Invacare CE0123 Handleiding

Type
Handleiding

Deze handleiding is ook geschikt voor

Invacare® Check O
2
Plus™
IRC450
ENOxygenAnalyzer
UserManual...................................3
FRAnalyseurd’oxygene
Manueld'utilisation.............................19
ESAnalizadordeoxígeno
Manualdelusuario..............................35
DESauerstoffsensor
Gebrauchsanweisung............................51
ITAnalizzatorediossigeno
Manualed’uso..................................65
NLZuurstofanalysator
Gebruiksaanwijzing..............................79
ThismanualMUSTbegiventotheuseroftheproduct.
BEFOREusingthisproduct,readthismanualandsaveforfuturereference.
©2012Invacare®Corporation
Allrightsreserved.Republication,duplicationormodificationinwholeorinpartisprohibitedwithout
priorwrittenpermissionfromInvacare.Trademarksareidentifiedby™and®.Alltrademarksare
ownedbyorlicensedtoInvacareCorporationoritssubsidiariesunlessotherwisenoted.
Contents
ThismanualMUSTbegiventotheuseroftheproduct.
BEFOREusingthisproduct,readthismanualandsaveforfuture
reference.
1General......................................4
1.1Symbols..................................4
1.2IntendedUse..............................4
2SystemOverview..............................5
2.1DescriptionandPrincipleofOperation...........5
2.2ComponentIdentification.....................5
2.3SymbolGuide.............................6
2.4ComponentDescription......................6
2.5IncludedwithYourUnit......................6
3Safety........................................7
3.1GeneralGuidelines..........................7
3.2Disposal.................................9
4OperatingInstructions..........................10
4.1Oxygen,FlowandPressureMeasurement.........10
4.2SwitchingPressureUnitsofMeasure.............10
4.3CalibrationVerificationProcedure..............10
4.4FactorsInfluencingAccurateReadings............10
EffectsofTemperature.......................10
EffectsofHumidity..........................10
EffectsofOtherGases.......................11
EffectsofLowFlow.........................11
5ErrorCodes..................................12
5.1ErrorCodes..............................12
6ChangingtheBatteries.........................13
6.1BatteryReplacementProcedure................13
7CleaningandMaintenance.......................14
7.1Cleaning.................................14
7.2Maintenance..............................14
8TechnicalData................................15
8.1ProductParameters.........................15
9Warranty.....................................16
9.1WarrantyNorthAmerica..................16
9.2WarrantyEurope........................17
1General
1.1Symbols
Signalwordsareusedinthismanualandapplytohazardsorunsafe
practiceswhichcouldresultinpersonalinjuryorpropertydamage.
Seetheinformationbelowfordefinitionsofthesignalwords.
DANGER!
Dangerindicatesanimminentlyhazardoussituation
which,ifnotavoided,willresultindeathorserious
injury.
WARNING!
Warningindicatesapotentiallyhazardoussituation
which,ifnotavoided,couldresultindeathorserious
injury.
CAUTION!
Cautionindicatesapotentiallyhazardoussituation
which,ifnotavoided,mayresultinpropertydamage
orminorinjuryorboth.
Givesusefultips,recommendationsandinformationfor
efficient,trouble-freeuse.
ThisproductcomplieswithDirective93/42/EECconcerning
medicaldevices.
ThelaunchdateofthisproductisstatedintheCE
declarationofconformity.
1.2IntendedUse
WARNING!
TheCheckO
2
Plusisforcheckingoxygen
concentratorsonly.
DONOTusetheCheckO
2
Plusforcontinuous
oxygenmonitoring.
TheCheckO
2
Plusisforuseonlybytrainedpersonnel.
TheCheckO
2
PlusOxygenAnalyzermeasuresoxygenconcentration
andflowusingultrasoundtechnologyandmeasurespressureusinga
piezoresistivesiliconpressuresensor.
TheCheckO
2
PlusOxygenAnalyzerisatoolusedtomeasure
oxygenpurity,flowandpressureattheoutletofanoxygen
concentrator.Itisnotintendedtobeusedbypatientswhoare
prescribedoxygen,norisitintendedtocontinuouslymonitoror
confirmoxygendeliverytoapatient.
TheCheckO
2
PlusOxygenAnalyzerisintendedtobeusedinan
environmentwhereoxygenconcentratorsarebeingservicedor
repaired.ThisincludesHospitals,NursingHomes,ExtendedCare
Facilities,PatientHomes,andRespiratoryDeviceServiceandRepair
Centers.
4
1176119-A
SystemOverview
2SystemOverview
2.1DescriptionandPrincipleofOperation
TheCheckO
2
Plusisanoxygenanalyzerdesignedtocheck
theoxygenconcentration,flowandoutletpressureofoxygen
concentrators.TheCheckO
2
Plusprovidesunparalleledperformance
andreliabilityfromitsadvanceddesignthatincludesthefollowing
featuresandoperationalbenefits:
Accurateoxygenmeasurements
Noin-fieldcalibrationrequired
ConvenientabilitytomeasurepressureinPSIorkPa
Durable,compactdesign
Large,easy-to-read,liquidcrystaldisplay(LCD)
Shielded,reinforcedsamplegasinletport
Longbatterylifewith2AAbatteries
Auto-offafter4minutes
Lowbatteryindication
Self-diagnostics
Easytoclean
2.2ComponentIdentification
A
LCDDisplay
D
GasSampleInlet
B
ModeButton
E
GasSampleOutlet
C
On/OffButton
F
BatteryDoor
1176119-A5
2.3SymbolGuide
ThefollowingsymbolsandsafetylabelsarefoundontheCheckO
2
Plus:
Authorized
representative
intheEuropean
Community
On/offbutton
Donotthrow
away.Follow
localguidelinesfor
disposal.
Modebutton
EvaluatedbyETL
(IntertekTesting
Laboratories)
Lowbattery
Manufacturer
Literper
minuteflow
Ingressprotection Poundsper
squareinch
Latexfree
Kilopascals
Serialnumber
Percent
Catalognumber GasSample
Inlet
Consult
accompanying
documents
GasSample
Outlet
Directcurrent
2.4ComponentDescription
31/2DigitDisplayTheLCDprovidesdirectreadoutofoxygen
concentration,gasflowandgaspressure.TheLCDalsodisplays
errorcodesasnecessary.
ON/OFFButtonTurnsthedeviceonoroff.
ModeButtonSwitchesbetweenmeasuringtheconcentration
ofgasproducedbyanoxygenconcentratorandpureoxygen(for
calibrationverification).
LowBatteryIndicatorIndicatesthevoltageofthebatteriesis
belownormaloperatinglevels.
LPMIlluminatednexttotheflowmeasurement.(notshown
whenincalibrationverification
kPAIndicatesthepressuremeasurementisinunitsofkilopascals.
PSIIndicatesthepressuremeasurementisinunitsofpounds
persquareinch.
“%”symbolIlluminatednexttotheconcentrationmeasurements.
GasSampleInletUsedtoreceivethegassample.
GasSampleOutletUsedasanoutletforthegassampleandas
atriggerforpressuremeasurementwhenoccluded.
GasSampleTubingUsedtoconnecttogassamplesources.
2.5IncludedwithYourUnit
UserManual
GasSampleTubing
SoftCover
61176119-A
Safety
3Safety
3.1GeneralGuidelines
WARNING!
Thissectioncontainsimportantinformationforthe
safeoperationanduseofthisproduct.
DONOTUSETHISPRODUCTORANYAVAILABLE
OPTIONALEQUIPMENTWITHOUTFIRST
COMPLETELYREADINGANDUNDERSTANDING
THESEINSTRUCTIONSANDANYADDITIONAL
INSTRUCTIONALMATERIALSUCHASUSER
MANUALS,SERVICEMANUALSORINSTRUCTION
SHEETSSUPPLIEDWITHTHISPRODUCTOR
OPTIONALEQUIPMENT.IFYOUAREUNABLE
TOUNDERSTANDTHEWARNINGS,CAUTIONS
ORINSTRUCTIONS,CONTACTAHEALTHCARE
PROFESSIONAL,DEALERORTECHNICAL
PERSONNELBEFOREATTEMPTINGTOUSETHIS
EQUIPMENT-OTHERWISE,INJURYORDAMAGE
MAYOCCUR.
ACCESSORIESWARNING
Invacareproductsarespecificallydesignedand
manufacturedforuseinconjunctionwithInvacare
accessories.Accessoriesdesignedbyother
manufacturershavenotbeentestedbyInvacareand
arenotrecommendedforusewithInvacareproducts.
DANGER!
TOREDUCETHERISKOFBURNS,
ELECTROCUTION,FIREORINJURYTO
PERSONS
Notforuseinanesthesiaapplicationsorformeasuring
oxygenconcentrationfromanysourcesotherthan
conventionaloxygenconcentrators.
Notforusewithinhalationagents.Operating
theCheckO
2
PlusPlusinflammableorexplosive
environmentsmayresultinfireorexplosion.
Notsuitableforuseinthepresenceofflammable
anestheticmixtures.
Oxygenrapidlyacceleratescombustion.Donot
smokewhileusingtheCheckO
2
Plusforchecking
oxygenconcentrators.
NOTforuseinanMRIenvironment.
1176119-A7
WARNING!
ImproperuseoftheCheckO
2
Pluscancauseinaccurate
oxygenreadingsleadingtoimpropertreatmentand/or
patientharm.Followtheproceduresoutlinedinthis
usermanual.
Usersmustbecomethoroughlyfamiliarwiththe
informationcontainedinthisUserManualbefore
use.Strictadherencetotheoperatinginstructions
isnecessaryforsafe,effectiveproductperformance.
Thisproductwillperformonlyasdesignedifoperated
inaccordancewiththemanufacturer’soperating
instructions.
DONOTusetheCheckO
2
Plustomeasurethe
oxygenconcentrationofaconcentratorwhenflowing
atrateslowerthanitsoptimalperformanceas
specifiedbytheconcentratormanufacturer;generally
4LPMorlessonconcentratorsthathaveamaximum
flowof10LPM,and1LPMorlessonconcentrators
thathaveamaximumflowof5LPM.
UseoftheCheckO
2
Plusneardevicesthatgenerate
electricalfieldsmaycauseerraticreadings.
IftheCheckO
2
Plusiseverexposedtoliquidsfrom
spillsorimmersion,immediatelyremovethebatteries
andletthedevicedrycompletely.Whendry,replace
thebatteriesandcheckforproperoperation.
WARNING!
DONOTautoclaveorexposetheCheckO
2
Plusto
hightemperatures(>60°C[140°F]).
DONOTuseethyleneoxidesterilization.
DONOTexposetheCheckO
2
Plustoirradiation,
vacuum,steam,orharshchemicals.
DONOTexposetheCheckO
2
Plustopressure
greaterthan50psi.Exposuretopressureabove50psi
couldcauseleaksinthedevicewhichmayadversely
affectperformanceinflowandpressurereadings.
RepairoralterationoftheCheckO
2
Plusbyanyone
otherthanaqualifiedtechniciancouldcausethe
producttofailtoperformasdesigned.
81176119-A
Safety
CAUTION!
ReplacethebatterieswithhighqualityAAAlkaline
orLithiumbatteries.DONOTuserechargeable
batteries.
Whennotinuseforperiodsgreaterthan30days
removethebatteriestoprotecttheCheckO
2
Plus
frompotentialbatteryleakage.
AvoiddroppingtheCheckO
2
Plustopreventdamage
whichmayadverselyaffectitsperformance.Ifdamage
tothedeviceissuspected,perform4.3Calibration
VerificationProcedure,page10.
AvoidforeignmatterentryintotheCheckO
2
Plus.
DONOTusetheCheckO
2
Plustochecka
concentratorwithahumidifierinplace.Humidity
coulddamagethedevice.
DONOTcheckaconcentratorwhileholdingthe
modebuttonorthereadingwillbeinaccurate.
Followingstorageinextremelyhotorcoldconditions,
allowthegastoflowthroughtheanalyzerlongenough
fortheinternalsensorstoreachthegasstream
temperature,orwaitfortheanalyzertoequilibrateto
roomtemperaturebeforeuse.
3.2Disposal
Thisproducthasbeensuppliedfromanenvironmentallyaware
manufacturerthatcomplieswiththeWasteElectricalandElectronic
Equipment(WEEE)Directive2002/96/CE.
Thisproductmaycontainsubstancesthatcouldbeharmfultothe
environmentifdisposedofinplaces(landfills)thatarenotappropriate
accordingtolegislation.
Pleasebeenvironmentallyresponsibleandrecyclethisproduct
throughyourrecyclingfacilityatitsendoflife.
Thebatteriesandcircuitboardarenotsuitableforregulartrash
disposal.
1176119-A9
4OperatingInstructions
4.1Oxygen,FlowandPressureMeasurement
Tocheckoxygenconcentration,flowandpressureofagassample
fromaconcentrator:
1.Connectthegassampletubingtothegassampleinletofthe
CheckO
2
Plus.
2.Attachtheotherendofthegassampletubingtotheoxygen
concentrator.
3.InitiatetheflowofgastotheCheckO
2
Plusatarateof
1-10litersperminute(2litersperminuteisrecommended).
Ensuretheconcentrator’soutputisstablepertheconcentrator
manufacturer’srecommendations.
4.TurnontheCheckO
2
Plus.
5.Allowtheoxygenreadingtostabilizeforapproximately10
secondsbeforereadingtheoxygenconcentrationandflow.
6.Tocheckpressure,coverthegassampleoutletwiththumbor
fingerwhilegasisflowing.
7.Wait5secondsforthedisplaytoreadpressure.
DONOTholdthemodebuttonwhilecheckinga
concentratororthereadingwillbeinaccurate.
4.2SwitchingPressureUnitsofMeasure
TheCheckO
2
PluscanmeasurepressureinPSIorkPa.TheCheck
O
2
PlusisfactorysettomeasureinPSI.ToswitchtokPa:
1.Usinga#1Phillipsscrewdriverloosenthebatterydoorscrew
andremovethebatterydoor.
2.Toggletheswitchinsidethebatterycompartment.
3.Replacethebatterydoorandtightenthebatterydoorscrew.
4.3CalibrationVerificationProcedure
Acalibrationverificationmodeisprovidedtoverifythatthe
CheckO
2
Plusisfunctioningproperly.Toperformthecalibration
verification:
1.TurnontheCheckO
2
Plus.
2.Connectasourceofpureoxygen(99.95%)tothegassample
inlet
3.Flow2–5LPMofgasintotheCheckO
2
Plus.Ensurethatthegas
flowingtotheCheckO
2
Plusisatastabletemperature.
4.Pressandholdthemodebutton.Whileholdingthemode
button,thegasmeasurementshouldreadbetween98.5and
101.5%oxygen.Ifthegasmeasurementisnotwithinthis
range,callCustomerService.Calibrationverificationmodeis
indicatedby“CAL”and“VER”flashingonscreenbeneaththe
gasmeasurement.
4.4FactorsInfluencingAccurateReadings
EffectsofTemperature
TheCheckO
2
Pluscompensatesfortemperatureandwillperform
withinspecificationsthroughouttheoperatingtemperature
range.However,takingmeasurementsduringrapidchangesingas
temperatureshouldbeavoided.
EffectsofHumidity
TheCheckO
2
Plushasahumiditysensortodetectandcompensate
forthehumidityofgasenteringthedevice.However,highlevels
(condensing)ofhumiditycanaffecttheaccuracyandreliabilityofthe
CheckO
2
Plus.Topreventpossibledamage:
Avoidusageinenvironmentsofgreaterthan95%relativehumidity
DONOTusethisdeviceinabreathingcircuit
DONOTbreatheorblowintotheCheckO
2
Plus
101176119-A
OperatingInstructions
EffectsofOtherGases
TheCheckO
2
Plusisdesignedtomeasuretwodifferenttypesof
gasmixtures:
Oxygen,nitrogenandargonfromoxygenconcentrators
Pureoxygenduringcalibrationverificationmode
Anyotherconcentrationsorcombinationsofgaseswillcausethe
CheckO
2
Plustomeasureoxygenconcentrationincorrectly.
EffectsofLowFlow
Oxygenconcentratorsfunctionontheprincipleofremovingnitrogen
gasfromair,leavingconcentratedoxygenandargonataspecific
oxygentoargonratio.Thisoperatingprinciplemaybealteredwhen
concentratorsaresettoflowatthelowendoftheiroperational
range.Atlowflowstheymayoutputalowoxygenconcentration,
e.g.85%to91%,forreasonsotherthanhighnitrogen,possiblydue
toanincreaseinargoncontent.TheCheckO
2
Plusrequiresthat
theratioofoxygentoargonremainconstantinordertoguarantee
anaccuracyof+/-1.5%oxygen.
DONOTusetheCheckO
2
Plustomeasuretheoxygen
concentrationofaconcentratorwhenflowingatrateslower
thanitsoptimalperformanceasspecifiedbytheconcentrator
manufacturer;generally4LPMorlessonconcentratorsthathave
amaximumflowof10LPM,and1LPMorlessonconcentrators
thathaveamaximumflowof5LPM.
1176119-A
11
5ErrorCodes
5.1ErrorCodes
TheCheckO
2
Plushasselfdiagnosticfeaturesbuiltintothesoftware
todetectfaultyreadingsoutsideofnormaloperatingranges.The
codes,descriptionsandrecommendedactionsare:
E01:OxygenmeasurementoutofrangeHi(102.0%calculated
byalgorithm).
RecommendedAction:VerifythattheCheckO
2
Plusisbeingused
inthecorrectmode(ConcentratororCalibrationVerification
mode).Iferrorcoderepeats;performacalibrationverification.If
errorcoderepeatsagain;CallServiceProvider.
E02:OxygenmeasurementoutofrangeLow(-2.0%calculated
byalgorithm).
RecommendedAction:VerifythattheCheckO
2
Plusisbeingused
inthecorrectmode(ConcentratororCalibrationVerification
mode).Iferrorcoderepeats;performacalibrationverification.If
errorcoderepeatsagain;CallServiceProvider.
E03:Devicememorycorruptormissing.
RecommendedAction:CallServiceProvider.
E04:Signalreadingnotstable.
RecommendedAction:CallServiceProvider.
E05:PressuremeasurementoutofRangeHi(50PSI).
RecommendedAction:Checkthepressureonaknowngassource
pressure.Iferrorcoderepeats;CallServiceProvider.
E06:OutsideofoperatingtemperatureHi(40°C).
Recommendedaction:TheCheckO
2
Plusistoohot,coolthe
deviceclosertoroomtemperaturebeforeuse.
E07:OutsideofoperatingtemperatureLow(15°C).
Recommendedaction:TheCheckO
2
Plusistoocold,warmthe
deviceclosertoroomtemperaturebeforeuse.
E08:Deviceselfcheckfounderror.
RecommendedAction:Removeandreplacethebatteries.Iferror
coderepeats;CallServiceProvider.
12
1176119-A
ChangingtheBatteries
6ChangingtheBatteries
6.1BatteryReplacementProcedure
Batteriesshouldbechangedwhenthe
iconilluminates.The
iconwillremainlituntilthebatteriesarechanged.Ifthebattery
powerlevelistoolowtheCheckO
2
Pluswillnotpoweronuntil
thebatteriesarechanged.
1.Usinga#1PhillipsscrewdriverloosenthebatterydoorscrewA
andremovethebatterydoorB.
2.Removethebatteries.
3.Insertnewbatteriesensuringcorrectpolarity.DONOTuse
rechargeablebatteries.
4.Replacethebatterydoorandtightenthebatterydoorscrew.
5.IftheCheckO
2
Plusdoesnotpoweronwhendoneverifythe
batteriesareinstalledcorrectlyandthatthebatteriesarefresh.
1176119-A13
7CleaningandMaintenance
7.1Cleaning
CAUTION!
Usecautiontopreventanyfluidfromenteringthe
CheckO
2
Plus.
DONOTsoakorimmersetheCheckO
2
Plusinfluid.
DONOTautoclaveorexposetheCheckO
2
Plusto
ethyleneoxidesterilization.
WipedowntheexteriorsurfacesoftheCheckO
2
Pluswithamoist
clothandmildhandordishsoap(pH6–8).
7.2Maintenance
ReplacethebatterieswithhighqualityAAAlkalineorLithium
batteries.DONOTuserechargeablebatteries.
Whennotinuseforperiodsgreaterthan30days,removethe
batteriestoprotecttheunitfrompotentialbatteryleakage.
StoretheCheckO
2
Plusbetween–15°Cand60°C(5°F
140°F)
14
1176119-A
TechnicalData
8TechnicalData
8.1ProductParameters
OXYGEN
Oxygen
Measurement
Range:(froma
concentrator)
20.9-96%
Oxygen
Measurement
Accuracy:
±1.5%offullscaleatconstanttemperature
andoptimalflow*
Oxygen
Measurement
Resolution:
0.1%Oxygen
SeeEffectsofLowFlow,page11ofthisoperatingmanual
forinformationontheeffectsoflowflow.
FLOW
FlowMeasurement
Range:
0-10LPM
FlowMeasurement
Accuracy:
±0.2LPM
FlowMeasurement
Resolution:
0.1LPM
PRESSUREPSI
KPA
Pressure
MeasurementRange:
0.5-503.4-344
Pressure
Measurement
Accuracy:
±0.5%±0.5%
Pressure
Measurement
Resolution:
0.10.1upto199,1
from200to344
ResponseTime:
17seconds
Warm-upTime:<1second
Operating
Temperature:
59°F-104°F(15°C-40°C)
Storage
Temperature:
F-140°F(-15°C-60°C)
Pressure:
800-1000mBars
Humidity:
0-95%(non-condensing)
Power
Requirements:
2-AAAlkalinebatteries(2x1.5volts)
BatteryLife:1,100hours(16,500readcycles)
LowBattery
Indication:
“LowBattery”icondisplayedonLCD
Dimensions:
3.16”x5.10”x1.04”(80.3mmx129.5
mmx26.4mm)
Weight:0.4lbs(181grams)
CLASSIFICATIONS
Protectionagainst
electricalshock:
Internallypoweredequipment
Protectionagainst
water:
Modeofoperation:Continuous
Sterilization:See7.1Cleaning,page14.
Flammable
anaestheticmixture:
Notforuseinpresenceofflammable
anaestheticmixtures
Powerspecification:1.8-3.2V 32mW10mA
1176119-A15
9Warranty
9.1WarrantyNorthAmerica
PLEASENOTE:THEWARRANTYBELOWHAS
BEENDRAFTEDTOCOMPLYWITHFEDERALLAW
APPLICABLETOPRODUCTSMANUFACTUREDAFTER
JULY4,1975.
Thiswarrantyisextendedonlytotheoriginalpurchaser/userofour
products.
Thiswarrantygivesyouspecificlegalrightsandyoumayalsohave
otherlegalrightswhichvaryfromstatetostate.
Invacarewarrantsthisproducttobefreefromdefectsinmaterials
andworkmanshipforthreeyearsfortheoriginalpurchaser.If
withinsuchwarrantyperiodanysuchproductshallbeproventobe
defective,suchproductshallberepairedorreplaced,atInvacare’s
option.Thiswarrantydoesnotincludeanylabororshippingcharges
incurredinreplacementpartinstallationorrepairofanysuch
product.Invacare’ssoleobligationandyourexclusiveremedyunder
thiswarrantyshallbelimitedtosuchrepairand/orreplacement.
Forwarrantyservice,pleasecontactthedealerfromwhomyou
purchasedyourInvacareproduct.Intheeventyoudonotreceive
satisfactorywarrantyservice,pleasewritedirectlytoInvacareatthe
addressonthebackpage.Providedealer’sname,address,model
number,dateofpurchase,indicatenatureofthedefectand,ifthe
productisserialized,indicatetheserialnumber.
InvacareCorporationwillissueareturnauthorization.Thedefective
unitorpartsmustbereturnedforwarrantyinspectionusingthe
serialnumber,whenapplicable,asidentificationwithinthirty(30)
daysofreturnauthorizationdate.DONOTreturnproductstoour
factorywithoutourpriorconsent.C.O.D.shipmentswillberefused;
pleaseprepayshippingcharges.
LIMITATIONSANDEXCLUSIONS:THEWARRANTYSHALL
NOTAPPLYTOPROBLEMSARISINGFROMNORMAL
WEARORFAILURETOADHERETOTHEENCLOSED
INSTRUCTIONS.INADDITION,THEFOREGOINGWARRANTY
SHALLNOTAPPLYTOSERIALNUMBEREDPRODUCTSIF
THESERIALNUMBERHASBEENREMOVEDORDEFACED;
PRODUCTSSUBJECTEDTONEGLIGENCE,ACCIDENT,
IMPROPEROPERATION,MAINTENANCEORSTORAGE;OR
PRODUCTSMODIFIEDWITHOUTINVACARE’SEXPRESS
WRITTENCONSENTINCLUDING,BUTNOTLIMITEDTO:
MODIFICATIONTHROUGHTHEUSEOFUNAUTHORIZED
PARTSORATTACHMENTS:PRODUCTSDAMAGEDBYREASON
OFREPAIRSMADETOANYCOMPONENTWITHOUTTHE
SPECIFICCONSENTOFINVACARE;PRODUCTSDAMAGED
BYCIRCUMSTANCESBEYONDINVACARE’SCONTROL;
PRODUCTSREPAIREDBYANYONEOTHERTHANAN
INVACAREDEALER,SUCHEVALUATIONSHALLBESOLELY
DETERMINEDBYINVACARE.
THEFOREGOINGEXPRESSWARRANTYISEXCLUSIVEANDIN
LIEUOFANYOTHEREXPRESSWARRANTIESWHATSOEVER,
WHETHEREXPRESSORIMPLIED,INCLUDINGTHEIMPLIED
WARRANTIESOFMERCHANTABILITYANDFITNESSFOR
APARTICULARPURPOSEANDTHESOLEREMEDYFOR
VIOLATIONSOFANYWARRANTYWHATSOEVER,SHALLBE
LIMITEDTOREPAIRORREPLACEMENTOFTHEDEFECTIVE
PRODUCTPURSUANTTOTHETERMSCONTAINED
HEREIN.THEAPPLICATIONOFANYIMPLIEDWARRANTY
WHATSOEVERSHALLNOTEXTENDBEYONDTHEDURATION
OFTHEEXPRESSWARRANTYPROVIDEDHEREIN.INVACARE
SHALLNOTBELIABLEFORANYCONSEQUENTIALOR
INCIDENTALDAMAGESWHATSOEVER.
THISWARRANTYSHALLBEEXTENDEDTOCOMPLYWITH
STATE/PROVINCIALLAWSANDREQUIREMENTS.
161176119-A
Warranty
9.2WarrantyEurope
Invacare®guaranteesthattheirproductsarefreefromdefectsand
arefullyfunctional.Thewarrantycoversallfaultsanddefectswhich
areverifiablyattributabletofaultyconstruction,substandardmaterials
orpoorworkmanship.Warrantyclaimsagainstthemanufacturermay
onlybemadebythedistributorandnotbytheuseroftheproduct.
Thewarrantydoesnotcovernormalwearandtear,the
consequencesofimproperhandlingordamage,poormaintenance
andincorrectassemblyorcommissioningbythepurchaserorathird
personorfaultswhichareattributabletocircumstancesbeyond
ourcontrol.Wearingpartsarenotcoveredbytheguarantee.The
warrantyisvoidedifmodificationsaremadetotheproductwhich
werenotauthorisedandnotperformedbythespecialistdealeror
ifinappropriateaccessoriesorsparepartsareused.Thewarranty
doesnotcoverconsequentialcostsarisingfromtherectificationof
defectssuchasfreightandtravelexpenses,labourcosts,feesetc.
Thetermofthewarrantyis24month.
Furthermore,thetermsandconditionsarepartofthegeneralterms
andconditionsparticulartotheindividualcountriesinwhichthis
productissold.
1176119-A17
Notes
Sommaire
CemanuelDOITêtreremisàl'utilisateurduproduit.Lirecemanuel
AVANTd'utiliserceproduit,etleconserverencasdebesoin.
1Généralités...................................20
1.1Symboles.................................20
1.2Utilisationconforme.........................20
2Aperçudusystème.............................21
2.1DescriptionetPrincipedefonctionnement........21
2.2Identificationdescomposantes.................21
2.3Guidedessymboles........................22
2.4Descriptiondescomposantes.................22
2.5L’emballagecomprend.......................22
3Sécurité......................................23
3.1Misesengarde.............................23
3.2Elimination...............................25
4Moded'emploi................................26
4.1Mesuredudébit,delapressionetdela
concentrationd’oxygène.....................26
4.2Passaged’uneunitédemesuredepressionàune
autré....................................26
4.3Procéduredecontrôledelacalibration..........26
4.4Facteursinfluençantl'obtentionderésultats
exacts...................................26
Effetsdelatempérature......................26
Effetsdel’humidité.........................27
Autresgaz................................27
Effetsd’undébitfaible.......................27
5Codesd'erreur................................28
5.1Codesd’erreur............................28
6Remplacementdespiles........................29
6.1Procédurederemplacementdespiles............29
7Nettoyageetentretien.........................30
7.1Nettoyage................................30
7.2Entretien.................................30
8Caractéristiquestechniques.....................31
8.1ParamètresCaractéristiquesDuProduit..........31
9Garantie.....................................32
9.1GarantielimitéeAmériqueduNord............32
9.2Garantie.................................33
1Généralités
1.1Symboles
Lesmotsdesignalisationserventàindiquerdesdangersoupratiques
dangereusespouvantrésulterendesblessuresoudesdommages
matériels.Voirlesinformationsci-dessouspourladéfinitiondes
motsdesignalisation.
DANGER!
Dangerindiqueunesituationdangereuseimminente
qui,siellen'estpasévitée,peutentraînerdegraves
blessures.
AVERTISSEMENT!
Avertissementindiqueunesituationpotentiellement
dangereusesiellen’estpasévitéeetpeutrésulter
danslamortoudesblessuresgraves.
ATTENTION!
Attentionindiqueunesituationpotentiellement
risquéequi,siellen'estpasévitée,peutentraînerdes
dégâtspersonnelsoudeslésionsmineures.
Conseils,recommandationsetinformationsutilespourune
utilisationefficaceetsanssoucis.
CeproduitestconformeàlaDirective93/42/CEEsurles
dispositifsmédicaux.
Ladatedelancementdeceproduitestindiquéedansla
déclarationdeconformitéCE.
1.2Utilisationconforme
AVERTISSEMENT!
LeCheckO
2
Plussertàcontrôlerlesconcentrateurs
d’oxygèneseulement.
NEPASutiliserleCheckO
2
Pluspourlasurveillance
continuedel’oxygène.
LeCheckO
2
Plusnedoitêtreutiliséquepardupersonnelqualifié.
L´analyseurd´oxygèneCheckO
2
Plusmesureledébitetla
concentrationd´oxygèneenutilisantlatechnologieultrasonique,ainsi
quelapressiondel´oxygèneenutilisantuncapteurdepressionen
silicumpiézorésistif.
L’analyseurd’oxygèneCheckO
2
Plusestunoutilutilisépourmesurer
lapureté,ledébitetlapressiondel’oxygèned’unconcentrateur
d’oxygène.L’analyseurd’oxygèneCheckO
2
Plusn’estpasconçu
pourêtreutiliséparlespatientsauxquelsilaétéprescritde
l’oxygène.Demême,iln’estpasconçupourlasurveillancecontinue
oulaconfirmationd’alimentationenoxygèned’unpatient.
L’analyseurd’oxygèneCheckO
2
Plusestconçupourêtreutilisédans
unenvironnementlesconcentrateursd’oxygènesontentretenus
ouréparés.Ceslieuxcomprennentleshôpitaux,lesmaisonsde
retraite,lesétablissementsdesoinsprolongés,ledomiciledes
patientsetlescentresderéparationetd’entretiendesappareils
respiratoires.
201176119-A
Aperçudusystème
2Aperçudusystème
2.1DescriptionetPrincipedefonctionnement
LeCheckO
2
Plusestunanalyseurd’oxygèneconçupourvérifier
ledébit,lapressiondesortieetlaconcentrationd’oxygènedes
concentrateursd’oxygène.LeCheckO
2
Plusoffredesperformances
etunefiabilitéinégaléesgrâceàsaconceptiondepointequiinclutles
fonctionnalitésetlesavantagesopérationnelssuivants:
Unemesureprécisedutauxd’oxygène.
Lecalibrageparl´utilisateurn´estpasrequis.
LapossibilitédemesurerlapressionenPSIouenkPa.
Uneconceptiondurableetcompacte.
Unaffichageàcristauxliquides(ACL)degrandetailleetfacileàlire.
Unportd’entréedeséchantillonsdegazblindéetrenforcé.
Unelongueduréed’utilisationavec2pilesAA.
Unarrêtautomatiqueaprès4minutes.
Uneindicationdepilefaible.
Lesauto-diagnostics.
Unnettoyagefacile.
2.2Identificationdescomposantes
A
Écranàcristaux
liquide
D
Entréede
l’échantillonde
gaz
B
Boutonde
mode
E
Sortiede
l’échantillonde
gaz
C
Boutonde
marche/arrêt
F
Couvercledu
compartiment
despiles
1176119-A
21
2.3Guidedessymboles
Lesétiquettesdesécuritéetlessymbolessuivantsfigurentsurle
CheckO
2
Plus:
Représentant
autorisédans
lacommunauté
européenne
Boutonde
marche/arrêt
Nepasjeter.Suivre
lesdirectiveslocales
pourl’élimination
Boutonde
mode
ÉvaluéparETL
(IntertekTesting
Laboratories)
Pilefaible
Fabricant Débitenlitre
parminute
Indicedeprotection Livrespar
poucecarré
Sanslatex
Kilopascals
Numérodesérie Pourcentage
Numérodecatalogue Entréede
l’échantillon
degaz
Veuillezconsulter
lesdocuments
d’accompagnement
Sortiede
l’échantillon
degaz
Courant
continu
2.4Descriptiondescomposantes
31/2chiffresàl’écranL’écranàcristauxliquidepermetune
lecturedirectedelaconcentrationd’oxygène,dudébitetdela
pressiondugaz.L’écranàcristauxliquideafficheégalementlescodes
d’erreursinécessaire.
Boutondemarche/arrêtÉteintouallumel’appareil.
BoutondemodeBasculeentrelamesuredelaconcentration
degazproduitparunconcentrateurd’oxygèneetdel’oxygènepur
(pourvérifierlacalibration).
IndicateurdepilefaibleIndiquequelatensiondespilesesten
dessousdesniveauxdefonctionnementnormal.
LPMIlluminéàcôtédelamesurededébit.(Nonillustréenmode
devérificationdelacalibration.)
kPAIndiquequelamesuredelapressionestexpriméeen
kilopascals.
PSIIndiquequelamesuredelapressionestexpriméeenlivres
parpoucecarré.
Symbole«%»Illuminéàcôtédelamesuredelaconcentration.
Entréedel’échantillondegazUtiliséepourrecevoir
l’échantillondegaz.
Sortiedel’échantillondegazUtiliséecommesortiepour
l’échantillondegazetcommeundéclencheurpourlamesuredela
pressionlorsd’uneobstruction.
Tubuluredel’échantillondegazPermetdeconnecterles
sourcesd’échantillondegaz.
2.5L’emballagecomprend
Manueld’utilisation
Tubuluredel’échantillondegaz
Couverclesouple
22
1176119-A
Sécurité
3Sécurité
3.1Misesengarde
AVERTISSEMENT!
Cechapitrecontientdesinformationsimportantes
concernantlefonctionnementetlʹutilisationsans
dangerdeceproduit.
NEPASUTILISERCEPRODUIToutoutautre
produitoptionnelsansavoiraupréalablelu
etcompriscesinstructionscomplémentaires
commelesmanuelsd'utilisation,lesmanuelsde
maintenanceetlanoticed'instructionavecle
produitoutoutéquipementoptionnel.ENCAS
D'INCOMPREHENSIONDESMISESENGARDE,
DESMESSAGESD'AVERTISSEMENTouDES
INSTRUCTIONS,veuillezcontacterunprofessionnel
desanté,votredistributeuroulepersonneltechnique
avantdetenterd'utilisercetappareil-lecaséchéant,
ILYAUNRISQUEDEBLESSURECORPORELLEou
deDOMMAGEMATERIEL.
AVERTISSEMENTSURLESACCESSOIRES
LesproduitsInvacaresontconçusetfabriqués
spécialementpouruneutilisationencombinaison
aveclesaccessoiresInvacare.Lesaccessoiresconçus
pard’autresfabricantsn’ontpasététestéspour
uneutilisationparInvacareetnesontdoncpas
recommandéspouruneutilisationaveclesproduits
Invacare.
DANGER!
Pourréduirelerisquedebrûlures,
d’electrocution,d’incendieoudedommages
corporels
Nel’utilisezpasdanslesapplicationsd’anesthésieou
pourmesurerdesconcentrationsd’oxygèneàpartir
detoutesautressourcesquelesconcentrateurs
d’oxygèneconventionnels.
Nel’utilisezpasavecdesagentsd’inhalation.Utiliserle
CheckO
2
Plusdansdesenvironnementsinflammables
ouexplosifspeutentraînerunincendieouune
explosion.
Nepasutiliserenprésencedemélanges
d’anesthésiquesinflammables.
L'oxygèneestuncomburantetaccélèrerapidementla
combustion.NEFASFUMERenutilisantleCheckO
2
Pluspendantlavérificationdel'appareil.
Nepasutiliserdansunenvironnementd’IRM.
1176119-A23
AVERTISSEMENT!
UneutilisationincorrecteduCheckO
2
Pluspeutcauser
desmesuresd’oxygèneinexactesquipourraientconduire
àuntraitementinadéquatouàdesconséquences
néfastespourlepatient.Suivezlesprocéduresdécrites
danscemanuel.
Lesutilisateursdoiventbiensefamiliariseravec
lesinformationscontenuesdansceManuelde
fonctionnementavantdeprocéder.Lestrictrespect
dumoded’emploiestnécessairepourassurer
lasécuritéetl’efficacitéduproduit.Ceproduit
fonctionnecommeprévuuniquementlorsqu’ilest
utiliséconformémentaumoded’emploidufabricant.
NEPASutiliserle’CheckO
2
Pluspourmesurer
laconcentrationd’oxygèned’unconcentrateur
d’oxygènelorsqueledébitestinférieurparrapport
àlaperformanceoptimalecommespécifiéparle
fabricantduconcentrateur(généralement4l/min
oumoinssurlesconcentrateursquiontundébit
maximumde10l/minet1l/minoumoinspourles
concentrateursayantundébitmaximumde5l/min).
L’utilisationdul’CheckO
2
Plusprèsdedispositifsqui
génèrentdeschampsélectriquespourraitcauserdes
lecturesirrégulières.
AVERTISSEMENT!
SileCheckO
2
Plusestexposéàdesliquides
provenantdedéversementsoud’uneimmersion,
retirezimmédiatementlespilesetlaissezl’appareil
séchercomplètement.Unefoissec,replacezlespiles
àl’intérieuretvérifiezsonbonfonctionnement.
NePASmettrel’appareildansl’autoclave;ne
soumettezPASnonplusleCheckO
2
Plusàdes
températuresélevées(>60°C[140°F]).
NerecourezPASàlastérilisationàl’oxyded’éthylène.
NEPASexposerleCheckO
2
Plusauxradiations,au
vide,àlavapeurouàdesproduitschimiquesdurs.
N’exposezPASleCheckO
2
Plusàunepression
supérieureà344kPa.L´expositionàunepression
supérieureà344Kpapourraitcauserdesfuitesdans
ledispositifcequipeutaffecternégativementles
performancesauniveaududébitetdelapression
d´oxygène.
Laréparationoulamodificationdul’CheckO
2
Plus
parunepersonneautrequ’unreprésentantduservice
autoriséparMaxtecpourraitfaireensortequele
produitnefonctionnepascommeprévu.
24
1176119-A
Sécurité
ATTENTION!
RemplacezlespilespardespilesAAalcalinesouau
lithiumdehautequalité.NePASutiliserPASdepiles
rechargeables.
Lorsquel’appareiln’estpasutilisépendantdes
périodesdeplusde30jours,enlevezlespilespour
protégerleCheckO
2
Plusd’unefuitepotentielle.
ÉvitezdelaissertomberleCheckO
2
Pluspour
prévenirdesdommagesquipourraientaffecterses
performances.Sivoussuspectezquel´appareilaitsubi
desdommages,effectuez4.3Procéduredecontrôle
delacalibration,page26
.
Éviterl’entréedematièresétrangèresdansleCheck
O
2
Plus.
NEPASutiliserleCheckO
2
Pluspourvérifierun
concentrateuravecunhumidificateurenplace.
L’humiditéd’unhumidificateurpeutendommager
l’appareil.
NEPASvérifierunconcentrateurenappuyantsurle
bouton«MODE»sinonlalectureserainexacte.
Àlasuited’unstockagedansdesconditions
extrêmementchaudesoufroides,laisserunpassage
dedébitdegazsuffisantpourquelescapteurs
internesatteignentlatempératuredugazouattendre
quelatempératuredel’analyseurs’équilibreavecla
températureambianteavantl’utilisation.
3.2Elimination
Ceproduitaétélivréparunfabricantsoucieuxdelʹenvironnement
etconformeàladirective2002/96/CEsurlamiseaurebutdes
équipementsélectroniquesetélectriquesWEEE.
Ceproduitestsusceptibledecontenirdessubstancespotentiellement
nocivespourl’environnements’ilestmisaurebutdansdesendroits
(décharges)nonconformesàlalégislationenvigueur.
Mercidepréserverl’environnementetderecyclerceproduitenfin
devieauprèsdevotrestationderecyclagelocale.
L’éliminationaveclesdéchetsordinairesn’estpasappropriéepour
lespilesetlecircuitélectronique.
1176119-A25
4Moded'emploi
4.1Mesuredudébit,delapressionetdela
concentrationd’oxygène
Pourvérifierledébit,lapressionetlaconcentrationenoxygèned’un
échantillondegazprovenantd’unconcentrateur:
1.Connectezlatubuluredel’échantillondegazàl’entréede
l’échantillondegazduCheckO
2
Plus.
2.Branchezl’autreextrémitédelatubuluredel’échantillondegaz
auconcentrateurd’oxygène.
3.InitiezlefluxdegazversleCheckO
2
Plusàundébitde1
à10litresparminute(undébitde2litresparminuteest
recommandé).Assurez-vousqueledébitduconcentrateursoit
stableselonlesrecommandationsdufabricantduconcentrateur.
4.AllumezleCheckO
2
Plus.
5.Laissezlamesuresestabiliserpendantenviron10secondesavant
delireledébitetlaconcentrationenoxygène.
6.Pourvérifierlapression,couvrezlaprised’échantillondegaz
aveclepouceouundoigtpendantquelegazs’écoule.
7.Attendez5secondespourquel’affichageaffichelapression.
NEPASappuyersurlebouton«MODE»pendantla
vérificationd’unconcentrateursinonlalecturesera
inexacte.
4.2Passaged’uneunitédemesuredepressionà
uneautré
LeCheckO
2
PluspeutmesurerlapressionenPSIoukPa.LeCheck
O
2
PlusestrégléenusinepourmesurerenPSI.PourbasculerenkPa:
1.Àl’aided’untourneviscruciforme1,dévissezlavisdu
compartimentdespilesetretirezlecouvercle.
