Phanteks PH-ES614PTG de handleiding

Type
de handleiding

Deze handleiding is ook geschikt voor

USER’S MANUAL
3
INTRODUCTION
Congratulations on your purchase of the Phanteks Enthoo Series
Case and welcome to the Users Guide. Phanteks believes that
meaningful designs are created through the fusion of form and
function.
Caution
Please take a moment to carefully go through the installation guide. Phanteks will not
take responsibility for any damages incurred due to incorrect installation and incorrect
usage of this product. Thank you.
ENTHOO PRO TEMPERED GLASS EDITION
Continuing with the legacy of the Enthoo Series, the
Enthoo Pro is a full tower case with many rich features
implemented from the award-winning Enthoo Primo.
Full tempered glass side panel to showcase all your
components.
4
TABLE OF CONTENTS
1. SPECIFICATIONS ............................................................................................................................................................................................................... 5
2. EXPLODED VIEW ............................................................................................................................................................................................................... 6
3. ACCESSORIES .................................................................................................................................................................................................................... 8
4. BRACKETS .......................................................................................................................................................................................................................... 9
5. I/O PORTS ............................................................................................................................................................................................................................. 10
6. CONNECTIONS .................................................................................................................................................................................................................. 11
7. PANEL REMOVAL ............................................................................................................................................................................................................... 12
8. MOTHERBOARD INSTALLATION .................................................................................................................................................................................. 14
9. POWER SUPPLY COVER INSTALLATION .................................................................................................................................................................... 15
10. FILTERS REMOVAL .............................................................................................................................................................................................................. 18
11. FANS COMPATIBILITY ...................................................................................................................................................................................................... 19
12. SSD MOUNTING LOCATION ......................................................................................................................................................................................... 20
13. SSD/ODD INSTALLATION ............................................................................................................................................................................................... 21
14. HARD DRIVE INSTALLATION .......................................................................................................................................................................................... 22
15. WATERCOOLING INSTALLATION ................................................................................................................................................................................. 24
16. MORE RGB ......................................................................................................................................................................................................................... 28
17. PWM HUB INSTALLATION (OPTIONAL) .................................................................................................................................................................... 29
18. SUPPORT AND SERVICES ................................................................................................................................................................................................ 33
5
1. SPECIFICATIONS
CLEARANCE
Graphic card 347 mm
Without HDD cages 472 mm
CPU cooler 193 mm
Cable management 27 mm (39mm at PSU area)
Radiator Clearance 65mm to motherboard
Model number PH-ES614PTG
Warranty 5 Years
CASE SPECIFICATIONS
Dimension 235 mm x 535 mm x 550 mm (W x H x D)
Form Factor Full tower
Material(s)
ABS, Tempered Glass, Steel chassis
Motherboard support ATX, EATX, mATX, SSI EEB
Front I/O 2x USB 3.0, 2x USB 2.0, Mic, Headphone
LED Switch
Side window Yes, Tempered Glass panel
EXPANSION & DRIVE BAYS
Expansion slots 8
External 5.25” 3
Internal 3.5” 6 (2x 3HDD cages)
Internal 2.5” 11 (2x SSD Brackets)
COOLING 120 mm 140 mm 200mm
Front 2x(*2x included) 2x (1x included) 1x
Top 3x 3x 1x
Rear 1x 1x(1x included) -
Bottom 2x 1x -
HDD 2x - -
*PH-ES614PTG_SWT model only
LIQUID COOLING 120 mm radiator 140 mm radiator
Front Up to 240 -
Top Up to 360 Up to 420
Rear 120 140
Bottom Up to 240 140
6
2. EXPLODED VIEW
1. Chassis
2. Tempered Glass Side Panel
3. Right Side Panel
4. Front Panel
5. ODD Cover
6. Bottom Dust Filters
7. Top Panel
8. Phanteks Logo Plate
9. Front Mesh cover
10. Hard Drive Cage
11. SSD Bracket (2x)
12. PH-F140
13. Front dust lters
14. I/O Ports
15. Top Mesh cover with dust lter
16. PSU Cover
17. Reservoir Bracket
18. Bottom Feet
19. PH-F120 & PH-FF120RGBP*
1
2
4
6
6
7
8
9
11
12
13
14
15
3
17
10
16
19
5
18
*PH-ES614PTG_SWT model only
1. Chasis
2. Panel lateral izquierdo
3. Panel lateral derecho
4. Panel frontal
5. Cubierta de la unidad de disco óptico
6. Panel superior
7. Filtros de polvo inferiores
8. Placa con logotipo de Phanteks
9. Cubierta de malla frontal
10. Compartimento de disco duro
11. Soporte de unidad de estado sólido (2x)
12. PH-F140
13. Filtros para polvo delanteros
14. Puertos de E/S
15. Rejilla superior con ltro antipolvo
16. Tapa de la fuente de alimentación
