Mettler Toledo pH electrode InPro4550VP Handleiding

Type
Handleiding
46 InPro 4550 VP pH electrode
InPro 4550 VP pH electrode © 04 / 16 Mettler-Toledo GmbH
52 002 400 Printed in Switzerland
nl
1 Inleiding ....................................................................... 47
2 Veiligheidsinstructies ..................................................... 47
3 Productbeschrving ....................................................... 47
4 Installatieeninbedrfstelling ........................................... 48
5 Bekabeling .................................................................... 48
6 Kalibratieenmeting ....................................................... 48
7 Onderhoud.................................................................... 48
8 Diagnostiek................................................................... 49
9 Probleemoplossing(trageresponstd,onvoldoende
gevoeligheid) ................................................................ 49
10 Afvoeren ....................................................................... 49
11 Garantie ....................................................................... 49
Inhoud
InPro
4550 VP
pH-elektrode
Gebruikershandleiding
InProenXerolytzngedeponeerdehandelsmerken
vanMettler-ToledoGmbHinZwitserland,deVS,
deEuropeseUnieenvfanderelanden.
nl Gebruikershandleiding
InPro 4550 VP pH electrode 47
© 04 / 16 Mettler-Toledo GmbH InPro 4550 VP pH electrode
Printed in Switzerland 52 002 400
nl
1 Inleiding
De METTLER TOLEDO-elektroden van het type
InPro
®
4550VP zijn onderhoudsarme, tempera-
tuurgecompenseerde gecombineerde pH-elektroden met
een polymeerelektrolyt (Xerolyt
®
Plus). Een ingebouwde
temperatuursensor(RTD)biedtautomatischecompensatie
van de slope van de elektrode, voor nauwkeurige
meetresultaten.
De InPro 4550VP-elektroden zn geschikt voor
pH-metingenin:
–emulsiesensuspensies;
–suldehoudendemedia;
–oplossingendiezwaremetalen(lood,kwik,zilverenz.)
bevatten;
–processenmet snelle drukschommelingen(binnenhet
aangegevenbereik);
–zwaarverontreinigdemedia.
DeInPro4550VP-elektrodenznnietgeschiktvoorsterili
-
satie-enautoclaafprocedures,processenmetsnelletem-
peratuurschommelingenoflevensmiddelentoepassingen.
Lees deze gebruiksaanwzing zorgvuldig door voordat
u het product in gebruik neemt, om een probleemloze
werking te garanderen. Mensen die met deze elektrode
werken,moetenaltdtoeganghebbentotdezealgemene
instructies.
2 Veiligheidsinstructies
DeInPro4550VP-elektrodenznuitsluitendbedoeldvoor
detoepassingendieinsectie1hierbovenznbeschreven.
Deelektrodenbestaanvooreendeeluitglasenmoeten
voorzichtig worden behandeld. Wanneer u de elektrode
moetreinigenofkalibrerenmetbehulpvanzureofalkalische
oplossingen,moetueenveiligheidsbrilenhandschoenen
dragen. B het werken met de elektrode zn de lokale
veiligheidsvoorschriftenvantoepassing.
Weadviserenomdeelektrodealleentegebruikenincombi
-
natiemetorigineleonderdelenvanMETTLERTOLEDO.Het
productmaguitsluitendwordenbediendenonderhouden
doorhiervooropgeleidpersoneeldatdegebruiksaanw
-
zingheeftgelezenendeinhoudervanheeftbegrepen.
3 Productbeschrving
Hetopschriftopelkeelektrodebevatdevolgendeinformatie:
METTLER TOLEDO Producent van de elektrode
InPro
®
4550 VP / xxx / SG Typeaanduiding/xxx=type
temperatuursensor
(Pt100/Pt1000)/
S G = h ul p e l e k t ro d e
combinationpH Typeelektrode
(gecombineerdepH)
pH0…14 pH-meetbereik
0…130°C Temperatuurbereikvoorbedrf
OrderNo.5200240X Bestelnummer
SEV14ATEX0168X Identicatieencerticaatnummer
IECExSEV14.0025X Identicatieencerticaatnummer
IS/I,II,III/1/ABCDEFG/T6 FM-goedkeuring
Seeinstructionmanual! Instructie(neemde
gebruiksaanwzinginacht)
Bovendieniselkeelektrodevoorzienvaneenserienummer
opdeinsteekkop,omidenticatiemogelktemaken.
48 InPro 4550 VP pH electrode
InPro 4550 VP pH electrode © 04 / 16 Mettler-Toledo GmbH
52 002 400 Printed in Switzerland
nl
4 Installatieeninbedrfstelling
1. Controleerdeelektrodebhetuitpakken,enopnieuw
voordat u gaat installeren, visueel op tekenen van
mechanische beschadiging van het glasmembraan,
de schacht en de connector. Meld eventuele
fouten of defecten onmiddellk aan uw erkende
METTLERTOLEDO-leverancier.
