ต๏€’๏€’๏€ข๏€’๏€’๏€ค๏€’๏€’๏€ช๏€’๏€’๏€ซ๏€’๏€’๏€ซ๏€’๏€’๏€๏€’๏€’๏€๏€’๏€’๏€œ๏€’๏€’๏€Ÿ๏€’๏€’๏€จ๏€’๏€’๏€ฅ๏€’๏€’๏€ค๏€’๏€’๏€œ๏€’๏€’๏€ต
๏€
๏€“๏€‚๏€Ž๏€™๏€’
๏€๏€‚ ๏€ˆ๏€ ๏€‡๏€…๏€ˆ ๏€Œ๏€๏€Ž
๏€Š๏€‡๏€…๏€‹๏€…
๏€๏€‚
๏€ƒ๏€‚๏€„
๏€ˆ๏€ ๏€‡๏€…๏€ˆ ๏€Œ๏€ˆ๏€†
๏€Š๏€‡๏€ˆ๏€—๏€…
๏€๏€‚
๏€ƒ๏€‚๏€„
๏€ˆ๏€ ๏€‡๏€…๏€ˆ
๏€Š๏€‡๏€ˆ๏€†๏€…
๏€๏€‚
๏€ƒ๏€‚๏€„
๏€ˆ๏€ ๏€‡๏€…๏€ˆ ๏€Œ๏€ˆ๏€†๏€Œ๏€๏€Ž๏€Œ๏€ˆ๏€†๏€Œ๏€๏€Ž
๏€Œ๏€ˆ๏€†๏€Œ๏€๏€Ž
Hiermee beeindigd u de functie en keert u
terug naar het hoofdscherm
ESC
0-10V
10V
14:59
druk om de voltage te verhogen (max. 10V)
Maak gebruik van onderstaande drukknoppen om het
toestel op een lagere voltage (deellast) te laten functioneren
druk om de voltage te verlagen
ยฑ12sec. Ingedrukt
houden
0
๏€ ๏€‚ ๏€ƒ ๏€„ ๏€… ๏€† ๏€‡ ๏€ˆ ๏€‰ ๏€Š ๏€‚๏€ ๏€‚๏€‚ ๏€‚๏€ƒ ๏€‚๏€„ ๏€‚๏€… ๏€‚๏€† ๏€‚๏€‡ ๏€‚๏€ˆ ๏€‚๏€‰ ๏€‚๏€Š
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€๏€‘๏€Ž๏€”๏€•๏€๏€Ž๏€–๏€•๏€Ž๏€Ž๏€
๏€—๏€Œ๏€‘๏€•๏€˜๏€๏€๏€“๏€’๏€‘๏€๏€™๏€๏€๏€š๏€›๏€‘๏€™๏€”
๏€๏€œ๏€๏€ž
๏€๏€œ๏€Ÿ๏€ž
๏€›๏€ ๏€ก๏€œ๏€œ๏€ข๏€ฃ๏€ค๏€ฅ๏€ฆ๏€’๏€ณ๏€Ÿ๏€จ๏€œ๏€ฉ๏€ช๏€’๏€๏€‡๏€ƒ๏€Š๏€๏€Š๏€ƒ
๏€™๏€ซ๏€๏€ญ๏€ช
๏€‘๏€ฎ๏€ฉ๏€ช
๏€„๏€ฏ๏€‚๏€‚๏€ฏ๏€ƒ๏€๏€‚๏€‡
๏€”๏€Ÿ๏€จ๏€œ๏€ช๏€ซ๏€’
๏€ฅ๏€ญ๏€ช๏€ช๏€œ๏€ฉ
๏€๏€ฉ๏€ฎ๏€œ๏€ฐ
๏€›๏€ฉ๏€๏€ž๏€ฅ๏€ฉ
๏€•๏€˜ ๏€•๏€ฑ๏€ฐ๏€œ
๏€ฒ๏€œ๏€ฉ๏€ณ๏€ค๏€œ
๏€™๏€ด๏€–๏€ฏ๏€๏€‡๏€ƒ๏€Š๏€๏€Š๏€ƒ๏€ฏ๏€‘๏€š
๏€—๏€ค๏€ฅ๏€๏€จ๏€œ๏€ฉ๏€ช
๏€‚๏€ž๏€
๏€†๏€Š
๏€‡๏€‚
๏€‡๏€
๏€ต๏€’๏€’๏€ข๏€’๏€’๏€ค๏€’๏€’๏€ช๏€’๏€’๏€ซ๏€’๏€’๏€ซ๏€’๏€’๏€๏€’๏€’๏€๏€’๏€’๏€œ๏€’๏€’๏€Ÿ๏€’๏€’๏€จ๏€’๏€’๏€ฅ๏€’๏€’๏€ค๏€’๏€’๏€œ๏€’๏€’๏€ต
๏€
๏€๏€๏€‘๏€๏€Ž๏€’๏€Œ๏€‘๏€‚๏€“๏€„๏€”๏€‚๏€„๏€
๏€Œ๏€๏€Ž๏€๏€‚
๏€ƒ๏€‚๏€„
๏€…๏€†๏€‡๏€…๏€ˆ ๏€Œ๏€ˆ๏€‹
๏€พ๏€‚๏€ƒ๏€ณ๏€œ๏€Ÿ๏€ž๏€’๏€Œ๏€ฅ๏€ฆ๏€œ๏€ฃ๏€ฉ๏€ญ๏€ต๏€
๏€จ๏€ฎ๏€ญ๏€ฃ๏€œ๏€ฅ
๏€˜๏€ค๏€œ๏€ฉ๏€ช๏€œ๏€œ๏€’๏€ต๏€œ๏€œ๏€ฉ๏€๏€’๏€ญ๏€’๏€๏€œ๏€ฉ๏€ญ๏€ฆ๏€’๏€ฅ๏€ซ๏€ซ๏€ฉ
๏€จ๏€œ๏€๏€’๏€จ๏€ฎ๏€ฎ๏€ ๏€ฃ๏€ณ๏€Ÿ๏€จ๏€œ๏€ฉ๏€ช๏€’๏€œ๏€ฅ๏€’๏€ผ๏€ญ๏€ข๏€ข๏€œ๏€ฅ๏€’๏€ฃ๏€œ
๏€ ๏€ซ๏€ก๏€ฉ๏€ค๏€œ๏€ต๏€ณ๏€บ๏€ซ๏€ซ๏€ฉ๏€ฃ๏€œ๏€ฅ๏€’๏€ฅ๏€ค๏€œ๏€๏€’๏€บ๏€ฎ๏€ฉ๏€ฃ๏€œ๏€ฅ
๏€๏€œ๏€ฉ๏€ญ๏€ฆ๏€ฆ๏€œ๏€ฐ๏€ข๏€ซ๏€ซ๏€๏€ณ๏€๏€ฟ
๏€๏€‚ ๏€๏€‚
๏€„๏€…๏€‡
๏€๏€“๏€„๏€‘๏€˜๏€๏€™
๏€จ๏€‚๏€ง๏€œ๏€˜๏€๏€‰๏€๏€Ÿ๏€‚๏€‚๏€œ๏€ƒ๏€๏€“
๏€™๏€๏€œ๏€๏€’๏€๏€‘๏€ƒ๏€ฉ
๏€™๏€๏€œ๏€๏€’๏€๏€‘๏€‘๏€๏€“
๏€จ๏€‚๏€ง๏€œ๏€˜๏€๏€‰๏€๏€Ÿ๏€‚๏€‚๏€œ๏€ƒ๏€๏€“๏€ช
57
NL
8.0 Aansluitmogelijkheden PinTherm Connect
L N Voedingsklemmen (230Vac/50Hz)
21 - 22 Continue ventileren
21 - 23 Verwarmen/koelen
24 - 25 Storingslamp
25 - 26 Reset
+ - 0-10Vdc (Verwarmen/koelen)
11 - 12 Externe temperatuursensor
A - B MODBUS RTU (R ground)
RJ 45 connector Internet / Modbus TCP/IP
13 - 14 Contact externe ventilator
Waarschuwing: Gevaarlijke spanning aanwezig op N, L, 13, 14, 21, 22, 23, 24, 25 en 26
Met de PinTherm Connect mogen alleen toestellen aangestuurd worden die voldoen aan de
veiligheidsvoorschriften zoals vastgelegd in EN-IEC 61010-1.
PinTherm Connect
06.29.108
MA
DAG
08:01 18ยบC
X:060
OK
RESET
ESC
0
I
58
Proszฤ™๎€ƒprzeczytaฤ‡๎€ƒniniejszy๎€ƒdokument๎€ƒ
przed๎€ƒinstalacjฤ…๎€ƒurzฤ…dzenia
Ostrzeลผenie
Nieprawidล‚owy montaลผ, regulacja, mody๎ƒ€kacje, naprawa lub konserwacja mogฤ… prowadziฤ‡ do
strat materialnych, obraลผeล„ ciaล‚a lub wybuchu. Wszystkie czynnoล›ci muszฤ… byฤ‡ wykonywane
przez upowaลผnionych, kwali๎ƒ€kowanych specjalistรณw. Gwarancja traci waลผnoล›ฤ‡ w przypadku, gdy
urzฤ…dzenie nie zostanie zainstalowane zgodnie ze wskazรณwkami.
Niniejsze urzฤ…dzenie nie jest przeznaczone do uลผytku przez dzieci lub osoby o obniลผonych
moลผliwoล›ciach ๎ƒ€zycznych, sensorycznych czy umysล‚owych ani teลผ osoby nieposiadajฤ…ce
odpowiedniego doล›wiadczenia czy wiedzy, chyba ลผe osoby takie pozostajฤ… pod nadzorem lub
zostaล‚y przeszkolone w zakresie uลผytkowania urzฤ…dzenia przez osobฤ™ odpowiedzialnฤ… za ich
bezpieczeล„stwo. Naleลผy dopilnowaฤ‡, aby dzieci nie uลผywaล‚y tego urzฤ…dzenia do zabawy.
59
PL
1.0๎€ƒSpis๎€ƒtreล›ci
2.0 Informacje ogรณlne
2.1 Zastrzeลผenia odnoล›nie zmian str. 4
2.2 Ogรณlne ostrzeลผenia str. 4
3.0 Dane techniczne
3.1 Dane techniczne termostatu PinTherm Connect str. 4
3.2 Dane techniczne zewnฤ™trznego czujnika temperatury str. 5
pomieszczenia (opcjonalnie)
3.3 Tabela rezystancji (zewnฤ™trznego) czujnika temperatury str. 5
pomieszczenia
3.4 Ustawienia domyล›lne termostatu PinTherm Connect str. 5
4.0 Instalacja
4.1 Informacje ogรณlne str. 6
4.2 Montaลผ termostatu PinTherm Connect str. 6
4.3 Montaลผ zewnฤ™trznego czujnika temperatury str. 6
pomieszczenia (opcjonalnie)
5.0๎€ƒ๎€ƒInstrukcja๎€ƒobsล‚ugi
5.1 Objaล›nienie funkcji przyciskรณw i wskaลบnikรณw str. 7
5.2 Objaล›nienie pozycji na wyล›wietlaczu str. 8
5.3 Pierwsze uruchomienie termostatu PinTherm Connect str. 8
5.4 Aktywacja menu uลผytkownika str. 9
5.5 Wprowadzanie/zmiana programu str. 9
5.6 Zmiana temperatury dziennej/nocnej str. 10
5.7 Zmiana godziny i daty str. 10
5.8 Ustawienia wakacyjne str. 10
5.9 Zmiana kodu menu str. 10
5.10 Zmiana jฤ™zyka str. 11
5.11 Skalowanie temperatury str. 11
5.12 Ogrzewanie/Chล‚odzenie str. 11
5.13 Rรณลผnica zaล‚ฤ…czania str. 12
5.14 Zmiana minimalnej wartoล›ci sygnaล‚u sterujฤ…cego str. 12
5.15 Zmiana maksymalnej wartoล›ci sygnaล‚u sterujฤ…cego str. 12
5.16 Zmiana zakresu sygnaล‚u sterujฤ…cego str. 12
5.17 Modbus str. 13
5.18 Informacja o Ethernet str. 13
5.19 Ustawienia IP str. 13
5.20 Wล‚ฤ…czanie/wyล‚ฤ…czanie zegara dodatkowych godzin str. 13
5.21 Uruchamianie funkcji oczyszczania komina str. 14
5.22 Przywracanie ustawieล„ domyล›lnych termostatu str. 14
PinTherm Connect
6.0๎€ƒ๎€ƒUtylizacja๎€ƒtermostatu๎€ƒPinTherm๎€ƒConnect str. 14
7.0 Modbus str. 14
8.0๎€ƒ๎€ƒMoลผliwoล›ci๎€ƒpoล‚ฤ…czenia๎€ƒtermostatu๎€ƒPinTherm๎€ƒConnect str. 15
Zaล‚ฤ…cznik๎€ƒI๎€ƒ๎€ƒSchematy๎€ƒokablowania str. 87
Zaล‚ฤ…cznik๎€ƒII๎€ƒModbus str. 94
60
2.0 Informacje ogรณlne
2.1 Zastrzeลผenia odnoล›nie zmian
Celem producenta jest ciฤ…gล‚e udoskonalanie swoich produktรณw, w zwiฤ…zku z czym zastrzega
on sobie prawo do wprowadzania zmian w specy๎ƒ€kacjach bez wczeล›niejszego uprzedzenia.
Szczegรณล‚owe dane techniczne uznaje siฤ™ za prawidล‚owe, jednak nie stanowiฤ… one podstawy umowy
lub gwarancji. Wszelkie zamรณwienia sฤ… realizowane zgodnie ze standardowymi postanowieniami
ogรณlnych warunkรณw ๎ƒ€rmy dotyczฤ…cych sprzedaลผy i dostaw (dostฤ™pnych na ลผyczenie).
2.2 Ogรณlne ostrzeลผenia
Instalacja urzฤ…dzenia powinna odbywaฤ‡ siฤ™ zgodnie obowiฤ…zujฤ…cymi normami lokalnymi i/lub
krajowymi. Z tego powodu zaleca siฤ™, aby instalacja termostatu PinTherm Connect zostaล‚a
przeprowadzona przez kompetentnego i wykwali๎ƒ€kowanego montera, z uwzglฤ™dnieniem
ustawodawstwa krajowego i miฤ™dzynarodowego. Nieprawidล‚owo przeprowadzona instalacja,
regulacja, mody๎ƒ€kacja oraz czynnoล›ci konserwacyjne lub naprawcze prowadzฤ… do wygaล›niฤ™cia
gwarancji.
Zawsze wyล‚ฤ…czaj zasilanie 230 V przed podล‚ฤ…czeniem zaciskรณw. Napiฤ™cie sieciowe w urzฤ…dzeniu
PinTherm Connect musi byฤ‡ wyล‚ฤ…czane w sposรณb dwubiegunowy za pomocฤ… staล‚ego przeล‚ฤ…cznika,
ktรณry jest odpowiedni dla napiฤ™cia 250VAC / 10A i jest zgodny z obowiฤ…zujฤ…cymi przepisami
bezpieczeล„stwa.
Sterownika PinTherm Connect uลผywaฤ‡ moลผna tylko do sterowania urzฤ…dzeniami speล‚niajฤ…cymi
wymogi normy EN-IEC 61010-1.
Przy uลผyciu mokrej szmatki, wytrzyj obudowฤ™ sterownika PinTherm Connect. Nie uลผywaj
rozpuszczalnikรณw.
Nie ma wymagaล„ dotyczฤ…cych wentylacji w bezpoล›rednim sฤ…siedztwie sterownika.
Uwaga - ryzyko poraลผenia prฤ…dem.
Uwaga - ogรณlne ostrzeลผenie,naraลผenie na niebezpieczeล„stwo.
Pod zaciskami przyล‚ฤ…czeniowymi, ktรณre oznaczono, moลผe znajdowaฤ‡ siฤ™ napiฤ™cie.
3.0 Dane techniczne
3.1 Dane techniczne termostatu PinTherm Connect
โ€ข Oznaczenie typu : PinTherm Connect
โ€ข Numer produktu : 06 29 108
โ€ข Zasilanie PinTherm Connect : 90 โ€“ 240 VAC / 47-63Hz
โ€ข Wล‚asne zuลผycie energii : < 9W
โ€ข Zegar : zegar 24-godzinny z funkcjฤ… automatycznego przeล‚ฤ…czania
trybรณw lato/zima
โ€ข Przeล‚ฤ…czanie programรณw : 3 programy dziennie
โ€ข Przeล‚ฤ…cznik dyferencyjny : 0,1 - 3K
โ€ข Wymiary : 166 x 160 x 106mm (lxwxh)
โ€ข Waga : 880 gram
โ€ข Klasa ochrony : IP-54
โ€ข ลšrodowisko instalacji : Transport/przechowywanie: -20ยฐC do +70ยฐC.
Praca: -10ยฐC do +60ยฐC
Wilgotnoล›ฤ‡ wzglฤ™dna: 0-90% przy braku kondensacji
Instalacja maksymalnie 2000 metrรณw nad poziomem morza.
!
!
61
PL
โ€ข Kategoria przepiฤ™ciowa : 11
โ€ข Poziom zanieczyszczeล„ : 2
โ€ข Przeล‚ฤ…cznik(i)* : Ogrzewanie: 230Vac/16A (4A)
Pozostaล‚e: 230Vac/10A (2,5A)
โ€ข Ustawienia temperatury : 0 do 39ยฐC per 1ยฐC z moลผliwoล›ciฤ… regulacji
โ€ข Zegar nadgodzin : moลผliwoล›ฤ‡ regulacji 1, 2 lub 3 godziny (060, 120, 180)
โ€ข Kalibracja : moลผliwoล›ฤ‡ regulacji od -3.5ยฐC do +3.5ยฐC
โ€ข Ogrzewanie/chล‚odzenie : Kontakt odwracalny dla ogrzewania i chล‚odzenia
โ€ข 0-10 VDC : styk zasilajฤ…cy 0-10 VDC dla ogrzewania i chล‚odzenia
โ€ข Czujnik : zewnฤ™trzny czujnik temperatury pomieszczeniowej
(06 29 086)
โ€ข Jฤ™zyki : NL/EN/DE/FR/PL/RO/LT
โ€ข Bezpiecznik : 6A
* Styki przekaลบnikowe sฤ… przeล‚ฤ…cznikami funkcjonalnymi, a nie wyล‚ฤ…cznikami bezpieczeล„stwa.
3.2 Dane techniczne zewnฤ™trznego czujnika temperatury pomieszczenia (opcjonalnie)
โ€ข Oznaczenie typu : RSTF NTC4,7K
โ€ข Numer produktu : 06 29 086
โ€ข Rezystancja : NTC 4K7
โ€ข Wymiary : 79 x 81 x 26mm (lxwxh)
โ€ข Masa : 46 grammes
โ€ข Przyล‚ฤ…cza elektryczne : 0.75 -1.5mmยฒ
โ€ข Stopieล„ ochrony : IP-30
3.3 Tabela rezystancji (zewnฤ™trznego) czujnika temperatury pomieszczenia
-15ยฐC -10ยฐC -5ยฐC 0ยฐC 5ยฐC 10ยฐC 15ยฐC
32.937kโ„ฆ 25.217kโ„ฆ 19.392kโ„ฆ 15.040kโ„ฆ 11.743kโ„ฆ 9.241kโ„ฆ 7.330kโ„ฆ
20ยฐC 25ยฐC 30ยฐC 35ยฐC 40ยฐC 45ยฐC 50ยฐC
5.855kโ„ฆ 4.700kโ„ฆ 3.777kโ„ฆ 3.071kโ„ฆ 2.512kโ„ฆ 2.066kโ„ฆ 1.709kโ„ฆ
3.4 Ustawienia domyล›lne termostatu PinTherm Connect
โ€ข Kod menu : 1000
โ€ข Program : Pn, Wt, ลšr, Cz, Pt 07:30-17:30
So, Nd 00:00-00:00
โ€ข Temperatura pomieszczenia : Temperatura dzienna 18ยฐC
Temperatura nocna 08ยฐC
โ€ข Skalowanie temperatury : +0.0
โ€ข Rรณลผnica zaล‚ฤ…czania : 1K
โ€ข Ogrzewanie/Chล‚odzenie : Ogrzewanie
โ€ข 0-10V range : 1K
โ€ข 0-10V min : 0V
โ€ข 0-10V max : 10V
โ€ข Modbus : Slave ID 001
โ€ข Ustawienia IP : statyczny
62
4.0 Instalacja
4.1 Informacje ogรณlne
Po rozpakowaniu termostatu PinTherm Connect i czujnika zewnฤ™trznego (jeล›li zostaล‚ doล‚ฤ…czony
do termostatu), naleลผy sprawdziฤ‡ urzฤ…dzenia pod wzglฤ™dem uszkodzeล„. Sprawdziฤ‡ zgodnoล›ฤ‡ typu/
modelu urzฤ…dzeล„ oraz dziaล‚anie po podล‚ฤ…czeniu do ลบrรณdล‚a zasilania.
4.2 Montaลผ termostatu PinTherm Connect
Okreล›liฤ‡ odpowiednie miejsce do zamontowania termostatu PinTherm Connect. Zamontuj
urzฤ…dzenie PinTherm Connect na stabilnej powierzchni o minimalnym udลบwigu 4 kg. Termostat
PinTherm Connect zaleca siฤ™ umieszczaฤ‡ na wysokoล›ci ยฑ1,5 m od podล‚ogi, w dobrze dostฤ™pnym
miejscu.
Naleลผy uลผywaฤ‡ tylko dล‚awikรณw kablowych wyposaลผonych w zabezpieczenie przed odksztaล‚ceniem,
o minimalnej klasie odpornoล›ci ogniowej UL94V2. Przed podล‚ฤ…czeniem jakichkolwiek przewodรณw,
sprawdลบ, czy zasilanie zostaล‚o wyล‚ฤ…czone. Jeล›li tak nie jest, najpierw naleลผy wyล‚ฤ…czyฤ‡ zasilanie. Po
wyล‚ฤ…czeniu zasilania urzฤ…dzenia, do ktรณrego ma nastฤ…piฤ‡ podล‚ฤ…czenie, naleลผy rรณwnieลผ zapoznaฤ‡ siฤ™
z dokumentacjฤ… technicznฤ… / instrukcjฤ… obsล‚ugi danego urzฤ…dzenia.
Podล‚ฤ…cz urzฤ…dzenie PinTherm Connect zgodnie z dostarczonym schematem elektrycznym,
znajdujฤ…cym siฤ™ z tyล‚u niniejszej instrukcji technicznej. Aby wybraฤ‡ prawidล‚owy schemat poล‚ฤ…czeล„,
musisz wiedzieฤ‡, jakiego typu urzฤ…dzenie chcesz podล‚ฤ…czyฤ‡ do sterownika PinTherm Connect. W
celu dokonania wyboru zapoznaj siฤ™ takลผe z Zaล‚ฤ…cznikiem I.
Podczas stosowania sygnaล‚u 0-10VDC, na podstawie poniลผszej tabeli moลผna okreล›liฤ‡ odpowiedniฤ…
ล›rednicฤ™ i dล‚ugoล›ฤ‡ kabla.
ลšrednica Dล‚ugoล›ฤ‡
0.8mm
2
80 metrรณw
1.0mm
2
100 metrรณw Zasiฤ™gnฤ…ฤ‡ informacji na temat stosowanego kabla
1.5mm
2
150 metrรณw ekranowanego.
4.3 Montaลผ zewnฤ™trznego czujnika temperatury pomieszczenia (opcjonalnie)
Umieล›ciฤ‡ zewnฤ™trzny czujnik pomieszczeniowy poza strefฤ… wystฤ™powania przeciฤ…gรณw, w pobliลผu
uลผฤ…dzenia na wysokoล›ci okoล‚o. 1,5 m od podล‚ogi i podล‚ฤ…cz czujnik do odpowiednich zaciskรณw
w urzฤ…dzeniu PinTherm Connect. Na podstawie poniลผszej tabeli moลผna okreล›liฤ‡ odpowiedniฤ…
ล›rednicฤ™ i dล‚ugoล›ฤ‡ kabla.
ลšrednica Dล‚ugoล›ฤ‡
0.8mm
2
80 meter
1.0mm
2
100 meter Zasiฤ™gnฤ…ฤ‡ informacji na temat stosowanego kabla
1.5mm
2
150 meter ekranowanego.
63
PL
5.0๎€ƒ Instrukcja๎€ƒobsล‚ugi
5.1 Objaล›nienie funkcji przyciskรณw i wskaลบnikรณw
A - Podล›wietlany wyล›wietlacz (patrz rรณwnieลผ 5.2)
B - Przycisk wล‚ฤ…czania lub wyล‚ฤ…czania ogrzewania
C - Dioda wskazujฤ…ca wล‚ฤ…czenie funkcji ogrzewania
D - Przycisk wล‚ฤ…czania lub wyล‚ฤ…czania wentylacji
E - Dioda wskazujฤ…ca wล‚ฤ…czenie funkcji wentylacji
F - Przycisk resetowania urzฤ…dzenia w przypadku awarii (palnika)
G - Dioda informujฤ…ca o awarii (palnika)
H - Przycisk aktywacji menu uลผytkownika lub przejล›cia do nastฤ™pnej wartoล›ci liczbowej
I - Przycisk potwierdzenia dokonanego wyboru/zmiany lub przejล›cia do nastฤ™pnej pozycji menu
J - Przycisk opuszczenia menu lub ustawieล„ bez zastosowania wprowadzonych zmian
K - Przycisk wล‚ฤ…czania lub wyล‚ฤ…czania zegara dodatkowych godzin
L - Przycisk ๏€ต+๏€ถ โ€“ sล‚uลผฤ…cy do zmiany ustawieล„
M - Dioda informujฤ…ca o ลผฤ…daniu uruchomienia ogrzewania (wล‚ฤ…czony palnik)
N - Dioda wskazujฤ…ca wล‚ฤ…czenie wentylatora
O - Dioda wskazujฤ…ca wล‚ฤ…czenie funkcji zegara dodatkowych godzin
C
OK
PinTherm Connect
06.29.108
PN
DZIEN
08:01
E
G
M
N
O
D
F
J K LI
A
B
H
RESET
ESC
0
I
18ยบC
X:060
64
5.2 Objaล›nienie pozycji na wyล›wietlaczu
A - Dzieล„ tygodnia
B - Aktualna godzina
C - Pomiar temperatury (ยฐC).
D - Liczba minut pozostaล‚a do wyล‚ฤ…czenia zegara dodatkowych godzin i przestawienia termostatu
PinTherm Connect na temperaturฤ™ nocnฤ….
E - Wskaลบnik trybu dziennego (DZIEลƒ) lub nocnego (NOC) termostatu PinTherm Connect
ustawiany na podstawie temperatury dziennej i nocnej
5.3 Pierwsze uruchomienie termostatu PinTherm Connect
Podczas pierwszego uruchomienia termostatu PinTherm Connect naleลผy ustawiฤ‡ odpowiedni
jฤ™zyk (dostฤ™pne jฤ™zyki: NL, EN, DE, FR, PL, RO, LT) oraz prawidล‚owฤ… godzinฤ™ i datฤ™. Nastฤ™pnie
termostat PinTherm Connect wyล›wietla ekran gล‚รณwny.
Dostฤ™pne jฤ™zyki: NL, EN, DE, FR, PL, RO, LT
C
PN
DZIEN
08:01
E
D
B
A
18ยบC
X:060
WYBIERZ JEZYKE SO 01-01-2006
00:00:00
16ยฐCPN
DZIEN
08:00
zmiana migajฤ…cej cyfry
przejล›cie do nastฤ™pnej cyfry
wybรณr odpowiedniego
jฤ™zyka
OK OK
ENGLISH
65
PL
5.4 Aktywacja menu uลผytkownika
Ustawienia mogฤ… byฤ‡ zmieniane za pomocฤ… nastฤ™pujฤ…cych pozycji menu:
โ€“ Wprowadลบ/zmieล„ program
โ€“ Zmieล„ temp. dziennฤ…/nocnฤ…
โ€“ Zmieล„ czas/datฤ™
โ€“ Ustawienia wakacyjne
โ€“ Zmieล„ kod menu
โ€“ Zmieล„ jฤ™zyk
โ€“ Skalowanie temp.
โ€“ 0-10V min 0-5V
โ€“ 0-10V max 5-10V
โ€“ 0-10V range (1-3)
โ€“ Modbus
โ€“ Ustawienia IP
5.5 Wprowadzanie/zmiana programu
WPROWADZ KOD
wyjdลบ z menu i wrรณฤ‡ do
okna glรณwnego
kod menu ustawieล„
fabrycznych
1000
16ยฐCPN
DZIEN
08:01
zmieล„ mrugajฤ…cฤ… liczbฤ™
przejdลบ do
nastฤ™pnego numero
wybierz wymagane menu
ESC
OK OK
0000
WPROWADZ/ZMIEN
PROGRAM
PONIEDZIALEK
etc.
powrรณt do
menu
zmieล„ mrugajฤ…cฤ…
liczbฤ™
przejdลบ do
OK
OK
OK
07:30 -> 17:00
WPROWADZ/ZMIEN
PROGAM
PONIEDZIALEK
OK
--:-- -> --:--
zmieล„ mrugajฤ…cฤ…
liczbฤ™
przejdลบ do
OK
12
PONIEDZIALEK
--:-- -> --:--
3 WTOREK
07:30 -> 17:00
1 NIEDZIELA
--:-- -> --:--
3
nastฤ™pnego numero
nastฤ™pnego numero
66
5.6 Zmiana temperatury dziennej/nocnej
5.7 Zmiana godziny i daty
5.8 Ustawienia wakacyjne
W czasie ustawionego bloku czasowego sterowanie bฤ™dzie odbywaฤ‡ siฤ™ w oparciu o temperaturฤ™
nocnฤ….
5.9 Zmiana kodu menu
TRYB WAKACJI AKT
ON
wybierz
wybierz wล‚ฤ…cz
lub wyล‚ฤ…cz
OK OK
USTAWIENIA
WAKACYJNE
OD: 01-07-2017
DO: 01-08-2017
OK
zmieล„ mrugajฤ…cฤ…
liczbฤ™
przejdลบ do
nastฤ™pnego numero
powrรณt do
menu
18ยฐC
TEMP. DZIENNA
TEMP. NOCNA
wybierz
powrรณt do
menu
zmieล„ mrugajฤ…cฤ…
liczbฤ™
przejdลบ do
nastฤ™pnego numero
zmieล„ mrugajฤ…cฤ…
liczbฤ™
przejdลบ do
nastฤ™pnego numero
OK OK
OK
08ยฐC
WPROWADZ/ZMIEN
TEMPERATURE
PN 23-03-2009
09:10:00
wybierz
zmieล„ mrugajฤ…cฤ…
liczbฤ™
przejdลบ do
nastฤ™pnego numero
OK OK
ZMIEN CZAS/DATE
powrรณt do
menu
1000
ZMIEN KOD MENU
WYBIERZ NOWY KOD
Nowy kod menu
powrรณt do
menu
wybierz
zmieล„ mrugajฤ…cฤ…
liczbฤ™
przejdลบ do
nastฤ™pnego numero
OK OK
67
PL
5.10 Zmiana jฤ™zyka
Dostฤ™pne jฤ™zyki: NL, EN, DE, FR, PL, RO, LT.
5.11 Skalowanie temperatury
Jeล›li termostat PinTherm Connect zostaล‚ zamontowany w miejscu niekorzystnym do pomiaru
temperatury, temperatura mierzona przez termostat PinTherm Connect moลผe odbiegaฤ‡ od tem-
peratury rzeczywistej. Rรณลผnicฤ™ temperatur moลผna zrรณwnowaลผyฤ‡ dziฤ™ki funkcji skalowania umoลผli-
wiajฤ…cej ustawienie wartoล›ci korygujฤ…cej. Jeล›li funkcja ta nie przynosi poลผฤ…danych rezultatรณw,
istnieje rรณwnieลผ moลผliwoล›ฤ‡ zamontowania zewnฤ™trznego czujnika temperatury pomieszczenia przy
termostacie PinTherm Connect .
Przykล‚ad: Rzeczywista temperatura to 18ยฐC, a na wyล›wietlaczu termostatu PinTherm Connect
pojawia siฤ™ 20ยฐC. W tym przypadku temperatura na wyล›wietlaczu jest o 2ยฐC za
wysoka - wartoล›ฤ‡ korygujฤ…cฤ… powinna wynieล›ฤ‡ -2ยฐC.
5.12 Ogrzewanie/Chล‚odzenie
Ustawienie trybu sterowania ogrzewaniem lub chล‚odzeniem.
OGRZEW./CHLODZ.
OGRZEWANIE
powrรณt do
menu
wybierz
zmiana ustawien
OK
OGRZEW./CHLODZ.
OK
WYBIERZ JEZYK
POLSKI
powrรณt do
menu
wybierz ลผฤ…dany
jฤ™zyk
wybierz
OK OK
ZMIEN JEZYK
SKALOWANIE TEMP. SKALOWANIE TEMP.
Wartoล›ฤ‡ korygujฤ…cฤ… moลผna regulowaฤ‡
powrรณt do
menu
wybierz
zmieล„ mrugajฤ…cฤ…
liczbฤ™
przejdลบ do
nastฤ™pnego numero
OK OK
+ 0.0ยฐC
od -3,5ยฐC do +3,5ยฐC
68
5.13 Rรณลผnica zaล‚ฤ…czania
Moลผliwoล›ฤ‡ regulacji miฤ™dzy 0.1 a 3.0 K.
5.14 Zmiana minimalnej wartoล›ci sygnaล‚u sterujฤ…cego
Uwaga:
W przypadku braku koniecznoล›ci uruchomienia funkcji ogrzewania termostat PinTherm Connect
wysyล‚a sygnaล‚ o wartoล›ci 0 V DC.
5.15 Zmiana maksymalnej wartoล›ci sygnaล‚u sterujฤ…cego
5.16 Zmiana zakresu sygnaล‚u sterujฤ…cego
Funkcja ta pozwala okreล›liฤ‡, kiedy sygnaล‚ o zakresie 0-10 V DC zostaje ponownie zmodulowany
podczas ลผฤ…dania wล‚ฤ…czenia ogrzewania. Gdy jest on ustawiony na wartoล›ฤ‡ 1.0, termostat PinTherm
Connect ponownie zmoduluje sygnaล‚ 0-10 V o 1 K poniลผej ลผฤ…danej temperatury.
Zakres jest ustawiony w przedziale 0.5-3.0, a jego wartoล›ฤ‡ domyล›lna to 1.0.
PRZELACZANIE
1.0K
powrรณt do
menu
wybierz
wybรณr odpowiedniego
jezyka
OK
PRZELACZANIE
OK
wybierz
zmiana ustawieล„
OK OK
0-10V min(0-5V)
2.0 V
0-10V min(0-5V)
powrรณt do
menu
wybierz
zmiana ustawieล„
OK OK
0-10V max(5-10V)
10.0 V
0-10V max(5-10V)
powrรณt do
menu
wybierz
zmiana ustawieล„
OK OK
0-10V Range(1-3)
1.0
0-10V Range(1-3)
powrรณt do
menu
69
PL
5.17 ModBus
ID Slave: regulacja 1 - 247
Ustawienie fabryczne: 1
5.18 Informacja o Ethernet
Ustawienia adresu IP na wyล›wietlaczu.
5.19 Ustawienia IP
DHCP - automatyczne przypisywanie adresu IP
Statyczny - ustaw staล‚y adres IP
Maska podsieci
5.20 Wล‚ฤ…czanie/wyล‚ฤ…czanie zegara dodatkowych godzin
Funkcja ta pozwala na rฤ™czne przeล‚ฤ…czanie na temperaturฤ™ dziennฤ… o 1, 2 lub 3 godziny poza usta-
wionymi programami.
Aktywacja tej funkcji powoduje zapalenie siฤ™ ลผรณล‚tej diody . Ponadto w prawym dolnym rogu
wyล›wietlacza pojawia siฤ™ czas liczony w minutach, jaki pozostaล‚ do wyล‚ฤ…czenia funkcji i przywrรณce-
nia termostatu Pin Therm Connect do trybu temperatury nocnej. W miฤ™dzyczasie funkcja ta moลผe
rรณwnieลผ zostaฤ‡ wyล‚ฤ…czona za pomocฤ… przycisku โ€“ do zgaล›niฤ™cia ลผรณล‚tej diody i znikniฤ™cia liczby
minut z wyล›wietlacza.
ADRES IP
192.168.001.100
powrรณt do
menu
wybierz
OK OK
ETHERNET INFO
ADRES MAC
5410EC220037
OK
TRYB IP
STATIQ
powrรณt do
menu
wybierz
OK OK
USTAWIENIA IP
ADRES IP
192.168.001.100
OK
zmiana ustawien
zmiana migajacej cyfry
przejscie do nastepnej cyfry
MASKA PODSIECI
255.255.255.000
zmiana migajacej cyfry
przejscie do nastepnej cyfry
USTAWIENIA MODBUS
001
powrรณt do
menu
wybierz
wybรณr odpowiedniego
jezyka
OK
USTAWIENIA
MODBUS
OK
przejscie do nastepnej cyfry
70
Patrz poniลผszy przykล‚ad.
5.21 Uruchamianie funkcji oczyszczania komina
Funkcja umoลผliwia czasowe nagrzanie instalacji przy caล‚kowitym/czฤ™ล›ciowym obciฤ…ลผeniu w celu
przeprowadzenia pomiarรณw itp. Instrukcja aktywacji/dezaktywacji tej funkcji znajduje siฤ™ poniลผej.
Po wล‚ฤ…czeniu funkcja ta pozostaje aktywna przez 15 minut, po czym wyล‚ฤ…cza siฤ™ automatycznie.
5.22 Przywracanie ustawieล„ domyล›lnych termostatu PinTherm Connect
Przeprowadzenie tej operacji spowoduje przywrรณcenie wszystkich ustawieล„ domyล›lnych. Operacjฤ™
moลผna przeprowadziฤ‡ w kaลผdej chwili. Patrz poniลผszy przykล‚ad.
6.0๎€ƒUtylizacja๎€ƒtermostatu๎€ƒPinTherm๎€ƒConnect
Wymiana lub usuwanie termostatu PinTherm Connect w celu jego recyklingu lub wyrzucenia
powinna byฤ‡ zgodna z lokalnymi i/lub krajowymi przepisami.
7.0 Modbus
- Komunikacja [12]
- Lista-Modbus [13]
NOC
PN
X:060
18ยฐC
PN
DZIEN
17:01
X:120
PN
DZIEN
17:01
X:180
PN
DZIEN
17:01
17:01
18ยฐC
18ยฐC
18ยฐC
Nacisnฤ…ฤ‡, aby zatrzymaฤ‡ dziaล‚anie funkcji i
powrรณciฤ‡ do gล‚รณwnego ekranu
ESC
0-10V
10V
14:59
Nacisnฤ…ฤ‡, aby zwiฤ™kszyฤ‡ napiฤ™cie (maks. 10 V)
Uลผyฤ‡ poniลผszych przyciskรณw, aby urzฤ…dzenie pracowaล‚o
na wysokim napiฤ™ciu (przy czฤ™ล›ciowym obciฤ…ลผeniu)
Nacisnฤ…ฤ‡, aby zmniejszyฤ‡ napiฤ™cie (maks.
Przytrzymaฤ‡
wciล›niฤ™ty przez ยฑ12 s
0
naciล›nij i
przytrzymaj przez
okoล‚o 12 sekund.
SELECT LANGUAGE
16ยฐCPN
DZIEN
08:01
w ten sposรณb wrรณcisz do
okna gล‚รณwnego, a wartoล›ci
fabryczne nie zostanฤ…
zastฤ…pione!
OK OK
ESC
ENGLISH
UST. DOMYSLNE
PRZYWROCONE!
PRZYWROCIC UST.
DOMYSLNE?
71
PL
8.0๎€ƒMoลผliwoล›ci๎€ƒpoล‚ฤ…czenia๎€ƒtermostatu๎€ƒPinTherm๎€ƒConnect
L N Zaciski (230Vac/50Hz)
21 - 22 Ciฤ…gล‚a wentylacja
21 - 23 Ogrzewanie/chล‚odzenie
24 - 25 Dioda sygnalizacji awarii
25 - 26 Styk resetowania
+ - 0-10Vdc (Ogrzewanie/chล‚odzenie)
11 - 12 Zewnฤ™trzny czujnik temperatury
A - B MODBUS RTU (R ground)
RJ 45 connector Internet / Modbus TCP/IP
13 - 14 Kontakt zewnฤ™trzny wentylatora
Uwaga: Wysokie napiฤ™cie pod zaciskami N, L, 13, 14, 21, 22, 23, 24, 25 i 26
Sterownika PinTherm Connect uลผywaฤ‡ moลผna tylko do sterowania urzฤ…dzeniami speล‚niajฤ…cymi wy-
mogi dotyczฤ…ce bezpieczeล„stwa zgodnie z normฤ… EN-IEC 61010-1.
PinTherm Connect
06.29.108
PN
DZIEN
08:01 18ยบC
X:060
OK
RESET
ESC
0
I
7272
Citiลฃi๎€ƒacest๎€ƒdocument๎€ƒรฎnainte๎€ƒde
a๎€ƒรฎncepe๎€ƒinstalarea๎€ƒลŸi๎€ƒoperarea
Avertisment!
Instalarea, setarea, modi๎ƒ€carea, repararea sau รฎntreลฃinerea incorectฤƒ poate duce la daune
materiale sau la rฤƒniri. Toate activitฤƒลฃile trebuie efectuate de cฤƒtre personal cali๎ƒ€cat, aprobat.
Dacฤƒ dispozitivul nu este aลŸezat conform instrucลฃiunilor, garanลฃia va ๎ƒ€ anulatฤƒ. Acest aparat nu
este destinat utilizฤƒrii de cฤƒtre copii sau persoane cu un handicap ๎ƒ€zic, senzorial sau mintal, sau
care nu au experienลฃa necesarฤƒ, cu excepลฃia cazurilor รฎn care sunt supravegheate, sau au fost
instruite sฤƒ foloseascฤƒ aparatul, de cฤƒtre o persoanฤƒ responsabilฤƒ cu siguranลฃa lor. Copiii trebuie
supravegheaลฃi, pentru a vฤƒ asigura cฤƒ nu se joacฤƒ cu aparatul.
73
RO
1.0 Cuprins
2.0๎€ƒ Informaลฃii๎€ƒgenerale๎€ƒ
2.1 Modi๎ƒ€cฤƒri pagina 4
2.2 Atenลฃionฤƒri generale pagina 4
3.0 Detalii tehnice
3.1 Detalii tehnice PinTherm Connect pagina 4
3.2 Detalii tehnice pentru senzor de camerฤƒ extern (optional) pagina 5
3.3 Tabel rezistenลฃฤƒ senzor glob extern (optional) pagina 5
3.4 Setฤƒrile din fabricฤƒ pentru PinTherm Connect pagina 5
4.0 Instalarea
4.1 Informaลฃii generale pagina 6
4.2 Asamblarea PinTherm Connect pagina 6
4.3 Asamblarea senzorului glob extern pagina 6
5.0 Manual depanare
5.1 Explicarea butoanelor ลŸi LED-urilor pagina 7
5.2 Explicarea a๎ƒ€ลŸajului pagina 8
5.3 Operarea iniลฃialฤƒ a PinTherm Connect pagina 8
5.4 Activarea meniului utilizatorului pagina 9
5.5 Introducere/schimbare orฤƒ pagina 9
5.6 Schimbarea temperaturilor pentru zi/noapte pagina 10
5.7 Schimbarea orei ลŸi datei pagina 10
5.8 Setari de vacanta pagina 10
5.9 Schimbaลฃi codul de meniu pagina 10
5.10 Schimbare limbฤƒ pagina 11
5.11 Calibrare pagina 11
5.12 Incalzire/racire pagina 11
5.13 Diferenta de comutare pagina 12
5.14 Schimbarea semnalului de control minim pagina 12
5.15 Schimbarea semnalului de control maxim pagina 12
5.16 Schimbati intervalul de semnal de control pagina 12
5.17 Modbus pagina 13
5.18 Informatii Ethernet pagina 13
5.19 Setari IP pagina 13
5.20 Pornire/oprire timp suplimentar pagina 13
5.21 Porniti functia de stergere a cosului de fum pagina 14
5.22 Setฤƒrile din fabricฤƒ pentru PinTherm Connect pagina 14
6.0 Aruncarea PinTherm Connect pagina 14
7.0 Modbus pagina 14
8.0๎€ƒ๎€ƒPosibilitฤƒลฃi๎€ƒde๎€ƒcablaj๎€ƒpentru๎€ƒPinTherm๎€ƒConnect pagina 15
Anexa๎€ƒI๎€ƒ๎€ƒ๎€ƒ Schiลฃฤƒ๎€ƒcablaj pagina 87
Anexa II Modbus pagina 94
74
2.0๎€ƒ Informaลฃii๎€ƒgenerale
2.1 Modi๎ƒ€cฤƒri
Producฤƒtorul se angajeazฤƒ sฤƒ-ลŸi รฎmbunฤƒtฤƒลฃeascฤƒ constant produsele ลŸi รฎลŸi rezervฤƒ dreptul de
a aduce modi๎ƒ€cฤƒri รฎn speci๎ƒ€caลฃii fฤƒrฤƒ noti๎ƒ€care prealabilฤƒ. Detaliile tehnice se presupun a ๎ƒ€
corecte, รฎnsฤƒ nu stau la baza unui contract sau a unei garanลฃii. Toate comenzile sunt acceptate
รฎn conformitate cu termenii standard ai condiลฃiilor noastre de vรขnzare ลŸi livrare (disponibile la
cerere).
2.2 Atenลฃionฤƒri generale
Instalarea trebuie sฤƒ ๎ƒ€e conformฤƒ reglementฤƒrilor locale ลŸi/sau naลฃionale. PinTherm Connect
trebuie aลŸadar instalat de cฤƒtre un instalator competent ลŸi cali๎ƒ€cat, conform legislaลฃiei naลฃionale
ลŸi internaลฃionale. รŽn eventualitatea unei instalฤƒri, calibrฤƒri, modi๎ƒ€cฤƒri, รฎntreลฃineri sau reparฤƒri
incorecte, garanลฃia va ๎ƒ€ anulatฤƒ.
Opriti intotdeauna sursa de alimentare de 230 V inainte de a conecta terminalele. Tensiunea de
alimentare din PinTherm Connect trebuie sa poata ๎ƒ€ oprita intr-un mod dublu cu ajutorul unui
intrerupฤƒtor permanent care este adecvat pentru 250VAC / 10A si respecta reglementarile de
sigurantata aplicabile.
Doar dispozitivele care respectฤƒ EN-IEC 61010-1 pot ๎ƒ€ operate cu PinTherm Connect. Curatati
carcasa PinTherm Connect cu o carpa umeda. Nu aplicati solventi.
Nu exista cerinte privind ventilatia in imediata vecinatate a controlerului.
Atentie - risc de electrocutare.
Atentie - avertizare generala, risc de pericol.
Pot exista tensiuni pe terminalele de conectare unde este amplasat a.
3.0 Detalii tehnice
3.1 Detalii tehnice PinTherm Connect
โ€ข Nume tip : PinTherm Connect
โ€ข Numฤƒr articol : 06 29 108
โ€ข Alimentare electricฤƒ : 90 โ€“ 240 VAC / 47-63Hz
โ€ข Consum propriu : < 9W
โ€ข Ceas : 24 ore cu schimbare automatฤƒ orฤƒ de varฤƒ/iarnฤƒ
โ€ข Programe de comutare : 3 programe de comutare pe zi
โ€ข Diferenta de comutare : 0,1 - 3K
โ€ข Dimensiuni : 166 x 160 x 106mm (Lxlxรฎ)
โ€ข Greutate : 880 grame
โ€ข Grad de protecลฃie : IP-54
โ€ข Mediu de instalare : Transport / depozitare: -20 ยฐ C pana la + 70 ยฐ C.
Operational: -10 ยฐ C pana la + 60 ยฐ C
Umiditatea relativa a aerului: 0-90% fara condensare
Instalare maxima la 2000 metri deasupra nivelului marii.
