Buderus HR 200 Installation Instructions Manual

Type
Installation Instructions Manual

Deze handleiding is ook geschikt voor

1
HR 200 & HR 300
6 720 804 927 (2015/07)
Installation instructions
Swedish (Sv) ................................................. 2
English (En)................................................... 3
French (Fr) ................................................... 4
Italian (It) ...................................................... 5
Turkish (Tr) ................................................... 6
German (De) ................................................. 7
Estonian (Et).................................................. 8
NL (Be) ........................................................ 9
Greek (El).................................................... 10
Latvian (Lv) ................................................. 11
Lithuanian (Lt) ............................................. 12
Portuguese (pt) ........................................... 13
Slovak (Sk) ................................................. 14
Slovene (Sl) ................................................ 15
Czech (Cs)................................................... 16
Montážní návod
Netherlands (NL) ......................................... 17
Spanish (Es) ............................................... 18
Russian (Ru) ............................................... 19
Norwegian (No) ........................................... 20
Polish (Pl) ................................................... 21
2
HR 200 & HR 300 Sv
6 720 804 927 (2015/07)
Installation
Montera justeringsfötterna på varmvattenberedaren ([7]).
Placera varmvattenberedaren på ett plant underlag.
Montera svep/kappa på varmvattenberedaren.
Montera termometern på sidan av varmvattenberedaren ([8]).
Montera en automatisk avluftare (E41.F111) på
varmvattenberedarens inflöde alldeles vid beredaren ([3]).
Montera värmebärarrör till varmvattenberedarens inflöde på den automatiska
avluftaren ([3]). Montera därefter växelventilen (E21.Q21) på röret.
Anslut växelventilen till värmepumpens innedel.
Montera framledningsgivare (E11.T1) på växelventilens andra ingång. Framled-
ningsgivaren ska monteras minst en meter från växelventilen. Se systemlösning i
installatörshandboken för värmepumpen.
Montera värmebärarrör till varmvattenberedarens utflöde ([5]) och anslut till
värmepumpens innedel.
Anslut strömmatningen till växelventilen (E21.Q21) till kretskort i innedelens
ellåda. Se elschema i installatörshandboken för värmepumpen.
Placera varmvattengivaren (E41.T3) i insticksröret på utsidan av varmvattenbe-
redaren([4]). Givaren placeras cirka 600 mm (HR200) eller cirka 800 mm
(HR300) från botten av tanken.
Anslut varmvattengivaren till kretskort i innedelens ellåda. Se elschema i installa-
törshandboken för värmepumpen.
Anslut rör för varmvatten ([1]) och kallvatten ([6]).
Varmvattengivare T3
Om varmvattenberedare är ansluten och T3 är kopplad till systemet, autokvitteras
T3 vid uppstart.
Varmvattnet prioriteras och styrs av givaren T3 i varmvattenberedaren. När bereda-
ren värms kopplas värmedriften från värmepumpen tillfälligt bort via växelventilen.
När beredaren är uppvärmd fortsätter värmedriften från värmepumpen.
Bild 1 Varmvattenberedare (mm)
1 Varmvatten ut
2 Offeranod
3 Värmebärare in
4 Placering av givare
5 Värmebärare ut
6 Kallvatten in
7 Justeringsfötter
8 Termometer
9 Varmvattencirkulation G3/4"
H x D: HR 200 = 1340 x 600 mm, HR 300 = 1797 x 600 mm
VARNING: Kontrollera att golvet
håller för vikten 108 + 200 kg (HR 200)
eller 140 + 300 kg (HR 300).
Ha installatörshandboken för värmepumpen tillgänglig, då denna
innehåller aktuella systemlösningar och elscheman.
En automatisk avluftningsventil måste monteras då en varmvat-
tenberedare ansluts till systemet.
Ø 600
HR 200 = 1340, HR 300 = 1797
4
8
1
2
3
5
6
7
6720804927-01.1TL
9
3
HR 200 & HR 300 En
6 720 804 927 (2015/07)
Installation
Install the adjustment feet on the hot water cylinder ([7]).
Position the hot water cylinder on a level base.
Install the sweep/cover on the hot water cylinder.
Install the thermometer on the side of the hot water cylinder ([8]).
Install an automatic venting valve (E41.F111) on the inflow of the heat transfer
fluid ([3]).
Install a pipe for heat transfer fluid on the automatic venting valve ([3]) and
install the three-way valve (E21.Q21) on the pipe.
Connect the three-way valve to the indoor part of the heat pump.
Install the flow sensor (E11.T1) on the other inlet to the three-way valve. The flow
sensor must be positioned at least one metre from the three-way valve. Refer to
the system diagram in the installer manual for the Heat Pump.
Install pipes for the heat transfer fluid between the outlet for the transfer fluid
([5]) and the indoor part of the heat pump.
Connect the power supply for the three-way valve (E21.Q21) to the circuit board
in the electric box of the indoor unit. Refer to the electric diagram in the installer
manual for the Heat Pump.
Install the hot water sensor (E41.T3) in the dipstick pipe on the outside of the hot
water cylinder ([4]). Position the sensor approximately 600 mm (HR200) or
approximately 800 mm (HR300) from the bottom of the cylinder.
Connect the hot water sensor to the circuit board in the electric box of the indoor
unit. Refer to the electric diagram in the installer manual for the Heat Pump.
Connect domestic hot water ([1]) and domestic cold water ([6]).
Hot water sensor T3
If a hot water cylinder is installed and T3 is connected to the system, T3 is
automatically acknowledged at start-up.
Hot water is prioritised and controlled by the sensor T3 in the hot water cylinder.
While water is being heated in the cylinder, the heating system from the heat pump
is temporarily disconnected thorugh the three-way valve. The heating operation
from the heat pump continues when the water in the cylinder has reached the set
temperature.
Fig. 2 How water cylinder (mm)
1 Hot water, out
2 Sacrificial anode
3 Heat transfer fluid, in
4 Positioning sensor
5 Heat transfer fluid, out
6 Cold water, in
7 Adjustable feet
8 Thermometer
9 DHW circulation G3/4"
WARNING: Make sure that the floor can hold 108 + 200 kg (HR
200) or 140 + 300 kg (HR 300).
Keep the installer manual for the Heat Pump available as a
reference for the relevant system solutions and wiring diagrams.
An automatic venting valve must be installed when a hot water
cylinder is connected to the system.
Ø 600
HR 200 = 1340, HR 300 = 1797
4
8
1
2
3
5
6
7
6720804927-01.1TL
9
4
HR 200 & HR 300 Fr
6 720 804 927 (2015/07)
Installation
Installer les pieds de réglage sur le ballon ECS ([7]).
Placer le ballon ECS sur une surface plane.
Installer l'enveloppe/le capot sur le ballon ECS
Installer le thermomètre sur le côté du ballon ECS ([8]).
Installer un purgeur automatique (E41.F111) sur l'entrée du fluide caloporteur
près du chauffe-eau ([3]).
Installer un tuyau de fluide caloporteur sur le purgeur automatique placé à l'entrée
du fluide caloporteur. Installer le robinet inverseur (E21.Q21) sur le tuyau.
Raccorder le robinet inverseur à l'unité intérieure de la pompe à chaleur.
Installer la sonde de départ (E11.T1) sur l'autre entrée du robinet inverseur. La
sonde de départ doit être installée à au moins un mètre du robinet. Voir les solu-
tions systèmes dans le manuel d'installation.
Installer le tuyau de fluide caloporteur à la sortie de fluide caloporteur ([5]) et
raccorder ce tuyau à l'unité intérieure de la pompe à chaleur.
Brancher l'alimentation électrique du robinet inverseur (E21.Q21) à la carte élec-
tronique qui se trouve dans le boîtier électrique de l'unité intérieure de la pompe.
Voir le schéma électrique dans le manuel d'installation.
Installer la sonde ECS (E41.T3) dans le tube d‘entrée qui se place sur l‘extérieure
du ballon ECS ([4]). Placer la sonde à environ 600 mm (HR200) ou environ
800 mm (HR300) du fond du ballon ECS.
Raccordez la sonde ECS dans le boîtier électrique de l‘unité intérieure, sur la carte
à circuits imprimés. Voir le schéma électrique dans le manuel d'installation.
Raccordez l'eau chaude sanitaire ([1]) et l'eau froide ([6]).
Sonde ECS T3
Si un ballon ECS est raccordé et que T3 est connecté au système, T3 s'auto-valide
lors de la mise en route.
L'eau chaude sanitaire est prioritaire. Elle est commandée par la sonde T3 dans le
ballon ECS. Lorsque le ballon ECS chauffe, le mode chauffage est momentanément
suspendu au moyen d'une vanne d‘inversion. Une fois que l'eau du ballon ECS a
atteint la température souhaitée, la pompe à chaleur reprend le mode chauffage.
Fig. 3 Ballon ECS (mm)
1 Eau chaude sanitaire, sortie
2 Anode sacrificielle
3 Fluide caloporteur, entrée
4 Emplacement de la sonde
5 Fluide caloporteur, sortie
6 Eau froide, entrée
7 Pieds de réglage
8 Thermomètre
9 Bouclage ECS fil. 3/4"
AVERTISSEMENT : Vérifiez que le sol supporte une charge de
108 + 200 kg (HR 200) ou 140 + 300 kg (HR 300).
Aidez-vous du guide d'installation comme référence qui contient
les solutions système et les schémas électriques actuels.
Un purgeur automatique doit être raccordé du fait que le ballon
ECS est relié au système.
Ø 600
HR 200 = 1340, HR 300 = 1797
4
8
1
2
3
5
6
7
6720804927-01.1TL
9
5
HR 200 & HR 300 It
6 720 804 927 (2015/07)
Installazione
Montare i piedini di regolazione del bollitore ([7]).
Posare il bollitore su una superficie piana.
Montare il guscio/mantello del bollitore.
Montare il termometro sul lato del bollitore ([8]).
Montare uno sfiato automatico (E41.F111) sull'ingresso del fluido termovettore
del bollitore, nelle immediate vicinanze del bollitore ([3]).
Montare il tubo del fluido termovettore sullo sfiato automatico ([3]). Montare
quindi la valvola a 3 vie (E21.Q21) sul tubo.
Collegare la valvola a 3 vie all'unità interna della pompa di calore.