17. Soporte del depósito
18. Pies inferiores
19. PH-F120 & PH-FF120RGBP*
7
1. Châssis
2. Panneau latéral gauche
3. Panneau latéral droit
4. Panneau frontal
5. Couvercle du ODD
6. Panneau supérieur
7. Filtres de poussière inférieurs
8. Plaque du logo Phanteks
9. Couvercle de grille du panneau frontal
10. Enclos du disque dur
11. Support SSD (2x)
12. PH-F140
13. Filtres à poussière avant
14. Ports E/S
15. Couvercle supérieur à maille avec ltre
antipoussière
16. Couvercle de l’unité d’alimentation
17. Support du réservoir
18. Pieds inférieurs
19. PH-F120 & PH-FF120RGBP*
1. Gehäuse
2. Linke Seitenblende
3. Rechte Seitenblende
4. Frontblende
5. Abdeckung für optisches Laufwerk
6. Deckblende
7. Untere Staublter
8. Phanteks-Logoplatte
9. Vordere Gitterabdeckung
10. Festplattenkäg
11. SSD-Halterung (2x)
12. PH-F140
13. Staublter an der Vorderseite
14. E/A-Anschlüsse
15. Obere Maschenabdeckung mit Staublter
16. Netzteilabdeckung
17. Reservoir-Halterung
18. Standfüße
19. PH-F120 & PH-FF120RGBP*
1. Telaio
2. Pannello laterale sinistro
3. Pannello laterale destro
4. Pannello frontale
5. Coperchio ODD
6. Pannello superiore
7. Filtri antipolvere inferiori
8. Piastra logo Phanteks
9. Copertura di rete frontale
10. Cage disco rigido
11. Staa SSD (2x)
12. PH-F140
13. Filtri antipolvere frontali
14. Porte I/O
15. Copertura superiore a maglia con ltro
antipolvere
16. Coperchio alimentazione
17. Staa serbatoio
18. Piedini inferiori
19. PH-F120 & PH-FF120RGBP*
1. Chassi
2. Painel Lateral Esquerdo
3. Painel Lateral Direito
4. Painel frontal
5. Cobertura ODD
6. Painel Superior
7. Filtros de Pó Inferiores
8. Placa de Logotipo Phanteks
9. Tampa de malha frontal
10. Berço do Disco Rígido
11. Suporte do SSD (2x)
12. PH-F140
13. Filtros frontais de poeira
14. Portas I/O (entrada/saída)
15. Tampa superior de malha com ltro de pó
16. Cobertura PSU
17. Suporte do Reservatório
18. Suportes inferiores
19. PH-F120 & PH-FF120RGBP*
1. Behuizing
2. Linker zijpaneel
3. Rechter zijpaneel
4. Voorpaneel
5. ODD deksel
6. Toppaneel
7. Bodem stolter
8. Phanteks logoplaat
9. Voorzijde mesh deksel
10. Harde schijf kooi
11. SSD beugel (2x)
12. PH-F140
13. Stof lter (voor)
14. Aansluitingen (voor)
15. Bovenpaneel mesh deksel met stolter
16. Voeding kap
17. Reservoir beugel
18. Bodem voet
19. PH-F120 & PH-FF120RGBP
*PH-ES614PTG_SWT model only
8
3. ACCESSORIES
8
3. ACCESSORIES
ITEM DESCRIPTION USE QTY ITEM DESCRIPTION USE QTY
Screw M3 x 5mm
Motherboard/
ODD/SSD
23 Screw 5 x 10KT Fan installation 12
Motherboard 2
Screw 6-32 x 6mm PSU, Brackets 5
CM6 #11
CM6 #5
HDD
Pumpbracket upgrade
12
Thumb Screws
6-32 x 6mm
PSU, Brackets,
HDD cages
3
Screw 6-32 x 31mm HDD fans 10 PWM6# x 6mm Hook-n-Loop Screw 2
5
ITEM DESCRIPTION USE QTY
150mm Zip Tie 10
188 x 10 x 1.8mm
Hook n Loop
(long)
1
110 x 10 x 1.8mm
Hook n Loop
(short)
1
Screw M4 x 8mm Reservoir
Reservoir bracket
8
KM6 #6
3
9
SSD Bracket (2x)
Support SSD
SSD-Halterung
Staa SSD
Suporte do SSD
Soporte de unidad de estado sólido
SSD beugel
Reservoir Bracket
Support du réservoir
Reservoir-Halterung
Staa serbatoio
Suporte do Reservatório
Soporte del depósito
Reservoir beugel
4. BRACKETS
8
3. ACCESSORIES
ITEM DESCRIPTION USE QTY ITEM DESCRIPTION USE QTY
Screw M3 x 5mm
Motherboard/
ODD/SSD
23 Screw 5 x 10KT Fan installation 12
Motherboard 2
Screw 6-32 x 6mm PSU, Brackets 5
CM6 #11
CM6 #5
HDD
Pumpbracket upgrade
12
Thumb Screws
6-32 x 6mm
PSU, Brackets,
HDD cages
3
Screw 6-32 x 31mm HDD fans 10 PWM6# x 6mm Hook-n-Loop Screw 2
5
ITEM DESCRIPTION USE QTY
150mm Zip Tie 10
188 x 10 x 1.8mm
Hook n Loop
(long)
1
110 x 10 x 1.8mm
Hook n Loop
(short)
1
Screw M4 x 8mm Reservoir
Reservoir bracket
8
KM6 #6
3
PSU Cover
Couvercle de l’unité d’alimentation
Netzteilabdeckung
Coperchio alimentazione
Cobertura PSU
Tapa de la fuente de alimentación
Voeding kap
10
5. I/O PORTS AND FRONT PANEL
FRONT VIEW TOP VIEW
Long Press: On/O
Short Press (<1sec): Choose LED Color (10 colors)
2 Sec Press: Choose Mode
Mode 1: Static Mode 2: Breathing Mode 3: Color Cycle
<1 sec
2 sec
HOLD
*RGB LED Control (6) Instructions:
** See page 11 for connection details.
** Voir page 11 pour les détails de connexion
** Einzelheiten zum Anschließen nden Sie auf Seite 11.
** Fare riferimento a pagina 11 per dettagli sul collegamento.
** Ver pagina 11 para detalhes de conexão.
** Consulte la página 11 para obtener información sobre la conexión.
** Zie pagina 11 voor aansluiting details
1
2
3
4
5
6*
7
1. USB 3.0
2. USB 2.0
3. Microphone
4. Headphone
5. Power Reset
6. LED Switch
7. Power Button/HDD LED
1. USB 3.0
2. USB 2.0
3. Microphone
4. Casque
5. Réinitialisation de l’alimentation
6. Interrupteur LED
7. Bouton d’alimentation
1. USB 3.0
2. USB 2.0
3. Mikrofon
4. Kopfhörer
5. Reset
6. LED-Schalter
7. Ein-/Austaste
1. USB 3.0
2. USB 2.0
3. Microfono
4. Cue
5. Ripristino alimentazione
6. Interruttore LED
7. Tasto d’alimentazione
1. USB 3.0
2. USB 2.0
3. Micrófono
4. Cascos
5. Resetear
6. Interruptor LED
7. Botón de alimentación
1. USB 3.0
2. USB 2.0
3. Microfone
4. Fone de ouvido
5. Redenição de Energia
6. Chave de LED
7. Botão de Alimentação
1. USB 3.0
2. USB 2.0
3. Microfoon
4. Hoofdtelefoon
5. Power Reset
6. LED bediening
7. Power knop
11
6. CONNECTIONS
RGB LED STRIP
Connects Phanteks’ multicolor LED strip /
Halos fan frames for interior lighting.
Power SW
HD
AUDIO
H.D.D LED
USB 3.0
12V SATA input
TO PSU
TO PHANTEKS
RGB LEDSTRIPS
RGB connector
(expansion)
TO MOTHERBOARD
12
7. PANEL REMOVAL
Unscrew the 2x thumb screws to remove the side panels.
Dévissez les vis à main pour enlever les panneaux latéraux.
Lösen Sie die 2 Rändelschrauben zum Entfernen der seitlichen Blenden.
Svitare le 2 viti per rimuovere i pannelli laterali.
Desaperte os 2 parafusos para remover os painéis laterais.
Desatornille los 2 tornillos de pulgar para retirar los paneles laterales.
Schroef 2 duimschroeven los om de zijpanelen te verwijderen.
Unscrew the 2x thumb screws to remove the glass panel.
Dévissez les vis à main pour enlever les panneaux latéraux.
Lösen Sie die 2 Rändelschrauben zum Entfernen der seitlichen Blenden.
Svitare le 2 viti per rimuovere i pannelli laterali.
Desaperte os 2 parafusos para remover os painéis laterais.
Desatornille los 2 tornillos de pulgar para retirar los paneles laterales.
Schroef 2 duimschroeven los om de zijpanelen te verwijderen.
2x
REAR
13
** To prevent damage to the panels, please follow the steps in order.
Step 1: Pull outward to remove the front panel.
Step 2: Pull up to remove the top panel.
** Pour éviter d’endommager les panneaux, veuillez suivre les étapes suivantes dans l’ordre.
Etape 1 : Tirez pour enlever le panneau frontal.