โ€ข Categorie de tensiune superioara : 11
โ€ข Nivel poluare : 2
โ€ข Schimbati contactul (contactele)* : Incalzire: 230Vac/16A (4A)
Altele: 230Vac/10A (2,5A)
โ€ข Setarea temperaturii : 0 pana la 39 ยฐ C la 1 ยฐ C reglabil
!
!
75
RO
โ€ข Timer ore suplimentare : reglabil 1, 2 sau 3 ore (060, 120, 180)
โ€ข Calibrarea : reglabil de la -3,5 ยฐ C pana la + 3,5 ยฐ C
โ€ข Incalzire/Racire : Contact reversibil pentru incalzire sau racire
โ€ข 0-10 VDC : Iesire 0-10 VDC pentru incalzire sau racire
โ€ข Senzor : Senzor extern de camera (06 29 086)
โ€ข Opลฃiuni limbฤƒ : NL/EN/DE/FR/PL/RO/LT
โ€ข Fuse : 6A
* Contactele releului sunt comutatoare functionale, nu intrerupatoare de siguranta.
3.2 Detalii tehnice pentru senzor extern de camera (optional)
โ€ข Nume tip : RSTF NTC4,7K
โ€ข Numฤƒr articol : 06 29 086
โ€ข Rezistenลฃฤƒ : NTC 4K7
โ€ข Dimensiuni : 79 x 81 x 26mm (Lxlxรฎ)
โ€ข Greutate : 46 grame
โ€ข Racord electric : 0.75 -1.5mmยฒ
โ€ข Grad de protecลฃie : IP-30
3.3 Tabel rezistenลฃฤƒ senzor glob extern
-15ยฐC -10ยฐC -5ยฐC 0ยฐC 5ยฐC 10ยฐC 15ยฐC
32.937kโ„ฆ 25.217kโ„ฆ 19.392kโ„ฆ 15.040kโ„ฆ 11.743kโ„ฆ 9.241kโ„ฆ 7.330kโ„ฆ
20ยฐC 25ยฐC 30ยฐC 35ยฐC 40ยฐC 45ยฐC 50ยฐC
5.855kโ„ฆ 4.700kโ„ฆ 3.777kโ„ฆ 3.071kโ„ฆ 2.512kโ„ฆ 2.066kโ„ฆ 1.709kโ„ฆ
3.4 Setฤƒrile din fabricฤƒ pentru PinTherm Connect
โ€ข Cod meniu : 1000
โ€ข Schimbarea orelor : MON, TUE, WED, THUR, FRI (LU, MA, MI,
JOI, VI) orele 07:30-17:30
SAT, SUN (Sร‚M, DUM) orele 00:00-00:00
โ€ข Temperatura camerei : Temperaturฤƒ zi18ยฐC
Temperaturฤƒ noapte 08ยฐC
โ€ข Calibrare : +0.0
โ€ข Diferenta de comutare : 1K
โ€ข Incalzire/Racire : Incalzire
โ€ข 0-10V range : 1K
โ€ข 0-10V min : 0V
โ€ข 0-10V max : 10V
โ€ข Modbus : Slave ID 001
โ€ข Setari IP : Static
76
4.0 Instalarea
4.1 Informaลฃii generale
รŽnainte de a despacheta PinTherm Connect, veri๎ƒ€caลฃi dacฤƒ nu este deteriorat, aparatul ลŸi senzorii
furnizaลฃi รฎmpreunฤƒ cu acesta. Asiguraลฃi-vฤƒ cฤƒ tipul/modelul ลŸi voltajul sunt corecte.
4.2 Asamblarea PinTherm Connect
Stabiliลฃi un loc corespunzฤƒtor pentru asamblarea PinTherm Connect. Montati PinTherm Connect
pe o suprafata solida care poate suporta minim 4 kg. Este recomandabil ca PinTherm
Connect sฤƒ ๎ƒ€e plasat la o distanลฃฤƒ de ยฑ1,5m de podea, intr-un loc bine accesibil.
Pentru cablurile de etansare utilizati numai cabluri de etansare prevazute cu izolatie de tensiune,
cu o clasa minima de incendiu UL94V2. รŽnainte de a efectua cablajul, veri๎ƒ€caลฃi dacฤƒ alimentarea
este opritฤƒ. รŽn caz contrar, opriลฃi alimentarea รฎnainte de a continua. Dacฤƒ alimentarea este opritฤƒ
pentru aparatul care urmeazฤƒ a ๎ƒ€ conectat, trebuie sฤƒ consultaลฃi manualul tehnic/de depanare al
dispozitivului.
Conectaลฃi PinTherm Connect conform uneia dintre schiลฃele electrice furnizate la ๎ƒ€nalul acestui
manual tehnic. Pentru a selecta schema de cablaj corectฤƒ, trebuie sฤƒ cunoaลŸteลฃi tipul aparatului la
care veลฃi conecta PinTherm Connect. Vezi de asemenea Anexa I pentru o selecลฃie.
Atunci cand se aplica un semnal 0-10VDC, vezi tabelul de mai jos pentru a a๎ƒa diametrul corect al
cablului.
Diametru Lungime
0.8mm
2
80 metri
1.0mm
2
100 metri Este recomandatฤƒ folosirea unui cablu protejat.
1.5mm
2
150 metri
4.3 Asamblarea senzorului glob extern
Plasaลฃi senzorul glob extern รฎntr-un loc ferit de curent, lรขngฤƒ dispozitiv, la o รฎnฤƒlลฃime de aprox. 1,5
m de podea ลŸi conectaลฃi senzorul la terminalele identi๎ƒ€cate รฎn acest scop รฎn PinTherm Connect.
Vezi tabelul de mai jos pentru a a๎ƒa diametrul corect al cablului.
Diametru Lungime
0.8mm
2
80 metri
1.0mm
2
100 metri Este recomandatฤƒ folosirea unui cablu protejat.
1.5mm
2
150 metri
77
RO
5.0 Manual depanare
5.1 Explicarea butoanelor ลŸi LED-urilor
A - A๎ƒ€ลŸaj iluminat (vezi ลŸi 5.2)
B - Buton pentru pornirea sau oprirea cฤƒldurii
C - LED-ul se aprinde cรขnd funcลฃia de รฎncฤƒlzire este pornitฤƒ
D - Buton pentru pornirea sau oprirea poziลฃiei mare
E - LED-ul se aprinde cรขnd funcลฃia este setatฤƒ pe mare
F - Buton pentru deblocarea instalaลฃiei รฎn eventualitatea unei erori (de arzฤƒtor de gaz)
G - LED-ul se aprinde รฎn eventualitatea unei erori (de arzฤƒtor de gaz)
H - Buton pentru activarea meniului utilizatorului sau pentru comutarea la numฤƒrul urmฤƒtor
I - Buton pentru con๎ƒ€rmarea unei selecลฃii/modi๎ƒ€cฤƒri fฤƒcute sau pentru comutarea la urmฤƒtorul
articol din meniu
J - Buton pentru pฤƒrฤƒsirea meniului sau setare fฤƒrฤƒ a efectua vreo modi๎ƒ€care
K - Buton pentru pornirea sau oprirea temporizatorului pentru ore suplimentare
L - Buton ๏€ต+๏€ถ โ€“ pentru modi๎ƒ€carea unei setฤƒri
M - LED-ul se aprinde cรขnd cฤƒldura necesarฤƒ este รฎn poziลฃia รฎncฤƒlzire (arzฤƒtor de gaz pornit)
N - LED-ul se aprinde de ๎ƒ€ecare datฤƒ cรขnd dispozitivul funcลฃioneazฤƒ รฎn poziลฃie mare
O - LED-ul se aprinde cรขnd funcลฃia temporizator pentru ore suplimentare este pornitฤƒ
C
OK
PinTherm Connect
06.29.108
LU
ZI
08:01
E
G
M
N
O
D
F
J K LI
A
B
H
RESET
ESC
0
I
18ยบC
X:060
78
5.2 Explicarea a๎ƒ€ลŸajului
A - A๎ƒ€ลŸeazฤƒ ziua din sฤƒptฤƒmรขnฤƒ
B - Aici este a๎ƒ€ลŸatฤƒ ora exactฤƒ
C - Indicฤƒ temperatura (ยฐC) mฤƒsuratฤƒ
D - Indicฤƒ numฤƒrul de minute รฎnainte ca funcลฃia temporizator ore suplimentare sฤƒ
๎ƒ€e opritฤƒ din nou, iar PinTherm Connect se ajusteazฤƒ la temperatura de noapte
E - Indicฤƒ faptul cฤƒ PinTherm Connect este รฎn poziลฃia zi (DAY) sau noapte (NIGHT)
ลŸi este ajustat รฎn funcลฃie de temperatura de zi sau de noapte
5.3 Operarea iniลฃialฤƒ a PinTherm Connect
Cรขnd setaลฃi voltajul pentru PinTherm Connect pentru prima oarฤƒ, vi se va cere sฤƒ selectaลฃi limba
necesarฤƒ, iar apoi setaลฃi ora ลŸi data. Apoi PinTherm Connect se va รฎntoarce la ecranul principal.
Opลฃiuni limbฤƒ: NL, EN, DE, FR, PL, RO, LT
C
LU
ZI
08:01
E
D
B
A
18ยบC
X:060
SELECT LANGUAGE SA 01-01-2006
00:00:00
16ยฐCLU
ZI
08:00
merge la numarul
semnalului luminos
schimba numarul urmator
selectati limba
necesara
OK OK
ENGLISH
79
RO
5.4 Activarea meniului utilizatorului
Puteลฃi schimba urmฤƒtoarele setฤƒri din meniu:
โ€“ Introduce/schimbฤƒ orele
โ€“ Schimbaลฃi temperaturฤƒ zi/noapte
โ€“ Schimbaลฃi ora/data
โ€“ Setari de vacanta
โ€“ Schimbaลฃi codul de meniu
โ€“ Schimbaลฃi limba
โ€“ Calibrare
โ€“ 0-10V min 0-5V
โ€“ 0-10V max 5-10V
โ€“ 0-10V range (1-3)
โ€“ Modbus
โ€“ Setari IP
5.5 Introducere/schimbare orฤƒ
CODUL
parasiti meniul si รฎntoarceti-va
la ecranul principal
Cod meniu setare din
fabrica
1000
16ยฐCLU
ZI
08:01
merge la numarul
semnalului luminos
schimba numarul urmator
selectati meniul necesar
ESC
OK OK
0000
SETEAZA/SCHIMBA
PROGRAMUL
LUNI
etc.
รฎnapoi la
meniu
merge la numarul
semnalului luminos
schimba numarul urmator
OK
OK
OK
07:30 -> 17:00
SETEAZA/SCHIMBA
PROGRAMUL
LUNI
OK
--:-- -> --:--
merge la numarul
semnalului luminos
schimba numarul urmator
OK
12
LUNI
--:-- -> --:--
3 MARTI
07:30 -> 17:00
1 DUMINICA
--:-- -> --:--
3
80
5.6 Schimbarea temperaturilor pentru zi/noapte
5.7 Schimbarea orei ลŸi datei
5.8 Setari de vacanta
In timpul blocului de timp stabilit, comanda se va regla in functie de temperatura de noapte.
5.9 Schimbaลฃi codul de meniu
MOD VACANT ACTIV
PORNI
รฎnapoi la
meniu
selectati
selectati sau
dezactivati
OK OK
SETARI VACANTA
DE LA: 01-07-2017
LA: 01-08-2017
OK
merge la numarul
semnalului luminos
schimba numarul urmator
18ยฐC
TEMP. ZIUA
TEMP. NOAPTE
selectati
รฎnapoi la
meniu
merge la numarul meniu
semnalului luminos
schimba numarul urmator
merge la numarul
semnalului luminos
schimba numarul urmator
OK OK
OK
08ยฐC
SETEAZA/SCHIMBA
TEMPERATURA
LU 23-03-2009
09:10:00
รฎnapoi la
meniu
selectati
merge la numarul
semnalului luminos
schimba numarul urmator
OK OK
MODIFICA
ORA/DATA
1000
MODIFICA CODUL
SELECTATI COD
noul cod de meniu
รฎnapoi la
meniu
selectati
merge la numarul
semnalului luminos
schimba numarul urmator
OK OK
81
RO
5.10 Schimbare limbฤƒ
Opลฃiuni limbฤƒ: NL, EN, DE, FR, PL, RO, LT.
5.11 Calibrare
Dacฤƒ locul asamblฤƒrii nu este corespunzฤƒtor pentru senzorul extern, este posibil ca temperatura
mฤƒsuratฤƒ de PinTherm Connect sฤƒ nu ๎ƒ€e corectฤƒ. Aceastฤƒ diferenลฃฤƒ de temperaturฤƒ poate ๎ƒ€
compensatฤƒ prin setarea unei valori de corecลฃie cu aceastฤƒ funcลฃie de calibrare.
Exemplu: temperatura mฤƒsuratฤƒ este de 18ยฐC, ecranul de pe PinTherm Connect indicฤƒ 20ยฐC.
AลŸadar diferenลฃa din acest exemplu este de 2ยฐC mai mare - valoarea de corecลฃie trebuie
sฤƒ ๎ƒ€e aลŸadar setatฤƒ la -2ยฐC.
5.12 Incalzire/Racire
Setarea pentru a face controlerul potrivit pentru controlul Incalzirii sau racirii.
INCALZIRE/RACIRE
INCALZIRE
รฎnapoi la
meniu
selectati
schimbare setari
OK
INCALZIRE/RACIRE
OK
ROMAN
SELECTATI LIMBA
รฎnapoi la
meniu
selectati limba
necesara
selectati
OK OK
MODIFICA LIMBA
CALIBREAZA TEMP CALIBREAZA TEMP
Valorea de corectie poate fi ajustata de
รฎnapoi la
meniu
selectati
merge la numarul
semnalului luminos
schimba numarul urmator
OK OK
+ 0.0ยฐC
la -3,5ยฐC la +3,5ยฐC
82
5.13 Diferenta de comutare
Reglabil intre 0.1 si 3.0 K.
5.14 Schimbarea semnalului de control minim
Nota:
Atunci cand nu exista nicio cerere de caldura, PinTherm Connect trimite un semnal de 0VDC.
5.15 Schimbarea semnalului de control maxim
5.16 Schimbati intervalul de semnal de control
Aceasta functie determina cand semnalul 0 - 10VDC este modulat inapoi in conditii de solicitare
de caldura. Cand este setat la 1.0, PinTherm Connect va incepe sa moduleze semnalul 0-10V la 1K
sub temperatura tinta.
Intervalul poate ๎ƒ€ setat intre 0.5 - 3.0 si este setat la 1.0 ca standard.
SCHIMBARE DIF.
1.0K
รฎnapoi la
meniu
selectati
merge la numarul meniu
semnalului luminos
OK
SCHIMBARE DIF.
OK
selectati
schimbare setari
OK OK
0-10V min(0-5V)
2.0 V
0-10V min(0-5V)
รฎnapoi la
meniu
selectati
schimbare setari
OK OK
0-10V max(5-10V)
10.0 V
0-10V max(5-10V)
รฎnapoi la
meniu
รฎnapoi la
meniu
selectati
schimbare setari
OK OK
0-10V Range(1-3)
1.0
0-10V Range(1-3)
83
RO
5.17 ModBus
ID sclav: ajustabil 1 - 247
Setare de fabrica: 1
5.18 Informatii Ethernet
A๎ƒ€sati adresa IP setata.
5.19 Setari IP
DHCP - adresa IP de atribuire automata
Static - setati adresa IP ๎ƒ€xa
Masca SUBnet
5.20 Pornire/oprire timp suplimentar
Cu aceastฤƒ funcลฃie, este posibil sฤƒ comutaลฃi manual 1, 2 sau 3 ore la temperatura pe
timp de zi รฎn afara timpilor de schimbare setaลฃi.
LED-ul galben cu simbolul se va aprinde, indicรขnd faptul cฤƒ funcลฃia este pornitฤƒ.
Va ๎ƒ€ de asemenea indicat pe a๎ƒ€ลŸajul de sub timpul rฤƒmas รฎn minute รฎnainte ca funcลฃia sฤƒ
se dezactiveze din nou, iar PinTherm Connect va opera din nou la temperaturฤƒ pe timp de
noapte. รŽntre timp, funcลฃia poate ๎ƒ€ de asemenea dezactivatฤƒ din nou apฤƒsรขnd butonul
pรขnฤƒ cรขnd LED-ul galben se stinge, iar numฤƒrul de minute nu mai este indicat pe a๎ƒ€ลŸaj.
ADRESA IP
192.168.001.100
รฎnapoi la
meniu
selectati
OK OK
INFORMATII
ETHERNET
ADRESA MAC
5410EC220037
OK
MOD IP
STATIC
รฎnapoi la
meniu
selectati
OK OK
SETARI IP
ADRESA IP
192.168.001.100
OK
schimbare setari
merge la numarul meniu
semnalului luminos
schimba numarul urmator
MASCA SUBNET
255.255.255.000
merge la numarul meniu
semnalului luminos
schimba numarul urmator
SETARI MODBUS
001
รฎnapoi la
meniu
selectati
merge la numarul
semnalului luminos
OK
SETARI MODBUS
OK
schimba numarul urmator
84
Vezi imaginea de mai jos.
5.21 Porniti functia de stergere a cosului de fum
Puteti utiliza aceasta functie pentru a comuta temporar aparatul la iesirea termica completa /
iesirea partiala a caldurii astfel incat sa se poata efectua masuratori. Consultati informatiile de mai
jos pentru instructiuni despre cum sa activati sau sa dezactivati aceasta functie. Dupa activare,
aceasta functie ramane activa timp de 15 minute si se va opri automat dupa aceasta perioada.
5.22 Setฤƒrile din fabricฤƒ pentru PinTherm Connect
Dacฤƒ folosiลฃi aceastฤƒ funcลฃie, toate setฤƒrile din fabricฤƒ vor ๎ƒ€ re-setate. Aceastฤƒ funcลฃie
poate ๎ƒ€ activatฤƒ oricรขnd. Vezi imaginea de mai jos.
6.0 Aruncarea PinTherm Connect
De ๎ƒ€ecare datฤƒ cรขnd PinTherm Connect este รฎnlocuit sau รฎndepฤƒrtat, trebuie reciclat sau casat
conform reglementฤƒrilor naลฃionale ลŸi/sau locale รฎn vigoare.
7.0 Modbus
- Comunicare [12]
- Lista Modbus [13]
Aceasta opreste functia si va duce inapoi la
ecranul principal
ESC
0-10V
10V
14:59
apasati pentru a creste tensiunea (maxim 10V)
Folositi butoanele de mai jos pentru ca aparatul sa
func
tioneze la o tensiune mai mica (reduceti puterea de
caldura)
apasati pentru a reduce tensiunea
T
ineti apasat timp
de +/- 12 secunde
0
NOAPTE
LU
X:060
18ยฐC
LU
ZI
17:01
X:120
LU
ZI
17:01
X:180
LU
ZI
17:01
17:01
18ยฐC
18ยฐC
18ยฐC
tineti apasat timp
de ยฑ 12 secunde
SELECT LANGUAGE
16ยฐCLU
ZI
08:01
prin eceasta, va รฎntoarceti la
principal. Lar valorile din
fabrica nu vor fi re-setate!
OK OK
ESC
ENGLISH
SETARI IMPLICITE
SETATE!
REVENITI LA
IMPLICITE
85
RO
8.0๎€ƒPosibilitฤƒลฃi๎€ƒde๎€ƒcablaj๎€ƒpentru๎€ƒPinTherm๎€ƒConnect
L N Terminale de conectare (230Vac/50Hz)
21 - 22 Ventilatie continua
21 - 23 Incalzire/Racire
24 - 25 Semnal de defectiune
25 - 26 Resetare
+ - 0-10Vdc (Incalzire/Racire)
11 - 12 Senzor extern de camera
A - B MODBUS RTU (R ground)
RJ 45 connector Internet / Modbus TCP/IP
13 - 14 Contact ventilator extern
Atentie: Tensiune periculoasa prezenta la N, L, 13, 14, 21, 22, 23, 24, 25 ลŸi 26
Cu PinTherm Connect, pot ๎ƒ€ controlate numai dispozitivele care respecta normele de siguranta
prevazute รฎn EN-IEC 61010-1.
PinTherm Connect
06.29.108
LU
ZI
08:01 18ยบC
X:060
OK
RESET
ESC
0
I
86
Select the right drawing! Drawing Page
Der richtigen schaltplan Wรคhlen! Schaltplan Seite
Choisir schema electrique! Schematique Page
Kies het juiste elektrische schema! Schema Pagina
๎€ƒ Wybierz๎€ƒschemat๎€ƒ Schemat Strona
Selectati schema corecta! Schema Pagina
EN
DE
FR
NL
PL
RO
4x
GS+ [1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
[10]
[11] 93
91
90
89
88
87
OK
RESET
ESC
0
I
PinTherm Connect
06.29.108
MON
DAY
08:01
X:060
18ยบC
06 29 108
GSX
Fร–HN
TANNER MDA 230V
TANNER MDA EC
ECOFAN W42/W82/W142
ECOFAN W42/W82/W142 EC
MDV BLUE EC 230V
MDV BLUE EC 400V
92
87
WS TT F1
Isolator switch Black bulb sensor Fuse
Reparatur schalter Schwarze kugel fรผhler Sicherung
Lโ€™interrupteur de proximitรฉ Capteur globe noir Fusible
Werkschakelaar Zwarte bol voeler Zekering
Wyล‚acznik serwisowy Czujnik Czarna kula Bezpiecznik
Switch pentru izolare Senzor glob Fitil
[1]
[2]
EN
DE
FR
NL
PL
RO
๏€ ๏€‚ ๏€ƒ ๏€„ ๏€… ๏€† ๏€‡ ๏€ˆ ๏€‰ ๏€Š ๏€‚๏€ ๏€‚๏€‚ ๏€‚๏€ƒ ๏€‚๏€„ ๏€‚๏€… ๏€‚๏€† ๏€‚๏€‡ ๏€‚๏€ˆ ๏€‚๏€‰ ๏€‚๏€Š
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€”๏€•๏€๏€๏€๏€–๏€—
๏€˜๏€๏€—๏€™
๏€˜๏€๏€–๏€™
๏€˜๏€ฅ๏€ฏ
๏€Ÿ๏€™๏€ ๏€™
๏€Ž๏€ก๏€œ
๏€œ๏€š๏€—๏€ข๏€’
๏€ฃ๏€•๏€‘๏€’
๏€‚๏€ค๏€†๏€ค๏€ƒ๏€๏€‚๏€‰
๏€ฅ๏€–๏€๏€š๏€ฆ๏€—๏€ง๏€ฆ๏€š๏€๏€ค
๏€๏€ข๏€’๏€’๏€๏€‘
๏€˜๏€‘๏€ข๏€ง๏€ง๏€
๏€๏€‘๏€—๏€™๏€๏€‘
๏€Ž๏€๏€๏€‘๏€’๏€•๏€จ๏€—๏€š๏€—๏€จ ๏€Ž๏€ฉ๏€ง๏€
๏€ž๏€๏€‘๏€จ๏€Œ๏€•๏€
๏€Ž๏€ช๏€ค๏€๏€‡๏€ƒ๏€Š๏€‚๏€๏€‰
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’
๏€‚๏€™๏€
๏€…๏€
๏€†๏€
๏€…๏€‚
๏€Œ๏€“๏€๏€“๏€๏€“๏€•๏€“๏€ก๏€“๏€š๏€“๏€—๏€“๏€Œ๏€“๏€ก๏€“๏€๏€“๏€ช๏€“๏€š๏€“๏€ฆ๏€“๏€ฆ๏€“๏€๏€“๏€๏€“๏€๏€“๏€๏€“๏€Œ๏€“๏€ซ๏€“๏€ข๏€“๏€๏€“๏€ฌ
๏€ญ
๏€ฎ๏€ ๏€ญ ๏€ฏ ๏€ค ๏€‚๏€‚ ๏€‚๏€ƒ ๏€ฐ๏€ฃ
๏€ƒ๏€ƒ๏€ƒ๏€‚
๏€ƒ๏€…๏€ƒ๏€„
๏€ƒ๏€‡๏€ƒ๏€†
๏€‚๏€…๏€‚๏€„
๏€‚๏€ต๏€ƒ๏€„๏€๏€ž๏€“๏€ฏ๏€“๏€‹๏€ฒ๏€ณ๏€†๏€๏€ช๏€ซ
๏€„๏€…
๏€Ž๏€ช๏€ค๏€๏€‡๏€ƒ๏€Š๏€‚๏€๏€‰ ๏€ณ๏€ณ ๏€‚๏€™๏€๏€…๏€‚ ๏€ณ๏€ณ
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€–๏€•๏€๏€๏€๏€–๏€—๏€“๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€‚๏€๏€‰ ๏€˜๏€ฅ๏€ฏ
๏€›๏€•๏€น๏€ฎ๏€ข๏€จ๏€Ž๏€”๏€‹๏€ณ๏€บ๏€‹
๏€‚๏€ƒ
๏€ฃ๏€Ž๏€”๏€“๏€…๏€ถ๏€ˆ๏€ท
๏€‚
๏€ƒ
๏€ญ๏€ธ
๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€๏€‰๏€‡
๏€Ž๏€Ž
๏€ฃ๏€ฐ ๏€‹๏€ฒ
๏€Ž๏€Ž ๏€ค ๏€ฒ๏€ธ๏€—๏€๏€‘๏€๏€๏€“๏€‘๏€ข๏€Œ๏€’๏€—๏€๏€ก๏€•๏€๏€ฆ๏€๏€‘
๏€ ๏€๏€‘๏€ป๏€จ๏€–๏€๏€š๏€ป๏€๏€ฆ๏€š๏€š๏€‘๏€ ๏€ฅ ๏€ค
๏€ฑ๏€๏€ป๏€๏€‘๏€Œ๏€๏€ฌ๏€ผ๏€‚ ๏€ค
๏€ฐ๏€‚๏€ฃ๏€‹๏€ฒ
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€”๏€•๏€๏€๏€๏€–๏€—๏€“๏€“๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€‚๏€๏€‰
๏€˜๏€ฅ๏€ฏ
๏€ผ๏€‚
๏€‡๏€
๏€บ๏€ฃ๏€Ž๏€ฒ๏€ญ๏€ผ๏€๏€”๏€ฒ๏€ฏ
๏€›๏๏€œ๏€ด๏€ฐ๏€ฒ
๏€”๏๏€ฃ๏€ฃ๏€ฒ๏€”๏€Ž๏€บ๏๏€ฃ๏€“๏€ฎ๏๏„๏€“๏€˜๏€ฅ๏€ฏ๏€ณ๏€˜๏€ฅ๏„๏€“๏€„๏€๏€™๏€๏€…๏€™๏€…๏€†๏€
๏€‚
๏„๏€„
๏€ƒ
๏€…
๏„๏€„
๏€†
๏€‚
๏„๏€‚
๏€ƒ ๏€„ ๏€… ๏€† ๏€‡ ๏€ˆ ๏€‰
๏€ ๏€‚ ๏€ƒ ๏€„ ๏€… ๏€† ๏€‡ ๏€ˆ ๏€‰ ๏€Š ๏€‚๏€ ๏€‚๏€‚ ๏€‚๏€ƒ ๏€‚๏€„ ๏€‚๏€… ๏€‚๏€† ๏€‚๏€‡ ๏€‚๏€ˆ ๏€‚๏€‰ ๏€‚๏€Š
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€”๏€•๏€๏€๏€๏€–๏€—
๏€˜๏€๏€—๏€™
๏€˜๏€๏€–๏€™
๏€˜๏€ฅ๏„
๏€Ÿ๏€™๏€ ๏€™
๏€Ž๏€ก๏€œ
๏€œ๏€š๏€—๏€ข๏€’
๏€ฃ๏€•๏€‘๏€’
๏€‚๏€ค๏€†๏€ค๏€ƒ๏€๏€‚๏€‰
๏€ฅ๏€–๏€๏€š๏€ฆ๏€—๏€ง๏€ฆ๏€š๏€๏€ค
๏€๏€ข๏€’๏€’๏€๏€‘
๏€˜๏€‘๏€ข๏€ง๏€ง๏€
๏€๏€‘๏€—๏€™๏€๏€‘
๏€Ž๏€๏€๏€‘๏€’๏€•๏€จ๏€—๏€š๏€—๏€จ ๏€Ž๏€ฉ๏€ง๏€
๏€ž๏€๏€‘๏€จ๏€Œ๏€•๏€
๏€Ž๏€ช๏€ค๏€๏€‡๏€ƒ๏€Š๏€‚๏€๏€‰
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’
๏€‚๏€™๏€
๏€„๏€
๏€…๏€‚
๏€…๏€
๏€Œ๏€“๏€๏€“๏€๏€“๏€•๏€“๏€ก๏€“๏€š๏€“๏€—๏€“๏€Œ๏€“๏€ก๏€“๏€๏€“๏€ช๏€“๏€š๏€“๏€ฆ๏€“๏€ฆ๏€“๏€๏€“๏€๏€“๏€๏€“๏€๏€“๏€Œ๏€“๏€ซ๏€“๏€ข๏€“๏€๏€“๏€ฌ
๏€ญ
๏€ฎ๏€ ๏€ญ ๏€ฏ ๏€ค ๏€‚๏€‚ ๏€‚๏€ƒ ๏€ฐ๏€ฃ
๏€ƒ๏€ƒ๏€ƒ๏€‚
๏€ƒ๏€…๏€ƒ๏€„
๏€ƒ๏€‡๏€ƒ๏€†
๏€‚๏€…๏€‚๏€„
๏€‚๏€ต๏€ƒ๏€„๏€๏€ž๏€“๏€ฏ๏€“๏€‹๏€ฒ๏€ณ๏€†๏€๏€ช๏€ซ
๏€ฃ๏€ฐ ๏€‹๏€ฒ
๏€Ž๏€ช๏€ค๏€๏€‡๏€ƒ๏€Š๏€‚๏€๏€‰ ๏€ณ๏€ณ ๏€‚๏€™๏€๏€…๏€ ๏€ณ๏€ณ
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€–๏€•๏€๏€๏€๏€–๏€—๏€“๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€‚๏€๏€‰ ๏€˜๏€ฅ๏„
๏€›๏€•๏€น๏€ฎ๏€ข๏€จ๏€Ž๏€”๏€‹๏€ณ๏€บ๏€‹
๏€‚๏€ƒ
๏€ฃ๏€Ž๏€”๏€“๏€…๏€ถ๏€ˆ๏€ท
๏€‚
๏€ƒ
๏€ญ๏€ธ
๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€๏€‰๏€‡
๏€Ž๏€Ž
๏€„๏€…๏€†๏€‡ ๏€„๏€…๏€†๏€‡
๏€’๏€š๏€ธ๏€™๏€“๏€‰๏€“๏€˜๏€ฅ๏„
๏€Ž๏€Ž ๏€ค ๏€ฒ๏€ธ๏€—๏€๏€‘๏€๏€๏€“๏€‘๏€ข๏€Œ๏€’๏€—๏€๏€ก๏€•๏€๏€ฆ๏€๏€‘
๏€ ๏€๏€‘๏€ป๏€จ๏€–๏€๏€š๏€ป๏€๏€ฆ๏€š๏€š๏€‘๏€ ๏€ฅ ๏€ค
๏€ฑ๏€๏€ป๏€๏€‘๏€Œ๏€๏€ฌ๏€ผ๏€‚ ๏€ค
๏€ฐ๏€‚๏€ฃ๏€‹๏€ฒ
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€”๏€•๏€๏€๏€๏€–๏€—๏€“๏€“๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€‚๏€๏€‰
๏€บ๏€ฃ๏€Ž๏€ฒ๏€ญ๏€ผ๏€๏€”๏€ฒ๏€ฏ
๏€›๏๏€œ๏€ด๏€ฐ๏€ฒ
๏€”๏๏€ฃ๏€ฃ๏€ฒ๏€”๏€Ž๏€บ๏๏€ฃ๏€“๏€ฎ๏๏„๏€“๏€˜๏€ฅ๏€ฏ๏€ณ๏€˜๏€ฅ๏„๏€“๏€„๏€๏€™๏€๏€…๏€™๏€…๏€†๏€
๏€‚
๏„๏€„
๏€ƒ
๏€…
๏„๏€„
๏€†
๏€‚
๏„๏€‚
๏€ƒ ๏€„ ๏€… ๏€† ๏€‡ ๏€ˆ ๏€‰
๏€ผ๏€‚
๏€‡๏€
๏€˜๏€ฅ๏„ ๏€˜๏€ฅ๏„
88
[3]
[4]
WS TT F1 Y1
Isolator switch Black bulb sensor Fuse 3-way valve (optional)
Reparatur schalter Schwarze kugel fรผhler Sicherung 3-wege ventil (optional)
Lโ€™interrupteur de proximitรฉ Capteur globe noir Fusible 3-voies vanne (optional)
Werkschakelaar Zwarte bol voeler Zekering 3-wegklep (optioneel)
Wyล‚acznik serwisowy Czujnik Czarna kula Bezpiecznik Zawรณr 3-drogowy (Opcja)
Switch pentru izolare Senzor glob Fitil Supapฤƒ cutrei cฤƒi (Optional)
EN
DE
FR
NL
PL
RO
๏€ ๏€‚ ๏€ƒ ๏€„ ๏€… ๏€† ๏€‡ ๏€ˆ ๏€‰ ๏€Š ๏€‚๏€ ๏€‚๏€‚ ๏€‚๏€ƒ ๏€‚๏€„ ๏€‚๏€… ๏€‚๏€† ๏€‚๏€‡ ๏€‚๏€ˆ ๏€‚๏€‰ ๏€‚๏€Š
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€”๏€•๏€๏€๏€๏€–๏€—
๏€˜๏€๏€—๏€™
๏€˜๏€๏€–๏€™
๏€ผ๏ƒ๏€ช๏€ฃ
๏€Ÿ๏€™๏€ ๏€™
๏€Ž๏€ก๏€œ
๏€œ๏€š๏€—๏€ข๏€’
๏€ฃ๏€•๏€‘๏€’
๏€‚๏€ค๏€†๏€ค๏€ƒ๏€๏€‚๏€‰
๏€ฅ๏€–๏€๏€š๏€ฆ๏€—๏€ง๏€ฆ๏€š๏€๏€ค
๏€๏€ข๏€’๏€’๏€๏€‘
๏€˜๏€‘๏€ข๏€ง๏€ง๏€
๏€๏€‘๏€—๏€™๏€๏€‘
๏€Ž๏€๏€๏€‘๏€’๏€•๏€จ๏€—๏€š๏€—๏€จ ๏€Ž๏€ฉ๏€ง๏€
๏€ž๏€๏€‘๏€จ๏€Œ๏€•๏€
๏€Ž๏€ช๏€ค๏€๏€‡๏€ƒ๏€Š๏€‚๏€๏€‰
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’
๏€‚๏€™๏€
๏€ƒ๏€‚
๏€…๏€
๏€„๏€
๏€Œ๏€“๏€๏€“๏€๏€“๏€•๏€“๏€ก๏€“๏€š๏€“๏€—๏€“๏€Œ๏€“๏€ก๏€“๏€๏€“๏€ช๏€“๏€š๏€“๏€ฆ๏€“๏€ฆ๏€“๏€๏€“๏€๏€“๏€๏€“๏€๏€“๏€Œ๏€“๏€ซ๏€“๏€ข๏€“๏€๏€“๏€ฌ
๏€ญ
๏€ฎ๏€ ๏€ญ ๏€ฏ ๏€ค ๏€‚๏€‚ ๏€‚๏€ƒ ๏€ฐ๏€ฃ
๏€ƒ๏€ƒ๏€ƒ๏€‚
๏€ƒ๏€…๏€ƒ๏€„
๏€ƒ๏€‡๏€ƒ๏€†
๏€‚๏€…๏€‚๏€„
๏„๏€ƒ
๏€‚๏€ƒ๏€„๏€…๏€†๏€‡
๏€Ž๏€ช๏€ค๏€๏€‡๏€ƒ๏€Š๏€‚๏€๏€‰ ๏€ณ๏€ณ ๏€‚๏€™๏€๏€„๏€ ๏€ณ๏€ณ
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€–๏€•๏€๏€๏€๏€–๏€—๏€“๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€‚๏€๏€‰ ๏€ผ๏ƒ๏€ช๏€ฃ
๏€›๏€•๏€น๏€ฎ๏€ข๏€จ๏€Ž๏€”๏€‹๏€ณ๏€บ๏€‹
๏€‚๏€ƒ
๏€ฃ๏€Ž๏€”๏€“๏€…๏€ถ๏€ˆ๏€ท
๏€‚
๏€ƒ
๏€ญ๏€ธ
๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€๏€‰๏€‡
๏€Ž๏€Ž
๏€
๏€ƒ๏€‚
๏€ƒ๏€‚
๏€Ž๏€Ž ๏€ค ๏€ฒ๏€ธ๏€—๏€๏€‘๏€๏€๏€“๏€‘๏€ข๏€Œ๏€’๏€—๏€๏€ก๏€•๏€๏€ฆ๏€๏€‘
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€”๏€•๏€๏€๏€๏€–๏€—๏€“๏€“๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€‚๏€๏€‰
๏€ผ๏ƒ๏€ช๏€ฃ
๏€ ๏€‚ ๏€ƒ ๏€„ ๏€… ๏€† ๏€‡ ๏€ˆ ๏€‰ ๏€Š ๏€‚๏€ ๏€‚๏€‚ ๏€‚๏€ƒ ๏€‚๏€„ ๏€‚๏€… ๏€‚๏€† ๏€‚๏€‡ ๏€‚๏€ˆ ๏€‚๏€‰ ๏€‚๏€Š
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€”๏€•๏€๏€๏€๏€–๏€—
๏€˜๏€๏€—๏€™
๏€˜๏€๏€–๏€™
๏€Ž๏€š๏€๏€๏€๏€‘๏€“๏€›๏€œ๏€๏€“๏€ƒ๏€„๏€๏€ž
๏€Ÿ๏€™๏€ ๏€™
๏€Ž๏€ก๏€œ
๏€œ๏€š๏€—๏€ข๏€’
๏€ฃ๏€•๏€‘๏€’
๏€‚๏€ค๏€†๏€ค๏€ƒ๏€๏€‚๏€‰
๏€ฅ๏€–๏€๏€š๏€ฆ๏€—๏€ง๏€ฆ๏€š๏€๏€ค
๏€๏€ข๏€’๏€’๏€๏€‘
๏€˜๏€‘๏€ข๏€ง๏€ง๏€
๏€๏€‘๏€—๏€™๏€๏€‘
๏€Ž๏€๏€๏€‘๏€’๏€•๏€จ๏€—๏€š๏€—๏€จ ๏€Ž๏€ฉ๏€ง๏€
๏€ž๏€๏€‘๏€จ๏€Œ๏€•๏€
๏€Ž๏€ช๏€ค๏€๏€‡๏€ƒ๏€Š๏€‚๏€๏€‰
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’
๏€‚๏€™๏€
๏€‚๏€‚
๏€‚๏€
๏€Œ๏€“๏€๏€“๏€๏€“๏€•๏€“๏€ก๏€“๏€š๏€“๏€—๏€“๏€Œ๏€“๏€ก๏€“๏€๏€“๏€ช๏€“๏€š๏€“๏€ฆ๏€“๏€ฆ๏€“๏€๏€“๏€๏€“๏€๏€“๏€๏€“๏€Œ๏€“๏€ซ๏€“๏€ข๏€“๏€๏€“๏€ฌ
๏€ญ
๏€ฎ๏€ ๏€ญ ๏€ฏ ๏€ค ๏€‚๏€‚ ๏€‚๏€ƒ ๏€ฐ๏€ฃ
๏€ƒ๏€ƒ๏€ƒ๏€‚
๏€ƒ๏€…๏€ƒ๏€„
๏€ƒ๏€‡๏€ƒ๏€†
๏€‚๏€…๏€‚๏€„
๏€ฎ๏€ญ
๏€Ž๏€ฎ
๏€ฑ๏€ 
๏€ฎ๏€ฐ
๏€˜๏€ฒ๏€ณ๏€˜๏€ญ
๏€ฑ๏€ƒ ๏€ด๏€ƒ ๏€ด๏€‚ ๏€‹๏€ฒ
๏€‚๏€ต๏€ƒ๏€„๏€๏€ž๏€“๏€ฏ๏€“๏€‹๏€ฒ๏€ณ๏€†๏€๏€ช๏€ซ
๏€‚๏€ƒ
๏€ฃ๏€Ž๏€”๏€“๏€…๏€ถ๏€ˆ๏€ท
๏€‚
๏€ƒ
๏€ญ๏€ธ
๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€๏€‰๏€‡
๏€Ž๏€Ž
๏€Ž๏€ช๏€ค๏€๏€‡๏€ƒ๏€Š๏€‚๏€๏€‰ ๏€ณ๏€ณ ๏€‚๏€™๏€๏€‚๏€ ๏€ณ๏€ณ
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€–๏€•๏€๏€๏€๏€–๏€—๏€“๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€‚๏€๏€‰ ๏€Ž๏€๏€ฃ๏€ฃ๏€ฒ๏€ญ๏€“๏€›๏€œ๏€๏€“๏€ƒ๏€„๏€๏€ž
๏€›๏€•๏€น๏€ฎ๏€ข๏€จ๏€Ž๏€”๏€‹๏€ณ๏€บ๏€‹
๏€Ž๏€Ž ๏€ค ๏€ฒ๏€ธ๏€—๏€๏€‘๏€๏€๏€“๏€‘๏€ข๏€Œ๏€’๏€—๏€๏€ก๏€•๏€๏€ฆ๏€๏€‘
๏€ ๏€๏€‘๏€ป๏€จ๏€–๏€๏€š๏€ป๏€๏€ฆ๏€š๏€š๏€‘๏€ ๏€ฅ ๏€ค
๏€ฑ๏€๏€ป๏€๏€‘๏€Œ๏€๏€ฌ๏€ผ๏€‚ ๏€ค
๏€ƒ๏€…๏€ž๏€ณ๏€ƒ๏€„๏€๏€ž
๏€ฐ
๏€ฃ
๏€„๏€ค๏€ฝ๏€๏€ฌ๏€ป๏€ฆ๏€๏€ง๏€“๏€พ๏€•๏€ง๏€—๏€Œ๏€•๏€๏€๏€๏€ฆ๏€ฟ๏€“๏€๏€‚ ๏€ค
๏€ฐ๏€‚๏€ฃ๏€‹๏€ฒ
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€”๏€•๏€๏€๏€๏€–๏€—๏€“๏€“๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€‚๏€๏€‰
๏€‚
๏€ƒ
๏€„
๏€…
๏€ ๏€ฅ
๏€Ž๏€๏€ฃ๏€ฃ๏€ฒ๏€ญ๏€“๏€›๏€œ๏€
๏€ผ๏€‚
๏€‡๏€
๏€๏€‚
89
WS TT F1 Y1
Isolator switch Black bulb sensor Fuse 2 / 3-way valve (optional)
Reparatur schalter Schwarze kugel fรผhler Sicherung 2 / 3-wege ventil (optional)
Lโ€™interrupteur de proximitรฉ Capteur globe noir Fusible 2 / 3-voies vanne (optional)
Werkschakelaar Zwarte bol voeler Zekering 2 / 3-wegklep (optioneel)
Wyล‚acznik serwisowy Czujnik Czarna kula Bezpiecznik Zawรณr 2 / 3-drogowy (Opcja)
Switch pentru izolare Senzor glob Fitil Supapฤƒ 2 / 3 cฤƒi (Optional)
[5]
[6]
EN
DE
FR
NL
PL
RO
๏€ ๏€‚ ๏€ƒ ๏€„ ๏€… ๏€† ๏€‡ ๏€ˆ ๏€‰ ๏€Š ๏€‚๏€ ๏€‚๏€‚ ๏€‚๏€ƒ ๏€‚๏€„ ๏€‚๏€… ๏€‚๏€† ๏€‚๏€‡ ๏€‚๏€ˆ ๏€‚๏€‰ ๏€‚๏€Š
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€”๏€•๏€๏€๏€๏€–๏€—
๏€˜๏€๏€—๏€™
๏€˜๏€๏€–๏€™
๏€Ž๏€š๏€๏€๏€๏€‘๏€“๏€›๏€œ๏€๏€“๏€ƒ๏€„๏€๏€ž
๏€Ÿ๏€™๏€ ๏€™
๏€Ž๏€ก๏€œ
๏€œ๏€š๏€—๏€ข๏€’
๏€ฃ๏€•๏€‘๏€’
๏€‚๏€ค๏€†๏€ค๏€ƒ๏€๏€‚๏€‰
๏€ฅ๏€–๏€๏€š๏€ฆ๏€—๏€ง๏€ฆ๏€š๏€๏€ค
๏€๏€ข๏€’๏€’๏€๏€‘
๏€˜๏€‘๏€ข๏€ง๏€ง๏€
๏€๏€‘๏€—๏€™๏€๏€‘
๏€Ž๏€๏€๏€‘๏€’๏€•๏€จ๏€—๏€š๏€—๏€จ ๏€Ž๏€ฉ๏€ง๏€
๏€ž๏€๏€‘๏€จ๏€Œ๏€•๏€
๏€Ž๏€ช๏€ค๏€๏€‡๏€ƒ๏€Š๏€‚๏€๏€‰
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’
๏€‚๏€™๏€
๏€‚๏€
๏€‚๏€ƒ
๏€‚๏€‚
๏€Œ๏€“๏€๏€“๏€๏€“๏€•๏€“๏€ก๏€“๏€š๏€“๏€—๏€“๏€Œ๏€“๏€ก๏€“๏€๏€“๏€ช๏€“๏€š๏€“๏€ฆ๏€“๏€ฆ๏€“๏€๏€“๏€๏€“๏€๏€“๏€๏€“๏€Œ๏€“๏€ซ๏€“๏€ข๏€“๏€๏€“๏€ฌ
๏€ญ
๏€ฎ๏€ ๏€ญ ๏€ฏ ๏€ค ๏€‚๏€‚ ๏€‚๏€ƒ ๏€ฐ๏€ฃ
๏€ƒ๏€ƒ๏€ƒ๏€‚
๏€ƒ๏€…๏€ƒ๏€„
๏€ƒ๏€‡๏€ƒ๏€†
๏€‚๏€…๏€‚๏€„
๏€‹๏€ฒ ๏€ฃ ๏€ฐ๏€‚
๏€‚๏€ต๏€ƒ๏€„๏€๏€ž๏€“๏€ฏ๏€“๏€‹๏€ฒ๏€ณ๏€†๏€๏€ช๏€ซ
๏€ฎ๏€ญ
๏€Ž๏€ฎ
๏€ฑ๏€ 
๏€ฎ๏€ฐ
๏€˜๏€ฒ๏€ณ๏€˜๏€ญ
๏€ฑ๏€ƒ ๏€ด๏€ƒ ๏€ด๏€‚ ๏€‹๏€ฒ
๏€ฎ๏€ญ
๏€Ž๏€ฎ
๏€ฑ๏€ 
๏€ฎ๏€ฐ
๏€˜๏€ฒ๏€ณ๏€˜๏€ญ
๏€ฑ๏€ƒ ๏€ด๏€ƒ ๏€ด๏€‚ ๏€‹๏€ฒ
๏€Ž๏€ช๏€ค๏€๏€‡๏€ƒ๏€Š๏€‚๏€๏€‰ ๏€ณ๏€ณ ๏€‚๏€™๏€๏€‚๏€‚ ๏€ณ๏€ณ
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€–๏€•๏€๏€๏€๏€–๏€—๏€“๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€‚๏€๏€‰ ๏€Ž๏€๏€ฃ๏€ฃ๏€ฒ๏€ญ๏€“๏€›๏€œ๏€๏€“๏€ƒ๏€„๏€๏€ž
๏€›๏€•๏€น๏€ฎ๏€ข๏€จ๏€Ž๏€”๏€‹๏€ณ๏€บ๏€‹
๏€‚๏€ƒ
๏€ฃ๏€Ž๏€”๏€“๏€…๏€ถ๏€ˆ๏€ท
๏€‚
๏€ƒ
๏€ญ๏€ธ
๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€๏€‰๏€‡
๏€Ž๏€Ž
๏€ƒ๏€…๏€ž๏€ณ๏€ƒ๏€„๏€๏€ž
๏€ฐ
๏€ฃ
๏€Ž๏€Ž ๏€ค ๏€ฒ๏€ธ๏€—๏€๏€‘๏€๏€๏€“๏€‘๏€ข๏€Œ๏€’๏€—๏€๏€ก๏€•๏€๏€ฆ๏€๏€‘
๏€ ๏€๏€‘๏€ป๏€จ๏€–๏€๏€š๏€ป๏€๏€ฆ๏€š๏€š๏€‘๏€ ๏€ฅ ๏€ค
๏€ฑ๏€๏€ป๏€๏€‘๏€Œ๏€๏€ฌ๏€ผ๏€‚ ๏€ค
๏€„๏€ค๏€ฝ๏€๏€ฌ๏€ป๏€ฆ๏€๏€ง๏€“๏€พ๏€•๏€ง๏€—๏€Œ๏€•๏€๏€๏€๏€ฆ๏€ฟ๏€“๏€๏€‚ ๏€ค
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€”๏€•๏€๏€๏€๏€–๏€—๏€“๏€“๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€‚๏€๏€‰
๏€‚
๏€ƒ
๏€„
๏€…
๏€ ๏€ฅ
๏€‚
๏€ƒ
๏€„
๏€…
๏€ ๏€ฅ
๏€Ž๏€๏€ฃ๏€ฃ๏€ฒ๏€ญ๏€“๏€›๏€œ๏€ ๏€Ž๏€๏€ฃ๏€ฃ๏€ฒ๏€ญ๏€“๏€›๏€œ๏€
๏€ผ๏€‚
๏€‡๏€
๏€๏€‚
๏€ ๏€‚ ๏€ƒ ๏€„ ๏€… ๏€† ๏€‡ ๏€ˆ ๏€‰ ๏€Š ๏€‚๏€ ๏€‚๏€‚ ๏€‚๏€ƒ ๏€‚๏€„ ๏€‚๏€… ๏€‚๏€† ๏€‚๏€‡ ๏€‚๏€ˆ ๏€‚๏€‰ ๏€‚๏€Š
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€”๏€•๏€๏€๏€๏€–๏€—
๏€˜๏€๏€—๏€™
๏€˜๏€๏€–๏€™
๏€Ž๏€š๏€๏€๏€๏€‘๏€“๏€›๏€œ๏€๏€“๏€ฒ๏€”
๏€Ÿ๏€™๏€ ๏€™
๏€Ž๏€ก๏€œ
๏€œ๏€š๏€—๏€ข๏€’
๏€ฃ๏€•๏€‘๏€’
๏€‚๏€ค๏€†๏€ค๏€ƒ๏€๏€‚๏€‰
๏€ฅ๏€–๏€๏€š๏€ฆ๏€—๏€ง๏€ฆ๏€š๏€๏€ค
๏€๏€ข๏€’๏€’๏€๏€‘
๏€˜๏€‘๏€ข๏€ง๏€ง๏€
๏€๏€‘๏€—๏€™๏€๏€‘
๏€Ž๏€๏€๏€‘๏€’๏€•๏€จ๏€—๏€š๏€—๏€จ ๏€Ž๏€ฉ๏€ง๏€
๏€ž๏€๏€‘๏€จ๏€Œ๏€•๏€
๏€Ž๏€ช๏€ค๏€๏€‡๏€ƒ๏€Š๏€‚๏€๏€‰
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’
๏€‚๏€™๏€
๏€‚๏€‚
๏€ƒ๏€
๏€‚๏€ƒ
๏€Œ๏€“๏€๏€“๏€๏€“๏€•๏€“๏€ก๏€“๏€š๏€“๏€—๏€“๏€Œ๏€“๏€ก๏€“๏€๏€“๏€ช๏€“๏€š๏€“๏€ฆ๏€“๏€ฆ๏€“๏€๏€“๏€๏€“๏€๏€“๏€๏€“๏€Œ๏€“๏€ซ๏€“๏€ข๏€“๏€๏€“๏€ฌ
๏€ญ
๏€ฎ๏€ ๏€ญ ๏€ฏ ๏€ค ๏€‚๏€‚ ๏€‚๏€ƒ ๏€ฐ๏€ฃ
๏€ƒ๏€ƒ๏€ƒ๏€‚
๏€ƒ๏€…๏€ƒ๏€„
๏€ƒ๏€‡๏€ƒ๏€†
๏€‚๏€…๏€‚๏€„
๏€‚๏€ต๏€ƒ๏€„๏€๏€ž๏€“๏€ฏ๏€“๏€‹๏€ฒ๏€ณ๏€†๏€๏€ช๏€ซ
๏€ฐ๏€‚ ๏€ฃ ๏€‹๏€ฒ๏€˜๏€ฃ๏€œ๏€๏€ค๏€‚๏€๏€ž
