- EN -
8
Unit installation (A, B)
The unit floats on the water. To keep it in position, the enclosed wire cables are fastened to the unit and either to the
bank or to the pond bottom.
Anchoring the unit at the bank (A): Shorten the two wire cables to the desired length. Form loops at the cable ends and
fasten with the cable clamps (3). Hook the cables into the eyebolts (4) at the skimmer housing by means of bayonet
hooks (1). Knock the two tent pegs (2) into the bank ground. Important: Adhere to the specified bracing angles (6) to
prevent the unit from moving. Set the unit in the water and hook the cables to the tent pegs (2) using the bayonet
hooks (1). Attention: Pull relieve the connection cable (8) and protect the power plug from moisture!
Anchoring the unit to the pond bottom (B): Shorten the two wire cables to the desired length (minimum 5 m). Form
loops at the cable ends and fasten with the cable clamps (3). Hook the cables into the eyebolts (4) at the skimmer
housing by means of bayonet hooks (1). For anchoring to the pond bottom, screw the enclosed threaded hooks (9)
including the dowel, for instance, into two sufficiently heavy stones. Hook both cables with bayonet hooks (1) in the
threaded hook (9), lower the stones to the bottom of the pond and set the unit on the water. Attention: Pull relieve the
connection cable (8) and protect the power plug from moisture!
Switching on, switching off (C)
Attention! Dangerous electrical voltage.
Possible consequences:
Death or severe injury.
Protective measures: Disconnect the power plug prior to reaching into the water and commencing work.
The unit switches on automatically when power connection is established.
Switching on: Plug the power plug (10) into the socket.
Switching off: Disconnect the power plug (10).
Cleaning (D-E)
Disconnect the power plug (10) prior to starting cleaning work!
Empty out the retaining basket (11) at regular intervals, clean with clear water, if necessary.
Clean the floating body (5) and the pump (18), as required, with clear water using a soft brush.
Pump removal (D-G)
Remove the retaining basket (11). Remove the brace (12) from the pump holder (13). Remove the Tradux wall
leadthrough (F) to be able to take out the power cable. For this purpose, only loosen the four M5 Allen screws, then
pull the entire unit out of the leadthrough tube (15). Remove the Allen screws as well as the rear (16) and front (17)
retaining plates together with the sealing insert (14). Pull the connection cable through the leadthrough tube (15). Pull
the pump (18) out of the pressure piece and remove from the floating body (5).
Important: When reassembling the Tradux wall leadthrough (F), ensure that the front (17) and rear (16) half shells of
the retaining plates are arranged at a 90° offset in relation to each other.
Storage/Over-wintering (H)
Take the unit out of operation when temperatures below zero are to be expected. Take the unit out of the water and
remove pump (18).
Clean pump (18) under running water, store immersed in a water filled container and frost protected. Do not immerse
the power plug in the water! Ensure that the storage place is inaccessible to children.
Store the floating body (5) in a dry and frost protected place.
Malfunction remedy
Check mains voltage
Clean, check supply lines
Pump does not deliver, insufficient delivered
quantity
Skimmer housing too high in the water
Skimmer flap jammed or sluggish
Clean skimmer flap bearing, ensure that skim-
mer flap operates freely
Insufficient cleaning effect
Skimmer flap jammed or sluggish
Clean skimmer flap bearing, ensure that skim-
mer flap operates freely
Pump switches off after a short running period
Water temperature too high
Note maximum water temperature of +35°C