Montare la sonda di temperatura di mandata (E11.T1) sull'altro ingresso della val-
vola a 3 vie. La sonda di temperatura di mandata deve essere montata ad almeno
un metro di distanza dalla valvola a 3 vie. Vedere la soluzione di sistema le istru-
zione di installazione della pompa di calore.
Montare il tubo di ritorno del fluido termovettore in uscita dal bollitore ([5]) e
collegarlo all'unità interna della pompa di calore.
Effettuare il collegamento elettrico della valvola a 3 vie (E21.Q21) alla scheda
elettronica nell'armadietto elettrico dell'unità interna. Vedere lo schema elettrico
ne le istruzione di installazione della pompa di calore.
Posare la sonda di temperatura dell'acqua calda (E41.T3) nel tubo di innesto
all'esterno del bollitore ([4]). la sonda di temperatura deve essere posizionato
a circa 600 mm (HR200) o 800 mm (HR300) dal fondo del bollitore.
Collegare la sonda di temperatura dell'acqua calda alla scheda elettronica
nell'armadietto elettrico dell'unità interna. Vedere lo schema elettrico ne le istru-
zione di installazione della pompa di calore.
Collegare i tubi dell'acqua calda ([1]) e fredda ([6]).
Sonda di temperatura dell'acqua calda T3
Se nell'impianto è presente il bollitore e la sonda di temperatura T3 è collegata
all'impianto, la sonda di temperatura è abilitata automaticamente all'avviamento.
Ha sempre priorità la produzione di acqua calda, comandata dalla sonda di tempera-
tura T3 interna al bollitore. Durante l'approntamento sanitario, viene temporanea-
mente sospeso il riscaldamento tramite una valvola a 3 vie. Quando il bollitore ha
riscaldato l'acqua, viene ripristinato il riscaldamento da parte della pompa di calore.
Fig. 4 Caldaia (mm)
1 Uscita dell'acqua calda
2 Anodo sacrificale
3 Ingresso del fluido termovettore
4 Tubo di innesto (alloggiamento) per la sonda di temperatura
5 Uscita del fluido termovettore
6 Ingresso dell'acqua fredda
7 Piedini di regolazione
8 Termometro
9 Ricircolo acqua calda sanitaria G3/4"
AVVERTENZA: Accertarsi che il pavimento
abbia una portata di 108 + 200 kg (HR 200)
o 140 + 300 kg (HR 300).
Tenere a portata di mano le istruzione di installazione della pompa
di calore, che contiene le soluzioni di sistema e gli schemi elettrici
pertinenti.
Collegando un accumulatore produttore di acqua calda (detto in
seguito anche più brevemente bollitore) all'impianto è necessario
installare una valvola di sfiato automatica.
Ø 600
HR 200 = 1340, HR 300 = 1797
4
8
1
2
3
5
6
7
6720804927-01.1TL
9
6
HR 200 & HR 300 Tr
6 720 804 927 (2015/07)
Kurulum
Boylere ([7]) ayarlanabilir ayakları monte ediniz.
Boyleri düz zemine yerleştiriniz.
Boylerin üzerine koruma/izolasyon monte ediniz.
Termometreyi boylerin ([8]) yan tarafına monte ediniz.
Otomatik hava pürjörünü (E41.F111)
boylerin ([3]) iç akımınına, hemen ısıtıcının yanına monte ediniz.
Boylerin iç akım kısmında bulunan otomatik hava pürjörü ([3]) üstüne ısı
taşıyıcı boru monte ediniz. Daha sonra üç yollu vanayı (E21.Q21) boruya monte
ediniz.
Üç yollu vanayı ısı pompasının iç kısmına bağlayınız.
Akış sensörünü (E11.T1) üç yollu vananın diğer girişine monte ediniz. Akış
sensörü, üç yollu vananın en az bir metre uzağına monte edilmelidir. Isı pompası
kurulum kılavuzunda bulunan sistem çözümlerine bakınız.
Boylerin çıkış yoluna ([5]) ısı taşıyıcı boru monte edip, ısı pompasının iç
kısmına bağlayınız.
Üç yollu vananın (E21.Q21) güç kaynağını, iç kısımdaki elektrik kutusunun devre
kartına bağlayınız. Isı pompasının kurulum kılavuzunda elektrik şemasına bakınız.
Sıcak su sensörünü (E41.T3) boylerin dışındaki sensör yuvasına
yerleştiriniz.([4]). Sensör tankın alt kısmından yaklaşık 600 mm (HR200) yada
yaklaşık 800 mm (HR300) kadar üstüne yerleştirilir.
Sıcak su sensörünü iç kısımda bulunan elektrik kutusunun devre kartına
bağlayınız. Isı pompası kurulum kılavuzundaki elektrik şemasına bakınız.
Sıcak su ([1]) ve soğuk su ([6]) için boru bağlantılarını yapınız.
Sıcak su sensörü T3
Eğer boyler devreye alınmış ve T3 sisteme bağlı ise, çalıştırılma ile birlikte T3
otomatik olarak algılanır.
öncelik sıcak suya verilir ve boylerdeki T3 sensörü tarafından kontrol edilir. Boyler
ısınırken ısıtıcı üç yollu vana vasıtasıyla geçici olarak devre dışı bırakılır. Boyler
ısındıktan sonra ısıtma ısı pompasından devam eder.
Res. 5 Boyler (mm)
1 Sıcak su çıkış
2 Anod çübüğü
3 Isı taşıyıcı giriş
4 Sensör yuvası
5 Isı taşıyıcı çıkış
6 Soğuk su giriş
7 Ayarlanabilir ayaklar
8 Termometre
9 Sıcak kullanım suyu sirkülasyonu G3/4"
DİKKAT: Zeminin
108 + 200 kg (HR 200)
yada 140 + 300 kg (HR 300) ağırlığını kaldırabileceğini kontrol
edin.
Gerekli sistem çözümleri ve devre şemalarını içerdiği için, kurulum
kılavuzunu yanınızda hazır bulundurunuz.
Sisteme bir boyler ekleneceği için otomatik hava pürjörü monte
edilmelidir.
Ø 600
HR 200 = 1340, HR 300 = 1797
4
8
1
2
3
5
6
7
6720804927-01.1TL
9
7
HR 200 & HR 300 De
6 720 804 927 (2015/07)
Installation
Die Fußschrauben unter dem Warmwasserbereiter anbringen ([7]).
Den Warmwasserbereiter auf eine ebene Unterlage stellen.
Hülle/Haube an dem Warmwasserbereiter anbringen.
Das Thermometer an der Seite des Warmwasserbereiters anbringen ([8]).
Einen automatischen Entlüfter (E41.F111) auf dem Zulauf des Wärmeträgers,
direkt am Warmwasserbereiter anbringen ([3]).
Wärmeträgerrohr auf dem automatischen Entlüfter am Zulauf des Wärmeträgers
anbringen ([3]). Ventil wird in Rohrleitung eingebaut (E21.Q21).
Das Wechselventil am Innenteil der Wärmepumpe anbringen.
Vorlauffühler (E11.T1) am anderen Eingang des Wechselventils anbringen. Der
Vorlauffühler muss mindestens einen Meter vom Wechselventil entfernt ange-
bracht werden. Siehe Systemlösung im Handbuch für Installateure.
Das Wärmeträgerrohr am Rücklauf des Wärmeträgers anbringen ([5]) und am
Innenteil der Wärmepumpe anschließen.
Einspeisung an das Wechselventil (E21.Q21) und die Leiterplatte im Stromkas-
ten des Innenteils anschließen. Siehe elektrischer Schaltplan im Handbuch für
Installateure.
Den Warmwasserfühler (E41.T3) am Einsteckrohr an der Außenseite des Warm-
wasserbereiters platzieren. Den Fühler in einem Abstand von circa 600 mm
(HR200) oder circa 800 mm (HR300) vom Boden des Warmwasserbereiter plat-
zieren.
Den Warmwasserfühler an die Leiterplatte im Stromkasten des Innenteils
anschließen. Siehe elektrischer Schaltplan im Handbuch für Installateure.
Rohr für Warmwasser ([1]) und Kaltwasser ([6]) anschließen.
Warmwassertemperaturfühler T3
Ist der Warmwasserbereiter angeschlossen und T3 mit dem System verbunden, wird
T3 beim Anfahren automatische bestätigt.
Warmwasser ist vorrangig und vom Fühler T3 im Warmwasserbereiter gesteuert.
Wenn der Bereiter erwärmt ist, wird der Heizbetrieb vorübergehend über ein Wech-
selventil ausgeschaltet. Ist der Bereiter aufgewärmt, wird der Heizbetrieb von der
Wärmepumpe fortgetzt.
Bild 6 Warmwasserbereiter (mm)
1 Warmwasseraustritt
2 Opferanode
3 Vorlauf Heizwasser
4 Fühlerrohr
5 Rücklauf Heizwasser
6 Kaltwassereintritt
7 Fußschrauben
8 Thermometer
9 Warmwasserzirkulation G3/4"
WARNUNG: Überprüfen Sie bitte, ob der Fußboden ein Gewicht
von 108 + 200 kg (HR200) bzw. 140 + 300 kg (HR300) aushält.
Halten Sie das Handbuch für für die Wärmepumpe immer griffbe-
reit, da es aktuelle Systemlösungen und elektrische Schaltpläne
enthält.
Wenn ein Warmwasserbereiter an das System angeschlossen
wird, muss ein automatisches Entlüftungsventil angebracht wer-
den.
Ø 600
HR 200 = 1340, HR 300 = 1797
4
8
1
2
3
5
6
7
6720804927-01.1TL
9
8
HR 200 & HR 300 Et
6 720 804 927 (2015/07)
Paigaldamine
Kinnitada boileri alla reguleeritavad jalad ([7]).
Boiler tuleb paigutada ühetasasele pinnale.
Panna boileri külge ümbris/ülakate.
Kinnitada boileri küljele termomeeter ([8]).
Soojuskandja pealevoolule, otse boileri ([3]) juurde tuleb paigaldada
automaatne õhueraldi (E41.F111).
Automaatse õhueraldi külge tuleb soojuskandja pealevoolul kinnitada
soojuskandja toru ([3]). Torule tuleb paigaldada ventiil (E21.Q21).
Soojuspumba siseosale tuleb paigaldada ümberlülitusventiil.