๏€Ž๏€ช๏€ค๏€๏€‡๏€ƒ๏€Š๏€‚๏€๏€‰ ๏€ณ๏€ณ ๏€‚๏€™๏€๏€‚๏€ƒ ๏€ณ๏€ณ
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€–๏€•๏€๏€๏€๏€–๏€—๏€“๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€‚๏€๏€‰ ๏€Ž๏€๏€ฃ๏€ฃ๏€ฒ๏€ญ๏€“๏€›๏€œ๏€๏€“๏€พ๏€ฒ๏€”๏€ค๏€ผ๏€๏€ฃ๏€ฟ
๏€›๏€•๏€น๏€ฎ๏€ข๏€จ๏€Ž๏€”๏€‹๏€ณ๏€บ๏€‹
๏€‚๏€ƒ
๏€ฃ๏€Ž๏€”๏€“๏€…๏€ถ๏€ˆ๏€ท
๏€‚
๏€ƒ
๏€ญ๏€ธ
๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€๏€‰๏€‡
๏€Ž๏€Ž
๏€Ž๏€Ž ๏€ค ๏€ฒ๏€ธ๏€—๏€๏€‘๏€๏€๏€“๏€‘๏€ข๏€Œ๏€’๏€—๏€๏€ก๏€•๏€๏€ฆ๏€๏€‘
๏€ ๏€๏€‘๏€ป๏€จ๏€–๏€๏€š๏€ป๏€๏€ฆ๏€š๏€š๏€‘๏€ ๏€ฅ ๏€ค
๏€ฑ๏€๏€ป๏€๏€‘๏€Œ๏€๏€ฌ๏€ผ๏€‚ ๏€ค
๏€ญ๏€๏€ฌ๏€๏€ฆ๏€ป๏€ฆ๏€๏€ง๏€“๏€พ๏€•๏€ง๏€—๏€Œ๏€•๏€๏€๏€๏€ฆ๏€ฟ๏€“๏€๏€‚ ๏€ค
๏€ฐ๏€‚๏€ฃ๏€‹๏€ฒ
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€”๏€•๏€๏€๏€๏€–๏€—๏€“๏€“๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€‚๏€๏€‰
๏€‚
๏€ƒ
๏€ ๏€ฅ
๏€„
๏€…
๏€Ž๏€๏€ฃ๏€ฃ๏€ฒ๏€ญ๏€“๏€›๏€œ๏€๏€“๏€ฒ๏€”
๏€๏€‚
๏€ผ๏€‚
๏€‡๏€
90
WS TT F1 Y1
Isolator switch Black bulb sensor Fuse 3-way valve (optional)
Reparatur schalter Schwarze kugel fรผhler Sicherung 3-wege ventil (optional)
Lโ€™interrupteur de proximitรฉ Capteur globe noir Fusible 3-voies vanne (optional)
Werkschakelaar Zwarte bol voeler Zekering 3-wegklep (optioneel)
Wyล‚acznik serwisowy Czujnik Czarna kula Bezpiecznik Zawรณr 3-drogowy (Opcja)
Switch pentru izolare Senzor glob Fitil Supapฤƒ cutrei cฤƒi (Optional)
[7]
[8]
EN
DE
FR
NL
PL
RO
๏€ ๏€‚ ๏€ƒ ๏€„ ๏€… ๏€† ๏€‡ ๏€ˆ ๏€‰ ๏€Š ๏€‚๏€ ๏€‚๏€‚ ๏€‚๏€ƒ ๏€‚๏€„ ๏€‚๏€… ๏€‚๏€† ๏€‚๏€‡ ๏€‚๏€ˆ ๏€‚๏€‰ ๏€‚๏€Š
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€”๏€•๏€๏€๏€๏€–๏€—
๏€˜๏€๏€—๏€™
๏€˜๏€๏€–๏€™
๏€ฒ๏€”๏๏€ผ๏€๏€ฃ๏€“
๏€Ÿ๏€™๏€ ๏€™
๏€Ž๏€ก๏€œ
๏€œ๏€š๏€—๏€ข๏€’
๏€ฃ๏€•๏€‘๏€’
๏€‚๏€ค๏€†๏€ค๏€ƒ๏€๏€‚๏€‰
๏€ฅ๏€–๏€๏€š๏€ฆ๏€—๏€ง๏€ฆ๏€š๏€๏€ค
๏€๏€ข๏€’๏€’๏€๏€‘
๏€˜๏€‘๏€ข๏€ง๏€ง๏€
๏€๏€‘๏€—๏€™๏€๏€‘
๏€Ž๏€๏€๏€‘๏€’๏€•๏€จ๏€—๏€š๏€—๏€จ ๏€Ž๏€ฉ๏€ง๏€
๏€ž๏€๏€‘๏€จ๏€Œ๏€•๏€
๏€Ž๏€ช๏€ค๏€๏€‡๏€ƒ๏€Š๏€‚๏€๏€‰
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’
๏€‚๏€™๏€
๏€‚๏€ƒ
๏€ƒ๏€‚
๏€ƒ๏€
๏€Œ๏€“๏€๏€“๏€๏€“๏€•๏€“๏€ก๏€“๏€š๏€“๏€—๏€“๏€Œ๏€“๏€ก๏€“๏€๏€“๏€ช๏€“๏€š๏€“๏€ฆ๏€“๏€ฆ๏€“๏€๏€“๏€๏€“๏€๏€“๏€๏€“๏€Œ๏€“๏€ซ๏€“๏€ข๏€“๏€๏€“๏€ฌ
๏€ญ
๏€ฎ๏€ ๏€ญ ๏€ฏ ๏€ค ๏€‚๏€‚ ๏€‚๏€ƒ ๏€ฐ๏€ฃ
๏€ƒ๏€ƒ๏€ƒ๏€‚
๏€ƒ๏€…๏€ƒ๏€„
๏€ƒ๏€‡๏€ƒ๏€†
๏€‚๏€…๏€‚๏€„
๏€‚๏€ต๏€ƒ๏€„๏€๏€ž๏€“๏€ฏ๏€“๏€‹๏€ฒ๏€ณ๏€†๏€๏€ช๏€ซ
๏€‚๏€†๏€ƒ๏€„๏€…
๏€Ž๏€ช๏€ค๏€๏€‡๏€ƒ๏€Š๏€‚๏€๏€‰ ๏€ณ๏€ณ ๏€‚๏€™๏€๏€ƒ๏€ ๏€ณ๏€ณ
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€–๏€•๏€๏€๏€๏€–๏€—๏€“๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€‚๏€๏€‰ ๏€ฒ๏€”๏๏€ผ๏€๏€ฃ๏€“๏€ ๏€…๏€ƒ๏€ณ๏€ ๏€‰๏€ƒ๏€ณ๏€ ๏€‚๏€…๏€ƒ
๏€›๏€•๏€น๏€ฎ๏€ข๏€จ๏€Ž๏€”๏€‹๏€ณ๏€บ๏€‹
๏€‚๏€ƒ
๏€ฃ๏€Ž๏€”๏€“๏€…๏€ถ๏€ˆ๏€ท
๏€‚
๏€ƒ
๏€ญ๏€ธ
๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€๏€‰๏€‡
๏€Ž๏€Ž
๏€Ž๏€Ž ๏€ค ๏€ฒ๏€ธ๏€—๏€๏€‘๏€๏€๏€“๏€‘๏€ข๏€Œ๏€’๏€—๏€๏€ก๏€•๏€๏€ฆ๏€๏€‘
๏€ ๏€๏€‘๏€ป๏€จ๏€–๏€๏€š๏€ป๏€๏€ฆ๏€š๏€š๏€‘๏€ ๏€ฅ ๏€ค
๏€ฑ๏€๏€ป๏€๏€‘๏€Œ๏€๏€ฌ๏€ผ๏€‚ ๏€ค
๏€ฐ๏€‚๏€ฃ๏€‹๏€ฒ
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€”๏€•๏€๏€๏€๏€–๏€—๏€“๏€“๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€‚๏€๏€‰
๏€ฒ๏€”๏๏€ผ๏€๏€ฃ๏€“๏€ ๏€…๏€ƒ๏€ณ๏€ ๏€‰๏€ƒ๏€ณ๏€ ๏€‚๏€…๏€ƒ
๏€‚
๏€ƒ
๏€ ๏€ฅ
๏€„
๏€…
๏€ผ๏€‚
๏€‡๏€
๏€ ๏€‚ ๏€ƒ ๏€„ ๏€… ๏€† ๏€‡ ๏€ˆ ๏€‰ ๏€Š ๏€‚๏€ ๏€‚๏€‚ ๏€‚๏€ƒ ๏€‚๏€„ ๏€‚๏€… ๏€‚๏€† ๏€‚๏€‡ ๏€‚๏€ˆ ๏€‚๏€‰ ๏€‚๏€Š
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€”๏€•๏€๏€๏€๏€–๏€—
๏€˜๏€๏€—๏€™
๏€˜๏€๏€–๏€™
๏€ฒ๏€”๏๏€ผ๏€๏€ฃ๏€“๏€พ๏€๏€–๏€ค๏‚๏€š๏€๏€ฟ
๏€Ÿ๏€™๏€ ๏€™
๏€Ž๏€ก๏€œ
๏€œ๏€š๏€—๏€ข๏€’
๏€ฃ๏€•๏€‘๏€’
๏€‚๏€ค๏€†๏€ค๏€ƒ๏€๏€‚๏€‰
๏€ฅ๏€–๏€๏€š๏€ฆ๏€—๏€ง๏€ฆ๏€š๏€๏€ค
๏€๏€ข๏€’๏€’๏€๏€‘
๏€˜๏€‘๏€ข๏€ง๏€ง๏€
๏€๏€‘๏€—๏€™๏€๏€‘
๏€Ž๏€๏€๏€‘๏€’๏€•๏€จ๏€—๏€š๏€—๏€จ ๏€Ž๏€ฉ๏€ง๏€
๏€ž๏€๏€‘๏€จ๏€Œ๏€•๏€
๏€Ž๏€ช๏€ค๏€๏€‡๏€ƒ๏€Š๏€‚๏€๏€‰
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’
๏€‚๏€™๏€
๏€ƒ๏€
๏€„๏€
๏€ƒ๏€‚
๏€Œ๏€“๏€๏€“๏€๏€“๏€•๏€“๏€ก๏€“๏€š๏€“๏€—๏€“๏€Œ๏€“๏€ก๏€“๏€๏€“๏€ช๏€“๏€š๏€“๏€ฆ๏€“๏€ฆ๏€“๏€๏€“๏€๏€“๏€๏€“๏€๏€“๏€Œ๏€“๏€ซ๏€“๏€ข๏€“๏€๏€“๏€ฌ
๏€ญ
๏€ฎ๏€ ๏€ญ ๏€ฏ ๏€ค ๏€‚๏€‚ ๏€‚๏€ƒ ๏€ฐ๏€ฃ
๏€ƒ๏€ƒ๏€ƒ๏€‚
๏€ƒ๏€…๏€ƒ๏€„
๏€ƒ๏€‡๏€ƒ๏€†
๏€‚๏€…๏€‚๏€„
๏€‚๏€ต๏€ƒ๏€„๏€๏€ž๏€“๏€ฏ๏€“๏€‹๏€ฒ๏€ณ๏€†๏€๏€ช๏€ซ
๏€‚๏€†๏€ƒ๏€„๏€…
๏€ฐ๏€‚ ๏€ฃ ๏€‹๏€ฒ
๏€Ž๏€ช๏€ค๏€๏€‡๏€ƒ๏€Š๏€‚๏€๏€‰ ๏€ณ๏€ณ ๏€‚๏€™๏€๏€ƒ๏€‚ ๏€ณ๏€ณ
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€–๏€•๏€๏€๏€๏€–๏€—๏€“๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€‚๏€๏€‰ ๏€ฒ๏€”๏๏€ผ๏€๏€ฃ๏€“๏€ ๏€…๏€ƒ๏€ณ๏€ ๏€‰๏€ƒ๏€ณ๏€ ๏€‚๏€…๏€ƒ๏€“๏€พ๏€ฒ๏€”๏€ค๏€ผ๏€๏€ฃ๏€ฟ
๏€›๏€•๏€น๏€ฎ๏€ข๏€จ๏€Ž๏€”๏€‹๏€ณ๏€บ๏€‹
๏€‚๏€ƒ
๏€ฃ๏€Ž๏€”๏€“๏€…๏€ถ๏€ˆ๏€ท
๏€‚
๏€ƒ
๏€ญ๏€ธ
๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€๏€‰๏€‡
๏€Ž๏€Ž
๏€Ž๏€Ž ๏€ค ๏€ฒ๏€ธ๏€—๏€๏€‘๏€๏€๏€“๏€‘๏€ข๏€Œ๏€’๏€—๏€๏€ก๏€•๏€๏€ฆ๏€๏€‘
๏€ ๏€๏€‘๏€ป๏€จ๏€–๏€๏€š๏€ป๏€๏€ฆ๏€š๏€š๏€‘๏€ ๏€ฅ ๏€ค
๏€ฑ๏€๏€ป๏€๏€‘๏€Œ๏€๏€ฌ๏€ผ๏€‚ ๏€ค
๏€„๏€ค๏€ฝ๏€๏€ฌ๏€ป๏€ฆ๏€๏€ง๏€“๏€พ๏€•๏€ง๏€—๏€Œ๏€•๏€๏€๏€๏€ฆ๏€ฟ๏€“๏€๏€‚ ๏€ค
๏€ฐ๏€‚๏€ฃ๏€‹๏€ฒ
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€”๏€•๏€๏€๏€๏€–๏€—๏€“๏€“๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€‚๏€๏€‰
๏€ฒ๏€”๏๏€ผ๏€๏€ฃ๏€“๏€ ๏€…๏€ƒ๏€ณ๏€ ๏€‰๏€ƒ๏€ณ๏€ ๏€‚๏€…๏€ƒ๏€“๏€พ๏€ฒ๏€”๏€ค๏€ผ๏€๏€ฃ๏€ฟ
๏€‚
๏€ƒ
๏€ ๏€ฅ
๏€„
๏€…
๏€›๏€‚๏€ฒ๏€‚
๏€ผ๏€‚
๏€‡๏€
91
WS TT F1 Y1
Isolator switch Black bulb sensor Fuse 3-way valve (optional)
Reparatur schalter Schwarze kugel fรผhler Sicherung 3-wege ventil (optional)
Lโ€™interrupteur de proximitรฉ Capteur globe noir Fusible 3-voies vanne (optional)
Werkschakelaar Zwarte bol voeler Zekering 3-wegklep (optioneel)
Wyล‚acznik serwisowy Czujnik Czarna kula Bezpiecznik Zawรณr 3-drogowy (Opcja)
Switch pentru izolare Senzor glob Fitil Supapฤƒ cutrei cฤƒi (Optional)
WS TT F1 E1,E2
Isolator switch Black bulb sensor Fuse Connection box MDV
Reparatur schalter Schwarze kugel fรผhler Sicherung Verbindungsbox MDV
Lโ€™interrupteur de proximitรฉ Capteur globe noir Fusible Boรฎte de connexion MDV
Werkschakelaar Zwarte bol voeler Zekering Aansluitbox MDV
Wyล‚acznik serwisowy Czujnik Czarna kula Bezpiecznik Skrzynka przyล‚ฤ…czeniowa MDV
Switch pentru izolare Senzor glob Fitil Caseta de conectare MDV
[9]
EN
DE
FR
NL
PL
RO
๏€ ๏€‚ ๏€ƒ ๏€„ ๏€… ๏€† ๏€‡ ๏€ˆ ๏€‰ ๏€Š ๏€‚๏€ ๏€‚๏€‚ ๏€‚๏€ƒ ๏€‚๏€„ ๏€‚๏€… ๏€‚๏€† ๏€‚๏€‡ ๏€‚๏€ˆ ๏€‚๏€‰ ๏€‚๏€Š
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€”๏€•๏€๏€๏€๏€–๏€—
๏€˜๏€๏€—๏€™
๏€˜๏€๏€–๏€™
๏€›๏€œ๏€ž๏€“๏€พ๏€๏€–๏€ค๏‚๏€š๏€๏€ฟ
๏€Ÿ๏€™๏€ ๏€™
๏€Ž๏€ก๏€œ
๏€œ๏€š๏€—๏€ข๏€’
๏€ฃ๏€•๏€‘๏€’
๏€‚๏€ค๏€†๏€ค๏€ƒ๏€๏€‚๏€‰
๏€ฅ๏€–๏€๏€š๏€ฆ๏€—๏€ง๏€ฆ๏€š๏€๏€ค
๏€๏€ข๏€’๏€’๏€๏€‘
๏€˜๏€‘๏€ข๏€ง๏€ง๏€
๏€๏€‘๏€—๏€™๏€๏€‘
๏€Ž๏€๏€๏€‘๏€’๏€•๏€จ๏€—๏€š๏€—๏€จ ๏€Ž๏€ฉ๏€ง๏€
๏€ž๏€๏€‘๏€จ๏€Œ๏€•๏€
๏€Ž๏€ช๏€ค๏€๏€‡๏€ƒ๏€Š๏€‚๏€๏€‰
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’
๏€‚๏€™๏€
๏€…๏€‚
๏€†๏€‚
๏€†๏€
๏€Œ๏€“๏€๏€“๏€๏€“๏€•๏€“๏€ก๏€“๏€š๏€“๏€—๏€“๏€Œ๏€“๏€ก๏€“๏€๏€“๏€ช๏€“๏€š๏€“๏€ฆ๏€“๏€ฆ๏€“๏€๏€“๏€๏€“๏€๏€“๏€๏€“๏€Œ๏€“๏€ซ๏€“๏€ข๏€“๏€๏€“๏€ฌ
๏€ญ
๏€ฎ๏€ ๏€ญ ๏€ฏ ๏€ค ๏€‚๏€‚ ๏€‚๏€ƒ ๏€ฐ๏€ฃ
๏€ƒ๏€ƒ๏€ƒ๏€‚
๏€ƒ๏€…๏€ƒ๏€„
๏€ƒ๏€‡๏€ƒ๏€†
๏€‚๏€…๏€‚๏€„
๏€ฉ๏€๏€ณ๏€ฌ๏€‘
๏…๏€ฆ
๏€ฎ๏€ท
๏€ฝ๏€๏€“๏€‚
๏€ฝ๏€๏€“๏€ƒ
๏€ท
๏€‘๏€น
๏€ฉ๏€
๏…๏€ฆ
๏…๏€‘
๏€ฝ๏€
๏€‚๏€ต๏€ƒ๏€„๏€๏€ž๏€“๏€ฏ๏€“๏€‹๏€ฒ๏€ณ๏€†๏€๏€ช๏€ซ
๏€Ž๏€ช๏€ค๏€๏€‡๏€ƒ๏€Š๏€‚๏€๏€‰ ๏€ณ๏€ณ ๏€‚๏€™๏€๏€†๏€ ๏€ณ๏€ณ
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€–๏€•๏€๏€๏€๏€–๏€—๏€“๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€‚๏€๏€‰ ๏€›๏€œ๏€ž๏€“๏€พ๏€ฒ๏€”๏€ค๏€ผ๏€๏€ฃ๏€“๏€ƒ๏€„๏€๏€ž๏€ฟ
๏€›๏€•๏€น๏€ฎ๏€ข๏€จ๏€Ž๏€”๏€‹๏€ณ๏€บ๏€‹
๏€‚๏€ƒ
๏€ฃ๏€Ž๏€”๏€“๏€…๏€ถ๏€ˆ๏€ท
๏€‚
๏€ƒ
๏€ญ๏€ธ
๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€๏€‰๏€‡
๏€Ž๏€Ž
๏€Ž๏€Ž ๏€ค ๏€ฒ๏€ธ๏€—๏€๏€‘๏€๏€๏€“๏€‘๏€ข๏€Œ๏€’๏€—๏€๏€ก๏€•๏€๏€ฆ๏€๏€‘
๏€ ๏€๏€‘๏€ป๏€จ๏€–๏€๏€š๏€ป๏€๏€ฆ๏€š๏€š๏€‘๏€ ๏€ฅ ๏€ค
๏€ฑ๏€๏€ป๏€๏€‘๏€Œ๏€๏€ฌ๏€ผ๏€‚ ๏€ค
๏€๏€š๏€๏€จ๏€ฆ๏€ข๏€Œ๏€—๏…๏€•๏€ธ๏€“๏€›๏€œ๏€ž๏€ฒ๏€‚๏€ถ๏€ฒ๏€ƒ ๏€ค
๏€ฐ๏€‚๏€ฃ๏€‹๏€ฒ
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€”๏€•๏€๏€๏€๏€–๏€—๏€“๏€“๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€‚๏€๏€‰
๏€‚
๏€ƒ
๏€ ๏€ฅ
๏€ฒ๏€‚๏€ฒ๏€ƒ
๏€„
๏€…
๏€›๏€œ๏€ž๏€“๏€ฒ๏€”
๏€ผ๏€‚
๏€‡๏€
92
[10]
๏€ ๏€‚ ๏€ƒ ๏€„ ๏€… ๏€† ๏€‡ ๏€ˆ ๏€‰ ๏€Š ๏€‚๏€ ๏€‚๏€‚ ๏€‚๏€ƒ ๏€‚๏€„ ๏€‚๏€… ๏€‚๏€† ๏€‚๏€‡ ๏€‚๏€ˆ ๏€‚๏€‰ ๏€‚๏€Š
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€”๏€•๏€๏€๏€๏€–๏€—
๏€˜๏€๏€—๏€™
๏€˜๏€๏€–๏€™
๏€›๏€œ๏€ž๏€“๏€พ๏€๏€–๏€ค๏‚๏€š๏€๏€ฟ
๏€Ÿ๏€™๏€ ๏€™
๏€Ž๏€ก๏€œ
๏€œ๏€š๏€—๏€ข๏€’
๏€ฃ๏€•๏€‘๏€’
๏€‚๏€ค๏€†๏€ค๏€ƒ๏€๏€‚๏€‰
๏€ฅ๏€–๏€๏€š๏€ฆ๏€—๏€ง๏€ฆ๏€š๏€๏€ค
๏€๏€ข๏€’๏€’๏€๏€‘
๏€˜๏€‘๏€ข๏€ง๏€ง๏€
๏€๏€‘๏€—๏€™๏€๏€‘
๏€Ž๏€๏€๏€‘๏€’๏€•๏€จ๏€—๏€š๏€—๏€จ ๏€Ž๏€ฉ๏€ง๏€
๏€ž๏€๏€‘๏€จ๏€Œ๏€•๏€
๏€Ž๏€ช๏€ค๏€๏€‡๏€ƒ๏€Š๏€‚๏€๏€‰
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’
๏€‚๏€™๏€
๏€†๏€
๏€‚๏€๏€
๏€†๏€‚
๏€Œ๏€“๏€๏€“๏€๏€“๏€•๏€“๏€ก๏€“๏€š๏€“๏€—๏€“๏€Œ๏€“๏€ก๏€“๏€๏€“๏€ช๏€“๏€š๏€“๏€ฆ๏€“๏€ฆ๏€“๏€๏€“๏€๏€“๏€๏€“๏€๏€“๏€Œ๏€“๏€ซ๏€“๏€ข๏€“๏€๏€“๏€ฌ
๏€ญ
๏€ฎ๏€ ๏€ญ ๏€ฏ ๏€ค ๏€‚๏€‚ ๏€‚๏€ƒ ๏€ฐ๏€ฃ
๏€ƒ๏€ƒ๏€ƒ๏€‚
๏€ƒ๏€…๏€ƒ๏€„
๏€ƒ๏€‡๏€ƒ๏€†
๏€‚๏€…๏€‚๏€„
๏€ฐ๏€‚ ๏€ฐ๏€ƒ ๏€˜๏€ฃ๏€œ๏€ฐ๏€„
๏€ท๏€ฐ๏€“๏€‚ ๏€ท๏€ฐ๏€“๏€ƒ
๏€„๏€ต๏€“๏€…๏€๏€๏€ž๏€“๏€ฏ๏€‹๏€ฒ๏€“๏€ณ๏€“๏€†๏€๏€ช๏€ซ
๏€๏€Œ๏€๏€‚
๏€ด
๏€‚๏€ต๏€ƒ๏€„๏€๏€ž๏€“๏€ฏ๏€“๏€‹๏€ฒ๏€ณ๏€†๏€๏€ช๏€ซ
๏€Ž๏€ช๏€ค๏€๏€‡๏€ƒ๏€Š๏€‚๏€๏€‰ ๏€ณ๏€ณ ๏€‚๏€™๏€๏€†๏€‚ ๏€ณ๏€ณ
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€–๏€•๏€๏€๏€๏€–๏€—๏€“๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€‚๏€๏€‰ ๏€›๏€œ๏€ž๏€“๏€พ๏€ฒ๏€”๏€ค๏€ผ๏€๏€ฃ๏€“๏€…๏€๏€๏€ž๏€ฟ
๏€›๏€•๏€น๏€ฎ๏€ข๏€จ๏€Ž๏€”๏€‹๏€ณ๏€บ๏€‹
๏€‚๏€ƒ
๏€ฃ๏€Ž๏€”๏€“๏€…๏€ถ๏€ˆ๏€ท
๏€‚
๏€ƒ
๏€ญ๏€ธ
๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€๏€‰๏€‡
๏€Ž๏€Ž
๏€Ž๏€Ž ๏€ค ๏€ฒ๏€ธ๏€—๏€๏€‘๏€๏€๏€“๏€‘๏€ข๏€Œ๏€’๏€—๏€๏€ก๏€•๏€๏€ฆ๏€๏€‘
๏€ ๏€๏€‘๏€ป๏€จ๏€–๏€๏€š๏€ป๏€๏€ฆ๏€š๏€š๏€‘๏€ ๏€ฅ ๏€ค
๏€ฑ๏€๏€ป๏€๏€‘๏€Œ๏€๏€ฌ๏€ผ๏€‚๏€ถ๏€ผ๏€ƒ ๏€ค
๏€„๏€ค๏€ฝ๏€๏€ฌ๏€ป๏€ฆ๏€๏€ง๏€“๏€พ๏€•๏€ง๏€—๏€Œ๏€•๏€๏€๏€๏€ฆ๏€ฟ๏€“๏€๏€‚ ๏€ค
๏€ฐ๏€‚๏€ฃ๏€‹๏€ฒ
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€”๏€•๏€๏€๏€๏€–๏€—๏€“๏€“๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€‚๏€๏€‰
๏€ฐ๏€ƒ๏€ฐ๏€‚ ๏€‹๏€ฒ๏€ฐ๏€„
๏€‚
๏€ƒ
๏€ ๏€ฅ
๏€„
๏€…
๏€„
๏€…
๏€›๏€œ๏€ž๏€“๏€ฒ๏€”
๏€ผ๏€‚
๏€‡๏€
๏€ผ๏€ƒ
WS TT F1 Y1
Isolator switch Black bulb sensor Fuse 3-way valve (optional)
Reparatur schalter Schwarze kugel fรผhler Sicherung 3-wege ventil (optional)
Lโ€™interrupteur de proximitรฉ Capteur globe noir Fusible 3-voies vanne (optional)
Werkschakelaar Zwarte bol voeler Zekering 3-wegklep (optioneel)
Wyล‚acznik serwisowy Czujnik Czarna kula Bezpiecznik Zawรณr 3-drogowy (Opcja)
Switch pentru izolare Senzor glob Fitil Supapฤƒ cutrei cฤƒi (Optional)
EN
DE
FR
NL
PL
RO
93
TT
Black bulb sensor
Schwarze kugel fรผhler
Capteur globe noir
Zwarte bol voeler
Czujnik Czarna kula
Senzor glob
[11]
EN
DE
FR
NL
PL
RO
WS TT F1 Y1
Isolator switch Black bulb sensor Fuse 3-way valve (optional)
Reparatur schalter Schwarze kugel fรผhler Sicherung 3-wege ventil (optional)
Lโ€™interrupteur de proximitรฉ Capteur globe noir Fusible 3-voies vanne (optional)
Werkschakelaar Zwarte bol voeler Zekering 3-wegklep (optioneel)
Wyล‚acznik serwisowy Czujnik Czarna kula Bezpiecznik Zawรณr 3-drogowy (Opcja)
Switch pentru izolare Senzor glob Fitil Supapฤƒ cutrei cฤƒi (Optional)
๏€ ๏€‚ ๏€ƒ ๏€„ ๏€… ๏€† ๏€‡ ๏€ˆ ๏€‰ ๏€Š ๏€‚๏€ ๏€‚๏€‚ ๏€‚๏€ƒ ๏€‚๏€„ ๏€‚๏€… ๏€‚๏€† ๏€‚๏€‡ ๏€‚๏€ˆ ๏€‚๏€‰ ๏€‚๏€Š
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€”๏€•๏€๏€๏€๏€–๏€—
๏€˜๏€๏€—๏€™
๏€˜๏€๏€–๏€™
๏€…๏€š๏€“๏€Ž๏€Ž
๏€›๏€™๏€œ๏€™
๏€Ž๏€๏€ž
๏€ž๏€Ÿ๏€—๏€ ๏€’
๏€ก๏€•๏€‘๏€’
๏€‚๏€ข๏€†๏€ข๏€ƒ๏€๏€‚๏€‰
๏€ฃ๏€–๏€๏€Ÿ๏€ค๏€—๏€ฅ๏€ค๏€Ÿ๏€๏€ข
๏€๏€ ๏€’๏€’๏€๏€‘
๏€˜๏€‘๏€ ๏€ฅ๏€ฅ๏€
๏€ฆ๏€‘๏€—๏€™๏€๏€‘
๏€Ž๏€๏€๏€‘๏€’๏€•๏€ง๏€—๏€Ÿ๏€—๏€ง ๏€Ž๏€จ๏€ฅ๏€
๏€ฉ๏€๏€‘๏€ง๏€Œ๏€•๏€
๏€Ž๏€ช๏€ข๏€๏€‡๏€ƒ๏€Š๏€‚๏€๏€‰
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’
๏€‚๏€™๏€
๏€†๏€‚
๏€‚๏€๏€
๏€Š๏€
๏€Œ๏€“๏€๏€“๏€๏€“๏€•๏€“๏€๏€“๏€Ÿ๏€“๏€—๏€“๏€Œ๏€“๏€๏€“๏€๏€“๏€ช๏€“๏€Ÿ๏€“๏€ค๏€“๏€ค๏€“๏€๏€“๏€๏€“๏€๏€“๏€๏€“๏€Œ๏€“๏€ซ๏€“๏€ ๏€“๏€๏€“๏€ฌ
๏€ญ
๏€ฎ๏€ฆ ๏€ญ ๏€ฏ ๏€ข ๏€‚๏€‚ ๏€‚๏€ƒ ๏€ฐ๏€ก
๏€ƒ๏€ƒ๏€ƒ๏€‚
๏€ƒ๏€…๏€ƒ๏€„
๏€ƒ๏€‡๏€ƒ๏€†
๏€‚๏€…๏€‚๏€„
๏€Ž๏€ช๏€ข๏€๏€‡๏€ƒ๏€Š๏€‚๏€๏€‰ ๏€ฑ๏€ฑ ๏€‚๏€™๏€๏€Š๏€ ๏€ฑ๏€ฑ
๏€ฒ๏€•๏€ณ๏€ฎ๏€ ๏€ง
๏€Ž๏€”๏€‹๏€ฑ๏€ด๏€‹
๏€‚๏€ƒ
๏€ก๏€Ž๏€”๏€“๏€…๏€ต๏€ˆ๏€ถ
๏€‚
๏€ƒ
๏€ญ๏€š
๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€๏€‰๏€‡
๏€Ž๏€Ž
๏€‚๏€ƒ
๏€ก๏€Ž๏€”๏€“๏€…๏€ต๏€ˆ๏€ถ
๏€‚
๏€ƒ
๏€ญ๏€š
๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€๏€‰๏€‡
๏€Ž๏€Ž
๏€‚๏€ƒ
๏€ก๏€Ž๏€”๏€“๏€…๏€ต๏€ˆ๏€ถ
๏€‚
๏€ƒ
๏€ญ๏€š
๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€๏€‰๏€‡
๏€Ž๏€Ž
๏€‚๏€ƒ
๏€ก๏€Ž๏€”๏€“๏€…๏€ต๏€ˆ๏€ถ
๏€‚
๏€ƒ
๏€ญ๏€š
๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€๏€‰๏€‡
๏€Ž๏€Ž
๏€Ž๏€Ž ๏€ข ๏€ท๏€š๏€—๏€๏€‘๏€๏€๏€“๏€‘๏€ ๏€Œ๏€’๏€—๏€๏€๏€•๏€๏€ค๏€๏€‘
๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€”๏€•๏€๏€๏€๏€–๏€—๏€“๏€“๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€‚๏€๏€‰
94
[12]
Modbus RTU
Baudrate 19200
Data bits 8
Parity Even
Stop bits 1
Slave ID 1-247 (default: 1)
Minimum read-request interval 100 msec or longer
Response timeout 500 msec
Modbus TCP
Port 502
Slave ID 255
Minimum read-request interval 50 msec or longer
Response timeout 500 msec
Register
Address
R/W Description Raw Value Range/Settings Notes
HOLING REGISTERS
0 R Vendor ID
1 R Product ID
2 R Firmware version Minor/Major 0..65535 MSB: Major
LSB: Minor
3 R Firmware version Branch/Revision 0..65535 MSB: Branch
LSB: Revision
4 R Serial number bytes 0..1 0..65535
5 R Serial number bytes 2..3 0..65535
6 R Serial number bytes 4..5 0..65535
7 R/W Language 0..6 0 - NL
1 - EN
2 - DE
3 - FR
4 - PL
5 - RO
6 - LT
16 R Gas Burner fault 0-1 0 - normal
1 - fault
17 R/W Fault reset 0 - 1
0 - no reset active
1 - perform reset ( write 1 to reset, auto-cleared when reset
sequence has completed +- 12 seconds)
18 R/W Overtime Timer 0/60/120/180
- 60/120/180 minutes
- 0 to deactivate the overtime
Automatically counts down to zero
32 R/W Heat Request 0 - 1 0 - No heat request
1 - Heat request
33 R/W High/low mode active 0- 1 0 - Low mode active
1 - High mode active
34 R/W Temperature Day 0..39 0..39ยฐC
35 R/W Temperature Night 0..39 0..39ยฐC
36 R/W Temperature calibration -35..35 -3.5 .. +3.5ยฐC
37 R/W High/low Switch 0..3 1 .. 3K, 0 = Manual Mode
95
Register
Address
R/W Description Raw Value Range/Settings Notes
HOLING REGISTERS
0 R Vendor ID
1 R Product ID
2 R Firmware version Minor/Major 0..65535 MSB: Major
LSB: Minor
3 R Firmware version Branch/Revision 0..65535 MSB: Branch
LSB: Revision
4 R Serial number bytes 0..1 0..65535
5 R Serial number bytes 2..3 0..65535
6 R Serial number bytes 4..5 0..65535
7 R/W Language 0..6 0 - NL
1 - EN
2 - DE
3 - FR
4 - PL
5 - RO
6 - LT
16 R Gas Burner fault 0-1 0 - normal
1 - fault
17 R/W Fault reset 0 - 1
0 - no reset active
1 - perform reset ( write 1 to reset, auto-cleared when reset
sequence has completed +- 12 seconds)
18 R/W Overtime Timer 0/60/120/180
- 60/120/180 minutes
- 0 to deactivate the overtime
Automatically counts down to zero
32 R/W Heat Request 0 - 1 0 - No heat request
1 - Heat request
33 R/W High/low mode active 0- 1 0 - Low mode active
1 - High mode active
34 R/W Temperature Day 0..39 0..39ยฐC
35 R/W Temperature Night 0..39 0..39ยฐC
36 R/W Temperature calibration -35..35 -3.5 .. +3.5ยฐC
37 R/W High/low Switch 0..3 1 .. 3K, 0 = Manual Mode
[13]
96
38 R/W Modulating Control 0 - 1 0 = Inactive, 1 = Active
39 R/W Minimal Activation Time 5/10/15/20 5, 10, 15 or 20 Min
44 R Switching differential L1 10 1K
45 R Switching differential L3 5 0.5K
48 R/W Vacation planning start day 1..31 1..31
The dates are automatically validated when a write
request is completed
49 R/W Vacation planning start month 1..12 1..12 When the date is invalid, the date will not be updated.
50 R/W Vacation planning start year 1900.. 1900..
To write the vacation planning it's adviced to use use
function
51 R/W Vacation planning end day 1..31 1..31
0x10 ( Write Multiple Registers). With a Write Single
Register request, the old
52 R/W Vacation planning end month 1..12 1..12 data and new data can form a invalid date.
53 R/W Vacation planning end year 1900.. 1900..
54 R/W Vacation planning active 0 - 1 0 = inactive, 1 = active
Current Date/Time
55 R/W Current time Seconds 0..59 0..59 seconds
The date/time is automatically validated when a write
request is completed.
56 R/W Current time Minutes 0..59 0..59 minutes
When the date/time is invalid the date/time will not be
updated
57 R/W Current time Hours 0..23 0..23 Hours
To write the vacation planning it's adviced to use use
function
58 R/W Current date Day 0..31 0..31 day of month
0x10 ( Write Multiple Registers). With a Write Single
Register request, the old
59 R/W Current date Month 1..12 1..12 month of year data and new data can form a invalid date.
60 R/W Current date Year 0..9999 Current year between 0..9999
Sunday
64 R/W Program 1 Start 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
65 R/W Program 1 End 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
66 R/W Program 2 Start 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
67 R/W Program 2 End 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
68 R/W Program 3 Start 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
69 R/W Program 3 End 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
Monday
80 R/W Program 1 Start 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
81 R/W Program 1 End 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
82 R/W Program 2 Start 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
83 R/W Program 2 End 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
84 R/W Program 3 Start 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
85 R/W Program 3 End 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
Tuesday
96 R/W Program 1 Start 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
97 R/W Program 1 End 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
98 R/W Program 2 Start 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
99 R/W Program 2 End 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
100 R/W Program 3 Start 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
101 R/W Program 3 End 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
Wednesday
112 R/W Program 1 Start 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
113 R/W Program 1 End 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
114 R/W Program 2 Start 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
115 R/W Program 2 End 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
116 R/W Program 3 Start 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
117 R/W Program 3 End 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
Thursday
128 R/W Program 1 Start 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
129 R/W Program 1 End 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
130 R/W Program 2 Start 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
131 R/W Program 2 End 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
132 R/W Program 3 Start 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
133 R/W Program 3 End 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
Friday
144 R/W Program 1 Start 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
97
38 R/W Modulating Control 0 - 1 0 = Inactive, 1 = Active
39 R/W Minimal Activation Time 5/10/15/20 5, 10, 15 or 20 Min
44 R Switching differential L1 10 1K
45 R Switching differential L3 5 0.5K
48 R/W Vacation planning start day 1..31 1..31
The dates are automatically validated when a write
request is completed
49 R/W Vacation planning start month 1..12 1..12 When the date is invalid, the date will not be updated.
50 R/W Vacation planning start year 1900.. 1900..
To write the vacation planning it's adviced to use use
function
51 R/W Vacation planning end day 1..31 1..31
0x10 ( Write Multiple Registers). With a Write Single
Register request, the old
52 R/W Vacation planning end month 1..12 1..12 data and new data can form a invalid date.
53 R/W Vacation planning end year 1900.. 1900..
54 R/W Vacation planning active 0 - 1 0 = inactive, 1 = active
Current Date/Time
55 R/W Current time Seconds 0..59 0..59 seconds
The date/time is automatically validated when a write
request is completed.
56 R/W Current time Minutes 0..59 0..59 minutes
When the date/time is invalid the date/time will not be
updated
57 R/W Current time Hours 0..23 0..23 Hours
To write the vacation planning it's adviced to use use
function
58 R/W Current date Day 0..31 0..31 day of month
0x10 ( Write Multiple Registers). With a Write Single
Register request, the old
59 R/W Current date Month 1..12 1..12 month of year data and new data can form a invalid date.
60 R/W Current date Year 0..9999 Current year between 0..9999
Sunday
64 R/W Program 1 Start 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
65 R/W Program 1 End 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
66 R/W Program 2 Start 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
67 R/W Program 2 End 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
68 R/W Program 3 Start 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
69 R/W Program 3 End 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
Monday
80 R/W Program 1 Start 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
81 R/W Program 1 End 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
82 R/W Program 2 Start 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
83 R/W Program 2 End 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
84 R/W Program 3 Start 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
85 R/W Program 3 End 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
Tuesday
96 R/W Program 1 Start 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
97 R/W Program 1 End 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
98 R/W Program 2 Start 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
99 R/W Program 2 End 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
100 R/W Program 3 Start 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
101 R/W Program 3 End 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
Wednesday
112 R/W Program 1 Start 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
113 R/W Program 1 End 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
114 R/W Program 2 Start 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
115 R/W Program 2 End 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
116 R/W Program 3 Start 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
117 R/W Program 3 End 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
Thursday
128 R/W Program 1 Start 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
129 R/W Program 1 End 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
130 R/W Program 2 Start 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
131 R/W Program 2 End 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
132 R/W Program 3 Start 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
133 R/W Program 3 End 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
Friday
144 R/W Program 1 Start 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
98
145 R/W Program 1 End 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
146 R/W Program 2 Start 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
147 R/W Program 2 End 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
148 R/W Program 3 Start 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
149 R/W Program 3 End 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
Saturday
160 R/W Program 1 Start 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
161 R/W Program 1 End 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
162 R/W Program 2 Start 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
163 R/W Program 2 End 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
164 R/W Program 3 Start 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
165 R/W Program 3 End 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
Input Register
0 Temperature -100..950 -10.0..95.0ยฐC
99
145 R/W Program 1 End 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
146 R/W Program 2 Start 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
147 R/W Program 2 End 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
148 R/W Program 3 Start 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
149 R/W Program 3 End 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
Saturday
160 R/W Program 1 Start 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
161 R/W Program 1 End 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
162 R/W Program 2 Start 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
163 R/W Program 2 End 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
164 R/W Program 3 Start 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
165 R/W Program 3 End 0..2359 Hours in multiples of 100 plus minutes (1230 means 12:30)
Input Register
0 Temperature -100..950 -10.0..95.0ยฐC
MARK BV
BENEDEN VERLAAT 87-89
VEENDAM (NEDERLAND)
POSTBUS 13, 9640 AA VEENDAM
TELEFOON +31(0)598 656600
FAX +31 (0)598 624584
www.mark.nl
MARK EIRE BV
COOLEA, MACROOM
CO. CORK
P12 W660 (IRELAND)
PHONE +353 (0)26 45334
FAX +353 (0)26 45383
www.markeire.com
MARK BELGIUM b.v.b.a.
ENERGIELAAN 12
2950 KAPELLEN
(BELGIร‹/BELGIQUE)
TELEFOON +32 (0)3 6669254
FAX +32 (0)3 6666578
www.markbelgium.be
MARK DEUTSCHLAND GmbH
MAX-PLANCK-STRASSE 16
46446 EMMERICH AM RHEIN
(DEUTSCHLAND)
TELEFON +49 (0)2822 97728-0
TELEFAX +49 (0)2822 97728-10
www.mark.de
MARK POLSKA Sp. z o.o
UL. JASNOGร“RSKA 27
42-202 CZฤ˜STOCHOWA ( PO L S K A)
PHONE +48 34 3683443
FAX +48 34 3683553
www.markpolska.pl
S.C. MARK ROMANIA S.R.L.