2.Poussezl’interrupteuràl’intérieurducompartimentdespiles.
3.Remettezlecouvercleducompartimentdespilesetserrezlavis.
4.3Procéduredecontrôledelacalibration
Lemodedevérificationdelacalibrationestprévupourvérifier
queleCheckO
2
Plusfonctionnecorrectement.Poureffectuerle
contrôledelacalibration:
1.AllumezleCheckO
2
Plus.
2.Connectezunesourced’oxygènepur(99,95%)àl’entréede
l’échantillondegaz.
3.RéglezledébitdugazversleCheckO
2
Plusentre2et5LPM.
Assurez-vousquelegazquicirculedansleCheckO
2
Plusestà
unetempératurestable.
4.Appuyezsurleboutondemodeetmaintenez-leenfoncé.
Laconcentrationdevraitsesituerentre98,5%et101,5%
d’oxygène.Silamesuredeconcentrationnesesituepasdans
cettefourchette,appelezleserviceàlaclientèle.Lemodede
contrôledelacalibrationestindiquéparleslettres«CAL»et«
VER»quiclignotentàl’écransouslamesure.
4.4Facteursinfluençantl'obtentionderésultats
exacts
Effetsdelatempérature
LeCheckO
2
Plus’adapteauxchangementsdetempérature
etfonctionneraselonlesspécificationssurtoutelaplagede
températuresdefonctionnement.Toutefois,laprisedemesuresau
coursdechangementsrapidesdelatempératuredesgazdoitêtre
évitée.
261176119-A
Moded'emploi
Effetsdel’humidité
LeCheckO
2
Plusdisposed’uncapteurd’humiditépour
mesurerl’humiditédesgazentrantdansledispositifets’ajuster
enconséquence.Toutefois,desniveauxélevésd’humidité
(condensation)peuventaffecterlaprécisionetlafiabilitéduCheck
O
2
Plus.Pourévitertoutdommagepossible:
Évitezl’utilisationdansdesenvironnementscontenantune
humiditérelativedeplusde95%.
N’utilisezPAScetappareildansuncircuitrespiratoire.
NerespirezounesoufflezPASdansleCheckO
2
Plus.
Autresgaz
LeCheckO
2
Plusestconçupourmesurerdeuxtypesdemélanges
degaz:
Unmélanged’oxygène,d’azoteetd’argonprovenantdes
concentrateursd’oxygène.
Del’oxygènepurpendantlemodedecontrôledelacalibration.
Toutesautresconcentrationsoucombinaisonsdegazaurontpour
conséquencequeleCheckO
2
Plusmesureralaconcentrationen
oxygènedemanièreincorrecte.
Effetsd’undébitfaible
Lesconcentrateursd´oxygènefonctionnentenenlevantlenitrogène
del´airetennelaissantquel´oxygèneetl´argondansune
proportionbiendéterminée.Ceprincipedefonctionnementpeut
êtrealtéréquandlesconcentrateurssontutilisésdansdesconditions
lesdébitsnecorrespondentpasauminimumrecommandé
parlefabricant.Afaiblesdébits,ilspeuventafficherdefaibles
concentrationsenoxygèneex.85%à91%,pasnécessairementà
caused´uneforteconcentrationennitrogène,maisplutôtàcause
d´uneaugmentationdelaconcentrationenargon.Leratiooxygène/
argondoitabsolumentresterconstantafinqueleCheckO
2
Plus
puissegarantirunefiabilitéetuneexactitudedesrésultatsde+/-
1.5%d´oxygène.
NepasutiliserleCheckO
2
Pluspourmesurerlaconcentrationen
oxygèned´unconcentrateurquandlesdébitsnecorrespondent
pasàceuxrequisparlefabricant.Engénéral,nepasmesurer
laconcentrationeuoxygéneámoinsde4LPMlorsqueledébit
maximumatteintles10LPM.Nepasmesurerlaconcentrationá
moinsde1LPMpourundébitmaximumde5LPM.
1176119-A27
5Codesd'erreur
5.1Codesd’erreur
LeCheckO
2
Pluscontientunefonctiond’auto-diagnosticintégrée
danslelogicielpourdétecterleslectureserronéesendehorsdes
plagesdefonctionnementnormales.Lescodes,lesdescriptionset
lesactionsrecommandéessont:
E01:lamesuredel’oxygèneestsupérieureàlalimite(102,0
%,calculéeparalgorithme).Actionrecommandée:vérifiezque
leCheckO
2
Plussoitutilisédanslebonmode(concentrateurou
modedecontrôledelacalibration).Silecoded’erreurserépète,
effectuezuncontrôledelacalibrationselonlasection4.3dece
manuel.Silecoded’erreurserépèteànouveau,contactezle
serviceclients.
E02:lamesuredel’oxygèneestinférieureàlalimite(-2,0
%,calculéeparalgorithme).Actionrecommandée:vérifiezque
leCheckO
2
Plussoitutilisédanslebonmode(concentrateur
oumodedevérificationdelacalibration).Silecoded’erreurse
répète,effectuezuncontrôledelacalibrationselonlasection4.3
decemanuel.Silecoded’erreurserépèteànouveau,contactez
leserviceclients.
E03:lamémoiredel’appareilestendommagéeoumanquante.
Actionrecommandée:renvoyerleCheckO
2
Plusaufabricant
pouruneréparationenusine.
E04:lalecturedusignaln’estpasstable.Actionrecommandée:
renvoyerleCheckO
2
Plusaufabricantpouruneréparationen
usine.
E05:mesuredelapressionhorslimite(50PSI).Action
recommandée:vérifiezlapressiond’unesourcedegazdontla
pressionestconnue.Silecoded’erreurserépète,contactezle
serviceclients.
E06:températuredefonctionnementtropélevée(40°C).
Actionrecommandée:leCheckO
2
Plusesttropchaud,laissez
l’appareilserefroidirjusqu’àcequ’ils’approchedelatempérature
ambianteavantutilisation.
E07:températuredefonctionnementtropbasse(15°C).
Actionrecommandée:leCheckO
2
Plusesttropfroid,réchauffez
l’appareiljusqu’àcequ’ilserapprochedelatempératureambiante
avantutilisation.
E08:l’auto-contrôledel’appareilatrouvéuneerreur.Action
recommandée:retirezetremplacezlespiles.Silecoded’erreur
serépète,retournezleCheckO
2
Plusaufabricantpourune
réparationenusine.
281176119-A
Remplacementdespiles
6Remplacementdespiles
6.1Procédurederemplacementdespiles
Lespilesdoiventêtreremplacéeslorsquel’icône
elapiles’allume.
L’icônedelapileresteraalluméejusqu’àcequelespilessoient
changées.Sileniveaudespilesesttropfaible,leCheckO
2
Plusne
s’allumerapasjusqu’àcequelespilessoientchangées.
1.Àl’aided’untourneviscruciforme1,dévissezlavisAdu
compartimentdespilesetretirezlecouvercleB.
2.Retirezlespiles.
3.Insérezdespilesneuvesetassurez-vousqu’ellessont
correctementplacées.NePAS’utiliserdepilesrechargeables.
4.Remettezlecouvercleducompartimentdespilesetserrezlavis.
5.SileCheckO
2
Plusnes’allumepaslorsquevousavezterminé,
vérifiezquelespilessoientinstalléescorrectementetqu’elles
soientneuves.
1176119-A29
7Nettoyageetentretien
7.1Nettoyage
ATTENTION!
Risqued’endommagementduproduit.
Faitesattentionpouréviterlapénétrationdetoutliquide
dansleCheckO
2
Plus.
NepastremperounePASimmergerleCheckO
2
Plusdansduliquide.
NePASmettreleappareilàl’autoclave;nesoumettez
PASnonplusl’CheckO
2
Plusàlastérilisationà
l’oxyded’éthylène.
EssuyezlessurfacesextérieuresduCheckO
2
Plusavecunchiffon
humideimbibédesavonpourlesmainsoudeliquidevaisselledoux
(pH6-8).
7.2Entretien
RemplacezlespilespardespilesAAalcalinesouaulithiumde
hautequalité.NePASutiliserdepilesrechargeables.
Lorsquel’appareiln’estpasutilisépendantplusde30jours,enlevez
lespilespourprotégerleCheckO
2
Plusd’unefuitepotentielle.
ConservezleCheckO
2
Plusentre-15°Cet60°C(5°Fet140°F).
301176119-A
Caractéristiquestechniques
8Caractéristiquestechniques
8.1ParamètresCaractéristiquesDuProduit
OXYGÈNE
Plagedemesurede
l’oxygène:partir
d’unconcentrateur):
20,9à96%
Exactitudedela
mesured’oxygène:
±1,5%duvolumetotalàtempérature
constante*
Résolutiondela
mesured’oxygène:
0,1%d’oxygène
*SeeEffetsd’undébitfaible,page27ofthisoperating
manualforinformationontheeffectsoflowflow.
FLUX
Plagedemesuredu
débit:
0à10LPM
Exactitudedela
mesuredudébit:
±0,2LPM
Précisiondela
mesuredudébit
:
0,1LPM
PRESSIONPSI
kPa
Plagedemesuredela
pression:
0,5à503,4à344
Précisiondela
mesuredelapression
:
±0,5%±0,5%
Résolutiondela
mesuredelapression
:
0,10,1jusqu’à199,1de
200à344
Tempsderéponse:
17secondes
Tempsde
préchauffage:
<1secondes
Températurede
fonctionnement:
15°Cà40°C(59°Fà104°F)
Température
d’entreposage:
-15°Cà60°C(5°Fà140°F)
Pression
barométrique:
800à1000mbar
Humidité:
0à95%(sanscondensation)
Alimentation
électrique:
2pilesalcalinesAA(2x1,5V)
Autonomiedelapile:1,100heures(16,500cyclesdelecture)
Indicateurdepile
faible:
Uneicône«PileFaible»s’afficheàl’écran
Dimensions:
3,39pox5,10pox1,00po[86,1mmx
125,5mmx25,4mm]
Poids:
0,4lb(181g)
CLASSIFICATIONS
Protectioncontreles
déchargesélectriques
:
Équipementélectriqueàsourced’énergie
interne
Protectioncontre
l’eau:
Modede
fonctionnement:
Continu
Stérilisation:Voir7.1Nettoyage,page30.
Mélanges
d’anesthésiques
inflammables:
Nepasutiliserenprésencedemélanges
d’anesthésiquesinflammables
Spécificationsde
puissance:
1,8à3,2V 32mW10mA
1176119-A31
9Garantie
9.1GarantielimitéeAmériqueduNord
Cettegarantiecouvreuniquementl’acheteur/utilisateurd’originede
nosproduits.
Cettegarantievousdonnedesdroitsspéciauxetvouspouvez
égalementjouird’autresdroitsvariantd’unétatàl’autre.
Invacaregarantitàl’acheteurd’originequeceproduitestexempt
dedéfautsaffectantlesmatériauxetlafabrication,etce,pendant
troisans(horspneusetroues).Si,durantcettepériodedegarantie,
leproduitdevaits’avérerdéfectueux,ilseraitremplacéouréparé,
àl’appréciationd’Invacare.Cettegarantitn’inclutpaslesfraisde
main-d’oeuvreoudetransportencourusdansl’installationdela
piècederechangeoularéparationduproduit.Laseuleobligation
d’Invacareetvotrerecoursexclusifsouscettegarantiesontlimités
auxréparationset/ouremplacements.
Pourleservicesousgarantie,veuillezcontacterlerevendeurquivous
avenduvotreproduitInvacare.Danslecasleservicedegarantie
nevousdonneraitpassatisfaction,veuillezécriredirectement
àInvacareàl’adresseauverso.Indiquezlenomdurevendeur,
l’adresse,lenumérodumodèle,ladated’achat,lanaturedudéfaut
et,sileproduitenporteun,lenumérodesérie.
InvacareCorporationémettrauneautorisationderetour.L’appareil
défectueuxoulespiècesdéfectueusesdoiventêtreretournéspour
uneinspectionsousgarantieaveclenumérodesérie,siapplicable,
entantqu’identifiantdanslestrente(30)jourssuivantladate
d’autorisationderetour.NEPASretournerlesproduitsànotre
usinesansnotreaccordpréalable.Lesenvoiscontreremboursement
serontrefusés.Mercideréglerlesfraisdetransport.
LIMITATIONSETEXCLUSIONS:LAGARANTIENES’APPLIQUE
PASAUXPROBLEMESPROVENANTD’UNEUSURENORMALE
OUDUNONRESPECTDESINSTRUCTIONSCI-JOINTES.EN
OUTRE,LAPRESENTEGARANTIENES’APPLIQUEPASAUX
PRODUITSPORTANTUNNUMERODESERIESILENUMERODE
SERIEAETEEFFACEOUSUPPRIME;AUXPRODUITSSOUMISA
LANEGLIGENCE,AUNACCIDENT,AUNEUTILISATION,UNE
MAINTENANCEOUUNENTREPOSAGENON-CONFORMES;
OUAUXPRODUITSAYANTSUBIDESMODIFICATIONSSANSLE
CONSENTEMENTPREALABLEECRITD’INVACARE,INCLUANT
MAISNONLIMITEESA:MODIFICATIONPARL’UTILISATION
DEPIECESOUACCESSOIRESNONAUTORISES:LESPRODUITS
ENDOMMAGESENRAISONDEREPARATIONSFAITESSUR
UNCOMPOSANTSANSLECONSENTEMENTD’INVACARE
;LESPRODUITSENDOMMAGESPARDESCIRCONSTANCES
AU-DELADUCONTROLED’INVACARE;LESPRODUITS
REPARESPARTOUTAUTREQU’UNREVENDEURINVACARE,
L’EVALUATIONESTLAISSEEAL’APPRECIATIOND’INVACARE.
LAPRESENTEGARANTIEEXPRESSEESTEXCLUSIVEET
REMPLACETOUTEAUTREGARANTIE,EXPRESSEOU
IMPLIQUEE,YCOMPRISLESGARANTIESIMPLIQUEES
DEQUALITEMARCHANDEETCONFORMITEAUNE
UTILISATIONPARTICULIERE,ETLESEULRECOURSENCAS
DEVIOLATIONSDETOUTEGARANTIEQUISOITESTLIMITEE
AUXREPARATIONSOUREMPLACEMENTSDUPRODUIT
DEFECTUEUXPROCEDANTDESPRESENTESCONDITIONS.
L’APPLICATIONDETOUTEGARANTIEIMPLIQUEENE
S’ETENDPASAU-DELADELADUREEDELAGARANTIE
EXPRESSEFOURNIEICI.INVACARENESAURAITÊTRETENU
RESPONSABLEDEQUELQUEDOMMAGECONSÉQUENTOU
FORTUIT.
CETTEGARANTIESERAETENDUEPOURSECONFORMERAUX
EXIGENCESLEGALESDEL’ETAT/DELAPROVINCE.
321176119-A
Garantie
9.2Garantie
Invacare®garantitl'absencededéfautsetlebonfonctionnementde
votreproduit.Lagaranties'étendàtouslesdéfautsetanomalies
quisontdémontrésêtredusàuneconstructiondéfectueuse,àun
mauvaismatériauouàuneconceptionerronée.Seulledistributeur
agrééetnonl’utilisateurduproduit,peutfairevaloirdesdroitsde
garantievis-à-visdeInvacare®.
Nefontpaspartiedelagarantiel'usurenormale,lessuitesd'un
maniementnonconformeoud'unedétérioration,unmauvais
entretien,unmontageouunemiseenserviceincorrect(e)dufaitde
l'acheteuroudetiers,ainsiquelesdéfautsdusàdescirconstances
extérieures.L'obligationdegarantieexpiresidesmodifications
nonprévuesounonréaliséesparlerevendeurspécialisésont
apportéesauproduitouencasd'utilisationdepiècesderechange
nonconformes.LagarantiedeInvacare®necomprendpaslesfrais
consécutifsàl'éliminationdesdéfauts,telsquelesfraisdetransport
etdedéplacement,lescoûtssalariaux,lescharges,etc.
Ledélaidegarantieestde24mois.Lespiècesd'usuresontexclues
delagarantie.
Parailleurs,lestermesdelagarantiesontpropresauxconditionsde
ventesdechaquepaysdanslequelleproduitestvendu.
1176119-A33
Notes
Contenido
Estemanualdebeserentregadoalusuariofinal.deusaresteproducto
leaestemanualyguárdeloparafuturasreferencias.
1Generalidades.................................36
1.1Símbolos.................................36
1.2Usoprevisto..............................36
2Resumensobreelsistema.......................37
2.1Descripciónyprincipiodefuncionamiento........37
2.2Identificacióndecomponente.................37
2.3Guíadesímbolos..........................38
2.4Descripcióndecomponente..................38
2.5Seincluyeconsuunidad.....................38
3Seguridad....................................39
3.1InstruccionesGenerales......................39
3.2Eliminación...............................41
4Instrucionesdeoperación.......................42
4.1Medicióndeflujoypresióndeoxígeno...........42
4.2Cómocambiarunidadesdemedicióndepresión
.......................................42
4.3Procedimientodeverificacióndecalibración.......42
4.4Factoresqueinfluyenenunalecturaprecisa........42
Efectosdelatemperatura....................42
Efectosdelahumedad.......................43
Efectosdeotrosgases.......................43
Efectosdebajoflujo.........................43
5Códigosdeerror...............................44
5.1CódigosdeError..........................44
6Cómocambiarlasbaterías......................45
6.1Procedimientodesustitucióndebaterías.........45
7Limpiezaymantenimiento......................46
7.1Limpieza.................................46
7.2Mantenimiento............................46
8Datostécnicos.................................47
8.1ParámetrosHabitualesdelProducto.............47
9Garantía.....................................48
9.1Garantíalimitada-Norteamérica...............48
9.2Garantía.................................49
1Generalidades
1.1Símbolos
Enestemanualseutilizansímbolosquehacenreferenciaapeligros
ousospocosegurosquepuedenprovocarlesionesodañosala
propiedad.Acontinuaciónsemuestranlasdescripcionesdeestos
símbolos.
¡PELIGRO!
Peligroindicaunasituacióninminenteypeligrosaque,
sinoseevita,provocarálamuerteolesionesserias.
¡ADVERTENCIA!
Indicaunasituaciónpotencialmentepeligrosaquesino
seevitapuedetenercomoconsecuencialamuerteo
lesionesgraves.
¡PRECAUCIÓN!
Precauciónindicaunasituaciónderiesgopotencial
que,sinoseevita,puedeprovocardañosenla
propiedadolesioneslevesoambas.
Proporcionaconsejosútiles,recomendacioneseinformación
paraunusoeficienteysinproblemas.
EsteproductocumpleconlaDirectiva93/42/EECenlo
concernienteadispositivosmédicos.
Lafechadelanzamientodeesteproductofiguraenla
declaracióndeconformidadCE.
1.2Usoprevisto
¡ADVERTENCIA!
ElCheckO
2
Plusestádestinadosolamenteparala
comprobacióndeconcentradoresdeoxígeno.
NOuseelCheckO
2
Plusparaelmonitoreocontinuo
deoxígeno.
ElCheckO
2
Plussolodebeserutilizadoporpersonalcapacitado.
ElanalizadordeoxígenoCheckO
2
Plusmidelaconcentraciónyel
flujodeoxígenomedianteunatecnologíadeultrasonidoymidela
presiónmedianteunsensordepresión.
ElanalizadordeoxígenoCheckO
2
Plusesunaherramientaquese
utilizaparamedirlapureza,elflujoylapresióndeunconcentrador
deoxígeno.ElCheckO
2
Plusnoestádestinadoaserutilizadopor
pacientesaquienesselesprescribaoxígeno,niestádestinadopara
monitorearoconfirmardeformacontinualaentregadeoxígeno
aunpaciente.
Elanalizadordeoxígenoestadestinadoparautilizarseenentornos
endondeseestédandomantenimientooreparandoconcentradores
deoxígeno.Estoincluyehospitales,residenciasparaancianos,
instalacionesdeatenciónextendida,residenciasparapacientesy
centrosdereparaciónymantenimientodedispositivosderespiración.
361176119-A
Resumensobreelsistema
2Resumensobreelsistema
2.1Descripciónyprincipiodefuncionamiento
ElCheckO
2
Plusesunanalizadordeoxígenodiseñadopara
comprobarlaconcentracióndeoxígeno,elflujoylapresiónde
salidadeconcentradoresdeoxígeno.ElCheckO
2
Plusofreceun
rendimientosinparalelosgraciasasuavanzadodiseño,eincluyelas
siguientesventajasfuncionalesyoperacionales:
Medicionesprecisasdeoxígeno
Noserequieredecalibraciónencampo.
CapacidadparamedirpresiónenPSIokPa,locualresultamuy
práctico.
Diseñocompactoyduradero
Pantalladecristallíquido(LCD)grandeyfácildeleer
Puertodeentradadegasblindadoyreforzado
BateríasAAconlargavidaútil
Apagadoautomáticodespuésde4minutos.
Indicacióndebateríabaja
Autodiagnóstico
Fácildelimpiar
2.2Identificacióndecomponente
A
Lapantalla
LCD
D
Entradade
muestradegas
B
Botónde
modo
E
Salidademuestra
degas
C
Botón
ON/OFF
F
Compartimento
debaterías
1176119-A37
2.3Guíadesímbolos
ElCheckO
2
Plusposeelossiguientessímbolosyletrerosde
seguridad:
Representante
autorizadoenla
ComunidadEuropa
Botónon/off
Notirar.Para
desecharlaunidad
sigalasdirectrices
locales.
Botóndemover
EvaluadoporETL
(Laboratoriosde
comprobación
Intertek)
Bateríabaja
Fabricante Litrosporminuto
Proteccióncontra
ingreso
Librasporpulgada
cuadrada
Nocontienelátex Kilopascales
Númerodeserie Porciento
Númerodecatálogo Entradade
muestradegas
Consultela
documentación
adjunta
Salidademuestra
degas
Corriente
continua
2.4Descripcióndecomponente
Pantalladigital31/2-LapantallaLCDofrecelecturasdirectasde
concentracióndeoxígeno,flujodegasypresióndegas.Lapantalla
LCDtambiénmuestraloscódigosdeerrorsegúncorresponda.
BotónON/OFF-Apagayenciendeelequipo.
Botóndemodo-Cambiaentrelamedicióndeconcentraciónde
gasproducidoporunconcentradordeoxígenoylamediciónde
oxígenopuro(paralaverificacióndecalibración).
IndicadordebateríabajaIndicaquelatensiónenvolteosdelas
bateríasestápordebajodelosnivelesnormalesdefuncionamiento.
LPMSeiluminaalladodelaindicacióndemedicióndeflujo.(nose
muestracuandoenelmododeverificacióndecalibración).
KPAIndicaquelamedicióndelapresiónsedaenunidadesde
kilopascales.
PSIIndicaquelamedicióndelapresiónsedaenunidadesdelibras
porpulgadacuadrada.
Símbolo"%"Seiluminaalladodelaindicacióndemediciónde
concentración.
EntradademuestradegasSeutilizapararecibirlamuestra
degas.
SalidademuestradegasSeutilizacomosalidadelamuestra
degasycuandosecierraactúacomodisparadordelamediciónde
presión.
TubodemuestradegasSeutilizaparaconectarelequipoalas
fuentesdemuestradegas.
2.5Seincluyeconsuunidad
Manualdelusuario
Tuberíaparamuestradegas
Tapasuave
381176119-A
Seguridad
3Seguridad
3.1InstruccionesGenerales
¡ADVERTENCIA!
Estaseccióncontieneinformaciónimportanteparael
funcionamientoyusosegurodeesteproducto
NOUTILICEESTEPRODUCTONICUALQUIER
OTROEQUIPOOPCIONALDISPONIBLESIN
ANTESHABERLEÍDOYCOMPRENDIDOESTAS
INSTRUCCIONESYCUALQUIEROTROMATERIAL
INFORMATIVOADICIONAL,COMOMANUALES
DELUSUARIO,MANUALESDESERVICIOU
HOJASDEINSTRUCCIONESPROPORCIONADOS
CONESTEPRODUCTOOEQUIPOOPCIONAL.
SITIENEALGUNADUDARELACIONADA
CONLASADVERTENCIAS,PRECAUCIONESO
INSTRUCCIONES,PÓNGASEENCONTACTO
CONUNPROFESIONALSANITARIO,SU
REPRESENTANTEOUNTÉCNICOANTESDE
INTENTARUTILIZARESTEEQUIPO.DELO
CONTRARIO,EXISTEELRIESGODEPRODUCIRSE
LESIONESODAÑOS.
ADVERTENCIADELOSACCESORIOS
LosproductosInvacareestánespecíficamente
diseñadosyfabricadosparausarseconjuntamente
conlosaccesoriosInvacare.Invacarenohaprobado
losaccesoriosdiseñadosporotrosfabricantesy,por
consiguiente,noestánrecomendadosparausarsecon
losproductosInvacare.
¡PELIGRO!
PARAREDUCIRELRIESGODE
QUEMADURAS,ELECTROCUCIÓN,
INCENDIOOLESIONESAPERSONAS
Nodebeutilizarseenaplicacionesconanestesiaopara
medirconcentracionesdeoxígenoprovenientesde
fuentesquenoseanlosconcentradoresdeoxígeno
convencionales.
Nodebeutilizarseagentesdeinhalación.Hacer
funcionarelCheckO
2
Plusenentornosexplosivoso
inflamablespuedeprovocarincendiosoexplosiones.
Noadecuadoparautilizarseenpresenciademezclas
anestésicasinflamables.
Eloxígenoacelerarápidamentelacombustión.No
fumecuandoestéutilizandoelCheckO
2
Pluspara
comprobarconcentradoresdeoxígeno.
Nosedebeusarenentornosderesonanciamagnética.
1176119-A39
¡ADVERTENCIA!
ElusoinadecuadodelCheckO
2
Pluspuedeprovocar
lecturasdeoxígenoimprecisas,locualpuedeconllevar
alaindicacióndetratamientosinadecuadosy/ocausar
dañosalpaciente.Sigalosprocedimientosquese
describenenestemanual.
Losusuariosdebenconocerbienlainformaciónque
contieneestemanualdeoperacionesantesdeluso
delequipo.Paraelfuncionamientoseguroyefectivo
delproductoesnecesarialaobservanciaestrictade
lasinstrucciones.Esteproductofuncionarásolopara
loquehasidodiseñadosiseoperacumpliendocon
lasinstruccionesdeoperaciónproporcionadaspor
elfabricante.
NOuseelCheckO
2
Plusparamedirlaconcentración
deoxígenodeconcentradorescuandolavelocidad
deflujoseainferioraladesurendimientoóptimo,
especificadoporelfabricante,dichavelocidades
generalmente4LPMomenosenconcentradorescon
unflujomáximode10LPM,yde1LPMomenosen
concentradoresconunflujomáximode5LPM.
UtilizarelCheckO
2
Pluscercadeobjetosquegeneran
camposeléctricospuedeprovocarlecturaserróneas.
¡ADVERTENCIA!
SielCheckO
2
Plusseexpusieraalíquidosderramados
osesumergieraenellos,quiteinmediatamentelas
bateríasydejequeelequiposesequecompletamente.
Cuandoestéseco,sustituyalasbateríasycompruebe
quefuncionacorrectamente.
NoesteriliceelCheckO
2
Plusenautoclavesnilo
expongaaaltastemperaturas(>60°C[140°F]).
NOloesteriliceconóxidodeetileno.
NOexpongaelCheckO
2
Plusairradiaciones,vacío,
vaporocompuestosquímicosfuertes.
NOexpongaelCheckO
2
Plusapresionessuperiores
alos50psi.Laexposiciónapresionesporencimade
los50psipuedecausarfiltracioneseneldispositivo
quepudieranafectarsudesempeñoenlaslecturasde
flujoypresión.
LareparaciónomodificacióndelCheckO
2
Pluspor
cualquierindividuoquenoseaelagenteautorizado
deInvacarepuedeconllevaraqueelproductono
funcionecomoseespera.
401176119-A
Seguridad
¡PRECAUCIÓN!
SustituyalasbateríasporbateríasAAdelitiooalcalinas
dealtacalidad.NOusebateríasrecargables.
Cuandonolovayaautilizarpormásde30días,quite
lasbateríasparaprotegerelCheckO
2
Pluscontra
posiblesderramesdelasbaterías.
EvitedejarcaerelCheckO
2
Plusparaprotegerlo
contradañosquepuedenafectarsurendimiento.Si
sesospechaqueelequipopresentadaños,realice
elprocedimientodecalibracióndeverificaciónque
sedescribeen4.3Procedimientodeverificaciónde
calibración,página42
.
Evitequemateriasextrañaspenetrenalinteriordel
CheckO
2
Plus.
NOutiliceelCheckO
2
Plusparacomprobarun
concentradorquetengainstaladounhumidificador.La
humedaddelhumidificadorpuededañarelequipo.
NOcompruebeunconcentradoraltiempoque
mantienepresionadoelbotóndemodo,delo
contrariolalecturanoseráprecisa.
Despuésdehaberloguardadoencondicionesdefrío
ocalorextremos,dejequeelgasfluyaatravésdel
analizadorporuntiemposuficientecomoparaquelos
sensoresinternosalcancenlatemperaturadelflujo
degasoespereaqueelanalizadorseequilibrea
temperaturaambienteantesdeutilizarlo.
3.2Eliminación
Esteproductohasidosuministradoporunfabricanteconscientepor
elmedioambientequecumpleconlaNormativadeDesechosde
EquiposEléctricosyElectrónicos(WEEE)2002/96/CE.
Esteproductopuedecontenersustanciasquepuedenserperjudiciales
paraelmedioambientesisedesechaenlugares(vertederos)queno
seanlosapropiadossegúnlalegislación.
Protejaelmedioambienteyrecicleesteproductoatravésdela
plantadereciclajemáspróximacuandolleguealfinaldesuvidaútil.
Lasbateríasylaplacadecircuitonodebendesecharseconlabasura
corriente.
1176119-A
41
4Instrucionesdeoperación
4.1Medicióndeflujoypresióndeoxígeno
Paracomprobarlaconcentracióndeoxígenoylapresiónyelflujode
unamuestradegasprovenientedeunconcentrador:
1.Conectelatuberíaparalamuestradegasalaentradademuestra
degasdelCheckO
2
Plus.
2.Fijeelotroextremodelatuberíaparamuestradegasal
concentradordeoxígeno.
3.InicieelflujodegashaciaelCheckO
2
Plusaunavelocidadde1
litroa10litrosporminuto(serecomienda2litrosporminuto).
Asegúresedequelasalidadelconcentradoseaestable,segúnlas
recomendacionesdelfabricante.
4.EnciendaelCheckO
2
Plus.
5.Dejequelalecturadeoxígenoseestabilicedurante
aproximadamente10segundosantesdecompletarlalecturade
concentraciónyflujodeoxígeno.
6.Paracomprobarlapresión,tapelasalidademuestradegascon
eldedomientraselgasestéfluyendo.
7.Espere5segundosaquelapantallamuestrelalecturadepresión.
NOmantengapresionadoelbotóndemodomientras
verificaunconcentrador,delocontrariolalecturano
seráprecisa.
4.2Cómocambiarunidadesdemediciónde
presión
ElCheckO
2
PluspuedemedirpresiónenPSIokPa.ElCheckO
2
Plus
estáconfiguradodefábricaparamedirenPSI.ParacambiaraKPa:
1.ConundestornilladorPhillipsaflojelacompuertadel
compartimentodelasbateríasyquítela.
2.Cambieelconmutadorqueseencuentradentrodel
compartimentodelasbaterías.
3.Vuelvaaponerlacompuertadelcompartimentodebateríasy
aprieteeltornillo.
4.3Procedimientodeverificacióndecalibración
ParacomprobarqueelCheckO
2
Plusestáfuncionandobien,se
incluyeelmododeverificación.Pararealizarlaverificaciónde
calibración:
1.EnciendaelCheckO
2
Plus.
2.Conecteunafuentedeoxígenopuro(99.95%)alaentradade
muestradegas.
3.Hagafluirde2LPMa5LPMdegasporelinteriordelCheckO
2
Plus.AsegúresedequeelgasestéfluyendoporelCheckO
2
Plusaunatemperaturaestable.
4.Pulseymantengalapulsadoelbotóndemodo.Mientras
mantienepulsadoelbotóndemodo,lamedicióndegasdebedar
unalecturade98.5%y101.5%deoxígeno.Silamedicióndegas
noestádentrodeesterango,llamealdepartamentodeservicio
alcliente.Calibraciónelmododeverificaciónseindicaporlos
letreros"CAL"y"VER"queparpadeanenlapantalladebajodela
indicacióndemedicióndegas.
4.4Factoresqueinfluyenenunalecturaprecisa
Efectosdelatemperatura
ElCheckO
2
Plusrealizaunacompensacióndetemperaturay
funcionarásegúnlasespecificacionesentodoelrangodetemperatura
defuncionamiento.Sinembargo,sedebeevitartomarmediciones
duranteperíodosdecambiosbruscosdetemperatura.
42
1176119-A
Instrucionesdeoperación
Efectosdelahumedad
ElCheckO
2
Plusposeeunsensordehumedadparadetectary
compensarlahumedaddelgasqueentraenelequipo.Noobstante,
losaltosnivelesdehumedad(concondensado)puedenafectarla
precisiónyfiabilidaddelCheckO
2
Plus.Paraevitarposiblesdaños:
Eviteutilizarelequipoenentornosdondelahumedadrelativa
supereel95%.
NOuseesteequipointegradoauncircuitoderespiración.
NOrespirenisoplehaciaelinteriordelCheckO
2
Plus.
Efectosdeotrosgases
ElCheckO
2
Plusestádiseñadoparamedirdostiposdiferentesde
mezclasdegas:
Oxígeno,nitrógenoyargónprovenientesdeunconcentrador.
Oxígenopuroenelmododeverificacióndecalibración
Cualquierotraconcentraciónocombinacióndegasesharáqueel
CheckO
2
Plusrealicemedicionesincorrectasdeconcentraciónde
oxígeno.
Efectosdebajoflujo
Losconcentradoresdeoxígenofuncionansegúnelprincipiode
extraccióndelnitrógenodelaire,dejandoeloxígenoyelargón
concentradosaunaproporciónespecíficadeoxígeno/argón.
Esteprincipiodefuncionamientopuedealterarsecuandolos
concentradoresestánconfiguradosparafluirenelextremobajode
surangodefuncionamiento.Enflujosbajos,estopuedengenerar
bajaconcentracióndeoxígenoenlasalida,porejemplo,de85%
a91%,pormotivosquenosonelaltocontenidodenitrógeno,
posiblementeporunincrementoenelcontenidodeargón.ElCheck
O
2
Plusrequierequelaproporcióndeoxígenoyargónpermanezca
constanteparapodergarantizarunaprecisiónde+/-1.5%deoxígeno.
NOuseelCheckO
2
Plusparamedirconcentracionesdeoxígeno
deunconcentradorcuandofluyeavelocidadesmásbajasquela
requeridaparasufuncionamientoóptimo,segúnloespecificael
fabricantedelconcentrador;generalmente4LPMomenosen
concentradoresconunflujomáximode10LPM,y1LPMomenos
enconcentradoresqueposeenunflujomáximode5LPM.
1176119-A43
5Códigosdeerror
5.1CódigosdeError
ElCheckO
2
Plusposeefuncionesdeauto-diagnósticoincorporadas
alsoftwareparadetectarlecturasincorrectasfueradelosrangos
defuncionamientonormal.Loscódigos,descripcionesyacciones
recomendadasson:
E01:Medicióndeoxígenofueraderango,Alto(102.0%
calculadoporalgoritmo).
Acciónqueserecomienda:VerificarqueelCheckO
2
Plusesté
siendoutilizadoenelmodocorrecto(mododeverificaciónde
concentradoroverificacióndecalibración).Sielcódigodeerror
serepite;realiceunaverificacióndecalibraciónsegúnlodescrito
enlasección4.3deestemanual.Sielcódigodeerrorserepitede
nuevo;contacteconeldepartamentodeservicioalcliente.
E02:Medicióndeoxígenofueraderango,Bajo(-2.0%
calculadoporalgoritmo).
Acciónqueserecomienda:VerificarqueelCheckO
2
Plusesté
siendoutilizadoenelmodocorrecto(mododeverificaciónde
concentradoroverificacióndecalibración).Sielcódigodeerror
serepite;realiceunaverificacióndecalibraciónsegúnlodescrito
enlasección4.3deestemanual.Sielcódigodeerrorserepitede
nuevo;contacteconeldepartamentodeservicioalcliente.
E03:Faltalamemoriadeldispositivooestáenmalestado.
Acciónqueserecomienda:Contacteconeldepartamentode
servicioalcliente.
E04:Laseñaldelecturanoesestable.
Acciónqueserecomienda:Contacteconeldepartamentode
servicioalcliente.
E05:Medicióndepresiónfueraderango,Alto(50PSI).
Acciónqueserecomienda:Compruebelapresiónconuna
fuentedegasconocida.Sisielcódigodeerrorserepite,contacte
coneldepartamentodeservicioalcliente.
E06:Fueradelatemperaturadefuncionamiento,Alta
(40°C).
Acciónqueserecomienda:ElCheckO
2
Plusestádemasiado
caliente,refresqueelequipollevándoloaunatemperaturacercana
alatemperaturaambienteantesdeutilizarlo.
E07:Fueradelatemperaturadefuncionamiento,Baja
(15°C).
Acciónqueserecomienda:ElCheckO
2
Plusestádemasiado
frío,calienteelequipollevándoloaunatemperaturacercanaala
temperaturaambienteantesdeutilizarlo.
E08:Errordeauto-comprobacióndelequipo.
Acciónqueserecomienda:Quiteysustituyalasbaterías.Si
elcódigodeerrorserepite;Contacteconeldepartamentode
servicioalcliente.
44
1176119-A
Cómocambiarlasbaterías
6Cómocambiarlasbaterías
6.1Procedimientodesustitucióndebaterías
Lasbateriasdebencambiarsecuandoel
íconoseilumina.Elícono
semantendráiluminadohastaquelasbateríastengancarga.Sielnivel
delasbateríasesdemasiadobajo,elCheckO
2
Plusnoseencenderá
hastaquesehayancambiadolasbaterías.
1.Conundestornillador#1Phillips(estrella)aflojeaflojeeltornillo
AdelapuertadelcompartimentodelasbateríasByquítela.
2.Quitelasbaterías.
3.Insertelasbateríasasegurándosederespetarlacorrecta
polaridad.NOusebateríasrecargables.
4.Vuelvaaponerlacompuertadelcompartimentodebateríasy
aprieteeltornillo.
5.SielCheckO
2
Plusnoseenciendecuandoterminede
cambiarlas,compruebeque
lasbateríasesténinstaladascorrectamenteyqueseannuevas.
1176119-A45
7Limpiezaymantenimiento
7.1Limpieza
¡PRECAUCIÓN!
Riesgodedañosenelproducto.
Seaprecavidoenelusodelequipoparaevitarque
cualquierfluidopenetreenelCheckO
2
Plus
NOsumerjaelCheckO
2
Plusenningúnfluido.
NoesteriliceelCheckO
2
Plusconautoclaves,nicon
óxidodeetileno.
LimpielassuperficiesexterioresdelCheckO
2
Plusconjabónde
manosodetergenteparaplatossuave(pH6-8).
7.2Mantenimiento
SustituyalasbateríasporbateríasAAdelitiooalcalinasdealta
calidad.NOusebateríasrecargables.
Cuandonolovayaautilizarpormásde30días,quitelasbaterías
paraprotegerelCheckO
2
Pluscontraposiblesderramesdelas
baterías.
GuardeelCheckO
2
Plusentre-15˚Cy60˚C
461176119-A
Datostécnicos
8Datostécnicos
8.1ParámetrosHabitualesdelProducto
OXÍGENO
Rangodemedición
deoxígeno:
(provenientedeun
concentrador)
20,9-96%
Precisiónde
medicióndeoxígeno:
±1,5%afondodeescalaatemperatura
constanteyflujoóptimo*
Resoluciónde
medicióndeoxígeno:
0,1%deoxígeno
*VerEfectosdebajoflujo,página43deestemanual
deoperaciónparaobtenerinformaciónsobrelas
consecuenciasdelflujobajo.
FLUJO
Rangodemedición
deflujo:
de0LPMa10LPM
Precisiónde
medicióndeflujo:
±0,2LPM
Resoluciónde
medicióndeflujo:
0,1LPM
PRESIÓN
PSI
KPA
Rangodemedición
depresión:
0,5-503,4-344
Precisiónde
medicióndepresión:
±0,5%±0,5%
Resoluciónde
medicióndepresión:
0,10,1a199,1desde
200a344
Tiempoderespuesta:
17segundos
Tiempode
calentamiento:
<1segundo
Temperaturade
funcionamiento:
15°C-40°C(59°F-104°F)
Temperaturade
almacenamiento:
-15°C-60°C(5°F-140°F)
Presión:
800-1000mBares
Humedad:
de0a95%(sincondensado)
Requerimientosde
alimentaciónelétrica:
2bateríasAAalcalinas(2x1.5Volteos)
Vidaútildelabatería:
1,100horas(16500ciclosdelectura)
Indicacióndebatería
baja:
Iconodebateríabajamostradoenla
pantallaLCD
Dimensiones:
3.39"x5.10"x1.08"[86.1mmx125.5
mmx25.4mm]
Peso:
0.4libras(181g)
CLASIFICACIONES
Proteccióncontra
choqueelétrico:
Equipoconalimentacióneléctricainterna
Proteccióncontrael
agua:
Modode
funcionamiento:
Continuo
Esterilización:
Ver7.1Limpieza,página46.
Mezclaanestésica
inflamable:
Noadecuadoparautilizarseenpresencia
demezclasanestésicasinflamables
Especificacionesde
alimentaciónelétrica:
1,8-3,2V 32mW10mA
1176119-A47
9Garantía
9.1Garantíalimitada-Norteamérica
TENGAENCUENTAQUELASIGUIENTEGARANTÍA
SEHAREDACTADOPARACUMPLIRCONLAS
LEYESFEDERALESAPLICABLESALOSPRODUCTOS
FABRICADOSAPARTIRDEL4DEJULIODE1975.
Estagarantíaseextiendeúnicamentealcomprador/usuariooriginal
denuestrosproductos.
Estagarantíaleconcedederechoslegalesespecíficos,aunquepuede
disponerdeotrosderechoslegalesquepuedendiferirentredistintos
estados.
Conestagarantía,Invacaregarantizaquesusproductosestaránlibres
dedefectosdematerialesymanodeobradurantetresañosapartir
delafechadecompraoriginal(exceptuandoruedasyneumáticos).Si
duranteesteperíododelagarantíasedemuestraquelosproductos
sondefectuosos,seprocederáalareparaciónosustitucióndelos
mismos,segúnloqueInvacareestimeoportuno.Estagarantíano
incluyelosgastosdemanodeobraoenvíoderivadosdelareparación
olainstalacióndelaspiezasderecambiodelosproductos.Laúnica
obligacióndeInvacareylasoluciónexclusivaparaelusuariobajoesta
garantíaestálimitadaadichareparacióny/osustitución.