Ümberlülitusventiili teisele sissevoolule tuleb paigaldada pealevooluandur
(E11.T1). Pealevooluandur peab paiknema ümberlülitusventiilist vähemalt ühe
meetri kaugusel. Vt süsteemi joonist, mis on esitatud paigaldusjuhendis.
Soojuskandja toru ([5]) tuleb panna soojuskandja tagasivoolukoha külge ja
ühendada soojuspumba siseosaga.
Ühendada siseosa elektrikilbis ümberlülitusventiili (E21.Q21) ja trükkplaadi
elektritoide. Vt elektriskeemi, mis on esitatud paigaldusjuhendis.
Paigutada sooja vee andur (E41.T3) sissepandava toru külge, mis paikneb boileri
välisküljel. Andur tuleb paigutada umbes 600 mm (HR200) või umbes 800 mm
(HR300) kõrgemale boileri põhjast.
Sooja vee andur tuleb siseosa elektrikilbis ühendada trükkplaadiga. Vt
elektriskeemi, mis on esitatud paigaldusjuhendis.
Ühendada sooja vee toru ([1]) ja külma vee toru ([6]).
Sooja vee temperatuuriandur T3
Kui boiler on ühendatud ja T3 süsteemiga tarkvaraliselt seotud, registreeritakse T3
käivitamisel automaatselt.
Vee soojendamine on prioriteetne ja seda juhitakse boileris oleva anduri T3 abil. Vee
soojendamise ajaks lülitatakse kütmine ümberlülitusventiili abil ajutiselt välja. Kui
vesi on boileris soojaks saanud, jätkab soojuspump kütmist.
Joon. 7 Boiler (mm)
1 Sooja vee väljavool
2 Kaitseanood
3 Soojuskandja pealevool
4 Anduri asukoht
5 Soojuskandja tagasivool
6 Külma vee sissevool
7 Reguleeritavad jalad
8 Termomeeter
9 Sooja vee ringlus G3/4"
HOIATUS. Palun üle kontrollida, kas põrand peab vastu raskusele
108 + 200 kg (HR200) või 140 + 300 kg (HR300).
Konkreetse süsteemi lahendust ja elektriskeeme sisaldav
soojuspumba kasutusjuhend tuleb alati hoida käepärast.
Kui süsteemiga on ühendatud boiler, tuleb paigaldada automaatne
õhueraldi.
Ø 600
HR 200 = 1340, HR 300 = 1797
4
8
1
2
3
5
6
7
6720804927-01.1TL
9
9
HR 200 & HR 300 Nl (Be)
6 720 804 927 (2015/07)
Installatie
Monteer de stelpoten onder de boiler ([7]).
Plaats de boiler op een vlakke ondergrond.
Monteer de mantel/kap op de boiler.
Monteer de thermometer op de zijkant van de boiler ([8]).
Breng een automatische ontluchter (E41.F111) aan op de aanvoer van de warm-
tedrager, direct op de boiler ([3]).
Breng de warmtedragerleiding op de automatische ontluchter op de aanvoer van
de warmtedrager aan ([3]). Het ventiel wordt in de leiding ingebouwd
(E21.Q21).
Monteer het omschakelventiel op het binnenwerk van de warmtepomp.
Monteer de aanvoertemperatuursensor (E11.T1) op de andere ingang van het
omschakelventiel. Monteer de aanvoertemperatuursensor op minimaal een me-
ter afstand van het omschakelventiel. Zie de systeemoplossing in het handboek
voor installateurs.
Breng de warmtedragerleiding op de retour van de warmtedrager aan ([5]) en
sluit deze aan op het binnenwerk van de warmtepomp.
Sluit de voeding aan op het omschakelventiel (E21.Q21) en de printplaat in de
aansluitkast van het binnenwerk. Zie het elektrische schakelschema in het hand-
boek voor installateurs.
Plaats de warmwatersensor (E41.T3) op de insteekbuis op de buitenzijde van de
boiler. Plaats de sensor op een afstand van ca. 600 mm (HR200) of ca. 800 mm
(HR300) van de bodem van de boiler.
Sluit de warmwatersensor aan op de printplaat in de aansluitkast van het binnen-
werk. Zie het elektrische schakelschema in het handboek voor installateurs.
Sluit de leidingen voor warmwater ([1]) en koud water ([6]) aan.
Warmwatertemperatuursensor T3
Wanneer de boiler is aangesloten en T3 is met het systeem verbonden, dan wordt T3
bij het starten automatisch bevestigd.
Warmwater wordt met voorrang en door sensor T3 in de boiler gestuurd. Wanneer de
boiler wordt opgewarmd, wordt het cv-bedrijf tijdelijk via een omschakelventiel uit-
geschakeld. Wanneer de boiler is opgewarmd, wordt het cv-bedrijf door de warmte-
pomp voortgezet.
Afb. 8 Boiler (mm)
1 Warmwateruitlaat
2 Opofferingsanode
3 Aanvoer cv-water
4 Sensorleiding
5 Retour cv-water
6 Ingang koud water
7 Instelbare stelpoten
8 Thermometer
9 Warmwatercirculatie G3/4"
WAARSCHUWING: controleer of de vloer een gewicht van
108 + 200 kg (HR200) resp. 140 + 300 kg (HR300) kan dragen.
Houd het handboek voor de warmtepomp altijd binnen handbereik,
omdat deze actuele systeem-oplossingen en elektrische schakel-
schema's bevat.
Breng een automatisch ontluchtingsventiel aan, wanneer een boi-
ler op het systeem wordt aange-sloten.
Ø 600
HR 200 = 1340, HR 300 = 1797
4
8
1
2
3
5
6
7
6720804927-01.1TL
9
10
HR 200 & HR 300 El
6 720 804 927 (2015/07)
Εγκατάσταση
Τοποθετήστε τα ποδαράκια στήριξης κάτω από το δοχείο ζεστού νερού χρήσης
([7]).
Τοποθετήστε το δοχείο ζεστού νερού χρήσης πάνω σε μια επίπεδη βάση.
Τοποθετήστε το περίβλημα/κάλυμμα στο δοχείο ζεστού νερού χρήσης.
Τοποθετήστε το θερμόμετρο στην πλευρά του δοχείου ζεστού νερού χρήσης
([8]).
Τοποθετήστε έναν αυτόματο εξαεριστήρα (E41.F111) στην παροχή του
εναλλάκτη, απευθείας στο δοχείο ζεστού νερού χρήσης ([3]).
Τοποθετήστε στην προσαγωγή του εναλλάκτη έναν αυτόματο εξαεριστήρα ([3]).
Η βαλβίδα τοποθετείται στη σωλήνωση (E21.Q21).
Τοποθετήστε την τρίοδη βαλβίδα στο εσωτερικό τμήμα της αντλίας θερμότητας.
Τοποθετήστε τον αισθητήρα προσαγωγής (E11.T1) στην άλλη είσοδο της τρίοδης
βαλβίδας. Ο αισθητήρας προσαγωγής πρέπει να τοποθετηθεί σε απόσταση
τουλάχιστον ενός μέτρου από την τρίοδη βαλβίδα. Βλέπε λύση συστήματος στο
εγχειρίδιο για εγκαταστάτες.
Τοποθετήστε το σωλήνα στην επιστροφή του εναλλάκτη ([5]) και συνδέστε τον
στο εσωτερικό τμήμα της αντλίας θερμότητας.
Συνδέστε την τροφοδοσία στην τρίοδη βαλβίδα (E21.Q21) και την πλακέτα του
κυκλώματος στον ηλεκτρικό πίνακα του εσωτερικού τμήματος. Βλέπε
ηλεκτρολογικό σχέδιο στο εγχειρίδιο για εγκαταστάτες.
Τοποθετήστε τον αισθητήρα ζεστού νερού (E41.T3) στο σωλήνα εισαγωγής στην
εξωτερική πλευρά του θερμοδοχείου. Τοποθετήστε τον αισθητήρα σε απόσταση
περίπου 600 mm (HR200) ή περίπου 800 mm (HR300) από τη βάση του
θερμοδοχείου.
Συνδέστε τον αισθητήρα ζεστού νερού με την πλακέτα του κυκλώματος στον πίνακα
ελέγχου του εσωτερικού τμήματος. Βλέπε ηλεκτρολογικό σχέδιο στο εγχειρίδιο για
εγκαταστάτες.
Συνδέστε το σωλήνα ζεστού νερού ([1]) και κρύου νερού ([6]).
Αισθητήρας θερμοκρασίας ζεστού νερού χρήσης T3
Όταν το δοχείο ζεστού νερού χρήσης έχει συνδεθεί και ο αισθητήρας T3 έχει συνδεθεί
με το σύστημα, ο αισθητήρας T3 ενεργοποιείται αυτόματα κατά την εκκίνηση.
Το ζεστό νερό έχει προτεραιότητα και ελέγχεται από τον αισθητήρα T3 στο
θερμοδοχείο. Όταν το θερμοδοχείο έχει θερμανθεί, η λειτουργία θέρμανσης
απενεργοποιείται προσωρινά μέσω μιας τρίοδης βαλβίδας. Όταν το θερμοδοχείο έχει
προθερμανθεί, η λειτουργία θέρμανσης συνεχίζεται από την αντλία θερμότητας.
Σχ. 9 Δοχείο ζεστού νερού χρήσης (mm)
1 Έξοδος ζεστού νερού χρήσης
2 Προστασία ανοδίου
3 Προσαγωγή νερού θέρμανσης
4 Σωλήνας αισθητήρα
5 Επιστροφή νερού θέρμανσης
6 Έισοδος κρύου νερού
7 Ποδαράκια στήριξης
8 Θερμόμετρο
9 Aνακυκλοφορία ΖΝΧ G3/4"
ΠΡΟΕΙΔΟΠΟΙΗΣΗ: Ελέγξτε αν το δάπεδο μπορεί να φέρει βάρος
108 + 200 kg (HR200) ή 140 + 300 kg (HR300).
Διατηρείτε το εγχειρίδιο για την αντλία θερμότητας πάντα σε προσιτό
σημείο, καθώς περιέχει τρέχουσες λύσεις συστήματος και
ηλεκτρολογικά σχέδια.
Όταν συνδέεται ένα δοχείο ζεστού νερού χρήσης στο σύστημα,
πρέπει να τοποθετηθεί μια αυτόματη βαλβίδα εξαέρωσης.
