ENGLISH
Intended use The Philips Avent Nipple Shield is intended
to cover and protect the nipples of lactating women
to support breastfeeding. The device is intended for
a single user.
Indications for use The Philips Avent Nipple Shield is
indicated for use when the mother has sore, sensitive,
cracked nipples or suers from nipple pain. It is also
indicated to help the baby develop better latch-on
behavior in case of oral anomalies or when the mother
has at/inverted nipples. Moreover, it can be used to
alleviate milk supply diculties when the baby is not
transferring the milk well, has an uncommon sucking
technique (i.e. weak sucking, small/preterm babies) or to
help the baby in coping with milk ow.
Contraindications There are no contraindications.
Side eects When using the device, undesirable
side eects that may occur are mastitis, cessation of
breastfeeding, infant thrush and poor infant weight gain.
If you or your baby experience any of these symptoms,
contact a healthcare professional or breastfeeding
specialist.
Important safety information
Read this important information carefully before you use
the product and save it for future reference.
Warning to avoid choking and swallowing
- Never leave the nipple shield and the hygiene case
unattended and keep out of reach of children.
- Inspect before each use. Throw away at the rst signs
of damage or weakness or after 2 months of usage.
Warning to avoid contamination and to ensure
hygiene
- Follow the instructions described in the Cleaning and
Disinfection sections.
Recommendations
- Use the product only in case of breastfeeding
problems as described in the Indications For Use.
- Recommended to be used with advice from health
care professional. If problems or pain occur, consult
your lactation consultant or physician.
- An electronic copy of these instructions can be found
at www.philips.com/support.
- Any serious incident that has occurred in relation to
this device should be reported to Philips via
www.philips.com/support and to the competent
authority of the Member State in which the user and/
or patient is established.
Before usage
Step 1 - Cleaning
Warning
Do not use abrasive cleaning agents or aggressive
chemicals or substances when you clean the nipple
shield. Clean the nipple shield and hygiene case before
rst use and immediately after each use.
Manual cleaning
1 Rinse with drinking-quality water for 10-15 seconds.
2 Wash in warm, drinking-quality water (approx. 35 °C)
with washing-up liquid, preferably without articial
fragrances or coloring.
3 Rinse with drinking-quality water for 10-15 seconds.
4 Dry with a clean cloth or leave to dry on a clean
surface.
Dishwasher cleaning
1 Place on top rack of the dishwasher.
2 Run standard program with common household
dishwasher detergent.
3 If not fully dry after dishwasher program, dry with a
clean cloth or leave to dry on a clean surface.
Step 2 - Disinfection
Warning
Disinfect before rst use and at least once a day. Clean
before disinfection.
Be careful: After disinfection, the nipple shields may be
very hot. The hygiene case and the water remaining in
the case may still be hot. To prevent burns, only use after
cooling down for 5 minutes.
Warnings to avoid contamination and to ensure
hygiene
If you use the hygiene case for disinfection:
- Clean the case before rst use.
- Use the correct water level, microwave power and
time. Not doing so can lead to reduced disinfection
and can damage the case or nipple shields.
- Only use the case provided.
Boiling
1 Clean as described under ‚Cleaning‘.
2 Boil the nipple shields in drinking-quality water for
5 minutes.
3 Leave to dry on a clean surface.
Microwave Alternatively, use only the hygiene case
provided according to the instructions below.
1 Clean the hygiene case (as described under
‘Cleaning’).
2 Add 25 ml of drinking-quality water to the case, up to
the indicated line (Fig. 1).
3 Place the nipple shield(s) in the hygiene case and
securely close the lid (Fig. 2).
4 Place the lled hygiene case in the microwave for
3 minutes at 750-1000 W (Fig. 3).
5 Let the hygiene case cool down for 5 minutes (Fig.4).
6 Drain water from the hygiene case (Fig.5).
7 Dry the nipple shield(s) with a clean cloth or leave to
dry on a clean surface.
Usage
Warning
Wash your hands and breasts thoroughly with soap and
water before you touch the nipple shields to prevent
contamination.
Applying the product Follow the instructions below
when placing the device on your breast:
1 Remove the cleaned and disinfected nipple shield
from the hygiene case.
2 Place drinking-quality water or breast milk on the
skin-facing side of the brim to help the shield stick to
your skin (Fig. 6).