Paraobtenerinformaciónsobreelserviciodelagarantía,póngaseen
contactoconeldistribuidoraquiencompróelproductoInvacare.En
elsupuestodenorecibirunserviciodegarantíasatisfactorio,escriba
directamenteaInvacareenviandounacartaaladirecciónpostal
indicadaenlaúltimapágina.Especifiqueelnombredeldistribuidor,la
dirección,elnúmerodemodelo,lafechadecompra,lanaturalezadel
defectoy,sielproductoestáserializado,elnúmerodeserie.
InvacareCorporationemitiráunaautorizacióndedevolución.La
unidadolapiezadefectuosadeberáserdevueltaparasometerseala
inspeccióndegarantíaenelespaciodetreinta(30)díasapartirdela
fechadeautorizacióndedevolución,indicandocomoidentificaciónel
númerodeserie,siprocede.NOdevuelvaningúnproductoafábrica
sinnuestroconsentimientoprevio.Losenvíoscontrareembolsono
estánadmitidos.Porfavor,paguelosgastosdeenvíoconantelación.
LIMITACIONESYEXCLUSIONES:LAGARANTÍANOES
APLICABLEPARALOSPROBLEMASSURGIDOSPOREL
DESGASTENORMALNIPARALOSPROBLEMASOCASIONADOS
PORNOSEGUIRLASINSTRUCCIONESADJUNTAS.ADEMÁS,
LAGARANTÍAANTESMENCIONADANOSEAPLICARÁ
ALOSPRODUCTOSCONNUMERACIÓNDESERIESIEL
NÚMERODESERIESEHAELIMINADOOBORRADO;LOS
PRODUCTOSQUEPUEDANHABERESTADOSOMETIDOS
AUNUSONEGLIGENTE,ACCIDENTE,UTILIZACIÓN
INADECUADA,MANTENIMIENTOOALMACENAMIENTO;O
LOSPRODUCTOSMODIFICADOSSINELCONSENTIMIENTO
EXPRESOPORESCRITODEINVACARE,INCLUIDOS,PEROSIN
LIMITARSEA:LAMODIFICACIÓNPORMEDIODELUSODE
PIEZASOACCESORIOSNOAUTORIZADOS;PRODUCTOS
DAÑADOSCOMOCONSECUENCIADEREPARACIONES
REALIZADASENCOMPONENTESSINELCONSENTIMIENTO
ESPECÍFICODEINVACARE;PRODUCTOSDAÑADOSPOR
CIRCUNSTANCIASAJENASALCONTROLDEINVACARE;
PRODUCTOSREPARADOSPORALGUIENQUENOSEA
DISTRIBUIDORDEINVACARE,TALEVALUACIÓNSOLAMENTE
LAPODRÁDETERMINARINVACARE.
LAPRESENTEGARANTÍAEXPRESAESEXCLUSIVAEINVALIDA
CUALQUIEROTRAGARANTÍA,EXPRESAOIMPLÍCITA,
INCLUIDASLASGARANTÍASIMPLÍCITASDECARÁCTER
COMERCIALYSUJETASAUNUSOPARTICULAR;ELÚNICO
RECURSOENCASODEINCUMPLIMIENTODECUALQUIER
TIPODEGARANTÍASELIMITAALAREPARACIÓNO
SUSTITUCIÓNDELPRODUCTODEFECTUOSOTALY
481176119-A
Garantía
COMOSEESPECIFICAENLASPRESENTESCONDICIONES.
LAAPLICACIÓNDETODAGARANTÍAIMPLICADANO
PUEDEAMPLIARMÁSALLÁDELADURACIÓNEXPRESADE
GARANTÍAINDICADAANTERIORMENTE.INVACARENOSERÁ
RESPONSABLEDENINGÚNDAÑOINCIDENTALODERIVADO.
ESTAGARANTÍAPUEDEAMPLIARSEPARACUMPLIRCONLAS
LEYESYREQUISITOSDECADAESTADOOPROVINCIA.
9.2Garantía
Invacare®garantizaelperfectoestadoyfuncionamientodesu
producto.Lagarantíacubretodaslasaveríasydefectosquedeforma
probadaprocedendeunafabricaciónincorrecta,malacalidaddelos
materialesomodelodefectuoso.Losderechosdegarantíafrentea
Invacare®sólopuedenserreclamadosporeldistribuidor,ynopor
elusuariodelproducto.
Estagarantíanocubrelasconsecuenciasdeldesgastenormal,de
unusoincorrectoodaños,asícomolafaltademantenimiento,el
montajeopuestaenmarchadefectuososporpartedelcomprador
odeterceros,oproblemasquesonconsecuenciadecircunstancias
externas.Laobligacióndegarantíasecancelacuandoenelproducto
sehanrealizadomodificacionesnoprevistasynoejecutadasporel
distribuidorespecializado,asícomoporelempleoderecambios
inapropiados.Lagarantíanoincluyelosgastosquesurgencomo
consecuenciadelasubsanacióndelproblema,porejemplolosfletes
otransporte,costessalariales,gastosdeviaje,etc.
Elplazodevalidezdelagarantíaesde24meses.Laspiezasdecierre
quedanexcluidasdelagarantía.
Además,lostérminosycondicionessonpartedelostérminosy
condicionesgeneralesespecíficosparacadapaísenelquesevende
esteproducto.
1176119-A49
Notes
Inhaltsverzeichnis
DieseGebrauchsanweisungmussdemBenutzerdesProdukts
ausgehändigtwerden.LesenSiedieseGebrauchsanweisungvor
VerwendungdesProduktesundbewahrenSiesiefürdenweiteren
Gebrauchauf.
1Allgemeines...................................52
1.1Symbole.................................52
1.2Anwendungszweck..........................52
2Systemübersicht...............................53
2.1Beschreibung&Arbeitsweise..................53
2.2BeschreibungderBestandteile.................53
2.3Symbolübersicht...........................54
2.4ErklärungderBestandteile....................54
2.5LieferumfangdesGeräts.....................54
3Sicherheit....................................55
3.1AllgemeineRichtlinien.......................55
3.2Entsorgung...............................57
4Bedienungsanweisungen........................58
4.1MessungvonSauerstoff,DurchflussundDruck
.......................................58
4.2WechselderDruckmaßeinheit.................58
4.3ÜberprüfungderKalibrierung.................58
4.4Faktoren,diegenaueMessungen
beeinträchtigen............................58
AuswirkungenderTemperatur................58
AuswirkungenderLuftfeuchtigkeit..............58
AuswirkungenandererGase..................59
AuswirkungenderLuftflusses..................59
5Fehlercodes...................................60
5.1Fehlercodes...............................60
6AustauschderBatterien........................61
6.1AustauschderBatterien.....................61
7ReinigungundWartung.........................62
7.1Reinigung.................................62
7.2Wartung................................62
8TechnischeDaten..............................63
8.1TypischeProduktparameter...................63
9Garantie.....................................64
9.1Garantie.................................64
1Allgemeines
1.1Symbole
IndiesemHandbuchwerdenSignalwörterverwendet,umauf
GefahrenoderunsicherePraktikenhinzuweisen,diezuVerletzungen
oderSachschädenführenkönnen.DieDefinitionenderverwendeten
SignalwörterfindenSieindernachfolgendenTabelle.
GEFAHR!
DasWortGefahrbezeichneteineunmittelbar
gefährlicheSituation,die,wennsienichtvermieden
wird,zuschwerenodertödlichenVerletzungenführt.
WARNUNG!
DasSignalwort„Warnung“weistaufeinepotenziell
gefährlicheSituationhin,diebeiNichtbeachtungzum
TododerzuschwerenVerletzungenführenkönnte.
VORSICHT!
BezeichneteinepotenziellgefährlicheSituation,die,
wennsienichtvermiedenwird,zuSachschädenoder
geringfügigenVerletzungenoderbeidemführenkann.
NützlicheTipps,EmpfehlungenundInformationenfüreine
effizienteundproblemloseVerwendung.
DiesesProduktentsprichtderRichtlinie93/42/EWGüber
Medizinprodukte
DerMarkteinführungszeitpunktfürdiesesProduktistinder
CE-Konformitätserklärungangegeben.
1.2Anwendungszweck
WARNUNG!
DerCheckO
2
Plusdientausschließlichder
ÜberprüfungvonSauerstoffkonzentratoren.
VerwendenSiedenCheckO
2
PlusNICHTfürdie
kontinuierlicheSauerstoffüberwachung.
DerCheckO
2
PlusdarfnurvondafürgeschultemPersonal
verwendetwerden.
DerCheckO
2
PlusSauerstoffsensormisstmithilfevon
UltraschalltechnologieSauerstoffkonzentrationundDurchflussund
misstmithilfeeinespiezoresistivenSilikondrucksensorsdenDruck.
DerCheckO
2
PlusSauerstoffsensoristeinGerätfürdie
MessungvonSauerstoffreinheit,DurchflussundDruckeines
Sauerstoffkonzentrators.DerCheckO
2
PlusistnichtfürPatienten
vorgesehen,denenSauerstoffverschriebenwurdeundesdarf
nichtfürdiekontinuierlicheÜberwachungoderBestätigungder
SauerstoffbereitstellungeinesPatienteneingesetztwerden.
DerCheckO
2
PlusSauerstoffsensoristfürdieVerwendung
ineinerUmgebungvorgesehen,woSauerstoffkonzentratoren
gewartetund/oderrepariertwerden.DasbeinhaltetKrankenhäuser,
Altenheime,Pflegeeinrichtungen,PatientenhäuserundWartungs-und
ReparaturwerkstättenfürAtemschutzgeräte.
521176119-A
Systemübersicht
2Systemübersicht
2.1Beschreibung&Arbeitsweise
DerCheckO
2
PlusisteinSauerstoffsensorzurÜberprüfung
vonSauerstoffkonzentration,DurchflussundAusgangsdruckvon
Sauerstoffkonzentratoren.DasCheckO
2
Plusbietetaufgrund
seinesfortschrittlichenDesignseineunvergleichbareLeistungund
Zuverlässigkeit,dasdiefolgendenFeaturesundBetriebsvorteile
umfasst:
ExakteSauerstoffmessungen.
KeineFeldkalibrierungerforderlich.
BequemeMessungdesDrucksinPSIoderkPa.
Langlebiges,kompaktesDesign.
Große,einfachabzulesendeFlüssigkristallanzeige(LCD).
AbgeschirmterundverstärkterEinlassfürGasproben.
LangeLebensdauermit2AA-Batterien.
AutomatischeAbschaltungnach4Minuten.
Zeigtan,wenndieBatterieindikatorzurNeigegeht.
Selbstdiagnose.
EinfacheReinigung.
2.2BeschreibungderBestandteile
A
LCD-Anzeige
D
Gasprobeneingang
B
Modustasten
E
Gasprobenausgang
C
EIN/AUS-Schalter
F
Batteriefach
1176119-A53
2.3Symbolübersicht
FolgendeSymboleundSicherheitsbeschriftungensindaufdemCheck
O
2
Pluszufinden:
Autorisierter
Vertreterinnerhalb
derEuropäischen
Gemeinschaft
Ein-/Ausschalter
Nichtwegwefen.
BefolgenSiedie
örtlichenRichtlinien
zurEntsorgung
Modustaste
BewertetdurchETL
(IntertekTesting
Laboratories)
Batterieanzeige
niedrig
Hersteller
Durchfluss
inLiterpro
Minute(l/min)
Eindringschutz
Pfundpro
Quadratzoll
Latexfrei
Kilopascal
Seriennummer
Prozent
Katalognummer
Gasprobeneingang
Begleitdokumente
beachten
Gasprobenausgang
Gleichspannung
2.4ErklärungderBestandteile
3,5-Stellen-AnzeigeDasLCDbietetdirektesAblesen
vonSauerstoffkonzentration,GasflussundGasdruck.Aufder
LCD-AnzeigewerdenaußerdembeiBedarfdieFehlercodesangezeigt.
EIN/AUS-SchalterEin-oderAusschaltendesGeräts.
ModustastenUmschaltenzwischenderMessungdesdurcheinen
SauerstoffkonzentratorproduziertenGasesundreinemSauerstoff
(zurKalibrierungsüberprüfung).
BatterieanzeigeGibtan,wennsichdieSpannungderBatterien
unterhalbeinesnormalenBetriebszustandesbefindet.
l/minLeuchtetnebenderFlussmessung.(Wirdim
ÜberprüfungsmodusfürdieKalibrierungnichtangezeigt).
KPAAngabederDruckmessunginderEinheitKilopascal.
PSIAngabederDruckmessunginderEinheitPfundpro
Quadratzoll.
“%”SymbolBeleuchtetnebenderKonzentrationsmessung.
GasprobeneingangVerwendetfürdieAufnahmederGasprobe.
GasprobenausgangVerwendetalsAusgangfürdieGasprobe
undalsAuslöserfürdieDruckmessung,wennverstopft.
SchlauchfürGasprobeVerwendetfürdieVerbindungzu
Gasprobequellen.
2.5LieferumfangdesGeräts
Gebrauchsanweisung
SchlauchfürGasprobe
Softabdeckung
541176119-A
Sicherheit
3Sicherheit
3.1AllgemeineRichtlinien
WARNUNG!
DiesesKapitelenthältwichtigeInformationenfürden
sicherenBetriebunddiesichereVerwendungdieses
Produkts.
MöglicherweisevorhandenesZubehörerstnachdem
SiedieseAnweisungenundmöglicheszusätzliches
Anweisungsmaterial,wiezudemProduktgehörende
Benutzerhandbücher,Servicehandbücheroder
Merkblätter,vollständiggelesenundverstanden
haben.FallsdieWarnungen,Sicherheitshinweiseund
Anweisungenunverständlichsind,wendenSiesich
biteandenzuständigenHändleroderdirektanden
TechnischenKundendienstvonInvacare,bevorSie
dieAusrüstungverwenden-andernfallskanneszu
VerletzungenundSachschädenkommen.
WARNUNGZUMZUBEHÖR
DieKonstruktionunddieHerstellungder
Invacare-Produktesindsospeziell,dassausschließlich
Invacare-Zubehörverwendetwerdendarf.
ZubehörteilevonanderenHerstellernsindnicht
vonInvacaregetestetwordenundwerdenfürdie
VerwendungmitInvacare-Produktennichtempfohlen.
GEFAHR!
REDUZIERUNGDESRISIKOSVON
VERBRENNUNGEN,STROMSCHLÄGEN,
BRÄNDENODERKÖRPERVERLETZUNGEN
NichtgeeignetfürdenEinsatzbei
AnästhesieanwendungenoderfürdieMessung
derSauerstoffkonzentrationvonQuellenaußer
herkömmlicherSauerstoffkonzentratoren.
NichtgeeignetfürdieVerwendungmit
Inhalationsmitteln.DerBetriebdesCheckO
2
PlusinbrennbareroderexplosiverAtmosphärekann
zuFeuerodereinerExplosionführen.
NichtgeeignetzurVerwendungmitbrennbaren
Anästhesiegasgemischen.
SauerstoffförderteinerascheVerbrennung.Während
derVerwendungdesCheckO
2
Plusfürdie
ÜberprüfungvonSauerstoffkonzentratorendarfnicht
gerauchtwerden.
NichtzurVerwendungineinerMRI-Umgebung
geeignet.
1176119-A55
WARNUNG!
EineunsachgemäßeVerwendungdesCheckO
2
Plus
kannzufalschenSauerstoffmesswertenunddadurchzu
einerfalschenBehandlungund/oderzuSchädigungendes
Patientenkommen.BefolgenSiedieindieserAnleitung
dargestelltenVorgehensweisen.
VordemGebrauchmüssensichallePersonen
gründlichmitdenindieserAnleitungbereitgestellten
Informationvertrautmachen.Füreinesichereund
effektiveProduktleistungmüssenSiesichstrengan
alleBetriebs-undWartungsanweisungenhalten.
DieLeistungsfähigkeitdiesesProduktsistnurdann
gewährleistet,wennesinÜbereinstimmungmitden
AnweisungendesHerstellersinstalliertundbetrieben
wird.
VerwendenSiedenCheckO
2
PlusNICHTfür
dieMessungderSauerstoffkonzentrationeines
Konzentrators,wenndieDurchflussrateunterder
vomKonzentratorherstellerangegebenenLeistung
liegt;imAllgemeinen4l/minoderwenigerbei
KonzentratorenmiteinemmaximalenDurchflussvon
10l/minund1l/minoderwenigermitKonzentratoren
miteinemmaximalenDurchflussvon5l/min.
WennSiedenCheckO
2
PlusinderNähevonGeräten
verwenden,dieelektrischeFeldererzeugen,erhalten
SiemöglicherweiseungenaueMessungen.
WARNUNG!
SolltederCheckO
2
PlusjemalsFlüssigkeiten(durch
VerschüttenoderUntertauchen)ausgesetztwerden,
dannentfernenSieumgehenddieBatterienundlassen
dasGerätvollständigtrocknen.SobalddasGerät
trockenist,ersetzenSiedieBatterienundprüfenes
aufkorrektenBetrieb.
DasCheckO
2
Plusdarfniemalsautoklaviertoder
hohenTemperaturenausgesetztwerden(>60°C).
VerwendenSieKEINEEthylenoxid-Sterilisation.
SetzenSiedenCheckO
2
PlusNIEMALSDruck,
Bestrahlung,Vakuum,DampfoderChemikalienaus.
VerwendenSiefürdasCheckO
2
PlusKEINEN
höherenDruckals50psi.DieAnwendungvonDruck
über50psikannzuLecksamGerätführen,diesich
negativaufdieDurchflussleistungundaufdasAblesen
derDruckwerteauswirkenkönnen.
ReparaturenoderManipulationdesCheckO
2
Plus
überdasindenWartungsanleitungenbeschriebene
MaßhinausodervonanderenPersonen,dienicht
wievorgeschriebenvonInvacaregeschultoder
eingewiesenwordensind,kanndenordnungsgemäßen
BetriebdesGerätsbeeinträchtigen.
561176119-A
Sicherheit
VORSICHT!
ErsetzenSiedieBatterienmithochwertigenAA-Alkali-
oderLithium-Batterien.VerwendenSieKEINE
wiederaufladbarenBatterien.
UmdasGerätvorBeschädigungendurcheine
auslaufendeBatteriezuschützen,entfernenSiedie
Batterienstets,wenndasCheckO
2
Plusaufbewahrt
wird(1MonatlangnichtinGebrauch).
VermeidenSieeinHerunterfallendesCheckO
2
Plus,umsoBeschädigungenzuvermeiden,diesich
negativaufdieLeistungauswirkenkönnen.Wirdeine
BeschädigungdesGerätsvermutet,führenSie4.3
ÜberprüfungderKalibrierung,Seite58.
FührenSiekeineFremdkörperindasCheckO
2
Plus
ein.
VerwendenSiedasCheckO
2
PlusNICHTfürdie
ÜberprüfungeinesKonzentratorsbeigleichzeitig
vorhandenemBefeuchtungsgerät.DieFeuchtigkeit
einesBefeuchtungsgerätskönntedasGerät
beschädigen.
ÜberprüfenSiedenKonzentratorNICHT,während
SiedieModustastedrücken,odereswerdenfalsche
Werteabgelesen.
NachderLagerungdesGerätsunterextremheißen
oderkaltenBedingungenmussdasGassolangedurch
dasAnalysegerätfließen,bisdieinternenSensoren
dieTemperaturdesGasstromserreichen,oderman
wartetmitderVerwendungdesGeräts,bissichdas
AnalysegerätderRaumtemperaturangepassthat.
3.2Entsorgung
DiesesProduktistvoneinemumweltbewusstenHerstellergeliefert
worden,dergemäßderVerordnung2002/96/CEzurEntsorgungvon
Elektrobzw.Elektronikschrott(WEEE)arbeitet
DiesesProduktkannStoffeenthalten,diesichfürdieUmwelt
alsschädlicherweisenkönnten,fallssieanOrten(Mülldeponien)
entsorgtwerden,dienachderGesetzgebungdafürnichtgeeignet
sind.
WirbittenSie,umweltverträglichzuhandelnunddiesesProduktnach
EndeseinerLebensdauerübereinelokaleMüllverwertungsanlage
recycelnzulassen.
DieBatterienundPlatineeignensichnichtfürdieEntsorgungim
normalenHausmüll.
1176119-A57
4Bedienungsanweisungen
4.1MessungvonSauerstoff,DurchflussundDruck
ÜberprüfungvonSauerstoffkonzentration,DurchflussundDruck
einerGasprobevoneinemKonzentrator:
1.VerbindenSiedenGasprobenschlauchmitdem
GasprobeneingangvomCheckO
2
Plus.
2.BefestigenSiedasandereEndedesGasprobenschlauchsmitdem
Sauerstoffkonzentrator.
3.StartenSiedenGasflussvomCheckO
2
PlusmiteinerRatevon
1-10LiternproMinute(2LiterproMinutewirdempfohlen).
StellenSiesicher,dassderAusstoßdesKonzentratorsden
EmpfehlungendesHerstellersimBezugaufStabilitätentspricht.
4.SchaltenSiedenCheckO
2
Plusein.
5.WartenSievordemAblesenvonSauerstoffkonzentrationund
Durchfluss10Sekundenab,bissichderWertstabilisierthat.
6.UmdenDruckzuüberprüfen,deckenSiedenGasprobenausgang
währenddesGasflussesmitDaumenundFingerab.
7.WartenSie5SekundenbiszumAblesendesDrucks.
DrückenSiewährendderÜberprüfungeines
KonzentratorsNICHTdieModustasteodereswerden
falscheWerteabgelesen.
4.2WechselderDruckmaßeinheit
DasCheckO
2
PluskanndenDruckinPSIoderkPamessen.Das
CheckO
2
PlusistabWerkaufPSIeingestellt.UmschaltenaufkPa:
1.LösenSiemiteinemKreuzschlitzschraubenzieherGröße1die
SchraubedesBatteriefachdeckelsundentfernenSiedenDeckel.
2.BetätigenSiedenSchalterimBatteriefach.
3.BringenSiedenBatteriefachdeckelwiederanundziehenSiedie
SchraubedesBatteriefachdeckelswiederfest.
4.3ÜberprüfungderKalibrierung
MitdemModusfürdieKalibrierungsüberprüfungkannüberprüft
werden,obdasCheckO
2
Pluskorrektfunktioniert.Sowirddie
Kalibrierungsüberprüfungdurchgeführt:
1.SchaltenSiedasCheckO
2
Plusein.
2.VerbindenSieeineQuellemitreinemSauerstoff(99,95%)mit
demGasprobeneingang.
3.LassenSie2-5l/minGasindenCheckO
2
Plusfließen.StellenSie
sicher,dassderGasflusszumCheckO
2
Plusbeieinerstabilen
Temperaturstattfindet.
4.DrückenundhaltenSieden"Mode"Schalter.WährendSie
denSchaltergedrückthalten,solltendieWertezwischen98,5
und101,5%Sauerstoffliegen.WenndieWerteaußerhalb
dieserSpanneliegen,rufenSiebittedenKundenservicean.Im
KalibrierungsmodusleuchtetaufdemBildschirm"CAL"und
"VER"unterhalbderAnzeigefürdieSauerstoffwerte
4.4Faktoren,diegenaueMessungen
beeinträchtigen
AuswirkungenderTemperatur
DasCheckO
2
PluskompensiertdieTemperaturundarbeitet
innerhalbdesBetriebstemperaturbereichsinnerhalbder
Spezifikationen.DieDurchführungvonMessungenwährendschneller
ÄnderungenderGastemperatursolltejedochvermiedenwerden.
AuswirkungenderLuftfeuchtigkeit
DasCheckO
2
PlusverfügtübereinenFeuchtigkeitssensorfürdie
ErkennungundKompensierungderFeuchtigkeitvonGas,dasin
dasGerätgelangt.HoheMengenanFeuchtigkeit(Kondensierung)
könnendieGenauigkeitundZuverlässigkeitdesCheckO
2
Plus
beeinflussen.SovermeidenSiemöglicheSchäden:
581176119-A
Bedienungsanweisungen
VermeidenSiedenGebrauchinUmgebungenmitmehrals95%
relativerLuftfeuchtigkeit.
VerwendenSiediesesGerätNICHTineinemBeatmungskreis.
AtmenoderblasenSieNICHTindasCheckO
2
Plus.
AuswirkungenandererGase
MitdemCheckO
2
PluskönnenzweiverschiedeneArtenvon
Gasmischungengemessenwerden:
Sauerstoff,StickstoffundArgonausSauerstoffkonzentratoren.
PurerSauerstoffwährenddesModusKalibrierungsüberprüfung.
AlleanderenKonzentrationenoderKombinationenausGasenführen
mitdemCheckO
2
PluszufalschenMessergebnissen.
AuswirkungenderLuftflusses
SauerstoffkonzentratorenfunktionierennachdemPrinzipdes
EntfernensvonStickstoffausderLuftundübrigbleibtkonzentrierter
SauerstoffundArgonineinembestimmtenVerhältnis.Dieses
Betriebsprinzipkannsichändern,wenndieKonzentratorenfür
einenDurchflussamunterenEndeihresBetriebsbereichseingestellt
sind.BeiniedrigenDurchflüssengebensieeventuelleineniedrige
Sauerstoffkonzentrationaus,wiez.B.85%bis91%,wasnichtam
hohenStickstoffliegt,sondernwahrscheinlichaneinerErhöhung
desArgon.DasCheckO
2
PluserforderteinkonstantesVerhältnis
vonSauerstoffundArgon,umsoeineGenauigkeitvon+/-1,5%
Sauerstoffzugewährleisten.
VerwendenSiedasCheckO
2
PlusNICHTfürdieMessung
derSauerstoffkonzentrationeinesKonzentrators,wenndie
DurchflussrateunterdervomKonzentratorherstellerangegebenen
Leistungliegt;imAllgemeinen4l/minoderwenigerbei
KonzentratorenmiteinemmaximalenDurchflussvon10l/minund
1l/minoderwenigermitKonzentratorenmiteinemmaximalen
Durchflussvon5l/min.
1176119-A59
5Fehlercodes
5.1Fehlercodes
DasCheckO
2
PlusverfügtüberSelbstdiagnosefunktioneninder
SoftwarefürdieErkennungfehlerhafterAblesungenaußerhalbdes
normalenBetriebsbereichs.HierdieCodes,Beschreibungenund
empfohlenenMaßnahmen:
E01:SauerstoffmessungaußerhalbdesBereichsHigh(102,0%
berechnetperAlgorithmus).
EmpfohleneMaßnahme:ÜberprüfenSie,obdasCheckO
2
Plus
imkorrektenModusverwendetwird(KonzentratoroderModus
fürKalibrierungsüberprüfung).FallsderFehlercodewiederholt
angezeigtwird,führenSieeineKalibrierungsüberprüfungdurch,wie
inAbschnitt4.3diesesHandbuchserläutert.WirdderFehlercode
erneutangezeigt,wendenSiesichandenKundendienst.
E02:SauerstoffmessungaußerhalbdesBereichsLow(-2,0%
berechnetperAlgorithmus).
EmpfohleneMaßnahme:ÜberprüfenSie,obderCheckO
2
Plus
imkorrektenModusverwendetwird(KonzentratoroderModus
fürKalibrierungsüberprüfung).FallsderFehlercodewiederholt
angezeigtwird,führenSieeineKalibrierungsüberprüfungdurch,wie
inAbschnitt4.3diesesHandbuchserläutert.WirdderFehlercode
erneutangezeigt,wendenSiesichandenKundendienst.
E03:Gerätespeicherfehlerhaftoderfehlt.
EmpfohleneMaßnahme:SchickenSiedenCheckO
2
Pluszum
Herstellerzurück,umesdortreparierenzulassen.
E04:Signalmessungnichtstabil.
EmpfohleneMaßnahme:SchickenSiedenCheckO
2
Pluszum
Herstellerzurück,umesdortreparierenzulassen.
E05:DruckmessungaußerhalbdesBereichsHigh(50PSI).
EmpfohleneMaßnahme:ÜberprüfenSiedenDruckder
Gasquelle.WirdderFehlercodeerneutangezeigt,wendenSie
sichandenKundendienst.
E06:AußerhalbderBetriebstemperaturHigh(40°C).
EmpfohleneMaßnahme:DerCheckO
2
Plusistzuheiß,lassen
SiedasGerätvorderVerwendungaufRaumtemperaturabkühlen.
E07:AußerhalbderBetriebstemperaturLow(15°C).
EmpfohleneMaßnahme:DerCheckO
2
Plusistzuheiß,lassen
SiedasGerätvorderVerwendungaufRaumtemperaturabkühlen.
E08:GeräteselbstüberprüfunghateinenFehlergefunden.
EmpfohleneMaßnahme:EntfernenundersetzenSiedie
Batterien.TrittderFehlercodeerneutauf,schickenSiedenCheck
O
2
PlusandenHerstellerzurück,umesdortreparierenzulassen.
601176119-A
AustauschderBatterien
6AustauschderBatterien
6.1AustauschderBatterien
SolltendieBatterienausgewechseltwerdenmüssenleuchtet
dasSymbol
.DasSymbolleuchtetsolange,bisdieBatterien
ausgetauschtwurden.IstdieBatterieleistungzuschwach,lässt
sichderCheckO
2
Plussolangenichteinschalten,bisdieBatterien
ausgetauschtwurden.
1.LösenSiemiteinemKreuzschlitzschraubenzieherGröße1die
SchraubedesBatteriefachdeckelsBundentfernenSieden
DeckelA.
2.EntfernenSiedieBatterien.
3.LegenSiedieBatterienderAufschriftentsprechendein.
VerwendenSieKEINEwiederaufladbarenBatterien.
4.BringenSiedenBatteriefachdeckelwiederanundziehenSiedie
SchraubedesBatteriefachdeckelswiederfest.
5.WenndieBatterienfalschinstalliertwurdenoderdieBatterien
leersindgibteskeinenKontaktundderCheckO
2
Plus
funktioniertnicht.
1176119-A61
7ReinigungundWartung
7.1Reinigung
VORSICHT!
RisikovonProduktschäden
AchtenSiedarauf,dasskeineFlüssigkeitindenCheck
O
2
Pluseindringt.
TauchenSiedenCheckO
2
PlusNICHTinFlüssigkeiten
ein.
DerCheckO
2
PlusdarfNIEMALSautoklaviert
odereinerSterilisationmitMethylenoxidausgesetzt
werden.
ReinigenSiedieOberflächedesCheckO
2
Plusmiteinemfeuchten
LappenundeinermildenHandseifeodereinemGeschirrspülmittel
(pH6-8).
7.2Wartung
ErsetzenSiedieBatterienmithochwertigenAA-Alkali-oder
Lithium-Batterien.VerwendenSieKEINEwiederaufladbaren
Batterien.
UmdasGerätvorBeschädigungendurcheineauslaufendeBatterie
zuschützen,entfernenSiedieBatterienstets,wennderCheckO
2
Plusaufbewahrtwird(1MonatlangnichtinGebrauch).
LagernSiederCheckO
2
Pluszwischen-15˚Cund60˚C(5˚F-
140˚F)
621176119-A
TechnischeDaten
8TechnischeDaten
8.1TypischeProduktparameter
SAUERSTOFF
Sauerstoffmessbereich:
(voneinemKonzentrator)
20,9-96%
Sauerstoffmessgenauigkeit:±1,5%derGesamtskalabei
konstanterTemperaturund
optimalemDurchfluss*
Sauerstoffmessauflösung:0,1%Sauerstoff
SieheAuswirkungenderLuftflusses,Seite59dieser
AnleitungfürInformationenüberdieAuswirkungenvon
geringemDurchfluss.
DURCHFLUSS
Durchflussmessbereich:0-10l/min
Durchflussmessgenauigkeit:±0,2l/min
Durchflussmessauflösung:0,1l/min
DRUCKPSI
kPa
Druckmessbereich:
0,5-503,4-344
Druckmessgenauigkeit:
±0,5%±0,5%
Druckmessbereichauflösung:0,10,1biszu199,1
von200bis344
Reaktionszeit:
17Sekunden
Aufwärmzeit:<1Sekunde
Betriebstemperatur:
15°C-40°C(59°F-104°F)
Lagertemperatur:
–15°C-60°C(5°F-140°F)
Druck:
800-1000mBar
Luftfeuchtigkeit:0-95%(nichtkondensierend)
Stromanforderungen:2AAAlkalibatterien(2x1,5Volt)
Akkuhaltbarkeit:1100Stunden(16,500Lesezyklen)
NiedrigerLadezustandder
Batterie:
SymbolfürniedrigenLadezustand
aufLCD-Anzeige
Abmessungen:
3,39"x5,10"x1,00"[86,1mmx
125,5mmx25,4mm]
Gewicht:0,4Pfd.(181g)
KLASSIFIZIERUNG
Schutzvorelektrischem
Schlag:
InternbetriebenesGerät
VorWasserschützen:
Betriebsmodus:Dauerbetrieb
Sterilisation:Siehe7.1Reinigung,Seite62.
Brennbare
Anästhesiegasgemische:
NichtgeeignetzurVerwendungmit
brennbarenGemischen
Stromanforderungen:1,8-3,2V 32mW10mA
1176119-A63
9Garantie
9.1Garantie
Invacare®garantiertfürMängelfreiheitundFunktionstüchtigkeitIhres
Produkts.DieGarantieerstrecktsichaufalleFehlerundDefekte,
welchenachweisbarinfolgefehlerhafterBauart,schlechtenMaterials
odermangelhafterAusführungentstandensind.Garantieansprüche
gegenüberInvacare®kannnurderVertriebspartner,nichtder
Endkundegeltendmachen.
NichtunterdieGarantiefallennormaleAbnützung,dieFolgen
unsachgemässerBehandlungoderBeschädigung,mangelndeWartung
undfehlerhafteMontageoderInbetriebnahmedurchdenKäufer
oderDrittpersonensowieMängel,dieaufäussereUmstände
zurückzuführensind.VerschleissteilesindvonderGarantie
ausgeschlossen.DieGarantieverpflichtungerlischt,wennam
ProduktnichtvorgeseheneundnichtvomFachhändlerausgeführte
VeränderungenvorgenommenwurdenoderbeiVerwendung
ungeeigneterErsatzteile.DieGewährleistungvonInvacare®
erstrecktsichnichtaufausderMängelbeseitigungentstehende
FolgekostenwieFracht-undFahrkosten,Lohnkosten,Spesenetc.
DieGarantiefristbeträgt24Monate.
DarüberhinaussinddieGarantiebedingungenTeilderAllgemeinen
Geschäftsbedingungen,dieimjeweiligenLandgelten,indemdas
Produktgekauftwurde.
641176119-A
Sommario
Ilpresentemanualedeveesserefornitoall'utilizzatoredelprodotto.
Leggereilpresentemanualeeconservarlopereventualiconsultazioni
successive,PRIMAdiutilizzareilprodotto.
1Generalità....................................66
1.1Simboli..................................66
1.2Usoprevisto..............................66
2Panoramicadelsistema.........................67
2.1Descrizioneeprincipiodifunzionamento.........67
2.2Identificazionedeicomponenti.................67
2.3Guidadeisimboli..........................68
2.4Descrizionedeicomponenti..................68
2.5Inclusiconl'unità...........................68
3Sicurezza.....................................69
3.1GuideLineaGenerali........................69
3.2Smaltimento..............................71
4IstruzioniOperative............................72
4.1Misurazionediossigeno,flussoepressione........72
4.2Cambiamentodell'unitàdimisuradellapressione
.......................................72
4.3Proceduradiverificadellacalibratura............72
4.4Fattoricheinfluenzanolaprecisionedelle
letture...................................72
Effettidellatemperatura.....................72
Effettidell'umidità..........................73
Effettidialtrigas...........................73
Effettidelflussobasso.......................73
5Codicidierrore................................74
5.1CodicidiErrore...........................74
6Sostituzionedellebatterie.......................75
6.1Proceduradisostituzionedellebatterie..........75
7Puliziaemanutenzione.........................76
7.1Pulizia..................................76
7.2Manutenzione.............................76
8Datitecnici...................................77
8.1Parametritipicidelprodotto...................77
9Garanziacommerciale..........................78
9.1Garanziacommerciale.......................78
Condizionigenerali.........................78
Limitazionidiresponsabilità...................78
Duratadellagaranzia........................78
1Generalità
1.1Simboli
Nelpresentemanualesonoevidenziateconsimbolituttequelle
situazioninonsicureopericolosechepossonoportarealesioni
personaliodannimateriali.Vederelespiegazioniquidiseguitodi
tuttiipossibiliavvertimenti.
PERICOLO!
Pericoloindicaunasituazionedipericoloimminente
che,senonevitata,provocaildecessoolesionigravi.
ATTENZIONE!
Situazionedipericolopotenzialeche,senonevitata,
potrebbeesserecausadimorteolesionigravi.
AVVERTENZA!
Attenzioneindicaunasituazionedipotenzialepericolo
che,senonevitata,puòprovocaredanniallecosee/o
lesioninongravi.
Indicaconsigliutili,raccomandazionieinformazioniperun
usoefficaceesenzainconvenienti.
Questoprodottoèconformealladirettiva93/42/CEE
riguardanteidispositivimedici.
Ladatadilanciodiquestoprodottoèindicatanella
dichiarazionediconformitàCE.
1.2Usoprevisto
ATTENZIONE!
CheckO
2
Plusèdestinatounicamenteaverificarei
concentratoridiossigeno.
NONusareCheckO
2
Plusperilmonitoraggio
continuodell'ossigeno.
l'usodiCheckO
2
Plusèconsentitosoloalpersonaleaddestrato.
L'analizzatorediossigenoCheckO
2
Plusmisuralaconcentrazione
eilflussodell'ossigenograzieallatecnologiaultrasonicaemisurala
pressioneutilizzandounsensoreinsiliconepiezoresistivo.
L'analizzatorediossigenoCheckO
2
Plusèunostrumentoutileper
misurarelapurezza,ilflussoelapressionedell'ossigenoall'uscitadi
unconcentratorediossigeno.Nondeveessereusatodaipazienti
cuisiastataprescrittal'ossigenoterapiaenonèstatoprogettato
permonitorareoverificareinmodocontinuativol'erogazionedi
ossigenoalpaziente.
L'analizzatorediossigenoCheckO
2
Plusèstatoprogettatoper
funzionareinambientidovevengonosottopostiamanutenzione
oriparazioneiconcentratoridiossigeno.Taliambientiincludono
ospedali,unitàpostintervento,struttureperlungodegenti,domicili
deipazientiecentriperlamanutenzioneelariparazionedei
dispositivirespiratori.
661176119-A
Panoramicadelsistema
2Panoramicadelsistema
2.1Descrizioneeprincipiodifunzionamento
CheckO
2
Plusèunanalizzatorediossigenoprogettatoperverificare
laconcentrazione,ilflussoelapressioned'uscitadell'ossigenodei
concentratoridiossigeno.CheckO
2
Plusfornisceprestazionie
affidabilitàsenzaeguali,grazieallasuaprogettazioneavanzatache
includeiseguentiaspettievantaggioperativi:
Misurazioniaccuratedell'ossigeno.
Nessunanecessitàditaraturasulcampo.
PossibilitàdimisurarelapressioneinPSIokPa.
Dispositivocompattoeaffidabile.
Displayacristalliliquidi(LCD)ampioedifacilelettura.
Bocchettad'ingressogascampioneschermataerinforzata.
Lungaduratadellebatteriegraziea2pileAA.
Spegnimentoautomaticodopo4minuti.
Indicazionebatteriadebole.
Autodiagnosi.
Faciledapulire.
2.2Identificazionedeicomponenti
A
DisplayLCD
D
Ingresso
campionegas
B
Pulsantedi
modalità
E
Uscitacampione
gas
C
Pulsante
ACCESO/SPENTO
F
Sportellobatterie
1176119-A67
2.3Guidadeisimboli
CheckO
2
Plusriportaiseguentisimboliedetichettedisicurezza:
Rappresentante
autorizzatonella
Comunitàeuropea
Pulsante
Acceso/
Spento
Nongettarecon
irifiutigenerici.
Seguirelelinee
guidalocaliperlo
smaltimento
Pulsantedi
modalità
ValutatodaETL
(IntertekTesting
Laboratories)
Batteria
debole
Fabbricante Flussoinlitri
perminuto
Soloprotezionein
ingresso
Libbra-forza
perpollice
quadrato
Privodilattice Kilopascal
Numerodiserie Percentuale
Numerodicatalogo Ingresso
campionegas
Consultarei
documentidi
accompagnamento
Uscita
campionegas
Corrente
continua
2.4Descrizionedeicomponenti
Displaya3cifreinterepiùunacifradecimale:loschermo
LCDfornisceletturediretteperlaconcentrazionediossigeno,il
flussoelapressione.IldisplayLCDmostraancheicodicidierrore,
senecessario.
PulsanteACCESO/SPENTO:accendeespegneildispositivo.
Pulsantedimodalità:permettedipassaredallamisurazionedella
concentrazionedelgasprodottodaunconcentratorediossigenoa
quelladell'ossigenopuroeviceversa(perlaverificadellacalibratura).
Indicatoredibatteriadebole:indicaselatensionedellebatterie
èinferioreailivellioperativinormali.
LPM:indicatoreluminosoaccantoallamisurazionedelflusso.(Non
accesonellamodalitàdiverificadellacalibratura).
KPA:indicachelapressionevienemisuratainkilopascal.
PSI:indicachelapressionevienemisuratainlibbreforzaperpollice
quadrato.
Simbolodi"%":indicatoreluminosoaccantoallamisurazionedella
concentrazione.
Ingressocampionegas:servearicevereilcampionedigas.
Uscitacampionegas:serveperfaruscireilcampionedigasedè
dotatodiuntriggerperlamisurazionedellapressionequandotale
uscitavienechiusa.
Tubicampionegas:servonoacollegarelefontideicampionidigas.
2.5Inclusiconl'unità
Manualed’uso
Tubicampionegas
Astucciomorbido
681176119-A
Sicurezza
3Sicurezza
3.1GuideLineaGenerali
ATTENZIONE!
Questasezionecontieneinformazioniimportantiper
ilfunzionamentoelʹutilizzoinsicurezzadiquesto
prodotto.
NONUSAREquestoprodottoonessunaltro
dispositivoopzionaledisponibilesenzaprimaaver
lettoattentamenteecompresofinoinfondole
presentiistruzioniedognialtromaterialeinformativo
comemanualeutente,manualeperlamanutenzione
ofoglidiistruzioneforniticonquestoprodottoo
conIkitaggiuntivi.Nelcasoincuisegnalazioni,
avvisioistruzionifosserodidifficilecomprensione,
contattarepersonalemedico,ilrivenditoreotecnici
adeguatamentepreparatiprimadiiniziareadutilizzare
questeattrezzature;inmododaevitareognipossibile
lesionepersonaleodanno.
AVVERTENZAACCESSORI
IprodottiInvacaresonoappositamenteprogettatie
costruitiperessereutilizzatiincombinazionecon
accessoriInvacare.Accessoriprogettatidaaltri
costruttorinonsonostaticollaudatidaInvacareese
nesconsiglial'usoconiprodottiInvacare.
PERICOLO!