Ø 600
HR 200 = 1340, HR 300 = 1797
4
8
1
2
3
5
6
7
6720804927-01.1TL
9
11
HR 200 & HR 300 Lv
6 720 804 927 (2015/07)
Uzstādīšana
Pieskrūvējiet karstā ūdens tvertnes pamatnes skrūves ([7]).
Novietojiet karstā ūdens tvertni uz līdzenas virsmas.
Uzlieciet uz karstā ūdens tvertnes apvalku/pārsegu.
Piestipriniet termometru pie karstā ūdens tvertnes sānu sienas ([8]).
Uzstādiet uz siltumnesēja pievada automātisku atgaisotāju (E41.F111) - tam
jāatrodas tieši pie karstā ūdens tvertnes ([3]).
Uzlieciet siltumnesēja cauruli uz automātiskā atgaisotāja pie siltumnesēja pievada
([3]). Vārstu iemontē cauruļvadā (E21.Q21).
Piemontējiet pārslēgvārstu pie siltumsūkņa iekšējās daļas.
Piemontējiet turpgaitas sensoru (E11.T1) pie pārslēgvārsta otras ieejas.
Turpgaitas sensoram jābūt uzstādītam ne tuvāk kā vienu metru no pārslēgvārsta.
Skatiet sistēmas risinājumu rokasgrāmatā montierim.
Pievienojiet siltumnesēja cauruli pie siltumnesēja atgaitas ([5]) un siltumsūkņa
iekšējās daļas.
Pievienojiet padevi pie pārslēgvārsta (E21.Q21) un pieslēdziet vadības plati
iekšējās daļas sadales kārbā. Skatiet elektriskā slēguma shēmu rokasgrāmatā
montierim.
Novietojiet karstā ūdens sensoru (E41.T3) pie iespraužamās caurules, kas
atrodas karstā ūdens tvertnes ārpusē. Novietojiet sensoru apm. 600 mm
(HR200) vai apm. 800 mm (HR300) attālumā no karstā ūdens tvertnes
pamatnes.
Pieslēdziet karstā ūdens sensoru pie vadības plates iekšējās daļas sadales kārbā.
Skatiet elektriskā slēguma shēmu rokasgrāmatā montierim.
Pieslēdziet karstā ūdens ([1]) un aukstā ūdens ([6]) caurules.
Karstā ūdens temperatūras sensors T3
Ja karstā ūdens tvertne ir pieslēgta un T3 ir savienots ar sistēmu, ieslēdzot T3 tiek
atpazīts automātiski.
Karstajam ūdenim ir prioritāte un to vada karstā ūdens tvertnes sensors T3. Karstā
ūdens tvertnes uzsilšanas laikā apkures režīms uz brīdi tiek izslēgts ar pārslēgvārsta
starpniecību. Siltumsūkņa apkures režīms atkal ieslēdzas, tikko karstā ūdens tvertne
ir uzsilusi.
Att. 10 Karstā ūdens tvertne (mm)
1 Karstā ūdens izeja
2 Aizsarganods
3 Apkures ūdens turpgaita
4 Sensora caurule
5 Apkures ūdens atgaita
6 Aukstā ūdens ieeja
7 Balstskrūves
8 Termometrs
9 Karstā ūdens cirkulācija G3/4"
BRĪDINĀJUMS: Pārbaudiet, vai grīdas nestspēja ir pietiekama
108 + 200 kg (HR200) vai 140 + 300 kg (HR300) svaram.
Siltumsūkņa rokasgrāmatai vienmēr ir jāatrodas viegli pieejamā
vietā, jo tajā ir iekļauti aktuālie sistēmas risinājumi un elektrisko
slēgumu shēmas.
Ja pie sistēmas tiek pieslēgts karstā ūdens sildītājs (tvertne),
nepieciešams uzstādīt automātisku atgaisošanas vārstu.
Ø 600
HR 200 = 1340, HR 300 = 1797
4
8
1
2
3
5
6
7
6720804927-01.1TL
9
12
HR 200 & HR 300 Lt
6 720 804 927 (2015/07)
Montavimas
Po karšto vandens paruošimo įrenginiu prisukite reguliuojamas kojeles ([7]).
Karšto vandens paruošimo įrenginį pastatykite ant lygaus pagrindo.
Ant karšto vandens paruošimo įrenginio uždėkite apvalkalą ar gaubtą.
Prie karšto vandens paruošimo įrenginio šono pritvirtinkite termometrą ([8]).
Šilumnešio įvade, tiesiai ant karšto vandens paruošimo įrenginio ([3])
primontuokite automatinį oro išleidimo įtaisą (E41.F111).
Prie šilumnešio įvade esančio automatinio oro išleidimo įtaiso ([3]) prijunkite
šilumnešio vamzdį. Vožtuvas įmontuojamas vamzdyne (E21.Q21).
Šilumos siurblio vidinėje dalyje įmontuokite perjungiamąjį vožtuvą.
Kitame perjungiamojo vožtuvo įvade primontuokite tiekiamo srauto jutiklį
(E11.T1). Tiekiamo srauto jutiklį primontuoti reikia bent vieno metro atstumu nuo
perjungiamojo vožtuvo. Žr. montuotojams skirtoje instrukcijoje pateiktą sistemos
sprendimą.
Prie šilumnešio grįžtančio srauto linijos pridėkite šilumnešio vamzdį ([5]) ir
prijunkite prie šilumos siurblio vidinės dalies.
Prie perjungiamojo vožtuvo (E21.Q21) ir valdymo plokštės, esančios vidinės
dalies skirstomojoje dėžėje, prijunkite maitinimo liniją. Žr. montuotojams skirtoje
instrukcijoje pateiktą elektrinių sujungimų schemą.
Prie įstatomojo vamzdžio, esančio karšto vandens paruošimo įrenginio išorinėje
pusėje, pritvirtinkite karšto vandens jutiklį (E41.T3). Jutiklį tvirtinkite maždaug
600 mm (HR200) arba 800 mm (HR300) atstumu nuo karšto vandens
paruošimo įrenginio pagrindo.
Prie valdymo plokštės, esančios vidinės dalies skirstomojoje dėžėje, prijunkite
karšto vandens jutiklį. Žr. montuotojams skirtoje instrukcijoje pateiktą elektrinių
sujungimų schemą.
Prijunkite vamzdį karštam vandeniui ([1]) ir šaltam vandeniui ([6]).
Karšto vandens temperatūros jutiklis T3
Kai karšto vandens paruošimo įrenginys yra prijungtas, o T3 sujungtas su sistema, tai
T3 paleidimo metu įjungiamas automatiškai.
Karšto vandens ruošimas yra prioritetinis, jį valdo karšto vandens paruošimo
įrenginyje esantis jutiklis T3. Kai paruošimo įrenginys įšyla, šildymo režimas
perjungiamuoju vožtuvu laikinai išjungiamas. Kai paruošimo įrenginys atvėsta,
šilumos siurblys vėl pradeda veikti šildymo režimu.
Pav. 11 Karšto vandens paruošimo įrenginys (mm)
1 Karšto vandens išvadas
2 Apsauginis anodas
3 Šildymo sistemos vandens tiekiamas srautas
4 Jutiklio vamzdis
5 Šildymo sistemos vandens grįžtantis srautas
6 Šalto vandens įvadas
7 Reguliuojamos kojelės
8 Termometras
9 Karšto vandens cirkuliacija G3/4"
ĮSPĖJIMAS: prašome patikrinti, ar grindys atlaiko 108 + 200 kg
(HR200) arba 140 + 300 kg (HR300) svorį.
Šilumos siurblio instrukciją visada laikykite pasiekiamoje vietoje,
nes joje pateikti aktualūs sistemos sprendimai ir elektrinių
sujungimų schemos.
Jei prie sistemos prijungtas karšto vandens paruošimo įrenginys,
reikia primontuoti automatinį oro išleidimo vožtuvą.
Ø 600
HR 200 = 1340, HR 300 = 1797
4
8
1
2
3
5
6
7
6720804927-01.1TL
9
13
HR 200 & HR 300 Pt
6 720 804 927 (2015/07)
Instalação
Colocar os parafusos de nivelamento por baixo do aquecedor de água ([7]).
Colocar o aquecedor de água sobre uma superfície plana.
Colocar o invólucro/tampa no aquecedor de água.
Colocar lateralmente o termómetro do aquecedor de água ([8]).
Colocar um purgador automático (E41.F111) na admissão do líquido de calor
directamente no aquecedor de água ([3]).
Colocar um tubo para líquido de calor no purgador automático na admissão do
líquido de calor ([3]). Válvula é montada nos tubos (E21.Q21).
Colocar válvula selectora na peça interior da bomba de calor.
Colocar sonda de avanço (E11.T1) na outra entrada da válvula selectora. A sonda
de avanço deve ser colocada no mínimo um metro afastada da válvula selectora.
Ver solução de sistema no manual para instaladores.
Colocar o tubo para líquido de calor no tubo de retorno do líquido de calor ([5])
e ligar á peça interior da bomba de calor.
Ligar a alimentação da válvula selectora (E21.Q21) e a placa de circuito no qua-
dro eléctrico da peça interior. Ver esquema de circuitos eléctricos no manual para
instaladores.
Colocar o aquecedor de água (E41.T3) no tubo de encaixe no lado exterior do
aquecedor de água. Colocar a sonda numa distância de aprox. 600 mm (HR200)
ou aprox. 800 mm (HR300) do piso do aquecedor de água.
Ligar o sensor de água quente á placa de circuito impresso no quadro eléctrico da
peça interior. Ver esquema de circuitos eléctricos no manual para instaladores.
Tubo para água quente ([1]) e água fria ([6]).
Sensor de temperatura da água quente T3
Se o aquecedor de água quente estiver ligado e T3 conectado com o sistema o T3 é
confirmado automaticamente ao arranque.
Água quente é prioridade e comandado pelo sensor T3 no aquecedor de água.
Quando o aquecedor estiver quente o modo de aquecimento é desligado temporaria-
mente através da válvula selectora. Se o aquecedor estiver quente o modo de aque-
cimento da bomba de calor continua.
