1. Filter cleaning indicator light.
2. Blower operation indicator light.
3. Appliance operation indicator light.
4. Infrared receiver cell.
5. Appliance on/standby
.
Press the button
located on the side of the blower to switch on
the appliance (blower and appliance).
• Indicator light: Solid green - Turbo + appliance switched on.
• Filter 1 indicator light: Off.
• Off: Switched off.
• Solid green: Switched on.
• Flashing red: Working.
In the case of overheating caused by the presence of towels
or any other obstacle obstructing the blower’s air outlet
too much, the appliance’s operation is stopped (red/green
ashing of indicator lights 2 and 3). The blower’s operation
restarts when the temperature drops again, for the rest of
the pre-programmed time.
In case of overheating on the blower’s element, a thermal
safety with manual reset mechanically cuts off the blowing
function.
• Filter 1 indicator light: Flashing red.
• Blower indicator light: Solid green.
Clogging up of the lter can lead to this
overheating. Clean it if necessary.
Press the button “on / standby”
for more than 6 seconds
to clear this alarm.
Ensure you clean the lter each time the lter cleaning
alarm is triggered (see “Filter cleaning”).
If the cause of overheating is not identied, the
alarm will be triggered again. In this case, contact your
installer as without intervention, this may, over time,
damage the blower.
The FM radio infrared emitter can
send a blower Turbo start-up order
during a time adjustable by 10
minute intervals which can go up
to 2 hours (the factory congu-
ration dened by default sets the
Boost time at 30 minutes).
Select the mode required by successively pressing the Boost
button. (available in
,
mode (cf FM radio infrared
room thermostat notice)).
Boost
: Appliance boost only (Indicator light 3:
Flashing red).
Boost Blower boost only (Indicator light 2:
Flashing red).
Boost
Appliance + blower boost (indicator lights 2 and 3:
Flashing red).
The display of the Boost time countdown replaces that of
the time.
To change the Boost duration, press the +/- buttons: the
adjustment is done in steps of 10 minutes.
You can stop the forced operating at any time
by pressing the Boost button until the Boost segment
disappears.