RIDURREILRISCHIODIUSTIONI,SCOSSE,
INCENDIOOLESIONIPERSONALI
Nonutilizzareinapplicazionianestetiche,per
misurarelaconcentrazionediossigenodafontidiverse
daitradizionaliconcentratoridiossigeno.
Nonutilizzareconagentiinalatori.Ilfunzionamentodi
CheckO
2
Plusinatmosfereinfiammabilioesplosive
puòcausareincendioesplosioni.
Nonidoneoperl’usoinpresenzadimiscele
anesteticheinfiammabili.
L'ossigenoaccelerarapidamentelacombustione.Non
fumaredurantel'usodiCheckO
2
Plusperlaverifica
deiconcentratoridiossigeno.
NonutilizzareinambienteRM.
1176119-A69
ATTENZIONE!
L'usoimpropriodiCheckO
2
Pluspuòcausareletture
nonaccuratedell’ossigenoconconseguentierrorinel
trattamentoe/odanniacaricodelpaziente.Seguirele
procedureillustratenelmanualedell’utente.
Primadell’uso,glioperatoridevonofamiliarizzarsi
perfettamenteconleinformazionicontenutenel
manualeoperativo.Lasicurezza,l’efficaciaele
prestazionidelprodottodipendonodallastretta
aderenzaalleistruzionioperative.Questoprodotto
funzionacomeprogettatosolosemessoinfunzione
secondoleistruzionioperativedelproduttore.
NONusareCheckO
2
Pluspermisurarela
concentrazionediossigenodiunconcentratore
quandoirelativiflussisonoinferioriaquelliottimali
specificatidalproduttoredelconcentratore,cioè
solitamente4LPMomenosuconcentratoriconflusso
massimodi10LPMe1LPMomenosuconcentratori
conflussomassimodi5LPM.
L'usodiCheckO
2
Plusinprossimitàdidispositiviche
generanocampielettromagneticipuòcausareletture
irregolari.
ATTENZIONE!
NelcasoincuiCheckO
2
Plussiaespostoaliquidi
derivantidaperditeoimmersione,rimuovere
immediatamentelebatterieelasciarasciugare
perfettamenteildispositivo.Unavoltaasciutto,
reinserirelebatterieeverificarecheildispositivo
funzionicorrettamente.
NONsterilizzareinautoclave,esporreCheckO
2
Plusatemperatureelevate(>60°C).
NONutilizzaremetodidisterilizzazioneaossidodi
etilene.
NONesporreCheckO
2
Plusaradiazioni,pressioni
negative,vaporeosostanzechimicheaggressive.
NONesporreCheckO
2
Plusapressionisuperioria50
PSI(3,5atm).L'esposizioneapressionisuperioria50
PSI(3,5atm)potrebbecausareperditeneldispositivo,
talidainfluenzarenegativamenteleprestazioniin
terminidiflussoeletturedellapressione.
LariparazioneolamodificadiCheckO
2
Plusdaparte
disoggettidiversidalpersonaledelservizioassistenza
Invacareautorizzatopotrebbeimpedirealprodottodi
funzionarecomeprogettato.
701176119-A
Sicurezza
AVVERTENZA!
SostituirelebatterieconpileAAalcalineoallitiodi
altaqualità.NONutilizzarebatteriericaricabili.
Quandosiprevededinonutilizzarel'unitàperoltre
30giorni,rimuoverelebatterieperproteggere
UltraMaxO2dapossibilidannidovutiafuoruscitedi
elettrolito.
EvitaredifarcadereCheckO
2
Plusperprevenire
dannichepotrebberoinfluirenegativamentesulle
sueprestazioni.Sesisospettanodannialdispositivo,
eseguirelaprocedura4.3Proceduradiverificadella
calibratura,pagina72
delmanualeoperativo.
Evitarel'ingressodimaterialeestraneonell'unità
CheckO
2
Plus.
NONusareCheckO
2
Plusperverificareconcentratori
conl'umidificatoreinsede.L'umiditàproveniente
dall'umidificatorepotrebbedanneggiareildispositivo.
NONverificareunconcentratoretenendopremutoil
pulsantedimodalitàperevitarelettureimprecise.
Dopolostoccaggioatemperatureestremamentealte
obasse,lasciarefluireilgasattraversol'analizzatore
periltemponecessarioafarraggiungereaisensori
internilatemperaturadelflussogassoso.Inalternativa,
attenderechel'analizzatoreraggiungal'equilibrioa
temperaturaambienteprimadiutilizzarlo.
3.2Smaltimento
Questoprodottoèstatofornitodalfabbricantenelrispetto
dellʹambienteeinconformitàalladirettiva2002/96/CEsuirifiutidi
apparecchiatureelettricheedelettroniche(RAEE).
Questoprodottopotrebbeconteneredellesostanzenocive
allʹambientesesmaltiteinmanieranoncorrettaolasciateinpunti
diraccoltanonappropriatienonconformiaquantoprevistodalla
legislazionevigente.
Viinvitiamoaprendervicuradell'ambienteinmodoresponsabile,
riciclandoquestoprodottoattraversoiservizidiriciclaggiodella
vostrazona,alterminedelsuoutilizzo.
Lebatterieeilcircuitostampatononsonoidoneiperlosmaltimento
comerifiutigenerici.
1176119-A71
4IstruzioniOperative
4.1Misurazionediossigeno,flussoepressione
Perverificarelaconcentrazionediossigeno,ilflussoelapressione
diuncampionedigasdaunconcentratore:
1.Collegareitubicampionegasall'ingressocampionegasdiCheck
O
2
Plus.
2.Collegarel'altraestremitàdeitubicampionegasalconcentratore
diossigeno.
3.Impostareilflussogassosonell'unitàCheckO
2
Plussuuna
portatadi1-10litriperminuto(siraccomandano2litriper
minuto).Accertarsichel'uscitadelconcentratoresiastabile
comeraccomandatodalfabbricantedeldispositivo.
4.Accenderel'unitàCheckO
2
Plus.
5.Lasciarechelaletturadell'ossigenosistabilizziperalmeno10
secondiprimadileggerelaconcentrazioneeilflussodiossigeno.
6.Perverificarelapressione,bloccarel'uscitacampionegasconil
polliceounaltroditomentreilgasstafluendo.
7.Attendere5secondifinchénonapparelaletturadellapressione
suldisplay.
NONverificareunconcentratoretenendopremutoil
pulsantedimodalitàperevitarelettureimprecise.
4.2Cambiamentodell'unitàdimisuradella
pressione
CheckO
2
PluspuòmisurarelapressioneinPSIokPa.CheckO
2
PlusèimpostatofrancofabbricapereseguiremisurazioniinPSI.Per
passareaikPa:
1.ImpiegandouncacciavitePhillipsn.1allentarelavitedello
sportellobatterieerimuoverequest'ultimo.
2.Cambiarelaposizionedeldeviatoredentroloscomparto
batterie.
3.Rimettereinsedelosportellobatterieestringerelarelativavite.
4.3Proceduradiverificadellacalibratura
CheckO
2
Plusèdotatodiunamodalitàdiverificadellacalibratura
cheserveadaccertarneilfunzionamentocorretto.Pereseguirela
verificadellacalibratura
1.Accenderel'unitàCheckO
2
Plus.
2.Collegareunafontediossigenopuro(99,95%)all'ingresso
campionegas.
3.Lasciarfluire2-5LPMdigasnell'unitàCheckO
2
Plus.Accertarsi
chelatemperaturadelgaschefluiscenell'unitàCheckO
2
Plus
siastabile.
4.Premeresenzarilasciareilpulsantedimodalità.Mentresitiene
premutoilpulsantedimodalità,lamisurazionedelgasdeve
indicarevaloridell'ossigenocompresitra98,5%e101,5%.Se
lamisurazionedelgasnonècompresainquestointervallo,
chiamarel'Assistenzaclienti.Lamodalitàdiverificadella
calibraturaèindicatadallescrittelampeggianti"CAL"e"VER"sul
display,sottoalvaloremisuratodelgas.
4.4Fattoricheinfluenzanolaprecisionedelle
letture
Effettidellatemperatura
L'unitàCheckO
2
Pluscompensalevariazioniindottedalla
temperaturaefunzionacorrettamenteentrolespecifichepertutta
lagammadellatemperaturadifunzionamento.Ètuttaviapreferibile
evitaredieseguirelemisurazioniduranterapidevariazioninella
temperaturadelgas.
721176119-A
IstruzioniOperative
Effettidell'umidità
CheckO
2
Plusèdotatodiunsensoreperrilevarel'umiditàe
compensarelevariazioniindottedaquest'ultimasulgascheentra
neldispositivo.Livellielevatidiumidità(condensa)possonotuttavia
influenzarelaprecisioneel'affidabilitàdiCheckO
2
Plus.Per
prevenireeventualidanni:
Evitarel'usoinambienticonumiditàrelativasuperioreal95%.
NONusareildispositivoneicircuitirespiratori.
NONinfondereariaosoffiarenell'unitàCheckO
2
Plus.
Effettidialtrigas
L'unitàCheckO
2
Plusèstataprogettatapermisurareduetipi
differentidimiscelegassose:
Ossigeno,azotoeargoninuscitadaiconcentratoridiossigeno.
Ossigenopurodurantelamodalitàdiverificadellacalibratura.
Ognialtraconcentrazioneocombinazionedigasdetermina
misurazionierratedell'ossigenodapartedell'unitàCheckO
2
Plus.
Effettidelflussobasso
Iconcentratoridiossigenoagisconosecondoilprincipiodirimuovere
ilgasdiazotodall'aria,lasciandoossigenoconcentratoeargon
secondounospecificorapportoossigeno/argon.Ilprincipiodi
funzionamentopuòesserealteratoquandoiconcentratorivengono
impostatisuflussiall'estremitàinferioredellalorointervallo
operativo.Abassiflussipossonoerogareunaconcentrazionedi
ossigenoinadeguata,ades.dall'85%al91%,permotividiversi
dalcontenutoelevatoinazoto,probabilmenteacausadiun
aumentonelcontenutodiargon.Pergarantireunaprecisionedi
+/-1,5%diossigeno,l'unitàCheckO
2
Plusrichiedecheilrapporto
ossigeno/argonresticostante.
NONusareCheckO
2
Pluspermisurarelaconcentrazionedi
ossigenodiunconcentratorequandoirelativiflussisonoinferiori
aquelliottimalispecificatidalproduttoredelconcentratore,cioè
solitamente4LPMomenosuconcentratoriconflussomassimodi
10LPMe1LPMomenosuconcentratoriconflussomassimodi
5LPM.
1176119-A73
5Codicidierrore
5.1CodicidiErrore
CheckO
2
Plusèdotatodiunamodalitàdiautodiagnosiintegratanel
softwarecheservearilevarelelettureerrateesterneagliintervalli
operativinormali.Codici,descrizionieazioniraccomandate:
E01:misurazionedell'ossigenoesternaall'intervalloAlto(
102,0%calcolatamediantealgoritmo).
Azioneraccomandata:verificarechel'unitàCheckO
2
Plusvenga
usatanellamodalitàcorretta(modalitàconcentratoreomodalità
diverificadellecalibratura).Seilcodicedierroreriappare,
eseguireunaverificadellacalibraturacomeindicatoallaSezione
4.3delpresentemanuale.Seilcodicedierroresiripeteancora,
contattarel'Assistenzaclienti.
E02:misurazionedell'ossigenoesternaall'intervalloBasso(-2,0%
calcolatamediantealgoritmo).
Azioneraccomandata:verificarechel'unitàCheckO
2
Plusvenga
usatanellamodalitàcorretta(modalitàconcentratoreomodalità
diverificadellecalibratura).Seilcodicedierroreriappare,
eseguireunaverificadellacalibraturacomeindicatoallaSezione
4.3delpresentemanuale.Seilcodicedierroresiripeteancora,
contattarel'Assistenzaclienti.
E03:memoriadeldispositivocorrottaomancante.
Azioneraccomandata:restituirel'unitàCheckO
2
Plusal
fabbricanteperlariparazioneinsededifabbrica.
E04:letturadelsegnaleinstabile.
Azioneraccomandata:restituirel'unitàCheckO
2
Plusal
fabbricanteperlariparazioneinsededifabbrica.
E05:misurazionedellapressioneesternaall'intervalloAlto(50
PSI).
Azioneraccomandata:verificarelapressioneconunafontedi
gasdipressionenota.Seilcodicedierroresiripete,contattare
l'Assistenzaclienti.
E06:fuoritemperaturaoperativaAlta(40SDgrC).
Azioneraccomandata:l'unitàCheckO
2
Plusètroppocalda.
Primadell'uso,raffreddareildispositivofinquasiallatemperatura
ambiente.
E07:fuoritemperaturaoperativaBassa(15SDgrC).
Azioneraccomandata:l'unitàCheckO
2
Plusètroppofredda.
Primadell'uso,riscaldareildispositivofinquasiatemperatura
ambiente.
E08:lafunzionediautodiagnosideldispositivoharilevatoun
errore.
Azioneraccomandata:rimuoverelebatterieesostituirle.Se
ilcodicedierroresiripete,restituirel'unitàCheckO
2
Plusal
fabbricanteperlariparazioneinsededifabbrica.
741176119-A
Sostituzionedellebatterie
6Sostituzionedellebatterie
6.1Proceduradisostituzionedellebatterie
Sostituirelebatteriequandosiaccendel'icona
.L'iconaresta
accesafinchélebatterienonvengonosostituite.Seillivellodi
potenzadellebatterieètroppobasso,l'unitàCheckO
2
Plusnonsi
accendefinchèquestenonvengonosostituite.
1.ImpiegandouncacciavitePhillipsn.1allentarelaviteAdello
sportellobatterieBerimuoverequest'ultimo.
2.Rimuoverelebatterie.
3.Inserirelenuovebatterieverificandonelacorrettapolarità.
NONutilizzarebatteriericaricabili.
4.Rimettereinsedelosportellobatterieestringerelarelativavite.
5.Sel'unitàCheckO
2
Plusancoranonsiaccende,verificarechele
batteriesianostateinstallatecorrettamenteesianonuove.
1176119-A75
7Puliziaemanutenzione
7.1Pulizia
AVVERTENZA!
Rischiodidanneggiamentodelprodotto
Prestarelamassimaattenzioneperevitarel'ingressodi
fluidiall'internodiCheckO
2
Plus.
NONbagnareoimmergereCheckO
2
Plusinalcun
fluido.
NONsterilizzarel'unitàCheckO
2
Plusmediante
autoclaveoesposizioneaossidodietilene.
Strofinarelesuperficiesternedell'unitàCheckO
2
Plusconunpanno
umidoesaponedelicatoperlemaniodetersivoperstoviglie(pH
6-8).
7.2Manutenzione
SostituirelebatterieconpileAAalcalineoallitiodialtaqualità.
NONutilizzarebatteriericaricabili.
Quandosiprevededinonutilizzarel'unitàperoltre30giorni,
rimuoverelebatterieperproteggereCheckO
2
Plusdapossibili
dannidovutiafuoruscitedielettrolito.
StoccareCheckO
2
Plusatemperaturecompresefra-15°Ce
+60°C.
761176119-A
Datitecnici
8Datitecnici
8.1Parametritipicidelprodotto
OSSIGENO
Intervallodimisurazione
dell'ossigeno:(daun
concentratore)
20,9–96%
Precisionedimisurazione
dell'ossigeno:
±1,5%sututtalascalaatemperatura
costanteeflussoottimale*
Risoluzionedimisurazione
dell'ossigeno:
0,1%diossigeno
VedereEffettidelflussobasso,pagina73delpresente
manualeoperativoperinformazionisuglieffettidelflusso
basso.
FLUSSO
Intervallodimisurazionedel
flusso:
0-10LPM
Precisionedimisurazione
delflusso:
±0,2LPM
Risoluzionedimisurazione
delflusso:
0,1LPM
PRESSIONEPSI
kPA
Intervallodimisurazione
dellapressione:
0,5–503,4–344
Precisionedimisurazione
dellapressione:
±0,5%±0,5%
Risoluzionedimisurazione
dellapressione:
0,1Da0,1a199,1e
da200a344
Tempodirisposta:
17secondi
Tempodiriscaldamento:
<1secondo
Temperaturadiesercizio:
Da+15°Ca+40°C
Temperaturadistoccaggio:
Da-15°Ca+60°C
Pressione:
800-1000mbar.
Umidità:
0–95%(senzacondensa)
Requisitidialimentazione:
2batteriealcalineAA(2x1,5V).
Duratadellebatterie:
1100ore(16500ciclidilettura)
Indicazionebatteriadebole:
Icona"Batt"(batteriadebole)
visualizzatasuldisplayLCD
Dimensioni:
(3.16"x5.10"x1.04")80,3mmx
129,5mmx26,4mm
Peso:
181g
CLASSIFICAZIONI:
Protezionecontrolescosse
elettriche:
apparecchiaturaconalimentazione
interna
Protezionecontrol’acqua:
Modalitàoperativa:
continua
Sterilizzazione:vedere7.1Pulizia,pagina76.
Miscelaanestetica
infiammabile:
nonutilizzareinpresenzadimiscele
anesteticheinfiammabili
Specifiche
dell'alimentazione:
1,8-3,2V 32mW10mA
1176119-A77
9Garanziacommerciale
9.1Garanziacommerciale
Condizionigenerali
Invacare®garantiscel'assenzadidifettielafunzionalitàdelleproprie
product.Lagaranziacopretuttiiguastiedidifetticomprovabili
derivantidauntipodicostruzioneerrato,dall'impiegodimaterialidi
cattivaqualitàodaun'esecuzioneinappropriata.Idirittidigaranzia
neiconfrontidiInvacare®possonoesserefattivaleresolodal
rivenditoreenondall'utentedellaproduct.
Limitazionidiresponsabilità
Lagaranziacommercialenoncoprelanormaleusura,danniderivanti
dauntrattamentoinappropriatoodanneggiamentointenzionale,da
unamanutenzioneinsufficienteedaunmontaggioerratoodalla
messainserviziodapartedell'acquirenteoditerzi,nonchédifetti
attribuibiliacircostanzeesterne.Lagaranziadecadesealprodotto
sonoapportatemodifichenonprevisteenoneseguitedalrivenditore
oincasodiutilizzodipartidiricambioinadeguate.Lagaranziadi
Invacare®noncoprecostiderivantidall'eliminazionedeldifettoquali
costidispedizioneeviaggio,costidilavoro,speseecc.
Duratadellagaranzia
Lagaranziahaunaduratadi24mesi.Lepartisoggetteadusurasono
esclusedallagaranzia.
Perulterioriaspetticommercialiedigaranziafareriferimentoalla
legislazionenazionalevigente.
781176119-A
Inhoudsopgave
Dezehandleidingdienttewordenoverhandigdaandegebruikervan
hetproduct.LeesdezehandleidingVÓÓRuhetproductgebruikten
bewaarhemvooreventueleraadplegingenindetoekomst.
1Algemeen....................................80
1.1Symbolen................................80
1.2Gebruiksdoel..............................80
2Systeemoverzicht..............................81
2.1Beschrijvingenwerkingsprincipe................81
2.2Identificatievandebestanddelen...............81
2.3Symboolgids..............................82
2.4Beschrijvingvanonderdelen...................82
2.5Meegeleverd..............................82
3Veiligheid.....................................83
3.1Algemenerichtlijnen.........................83
3.2Afvoeren.................................85
4Gebruiksinstructies.............................86
4.1Zuurstof,stromingendrukmeten..............86
4.2Drukeenhedenveranderen....................86
4.3Procedureomdekalibratieteverifiëren..........86
4.4FactorendieeencorrecteWaarde
beinvloeden...............................86
Beïnvloedingdoortemperatuur................86
Beïnvloedingdoorvochtigheid.................86
Beïnvloedingdooranderegassen...............87
Beïnvloedingdoorlagestroming................87
5Foutcodes....................................88
5.1Foutcodes................................88
6Debatterijenvervangen.........................89
6.1Batterijenvervangen........................89
7Reinigingenonderhoud.........................90
7.1Reiniging.................................90
7.2Onderhoud..............................90
8Technischegegevens...........................91
8.1Algemeneproductparameters..................91
9Garantie.....................................92
9.1Garantie.................................92
Garantietermijn............................92
1Algemeen
1.1Symbolen
Indezegebruiksaanwijzingwordensymbolengebruiktdievan
toepassingzijnopgevarenofonveiligehandelingendiekunnen
leidentotpersoonlijkletselofschadeaaneigendommen.Ziede
onderstaandeinformatievoordedefinitiesvandesymbolen.
GEVAAR!
„Gevaar”geefteenophandenzijndegevaarlijke
situatieaandie,alsdezenietwordtvermeden,de
doodofernstigletseltotgevolgheeft.
WAARSCHUWING!
Eenwaarschuwingduidtopeenmogelijkgevaarlijke
situatiedie,indiendezenietwordtvermeden,kan
leidentotoverlijdenofernstigletsel.
LETOP!
„Letop”wijstopeenmogelijkgevaarlijkesituatie
die,indienzenietwordtvoorkomen,kanleidentot
materiëleschadeofnieternstigletsel,ofbeide.
Geeftnuttigetips,adviezeneninformatievoorefficiënt,
probleemloosgebruik.
DitproductvoldoetaanRichtlijn93/42/EEGbetreffende
medischehulpmiddelen.
Deintroductiedatumvanditproductstaatvermeldinde
CE-verklaringvanovereenstemming.
1.2Gebruiksdoel
WAARSCHUWING!
DeCheckO
2
Plusdientalleenvoorhetcontroleren
vandezuurstofconcentrators.
GebruikdeCheckO
2
Plusnietvoorcontinue
zuurstofbewaking.
DeCheckO
2
Plusmagalleendooropgeleidpersoneelworden
gebruikt.
DeCheckO
2
Pluszuurstofanalysatormeetdezuurstofconcentratie
en-stromingmetbehoudvanechografieenmeetdedrukmetbehulp
vaneenpiëzo-resistievesiliciumdruksensor.
DeCheckO
2
Pluszuurstofanalysatoriseenapparaatdatwordt
gebruiktomdezuiverheid,destromingendrukvanzuurstofaan
deuitlaatvaneenzuurstofconcentratortemeten.Hetapparaatis
nietbedoeldvoorgebruikbijpatiëntendievoorgeschrevenzuurstof
krijgen,nochishetapparaatbedoeldomcontinudezuurstoflevering
aaneenpatiënttemetenoftebevestigen.
DeCheckO
2
Pluszuurstofanalysatorisbedoeldomgebruikt
tewordenineenomgevingwaardezuurstofconcentrators
wordenonderhoudenofgerepareerd.Ditomvatziekenhuizen,
verpleeghuizen,uitgebreidezorginstellingen,homesencentrawaar
ademhalingsapparatenwordenonderhoudenengerepareerd.
801176119-A
Systeemoverzicht
2Systeemoverzicht
2.1Beschrijvingenwerkingsprincipe
DeCheckO
2
Plusisiseenzuurstofanalysatordieontworpen
isomdezuurstofconcentratie,stromingenuitlaatdrukvan
zuurstofconcentratorstecontroleren.DeCheckO
2
Plus
biedtdoorzijngeavanceerdontwerpeenongeevenaarde
prestatieenbetrouwbaarheid,datdevolgendeeigenschappenen
werkingsvoordelenomvat.
Nauwkeurigezuurstofmetingen.
Geenkalibratieterplaatsevereist.
UkuntdedrukinPSIofkPameten.
Duurzaam,compactdesign.
Groot,makkelijkafleesbareLCD-display(LiquidCrystalDisplay)
Afgeschermde,versterkteinlaatpoortvanmonstergas.
Langebatterijduurmet2AA-batterijen.
Automatischeuitschakelingna4minuten.
Indicatievoorbatterijbijnaleeg.
Zelfdiagnose.
Gemakkelijkschoontemaken.
2.2Identificatievandebestanddelen
A
LCD-scherm
D
Inlaatvoor
gasmonster
B
Modustoets
E
Uitlaatvoor
gasmonster
C
AAN-/UIT-toets
F
Batterijlade
1176119-A81
2.3Symboolgids
DevolgendesymbolenenveiligheidslabelskunnenopdeCheckO
2
Plusteruggevondenworden:
Geautoriseerde
vertegenwoordiger
indeEuropeseunie
Aan/uit-toets
Nietweggooien.
Volgdeplaatselijke
richtlijneninzake
verwijdering.
Modusknop
Geevalueerddoor
ETL(IntertekTesting
Laboratories)
Batterijbijna
leeg
Fabrikant Literper
minuut
Beschermingsklasse Pondper
vierkanteinch
Latexfree
Kilopascal
Serialnumber
Procent
Catalognumber
Uitlaatvoor
gasmonster
Raadpleegde
bijgevoegde
documenten
Inlaatvoor
gasmonster
Gelijkstroom
2.4Beschrijvingvanonderdelen
31/2Digit-displayDeLCDsteltuinstaatomde
zuurstofconcentratie,gasstromingengasdrukonmiddellijkaftelezen.
DeLCDgeeftookfoutcodesweer,indiennodig.
AAN/UIT-knopHiermeeschakeltuhetapparaatinofuit.
DeknopModeHiermeeschakeltutussenhetmetenvan
degasconcentratiediedooreenzuurstofconcentratorswordt
geproduceerdenpurezuurstof(voorkalibratie).
IndicatorvoorbijnalegebatterijGeeftaandatdespanningvan
debatterijonderhetnormalebedrijfsniveauis.
LPMBrandtnaastdestromingsmeting.(Nietafgebeeldtijdensde
modusverificatievandekalibratie).
KPAGeeftdedrukweerinkilopascal.
PSIGeeftdedrukweerinpondenpervierkanteinch.
Hetsymbool“%”Brandtnaastdeconcentratie.
InlaatgasmonsterWordtgebruiktomhetgasmonsterte
ontvangen.
UitlaatgasmonsterWordtgebruiktalsuitlaatvoorhet
gasmonsterenactivatorvoorhetmetenvandedruk.
LeidingwerkgasmonsterWordtgebruiktomaantesluitenop
eenbronvoorhetgasmonster.
2.5Meegeleverd
Gebruiksaanwijzing
Leidingwerkvoorgasmonster
Zachtdeksel
821176119-A
Veiligheid
3Veiligheid
3.1Algemenerichtlijnen
WAARSCHUWING!
Ditonderdeelbevatbelangrijkeinformatievooreen
veiligewerkingengebruikvanditproduct.
GEBRUIKDITPRODUCTOFDEBESCHIKBARE
OPTIONELEAPPARATUURNIETVOORDAT
UDEZEINSTRUCTIESENHETEVENTUELE
AANVULLENDEINSTRUCTIEMATERIAAL
VOLLEDIGHEBTDOORGELEZENENBEGREPEN,
ZOALSDEGEBRUIKERSHANDLEIDINGEN,
SERVICEHANDLEIDINGENOF
INSTRUCTIEBLADENDIEBIJDITPRODUCT
OFDEOPTIONELEAPPARATUURWORDEN
VERSTREKT.ALSUNIETINSTAATBENTDE
WAARSCHUWINGEN,AANDACHTSPUNTEN
OFINSTRUCTIESTEBEGRIJPEN,NEEMDAN
CONTACTOPMETEENZORGVERLENER,
DEALEROFTECHNISCHESTAFVOORDATUDIT
APPARAATGAATGEBRUIKEN.ERKANANDERS
LETSELOFSCHADEOPTREDEN.
WAARSCHUWINGACCESSOIRES
Invacare-productenzijnspecifiekontworpenen
vervaardigdvoorgebruikincombinatiemetInvacare
accessoires.Accessoiresdiedooranderefabrikanten
zijnontworpenzijnnietgetestdoorInvacare
enwordennietaanbevolenvoorgebruikmet
Invacare-producten.
GEVAAR!
TERVERMINDERINGVANHETRISICOOP
BRANDWONDEN,ELEKTROCUTIE,BRAND
OFPERSOONLIJKLETSEL
Nietvoorgebruiktijdenshettoepassenvananesthesie
ofomzuurstofconcentratiestemetendieafkomstig
zijnvaneenanderebrondandeconventionele
zuurstofconcentrators.
Nietvoorgebruikmetinhalatiemiddelen.DeCheckO
2
Plusineenontvlambareofexplosieveatmosfeer
gebruiken,kantotbrandofeenexplosieleiden.
Nietgeschiktvoorgebruikindeaanwezigheidvaneen
ontvlambaarnarcotischmengsel.
Zuurstofversneltdeontbranding.Rookniettijdens
hetgebruikvandeCheckO
2
Plus.
NietvoorgebruikineenMRI-omgeving.
1176119-A83
WAARSCHUWING!
AlsdeCheckO
2
Plusincorrectwordtgebruikt,dan
kanditleidentotonjuistezuurstofwaardenwatopzijn
beurtkanleidentoteenincorrectebehandelingen/of
letselalsaandepatiënt.Volgdeproceduresdieindeze
gebruikershandleidingwerdenomschreven.
Gebruikersmoetenbekendzijnmetdeinformatie
vandezegebruikshandleiding.Hetisvanbelang
datmenzichstriktaandezebedieningsinstructies
houdtomeenveiligeendoeltreffendeprestatiete
garanderen.Ditproductzalenkelzoalsontworpen
werken,enkelalshetbediendwordtinnavolgingmet
debedieningsinstructiesvandefabrikant.
GebruikdeCheckO
2
Plusnietomde
zuurstofconcentratievaneenconcentratorte
metenwanneerdezeaaneenlagerewaardedanzijn
optimaleprestatiestroomt,zoalsgespecificeerddoor
defabrikantvandeconcentrator;inhetalgemeen
isdit4LPMofmindervoorconcentratorsdieeen
maximalestroomvan10LPMhebbenen1LPMof
mindervoorconcentratorsdieeenmaximalestroom
van5LPMhebben.
HetgebruikvandeCheckO
2
Plusindebuurtvan
toestellendieelektrischeveldenopwekkenkan
afwijkendewaardentotgevolghebben.
WAARSCHUWING!
AlsdeCheckO
2
Pluswordtblootgesteld
aanvloeistoffen,tengevolgevanmorsenof
onderdompeling,verwijderdanonmiddellijkde
batterijenenlaathetapparaatvolledigdrogen.
Wanneerhetapparaatdroogis,vervangdebatterijen
encontroleerofhetapparaatcorrectwerkt.
NIETDOEN:deCheckO
2
Plusautoclavenof
blootstellenaanhogetemperaturen(>65°C).
NIETDOEN:steriliserenmetethyldioxide.
NIETDOEN:deCheckO
2
Plusblootstellenaan
straling,vacuüm,stoomofbijtendechemicaliën.
NIETDOEN:deCheckO
2
Plusblootstellenaaneen
drukgroterdan50PSI.Alshetapparaatwordt
blootgesteldaaneendrukhogerdan50PSI,dankan
ditleidentotlekkendiedeprestatieophetvlakvan
destroming-endrukwaardenbeïnvloeden.
Reparatie(s)en/ofaanpassing(en)aandeCheckO
2
Plus,uitgevoerddooriemandandersdaneen
gekwalificeerdetechischemedewerkerkan
veroorzakendathetproductuitvaltofverminderde
prestatieslevertdanhetproductbedoeldisteleveren.
841176119-A
Veiligheid
LETOP!
VervangdebatterijendoorhoogwaardigeAAalkaline
oflithiumbatterijen.GebruikGEENoplaadbare
batterijen.
Alsuhetapparaatlangerdan30dagennietgebruikt,
verwijderdandebatterijenomdeCheckO
2
Plustegen
batterijlekkagetebeschermen.
VoorkomtdatudeCheckO
2
Pluslaatvallen,watkan
leidentotschadediedeprestatienegatiefbeïnvloed.
Alsuvermoedtdathetapparaatisbeschadigd,voer
dandeprocedureomdekalibratieteverifiërenuit,
zie4.3Procedureomdekalibratieteverifiëren,page
86
vandezehandleiding.
VermijddatervreemdestoffenindeCheckO
2
Plus
kunnenkomen.
GebruikdeCheckO
2
PlusNIETomeenconcentrator
meteenluchtbevochtigertecontroleren.De
vochtigheidvaneenluchtbevochtigerkanhetapparaat
beschadigen.
ControleereenconcentratorNIETterwijludeknop
Modeingedrukthoudt,anderszaldewaardeonjuist
zijn.
Alshetapparaatinextreemwarmeofkoude
omstandighedenwerdopgeslagen,laathetgasdan
voldoendelangdoordeanalysatorstromenzodat
deinternesensorenzichaandetemperatuurvan
degasstroomkunnenaanpassen,ofwachttotde
analysatoropkamertemperatuurisvoordatudeze
gebruikt.
3.2Afvoeren
Ditproductwordtgeleverddooreenmilieubewustefabrikant
diezichhoudtaanderichtlijnvandeEUbetreffendeafgedankte
elektrischeenelektronischeapparatuur(AEEArichtlijn)2002/96/CE.
Ditproductkanstoffenbevattendieschadelijkzijnvoorhetmilieuals
zeafgevoerdwordennaarplaatsen(stortplaatsen)diedaarvolgens
dewetnietgeschiktvoorzijn.
Wijhopendatuvoldoendemilieubewustbentomditproductnade
levensduurnaareenafvalverwerkingsstationtebrengen.
Debatterijenenprintplaatmogennietsamenmethethuishoudelijk
afvalwordenweggegooid.
1176119-A85
4Gebruiksinstructies
4.1Zuurstof,stromingendrukmeten
Omdezuurstofconcentratie,stromingendrukvaneengasmonster
vaneenconcentratortemeten:
1.Sluithetleidingwerkvanhetgasmonsteropdeinlaatvande
CheckO
2
Plusaan.
2.Bevestighetandereuiteindevanhetleidingwerkopde
zuurstofconcentrator.
3.LaathetgasnaardeCheckO
2
Plusstromen,aaneensnelheid
van1-10lperminuut(2lperminuutwordtaanbevolen).
Zorgdatdeuitvoervandeconcentratorstabielis,volgensde
aanbevelingenvandefabrikantvandeconcentrator.
4.SchakeldeCheckO
2
Plusin.
5.Laatdezuurstofwaardenongeveer10secondenstabiliseren
voordatudezuurstofconcentratieenstromingafleest.
6.Onderdruktecontroleren,bedektudeuitlaatvanhet
gasmonstermeteenduimofvingerterwijlhetgasaanhet
stromenis.
7.Wacht5seconden,zodatdedisplaydedrukkanweergeven.
HouddeknopModenietingedruktterwijlueen
concentratorcontroleert,anderszaldewaarde
incorrectzijn.
4.2Drukeenhedenveranderen
DeCheckO
2
PluskandedrukinPSIofkPameten.Standaardzalde
CheckO
2
PlusinPSImeten.VeranderennaarkPa:
1.Metbehulpvaneenkruiskopschroevendraaiermaaktude
batterijkleplosenverwijderdudebatterijklep.
2.Inhetbatterijvakkuntudeschakelaarveranderen.
3.Plaatsdebatterijklepterugendraaideschroevenvande
batterijklepopnieuwvast.
4.3Procedureomdekalibratieteverifiëren
DezeprocedureisvoorzienomdegoedewerkingvandeCheckO
2
Plustecontroleren.Dekalibratieprocedureuitvoeren:
1.SchakeldeCheckO
2
Plusin.
2.Sluiteenbronvanzuiverezuurstof(99,95%)opdeinlaatvoor
hetgasmonsteraan.
3.Laathetgasaan2-5LPMindeUltraMaxO
2
stromen.Zorg
dathetgasdatnaardeCheckO
2
Plusstroomteenstabiele
temperatuurheeft.
4.HouddeknopModeingedrukt.TerwijludeknopMode
ingedrukthoudt,moetdezuurstofwaardetussen98,5en
101,5%liggen.Alsdewaardenietbinnenditbereikligt,neem
dantelefonischcontactopmetdeklantenservice.Demodus
Kalibratieverifiërenwordtaangeduiddoor"CAL"en"VER"zal
ophetschermknipperen.
4.4FactorendieeencorrecteWaarde
beinvloeden
Beïnvloedingdoortemperatuur
DeCheckO
2
Pluszaldetemperatuurcompenserenenzalbinnen
hetbedrijfstemperatuurbereikvolgensdespecificatieswerken.
Echter,metentijdenssnelletemperatuurswijzigingenmoetworden
vermeden.
Beïnvloedingdoorvochtigheid
DeCheckO
2
Plusbeschiktovereenvochtigheidssensoromde
vochtigheidvanhetgasdathetapparaatbinnenkomttedetecterenen
861176119-A
Gebruiksinstructies
tecompenseren.Hogevochtigheidswaarden(condensatie)kunnen
denauwkeurigheidenbetrouwbaarheidvandeCheckO
2
Plus
beïnvloeden.Ommogelijkeschadetevoorkomen:
Vermijdgebruikinomgevingenmeteenrelatievevochtigheiddie
hogerisdan95%.
NIETDOEN:ditapparaatineenademhalingscircuitgebruiken.
NIETDOENindeCheckO
2
Plusademenofblazen.
Beïnvloedingdooranderegassen
DeCheckO
2
Plusisontworpenomtweeverschillendesoorten
gasmengelingentemeten:
Zuurstof,stikstofenargonuitzuurstofconcentrators.
PurezuurstoftijdensdemodusKalibratieverificatie.
Alleandereconcentratiesofcombinatiesvangassenzullenervoor
zorgendatdeCheckO
2
Plusdezuurstofconcentratieincorrectmeet.
Beïnvloedingdoorlagestroming
Zuurstofconcentratorswerkenophetprincipevanhet
verwijderenvanstikstofgasuitzuurstof,waardoorereen
geconcentreerdezuurstofenargonoverblijftaaneenspecifieke
verhouding.Ditwerkingsprincipekanwordengewijzigdwanneer
concentratorswordeningesteldzodatzeaandelagekantvanhun
operationelebereikstromen.Bijlagestrominggevenzeeenlage
zuurstofconcentratieaf,bijvoorbeeld85%tot91%voorandere
redenendaneenhoogstikstofgehalte,mogelijkalsgevolgvaneen
toenameaanargon.DeCheckO
2
Plusvereistdatdeverhoudingvan
zuurstoftotargonconstantblijftomeennauwkeurigheidvan+/-1,5%
tegaranderen.
GebruikdeCheckO
2
Plusnietomdezuurstofconcentratievan
eenconcentratortemetenwanneerdezeaaneenlagerewaarde
danzijnoptimaleprestatiestroomt,zoalsgespecificeerddoorde
fabrikantvandeconcentrator;inhetalgemeenisdit4LPMof
mindervoorconcentratorsdieeenmaximalestroomvan10LPM
hebbenen1LPMofmindervoorconcentratorsdieeenmaximale
stroomvan5LPMhebben.
1176119-A87
5Foutcodes
5.1Foutcodes
DeCheckO
2
Plusbeschiktovereenzelfdiagnosedieindesoftwareis
ingebouwdendiefoutewaardenbuitenhetnormalebedrijfsbereik
detecteert.Decodes,beschrijvingenenaanbevolenactieszijn:
E01:ZuurstofmetingbuitenhetbereikHi(102,0%berekend
doorhetalgoritme).
Aanbevolenactie:ControleerofdeCheckO
2
Plusinde
correctemoduswordtgebruikt(demodusConcentratorof
Kalibratieverificatie).Alsdefoutcodezichherhaalt;voertude
kalibratie-verificatieuitvolgensDeel4.3vandezehandleiding.Als
foutcodezichnogmaalsherhaalt;moetucontactopnemenmet
deklantenservice.
E02:ZuurstofmetingbuitenhetbereikLow(-2,0%berekend
doorhetalgoritme).
Aanbevolenactie:ControleerofdeCheckO
2
Plusinde
correctemoduswordtgebruikt(demodusConcentratorof
Kalibratieverificatie).Alsdefoutcodezichherhaalt;voertude
kalibratie-verificatieuitvolgensDeel4.3vandezehandleiding.Als
foutcodezichnogmaalsherhaalt;moetucontactopnemenmet
deklantenservice.
E03:Geheugenvanhetapparaatbeschadigdofontbreekt.
Aanbevolenactie:StuurdeCheckO
2
Plusterugnaardefabrikant
voorreparatie.
E04:Signaalnietstabiel.
Aanbevolenactie:StuurdeCheckO
2
Plusterugnaardefabrikant
voorreparatie.
E05:DrukmetingbuitenhetbereikHi(50PSI).
Aanbevolenactie:Controleerdedrukmetbehulpvaneengasbron
metbekendedruk.Alsfoutcodezichherhaalt;moetucontact
opnemenmetdeklantenservice.
E06:BuitenbedrijfstemperatuurHi(40¡ÆC).
Aanbevolenactie:DeCheckO
2
Plusistewarm,koelhetapparaat
afvoordatuhetgebruikt
E07:BuitenbedrijfstemperatuurLow(15¡ÆC).
Aanbevolenactie:DeCheckO
2
Plusistekoud,warmhetapparaat
opvoordatuhetgebruikt.
E08:Zelfdiagnoseheefteenfoutgevonden.
Aanbevolenactie:Verwijderenvervangdebatterijen.Stuurde
CheckO
2
Plusterugnaardefabrikantvoorreparatie.
881176119-A
Debatterijenvervangen
6Debatterijenvervangen
6.1Batterijenvervangen
Batterijenmoetenwordenvervangenwanneerhetpictogram
brandt.Ditpictogramblijftbrandentotdatdebatterijenworden
vervangen.Alsdebatterijspanningtelaagis,zaldeCheckO
2
Plus
nietinschakelentotdatdebatterijenwerdenvervangen.
1.Metbehulpvaneenkruiskopschroevendraaiermaaktude
batterijklepschroevenAlosenverwijdertudebatterijklepB.
2.Verwijderdebatterijen.
3.Plaatsnieuwebatterijen,zorgdatdepolariteitcorrectis.
GebruikGEENoplaadbarebatterijen.
4.Plaatsdebatterijklepterugendraaideschroevenvande
batterijklepopnieuwvast.
5.AlsdeCheckO
2
Plusnietinschakelt,controleerdanofde
batterijencorrectwerdengeplaatstenofdebatterijenvolzijn.
1176119-A89
7Reinigingenonderhoud
7.1Reiniging
LETOP!
Risicoopproductbeschadiging
ZorgdatergeenvloeistoffenindeCheckO
2
Plus
kunnenkomen.
NIETDOEN:deCheckO
2
Plusinvloeistoffenlaten
wekenofonderdompelen.
NIETDOEN:deCheckO
2
Plusviaautoclaafof
ethyloxidesteriliseren.
VeegdebuitenkantvandeCheckO
2
Plusmeteenvochtigedoeken
eenmildehandzeepofafwasmiddel(pH6-8)schoon.
7.2Onderhoud
VervangdebatterijendoorhoogwaardigeAAalkalineoflithium
batterijen.GEBRUIKGEENoplaadbarebatterijen.
Alsuhetapparaatlangerdan30dagennietgebruikt,verwijder
dandebatterijenomdeCheckO
2
Plustegenbatterijlekkagete
beschermen.