STR. KOS KAROLY NR. 1 A
540297 TARGU MURES
(ROMANIA)
TEL/FAX +40 (0)265-266.332
www.markromania.ro
CERTIFICATION Nยฐ: 17.07.011
AIRSTREAM
CERTIFICATION Nยฐ: 17.07.011
AIRSTREAM
CERTIFICATION Nยฐ: 17.07.011
AIRSTREAM
CERTIFICATION Nยฐ: 17.07.011
AIRSTREAM

Documenttranscriptie

Technical manual EN Technisches Handbuch DE Livret technique FR Technisch boek NL Instrukcja techniczna PL 0664047 MARK PinTherm CONNECT Manuel tehnic PinTherm Connect 06.29.108 MON 08:01 DAY 18ºC X:060 0 I RESET OK ESC 06 29 108 RO Read this document before installing the appliance Warning Incorrect installation, adjustment, alteration, repair or maintenance work may lead to material damage or injury. All work must be carried out by certified, qualified professionals. If the appliance is not positioned in accordance with the instructions, the warranty shall be rendered void. This appliance is not intended for use by children or persons with a physical, sensory or mental handicap, or who lack the required experience or expertise, unless they are supervised or have been instructed in the use of the appliance by somebody who is responsible for their safety. Children must be supervised to ensure that they do not play with the appliance. 2 1.0 Contents EN 2.0 General 2.1 All rights reserved 2.2 General warnings page page 4 4 3.0 Technical specifications 3.1 Technical specifications PinTherm Connect 3.2 Technical specifications external room sensor (optional) 3.3 Resistance chart room sensor (optional) 3.4 Default settings PinTherm Connect page page page page 4 5 5 5 4.0 Installation 4.1 General 4.2 Installation PinTherm Connect 4.3 Installation external room sensor page page page 6 6 6 5.0 Operating manual 5.1 Explanation of the push-buttons and LEDs 5.2 Explanation of the display 5.3 Initial operation of the PinTherm Connect 5.4 Activate user menu 5.5 Enter or change switching times 5.6 Change day/night temperature setting 5.7 Change time and date 5.8 Vacation settings 5.9 Change menu code 5.10 Change language 5.11 Calibration temperature 5.12 Heating/Cooling 5.13 Switching difference 5.14 Changing minimum control signal 5.15 Changing maximum control signal 5.16 Change control signal range 5.17 Modbus 5.18 Ethernet info 5.19 IP settings 5.20 Switch overtime timer on/off 5.21 Switch on chimney-sweep function 5.22 Restore factory settings PinTherm Connect page page page page page page page page page page page page page page page page page page page page page page 7 8 8 9 9 10 10 10 10 11 11 11 12 12 12 12 13 13 13 13 14 14 6.0 Disposing of the PinTherm Connect page 14 7.0 Modbus page 14 8.0 PinTherm Connect connections page 15 Annex I Annex II page page 87 94 Wiring diagrams Modbus 3 2.0 General 2.1 All rights reserved The manufacturer has a policy of continuous product improvement and reserves the right to make changes to the specifications without prior notice. The technical details are considered correct but do not form the basis for a contract or warranty. All orders are accepted subject to the standard terms and conditions of sale and delivery (which will be sent to you at your request). 2.2 General warnings Installation must comply with the relevant local and/or national regulations. You must therefore have the PinTherm Connect installed by a professionally qualified installer in accordance with all applicable national and international regulations. Faulty installation, adjustment, alteration, maintenance activity or repair shall render the warranty void. Always switch off the 230V power supply before connecting the terminals. The mains voltage on the PinTherm Connect must be able to be switched off in a double-pole manner by means of a permanent switch that is suitable for 250VAC / 10A and complies with the applicable safety regulations. Only devices that comply with EN-IEC 61010-1 may be operated with the PinTherm Connect. Clean the housing of the PinTherm Connect with a damp cloth. Do not apply solvents. There are no requirements regarding ventilation in the immediate vicinity of the controller. Warning - risk of electric shock. ! Warning - general warning, risk of danger. There can be voltage on the connection terminals where a ! is placed. 3.0 Technical specifications 3.1 Technical specifications PinTherm Connect • Type designation : PinTherm Connect • Item number : 06 29 108 • Power supply PinTherm Connect : 90 – 240 VAC / 47-63Hz • Own consumption : < 9W • Clock : 24 hour clock with automatic summer/winter time switching • Switching programs : 3 switching programs a day • Switching differential : 0,1 - 3K • Dimensions : 166 x 160 x 106mm (bxwxh) • Weight : 880 grammes • Protection class : IP-54 • Installation environment : Transport/storage: -20°C until +70°C. Operational: -10°C until +60°C Relative air humidity: 0-90% not condensating Installation maximal 2000 meter above sea level. • Over voltage category : 11 • Pollution level : 2 • Switch contact(s)* : Heating: 230Vac/16A (4A) Others: 230Vac/10A (2,5A) • Temperature setting : 0 until 39°C per 1°C adjustable • Overtime timer : adjustable 1, 2 or 3 hours (060, 120, 180) 4 • • • • • • Calibration Heating/cooling 0-10 VDC Sensor Languages Fuse : : : : : : adjustable from -3.5°C until +3.5°C Reversible contact for heating or cooling 0-10 VDC output for heating or cooling external room sensor (06 29 086) NL/EN/DE/FR/PL/RO/LT 6A EN * The relay contacts are functional switches, not safety switches. 3.2 Technical details external room sensor (optional) • Type designation : RSTF NTC4,7K • Item number : 06 29 086 • Resistance : NTC 4K7 • Dimensions : 79 x 81 x 26mm (lxwxh) • Weight : 46 grammes • Electrical connection : 0.75 -1.5mm² • Protection class : IP-30 3.3 Resistance chart room sensor (optional) -15°C -10°C -5°C 32.937kโ„ฆ 25.217kโ„ฆ 19.392kโ„ฆ 0°C 15.040kโ„ฆ 5°C 11.743kโ„ฆ 10°C 9.241kโ„ฆ 15°C 7.330kโ„ฆ 20°C 5.855kโ„ฆ 35°C 3.071kโ„ฆ 40°C 2.512kโ„ฆ 45°C 2.066kโ„ฆ 50°C 1.709kโ„ฆ 25°C 4.700kโ„ฆ 30°C 3.777kโ„ฆ 3.4 Default settings PinTherm Connect • Menu code : 1000 • Switching times : MA, DI, WO, DO, VR 07:30-17:30 hours ZA, ZO 00:00-00:00 hours • Room temperature : Day setting 18°C Night setting 08°C • Calibration temp. : +0.0 • Switching difference : 1K • Heating/cooling : Heating • 0-10V range : 1K • 0-10V min : 0V • 0-10V max : 10V • Modbus : Slave ID 001 • IP-setting : static 5 4.0 Installation 4.1 General After unpacking, check the PinTherm Connect and the external room sensor (if applicable) for damage. Check that the type/model and the rated voltage are correct. 4.2 Installation PinTherm Connect Determine a suitable place for installing the PinTherm Connect. Mount the PinTherm Connect on a solid surface that can carry a minimum of 4 kg. We recommend mounting the PinTherm Connect at a height of ±1.5m from the floor, at a well reachable place. For cable gland use only cable glands fitted with strain relief, with a minimum fire class of UL94V2. Check that the power supply has been switched off before connecting any wiring. If this is not the case, the power supply must be switched off before you continue. When switching off the power supply of the appliance to which connection is to be made, you should also refer to the technical documentation/operating instructions for the appliance in question. Connect the PinTherm Connect according to one of the supplied electrical diagrams which are in the back of this technical book. To select the correct connection diagram, you need to know on which type of device you will connect the PinTherm Connect. For a selection see also Annex I. When applying a 0-10VDC signal, see the table below for the correct cable diameter and associated length. Diameter 0.8mm2 1.0mm2 1.5mm2 Length 80 meter 100 meter 150 meter In this case, we advise the use of a shielded cable. 4.3 Installation external room sensor Place the external room sensor draft-free, in view of the appliance at a height of approx. 1.5m from the floor. And connect the sensor to the appropriate terminals in the PinTherm Connect. Refer to the chart below for the correct wire diameter and length. Diameter 0.8mm2 1.0mm2 1.5mm2 6 Length 80 meter 100 meter 150 meter In this case, we advise the use of a shielded cable. 5.0 Operating manual EN 5.1 Explanation of the push-buttons and LEDs A PinTherm Connect 06.29.108 MON 08:01 18ºC DAY X:060 H B D F C 0 E I G M RESET I A B C D E F G H I J K L M N O - OK N ESC O J K L Illuminated display (see also 5.2) Push-button for switching the heating mode on and off. LED, lit when the heating mode is active. Push-button for switching the continuous ventilation mode on and off. LED, lit when the continuous ventilation mode is active. Push-button for switching the appliance out of lock-out after a (burner) fault. LED, lit when a (burner) fault has been detected. Push-button for activating the user menu or to display the next value. Push-button for confirming a selection/change or for displaying the next menu item. Push-button for exiting the setting or menu without executing a change. Push-button for switching the overtime timer on and off. Push-button ๏€ต+๏€ถ­– to change a setting. LED, lit when there is heat demand in the heating mode (burner on). LED, lit when the fan is switched on. LED, lit when the overtime timer function is active. 7 5.2 Explanation of the display B A MA C 08:01 18ºC DAG X:060 D E A B C D E Indicates the day of the week. The current clock time is shown here. Indicates the measured temperature (°C). Indicates the number of minutes before the overtime timer function is switched off again and the PinTherm Connect will return to night temperature control mode. Indicates whether the PinTherm Connect is set to daytime mode (DAY) or to night mode (NIGHT) and temperature control based on the daytime or night temperature setting. 5.3 Initial operation of the PinTherm Connect When you connect a power supply to the PinTherm Connect for the first time, you will be asked to select your choice of language (language settings: NL, EN, DE, FR, PL, RO, LT). Having done so, the next step is to set the time and date. After the time and date have been set, the PinTherm Connect displays the main screen. SELECT LANGUAGE ENGLISH OK SAT 01-01-2006 00:00:00 select the desired language changes the flashing digit to go one digit up MON Language options: NL, EN, DE, FR, PL, RO, LT 8 08:00 DAY 16°C OK 5.4 Activate user menu MON 08:01 DAY °C OK ENTER MENU CODE 0000 EN OK changes the flashing digit Default setting Menu code 1000 to go one digit up SET/CHANGE PROGRAM make your menu choice with these buttons ESC leave the menu and go back to the main screen You can change the following settings in the menu: – Enter/change switching times – Change day/night setting – Change time/date – Vacation settings – Change menu code – Change language – Calibration – 0-10V min 0-5V – 0-10V max 5-10V – 0-10V range (1-3) – Modbus – IP settings 5.5 Enter or change switching times SET/CHANGE PROGRAM OK MONDAY 1 07:30 -> 17:00 OK MONDAY 2 --:-- -> --:-- OK changes the flashing digit to go up one digit MONDAY 3 --:-- -> --:-changes the flashing digit OK TUESDAY 1 07:30 -> 17:00 etc. SUNDAY 3 --:-- -> --:-- OK back to the menu to go up one digit 9 5.6 Change day/night temperature setting select SET/CHANGE TEMPERATURE OK DAY SETTING 18°C OK changes the flashing digit to go one digit up NIGHT SETTING 08°C changes the flashing digit OK back to the menu to go one digit up 5.7 Change time and date select CHANGE TIME/DATE OK MON 23-03-2009 09:10:00 changes the flashing digit OK back to the menu to go one digit up 5.8 Vacation settings During the set time block, the control will regulate according to the night temperature. select VACATION SETTING OK VACATION ACTIVE ON OK FROM: 01-07-2017 TILL: 01-08-2017 select on or off changes the flashing light to go up one digit 5.9 Change menu code select CHANGE MENU CODE OK SELECT NEW CODE 1000 changes the flashing digit to go one digit up New menu code 10 OK back to the menu OK back to the menu 5.10 Change language select CHANGE LANGUAGE EN OK SELECT LANGUAGE ENGLISH select the desired language OK back to the menu Language options: NL, EN, DE, FR, PL, RO, LT. 5.11 Calibration temperature If the external room sensor is installed in an unfavourable position, the actual temperature and the temperature measured by the PinTherm Connect may differ. This temperature difference can be compensated by setting a correction factor in this temperature calibration function. For example: select The measured temperature is 18°C, but the PinTherm Connect display indicates 20°C. The difference in this example is 2°C too high. The correction value must be set to -2°C. CALIB. TEMP. OK CALIB. TEMP. + 0.0°C changes the flashing digit OK back to the menu to go one digit up Correctionvalue is adjustable from -3,5°C to +3,5°C 5.12 Heating/Cooling select HEATING/COOLING OK HEATING/COOLING HEATING change setting OK back to the menu Setting to make the controller suitable for controlling heating or cooling. 11 5.13 Switching difference select SWITCHING DIFF. OK SWITCHING DIFF. 1.0K OK back to the menu changes the flashing digit Adjustable between 0.1 and 3.0 K. 5.14 Change minimum control signal select 0-10V min(0-5V) 0-10V min(0-5V) 2.0 V OK change setting OK back to the menu Note: When there is no demand for heat, the PinTherm Connect sends out a signal of 0VDC. 5.15 Change maximum control signal select 0-10V max(5-10V) OK 0-10V max(5-10V) 10.0 V change setting OK back to the menu 5.16 Change control signal range select 0-10V Range(1-3) OK 0-10V Range(1-3) 1.0 change setting OK back to the menu This function determines when the 0 – 10VDC signal is modulated back in conditions of heat demand. When set to 1.0, the PinTherm Connect will start to modulate the 0 - 10V signal at 1K below the target temperature. The range can be set between 0.5 – 3.0 and is set to 1.0 as standard. ­­­ 12 5.17 ModBus select MODBUS SETTINGS OK MODBUS SETTINGS 001 changes the flashing digit EN OK back to the menu to go one digit up Slave ID: adjustable 1 - 247 Factory setting: 1 5.18 Ethernet Info select ETHERNET INFO OK IP ADDRESS 192.168.001.100 OK MAC ADDRESS 5410EC220037 OK back to the menu Display set IP address. 5.19 IP settings select IP SETTINGS OK IP MODE STATIQ OK change setting IP ADDRESS 192.168.001.100 SUBNET MASK 255.255.255.000 changes the flashing digit changes the flashing digit to go one digit up to go one digit up OK back to the menu DHCP - automatic assignment IP address Static - set fixed IP address SUBnet Mask 5.20 Switch overtime timer on/off This function provides the option of manually switching to the daytime temperature outside the set switching times for a period of 1, 2 or 3 hours. The yellow LED with the symbol is lit when this function is active. In addition, the bottom right of the display shows the time in minutes that still remains before the function is deactivated and the PinTherm Connect returns to night temperature control. The function can also be switched off prematurely by pressing the push-button again until the yellow LED extinguishes and the number of remaining minutes disappears from the display. 13 See the illustration below. MON 17:01 NIGHT 18°C MON 17:01 18°C DAY X:060 MON 17:01 18°C DAY X:120 MON 17:01 18°C DAY X:180 5.21 Switch on chimney-sweep function You can use this function to switch the appliance temporarily to full heat output/partial heat output so that measurements can be taken. Refer to the information below for instructions on how to switch this function on and off. After activation, this function remains switched on for 15 minutes and will switch off automatically again after that period. 0-10V 0 10V 14:59 Press and hold down Use the push-buttons referred to below to have the for ±12 seconds appliance run at a lower voltage (reduce the heat output) press to increase the voltage (maximum of 10V) press to lower the voltage ESC This switches the function off and takes you back to the main screen 5.22 Restore factory settings PinTherm Connect All the factory settings are restored when you activate this function. This function may be activated at any time. See the illustration below. OK keep pressed or +/- 12 secs RESET TO DEFAULT SETTINGS? OK DEFAULT SETTINGS RESTORED! SELECT LANGUAGE ENGLISH ESC This will return you to the screen from which you selected this function and default settings will not be restored. MON 08:01 DAY 16°C 6.0 Disposing of the PinTherm Connect When the PinTherm Connect is replaced or removed, it must be recycled or destroyed in accordance with national and/or local legislation and regulations. 7.0 Modbus - Communication [12] - Modbus-list [13] 14 8.0 PinTherm Connect connections EN PinTherm Connect 06.29.108 MON 08:01 DAY 18ºC X:060 0 I RESET OK ESC L N Connection terminals (230Vac/50Hz) 21 - 22 Continuous ventilation 21 - 23 Heating/cooling 24 - 25 Fault signal 25 - 26 Reset + - 0-10Vdc (Heating/cooling) 11 - 12 External room sensor A - B MODBUS RTU (R ground) RJ 45 connector Internet / Modbus TCP/IP 13 - 14 Contact external fan Warning: Dangerous voltage present on N, L, 13, 14, 21, 22, 23, 24, 25 and 26 With the PinTherm Connect, only devices that comply with the safety regulations as laid down in EN-IEC 61010-1 may be controlled. 15 Lesen Sie dieses Dokument sorgfältig durch, bevor Sie das Gerät installieren Warnhinweis Fehlerhaft durchgeführte Installationen, Einstellungen, Änderungen, Reparaturen oder Wartungsmaßnahmen können zu Sachschäden und Verletzungen führen. Alle Arbeiten müssen von geprüften, qualifizierten Fachleuten durchgeführt werden. Falls das Gerät nicht vorschriftsgemäß aufgestellt wird, erlischt die Garantie. Dieses Gerät ist nicht für den Gebrauch durch Personen (einschließlich Kindern) mit verminderter körperlicher, Sinnes- oder geistiger Leistungsfähigkeit oder mangelnder Erfahrung und mangelnden Kenntnissen bestimmt, sofern sie nicht unter Aufsicht stehen oder durch eine Person, die für ihre Sicherheit verantwortlich ist, im Gebrauch des Geräts angeleitet werden. Kinder müssen vom Gerät ferngehalten werden. 16 1.0 Inhalt 2.0 Allgemeines 2.1 Änderungen vorbehalten 2.2 Allgemeine Warnhinweise Seite Seite 18 18 3.0 Technische Daten 3.1 Technische Daten PinTherm Connect 3.2 Technische Daten externer Raumfühler (optional) 3.3 Widerstandstabelle (externer) Raumfühler 3.4 Werkseinstellungen PinTherm Connect Seite Seite Seite Seite 18 19 19 19 4.0 Montage 4.1 Allgemeines 4.2 Montage PinTherm Connect 4.3 Montage eines externen Raumfühlers (optional) Seite Seite Seite 20 20 20 5.0 Bedienungsanleitung 5.1 Erläuterung der Drucktasten und LEDs Seite 5.2 Erläuterung des Displays Seite 5.3 Erste Inbetriebnahme der PinTherm Connect Seite 5.4 Aktivierung des Benutzermenüs Seite 5.5 Schaltzeiten eingeben oder ändern Seite 5.6 Tages- und Nachttemperatur ändern Seite 5.7 Uhrzeit und Datum ändern Seite 5.8 Einstellung der Urlaubsreglung Seite 5.9 Menücode ändern Seite 5.10 Sprachauswahl ändern Seite 5.11 Justierung Seite 5.12 Heizen / Kühlen Seite 5.13 Schaltdifferenz Seite 5.14 Minimumregelsignal ändern Seite 5.15 Maximumregelsignal ändern Seite 5.16 Bereich Minimumregelsignal ändern Seite 5.17 Modbus Seite 5.18 Ethernet Info Seite 5.19 IP-Einstellungen Seite 5.20 Überstundenzähler ein-/ausschalten Seite 5.21 Schornsteinfegerfunktion einschalten Seite 5.22 Werkseinstellungen der PinTherm Connect wiederherstellen Seite 21 22 22 23 23 24 24 24 24 25 25 25 26 26 26 26 27 27 27 27 28 28 6.0 Entsorgung der PinTherm Connect Seite 28 7.0 Modbus Seite 28 8.0 Anschlussmöglichkeiten der PinTherm Connect Seite 29 Anhang I Anschlussschema Anhang II Modbus Seite Seite 87 94 DE 17 2.0 Allgemeines 2.1 Änderungen vorbehalten Der Hersteller strebt eine kontinuierliche Verbesserung der Produkte an und behält sich das Recht vor, ohne vorherige Mitteilung, Änderungen an den technischen Daten vorzunehmen. Die technischen Angaben werden als korrekt angenommen, bilden aber keine Grundlage für einen Vertrag oder Gewährleistungsansprüche. Alle Bestellungen werden gemäß den Standardkonditionen in unseren allgemeinen Verkaufs- und Lieferbedingungen angenommen (diese werden auf Anfrage zur Verfügung gestellt). 2.2 Allgemeine Warnhinweise Die Installation muss den geltenden landesweiten und örtlichen Bestimmungen entsprechen. Daher darf das Gerät nur von einem sachkundigen und qualifizierten Installateur unter Beachtung der nationalen und internationalen Vorschriften installiert werden. Im Falle einer unsachgemäßen Installation, Einstellung, Änderung, Wartung oder Instandsetzung erlischt die Gewährleistung. Vor dem Aufschrauben der Klemmen immer die 230V-Stromversorgung ausschalten. Die Netzspannung am PinTherm Connect muss durch einen permanenten Schalter, der für 250VAC / 10A geeignet ist und die geltenden Sicherheitsvorschriften erfüllt, zweipolig abgeschaltet werden können. Nur Geräte, die EN-IEC 61010-1 entsprechen, dürfen mit dem PinTherm Connect betrieben werden. Reinigen Sie das Gehäuse des PinTherm Connect mit einem feuchten Tuch. Keine Lösungsmittel auftragen. Es gibt keine Anforderungen an die Belüftung in unmittelbarer Nähe des Reglers. Warnung - Gefahr eines Stromschlags. ! Warnung - Allgemeine Warnung Die Stromanschlüsse können an den Anschlussklemmen vorgenommen werden, an denen sich einer befindet. ! 3.0 Technische Daten 3.1 Technische Daten PinTherm Connect • Typbezeichnung : PinTherm Connect • Artikelnummer : 06 29 108 • Spannungsversorgung : 90 – 240 VAC / 47-63Hz • Eigenverbrauch : < 9W • Uhr : 24 Std. Uhr mit automatischer Umstellung auf Sommer und Winterzeit • Schaltprogramm : 3 Schaltprogramme pro Tag • Schaltdifferenz : 0,1 - 3K • Größe : 166 x 160 x 106mm (LxBxH) • Gewicht : 880 Gramm • Schutzart : IP54 • Installationsumgebung : Transport / Lagerung: -20 ° C bis + 70 ° C Betrieb: -10 ° C bis + 60 ° C Relative Luftfeuchtigkeit: 0-90% nicht kondensierend Installation maximal 2000 Meter über dem Meeresspiegel. 18 • Überspannungskategorie : • Verschmutzungsgrad : • Schaltkontakt:* : • Temperatureinstellung : • Überstunden-Timer : • Kalibrierung : • Heizen /Kühlen : • 0-10 VDC : • Fühler : • Einstellbare Sprachen : • Vorsicherung : 11 2 Heizung: 230Vac/16A (4A) Andere: 230Vac/10A (2,5A) 0 bis 39 °C pro 1°C einstellbar einstellbar 1, 2 oder 3 Stunden (060,120,180) einstellbar von -3,5 ° C bis + 3,5 ° C Umschaltkontakt zum Heizen oder Kühlen 0-10 VDC Ausgang zum Heizen oder Kühlen externer Raumfühler (06 29 086) NL/EN/DE/FR/PL/RO/LT 6A DE * Die Relaiskontakte sind Funktionsschalter, keine Sicherheitsschalter. 3.2 Technische Daten externer Raumfühler (optional) • Typbezeichnung : RSTF NTC4,7K • Artikelnummer : 06 29 086 • Widerstand : NTC 4K7 • Abmessungen : 79 x 81 x 26mm (L x B x H) • Gewicht : 46 Gramm • Elektrischer Anschluss : 0.75 -1.5mm² • Schutzgrad : IP-30 3.3 Widerstandstabelle (externer) Raumfühler -15°C -10°C -5°C 32.937kโ„ฆ 25.217kโ„ฆ 19.392kโ„ฆ 0°C 15.040kโ„ฆ 5°C 11.743kโ„ฆ 10°C 9.241kโ„ฆ 15°C 7.330kโ„ฆ 20°C 5.855kโ„ฆ 35°C 3.071kโ„ฆ 40°C 2.512kโ„ฆ 45°C 2.066kโ„ฆ 50°C 1.709kโ„ฆ 25°C 4.700kโ„ฆ 30°C 3.777kโ„ฆ 3.4 Werkseinstellungen PinTherm Connect • Menücode : 1000 • Schaltzeiten : MA, DI, WO, DO, VR 07:30-17:30 Uhr ZA, ZO 00:00-00:00 Uhr • Raumtemperatur : Tagestemperatur 18°C Nachttemperatur 08°C • Justierung : +0.0 • Schaltdifferenz : 1K • Heizen / Kühlen : Heizen • 0-10V range : 1K • 0-10V min : 0V • 0-10V max : 10V • Modbus : Slave ID 001 • IP-Einstellungen : statisch 19 4.0 Montage 4.1 Allgemeines Prüfen Sie nach dem auspacken der PinTherm Connect und - falls bestellt - den mitgelieferten externen Raumfühler auf Beschädigungen. Überprüfen Sie die Richtigkeit des gelieferten Typs/ Models sowie die elektrische Spannung. 4.2 Montage des PinTherm Connect Legen Sie einen geeigneten Ort für den Einbau der PinTherm Connect fest. Montieren Sie den PinTherm Connect auf einer Oberfläche, die mindestens 4kg tragen kann. Es wird empfohlen, die PinTherm Connect auf ± 1,5 m über dem Fußboden anzubringen, an einem leicht zugänglichen Ort. Verwenden Sie für die Kabeleinführung nur Kabelverschraubungen mit einen Zugentlastung der Mindestbrandklasse UL94V2. Stellen Sie sicher, dass die Stromversorgung ausgeschaltet ist, bevor Sie ein Kabel anschließen. Sollte dies nicht der Fall sein, muss die Stromversorgung ausgeschaltet werden. Beziehen Sie vor dem Ausschalten der Stromversorgung auf die jeweilige Bedienungsanleitung des Gerätes. Schließen Sie den PinTherm Connect gemäß einem der mitgelieferten Schaltpläne an. Diese finden Sie auf der Rückseite des technischen Handbuchs. Um das richtige Verbindungsdiagramm auszuwählen, müssen Sie wissen, an welchem Gerätetyp Sie den PinTherm Connect anschließen. Für eine Auswahl siehe auch Anhang I. Wenn ein 0-10VDC-Signal angelegt wird, Siehe nachfolgende Tabelle für den richtigen Kabeldurchmesser und die richtige Länge. Durchmesser 0.8mm2 1.0mm2 1.5mm2 Länge 80 m 100 m 150 m Es wird empfohlen, hierfür ein geschirmtes Kabel zu verwenden. 4.3 Montage eines externen Raumfühlers (optional) Platzieren Sie den externen Raumfühler geschützt in Sichtweite des Gerätes in einer Höhe von ca. 1,5 Meter, gemessen ab dem Boden. Schließen Sie den Sensor an die entsprechenden Klemmen im PinTherm Connect an. Siehe nachfolgende Tabelle für den richtigen Kabeldurchmesser und die richtige Länge. Durchmesser 0.8mm2 1.0mm2 1.5mm2 20 Länge 80 m 100 m 150 m Es wird empfohlen, hierfür ein geschirmtes Kabel zu verwenden. 5.0 Bedienungsanleitung 5.1 Erläuterung der Drucktasten und LEDs DE A PinTherm Connect 06.29.108 MO 08:01 18ºC TAG X:060 H B D F C 0 E I G M RESET I A B C D E F G H I J K L M N O - OK N ESC O J K L Beleuchtete Anzeige (siehe auch 5.2) Drucktaste zum Ein- oder Ausschalten der Erwärmungsstufe. LED leuchtet auf, wenn die Funktion „Erwärmen” eingeschaltet ist. Drucktaste zum Ein- und Ausschalten der Stellung Lüften. Die LED leuchtet auf, wenn die Lüftungsfunktion eingeschaltet ist. Drucktaste, um das Gerät im Fall einer (Brenner-)Störung zu entsperren. LED leuchtet im Fall einer (Brenner-)Störung. Drucktaste, um das Benutzermenü zu aktivieren oder um zum nächsten Punkt zu gehen. Drucktaste, um eine durchgeführte Wahl/Änderung zu bestätigen oder um zum nächsten Menüpunkt zu gehen. Drucktaste, um das Menü oder die Eiinstellung zu verlassen, ohne eine Änderung durch zuführen. Drucktaste, um den Überstundenzähler ein- oder auszuschalten. Schaltfläche ๏€ต+๏€ถ­– um eine Einstellung zu ändern. LED leuchtet bei Wärmebedarf in der Stufe Erwärmen (Brenner ein) auf. Die LED leuchtet auf, wenn der Lüfter eingeschaltet ist. LED leuchtet auf, wenn die Funktion Überstundenzähler eingeschaltet ist. 21 5.2 Erläuterung des Displays B A MO C 08:01 18ºC TAG X:060 D E A B C D E Zeigt den Wochentag an. Zeigt die aktuelle Uhrzeit an. Zeigt die gemessene Temperatur (°C) an. Zeigt die Anzahl der Minuten an, bevor die Funktion Überstundenzähler wieder ausgeschaltet wird und die PinTherm Connect in der Nachttemperaturstellung arbeitet. Zeigt an, ob die PinTherm Connect in der Tagesstellung (TAG) oder Nachtstellung (NACHT) steht und in der Tag- oder Nachttemperaturstellung arbeitet. 5.3 Erste Inbetriebnahme der PinTherm Connect Wenn Sie die PinTherm Connect das erste Mal einschalten, werden Sie aufgefordert, die gewünschte Sprache zu wählen (einstellbare Sprachen: Niederländisch, Englisch, Deutsch, Französisch, Italienisch und Polnisch). Anschließend müssen Sie Zeit und Datum einstellen. Dann kehrt die PinTherm Connect zum Hauptbildschirm zurück. SELECT LANGUAGE ENGLISH OK SA 01-01-2006 00:00:00 Gewünschte Sprache uswählen Ändert die blinkende Ziffer Zur folgende Ziffer gehen MO Einstellbare Sprachen: NL, EN, DE, FR, PL, RO, LT 22 08:00 TAG 16°C OK 5.4 Aktivierung des Benutzermenüs MO °C 08:01 TAG OK CODE EINGEBEN 0000 OK DE Ändert die blinkende Ziffer Menücode werkeinstellung 1000 Zur folgende Ziffer gehen PROGRAMM EINGEBEN/ANDERN Hiermit treffen Sie die gewünschte Wahl in Menü. ESC das Menü verlassen und zum Hauptbildschirm zurückkehren Im Menü können die folgenden Einstellungen vorgenommen werden: – Schaltzeiten eingeben/ändern – Tages- und Nachttemperatur ändern – Uhrzeit/Datum ändern – Urlaubsreglung – Menücode ändern – Sprachauswahl ändern – Justierung – 0-10V min 0-5V – 0-10V max 5-10V – 0-10V range (1-3) – Modbus – IP-Einstellungen 5.5 Schaltzeiten eingeben oder ändern PROGRAMM EINGEBEN/ÄNDERN OK MONTAG 1 07:30 -> 17:00 OK MONTAG 2 --:-- -> --:-- OK Ändert die blinkende Ziffer Zur folgende Ziffer gehen MONTAG 3 --:-- -> --:-Ändert die blinkende Ziffer OK DIENSTAG 1 07:30 -> 17:00 usw. SONNTAG 3 --:-- -> --:-- OK zurück zum Menü Zur folgende Ziffer gehen 23 5.6 Tages- und Nachttemperatur ändern auswählen SOLLTEMPERATUR TAGESTEMPERATUR 18°C OK OK Ändert die blinkende Ziffer Zur folgende Ziffer gehen NACHTTEMPERATUR 08°C OK zurück zum Menü Ändert die blinkende Ziffer Zur folgende Ziffer gehen 5.7 Uhrzeit und Datum ändern auswählen DATUM/ZEIT ÄNDERN MO 23-03-2009 09:10:00 OK OK zurück zum Menü Ändert die blinkende Ziffer Zur folgende Ziffer gehen 5.8 Einstellung der Urlaubsreglung auswählen URLAUBSEINSTELLUNG OK URL.EINST.AKTIV AN OK VON: 01-07-2017 BIS: 01-08-2017 Wählen Sie den Ein oder Aus Ändert die blinkende Ziffer OK zurück zum Menü Zur folgende Ziffer gehen Während des eingestellten Zeitblocks regelt die Steuerung entsprechend die Nachttemperatur. 