Fig. 12 Aquecedor de água (mm)
1 Saída de água quente
2 Ânodo de sacrifício
3 Avanço água quente
4 Tubo sonda
5 Tubo de retorno água quente
6 Entrada de água fria
7 Parafusos de nivelamento
8 Termómetro
9 Circulação de água quente G3/4"
AVISO: Verifique se o piso suporta um peso de 108 + 200 kg
(HR200) ou 140 + 300 kg (HR300) .
Mantenha o manual para a bomba de calor sempre acessível, visto
que contém soluções de sistemas actuais e esquemas eléctricos.
Quando um aquecedor de água é ligado ao sistema deve ser colo-
cada uma válvula de purga automática.
Ø 600
HR 200 = 1340, HR 300 = 1797
4
8
1
2
3
5
6
7
6720804927-01.1TL
9
14
HR 200 & HR 300 Sk
6 720 804 927 (2015/07)
Inštalácia
Pod zásobníkový ohrievač teplej vody namontujte pätkové skrutky ([7]).
Zásobníkový ohrievač teplej vody umiestnite na rovný podklad.
Na zásobníkový ohrievač teplej vody namontujte plášť/kryt.
Na bočnú stranu zásobníkového ohrievača teplej vody namontujte teplomer
([8]).
Na prívode teplonosného média namontujte automatický odvzdušňovací ventil
(E41.F111), priamo na zásobníkový ohrievač teplej vody ([3]).
Na automatický odvzdušňovací ventil na prívode teplonosného média namontujte
potrubie teplonosného média ([3]). Ventil sa montuje do potrubia (E21.Q21).
Do vnútornej časti tepelného čerpadla namontujte dvojcestný ventil.
Na druhý vstup dvojcestného ventilu namontujte snímač výstupu (E11.T1).
Snímač výstupu musí byť namontovaný vo vzdialenosti min. jeden meter od
dvojcestného ventilu. Viď systémové riešenie v príručke pre inštalatérov.
Namontujte potrubie s teplonosným médiom na spiatočku teplonosného média
([5]) a pripojte ho k vnútornej časti tepelného čerpadla.
Napájanie pripojte k dvojcestnému ventilu (E21.Q21) a doske s plošnými spojmi
v el. rozvádzači vo vnútornej časti. Viď schému el. zapojenia v príručke pre
inštalatérov.
Snímač teplej vody (E41.T3) umiestnite do zásuvného potrubia na vonkajšej
strane zásobníkového ohrievača teplej vody. Snímač namontujte s odstupom cca.
600 mm (HR200) alebo cca. 800 mm (HR300) od dna zásobníkového ohrievača
teplej vody.
Pripojte snímač teploty teplej vody k doske s plošnými spojmi v el. rozvádzači vo
vnútornej časti. Viď schému el. zapojenia v príručke pre inštalatérov.
Pripojte potrubie teplej vody ([1]) a studenej vody ([6]).
Snímač teploty teplej vody T3
Ak je zásobníkový ohrievač teplej vody pripojený a T3 je prepojený so systémom, tak
sa pri nábehu T3 automaticky potvrdí.
Teplá voda má prednosť a jej teplotu riadi snímač T3 v zásobníkovom ohrievači teplej
vody. Ak je zásobníkový ohrievač teplej vody zohriaty, tak sa vykurovacia prevádzka
dočasne vypne pomocou dvojcestného ventilu. Ak je zásobníkový ohrievač teplej
vody zohriaty, bude vykurovacia prevádzka pokračovať pomocou tepelného
čerpadla.
Obr. 13 Zásobníkový ohrievač teplej vody (mm)
1 Vývod teplej vody
2 Reakčná anóda
3 Výstup vykurovacej vody
4 Rúrka snímača
5 Spiatočka vykurovacej vody
6 Prívod studenej vody
7 Pätkové skrutky
8 Teplomer
9 Cirkulácia teplej vody G3/4"
VÝSTRAHA: Skontrolujte prosím, či má podlaha nosnosť
108 + 200 kg (HR200) príp. 140 + 300 kg (HR300).
Príručku pre tepelné čerpadlo majte vždy po ruke, pretože sú v nej
uvedené aktuálne systémové riešenia a schémy el. zapojenia.
Ak je k systému pripojený zásobníkový ohrievač teplej vody, je
nutné nainštalovať automatický odvzdušňovací ventil.
Ø 600
HR 200 = 1340, HR 300 = 1797
4
8
1
2
3
5
6
7
6720804927-01.1TL
9
15
HR 200 & HR 300 Sl
6 720 804 927 (2015/07)
Namestitev
Pod bojler namestite nastavljive nogice ([7]).
Bojler postavite na ravno podlago.
Na bojler namestite plašč/pokrov.
Namestite termometer na strani bojlerja ([8]).
Samodejni odzračevalnik (E41.F111) namestite neposredno na vstopu
ogrevalnega voda v bojler ([3]).
Cev ogrevalnega voda priključite na samodejni odzračevalnik na dotoku medija
([3]). Ventil se vgradi v cevovod (E21.Q21).
Preklopni ventil namestite v notranjo enoto toplotne črpalke.
Tipalo dvižnega voda (E11.T1) namestite na cevi na drugem vhodu v preklopni
ventil. Tipalo naj bo nameščeno vsaj en meter od preklopnega ventila. Glej
sistemske rešitve v navodilu za montažo.
Povratni vod izmenjevalca toplote priključite na notranjo enoto toplotne črpalke
([5]).
Napajanje preklopnega ventila (E21.Q21) priključite na električni stikalni omarici
v notranji enoti toplotne črpalke. Glej električni vezalni načrt v navodilu za
montažo.
Tipalo za toplo vodo (E41.T3) namestite v potopno tulko na zunanji strani
bojlerja. Tipalo namestite v razdalji približno 600 mm (HR200) ali približno
800 mm (HR300) od tal.
Tipalo za toplo vodo priključite na glavno ploščo v stikalni omarici notranje enote
toplotne črpalke. Glej električni vezalni načrt v navodilu za montažo.
Priključite cev za toplo vodo ([1]) in hladno vodo ([6]).
Temperaturno tipalo za toplo vodo T3
Ko je bojler za sanitarno vodo priključen in T3 povezan s sistemom, se T3 ob zagonu
samodejno potrdi.
Topla voda je na voljo in jo krmili tipalo T3 bojlerja. Ko je sanitarna voda v bojlerju
ogreta na nastavljeno temperaturo, se ogrevanje prek preklopnega ventila začasno
izklopi. Ko je voda v bojlerju segreta, toplotna črpalka nadaljuje z ogrevanjem
centralnega sistema, v kolikor je to potrebno.
Sl. 14 Bojler za sanitarno vodo (mm)
1 Izstop tople vode
2 Anoda
3 Ogrevalni vod
4 Potopna tulka
5 Povratni vod
6 Vstop hladne vode
7 Nastavljive noge
8 Termometer
9 Cirkulacija tople vode G3/4"
OPOZORILO: Preverite, ali tla vzdržijo težo 108 + 200 kg
(HR200) oz. 140 + 300 kg (HR300).
Priročnik za toplotno črpalko imejte vedno na dosegu roke, saj
vsebuje aktualne sistemske rešitve in električne vezalne načrte.
Če se na sistem priključi tudi bojler, je treba namestiti samodejni
odzračevalni ventil.
Ø 600
HR 200 = 1340, HR 300 = 1797
4
8
1
2
3
5
6
7
6720804927-01.1TL
9
16
HR 200 & HR 300 Cs
6 720 804 927 (2015/07)
Instalace
Stavěcí šrouby namontujte pod ohřívač teplé vody ([7]).
Ohřívač teplé vody postavte na rovný podklad.
Na ohřívač teplé vody instalujte obal/kryt.
Na bok ohřívače připevněte teploměr ([8]).
Na přítok teplonosné látky, přímo na ohřívač teplé vody, namontujte automatický
odvzdušňovač (E41.F111) ([3]).
Na přívodní potrubí nositele tepla instalujte automatický odvzdušňovač ([3]).
Ventil se montuje do potrubí (E21.Q21).
Přepínací ventil namontujte na vnitřní jednotku tepelného čerpadla.
Čidlo výstupní teploty (E11.T1) umístěte na druhém vstupu přepínacího ventilu.
Čidlo výstupní teploty musí být umístěno ve vzdálenosti alespoň jeden metr od
přepínacího ventilu. Viz systémové řešení v příručce pro instalatéry.
Potrubí teplonosné látky připojte na zpátečku teplonosné látky ([5]) a na
vnitřní jednotku tepelného čerpadla.
Napájení připojte na přepínací ventil (E21.Q21) a na řídicí desku v rozváděči
vnitřní jednotky. Viz elektrické schéma zapojení v příručce pro instalatéry.
Čidlo teplé vody (E41.T3) umístěte do jímky na vnější straně ohřívače teplé vody.
Čidlo umístěte ve vzdálenosti asi 600 mm (HR200) nebo asi 800 mm (HR300)
ode dna ohřívače teplé vody.
Čidlo teplé vody připojte na řídicí desku v rozváděči vnitřní jednotky. Viz
elektrické schéma zapojení v příručce pro instalatéry.
Připojte trubku pro teplou vodu ([1]) a pro studenou vodu ([6]).
Čidlo výstupní teploty teplé vody T3
Je-li ohřívač teplé vody připojen a čidlo T3 spojeno se systémem, dojde při ohřevu k
automatickému potvrzení čidla T3.
Teplá voda má přednost a je řízena čidlem T3 v ohřívači teplé vody. Je-li akumulační
zásobník ohřívající teplou vodu zahřátý, vypne se na přechodnou dobu přepínací
ventil pro vytápění. Ohřívá-li se akumulační zásobník, pokračuje také tepelné
čerpadlo v provozu vytápění.
Obr. 15 Ohřívač teplé vody (mm)
1 Výstup teplé vody
2 Obětní (degradační) anoda
3 Výstup otopná voda
4 Trubka čidla
5 Zpátečka otopná voda
6 Vstup studené vody
7 Stavěcí šrouby
8 Teploměr
9 Cirkulace teplé vody G3/4"
VÝSTRAHA: Zkontrolujte, zda podlaha unese hmotnost
108 + 200 kg (HR200) popř. 140 + 300 kg (HR300).
Příručku pro tepelné čerpadlo mějte vždy po ruce, protože jsou v
ní obsažena aktuální systémová řešení a elektrická schémata
zapojení.