BewaardeCheckO
2
Plustussen-15˚Cen60˚C(5˚F140˚F)
901176119-A
Technischegegevens
8Technischegegevens
8.1Algemeneproductparameters
ZUURSTOF
Bereikvanzuurstofmeting:
(vanafeenconcentrator)
20,9-96%
Nauwkeurigheidvande
zuurstofmeting:
1,5%vandevolledigeschaalbij
constantetemperatuurenoptimale
stroming*
Oplosvermogenvande
zuurstofmeting:
0,1%zuurstof
ZieBeïnvloedingdoorlagestroming,page87vandeze
handleidingvoormeerinformatieoverdeeffectenvan
eenlagestroming.
Stroming
Bereikvanstromingmeting:
0-10LPM
Nauwkeurigheidvande
stromingmeting:
±0,2LPM
Oplosvermogenvande
stromingmeting:
0,1LPM
DRUK
PSI
KPA
Bereikvandrukmeting:
0,5-503,4-344
Nauwkeurigheidvande
drukmeting:
±0,5%±0,5%
Oplosvermogenvande
drukmeting:
0,10,1tot1991van
200tot344
Responstijd:
=<17seconden
Opwarmtijd:<1seconde
Bedrijfstemperatuur:15˚C40˚C(59˚F-104˚F)
Opslagtemperatuur:-15˚C60˚C(5˚F-140˚F)
Druk:
800-1000mBars
Vochtigheid:
0tot95%(nietcondenserend)
Voedingsvereisten:
2AAalkalinebatterijen(2x1,5Volt)
Levensduurbatterij:
>1.100uur(16.500cycli).
Indicatievoorbijnalege
batterij:
"LowBattery"pictogramopLCD
Afmetingen:
3,16"x5,10"x1,04"[80,3mmx
129,5mmx26,4mm]
Gewicht:0,4lbs(181g)
CLASSIFICATIES:
Beschermingtegen
elektrischeschok:
Interngevoedapparaat
Beschermingtegenwater:
Gebruikswijze:Continu
Sterilisatie:Zie7.1Reiniging,page90.
Ontvlambaarnarcotisch
mengsel:
Nietgeschiktvoorgebruikinde
aanwezigheidvaneenontvlambaar
narcotischmengsel
Voedingsspecificaties:1,8-3,2V 32mW10mA
1176119-A91
9Garantie
9.1Garantie
Invacare®garandeertueendefectvrijeengoedfunctionerende
product.Degarantieheeftbetrekkingopallefoutenendefecten
dieaantoonbaaralsgevolgvaneenfoutieveconstructie,slechte
materialenofeengebrekkigeuitvoeringzijnontstaan.Garantieclaims
jegensInvacare®kanalleendeverkooppartnerennietdeeigenaar
vanhetproductindienen.
Normaleslijtage,degevolgenvaneenondeskundigebehandelingof
beschadiging,slechtonderhoudenfoutievemontageofhetgebruik
doordekoperofderdenengebrekendiedoorbuitenomstandigheden
zijnveroorzaakt,vallennietonderdegarantie.Degarantieplicht
vervalt,alsernietvoorzieneennietdoordespeciaalzaakuitgevoerde
wijzigingenaandeproductwerdenaangebrachtofbijgebruikvan
ongeschiktevervangingsonderdelen.DegarantievanInvacare®dekt
geenkostendieontstaanuitreparaties,zoalsvracht-enreiskosten,
loonkosten,onkosten,enz.
Garantietermijn
Degarantietermijnbedraagt24maanden.Slijtagedelenzijnvande
garantieuitgesloten.
Determijnenenconditieszijnonderdeelvandealgemenerichtlijnen
encondities,specifieknaardeindividuelelandenwaarditprodukt
isverkocht.
921176119-A
Notes
Notes
UnitedKingdomInvacareLimitedPencoedTechnologyPark,Pencoed,BridgendCF355HZTel:(44)(0)1656776
222Fax:(44)(0)1656776220www.invacare.co.uk[email protected]
Ireland
InvacareIrelandLtdUnit5SeatownBusinessCampusSeatownRoadSwordsCountyDublin
IrelandTel:(353)18107084Fax:(353)18107085www.invacare.ie[email protected]
France
InvacarePoirierSASRoutedeStRochF-37230FondettesTel:(33)(0)247626466Fax:(33)
(0)247421224www.invacare.fr[email protected]
Switzerland
InvacareAGBenkenstrasse260CH-4108WitterswilTel.:(41)(0)614877080Fax.:(41)
(0)614877081www.invacare.ch[email protected]
Deutschland
InvacareGmbHAlemannenstraße10D-88316IsnyTel:(49)(0)75627000Fax:(49)(0)75
6270066www.invacare.de[email protected]
España
InvacareSAc/Arenys/nPolígonIndustrialdeCelràE-17460Celrà(Girona)Tel:(34)(0)97249
3200Fax:(34)(0)972493220www.invacare.es[email protected]
Belgium&LuxemburgInvacarenvAutobaan22B-8210LoppemTel:(32)(0)50831010Fax:(32)(0)50831011
[email protected]www.invacare.be
Nederland
InvacareBVCelsiusstraat46NL-6716BZEdeTel:(31)(0)318695757Fax:(31)(0)318695
758[email protected]www.invacare.nl[email protected]
Österreich
InvacareAustriaGmbHHerzogOdilostrasse101A-5310MondseeTel:(43)623255350Fax:
(43)623255354[email protected]www.invacare.at
ItaliaInvacareMeccSans.r.l.ViadeiPini62I-36016Thiene(VI)Tel:(39)0445380059Fax:(39)
0445380034[email protected]www.invacare.it
AuthorizedRepresentative
QNETBV
Hommerterweg286
6436AMAmstenrade
TheNetherlands
Manufacturer
Maxtec
6526S.CottonwoodStreet
SaltLakeCity,UT84107
USA
Tel:801–266–5300
www.maxtecinc.com
Distributedby:
InvacareCorporation
USA
OneInvacareWay
Elyria,OhioUSA
44036–2125
800–333–6900
Canada
570MathesonBlvd.EUnit8
Mississauga,OntarioL4Z4G4
905–890–8300
www.invacare.com
1176119-A2012-05-15
*1176119A*

Documenttranscriptie

Invacare® Check O2 Plus™ IRC450 EN Oxygen Analyzer User Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 FR Analyseur d’oxygene Manuel d'utilisation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 ES Analizador de oxígeno Manual del usuario . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 DE Sauerstoffsensor Gebrauchsanweisung . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 IT Analizzatore di ossigeno Manuale d’uso . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 NL Zuurstofanalysator Gebruiksaanwijzing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 This manual MUST be given to the user of the product. BEFORE using this product, read this manual and save for future reference. ©2012 Invacare®Corporation All rights reserved. Republication, duplication or modification in whole or in part is prohibited without prior written permission from Invacare. Trademarks are identified by ™and ®. All trademarks are owned by or licensed to Invacare Corporation or its subsidiaries unless otherwise noted. 6.1 Contents This manual MUST be given to the user of the product. BEFORE using this product, read this manual and save for future reference. 1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 1.1 Symbols. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 1.2 Intended Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2 System Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2.1 Description and Principle of Operation . . . . . . . . . . . 5 2.2 Component Identification . . . . . . . . . . . . . . . . . . . . . 5 2.3 Symbol Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 2.4 Component Description. . . . . . . . . . . . . . . . . . . . . . 6 2.5 Included with Your Unit . . . . . . . . . . . . . . . . . . . . . . 6 3 Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 3.1 General Guidelines. . . . . . . . . . . . . . . . . . . . . . . . . . 7 3.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 4 Operating Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1 Oxygen, Flow and Pressure Measurement . . . . . . . . . 4.2 Switching Pressure Units of Measure . . . . . . . . . . . . . 4.3 Calibration Verification Procedure . . . . . . . . . . . . . . 4.4 Factors Influencing Accurate Readings . . . . . . . . . . . . Effects of Temperature. . . . . . . . . . . . . . . . . . . . . . . Effects of Humidity. . . . . . . . . . . . . . . . . . . . . . . . . . Effects of Other Gases . . . . . . . . . . . . . . . . . . . . . . . Effects of Low Flow . . . . . . . . . . . . . . . . . . . . . . . . . 5 Error Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 5.1 Error Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 6 Changing the Batteries . . . . . . . . . . . . . . . . . . . . . . . . . 13 10 10 10 10 10 10 10 11 11 Battery Replacement Procedure . . . . . . . . . . . . . . . . 13 7 Cleaning and Maintenance . . . . . . . . . . . . . . . . . . . . . . . 14 7.1 Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 7.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 8 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 8.1 Product Parameters . . . . . . . . . . . . . . . . . . . . . . . . . 15 9 Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 9.1 Warranty — North America . . . . . . . . . . . . . . . . . . 16 9.2 Warranty — Europe . . . . . . . . . . . . . . . . . . . . . . . . 17 1 General 1.1 Symbols Signal words are used in this manual and apply to hazards or unsafe practices which could result in personal injury or property damage. See the information below for definitions of the signal words. DANGER! – Danger indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. 1.2 Intended Use WARNING! – The Check O2 Plus is for checking oxygen concentrators only. – DO NOT use the Check O2 Plus for continuous oxygen monitoring. The Check O2 Plus is for use only by trained personnel. The Check O2 Plus Oxygen Analyzer measures oxygen concentration and flow using ultrasound technology and measures pressure using a piezoresistive silicon pressure sensor. WARNING! – Warning indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. The Check O2 Plus Oxygen Analyzer is a tool used to measure oxygen purity, flow and pressure at the outlet of an oxygen concentrator. It is not intended to be used by patients who are prescribed oxygen, nor is it intended to continuously monitor or confirm oxygen delivery to a patient. CAUTION! – Caution indicates a potentially hazardous situation which, if not avoided, may result in property damage or minor injury or both. The Check O2 Plus Oxygen Analyzer is intended to be used in an environment where oxygen concentrators are being serviced or repaired. This includes Hospitals, Nursing Homes, Extended Care Facilities, Patient Homes, and Respiratory Device Service and Repair Centers. Gives useful tips, recommendations and information for efficient, trouble-free use. This product complies with Directive 93/42/EEC concerning medical devices. The launch date of this product is stated in the CE declaration of conformity. 4 1176119-A System Overview 2 System Overview 2.2 Component Identification 2.1 Description and Principle of Operation The Check O2 Plus is an oxygen analyzer designed to check the oxygen concentration, flow and outlet pressure of oxygen concentrators. The Check O2 Plus provides unparalleled performance and reliability from its advanced design that includes the following features and operational benefits: • • • • • • • • • • • Accurate oxygen measurements No in-field calibration required Convenient ability to measure pressure in PSI or kPa Durable, compact design Large, easy-to-read, liquid crystal display (LCD) Shielded, reinforced sample gas inlet port Long battery life with 2 AA batteries Auto-off after 4 minutes Low battery indication Self-diagnostics Easy to clean 1176119-A A LCD Display D Gas Sample Inlet B Mode Button E Gas Sample Outlet C On/Off Button F Battery Door 5 2.3 Symbol Guide 2.4 Component Description The following symbols and safety labels are found on the Check O2 Plus: 3 1/2 Digit Display — The LCD provides direct readout of oxygen concentration, gas flow and gas pressure. The LCD also displays error codes as necessary. Authorized representative in the European Community On/off button Do not throw away. Follow local guidelines for disposal. Mode button Evaluated by ETL (Intertek Testing Laboratories) Low battery Manufacturer Liter per minute flow Ingress protection Pounds per square inch ON/OFF Button — Turns the device on or off. Mode Button — Switches between measuring the concentration of gas produced by an oxygen concentrator and pure oxygen (for calibration verification). Low Battery Indicator — Indicates the voltage of the batteries is below normal operating levels. LPM — Illuminated next to the flow measurement. (not shown when in calibration verification kPA — Indicates the pressure measurement is in units of kilopascals. PSI — Indicates the pressure measurement is in units of pounds per square inch. “%” symbol — Illuminated next to the concentration measurements. Gas Sample Inlet — Used to receive the gas sample. Latex free Kilopascals Gas Sample Outlet — Used as an outlet for the gas sample and as a trigger for pressure measurement when occluded. Serial number Percent Gas Sample Tubing — Used to connect to gas sample sources. Catalog number Gas Sample Inlet 2.5 Included with Your Unit Consult accompanying documents Gas Sample Outlet • User Manual • Gas Sample Tubing • Soft Cover Direct current 6 1176119-A Safety 3 Safety 3.1 General Guidelines WARNING! – This section contains important information for the safe operation and use of this product. – DO NOT USE THIS PRODUCT OR ANY AVAILABLE OPTIONAL EQUIPMENT WITHOUT FIRST COMPLETELY READING AND UNDERSTANDING THESE INSTRUCTIONS AND ANY ADDITIONAL INSTRUCTIONAL MATERIAL SUCH AS USER MANUALS, SERVICE MANUALS OR INSTRUCTION SHEETS SUPPLIED WITH THIS PRODUCT OR OPTIONAL EQUIPMENT. IF YOU ARE UNABLE TO UNDERSTAND THE WARNINGS, CAUTIONS OR INSTRUCTIONS, CONTACT A HEALTHCARE PROFESSIONAL, DEALER OR TECHNICAL PERSONNEL BEFORE ATTEMPTING TO USE THIS EQUIPMENT - OTHERWISE, INJURY OR DAMAGE MAY OCCUR. ACCESSORIES WARNING – Invacare products are specifically designed and manufactured for use in conjunction with Invacare accessories. Accessories designed by other manufacturers have not been tested by Invacare and are not recommended for use with Invacare products. 1176119-A DANGER! TO REDUCE THE RISK OF BURNS, ELECTROCUTION, FIRE OR INJURY TO PERSONS – Not for use in anesthesia applications or for measuring oxygen concentration from any sources other than conventional oxygen concentrators. – Not for use with inhalation agents. Operating the Check O2 Plus Plus in flammable or explosive environments may result in fire or explosion. – Not suitable for use in the presence of flammable anesthetic mixtures. – Oxygen rapidly accelerates combustion. Do not smoke while using the Check O2 Plus for checking oxygen concentrators. – NOT for use in an MRI environment. 7 WARNING! Improper use of the Check O2 Plus can cause inaccurate oxygen readings leading to improper treatment and/or patient harm. Follow the procedures outlined in this user manual. – Users must become thoroughly familiar with the information contained in this User Manual before use. Strict adherence to the operating instructions is necessary for safe, effective product performance. This product will perform only as designed if operated in accordance with the manufacturer’s operating instructions. – DO NOT use the Check O2 Plus to measure the oxygen concentration of a concentrator when flowing at rates lower than its optimal performance as specified by the concentrator manufacturer; generally 4 LPM or less on concentrators that have a maximum flow of 10 LPM, and 1 LPM or less on concentrators that have a maximum flow of 5 LPM. – Use of the Check O2 Plus near devices that generate electrical fields may cause erratic readings. – If the Check O2 Plus is ever exposed to liquids from spills or immersion, immediately remove the batteries and let the device dry completely. When dry, replace the batteries and check for proper operation. 8 WARNING! – DO NOT autoclave or expose the Check O2 Plus to high temperatures (>60° C [140° F]). – DO NOT use ethylene oxide sterilization. – DO NOT expose the Check O2 Plus to irradiation, vacuum, steam, or harsh chemicals. – DO NOT expose the Check O2 Plus to pressure greater than 50 psi. Exposure to pressure above 50 psi could cause leaks in the device which may adversely affect performance in flow and pressure readings. – Repair or alteration of the Check O2 Plus by anyone other than a qualified technician could cause the product to fail to perform as designed. 1176119-A Safety CAUTION! – Replace the batteries with high quality AA Alkaline or Lithium batteries. DO NOT use rechargeable batteries. – When not in use for periods greater than 30 days remove the batteries to protect the Check O2 Plus from potential battery leakage. – Avoid dropping the Check O2 Plus to prevent damage which may adversely affect its performance. If damage to the device is suspected, perform 4.3 Calibration Verification Procedure, page 10. – Avoid foreign matter entry into the Check O2 Plus . – DO NOT use the Check O2 Plus to check a concentrator with a humidifier in place. Humidity could damage the device. – DO NOT check a concentrator while holding the mode button or the reading will be inaccurate. – Following storage in extremely hot or cold conditions, allow the gas to flow through the analyzer long enough for the internal sensors to reach the gas stream temperature, or wait for the analyzer to equilibrate to room temperature before use. 1176119-A 3.2 Disposal This product has been supplied from an environmentally aware manufacturer that complies with the Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/CE. This product may contain substances that could be harmful to the environment if disposed of in places (landfills) that are not appropriate according to legislation. Please be environmentally responsible and recycle this product through your recycling facility at its end of life. The batteries and circuit board are not suitable for regular trash disposal. 9 4 Operating Instructions 4.1 Oxygen, Flow and Pressure Measurement To check oxygen concentration, flow and pressure of a gas sample from a concentrator: 1. 2. 3. 4. 5. 6. 7. Connect the gas sample tubing to the gas sample inlet of the Check O2 Plus. Attach the other end of the gas sample tubing to the oxygen concentrator. Initiate the flow of gas to the Check O2 Plus at a rate of 1-10 liters per minute (2 liters per minute is recommended). Ensure the concentrator’s output is stable per the concentrator manufacturer’s recommendations. Turn on the Check O2 Plus. Allow the oxygen reading to stabilize for approximately 10 seconds before reading the oxygen concentration and flow. To check pressure, cover the gas sample outlet with thumb or finger while gas is flowing. Wait 5 seconds for the display to read pressure. DO NOT hold the mode button while checking a concentrator or the reading will be inaccurate. 4.3 Calibration Verification Procedure A calibration verification mode is provided to verify that the Check O2 Plus is functioning properly. To perform the calibration verification: 1. 2. 3. 4. Turn on the Check O2 Plus. Connect a source of pure oxygen (≥99.95%) to the gas sample inlet Flow 2–5 LPM of gas into the Check O2 Plus. Ensure that the gas flowing to the Check O2 Plus is at a stable temperature. Press and hold the mode button. While holding the mode button, the gas measurement should read between 98.5 and 101.5% oxygen. If the gas measurement is not within this range, call Customer Service. Calibration verification mode is indicated by “CAL” and “VER” flashing on screen beneath the gas measurement. 4.4 Factors Influencing Accurate Readings Effects of Temperature The Check O2 Plus compensates for temperature and will perform within specifications throughout the operating temperature range. However, taking measurements during rapid changes in gas temperature should be avoided. 4.2 Switching Pressure Units of Measure Effects of Humidity The Check O2 Plus can measure pressure in PSI or kPa. The Check O2 Plus is factory set to measure in PSI. To switch to kPa: The Check O2 Plus has a humidity sensor to detect and compensate for the humidity of gas entering the device. However, high levels (condensing) of humidity can affect the accuracy and reliability of the Check O2 Plus. To prevent possible damage: 1. 2. 3. 10 Using a #1 Phillips screwdriver loosen the battery door screw and remove the battery door. Toggle the switch inside the battery compartment. Replace the battery door and tighten the battery door screw. • Avoid usage in environments of greater than 95% relative humidity • DO NOT use this device in a breathing circuit • DO NOT breathe or blow into the Check O2 Plus 1176119-A Operating Instructions Effects of Other Gases Effects of Low Flow The Check O2 Plus is designed to measure two different types of gas mixtures: Oxygen concentrators function on the principle of removing nitrogen gas from air, leaving concentrated oxygen and argon at a specific oxygen to argon ratio. This operating principle may be altered when concentrators are set to flow at the low end of their operational range. At low flows they may output a low oxygen concentration, e.g. 85% to 91%, for reasons other than high nitrogen, possibly due to an increase in argon content. The Check O2 Plus requires that the ratio of oxygen to argon remain constant in order to guarantee an accuracy of +/-1.5% oxygen. • Oxygen, nitrogen and argon from oxygen concentrators • Pure oxygen during calibration verification mode Any other concentrations or combinations of gases will cause the Check O2 Plus to measure oxygen concentration incorrectly. • DO NOT use the Check O2 Plus to measure the oxygen concentration of a concentrator when flowing at rates lower than its optimal performance as specified by the concentrator manufacturer; generally 4 LPM or less on concentrators that have a maximum flow of 10 LPM, and 1 LPM or less on concentrators that have a maximum flow of 5 LPM. 1176119-A 11 5 Error Codes 5.1 Error Codes The Check O2 Plus has self diagnostic features built into the software to detect faulty readings outside of normal operating ranges. The codes, descriptions and recommended actions are: • E01: Oxygen measurement out of range Hi ( ≥ 102.0% calculated by algorithm). Recommended Action: Verify that the Check O2 Plus is being used in the correct mode (Concentrator or Calibration Verification mode). If error code repeats; perform a calibration verification. If error code repeats again; Call Service Provider. • E02: Oxygen measurement out of range Low ( ≤ -2.0% calculated by algorithm). Recommended Action: Verify that the Check O2 Plus is being used in the correct mode (Concentrator or Calibration Verification mode). If error code repeats; perform a calibration verification. If error code repeats again; Call Service Provider. • E03: Device memory corrupt or missing. Recommended Action: Call Service Provider. 12 • E04: Signal reading not stable. Recommended Action: Call Service Provider. • E05: Pressure measurement out of Range Hi ( ≥ 50 PSI). Recommended Action: Check the pressure on a known gas source pressure. If error code repeats; Call Service Provider. • E06: Outside of operating temperature Hi ( ≥ 40° C). Recommended action: The Check O2 Plus is too hot, cool the device closer to room temperature before use. • E07: Outside of operating temperature Low ( ≤ 15° C). Recommended action: The Check O2 Plus is too cold, warm the device closer to room temperature before use. • E08: Device self check found error. Recommended Action: Remove and replace the batteries. If error code repeats; Call Service Provider. 1176119-A Changing the Batteries 6 Changing the Batteries 1. 6.1 Battery Replacement Procedure 2. 3. Batteries should be changed when the icon illuminates. The icon will remain lit until the batteries are changed. If the battery power level is too low the Check O2 Plus will not power on until the batteries are changed. 4. 5. 1176119-A Using a #1 Phillips screwdriver loosen the battery door screw A and remove the battery door B. Remove the batteries. Insert new batteries ensuring correct polarity. DO NOT use rechargeable batteries. Replace the battery door and tighten the battery door screw. If the Check O2 Plus does not power on when done verify the batteries are installed correctly and that the batteries are fresh. 13 7 Cleaning and Maintenance 7.2 Maintenance 7.1 Cleaning • When not in use for periods greater than 30 days, remove the CAUTION! Use caution to prevent any fluid from entering the Check O2 Plus . – DO NOT soak or immerse the Check O2 Plus in fluid. – DO NOT autoclave or expose the Check O2 Plus to ethylene oxide sterilization. • Replace the batteries with high quality AA Alkaline or Lithium batteries. DO NOT use rechargeable batteries. batteries to protect the unit from potential battery leakage. • Store the Check O2 Plus between –15° C and 60° C (5° F — 140° F) Wipe down the exterior surfaces of the Check O2 Plus with a moist cloth and mild hand or dish soap (pH 6–8). 14 1176119-A Technical Data 8 Technical Data 8.1 Product Parameters OXYGEN Oxygen Measurement Range: (from a concentrator) Oxygen Measurement Accuracy: Oxygen Measurement Resolution: 20.9 - 96% ±1.5 % of full scale at constant temperature and optimal flow* 0.1% Oxygen See Effects of Low Flow, page 11 of this operating manual for information on the effects of low flow. FLOW Flow Measurement Range: Flow Measurement Accuracy: Flow Measurement Resolution: PRESSURE Pressure Measurement Range: Pressure Measurement Accuracy: 1176119-A 0 - 10 LPM ±0.2 LPM 0.1 LPM PSI 0.5 - 50 KPA 3.4 - 344 ±0.5% ±0.5% Pressure Measurement Resolution: Response Time: Warm-up Time: Operating Temperature: Storage Temperature: Pressure: Humidity: Power Requirements: Battery Life: Low Battery Indication: Dimensions: 0.1 0.1 up to 199, 1 from 200 to 344 ≤ 17 seconds < 1 second 59° F - 104° F (15° C - 40° C) 5° F - 140° F (-15° C - 60° C) 800 - 1000 mBars 0 - 95% (non-condensing) 2-AA Alkaline batteries (2 x 1.5 volts) ≥1,100 hours (16,500 read cycles) “Low Battery” icon displayed on LCD 3.16” x 5.10” x 1.04” (80.3 mm x 129.5 mm x 26.4 mm) 0.4 lbs (181 grams) Weight: CLASSIFICATIONS Protection against Internally powered equipment electrical shock: Protection against water: Mode of operation: Continuous Sterilization: See 7.1 Cleaning, page 14. Flammable Not for use in presence of flammable anaesthetic mixture: anaesthetic mixtures Power specification: 1.8 - 3.2 V 32 mW 10mA 15 9 Warranty 9.1 Warranty — North America PLEASE NOTE: THE WARRANTY BELOW HAS BEEN DRAFTED TO COMPLY WITH FEDERAL LAW APPLICABLE TO PRODUCTS MANUFACTURED AFTER JULY 4, 1975. This warranty is extended only to the original purchaser/user of our products. This warranty gives you specific legal rights and you may also have other legal rights which vary from state to state. Invacare warrants this product to be free from defects in materials and workmanship for three years for the original purchaser. If within such warranty period any such product shall be proven to be defective, such product shall be repaired or replaced, at Invacare’s option. This warranty does not include any labor or shipping charges incurred in replacement part installation or repair of any such product. Invacare’s sole obligation and your exclusive remedy under this warranty shall be limited to such repair and/or replacement. For warranty service, please contact the dealer from whom you purchased your Invacare product. In the event you do not receive satisfactory warranty service, please write directly to Invacare at the address on the back page. Provide dealer’s name, address, model number, date of purchase, indicate nature of the defect and, if the product is serialized, indicate the serial number. Invacare Corporation will issue a return authorization. The defective unit or parts must be returned for warranty inspection using the serial number, when applicable, as identification within thirty (30) days of return authorization date. DO NOT return products to our factory without our prior consent. C.O.D. shipments will be refused; please prepay shipping charges. LIMITATIONS AND EXCLUSIONS: THE WARRANTY SHALL 16 NOT APPLY TO PROBLEMS ARISING FROM NORMAL WEAR OR FAILURE TO ADHERE TO THE ENCLOSED INSTRUCTIONS. IN ADDITION, THE FOREGOING WARRANTY SHALL NOT APPLY TO SERIAL NUMBERED PRODUCTS IF THE SERIAL NUMBER HAS BEEN REMOVED OR DEFACED; PRODUCTS SUBJECTED TO NEGLIGENCE, ACCIDENT, IMPROPER OPERATION, MAINTENANCE OR STORAGE; OR PRODUCTS MODIFIED WITHOUT INVACARE’S EXPRESS WRITTEN CONSENT INCLUDING, BUT NOT LIMITED TO: MODIFICATION THROUGH THE USE OF UNAUTHORIZED PARTS OR ATTACHMENTS: PRODUCTS DAMAGED BY REASON OF REPAIRS MADE TO ANY COMPONENT WITHOUT THE SPECIFIC CONSENT OF INVACARE; PRODUCTS DAMAGED BY CIRCUMSTANCES BEYOND INVACARE’S CONTROL; PRODUCTS REPAIRED BY ANYONE OTHER THAN AN INVACARE DEALER, SUCH EVALUATION SHALL BE SOLELY DETERMINED BY INVACARE. THE FOREGOING EXPRESS WARRANTY IS EXCLUSIVE AND IN LIEU OF ANY OTHER EXPRESS WARRANTIES WHATSOEVER, WHETHER EXPRESS OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND THE SOLE REMEDY FOR VIOLATIONS OF ANY WARRANTY WHATSOEVER, SHALL BE LIMITED TO REPAIR OR REPLACEMENT OF THE DEFECTIVE PRODUCT PURSUANT TO THE TERMS CONTAINED HEREIN. THE APPLICATION OF ANY IMPLIED WARRANTY WHATSOEVER SHALL NOT EXTEND BEYOND THE DURATION OF THE EXPRESS WARRANTY PROVIDED HEREIN. INVACARE SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES WHATSOEVER. THIS WARRANTY SHALL BE EXTENDED TO COMPLY WITH STATE/PROVINCIAL LAWS AND REQUIREMENTS. 1176119-A Warranty 9.2 Warranty — Europe Invacare® guarantees that their products are free from defects and are fully functional. The warranty covers all faults and defects which are verifiably attributable to faulty construction, substandard materials or poor workmanship. Warranty claims against the manufacturer may only be made by the distributor and not by the user of the product. The warranty does not cover normal wear and tear, the consequences of improper handling or damage, poor maintenance and incorrect assembly or commissioning by the purchaser or a third person or faults which are attributable to circumstances beyond our control. Wearing parts are not covered by the guarantee. The warranty is voided if modifications are made to the product which were not authorised and not performed by the specialist dealer or if inappropriate accessories or spare parts are used. The warranty does not cover consequential costs arising from the rectification of defects such as freight and travel expenses, labour costs, fees etc. The term of the warranty is 24 month. Furthermore, the terms and conditions are part of the general terms and conditions particular to the individual countries in which this product is sold. 1176119-A 17 Notes Sommaire 6 Remplacement des piles . . . . . . . . . . . . . . . . . . . . . . . . 29 6.1 Procédure de remplacement des piles . . . . . . . . . . . . 29 Ce manuel DOIT être remis à l'utilisateur du produit. Lire ce manuel AVANT d'utiliser ce produit, et le conserver en cas de besoin. 7 Nettoyage et entretien . . . . . . . . . . . . . . . . . . . . . . . . . 30 7.1 Nettoyage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 7.2 Entretien . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 8 Caractéristiques techniques . . . . . . . . . . . . . . . . . . . . . 31 8.1 Paramètres Caractéristiques Du Produit . . . . . . . . . . 31 9 Garantie . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 9.1 Garantie limitée – Amérique du Nord . . . . . . . . . . . . 32 9.2 Garantie . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 1 Généralités . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 1.1 Symboles. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 1.2 Utilisation conforme. . . . . . . . . . . . . . . . . . . . . . . . . 20 2 Aperçu du système . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.1 Description et Principe de fonctionnement . . . . . . . . 2.2 Identification des composantes . . . . . . . . . . . . . . . . . 2.3 Guide des symboles . . . . . . . . . . . . . . . . . . . . . . . . 2.4 Description des composantes . . . . . . . . . . . . . . . . . 2.5 L’emballage comprend . . . . . . . . . . . . . . . . . . . . . . . 3 Sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 3.1 Mises en garde. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 3.2 Elimination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 4 Mode d'emploi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1 Mesure du débit, de la pression et de la concentration d’oxygène . . . . . . . . . . . . . . . . . . . . . 4.2 Passage d’une unité de mesure de pression à une autré. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.3 Procédure de contrôle de la calibration . . . . . . . . . . 4.4 Facteurs influençant l'obtention de résultats exacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Effets de la température . . . . . . . . . . . . . . . . . . . . . . Effets de l’humidité . . . . . . . . . . . . . . . . . . . . . . . . . Autres gaz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Effets d’un débit faible . . . . . . . . . . . . . . . . . . . . . . . 5 21 21 21 22 22 22 26 26 26 26 26 26 27 27 27 Codes d'erreur . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 5.1 Codes d’erreur . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 1 Généralités 1.1 Symboles Les mots de signalisation servent à indiquer des dangers ou pratiques dangereuses pouvant résulter en des blessures ou des dommages matériels. Voir les informations ci-dessous pour la définition des mots de signalisation. 1.2 Utilisation conforme AVERTISSEMENT ! – Le Check O2 Plus sert à contrôler les concentrateurs d’oxygène seulement. – NE PAS utiliser le Check O2 Plus pour la surveillance continue de l’oxygène. Le Check O2 Plus ne doit être utilisé que par du personnel qualifié. DANGER ! – Danger indique une situation dangereuse imminente qui, si elle n'est pas évitée, peut entraîner de graves blessures. AVERTISSEMENT ! – Avertissement indique une situation potentiellement dangereuse si elle n’est pas évitée et peut résulter dans la mort ou des blessures graves. ATTENTION ! – Attention indique une situation potentiellement risquée qui, si elle n'est pas évitée, peut entraîner des dégâts personnels ou des lésions mineures. Conseils, recommandations et informations utiles pour une utilisation efficace et sans soucis. L´analyseur d´oxygène Check O2 Plus mesure le débit et la concentration d´oxygène en utilisant la technologie ultrasonique, ainsi que la pression de l´oxygène en utilisant un capteur de pression en silicum piézorésistif. L’analyseur d’oxygène Check O2 Plus est un outil utilisé pour mesurer la pureté, le débit et la pression de l’oxygène d’un concentrateur d’oxygène. L’analyseur d’oxygène Check O2 Plus n’est pas conçu pour être utilisé par les patients auxquels il a été prescrit de l’oxygène. De même, il n’est pas conçu pour la surveillance continue ou la confirmation d’alimentation en oxygène d’un patient. L’analyseur d’oxygène Check O2 Plus est conçu pour être utilisé dans un environnement où les concentrateurs d’oxygène sont entretenus ou réparés. Ces lieux comprennent les hôpitaux, les maisons de retraite, les établissements de soins prolongés, le domicile des patients et les centres de réparation et d’entretien des appareils respiratoires. Ce produit est conforme à la Directive 93/42/CEE sur les dispositifs médicaux. La date de lancement de ce produit est indiquée dans la déclaration de conformité CE. 20 1176119-A Aperçu du système 2 Aperçu du système 2.2 Identification des composantes 2.1 Description et Principe de fonctionnement Le Check O2 Plus est un analyseur d’oxygène conçu pour vérifier le débit, la pression de sortie et la concentration d’oxygène des concentrateurs d’oxygène. Le Check O2 Plus offre des performances et une fiabilité inégalées grâce à sa conception de pointe qui inclut les fonctionnalités et les avantages opérationnels suivants : • • • • • • • • • • • Une mesure précise du taux d’oxygène. Le calibrage par l´utilisateur n´est pas requis. La possibilité de mesurer la pression en PSI ou en kPa. Une conception durable et compacte. Un affichage à cristaux liquides (ACL) de grande taille et facile à lire. Un port d’entrée des échantillons de gaz blindé et renforcé. Une longue durée d’utilisation avec 2 piles AA. Un arrêt automatique après 4 minutes. Une indication de pile faible. Les auto-diagnostics. Un nettoyage facile. 1176119-A A Écran à cristaux liquide D Entrée de l’échantillon de gaz B Bouton de mode E Sortie de l’échantillon de gaz C Bouton de marche/arrêt F Couvercle du compartiment des piles 21 2.3 Guide des symboles Les étiquettes de sécurité et les symboles suivants figurent sur le Check O2 Plus: Représentant autorisé dans la communauté européenne Ne pas jeter. Suivre les directives locales pour l’élimination Évalué par ETL (Intertek Testing Laboratories) Fabricant Indice de protection Sans latex Numéro de série Numéro de catalogue Veuillez consulter les documents d’accompagnement Bouton de marche/arrêt — Éteint ou allume l’appareil. Bouton de marche/arrêt Bouton de mode — Bascule entre la mesure de la concentration de gaz produit par un concentrateur d’oxygène et de l’oxygène pur (pour vérifier la calibration). Bouton de mode Indicateur de pile faible — Indique que la tension des piles est en dessous des niveaux de fonctionnement normal. Pile faible LPM — Illuminé à côté de la mesure de débit. (Non illustré en mode de vérification de la calibration.) Débit en litre par minute Livres par pouce carré Kilopascals Pourcentage Entrée de l’échantillon de gaz Sortie de l’échantillon de gaz Courant continu 2.4 Description des composantes 3 1/2 chiffres à l’écran — L’écran à cristaux liquide permet une lecture directe de la concentration d’oxygène, du débit et de la 22 pression du gaz. L’écran à cristaux liquide affiche également les codes d’erreur si nécessaire. kPA — Indique que la mesure de la pression est exprimée en kilopascals. PSI — Indique que la mesure de la pression est exprimée en livres par pouce carré. Symbole « % » — Illuminé à côté de la mesure de la concentration. Entrée de l’échantillon de gaz — Utilisée pour recevoir l’échantillon de gaz. Sortie de l’échantillon de gaz — Utilisée comme sortie pour l’échantillon de gaz et comme un déclencheur pour la mesure de la pression lors d’une obstruction. Tubulure de l’échantillon de gaz — Permet de connecter les sources d’échantillon de gaz. 2.5 L’emballage comprend • Manuel d’utilisation • Tubulure de l’échantillon de gaz • Couvercle souple 1176119-A Sécurité 3 Sécurité 3.1 Mises en garde AVERTISSEMENT ! – Ce chapitre contient des informations importantes concernant le fonctionnement et lʹutilisation sans danger de ce produit. – NE PAS UTILISER CE PRODUIT ou tout autre produit optionnel sans avoir au préalable lu et compris ces instructions complémentaires comme les manuels d'utilisation, les manuels de maintenance et la notice d'instruction avec le produit ou tout équipement optionnel. EN CAS D'INCOMPREHENSION DES MISES EN GARDE, DES MESSAGES D'AVERTISSEMENT ou DES INSTRUCTIONS, veuillez contacter un professionnel de santé, votre distributeur ou le personnel technique avant de tenter d'utiliser cet appareil - le cas échéant, IL Y A UN RISQUE DE BLESSURE CORPORELLE ou de DOMMAGE MATERIEL. AVERTISSEMENT SUR LES ACCESSOIRES – Les produits Invacare sont conçus et fabriqués spécialement pour une utilisation en combinaison avec les accessoires Invacare. Les accessoires conçus par d’autres fabricants n’ont pas été testés pour une utilisation par Invacare et ne sont donc pas recommandés pour une utilisation avec les produits Invacare. 1176119-A DANGER ! Pour réduire le risque de brûlures, d’electrocution, d’incendie ou de dommages corporels – Ne l’utilisez pas dans les applications d’anesthésie ou pour mesurer des concentrations d’oxygène à partir de toutes autres sources que les concentrateurs d’oxygène conventionnels. – Ne l’utilisez pas avec des agents d’inhalation. Utiliser le Check O2 Plus dans des environnements inflammables ou explosifs peut entraîner un incendie ou une explosion. – Ne pas utiliser en présence de mélanges d’anesthésiques inflammables. – L'oxygène est un comburant et accélère rapidement la combustion. NE FAS FUMER en utilisant le Check O2 Plus pendant la vérification de l'appareil. – Ne pas utiliser dans un environnement d’IRM. 23 AVERTISSEMENT ! Une utilisation incorrecte du Check O2 Plus peut causer des mesures d’oxygène inexactes qui pourraient conduire à un traitement inadéquat ou à des conséquences néfastes pour le patient. Suivez les procédures décrites dans ce manuel. – Les utilisateurs doivent bien se familiariser avec les informations contenues dans ce Manuel de fonctionnement avant de procéder. Le strict respect du mode d’emploi est nécessaire pour assurer la sécurité et l’efficacité du produit. Ce produit fonctionne comme prévu uniquement lorsqu’il est utilisé conformément au mode d’emploi du fabricant. – NE PAS utiliser le ’Check O2 Plus pour mesurer la concentration d’oxygène d’un concentrateur d’oxygène lorsque le débit est inférieur par rapport à la performance optimale comme spécifié par le fabricant du concentrateur (généralement 4 l/min ou moins sur les concentrateurs qui ont un débit maximum de 10 l/min et 1 l/min ou moins pour les concentrateurs ayant un débit maximum de 5 l/min). – L’utilisation du l’Check O2 Plus près de dispositifs qui génèrent des champs électriques pourrait causer des lectures irrégulières. 