Etape 2 : Tirez vers le haut pour enlever le panneau supérieur.
** Bitte befolgen Sie zur Vermeidung von Schäden an den Blenden die Schritte der Reihe nach.
Schritt 1: Frontblende zum Entfernen nach außen ziehen.
Schritt 2: Deckblende zum Entfernen nach oben ziehen.
** Per evitare di danneggiare i pannelli, attenersi con ordine alle fasi.
Fase 1: tirare verso l’esterno per rimuovere il pannello frontale.
Fase 2: sollevare per rimuovere il pannello superiore.
** Para evitar danos aos painéis, por favor siga as instruções abaixo em ordem.
Etapa 1: Puxe para fora para remover o painel frontal.
Etapa 2: Puxe para cima para remover o painel superior.
** Para evitar dañar los paneles, siga los siguientes pasos en orden:
Paso 1: tire del panel frontal hacia afuera para quitarlo.
Paso 2: tire del panel superior hacia arriba para retirarlo.
** Om schade aan de panelen te voorkomen, volg dan de stappen in deze volgorde:
Stap 1: trek naar buiten om de voorpaneel te verwijderen
Stap 2: trek naar boven om de toppaneel te verwijderen
7. PANEL REMOVAL
** Use caution when removing front panel, Power LED wires are attached to front panel.
** Faites attention lorsque vous retirez le panneau frontal, les ls LED d’alimentation sont attachés au panneau frontal.
** Gehen Sie beim Entfernen der Frontblende vorsichtig vor, die Drähte der Betriebsanzeige-LED sind an der Frontblende befestigt.
** Usare cautela nella rimozione del pannello frontale, i cavi del LED d’alimentazione sono collegati al pannello frontale.
** Cuidado quando remover o painel frontal, os cabos do LED de energia são conectados ao painel frontal.
** Tenga cuidado cuando quite el panel frontal, ya que los cables LED de alimentación están sujetos al panel frontal.
** Wees voorzichtig bij het verwijderen van de voorpaneel, Power LED bedradingen zijn aan de voorpaneel bevestigd.
14
8. MOTHERBOARD INSTALLATION
Step 2: Install the motherboard with the provided M3 screws.
Etape 2 : Installez la carte mère avec les vis M3 fournies.
Schritt 2: Installieren Sie das Motherboard mit den mitgelieferten M3-Schrauben.
Fase 2: installare la scheda madre con le viti M3 fornite in dotazione.
Etapa 2: Instale a placa mãe com os parafusos M3 fornecidos.
Paso 2: instale la placa base con los tornillos M3 que se suministran.
Stap 2 : Installeer het moederbord met de meegeleverde M3- scrhoeven
Step 1: Stando screws are pre-installed for ATX. Extra stando required for E-ATX
Etape 1 : Des vis stando sont pré-installés pour ATX. Dautres vis stando sont nécessaire pour E-ATX
Schritt 1: Abstandhalterschrauben sind bei ATX vorinstalliert. Bei E-ATX sind zusätzliche Abstandhalter erforderlich
Fase 1: i pilastri a vite sono pre-installati per ATX. E-ATX necessita di pilastri a vite extra
Etapa 1: Os parafusos espaçadores são pré-instalado ao ATX. Espaçadores extra requeridos para E-ATX
Paso 1: se incluyen tornillos separadores preinstalados para ATX. Para E-ATX se necesitan más separadores
Stap 1: afstandschroeven zijn vooraf geinstalleerd voor ATX. Extra afstandschroeven zijn vereist voor E-ATX
Step 2
Step 1
15
1. Unscrew the thumb screws. 2. Pull out 3. lift up on the right side to remove cover
9. POWER SUPPLY INSTALLATION
1
1. Dévissez les vis de serrage. 2. Retirez. 3. Soulevez le côté droit pour retirer le couvercle
1. Lösen Sie die Fingerschrauben 2. Ziehen Sie die Netzteilabdeckung heraus.
3. Heben Sie die rechte Seite hoch, um die Abdeckung abzunehmen.
1. Svitare le viti ad alette. 2.Estrarre.
3. Sollevare la parte destra per rimuovere il coperchio
1. Solte os parafusos de aletas. 2. Retirar.
3. Levante o lado direito para remover a tampa
1. Desatornille los tornillos de apriete manual. 2. Retirar.
3. Levante desde el lado derecho para quitar la tapa
1. Draai de duimschroeven. 2. Trek 3. Til aan de rechterkant om te verwijderen
1. Remove PSU cover
18
1. Unscrew the thumb screws. 2. Pull out 3. lift up on the right side to remove cover
10. PSU COVER INSTALLATION
1
2
3
1. Dévissez les vis de serrage. 2. Retirez. 3. Soulevez le côté droit pour retirer le couvercle
1. Lösen Sie die Fingerschrauben 2. Ziehen Sie die Netzteilabdeckung heraus.
3. Heben Sie die rechte Seite hoch, um die Abdeckung abzunehmen.
1. Svitare le viti ad alette. 2.Estrarre.
3. Sollevare la parte destra per rimuovere il coperchio
1. Solte os parafusos de aletas. 2. Retirar.
3. Levante o lado direito para remover a tampa
1. Desatornille los tornillos de apriete manual. 2. Retirar.
3. Levante desde el lado derecho para quitar la tapa
1. Draai de duimschroeven. 2. Trek 3. Til aan de rechterkant om te verwijderen
16
9. POWER SUPPLY INSTALLATION
(4x)
Use the provided screws to secure the PSU in place.
Utilisez les vis fournies pour xer le bloc d’alimentation en place.
Befestigen Sie das Netzteil mit den mitgelieferten Schrauben.
Utilizzare le viti fornite per ssare la PSU in sito.
Use os parafusos para xar a Unidade de Proteção e de Comutação.
Utilice los tornillos suministrados para jar la fuente de alimentación en su posición.
Gebruik de meegeleverde schroeven om de voeding vast te zetten.
2. Install PSU
20
11. POWER SUPPLY INSTALLATION
(4x)
Use the provided screws to secure the PSU in place.
Utilisez les vis fournies pour xer le bloc d’alimentation en place.
Befestigen Sie das Netzteil mit den mitgelieferten Schrauben.
Utilizzare le viti fornite per ssare la PSU in sito.
Use os parafusos para xar a Unidade de Proteção e de Comutação.
Utilice los tornillos suministrados para jar la fuente de alimentación en su posición.
Gebruik de meegeleverde schroeven om de voeding vast te zetten.
REAR VIEW
REAR VIEW
20
11. POWER SUPPLY INSTALLATION
(4x)
Use the provided screws to secure the PSU in place.
Utilisez les vis fournies pour xer le bloc d’alimentation en place.
Befestigen Sie das Netzteil mit den mitgelieferten Schrauben.
Utilizzare le viti fornite per ssare la PSU in sito.
Use os parafusos para xar a Unidade de Proteção e de Comutação.
Utilice los tornillos suministrados para jar la fuente de alimentación en su posición.
Gebruik de meegeleverde schroeven om de voeding vast te zetten.