Pokud se zařízení na přípravu teplé vody připojuje na systém, je
nutné namontovat automatický odvzdušňovací ventil.
Ø 600
HR 200 = 1340, HR 300 = 1797
4
8
1
2
3
5
6
7
6720804927-01.1TL
9
17
HR 200 & HR 300 NL
6 720 804 927 (2015/07)
Installatie
Monteer de stelpoten onder de boiler ([7]).
Plaats de boiler op een vlakke ondergrond.
Monteer de mantel/kap op de boiler.
Monteer de thermometer op de zijkant van de boiler ([8]).
Monteer de cv-aanvoerleiding tussen de binnenunit van de warmtepomp en de
boiler ([3]). Plaats een driewegklep en een automatische ontluchter in de cv-
aanvoerleiding. Plaats de ontluchter zo dicht mogelijk bij het aansluitpunt op de
boiler (E21.Q21).
Sluit de driewegklep aan op de printplaat in de binnenunit.
Monteer de aanvoertemperatuursensor (E11.T1) op de cv-aanvoerleiding tussen
de binnenunit en de driewegklep. Plaats de sensor op minimaal 1 meter afstand
van de driewegklep. Zie voor de hydraulische aansluitschema's de installatie in-
structie van de warmtepomp.
Monteer de cv-retourleiding tussen de cv -retouraansluiting van de boiler ([5])
en de cv- retouraansluiting van de binnenunit.
Sluit de voedingspanning van de driewegklep (E21.Q21) aan op de printkaart in
de binnenunit. Zie de elektrische aansluitschema's in de installatie-instructie van
de warmtepomp.
Plaats de boilersensor (E41.T3) in de dompelbuis op ca. 600mm (HR200) of ca.
800mm (HR300) van de bodem van de boiler.
Sluit de boilersensor aan op de printplaat in de binnenunit. Zie de elektrische aan-
luitschema's in de installatie-instructie van de warmtepomp.
Sluit de leidingen voor warmwater ([1]) en koud water ([6]) aan.
Boilersensor T3
Wanneer de boiler is aangesloten en boilersensor T3 is met de binnenunit verbon-
den, dan wordt boilersensor T3 bij het starten automatisch bevestigd.
De bereiding van warmwater heeft voorrang op het cv-bedrijf.. Wanneer de boiler
wordt opgewarmd, wordt het cv-bedrijf tijdelijk via de driewegklep uitgeschakeld.
Wanneer de boiler is opgewarmd, wordt het cv-bedrijf door de warmtepomp voort-
gezet.
Afb. 16 Boiler (mm)
1 Warmwateruitlaat
2 Opofferingsanode
3 Aanvoer cv-water
4 Dompelbuis
5 Retour cv-water
6 Ingang koud tapwater
7 Instelbare stelpoten
8 Thermometer
9 Warmwatercirculatie G3/4"
WAARSCHWUWING: controleer of de vloer een gewicht van
108 + 200 kg (HR200) resp. 140 + 300 kg (HR300) kan dragen.
Houd de installatie-instructie van de warmtepomp altijd binnen
handbereik, omdat deze actuele systeemoplossingen en elektri-
sche schakelschema's bevat.
Breng een automatisch ontluchtingsventiel aan, wanneer een boi-
ler op het systeem wordt aangesloten.
Ø 600
HR 200 = 1340, HR 300 = 1797
4
8
1
2
3
5
6
7
6720804927-01.1TL
9
18
HR 200 & HR 300 Es
6 720 804 927 (2015/07)
Instalación
Colocar los tornillos niveladores bajo el calentador de agua ([7]).
Colocar el calentador de agua sobre una base plana.
Instalar la cubierta/capota en el calentador de agua.
Instalar el termómetro en el lado del calentador de agua ([8]).
Instalar un purgador automático (E41F111) sobre la alimentación del caloporta-
dor, directamente en el calentador de agua ([3]).
Colocar la tubería del caloportador sobre el purgador automático en la alimenta-
ción del caloportador ([3]). Se monta la válvula en la tubería (E21.Q21).
Instalar la válvula de doble paso en la parte interior de la bomba de calefacción.
Instalar el sensor de avance (E11.T1) en la otra entrada de la válvula de doble
paso. El sensor de avance debe instalarse como mínimo a un metro de la válvula
de doble paso. Véase en las soluciones del sistema del manual para instaladores.
Colocar la tubería del caloportador en el retorno del caloportador ([5]) y
conectar esta a la parte interior de la bomba de calefacción.
Conectar la alimentación a la válvula de doble paso (E21.Q21) y la placa electró-
nica en el cuadro eléctrico de la parte interior. Véase el esquema de conexión eléc-
trica en el manual para instaladores.
Colocar el sensor de agua caliente (E41.T3) en la tubería de inserción en la parte
exterior del calentador de agua. Colocar el sensor a una distancia de aprox.
600 mm (HR200) o de aprox. 800 mm (HR300) de la base del calentador de
agua.
Conectar el sensor de agua caliente a la placa electrónica en el cuadro eléctrico de
la parte interior. Véase el esquema de conexión eléctrica en el manual para insta-
ladores.
Conectar el tubo para el agua caliente ([1]) y el agua fría ([6]).
Sensor de temperatura de agua caliente T3
Una vez esté conectado el calentador de agua y T3 con el sistema, al arrancar se con-
firma automáticamente T3.
El agua caliente tiene prioridad y es controlada por el sensor T3 en el calentador de
agua. Cuando el calentador esté calentado, a través de una válvula de doble paso se
desconecta temporalmente el funcionamiento de la calefacción. Una vez el calenta-
dor se haya recalentado, se prolonga el funcionamiento de la calefacción por la
bomba de calefacción.
Fig. 17 Calentador de agua (mm)
1 Salida de agua caliente
2 Ánodo protector
3 Avance del agua de calefacción
4 Tubería con sensor
5 Retorno del agua de calefacción
6 Entrada del agua fría
7 Tornillos niveladores
8 Termómetro
9 Circulación del agua caliente G3/4"
ADVERTENCIA: compruebe si el suelo soporta un peso de
108 + 200 kg (HR200) o 140 + 300 kg (HR300).
Tenga siempre al alcance el manual de la bomba de calefacción ya
que contiene soluciones del sistema y esquemas de conexión eléc-
trica actuales.
Cuando un calentador de agua se conecta al sistema, debe insta-
larse una válvula automática de purga de aire.
Ø 600
HR 200 = 1340, HR 300 = 1797
4
8
1
2
3
5
6
7
6720804927-01.1TL
9
19
HR 200 & HR 300 Ru
6 720 804 927 (2015/07)
Монтаж
Установите опорные ножки под водонагревателем ([7]).
Поставьте водонагреватель на ровную поверхность.
Установите крышку/кожух на водонагреватель.
Установите термометр на стороне водонагревателя ([8]).
Установите автоматический воздухоотводчик (E41.F111) на подаче
теплоносителя непосредственно на водонагревателе ([3]).
Установите трубу теплоносителя на автоматическом воздухоотводчике на
подаче теплоносителя ([3]). Воздухоотводчик монтируется в трубопровод
(E21.Q21).
Установите переключающий клапан на внутренней части теплового насоса.
Установите датчик подающей линии (E11.T1) на другом входе
переключающего клапана. Датчик подающей линии должен находиться на
расстоянии не менее одного метра от переключающего клапана. См.
системное решение в руководстве для монтажников.
Установите трубу теплоносителя на обратной линии ([5]) и подключите
внутреннюю часть теплообменника.
Подключите питание к переключающему клапану (E21.Q21) и электронной
плате в электрошкафу внутренней части. См. электросхему в руководстве
для монтажников.
Разместите датчик горячей воды (E41.T3) на вставной трубе на наружной
части водонагревателя. Разместите датчик на расстоянии около 600 мм
(HR200) или около 800 мм (HR300) от дна водонагревателя.
Подключите датчик горячей воды к электронной плате в электрошкафу
внутренней части. См. электросхему в руководстве для монтажников.
Подключите трубу горячей ([1]) и холодной ([6]) воды.
Датчик температуры горячей воды T3
Если подключен водонагреватель, и T3 соединён с системой, то T3
автоматически подтверждается при пуске.
Горячая вода имеет приоритет, и управление осуществляется от датчика T3 в
водонагревателе. Если водонагреватель нагрет, то режим нагрева временно
выключается переключающим клапаном. Если водонагреватель не нагрет до
заданной температуры, то режим нагрева продолжается от теплового насоса.
Рис. 18 Водонагреватель (мм)
1 Выход горячей воды
2 Анод протекторной защиты
3 Подающая линия греющей воды
4 Трубка датчика
5 Обратная линия греющей воды
6 Вход холодной воды
7 Опорные болты
8 Термометр
9 Циркуляция горячей воды G3/4"
ПРЕДУПРЕЖДЕНИЕ: Проверьте, выдержит ли пол вес
108 + 200 кг (HR200) и 140 + 300 кг (HR300).
Держите всегда под рукой руководство по тепловым насосам,
так как оно содержит актуальные системные решения и
электросхемы.
Если к системе подключен водонагреватель, то нужно
установить автоматический воздухоотводчик.
Ø 600
HR 200 = 1340, HR 300 = 1797
4
8
1
2
3
5
6
7
6720804927-01.1TL
9
20
HR 200 & HR 300 No
6 720 804 927 (2015/07)
Installasjon
Monter justeringsføttene på varmtvannsberederen ([7]).
Plasser varmtvannsberederen på et flatt underlag.
Monter en kappe på varmtvannsberederen.
Monter termometeret på siden av varmtvannsberederen ([8]).
Monter en automatisk avlufter (E41.F111) på
varmtvannsberederens inntak rett ved berederen ([3]).
Monter varmebærerrør til varmtvannsberederens inntak på den automatiske
avlufteren ([3]). Deretter monteres vekselventil (E21.Q21) på røret.
Koble vekselsventilen til varmepumpens innedel.
Monter fremledningsgiver (E11.T1) på vekselventilens andre inngang. Fremled-
ningsgiveren skal monteres minst en meter fra vekselventilen. Se systemløsnin-
gen i installatørhåndboken til varmepumpen.
Monter varmebærererør til varmtvannsberederens uttak ([5]) og koble til var-
mepumpens innedel.