3 Hold the shield at the base of the nipple area and
press the nipple cavity partially inside out, so that it
becomes half way inverted (Fig. 7).
4 Rotate the shield so that the baby can have nose and
chin contact with your breast skin (Fig. 8).
5 Center the shield over your nipple and slightly stretch
the wings of the shield as you stick the product onto
your breast (Fig. 9).
6 With the shield applied, you can now breastfeed as
normal.
Storing Store the clean nipple shield(s) in the hygiene
case or in a dry, clean container. Storing the nipple
shield(s) in an unclean or wet container could cause
contamination.
Disposal According to local regulations.
Explanation of symbols
The warning signs and symbols are essential to ensure
that you use this product safely and correctly and to
protect you and others from injury. Below you nd the
meaning of the warning signs and symbols on the label
and in the user manual.
This symbol indicates that the device
complies with European Medical Device
Directive 93/42/EEC requirements.
This symbol indicates the hygiene case is
microwave compatible.
This symbol indicates to ll the hygiene case
with water.
This symbol indicates to wait 5 minutes before
taking the hygiene case out of the microwave.
The 5 inside this symbol is the recycling code
used to identify the material from which the
hygiene case is made, which is polypropylene
(PP), to facilitate recycling or other reprocessing.
The Green Dot (‚Der Grüne Punkt‘ in German)
is the license symbol of a European network
of industry-funded systems for recycling the
packaging materials of consumer goods.
Technical specications
- Product type: Two type nipple shield size:
Small 15 mm; Medium: 21 mm.
- Materials: Silicone (nipple shield);
Polypropylene (hygiene case)
- Service life: 2 months
NEDERLANDS
Beoogd gebruik De Philips Avent-tepelbeschermer
bedekt en beschermt de tepels van vrouwen bij het
geven van borstvoeding. Het apparaat is bedoeld voor
een enkele gebruiker.
Indicaties voor gebruik De Philips Avent-
tepelbeschermer is geïndiceerd voor gebruik als de
moeder pijnlijke of gevoelige tepels heeft of last heeft
van tepelkloven. De tepelbeschermer is ook bedoeld
om borstvoeding gemakkelijker te maken bij mondelinge
afwijkingen van de baby of als de moeder platte/
omgekeerde tepels heeft. Het kan ook helpen problemen
met de melktoevoer te verhelpen wanneer de baby niet
goed drinkt of een ongebruikelijke drinktechniek heeft
(bijv. als de baby weinig zuigkracht heeft of voor kleine/
te vroeg geboren baby‘s), of om de baby te helpen
omgaan met de melkstroom.
Contra-indicaties Er zijn geen contra-indicaties.
Bijwerkingen Bij het gebruik van het apparaat kunnen
zich ongewenste bijwerkingen voordoen, zoals mastitis
(borstontsteking), beëindiging van de lactatie, spruw
en een slechte gewichtstoename van het kind. Neem
contact op met een gezondheidszorgprofessional of
lactatiedeskundige als u of uw baby een van deze
symptomen ervaart.
Belangrijke veiligheidsinformatie
Lees deze belangrijke informatie zorgvuldig door voordat
u het product gaat gebruiken en bewaar de informatie
om de aanwijzingen later opnieuw te kunnen raadplegen
Waarschuwing om verstikking en inslikken te
voorkomen
- Laat de tepelbeschermer en het hygiënische
bewaardoosje niet onbeheerd achter en houd het
buiten het bereik van kinderen.
- Inspecteer vóór elk gebruik. Gooi het product weg bij
de eerste tekenen van slijtage of beschadiging, of na
twee maanden gebruik.
Waarschuwing om besmetting te voorkomen en
hygiëne te waarborgen
- Volg de instructies die worden genoemd in de
hoofdstukken Reinigen en Desinfecteren.
750 – 1000W
3
5
8
6
9
25 ml/
0.9 .oz
1 2
5 min.
4
7
SCF153
Philips Consumer Lifestyle BV
Tussendiepen 4, 9206 AD Drachten, The Netherlands
www.philips.com/avent
Trademarks are the property of Koninklijke Philips N.V.
© 2019 Koninklijke Philips N.V.
All rights reserved.
3000.038.9742.1 (5/11/2019)
FSC
Nipple shield
Tepelbeschermer
3000_038_9742_2_DFU-Leaflet_37.5x25_v2.indd 1 05/11/2019 10:53