REAR VIEW
17
9. POWER SUPPLY INSTALLATION
1. Align to the three rubber grommets and slide in. 2. Use the provided thumb screws to lock in place.
2
1. Alignez les trois rondelles en caoutchouc et glissez po 2. Utilisez les vis de serrage prévus pour verrouiller en place.
1. Richten Sie die drei Gummidichtungen und schieben in. 2. Die Verwendung von Spannschrauben für die Verriege-
lung an Ort und Stelle zur Verfügung gestellt.
1. Allineare le tre guarnizioni in gomma e far scorrere dentro 2. L'uso di viti di bloccaggio per il bloccaggio in
posizione disponibile.
1. Alinhe os três selos de borracha e deslize dentro 2. A utilização de parafusos de aperto para o bloqueio no local
previsto.
1. Alinee los tres sellos de goma y deslice pulg 2. El uso de tornillos de jación para el bloqueo en su lugar siempre.
1. Lijn de drie rubberen afdichtingen en schuif inch 2. Het gebruik van klemschroeven voor de vergrendeling op zijn
plaats voorzien.
3. Install PSU cover
19
1. Align to the three rubber grommets and slide in. 2. Use the provided thumb screws to lock in place.
2
10. PSU COVER INSTALLATION
1
1. Alignez les trois rondelles en caoutchouc et glissez po 2. Utilisez les vis de serrage prévus pour verrouiller en place.
1. Richten Sie die drei Gummidichtungen und schieben in. 2. Die Verwendung von Spannschrauben für die Verriege-
lung an Ort und Stelle zur Verfügung gestellt.
1. Allineare le tre guarnizioni in gomma e far scorrere dentro 2. L'uso di viti di bloccaggio per il bloccaggio in
posizione disponibile.
1. Alinhe os três selos de borracha e deslize dentro 2. A utilização de parafusos de aperto para o bloqueio no local
previsto.
1. Alinee los tres sellos de goma y deslice pulg 2. El uso de tornillos de jación para el bloqueo en su lugar siempre.
1. Lijn de drie rubberen afdichtingen en schuif inch 2. Het gebruik van klemschroeven voor de vergrendeling op zijn
plaats voorzien.
18
10. FILTERS REMOVAL
To clean the dust lters, run slow moving water through the lters. Dry lters before reinstalling.
Pour nettoyer les ltres à poussière, faites couler de l’eau sur les ltres.
Séchez les ltres avant de réinstaller.
Reinigen Sie die Staublter, indem Sie sie unter langsam ießendem Wasser abspülen.
Filter vor Wiedereinbau trocknen.
Per pulire i ltri antipolvere, far correre lentamente l’acqua attraverso i ltri.
Asciugare i ltri prima di installarli di nuovo.
Para limpar os ltros de poeiras, passe água em movimento lento através dos ltros.
Seque os ltros antes de reinstalar.
Para limpiar los ltros de polvo, deje que caiga agua corriente lentamente sobre los ltros.
Seque los ltros antes de volverlos a colocar.
Laat langzaam stromend water door de lter lopen voor het reinigen van de lters. Droog de lters
voordat u het weer bevestigd.
To remove the bottom and front dust lters slide the lters out from the case.
Pour retirer les ltres à poussière inférieurs et avant, faites coulisser les ltres hors du boîtier.
Zum Entfernen der Staublter an der Unter- und Vorderseite schieben Sie die Filter aus dem Gehäuse
heraus
Per rimuovere i ltri antipolvere inferiori e anteriori, estrarre i ltri dal case.
Para remover os ltros de poeira inferior e frontal, deslize os ltros para fora da caixa.
Para quitar los ltros para polvo inferior y frontal, deslícelos extrayéndolos de la carcasa.
Schijf de voor- en bodem lters uit om deze te verwijderen.
19
11. FAN COMPATIBILITY
FAN COMPATIBILITY TABLE
200mm 140mm 120mm
Top
1
3 3
Bottom
1 2
Front
1 2
(1x included)
2
(2x included*)
Rear
(Top)
1
(1x included)
1
HDD Cages
2
*PH-ES614PTG_SWT model only
20
12. SSD MOUNTING LOCATION
Four mounting locations for the SSD brackets.
Installatie punten voor de SSD beugel.
Die SSD-Halterung
Emplacements de montage pour le support du disque SSD.
Posizioni di montaggio per la staa dell'SSD.
Posições de montagem para o suporte SSD.
Ubicaciones de instalación para el soporte de la unidad de estado
sólido.
Rear Side (optional SSD mounting
location)
Side SSD Mounting Location
21
13. SSD/ODD INSTALLATION
SSD INSTALLATION
Slide in the SSD and screw in from the side to lock in place.
Squeeze the two tabs in and push outward from inside the case.
ODD INSTALLATION
Align corner of bracket to the guide and drop down to lock.
Alignez le coin du support avec le guide et baissez-le pour verrouiller.
Richten Sie die Ecke der Halterung an der Führung aus und lassen
sie einrasten.
Allineare l’angolo della staa alla guida e calarla per bloccare.
Alinhe o canto do suporte ao guia e empurre para baixo para travar.
Alinee la esquina del soporte con la guía y empuje hacia abajo para
que quede sujeta.
Plaats de beugel langs de uitlijning en druk richting de pijl om te
bevestigen.
DROP N LOCK
Align and slide in.
Alignez et faites glisser.
Ausrichten und hineinschieben.
Allineare e far scorrere verso l’interno.
Alinhe e deslize para dentro.
Alinéela y deslícela.
Uitlijnen en inschuiven
Knijp de twee hendels in en duw deze van binnenuit de kast uit.
Faites entrer les deux pattes et poussez vers l'extérieur depuis l'intérieur du boîtier.
Drücken Sie die beiden Laschen hinein und drücken Sie sie innen im Gehäuse nach außen.
Premere le due linguette e spingere verso l'esterno dall'interno del case.
Comprima as duas guias e pressione para fora do compartimento.
Apriete las dos pestañas hacia adentro y empuje hacia afuera desde dentro de la carcasa.
Faites coulisser le disque SSD et vissez-le depuis le côté pour le
verrouiller dans son emplacement.
Schieben Sie die SSD ein und xieren Sie diese seitlich mit Schrauben.
Far scorre l’unità SSD e ssare le viti dal lato per bloccarla in posizione.
Deslize para dentro do SSD e parafuse do lado para travar no local.
Deslice la unidad de estado sólido hacia adentro y atorníllela desde el
lateral para bloquearla en su lugar.
Schuif de SSD in en monteer de schroeven via de zijkant om deze te
vergrendelen.
22
3.5” INSTALLATION
2.5” INSTALLATION
14. HARD DRIVE INSTALLATION
Align the tray to the HDD cage and slide in.
Alignez le plateau de l’enclos de DD et faites glisser.
Richten Sie das Fach am Festplattenkäg aus und schieben es hinein.
Allineare il cassetto alla gabbia HDD e farlo scorrere verso l’interno.
Alinhe a bandeja no berço do HDD e deslize.