5.9 Menücode ändern auswählen CODE ÄNDERN OK CODE NEU WÄHLEN 1000 Ändert die blinkende Ziffer Zur folgende Ziffer gehen Neuer Menücode 24 OK zurück zum Menü 5.10 Sprachauswahl ändern auswählen SPRACHE ÄNDERN OK SPRACHE WÄHLEN DEUTSCH Gewünschte Sprache uswählen DE OK zurück zum Menü Einstellbare Sprachen: NL, EN, DE, FR, PL, RO, LT. 5.11 Justierung Wenn die PinTherm Connect an einem ungeeigneten Ort montiert wird, kann eine Abweichung gegenüber der tatsächlich gemessenen PinTherm Connect-Temperatur auftreten. Dieser Temperaturunterschied kann mit der Kalibrierungsfunktion angepasst werden, indem ein Korrekturwert eingestellt wird. Beispiel: Die gemessene Temperatur beträgt 18 °C, der Bildschirm auf der Pin Therm+ zeigt 20 °C an. Die Differenz beträgt in diesem Beispiel also 2 °C zu viel als Korrekturwert muss -2° C eingestellt werden. auswählen KALIB. TEMP. OK KALIB. TEMP. + 0.0°C Ändert die blinkende Ziffer OK zurück zum Menü Zur folgende Ziffer gehen Korrekturwert ist einstellbar von -3,5°C bis +3,5°C 5.12 Heizen / Kühlen HEIZEN/KUHLEN auswählen OK HEIZEN/KUHLEN HEIZEN Einstellung ändern OK zurück zum Menü Einstellug des Reglers zum Heizen oder Kühlen. 25 5.13 Schaltdifferenz auswählen SCHALTDIFFERENZ OK SCHALTDIFFERENZ 1.0K Ändert die blinkende Ziffer OK zurück zum Menü Einstellbar zwischen 0,1 und 3,0 K. 5.14 Minimumregelsignal ändern auswählen 0-10V min(0-5V) OK 0-10V min(0-5V) 2.0 V Einstellung ändern OK zurück zum Menü Anmerkung: Wenn keine Wärmeanforderung vorliegt, sendet das PinTherm Connect 0 VDC. 5.15 Maximumregelsignal ändern auswählen 0-10V max(5-10V) OK 0-10V max(5-10V) 10.0 V Einstellung ändern OK zurück zum Menü 5.16 Bereich Minimumregelsignal ändern auswählen 0-10V Bereich (1-3) OK 0-10V Bereich (1-3) 1.0 Einstellung ändern OK zurück zum Menü Mit dieser Funktion wird festgelegt, wann das 0-10 VDC-Signal während einer Wärmeanforderung zurückmoduliert wird. Wenn dies auf 1,0 eingestellt ist, wird die PinTherm Connect 1K unter der Solltemperatur das 0-10 V-Signal zurückmodulieren. Der Bereich ist einstellbar von 0,5 – 3,0 und ist standardmäßig auf 1,0 eingestellt. ­­­ 26 5.17 ModBus auswählen MODBUS EINSTELLUNG OK MODBUS SLAVE ID 001 Ändert die blinkende Ziffer OK DE zurück zum Menü Zur folgende Ziffer gehen Slave-ID: einstellbar 1 - 247 Werkseinstellung: 1 5.18 Ethernet Info auswählen ETHERNET INFO (LAN) OK IP-ADRESSE 192.168.001.100 OK MAC ADRESSE 5410EC220037 OK zurück zum Menü Zeigt die eingestellte IP-Adresse an. 5.19 IP-Einstellungen auswählen IP EINSTELLUNG OK IP MODUS STATISCH OK Einstellung ändern IP-ADRESSE 192.168.001.100 SUBNETZMASKE 255.255.255.000 Ändert die blinkende Ziffer Ändert die blinkende Ziffer Zur folgende Ziffer gehen Zur folgende Ziffer gehen OK zurück zum Menü DHCP - automatische Zuweisung der IP-Adresse Statisch - festeingestellte IP Adresse SUBnet Maske 5.20 Überstundenzähler ein-/ausschalten Mit dieser Funktion kann man ungeachtet der eingestellten Schaltzeiten manuell 1, 2 oder 3 Stunden auf die Tagestemperatur umschalten. Die gelbe LED Anzeige mit dem Symbol leuchtet, wenn diese Funktion eingeschaltet ist. Weiterhin wird auf dem Display rechts unten die verbleibende Zeit in Minuten angezeigt, bevor die Funktion wieder ausschaltet und die PinTherm Connect wieder mit der Nachttemperatur arbeitet. Die Funktion kann auch zwischenzeitlich wieder ausgeschaltet werden, indem die Drucktaste nochmals gedrückt wird, bis die gelbe LED Anzeige erlischt und die Anzahl der Minuten nicht 27 mehr auf dem Display angezeigt wird. Siehe folgende Abbildung. MO 17:01 NACHT 18°C MO 17:01 18°C TAG X:060 MO 17:01 18°C TAG X:120 MO 17:01 18°C TAG X:180 5.21 Schornsteinfegerfunktion einschalten 0-10V 0 ca. 12 s gedrückt halten 10V 14:59 Verwenden Sie die nachfolgenden Drucktasten, um das Gerät mit einer niedrigeren Spannung (Teillast) laufen zu lassen. drücken, um die Spannung zu erhöhen (max. 10 V) drücken, um die Spannung zu erniedrigen ESC Hiermit beenden Sie die Funktion und kehren Sie zum Hauptbildschirm zurück Hiermit können Sie das Gerät kurzzeitig in Volllast/Teillast heizen lassen, um Messungen usw. durchführen zu können. Nachfolgend ist angegeben, wie Sie diese Funktion ein- und ausschalten können. Nach dem Einschalten bleibt diese Funktion 15 Minuten aktiv und schaltet sich anschließend automatisch wieder aus. 5.22 Werkseinstellungen der PinTherm Connect wiederherstellen Durch diese Funktion wird alles auf die Werkseinstellungen zurückgesetzt. Diese Funktion kann jederzeit ausgeführt werden. Siehe folgende Abbildung. OK ± 12 sek. Gedrückt halten WERKEINSTELLUNG HERSTELLEN? OK WERKEINSTELLUNG HERGESTELLT SELECT LANGUAGE ENGLISH ESC Hiermit kehren Sie zum Hauptbildschirm zurück. Und es wird nicht auf die Werkeinstellungen zurückgesetzt! MO 08:01 TAG 16°C 6.0 Entsorgung der PinTherm Connect Wenn das PinTherm Connect ersetzt oder entfernt wird, muss es gemäß den überregionalen oder lokalen Vorschriften entsorgt oder vernichtet werden. 7.0 Modbus - Kommunikation [12] - Modbus Liste [13] 28 8.0 Anschlussmöglichkeiten der PinTherm Connect DE PinTherm Connect 06.29.108 MO 08:01 TAG 18ºC X:060 0 I RESET OK ESC L N Anschlussklemmen (230Vac/50Hz) 21 - 22 Kontinuirliche Belüftung 21 - 23 Heizen / Kühlen 24 - 25 Störungsleuchte 25 - 26 Rücksetzkontakt + - 0-10Vdc (Heizen / Kühlen) 11 - 12 externer Raumfühler A - B MODBUS RTU (R ground) RJ 45 connector Internet / Modbus TCP/IP 13 - 14 Kontakt zum externen Ventilator Warnung: Gefährliche Spannung liegt bei N, L, 13, 14, 21, 22, 23, 24, 25 und 26 Mit dem PinTherm Connect dürfen nur Geräte gesteuert werden, die den Sicherheitsbestimmungen der EN-IEC 61010-1 entsprechen. 29 Lire attentivement ce document avant de commencer l’installation de l’appareil Avertissement Une installation, un réglage, une modification, une réparation ou un entretien mal exécuté(s) peut entraîner des dommages matériels ou des blessures. Tous les travaux doivent être exécutés par des professionnels reconnus et qualifiés. Lorsque l’appareil n’est pas installé suivant les prescriptions, la garantie échoit. Cet appareil n’est pas destiné à l’utilisation par des personnes (y compris des enfants) aux capacités physiques, sensorielles ou mentales amoindries, ou manquant d’expériences et de connaissances, sans surveillance ni instructions quant à l’utilisation de l’appareil par une personne responsable de leur sécurité. Il convient de surveiller les enfants afin de veiller à ce qu’ils ne jouent pas avec l’appareil. 30 1.0 Table des matières 2.0 Généralités 2.1 Modifications sous réserve 2.2 Avertissements généraux page page 32 32 FR 3.0 Données techniques 3.1 Données techniques PinTherm Connect 3.2 Données techniques sonde ambiante externe (en option) 3.3 Tableau de résistance (externe) de la sonde ambiante 3.4 Réglages d’usine PinTherm Connect page page page page 32 33 33 33 4.0 Installation 4.1 Généralités 4.2 Montage PinTherm Connect 4.3 Montage de la sonde ambiante externe (en option) page page page 34 34 34 5.0 Consigne d’installation 5.1 Explication des boutons poussoirs et des LEDs 5.2 Explication affichage 5.3 Première mise en service de PinTherm Connect 5.4 Activation du menu de l’utilisateur 5.5 Paramétrer ou modifier les délais de connexion 5.6 Modifier la température de jour/de nuit 5.7 Modifier la date et l’heure 5.8 Paramètres vacances 5.9 Modifier le code menu 5.10 Modifier le choix de la langue 5.11 Calibrage 5.12 Chauffage/climatisation 5.13 Différence de commutation 5.14 Modifier le signal d’erreur minimal 5.15 Modifier le signal d’erreur maximal 5.16 Modifier la plage de signal d’erreur 5.17 Modbus 5.18 Info Ethernet 5.19 Paramètres IP 5.20 Mettre en/hors service la minuterie supplémentaire 5.21 Mettre en service la fonction de ramonage de cheminée 5.22 Retour aux paramètres d’usine de PinTherm Connect page page page page page page page page page page page page page page page page page page page page page page 35 36 36 37 37 38 38 38 38 39 39 39 40 40 40 40 41 41 41 41 42 42 6.0 Destruction PinTherm Connect page 42 7.0 Modbus page 42 8.0 Possibilités de raccordement de PinTherm Connect page 43 Annexe I Schémas de câblage Annexe II Modbus page page 87 94 31 2.0 Généralités 2.1 Modifications sous réserve Le fabricant travaille sans relâche à l’amélioration des produits et se réserve le droit d’apporter des modifications dans les spécifications, sans avis préalable. Les détails techniques sont supposés être corrects mais ne constituent pas une base pour un contrat ou une garantie. Tous les ordres sont acceptés aux stipulations standard de nos conditions générales de vente et de livraison (disponibles sur demande). 2.2 Avertissements généraux L’installation doit répondre aux prescriptions nationales et/ou régionales en vigueur. Faites dès lors installer PinTherm Connect par un installateur compétent et qualifié en tentant compte de la législation nationale et internationale. En cas d’installation, de réglage, de modification, d’entretien ou de réparation erroné, la garantie échoit. Éteignez toujours l’alimentation électrique de 230V avant la connexion des terminaux. La tension de secteur sur le PinTherm Connect doit pouvoir être éteint d’une manière à deux pôles au moyen d’un commutateur permanent qui est approprié pour 250VAC / 10A et respecte les mesures de sécurité applicables. Seulsles dispositifs qui respectent EN-IEC 61010-1 peuvent être opérés avec le PinTherm Connect. Nettoyez le boitier du PinTherm Connect avec un tissu humide. N’appliquez pas de solvants. Il n’y a aucune exigence quant à la ventilation dans le voisinage immédiat du contrôleur. Avertissement – Risque d’électrochoc ! Avertissement - avertissement général, risque de danger. Il peut y avoir une tension sur les terminaux où il est placé. ! 3.0 Données techniques 3.1 Données techniques PinTherm Connect • Classification de l’unité : PinTherm Connect • Numéro d’article : 06 29 108 • Alimentation PinTherm Connect : 90 – 240 VAC / 47-63Hz • Consommation propre : < 9W • Horloge : 24 heures avec passage automatique heure d’été / heure d’hiver • Programmes de réglage : 3 programmes par jour • Plage de réglage différentielle : 0,1 - 3K • Dimensions : 166 x 160 x 106mm (Lxlxh) • Poids : 880 gramme • Degré de protection : IP-54 • Environnement d’installation : Transport/stockage: -20°C à +70°C. Opérationnel: -10°C à +60°C Humidité relative : 0-90% sans condensation Installation maximale à 2000 mètres au dessus du niveau de la mer. • Catégorie de surtension : 11 • Niveau de pollution : 2 32 • Contact de sélection* : • Plage de réglage de température : • Minuteur de prolongation : • Calibration : • Chauffer/refroidir : • 0-10 VDC : • Sonde : • Langue réglable : • Fusible : Chauffer: 230Vac/16A (4A) Autres: 230Vac/10A (2,5A) 0 à 39°C par paliers de 1°C réglable 1, 2 ou 3 heures (060, 120, 180) réglable de -3.5°C à +3.5°C Contact réversible pour le chauffage ou refroidissement sortie 0-10 VDC pour le chauffage ou refroidissement Sonde de température externe (06 29 086) NL/EN/DE/FR/PL/RO/LT 6A FR * Les contacts de relais sont des commutateurs fonctionnels, non des commutateurs de sécurité. 3.2 Données techniques sonde ambiante externe (en option) • Classification de l’unité : RSTF NTC4,7K • Numéro d’article : 06 29 086 • Résistance : NTC 4K7 • Dimensions : 79 x 81 x 26mm (Lxlxh) • Poids : 46 gram • Raccordement électrique : 0.75 -1.5mm² • Degré de protection : IP-30 3.3 Tableau de résistance (externe) de la sonde ambiante -15°C -10°C -5°C 32.937kโ„ฆ 25.217kโ„ฆ 19.392kโ„ฆ 0°C 15.040kโ„ฆ 5°C 11.743kโ„ฆ 10°C 9.241kโ„ฆ 15°C 7.330kโ„ฆ 20°C 5.855kโ„ฆ 35°C 3.071kโ„ฆ 40°C 2.512kโ„ฆ 45°C 2.066kโ„ฆ 50°C 1.709kโ„ฆ 25°C 4.700kโ„ฆ 30°C 3.777kโ„ฆ 3.4 Réglages d’usine PinTherm Connect • Code menu : 1000 • Délais de raccordemen : LU, MA, ME, JE, VE 07:30-17:30 heure SA, DI 00 :00-00 :00 heure • Température ambiante : Température du jour 18°C Température de nuit 08°C • Calibrage : +0.0 • Différence de commutation : 1K • Chauffage/climatisation : Chauffage • 0-10V plage : 1K • 0-10V min : 0V • 0-10V max : 10V • Modbus : Slave ID 001 • Paramètres IP : Statique 33 4.0 Installation 4.1 Généralités Contrôlez le PinTherm Connect après le déballage, et si commandée, la sonde ambiante externe livrée, pour voir s’ils ne sont pas endommagés. Contrôlez qu’il s’agit bien du bon type/modèle et de la bonne tension électrique. 4.2 Montage PinTherm Connect Déterminez un endroit adapté pour monter le PinTherm Connect. Monter le PinTherm Connect sur une surface solide qui peut soutenir au minimum 4kg. Il est conseillé de placer le Pin Therm+ à une distance de ± 1,5m du sol, à un endroit accessible. Pour le raccordement de câble, veuillez seulement utiliser des raccordements de câble adaptés avec un réducteur de tension et avec une classe de feu minimale d’UL94V2. Avant le raccordement du câble, contrôlez que la tension est bien déconnectée. Si ce n’est pas le cas, vous devez d’abord débrancher la tension avant de poursuivre. Lors de la déconnexion de la tension, de l’appareil à raccorder, il convient de tenir également compte du livret technique/du manuel de commande de l’appareil. Connectez le PinTherm Connect selon l ‘un des diagrammes électriques fournis qui se trouvent derrière ce livre technique. Pour choisir le diagramme de connexion correct, vous devez savoir sur quel type de dispositif vous connecterez le PinTherm Connect. Pour une sélection voir aussi l’Annexe I. Quand vous utilisez un signal 0-10DC, voyez le tableau ci-dessous pour la bonne longueur et le bon diamètre de câble. Diamètre 0.8mm2 1.0mm2 1.5mm2 Longueur 80 mètres 100 mètres 150 mètres Il est conseillé d’utiliser à cet effet un câble blindé. 4.3 Montage de la sonde ambiante externe (en option) Placez le capteur externe sans contingent, en vue de l’appareil à une hauteur d’approximativement 1.5m du plancher. Et joignez le capteur aux terminaux appropriés dans le PinTherm Connect. Voyez le tableau ci-dessous pour la bonne longueur et le bon diamètre de câble. Diamètre 0.8mm2 1.0mm2 1.5mm2 34 Longueur 80 mètres 100 mètres 150 mètres Il est conseillé d’utiliser à cet effet un câble blindé. 5.0 Consigne d’installation 5.1 Explication des boutons poussoirs et des LEDs A FR PinTherm Connect 06.29.108 LU 08:01 18ºC JOUR X:060 H B D F C 0 E I G M RESET I A B C D E F G H I J K L M N O - OK N ESC O J K L Affichage éclairé (voir également 5.2) Bouton poussoir mettre en service/hors service la position de chauffage. Lumière LED qui s’allume lorsque la fonction de chauffage est enclenchée. Bouton poussoir mettre en service/hors service la position de chauffage. Lumière LED qui s’allume lorsque la fonction de ventilation est enclenchée. Bouton poussoir destiné à déverrouiller l’appareil en cas de panne (de brûleur). La LED s’allume en cas de panne (de brûleur) Bouton poussoir pour activer le menu utilisateur ou pour aller au chiffre suivant. Bouton poussoir pour confirmer un choix/une modification effectué(e) ou pour aller vers l’article suivant du menu. Bouton poussoir pour quitter le menu ou le paramétrage sans effectuer de modification. Bouton poussoir pour mettre en/hors service la minuterie supplémentaire. Bouton poussoir ๏€ต+๏€ถ­– pour modifier un paramètre. La LED s’allume en cas de demande de chaleur dans la position chauffage (brûleur allumé). La LED s’allume quand le ventilateur est enclenché. La LED s’allume lorsque la fonction minuterie supplémentaire est enclenchée. 35 5.2 Explication affichage B A LU C 08:01 18ºC JOUR X:060 D E A B C D E Indique le jour de la semaine. L’heure réelle de l’horloge s’affiche ici. Donne la température mesurée (°C). Indique le nombre de minutes avant que la fonction de minuterie supplémentaire ne soit mise hors service et que le Pin Therm+ passe de nouveau sur la température de nuit. Indique si le PinTherm Connect est en position de jour (JOUR) ou en position de nuit (NUIT) et régule sur la base de la température de jour ou de nuit. 5.3 Première mise en service de PinTherm Connect Quand vous mettez le PinTherm Connect sous tension pour la première fois, il vous sera demandé de sélectionner la langue souhaitée (choix de langue : NL, EN, DE, FR, PL, RO, LT), ensuite, vous devez régler la date et l’heure. Ensuite, PinTherm Connect retourne à l’écran principal. SELECT LANGUAGE ENGLISH OK SA 01-01-2006 00:00:00 sélectionnez la langue désirée modifier la valeur qui clignote passer au chiffre suivant LU Langues au choix : NL, EN, DE, FR, PL, RO, LT 36 08:00 JOUR 16°C OK 5.4 Activation du menu de l’utilisateur LU 08:01 JOUR °C OK INTRODUIRE CODE 0000 OK modifier la valeur qui clignote Le code de menu est réglé par défaut sur 1000 FR passer au chiffre suivant RENTRER/CHANCER HEURES COMMUNAT sélectionner le menu correspondant ESC quitter le menu et revenir à l'écran principal Dans le menu, vous pouvez modifier les paramétrages suivants: – Saisir/modifier les délais de raccordement – Modifier la température de jour/nuit – Modifier l’heure/la date – Paramètres vacances – Modifier le code menu – Modifier le choix de la langue – Calibrage – 0-10V min 0-5V – 0-10V max 5-10V – 0-10V range (1-3) – Modbus – Paramètres IP 5.5 Paramétrer ou modifier les délais de connexion RENTRER/CHANGER HEURES COMMUNAT OK LUNDI 1 07:30 -> 17:00 OK LUNDI 2 --:-- -> --:-- OK modifier la valeur qui clignote passer au chiffre suivant LUNDI 3 --:-- -> --:-modifier la valeur qui clignote OK MARDI 1 07:30 -> 17:00 etc DIMANCHE 3 --:-- -> --:-- OK revenir au menu passer au chiffre suivant 37 5.6 Modifier la température de jour/de nuit sélectionner TEMPERATURE SOUHAITEE OK TEMPERATURE JOUR 18°C OK modifier la valeur qui clignote passer au chiffre suivant TEMPERATURE NUIT 08°C modifier la valeur qui clignote OK revenir au menu passer au chiffre suivant 5.7 Modifier la date et l’heure sélectionner MODIFIER HEURE/DATE OK LU 23-03-2009 09:10:00 OK revenir au menu modifier la valeur qui clignote passer au chiffre suivant 5.8 Paramètres de vacances Pendant le bloc de temps, le contrôle se réglera selon la température de nuit. sélectionner PROGRAMMATION VACANCES OK VACANCES ACTIF ON OK DU: 01-07-2017 AU: 01-08-2017 selectionner on ou off (allumé/éteind) modifier la valeur qui clignote passer au chiffre suivant 5.9 Modifier le code menu sélectionner MODIFIER CODE MENU OK CHOISIR CODE 1000 modifier la valeur qui clignote passer au chiffre suivant Nouveau code de menu 38 OK revenir au menu OK revenir au menu 5.10 Modifier le choix de la langue sélectionner MODIFIER LANGUE OK CHOIX LANGUE FRANCAIS sélectionnez la langue désirée OK revenir au menu FR Langues au choix : NL, EN, DE, FR, PL, RO, LT. 5.11 Calibrage En cas d’emplacement de montage défavorable du PinTherm Connect, on peut assister à une divergence par rapport à la température réellement mesurée parle PinTherm Connect. La fonction de calibrage de la température permet de compenser cet écart de température via la saisie d’une valeur de correction. Quand ce n’est pas suffisant, vous pouvez également choisir de raccorder une sonde ambiante externe au PinTherm Connect. Exemple: La température mesurée atteint 18 °C, l’écran sur le PinTherm Connect affiche 20 °C. La différence atteint donc dans cet exemple 2 °C de trop la valeur de correction doit alors être réglée sur -2 °C. sélectionner CALIBRAGE TEMP. OK CALIBRAGE TEMP. + 0.0°C modifier la valeur qui clignote OK revenir au menu passer au chiffre suivant Valeur de correction est réglable de -3,5°C jusqu'à +3,5°C 5.12 Chauffage/climatisation sélectionner CHAUF./REFROIDIR OK CHAUF./REFROIDIR CHAUFFER modifier le paramètre OK revenir au menu Réglez pour que le contrôleur soit prêt pour contrôler le chauffage ou la climatisation. 39 5.13 Différence de commutation sélectionner DIFF. D'ECHANGE OK DIFF. D'ECHANGE 1.0K OK revenir au menu modifier la valeur qui clignote Réglable entre 0,1 et 3,0 K. 5.14 Modifier le signal d’erreur minimal sélectionnez 0-10V min(0-5V) OK 0-10V min(0-5V) 2.0 V OK retour au menu modifier le paramètre Remarque : En l’absence de demande de chaleur, le PinTherm Connect va émettre 0Vdc. 5.15 Modifier le signal d’erreur maximal sélectionnez 0-10V max(5-10V) 0-10V max(5-10V) 10.0 V OK modifier le paramètre OK retour au menu 5.16 Modifier la plage de signal d’erreur sélectionnez 0-10V Range(1-3) OK 0-10V Range(1-3) 1.0 modifier le paramètre OK retour au menu Cette fonction permet de déterminé quand le signal 0-10 Vdc est modulé pendant la demande de chaleur. Quand ce dernier est réglé sur 1,0, le PinTherm Connect 1K va remoduler le signal 0-10 V en dessous de la température souhaitée. La plage est réglable de 0,5 -3,0 et est réglée d’usine sur 1,0. ­­­ 40 5.17 ModBus sélectionner MODBUS OK MODBUS INST. 001 modifier la valeur qui clignote OK revenir au menu FR aller au valeur suivant Slave ID : réglable 1-247 Paramètres par défaut: 1 5.18 Info Ethernet sélectionner INFO ETHERNET OK ADRESSE IP 192.168.001.100 OK ADRESSE MAC 5410EC220037 OK revenir au menu Affichage Adresse IP 5.19 Paramètres IP sélectionner ADRESSE IP OK MODE IP STATIQUE OK modifier le paramètre ADDRESS IP 192.168.001.100 MASK SUBNET 255.255.255.000 modifier la valeur qui clignote modifier la valeur qui clignote aller au valeur suivant aller au valeur suivant OK revenir au menu DHCP- affectation automatique Adresse IP Statique : Adresse IP fixe SUBnet Mask 5.20 Mettre en/hors service la minuterie supplémentaire Cette fonction permet, en dehors des délais de raccordement paramétrés, de faire passer manuellement 1, 2 ou 3 heures vers la température jour. La LED jaune avec le symbole va s’allumer quand cette fonction est enclenchée. Dans la partie inférieure droite de l’affichage, le temps restant, en minutes, sera affiché avant que la fonction se mette de nouveau hors service et que le PinTherm Connect fonctionne de nouveau sur la température nuit. Entre-temps, la fonction peut de nouveau être mise hors service en appuyant encore une fois sur le bouton poussoir jusqu’à ce que la LED jaune s’éteigne et que le nombre de 41 minutes ne s’affiche plus à l’écran. Voir l’illustration ci-dessous. LU 17:01 NUIT 18°C LU 17:01 18°C JOUR X:060 LU 17:01 18°C JOUR X:120 LU 17:01 18°C JOUR X:180 5.21 Mettre en service la fonction de ramonage de cheminée Cette fonction permet de faire chauffer l’appareil temporairement à pleine charge/charge partielle pour pouvoir effectuer des mesures, vous trouverez ci-dessous comment vous pouvez mettre en/ hors service cette fonction. Après la mise en service, cette fonction reste active pendant 15 minutes et sera ensuite automatiquement mise hors service. 0-10V 0 ±maintenir enfoncé pendant ±12 sec. 10V 14:59 Utilisez les boutons poussoirs ci-dessous pour faire fonctionner l’appareil à une tension inférieure (tension partielle). Appuyez pour augmenter la tension (max. 10 V) appuyez pour abaisser la tension De cette manière, vous mettez fin à la fonction ESC et vous revenez à l’écran principal. 5.22 Retour aux paramètres d’usine de PinTherm Connect Si vous appliquez cette fonction, tous les paramètres d’usine sont réinstallés. Cette fonction peut toujours être utilisée. Voir l’illustration ci-dessous. OK maintenez ce bouton enfoncé pendant environ 12 s. RETOUR EN REGLAGES USINE? OK REGLAGES USINE RESTAURES! SELECT LANGUAGE ENGLISH ESC cette opération vous permet de revenir à l'écran principal Les valeurs définies en usine ne seront pas modifiées! LU 08:01 JOUR 16°C 6.0 Destruction PinTherm Connect Quand le PinTherm Connect est remplacé ou éliminé, il convient de le faire recycler ou éliminer conformément aux règlements nationaux et/ou locaux. 7.0 Modbus - Communication [12] - Modbus-liste [13] 42 8.0 Possibilités de raccordement de PinTherm Connect PinTherm Connect 06.29.108 LU 08:01 JOUR FR 18ºC X:060 0 I RESET OK ESC L N Bornes de connexion (230Vac/50Hz) 21 - 22 Ventilation continue 21 - 23 Chauffage/climatisation 24 - 25 Lampe de panne 25 - 26 Réinitialisation contact + - 0-10Vdc (Chauffage/climatisation) 11 - 12 Capteur externe A - B MODBUS RTU (R ground) RJ 45 connector Internet / Modbus TCP/IP 13 - 14 Ventilateur externe de contact Avertissement: Présence d’une tension dangereuse sur N, L, 13, 14, 21, 22, 23, 24, 25 et 26 Avec le PinTherm Connect, seuls les dispositifs respectant les mesures de sécurité fixées dans EN-IEC 61010-1 peuvent être contrôlés. 43 Lees dit document door voordat u begint met de installatie en ingebruikname Waarschuwing! Een foutief uitgevoerde installatie, wijziging of reparatie kan leiden tot materiële schade of verwondingen. Alle werkzaamheden moeten door erkende, gekwalificeerde vakmensen worden uitgevoerd. Indien het toestel niet volgens voorschrift wordt geplaatst, vervalt de garantie. Dit apparaat is niet bedoeld voor gebruik door personen (inclusief kinderen) met verminderde lichamelijke, zintuiglijke of geestelijke vermogens, of gebrek aan ervaring en kennis, tenzij zij onder toezicht staan of worden geïnstrueerd over het gebruik van het apparaat door een persoon die verantwoordelijk is voor hun veiligheid. Kinderen moeten gecontroleerd worden om ervoor te zorgen dat ze niet met het apparaat spelen. 44 1.0 Inhoudsopgave 2.0 Algemeen 2.1 Wijzigingen voorbehouden 2.2 Algemene waarschuwingen pag. pag. 46 46 3.0 Technische gegevens 3.1 Technische gegevens PinTherm Connect 3.2 Technische gegevens externe ruimtesensor (optioneel) 3.3 Weerstandstabel externe ruimtesensor (optioneel) 3.4 Fabrieksinstellingen PinTherm Connect pag. pag. pag. pag. 46 47 47 47 4.0 Installatie 4.1 Algemeen 4.2 Montage PinTherm Connect 4.3 Montage externe ruimtesensor pag. pag. pag. 48 48 48 5.0 Bedieningshandleiding 5.1 Verklaring drukknoppen en led`s 5.2 Verklaring display 5.3 Eerste ingebruikname van de PinTherm Connect 5.4 Activeren van het gebruikersmenu 5.5 Schakeltijden ingeven of wijzigen 5.6 Dag-/nachttemperatuur wijzigen 5.7 Tijd en datum wijzigen 5.8 Vakantieregeling instellen 5.9 Menu code wijzigen 5.10 Taalkeuze wijzigen 5.11 IJking 5.12 Verwarmen/koelen 5.13 Schakeldifferentie 5.14 Minimum regelsignaal wijzigen 5.15 Maximum regelsignaal wijzigen 5.16 Range regelsignaal wijzigen 5.17 ModBus 5.18 Ethernet Info 5.19 IP-instellingen 5.20 Overwerktimer in- /uitschakelen 5.21 Schoorsteenvegerfunctie inschakelen 5.22 Terugplaatsen fabrieksinstellingen PinTherm Connect pag. pag. pag. pag. pag. pag. pag. pag. pag. pag. pag. pag. pag. pag. pag. pag. pag. pag. pag. pag. pag. pag. 49 50 50 51 51 52 52 52 52 53 53 53 54 54 54 54 55 55 55 55 56 56 6.0 Afdanken PinTherm Connect pag. 56 7.0 Modbus pag. 56 8.0 Aansluitmogelijkheden PinTherm Connect pag. 57 Bijlage I Aansluitschema’s Bijlage II Modbus pag. pag. 87 94 NL 45 2.0 Algemeen 2.1 Wijzigingen voorbehouden De fabrikant streeft continu naar verbetering van haar producten en behoudt zich het recht voor om zonder voorafgaande kennisgeving veranderingen in de specificaties aan te brengen. De technische details worden als correct verondersteld maar vormen geen basis voor een contract of garantie. Alle orders worden geaccepteerd onder de standaard condities van onze algemene verkoop- en leveringsvoorwaarden (op aanvraag leverbaar). 2.2 Algemene waarschuwingen De installatie moet voldoen aan de geldende plaatselijke en/of landelijke voorschriften. Laat daarom de PinTherm Connect door een vakbekwaam en gekwalificeerd installateur installeren met inachtneming van de nationale en internationale regelgeving. Bij een foutieve installatie, afregeling, wijziging, onderhoudsafhandeling of herstelling vervalt de garantie. Schakel altijd de 230V voeding uit voordat er aan de terminals/aansluitklemmen geschroefd wordt. De netspanning op de PinTherm Connect moet dubbelpolig uitschakelbaar zijn middels een permanent aanwezige schakelaar welke geschikt is voor 250VAC/10A en voldoet aan de geldende veiligheidsvoorschriften. Met de PinTherm Connect mogen alleen toestellen aangestuurd worden die voldoen aan EN-IEC 61010-1. Reinig de behuizing van de PinTherm Connect met een vochtige doek. Geen oplosmiddelen toepassen. Er zijn geen eisen met betrekking tot de ventilatie in de directe omgeving van de regelaar. Waarschuwing - risico op elektrische schok. ! Waarschuwing - algemeen waarschuwing, kans op gevaar. Op de aansluitklemmen waarbij een ! is geplaats kan netspanning staan. 