24 AVERTISSEMENT ! – Si le Check O2 Plus est exposé à des liquides provenant de déversements ou d’une immersion, retirez immédiatement les piles et laissez l’appareil sécher complètement. Une fois sec, replacez les piles à l’intérieur et vérifiez son bon fonctionnement. – Ne PAS mettre l’appareil dans l’autoclave; ne soumettez PAS non plus le Check O2 Plus à des températures élevées (> 60 °C [140° F]). – Ne recourez PAS à la stérilisation à l’oxyde d’éthylène. – NE PAS exposer le Check O2 Plus aux radiations, au vide, à la vapeur ou à des produits chimiques durs. – N’exposez PAS le Check O2 Plus à une pression supérieure à 344 kPa. L´exposition à une pression supérieure à 344 Kpa pourrait causer des fuites dans le dispositif cequi peut affecter négativement les performances au niveau du débit et de la pression d´oxygène. – La réparation ou la modification du l’Check O2 Plus par une personne autre qu’un représentant du service autorisé par Maxtec pourrait faire en sorte que le produit ne fonctionne pas comme prévu. 1176119-A Sécurité ATTENTION ! – Remplacez les piles par des piles AA alcalines ou au lithium de haute qualité. Ne PAS utiliser PAS de piles rechargeables. – Lorsque l’appareil n’est pas utilisé pendant des périodes de plus de 30 jours, enlevez les piles pour protéger le Check O2 Plus d’une fuite potentielle. – Évitez de laisser tomber le Check O2 Plus pour prévenir des dommages qui pourraient affecter ses performances. Si vous suspectez que l´appareil ait subi des dommages, effectuez 4.3 Procédure de contrôle de la calibration , page 26. – Éviter l’entrée de matières étrangères dans le Check O2 Plus. – NE PAS utiliser le Check O2 Plus pour vérifier un concentrateur avec un humidificateur en place. L’humidité d’un humidificateur peut endommager l’appareil. – NE PAS vérifier un concentrateur en appuyant sur le bouton « MODE » sinon la lecture sera inexacte. – À la suite d’un stockage dans des conditions extrêmement chaudes ou froides, laisser un passage de débit de gaz suffisant pour que les capteurs internes atteignent la température du gaz ou attendre que la température de l’analyseur s’équilibre avec la température ambiante avant l’utilisation. 1176119-A 3.2 Elimination Ce produit a été livré par un fabricant soucieux de lʹenvironnement et conforme à la directive 2002/96/CE sur la mise au rebut des équipements électroniques et électriques WEEE. Ce produit est susceptible de contenir des substances potentiellement nocives pour l’environnement s’il est mis au rebut dans des endroits (décharges) non conformes à la législation en vigueur. Merci de préserver l’environnement et de recycler ce produit en fin de vie auprès de votre station de recyclage locale. L’élimination avec les déchets ordinaires n’est pas appropriée pour les piles et le circuit électronique. 25 4 Mode d'emploi 4.1 Mesure du débit, de la pression et de la concentration d’oxygène Pour vérifier le débit, la pression et la concentration en oxygène d’un échantillon de gaz provenant d’un concentrateur : 1. 2. 3. 4. 5. 6. 7. Connectez la tubulure de l’échantillon de gaz à l’entrée de l’échantillon de gaz du Check O2 Plus. Branchez l’autre extrémité de la tubulure de l’échantillon de gaz au concentrateur d’oxygène. Initiez le flux de gaz vers le Check O2 Plus à un débit de 1 à 10 litres par minute (un débit de 2 litres par minute est recommandé). Assurez-vous que le débit du concentrateur soit stable selon les recommandations du fabricant du concentrateur. Allumez le Check O2 Plus. Laissez la mesure se stabiliser pendant environ 10 secondes avant de lire le débit et la concentration en oxygène. Pour vérifier la pression, couvrez la prise d’échantillon de gaz avec le pouce ou un doigt pendant que le gaz s’écoule. Attendez 5 secondes pour que l’affichage affiche la pression. NE PAS appuyer sur le bouton « MODE » pendant la vérification d’un concentrateur sinon la lecture sera inexacte. 4.2 Passage d’une unité de mesure de pression à une autré Le Check O2 Plus peut mesurer la pression en PSI ou kPa. Le Check O2 Plus est réglé en usine pour mesurer en PSI. Pour basculer en kPa : 26 1. 2. 3. À l’aide d’un tournevis cruciforme nº 1, dévissez la vis du compartiment des piles et retirez le couvercle. Poussez l’interrupteur à l’intérieur du compartiment des piles. Remettez le couvercle du compartiment des piles et serrez la vis. 4.3 Procédure de contrôle de la calibration Le mode de vérification de la calibration est prévu pour vérifier que le Check O2 Plus fonctionne correctement. Pour effectuer le contrôle de la calibration : 1. 2. 3. 4. Allumez le Check O2 Plus. Connectez une source d’oxygène pur (≥ 99,95 %) à l’entrée de l’échantillon de gaz. Réglez le débit du gaz vers le Check O2 Plus entre 2 et 5 LPM. Assurez-vous que le gaz qui circule dans le Check O2 Plus est à une température stable. Appuyez sur le bouton de mode et maintenez-le enfoncé. La concentration devrait se situer entre 98,5 % et 101,5 % d’oxygène. Si la mesure de concentration ne se situe pas dans cette fourchette, appelez le service à la clientèle. Le mode de contrôle de la calibration est indiqué par les lettres « CAL » et « VER » qui clignotent à l’écran sous la mesure. 4.4 Facteurs influençant l'obtention de résultats exacts Effets de la température Le Check O2 Plus’ adapte aux changements de température et fonctionnera selon les spécifications sur toute la plage de températures de fonctionnement. Toutefois, la prise de mesures au cours de changements rapides de la température des gaz doit être évitée. 1176119-A Mode d'emploi Effets de l’humidité Effets d’un débit faible Le Check O2 Plus dispose d’un capteur d’humidité pour mesurer l’humidité des gaz entrant dans le dispositif et s’ajuster en conséquence. Toutefois, des niveaux élevés d’humidité (condensation) peuvent affecter la précision et la fiabilité du Check O2 Plus. Pour éviter tout dommage possible : Les concentrateurs d´oxygène fonctionnent en enlevant le nitrogène de l´air et en ne laissant que l´oxygène et l´argon dans une proportion bien déterminée. Ce principe de fonctionnement peut être altéré quand les concentrateurs sont utilisés dans des conditions où les débits ne correspondent pas au minimum recommandé par le fabricant. A faibles débits, ils peuvent afficher de faibles concentrations en oxygène ex. 85% à 91%, pas nécessairement à cause d´une forte concentration en nitrogène, mais plutôt à cause d´une augmentation de la concentration en argon. Le ratio oxygène/ argon doit absolument rester constant afin que le Check O2 Plus puisse garantir une fiabilité et une exactitude des résultats de +/1.5% d´oxygène. • Évitez l’utilisation dans des environnements contenant une humidité relative de plus de 95 %. • N’utilisez PAS cet appareil dans un circuit respiratoire. • Ne respirez ou ne soufflez PAS dans le Check O2 Plus. Autres gaz Le Check O2 Plus est conçu pour mesurer deux types de mélanges de gaz : • Un mélange d’oxygène, d’azote et d’argon provenant des concentrateurs d’oxygène. • De l’oxygène pur pendant le mode de contrôle de la calibration. Toutes autres concentrations ou combinaisons de gaz auront pour conséquence que le Check O2 Plus mesurera la concentration en oxygène de manière incorrecte. 1176119-A • Ne pas utiliser le Check O2 Plus pour mesurer la concentration en oxygène d´un concentrateur quand les débits ne correspondent pas à ceux requis par le fabricant. En général, ne pas mesurer la concentration eu oxygéne á moins de 4 LPM lorsque le débit maximum atteint les 10 LPM. Ne pas mesurer la concentration á moins de 1 LPM pour un débit maximum de 5LPM. 27 5 Codes d'erreur 5.1 Codes d’erreur Le Check O2 Plus contient une fonction d’auto-diagnostic intégrée dans le logiciel pour détecter les lectures erronées en dehors des plages de fonctionnement normales. Les codes, les descriptions et les actions recommandées sont : • E01: la mesure de l’oxygène est supérieure à la limite (≥ 102,0 • • • • 28 %, calculée par algorithme). Action recommandée : vérifiez que le Check O2 Plus soit utilisé dans le bon mode (concentrateur ou mode de contrôle de la calibration). Si le code d’erreur se répète, effectuez un contrôle de la calibration selon la section 4.3 de ce manuel. Si le code d’erreur se répète à nouveau, contactez le service clients. E02: la mesure de l’oxygène est inférieure à la limite (≤ -2,0 %, calculée par algorithme). Action recommandée : vérifiez que le Check O2 Plus soit utilisé dans le bon mode (concentrateur ou mode de vérification de la calibration). Si le code d’erreur se répète, effectuez un contrôle de la calibration selon la section 4.3 de ce manuel. Si le code d’erreur se répète à nouveau, contactez le service clients. E03: la mémoire de l’appareil est endommagée ou manquante. Action recommandée : renvoyer le Check O2 Plus au fabricant pour une réparation en usine. E04: la lecture du signal n’est pas stable. Action recommandée : renvoyer le Check O2 Plus au fabricant pour une réparation en usine. E05: mesure de la pression hors limite (≥ 50 PSI). Action recommandée : vérifiez la pression d’une source de gaz dont la pression est connue. Si le code d’erreur se répète, contactez le service clients. • E06: température de fonctionnement trop élevée (≥ 40 °C). Action recommandée : le Check O2 Plus est trop chaud, laissez l’appareil se refroidir jusqu’à ce qu’il s’approche de la température ambiante avant utilisation. • E07: température de fonctionnement trop basse (≤ 15 °C). Action recommandée : le Check O2 Plus est trop froid, réchauffez l’appareil jusqu’à ce qu’il se rapproche de la température ambiante avant utilisation. • E08: l’auto-contrôle de l’appareil a trouvé une erreur. Action recommandée : retirez et remplacez les piles. Si le code d’erreur se répète, retournez le Check O2 Plus au fabricant pour une réparation en usine. 1176119-A Remplacement des piles 6 Remplacement des piles 6.1 Procédure de remplacement des piles Les piles doivent être remplacées lorsque l’icône e la pile s’allume. L’icône de la pile restera allumée jusqu’à ce que les piles soient changées. Si le niveau des piles est trop faible, le Check O2 Plus ne s’allumera pas jusqu’à ce que les piles soient changées. 1. 2. 3. 4. 5. À l’aide d’un tournevis cruciforme nº 1, dévissez la vis A du compartiment des piles et retirez le couvercle B. Retirez les piles. Insérez des piles neuves et assurez-vous qu’elles sont correctement placées. Ne PAS ’utiliser de piles rechargeables. Remettez le couvercle du compartiment des piles et serrez la vis. Si le Check O2 Plus ne s’allume pas lorsque vous avez terminé, vérifiez que les piles soient installées correctement et qu’elles soient neuves. 1176119-A 29 7 Nettoyage et entretien 7.1 Nettoyage ATTENTION ! Risque d’endommagement du produit. Faites attention pour éviter la pénétration de tout liquide dans le Check O2 Plus. – Ne pas tremper ou ne PAS immerger le Check O2 Plus dans du liquide. – Ne PAS mettre le appareil à l’autoclave; ne soumettez PAS non plus l’Check O2 Plus à la stérilisation à l’oxyde d’éthylène. 7.2 Entretien • Remplacez les piles par des piles AA alcalines ou au lithium de haute qualité. Ne PAS utiliser de piles rechargeables. • Lorsque l’appareil n’est pas utilisé pendant plus de 30 jours, enlevez les piles pour protéger le Check O2 Plus d’une fuite potentielle. • Conservez le Check O2 Plus entre -15 °C et 60 °C (5 °F et 140 °F). Essuyez les surfaces extérieures du Check O2 Plus avec un chiffon humide imbibé de savon pour les mains ou de liquide vaisselle doux (pH 6-8). 30 1176119-A Caractéristiques techniques 8 Caractéristiques techniques 8.1 Paramètres Caractéristiques Du Produit OXYGÈNE Plage de mesure de l’oxygène : (À partir d’un concentrateur) : Exactitude de la mesure d’oxygène : Résolution de la mesure d’oxygène : 20,9 à 96 % ± 1,5 % du volume total à température constante * 0,1 % d’oxygène *See Effets d’un débit faible, page 27 of this operating manual for information on the effects of low flow. FLUX Plage de mesure du débit : Exactitude de la mesure du débit : Précision de la mesure du débit : PRESSION Plage de mesure de la pression : Précision de la mesure de la pression : Résolution de la mesure de la pression : Temps de réponse : 1176119-A 0 à 10 LPM ± 0,2 LPM 0,1 LPM PSI 0,5 à 50 kPa 3,4 à 344 ±0,5 % ±0,5 % 0,1 0,1 jusqu’à 199, 1 de 200 à 344 Temps de préchauffage : Température de fonctionnement : Température d’entreposage : Pression barométrique : Humidité : Alimentation électrique : Autonomie de la pile : Indicateur de pile faible : Dimensions : < 1 secondes 15 °C à 40 °C (59 °F à 104 °F) -15 °C à 60 °C (5 °F à 140 °F) 800 à 1000 mbar 0 à 95 % (sans condensation) 2 piles alcalines AA (2 x 1,5 V) ≥1,100 heures (16,500 cycles de lecture) Une icône « Pile Faible » s’affiche à l’écran 3,39 po x 5,10 po x 1,00 po [86,1 mm x 125,5 mm x 25,4 mm] 0,4 lb (181 g) Poids : CLASSIFICATIONS Protection contre les Équipement électrique à source d’énergie décharges électriques interne : Protection contre l’eau : Mode de Continu fonctionnement : Stérilisation : Voir 7.1 Nettoyage, page 30. Mélanges Ne pas utiliser en présence de mélanges d’anesthésiques d’anesthésiques inflammables inflammables : Spécifications de 1,8 à 3,2 V 32 mW 10 mA puissance : ≤ 17 secondes 31 9 Garantie 9.1 Garantie limitée – Amérique du Nord Cette garantie couvre uniquement l’acheteur/utilisateur d’origine de nos produits. Cette garantie vous donne des droits spéciaux et vous pouvez également jouir d’autres droits variant d’un état à l’autre. Invacare garantit à l’acheteur d’origine que ce produit est exempt de défauts affectant les matériaux et la fabrication, et ce, pendant trois ans (hors pneus et roues). Si, durant cette période de garantie, le produit devait s’avérer défectueux, il serait remplacé ou réparé, à l’appréciation d’Invacare. Cette garantit n’inclut pas les frais de main-d’oeuvre ou de transport encourus dans l’installation de la pièce de rechange ou la réparation du produit. La seule obligation d’Invacare et votre recours exclusif sous cette garantie sont limités aux réparations et/ou remplacements. Pour le service sous garantie, veuillez contacter le revendeur qui vous a vendu votre produit Invacare. Dans le cas où le service de garantie ne vous donnerait pas satisfaction, veuillez écrire directement à Invacare à l’adresse au verso. Indiquez le nom du revendeur, l’adresse, le numéro du modèle, la date d’achat, la nature du défaut et, si le produit en porte un, le numéro de série. Invacare Corporation émettra une autorisation de retour. L’appareil défectueux ou les pièces défectueuses doivent être retournés pour une inspection sous garantie avec le numéro de série, si applicable, en tant qu’identifiant dans les trente (30) jours suivant la date d’autorisation de retour. NE PAS retourner les produits à notre usine sans notre accord préalable. Les envois contre remboursement seront refusés. Merci de régler les frais de transport. LIMITATIONS ET EXCLUSIONS : LA GARANTIE NE S’APPLIQUE PAS AUX PROBLEMES PROVENANT D’UNE USURE NORMALE OU DU NONRESPECT DES INSTRUCTIONS CI-JOINTES. EN OUTRE, LA PRESENTE GARANTIE NE S’APPLIQUE PAS AUX 32 PRODUITS PORTANT UN NUMERO DE SERIE SI LE NUMERO DE SERIE A ETE EFFACE OU SUPPRIME ; AUX PRODUITS SOUMIS A LA NEGLIGENCE, A UN ACCIDENT, A UNE UTILISATION, UNE MAINTENANCE OU UN ENTREPOSAGE NON-CONFORMES ; OU AUX PRODUITS AYANT SUBI DES MODIFICATIONS SANS LE CONSENTEMENT PREALABLE ECRIT D’INVACARE, INCLUANT MAIS NON LIMITEES A : MODIFICATION PAR L’UTILISATION DE PIECES OU ACCESSOIRES NON AUTORISES : LES PRODUITS ENDOMMAGES EN RAISON DE REPARATIONS FAITES SUR UN COMPOSANT SANS LE CONSENTEMENT D’INVACARE ; LES PRODUITS ENDOMMAGES PAR DES CIRCONSTANCES AU-DELA DU CONTROLE D’INVACARE ; LES PRODUITS REPARES PAR TOUT AUTRE QU’UN REVENDEUR INVACARE, L’EVALUATION EST LAISSEE A L’APPRECIATION D’INVACARE. LA PRESENTE GARANTIE EXPRESSE EST EXCLUSIVE ET REMPLACE TOUTE AUTRE GARANTIE, EXPRESSE OU IMPLIQUEE, Y COMPRIS LES GARANTIES IMPLIQUEES DE QUALITE MARCHANDE ET CONFORMITE A UNE UTILISATION PARTICULIERE, ET LE SEUL RECOURS EN CAS DE VIOLATIONS DE TOUTE GARANTIE QUI SOIT EST LIMITEE AUX REPARATIONS OU REMPLACEMENTS DU PRODUIT DEFECTUEUX PROCEDANT DES PRESENTES CONDITIONS. L’APPLICATION DE TOUTE GARANTIE IMPLIQUEE NE S’ETEND PAS AU-DELA DE LA DUREE DE LA GARANTIE EXPRESSE FOURNIE ICI. INVACARE NE SAURAIT ÊTRE TENU RESPONSABLE DE QUELQUE DOMMAGE CONSÉQUENT OU FORTUIT. CETTE GARANTIE SERA ETENDUE POUR SE CONFORMER AUX EXIGENCES LEGALES DE L’ETAT/DE LA PROVINCE. 1176119-A Garantie 9.2 Garantie Invacare® garantit l'absence de défauts et le bon fonctionnement de votre produit. La garantie s'étend à tous les défauts et anomalies qui sont démontrés être dus à une construction défectueuse, à un mauvais matériau ou à une conception erronée. Seul le distributeur agréé et non l’utilisateur du produit, peut faire valoir des droits de garantie vis-à-vis de Invacare®. Ne font pas partie de la garantie l'usure normale, les suites d'un maniement non conforme ou d'une détérioration, un mauvais entretien, un montage ou une mise en service incorrect(e) du fait de l'acheteur ou de tiers, ainsi que les défauts dus à des circonstances extérieures. L'obligation de garantie expire si des modifications non prévues ou non réalisées par le revendeur spécialisé sont apportées au produit ou en cas d'utilisation de pièces de rechange non conformes. La garantie de Invacare® ne comprend pas les frais consécutifs à l'élimination des défauts, tels que les frais de transport et de déplacement, les coûts salariaux, les charges, etc. Le délai de garantie est de 24 mois. Les pièces d'usure sont exclues de la garantie. Par ailleurs, les termes de la garantie sont propres aux conditions de ventes de chaque pays dans lequel le produit est vendu. 1176119-A 33 Notes 6.1 Contenido Este manual debe ser entregado al usuario final. de usar este producto lea este manual y guárdelo para futuras referencias. 1 Generalidades . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 1.1 Símbolos . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 1.2 Uso previsto . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 2 Resumen sobre el sistema . . . . . . . . . . . . . . . . . . . . . . . 2.1 Descripción y principio de funcionamiento . . . . . . . . 2.2 Identificación de componente . . . . . . . . . . . . . . . . . 2.3 Guía de símbolos . . . . . . . . . . . . . . . . . . . . . . . . . . 2.4 Descripción de componente . . . . . . . . . . . . . . . . . . 2.5 Se incluye con su unidad . . . . . . . . . . . . . . . . . . . . . 3 Seguridad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 3.1 Instrucciones Generales . . . . . . . . . . . . . . . . . . . . . . 39 3.2 Eliminación . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 4 Instruciones de operación . . . . . . . . . . . . . . . . . . . . . . . 4.1 Medición de flujo y presión de oxígeno . . . . . . . . . . . 4.2 Cómo cambiar unidades de medición de presión ....................................... 4.3 Procedimiento de verificación de calibración . . . . . . . 4.4 Factores que influyen en una lectura precisa. . . . . . . . Efectos de la temperatura . . . . . . . . . . . . . . . . . . . . Efectos de la humedad . . . . . . . . . . . . . . . . . . . . . . . Efectos de otros gases . . . . . . . . . . . . . . . . . . . . . . . Efectos de bajo flujo . . . . . . . . . . . . . . . . . . . . . . . . . 37 37 37 38 38 38 42 42 42 42 42 42 43 43 43 5 Códigos de error. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 5.1 Códigos de Error . . . . . . . . . . . . . . . . . . . . . . . . . . 44 6 Cómo cambiar las baterías . . . . . . . . . . . . . . . . . . . . . . 45 Procedimiento de sustitución de baterías . . . . . . . . . 45 7 Limpieza y mantenimiento . . . . . . . . . . . . . . . . . . . . . . 46 7.1 Limpieza . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 7.2 Mantenimiento . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 8 Datos técnicos. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 8.1 Parámetros Habituales del Producto . . . . . . . . . . . . . 47 9 Garantía . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 9.1 Garantía limitada - Norteamérica . . . . . . . . . . . . . . . 48 9.2 Garantía . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 1 Generalidades 1.1 Símbolos En este manual se utilizan símbolos que hacen referencia a peligros o usos poco seguros que pueden provocar lesiones o daños a la propiedad. A continuación se muestran las descripciones de estos símbolos. 1.2 Uso previsto ¡ADVERTENCIA! – El Check O2 Plus está destinado solamente para la comprobación de concentradores de oxígeno. – NO use el Check O2 Plus para el monitoreo continuo de oxígeno. El Check O2 Plus solo debe ser utilizado por personal capacitado. ¡PELIGRO! – Peligro indica una situación inminente y peligrosa que, si no se evita, provocará la muerte o lesiones serias. ¡ADVERTENCIA! – Indica una situación potencialmente peligrosa que si no se evita puede tener como consecuencia la muerte o lesiones graves. ¡PRECAUCIÓN! – Precaución indica una situación de riesgo potencial que, si no se evita, puede provocar daños en la propiedad o lesiones leves o ambas. Proporciona consejos útiles, recomendaciones e información para un uso eficiente y sin problemas. El analizador de oxígeno Check O2 Plus mide la concentración y el flujo de oxígeno mediante una tecnología de ultrasonido y mide la presión mediante un sensor de presión. El analizador de oxígeno Check O2 Plus es una herramienta que se utiliza para medir la pureza, el flujo y la presión de un concentrador de oxígeno. El Check O2 Plus no está destinado a ser utilizado por pacientes a quienes se les prescriba oxígeno, ni está destinado para monitorear o confirmar de forma continua la entrega de oxígeno a un paciente. El analizador de oxígeno esta destinado para utilizarse en entornos en donde se esté dando mantenimiento o reparando concentradores de oxígeno. Esto incluye hospitales, residencias para ancianos, instalaciones de atención extendida, residencias para pacientes y centros de reparación y mantenimiento de dispositivos de respiración. Este producto cumple con la Directiva 93/42/EEC en lo concerniente a dispositivos médicos. La fecha de lanzamiento de este producto figura en la declaración de conformidad CE. 36 1176119-A Resumen sobre el sistema 2 Resumen sobre el sistema 2.2 Identificación de componente 2.1 Descripción y principio de funcionamiento El Check O2 Plus es un analizador de oxígeno diseñado para comprobar la concentración de oxígeno, el flujo y la presión de salida de concentradores de oxígeno. El Check O2 Plus ofrece un rendimiento sin paralelos gracias a su avanzado diseño, e incluye las siguientes ventajas funcionales y operacionales: • Mediciones precisas de oxígeno • No se requiere de calibración en campo. • Capacidad para medir presión en PSI o kPa, lo cual resulta muy • • • • • • • • práctico. Diseño compacto y duradero Pantalla de cristal líquido (LCD) grande y fácil de leer Puerto de entrada de gas blindado y reforzado Baterías AA con larga vida útil Apagado automático después de 4 minutos. Indicación de batería baja Auto diagnóstico Fácil de limpiar 1176119-A A La pantalla LCD D Entrada de muestra de gas B Botón de modo E Salida de muestra de gas C Botón ON/OFF F Compartimento de baterías 37 2.3 Guía de símbolos Botón ON/OFF - Apaga y enciende el equipo. El Check O2 Plus posee los siguientes símbolos y letreros de seguridad: Botón de modo - Cambia entre la medición de concentración de gas producido por un concentrador de oxígeno y la medición de oxígeno puro (para la verificación de calibración). Representante autorizado en la Comunidad Europa No tirar. Para desechar la unidad siga las directrices locales. Evaluado por ETL (Laboratorios de comprobación Intertek) Fabricante Botón on/off Protección contra ingreso No contiene látex Libras por pulgada cuadrada Kilopascales Número de serie Número de catálogo Por ciento Entrada de muestra de gas Salida de muestra de gas Salida de muestra de gas – Se utiliza como salida de la muestra de gas y cuando se cierra actúa como disparador de la medición de presión. Corriente continua 2.5 Se incluye con su unidad Consulte la documentación adjunta Botón de mover Batería baja LPM – Se ilumina al lado de la indicación de medición de flujo. (no se muestra cuando en el modo de verificación de calibración). KPA – Indica que la medición de la presión se da en unidades de kilopascales. PSI – Indica que la medición de la presión se da en unidades de libras por pulgada cuadrada. Litros por minuto 2.4 Descripción de componente Pantalla digital 3 1/2 - La pantalla LCD ofrece lecturas directas de concentración de oxígeno, flujo de gas y presión de gas. La pantalla LCD también muestra los códigos de error según corresponda. 38 Indicador de batería baja – Indica que la tensión en volteos de las baterías está por debajo de los niveles normales de funcionamiento. Símbolo "%" – Se ilumina al lado de la indicación de medición de concentración. Entrada de muestra de gas – Se utiliza para recibir la muestra de gas. Tubo de muestra de gas – Se utiliza para conectar el equipo a las fuentes de muestra de gas. • Manual del usuario • Tubería para muestra de gas • Tapa suave 1176119-A Seguridad 3 Seguridad 3.1 Instrucciones Generales ¡ADVERTENCIA! – Esta sección contiene información importante para el funcionamiento y uso seguro de este producto – NO UTILICE ESTE PRODUCTO NI CUALQUIER OTRO EQUIPO OPCIONAL DISPONIBLE SIN ANTES HABER LEÍDO Y COMPRENDIDO ESTAS INSTRUCCIONES Y CUALQUIER OTRO MATERIAL INFORMATIVO ADICIONAL, COMO MANUALES DEL USUARIO, MANUALES DE SERVICIO U HOJAS DE INSTRUCCIONES PROPORCIONADOS CON ESTE PRODUCTO O EQUIPO OPCIONAL. SI TIENE ALGUNA DUDA RELACIONADA CON LAS ADVERTENCIAS, PRECAUCIONES O INSTRUCCIONES, PÓNGASE EN CONTACTO CON UN PROFESIONAL SANITARIO, SU REPRESENTANTE O UN TÉCNICO ANTES DE INTENTAR UTILIZAR ESTE EQUIPO. DE LO CONTRARIO, EXISTE EL RIESGO DE PRODUCIRSE LESIONES O DAÑOS. ADVERTENCIA DE LOS ACCESORIOS – Los productos Invacare están específicamente diseñados y fabricados para usarse conjuntamente con los accesorios Invacare. Invacare no ha probado los accesorios diseñados por otros fabricantes y, por consiguiente, no están recomendados para usarse con los productos Invacare. 1176119-A ¡PELIGRO! PARA REDUCIR EL RIESGO DE QUEMADURAS, ELECTROCUCIÓN, INCENDIO O LESIONES A PERSONAS – No debe utilizarse en aplicaciones con anestesia o para medir concentraciones de oxígeno provenientes de fuentes que no sean los concentradores de oxígeno convencionales. – No debe utilizarse agentes de inhalación. Hacer funcionar el Check O2 Plus en entornos explosivos o inflamables puede provocar incendios o explosiones. – No adecuado para utilizarse en presencia de mezclas anestésicas inflamables. – El oxígeno acelera rápidamente la combustión. No fume cuando esté utilizando el Check O2 Plus para comprobar concentradores de oxígeno. – No se debe usar en entornos de resonancia magnética. 39 ¡ADVERTENCIA! El uso inadecuado del Check O2 Plus puede provocar lecturas de oxígeno imprecisas, lo cual puede conllevar a la indicación de tratamientos inadecuados y/o causar daños al paciente. Siga los procedimientos que se describen en este manual. – Los usuarios deben conocer bien la información que contiene este manual de operaciones antes del uso del equipo. Para el funcionamiento seguro y efectivo del producto es necesaria la observancia estricta de las instrucciones. Este producto funcionará solo para lo que ha sido diseñado si se opera cumpliendo con las instrucciones de operación proporcionadas por el fabricante. – NO use el Check O2 Plus para medir la concentración de oxígeno de concentradores cuando la velocidad de flujo sea inferior a la de su rendimiento óptimo, especificado por el fabricante, dicha velocidad es generalmente 4 LPM o menos en concentradores con un flujo máximo de 10 LPM, y de 1 LPM o menos en concentradores con un flujo máximo de 5 LPM. – Utilizar el Check O2 Plus cerca de objetos que generan campos eléctricos puede provocar lecturas erróneas. 40 ¡ADVERTENCIA! – Si el Check O2 Plus se expusiera a líquidos derramados o se sumergiera en ellos, quite inmediatamente las baterías y deje que el equipo se seque completamente. Cuando esté seco, sustituya las baterías y compruebe que funciona correctamente. – No esterilice el Check O2 Plus en autoclaves ni lo exponga a altas temperaturas (>60°C [140° F]). – NO lo esterilice con óxido de etileno. – NO exponga el Check O2 Plus a irradiaciones, vacío, vapor o compuestos químicos fuertes. – NO exponga el Check O2 Plus a presiones superiores a los 50 psi. La exposición a presiones por encima de los 50 psi puede causar filtraciones en el dispositivo que pudieran afectar su desempeño en las lecturas de flujo y presión. – La reparación o modificación del Check O2 Plus por cualquier individuo que no sea el agente autorizado de Invacare puede conllevar a que el producto no funcione como se espera. 1176119-A Seguridad ¡PRECAUCIÓN! – Sustituya las baterías por baterías AA de litio o alcalinas de alta calidad. NO use baterías recargables. – Cuando no lo vaya a utilizar por más de 30 días, quite las baterías para proteger el Check O2 Plus contra posibles derrames de las baterías. – Evite dejar caer el Check O2 Plus para protegerlo contra daños que pueden afectar su rendimiento. Si se sospecha que el equipo presenta daños, realice el procedimiento de calibración de verificación que se describe en 4.3 Procedimiento de verificación de calibración , página 42. – Evite que materias extrañas penetren al interior del Check O2 Plus . – NO utilice el Check O2 Plus para comprobar un concentrador que tenga instalado un humidificador. La humedad del humidificador puede dañar el equipo. – NO compruebe un concentrador al tiempo que mantiene presionado el botón de modo, de lo contrario la lectura no será precisa. – Después de haberlo guardado en condiciones de frío o calor extremos, deje que el gas fluya a través del analizador por un tiempo suficiente como para que los sensores internos alcancen la temperatura del flujo de gas o espere a que el analizador se equilibre a temperatura ambiente antes de utilizarlo. 1176119-A 3.2 Eliminación Este producto ha sido suministrado por un fabricante consciente por el medioambiente que cumple con la Normativa de Desechos de Equipos Eléctricos y Electrónicos (WEEE) 2002/96/CE. Este producto puede contener sustancias que pueden ser perjudiciales para el medioambiente si se desecha en lugares (vertederos) que no sean los apropiados según la legislación. Proteja el medio ambiente y recicle este producto a través de la planta de reciclaje más próxima cuando llegue al final de su vida útil. Las baterías y la placa de circuito no deben desecharse con la basura corriente. 41 4 Instruciones de operación 4.1 Medición de flujo y presión de oxígeno 1. 2. Con un destornillador Phillips afloje la compuerta del compartimento de las baterías y quítela. Cambie el conmutador que se encuentra dentro del compartimento de las baterías. Vuelva a poner la compuerta del compartimento de baterías y apriete el tornillo. Para comprobar la concentración de oxígeno y la presión y el flujo de una muestra de gas proveniente de un concentrador : 3. 1. 4.3 Procedimiento de verificación de calibración 2. 3. 4. 5. 6. 7. Conecte la tubería para la muestra de gas a la entrada de muestra de gas del Check O2 Plus. Fije el otro extremo de la tubería para muestra de gas al concentrador de oxígeno. Inicie el flujo de gas hacia el Check O2 Plus a una velocidad de 1 litro a 10 litros por minuto (se recomienda 2 litros por minuto). Asegúrese de que la salida del concentrado sea estable, según las recomendaciones del fabricante. Encienda el Check O2 Plus. Deje que la lectura de oxígeno se estabilice durante aproximadamente 10 segundos antes de completar la lectura de concentración y flujo de oxígeno. Para comprobar la presión, tape la salida de muestra de gas con el dedo mientras el gas esté fluyendo. Espere 5 segundos a que la pantalla muestre la lectura de presión. NO mantenga presionado el botón de modo mientras verifica un concentrador, de lo contrario la lectura no será precisa. 4.2 Cómo cambiar unidades de medición de presión El Check O2 Plus puede medir presión en PSI o kPa. El Check O2 Plus está configurado de fábrica para medir en PSI. Para cambiar a KPa: 42 Para comprobar que el Check O2 Plus está funcionando bien, se incluye el modo de verificación. Para realizar la verificación de calibración: 1. 2. 3. 4. Encienda el Check O2 Plus. Conecte una fuente de oxígeno puro (≥99.95%) a la entrada de muestra de gas. Haga fluir de 2 LPM a 5 LPM de gas por el interior del Check O2 Plus. Asegúrese de que el gas esté fluyendo por el Check O2 Plus a una temperatura estable. Pulse y mantenga la pulsado el botón de modo. Mientras mantiene pulsado el botón de modo, la medición de gas debe dar una lectura de 98.5 % y 101.5% de oxígeno. Si la medición de gas no está dentro de este rango, llame al departamento de servicio al cliente. Calibración el modo de verificación se indica por los letreros "CAL" y "VER" que parpadean en la pantalla debajo de la indicación de medición de gas. 4.4 Factores que influyen en una lectura precisa Efectos de la temperatura El Check O2 Plus realiza una compensación de temperatura y funcionará según las especificaciones en todo el rango de temperatura de funcionamiento. Sin embargo, se debe evitar tomar mediciones durante períodos de cambios bruscos de temperatura. 1176119-A Instruciones de operación Efectos de la humedad Efectos de bajo flujo El Check O2 Plus posee un sensor de humedad para detectar y compensar la humedad del gas que entra en el equipo. No obstante, los altos niveles de humedad (con condensado) pueden afectar la precisión y fiabilidad del Check O2 Plus. Para evitar posibles daños: Los concentradores de oxígeno funcionan según el principio de extracción del nitrógeno del aire, dejando el oxígeno y el argón concentrados a una proporción específica de oxígeno/argón. Este principio de funcionamiento puede alterarse cuando los concentradores están configurados para fluir en el extremo bajo de su rango de funcionamiento. En flujos bajos, esto pueden generar baja concentración de oxígeno en la salida, por ejemplo, de 85% a 91%, por motivos que no son el alto contenido de nitrógeno, posiblemente por un incremento en el contenido de argón. El Check O2 Plus requiere que la proporción de oxígeno y argón permanezca constante para poder garantizar una precisión de +/-1.5% de oxígeno. • Evite utilizar el equipo en entornos donde la humedad relativa supere el 95%. • NO use este equipo integrado a un circuito de respiración. • NO respire ni sople hacia el interior del Check O2 Plus. Efectos de otros gases El Check O2 Plus está diseñado para medir dos tipos diferentes de mezclas de gas: • Oxígeno, nitrógeno y argón provenientes de un concentrador. • Oxígeno puro en el modo de verificación de calibración Cualquier otra concentración o combinación de gases hará que el Check O2 Plus realice mediciones incorrectas de concentración de oxígeno. 1176119-A • NO use el Check O2 Plus para medir concentraciones de oxígeno de un concentrador cuando fluye a velocidades más bajas que la requerida para su funcionamiento óptimo, según lo especifica el fabricante del concentrador; generalmente 4 LPM o menos en concentradores con un flujo máximo de 10 LPM, y 1 LPM o menos en concentradores que poseen un flujo máximo de 5 LPM. 43 5 Códigos de error 5.1 Códigos de Error El Check O2 Plus posee funciones de auto-diagnóstico incorporadas al software para detectar lecturas incorrectas fuera de los rangos de funcionamiento normal. Los códigos, descripciones y acciones recomendadas son: • E01: Medición de oxígeno fuera de rango, Alto (≥102.0% • • • • 44 calculado por algoritmo). Acción que se recomienda: Verificar que el Check O2 Plus esté siendo utilizado en el modo correcto (modo de verificación de concentrador o verificación de calibración). Si el código de error se repite; realice una verificación de calibración según lo descrito en la sección 4.3 de este manual. Si el código de error se repite de nuevo; contacte con el departamento de servicio al cliente. E02: Medición de oxígeno fuera de rango, Bajo (≤-2.0% calculado por algoritmo). Acción que se recomienda: Verificar que el Check O2 Plus esté siendo utilizado en el modo correcto (modo de verificación de concentrador o verificación de calibración). Si el código de error se repite; realice una verificación de calibración según lo descrito en la sección 4.3 de este manual. Si el código de error se repite de nuevo; contacte con el departamento de servicio al cliente. E03: Falta la memoria del dispositivo o está en mal estado. Acción que se recomienda: Contacte con el departamento de servicio al cliente. E04: La señal de lectura no es estable. Acción que se recomienda: Contacte con el departamento de servicio al cliente. E05: Medición de presión fuera de rango, Alto (≥50 PSI). Acción que se recomienda: Compruebe la presión con una fuente de gas conocida. Si si el código de error se repite, contacte con el departamento de servicio al cliente. • E06: Fuera de la temperatura de funcionamiento, Alta (≥40° C). Acción que se recomienda: El Check O2 Plus está demasiado caliente, refresque el equipo llevándolo a una temperatura cercana a la temperatura ambiente antes de utilizarlo. • E07: Fuera de la temperatura de funcionamiento, Baja (≥15° C). Acción que se recomienda: El Check O2 Plus está demasiado frío, caliente el equipo llevándolo a una temperatura cercana a la temperatura ambiente antes de utilizarlo. • E08: Error de auto-comprobación del equipo. Acción que se recomienda: Quite y sustituya las baterías. Si el código de error se repite; Contacte con el departamento de servicio al cliente. 1176119-A Cómo cambiar las baterías 6 Cómo cambiar las baterías 6.1 Procedimiento de sustitución de baterías Las baterias deben cambiarse cuando el ícono se ilumina. El ícono se mantendrá iluminado hasta que las baterías tengan carga. Si el nivel de las baterías es demasiado bajo, el Check O2 Plus no se encenderá hasta que se hayan cambiado las baterías. 1. 2. 3. 4. 5. Con un destornillador #1 Phillips (estrella) afloje afloje el tornillo A de la puerta del compartimento de las baterías B y quítela. Quite las baterías. Inserte las baterías asegurándose de respetar la correcta polaridad. NO use baterías recargables. Vuelva a poner la compuerta del compartimento de baterías y apriete el tornillo. Si el Check O2 Plus no se enciende cuando termine de cambiarlas, compruebe que las baterías estén instaladas correctamente y que sean nuevas. 1176119-A 45 7 Limpieza y mantenimiento 7.1 Limpieza ¡PRECAUCIÓN! Riesgo de daños en el producto. Sea precavido en el uso del equipo para evitar que cualquier fluido penetre en el Check O2 Plus – NO sumerja el Check O2 Plus en ningún fluido. – No esterilice el Check O2 Plus con autoclaves, ni con óxido de etileno. 7.2 Mantenimiento • Sustituya las baterías por baterías AA de litio o alcalinas de alta calidad. NO use baterías recargables. • Cuando no lo vaya a utilizar por más de 30 días, quite las baterías para proteger el Check O2 Plus contra posibles derrames de las baterías. • Guarde el Check O2 Plus entre -15˚C y 60˚C Limpie las superficies exteriores del Check O2 Plus con jabón de manos o detergente para platos suave (pH 6-8). 