Alinee la bandeja con el compartimento de la unidad del disco duro
y deslícela.
Leg de slede in positie in de HDD kooi en schuif deze in
Place hard drive into tray and push in the arms to lock.
Placez le disque dur dans le logement et poussez les bras pour le verrouiller.
Bringen Sie die Festplatten im Fach an und drücken die Arme zum Verriegeln hinein.
Collocare disco rigido nel cassetto e spingere i bracci verso l’interno per bloccare.
Coloque o disco rígido na bandeja e empurre os braços para travar.
Coloque el disco duro en la bandeja y pulse sobre los brazos para que quede sujeto.
Plaatst de harde schijf in de lade en duw de armen in voor vergrendeling.
Align the SSD onto the mounting holes and screw in.
Aligner le SSD avec les trous de montage et vissez.
Richten Sie die SSD an den Montagelöchern aus und befestigen die Schrauben.
Allineare l’unità ssd su i fori di installazione e ssare le viti.
Alinhe o SSD nos orifícios de xação e parafuse.
Alinee la unidad de estado sólido con los agujeros de montaje y atorníllela.
Lijn de SSD uit op de bevestigingsgaten en schroef de schroeven in.
23
14. HARD DRIVE INSTALLATION
Unscrew the thumbscrews to remove the cages.
Dévissez les vis à main pour enlever les cages.
Lösen Sie die Rändelschrauben zum Entfernen der Käge.
Svitare le viti per rimuovere le cage.
Desaperte os parafusos para remover os berços.
Desatornille los tornillos de pulgar para retirar los compartimentos.
Schroef de duimschroeven los om de kooien te verwijderen
REMOVING HDD CAGES
24
15. WATERCOOLING INSTALLATION
480mm
120mm
WATERCOOLING RADIATOR COMPATIBILITY
120mm, 140mm
240mm
120mm, 140mm
240mm
240mm, 280mm
360mm, 420mm
120mm, 140mm
25
Radiator Size
Taille de radiateur
Kühlkörpergröße
Dimensioni del radiatore
Tamanho do radiador
Tamaño del radiador
Radiator lengte
Front
Avant
Vorderseite
Parte frontale
Frente
Frontal
Voorkant
Rear
Arrière
Rückseite
Parte posteriore
Traseira
Posterior
Achterkant
Bottom
Dessous
Unterseite
Parte inferiore
Base
Inferior
Bodem
Top
Dessus
Oberseite
Parte superiore
Topo
Superior
Bovenkant
120mm
240mm
360mm
15. WATERCOOLING INSTALLATION
*Caution: Supported Radiator size and thickness varies depending on your setup.
*Avertissement : Les tailles de radiateur et les épaisseurs supportées varient en fonction de votre conguration.
*Achtung: Unterstützte Kühlkörpergröße und -dicke variieren je nach Aufbau.
* Attenzione: Le dimensioni e lo spessore supportati per il radiatore dipendono dalla congurazione.
*Atenção: O tamanho e espessura do Suporte do Radiador variam dependendo da conguração.
*Precaución: el grosor y el tamaño del radiador compatibles varían según la instalación que realice.
*Let op : Ondersteunde radiator grootte en dikte varieert afhankelijk van de opstelling.
120 MM FORM FACTOR RADIATORS
26
Radiator Size
Taille de radiateur
Kühlkörpergröße
Dimensioni del radiatore
Tamanho do radiador
Tamaño del radiador
Radiator lengte
Front
Avant
Vorderseite
Parte frontale
Frente
Frontal
Voorkant
Rear
Arrière
Rückseite
Parte posteriore
Traseira
Posterior
Achterkant
Bottom
Dessous
Unterseite
Parte inferiore
Base
Inferior
Bodem
Top
Dessus
Oberseite
Parte superiore
Topo
Superior
Bovenkant
140mm
280mm
420mm
*Caution: Supported Radiator size and thickness varies depending on your setup.
*Avertissement : Les tailles de radiateur et les épaisseurs supportées varient en fonction de votre conguration.
*Achtung: Unterstützte Kühlkörpergröße und -dicke variieren je nach Aufbau.
* Attenzione: Le dimensioni e lo spessore supportati per il radiatore dipendono dalla congurazione.
*Atenção: O tamanho e espessura do Suporte do Radiador variam dependendo da conguração.
*Precaución: el grosor y el tamaño del radiador compatibles varían según la instalación que realice.
*Let op : Ondersteunde radiator grootte en dikte varieert afhankelijk van de opstelling.
15. WATERCOOLING INSTALLATION
140 MM FORM FACTOR RADIATORS
27
15. WATERCOOLING INSTALLATION
RESERVOIR BRACKET INSTALLATION
Align the reservoir bracket to the mounting hole and screw into the top of the
reservoir bracket. Then use the provide 2x screw to lock the reservoir in place.
Aligner le support de réservoir à l'orice de montage et la visser dans la partie
supérieure du support de réservoir. Ensuite, utilisez le fournir vis 2x pour verrouiller le
réservoir en place.
Richten Sie die Halterung an der Reservoir Montageloch und Schraube in die Oberseite
des Behälters Halterung. Dann nutzen Sie die liefern 2x Schraube, um die Behälter zu
verriegeln.
Allineare il supporto serbatoio al foro di montaggio e avvitare la parte superiore del sup-
porto serbatoio. Quindi utilizzare il fornire vite 2x per bloccare il serbatoio in posizione.
Alinhe o suporte do reservatório para o furo de montagem e parafuso na parte superior
do suporte do reservatório. Em seguida, use o parafuso fornecer 2x para bloquear o
reservatório no lugar.
Alinear el soporte de depósito para el oricio de montaje y el tornillo en la parte superior
del soporte de depósito. A continuación, utilice el tornillo 2x proporcionar para bloquear
el depósito en su sitio.
Lijn het reservoir beugel aan het montagegat en schroef in de bovenkant van het
reservoir beugel. Maak dan gebruik van de meegeleverde 2x schroef om het reservoir te
vergrendelen.
30
17. WATERCOOLING INSTALLATION
RESERVOIR BRACKET INSTALLATION
Align the reservoir bracket to the mounting hole and screw into the top of the
reservoir bracket. Then use the provide 2x screw to lock the reservoir in place.
Aligner le support de réservoir à l'orice de montage et la visser dans la partie
supérieure du support de réservoir. Ensuite, utilisez le fournir vis 2x pour verrouiller le
réservoir en place.
Richten Sie die Halterung an der Reservoir Montageloch und Schraube in die Oberseite
des Behälters Halterung. Dann nutzen Sie die liefern 2x Schraube, um die Behälter zu
verriegeln.
Allineare il supporto serbatoio al foro di montaggio e avvitare la parte superiore del sup-
porto serbatoio. Quindi utilizzare il fornire vite 2x per bloccare il serbatoio in posizione.
Alinhe o suporte do reservatório para o furo de montagem e parafuso na parte superior
do suporte do reservatório. Em seguida, use o parafuso fornecer 2x para bloquear o
reservatório no lugar.