2. Verwderdebeschermdopenspoeldeelektrodeafmet
gedestilleerdofgede-ioniseerdwater.Gebruikuitsluitend
zachtetissuesomdeelektrodedroogtedeppen.Wrf
nietoverhetglasmembraan,aangezienditkanleiden
tottrageresponstdenvandeelektrode.
3. Elektroden met een droog glasmembraan moeten
vóórgebruikgedurendeenkeleurenwordengecondi
-
tioneerdineen3molKCl-oplossing.
4. Sluitaltddeoplossingsaarde(blauwekabel)aanop
detransmitter.
5. GebruikPTFE-tapeomdeNPT-draadaftedichten.
6. Gebruik zo mogelk de beschermhuls (bestel
-
nr.52401808).
5 Bekabeling
DeInPro4550VPisvoorzienvaneenVarioPin-connector.
Sluitdekabelopdeelektrodeaandoorhemindeelektrode
te steken en voorzichtig te draaien totdat de connector
vastklikt(groef).Schroefdedopmoervandekabelopde
elektrode totdat de verbinding stevig vastzit. De stekker
mag uitsluitend met de hand worden aangedraaid; er
mag geen gereedschapwordengebruikt.Raadpleeg het
instructieblad “De kabel voorbereiden voor aansluiting
op de transmitter” dat b de kabel werd geleverd,
voor bzonderheden over de exacte toewzing van
deafzonderlkedradenvandekabelaandepennenvande
VP-connector.
6 Kalibratie en meting
Voor InPro 4550VP-elektroden is tweepuntskalibratie
vereist. Verwder de beschermdop van de pH-elektrode
voordat u de kalibratie uitvoert. Dompel de elektrode
dan achtereenvolgens onder in twee verschillende
bufferoplossingen, elk met een bekende pH-waarde,
waarna de transmitter wordt gekalibreerd op basis van
dezebufferwaarden(bvoorbeeldbuffersmetpH4,01en
pH7,00).Neemdeinstructiesindegebruiksaanwzingb
detransmitterin acht.Herhaal dekalibratiewanneerdit
nodig is.
7 Onderhoud
–ElektrodenmetXerolyt
Plus-polymeerelektrolytkunnen
nietwordenbgevuld.
–Deelektrodenmogennooitdroogwordenopgeslagen.
–Gedurende de opslag moet de beschermdop zn
geplaatst en gevuld znmet Friscolyt™ofeen3mol
KCl-oplossing.
–Bewaar een elektrode nooit in gedestilleerd of gede-
ioniseerd water, aangezien dit te levensduur van de
elektrode bekort.
InPro 4550 VP pH electrode 49
© 04 / 16 Mettler-Toledo GmbH InPro 4550 VP pH electrode
Printed in Switzerland 52 002 400
nl
–Als de elektrode uitdroogt, moet u de elektrode vóór
gebruik gedurende 24 uur conditioneren in Friscolyt
(bestelnr.51340053voor250mlof51340054voor
63250ml).Nadeconditioneringmoeteropnieuween
kalibratiewordenuitgevoerd.
–Naelkebedrfscyclusmoetde puntvan deelektrode
wordengereinigdmetgede-ioniseerdwater.
Let op! Gebruik in geen geval reactiveringsoplossing van
METTLERTOLEDO(bestelnr.51319053),aangeziendie
waterstofuoride(HF)bevat,eenstofdieschadelkisvoor
hetXerolyt-referentiesysteem.
8 Diagnostiek
De elektroden zn uitgerust met een aardingsring waar-
meedetoestandvanhetmembraankanwordengecon-
troleerd. Als dit membraan (open junctie) verstopt raakt
ofalsdereferentieweerstandeenbepaaldewaardeover
-
schrdt (zie de gebruiksaanwzing b de transmitter),
moetdeelektrodewordenvervangen.InPro4550VP-elek
-
troden mogen in de regel niet worden gereinigd met
zure reinigingsoplossingen, zoals membraanreinigings-
oplossingen, reactiveringsoplossingen en dergelke.
Wanneer u echter zeer voorzichtig te werk gaat, is het
mogelk om het glasmembraan te reactiveren (zie
punt9verderop).
9 Probleemoplossing(trageresponstd,
onvoldoendegevoeligheid)
Let op! Het glasmembraan moet zeer voorzichtig met
eenHF-oplossingwordengedeptmetbehulpvaneenfn
penseel.Hierb moet u goed opletten datde oplossing
in aanraking komt met de titanium pen (metallische-
oplossingsaarde).Controleerbovendiendeconnector(VP)
vandeelektrodeopeventuelevochtsporen.Waarnodig
kuntudeconnectorgrondigreinigenmetgede-ioniseerd
waterofalcohol,envervolgenszorgvuldigdrogen.