3.0 Technisch gegevens 3.1 Technische gegevens PinTherm Connect • Type aanduiding : PinTherm Connect • Artikelnummer : 06 29 108 • Voeding PinTherm Connect : 90 – 240 VAC / 47-63Hz • Eigen verbruik : < 9W • Klok : 24uurs klok met automatische zomer/wintertijd omschakeling • Schakelprogramma’s : 3 schakelprogramma’s per dag • Schakeldifferentie : 0,1 - 3K • Afmeting : 166 x 160 x 106mm (lxbxh) • Gewicht : 880 gram • Beschermingsgraad : IP-54 • Installatie omgeving : Transport/opslag: -20°C tot +70°C. Operationeel: -10°C tot +60°C Relatieve luchtvochtigheid: 0-90% niet condenserend Installatie maximaal 2000 meter boven zeeniveau. • Overspanningscategorie : 11 • Pollutiegraad : 2 46 • Schakelcontact(en)* : • Temperatuurinstelling : • Overwerktimer : • IJking : • Verwarmen/koelen : • 0-10 VDC : • Sensor : • Instelbare talen : • Voorzekering : Verwarmen: 230Vac/16A (4A) Overige: 230Vac/10A (2,5A) 0 tot 39°C per 1°C instelbaar instelbaar 1, 2 of 3 uur (060, 120, 180) instelbaar van -3.5°C tot +3.5°C Omkeerbaar contact t.b.v. verwarmen of koelen 0-10 VDC output t.b.v. verwarmen of koelen externe ruimtesensor (06 29 086) NL/EN/DE/FR/PL/RO/LT 6A NL * De relais contacten zijn functionele schakelaars, geen veiligheidsschakelaars. 3.2 Technische gegevens externe ruimtesensor (optioneel) • Type aanduiding : RSTF NTC4,7K • Artikelnummer : 06 29 086 • Weerstand : NTC 4K7 • Afmeting : 79 x 81 x 26mm (lxbxh) • Gewicht : 46 gram • Elektrische aansluiting : 0.75 -1.5mm² • Beschermingsgraad : IP-30 3.3 Weerstandstabel externe ruimtesensor (optioneel) -15°C -10°C -5°C 32.937kโ„ฆ 25.217kโ„ฆ 19.392kโ„ฆ 0°C 15.040kโ„ฆ 5°C 11.743kโ„ฆ 10°C 9.241kโ„ฆ 15°C 7.330kโ„ฆ 20°C 5.855kโ„ฆ 35°C 3.071kโ„ฆ 40°C 2.512kโ„ฆ 45°C 2.066kโ„ฆ 50°C 1.709kโ„ฆ 25°C 4.700kโ„ฆ 30°C 3.777kโ„ฆ 3.4 Fabrieksinstellingen PinTherm Connect • Menu code : 1000 • Schakeltijden : MA, DI, WO, DO, VR 07:30-17:30 uur ZA, ZO 00:00-00:00 uur • Ruimtetemperatuur : Dagtemperatuur 18°C Nachttemperatuur 08°C • IJking : +0.0 • Schakeldifferentie : 1K • Verwarmen/koelen : Verwarmen • 0-10V range : 1K • 0-10V min : 0V • 0-10V max : 10V • Modbus : Slave ID 001 • IP-instelling : statisch 47 4.0 Installatie 4.1 Algemeen Controleer na het uitpakken de PinTherm Connect en meegeleverde externe voeler op beschadiging. Controleer op juistheid van het type/model en de elektrische spanning. 4.2 Montage PinTherm Connect Bepaal een geschikte plaats om de PinTherm Connect te monteren. Bevestig de PinTherm Connect op een stevige ondergrond, die minimaal 4kg kan dragen. Geadviseerd wordt om de PinTherm Connect op een afstand van ±1.5m vanaf de vloer te plaatsen, op een goed bereikbare plaats. Pas ten behoeve van de kabeldoorvoer kabelwartels toe voorzien van trekontlasting, met een minimale brandklasse van UL94V2. Controleer voor het aansluiten van de bekabeling of de spanning is uitgeschakeld. Indien dit niet het geval is dient eerst de spanning te worden uitgeschakeld voordat u verder gaat. Bij het uitschakelen van de spanning, van het aan te sluiten toestel, dient hierbij ook het technisch boek/bedieningshandleiding van het toestel in acht te worden genomen. Sluit de PinTherm Connect aan volgens een van de meegeleverde elektrische schema’s welke achterin dit technisch boek staan. Om het juiste aansluitschema te selecteren moet u weten op welk type toestel u de PinTherm Connect gaat aansluiten. Voor een selectie zie ook bijlage I. Bij het toepassen van een 0-10VDC signaal, zie de tabel hieronder voor de juiste kabeldiameter en bijbehorende lengte. Diameter 0.8mm2 1.0mm2 1.5mm2 Lengte 80 meter 100 meter 150 meter Geadviseerd wordt om hiervoor een afgeschermde kabel te gebruiken 4.3 Montage externe ruimtesensor Plaats de externe ruimtesensor tochtvrij, in het zicht van het toestel op een hoogte van ca. 1.5m vanaf de vloer. En sluit de voeler aan op de daarvoor bestemde klemmen in de PinTherm Connect. Zie onderstaande tabel voor de juiste kabeldiameter. Diameter 0.8mm2 1.0mm2 1.5mm2 48 Lengte 80 meter 100 meter 150 meter Geadviseerd wordt om hiervoor een afgeschermde kabel te gebruiken. 5.0 Bedieningshandleiding 5.1 Verklaring drukknoppen en led`s. A PinTherm Connect NL 06.29.108 MA 08:01 18ºC DAG X:060 H B D F C 0 E I G M RESET I A B C D E F G H I J K L M N O - OK N ESC O J K L Verlichte display (zie ook 5.2) Drukknop om de stand verwarmen in of uit te schakelen. Led licht op als de functie verwarmen is ingeschakeld. Drukknop om het continue draaien van de ventilator in of uit te schakelen. Led licht op als de functie continue ventileren is ingeschakeld. Drukknop om in geval van een (brander)storing het toestel te ontgrendelen. Led brand in geval van (brander)storing. Drukknop om het gebruikersmenu te activeren of om naar het volgende cijfer te gaan. Drukknop om een gemaakte keuze/wijziging te bevestigen of om naar het volgende menu item te gaan. Drukknop om het menu of de instelling te verlaten zonder een wijziging uit te voeren. Drukknop om de overwerktimer in of uit te schakelen. Drukknop ๏€ต+๏€ถ­– om een instelling te wijzigen. Led licht op bij warmtevraag in de stand verwarmen (brander in). Led licht op wanneer de ventilator continue draait. Led licht op als de functie overwerktimer is ingeschakeld. 49 5.2 Verklaring display B A MO C 08:01 18ºC DAY X:060 D E A B C D E Geeft de dag van de week weer. De actuele kloktijd wordt hier weergegeven. Geeft de gemeten temperatuur (°C) aan. Geeft het aantal minuten aan voordat de functie overwerktimer weer wordt uitgeschakeld en de PinTherm Connect weer op de nachttemperatuur gaat regelen. Geeft aan of de PinTherm Connect in de dagstand (DAG) of in de nachtstand (NACHT) staat en regelt op basis van de dag- of nachttemperatuur. 5.3 Eerste ingebruikname van de PinTherm Connect Wanneer u voor de eerste keer spanning op de PinTherm Connect zet zal u worden gevraagd om ๏€‚ ๏€„ ๏€… ๏€† ๏€‡ ๏€‰ ๏€‚๏€ de ๏€gewenste taal te๏€ƒselecteren, (instelbare talen: NL, EN, DE, ๏€ˆFR, PL, RO, LT), ๏€Šen vervolgens de๏€‚๏€‚ tijd en datum in te stellen. Hierna keert de PinTherm Connect terug naar het hoofdscherm. ๏€๏€๏€‘๏€๏€Ž๏€’๏€Œ๏€‘๏€‚๏€“๏€„๏€”๏€‚๏€„๏€ ๏€๏€“๏€„๏€‘๏€˜๏€๏€™ ๏€๏€‚ ๏€•๏€‚ ๏€…๏€ˆ๏€–๏€…๏€ˆ๏€–๏€—๏€…๏€…๏€‹ ๏€…๏€…๏€‡๏€…๏€…๏€‡๏€…๏€… ๏€ฆ๏€œ๏€บ๏€œ๏€ฅ๏€ณ๏€๏€œ๏€’๏€๏€ซ๏€ซ๏€ข ๏€ณ๏€œ๏€ข๏€œ๏€Ÿ๏€๏€œ๏€ฉ๏€œ๏€ฅ ๏€บ๏€ค๏€ป๏€ผ๏€ค๏€ฆ๏€๏€’๏€จ๏€œ๏€ ๏€ต๏€ฅ๏€ค๏€ฐ๏€ฐ๏€œ๏€ฉ๏€œ๏€ฅ๏€ฃ๏€œ๏€’๏€Ÿ๏€ค๏€ป๏€ ๏€œ๏€ฉ ๏€ฅ๏€ซ๏€ซ๏€ฉ๏€’๏€จ๏€œ๏€๏€’๏€ฝ๏€ฎ๏€ข๏€ฆ๏€œ๏€ฅ๏€ฃ๏€œ ๏€Ÿ๏€ค๏€ป๏€ ๏€œ๏€ฉ๏€’๏€ฆ๏€ซ๏€ซ๏€ฅ ๏€๏€‚ Instelbare talen: NL, EN, DE, FR, PL, RO, LT 50 ๏€…๏€†๏€‡๏€…๏€… ๏€ƒ๏€‚๏€„ ๏€Œ๏€ˆ๏€‹ ๏€Œ๏€๏€Ž ๏€๏€‚ ๏€‚๏€ƒ ๏€‚๏€„ ๏€ ๏€‚ ๏€ƒ ๏€„ ๏€… ๏€† ๏€‡ ๏€ˆ ๏€‰ ๏€Š ๏€‚๏€ ๏€‚๏€‚ ๏€‚๏€ƒ ๏€‚๏€„ 5.4 Activeren van het gebruikersmenu ๏€๏€‚ ๏€…๏€†๏€‡๏€…๏€ˆ ๏€ƒ๏€‚๏€„ ๏€Œ๏€ˆ๏€‹ ๏€Œ๏€๏€Ž ๏€š๏€›๏€๏€œ๏€Œ๏€Ž๏€›๏€ƒ๏€๏€Œ๏€˜๏€“ ๏€…๏€…๏€…๏€… ๏€๏€‚ ๏€๏€‚ ๏€บ๏€ค๏€ป๏€ผ๏€ค๏€ฆ๏€๏€’๏€จ๏€œ๏€ ๏€ต๏€ฅ๏€ค๏€ฐ๏€ฐ๏€œ๏€ฉ๏€œ๏€ฅ๏€ฃ๏€œ๏€’๏€Ÿ๏€ค๏€ป๏€ ๏€œ๏€ฉ ๏€Š๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€Ž๏€’๏€‘๏€“๏€๏€”๏€”๏€Ž๏€’๏€• ๏€–๏€๏€’๏€—๏€˜๏€™๏€š๏€›๏€ ๏€œ๏€ˆ๏€ˆ๏€ˆ ๏€ฅ๏€ซ๏€ซ๏€ฉ๏€’๏€จ๏€œ๏€๏€’๏€ฝ๏€ฎ๏€ข๏€ฆ๏€œ๏€ฅ๏€ฃ๏€œ ๏€Ÿ๏€ค๏€ป๏€ ๏€œ๏€ฉ๏€’๏€ฆ๏€ซ๏€ซ๏€ฅ NL ๏€๏€Ž๏€™๏€‚๏€‰๏€๏€‘๏€’๏€˜๏€๏€ƒ๏€๏€“ ๏€˜๏€“๏€„๏€๏€š๏€๏€“๏€ž๏€Ÿ๏€˜๏€๏€•๏€˜๏€„๏€๏€“ ๏€ช๏€ซ๏€ซ๏€ต๏€’๏€ฃ๏€œ๏€’๏€ฆ๏€œ๏€บ๏€œ๏€ฅ๏€ณ๏€๏€œ ๏€ช๏€œ๏€ฅ๏€ญ๏€ต๏€œ๏€ญ๏€ผ๏€œ ๏€„๏€…๏€‡ ๏€ฝ๏€œ๏€ฉ๏€ข๏€ซ๏€ซ๏€๏€’๏€จ๏€œ๏€๏€’๏€ช๏€œ๏€ฅ๏€ญ๏€’๏€œ๏€ฅ๏€’๏€ต๏€œ๏€œ๏€ฉ ๏€๏€œ๏€ฉ๏€ญ๏€ฆ๏€’๏€ฅ๏€ซ๏€ซ๏€ฉ๏€’๏€จ๏€œ๏€๏€’๏€จ๏€ฎ๏€ฎ๏€ ๏€ฃ๏€ณ๏€Ÿ๏€จ๏€œ๏€ฉ๏€ช In het menu kunt u de volgende instellingen wijzigen: – Schakeltijden ingeven/wijzigen – Dag-/Nachttemperatuur wijzigen – Tijd/datum wijzigen – Vakantieregeling – Menu code wijzigen – Taalkeuze wijzigen – IJking – 0-10V min 0-5V – 0-10V max 5-10V – 0-10V range (1-3) – Modbus – IP-instelling ๏€ ๏€‚ 5.5 Schakeltijden ingeven of wijzigen ๏€ƒ ๏€„ ๏€… ๏€† ๏€๏€Ž๏€™๏€‚๏€‰๏€๏€‘๏€’๏€˜๏€๏€ƒ๏€๏€“ ๏€˜๏€“๏€„๏€๏€š๏€๏€“๏€ž๏€Ÿ๏€˜๏€๏€•๏€˜๏€„๏€๏€“ ๏€‡ ๏€๏€‚ ๏€ต๏€’๏€’๏€ข๏€’๏€’๏€ค๏€’๏€’๏€ช๏€’๏€’๏€ซ๏€’๏€’๏€ซ๏€’๏€’๏€๏€’๏€’๏€๏€’๏€’๏€œ๏€’๏€’๏€Ÿ๏€’๏€’๏€จ๏€’๏€’๏€ฅ๏€’๏€’๏€ค๏€’๏€’๏€œ๏€’๏€’๏€ต ๏€บ๏€ค๏€ป๏€ผ๏€ค๏€ฆ๏€๏€’๏€จ๏€œ๏€ ๏€ต๏€ฅ๏€ค๏€ฐ๏€ฐ๏€œ๏€ฉ๏€œ๏€ฅ๏€ฃ๏€œ๏€’๏€Ÿ๏€ค๏€ป๏€ ๏€œ๏€ฉ ๏€‰ ๏€๏€‚๏€‚๏€“๏€ƒ๏€‚๏€„ ๏€ˆ ๏€…๏€ ๏€‡๏€ก๏€…๏€Œ๏€–๏€ข๏€ˆ๏€ ๏€‡๏€…๏€… ๏€บ๏€ค๏€ป๏€ผ๏€ค๏€ฆ๏€๏€’๏€จ๏€œ๏€ ๏€ต๏€ฅ๏€ค๏€ฐ๏€ฐ๏€œ๏€ฉ๏€œ๏€ฅ๏€ฃ๏€œ๏€’๏€Ÿ๏€ค๏€ป๏€ ๏€œ๏€ฉ ๏€ ๏€๏€‚๏€‚๏€“๏€ƒ๏€‚๏€„ ๏€ก ๏€–๏€–๏€‡๏€–๏€–๏€Œ๏€–๏€ข๏€–๏€–๏€‡๏€–๏€– ๏€ˆ ๏€Š ๏€‚๏€ ๏€๏€‚ ๏€‚๏€‚ ๏€‚๏€ƒ ๏€๏€‚๏€‚๏€“๏€ƒ๏€‚๏€„ ๏€— ๏€–๏€–๏€‡๏€–๏€–๏€Œ๏€–๏€ข๏€–๏€–๏€‡๏€–๏€– ๏€‚๏€„ ๏€‚๏€… ๏€‚๏€† ๏€ƒ๏€˜๏€“๏€๏€ƒ๏€‚๏€„ ๏€ˆ ๏€…๏€ ๏€‡๏€ก๏€…๏€Œ๏€–๏€ข๏€ˆ๏€ ๏€‡๏€…๏€… ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€๏€‘๏€Ž๏€”๏€•๏€๏€Ž๏€–๏€•๏€Ž๏€Ž๏€ ๏€—๏€Œ๏€‘๏€•๏€˜๏€๏€๏€“๏€’๏€‘๏€๏€™๏€๏€๏€š๏€›๏€‘๏€™๏€” ๏€œ๏€ฅ๏€ผ๏€ž๏€ž๏€ž ๏€•๏€›๏€“๏€ƒ๏€‚๏€„ ๏€ก ๏€–๏€–๏€‡๏€–๏€–๏€Œ๏€–๏€ข๏€–๏€–๏€‡๏€–๏€– ๏€‚๏€ˆ ๏€๏€‚ ๏€›๏€ ๏€ก๏€œ๏€œ๏€ข๏€ฃ๏€ค๏€ฅ๏€ฆ๏€’๏€ณ๏€Ÿ๏€จ๏€œ๏€ฉ๏€ช๏€’๏€๏€‡๏€ƒ๏€Š๏€๏€Š๏€ƒ ๏€๏€œ๏€๏€ž ๏€๏€œ๏€Ÿ๏€ž ๏€ฅ๏€ซ๏€ซ๏€ฉ๏€’๏€จ๏€œ๏€๏€’๏€ฝ๏€ฎ๏€ข๏€ฆ๏€œ๏€ฅ๏€ฃ๏€œ ๏€Ÿ๏€ค๏€ป๏€ ๏€œ๏€ฉ๏€’๏€ฆ๏€ซ๏€ซ๏€ฅ ๏€๏€‚ ๏€‚๏€‡ ๏€๏€‚ ๏€๏€œ๏€ฉ๏€ญ๏€ฆ๏€’๏€ฅ๏€ซ๏€ซ๏€ฉ ๏€จ๏€œ๏€๏€’๏€ช๏€œ๏€ฅ๏€ญ ๏€ฅ๏€ซ๏€ซ๏€ฉ๏€’๏€จ๏€œ๏€๏€’๏€ฝ๏€ฎ๏€ข๏€ฆ๏€œ๏€ฅ๏€ฃ๏€œ ๏€Ÿ๏€ค๏€ป๏€ ๏€œ๏€ฉ๏€’๏€ฆ๏€ซ๏€ซ๏€ฅ 51 ๏€™๏€ซ๏€๏€ญ ๏€‘๏€ฎ๏€ฉ๏€ช ๏€ ๏€‚ ๏€ƒ ๏€„ ๏€… ๏€† ๏€‡ ๏€ˆ ๏€‰ ๏€Š ๏€‚๏€ ๏€‚๏€‚ ๏€‚๏€ƒ ๏€‚๏€„ ๏€‚๏€… ๏€‚๏€† 5.6 Dag-/nachttemperatuur wijzigen ๏€ณ๏€œ๏€ข๏€œ๏€Ÿ๏€๏€œ๏€œ๏€ฉ ๏€„๏€๏€Ÿ๏€๏€“๏€๏€’๏€ ๏€’๏€๏€๏€ฃ๏€๏€œ๏€‚๏€’๏€”๏€”๏€œ ๏€ƒ๏€‚๏€„๏€’๏€๏€๏€ฃ๏€๏€œ๏€‚๏€’๏€”๏€”๏€œ ๏€ˆ๏€†๏€๏€Ž ๏€๏€‚ ๏€๏€‚ ๏€บ๏€ค๏€ป๏€ผ๏€ค๏€ฆ๏€๏€’๏€จ๏€œ๏€ ๏€ต๏€ฅ๏€ค๏€ฐ๏€ฐ๏€œ๏€ฉ๏€œ๏€ฅ๏€ฃ๏€œ๏€’๏€Ÿ๏€ค๏€ป๏€ ๏€œ๏€ฉ ๏€ฅ๏€ซ๏€ซ๏€ฉ๏€’๏€จ๏€œ๏€๏€’๏€ฝ๏€ฎ๏€ข๏€ฆ๏€œ๏€ฅ๏€ฃ๏€œ ๏€Ÿ๏€ค๏€ป๏€ ๏€œ๏€ฉ๏€’๏€ฆ๏€ซ๏€ซ๏€ฅ ๏€“๏€‚๏€Ž๏€™๏€’๏€’๏€๏€๏€ฃ๏€๏€œ๏€‚๏€’๏€”๏€”๏€œ ๏€…๏€†๏€๏€Ž ๏€๏€‚ ๏€๏€œ๏€ฉ๏€ญ๏€ฆ๏€’๏€ฅ๏€ซ๏€ซ๏€ฉ ๏€จ๏€œ๏€๏€’๏€ช๏€œ๏€ฅ๏€ญ ๏€บ๏€ค๏€ป๏€ผ๏€ค๏€ฆ๏€๏€’๏€จ๏€œ๏€ ๏€ต๏€ฅ๏€ค๏€ฐ๏€ฐ๏€œ๏€ฉ๏€œ๏€ฅ๏€ฃ๏€œ๏€’๏€Ÿ๏€ค๏€ป๏€ ๏€œ๏€ฉ ๏€ฅ๏€ซ๏€ซ๏€ฉ๏€’๏€จ๏€œ๏€๏€’๏€ฝ๏€ฎ๏€ข๏€ฆ๏€œ๏€ฅ๏€ฃ๏€œ ๏€Ÿ๏€ค๏€ป๏€ ๏€œ๏€ฉ๏€’๏€ฆ๏€ซ๏€ซ๏€ฅ ๏€ ๏€‚ ๏€ƒ ๏€„ ๏€… ๏€† ๏€‡ ๏€ˆ ๏€‰ ๏€Š ๏€‚๏€ ๏€‚๏€‚ ๏€‚๏€ƒ ๏€‚๏€„ ๏€‚๏€… ๏€‚ 5.7 Tijd en datum wijzigen ๏€ณ๏€œ๏€ข๏€œ๏€Ÿ๏€๏€œ๏€œ๏€ฉ ๏€’๏€˜๏€๏€ƒ๏€ž๏€ƒ๏€‚๏€’๏€”๏€ ๏€Ÿ๏€˜๏€๏€•๏€˜๏€„๏€๏€“ ๏€๏€‚ ๏€—๏€ก๏€–๏€…๏€ก๏€–๏€—๏€…๏€…๏€ค ๏€…๏€ค๏€‡๏€ˆ๏€…๏€‡๏€…๏€… ๏€๏€‚ ๏€๏€‚ ๏€๏€œ๏€ฉ๏€ญ๏€ฆ๏€’๏€ฅ๏€ซ๏€ซ๏€ฉ ๏€จ๏€œ๏€๏€’๏€ช๏€œ๏€ฅ๏€ญ ๏€บ๏€ค๏€ป๏€ผ๏€ค๏€ฆ๏€๏€’๏€จ๏€œ๏€ ๏€ต๏€ฅ๏€ค๏€ฐ๏€ฐ๏€œ๏€ฉ๏€œ๏€ฅ๏€ฃ๏€œ๏€’๏€Ÿ๏€ค๏€ป๏€ ๏€œ๏€ฉ ๏€ฅ๏€ซ๏€ซ๏€ฉ๏€’๏€จ๏€œ๏€๏€’๏€ฝ๏€ฎ๏€ข๏€ฆ๏€œ๏€ฅ๏€ฃ๏€œ ๏€Ÿ๏€ค๏€ป๏€ ๏€œ๏€ฉ๏€’๏€ฆ๏€ซ๏€ซ๏€ฅ 5.8 Vakantieregeling instellen VAKANTIEREG. ACT select VAKANTIEREG. ACT AAN OK OK VAN: 01-07-2017 TOT: 01-08-2017 aan of uit selecteren OK terug naar het menu wijzigt het knipperende cijfer naar het volgende cijfer gaan ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€๏€‘๏€Ž๏€”๏€•๏€๏€Ž๏€–๏€•๏€Ž๏€Ž๏€ ๏€—๏€Œ๏€‘๏€•๏€˜๏€๏€๏€“๏€’๏€‘๏€๏€™๏€๏€๏€š๏€›๏€‘๏€™๏€” ๏€ ๏€™๏€ซ๏€๏€ญ๏€ช ๏€‘๏€ฎ๏€ฉ๏€ช Gedurende het ingestelde tijdsblok, zal de regeling regelen volgens de nachttemperatuur. ๏€ต๏€’๏€’๏€ข๏€’๏€’๏€ค๏€’๏€’๏€ช๏€’๏€’๏€ซ๏€’๏€’๏€ซ๏€’๏€’๏€๏€’๏€’๏€๏€’๏€’๏€œ๏€’๏€’๏€Ÿ๏€’๏€’๏€จ๏€’๏€’๏€ฅ๏€’๏€’๏€ค๏€’๏€’๏€œ๏€’๏€’๏€ต ๏€ ๏€‚ ๏€ƒ ๏€„ ๏€… ๏€† ๏€‡ ๏€ˆ ๏€‰ ๏€Š ๏€” ๏€ฅ ๏€›๏€ ๏€ก๏€œ๏€œ๏€ข๏€ฃ๏€ค๏€ฅ๏€ฆ๏€’๏€ณ๏€Ÿ๏€จ๏€œ๏€ฉ๏€ช๏€’๏€๏€‡๏€ƒ๏€Š๏€๏€Š๏€ƒ ๏€๏€œ๏€๏€ž ๏€๏€œ๏€Ÿ๏€ž ๏€‚๏€ ๏€‚๏€‚ ๏€‚๏€ƒ ๏€‚๏€„ ๏€„๏€ฏ๏€‚๏€‚๏€ฏ๏€ƒ๏€๏€‚๏€‡ ๏€‚๏€… 5.9 Menu code wijzigen ๏€ณ๏€œ๏€ข๏€œ๏€Ÿ๏€๏€œ๏€œ๏€ฉ ๏€๏€๏€“๏€”๏€Œ๏€Ž๏€›๏€ƒ๏€ ๏€Ÿ๏€˜๏€๏€•๏€˜๏€„๏€๏€“ ๏€๏€‚ ๏€‰๏€˜๏€๏€๏€Œ๏€“๏€˜๏€๏€”๏€Ÿ๏€๏€Œ๏€Ž๏€›๏€ƒ๏€ ๏€ˆ๏€…๏€…๏€… ๏€บ๏€ค๏€ป๏€ผ๏€ค๏€ฆ๏€๏€’๏€จ๏€œ๏€ ๏€ต๏€ฅ๏€ค๏€ฐ๏€ฐ๏€œ๏€ฉ๏€œ๏€ฅ๏€ฃ๏€œ๏€’๏€Ÿ๏€ค๏€ป๏€ ๏€œ๏€ฉ ๏€๏€‚ ๏€๏€œ๏€ฉ๏€ญ๏€ฆ๏€’๏€ฅ๏€ซ๏€ซ๏€ฉ ๏€จ๏€œ๏€๏€’๏€ช๏€œ๏€ฅ๏€ญ ๏€ฅ๏€ซ๏€ซ๏€ฉ๏€’๏€จ๏€œ๏€๏€’๏€ฝ๏€ฎ๏€ข๏€ฆ๏€œ๏€ฅ๏€ฃ๏€œ ๏€Ÿ๏€ค๏€ป๏€ ๏€œ๏€ฉ๏€’๏€ฆ๏€ซ๏€ซ๏€ฅ ๏€๏€Ž๏€๏€—๏€ž๏€๏€˜๏€–๏€๏€’๏€—๏€˜๏€™๏€š๏€›๏€ 52 ๏€ ๏€ต๏€’๏€’๏€ข๏€’๏€’๏€ค๏€’๏€’๏€ช๏€’๏€’๏€ซ๏€’๏€’๏€ซ๏€’๏€’๏€๏€’๏€’๏€๏€’๏€’๏€œ๏€’๏€’๏€Ÿ๏€’๏€’๏€จ๏€’๏€’๏€ฅ๏€’๏€’๏€ค๏€’๏€’๏€œ๏€’๏€’๏€ต ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€๏€‘๏€Ž๏€”๏€•๏€๏€Ž๏€–๏€•๏€Ž๏€Ž๏€ ๏€—๏€Œ๏€‘๏€•๏€˜๏€๏€๏€“๏€’๏€‘๏€๏€™๏€๏€๏€š๏€›๏€‘๏€™๏€” ๏€›๏€ ๏€ก๏€œ๏€œ๏€ข๏€ฃ๏€ค๏€ฅ๏€ฆ๏€’๏€ณ๏€Ÿ๏€จ๏€œ๏€ฉ๏€ช๏€’๏€๏€‡๏€ƒ๏€Š๏€๏€Š๏€ƒ ๏€๏€œ๏€๏€ž ๏€๏€œ๏€Ÿ๏€ž ๏€™๏€ซ๏€๏€ญ๏€ช ๏€‘๏€ฎ๏€ฉ๏€ช ๏€„๏€ฏ๏€‚๏€‚๏€ฏ๏€ƒ๏€๏€‚๏€‡ ๏€ ๏€› ๏€‚๏€† ๏€ ๏€‚ ๏€ƒ ๏€„ ๏€… ๏€† ๏€‡ ๏€ˆ ๏€‰ ๏€Š ๏€‚๏€ ๏€‚๏€‚ ๏€‚๏€ƒ ๏€‚๏€„ ๏€‚๏€… ๏€‚๏€† ๏€‚๏€… ๏€‚๏€† 5.10 Taalkeuze wijzigen ๏€ณ๏€œ๏€ข๏€œ๏€Ÿ๏€๏€œ๏€œ๏€ฉ ๏€’๏€‚๏€‚๏€‘๏€‰๏€๏€”๏€•๏€ ๏€Ÿ๏€˜๏€๏€•๏€˜๏€„๏€๏€“ ๏€๏€‚ ๏€’๏€‚๏€‚๏€‘๏€‰๏€๏€”๏€•๏€ ๏€“๏€๏€ƒ๏€๏€œ๏€‘๏€‚๏€“๏€ƒ๏€ ๏€ฆ๏€œ๏€บ๏€œ๏€ฅ๏€ณ๏€๏€œ๏€’๏€๏€ซ๏€ซ๏€ข ๏€ณ๏€œ๏€ข๏€œ๏€Ÿ๏€๏€œ๏€ฉ๏€œ๏€ฅ ๏€๏€‚ ๏€๏€œ๏€ฉ๏€ญ๏€ฆ๏€’๏€ฅ๏€ซ๏€ซ๏€ฉ ๏€จ๏€œ๏€๏€’๏€ช๏€œ๏€ฅ๏€ญ NL Instelbare talen: NL, EN, DE, FR, PL, RO, LT. 5.11 IJking In geval van een ongunstige montageplaats van de externe voeler, kan er een afwijking optreden van de werkelijk gemeten temperatuur door de PinTherm Connect. Dit temperatuurverschil kan met deze ijkingfunctie worden gecompenseerd door het instellen van een correctiewaarde. ๏€ Voorbeeld: ๏€‚ ๏€ƒ ๏€ณ๏€œ๏€ข๏€œ๏€Ÿ๏€๏€œ๏€œ๏€ฉ De gemeten temperatuur bedraagt 18°C, het beeldscherm op de PinTherm Connect aan.๏€‡ Het verschil bedraagt in dit voorbeeld ๏€„ ๏€… geeft 20°C ๏€† ๏€ˆ ๏€‰ ๏€Š ๏€‚๏€ ๏€‚๏€‚dus 2°C ๏€‚๏€ƒ te hoog de correctiewaarde moet dan ingesteld worden op -2°C. ๏€˜๏€๏€‰๏€˜๏€“๏€„ ๏€‚๏€„ ๏€˜๏€๏€‰๏€˜๏€“๏€„ ๏€๏€‚ ๏€ฅ๏€Œ๏€…๏€ฆ๏€…๏€๏€Ž ๏€บ๏€ค๏€ป๏€ผ๏€ค๏€ฆ๏€๏€’๏€จ๏€œ๏€ ๏€ต๏€ฅ๏€ค๏€ฐ๏€ฐ๏€œ๏€ฉ๏€œ๏€ฅ๏€ฃ๏€œ๏€’๏€Ÿ๏€ค๏€ป๏€ ๏€œ๏€ฉ ๏€๏€‚ ๏€๏€œ๏€ฉ๏€ญ๏€ฆ๏€’๏€ฅ๏€ซ๏€ซ๏€ฉ ๏€จ๏€œ๏€๏€’๏€ช๏€œ๏€ฅ๏€ญ ๏€ฅ๏€ซ๏€ซ๏€ฉ๏€’๏€จ๏€œ๏€๏€’๏€ฝ๏€ฎ๏€ข๏€ฆ๏€œ๏€ฅ๏€ฃ๏€œ ๏€Ÿ๏€ค๏€ป๏€ ๏€œ๏€ฉ๏€’๏€ฆ๏€ซ๏€ซ๏€ฅ ๏€‡๏€š๏€๏€๏€๏€™๏€“๏€Ž๏€๏€ž๏€‹๏€‹๏€๏€›๏€๏€˜๏€Ž๏€‘๏€˜๏€Ž๏€’๏€‘๏€“๏€๏€”๏€Œ๏€‹๏€‹๏€ ๏€Ÿ๏€‹๏€’๏€˜๏€ ๏€ก๏€ข๏€ฃ๏€ค๏€‡๏€˜๏€“๏€š๏€“๏€˜๏€ฅ๏€ก๏€ข๏€ฃ๏€ค๏€‡ 5.12 Verwarmen/koelen selecteer ๏€ ๏€ต๏€’๏€’๏€ข๏€’๏€’๏€ค๏€’๏€’๏€ช๏€’๏€’๏€ซ๏€’๏€’๏€ซ๏€’๏€’๏€๏€’๏€’๏€๏€’๏€’๏€œ๏€’๏€’๏€Ÿ๏€’๏€’๏€จ๏€’๏€’๏€ฅ๏€’๏€’๏€ค๏€’๏€’๏€œ๏€’๏€’๏€ต VERWARMEN/KOELEN VERWARMEN/KOELEN VERWARMEN OK ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€๏€‘๏€Ž๏€”๏€•๏€๏€Ž๏€–๏€•๏€Ž๏€Ž๏€ ๏€—๏€Œ๏€‘๏€•๏€˜๏€๏€๏€“๏€’๏€‘๏€๏€™๏€๏€๏€š๏€›๏€‘๏€™๏€” instelling wijzigen ๏€”๏€Ÿ๏€จ ๏€ฅ๏€ญ OK ๏€›๏€ ๏€ก๏€œ๏€œ๏€ข๏€ฃ๏€ค๏€ฅ๏€ฆ๏€’๏€ณ๏€Ÿ๏€จ๏€œ๏€ฉ๏€ช๏€’๏€๏€‡๏€ƒ๏€Š๏€๏€Š๏€ƒ ๏€๏€œ๏€๏€ž ๏€™๏€ซ๏€๏€ญ๏€ช ๏€‘๏€ฎ๏€ฉ๏€ช terug naar ๏€๏€œ๏€Ÿ๏€ž het menu ๏€„๏€ฏ๏€‚๏€‚๏€ฏ๏€ƒ๏€๏€‚๏€‡ ๏€๏€ฉ๏€ฎ ๏€›๏€ฉ๏€ Instelling om de regelaar geschikt te maken voor het regelen van verwarming of koeling. 53 ๏€ ๏€ต๏€’๏€’๏€ข๏€’๏€’๏€ค๏€’๏€’๏€ช๏€’๏€’๏€ซ๏€’๏€’๏€ซ๏€’๏€’๏€๏€’๏€’๏€๏€’๏€’๏€œ๏€’๏€’๏€Ÿ๏€’๏€’๏€จ๏€’๏€’๏€ฅ๏€’๏€’๏€ค๏€’๏€’๏€œ๏€’๏€’๏€ต ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€๏€‘๏€Ž๏€”๏€•๏€๏€Ž๏€–๏€•๏€Ž๏€Ž๏€ ๏€—๏€Œ๏€‘๏€•๏€˜๏€๏€๏€“๏€’๏€‘๏€๏€™๏€๏€๏€š๏€›๏€‘๏€™๏€” ๏€”๏€Ÿ๏€จ ๏€ฅ๏€ญ ๏€›๏€ ๏€ก๏€œ๏€œ๏€ข๏€ฃ๏€ค๏€ฅ๏€ฆ๏€’๏€ณ๏€Ÿ๏€จ๏€œ๏€ฉ๏€ช๏€’๏€๏€‡๏€ƒ๏€Š๏€๏€Š๏€ƒ ๏€๏€œ๏€๏€ž ๏€๏€œ๏€Ÿ๏€ž ๏€™๏€ซ๏€๏€ญ๏€ช ๏€‘๏€ฎ๏€ฉ๏€ช ๏€„๏€ฏ๏€‚๏€‚๏€ฏ๏€ƒ๏€๏€‚๏€‡ ๏€๏€ฉ๏€ฎ ๏€›๏€ฉ๏€ 5.13 Schakeldifferentie selecteer SCHAKELDIFF. OK SCHAKELDIFF. 1.0K OK terug naar het menu wijzigt het knipperende cijfer Instelbaar tussen 0,1 en 3,0 K. 5.14 Minimum regelsignaal wijzigen selecteer 0-10V min(0-5V) 0-10V min(0-5V) 2.0 V OK instelling wijzigen OK terug naar het menu Opmerking: Wanneer er geen warmtevraag is, zal de PinTherm Connect een 0Vdc signaal uitsturen. 5.15 Maximum regelsignaal wijzigen selecteer 0-10V max(5-10V) OK 0-10V max(5-10V) 10.0 V instelling wijzigen OK terug naar het menu 5.16 Range regelsignaal wijzigen selecteer 0-10V Range(1-3) OK 0-10V Range(1-3) 1.0 instelling wijzigen OK terug naar het menu Met deze functie wordt bepaald wanneer het 0-10Vdc signaal wordt terug gemoduleerd tijdens warmtevraag. Wanneer dit is ingesteld op 1.0 zal de PinTherm Connect 1K onder de gewenste temperatuur het 0-10V signaal gaan terug moduleren. De range is instelbaar van 0.5 – 3.0 en staat standaard ingesteld op 1.0. ­­­ 54 5.17 ModBus selecteer MODBUS OK MODBUS INST. 001 wijzigt het knipperende cijfer OK terug naar het menu naar het volgende cijfer gaan NL Slave ID: instelbaar 1 - 247 Fabrieksinstelling: 1 5.18 Ethernet Info selecteer ETHERNET INFO OK IP-ADRES 192.168.001.100 OK MAC-ADRES 5410EC220037 OK terug naar het menu Weergave ingestelde IP-adres. 5.19 IP-instellingen selecteer IP INSTELLINGEN OK IP MODUS STATISCH OK instelling wijzigen IP-ADRES 192.168.001.100 SUBNET MASK 255.255.255.000 wijzigt het knipperende cijfer wijzigt het knipperende cijfer naar het volgende cijfer gaan naar het volgende cijfer gaan OK terug naar het menu DHCP - automatische toewijzing IP-adres Statisch - IP-adres instellen vast adres SUBnet Mask 5.20 Overwerktimer in- /uitschakelen Met deze functie bestaat de mogelijkheid om, buiten de ingestelde schakeltijden, handmatig 1, 2 of 3 uur naar de dagtemperatuur te schakelen. De gele led met het symbool gaat branden ten teken dat de functie is ingeschakeld. Tevens zal op het display rechtsonder de resterende tijd in minuten worden weergegeven voordat de functie weer uitschakelt en de PinTherm Connect weer functioneert op de nachttemperatuur. Tussentijds kan de functie ook weer worden uitgeschakeld door de drukknop in te drukken totdat de gele led uitgaat en het aantal minuten niet meer in het display worden weergegeven. 55 ๏€ ๏€‚ ๏€ƒ ๏€„ ๏€… ๏€† ๏€‡ ๏€ˆ ๏€‰ ๏€Š ๏€‚๏€ ๏€‚๏€‚ ๏€‚๏€ƒ ๏€‚๏€„ ๏€‚๏€… Zie onderstaande afbeelding. ๏€๏€‚ ๏€ˆ๏€ ๏€‡๏€…๏€ˆ ๏€“๏€‚๏€Ž๏€™๏€’ ๏€Œ๏€ˆ๏€† ๏€Œ๏€๏€Ž ๏€๏€‚ ๏€ˆ๏€ ๏€‡๏€…๏€ˆ ๏€ƒ๏€‚๏€„ ๏€Œ๏€ˆ๏€† ๏€Œ๏€๏€Ž ๏€Š๏€‡๏€…๏€‹๏€… ๏€๏€‚ ๏€ˆ๏€ ๏€‡๏€…๏€ˆ ๏€ƒ๏€‚๏€„ ๏€Œ๏€ˆ๏€† ๏€Œ๏€๏€Ž ๏€Š๏€‡๏€ˆ๏€—๏€… ๏€๏€‚ ๏€ˆ๏€ ๏€‡๏€…๏€ˆ ๏€ƒ๏€‚๏€„ ๏€Œ๏€ˆ๏€† ๏€Œ๏€๏€Ž ๏€Š๏€‡๏€ˆ๏€†๏€… 5.21 Schoorsteenvegerfunctie inschakelen 0-10V 0 ±12sec. Ingedrukt houden 10V 14:59 Maak gebruik van onderstaande drukknoppen om het toestel op een lagere voltage (deellast) te laten functioneren druk om de voltage te verhogen (max. 10V) druk om de voltage te verlagen ESC Hiermee beeindigd u de functie en keert u terug naar het hoofdscherm Hiermee kunt het toestel tijdelijk op vollast/deellast laten verwarmen om metingen e.d. te kunnen verrichten. Hieronder staat aangegeven hoe u deze functie kunt in-/uitschakelen. Na inschakeling blijft deze functie 15 minuten actief en zal daarna automatisch weer uitschakelen. ๏€ 5.22 Terugplaatsen fabrieksinstellingen PinTherm Connect ๏€„ ๏€… ๏€‡ ๏€ˆ ๏€‰ ๏€Š ๏€‚๏€ ๏€‚๏€‚ Als๏€‚ u deze ๏€ƒfunctie uitvoerd worden ๏€†alle fabrieksinstellingen weer teruggezet. Deze functie kan altijd worden uitgevoerd. Zie onderstaande afbeelding. ๏€๏€‚ ๏€™๏€๏€œ๏€๏€’๏€๏€‘๏€‘๏€๏€“ ๏€จ๏€‚๏€ง๏€œ๏€˜๏€๏€‰๏€๏€Ÿ๏€‚๏€‚๏€œ๏€ƒ๏€๏€“๏€ช ๏€‚๏€ƒ ๏€‚๏€„ ๏€‚๏€… ๏€จ๏€‚๏€ง๏€œ๏€˜๏€๏€‰๏€๏€Ÿ๏€‚๏€‚๏€œ๏€ƒ๏€๏€“ ๏€™๏€๏€œ๏€๏€’๏€๏€‘๏€ƒ๏€ฉ ๏€๏€‚ ๏€พ๏€‚๏€ƒ๏€ณ๏€œ๏€Ÿ๏€ž๏€’๏€Œ๏€ฅ๏€ฆ๏€œ๏€ฃ๏€ฉ๏€ญ๏€ต๏€ ๏€จ๏€ฎ๏€ญ๏€ฃ๏€œ๏€ฅ ๏€๏€๏€‘๏€๏€Ž๏€’๏€Œ๏€‘๏€‚๏€“๏€„๏€”๏€‚๏€„๏€ ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€๏€‘๏€Ž๏€”๏€•๏€๏€Ž๏€–๏€•๏€Ž๏€Ž๏€ ๏€๏€“๏€„๏€‘๏€˜๏€๏€™ ๏€—๏€Œ๏€‘๏€•๏€˜๏€๏€๏€“๏€’๏€‘๏€๏€™๏€๏€๏€š๏€›๏€‘๏€™๏€” ๏€ ๏€›๏€ ๏€ก๏€œ๏€œ๏€ข๏€ฃ๏€ค๏€ฅ๏€ฆ๏€’๏€ณ๏€Ÿ๏€จ๏€œ๏€ฉ๏€ช๏€’๏€๏€‡๏€ƒ๏€Š๏€๏€Š๏€ƒ ๏€๏€œ๏€๏€ž ๏€๏€œ๏€Ÿ๏€ž ๏€ต๏€’๏€’๏€ข๏€’๏€’๏€ค๏€’๏€’๏€ช๏€’๏€’๏€ซ๏€’๏€’๏€ซ๏€’๏€’๏€๏€’๏€’๏€๏€’๏€’๏€œ๏€’๏€’๏€Ÿ๏€’๏€’๏€จ๏€’๏€’๏€ฅ๏€’๏€’๏€ค๏€’๏€’๏€œ๏€’๏€’๏€ต ๏€„๏€…๏€‡ ๏€˜๏€ค๏€œ๏€ฉ๏€ช๏€œ๏€œ๏€’๏€ต๏€œ๏€œ๏€ฉ๏€๏€’๏€ญ๏€’๏€๏€œ๏€ฉ๏€ญ๏€ฆ๏€’๏€ฅ๏€ซ๏€ซ๏€ฉ ๏€จ๏€œ๏€๏€’๏€จ๏€ฎ๏€ฎ๏€ ๏€ฃ๏€ณ๏€Ÿ๏€จ๏€œ๏€ฉ๏€ช๏€’๏€œ๏€ฅ๏€’๏€ผ๏€ญ๏€ข๏€ข๏€œ๏€ฅ๏€’๏€ฃ๏€œ ๏€ ๏€ซ๏€ก๏€ฉ๏€ค๏€œ๏€ต๏€ณ๏€บ๏€ซ๏€ซ๏€ฉ๏€ฃ๏€œ๏€ฅ๏€’๏€ฅ๏€ค๏€œ๏€๏€’๏€บ๏€ฎ๏€ฉ๏€ฃ๏€œ๏€ฅ ๏€๏€œ๏€ฉ๏€ญ๏€ฆ๏€ฆ๏€œ๏€ฐ๏€ข๏€ซ๏€ซ๏€๏€ณ๏€๏€ฟ ๏€๏€‚ ๏€…๏€†๏€‡๏€…๏€ˆ ๏€ƒ๏€‚๏€„ ๏€Œ๏€ˆ๏€‹๏€Œ๏€๏€Ž 6.0 Afdanken PinTherm Connect Wanneer de PinTherm Connect wordt vervangen of verwijdert dient deze conform landelijke en/ of plaatselijke verordeningen te worden gerecycled of vernietigd. 7.0 Modbus - Communicatie [12] - Modbus-lijst [13] 56 ๏€™๏€ซ๏€๏€ญ๏€ช ๏€‘๏€ฎ๏€ฉ๏€ช ๏€„๏€ฏ๏€‚๏€‚๏€ฏ๏€ƒ๏€๏€‚๏€‡ 8.0 Aansluitmogelijkheden PinTherm Connect PinTherm Connect 06.29.108 MA 08:01 DAG 18ºC X:060 NL 0 I RESET OK ESC L N Voedingsklemmen (230Vac/50Hz) 21 - 22 Continue ventileren 21 - 23 Verwarmen/koelen 24 - 25 Storingslamp 25 - 26 Reset + - 0-10Vdc (Verwarmen/koelen) 11 - 12 Externe temperatuursensor A - B MODBUS RTU (R ground) RJ 45 connector Internet / Modbus TCP/IP 13 - 14 Contact externe ventilator Waarschuwing: Gevaarlijke spanning aanwezig op N, L, 13, 14, 21, 22, 23, 24, 25 en 26 Met de PinTherm Connect mogen alleen toestellen aangestuurd worden die voldoen aan de veiligheidsvoorschriften zoals vastgelegd in EN-IEC 61010-1. 57 Proszฤ™ przeczytaฤ‡ niniejszy dokument przed instalacjฤ… urzฤ…dzenia Ostrzeลผenie Nieprawidล‚owy montaลผ, regulacja, modyfikacje, naprawa lub konserwacja mogฤ… prowadziฤ‡ do strat materialnych, obraลผeล„ ciaล‚a lub wybuchu. Wszystkie czynnoล›ci muszฤ… byฤ‡ wykonywane przez upowaลผnionych, kwalifikowanych specjalistów. Gwarancja traci waลผnoล›ฤ‡ w przypadku, gdy urzฤ…dzenie nie zostanie zainstalowane zgodnie ze wskazówkami. Niniejsze urzฤ…dzenie nie jest przeznaczone do uลผytku przez dzieci lub osoby o obniลผonych moลผliwoล›ciach fizycznych, sensorycznych czy umysล‚owych ani teลผ osoby nieposiadajฤ…ce odpowiedniego doล›wiadczenia czy wiedzy, chyba ลผe osoby takie pozostajฤ… pod nadzorem lub zostaล‚y przeszkolone w zakresie uลผytkowania urzฤ…dzenia przez osobฤ™ odpowiedzialnฤ… za ich bezpieczeล„stwo. Naleลผy dopilnowaฤ‡, aby dzieci nie uลผywaล‚y tego urzฤ…dzenia do zabawy. 58 1.0 Spis treล›ci 2.0 Informacje ogólne 2.1 Zastrzeลผenia odnoล›nie zmian 2.2 Ogólne ostrzeลผenia str. str. 4 4 str. str. 4 5 str. 5 str. 5 4.0 Instalacja 4.1 Informacje ogólne 4.2 Montaลผ termostatu PinTherm Connect 4.3 Montaลผ zewnฤ™trznego czujnika temperatury pomieszczenia (opcjonalnie) str. str. str. 6 6 6 5.0 Instrukcja obsล‚ugi 5.1 Objaล›nienie funkcji przycisków i wskaลบników 5.2 Objaล›nienie pozycji na wyล›wietlaczu 5.3 Pierwsze uruchomienie termostatu PinTherm Connect 5.4 Aktywacja menu uลผytkownika 5.5 Wprowadzanie/zmiana programu 5.6 Zmiana temperatury dziennej/nocnej 5.7 Zmiana godziny i daty 5.8 Ustawienia wakacyjne 5.9 Zmiana kodu menu 5.10 Zmiana jฤ™zyka 5.11 Skalowanie temperatury 5.12 Ogrzewanie/Chล‚odzenie 5.13 Róลผnica zaล‚ฤ…czania 5.14 Zmiana minimalnej wartoล›ci sygnaล‚u sterujฤ…cego 5.15 Zmiana maksymalnej wartoล›ci sygnaล‚u sterujฤ…cego 5.16 Zmiana zakresu sygnaล‚u sterujฤ…cego 5.17 Modbus 5.18 Informacja o Ethernet 5.19 Ustawienia IP 5.20 Wล‚ฤ…czanie/wyล‚ฤ…czanie zegara dodatkowych godzin 5.21 Uruchamianie funkcji oczyszczania komina 5.22 Przywracanie ustawieล„ domyล›lnych termostatu PinTherm Connect str. str. str. str. str. str. str. str. str. str. str. str. str. str. str. str. str. str. str. str. str. str. 7 8 8 9 9 10 10 10 10 11 11 11 12 12 12 12 13 13 13 13 14 14 6.0 Utylizacja termostatu PinTherm Connect str. 14 7.0 Modbus str. 14 8.0 Moลผliwoล›ci poล‚ฤ…czenia termostatu PinTherm Connect str. 15 Zaล‚ฤ…cznik I Schematy okablowania Zaล‚ฤ…cznik II Modbus str. str. 87 94 3.0 Dane techniczne 3.1 Dane techniczne termostatu PinTherm Connect 3.2 Dane techniczne zewnฤ™trznego czujnika temperatury pomieszczenia (opcjonalnie) 3.3 Tabela rezystancji (zewnฤ™trznego) czujnika temperatury pomieszczenia 3.4 Ustawienia domyล›lne termostatu PinTherm Connect PL 59 2.0 Informacje ogólne 2.1 Zastrzeลผenia odnoล›nie zmian Celem producenta jest ciฤ…gล‚e udoskonalanie swoich produktów, w zwiฤ…zku z czym zastrzega on sobie prawo do wprowadzania zmian w specyfikacjach bez wczeล›niejszego uprzedzenia. Szczegóล‚owe dane techniczne uznaje siฤ™ za prawidล‚owe, jednak nie stanowiฤ… one podstawy umowy lub gwarancji. Wszelkie zamówienia sฤ… realizowane zgodnie ze standardowymi postanowieniami ogólnych warunków firmy dotyczฤ…cych sprzedaลผy i dostaw (dostฤ™pnych na ลผyczenie). 2.2 Ogólne ostrzeลผenia Instalacja urzฤ…dzenia powinna odbywaฤ‡ siฤ™ zgodnie obowiฤ…zujฤ…cymi normami lokalnymi i/lub krajowymi. Z tego powodu zaleca siฤ™, aby instalacja termostatu PinTherm Connect zostaล‚a przeprowadzona przez kompetentnego i wykwalifikowanego montera, z uwzglฤ™dnieniem ustawodawstwa krajowego i miฤ™dzynarodowego. Nieprawidล‚owo przeprowadzona instalacja, regulacja, modyfikacja oraz czynnoล›ci konserwacyjne lub naprawcze prowadzฤ… do wygaล›niฤ™cia gwarancji. Zawsze wyล‚ฤ…czaj zasilanie 230 V przed podล‚ฤ…czeniem zacisków. Napiฤ™cie sieciowe w urzฤ…dzeniu PinTherm Connect musi byฤ‡ wyล‚ฤ…czane w sposób dwubiegunowy za pomocฤ… staล‚ego przeล‚ฤ…cznika, który jest odpowiedni dla napiฤ™cia 250VAC / 10A i jest zgodny z obowiฤ…zujฤ…cymi przepisami bezpieczeล„stwa. Sterownika PinTherm Connect uลผywaฤ‡ moลผna tylko do sterowania urzฤ…dzeniami speล‚niajฤ…cymi wymogi normy EN-IEC 61010-1. Przy uลผyciu mokrej szmatki, wytrzyj obudowฤ™ sterownika PinTherm Connect. Nie uลผywaj rozpuszczalników. Nie ma wymagaล„ dotyczฤ…cych wentylacji w bezpoล›rednim sฤ…siedztwie sterownika. Uwaga - ryzyko poraลผenia prฤ…dem. ! Uwaga - ogólne ostrzeลผenie,naraลผenie na niebezpieczeล„stwo. Pod zaciskami przyล‚ฤ…czeniowymi, które oznaczono, moลผe znajdowaฤ‡ siฤ™ napiฤ™cie. ! 3.0 Dane techniczne 3.1 Dane techniczne termostatu PinTherm Connect • Oznaczenie typu : PinTherm Connect • Numer produktu : 06 29 108 • Zasilanie PinTherm Connect : 90 – 240 VAC / 47-63Hz • Wล‚asne zuลผycie energii : < 9W • Zegar : zegar 24-godzinny z funkcjฤ… automatycznego przeล‚ฤ…czania trybów lato/zima • Przeล‚ฤ…czanie programów : 3 programy dziennie • Przeล‚ฤ…cznik dyferencyjny : 0,1 - 3K • Wymiary : 166 x 160 x 106mm (lxwxh) • Waga : 880 gram • Klasa ochrony : IP-54 • ลšrodowisko instalacji : Transport/przechowywanie: -20°C do +70°C. Praca: -10°C do +60°C Wilgotnoล›ฤ‡ wzglฤ™dna: 0-90% przy braku kondensacji Instalacja maksymalnie 2000 metrów nad poziomem morza. 60 • Kategoria przepiฤ™ciowa : • Poziom zanieczyszczeล„ : • Przeล‚ฤ…cznik(i)* : • Ustawienia temperatury : • Zegar nadgodzin : • Kalibracja : • Ogrzewanie/chล‚odzenie : • 0-10 VDC : • Czujnik : • Jฤ™zyki : • Bezpiecznik : 11 2 Ogrzewanie: 230Vac/16A (4A) Pozostaล‚e: 230Vac/10A (2,5A) 0 do 39°C per 1°C z moลผliwoล›ciฤ… regulacji moลผliwoล›ฤ‡ regulacji 1, 2 lub 3 godziny (060, 120, 180) moลผliwoล›ฤ‡ regulacji od -3.5°C do +3.5°C Kontakt odwracalny dla ogrzewania i chล‚odzenia styk zasilajฤ…cy 0-10 VDC dla ogrzewania i chล‚odzenia zewnฤ™trzny czujnik temperatury pomieszczeniowej (06 29 086) NL/EN/DE/FR/PL/RO/LT 6A PL * Styki przekaลบnikowe sฤ… przeล‚ฤ…cznikami funkcjonalnymi, a nie wyล‚ฤ…cznikami bezpieczeล„stwa. 3.2 Dane techniczne zewnฤ™trznego czujnika temperatury pomieszczenia (opcjonalnie) • Oznaczenie typu : RSTF NTC4,7K • Numer produktu : 06 29 086 • Rezystancja : NTC 4K7 • Wymiary : 79 x 81 x 26mm (lxwxh) • Masa : 46 grammes • Przyล‚ฤ…cza elektryczne : 0.75 -1.5mm² • Stopieล„ ochrony : IP-30 3.3 Tabela rezystancji (zewnฤ™trznego) czujnika temperatury pomieszczenia -15°C -10°C -5°C 32.937kโ„ฆ 25.217kโ„ฆ 19.392kโ„ฆ 0°C 15.040kโ„ฆ 5°C 11.743kโ„ฆ 10°C 9.241kโ„ฆ 15°C 7.330kโ„ฆ 20°C 5.855kโ„ฆ 35°C 3.071kโ„ฆ 40°C 2.512kโ„ฆ 45°C 2.066kโ„ฆ 50°C 1.709kโ„ฆ 25°C 4.700kโ„ฆ 30°C 3.777kโ„ฆ 3.4 Ustawienia domyล›lne termostatu PinTherm Connect • Kod menu : 1000 • Program : Pn, Wt, ลšr, Cz, Pt 07:30-17:30 So, Nd 00:00-00:00 • Temperatura pomieszczenia : Temperatura dzienna 18°C Temperatura nocna 08°C • Skalowanie temperatury : +0.0 • Róลผnica zaล‚ฤ…czania : 1K • Ogrzewanie/Chล‚odzenie : Ogrzewanie • 0-10V range : 1K • 0-10V min : 0V • 0-10V max : 10V • Modbus : Slave ID 001 • Ustawienia IP : statyczny 61 4.0 Instalacja 4.1 Informacje ogólne Po rozpakowaniu termostatu PinTherm Connect i czujnika zewnฤ™trznego (jeล›li zostaล‚ doล‚ฤ…czony do termostatu), naleลผy sprawdziฤ‡ urzฤ…dzenia pod wzglฤ™dem uszkodzeล„. Sprawdziฤ‡ zgodnoล›ฤ‡ typu/ modelu urzฤ…dzeล„ oraz dziaล‚anie po podล‚ฤ…czeniu do ลบródล‚a zasilania. 4.2 Montaลผ termostatu PinTherm Connect Okreล›liฤ‡ odpowiednie miejsce do zamontowania termostatu PinTherm Connect. Zamontuj urzฤ…dzenie PinTherm Connect na stabilnej powierzchni o minimalnym udลบwigu 4 kg. Termostat PinTherm Connect zaleca siฤ™ umieszczaฤ‡ na wysokoล›ci ±1,5 m od podล‚ogi, w dobrze dostฤ™pnym miejscu. Naleลผy uลผywaฤ‡ tylko dล‚awików kablowych wyposaลผonych w zabezpieczenie przed odksztaล‚ceniem, o minimalnej klasie odpornoล›ci ogniowej UL94V2. Przed podล‚ฤ…czeniem jakichkolwiek przewodów, sprawdลบ, czy zasilanie zostaล‚o wyล‚ฤ…czone. Jeล›li tak nie jest, najpierw naleลผy wyล‚ฤ…czyฤ‡ zasilanie. Po wyล‚ฤ…czeniu zasilania urzฤ…dzenia, do którego ma nastฤ…piฤ‡ podล‚ฤ…czenie, naleลผy równieลผ zapoznaฤ‡ siฤ™ z dokumentacjฤ… technicznฤ… / instrukcjฤ… obsล‚ugi danego urzฤ…dzenia. Podล‚ฤ…cz urzฤ…dzenie PinTherm Connect zgodnie z dostarczonym schematem elektrycznym, znajdujฤ…cym siฤ™ z tyล‚u niniejszej instrukcji technicznej. Aby wybraฤ‡ prawidล‚owy schemat poล‚ฤ…czeล„, musisz wiedzieฤ‡, jakiego typu urzฤ…dzenie chcesz podล‚ฤ…czyฤ‡ do sterownika PinTherm Connect. W celu dokonania wyboru zapoznaj siฤ™ takลผe z Zaล‚ฤ…cznikiem I. Podczas stosowania sygnaล‚u 0-10VDC, na podstawie poniลผszej tabeli moลผna okreล›liฤ‡ odpowiedniฤ… ล›rednicฤ™ i dล‚ugoล›ฤ‡ kabla. ลšrednica 0.8mm2 1.0mm2 1.5mm2 Dล‚ugoล›ฤ‡ 80 metrów 100 metrów 150 metrów Zasiฤ™gnฤ…ฤ‡ informacji na temat stosowanego kabla ekranowanego. 