Alinear el soporte de depósito para el oricio de montaje y el tornillo en la parte superior
del soporte de depósito. A continuación, utilice el tornillo 2x proporcionar para bloquear
el depósito en su sitio.
Lijn het reservoir beugel aan het montagegat en schroef in de bovenkant van het
reservoir beugel. Maak dan gebruik van de meegeleverde 2x schroef om het reservoir te
vergrendelen.
28
16. MORE RGB
The RGB controller in the Enthoo PRO TG supports up to 5 meters of LED strips. This allows you to
expand your LED lighting throughout the entire case.
WE PROVIDE THE FOLLOWING RGB LED PRODUCTS:
- 2x 40cm magnetic RGB-LED strip
- Extension cable
- Motherboard RGB adapter
- High quality 3M adhesive
- Easy installation thanks to magnets
- High quality 3M adhesive included
- Easy installation thanks to magnets
- High quality 3M adhesive included
- Easy installation thanks to magnets
- High quality 3M adhesive included
- Also functions as an extension cable
- Allows you to synchronize with other RGB
products using the industry standard connector
- Illuminate your fan blades
- INTEGRATED MAGNETS
- QUALITY 3M ADHESIVE
- DURABLE WATERPROOF SILICON HOUSING
- EASY INSTALLATION WITH 1 ORIENTATION
CONNECTORS
- EXPANDABLE DAISY CHAIN CONNECTORS
COMBO SET (NOT INCLUDED)
PH-LEDKT_CMBO
400 MM EXTENSION (NOT INCLUDED)
PH-LEDKT_M4
1M LED STRIP (NOT INCLUDED)
PH-LEDKT_M1
2M LED STRIP (NOT INCLUDED)
PH-LEDKT_M2
RGB LED ADAPTER
PH-CB_RGB4P
HALOS FAN FRAMES
PH-FF120RGBP / PH-FF120RGBA / PH-FF140RGBP / FF140RGBA
29
17. PWM HUB INSTALLATION (OPTIONAL)
4-pin
(Motherboard CPU_Fan)
3-pin
(TO PWM HUB: FAN2, FAN3, FAN4, FAN5, FAN6)
3-pin connector
(FAN7, FAN8, FAN9, FAN10, FAN11, FAN12)
3-pin connector
(FAN7, FAN8, FAN9, FAN10, FAN11, FAN12)
SATA 12V POWER INPUT
(Power supply)
see important note
Y SPLITTER
PWM HUB
The PWM hub functions optimally when modulated by a PWM
signal from the motherboard, which will allow the greatest control
range. However, not all 4-pin motherboard connectors implement
the PWM signal modulation.
Connecting the 4-pin to CPU_FAN
For full PWM functionality, Phanteks’ PWM hub requires users to con-
nect the 4-pin connector to the “CPU_Fan” connector of the mother-
board, because all motherboard manufacturers implements a PWM
signal modulation on this connector. Connect the SATA 12V power to
power the PWM hub. Not all motherboards have their CPU_Fan con-
nector set on PWM signal modulation by default. Please consult your
motherboard documentation for this matter.
Connecting the 4-pin to other 4-pin header (besides the CPU_Fan)
Other 4-pin connectors can be found on modern motherboards be-
sides the “CPU_Fan” connector (e.g. “CPU_Fan2”, “CHA_Fan”, “OPT_Fan”),
however not all motherboard manufacturers implement a true PWM
signal modulation onto these connectors. These type of 4-pin connec-
tors modulate the RPM by voltage, which has a smaller control range
compared to modulation by true PWM signal.
The 12V SATA power cable can not be used to power the PWM hub if
connecting to these types of 4-pin connectors, due to the interference
with the RPM regulation by voltage (resulting in the fans running on
full RPM). The PWM hub will draw its power from the 4-pin connector,
which is limited to a total device consuming 30W in total.
Important Note:
1 motherboard connector can only read 1 RPM signal. Therefore, the motherboard
will only read the RPM signal from 1 device connected to Fan 1. The RPM form all
other devices will be regulated according to FAN 1. Y-splitter should not be connected
to FAN 1.
Please visit our website for multi-language instructions regarding PWM Hub at www.phanteks.com.
(Sold separately)
30
Le concentrateur à modulation de largeur d'impulsions (MLI) fonctionne de manière optimale quand il
est modulé par un signal MLI provenant de la carte mère, qui permet la plage de contrôle la plus impor-
tante. Cependant, tous les connecteurs de carte mère à 4 broches ne mettent pas en œuvre la modulation
de signal MLI.
Raccordement des 4 broches au CPU_VENTILATEUR
Pour une fonctionnalité MLI complète, le concentrateur MLI de Phanteks nécessite de raccorder le con-
necteur 4 broches au connecteur « CPU_Ventilateur » de la carte mère, car tous les fabricants de cartes
mères mettent en œuvre une modulation de signal MLI sur ce connecteur. Raccordez l'alimentation SATA
12V pour alimenter le concentrateur MLI. Toutes les cartes mères n'ont pas leur connecteur CPU_Ventila-
teur réglé sur la modulation de signal MLI par défaut. Veuillez consulter la documentation de votre carte
mère à ce sujet.
Raccordement du 4 broches à un autre connecteur 4 broches (indépendamment du CPU_Ventilateur)
D'autres connecteurs 4 broches se trouvent sur les cartes mères modernes indépendamment du connec-
teur « CPU_Ventilateur » (par exemple « CPU_Ventilateur2 », « CHA_Ventilateur », « OPT_Ventilateur
»), cependant tous les fabricants de cartes mères ne mettent pas en œuvre une modulation de signal MLI
réelle sur ces connecteurs. Ces types de connecteurs 4 broches modulent le régime par la tension, qui
présente une plage de contrôle plus petite comparée à une modulation par un signal MLI réel.
Le câble d'alimentation 12V SATA ne peut pas être utilisé pour alimenter le concentrateur MLI s'il est
raccordé à ces types de connecteurs 4 broches, en raison des interférences avec la régulation de régime
par tension (entraînant le fonctionnement des ventilateurs à plein régime). Le concentrateur MLI tire son
alimentation du connecteur 4 broches, qui est limité à une consommation totale des périphériques de
30 W.
Remarque importante :
1 connecteur de carte mère peut lire uniquement 1 signal de régime. Par conséquent, la carte mère lit
uniquement le signal de régime d'1 périphérique raccordé au Ventilateur 1. Le régime de tous les autres
périphériques sera régulé en fonction du VENTILATEUR 1. Un séparateur Y ne doit pas être raccordé au
VENTILATEUR 1.
Der PWM-Hub funktioniert bei Modulation durch ein PWM-Signal vom Motherboard einwandfrei, wodurch sich
ein größtmöglicher Kontrollbereich ergibt. Jedoch nicht alle 4-pol. Motherboard-Anschlüsse realisieren eine
PWM-Signalmodulation.