46 1176119-A Datos técnicos 8 Datos técnicos 8.1 Parámetros Habituales del Producto OXÍGENO Rango de medición de oxígeno: (proveniente de un concentrador) Precisión de medición de oxígeno: Resolución de medición de oxígeno: 20,9 - 96% ±1,5 % a fondo de escala a temperatura constante y flujo óptimo* 0,1% de oxígeno *Ver Efectos de bajo flujo, página 43 de este manual de operación para obtener información sobre las consecuencias del flujo bajo. FLUJO Rango de medición de flujo: Precisión de medición de flujo: Resolución de medición de flujo: PRESIÓN Rango de medición de presión: Precisión de medición de presión: Resolución de medición de presión: Tiempo de respuesta: 1176119-A de 0 LPM a 10 LPM ±0,2 LPM 0,1 LPM PSI 0,5 - 50 KPA 3,4 - 344 ±0,5% ±0,5% 0,1 0,1 a 199, 1 desde 200 a 344 ≤ 17 segundos Tiempo de calentamiento: Temperatura de funcionamiento: Temperatura de almacenamiento: Presión: Humedad: Requerimientos de alimentación elétrica: Vida útil de la batería: Indicación de batería baja: Dimensiones: < 1 segundo 15°C - 40°C (59°F-104°F) -15°C - 60°C (5°F-140°F) 800 - 1000 mBares de 0 a 95% (sin condensado) 2 baterías AA alcalinas (2 x 1.5 Volteos) ≥1,100 horas (16500 ciclos de lectura) Icono de batería baja mostrado en la pantalla LCD 3.39" x 5.10" x 1.08" [86.1 mm x 125.5 mm x 25.4 mm] 0.4 libras (181 g) Peso: CLASIFICACIONES Protección contra Equipo con alimentación eléctrica interna choque elétrico: Protección contra el agua: Modo de Continuo funcionamiento: Esterilización: Ver 7.1 Limpieza, página 46. Mezcla anestésica No adecuado para utilizarse en presencia inflamable: de mezclas anestésicas inflamables Especificaciones de 1,8-3,2V 32 mW 10mA alimentación elétrica: 47 9 Garantía 9.1 Garantía limitada - Norteamérica TENGA EN CUENTA QUE LA SIGUIENTE GARANTÍA SE HA REDACTADO PARA CUMPLIR CON LAS LEYES FEDERALES APLICABLES A LOS PRODUCTOS FABRICADOS A PARTIR DEL 4 DE JULIO DE 1975. Esta garantía se extiende únicamente al comprador/usuario original de nuestros productos. Esta garantía le concede derechos legales específicos, aunque puede disponer de otros derechos legales que pueden diferir entre distintos estados. Con esta garantía, Invacare garantiza que sus productos estarán libres de defectos de materiales y mano de obra durante tres años a partir de la fecha de compra original (exceptuando ruedas y neumáticos). Si durante este período de la garantía se demuestra que los productos son defectuosos, se procederá a la reparación o sustitución de los mismos, según lo que Invacare estime oportuno. Esta garantía no incluye los gastos de mano de obra o envío derivados de la reparación o la instalación de las piezas de recambio de los productos. La única obligación de Invacare y la solución exclusiva para el usuario bajo esta garantía está limitada a dicha reparación y/o sustitución. Para obtener información sobre el servicio de la garantía, póngase en contacto con el distribuidor a quien compró el producto Invacare. En el supuesto de no recibir un servicio de garantía satisfactorio, escriba directamente a Invacare enviando una carta a la dirección postal indicada en la última página. Especifique el nombre del distribuidor, la dirección, el número de modelo, la fecha de compra, la naturaleza del defecto y, si el producto está serializado, el número de serie. Invacare Corporation emitirá una autorización de devolución. La unidad o la pieza defectuosa deberá ser devuelta para someterse a la 48 inspección de garantía en el espacio de treinta (30) días a partir de la fecha de autorización de devolución, indicando como identificación el número de serie, si procede. NO devuelva ningún producto a fábrica sin nuestro consentimiento previo. Los envíos contra reembolso no están admitidos. Por favor, pague los gastos de envío con antelación. LIMITACIONES Y EXCLUSIONES: LA GARANTÍA NO ES APLICABLE PARA LOS PROBLEMAS SURGIDOS POR EL DESGASTE NORMAL NI PARA LOS PROBLEMAS OCASIONADOS POR NO SEGUIR LAS INSTRUCCIONES ADJUNTAS. ADEMÁS, LA GARANTÍA ANTES MENCIONADA NO SE APLICARÁ A LOS PRODUCTOS CON NUMERACIÓN DE SERIE SI EL NÚMERO DE SERIE SE HA ELIMINADO O BORRADO; LOS PRODUCTOS QUE PUEDAN HABER ESTADO SOMETIDOS A UN USO NEGLIGENTE, ACCIDENTE, UTILIZACIÓN INADECUADA, MANTENIMIENTO O ALMACENAMIENTO; O LOS PRODUCTOS MODIFICADOS SIN EL CONSENTIMIENTO EXPRESO POR ESCRITO DE INVACARE, INCLUIDOS, PERO SIN LIMITARSE A: LA MODIFICACIÓN POR MEDIO DEL USO DE PIEZAS O ACCESORIOS NO AUTORIZADOS; PRODUCTOS DAÑADOS COMO CONSECUENCIA DE REPARACIONES REALIZADAS EN COMPONENTES SIN EL CONSENTIMIENTO ESPECÍFICO DE INVACARE; PRODUCTOS DAÑADOS POR CIRCUNSTANCIAS AJENAS AL CONTROL DE INVACARE; PRODUCTOS REPARADOS POR ALGUIEN QUE NO SEA DISTRIBUIDOR DE INVACARE, TAL EVALUACIÓN SOLAMENTE LA PODRÁ DETERMINAR INVACARE. LA PRESENTE GARANTÍA EXPRESA ES EXCLUSIVA E INVALIDA CUALQUIER OTRA GARANTÍA, EXPRESA O IMPLÍCITA, INCLUIDAS LAS GARANTÍAS IMPLÍCITAS DE CARÁCTER COMERCIAL Y SUJETAS A UN USO PARTICULAR; EL ÚNICO RECURSO EN CASO DE INCUMPLIMIENTO DE CUALQUIER TIPO DE GARANTÍA SE LIMITA A LA REPARACIÓN O SUSTITUCIÓN DEL PRODUCTO DEFECTUOSO TAL Y 1176119-A Garantía COMO SE ESPECIFICA EN LAS PRESENTES CONDICIONES. LA APLICACIÓN DE TODA GARANTÍA IMPLICADA NO PUEDE AMPLIAR MÁS ALLÁ DE LA DURACIÓN EXPRESA DE GARANTÍA INDICADA ANTERIORMENTE. INVACARE NO SERÁ RESPONSABLE DE NINGÚN DAÑO INCIDENTAL O DERIVADO. ESTA GARANTÍA PUEDE AMPLIARSE PARA CUMPLIR CON LAS LEYES Y REQUISITOS DE CADA ESTADO O PROVINCIA. 9.2 Garantía Invacare® garantiza el perfecto estado y funcionamiento de su producto. La garantía cubre todas las averías y defectos que de forma probada proceden de una fabricación incorrecta, mala calidad de los materiales o modelo defectuoso. Los derechos de garantía frente a Invacare® sólo pueden ser reclamados por el distribuidor, y no por el usuario del producto. Esta garantía no cubre las consecuencias del desgaste normal, de un uso incorrecto o daños, así como la falta de mantenimiento, el montaje o puesta en marcha defectuosos por parte del comprador o de terceros, o problemas que son consecuencia de circunstancias externas. La obligación de garantía se cancela cuando en el producto se han realizado modificaciones no previstas y no ejecutadas por el distribuidor especializado, así como por el empleo de recambios inapropiados. La garantía no incluye los gastos que surgen como consecuencia de la subsanación del problema, por ejemplo los fletes o transporte, costes salariales, gastos de viaje, etc. El plazo de validez de la garantía es de 24 meses. Las piezas de cierre quedan excluidas de la garantía. Además, los términos y condiciones son parte de los términos y condiciones generales específicos para cada país en el que se vende este producto. 1176119-A 49 Notes 5.1 Inhaltsverzeichnis Fehlercodes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 6 Diese Gebrauchsanweisung muss dem Benutzer des Produkts ausgehändigt werden. Lesen Sie diese Gebrauchsanweisung vor Verwendung des Produktes und bewahren Sie sie für den weiteren Gebrauch auf. Austausch der Batterien . . . . . . . . . . . . . . . . . . . . . . . . 61 6.1 Austausch der Batterien . . . . . . . . . . . . . . . . . . . . . 61 7 Reinigung und Wartung . . . . . . . . . . . . . . . . . . . . . . . . . 62 7.1 Reinigung. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 7.2 Wartung . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 1 Allgemeines. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 1.1 Symbole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 1.2 Anwendungszweck. . . . . . . . . . . . . . . . . . . . . . . . . . 52 8 Technische Daten . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 8.1 Typische Produktparameter . . . . . . . . . . . . . . . . . . . 63 9 2 Systemübersicht . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.1 Beschreibung & Arbeitsweise . . . . . . . . . . . . . . . . . . 2.2 Beschreibung der Bestandteile . . . . . . . . . . . . . . . . . 2.3 Symbolübersicht . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.4 Erklärung der Bestandteile . . . . . . . . . . . . . . . . . . . . 2.5 Lieferumfang des Geräts . . . . . . . . . . . . . . . . . . . . . Garantie . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 9.1 Garantie . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 3 Sicherheit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 3.1 Allgemeine Richtlinien . . . . . . . . . . . . . . . . . . . . . . . 55 3.2 Entsorgung . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 4 Bedienungsanweisungen . . . . . . . . . . . . . . . . . . . . . . . . 4.1 Messung von Sauerstoff, Durchfluss und Druck ....................................... 4.2 Wechsel der Druckmaßeinheit . . . . . . . . . . . . . . . . . 4.3 Überprüfung der Kalibrierung . . . . . . . . . . . . . . . . . 4.4 Faktoren, die genaue Messungen beeinträchtigen . . . . . . . . . . . . . . . . . . . . . . . . . . . . Auswirkungen der Temperatur . . . . . . . . . . . . . . . . Auswirkungen der Luftfeuchtigkeit . . . . . . . . . . . . . . Auswirkungen anderer Gase . . . . . . . . . . . . . . . . . . Auswirkungen der Luftflusses . . . . . . . . . . . . . . . . . . 5 53 53 53 54 54 54 58 58 58 58 58 58 58 59 59 Fehlercodes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 1 Allgemeines 1.1 Symbole In diesem Handbuch werden Signalwörter verwendet, um auf Gefahren oder unsichere Praktiken hinzuweisen, die zu Verletzungen oder Sachschäden führen können. Die Definitionen der verwendeten Signalwörter finden Sie in der nachfolgenden Tabelle. GEFAHR! – Das Wort Gefahr bezeichnet eine unmittelbar gefährliche Situation, die, wenn sie nicht vermieden wird, zu schweren oder tödlichen Verletzungen führt. WARNUNG! – Das Signalwort „Warnung“ weist auf eine potenziell gefährliche Situation hin, die bei Nichtbeachtung zum Tod oder zu schweren Verletzungen führen könnte. VORSICHT! – Bezeichnet eine potenziell gefährliche Situation, die, wenn sie nicht vermieden wird, zu Sachschäden oder geringfügigen Verletzungen oder beidem führen kann. Nützliche Tipps, Empfehlungen und Informationen für eine effiziente und problemlose Verwendung. 1.2 Anwendungszweck WARNUNG! – Der Check O2 Plus dient ausschließlich der Überprüfung von Sauerstoffkonzentratoren. – Verwenden Sie den Check O2 Plus NICHT für die kontinuierliche Sauerstoffüberwachung. Der Check O2 Plus darf nur von dafür geschultem Personal verwendet werden. Der Check O2 Plus Sauerstoffsensor misst mithilfe von Ultraschalltechnologie Sauerstoffkonzentration und Durchfluss und misst mithilfe eines piezoresistiven Silikondrucksensors den Druck. Der Check O2 Plus Sauerstoffsensor ist ein Gerät für die Messung von Sauerstoffreinheit, Durchfluss und Druck eines Sauerstoffkonzentrators. Der Check O2 Plus ist nicht für Patienten vorgesehen, denen Sauerstoff verschrieben wurde und es darf nicht für die kontinuierliche Überwachung oder Bestätigung der Sauerstoffbereitstellung eines Patienten eingesetzt werden. Der Check O2 Plus Sauerstoffsensor ist für die Verwendung in einer Umgebung vorgesehen, wo Sauerstoffkonzentratoren gewartet und/oder repariert werden. Das beinhaltet Krankenhäuser, Altenheime, Pflegeeinrichtungen, Patientenhäuser und Wartungs- und Reparaturwerkstätten für Atemschutzgeräte. Dieses Produkt entspricht der Richtlinie 93/42/EWG über Medizinprodukte Der Markteinführungszeitpunkt für dieses Produkt ist in der CE-Konformitätserklärung angegeben. 52 1176119-A Systemübersicht 2 Systemübersicht 2.2 Beschreibung der Bestandteile 2.1 Beschreibung & Arbeitsweise Der Check O2 Plus ist ein Sauerstoffsensor zur Überprüfung von Sauerstoffkonzentration, Durchfluss und Ausgangsdruck von Sauerstoffkonzentratoren. Das Check O2 Plus bietet aufgrund seines fortschrittlichen Designs eine unvergleichbare Leistung und Zuverlässigkeit, das die folgenden Features und Betriebsvorteile umfasst: • • • • • • • • • • • Exakte Sauerstoffmessungen. Keine Feldkalibrierung erforderlich. Bequeme Messung des Drucks in PSI oder kPa. Langlebiges, kompaktes Design. Große, einfach abzulesende Flüssigkristallanzeige (LCD). Abgeschirmter und verstärkter Einlass für Gasproben. Lange Lebensdauer mit 2 AA-Batterien. Automatische Abschaltung nach 4 Minuten. Zeigt an, wenn die Batterieindikator zur Neige geht. Selbstdiagnose. Einfache Reinigung. 1176119-A A LCD-Anzeige D Gasprobeneingang B Modustasten E Gasprobenausgang C EIN/AUS-Schalter F Batteriefach 53 2.3 Symbolübersicht 2.4 Erklärung der Bestandteile Folgende Symbole und Sicherheitsbeschriftungen sind auf dem Check O2 Plus zu finden: 3,5-Stellen-Anzeige — Das LCD bietet direktes Ablesen von Sauerstoffkonzentration, Gasfluss und Gasdruck. Auf der LCD-Anzeige werden außerdem bei Bedarf die Fehlercodes angezeigt. Autorisierter Vertreter innerhalb der Europäischen Gemeinschaft Ein-/Ausschalter Nicht wegwefen. Befolgen Sie die örtlichen Richtlinien zur Entsorgung Modustaste Bewertet durch ETL (Intertek Testing Laboratories) Batterieanzeige niedrig Hersteller Durchfluss in Liter pro Minute (l/min) Eindringschutz EIN/AUS-Schalter — Ein- oder Ausschalten des Geräts . Modustasten — Umschalten zwischen der Messung des durch einen Sauerstoffkonzentrator produzierten Gases und reinem Sauerstoff (zur Kalibrierungsüberprüfung). Batterieanzeige — Gibt an, wenn sich die Spannung der Batterien unterhalb eines normalen Betriebszustandes befindet. Pfund pro Quadratzoll l/min — Leuchtet neben der Flussmessung. (Wird im Überprüfungsmodus für die Kalibrierung nicht angezeigt). KPA — Angabe der Druckmessung in der Einheit Kilopascal. PSI — Angabe der Druckmessung in der Einheit Pfund pro Quadratzoll. “%” Symbol — Beleuchtet neben der Konzentrationsmessung. Gasprobeneingang — Verwendet für die Aufnahme der Gasprobe. Latexfrei Kilopascal Gasprobenausgang — Verwendet als Ausgang für die Gasprobe und als Auslöser für die Druckmessung, wenn verstopft. Seriennummer Prozent Schlauch für Gasprobe — Verwendet für die Verbindung zu Gasprobequellen. Katalognummer Gasprobeneingang Begleitdokumente beachten Gasprobenausgang 2.5 Lieferumfang des Geräts • Gebrauchsanweisung • Schlauch für Gasprobe • Softabdeckung Gleichspannung 54 1176119-A Sicherheit 3 Sicherheit 3.1 Allgemeine Richtlinien WARNUNG! – Dieses Kapitel enthält wichtige Informationen für den sicheren Betrieb und die sichere Verwendung dieses Produkts. – Möglicherweise vorhandenes Zubehör erst nachdem Sie diese Anweisungen und mögliches zusätzliches Anweisungsmaterial, wie zu dem Produkt gehörende Benutzerhandbücher, Servicehandbücher oder Merkblätter, vollständig gelesen und verstanden haben. Falls die Warnungen, Sicherheitshinweise und Anweisungen unverständlich sind, wenden Sie sich bite an den zuständigen Händler oder direkt an den Technischen Kundendienst von Invacare, bevor Sie die Ausrüstung verwenden - andernfalls kann es zu Verletzungen und Sachschäden kommen. WARNUNG ZUM ZUBEHÖR – Die Konstruktion und die Herstellung der Invacare-Produkte sind so speziell, dass ausschließlich Invacare-Zubehör verwendet werden darf. Zubehörteile von anderen Herstellern sind nicht von Invacare getestet worden und werden für die Verwendung mit Invacare- Produkten nicht empfohlen. 1176119-A GEFAHR! REDUZIERUNG DES RISIKOS VON VERBRENNUNGEN, STROMSCHLÄGEN, BRÄNDEN ODER KÖRPERVERLETZUNGEN – Nicht geeignet für den Einsatz bei Anästhesieanwendungen oder für die Messung der Sauerstoffkonzentration von Quellen außer herkömmlicher Sauerstoffkonzentratoren. – Nicht geeignet für die Verwendung mit Inhalationsmitteln. Der Betrieb des Check O2 Plus in brennbarer oder explosiver Atmosphäre kann zu Feuer oder einer Explosion führen. – Nicht geeignet zur Verwendung mit brennbaren Anästhesiegasgemischen. – Sauerstoff fördert eine rasche Verbrennung. Während der Verwendung des Check O2 Plus für die Überprüfung von Sauerstoffkonzentratoren darf nicht geraucht werden. – Nicht zur Verwendung in einer MRI-Umgebung geeignet. 55 WARNUNG! Eine unsachgemäße Verwendung des Check O2 Plus kann zu falschen Sauerstoffmesswerten und dadurch zu einer falschen Behandlung und/oder zu Schädigungen des Patienten kommen. Befolgen Sie die in dieser Anleitung dargestellten Vorgehensweisen. – Vor dem Gebrauch müssen sich alle Personen gründlich mit den in dieser Anleitung bereitgestellten Information vertraut machen. Für eine sichere und effektive Produktleistung müssen Sie sich streng an alle Betriebs- und Wartungsanweisungen halten. Die Leistungsfähigkeit dieses Produkts ist nur dann gewährleistet, wenn es in Übereinstimmung mit den Anweisungen des Herstellers installiert und betrieben wird. – Verwenden Sie den Check O2 Plus NICHT für die Messung der Sauerstoffkonzentration eines Konzentrators, wenn die Durchflussrate unter der vom Konzentratorhersteller angegebenen Leistung liegt; im Allgemeinen 4 l/min oder weniger bei Konzentratoren mit einem maximalen Durchfluss von 10 l/min und 1 l/min oder weniger mit Konzentratoren mit einem maximalen Durchfluss von 5 l/min. – Wenn Sie den Check O2 Plus in der Nähe von Geräten verwenden, die elektrische Felder erzeugen, erhalten Sie möglicherweise ungenaue Messungen. 56 WARNUNG! – Sollte der Check O2 Plus jemals Flüssigkeiten (durch Verschütten oder Untertauchen) ausgesetzt werden, dann entfernen Sie umgehend die Batterien und lassen das Gerät vollständig trocknen. Sobald das Gerät trocken ist, ersetzen Sie die Batterien und prüfen es auf korrekten Betrieb. – Das Check O2 Plus darf niemals autoklaviert oder hohen Temperaturen ausgesetzt werden (>60 °C). – Verwenden Sie KEINE Ethylenoxid-Sterilisation. – Setzen Sie den Check O2 Plus NIEMALS Druck, Bestrahlung, Vakuum, Dampf oder Chemikalien aus. – Verwenden Sie für das Check O2 Plus KEINEN höheren Druck als 50 psi. Die Anwendung von Druck über 50 psi kann zu Lecks am Gerät führen, die sich negativ auf die Durchflussleistung und auf das Ablesen der Druckwerte auswirken können. – Reparaturen oder Manipulation des Check O2 Plus über das in den Wartungsanleitungen beschriebene Maß hinaus oder von anderen Personen, die nicht wie vorgeschrieben von Invacare geschult oder eingewiesen worden sind, kann den ordnungsgemäßen Betrieb des Geräts beeinträchtigen. 1176119-A Sicherheit VORSICHT! – Ersetzen Sie die Batterien mit hochwertigen AA-Alkalioder Lithium-Batterien. Verwenden Sie KEINE wiederaufladbaren Batterien. – Um das Gerät vor Beschädigungen durch eine auslaufende Batterie zu schützen, entfernen Sie die Batterien stets, wenn das Check O2 Plus aufbewahrt wird (1 Monat lang nicht in Gebrauch). – Vermeiden Sie ein Herunterfallen des Check O2 Plus , um so Beschädigungen zu vermeiden, die sich negativ auf die Leistung auswirken können. Wird eine Beschädigung des Geräts vermutet, führen Sie 4.3 Überprüfung der Kalibrierung , Seite 58. – Führen Sie keine Fremdkörper in das Check O2 Plus ein. – Verwenden Sie das Check O2 Plus NICHT für die Überprüfung eines Konzentrators bei gleichzeitig vorhandenem Befeuchtungsgerät. Die Feuchtigkeit eines Befeuchtungsgeräts könnte das Gerät beschädigen. – Überprüfen Sie den Konzentrator NICHT, während Sie die Modustaste drücken, oder es werden falsche Werte abgelesen. – Nach der Lagerung des Geräts unter extrem heißen oder kalten Bedingungen muss das Gas solange durch das Analysegerät fließen, bis die internen Sensoren die Temperatur des Gasstroms erreichen, oder man wartet mit der Verwendung des Geräts, bis sich das Analysegerät der Raumtemperatur angepasst hat. 1176119-A 3.2 Entsorgung Dieses Produkt ist von einem umweltbewussten Hersteller geliefert worden, der gemäß der Verordnung 2002/96/CE zurEntsorgung von Elektro‐ bzw. Elektronikschrott (WEEE) arbeitet Dieses Produkt kann Stoffe enthalten, die sich für die Umwelt als schädlich erweisen könnten, falls sie an Orten (Mülldeponien) entsorgt werden, die nach der Gesetzgebung dafür nicht geeignet sind. Wir bitten Sie, umweltverträglich zu handeln und dieses Produkt nach Ende seiner Lebensdauer über eine lokale Müllverwertungsanlage recyceln zu lassen. Die Batterien und Platine eignen sich nicht für die Entsorgung im normalen Hausmüll. 57 4 Bedienungsanweisungen 4.1 Messung von Sauerstoff, Durchfluss und Druck Überprüfung von Sauerstoffkonzentration, Durchfluss und Druck einer Gasprobe von einem Konzentrator: 1. 2. 3. 4. 5. 6. 7. Verbinden Sie den Gasprobenschlauch mit dem Gasprobeneingang vom Check O2 Plus. Befestigen Sie das andere Ende des Gasprobenschlauchs mit dem Sauerstoffkonzentrator. Starten Sie den Gasfluss vom Check O2 Plus mit einer Rate von 1-10 Litern pro Minute (2 Liter pro Minute wird empfohlen). Stellen Sie sicher, dass der Ausstoß des Konzentrators den Empfehlungen des Herstellers im Bezug auf Stabilität entspricht. Schalten Sie den Check O2 Plus ein. Warten Sie vor dem Ablesen von Sauerstoffkonzentration und Durchfluss 10 Sekunden ab, bis sich der Wert stabilisiert hat. Um den Druck zu überprüfen, decken Sie den Gasprobenausgang während des Gasflusses mit Daumen und Finger ab. Warten Sie 5 Sekunden bis zum Ablesen des Drucks. Drücken Sie während der Überprüfung eines Konzentrators NICHT die Modustaste oder es werden falsche Werte abgelesen. 4.2 Wechsel der Druckmaßeinheit Das Check O2 Plus kann den Druck in PSI oder kPa messen. Das Check O2 Plus ist ab Werk auf PSI eingestellt. Umschalten auf kPa: 1. 2. 3. 58 Lösen Sie mit einem Kreuzschlitzschraubenzieher Größe 1 die Schraube des Batteriefachdeckels und entfernen Sie den Deckel. Betätigen Sie den Schalter im Batteriefach. Bringen Sie den Batteriefachdeckel wieder an und ziehen Sie die Schraube des Batteriefachdeckels wieder fest. 4.3 Überprüfung der Kalibrierung Mit dem Modus für die Kalibrierungsüberprüfung kann überprüft werden, ob das Check O2 Plus korrekt funktioniert. So wird die Kalibrierungsüberprüfung durchgeführt: 1. 2. 3. 4. Schalten Sie das Check O2 Plus ein. Verbinden Sie eine Quelle mit reinem Sauerstoff (≥99,95 %) mit dem Gasprobeneingang. Lassen Sie 2-5 l/min Gas in den Check O2 Plus fließen. Stellen Sie sicher, dass der Gasfluss zum Check O2 Plus bei einer stabilen Temperatur stattfindet. Drücken und halten Sie den "Mode" Schalter. Während Sie den Schalter gedrückt halten, sollten die Werte zwischen 98,5 und 101,5 % Sauerstoff liegen. Wenn die Werte außerhalb dieser Spanne liegen, rufen Sie bitte den Kundenservice an. Im Kalibrierungsmodus leuchtet auf dem Bildschirm "CAL" und "VER" unterhalb der Anzeige für die Sauerstoffwerte 4.4 Faktoren, die genaue Messungen beeinträchtigen Auswirkungen der Temperatur Das Check O2 Plus kompensiert die Temperatur und arbeitet innerhalb des Betriebstemperaturbereichs innerhalb der Spezifikationen. Die Durchführung von Messungen während schneller Änderungen der Gastemperatur sollte jedoch vermieden werden. Auswirkungen der Luftfeuchtigkeit Das Check O2 Plus verfügt über einen Feuchtigkeitssensor für die Erkennung und Kompensierung der Feuchtigkeit von Gas, das in das Gerät gelangt. Hohe Mengen an Feuchtigkeit (Kondensierung) können die Genauigkeit und Zuverlässigkeit des Check O2 Plus beeinflussen. So vermeiden Sie mögliche Schäden: 1176119-A Bedienungsanweisungen • Vermeiden Sie den Gebrauch in Umgebungen mit mehr als 95 % Auswirkungen der Luftflusses relativer Luftfeuchtigkeit. • Verwenden Sie dieses Gerät NICHT in einem Beatmungskreis. • Atmen oder blasen Sie NICHT in das Check O2 Plus. Sauerstoffkonzentratoren funktionieren nach dem Prinzip des Entfernens von Stickstoff aus der Luft und übrig bleibt konzentrierter Sauerstoff und Argonin einem bestimmten Verhältnis. Dieses Betriebsprinzip kann sich ändern, wenn die Konzentratoren für einen Durchfluss am unteren Ende ihres Betriebsbereichs eingestellt sind. Bei niedrigen Durchflüssen geben sie eventuell eine niedrige Sauerstoffkonzentration aus, wie z. B. 85 % bis 91 %, was nicht am hohen Stickstoff liegt, sondern wahrscheinlich an einer Erhöhung des Argon. Das Check O2 Plus erfordert ein konstantes Verhältnis von Sauerstoff und Argon, um so eine Genauigkeit von +/- 1,5 % Sauerstoff zu gewährleisten. Auswirkungen anderer Gase Mit dem Check O2 Plus können zwei verschiedene Arten von Gasmischungen gemessen werden: • Sauerstoff, Stickstoff und Argon aus Sauerstoffkonzentratoren. • Purer Sauerstoff während des Modus Kalibrierungsüberprüfung. Alle anderen Konzentrationen oder Kombinationen aus Gasen führen mit dem Check O2 Plus zu falschen Messergebnissen. • Verwenden Sie das Check O2 Plus NICHT für die Messung der Sauerstoffkonzentration eines Konzentrators, wenn die Durchflussrate unter der vom Konzentratorhersteller angegebenen Leistung liegt; im Allgemeinen 4 l/min oder weniger bei Konzentratoren mit einem maximalen Durchfluss von 10 l/min und 1 l/min oder weniger mit Konzentratoren mit einem maximalen Durchfluss von 5 l/min. 1176119-A 59 5 Fehlercodes 5.1 Fehlercodes Das Check O2 Plus verfügt über Selbstdiagnosefunktionen in der Software für die Erkennung fehlerhafter Ablesungen außerhalb des normalen Betriebsbereichs. Hier die Codes, Beschreibungen und empfohlenen Maßnahmen: • E01: Sauerstoffmessung außerhalb des Bereichs High (≥102,0 % • • • • 60 berechnet per Algorithmus). Empfohlene Maßnahme: Überprüfen Sie, ob das Check O2 Plus im korrekten Modus verwendet wird (Konzentrator oder Modus für Kalibrierungsüberprüfung). Falls der Fehlercode wiederholt angezeigt wird, führen Sie eine Kalibrierungsüberprüfung durch, wie in Abschnitt 4.3 dieses Handbuchs erläutert. Wird der Fehlercode erneut angezeigt, wenden Sie sich an den Kundendienst. E02: Sauerstoffmessung außerhalb des Bereichs Low (≤-2,0 % berechnet per Algorithmus). Empfohlene Maßnahme: Überprüfen Sie, ob der Check O2 Plus im korrekten Modus verwendet wird (Konzentrator oder Modus für Kalibrierungsüberprüfung). Falls der Fehlercode wiederholt angezeigt wird, führen Sie eine Kalibrierungsüberprüfung durch, wie in Abschnitt 4.3 dieses Handbuchs erläutert. Wird der Fehlercode erneut angezeigt, wenden Sie sich an den Kundendienst. E03: Gerätespeicher fehlerhaft oder fehlt. Empfohlene Maßnahme: Schicken Sie den Check O2 Plus zum Hersteller zurück, um es dort reparieren zu lassen. E04: Signalmessung nicht stabil. Empfohlene Maßnahme: Schicken Sie den Check O2 Plus zum Hersteller zurück, um es dort reparieren zu lassen. E05: Druckmessung außerhalb des Bereichs High (≥50 PSI). Empfohlene Maßnahme: Überprüfen Sie den Druck der Gasquelle. Wird der Fehlercode erneut angezeigt, wenden Sie sich an den Kundendienst. • E06: Außerhalb der Betriebstemperatur High (≥40° C). Empfohlene Maßnahme: Der Check O2 Plus ist zu heiß, lassen Sie das Gerät vor der Verwendung auf Raumtemperatur abkühlen. • E07: Außerhalb der Betriebstemperatur Low (≤15° C). Empfohlene Maßnahme: Der Check O2 Plus ist zu heiß, lassen Sie das Gerät vor der Verwendung auf Raumtemperatur abkühlen. • E08: Geräteselbstüberprüfung hat einen Fehler gefunden. Empfohlene Maßnahme: Entfernen und ersetzen Sie die Batterien. Tritt der Fehlercode erneut auf, schicken Sie den Check O2 Plus an den Hersteller zurück, um es dort reparieren zu lassen. 1176119-A Austausch der Batterien 6 Austausch der Batterien 6.1 Austausch der Batterien Sollten die Batterien ausgewechselt werden müssen leuchtet das Symbol . Das Symbol leuchtet solange, bis die Batterien ausgetauscht wurden. Ist die Batterieleistung zu schwach, lässt sich der Check O2 Plus solange nicht einschalten, bis die Batterien ausgetauscht wurden. 1. 2. 3. 4. 5. Lösen Sie mit einem Kreuzschlitzschraubenzieher Größe 1 die Schraube des Batteriefachdeckels B und entfernen Sie den Deckel A. Entfernen Sie die Batterien. Legen Sie die Batterien der Aufschrift entsprechend ein. Verwenden Sie KEINE wiederaufladbaren Batterien. Bringen Sie den Batteriefachdeckel wieder an und ziehen Sie die Schraube des Batteriefachdeckels wieder fest. Wenn die Batterien falsch installiert wurden oder die Batterien leer sind gibt es keinen Kontakt und der Check O2 Plus funktioniert nicht. 1176119-A 61 7 Reinigung und Wartung 7.2 Wartung 7.1 Reinigung Lithium-Batterien. Verwenden Sie KEINE wiederaufladbaren Batterien. • Um das Gerät vor Beschädigungen durch eine auslaufende Batterie zu schützen, entfernen Sie die Batterien stets, wenn der Check O2 Plus aufbewahrt wird (1 Monat lang nicht in Gebrauch). • Lagern Sie der Check O2 Plus zwischen -15˚ C und 60˚ C (5˚ F 140˚ F) VORSICHT! Risiko von Produktschäden Achten Sie darauf, dass keine Flüssigkeit in den Check O2 Plus eindringt. – Tauchen Sie den Check O2 Plus NICHT in Flüssigkeiten ein. – Der Check O2 Plus darf NIEMALS autoklaviert oder einer Sterilisation mit Methylenoxid ausgesetzt werden. • Ersetzen Sie die Batterien mit hochwertigen AA-Alkali- oder Reinigen Sie die Oberfläche des Check O2 Plus mit einem feuchten Lappen und einer milden Handseife oder einem Geschirrspülmittel (pH 6-8). 62 1176119-A Technische Daten 8 Technische Daten 8.1 Typische Produktparameter SAUERSTOFF Betriebstemperatur: 15°C - 40°C (59°F-104°F) Lagertemperatur: –15°C - 60°C (5°F-140°F) Druck: 800 - 1000 mBar Luftfeuchtigkeit: 0 - 95% (nicht kondensierend) Stromanforderungen: 2 AA Alkalibatterien (2 x 1,5 Volt) Sauerstoffmessbereich: (von einem Konzentrator) 20,9 - 96% Akkuhaltbarkeit: Sauerstoffmessgenauigkeit: ±1,5 % der Gesamtskala bei konstanter Temperatur und optimalem Durchfluss* ≥1100 Stunden (16,500 Lesezyklen) Niedriger Ladezustand der Batterie: Symbol für niedrigen Ladezustand auf LCD-Anzeige Sauerstoffmessauflösung: 0,1% Sauerstoff Abmessungen: 3,39" x 5,10" x 1,00" [86,1mm x 125,5mm x 25,4mm] Gewicht: 0,4 Pfd. (181 g) Siehe Auswirkungen der Luftflusses, Seite 59 dieser Anleitung für Informationen über die Auswirkungen von geringem Durchfluss. Schutz vor elektrischem Schlag: DURCHFLUSS Durchflussmessbereich: 0 - 10 l/min Durchflussmessgenauigkeit: ±0,2 l/min Durchflussmessauflösung: 0,1 l/min DRUCK PSI kPa Druckmessbereich: 0,5 - 50 Druckmessgenauigkeit: ±0,5% Druckmessbereichauflösung: 0,1 Reaktionszeit: ≤ 17 Sekunden Aufwärmzeit: < 1 Sekunde 1176119-A KLASSIFIZIERUNG Intern betriebenes Gerät Vor Wasser schützen: Betriebsmodus: Dauerbetrieb Sterilisation: Siehe 7.1 Reinigung, Seite 62. 3,4 - 344 Brennbare Anästhesiegasgemische: Nicht geeignet zur Verwendung mit brennbaren Gemischen ±0,5% Stromanforderungen: 1,8 - 3,2 V 32 mW 10mA 0,1bis zu 199, 1 von 200 bis 344 63 9 Garantie 9.1 Garantie Invacare® garantiert für Mängelfreiheit und Funktionstüchtigkeit Ihres Produkts. Die Garantie erstreckt sich auf alle Fehler und Defekte, welche nachweisbar infolge fehlerhafter Bauart, schlechten Materials oder mangelhafter Ausführung entstanden sind. Garantieansprüche gegenüber Invacare® kann nur der Vertriebspartner, nicht der Endkunde geltend machen. Nicht unter die Garantie fallen normale Abnützung, die Folgen unsachgemässer Behandlung oder Beschädigung, mangelnde Wartung und fehlerhafte Montage oder Inbetriebnahme durch den Käufer oder Drittpersonen sowie Mängel, die auf äussere Umstände zurückzuführen sind. Verschleissteile sind von der Garantie ausgeschlossen. Die Garantieverpflichtung erlischt, wenn am Produkt nicht vorgesehene und nicht vom Fachhändler ausgeführte Veränderungen vorgenommen wurden oder bei Verwendung ungeeigneter Ersatzteile. Die Gewährleistung von Invacare® erstreckt sich nicht auf aus der Mängelbeseitigung entstehende Folgekosten wie Fracht- und Fahrkosten, Lohnkosten, Spesen etc. Die Garantiefrist beträgt 24 Monate. Darüber hinaus sind die Garantiebedingungen Teil der Allgemeinen Geschäftsbedingungen, die im jeweiligen Land gelten, in dem das Produkt gekauft wurde. 64 1176119-A Sommario 6 Sostituzione delle batterie. . . . . . . . . . . . . . . . . . . . . . . 75 6.1 Procedura di sostituzione delle batterie . . . . . . . . . . 75 Il presente manuale deve essere fornito all'utilizzatore del prodotto. Leggere il presente manuale e conservarlo per eventuali consultazioni successive, PRIMA di utilizzare il prodotto. 7 Pulizia e manutenzione . . . . . . . . . . . . . . . . . . . . . . . . . 76 7.1 Pulizia . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 7.2 Manutenzione . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 1 8 Dati tecnici . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 8.1 Parametri tipici del prodotto. . . . . . . . . . . . . . . . . . . 77 9 Garanzia commerciale . . . . . . . . . . . . . . . . . . . . . . . . . . 9.1 Garanzia commerciale . . . . . . . . . . . . . . . . . . . . . . . Condizioni generali . . . . . . . . . . . . . . . . . . . . . . . . . Limitazioni di responsabilità . . . . . . . . . . . . . . . . . . . Durata della garanzia . . . . . . . . . . . . . . . . . . . . . . . . Generalità . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 1.1 Simboli . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 1.2 Uso previsto . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 2 Panoramica del sistema . . . . . . . . . . . . . . . . . . . . . . . . . 2.1 Descrizione e principio di funzionamento . . . . . . . . . 2.2 Identificazione dei componenti . . . . . . . . . . . . . . . . . 2.3 Guida dei simboli . . . . . . . . . . . . . . . . . . . . . . . . . . 2.4 Descrizione dei componenti . . . . . . . . . . . . . . . . . . 2.5 Inclusi con l'unità . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Sicurezza . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 3.1 Guide Linea Generali . . . . . . . . . . . . . . . . . . . . . . . . 69 3.2 Smaltimento . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 4 Istruzioni Operative . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1 Misurazione di ossigeno, flusso e pressione . . . . . . . . 4.2 Cambiamento dell'unità di misura della pressione ....................................... 4.3 Procedura di verifica della calibratura . . . . . . . . . . . . 4.4 Fattori che influenzano la precisione delle letture. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Effetti della temperatura . . . . . . . . . . . . . . . . . . . . . Effetti dell'umidità . . . . . . . . . . . . . . . . . . . . . . . . . . Effetti di altri gas . . . . . . . . . . . . . . . . . . . . . . . . . . . Effetti del flusso basso . . . . . . . . . . . . . . . . . . . . . . . 5 67 67 67 68 68 68 72 72 72 72 72 72 73 73 73 Codici di errore. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 5.1 Codici di Errore . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 78 78 78 78 78 1 Generalità 1.1 Simboli Nel presente manuale sono evidenziate con simboli tutte quelle situazioni non sicure o pericolose che possono portare a lesioni personali o danni materiali. Vedere le spiegazioni qui di seguito di tutti i possibili avvertimenti. 1.2 Uso previsto ATTENZIONE! – Check O2 Plus è destinato unicamente a verificare i concentratori di ossigeno. – NON usare Check O2 Plus per il monitoraggio continuo dell'ossigeno. l'uso di Check O2 Plus è consentito solo al personale addestrato. PERICOLO! – Pericolo indica una situazione di pericolo imminente che, se non evitata, provoca il decesso o lesioni gravi. ATTENZIONE! – Situazione di pericolo potenziale che, se non evitata, potrebbe essere causa di morte o lesioni gravi. AVVERTENZA! – Attenzione indica una situazione di potenziale pericolo che, se non evitata, può provocare danni alle cose e/o lesioni non gravi. Indica consigli utili, raccomandazioni e informazioni per un uso efficace e senza inconvenienti. L'analizzatore di ossigeno Check O2 Plus misura la concentrazione e il flusso dell'ossigeno grazie alla tecnologia ultrasonica e misura la pressione utilizzando un sensore in silicone piezoresistivo. L'analizzatore di ossigeno Check O2 Plus è uno strumento utile per misurare la purezza, il flusso e la pressione dell'ossigeno all'uscita di un concentratore di ossigeno. Non deve essere usato dai pazienti cui sia stata prescritta l'ossigenoterapia e non è stato progettato per monitorare o verificare in modo continuativo l'erogazione di ossigeno al paziente. L'analizzatore di ossigeno Check O2 Plus è stato progettato per funzionare in ambienti dove vengono sottoposti a manutenzione o riparazione i concentratori di ossigeno. Tali ambienti includono ospedali, unità post intervento, strutture per lungodegenti, domicili dei pazienti e centri per la manutenzione e la riparazione dei dispositivi respiratori. Questo prodotto è conforme alla direttiva 93/42/CEE riguardante i dispositivi medici. La data di lancio di questo prodotto è indicata nella dichiarazione di conformità CE. 66 1176119-A Panoramica del sistema 2 Panoramica del sistema 2.2 Identificazione dei componenti 2.1 Descrizione e principio di funzionamento Check O2 Plus è un analizzatore di ossigeno progettato per verificare la concentrazione, il flusso e la pressione d'uscita dell'ossigeno dei concentratori di ossigeno. Check O2 Plus fornisce prestazioni e affidabilità senza eguali, grazie alla sua progettazione avanzata che include i seguenti aspetti e vantaggi operativi: • • • • • • • • • • • Misurazioni accurate dell'ossigeno. Nessuna necessità di taratura sul campo. Possibilità di misurare la pressione in PSI o kPa. Dispositivo compatto e affidabile. Display a cristalli liquidi (LCD) ampio e di facile lettura. Bocchetta d'ingresso gas campione schermata e rinforzata. Lunga durata delle batterie grazie a 2 pile AA. Spegnimento automatico dopo 4 minuti. Indicazione batteria debole. Autodiagnosi. Facile da pulire. 1176119-A A Display LCD D Ingresso campione gas B Pulsante di modalità E Uscita campione gas C Pulsante ACCESO/SPENTO F Sportello batterie 67 2.3 Guida dei simboli 2.4 Descrizione dei componenti Check O2 Plus riporta i seguenti simboli ed etichette di sicurezza: Display a 3 cifre intere più una cifra decimale: lo schermo LCD fornisce letture dirette per la concentrazione di ossigeno, il flusso e la pressione. Il display LCD mostra anche i codici di errore, se necessario. 68 Rappresentante autorizzato nella Comunità europea Pulsante Acceso/ Spento Non gettare con i rifiuti generici. Seguire le linee guida locali per lo smaltimento Pulsante di modalità Valutato da ETL (Intertek Testing Laboratories) Batteria debole Fabbricante Flusso in litri per minuto Solo protezione in ingresso Libbra-forza per pollice quadrato Privo di lattice Kilopascal Numero di serie Percentuale Numero di catalogo Ingresso campione gas Consultare i documenti di accompagnamento Uscita campione gas 2.5 Inclusi con l'unità Corrente continua • Manuale d’uso • Tubi campione gas • Astuccio morbido Pulsante ACCESO/SPENTO: accende e spegne il dispositivo. Pulsante di modalità: permette di passare dalla misurazione della concentrazione del gas prodotto da un concentratore di ossigeno a quella dell'ossigeno puro e viceversa (per la verifica della calibratura). Indicatore di batteria debole: indica se la tensione delle batterie è inferiore ai livelli operativi normali. LPM: indicatore luminoso accanto alla misurazione del flusso. (Non acceso nella modalità di verifica della calibratura). KPA: indica che la pressione viene misurata in kilopascal. PSI: indica che la pressione viene misurata in libbre forza per pollice quadrato. Simbolo di "%": indicatore luminoso accanto alla misurazione della concentrazione. Ingresso campione gas: serve a ricevere il campione di gas. Uscita campione gas: serve per far uscire il campione di gas ed è dotato di un trigger per la misurazione della pressione quando tale uscita viene chiusa. Tubi campione gas: servono a collegare le fonti dei campioni di gas. 1176119-A Sicurezza 3 Sicurezza 3.1 Guide Linea Generali ATTENZIONE! – Questa sezione contiene informazioni importanti per il funzionamento e lʹutilizzo in sicurezza di questo prodotto. – NON USARE questo prodotto o nessun altro dispositivo opzionale disponibile senza prima aver letto attentamente e compreso fino in fondo le presenti istruzioni ed ogni altro materiale informativo come manuale utente, manuale per la manutenzione o fogli di istruzione forniti con questo prodotto o con I kit aggiuntivi. Nel caso in cui segnalazioni, avvisi o istruzioni fossero di difficile comprensione, contattare personale medico, il rivenditore o tecnici adeguatamente preparati prima di iniziare ad utilizzare queste attrezzature; in modo da evitare ogni possibile lesione personale o danno. AVVERTENZA ACCESSORI – I prodotti Invacare sono appositamente progettati e costruiti per essere utilizzati in combinazione con accessori Invacare. Accessori progettati da altri costruttori non sono stati collaudati da Invacare e se ne sconsiglia l'uso con i prodotti Invacare. 1176119-A PERICOLO! RIDURRE IL RISCHIO DI USTIONI,SCOSSE, INCENDIO O LESIONI PERSONALI – Non utilizzare in applicazioni anestetiche, né per misurare la concentrazione di ossigeno da fonti diverse dai tradizionali concentratori di ossigeno. – Non utilizzare con agenti inalatori. Il funzionamento di Check O2 Plus in atmosfere infiammabili o esplosive può causare incendi o esplosioni. – Non idoneo per l’uso in presenza di miscele anestetiche infiammabili. – L'ossigeno accelera rapidamente la combustione. Non fumare durante l'uso di Check O2 Plus per la verifica dei concentratori di ossigeno. – Non utilizzare in ambiente RM. 69 ATTENZIONE! L'uso improprio di Check O2 Plus può causare letture non accurate dell’ossigeno con conseguenti errori nel trattamento e/o danni a carico del paziente. Seguire le procedure illustrate nel manuale dell’utente. – Prima dell’uso, gli operatori devono familiarizzarsi perfettamente con le informazioni contenute nel manuale operativo. La sicurezza, l’efficacia e le prestazioni del prodotto dipendono dalla stretta aderenza alle istruzioni operative. Questo prodotto funziona come progettato solo se messo in funzione secondo le istruzioni operative del produttore. – NON usare Check O2 Plus per misurare la concentrazione di ossigeno di un concentratore quando i relativi flussi sono inferiori a quelli ottimali specificati dal produttore del concentratore, cioè solitamente 4 LPM o meno su concentratori con flusso massimo di 10 LPM e 1 LPM o meno su concentratori con flusso massimo di 5 LPM. – L'uso di Check O2 Plus in prossimità di dispositivi che generano campi elettromagnetici può causare letture irregolari. 