INSTALLATION MANUAL Galvanic Isolator VDI-16 EN
1. Mounting location
Warning!
For safety purposes, the product should be installed in a heat-resistant environment. Avoid the presence of e.g. chemicals,
synthetic components, curtains or other textiles in the immediate vicinity of the product.
1.1. Install the galvanic isolator in a well ventilated area.
1.2. Keep a clear space of 10 cm around the product for ventilation.
1.3. The galvanic isolator must be mounted with its length vertical to allow for maximum cooling. Under normal circumstances, the
temperature increase of the heat sink is not more than 20°C. However the unit may become hot when conducting fault ground
current.
2. Installation
Warning!
The galvanic isolator must be wired into the green (safety) grounding conducting connection ahead of all grounding connections
to the vessel such that no ground connections on the vessel bypass the galvanic isolator making it ineffective.
2.1. Connections and safety features must be according to the locally applicable regulations.
2.2. Use electric cables of the appropriate size.
2.3. Wire the galvanic Isolator into the green (safety) grounding conducting connection as shown in fig. 1.
Figure 1: wiring diagram
INSTALLATIE MANUAL Galvanische Isolator VDI-16 NL
1. Locatie
Waarschuwing!
Dit product dient in een hittebestendige omgeving geïnstalleerd worden. Voorkom daarom de aanwezigheid van bijvoorbeeld
chemicaliën, kunststof onderdelen, gordijnen of ander textiel, etc. in de directe omgeving.
1.1. Installeer dit product in een droge, goed geventileerde ruimte.
1.2. Rondom het apparaat dient een ruimte van tenminste 10 cm te worden vrijgehouden voor koeling.
1.3. De galvanische isolator moet t. b. v. optimale koeling verticaal gemonteerd worden. Onder normale omstandigheden zal het
koellichaam niet meer dan 20°C warmer worden t. o. v. de omgeving. In geval van kortsluitstromen kan het apparaat heet
worden.
2. Installatie
Waarschuwing!
De galvanische isolator dient in de groen/gele aardraad verbinding gemonteerd te worden, vóór de aardverbinding naar het
schip.
2.1. Aansluitingen en beveiligingen moeten in overeenstemming met de plaatselijk geldende voorschriften worden uitgevoerd.
2.2. Gebruik kabel met de juiste aderdoorsnee.
2.3. Monteer de galvanische isolator in de groen/gele aardraad verbinding zoals aangegeven in fig. 1.
Figuur 1: Aansluit schema
Galvanic Isolator VDI-16 Waterproof (potted)
Maximum current 16 A
Peak current 1600 A / 20 ms
Connection 2 studs M6
Heat sink
Material Anodized aluminium
Protection category IP 67
Weight 1 kg
Dimensions (hxwxd) 60 x 120 x 200 mm
Galvanische Isolator VDI-16
Volledig waterdicht:
in epoxyhars gegoten
Netaansluiting tot tot 16 A
Piekstroom 1600 A / 20 ms
Aansluiting
2 bouten M6
(messing vernikkeld)
BEHUIZING
Materiaal
Geanodiseerd
aluminium
Beschermklasse IP 67
Gewicht 1 kg
Afmetingen (hxbxd) 60 x 120 x 200 mm
Victron Energy B.V.
De Paal 35
1351 JG ALMERE
The Netherlands
Phone: (+31) (0)36 535 97 00 Fax: (+31) (0)36 535 97 40 www.victronenergy.com e-mail: sales@victronenergy.com

Documenttranscriptie

INSTALLATION MANUAL Galvanic Isolator VDI-16 EN 1. Mounting location Warning! For safety purposes, the product should be installed in a heat-resistant environment. Avoid the presence of e.g. chemicals, synthetic components, curtains or other textiles in the immediate vicinity of the product. 1.1. 1.2. 1.3. Install the galvanic isolator in a well ventilated area. Keep a clear space of 10 cm around the product for ventilation. The galvanic isolator must be mounted with its length vertical to allow for maximum cooling. Under normal circumstances, the temperature increase of the heat sink is not more than 20°C. However the unit may become hot when conducting fault ground current. 2. Installation Warning! The galvanic isolator must be wired into the green (safety) grounding conducting connection ahead of all grounding connections to the vessel such that no ground connections on the vessel bypass the galvanic isolator making it ineffective. 2.1. 2.2. 2.3. Connections and safety features must be according to the locally applicable regulations. Use electric cables of the appropriate size. Wire the galvanic Isolator into the green (safety) grounding conducting connection as shown in fig. 1. Galvanic Isolator VDI-16 Waterproof (potted) Maximum current Peak current Connection Heat sink Material Protection category Weight 16 A 1600 A / 20 ms 2 studs M6 Anodized aluminium IP 67 1 kg Dimensions (hxwxd) 60 x 120 x 200 mm Figure 1: wiring diagram INSTALLATIE MANUAL Galvanische Isolator VDI-16 NL 1. Locatie Waarschuwing! Dit product dient in een hittebestendige omgeving geïnstalleerd worden. Voorkom daarom de aanwezigheid van bijvoorbeeld chemicaliën, kunststof onderdelen, gordijnen of ander textiel, etc. in de directe omgeving. 1.1. 1.2. 1.3. Installeer dit product in een droge, goed geventileerde ruimte. Rondom het apparaat dient een ruimte van tenminste 10 cm te worden vrijgehouden voor koeling. De galvanische isolator moet t. b. v. optimale koeling verticaal gemonteerd worden. Onder normale omstandigheden zal het koellichaam niet meer dan 20°C warmer worden t. o. v. de omgeving. In geval van kortsluitstromen kan het apparaat heet worden. 2. Installatie Waarschuwing! De galvanische isolator dient in de groen/gele aardraad verbinding gemonteerd te worden, vóór de aardverbinding naar het schip. 2.1. 2.2. 2.3. Aansluitingen en beveiligingen moeten in overeenstemming met de plaatselijk geldende voorschriften worden uitgevoerd. Gebruik kabel met de juiste aderdoorsnee. Monteer de galvanische isolator in de groen/gele aardraad verbinding zoals aangegeven in fig. 1. Galvanische Isolator VDI-16 Netaansluiting tot Piekstroom Aansluiting Volledig waterdicht: in epoxyhars gegoten tot 16 A 1600 A / 20 ms 2 bouten M6 (messing vernikkeld) BEHUIZING Materiaal Figuur 1: Aansluit schema Beschermklasse Gewicht Afmetingen (hxbxd) Geanodiseerd aluminium IP 67 1 kg 60 x 120 x 200 mm Victron Energy B.V. │ De Paal 35 │ 1351 JG ALMERE │ The Netherlands Phone: (+31) (0)36 535 97 00 │ Fax: (+31) (0)36 535 97 40 │ www.victronenergy.com │ e-mail: [email protected]
  • Page 1 1
  • Page 2 2
  • Page 3 3

Victron energy Galvanic Isolator (VDI-16) de handleiding

Categorie
Accessoires voor flatpanels
Type
de handleiding