Koble strømtilførselen til vekselventilen (E21.Q21) til kretskortet i innedelens
koblingsboks. Se elektrisk koblingsskjema i installatørhåndboken til varmepum-
pen.
Plasser varmtvannsføleren (E41.T3) i innstikksrøret på utsiden av varmtvannsbe-
rederen([4]). Føleren plasseres ca. 600 mm (HR200) eller ca. 800 mm
(HR300) fra bunnen av tanken.
Koble varmtvannsføleren til kretskortet i innedelens koblingsboks. Se elektrisk
koblingsskjema i installatørhåndboken til varmepumpen.
Anslutt rørene for varmtvann ([1]) og kaldvann ([6]).
Varmtvannsføler T3
Hvis varmtvannsbereder er tilkoblet og T3 er koblet til systemet, autokvitteres T3
ved oppstart.
Varmtvannet prioriteres og styres av føleren T3 i varmtvannsberederen. Når berede-
ren varmes, kobles varmedriften fra varmepumpen midlertidig bort via vekselventi-
len. Når vannet i berederen har nådd sin innstilte temeperatur, fortsetter
varmedriften fra varmepumpen.
Fig. 19 Varmtvannsbereder (mm)
1 Varmtvann ut
2 Offeranode
3 Varmebærer inn
4 Plassering av følere
5 Varmebærer ut
6 Kaldtvann inn
7 Justeringsføtter
8 Termometer
9 Varmtvannssirkulasjon G3/4"
H x D: HR 200 = 1340 x 600 mm, HR 300 = 1797 x 600 mm
ADVARSEL: Kontroller at gulvet
er dimensjonert for vekten108 + 200 kg (HR 200)
eller 140 + 300 kg (HR 300).
Ha installatørhåndboken til varmepumpen tilgjengelig, ettersom
den inneholder aktuelle systemløsninger og koblingsskjema.
En automatisk avluftningsventil må monteres da en varmtvanns-
bereder kobles til systemet.
Ø 600
HR 200 = 1340, HR 300 = 1797
4
8
1
2
3
5
6
7
6720804927-01.1TL
9
21
HR 200 & HR 300 Pl
6 720 804 927 (2015/07)
Instalacja
Śruby poziomujące wkręcić pod podgrzewacz c.w.u. ([7]).
Podgrzewacz c.w.u. ustawić na równym podłożu.
Osłonę/pokrywę umieścić na podgrzewaczu c.w.u.
Termometr umieścić z boku podgrzewacza c.w.u. ([8]).
Odpowietrznik automatyczny (E41.F111) zamontować na wejściu czynnika
grzewczego do podgrzewacza c.w.u. ([3]).
Rurę nośnika ciepła zamontować na odpowietrzniku automatycznym, na
dopływie nośnika ciepła ([3]). Zawór jest montowany w przewodzie rurowym
(E21.Q21).
Przełącznik obiegu (zawór 3-drogowy) umieścić na wewnętrznej części pompy
ciepła.
Czujnik temperatury zasilania (E11.T1) zamontować na innym wejściu
przełącznika obiegu. Czujnik temperatury zasilania musi zostać zamontowany
w minimalnym odstępnie od przełącznika obiegu wynoszącym jeden metr. Patrz
Rozwiązanie systemowe w instrukcji pompy ciepła dla instalatorów.
Rurę nośnika ciepła zamontować na powrocie nośnika ciepła ([5]) i podłączyć
do wewnętrznej części pompy ciepła.
Zasilanie podłączyć do przełącznika obiegu (E21.Q21) oraz płyty głównej
w skrzynce prądowej części wewnętrznej. Patrz Elektryczny schemat podłączenia
w podręczniku dla instalatorów.
Czujnik temperatury ciepłej wody (E41.T3) umieścić na rurze wtykowej po
zewnętrznej stronie podgrzewacza c.w.u. Czujnik umieścić w odległości około
600 mm (HR200) lub około 800 mm (HR300) od podłoża, na którym
umieszczony został podgrzewacz c.w.u.
Czujnik temperatury ciepłej wody podłączyć do płyty głównej w skrzynce
prądowej części wewnętrznej. Patrz Elektryczny schemat podłączenia
w podręczniku dla instalatorów.
Podłączyć rurę wody ciepłej ([1]) i rurę wody zimnej ([6]).
Czujnik temperatury c.w.u. T3
Jeśli podgrzewacz c.w.u. jest podłączony i T3 jest połączony z systemem, T3 jest
potwierdzany automatycznie podczas uruchomienia.
Przygotowanie c.w.u. jest priorytetowe i sterowane przez czujnik T3
w podgrzewaczu c.w.u. Podczas nagrzewania pogrzewacza tryb grzania jest
wyłączany przez przełącznik obiegu. Po nagrzaniu podgrzewacza pojemnościowego
pompa ciepła kontynuuje tryb grzania (c.o.)
Dane techniczne HR200/HR300
Pojemność użytkowa 200/300 [l]
Powierzchnia wymiany ciepła 1,8/2,6 [m2]
Znamionowa liczba mocy NL 1,8/2,3
Straty postojowe 1,8/2,2 [kWh/d]
Dopuszczalne ciśnienie robocze (c.o.) 10 [bar]
Dopuszczalne ciśnienie robocze (c.w.u.) 10 [bar]
Masa netto 105/138 [kg]
Rys. 20 Podgrzewacz c.w.u. (mm)
1 Wypływ ciepłej wody G1"
2 Anoda reakcyjna G5/4"
3 Zasilanie wody grzewczej G1"
4 Rurka czujnika
5 Powrót wody grzewczej G1"
6 Dopływ wody zimnej G1"
7 Nóżki śrubowe poziomujące
8 Termometr
9 Cyrkulacja c.w.u. G3/4"
OSTRZEŻENIE: należy się upewnić, że podłoże wytrzyma
obciążenie 108 + 200 kg (HR200) lub 140 + 300 kg (HR300).
Instrukcję instalacji do pompy ciepła należy przechowywać
zawsze w miejscu łatwo dostępnym, gdyż są w nim podane
rozwiązania systemowe oraz schematy elektryczne połączeń.
Przy podłączaniu podgrzewacza pojemnościowego c.w.u. do
systemu należy zamontować automatyczny zawór
odpowietrzający.
Ø 600
HR 200 = 1340, HR 300 = 1797
4
8
1
2
3
5
6
7
6720804927-01.1TL
9
22
HR 200 & HR 300
6 720 804 927 (2015/07)
[de] Wichtige Hinweise zur Installation/Montage
Die Installation/Montage muss durch eine für die Arbeiten zugelassene Fachkraft
unter Beachtung der geltenden Vorschriften erfolgen.
Mitgeltende Anleitungen von Anlagenkomponenten, Zubehören und Ersatzteilen
beachten.
Vor allen Arbeiten: Anlage allpolig spannungsfrei machen.
[en] Important notes on installation/assembly
The installation/assembly must be carried out by a professional who is authorised to
do the work, and with due regard to the relevant regulations.
Observe all the relevant instructions for other system components, accessories
and spare parts.
Before starting any work: disconnect the system from the power supply across all
phases.
[fr] Instructions importantes pour l’installation/le montage
L’installation/le montage doit être effectué(e) par un spécialiste qualifié pour les
opérations concernées et dans le respect des prescriptions applicables.
Respecter également les notices des composants de l’installation, des acces-
soires et des pièces de rechange.
Avant tous les travaux : couper la tension sur tous les pôles de l’installation.
[cs] Důležité pokyny k instalaci/montáži
Instalaci/montáž musí při dodržení platných předpisů provést odborný pracovník s
příslušným oprávněním pro tyto práce.
Řiďte se souvisejícími návody pro komponenty zařízení, příslušenství a náhradní
díly.
Před započetím všech prací: vypněte kompletně napájení do zařízení.
[el] Σημαντικές υποδείξεις για την εγκατάσταση/συναρμολόγηση
Η εγκατάσταση/συναρμολόγηση πρέπει να πραγματοποιείται από εξουσιοδοτημένο για
τις εργασίες αυτές τεχνικό προσωπικό, το οποίο θα πρέπει να φροντίζει ώστε να
τηρούνται οι ισχύουσες διατάξεις.
Λάβετε υπόψη τις συνοδευτικές οδηγίες που αφορούν τα εξαρτήματα της
εγκατάστασης, τους πρόσθετους εξοπλισμούς και τα ανταλλακτικά.
Πριν από οποιαδήποτε εργασία: Αποσυνδέστε όλους τους πόλους της εγκατάστασης
από το ρεύμα.
[es] Indicaciones importantes para instalación/montaje
La instalación/el montaje lo debe realizar personal especializado autorizado para los
trabajos, respetando las prescripciones vigentes.
Respetar las instrucciones de referencia de los componentes de la instalación, los
accesorios y las piezas de repuesto.
Antes de todos los trabajos: eliminar la tensión en todos los polos de la instala-
ción.
[et] Olulised juhised paigaldamiseks/montaažiks
Paigaldamist/montaaži tohib läbi viia selleks volitusi omav spetsialist, arvestades
kehtivaid nõudeid.
Tuleb järgida kõiki seadme komponentide, tarvikute ja varuosade kohta
kaaskehtivaid juhendeid.
Enne kõigi tööde alustamist: muuta seadme kõik faasid pingevabaks.
[it] Avvertenze importanti per l'installazione/il montaggio
L'installazione/il montaggio deve aver luogo ad opera di una ditta specializzata ed
autorizzata in osservanza delle disposizioni vigenti.
Osservare le istruzioni allegate dei componenti dell'impianto, degli accessori e
delle parti di ricambio.
Prima di tutti i lavori: staccare completamente l'alimentazione elettrica
dell'impianto.
[lt] Svarbios instaliavimo ir (arba) montavimo nuorodos
Instaliuoti ir montuoti, laikantis galiojančių taisyklių, leidžiama kvalifikuotiems
specialistams, kurie buvo įgalioti šiems darbams atlikti.
Taip pat laikykitės įrenginio komponentų, priedų ir atsarginių dalių galiojančių
instrukcijų.
Prieš pradėdami bet kokius darbus: atjunkite įrenginio visų fazių srovę.
[lv] Svarīgi norādījumi par iekārtas uzstādīšanu / montāžu
Iekārtas uzstādīšanu/montāžu ir jāveic specializētam sertificētam speciālistam,
ievērojot spēkā esošos noteikumus.