10 Afvoeren
VoerInPro4550VP-elektrodenafovereenkomstigdelokale
ofnationalevoorschriften.
11 Garantie
Opproductiefouten,12maandennalevering.

Documenttranscriptie

nl Gebruikershandleiding nl 46 InPro 4550 VP pH electrode InPro 4550 VP pH-elektrode Gebruikershandleiding Inhoud 1 Inleiding........................................................................ 47 2 Veiligheidsinstructies...................................................... 47 3 Productbeschrijving........................................................ 47 4 Installatie en inbedrijfstelling............................................ 48 5 Bekabeling..................................................................... 48 6 Kalibratie en meting........................................................ 48 7 Onderhoud.................................................................... 48 8 Diagnostiek................................................................... 49 9 Probleemoplossing (trage responstijd, onvoldoende gevoeligheid)................................................................. 49 10 Afvoeren........................................................................ 49 11 Garantie........................................................................ 49 InPro en Xerolyt zijn gedeponeerde handelsmerken van Mettler-Toledo GmbH in Zwitserland, de VS, de Europese Unie en vijf andere landen. InPro 4550 VP pH electrode 52 002 400 © 04 / 16 Mettler-Toledo GmbH Printed in Switzerland InPro 4550 VP pH electrode 1 47 nl Inleiding De METTLER TOLEDO-elektroden van het type InPro® 4550 VP zijn onderhoudsarme, temperatuurgecompenseerde gecombineerde pH-elektroden met een polymeerelektrolyt (Xerolyt® Plus). Een ingebouwde temperatuursensor (RTD) biedt automatische compensatie van de slope van de elektrode, voor nauwkeurige meetresultaten. De InPro 4550 VP-elektroden zijn geschikt voor pH-metingen in: – emulsies en suspensies; – sulfidehoudende media; – oplossingen die zware metalen (lood, kwik, zilver enz.) bevatten; – processen met snelle drukschommelingen (binnen het aangegeven bereik); – zwaar verontreinigde media. De InPro 4550 VP-elektroden zijn niet geschikt voor sterilisatie- en autoclaafprocedures, processen met snelle temperatuurschommelingen of levensmiddelentoepassingen. Lees deze gebruiksaanwijzing zorgvuldig door voordat u het product in gebruik neemt, om een probleemloze werking te garanderen. Mensen die met deze elektrode werken, moeten altijd toegang hebben tot deze algemene instructies. 2 Veiligheidsinstructies De InPro 4550 VP-elektroden zijn uitsluitend bedoeld voor de toepassingen die in sectie 1 hierboven zijn beschreven. De elektroden bestaan voor een deel uit glas en moeten voorzichtig worden behandeld. Wanneer u de elektrode moet reinigen of kalibreren met behulp van zure of alkalische oplossingen, moet u een veiligheidsbril en handschoenen dragen. Bij het werken met de elektrode zijn de lokale veiligheidsvoorschriften van toepassing. We adviseren om de elektrode alleen te gebruiken in combinatie met originele onderdelen van METTLER TOLEDO. Het product mag uitsluitend worden bediend en onderhouden door hiervoor opgeleid personeel dat de gebruiksaanwijzing heeft gelezen en de inhoud ervan heeft begrepen. 3 Productbeschrijving Het opschrift op elke elektrode bevat de volgende informatie: METTLER TOLEDO InPro® 4550 VP / xxx / SG combination pH pH 0 … 14 0 … 130 °C Order No. 52 002 40X SEV14 ATEX 0168 X IECEx SEV 14.0025X IS / I, II, III/1 / ABCDEFG / T6 See instruction manual! Producent van de elektrode T ypeaanduiding / xxx = type temperatuursensor (Pt 100 / Pt 1000) / SG = hulpelektrode Type elektrode (gecombineerde pH) pH-meetbereik Temperatuurbereik voor bedrijf Bestelnummer Identificatie en certificaatnummer Identificatie en certificaatnummer FM-goedkeuring Instructie (neem de gebruiksaanwijzing in acht) Bovendien is elke elektrode voorzien van een serienummer op de insteekkop, om identificatie mogelijk te maken. © 04 / 16 Mettler-Toledo GmbH Printed in Switzerland InPro 4550 VP pH electrode 52 002 400 nl 4 48 InPro 4550 VP pH electrode Installatie en inbedrijfstelling 1. C  ontroleer de elektrode bij het uitpakken, en opnieuw voordat u gaat installeren, visueel op tekenen van mechanische beschadiging van het glasmembraan, de schacht en de connector. Meld eventuele fouten of defecten onmiddellijk aan uw erkende METTLER TOLEDO-leverancier. 