Verbindung mit 4-pol. CPU-Lüfteranschluss (CPU_Fan)
Für einen vollen PWM-Funktionsumfang ist es für den PWM-Hub von Phanteks erforderlich, dass der 4-pol. Stecker
mit dem CPU-Lüfteranschluss (“CPU_Fan”) am Motherboard verbunden wird, denn alle Motherboard-Hersteller
realisieren eine PWM-Signalmodulation an diesem Anschluss. Schließen Sie die 12-Volt-SATA-Stromversorgung an,
um den PWM-Hub mit Strom zu versorgen. Nicht bei allen Motherboards ist der CPU-Lüfteranschluss (CPU_Fan)
standardmäßig auf PWM-Signalmodulation gesetzt. Beziehen Sie sich hierzu bitte auf Ihre Motherboard-Doku-
mentation.
Verbindung des 4-pol. Anschlusses mit anderem 4-pol. Verteiler (außer CPU-Lüfteranschluss)
Neben dem CPU-Lüfteranschluss (“CPU_Fan”) benden sich weitere 4-pol. Anschlüsse auf modernen Mother-
boards (z. B. “CPU_Fan2”, “CHA_Fan”, “OPT_Fan”), aber nicht alle Motherboard-Hersteller realisieren eine echte
PWM-Signalmodulation an diesen Anschlüssen. Diese 4-pol. Anschlusstypen modulieren die Drehzahl mit der
Spannung, was zu einem kleineren Kontrollbereich im Vergleich zu einer Modulation mit einem echten PWM-Sig-
nal führt.
Das 12-Volt-SATA-Stromversorgungskabel kann bei Verbindung mit diesen 4-pol. Anschlusstypen nicht für eine
Stromversorgung des PWM-Hubs verwendet werden, denn die Spannung beeinträchtigt die Drehzahlregulierung
(sodass die Lüfter mit voller Drehzahl laufen). Der PWM-Hub bezieht seinen Strom vom 4-pol. Anschluss, sodass
ein Gerät insgesamt maximal 30 Watt verbraucht.
Wichtiger Hinweis:
1 Motherboard-Anschluss kann nur 1 Drehzahlsignal lesen. Demzufolge liest das Motherboard nur das Drehzahl-
signal von 1 Gerät, das mit Lüfter 1 (FAN 1) verbunden ist. Die Drehzahl aller anderen Geräte wird gemäß Lüfter 1
(FAN 1) reguliert. Ein Y-Splitter sollte nicht an Lüfter 1 (FAN 1) angeschlossen werden.
17. PWM HUB INSTALLATION
31
L’hub PWM funziona in modo ottimale quando è modulato da un segnale PWM dalla scheda madre,
che consentirà il massimo campo di regolazione. Tuttavia, non tutti i connettori a 4 pin della scheda
madre implementano la modulazione del segnale PWM.
Collegamento del connettore a 4 pin al connettore CPU_FAN
Per la completa funzionalità PWM, l’hub PWM Phanteks richiede il collegamento del connettore a 4 pin
al connettore “CPU_Fan della scheda madre, perché tutti i produttori di schede madre implementano
una modulazione del segnale PWM su questo connettore. Collegare l'alimentazione 12V SATA per
alimentare l'hub PWM. Non tutte le schede madre hanno, per impostazione predenita, il connettore
CPU_FAN impostato sulla modulazione del segnale PWM. Consultare la documentazione della scheda
madre in merito.
Collegamento del connettore a 4 pin ad altri connettori a 4 pin (oltre al connettore CPU_Fan)
Sulle schede madri odierne oltre al connettore "CPU_FAN" si possono trovare altri connettori a 4 pin
(ad esempio: "CPU_Fan2", "CHA_Fan", "OPT_Fan"), tuttavia non tutti i produttori di schede madre
implementano una vera modulazione del segnale PWM su questi connettori. Questi tipi di connettori a
4 pin modulano gli RPM per mezzo della tensione, che ha un campo di regolazione ridotto rispetto alla
reale modulazione del segnale PWM.
Il cavo di alimentazione 12V SATA non può essere utilizzato per alimentare l’hub PWM se si collegano
questi tipi di connettori a 4 pin, a causa dell'interferenza con la regolazione RPM per mezzo della
tensione (e di conseguenza le ventole funzionano a RPM massimo). L'hub PWM attingerà la sua alimen-
tazione dal connettore a 4 pin, che è limitata ad un consumo totale del dispositivo di 30W.
Nota importante:
1 connettore della scheda madre può leggere solo 1 segnale RPM. Pertanto, la scheda madre leggerà
solo il segnale RPM da 1 dispositivo collegato a Fan 1. Gli RPM di tutti gli altri dispositivi saranno
regolati in base a FAN 1. Lo splitter a Y non deve essere collegato a FAN 1.
O cubo PWM funciona de forma ideal quando modulados por um sinal PWM da placa mãe, que permitirá
uma faixa de controle maior. Entretanto, nem todos os conectores da placa mãe com 4-pin implementam a
modulação do sinal PWM.
Conectando 4-pin ao CPU_FAN
Para uma total funcionalidade PWM, o cubo PWM da Phanteks requer que os usuários conectem o conector
de 4-pin ao conector do "CPU_Fan" da placa mãe, porque todos os fabricantes de placa-mãe implementam
uma modulação de sinal PWM neste conector. Conecte a força SATA 12V ao cubo PWM. Nem todas as plac-
as-mãe têm seu conector CPU_Fan ajustado na modulação de sinal PWM de modo padrão. Por favor, consulte
a documentação de sua placa-mãe sobre este assunto.
Conectando o 4-pin a outro suporte de 4-pin (ao lado do CPU_Fan)
Outros conectores de 4-pin podem ser encontrados nas placas-mãe modernas ao lado do conector "CPU_Fan"
(por ex.: “CPU_Fan2”, “CHA_Fan”, “OPT_Fan”), entretanto nem todos os fabricantes de placas-mãe implemen-
tam uma modulação de sinal PWM real nestes conectores. Este tipo de conector de 4-pin modula as RPMs
pela tensão, que têm uma faixa de controle menor comparada com a modulação através do sinal PWM real.
O cabo de força 12V SATA não pode ser usado para ligar o cubo PWM, se a conexão é realizada com estes
tipos de conectores de 4-pin, devido à interferência com a regulagem das RPMs da tensão (resultando no
funcionamento dos ventiladores com as RPM totais). O cubo PWM irá dirigir sua força a partir do conector de
4-pin, que é limitado a um dispositivo total com consumo de 30W no total.
Observação importante:
1 conector da placa-mãe pode ler apenas 1 sinal de RPM. Entretanto, a placa-mãe irá ler apenas o sinal de
RPM de 1 dispositivo conectado ao Fan 1. A forma das RPM de todos os outros dispositivos será regulada de
acordo com o FAN 1. O divisor Y não deverá ser conectado ao FAN 1.
17. PWM HUB INSTALLATION
32
O cubo PWM funciona de forma ideal quando modulados por um sinal PWM da placa mãe, que permitirá
uma faixa de controle maior. Entretanto, nem todos os conectores da placa mãe com 4-pin implementam
a modulação do sinal PWM.