70 ATTENZIONE! – Nel caso in cui Check O2 Plus sia esposto a liquidi derivanti da perdite o immersione, rimuovere immediatamente le batterie e lasciar asciugare perfettamente il dispositivo. Una volta asciutto, reinserire le batterie e verificare che il dispositivo funzioni correttamente. – NON sterilizzare in autoclave, né esporre Check O2 Plus a temperature elevate (>60°C). – NON utilizzare metodi di sterilizzazione a ossido di etilene. – NON esporre Check O2 Plus a radiazioni, pressioni negative, vapore o sostanze chimiche aggressive. – NON esporre Check O2 Plus a pressioni superiori a 50 PSI (3,5 atm). L'esposizione a pressioni superiori a 50 PSI (3,5 atm) potrebbe causare perdite nel dispositivo, tali da influenzare negativamente le prestazioni in termini di flusso e letture della pressione. – La riparazione o la modifica di Check O2 Plus da parte di soggetti diversi dal personale del servizio assistenza Invacare autorizzato potrebbe impedire al prodotto di funzionare come progettato. 1176119-A Sicurezza AVVERTENZA! – Sostituire le batterie con pile AA alcaline o al litio di alta qualità. NON utilizzare batterie ricaricabili. – Quando si prevede di non utilizzare l'unità per oltre 30 giorni, rimuovere le batterie per proteggere UltraMaxO2 da possibili danni dovuti a fuoruscite di elettrolito. – Evitare di far cadere Check O2 Plus per prevenire danni che potrebbero influire negativamente sulle sue prestazioni. Se si sospettano danni al dispositivo, eseguire la procedura 4.3 Procedura di verifica della calibratura , pagina 72 del manuale operativo. – Evitare l'ingresso di materiale estraneo nell'unità Check O2 Plus. – NON usare Check O2 Plus per verificare concentratori con l'umidificatore in sede. L'umidità proveniente dall'umidificatore potrebbe danneggiare il dispositivo. – NON verificare un concentratore tenendo premuto il pulsante di modalità per evitare letture imprecise. – Dopo lo stoccaggio a temperature estremamente alte o basse, lasciare fluire il gas attraverso l'analizzatore per il tempo necessario a far raggiungere ai sensori interni la temperatura del flusso gassoso. In alternativa, attendere che l'analizzatore raggiunga l'equilibrio a temperatura ambiente prima di utilizzarlo. 1176119-A 3.2 Smaltimento Questo prodotto è stato fornito dal fabbricante nel rispetto dellʹambiente e in conformità alla direttiva 2002/96/CE sui rifiuti di apparecchiature elettriche ed elettroniche (RAEE). Questo prodotto potrebbe contenere delle sostanze nocive allʹambiente se smaltite in maniera non corretta o lasciate in punti di raccolta non appropriati e non conformi a quanto previsto dalla legislazione vigente. Vi invitiamo a prendervi cura dell'ambiente in modo responsabile, riciclando questo prodotto attraverso i servizi di riciclaggio della vostra zona, al termine del suo utilizzo. Le batterie e il circuito stampato non sono idonei per lo smaltimento come rifiuti generici. 71 4 Istruzioni Operative 4.1 Misurazione di ossigeno, flusso e pressione Per verificare la concentrazione di ossigeno, il flusso e la pressione di un campione di gas da un concentratore: 1. 2. 3. 4. 5. 6. 7. Collegare i tubi campione gas all'ingresso campione gas di Check O2 Plus. Collegare l'altra estremità dei tubi campione gas al concentratore di ossigeno. Impostare il flusso gassoso nell'unità Check O2 Plus su una portata di 1-10 litri per minuto (si raccomandano 2 litri per minuto). Accertarsi che l'uscita del concentratore sia stabile come raccomandato dal fabbricante del dispositivo. Accendere l'unità Check O2 Plus. Lasciare che la lettura dell'ossigeno si stabilizzi per almeno 10 secondi prima di leggere la concentrazione e il flusso di ossigeno. Per verificare la pressione, bloccare l'uscita campione gas con il pollice o un altro dito mentre il gas sta fluendo. Attendere 5 secondi finché non appare la lettura della pressione sul display. NON verificare un concentratore tenendo premuto il pulsante di modalità per evitare letture imprecise. 4.2 Cambiamento dell'unità di misura della pressione Check O2 Plus può misurare la pressione in PSI o kPa. Check O2 Plus è impostato franco fabbrica per eseguire misurazioni in PSI. Per passare ai kPa: 72 1. 2. 3. Impiegando un cacciavite Phillips n.1 allentare la vite dello sportello batterie e rimuovere quest'ultimo. Cambiare la posizione del deviatore dentro lo scomparto batterie. Rimettere in sede lo sportello batterie e stringere la relativa vite. 4.3 Procedura di verifica della calibratura Check O2 Plus è dotato di una modalità di verifica della calibratura che serve ad accertarne il funzionamento corretto. Per eseguire la verifica della calibratura 1. 2. 3. 4. Accendere l'unità Check O2 Plus. Collegare una fonte di ossigeno puro (≥99,95%) all'ingresso campione gas. Lasciar fluire 2-5 LPM di gas nell'unità Check O2 Plus. Accertarsi che la temperatura del gas che fluisce nell'unità Check O2 Plus sia stabile. Premere senza rilasciare il pulsante di modalità. Mentre si tiene premuto il pulsante di modalità, la misurazione del gas deve indicare valori dell'ossigeno compresi tra 98,5% e 101,5%. Se la misurazione del gas non è compresa in questo intervallo, chiamare l'Assistenza clienti. La modalità di verifica della calibratura è indicata dalle scritte lampeggianti "CAL" e "VER" sul display, sotto al valore misurato del gas. 4.4 Fattori che influenzano la precisione delle letture Effetti della temperatura L'unità Check O2 Plus compensa le variazioni indotte dalla temperatura e funziona correttamente entro le specifiche per tutta la gamma della temperatura di funzionamento. È tuttavia preferibile evitare di eseguire le misurazioni durante rapide variazioni nella temperatura del gas. 1176119-A Istruzioni Operative Effetti dell'umidità Effetti del flusso basso Check O2 Plus è dotato di un sensore per rilevare l'umidità e compensare le variazioni indotte da quest'ultima sul gas che entra nel dispositivo. Livelli elevati di umidità (condensa) possono tuttavia influenzare la precisione e l'affidabilità di Check O2 Plus. Per prevenire eventuali danni: I concentratori di ossigeno agiscono secondo il principio di rimuovere il gas di azoto dall'aria, lasciando ossigeno concentrato e argon secondo uno specifico rapporto ossigeno/argon. Il principio di funzionamento può essere alterato quando i concentratori vengono impostati su flussi all'estremità inferiore della loro intervallo operativo. A bassi flussi possono erogare una concentrazione di ossigeno inadeguata, ad es. dall'85% al 91%, per motivi diversi dal contenuto elevato in azoto, probabilmente a causa di un aumento nel contenuto di argon. Per garantire una precisione di +/-1,5% di ossigeno, l'unità Check O2 Plus richiede che il rapporto ossigeno/argon resti costante. • Evitare l'uso in ambienti con umidità relativa superiore al 95%. • NON usare il dispositivo nei circuiti respiratori. • NON infondere aria o soffiare nell'unità Check O2 Plus. Effetti di altri gas L'unità Check O2 Plus è stata progettata per misurare due tipi differenti di miscele gassose: • Ossigeno, azoto e argon in uscita dai concentratori di ossigeno. • Ossigeno puro durante la modalità di verifica della calibratura. Ogni altra concentrazione o combinazione di gas determina misurazioni errate dell'ossigeno da parte dell'unità Check O2 Plus. 1176119-A • NON usare Check O2 Plus per misurare la concentrazione di ossigeno di un concentratore quando i relativi flussi sono inferiori a quelli ottimali specificati dal produttore del concentratore, cioè solitamente 4 LPM o meno su concentratori con flusso massimo di 10 LPM e 1 LPM o meno su concentratori con flusso massimo di 5 LPM. 73 5 Codici di errore 5.1 Codici di Errore Check O2 Plus è dotato di una modalità di autodiagnosi integrata nel software che serve a rilevare le letture errate esterne agli intervalli operativi normali. Codici, descrizioni e azioni raccomandate: • E01: misurazione dell'ossigeno esterna all'intervallo Alto (≥ • • • • 74 102,0% calcolata mediante algoritmo). Azione raccomandata: verificare che l'unità Check O2 Plus venga usata nella modalità corretta (modalità concentratore o modalità di verifica delle calibratura). Se il codice di errore riappare, eseguire una verifica della calibratura come indicato alla Sezione 4.3 del presente manuale. Se il codice di errore si ripete ancora, contattare l'Assistenza clienti. E02: misurazione dell'ossigeno esterna all'intervallo Basso (≤ -2,0% calcolata mediante algoritmo). Azione raccomandata: verificare che l'unità Check O2 Plus venga usata nella modalità corretta (modalità concentratore o modalità di verifica delle calibratura). Se il codice di errore riappare, eseguire una verifica della calibratura come indicato alla Sezione 4.3 del presente manuale. Se il codice di errore si ripete ancora, contattare l'Assistenza clienti. E03: memoria del dispositivo corrotta o mancante. Azione raccomandata: restituire l'unità Check O2 Plus al fabbricante per la riparazione in sede di fabbrica. E04: lettura del segnale instabile. Azione raccomandata: restituire l'unità Check O2 Plus al fabbricante per la riparazione in sede di fabbrica. E05: misurazione della pressione esterna all'intervallo Alto (≥50 PSI). Azione raccomandata: verificare la pressione con una fonte di gas di pressione nota. Se il codice di errore si ripete, contattare l'Assistenza clienti. • E06: fuori temperatura operativa Alta (≥40 SDgr C). Azione raccomandata: l'unità Check O2 Plus è troppo calda. Prima dell'uso, raffreddare il dispositivo fin quasi alla temperatura ambiente. • E07: fuori temperatura operativa Bassa (≤15 SDgr C). Azione raccomandata: l'unità Check O2 Plus è troppo fredda. Prima dell'uso, riscaldare il dispositivo fin quasi a temperatura ambiente. • E08: la funzione di autodiagnosi del dispositivo ha rilevato un errore. Azione raccomandata: rimuovere le batterie e sostituirle. Se il codice di errore si ripete, restituire l'unità Check O2 Plus al fabbricante per la riparazione in sede di fabbrica. 1176119-A Sostituzione delle batterie 6 Sostituzione delle batterie 6.1 Procedura di sostituzione delle batterie Sostituire le batterie quando si accende l'icona . L'icona resta accesa finché le batterie non vengono sostituite. Se il livello di potenza delle batterie è troppo basso, l'unità Check O2 Plus non si accende finchè queste non vengono sostituite. 1. 2. 3. 4. 5. Impiegando un cacciavite Phillips n.1 allentare la vite A dello sportello batterie B e rimuovere quest'ultimo. Rimuovere le batterie. Inserire le nuove batterie verificandone la corretta polarità. NON utilizzare batterie ricaricabili. Rimettere in sede lo sportello batterie e stringere la relativa vite. Se l'unità Check O2 Plus ancora non si accende, verificare che le batterie siano state installate correttamente e siano nuove. 1176119-A 75 7 Pulizia e manutenzione 7.1 Pulizia AVVERTENZA! Rischio di danneggiamento del prodotto Prestare la massima attenzione per evitare l'ingresso di fluidi all'interno di Check O2 Plus. – NON bagnare o immergere Check O2 Plus in alcun fluido. – NON sterilizzare l'unità Check O2 Plus mediante autoclave o esposizione a ossido di etilene. 7.2 Manutenzione • Sostituire le batterie con pile AA alcaline o al litio di alta qualità. NON utilizzare batterie ricaricabili. • Quando si prevede di non utilizzare l'unità per oltre 30 giorni, rimuovere le batterie per proteggere Check O2 Plus da possibili danni dovuti a fuoruscite di elettrolito. • Stoccare Check O2 Plus a temperature comprese fra -15°C e +60°C. Strofinare le superfici esterne dell'unità Check O2 Plus con un panno umido e sapone delicato per le mani o detersivo per stoviglie (pH 6-8). 76 1176119-A Dati tecnici Temperatura di stoccaggio: Pressione: Umidità: Requisiti di alimentazione: Durata delle batterie: Indicazione batteria debole: 8 Dati tecnici 8.1 Parametri tipici del prodotto OSSIGENO Intervallo di misurazione dell'ossigeno: (da un concentratore) Precisione di misurazione dell'ossigeno: Risoluzione di misurazione dell'ossigeno: 20,9–96% Dimensioni: ±1,5% su tutta la scala a temperatura costante e flusso ottimale* 0,1% di ossigeno Vedere Effetti del flusso basso, pagina 73 del presente manuale operativo per informazioni sugli effetti del flusso basso. FLUSSO Intervallo di misurazione del flusso: Precisione di misurazione del flusso: Risoluzione di misurazione del flusso: PRESSIONE Intervallo di misurazione della pressione: Precisione di misurazione della pressione: Risoluzione di misurazione della pressione: Tempo di risposta: Tempo di riscaldamento: Temperatura di esercizio: 1176119-A 0 - 10 LPM ±0,2 LPM Peso: CLASSIFICAZIONI: Protezione contro le scosse elettriche: Protezione contro l’acqua: Modalità operativa: Sterilizzazione: Miscela anestetica infiammabile: Specifiche dell'alimentazione: Da -15°C a +60°C 800 - 1000 mbar. 0–95% (senza condensa) 2 batterie alcaline AA (2 x 1,5 V). ≥1100 ore (16 500 cicli di lettura) Icona "Batt" (batteria debole) visualizzata sul display LCD (3.16" x 5.10" x 1.04") 80,3 mm x 129,5 mm x 26,4 mm 181 g apparecchiatura con alimentazione interna continua vedere 7.1 Pulizia , pagina 76. non utilizzare in presenza di miscele anestetiche infiammabili 1,8 - 3,2 V 32 mW 10mA 0,1 LPM PSI 0,5–50 kPA 3,4–344 ±0,5% ±0,5% 0,1 Da 0,1 a 199, 1 e da 200 a 344 ≤ 17 secondi < 1 secondo Da +15°C a +40°C 77 9 Garanzia commerciale 9.1 Garanzia commerciale Condizioni generali Invacare® garantisce l'assenza di difetti e la funzionalità delle proprie product. La garanzia copre tutti i guasti ed i difetti comprovabili derivanti da un tipo di costruzione errato, dall'impiego di materiali di cattiva qualità o da un'esecuzione inappropriata. I diritti di garanzia nei confronti di Invacare® possono essere fatti valere solo dal rivenditore e non dall'utente della product. Limitazioni di responsabilità La garanzia commerciale non copre la normale usura, danni derivanti da un trattamento inappropriato o danneggiamento intenzionale, da una manutenzione insufficiente e da un montaggio errato o dalla messa in servizio da parte dell'acquirente o di terzi, nonché difetti attribuibili a circostanze esterne. La garanzia decade se al prodotto sono apportate modifiche non previste e non eseguite dal rivenditore o in caso di utilizzo di parti di ricambio inadeguate. La garanzia di Invacare® non copre costi derivanti dall'eliminazione del difetto quali costi di spedizione e viaggio, costi di lavoro, spese ecc. Durata della garanzia La garanzia ha una durata di 24 mesi. Le parti soggette ad usura sono escluse dalla garanzia. Per ulteriori aspetti commerciali e di garanzia fare riferimento alla legislazione nazionale vigente. 78 1176119-A 6.1 Inhoudsopgave Deze handleiding dient te worden overhandigd aan de gebruiker van het product. Lees deze handleiding VÓÓR u het product gebruikt en bewaar hem voor eventuele raadplegingen in de toekomst. 1 Algemeen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 1.1 Symbolen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 1.2 Gebruiksdoel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 2 Systeemoverzicht . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.1 Beschrijving en werkingsprincipe . . . . . . . . . . . . . . . . 2.2 Identificatie van de bestanddelen . . . . . . . . . . . . . . . 2.3 Symboolgids . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.4 Beschrijving van onderdelen . . . . . . . . . . . . . . . . . . . 2.5 Meegeleverd . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 81 81 82 82 82 3 Veiligheid. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 3.1 Algemene richtlijnen. . . . . . . . . . . . . . . . . . . . . . . . . 83 3.2 Afvoeren . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 4 Gebruiksinstructies. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1 Zuurstof, stroming en druk meten . . . . . . . . . . . . . . 4.2 Drukeenheden veranderen . . . . . . . . . . . . . . . . . . . . 4.3 Procedure om de kalibratie te verifiëren . . . . . . . . . . 4.4 Factoren die een correcte Waarde beinvloeden . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Beïnvloeding door temperatuur . . . . . . . . . . . . . . . . Beïnvloeding door vochtigheid . . . . . . . . . . . . . . . . . Beïnvloeding door andere gassen . . . . . . . . . . . . . . . Beïnvloeding door lage stroming . . . . . . . . . . . . . . . . 86 86 86 86 86 86 86 87 87 5 Foutcodes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88 5.1 Foutcodes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88 6 De batterijen vervangen. . . . . . . . . . . . . . . . . . . . . . . . . 89 Batterijen vervangen . . . . . . . . . . . . . . . . . . . . . . . . 89 7 Reiniging en onderhoud . . . . . . . . . . . . . . . . . . . . . . . . . 90 7.1 Reiniging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 7.2 Onderhoud . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 8 Technische gegevens . . . . . . . . . . . . . . . . . . . . . . . . . . . 91 8.1 Algemene productparameters . . . . . . . . . . . . . . . . . . 91 9 Garantie . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 9.1 Garantie . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 Garantietermijn . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 1 Algemeen 1.1 Symbolen In deze gebruiksaanwijzing worden symbolen gebruikt die van toepassing zijn op gevaren of onveilige handelingen die kunnen leiden tot persoonlijk letsel of schade aan eigendommen. Zie de onderstaande informatie voor de definities van de symbolen. GEVAAR! – „Gevaar” geeft een op handen zijnde gevaarlijke situatie aan die, als deze niet wordt vermeden, de dood of ernstig letsel tot gevolg heeft. WAARSCHUWING! – Een waarschuwing duidt op een mogelijk gevaarlijke situatie die, indien deze niet wordt vermeden, kan leiden tot overlijden of ernstig letsel. LET OP! – „Let op” wijst op een mogelijk gevaarlijke situatie die, indien ze niet wordt voorkomen, kan leiden tot materiële schade of niet ernstig letsel, of beide. Geeft nuttige tips, adviezen en informatie voor efficiënt, probleemloos gebruik. 1.2 Gebruiksdoel WAARSCHUWING! – De CheckO2 Plus dient alleen voor het controleren van de zuurstofconcentrators. – Gebruik de CheckO2 Plus niet voor continue zuurstofbewaking. De Check O2 Plus mag alleen door opgeleid personeel worden gebruikt. De Check O2 Plus zuurstofanalysator meet de zuurstofconcentratie en -stroming met behoud van echografie en meet de druk met behulp van een piëzo-resistieve silicium druksensor. De Check O2 Plus zuurstofanalysator is een apparaat dat wordt gebruikt om de zuiverheid, de stroming en druk van zuurstof aan de uitlaat van een zuurstofconcentrator te meten. Het apparaat is niet bedoeld voor gebruik bij patiënten die voorgeschreven zuurstof krijgen, noch is het apparaat bedoeld om continu de zuurstoflevering aan een patiënt te meten of te bevestigen. De Check O2 Plus zuurstofanalysator is bedoeld om gebruikt te worden in een omgeving waar de zuurstofconcentrators worden onderhouden of gerepareerd. Dit omvat ziekenhuizen, verpleeghuizen, uitgebreide zorginstellingen, homes en centra waar ademhalingsapparaten worden onderhouden en gerepareerd. Dit product voldoet aan Richtlijn 93/42/EEG betreffende medische hulpmiddelen. De introductiedatum van dit product staat vermeld in de CE-verklaring van overeenstemming. 80 1176119-A Systeemoverzicht 2 Systeemoverzicht 2.2 Identificatie van de bestanddelen 2.1 Beschrijving en werkingsprincipe De Check O2 Plus is is een zuurstofanalysator die ontworpen is om de zuurstofconcentratie, stroming en uitlaatdruk van zuurstofconcentrators te controleren. De Check O2 Plus biedt door zijn geavanceerd ontwerp een ongeevenaarde prestatie en betrouwbaarheid, dat de volgende eigenschappen en werkingsvoordelen omvat. • • • • • • • • • • • Nauwkeurige zuurstofmetingen. Geen kalibratie ter plaatse vereist. U kunt de druk in PSI of kPa meten. Duurzaam, compact design. Groot, makkelijk afleesbare LCD-display (Liquid Crystal Display) Afgeschermde, versterkte inlaatpoort van monstergas. Lange batterijduur met 2 AA-batterijen. Automatische uitschakeling na 4 minuten. Indicatie voor batterij bijna leeg. Zelfdiagnose. Gemakkelijk schoon te maken. 1176119-A A LCD-scherm D Inlaat voor gasmonster B Modustoets E Uitlaat voor gasmonster C AAN-/UIT-toets F Batterijlade 81 2.3 Symboolgids 2.4 Beschrijving van onderdelen De volgende symbolen en veiligheidslabels kunnen op de Check O2 Plus teruggevonden worden: 3 1/2 Digit-display – De LCD stelt u in staat om de zuurstofconcentratie, gasstroming en gasdruk onmiddellijk af te lezen. De LCD geeft ook foutcodes weer, indien nodig. Geautoriseerde vertegenwoordiger in de Europese unie Aan/uit-toets Niet weggooien. Volg de plaatselijke richtlijnen inzake verwijdering. Modusknop Geevalueerd door ETL(Intertek Testing Laboratories) Batterij bijna leeg Fabrikant Liter per minuut Beschermingsklasse Pond per vierkante inch AAN/UIT-knop – Hiermee schakelt u het apparaat in of uit. De knop Mode – Hiermee schakelt u tussen het meten van de gasconcentratie die door een zuurstofconcentrators wordt geproduceerd en pure zuurstof (voor kalibratie). Indicator voor bijna lege batterij – Geeft aan dat de spanning van de batterij onder het normale bedrijfsniveau is. LPM – Brandt naast de stromingsmeting. (Niet afgebeeld tijdens de modus verificatie van de kalibratie). KPA – Geeft de druk weer in kilopascal. Latex free Kilopascal Serial number Procent Catalog number Uitlaat voor gasmonster Raadpleeg de bijgevoegde documenten Inlaat voor gasmonster PSI – Geeft de druk weer in ponden per vierkante inch. Het symbool “%” – Brandt naast de concentratie. Inlaat gasmonster – Wordt gebruikt om het gasmonster te ontvangen. Uitlaat gasmonster – Wordt gebruikt als uitlaat voor het gasmonster en activator voor het meten van de druk. Leidingwerk gasmonster – Wordt gebruikt om aan te sluiten op een bron voor het gasmonster. 2.5 Meegeleverd • Gebruiksaanwijzing • Leidingwerk voor gasmonster • Zacht deksel Gelijkstroom 82 1176119-A Veiligheid 3 Veiligheid 3.1 Algemene richtlijnen WAARSCHUWING! – Dit onderdeel bevat belangrijke informatie voor een veilige werking en gebruik van dit product. – GEBRUIK DIT PRODUCT OF DE BESCHIKBARE OPTIONELE APPARATUUR NIET VOORDAT U DEZE INSTRUCTIES EN HET EVENTUELE AANVULLENDE INSTRUCTIEMATERIAAL VOLLEDIG HEBT DOORGELEZEN EN BEGREPEN, ZOALS DE GEBRUIKERSHANDLEIDINGEN, SERVICEHANDLEIDINGEN OF INSTRUCTIEBLADEN DIE BIJ DIT PRODUCT OF DE OPTIONELE APPARATUUR WORDEN VERSTREKT. ALS U NIET IN STAAT BENT DE WAARSCHUWINGEN, AANDACHTSPUNTEN OF INSTRUCTIES TE BEGRIJPEN, NEEM DAN CONTACT OP MET EEN ZORGVERLENER, DEALER OF TECHNISCHE STAF VOORDAT U DIT APPARAAT GAAT GEBRUIKEN. ER KAN ANDERS LETSEL OF SCHADE OPTREDEN. WAARSCHUWING ACCESSOIRES – Invacare-producten zijn specifiek ontworpen en vervaardigd voor gebruik in combinatie met Invacare accessoires. Accessoires die door andere fabrikanten zijn ontworpen zijn niet getest door Invacare en worden niet aanbevolen voor gebruik met Invacare-producten. 1176119-A GEVAAR! TER VERMINDERING VAN HET RISICO OP BRANDWONDEN, ELEKTROCUTIE, BRAND OF PERSOONLIJK LETSEL – Niet voor gebruik tijdens het toepassen van anesthesie of om zuurstofconcentraties te meten die afkomstig zijn van een andere bron dan de conventionele zuurstofconcentrators. – Niet voor gebruik met inhalatiemiddelen. De CheckO2 Plus in een ontvlambare of explosieve atmosfeer gebruiken, kan tot brand of een explosie leiden. – Niet geschikt voor gebruik in de aanwezigheid van een ontvlambaar narcotisch mengsel. – Zuurstof versnelt de ontbranding. Rook niet tijdens het gebruik van de CheckO2 Plus. – Niet voor gebruik in een MRI-omgeving. 83 WAARSCHUWING! Als de CheckO2 Plus incorrect wordt gebruikt, dan kan dit leiden tot onjuiste zuurstofwaarden wat op zijn beurt kan leiden tot een incorrecte behandeling en/of letsel als aan de patiënt. Volg de procedures die in deze gebruikershandleiding werden omschreven. – Gebruikers moeten bekend zijn met de informatie van deze gebruikshandleiding. Het is van belang dat men zich strikt aan deze bedieningsinstructies houdt om een veilige en doeltreffende prestatie te garanderen. Dit product zal enkel zoals ontworpen werken, enkel als het bediend wordt in navolging met de bedieningsinstructies van de fabrikant. – Gebruik de CheckO2 Plus niet om de zuurstofconcentratie van een concentrator te meten wanneer deze aan een lagere waarde dan zijn optimale prestatie stroomt, zoals gespecificeerd door de fabrikant van de concentrator; in het algemeen is dit 4 LPM of minder voor concentrators die een maximale stroom van 10 LPM hebben en 1 LPM of minder voor concentrators die een maximale stroom van 5 LPM hebben. – Het gebruik van de CheckO2 Plus in de buurt van toestellen die elektrische velden opwekken kan afwijkende waarden tot gevolg hebben. 84 WAARSCHUWING! – Als de CheckO2 Plus wordt blootgesteld aan vloeistoffen, ten gevolge van morsen of onderdompeling, verwijder dan onmiddellijk de batterijen en laat het apparaat volledig drogen. Wanneer het apparaat droog is, vervang de batterijen en controleer of het apparaat correct werkt. – NIET DOEN: de CheckO2 Plus autoclaven of blootstellen aan hoge temperaturen (>65° C). – NIET DOEN: steriliseren met ethyldioxide. – NIET DOEN: de CheckO2 Plus blootstellen aan straling, vacuüm, stoom of bijtende chemicaliën. – NIET DOEN: de CheckO2 Plus blootstellen aan een druk groter dan 50 PSI. Als het apparaat wordt blootgesteld aan een druk hoger dan 50 PSI, dan kan dit leiden tot lekken die de prestatie op het vlak van de stroming- en drukwaarden beïnvloeden. – Reparatie(s) en/of aanpassing(en) aan de CheckO2 Plus, uitgevoerd door iemand anders dan een gekwalificeerde techische medewerker kan veroorzaken dat het product uitvalt of verminderde prestaties levert dan het product bedoeld is te leveren. 1176119-A Veiligheid LET OP! – Vervang de batterijen door hoogwaardige AA alkaline of lithium batterijen. Gebruik GEEN oplaadbare batterijen. – Als u het apparaat langer dan 30 dagen niet gebruikt, verwijder dan de batterijen om de CheckO2 Plus tegen batterijlekkage te beschermen. – Voorkomt dat u de CheckO2 Plus laat vallen, wat kan leiden tot schade die de prestatie negatief beïnvloed. Als u vermoedt dat het apparaat is beschadigd, voer dan de procedure om de kalibratie te verifiëren uit, zie 4.3 Procedure om de kalibratie te verifiëren , page 86 van deze handleiding. – Vermijd dat er vreemde stoffen in de CheckO2 Plus kunnen komen. – Gebruik de CheckO2 Plus NIET om een concentrator met een luchtbevochtiger te controleren. De vochtigheid van een luchtbevochtiger kan het apparaat beschadigen. – Controleer een concentrator NIET terwijl u de knop Mode ingedrukt houdt, anders zal de waarde onjuist zijn. – Als het apparaat in extreem warme of koude omstandigheden werd opgeslagen, laat het gas dan voldoende lang door de analysator stromen zodat de interne sensoren zich aan de temperatuur van de gasstroom kunnen aanpassen, of wacht tot de analysator op kamertemperatuur is voordat u deze gebruikt. 1176119-A 3.2 Afvoeren Dit product wordt geleverd door een milieubewuste fabrikant die zich houdt aan de richtlijn van de EU betreffende afgedankte elektrische en elektronische apparatuur (AEEA‐richtlijn) 2002/96/CE. Dit product kan stoffen bevatten die schadelijk zijn voor het milieu als ze afgevoerd worden naar plaatsen (stortplaatsen) die daar volgens de wet niet geschikt voor zijn. Wij hopen dat u voldoende milieubewust bent om dit product na de levensduur naar een afvalverwerkingsstation te brengen. De batterijen en printplaat mogen niet samen met het huishoudelijk afval worden weggegooid. 85 4 Gebruiksinstructies 1. 4.1 Zuurstof, stroming en druk meten 2. 3. Om de zuurstofconcentratie, stroming en druk van een gasmonster van een concentrator te meten: 1. 2. 3. 4. 5. 6. 7. Sluit het leidingwerk van het gasmonster op de inlaat van de Check O2 Plus aan. Bevestig het andere uiteinde van het leidingwerk op de zuurstofconcentrator. Laat het gas naar de Check O2 Plusstromen, aan een snelheid van 1-10 l per minuut (2 l per minuut wordt aanbevolen). Zorg dat de uitvoer van de concentrator stabiel is, volgens de aanbevelingen van de fabrikant van de concentrator. Schakel de Check O2 Plus in. Laat de zuurstofwaarden ongeveer 10 seconden stabiliseren voordat u de zuurstofconcentratie en stroming afleest. Onder druk te controleren, bedekt u de uitlaat van het gasmonster met een duim of vinger terwijl het gas aan het stromen is. Wacht 5 seconden, zodat de display de druk kan weergeven. Houd de knop Mode niet ingedrukt terwijl u een concentrator controleert, anders zal de waarde incorrect zijn. Met behulp van een kruiskopschroevendraaier maakt u de batterijklep los en verwijderd u de batterijklep. In het batterijvak kunt u de schakelaar veranderen. Plaats de batterijklep terug en draai de schroeven van de batterijklep opnieuw vast. 4.3 Procedure om de kalibratie te verifiëren Deze procedure is voorzien om de goede werking van de Check O2 Plus te controleren. De kalibratieprocedure uitvoeren: 1. 2. 3. 4. Schakel de Check O2 Plus in. Sluit een bron van zuivere zuurstof (≥99,95%) op de inlaat voor het gasmonster aan. Laat het gas aan 2-5 LPM in de UltraMaxO2 stromen. Zorg dat het gas dat naar de Check O2 Plus stroomt een stabiele temperatuur heeft. Houd de knop Mode ingedrukt. Terwijl u de knop Mode ingedrukt houdt, moet de zuurstofwaarde tussen 98,5 en 101,5% liggen. Als de waarde niet binnen dit bereik ligt, neem dan telefonisch contact op met de klantenservice. De modus Kalibratie verifiëren wordt aangeduid door "CAL" en "VER" zal op het scherm knipperen. 4.4 Factoren die een correcte Waarde beinvloeden Beïnvloeding door temperatuur 4.2 Drukeenheden veranderen De Check O2 Plus kan de druk in PSI of kPa meten. Standaard zal de Check O2 Plus in PSImeten. Veranderen naar kPa: De Check O2 Plus zal de temperatuur compenseren en zal binnen het bedrijfstemperatuurbereik volgens de specificaties werken. Echter, meten tijdens snelle temperatuurswijzigingen moet worden vermeden. Beïnvloeding door vochtigheid De Check O2 Plus beschikt over een vochtigheidssensor om de vochtigheid van het gas dat het apparaat binnenkomt te detecteren en 86 1176119-A Gebruiksinstructies te compenseren. Hoge vochtigheidswaarden (condensatie) kunnen de nauwkeurigheid en betrouwbaarheid van de Check O2 Plus beïnvloeden. Om mogelijke schade te voorkomen: • Vermijd gebruik in omgevingen met een relatieve vochtigheid die hoger is dan 95%. • NIET DOEN:dit apparaat in een ademhalingscircuit gebruiken. • NIET DOEN in de Check O2 Plus ademen of blazen. Beïnvloeding door andere gassen De Check O2 Plus is ontworpen om twee verschillende soorten gasmengelingen te meten: • Zuurstof, stikstof en argon uit zuurstofconcentrators. • Pure zuurstof tijdens de modus Kalibratie verificatie. Alle andere concentraties of combinaties van gassen zullen ervoor zorgen dat de Check O2 Plus de zuurstofconcentratie incorrect meet. 1176119-A Beïnvloeding door lage stroming Zuurstofconcentrators werken op het principe van het verwijderen van stikstofgas uit zuurstof, waardoor er een geconcentreerde zuurstof en argon overblijft aaneen specifieke verhouding. Dit werkingsprincipe kan worden gewijzigd wanneer concentrators worden ingesteld zodat ze aan de lage kant van hun operationele bereik stromen. Bij lage stroming geven ze een lage zuurstofconcentratie af, bijvoorbeeld 85% tot 91% voor andere redenen dan een hoog stikstofgehalte, mogelijk als gevolg van een toename aan argon. De Check O2 Plus vereist dat de verhouding van zuurstof tot argon constant blijft om een nauwkeurigheid van +/-1,5% te garanderen. • Gebruik de Check O2 Plus niet om de zuurstofconcentratie van een concentrator te meten wanneer deze aan een lagere waarde dan zijn optimale prestatie stroomt, zoals gespecificeerd door de fabrikant van de concentrator; in het algemeen is dit 4 LPM of minder voor concentrators die een maximale stroom van 10 LPM hebben en 1 LPM of minder voor concentrators die een maximale stroom van 5 LPM hebben. 87 5 Foutcodes 5.1 Foutcodes De Check O2 Plus beschikt over een zelfdiagnose die in de software is ingebouwd en die foute waarden – buiten het normale bedrijfsbereik – detecteert. De codes, beschrijvingen en aanbevolen acties zijn: • E01: Zuurstofmeting buiten het bereik Hi (≥ 102,0% berekend • • • • 88 door het algoritme). Aanbevolen actie: Controleer of de Check O2 Plus in de correcte modus wordt gebruikt (de modus Concentrator of Kalibratie verificatie). Als de foutcode zich herhaalt; voert u de kalibratie-verificatie uit volgens Deel 4.3 van deze handleiding. Als foutcode zich nogmaals herhaalt; moet u contact opnemen met de klantenservice. E02: Zuurstofmeting buiten het bereik Low (≤-2,0% berekend door het algoritme). Aanbevolen actie: Controleer of de Check O2 Plus in de correcte modus wordt gebruikt (de modus Concentrator of Kalibratie verificatie). Als de foutcode zich herhaalt; voert u de kalibratie-verificatie uit volgens Deel 4.3 van deze handleiding. Als foutcode zich nogmaals herhaalt; moet u contact opnemen met de klantenservice. E03: Geheugen van het apparaat beschadigd of ontbreekt. Aanbevolen actie: Stuur de Check O2 Plus terug naar de fabrikant voor reparatie. E04: Signaal niet stabiel. Aanbevolen actie: Stuur de Check O2 Plus terug naar de fabrikant voor reparatie. E05: Drukmeting buiten het bereik Hi (≥ 50 PSI). Aanbevolen actie: Controleer de druk met behulp van een gasbron met bekende druk. Als foutcode zich herhaalt; moet u contact opnemen met de klantenservice. • E06: Buiten bedrijfstemperatuur Hi (≥40¡Æ C). Aanbevolen actie: De Check O2 Plus is te warm, koel het apparaat af voordat u het gebruikt • E07: Buiten bedrijfstemperatuur Low (≤15¡Æ C). Aanbevolen actie: De Check O2 Plus is te koud, warm het apparaat op voordat u het gebruikt. • E08: Zelfdiagnose heeft een fout gevonden. Aanbevolen actie: Verwijder en vervang de batterijen. Stuur de Check O2 Plus terug naar de fabrikant voor reparatie. 1176119-A De batterijen vervangen 6 De batterijen vervangen 6.1 Batterijen vervangen Batterijen moeten worden vervangen wanneer het pictogram brandt. Dit pictogram blijft branden totdat de batterijen worden vervangen. Als de batterijspanning te laag is, zal de Check O2 Plus niet inschakelen totdat de batterijen werden vervangen. 1. 2. 3. 4. 5. Met behulp van een kruiskopschroevendraaier maakt u de batterijklep schroeven A los en verwijdert u de batterijklep B. Verwijder de batterijen. Plaats nieuwe batterijen, zorg dat de polariteit correct is. Gebruik GEEN oplaadbare batterijen. Plaats de batterijklep terug en draai de schroeven van de batterijklep opnieuw vast. Als de Check O2 Plus niet inschakelt, controleer dan of de batterijen correct werden geplaatst en of de batterijen vol zijn. 1176119-A 89 7 Reiniging en onderhoud 7.1 Reiniging LET OP! Risico op productbeschadiging Zorg dat er geen vloeistoffen in de Check O2 Plus kunnen komen. – NIET DOEN: de Check O2 Plus in vloeistoffen laten weken of onderdompelen. – NIET DOEN: de Check O2 Plus via autoclaaf of ethyloxide steriliseren. 7.2 Onderhoud • Vervang de batterijen door hoogwaardige AA alkaline of lithium batterijen. GEBRUIK GEEN oplaadbare batterijen. • Als u het apparaat langer dan 30 dagen niet gebruikt, verwijder dan de batterijen om de Check O2 Plus tegen batterijlekkage te beschermen. • Bewaar de Check O2 Plus tussen -15˚C en 60˚C (5˚F – 140˚F) Veeg de buitenkant van de Check O2 Plus met een vochtige doek en een milde handzeep of afwasmiddel (pH 6-8) schoon. 90 1176119-A Technische gegevens Druk: Vochtigheid: Voedingsvereisten: Levensduur batterij: Indicatie voor bijna lege batterij: Afmetingen: 8 Technische gegevens 8.1 Algemene productparameters ZUURSTOF Bereik van zuurstofmeting: (vanaf een concentrator) Nauwkeurigheid van de zuurstofmeting: Oplosvermogen van de zuurstofmeting: 20,9 - 96% 1,5% van de volledige schaal bij constante temperatuur en optimale stroming* 0,1% zuurstof Zie Beïnvloeding door lage stroming, page 87 van deze handleiding voor meer informatie over de effecten van een lage stroming. Stroming Bereik van stromingmeting: Nauwkeurigheid van de stromingmeting: Oplosvermogen van de stromingmeting: DRUK Bereik van drukmeting: Nauwkeurigheid van de drukmeting: Oplosvermogen van de drukmeting: Responstijd: Opwarmtijd: Bedrijfstemperatuur: Opslagtemperatuur: 1176119-A 0 - 10 LPM ±0,2 LPM Gewicht: CLASSIFICATIES: Bescherming tegen elektrische schok: Bescherming tegen water: Gebruikswijze: Sterilisatie: Ontvlambaar narcotisch mengsel: Voedingsspecificaties: 800 - 1000 mBars 0 tot 95% (niet condenserend) 2 AA alkalinebatterijen (2 x 1,5 Volt) > 1.100 uur (16.500 cycli). "Low Battery" pictogram op LCD 3,16" x 5,10" x 1,04" [80,3mm x 129,5mm x 26,4mm] 0,4 lbs (181 g) Intern gevoed apparaat Continu Zie 7.1 Reiniging , page 90. Niet geschikt voor gebruik in de aanwezigheid van een ontvlambaar narcotisch mengsel 1,8 - 3,2 V 32 mW 10mA 0,1 LPM PSI 0,5 - 50 ±0,5% KPA 3,4 - 344 ±0,5% 0,1 0,1 tot 199 1 van 200 tot 344 =< 17 seconden < 1 seconde 15˚C – 40˚C (59˚F-104˚F) -15˚C – 60˚C (5˚F-140˚F) 91 9 Garantie 9.1 Garantie Invacare® garandeert u een defectvrije en goed functionerende product. De garantie heeft betrekking op alle fouten en defecten die aantoonbaar als gevolg van een foutieve constructie, slechte materialen of een gebrekkige uitvoering zijn ontstaan. Garantieclaims jegens Invacare® kan alleen de verkooppartner en niet de eigenaar van het product indienen. Normale slijtage, de gevolgen van een ondeskundige behandeling of beschadiging, slecht onderhoud en foutieve montage of het gebruik door de koper of derden en gebreken die door buitenomstandigheden zijn veroorzaakt, vallen niet onder de garantie. De garantieplicht vervalt, als er niet voorziene en niet door de speciaalzaak uitgevoerde wijzigingen aan de product werden aangebracht of bij gebruik van ongeschikte vervangingsonderdelen. De garantie van Invacare® dekt geen kosten die ontstaan uit reparaties, zoals vracht- en reiskosten, loonkosten, onkosten, enz. Garantietermijn De garantietermijn bedraagt 24 maanden. Slijtagedelen zijn van de garantie uitgesloten. De termijnen en condities zijn onderdeel van de algemene richtlijnen en condities, specifiek naar de individuele landen waar dit produkt is verkocht. 92 1176119-A Notes Notes United Kingdom Invacare Limited • Pencoed Technology Park,Pencoed, Bridgend CF35 5HZ • Tel: (44) (0) 1656 776 222 • Fax: (44) (0) 1656 776 220 • www.invacare.co.uk • [email protected] Ireland Invacare Ireland Ltd • Unit 5 Seatown Business Campus • Seatown Road • Swords • County Dublin – Ireland • Tel : (353) 1 810 7084 • Fax: (353) 1 810 7085 • www.invacare.ie • [email protected] France Invacare Poirier SAS • Route de St Roch • F-37230 Fondettes • Tel: (33) (0)2 47 62 64 66 • Fax: (33) (0)2 47 42 12 24 • www.invacare.fr • [email protected] Switzerland Invacare AG • Benkenstrasse 260 • CH-4108 Witterswil • Tel.: (41) (0)61 487 70 80 • Fax.: (41) (0)61 487 70 81 • www.invacare.ch • [email protected] Deutschland Invacare GmbH • Alemannenstraße 10 • D-88316 Isny • Tel: (49) (0)75 62 7 00 0 • Fax: (49) (0)75 62 7 00 66 • www.invacare.de • [email protected] España Invacare SA • c/Areny s/n • Polígon Industrial de Celrà • E-17460 Celrà (Girona)Tel: (34) (0)972 49 32 00 • Fax: (34) (0)972 49 32 20 • www.invacare.es • [email protected] Belgium & Luxemburg Invacare nv • Autobaan 22 • B-8210 Loppem • Tel: (32) (0)50 83 10 10 • Fax: (32) (0)50 83 10 11 • [email protected] • www.invacare.be Nederland Invacare BV • Celsiusstraat 46 • NL-6716 BZ Ede • Tel: (31) (0)318 695 757 • Fax: (31) (0)318 695 758 • [email protected] • www.invacare.nl • [email protected] Österreich Invacare Austria GmbH • Herzog Odilostrasse 101 • A-5310 Mondsee • Tel: (43) 6232 5535 0 • Fax: (43) 6232 5535 4 • [email protected] • www.invacare.at Italia Invacare Mecc San s.r.l. • Via dei Pini 62 • I-36016 Thiene (VI) • Tel: (39) 0445 38 00 59 • Fax: (39) 0445 38 00 34 • [email protected] • www.invacare.it Authorized Representative QNET BV Hommerterweg 286 6436 AM Amstenrade The Netherlands Manufacturer Maxtec 6526 S. Cottonwood Street Salt Lake City, UT 84107 USA Tel: 801–266–5300 www.maxtecinc.com Distributed by: Invacare Corporation USA Canada One Invacare Way 570 Matheson Blvd. E Unit 8 Elyria, Ohio USA Mississauga, Ontario L4Z 4G4 44036–2125 905–890–8300 800–333–6900 www.invacare.com 1176119-A 2012-05-15 *1176119A*
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96

Invacare CE0123 Handleiding

Type
Handleiding
Deze handleiding is ook geschikt voor