2. Verwijder de beschermdop en spoel de elektrode af met gedestilleerd of gede-ioniseerd water. Gebruik uitsluitend zachte tissues om de elektrode droog te deppen. Wrijf niet over het glasmembraan, aangezien dit kan leiden tot trage responstijden van de elektrode. 3. Elektroden met een droog glasmembraan moeten vóór gebruik gedurende enkele uren worden geconditioneerd in een 3 mol KCl-oplossing. 4. Sluit altijd de oplossingsaarde (blauwe kabel) aan op de transmitter. 5. Gebruik PTFE-tape om de NPT-draad af te dichten. 6. Gebruik zo mogelijk de beschermhuls (bestelnr. 52 401 808). 5 Bekabeling De InPro 4550 VP is voorzien van een VarioPin-connector. Sluit de kabel op de elektrode aan door hem in de elektrode te steken en voorzichtig te draaien totdat de connector vastklikt (groef). Schroef de dopmoer van de kabel op de elektrode totdat de verbinding stevig vastzit. De stekker mag uitsluitend met de hand worden aangedraaid; er mag geen gereedschap worden gebruikt. Raadpleeg het instructieblad “De kabel voorbereiden voor aansluiting op de transmitter” dat bij de kabel werd geleverd, voor bijzonderheden over de exacte toewijzing van de afzonderlijke draden van de kabel aan de pennen van de VP-connector. 6 Kalibratie en meting Voor InPro 4550 VP-elektroden is tweepuntskalibratie vereist. Verwijder de beschermdop van de pH-elektrode voordat u de kalibratie uitvoert. Dompel de elektrode dan achtereenvolgens onder in twee verschillende bufferoplossingen, elk met een bekende pH-waarde, waarna de transmitter wordt gekalibreerd op basis van deze bufferwaarden (bijvoorbeeld buffers met pH 4,01 en pH 7,00). Neem de instructies in de gebruiksaanwijzing bij de transmitter in acht. Herhaal de kalibratie wanneer dit nodig is. 7 Onderhoud –E  lektroden met Xerolyt Plus-polymeerelektrolyt kunnen niet worden bijgevuld. – De elektroden mogen nooit droog worden opgeslagen. – Gedurende de opslag moet de beschermdop zijn geplaatst en gevuld zijn met Friscolyt™ of een 3 mol KCl-oplossing. – Bewaar een elektrode nooit in gedestilleerd of gedeioniseerd water, aangezien dit te levensduur van de elektrode bekort. InPro 4550 VP pH electrode 52 002 400 © 04 / 16 Mettler-Toledo GmbH Printed in Switzerland InPro 4550 VP pH electrode 49 nl –A  ls de elektrode uitdroogt, moet u de elektrode vóór gebruik gedurende 24 uur conditioneren in Friscolyt (bestelnr. 51 340 053 voor 250 ml of 51 340 054 voor 6 3 250 ml). Na de conditionering moet er opnieuw een kalibratie worden uitgevoerd. – Na elke bedrijfscyclus moet de punt van de elektrode worden gereinigd met gede-ioniseerd water. Let op! Gebruik in geen geval reactiveringsoplossing van METTLER TOLEDO (bestelnr. 51 319 053), aangezien die waterstoffluoride (HF) bevat, een stof die schadelijk is voor het Xerolyt-referentiesysteem. 8 Diagnostiek De elektroden zijn uitgerust met een aardingsring waarmee de toestand van het membraan kan worden gecontroleerd. Als dit membraan (open junctie) verstopt raakt of als de referentieweerstand een bepaalde waarde overschrijdt (zie de gebruiksaanwijzing bij de transmitter), moet de elektrode worden vervangen. InPro 4550 VP-elektroden mogen in de regel niet worden gereinigd met zure reinigingsoplossingen, zoals membraanreinigingsoplossingen, reactiveringsoplossingen en dergelijke. Wanneer u echter zeer voorzichtig te werk gaat, is het mogelijk om het glasmembraan te reactiveren (zie punt 9 verderop). 9 Probleemoplossing (trage responstijd, onvoldoende gevoeligheid) Let op! Het glasmembraan moet zeer voorzichtig met een HF-oplossing worden gedept met behulp van een fijn penseel. Hierbij moet u goed opletten dat de oplossing in aanraking komt met de titanium pen (metallischeoplossingsaarde). Controleer bovendien de connector (VP) van de elektrode op eventuele vochtsporen. Waar nodig kunt u de connector grondig reinigen met gede-ioniseerd water of alcohol, en vervolgens zorgvuldig drogen. 10 Afvoeren Voer InPro 4550 VP-elektroden af overeenkomstig de lokale of nationale voorschriften. 11 Garantie Op productiefouten, 12 maanden na levering. © 04 / 16 Mettler-Toledo GmbH Printed in Switzerland InPro 4550 VP pH electrode 52 002 400
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76

Mettler Toledo pH electrode InPro4550VP Handleiding

Type
Handleiding