Conectando 4-pin ao CPU_FAN
Para uma total funcionalidade PWM, o cubo PWM da Phanteks requer que os usuários conectem o
conector de 4-pin ao conector do "CPU_Fan" da placa mãe, porque todos os fabricantes de placa-mãe
implementam uma modulação de sinal PWM neste conector. Conecte a força SATA 12V ao cubo PWM. Nem
todas as placas-mãe têm seu conector CPU_Fan ajustado na modulação de sinal PWM de modo padrão.
Por favor, consulte a documentação de sua placa-mãe sobre este assunto.
Conectando o 4-pin a outro suporte de 4-pin (ao lado do CPU_Fan)
Outros conectores de 4-pin podem ser encontrados nas placas-mãe modernas ao lado do conector
"CPU_Fan" (por ex.: “CPU_Fan2”, “CHA_Fan”, “OPT_Fan”), entretanto nem todos os fabricantes de
placas-mãe implementam uma modulação de sinal PWM real nestes conectores. Este tipo de conector de
4-pin modula as RPMs pela tensão, que têm uma faixa de controle menor comparada com a modulação
através do sinal PWM real.
O cabo de força 12V SATA não pode ser usado para ligar o cubo PWM, se a conexão é realizada com estes
tipos de conectores de 4-pin, devido à interferência com a regulagem das RPMs da tensão (resultando no
funcionamento dos ventiladores com as RPM totais). O cubo PWM irá dirigir sua força a partir do conector
de 4-pin, que é limitado a um dispositivo total com consumo de 30W no total.
Observação importante:
1 conector da placa-mãe pode ler apenas 1 sinal de RPM. Entretanto, a placa-mãe irá ler apenas o sinal de
RPM de 1 dispositivo conectado ao Fan 1. A forma das RPM de todos os outros dispositivos será regulada
de acordo com o FAN 1. O divisor Y não deverá ser conectado ao FAN 1.
17. PWM HUB INSTALLATION
De PWM hub functioneert optimaal wanneer bestuurd wordt door een PWM signaal vanuit het
moederbord. De PWM hub heeft dan de grootste regelbereik. Echter, niet alle moederborden besturen
alle 4-pin connectoren met een PWM-signaal.
De 4-pin aansluiten op CPU_FAN
Voor volledige PWM functie wordt vereist dat de 4-pin connector aangesloten wordt op de “CPU_Fan”
connector op het moederbord, omdat alle moederbord fabrikanten een PWM signaal implementeren
op deze connector. Sluit de SATA-12V kabel aan om de PWM hub te voorzien van stroom. Niet alle
moederborden hebben hun CPU_Fan connector standaard ingesteld op PWM modus. Raadpleeg
hiervoor uw moederbord handleiding.
De 4-pin aansluiten op andere 4-pin aansluitingen (naast de CPU_Fan)
Op moderne moederborden zijn vaak naast de CPU_Fan nog andere 4-pin connectoren te vinden (bijv.
“CPU_Fan2”, “CHA_Fan”, “OPT_Fan etc.) maar niet alle moederbord fabrikanten implementeren een
echte PWM-signaal op al deze aansluitpunten. Deze 4-pin aansluitingen regelen de RPM doormiddel
van voltage, dit geeft tevens een kleinere regelbereik in vergelijking met de besturing door echte
PWM-signaal.
De 12V SATA voedingskabel kan niet worden gebruikt wanneer de PWM hub aangesloten wordt op
deze type 4-pin aansluitpunten, vanwege interferentie met de RPM besturing doormiddel van voltage
(als gevolg zullen de ventilatoren onregelbaar zijn en op maximale RPM draaien). Zonder de 12V SATA
kabel zal de PWM hub zijn stroom halen uit de 4-pin connector, die beperkt is tot een totale verbruik
van 30W.
Belangrijke opmerking:
1 moederbord connector kan maar 1 RPM signaal lezen. Daarom zal het moederbord alleen een RPM
signaal lezen van 1 apparaat aangesloten op “Fan 1”. De RPM van alle andere aangesloten ventilatoren
worden geregeld op basis van het signaal op “Fan 1”. Een Y-splitter mag niet worden aangesloten op
“FAN 1”.
33
18. SERVICES AND SUPPORT
If you have any questions or concerns, please visit Phanteks’ web-
site for technical support. We consider customer support, satisfac-
tion and feedback an essential element of our overall marketing
eort. Please feel free to contact our support team. Thank you!
Si vous avez des questions ou des problèmes, veuillez vous rendre sur le site Internet de Phanteks
pour obtenir une assistance technique. Nous considérons le support, la satisfaction et le retour
d’informations de nos clients comme des éléments essentiels de notre démarche globale market-
ing. N’hésitez pas à contacter notre équipe support. Merci !
Bei Fragen oder anderen Anliegen besuchen Sie bitte den technischen Support auf der Website
von Phanteks. Für uns sind Betreuung, Zufriedenheit und Rückmeldungen von Kunden ein wich-
tiges Element bei all unseren Bemühungen im Marketingbereich. Unser Betreuungsteam steht
Ihnen gerne zur Verfügung. Vielen Dank!
In caso di dubbi o domande, visitare il sito Phanteks per il supporto tecnico. Consideriamo
l’assistenza clienti, la soddisfazione ed il feedback come elementi essenziali del nostro sforzo
complessivo di marketing. Non esitate a contattare il nostro team di supporto. Grazie!
Se você tiver quaisquer perguntas ou preocupações, por favor visite o website da Phanteks para
suporte técnico. Consideramos suporte ao cliente, satisfação e retorno um elemento essencial do
nosso esforço de marketing global. Sinta-se à vontade para entrar em contato com a nossa equipe
de suporte. Obrigado!
Si tiene alguna duda o experimenta algún problema, visite el sitio web de Phanteks para obtener
asistencia técnica. Para nosotros, la asistencia, la satisfacción y la opinión de los clientes forman
una parte esencial de nuestros esfuerzos de comercialización. No dude en ponerse en contacto con
nuestro equipo de asistencia. ¡Gracias!
Contact Us at / Contactez-nous à / Kontaktieren Sie uns unter / Con-
tattateci all’indirizzo / Contate-nos em / Contáctenos en/ Neem hier
contact met ons op:
USA:
International:
For Warranty Information, please visit Phanteks website.
Pour de plus amples informations concernant la garantie, veuillez visiter le site Internet de Phanteks.
Informationen zur Gewährleistung nden Sie auf der Website von Phanteks.
Visitare il sito Phanteks per informazioni sulla garanzia.
Para informações sobre a garantia, por favor visite o website da Phanteks.
Para obtener información acerca de la garantía, visite el sitio web de Phanteks.
www.phanteks.com
www.phanteksusa.com
www.phanteks.cn
Bezoek onze Phanteks' website voor vragen en technische ondersteuning. Klanten ondersteuning,
tevredenheid en feedback is voor ons een belangrijjk factor. Voel je vrij om met onze support team
contact op te nemen.
Bezoek onze Phanteks' website voor garantie voorwaarden
34
35
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35

Phanteks PH-ES614PTG de handleiding

Type
de handleiding
Deze handleiding is ook geschikt voor