4.3 Montaลผ zewnฤ™trznego czujnika temperatury pomieszczenia (opcjonalnie) Umieล›ciฤ‡ zewnฤ™trzny czujnik pomieszczeniowy poza strefฤ… wystฤ™powania przeciฤ…gów, w pobliลผu uลผฤ…dzenia na wysokoล›ci okoล‚o. 1,5 m od podล‚ogi i podล‚ฤ…cz czujnik do odpowiednich zacisków w urzฤ…dzeniu PinTherm Connect. Na podstawie poniลผszej tabeli moลผna okreล›liฤ‡ odpowiedniฤ… ล›rednicฤ™ i dล‚ugoล›ฤ‡ kabla. ลšrednica 0.8mm2 1.0mm2 1.5mm2 62 Dล‚ugoล›ฤ‡ 80 meter 100 meter 150 meter Zasiฤ™gnฤ…ฤ‡ informacji na temat stosowanego kabla ekranowanego. 5.0 Instrukcja obsล‚ugi 5.1 Objaล›nienie funkcji przycisków i wskaลบników A PinTherm Connect 06.29.108 PN 08:01 18ºC DZIEN X:060 H B D F C 0 E I G M RESET I A B C D E F G H I J K L M N O - PL OK N ESC O J K L Podล›wietlany wyล›wietlacz (patrz równieลผ 5.2) Przycisk wล‚ฤ…czania lub wyล‚ฤ…czania ogrzewania Dioda wskazujฤ…ca wล‚ฤ…czenie funkcji ogrzewania Przycisk wล‚ฤ…czania lub wyล‚ฤ…czania wentylacji Dioda wskazujฤ…ca wล‚ฤ…czenie funkcji wentylacji Przycisk resetowania urzฤ…dzenia w przypadku awarii (palnika) Dioda informujฤ…ca o awarii (palnika) Przycisk aktywacji menu uลผytkownika lub przejล›cia do nastฤ™pnej wartoล›ci liczbowej Przycisk potwierdzenia dokonanego wyboru/zmiany lub przejล›cia do nastฤ™pnej pozycji menu Przycisk opuszczenia menu lub ustawieล„ bez zastosowania wprowadzonych zmian Przycisk wล‚ฤ…czania lub wyล‚ฤ…czania zegara dodatkowych godzin Przycisk ๏€ต+๏€ถ­– sล‚uลผฤ…cy do zmiany ustawieล„ Dioda informujฤ…ca o ลผฤ…daniu uruchomienia ogrzewania (wล‚ฤ…czony palnik) Dioda wskazujฤ…ca wล‚ฤ…czenie wentylatora Dioda wskazujฤ…ca wล‚ฤ…czenie funkcji zegara dodatkowych godzin 63 5.2 Objaล›nienie pozycji na wyล›wietlaczu B A PN C 08:01 18ºC DZIEN X:060 D E A B C D E Dzieล„ tygodnia Aktualna godzina Pomiar temperatury (°C). Liczba minut pozostaล‚a do wyล‚ฤ…czenia zegara dodatkowych godzin i przestawienia termostatu PinTherm Connect na temperaturฤ™ nocnฤ…. Wskaลบnik trybu dziennego (DZIEลƒ) lub nocnego (NOC) termostatu PinTherm Connect ustawiany na podstawie temperatury dziennej i nocnej 5.3 Pierwsze uruchomienie termostatu PinTherm Connect Podczas pierwszego uruchomienia termostatu PinTherm Connect naleลผy ustawiฤ‡ odpowiedni jฤ™zyk (dostฤ™pne jฤ™zyki: NL, EN, DE, FR, PL, RO, LT) oraz prawidล‚owฤ… godzinฤ™ i datฤ™. Nastฤ™pnie termostat PinTherm Connect wyล›wietla ekran gล‚ówny. WYBIERZ JEZYKE ENGLISH OK SO 01-01-2006 00:00:00 wybór odpowiedniego jฤ™zyka zmiana migajฤ…cej cyfry przejล›cie do nastฤ™pnej cyfry PN Dostฤ™pne jฤ™zyki: NL, EN, DE, FR, PL, RO, LT 64 08:00 DZIEN 16°C OK 5.4 Aktywacja menu uลผytkownika PN 08:01 DZIEN 16°C OK WPROWADZ KOD 0000 OK zmieล„ mrugajฤ…cฤ… liczbฤ™ kod menu ustawieล„ fabrycznych 1000 przejdลบ do nastฤ™pnego numero WPROWADZ/ZMIEN PROGRAM PL wybierz wymagane menu ESC wyjdลบ z menu i wróฤ‡ do okna glównego Ustawienia mogฤ… byฤ‡ zmieniane za pomocฤ… nastฤ™pujฤ…cych pozycji menu: – Wprowadลบ/zmieล„ program – Zmieล„ temp. dziennฤ…/nocnฤ… – Zmieล„ czas/datฤ™ – Ustawienia wakacyjne – Zmieล„ kod menu – Zmieล„ jฤ™zyk – Skalowanie temp. – 0-10V min 0-5V – 0-10V max 5-10V – 0-10V range (1-3) – Modbus – Ustawienia IP 5.5 Wprowadzanie/zmiana programu WPROWADZ/ZMIEN PROGAM OK PONIEDZIALEK 1 07:30 -> 17:00 OK PONIEDZIALEK 2 --:-- -> --:-- OK zmieล„ mrugajฤ…cฤ… liczbฤ™ przejdลบ do nastฤ™pnego numero PONIEDZIALEK 3 --:-- -> --:-zmieล„ mrugajฤ…cฤ… liczbฤ™ OK WTOREK 1 07:30 -> 17:00 etc. NIEDZIELA 3 --:-- -> --:-- OK powrót do menu przejdลบ do nastฤ™pnego numero 65 5.6 Zmiana temperatury dziennej/nocnej wybierz WPROWADZ/ZMIEN TEMPERATURE OK TEMP. DZIENNA 18°C OK zmieล„ mrugajฤ…cฤ… liczbฤ™ przejdลบ do nastฤ™pnego numero TEMP. NOCNA 08°C OK powrót do menu zmieล„ mrugajฤ…cฤ… liczbฤ™ przejdลบ do nastฤ™pnego numero 5.7 Zmiana godziny i daty wybierz ZMIEN CZAS/DATE OK PN 23-03-2009 09:10:00 zmieล„ mrugajฤ…cฤ… liczbฤ™ OK powrót do menu przejdลบ do nastฤ™pnego numero 5.8 Ustawienia wakacyjne wybierz USTAWIENIA WAKACYJNE OK TRYB WAKACJI AKT ON OK OD: 01-07-2017 DO: 01-08-2017 zmieล„ mrugajฤ…cฤ… liczbฤ™ wybierz wล‚ฤ…cz lub wyล‚ฤ…cz OK powrót do menu przejdลบ do nastฤ™pnego numero W czasie ustawionego bloku czasowego sterowanie bฤ™dzie odbywaฤ‡ siฤ™ w oparciu o temperaturฤ™ nocnฤ…. 5.9 Zmiana kodu menu wybierz ZMIEN KOD MENU OK WYBIERZ NOWY KOD 1000 zmieล„ mrugajฤ…cฤ… liczbฤ™ przejdลบ do nastฤ™pnego numero Nowy kod menu 66 OK powrót do menu 5.10 Zmiana jฤ™zyka wybierz ZMIEN JEZYK OK WYBIERZ JEZYK POLSKI wybierz ลผฤ…dany jฤ™zyk OK powrót do menu Dostฤ™pne jฤ™zyki: NL, EN, DE, FR, PL, RO, LT. 5.11 Skalowanie temperatury Jeล›li termostat PinTherm Connect zostaล‚ zamontowany w miejscu niekorzystnym do pomiaru temperatury, temperatura mierzona przez termostat PinTherm Connect moลผe odbiegaฤ‡ od temperatury rzeczywistej. Róลผnicฤ™ temperatur moลผna zrównowaลผyฤ‡ dziฤ™ki funkcji skalowania umoลผliwiajฤ…cej ustawienie wartoล›ci korygujฤ…cej. Jeล›li funkcja ta nie przynosi poลผฤ…danych rezultatów, istnieje równieลผ moลผliwoล›ฤ‡ zamontowania zewnฤ™trznego czujnika temperatury pomieszczenia przy termostacie PinTherm Connect . Przykล‚ad: Rzeczywista temperatura to 18°C, a na wyล›wietlaczu termostatu PinTherm Connect pojawia siฤ™ 20°C. W tym przypadku temperatura na wyล›wietlaczu jest o 2°C za wysoka - wartoล›ฤ‡ korygujฤ…cฤ… powinna wynieล›ฤ‡ -2°C. wybierz SKALOWANIE TEMP. SKALOWANIE TEMP. + 0.0°C OK zmieล„ mrugajฤ…cฤ… liczbฤ™ OK powrót do menu przejdลบ do nastฤ™pnego numero Wartoล›ฤ‡ korygujฤ…cฤ… moลผna regulowaฤ‡ od -3,5°C do +3,5°C 5.12 Ogrzewanie/Chล‚odzenie wybierz OGRZEW./CHLODZ. OK OGRZEW./CHLODZ. OGRZEWANIE zmiana ustawien OK powrót do menu Ustawienie trybu sterowania ogrzewaniem lub chล‚odzeniem. 67 PL 5.13 Róลผnica zaล‚ฤ…czania wybierz PRZELACZANIE OK PRZELACZANIE 1.0K wybór odpowiedniego jezyka OK powrót do menu Moลผliwoล›ฤ‡ regulacji miฤ™dzy 0.1 a 3.0 K. 5.14 Zmiana minimalnej wartoล›ci sygnaล‚u sterujฤ…cego wybierz 0-10V min(0-5V) OK 0-10V min(0-5V) 2.0 V zmiana ustawieล„ OK powrót do menu Uwaga: W przypadku braku koniecznoล›ci uruchomienia funkcji ogrzewania termostat PinTherm Connect wysyล‚a sygnaล‚ o wartoล›ci 0 V DC. 5.15 Zmiana maksymalnej wartoล›ci sygnaล‚u sterujฤ…cego wybierz 0-10V max(5-10V) OK 0-10V max(5-10V) 10.0 V zmiana ustawieล„ OK powrót do menu 5.16 Zmiana zakresu sygnaล‚u sterujฤ…cego Funkcja ta pozwala okreล›liฤ‡, kiedy sygnaล‚ o zakresie 0-10 V DC zostaje ponownie zmodulowany podczas ลผฤ…dania wล‚ฤ…czenia ogrzewania. Gdy jest on ustawiony na wartoล›ฤ‡ 1.0, termostat PinTherm Connect ponownie zmoduluje sygnaล‚ 0-10 V o 1 K poniลผej ลผฤ…danej temperatury. wybierz 0-10V Range(1-3) OK 0-10V Range(1-3) 1.0 zmiana ustawieล„ Zakres jest ustawiony w przedziale 0.5-3.0, a jego wartoล›ฤ‡ domyล›lna to 1.0. ­­ 68 OK powrót do menu 5.17 ModBus wybierz USTAWIENIA MODBUS OK USTAWIENIA MODBUS 001 OK powrót do menu wybór odpowiedniego jezyka przejscie do nastepnej cyfry ID Slave: regulacja 1 - 247 Ustawienie fabryczne: 1 PL 5.18 Informacja o Ethernet wybierz ETHERNET INFO OK ADRES IP 192.168.001.100 OK ADRES MAC 5410EC220037 OK powrót do menu Ustawienia adresu IP na wyล›wietlaczu. 5.19 Ustawienia IP wybierz USTAWIENIA IP OK TRYB IP STATIQ OK zmiana ustawien ADRES IP 192.168.001.100 MASKA PODSIECI 255.255.255.000 OK powrót do menu zmiana migajacej cyfry zmiana migajacej cyfry przejscie do nastepnej cyfry przejscie do nastepnej cyfry DHCP - automatyczne przypisywanie adresu IP Statyczny - ustaw staล‚y adres IP Maska podsieci 5.20 Wล‚ฤ…czanie/wyล‚ฤ…czanie zegara dodatkowych godzin Funkcja ta pozwala na rฤ™czne przeล‚ฤ…czanie na temperaturฤ™ dziennฤ… o 1, 2 lub 3 godziny poza ustawionymi programami. Aktywacja tej funkcji powoduje zapalenie siฤ™ ลผóล‚tej diody . Ponadto w prawym dolnym rogu wyล›wietlacza pojawia siฤ™ czas liczony w minutach, jaki pozostaล‚ do wyล‚ฤ…czenia funkcji i przywrócenia termostatu Pin Therm Connect do trybu temperatury nocnej. W miฤ™dzyczasie funkcja ta moลผe równieลผ zostaฤ‡ wyล‚ฤ…czona za pomocฤ… przycisku – do zgaล›niฤ™cia ลผóล‚tej diody i znikniฤ™cia liczby minut z wyล›wietlacza. 69 Patrz poniลผszy przykล‚ad. PN 17:01 NOC 18°C PN 17:01 18°C DZIEN X:060 PN 17:01 18°C DZIEN X:120 PN 17:01 18°C DZIEN X:180 5.21 Uruchamianie funkcji oczyszczania komina Funkcja umoลผliwia czasowe nagrzanie instalacji przy caล‚kowitym/czฤ™ล›ciowym obciฤ…ลผeniu w celu przeprowadzenia pomiarów itp. Instrukcja aktywacji/dezaktywacji tej funkcji znajduje siฤ™ poniลผej. Po wล‚ฤ…czeniu funkcja ta pozostaje aktywna przez 15 minut, po czym wyล‚ฤ…cza siฤ™ automatycznie. 0-10V 0 Przytrzymaฤ‡ wciล›niฤ™ty przez ±12 s 10V 14:59 Uลผyฤ‡ poniลผszych przycisków, aby urzฤ…dzenie pracowaล‚o na wysokim napiฤ™ciu (przy czฤ™ล›ciowym obciฤ…ลผeniu) Nacisnฤ…ฤ‡, aby zwiฤ™kszyฤ‡ napiฤ™cie (maks. 10 V) Nacisnฤ…ฤ‡, aby zmniejszyฤ‡ napiฤ™cie (maks. ESC Nacisnฤ…ฤ‡, aby zatrzymaฤ‡ dziaล‚anie funkcji i powróciฤ‡ do gล‚ównego ekranu 5.22 Przywracanie ustawieล„ domyล›lnych termostatu PinTherm Connect Przeprowadzenie tej operacji spowoduje przywrócenie wszystkich ustawieล„ domyล›lnych. Operacjฤ™ moลผna przeprowadziฤ‡ w kaลผdej chwili. Patrz poniลผszy przykล‚ad. OK naciล›nij i przytrzymaj przez okoล‚o 12 sekund. PRZYWROCIC UST. DOMYSLNE? OK UST. DOMYSLNE PRZYWROCONE! SELECT LANGUAGE ENGLISH ESC w ten sposób wrócisz do okna gล‚ównego, a wartoล›ci fabryczne nie zostanฤ… zastฤ…pione! PN 08:01 DZIEN 16°C 6.0 Utylizacja termostatu PinTherm Connect Wymiana lub usuwanie termostatu PinTherm Connect w celu jego recyklingu lub wyrzucenia powinna byฤ‡ zgodna z lokalnymi i/lub krajowymi przepisami. 7.0 Modbus - Komunikacja [12] - Lista-Modbus [13] 70 8.0 Moลผliwoล›ci poล‚ฤ…czenia termostatu PinTherm Connect PinTherm Connect 06.29.108 PN 08:01 DZIEN 18ºC X:060 0 PL I RESET OK ESC L N Zaciski (230Vac/50Hz) 21 - 22 Ciฤ…gล‚a wentylacja 21 - 23 Ogrzewanie/chล‚odzenie 24 - 25 Dioda sygnalizacji awarii 25 - 26 Styk resetowania + - 0-10Vdc (Ogrzewanie/chล‚odzenie) 11 - 12 Zewnฤ™trzny czujnik temperatury A - B MODBUS RTU (R ground) RJ 45 connector Internet / Modbus TCP/IP 13 - 14 Kontakt zewnฤ™trzny wentylatora Uwaga: Wysokie napiฤ™cie pod zaciskami N, L, 13, 14, 21, 22, 23, 24, 25 i 26 Sterownika PinTherm Connect uลผywaฤ‡ moลผna tylko do sterowania urzฤ…dzeniami speล‚niajฤ…cymi wymogi dotyczฤ…ce bezpieczeล„stwa zgodnie z normฤ… EN-IEC 61010-1. 71 Citiลฃi acest document înainte de a începe instalarea ลŸi operarea Avertisment! Instalarea, setarea, modificarea, repararea sau întreลฃinerea incorectฤƒ poate duce la daune materiale sau la rฤƒniri. Toate activitฤƒลฃile trebuie efectuate de cฤƒtre personal calificat, aprobat. Dacฤƒ dispozitivul nu este aลŸezat conform instrucลฃiunilor, garanลฃia va fi anulatฤƒ. Acest aparat nu este destinat utilizฤƒrii de cฤƒtre copii sau persoane cu un handicap fizic, senzorial sau mintal, sau care nu au experienลฃa necesarฤƒ, cu excepลฃia cazurilor în care sunt supravegheate, sau au fost instruite sฤƒ foloseascฤƒ aparatul, de cฤƒtre o persoanฤƒ responsabilฤƒ cu siguranลฃa lor. Copiii trebuie supravegheaลฃi, pentru a vฤƒ asigura cฤƒ nu se joacฤƒ cu aparatul. 72 1.0 Cuprins 2.0 Informaลฃii generale 2.1 Modificฤƒri 2.2 Atenลฃionฤƒri generale pagina pagina 4 4 3.0 Detalii tehnice 3.1 Detalii tehnice PinTherm Connect 3.2 Detalii tehnice pentru senzor de camerฤƒ extern (optional) 3.3 Tabel rezistenลฃฤƒ senzor glob extern (optional) 3.4 Setฤƒrile din fabricฤƒ pentru PinTherm Connect pagina pagina pagina pagina 4 5 5 5 4.0 Instalarea 4.1 Informaลฃii generale 4.2 Asamblarea PinTherm Connect 4.3 Asamblarea senzorului glob extern pagina pagina pagina 6 6 6 5.0 Manual depanare 5.1 Explicarea butoanelor ลŸi LED-urilor 5.2 Explicarea afiลŸajului 5.3 Operarea iniลฃialฤƒ a PinTherm Connect 5.4 Activarea meniului utilizatorului 5.5 Introducere/schimbare orฤƒ 5.6 Schimbarea temperaturilor pentru zi/noapte 5.7 Schimbarea orei ลŸi datei 5.8 Setari de vacanta 5.9 Schimbaลฃi codul de meniu 5.10 Schimbare limbฤƒ 5.11 Calibrare 5.12 Incalzire/racire 5.13 Diferenta de comutare 5.14 Schimbarea semnalului de control minim 5.15 Schimbarea semnalului de control maxim 5.16 Schimbati intervalul de semnal de control 5.17 Modbus 5.18 Informatii Ethernet 5.19 Setari IP 5.20 Pornire/oprire timp suplimentar 5.21 Porniti functia de stergere a cosului de fum 5.22 Setฤƒrile din fabricฤƒ pentru PinTherm Connect pagina pagina pagina pagina pagina pagina pagina pagina pagina pagina pagina pagina pagina pagina pagina pagina pagina pagina pagina pagina pagina pagina 7 8 8 9 9 10 10 10 10 11 11 11 12 12 12 12 13 13 13 13 14 14 6.0 Aruncarea PinTherm Connect pagina 14 7.0 Modbus pagina 14 8.0 Posibilitฤƒลฃi de cablaj pentru PinTherm Connect pagina 15 Anexa I Schiลฃฤƒ cablaj Anexa II Modbus pagina pagina 87 94 RO 73 2.0 Informaลฃii generale 2.1 Modificฤƒri Producฤƒtorul se angajeazฤƒ sฤƒ-ลŸi îmbunฤƒtฤƒลฃeascฤƒ constant produsele ลŸi îลŸi rezervฤƒ dreptul de a aduce modificฤƒri în specificaลฃii fฤƒrฤƒ notificare prealabilฤƒ. Detaliile tehnice se presupun a fi corecte, însฤƒ nu stau la baza unui contract sau a unei garanลฃii. Toate comenzile sunt acceptate în conformitate cu termenii standard ai condiลฃiilor noastre de vânzare ลŸi livrare (disponibile la cerere). 2.2 Atenลฃionฤƒri generale Instalarea trebuie sฤƒ fie conformฤƒ reglementฤƒrilor locale ลŸi/sau naลฃionale. PinTherm Connect trebuie aลŸadar instalat de cฤƒtre un instalator competent ลŸi calificat, conform legislaลฃiei naลฃionale ลŸi internaลฃionale. În eventualitatea unei instalฤƒri, calibrฤƒri, modificฤƒri, întreลฃineri sau reparฤƒri incorecte, garanลฃia va fi anulatฤƒ. Opriti intotdeauna sursa de alimentare de 230 V inainte de a conecta terminalele. Tensiunea de alimentare din PinTherm Connect trebuie sa poata fi oprita intr-un mod dublu cu ajutorul unui intrerupฤƒtor permanent care este adecvat pentru 250VAC / 10A si respecta reglementarile de sigurantata aplicabile. Doar dispozitivele care respectฤƒ EN-IEC 61010-1 pot fi operate cu PinTherm Connect. Curatati carcasa PinTherm Connect cu o carpa umeda. Nu aplicati solventi. Nu exista cerinte privind ventilatia in imediata vecinatate a controlerului. Atentie - risc de electrocutare. ! Atentie - avertizare generala, risc de pericol. Pot exista tensiuni pe terminalele de conectare unde este amplasat a. ! 3.0 Detalii tehnice 3.1 Detalii tehnice PinTherm Connect • Nume tip : PinTherm Connect • Numฤƒr articol : 06 29 108 • Alimentare electricฤƒ : 90 – 240 VAC / 47-63Hz • Consum propriu : < 9W • Ceas : 24 ore cu schimbare automatฤƒ orฤƒ de varฤƒ/iarnฤƒ • Programe de comutare : 3 programe de comutare pe zi • Diferenta de comutare : 0,1 - 3K • Dimensiuni : 166 x 160 x 106mm (Lxlxî) • Greutate : 880 grame • Grad de protecลฃie : IP-54 • Mediu de instalare : Transport / depozitare: -20 ° C pana la + 70 ° C. Operational: -10 ° C pana la + 60 ° C Umiditatea relativa a aerului: 0-90% fara condensare Instalare maxima la 2000 metri deasupra nivelului marii. • Categorie de tensiune superioara : 11 • Nivel poluare : 2 • Schimbati contactul (contactele)* : Incalzire: 230Vac/16A (4A) Altele: 230Vac/10A (2,5A) • Setarea temperaturii : 0 pana la 39 ° C la 1 ° C reglabil 74 • • • • • • • Timer ore suplimentare Calibrarea Incalzire/Racire 0-10 VDC Senzor Opลฃiuni limbฤƒ Fuse : : : : : : : reglabil 1, 2 sau 3 ore (060, 120, 180) reglabil de la -3,5 ° C pana la + 3,5 ° C Contact reversibil pentru incalzire sau racire Iesire 0-10 VDC pentru incalzire sau racire Senzor extern de camera (06 29 086) NL/EN/DE/FR/PL/RO/LT 6A * Contactele releului sunt comutatoare functionale, nu intrerupatoare de siguranta. 3.2 Detalii tehnice pentru senzor extern de camera (optional) • Nume tip : RSTF NTC4,7K • Numฤƒr articol : 06 29 086 • Rezistenลฃฤƒ : NTC 4K7 • Dimensiuni : 79 x 81 x 26mm (Lxlxî) • Greutate : 46 grame • Racord electric : 0.75 -1.5mm² • Grad de protecลฃie : IP-30 RO 3.3 Tabel rezistenลฃฤƒ senzor glob extern -15°C -10°C -5°C 32.937kโ„ฆ 25.217kโ„ฆ 19.392kโ„ฆ 0°C 15.040kโ„ฆ 5°C 11.743kโ„ฆ 10°C 9.241kโ„ฆ 15°C 7.330kโ„ฆ 20°C 5.855kโ„ฆ 35°C 3.071kโ„ฆ 40°C 2.512kโ„ฆ 45°C 2.066kโ„ฆ 50°C 1.709kโ„ฆ 25°C 4.700kโ„ฆ 30°C 3.777kโ„ฆ 3.4 Setฤƒrile din fabricฤƒ pentru PinTherm Connect • Cod meniu : 1000 • Schimbarea orelor : MON, TUE, WED, THUR, FRI (LU, MA, MI, JOI, VI) orele 07:30-17:30 SAT, SUN (SÂM, DUM) orele 00:00-00:00 • Temperatura camerei : Temperaturฤƒ zi18°C Temperaturฤƒ noapte 08°C • Calibrare : +0.0 • Diferenta de comutare : 1K • Incalzire/Racire : Incalzire • 0-10V range : 1K • 0-10V min : 0V • 0-10V max : 10V • Modbus : Slave ID 001 • Setari IP : Static 75 4.0 Instalarea 4.1 Informaลฃii generale Înainte de a despacheta PinTherm Connect, verificaลฃi dacฤƒ nu este deteriorat, aparatul ลŸi senzorii furnizaลฃi împreunฤƒ cu acesta. Asiguraลฃi-vฤƒ cฤƒ tipul/modelul ลŸi voltajul sunt corecte. 4.2 Asamblarea PinTherm Connect Stabiliลฃi un loc corespunzฤƒtor pentru asamblarea PinTherm Connect. Montati PinTherm Connect pe o suprafata solida care poate suporta minim 4 kg. Este recomandabil ca PinTherm Connect sฤƒ fie plasat la o distanลฃฤƒ de ±1,5m de podea, intr-un loc bine accesibil. Pentru cablurile de etansare utilizati numai cabluri de etansare prevazute cu izolatie de tensiune, cu o clasa minima de incendiu UL94V2. Înainte de a efectua cablajul, verificaลฃi dacฤƒ alimentarea este opritฤƒ. În caz contrar, opriลฃi alimentarea înainte de a continua. Dacฤƒ alimentarea este opritฤƒ pentru aparatul care urmeazฤƒ a fi conectat, trebuie sฤƒ consultaลฃi manualul tehnic/de depanare al dispozitivului. Conectaลฃi PinTherm Connect conform uneia dintre schiลฃele electrice furnizate la finalul acestui manual tehnic. Pentru a selecta schema de cablaj corectฤƒ, trebuie sฤƒ cunoaลŸteลฃi tipul aparatului la care veลฃi conecta PinTherm Connect. Vezi de asemenea Anexa I pentru o selecลฃie. Atunci cand se aplica un semnal 0-10VDC, vezi tabelul de mai jos pentru a afla diametrul corect al cablului. Diametru 0.8mm2 1.0mm2 1.5mm2 Lungime 80 metri 100 metri 150 metri Este recomandatฤƒ folosirea unui cablu protejat. 4.3 Asamblarea senzorului glob extern Plasaลฃi senzorul glob extern într-un loc ferit de curent, lângฤƒ dispozitiv, la o înฤƒlลฃime de aprox. 1,5 m de podea ลŸi conectaลฃi senzorul la terminalele identificate în acest scop în PinTherm Connect. Vezi tabelul de mai jos pentru a afla diametrul corect al cablului. Diametru 0.8mm2 1.0mm2 1.5mm2 76 Lungime 80 metri 100 metri 150 metri Este recomandatฤƒ folosirea unui cablu protejat. 5.0 Manual depanare 5.1 Explicarea butoanelor ลŸi LED-urilor A PinTherm Connect 06.29.108 LU 08:01 18ºC ZI X:060 H B D F C 0 E I G M RESET I A B C D E F G H I J K L M N O - OK N ESC O J K RO L AfiลŸaj iluminat (vezi ลŸi 5.2) Buton pentru pornirea sau oprirea cฤƒldurii LED-ul se aprinde când funcลฃia de încฤƒlzire este pornitฤƒ Buton pentru pornirea sau oprirea poziลฃiei mare LED-ul se aprinde când funcลฃia este setatฤƒ pe mare Buton pentru deblocarea instalaลฃiei în eventualitatea unei erori (de arzฤƒtor de gaz) LED-ul se aprinde în eventualitatea unei erori (de arzฤƒtor de gaz) Buton pentru activarea meniului utilizatorului sau pentru comutarea la numฤƒrul urmฤƒtor Buton pentru confirmarea unei selecลฃii/modificฤƒri fฤƒcute sau pentru comutarea la urmฤƒtorul articol din meniu Buton pentru pฤƒrฤƒsirea meniului sau setare fฤƒrฤƒ a efectua vreo modificare Buton pentru pornirea sau oprirea temporizatorului pentru ore suplimentare Buton ๏€ต+๏€ถ­– pentru modificarea unei setฤƒri LED-ul se aprinde când cฤƒldura necesarฤƒ este în poziลฃia încฤƒlzire (arzฤƒtor de gaz pornit) LED-ul se aprinde de fiecare datฤƒ când dispozitivul funcลฃioneazฤƒ în poziลฃie mare LED-ul se aprinde când funcลฃia temporizator pentru ore suplimentare este pornitฤƒ 77 5.2 Explicarea afiลŸajului B A LU C 08:01 18ºC ZI X:060 D E A B C D E AfiลŸeazฤƒ ziua din sฤƒptฤƒmânฤƒ Aici este afiลŸatฤƒ ora exactฤƒ Indicฤƒ temperatura (°C) mฤƒsuratฤƒ Indicฤƒ numฤƒrul de minute înainte ca funcลฃia temporizator ore suplimentare sฤƒ fie opritฤƒ din nou, iar PinTherm Connect se ajusteazฤƒ la temperatura de noapte Indicฤƒ faptul cฤƒ PinTherm Connect este în poziลฃia zi (DAY) sau noapte (NIGHT) ลŸi este ajustat în funcลฃie de temperatura de zi sau de noapte 5.3 Operarea iniลฃialฤƒ a PinTherm Connect Când setaลฃi voltajul pentru PinTherm Connect pentru prima oarฤƒ, vi se va cere sฤƒ selectaลฃi limba necesarฤƒ, iar apoi setaลฃi ora ลŸi data. Apoi PinTherm Connect se va întoarce la ecranul principal. SELECT LANGUAGE ENGLISH OK SA 01-01-2006 00:00:00 selectati limba necesara merge la numarul semnalului luminos schimba numarul urmator LU Opลฃiuni limbฤƒ: NL, EN, DE, FR, PL, RO, LT 78 08:00 ZI 16°C OK 5.4 Activarea meniului utilizatorului LU 08:01 ZI 16°C OK CODUL 0000 OK merge la numarul semnalului luminos Cod meniu setare din fabrica 1000 schimba numarul urmator SETEAZA/SCHIMBA PROGRAMUL selectati meniul necesar ESC RO parasiti meniul si întoarceti-va la ecranul principal Puteลฃi schimba urmฤƒtoarele setฤƒri din meniu: – Introduce/schimbฤƒ orele – Schimbaลฃi temperaturฤƒ zi/noapte – Schimbaลฃi ora/data – Setari de vacanta – Schimbaลฃi codul de meniu – Schimbaลฃi limba – Calibrare – 0-10V min 0-5V – 0-10V max 5-10V – 0-10V range (1-3) – Modbus – Setari IP 5.5 Introducere/schimbare orฤƒ SETEAZA/SCHIMBA PROGRAMUL OK LUNI 1 07:30 -> 17:00 OK LUNI 2 --:-- -> --:-- OK merge la numarul semnalului luminos schimba numarul urmator LUNI 3 --:-- -> --:-merge la numarul semnalului luminos OK MARTI 1 07:30 -> 17:00 etc. DUMINICA 3 --:-- -> --:-- OK înapoi la meniu schimba numarul urmator 79 5.6 Schimbarea temperaturilor pentru zi/noapte selectati SETEAZA/SCHIMBA TEMPERATURA OK TEMP. ZIUA 18°C OK merge la numarul semnalului luminos schimba numarul urmator TEMP. NOAPTE 08°C OK merge la numarul meniu semnalului luminos înapoi la meniu schimba numarul urmator 5.7 Schimbarea orei ลŸi datei selectati MODIFICA ORA/DATA OK LU 23-03-2009 09:10:00 merge la numarul semnalului luminos OK înapoi la meniu schimba numarul urmator 5.8 Setari de vacanta In timpul blocului de timp stabilit, comanda se va regla in functie de temperatura de noapte. selectati SETARI VACANTA OK MOD VACANT ACTIV PORNI OK DE LA: 01-07-2017 LA: 01-08-2017 selectati sau dezactivati merge la numarul semnalului luminos schimba numarul urmator 5.9 Schimbaลฃi codul de meniu selectati MODIFICA CODUL OK SELECTATI COD 1000 merge la numarul semnalului luminos schimba numarul urmator noul cod de meniu 80 OK înapoi la meniu OK înapoi la meniu 5.10 Schimbare limbฤƒ selectati MODIFICA LIMBA SELECTATI LIMBA ROMAN OK selectati limba necesara OK înapoi la meniu Opลฃiuni limbฤƒ: NL, EN, DE, FR, PL, RO, LT. 5.11 Calibrare Dacฤƒ locul asamblฤƒrii nu este corespunzฤƒtor pentru senzorul extern, este posibil ca temperatura mฤƒsuratฤƒ de PinTherm Connect sฤƒ nu fie corectฤƒ. Aceastฤƒ diferenลฃฤƒ de temperaturฤƒ poate fi compensatฤƒ prin setarea unei valori de corecลฃie cu aceastฤƒ funcลฃie de calibrare. Exemplu: temperatura mฤƒsuratฤƒ este de 18°C, ecranul de pe PinTherm Connect indicฤƒ 20°C. AลŸadar diferenลฃa din acest exemplu este de 2°C mai mare - valoarea de corecลฃie trebuie sฤƒ fie aลŸadar setatฤƒ la -2°C. selectati CALIBREAZA TEMP CALIBREAZA TEMP + 0.0°C OK merge la numarul semnalului luminos OK înapoi la meniu schimba numarul urmator Valorea de corectie poate fi ajustata de la -3,5°C la +3,5°C 5.12 Incalzire/Racire selectati INCALZIRE/RACIRE OK INCALZIRE/RACIRE INCALZIRE schimbare setari OK înapoi la meniu Setarea pentru a face controlerul potrivit pentru controlul Incalzirii sau racirii. 81 RO 5.13 Diferenta de comutare selectati SCHIMBARE DIF. OK SCHIMBARE DIF. 1.0K OK înapoi la meniu merge la numarul meniu semnalului luminos Reglabil intre 0.1 si 3.0 K. 5.14 Schimbarea semnalului de control minim selectati 0-10V min(0-5V) 0-10V min(0-5V) 2.0 V OK schimbare setari OK înapoi la meniu Nota: Atunci cand nu exista nicio cerere de caldura, PinTherm Connect trimite un semnal de 0VDC. 5.15 Schimbarea semnalului de control maxim selectati 0-10V max(5-10V) OK 0-10V max(5-10V) 10.0 V schimbare setari OK înapoi la meniu 5.16 Schimbati intervalul de semnal de control Aceasta functie determina cand semnalul 0 - 10VDC este modulat inapoi in conditii de solicitare de caldura. Cand este setat la 1.0, PinTherm Connect va incepe sa moduleze semnalul 0-10V la 1K sub temperatura tinta. selectati 0-10V Range(1-3) OK 0-10V Range(1-3) 1.0 schimbare setari Intervalul poate fi setat intre 0.5 - 3.0 si este setat la 1.0 ca standard. ­­­ 82 OK înapoi la meniu 5.17 ModBus selectati SETARI MODBUS OK SETARI MODBUS 001 merge la numarul semnalului luminos OK înapoi la meniu schimba numarul urmator ID sclav: ajustabil 1 - 247 Setare de fabrica: 1 RO 5.18 Informatii Ethernet selectati INFORMATII ETHERNET OK ADRESA IP 192.168.001.100 OK ADRESA MAC 5410EC220037 OK înapoi la meniu Afisati adresa IP setata. 5.19 Setari IP selectati SETARI IP OK MOD IP STATIC OK schimbare setari ADRESA IP 192.168.001.100 MASCA SUBNET 255.255.255.000 merge la numarul meniu semnalului luminos merge la numarul meniu semnalului luminos schimba numarul urmator schimba numarul urmator OK înapoi la meniu DHCP - adresa IP de atribuire automata Static - setati adresa IP fixa Masca SUBnet 5.20 Pornire/oprire timp suplimentar Cu aceastฤƒ funcลฃie, este posibil sฤƒ comutaลฃi manual 1, 2 sau 3 ore la temperatura pe timp de zi în afara timpilor de schimbare setaลฃi. LED-ul galben cu simbolul se va aprinde, indicând faptul cฤƒ funcลฃia este pornitฤƒ. Va fi de asemenea indicat pe afiลŸajul de sub timpul rฤƒmas în minute înainte ca funcลฃia sฤƒ se dezactiveze din nou, iar PinTherm Connect va opera din nou la temperaturฤƒ pe timp de noapte. Între timp, funcลฃia poate fi de asemenea dezactivatฤƒ din nou apฤƒsând butonul pânฤƒ când LED-ul galben se stinge, iar numฤƒrul de minute nu mai este indicat pe afiลŸaj. 83 Vezi imaginea de mai jos. LU 17:01 18°C NOAPTE LU 17:01 18°C ZI X:060 LU 17:01 18°C ZI X:120 LU 17:01 18°C ZI X:180 5.21 Porniti functia de stergere a cosului de fum Puteti utiliza aceasta functie pentru a comuta temporar aparatul la iesirea termica completa / iesirea partiala a caldurii astfel incat sa se poata efectua masuratori. Consultati informatiile de mai jos pentru instructiuni despre cum sa activati sau sa dezactivati aceasta functie. Dupa activare, aceasta functie ramane activa timp de 15 minute si se va opri automat dupa aceasta perioada. 0-10V 0 Tineti apasat timp de +/- 12 secunde 10V 14:59 Folositi butoanele de mai jos pentru ca aparatul sa functioneze la o tensiune mai mica (reduceti puterea de caldura) apasati pentru a creste tensiunea (maxim 10V) apasati pentru a reduce tensiunea ESC Aceasta opreste functia si va duce inapoi la ecranul principal 5.22 Setฤƒrile din fabricฤƒ pentru PinTherm Connect Dacฤƒ folosiลฃi aceastฤƒ funcลฃie, toate setฤƒrile din fabricฤƒ vor fi re-setate. Aceastฤƒ funcลฃie poate fi activatฤƒ oricând. Vezi imaginea de mai jos. OK tineti apasat timp de ± 12 secunde REVENITI LA IMPLICITE OK SETARI IMPLICITE SETATE! SELECT LANGUAGE ENGLISH ESC prin eceasta, va întoarceti la principal. Lar valorile din fabrica nu vor fi re-setate! LU 08:01 ZI 16°C 6.0 Aruncarea PinTherm Connect De fiecare datฤƒ când PinTherm Connect este înlocuit sau îndepฤƒrtat, trebuie reciclat sau casat conform reglementฤƒrilor naลฃionale ลŸi/sau locale în vigoare. 7.0 Modbus - Comunicare [12] - Lista Modbus [13] 84 8.0 Posibilitฤƒลฃi de cablaj pentru PinTherm Connect PinTherm Connect 06.29.108 LU 08:01 ZI 18ºC X:060 0 I RESET OK RO ESC L N Terminale de conectare (230Vac/50Hz) 21 - 22 Ventilatie continua 21 - 23 Incalzire/Racire 24 - 25 Semnal de defectiune 25 - 26 Resetare + - 0-10Vdc (Incalzire/Racire) 11 - 12 Senzor extern de camera A - B MODBUS RTU (R ground) RJ 45 connector Internet / Modbus TCP/IP 13 - 14 Contact ventilator extern Atentie: Tensiune periculoasa prezenta la N, L, 13, 14, 21, 22, 23, 24, 25 ลŸi 26 Cu PinTherm Connect, pot fi controlate numai dispozitivele care respecta normele de siguranta prevazute în EN-IEC 61010-1. 85 EN Select the right drawing! Drawing Page DE Der richtigen schaltplan Wählen! Schaltplan Seite FR Choisir schema electrique! Schematique Page NL Kies het juiste elektrische schema! Schema Pagina PL Wybierz schemat Schemat Strona RO Selectati schema corecta! Schema Pagina GS+ [1] 87 GSX [2] FÖHN [3] 88 [4] TANNER MDA 230V PinTherm Connect 06.29.108 MON 08:01 DAY 18ºC X:060 [5] 89 0 I RESET OK TANNER MDA EC [6] ECOFAN W42/W82/W142 [7] ESC 06 29 108 90 ECOFAN W42/W82/W142 EC [8] MDV BLUE EC 230V [9] 91 MDV BLUE EC 400V [10] 92 [11] 93 4x 86 ๏€ ๏€‚ [1] ๏€ƒ ๏€„ ๏€… ๏€† ๏€‡ ๏€ˆ ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€–๏€•๏€๏€๏€๏€–๏€—๏€“๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€‚๏€๏€‰ ๏€‰ ๏€Š ๏€‚๏€ ๏€‚๏€‚ ๏€‚๏€ƒ ๏€‚๏€„ ๏€‚๏€… ๏€‚๏€† ๏€‚๏€‡ ๏€‚๏€ˆ ๏€‚๏€‰ ๏€‚ ๏€‚๏€† ๏€‚๏€‡ ๏€‚๏€ˆ ๏€‚๏€‰ ๏€‚ ๏€˜๏€ฅ๏€ฏ ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€”๏€•๏€๏€๏€๏€–๏€—๏€“๏€“๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€‚๏€๏€‰ ๏€ ๏€ญ ๏€ฏ ๏€ค ๏€‚๏€‚ ๏€‚๏€ƒ ๏€ฃ ๏€ฐ ๏€ƒ๏€‚ ๏€ƒ๏€„ ๏€ƒ๏€ƒ ๏€ƒ๏€… ๏€ƒ๏€† ๏€ƒ๏€‡ ๏€‚๏€„ ๏€‚๏€… ๏€›๏€•๏€น๏€ฎ๏€ข๏€จ ๏€‚ ๏€ญ๏€ธ ๏€ƒ ๏€‚ ๏€ƒ ๏€ผ๏€‚ ๏€‡๏€ ๏€ฃ๏€Ž๏€”๏€“๏€…๏€ถ๏€ˆ๏€ท ๏€Ž๏€”๏€‹๏€ณ๏€บ๏€‹ ๏€ฎ ๏€Ž๏€Ž ๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€๏€‰๏€‡ ๏„๏€„ ๏€‚ ๏€‹๏€ฒ ๏€ฃ ๏€ฐ๏€‚ ๏€‚๏€ต๏€ƒ๏€„๏€๏€ž๏€“๏€ฏ๏€“๏€‹๏€ฒ๏€ณ๏€†๏€๏€ช๏€ซ ๏„๏€‚ ๏€ƒ ๏€‚ ๏€ƒ ๏€„ ๏€… ๏€† ๏€‡ ๏€ˆ ๏€‰ ๏€ฐ ๏€ฃ ๏€‹๏€ฒ ๏„๏€„ ๏€… ๏€บ๏€ฃ๏€Ž๏€ฒ๏€ญ๏€ผ๏€๏€”๏€ฒ๏€ฏ ๏€›๏๏€œ๏€ด๏€ฐ๏€ฒ ๏€† ๏€”๏๏€ฃ๏€ฃ๏€ฒ๏€”๏€Ž๏€บ๏๏€ฃ๏€“๏€ฎ๏๏„๏€“๏€˜๏€ฅ๏€ฏ๏€ณ๏€˜๏€ฅ๏„๏€“๏€„๏€๏€™๏€๏€…๏€™๏€…๏€†๏€ ๏€„ ๏€ [2] ๏€‚ ๏€ƒ ๏€„ ๏€… ๏€˜๏€ฅ๏€ฏ ๏€… ๏€† ๏€‡ ๏€ˆ ๏€ค ๏€ฒ๏€ธ๏€—๏€๏€‘๏€๏€๏€“๏€‘๏€ข๏€Œ๏€’๏€—๏€๏€ก๏€•๏€๏€ฆ๏€๏€‘ ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€–๏€•๏€๏€๏€๏€–๏€—๏€“๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€‚๏€๏€‰ ๏€ค ๏€ ๏€๏€‘๏€ป๏€จ๏€–๏€๏€š๏€ป๏€๏€ฆ๏€š๏€š๏€‘ ๏€ผ๏€‚ ๏€ค ๏€ฑ๏€๏€ป๏€๏€‘๏€Œ๏€๏€ฌ ๏€ ๏€Ž๏€”๏€‹๏€ณ๏€บ๏€‹ ๏€Š ๏€‚๏€ ๏€‚๏€‚ ๏€‚๏€ƒ ๏€‚๏€„ ๏€‚๏€… ๏€Ž๏€ช๏€ค๏€๏€‡๏€ƒ๏€Š๏€‚๏€๏€‰ ๏€ณ๏€ณ ๏€…๏€‚ ๏€ณ๏€ณ ๏€‚๏€™๏€ ๏€˜๏€ฅ๏„ ๏€Ž๏€Ž ๏€ ๏€ฅ ๏€‰ ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€”๏€•๏€๏€๏€๏€–๏€—๏€“๏€“๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€‚๏€๏€‰ ๏€ฎ ๏€ญ ๏€ฏ ๏€ค ๏€‚๏€‚ ๏€‚๏€ƒ ๏€ฃ ๏€ฐ ๏€ƒ๏€‚ ๏€ƒ๏€„ ๏€ƒ๏€ƒ ๏€ƒ๏€… ๏€ƒ๏€† ๏€ƒ๏€‡ ๏€‚๏€„ ๏€‚๏€… ๏€›๏€•๏€น๏€ฎ๏€ข๏€จ ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€”๏€•๏€๏€๏€๏€–๏€— ๏€ญ ๏€Œ๏€“๏€๏€“๏€๏€“๏€•๏€“๏€ก๏€“๏€š๏€“๏€—๏€“๏€Œ๏€“๏€ก๏€“๏€๏€“๏€ช๏€“๏€š๏€“๏€ฆ๏€“๏€ฆ๏€“๏€๏€“๏€๏€“๏€๏€“๏€๏€“๏€Œ๏€“๏€ซ๏€“๏€ข๏€“๏€๏€“๏€ฌ ๏€ƒ ๏€‚ ๏€ƒ ๏€Ž๏€Ž ๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€๏€‰๏€‡ ๏„๏€„ ๏€‚ ๏€Ÿ๏€™๏€ ๏€™ ๏€œ๏€š๏€—๏€ข๏€’ ๏€˜๏€๏€–๏€™ ๏€Ž๏€ก๏€œ ๏€ฃ๏€•๏€‘๏€’ ๏€‹๏€ฒ ๏€ฃ ๏€Ž๏€ช๏€ค๏€๏€‡๏€ƒ๏€Š๏€‚๏€๏€‰ ๏€Ž๏€๏€๏€‘๏€’๏€•๏€จ๏€—๏€š๏€—๏€จ ๏€๏€‘๏€—๏€™๏€๏€‘ ๏€Ž๏€ฉ๏€ง๏€ ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’ ๏€ž๏€๏€‘๏€จ๏€Œ๏€•๏€ ๏€‚๏€™๏€ ๏€ฐ๏€‚ ๏„๏€‚ ๏€ƒ ๏€… ๏€˜๏€‘๏€ข๏€ง๏€ง๏€ ๏€‚๏€ต๏€ƒ๏€„๏€๏€ž๏€“๏€ฏ๏€“๏€‹๏€ฒ๏€ณ๏€†๏€๏€ช๏€ซ ๏€‚ ๏€ƒ ๏€„ ๏€… ๏€† ๏€‡ ๏€ˆ ๏€‰ ๏€ฐ ๏€ฃ ๏€‹๏€ฒ ๏„๏€„ ๏€‚๏€ค๏€†๏€ค๏€ƒ๏€๏€‚๏€‰ ๏€ผ๏€‚ ๏€‡๏€ ๏€ฃ๏€Ž๏€”๏€“๏€…๏€ถ๏€ˆ๏€ท ๏€‚ ๏€ญ๏€ธ ๏€ฅ๏€–๏€๏€š๏€ฆ๏€—๏€ง๏€ฆ๏€š๏€๏€ค ๏€๏€ข๏€’๏€’๏€๏€‘ ๏€˜๏€ฅ๏€ฏ ๏€˜๏€๏€—๏€™ ๏€บ๏€ฃ๏€Ž๏€ฒ๏€ญ๏€ผ๏€๏€”๏€ฒ๏€ฏ ๏€›๏๏€œ๏€ด๏€ฐ๏€ฒ ๏€† ๏€”๏๏€ฃ๏€ฃ๏€ฒ๏€”๏€Ž๏€บ๏๏€ฃ๏€“๏€ฎ๏๏„๏€“๏€˜๏€ฅ๏€ฏ๏€ณ๏€˜๏€ฅ๏„๏€“๏€„๏€๏€™๏€๏€…๏€™๏€…๏€†๏€ ๏€’๏€š๏€ธ๏€™๏€“๏€‰๏€“๏€˜๏€ฅ๏„ ๏€„ ๏€… ๏€† ๏€‡ ๏€˜๏€ฅ๏„ ๏€Ž๏€Ž ๏€ค DE๏€ผ๏€‚ ๏€ค EN๏€ ๏€ฅ FR NL PL ๏€ค ๏€… ๏€† ๏€‡ ๏€˜๏€ฅ๏„ ๏€Ž๏€ช๏€ค๏€๏€‡๏€ƒ๏€Š๏€‚๏€๏€‰ ๏€ณ๏€ณ ๏€…๏€ ๏€ณ๏€ณ ๏€‚๏€™๏€ WS TT F1 ๏€ฒ๏€ธ๏€—๏€๏€‘๏€๏€๏€“๏€‘๏€ข๏€Œ๏€’๏€—๏€๏€ก๏€•๏€๏€ฆ๏€๏€‘ Isolator switch Black bulb sensor Fuse ๏€ ๏€๏€‘๏€ป๏€จ๏€–๏€๏€š๏€ป๏€๏€ฆ๏€š๏€š๏€‘ ๏€ฑ๏€๏€ป๏€๏€‘๏€Œ๏€๏€ฌ Reparatur schalter Schwarze kugel fühler Sicherung L’interrupteur de proximité Capteur globe noir Fusible Werkschakelaar Zwarte bol voeler Zekering ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€”๏€•๏€๏€๏€๏€–๏€— ๏€˜๏€ฅ๏„ Wyล‚acznik serwisowy Czujnik Czarna kula Bezpiecznik Switch pentru izolare Senzor glob Fitil ๏€ฅ๏€–๏€๏€š๏€ฆ๏€—๏€ง๏€ฆ๏€š๏€๏€ค ๏€๏€ข๏€’๏€’๏€๏€‘ ๏€ญ ๏€Œ๏€“๏€๏€“๏€๏€“๏€•๏€“๏€ก๏€“๏€š๏€“๏€—๏€“๏€Œ๏€“๏€ก๏€“๏€๏€“๏€ช๏€“๏€š๏€“๏€ฆ๏€“๏€ฆ๏€“๏€๏€“๏€๏€“๏€๏€“๏€๏€“๏€Œ๏€“๏€ซ๏€“๏€ข๏€“๏€๏€“๏€ฌ RO ๏€„ ๏€˜๏€๏€—๏€™ ๏€Ÿ๏€™๏€ ๏€™ ๏€œ๏€š๏€—๏€ข๏€’ ๏€˜๏€๏€–๏€™ ๏€Ž๏€ก๏€œ ๏€ฃ๏€•๏€‘๏€’ ๏€‚๏€ค๏€†๏€ค๏€ƒ๏€๏€‚๏€‰ ๏€˜๏€‘๏€ข๏€ง๏€ง๏€ ๏€Ž๏€ช๏€ค๏€๏€‡๏€ƒ๏€Š๏€‚๏€๏€‰ ๏€Ž๏€๏€๏€‘๏€’๏€•๏€จ๏€—๏€š๏€—๏€จ ๏€๏€‘๏€—๏€™๏€๏€‘ 87 ๏€Ž๏€ฉ๏€ง๏€ ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’ ๏€ž๏€๏€‘๏€จ๏€Œ๏€•๏€ ๏€‚๏€™๏€ ๏€ [3] ๏€‚ ๏€ƒ ๏€„ ๏€… ๏€† ๏€‡ ๏€ˆ ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€–๏€•๏€๏€๏€๏€–๏€—๏€“๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€‚๏€๏€‰ ๏€‰ ๏€Š ๏€‚๏€ ๏€‚๏€‚ ๏€‚๏€ƒ ๏€‚๏€„ ๏€‚๏€… ๏€‚๏€† ๏€‚๏€‡ ๏€‚๏€ˆ ๏€‚๏€‰ ๏€‚๏€„ ๏€‚๏€… ๏€‚๏€† ๏€‚๏€‡ ๏€‚๏€ˆ ๏€‚๏€‰ ๏€ผ๏ƒ๏€ช๏€ฃ ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€”๏€•๏€๏€๏€๏€–๏€—๏€“๏€“๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€‚๏€๏€‰ ๏€ ๏€ญ ๏€ฏ ๏€ค ๏€‚๏€‚ ๏€‚๏€ƒ ๏€ฃ ๏€ฐ ๏€ƒ๏€‚ ๏€ƒ๏€„ ๏€ƒ๏€ƒ ๏€ƒ๏€… ๏€ƒ๏€† ๏€ƒ๏€‡ ๏€‚๏€„ ๏€‚๏€… ๏€›๏€•๏€น๏€ฎ๏€ข๏€จ ๏€‚ ๏€ญ๏€ธ ๏€ƒ ๏€‚ ๏€ƒ ๏€ฃ๏€Ž๏€”๏€“๏€…๏€ถ๏€ˆ๏€ท ๏€Ž๏€”๏€‹๏€ณ๏€บ๏€‹ ๏€ฎ ๏„๏€ƒ ๏€Ž๏€Ž ๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€๏€‰๏€‡ ๏€‚ ๏€ƒ ๏€„ ๏€… ๏€† ๏€‚ ๏€‡ ๏€ ๏€ƒ ๏€‚ ๏€ƒ ๏€ผ๏ƒ๏€ช๏€ฃ ๏€ [4] ๏€‚ ๏€ƒ ๏€„ ๏€… ๏€† ๏€‡ ๏€ˆ ๏€ค ๏€ฒ๏€ธ๏€—๏€๏€‘๏€๏€๏€“๏€‘๏€ข๏€Œ๏€’๏€—๏€๏€ก๏€•๏€๏€ฆ๏€๏€‘ ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€–๏€•๏€๏€๏€๏€–๏€—๏€“๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€‚๏€๏€‰ ๏€‰ ๏€Š ๏€‚๏€ ๏€‚๏€‚ ๏€‚๏€ƒ ๏€Ž๏€ช๏€ค๏€๏€‡๏€ƒ๏€Š๏€‚๏€๏€‰ ๏€ณ๏€ณ ๏€„๏€ ๏€ณ๏€ณ ๏€‚๏€™๏€ ๏€Ž๏€๏€ฃ๏€ฃ๏€ฒ๏€ญ๏€“๏€›๏€œ๏€๏€“๏€ƒ๏€„๏€๏€ž ๏€Ž๏€Ž ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€”๏€•๏€๏€๏€๏€–๏€—๏€“๏€“๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€‚๏€๏€‰ ๏€ ๏€Ž๏€”๏€‹๏€ณ๏€บ๏€‹ ๏€ฎ ๏€ญ ๏€ฏ ๏€ค ๏€‚๏€‚ ๏€‚๏€ƒ ๏€ฃ ๏€ฐ ๏€ƒ๏€‚ ๏€ƒ๏€ƒ ๏€ƒ๏€„ ๏€ƒ๏€… ๏€ƒ๏€† ๏€ƒ๏€‡ ๏€‚๏€„ ๏€‚๏€… ๏€›๏€•๏€น๏€ฎ๏€ข๏€จ ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€”๏€•๏€๏€๏€๏€–๏€— ๏€ญ ๏€Œ๏€“๏€๏€“๏€๏€“๏€•๏€“๏€ก๏€“๏€š๏€“๏€—๏€“๏€Œ๏€“๏€ก๏€“๏€๏€“๏€ช๏€“๏€š๏€“๏€ฆ๏€“๏€ฆ๏€“๏€๏€“๏€๏€“๏€๏€“๏€๏€“๏€Œ๏€“๏€ซ๏€“๏€ข๏€“๏€๏€“๏€ฌ ๏€‹๏€ฒ ๏€ฃ ๏€ฐ๏€‚ ๏€… ๏€ด๏€ƒ ๏€ด๏€‚ ๏€Ž๏€ฎ ๏€œ๏€š๏€—๏€ข๏€’ ๏€˜๏€๏€–๏€™ ๏€Ž๏€ก๏€œ ๏€ฃ๏€•๏€‘๏€’ ๏€‚๏€ค๏€†๏€ค๏€ƒ๏€๏€‚๏€‰ ๏€˜๏€‘๏€ข๏€ง๏€ง๏€ ๏€Ž๏€ช๏€ค๏€๏€‡๏€ƒ๏€Š๏€‚๏€๏€‰ ๏€Ž๏€๏€๏€‘๏€’๏€•๏€จ๏€—๏€š๏€—๏€จ ๏€๏€‘๏€—๏€™๏€๏€‘ ๏€Ž๏€ฉ๏€ง๏€ ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’ ๏€ž๏€๏€‘๏€จ๏€Œ๏€•๏€ ๏€‚๏€™๏€ ๏€‹๏€ฒ ๏€‚๏€ต๏€ƒ๏€„๏€๏€ž๏€“๏€ฏ๏€“๏€‹๏€ฒ๏€ณ๏€†๏€๏€ช๏€ซ ๏€Ž๏€๏€ฃ๏€ฃ๏€ฒ๏€ญ๏€“๏€›๏€œ๏€ ๏€๏€‚ ๏€ƒ๏€…๏€ž๏€ณ๏€ƒ๏€„๏€๏€ž ๏€ฑ๏€  ๏€ฑ๏€ƒ ๏€„ ๏€ƒ ๏€Ÿ๏€™๏€ ๏€™ ๏€˜๏€ฒ๏€ณ๏€˜๏€ญ ๏€Ž๏€Ž ๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€๏€‰๏€‡ ๏€ผ๏€‚ ๏€‡๏€ ๏€ฎ๏€ญ ๏€ƒ ๏€ฃ๏€Ž๏€”๏€“๏€…๏€ถ๏€ˆ๏€ท ๏€ญ๏€ธ ๏€‚ ๏€ƒ ๏€‚ ๏€ฎ๏€ฐ ๏€ ๏€ฅ ๏€‚ ๏€ฅ๏€–๏€๏€š๏€ฆ๏€—๏€ง๏€ฆ๏€š๏€๏€ค ๏€๏€ข๏€’๏€’๏€๏€‘ ๏€ผ๏ƒ๏€ช๏€ฃ ๏€˜๏€๏€—๏€™ ๏€ฐ ๏€ฃ ๏€Ž๏€ช๏€ค๏€๏€‡๏€ƒ๏€Š๏€‚๏€๏€‰ ๏€ณ๏€ณ ๏€‚๏€ ๏€ณ๏€ณ ๏€‚๏€™๏€ WS๏€Ž๏€Ž ๏€ค ๏€ฒ๏€ธ๏€—๏€๏€‘๏€๏€๏€“๏€‘๏€ข๏€Œ๏€’๏€—๏€๏€ก๏€•๏€๏€ฆ๏€๏€‘ ๏€ ๏€ฅ ๏€ค ๏€ ๏€๏€‘๏€ป๏€จ๏€–๏€๏€š๏€ป๏€๏€ฆ๏€š๏€š๏€‘ Isolator switch ๏€ผ๏€‚ ๏€ค ๏€ฑ๏€๏€ป๏€๏€‘๏€Œ๏€๏€ฌ Reparatur schalter ๏€๏€‚ ๏€ค ๏€„๏€ค๏€ฝ๏€๏€ฌ๏€ป๏€ฆ๏€๏€ง๏€“๏€พ๏€•๏€ง๏€—๏€Œ๏€•๏€๏€๏€๏€ฆ๏€ฟ๏€“ L’interrupteur de proximité Werkschakelaar Wyล‚acznik serwisowy Switch pentru izolare EN DE FR NL ๏€ญ PL ๏€Œ๏€“๏€๏€“๏€๏€“๏€•๏€“๏€ก๏€“๏€š๏€“๏€—๏€“๏€Œ๏€“๏€ก๏€“๏€๏€“๏€ช๏€“๏€š๏€“๏€ฆ๏€“๏€ฆ๏€“๏€๏€“๏€๏€“๏€๏€“๏€๏€“๏€Œ๏€“๏€ซ๏€“๏€ข๏€“๏€๏€“๏€ฌ RO 88 TT Black bulb sensor Schwarze kugel fühler Capteur globe noir Zwarte bol voeler ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€”๏€•๏€๏€๏€๏€–๏€— Czujnik Czarna kula Senzor glob F1 Fuse Sicherung Fusible Zekering Bezpiecznik Fitil Y1 3-way valve (optional) 3-wege ventil (optional) 3-voies vanne (optional) 3-wegklep (optioneel) ๏€Ž๏€š๏€๏€๏€๏€‘๏€“๏€›๏€œ๏€๏€“๏€ƒ๏€„๏€๏€ž Zawór 3-drogowy (Opcja) Supapฤƒ cutrei cฤƒi (Optional) ๏€ฅ๏€–๏€๏€š๏€ฆ๏€—๏€ง๏€ฆ๏€š๏€๏€ค ๏€๏€ข๏€’๏€’๏€๏€‘ ๏€˜๏€๏€—๏€™ ๏€Ÿ๏€™๏€ ๏€™ ๏€œ๏€š๏€—๏€ข๏€’ ๏€˜๏€๏€–๏€™ ๏€Ž๏€ก๏€œ ๏€ฃ๏€•๏€‘๏€’ ๏€‚๏€ค๏€†๏€ค๏€ƒ๏€๏€‚๏€‰ ๏€˜๏€‘๏€ข๏€ง๏€ง๏€ ๏€๏€‘๏€—๏€™๏€๏€‘ ๏€Ž๏€ช๏€ค๏€๏€‡๏€ƒ๏€Š๏€‚๏€๏€‰ ๏€Ž๏€๏€๏€‘๏€’๏€•๏€จ๏€—๏€š๏€—๏€จ ๏€Ž๏€ฉ๏€ง๏€ ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’ ๏€ž๏€๏€‘๏€จ๏€Œ๏€•๏€ ๏€‚๏€™๏€ ๏€ [5] ๏€‚ ๏€ƒ ๏€„ ๏€… ๏€† ๏€‡ ๏€ˆ ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€–๏€•๏€๏€๏€๏€–๏€—๏€“๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€‚๏€๏€‰ ๏€‰ ๏€Š ๏€‚๏€ ๏€‚๏€‚ ๏€‚๏€ƒ ๏€‚๏€„ ๏€‚๏€… ๏€‚๏€† ๏€‚๏€‡ ๏€‚๏€ˆ ๏€‚๏€‰ ๏€‚๏€† ๏€‚๏€‡ ๏€‚๏€ˆ ๏€‚๏€‰ ๏€Ž๏€๏€ฃ๏€ฃ๏€ฒ๏€ญ๏€“๏€›๏€œ๏€๏€“๏€ƒ๏€„๏€๏€ž ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€”๏€•๏€๏€๏€๏€–๏€—๏€“๏€“๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€‚๏€๏€‰ ๏€ ๏€ญ ๏€ฏ ๏€ค ๏€‚๏€‚ ๏€‚๏€ƒ ๏€ฃ ๏€ฐ ๏€ƒ๏€‚ ๏€ƒ๏€ƒ ๏€ƒ๏€„ ๏€ƒ๏€… ๏€‚ ๏€„ ๏€ƒ ๏€… ๏€ด๏€ƒ ๏€ด๏€‚ ๏€‹๏€ฒ ๏€ฃ ๏€ฐ๏€‚ ๏€Ž๏€ฎ ๏€… ๏€ด๏€ƒ ๏€ด๏€‚ ๏€ฎ๏€ฐ ๏€„ ๏€ƒ ๏€Ž๏€ฎ ๏€‹๏€ฒ ๏€Ž๏€๏€ฃ๏€ฃ๏€ฒ๏€ญ๏€“๏€›๏€œ๏€ ๏€Ž๏€๏€ฃ๏€ฃ๏€ฒ๏€ญ๏€“๏€›๏€œ๏€ ๏€ฐ ๏€ฃ ๏€ƒ ๏€„ ๏€… ๏€† ๏€‡ ๏€ˆ ๏€ค ๏€ฒ๏€ธ๏€—๏€๏€‘๏€๏€๏€“๏€‘๏€ข๏€Œ๏€’๏€—๏€๏€ก๏€•๏€๏€ฆ๏€๏€‘ ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€–๏€•๏€๏€๏€๏€–๏€—๏€“๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€‚๏€๏€‰ ๏€ ๏€ฅ ๏€ค ๏€ ๏€๏€‘๏€ป๏€จ๏€–๏€๏€š๏€ป๏€๏€ฆ๏€š๏€š๏€‘ ๏€ผ๏€‚ ๏€ค ๏€ฑ๏€๏€ป๏€๏€‘๏€Œ๏€๏€ฌ ๏€๏€‚ ๏€ค ๏€„๏€ค๏€ฝ๏€๏€ฌ๏€ป๏€ฆ๏€๏€ง๏€“๏€พ๏€•๏€ง๏€—๏€Œ๏€•๏€๏€๏€๏€ฆ๏€ฟ๏€“ ๏€ ๏€ฎ ๏€ญ ๏€ฏ ๏€‰ ๏€Š ๏€‚๏€ ๏€‚๏€‚ ๏€‚๏€ƒ ๏€‚๏€„ ๏€‚๏€… ๏€Ž๏€ช๏€ค๏€๏€‡๏€ƒ๏€Š๏€‚๏€๏€‰ ๏€ณ๏€ณ ๏€‚๏€‚ ๏€ณ๏€ณ ๏€‚๏€™๏€ ๏€Ž๏€๏€ฃ๏€ฃ๏€ฒ๏€ญ๏€“๏€›๏€œ๏€๏€“๏€พ๏€ฒ๏€”๏€ค๏€ผ๏€๏€ฃ๏€ฟ ๏€Ž๏€Ž ๏€Ž๏€”๏€‹๏€ณ๏€บ๏€‹ ๏€ฑ๏€ƒ ๏€‚ ๏€‚๏€ต๏€ƒ๏€„๏€๏€ž๏€“๏€ฏ๏€“๏€‹๏€ฒ๏€ณ๏€†๏€๏€ช๏€ซ ๏€๏€‚ ๏€ƒ๏€…๏€ž๏€ณ๏€ƒ๏€„๏€๏€ž ๏€‹๏€ฒ ๏€ฑ๏€  ๏€ฑ๏€ƒ ๏€ ๏€ฅ ๏€˜๏€ฒ๏€ณ๏€˜๏€ญ ๏€Ž๏€Ž ๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€๏€‰๏€‡ [6] ๏€‚๏€… ๏€ฎ๏€ญ ๏€ผ๏€‚ ๏€‡๏€ ๏€ฑ๏€  ๏€ƒ ๏€ฎ๏€ญ ๏€ญ๏€ธ ๏€‚ ๏€ƒ ๏€ฃ๏€Ž๏€”๏€“๏€…๏€ถ๏€ˆ๏€ท ๏€‚ ๏€‚ ๏€‚๏€„ ๏€ƒ๏€‡ ๏€˜๏€ฒ๏€ณ๏€˜๏€ญ ๏€ ๏€ฅ ๏€ ๏€ƒ๏€† ๏€›๏€•๏€น๏€ฎ๏€ข๏€จ ๏€ฎ๏€ฐ ๏€Ž๏€”๏€‹๏€ณ๏€บ๏€‹ ๏€ฎ ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€”๏€•๏€๏€๏€๏€–๏€—๏€“๏€“๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€‚๏€๏€‰ ๏€ค ๏€‚๏€‚ ๏€‚๏€ƒ ๏€ฃ ๏€ฐ ๏€ƒ๏€‚ ๏€ƒ๏€„ ๏€ƒ๏€ƒ ๏€ƒ๏€… ๏€ƒ๏€† ๏€ƒ๏€‡ ๏€‚๏€„ ๏€‚๏€… ๏€›๏€•๏€น๏€ฎ๏€ข๏€จ ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€”๏€•๏€๏€๏€๏€–๏€— ๏€ญ ๏€ฅ๏€–๏€๏€š๏€ฆ๏€—๏€ง๏€ฆ๏€š๏€๏€ค ๏€๏€ข๏€’๏€’๏€๏€‘ ๏€Ž๏€š๏€๏€๏€๏€‘๏€“๏€›๏€œ๏€๏€“๏€ƒ๏€„๏€๏€ž ๏€Œ๏€“๏€๏€“๏€๏€“๏€•๏€“๏€ก๏€“๏€š๏€“๏€—๏€“๏€Œ๏€“๏€ก๏€“๏€๏€“๏€ช๏€“๏€š๏€“๏€ฆ๏€“๏€ฆ๏€“๏€๏€“๏€๏€“๏€๏€“๏€๏€“๏€Œ๏€“๏€ซ๏€“๏€ข๏€“๏€๏€“๏€ฌ ๏€˜๏€๏€—๏€™ ๏€Ÿ๏€™๏€ ๏€™ ๏€œ๏€š๏€—๏€ข๏€’ ๏€˜๏€๏€–๏€™ ๏€Ž๏€ก๏€œ ๏€ฃ๏€•๏€‘๏€’ ๏€‚๏€ค๏€†๏€ค๏€ƒ๏€๏€‚๏€‰ ๏€˜๏€‘๏€ข๏€ง๏€ง๏€ ๏€Ž๏€ช๏€ค๏€๏€‡๏€ƒ๏€Š๏€‚๏€๏€‰ ๏€Ž๏€๏€๏€‘๏€’๏€•๏€จ๏€—๏€š๏€—๏€จ ๏€๏€‘๏€—๏€™๏€๏€‘ ๏€Ž๏€ฉ๏€ง๏€ ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’ ๏€ž๏€๏€‘๏€จ๏€Œ๏€•๏€ ๏€‚๏€™๏€ ๏€๏€‚ ๏€‚ ๏€ƒ ๏€ƒ ๏€Ž๏€Ž ๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€๏€‰๏€‡ ๏€ผ๏€‚ ๏€‡๏€ ๏€ฃ๏€Ž๏€”๏€“๏€…๏€ถ๏€ˆ๏€ท ๏€‚ ๏€ญ๏€ธ ๏€‹๏€ฒ ๏€ฃ ๏€ฐ๏€‚ ๏€‚๏€ต๏€ƒ๏€„๏€๏€ž๏€“๏€ฏ๏€“๏€‹๏€ฒ๏€ณ๏€†๏€๏€ช๏€ซ ๏€ ๏€ฅ ๏€๏€ค๏€‚๏€๏€ž ๏€˜๏€ฃ๏€œ ๏€‚ ๏€„ ๏€ƒ ๏€… ๏€ฐ๏€‚ ๏€ฃ ๏€‹๏€ฒ ๏€Ž๏€๏€ฃ๏€ฃ๏€ฒ๏€ญ๏€“๏€›๏€œ๏€๏€“๏€ฒ๏€” ๏€Ž๏€ช๏€ค๏€๏€‡๏€ƒ๏€Š๏€‚๏€๏€‰ ๏€ณ๏€ณ ๏€‚๏€ƒ ๏€ณ๏€ณ ๏€‚๏€™๏€ EN DE FR NL PL RO ๏€Ž๏€Ž ๏€ค ๏€ฒ๏€ธ๏€—๏€๏€‘๏€๏€๏€“๏€‘๏€ข๏€Œ๏€’๏€—๏€๏€ก๏€•๏€๏€ฆ๏€๏€‘ WS ๏€ ๏€ฅ ๏€ค ๏€ ๏€๏€‘๏€ป๏€จ๏€–๏€๏€š๏€ป๏€๏€ฆ๏€š๏€š๏€‘ Isolator switch ๏€ผ๏€‚ ๏€ค ๏€ฑ๏€๏€ป๏€๏€‘๏€Œ๏€๏€ฌ Reparatur schalter ๏€๏€‚ ๏€ค ๏€ญ๏€๏€ฌ๏€๏€ฆ๏€ป๏€ฆ๏€๏€ง๏€“๏€พ๏€•๏€ง๏€—๏€Œ๏€•๏€๏€๏€๏€ฆ๏€ฟ๏€“ L’interrupteur de proximité Werkschakelaar Wyล‚acznik serwisowy Switch pentru izolare ๏€ญ ๏€Œ๏€“๏€๏€“๏€๏€“๏€•๏€“๏€ก๏€“๏€š๏€“๏€—๏€“๏€Œ๏€“๏€ก๏€“๏€๏€“๏€ช๏€“๏€š๏€“๏€ฆ๏€“๏€ฆ๏€“๏€๏€“๏€๏€“๏€๏€“๏€๏€“๏€Œ๏€“๏€ซ๏€“๏€ข๏€“๏€๏€“๏€ฌ TT Black bulb sensor Schwarze kugel fühler Capteur globe noir Zwarte bol voeler ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€”๏€•๏€๏€๏€๏€–๏€— Czujnik Czarna kula Senzor glob F1 Fuse Sicherung Fusible Zekering Bezpiecznik Fitil Y1 2 / 3-way valve (optional) 2 / 3-wege ventil (optional) 2 / 3-voies vanne (optional) 2 / 3-wegklep (optioneel) ๏€Ž๏€š๏€๏€๏€๏€‘๏€“๏€›๏€œ๏€๏€“๏€ฒ๏€” Zawór 2 / 3-drogowy (Opcja) Supapฤƒ 2 / 3 cฤƒi (Optional) ๏€ฅ๏€–๏€๏€š๏€ฆ๏€—๏€ง๏€ฆ๏€š๏€๏€ค ๏€๏€ข๏€’๏€’๏€๏€‘ ๏€˜๏€๏€—๏€™ ๏€Ÿ๏€™๏€ ๏€™ ๏€œ๏€š๏€—๏€ข๏€’ ๏€˜๏€๏€–๏€™ ๏€Ž๏€ก๏€œ ๏€ฃ๏€•๏€‘๏€’ ๏€‚๏€ค๏€†๏€ค๏€ƒ๏€๏€‚๏€‰ ๏€˜๏€‘๏€ข๏€ง๏€ง๏€ ๏€Ž๏€๏€๏€‘๏€’๏€•๏€จ๏€—๏€š๏€—๏€จ ๏€๏€‘๏€—๏€™๏€๏€‘ 89 ๏€Ž๏€ช๏€ค๏€๏€‡๏€ƒ๏€Š๏€‚๏€๏€‰ ๏€Ž๏€ฉ๏€ง๏€ ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’ ๏€ž๏€๏€‘๏€จ๏€Œ๏€•๏€ ๏€‚๏€™๏€ ๏€ [7] ๏€‚ ๏€ƒ ๏€„ ๏€… ๏€† ๏€‡ ๏€ˆ ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€–๏€•๏€๏€๏€๏€–๏€—๏€“๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€‚๏€๏€‰ ๏€‰ ๏€Š ๏€‚๏€ ๏€‚๏€‚ ๏€‚๏€ƒ ๏€‚๏€„ ๏€‚๏€… ๏€‚๏€† ๏€‚๏€‡ ๏€‚๏€ˆ ๏€‚๏€‰ ๏€‚๏€„ ๏€‚๏€… ๏€‚๏€† ๏€‚๏€‡ ๏€‚๏€ˆ ๏€‚๏€‰ ๏€ฒ๏€”๏๏€ผ๏€๏€ฃ๏€“๏€ ๏€…๏€ƒ๏€ณ๏€ ๏€‰๏€ƒ๏€ณ๏€ ๏€‚๏€…๏€ƒ ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€”๏€•๏€๏€๏€๏€–๏€—๏€“๏€“๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€‚๏€๏€‰ ๏€ ๏€ญ ๏€ฏ ๏€ค ๏€‚๏€‚ ๏€‚๏€ƒ ๏€ฃ ๏€ฐ ๏€ƒ๏€‚ ๏€ƒ๏€„ ๏€ƒ๏€ƒ ๏€ƒ๏€… ๏€ƒ๏€† ๏€ƒ๏€‡ ๏€‚๏€„ ๏€‚๏€… ๏€›๏€•๏€น๏€ฎ๏€ข๏€จ ๏€‚ ๏€ญ๏€ธ ๏€ƒ ๏€‚ ๏€ƒ ๏€ผ๏€‚ ๏€‡๏€ ๏€ฃ๏€Ž๏€”๏€“๏€…๏€ถ๏€ˆ๏€ท ๏€Ž๏€”๏€‹๏€ณ๏€บ๏€‹ ๏€ฎ ๏€Ž๏€Ž ๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€๏€‰๏€‡ ๏€‹๏€ฒ ๏€ฃ ๏€ฐ๏€‚ ๏€‚๏€ต๏€ƒ๏€„๏€๏€ž๏€“๏€ฏ๏€“๏€‹๏€ฒ๏€ณ๏€†๏€๏€ช๏€ซ ๏€ ๏€ฅ ๏€‚ ๏€„ ๏€ƒ ๏€… ๏€‚ ๏€ƒ ๏€„ ๏€… ๏€† ๏€ฒ๏€”๏๏€ผ๏€๏€ฃ๏€“๏€ ๏€…๏€ƒ๏€ณ๏€ ๏€‰๏€ƒ๏€ณ๏€ ๏€‚๏€…๏€ƒ ๏€ [8] ๏€‚ ๏€ƒ ๏€„ ๏€… ๏€† ๏€‡ ๏€ˆ ๏€ค ๏€ฒ๏€ธ๏€—๏€๏€‘๏€๏€๏€“๏€‘๏€ข๏€Œ๏€’๏€—๏€๏€ก๏€•๏€๏€ฆ๏€๏€‘ ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€–๏€•๏€๏€๏€๏€–๏€—๏€“๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€‚๏€๏€‰ ๏€ค ๏€ ๏€๏€‘๏€ป๏€จ๏€–๏€๏€š๏€ป๏€๏€ฆ๏€š๏€š๏€‘ ๏€ผ๏€‚ ๏€ค ๏€ฑ๏€๏€ป๏€๏€‘๏€Œ๏€๏€ฌ ๏€ ๏€Ž๏€”๏€‹๏€ณ๏€บ๏€‹ ๏€Š ๏€‚๏€ ๏€‚๏€‚ ๏€‚๏€ƒ ๏€Ž๏€ช๏€ค๏€๏€‡๏€ƒ๏€Š๏€‚๏€๏€‰ ๏€ณ๏€ณ ๏€ƒ๏€ ๏€ณ๏€ณ ๏€‚๏€™๏€ ๏€ฒ๏€”๏๏€ผ๏€๏€ฃ๏€“๏€ ๏€…๏€ƒ๏€ณ๏€ ๏€‰๏€ƒ๏€ณ๏€ ๏€‚๏€…๏€ƒ๏€“๏€พ๏€ฒ๏€”๏€ค๏€ผ๏€๏€ฃ๏€ฟ ๏€Ž๏€Ž ๏€ ๏€ฅ ๏€‰ ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€”๏€•๏€๏€๏€๏€–๏€—๏€“๏€“๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€‚๏€๏€‰ ๏€ฎ ๏€ญ ๏€ฏ ๏€ค ๏€‚๏€‚ ๏€‚๏€ƒ ๏€ฃ ๏€ฐ ๏€ƒ๏€‚ ๏€ƒ๏€„ ๏€ƒ๏€ƒ ๏€ƒ๏€… ๏€ƒ๏€† ๏€ƒ๏€‡ ๏€‚๏€„ ๏€‚๏€… ๏€›๏€•๏€น๏€ฎ๏€ข๏€จ ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€”๏€•๏€๏€๏€๏€–๏€— ๏€ญ ๏€Œ๏€“๏€๏€“๏€๏€“๏€•๏€“๏€ก๏€“๏€š๏€“๏€—๏€“๏€Œ๏€“๏€ก๏€“๏€๏€“๏€ช๏€“๏€š๏€“๏€ฆ๏€“๏€ฆ๏€“๏€๏€“๏€๏€“๏€๏€“๏€๏€“๏€Œ๏€“๏€ซ๏€“๏€ข๏€“๏€๏€“๏€ฌ ๏€ƒ ๏€‚ ๏€ƒ ๏€Ž๏€Ž ๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€๏€‰๏€‡ ๏€ƒ ๏€„ ๏€… ๏€œ๏€š๏€—๏€ข๏€’ ๏€˜๏€๏€–๏€™ ๏€Ž๏€ก๏€œ ๏€ฃ๏€•๏€‘๏€’ ๏€‚๏€ค๏€†๏€ค๏€ƒ๏€๏€‚๏€‰ ๏€˜๏€‘๏€ข๏€ง๏€ง๏€ ๏€Ž๏€ช๏€ค๏€๏€‡๏€ƒ๏€Š๏€‚๏€๏€‰ ๏€Ž๏€๏€๏€‘๏€’๏€•๏€จ๏€—๏€š๏€—๏€จ ๏€๏€‘๏€—๏€™๏€๏€‘ ๏€Ž๏€ฉ๏€ง๏€ ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’ ๏€ž๏€๏€‘๏€จ๏€Œ๏€•๏€ ๏€‚๏€™๏€ ๏€‹๏€ฒ ๏€ฃ ๏€ฐ๏€‚ ๏€‚๏€ต๏€ƒ๏€„๏€๏€ž๏€“๏€ฏ๏€“๏€‹๏€ฒ๏€ณ๏€†๏€๏€ช๏€ซ ๏€ ๏€ฅ ๏€‚ ๏€Ÿ๏€™๏€ ๏€™ ๏€ผ๏€‚ ๏€‡๏€ ๏€ฃ๏€Ž๏€”๏€“๏€…๏€ถ๏€ˆ๏€ท ๏€‚ ๏€ญ๏€ธ ๏€ฅ๏€–๏€๏€š๏€ฆ๏€—๏€ง๏€ฆ๏€š๏€๏€ค ๏€๏€ข๏€’๏€’๏€๏€‘ ๏€ฒ๏€”๏๏€ผ๏€๏€ฃ๏€“ ๏€˜๏€๏€—๏€™ ๏€‚ ๏€„ ๏€ƒ ๏€… ๏€ฐ๏€‚ ๏€† ๏€ฒ๏€‚ ๏€ฃ ๏€‹๏€ฒ ๏€›๏€‚ ๏€ฒ๏€”๏๏€ผ๏€๏€ฃ๏€“๏€ ๏€…๏€ƒ๏€ณ๏€ ๏€‰๏€ƒ๏€ณ๏€ ๏€‚๏€…๏€ƒ๏€“๏€พ๏€ฒ๏€”๏€ค๏€ผ๏€๏€ฃ๏€ฟ ๏€Ž๏€ช๏€ค๏€๏€‡๏€ƒ๏€Š๏€‚๏€๏€‰ ๏€ณ๏€ณ ๏€ƒ๏€‚ ๏€ณ๏€ณ ๏€‚๏€™๏€ EN DE FR NL PL RO 90 WS ๏€Ž๏€Ž ๏€ค ๏€ฒ๏€ธ๏€—๏€๏€‘๏€๏€๏€“๏€‘๏€ข๏€Œ๏€’๏€—๏€๏€ก๏€•๏€๏€ฆ๏€๏€‘ ๏€ ๏€ฅ ๏€ค ๏€ ๏€๏€‘๏€ป๏€จ๏€–๏€๏€š๏€ป๏€๏€ฆ๏€š๏€š๏€‘ Isolator switch ๏€ผ๏€‚ ๏€ค ๏€ฑ๏€๏€ป๏€๏€‘๏€Œ๏€๏€ฌ Reparatur schalter ๏€๏€‚ ๏€ค ๏€„๏€ค๏€ฝ๏€๏€ฌ๏€ป๏€ฆ๏€๏€ง๏€“๏€พ๏€•๏€ง๏€—๏€Œ๏€•๏€๏€๏€๏€ฆ๏€ฟ๏€“ L’interrupteur de proximité Werkschakelaar Wyล‚acznik serwisowy Switch pentru izolare ๏€ญ ๏€Œ๏€“๏€๏€“๏€๏€“๏€•๏€“๏€ก๏€“๏€š๏€“๏€—๏€“๏€Œ๏€“๏€ก๏€“๏€๏€“๏€ช๏€“๏€š๏€“๏€ฆ๏€“๏€ฆ๏€“๏€๏€“๏€๏€“๏€๏€“๏€๏€“๏€Œ๏€“๏€ซ๏€“๏€ข๏€“๏€๏€“๏€ฌ TT Black bulb sensor Schwarze kugel fühler Capteur globe noir Zwarte bol voeler ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€”๏€•๏€๏€๏€๏€–๏€— Czujnik Czarna kula Senzor glob F1 Fuse Sicherung Fusible Zekering Bezpiecznik Fitil Y1 3-way valve (optional) 3-wege ventil (optional) 3-voies vanne (optional) 3-wegklep (optioneel) ๏€ฒ๏€”๏๏€ผ๏€๏€ฃ๏€“๏€พ๏€๏€–๏€ค๏‚๏€š๏€๏€ฟ Zawór 3-drogowy (Opcja) Supapฤƒ cutrei cฤƒi (Optional) ๏€ฅ๏€–๏€๏€š๏€ฆ๏€—๏€ง๏€ฆ๏€š๏€๏€ค ๏€๏€ข๏€’๏€’๏€๏€‘ ๏€˜๏€๏€—๏€™ ๏€Ÿ๏€™๏€ ๏€™ ๏€œ๏€š๏€—๏€ข๏€’ ๏€˜๏€๏€–๏€™ ๏€Ž๏€ก๏€œ ๏€ฃ๏€•๏€‘๏€’ ๏€‚๏€ค๏€†๏€ค๏€ƒ๏€๏€‚๏€‰ ๏€˜๏€‘๏€ข๏€ง๏€ง๏€ ๏€๏€‘๏€—๏€™๏€๏€‘ ๏€Ž๏€๏€๏€‘๏€’๏€•๏€จ๏€—๏€š๏€—๏€จ ๏€Ž๏€ช๏€ค๏€๏€‡๏€ƒ๏€Š๏€‚๏€๏€‰ ๏€Ž๏€ฉ๏€ง๏€ ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’ ๏€ž๏€๏€‘๏€จ๏€Œ๏€•๏€ ๏€‚๏€™๏€ ๏€ [9] ๏€‚ ๏€ƒ ๏€„ ๏€… ๏€† ๏€‡ ๏€ˆ ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€–๏€•๏€๏€๏€๏€–๏€—๏€“๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€‚๏€๏€‰ ๏€‰ ๏€Š ๏€‚๏€ ๏€‚๏€‚ ๏€‚๏€ƒ ๏€‚๏€„ ๏€‚๏€… ๏€‚๏€† ๏€‚๏€‡ ๏€‚๏€ˆ ๏€‚๏€‰ ๏€›๏€œ๏€ž๏€“๏€พ๏€ฒ๏€”๏€ค๏€ผ๏€๏€ฃ๏€“๏€ƒ๏€„๏€๏€ž๏€ฟ ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€”๏€•๏€๏€๏€๏€–๏€—๏€“๏€“๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€‚๏€๏€‰ ๏€ ๏€Ž๏€”๏€‹๏€ณ๏€บ๏€‹ ๏€ฎ ๏€ญ ๏€ฏ ๏€ค ๏€‚๏€‚ ๏€‚๏€ƒ ๏€ฃ ๏€ฐ ๏€ƒ๏€‚ ๏€ƒ๏€„ ๏€ƒ๏€ƒ ๏€ƒ๏€… ๏€ƒ๏€† ๏€ƒ๏€‡ ๏€‚๏€„ ๏€‚๏€… ๏€›๏€•๏€น๏€ฎ๏€ข๏€จ ๏€Ž๏€Ž ๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€๏€‰๏€‡ ๏€‹๏€ฒ ๏€ฃ ๏€ฐ๏€‚ ๏€‚๏€ต๏€ƒ๏€„๏€๏€ž๏€“๏€ฏ๏€“๏€‹๏€ฒ๏€ณ๏€†๏€๏€ช๏€ซ ๏€ ๏€ฅ ๏€„ ๏€ƒ ๏€… ๏€ฝ๏€๏€“๏€ƒ ๏€ฝ๏€๏€“๏€‚ ๏€ฉ๏€๏€ณ๏€ฌ๏€‘ ๏€ฝ๏€ ๏…๏€‘ ๏€‘๏€น ๏…๏€ฆ ๏€ฒ๏€‚ ๏€ฉ๏€ ๏€ฒ๏€ƒ ๏€‚ ๏…๏€ฆ ๏€ƒ ๏€‚ ๏€ƒ ๏€ฎ๏€ท ๏€‚ ๏€ญ๏€ธ ๏€ฃ๏€Ž๏€”๏€“๏€…๏€ถ๏€ˆ๏€ท ๏€ผ๏€‚ ๏€‡๏€ ๏€ท ๏€›๏€œ๏€ž๏€“๏€ฒ๏€” EN DE FR NL PL RO WS๏€Ž๏€Ž ๏€ค ๏€ฒ๏€ธ๏€—๏€๏€‘๏€๏€๏€“๏€‘๏€ข๏€Œ๏€’๏€—๏€๏€ก๏€•๏€๏€ฆ๏€๏€‘ ๏€ ๏€ฅ ๏€ค ๏€ ๏€๏€‘๏€ป๏€จ๏€–๏€๏€š๏€ป๏€๏€ฆ๏€š๏€š๏€‘ Isolator ๏€ผ๏€‚ ๏€ค switch ๏€ฑ๏€๏€ป๏€๏€‘๏€Œ๏€๏€ฌ ๏€ฒ๏€‚๏€ถ๏€ฒ๏€ƒ ๏€ค ๏€๏€š๏€๏€จ๏€ฆ๏€ข๏€Œ๏€—๏…๏€•๏€ธ๏€“๏€›๏€œ๏€ž Reparatur schalter L’interrupteur de proximité Werkschakelaar Wyล‚acznik serwisowy Switch pentru izolare ๏€ญ ๏€Œ๏€“๏€๏€“๏€๏€“๏€•๏€“๏€ก๏€“๏€š๏€“๏€—๏€“๏€Œ๏€“๏€ก๏€“๏€๏€“๏€ช๏€“๏€š๏€“๏€ฆ๏€“๏€ฆ๏€“๏€๏€“๏€๏€“๏€๏€“๏€๏€“๏€Œ๏€“๏€ซ๏€“๏€ข๏€“๏€๏€“๏€ฌ TT Black bulb sensor Schwarze kugel fühler Capteur globe noir Zwarte bol voeler ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€”๏€•๏€๏€๏€๏€–๏€— Czujnik Czarna kula Senzor glob ๏€Ž๏€ช๏€ค๏€๏€‡๏€ƒ๏€Š๏€‚๏€๏€‰ ๏€ณ๏€ณ ๏€†๏€ ๏€ณ๏€ณ ๏€‚๏€™๏€ F1 Fuse Sicherung Fusible Zekering Bezpiecznik Fitil E1,E2 Connection box MDV Verbindungsbox MDV Boîte de connexion MDV Aansluitbox MDV ๏€›๏€œ๏€ž๏€“๏€พ๏€๏€–๏€ค๏‚๏€š๏€๏€ฟ Skrzynka przyล‚ฤ…czeniowa MDV Caseta de conectare MDV ๏€ฅ๏€–๏€๏€š๏€ฆ๏€—๏€ง๏€ฆ๏€š๏€๏€ค ๏€๏€ข๏€’๏€’๏€๏€‘ ๏€˜๏€๏€—๏€™ ๏€Ÿ๏€™๏€ ๏€™ ๏€œ๏€š๏€—๏€ข๏€’ ๏€˜๏€๏€–๏€™ ๏€Ž๏€ก๏€œ ๏€ฃ๏€•๏€‘๏€’ ๏€‚๏€ค๏€†๏€ค๏€ƒ๏€๏€‚๏€‰ ๏€˜๏€‘๏€ข๏€ง๏€ง๏€ ๏€Ž๏€๏€๏€‘๏€’๏€•๏€จ๏€—๏€š๏€—๏€จ ๏€๏€‘๏€—๏€™๏€๏€‘ ) 91 ๏€Ž๏€ช๏€ค๏€๏€‡๏€ƒ๏€Š๏€‚๏€๏€‰ ๏€Ž๏€ฉ๏€ง๏€ ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’ ๏€ž๏€๏€‘๏€จ๏€Œ๏€•๏€ ๏€‚๏€™๏€ ๏€ ๏€‚ [10] ๏€ƒ ๏€„ ๏€… ๏€† ๏€‡ ๏€ˆ ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€–๏€•๏€๏€๏€๏€–๏€—๏€“๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€‚๏€๏€‰ ๏€‰ ๏€Š ๏€‚๏€ ๏€‚๏€‚ ๏€‚๏€ƒ ๏€‚๏€„ ๏€‚๏€… ๏€‚๏€† ๏€‚๏€‡ ๏€‚๏€ˆ ๏€‚๏€‰ ๏€›๏€œ๏€ž๏€“๏€พ๏€ฒ๏€”๏€ค๏€ผ๏€๏€ฃ๏€“๏€…๏€๏€๏€ž๏€ฟ ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€”๏€•๏€๏€๏€๏€–๏€—๏€“๏€“๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€‚๏€๏€‰ ๏€ ๏€Ž๏€”๏€‹๏€ณ๏€บ๏€‹ ๏€ฎ ๏€ญ ๏€ฏ ๏€ค ๏€‚๏€‚ ๏€‚๏€ƒ ๏€ฃ ๏€ฐ ๏€ƒ๏€‚ ๏€ƒ๏€ƒ ๏€ƒ๏€„ ๏€ƒ๏€… ๏€ƒ๏€† ๏€ƒ๏€‡ ๏€‚๏€„ ๏€‚๏€… ๏€›๏€•๏€น๏€ฎ๏€ข๏€จ ๏€„๏€ต๏€“๏€…๏€๏€๏€ž๏€“๏€ฏ๏€‹๏€ฒ๏€“๏€ณ๏€“๏€†๏€๏€ช๏€ซ ๏€ฐ๏€ƒ ๏€ฐ๏€„ ๏€‹๏€ฒ ๏€‚ ๏€ผ๏€ƒ ๏€ญ๏€ธ ๏€‚ ๏€ƒ ๏€ƒ ๏€Ž๏€Ž ๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€๏€‰๏€‡ ๏€ ๏€ฅ ๏€‚ ๏€„ ๏€„ ๏€ƒ ๏€… ๏€… ๏€ฐ๏€‚ ๏€ฐ๏€ƒ ๏€ฐ๏€„ ๏€ท๏€ฐ๏€“๏€‚ ๏€ผ๏€‚ ๏€‡๏€ ๏€ฃ๏€Ž๏€”๏€“๏€…๏€ถ๏€ˆ๏€ท ๏€ฐ๏€‚ ๏€‹๏€ฒ ๏€ฃ ๏€ฐ๏€‚ ๏€‚๏€ต๏€ƒ๏€„๏€๏€ž๏€“๏€ฏ๏€“๏€‹๏€ฒ๏€ณ๏€†๏€๏€ช๏€ซ ๏€๏€Œ๏€๏€‚ ๏€˜๏€ฃ๏€œ ๏€ด ๏€ท๏€ฐ๏€“๏€ƒ ๏€›๏€œ๏€ž๏€“๏€ฒ๏€” EN DE FR NL PL RO 92 ๏€Ž๏€Ž ๏€ค ๏€ฒ๏€ธ๏€—๏€๏€‘๏€๏€๏€“๏€‘๏€ข๏€Œ๏€’๏€—๏€๏€ก๏€•๏€๏€ฆ๏€๏€‘ WS ๏€ ๏€ฅ ๏€ค ๏€ ๏€๏€‘๏€ป๏€จ๏€–๏€๏€š๏€ป๏€๏€ฆ๏€š๏€š๏€‘ Isolator switch ๏€ผ๏€‚๏€ถ๏€ผ๏€ƒ ๏€ค ๏€ฑ๏€๏€ป๏€๏€‘๏€Œ๏€๏€ฌ Reparatur schalter ๏€๏€‚ ๏€ค ๏€„๏€ค๏€ฝ๏€๏€ฌ๏€ป๏€ฆ๏€๏€ง๏€“๏€พ๏€•๏€ง๏€—๏€Œ๏€•๏€๏€๏€๏€ฆ๏€ฟ๏€“ L’interrupteur de proximité Werkschakelaar Wyล‚acznik serwisowy Switch pentru izolare ๏€ญ ๏€Œ๏€“๏€๏€“๏€๏€“๏€•๏€“๏€ก๏€“๏€š๏€“๏€—๏€“๏€Œ๏€“๏€ก๏€“๏€๏€“๏€ช๏€“๏€š๏€“๏€ฆ๏€“๏€ฆ๏€“๏€๏€“๏€๏€“๏€๏€“๏€๏€“๏€Œ๏€“๏€ซ๏€“๏€ข๏€“๏€๏€“๏€ฌ ๏€Ž๏€ช๏€ค๏€๏€‡๏€ƒ๏€Š๏€‚๏€๏€‰ ๏€ณ๏€ณ ๏€†๏€‚ ๏€ณ๏€ณ ๏€‚๏€™๏€ TT Black bulb sensor Schwarze kugel fühler Capteur globe noir Zwarte bol๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€”๏€•๏€๏€๏€๏€–๏€— voeler Czujnik Czarna kula Senzor glob F1 Fuse Sicherung Fusible Zekering Bezpiecznik Fitil Y1 3-way valve (optional) 3-wege ventil (optional) 3-voies vanne (optional) 3-wegklep (optioneel) ๏€›๏€œ๏€ž๏€“๏€พ๏€๏€–๏€ค๏‚๏€š๏€๏€ฟ Zawór 3-drogowy (Opcja) Supapฤƒ cutrei cฤƒi (Optional) ๏€ฅ๏€–๏€๏€š๏€ฆ๏€—๏€ง๏€ฆ๏€š๏€๏€ค ๏€๏€ข๏€’๏€’๏€๏€‘ ๏€˜๏€๏€—๏€™ ๏€Ÿ๏€™๏€ ๏€™ ๏€œ๏€š๏€—๏€ข๏€’ ๏€˜๏€๏€–๏€™ ๏€Ž๏€ก๏€œ ๏€ฃ๏€•๏€‘๏€’ ๏€‚๏€ค๏€†๏€ค๏€ƒ๏€๏€‚๏€‰ ๏€˜๏€‘๏€ข๏€ง๏€ง๏€ ๏€๏€‘๏€—๏€™๏€๏€‘ ๏€Ž๏€๏€๏€‘๏€’๏€•๏€จ๏€—๏€š๏€—๏€จ ๏€Ž๏€ช๏€ค๏€๏€‡๏€ƒ๏€Š๏€‚๏€๏€‰ ๏€Ž๏€ฉ๏€ง๏€ ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’ ๏€ž๏€๏€‘๏€จ๏€Œ๏€•๏€ ๏€‚๏€™๏€ ) al) ๏€ ๏€‚ ๏€ƒ ๏€„ ๏€… ๏€† ๏€‡ ๏€ˆ ๏€‰ ๏€Š ๏€‚๏€ ๏€‚๏€‚ ๏€‚๏€ƒ ๏€‚๏€„ ๏€‚๏€… ๏€‚๏€† ๏€‚๏€‡ ๏€‚๏€ˆ ๏€‚๏€‰ [11] ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€”๏€•๏€๏€๏€๏€–๏€—๏€“๏€“๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€‚๏€๏€‰ ๏€ฆ ๏€Ž๏€”๏€‹๏€ฑ๏€ด๏€‹ ๏€ฎ ๏€ญ ๏€ฏ ๏€ข ๏€‚๏€‚ ๏€‚๏€ƒ ๏€ก ๏€ฐ ๏€ƒ๏€‚ ๏€ƒ๏€ƒ ๏€ƒ๏€„ ๏€ƒ๏€… ๏€ƒ๏€† ๏€ƒ๏€‡ ๏€‚๏€„ ๏€‚๏€… ๏€‚ ๏€ƒ ๏€ƒ ๏€Ž๏€Ž ๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€๏€‰๏€‡ ๏€‚ ๏€ƒ ๏€ƒ ๏€Ž๏€Ž ๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€๏€‰๏€‡ ๏€‚ ๏€ญ๏€š ๏€‚ ๏€ƒ ๏€ƒ ๏€ก๏€Ž๏€”๏€“๏€…๏€ต๏€ˆ๏€ถ ๏€ƒ ๏€‚ ๏€ญ๏€š ๏€ก๏€Ž๏€”๏€“๏€…๏€ต๏€ˆ๏€ถ ๏€‚ ๏€ƒ ๏€Ž๏€Ž ๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€๏€‰๏€‡ ๏€‚ ๏€ญ๏€š ๏€ก๏€Ž๏€”๏€“๏€…๏€ต๏€ˆ๏€ถ ๏€‚ ๏€ญ๏€š ๏€ก๏€Ž๏€”๏€“๏€…๏€ต๏€ˆ๏€ถ ๏€ฒ๏€•๏€ณ๏€ฎ๏€ ๏€ง ๏€Ž๏€Ž ๏€๏€‡๏€™๏€ƒ๏€Š๏€™๏€๏€‰๏€‡ ๏€Ž๏€ช๏€ข๏€๏€‡๏€ƒ๏€Š๏€‚๏€๏€‰ ๏€ฑ๏€ฑ ๏€Š๏€ ๏€ฑ๏€ฑ ๏€‚๏€™๏€ ๏€Ž๏€Ž EN DE FR NL PL ๏€ข ๏€ท๏€š๏€—๏€๏€‘๏€๏€๏€“๏€‘๏€ ๏€Œ๏€’๏€—๏€๏€๏€•๏€๏€ค๏€๏€‘ TT Black bulb sensor Schwarze kugel fühler Capteur globe noir Zwarte bol voeler Czujnik Czarna kula Senzor glob ๏€ญ ๏€Œ๏€“๏€๏€“๏€๏€“๏€•๏€“๏€๏€“๏€Ÿ๏€“๏€—๏€“๏€Œ๏€“๏€๏€“๏€๏€“๏€ช๏€“๏€Ÿ๏€“๏€ค๏€“๏€ค๏€“๏€๏€“๏€๏€“๏€๏€“๏€๏€“๏€Œ๏€“๏€ซ๏€“๏€ ๏€“๏€๏€“๏€ฌ RO ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’๏€“๏€”๏€•๏€๏€๏€๏€–๏€— ๏€ฃ๏€–๏€๏€Ÿ๏€ค๏€—๏€ฅ๏€ค๏€Ÿ๏€๏€ข ๏€๏€ ๏€’๏€’๏€๏€‘ ๏€…๏€š๏€“๏€Ž๏€Ž ๏€˜๏€๏€—๏€™ ๏€›๏€™๏€œ๏€™ ๏€ž๏€Ÿ๏€—๏€ ๏€’ ๏€˜๏€๏€–๏€™ ๏€Ž๏€๏€ž ๏€ก๏€•๏€‘๏€’ ๏€‚๏€ข๏€†๏€ข๏€ƒ๏€๏€‚๏€‰ ๏€˜๏€‘๏€ ๏€ฅ๏€ฅ๏€ ๏€Ž๏€ช๏€ข๏€๏€‡๏€ƒ๏€Š๏€‚๏€๏€‰ ๏€Ž๏€๏€๏€‘๏€’๏€•๏€ง๏€—๏€Ÿ๏€—๏€ง ๏€ฆ๏€‘๏€—๏€™๏€๏€‘ 93 ๏€Ž๏€จ๏€ฅ๏€ ๏€‹๏€Œ๏€๏€Ž๏€๏€๏€‘๏€’ ๏€ฉ๏€๏€‘๏€ง๏€Œ๏€•๏€ ๏€‚๏€™๏€ [12] Modbus RTU Baudrate 19200 Data bits 8 Parity Even Stop bits 1 Slave ID 1-247 Minimum read-request interval 100 msec or longer Response timeout 500 msec Modbus TCP Port 502 Slave ID 255 Minimum read-request interval 50 msec or longer Response timeout 94 500 msec (default: 1) Serial number bytes 0..1 Serial number bytes 2..3 Serial number bytes 4..5 Language 4 5 6 7 0-1 0- 1 0..39 0..39 -35..35 0..3 32 R/W Heat Request 33 R/W High/low mode active 34 R/W Temperature Day 35 R/W Temperature Night 36 R/W Temperature calibration 37 R/W High/low Switch 1 .. 3K, 0 = Manual Mode 0 - No heat request 1 - Heat request 0 - Low mode active 1 - High mode active 0..39°C 0..39°C -3.5 .. +3.5°C 0/60/120/180 - 60/120/180 minutes - 0 to deactivate the overtime Automatically counts down to zero 18 R/W Overtime Timer 0 - normal 1 - fault 0 - no reset active 1 - perform reset ( write 1 to reset, auto-cleared when reset sequence has completed +- 12 seconds) 0 - NL 1 - EN 2 - DE 3 - FR 4 - PL 5 - RO 6 - LT MSB: Major LSB: Minor MSB: Branch LSB: Revision Range/Settings 0-1 0-1 0..65535 0..65535 0..65535 0..6 0..65535 0..65535 Raw Value 17 R/W Fault reset Gas Burner fault Firmware version Branch/Revision 3R R R R R/W HOLING REGISTERS Vendor ID Product ID Firmware version Minor/Major 0R 1R 2R R/W Description 16 R Register Address Notes [13] 95 96 1..12 1900.. 0-1 0..59 0..59 0..23 0..31 1..12 0..9999 52 R/W Vacation planning end month 53 R/W Vacation planning end year 54 R/W Vacation planning active Current Date/Time 55 R/W Current time Seconds 56 R/W Current time Minutes 57 R/W Current time Hours 58 R/W Current date Day 59 R/W Current date Month 60 R/W Current date Year 0..2359 0..2359 0..2359 0..2359 0..2359 1..31 51 R/W Vacation planning end day Sunday Program 1 Start Program 1 End Program 2 Start Program 2 End Program 3 Start 1900.. 50 R/W Vacation planning start year R/W R/W R/W R/W R/W 1..12 49 R/W Vacation planning start month 64 65 66 67 68 1..31 Switching differential L1 Switching differential L3 0-1 5/10/15/20 48 R/W Vacation planning start day 44 R 45 R 38 R/W Modulating Control 39 R/W Minimal Activation Time Hours in multiples of 100 plus minutes (1230 means 12:30) Hours in multiples of 100 plus minutes (1230 means 12:30) Hours in multiples of 100 plus minutes (1230 means 12:30) Hours in multiples of 100 plus minutes (1230 means 12:30) Hours in multiples of 100 plus minutes (1230 means 12:30) 1..12 month of year Current year between 0..9999 0..31 day of month 0..23 Hours 0..59 minutes 0..59 seconds 1..12 1900.. 0 = inactive, 1 = active 1..31 1900.. 1..12 1..31 10 1K 5 0.5K 0 = Inactive, 1 = Active 5, 10, 15 or 20 Min The date/time is automatically validated when a write request is completed. When the date/time is invalid the date/time will not be updated To write the vacation planning it's adviced to use use function 0x10 ( Write Multiple Registers). With a Write Single Register request, the old data and new data can form a invalid date. To write the vacation planning it's adviced to use use function 0x10 ( Write Multiple Registers). With a Write Single Register request, the old data and new data can form a invalid date. The dates are automatically validated when a write request is completed When the date is invalid, the date will not be updated. 97 0..2359 0..2359 0..2359 0..2359 0..2359 0..2359 0..2359 Thursday Program 1 Start Program 1 End Program 2 Start Program 2 End Program 3 Start Program 3 End Friday 144 R/W Program 1 Start R/W R/W R/W R/W R/W R/W 128 129 130 131 132 133 0..2359 0..2359 0..2359 0..2359 0..2359 0..2359 Wednesday Program 1 Start Program 1 End Program 2 Start Program 2 End Program 3 Start Program 3 End R/W R/W R/W R/W R/W R/W 112 113 114 115 116 117 0..2359 0..2359 0..2359 0..2359 0..2359 0..2359 Tuesday Program 1 Start Program 1 End Program 2 Start Program 2 End Program 3 Start Program 3 End R/W R/W R/W R/W R/W R/W 96 97 98 99 100 101 0..2359 0..2359 0..2359 0..2359 0..2359 0..2359 Monday Program 1 Start Program 1 End Program 2 Start Program 2 End Program 3 Start Program 3 End R/W R/W R/W R/W R/W R/W 80 81 82 83 84 85 0..2359 69 R/W Program 3 End Hours in multiples of 100 plus minutes (1230 means 12:30) Hours in multiples of 100 plus minutes (1230 means 12:30) Hours in multiples of 100 plus minutes (1230 means 12:30) Hours in multiples of 100 plus minutes (1230 means 12:30) Hours in multiples of 100 plus minutes (1230 means 12:30) Hours in multiples of 100 plus minutes (1230 means 12:30) Hours in multiples of 100 plus minutes (1230 means 12:30) Hours in multiples of 100 plus minutes (1230 means 12:30) Hours in multiples of 100 plus minutes (1230 means 12:30) Hours in multiples of 100 plus minutes (1230 means 12:30) Hours in multiples of 100 plus minutes (1230 means 12:30) Hours in multiples of 100 plus minutes (1230 means 12:30) Hours in multiples of 100 plus minutes (1230 means 12:30) Hours in multiples of 100 plus minutes (1230 means 12:30) Hours in multiples of 100 plus minutes (1230 means 12:30) Hours in multiples of 100 plus minutes (1230 means 12:30) Hours in multiples of 100 plus minutes (1230 means 12:30) Hours in multiples of 100 plus minutes (1230 means 12:30) Hours in multiples of 100 plus minutes (1230 means 12:30) Hours in multiples of 100 plus minutes (1230 means 12:30) Hours in multiples of 100 plus minutes (1230 means 12:30) Hours in multiples of 100 plus minutes (1230 means 12:30) Hours in multiples of 100 plus minutes (1230 means 12:30) Hours in multiples of 100 plus minutes (1230 means 12:30) Hours in multiples of 100 plus minutes (1230 means 12:30) Hours in multiples of 100 plus minutes (1230 means 12:30) 98 R/W R/W R/W R/W R/W R/W 160 161 162 163 164 165 0 R/W R/W R/W R/W R/W 145 146 147 148 149 0..2359 0..2359 0..2359 0..2359 0..2359 0..2359 0..2359 0..2359 0..2359 0..2359 0..2359 -100..950 Program 1 End Program 2 Start Program 2 End Program 3 Start Program 3 End Saturday Program 1 Start Program 1 End Program 2 Start Program 2 End Program 3 Start Program 3 End Input Register Temperature -10.0..95.0°C Hours in multiples of 100 plus minutes (1230 means 12:30) Hours in multiples of 100 plus minutes (1230 means 12:30) Hours in multiples of 100 plus minutes (1230 means 12:30) Hours in multiples of 100 plus minutes (1230 means 12:30) Hours in multiples of 100 plus minutes (1230 means 12:30) Hours in multiples of 100 plus minutes (1230 means 12:30) Hours in multiples of 100 plus minutes (1230 means 12:30) Hours in multiples of 100 plus minutes (1230 means 12:30) Hours in multiples of 100 plus minutes (1230 means 12:30) Hours in multiples of 100 plus minutes (1230 means 12:30) Hours in multiples of 100 plus minutes (1230 means 12:30) 99 MARK BV BENEDEN VERLAAT 87-89 VEENDAM (NEDERLAND) POSTBUS 13, 9640 AA VEENDAM TELEFOON +31(0)598 656600 FAX +31 (0)598 624584 [email protected] www.mark.nl MARK DEUTSCHLAND GmbH MAX-PLANCK-STRASSE 16 46446 EMMERICH AM RHEIN (DEUTSCHLAND) TELEFON +49 (0)2822 97728-0 TELEFAX +49 (0)2822 97728-10 [email protected] www.mark.de MARK EIRE BV COOLEA, MACROOM CO. CORK P12 W660 (IRELAND) PHONE +353 (0)26 45334 FAX +353 (0)26 45383 [email protected] www.markeire.com MARK POLSKA Sp. z o.o UL. JASNOGÓRSKA 27 42-202 CZฤ˜STOCHOWA (POLSKA) PHONE +48 34 3683443 FAX +48 34 3683553 [email protected] www.markpolska.pl S.C. MARK ROMANIA S.R.L. STR. KOS KAROLY NR. 1 A 540297 TARGU MURES (ROMANIA) TEL/FAX +40 (0)265-266.332 [email protected] www.markromania.ro MARK BELGIUM b.v.b.a. ENERGIELAAN 12 2950 KAPELLEN (BELGIË/BELGIQUE) TELEFOON +32 (0)3 6669254 FAX +32 (0)3 6666578 [email protected] www.markbelgium.be CERTIFICATION N°: 17.07.011 AIRSTREAM CERTIFICATION N°: 17.07.011 AIRSTREAM CERTIFICATION N°: 17.07.011 AIRSTREAM CERTIFICATION N°: 17.07.011 AIRSTREAM
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100

Mark PinTherm Connect Technical Manual

Type
Technical Manual