Ievērojiet iekārtas komponentu, piederumu un rezerves daļu instrukcijas.
Pirms jebkādu darbu uzsākšanas: izslēdziet iekārtas strāvas padevi visiem
poliem.
[nl] Belangrijke aanwijzingen betreffende de installatie/montage
De installatie/montage moet worden uitgevoerd door een voor de werkzaamheden
geautoriseerde installateur rekening houdend met de geldende voorschriften.
Respecteer tevens geldende handleidingen van installatiecomponenten, toebe-
horen en reserveonderdelen.
Voor alle werkzaamheden: installatie over alle polen spanningsloos schakelen.
[pt] Indicações importantes relativas à instalação/montagem
A instalação/montagem deve ser efectuada por um técnico especializado com quali-
ficações para estes trabalhos, tendo em atenção os regulamentos em vigor.
Ter em consideração as instruções aplicáveis de componentes da instalação,
acessórios e peças de substituição.
Antes de todos os trabalhos: desligar a instalação da corrente em todos os pólos.
[ru] Важные указания по подключению/монтажу
Подключение/монтаж должны выполнять специалисты, имеющие допуск к
выполнению таких работ, при соблюдении действующих норм и правил.
Выполняйте требования сопутствующих инструкций на компоненты
установки, дополнительное оборудование и запчасти.
Перед выполнением любых работ: обесточьте установку отключением всех
фаз.
[sk] Dôležité pokyny týkajúce sa inštalácie/montáže
Inštaláciu/montáž musí realizovať odborník s oprávnením na výkon týchto prác,
pričom musí dodržovať platné predpisy.
Dodržujte inštrukcie uvedené v súvisiacich návodoch ku komponentom
zariadenia, príslušenstvu a náhradným dielom.
Pred začiatkom všetkých prác: Odpojte všetky póly el. napájania zariadenia.
[sl] Pomembni napotki za namestitev/montažo
Namestitev/montažo mora izvesti strokovnjak, pristojen za tovrstna dela, ob
upoštevanju veljavnih predpisov.
Upoštevajte priložena veljavna navodila komponent naprave, priborov in
nadomestnih delov.
Pred vsemi deli: izklopite napravo iz vseh polov.
[sv] Viktiga anvisningar för installation/montering
Installationen/monteringen måste utföras av en behörig och fackkunnig person
enligt gällande föreskrifter.
Tillämpliga instruktioner för systemkomponenter, tillbehör och reservdelar ska
också följas.
Före alla arbeten ska anläggningen försättas i spänningsfritt tillstånd.
[tr] Kurulum/Montaj ile ilgili önemli uyarılar
Kurulum/Montaj çalışmaları sadece yetkili bayiler tarafından aşağıda belirtilen
talimatlar dikkate alınarak yapılmalıdır.
Tesisat parçalarına, aksesuarlara ve yedek parçalara ait talimatları dikkate alın.
Çalışmaya başlamadan önce: Enerji beslemesinin tüm kutuplarını ayırarak
tesisatın enerji beslemesini kesin.
[pl] Ważne wskazówki dotyczące instalacji/montażu
Instalację/montaż powinien wykonać specjalista uprawniony do tego typu prac
zuwzględnieniem aktualnie obowiązujących przepisów.
Przestrzegać dodatkowych instrukcji dołączonych do części instalacji, osprzętu
dodatkowego oraz części zamiennych.
Przed przystąpieniem do wykonywania wszelkich prac: odłączyć instalację od
zasilania sieciowego (wszystkie bieguny).
23
HR 200 & HR 300
6 720 804 927 (2015/07)
Bosch Thermotechnik GmbH
Sophienstraße 30-32
D-35576 Wetzlar/Germany

Documenttranscriptie

HR 200 & HR 300 Installation instructions • • • • • Swedish (Sv) ................................................. English (En) ................................................... French (Fr) ................................................... Italian (It) ...................................................... Turkish (Tr) ................................................... • • • • • • • • • • German (De) ................................................. 7 Estonian (Et).................................................. 8 NL (Be) ........................................................ 9 Greek (El).................................................... 10 Latvian (Lv) ................................................. 11 Lithuanian (Lt) ............................................. 12 Portuguese (pt) ........................................... 13 Slovak (Sk) ................................................. 14 Slovene (Sl) ................................................ 15 Czech (Cs)................................................... 16 • • • • • Netherlands (NL) ......................................... 17 Spanish (Es) ............................................... 18 Russian (Ru) ............................................... 19 Norwegian (No) ........................................... 20 Polish (Pl) ................................................... 21 – 2 3 4 5 6 Montážní návod 6 720 804 927 (2015/07) 1 HR 200 & HR 300 Sv Installation 1 2 VARNING: Kontrollera att golvet håller för vikten 108 + 200 kg (HR 200) eller 140 + 300 kg (HR 300). Ha installatörshandboken för värmepumpen tillgänglig, då denna innehåller aktuella systemlösningar och elscheman. 8 ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ HR 200 = 1340, HR 300 = 1797 En automatisk avluftningsventil måste monteras då en varmvattenberedare ansluts till systemet. 3 Montera justeringsfötterna på varmvattenberedaren ([7]). Placera varmvattenberedaren på ett plant underlag. Montera svep/kappa på varmvattenberedaren. Montera termometern på sidan av varmvattenberedaren ([8]). Montera en automatisk avluftare (E41.F111) på varmvattenberedarens inflöde alldeles vid beredaren ([3]). Montera värmebärarrör till varmvattenberedarens inflöde på den automatiska avluftaren ([3]). Montera därefter växelventilen (E21.Q21) på röret. Anslut växelventilen till värmepumpens innedel. Montera framledningsgivare (E11.T1) på växelventilens andra ingång. Framledningsgivaren ska monteras minst en meter från växelventilen. Se systemlösning i installatörshandboken för värmepumpen. Montera värmebärarrör till varmvattenberedarens utflöde ([5]) och anslut till värmepumpens innedel. Anslut strömmatningen till växelventilen (E21.Q21) till kretskort i innedelens ellåda. Se elschema i installatörshandboken för värmepumpen. Placera varmvattengivaren (E41.T3) i insticksröret på utsidan av varmvattenberedaren([4]). Givaren placeras cirka 600 mm (HR200) eller cirka 800 mm (HR300) från botten av tanken. Anslut varmvattengivaren till kretskort i innedelens ellåda. Se elschema i installatörshandboken för värmepumpen. Anslut rör för varmvatten ([1]) och kallvatten ([6]). 9 4 5 6 7 Varmvattengivare T3 Ø 600 Om varmvattenberedare är ansluten och T3 är kopplad till systemet, autokvitteras T3 vid uppstart. 6720804927-01.1TL Varmvattnet prioriteras och styrs av givaren T3 i varmvattenberedaren. När beredaren värms kopplas värmedriften från värmepumpen tillfälligt bort via växelventilen. När beredaren är uppvärmd fortsätter värmedriften från värmepumpen. Bild 1 1 2 3 4 5 6 7 8 9 Varmvattenberedare (mm) Varmvatten ut Offeranod Värmebärare in Placering av givare Värmebärare ut Kallvatten in Justeringsfötter Termometer Varmvattencirkulation G3/4" H x D: HR 200 = 1340 x 600 mm, HR 300 = 1797 x 600 mm 6 720 804 927 (2015/07) 2 HR 200 & HR 300 En Installation 1 2 WARNING: Make sure that the floor can hold 108 + 200 kg (HR 200) or 140 + 300 kg (HR 300). Keep the installer manual for the Heat Pump available as a reference for the relevant system solutions and wiring diagrams. 8 ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ HR 200 = 1340, HR 300 = 1797 An automatic venting valve must be installed when a hot water cylinder is connected to the system. 3 Install the adjustment feet on the hot water cylinder ([7]). Position the hot water cylinder on a level base. Install the sweep/cover on the hot water cylinder. Install the thermometer on the side of the hot water cylinder ([8]). Install an automatic venting valve (E41.F111) on the inflow of the heat transfer fluid ([3]). Install a pipe for heat transfer fluid on the automatic venting valve ([3]) and install the three-way valve (E21.Q21) on the pipe. Connect the three-way valve to the indoor part of the heat pump. Install the flow sensor (E11.T1) on the other inlet to the three-way valve. The flow sensor must be positioned at least one metre from the three-way valve. Refer to the system diagram in the installer manual for the Heat Pump. Install pipes for the heat transfer fluid between the outlet for the transfer fluid ([5]) and the indoor part of the heat pump. Connect the power supply for the three-way valve (E21.Q21) to the circuit board in the electric box of the indoor unit. Refer to the electric diagram in the installer manual for the Heat Pump. Install the hot water sensor (E41.T3) in the dipstick pipe on the outside of the hot water cylinder ([4]). Position the sensor approximately 600 mm (HR200) or approximately 800 mm (HR300) from the bottom of the cylinder. Connect the hot water sensor to the circuit board in the electric box of the indoor unit. Refer to the electric diagram in the installer manual for the Heat Pump. Connect domestic hot water ([1]) and domestic cold water ([6]). 6 7 Ø 600 If a hot water cylinder is installed and T3 is connected to the system, T3 is automatically acknowledged at start-up. 6 720 804 927 (2015/07) 4 5 Hot water sensor T3 Hot water is prioritised and controlled by the sensor T3 in the hot water cylinder. While water is being heated in the cylinder, the heating system from the heat pump is temporarily disconnected thorugh the three-way valve. The heating operation from the heat pump continues when the water in the cylinder has reached the set temperature. 9 6720804927-01.1TL Fig. 2 1 2 3 4 5 6 7 8 9 How water cylinder (mm) Hot water, out Sacrificial anode Heat transfer fluid, in Positioning sensor Heat transfer fluid, out Cold water, in Adjustable feet Thermometer DHW circulation G3/4" 3 HR 200 & HR 300 Fr Installation 1 2 AVERTISSEMENT : Vérifiez que le sol supporte une charge de 108 + 200 kg (HR 200) ou 140 + 300 kg (HR 300). Aidez-vous du guide d'installation comme référence qui contient les solutions système et les schémas électriques actuels. 8 ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ HR 200 = 1340, HR 300 = 1797 Un purgeur automatique doit être raccordé du fait que le ballon ECS est relié au système. 3 Installer les pieds de réglage sur le ballon ECS ([7]). Placer le ballon ECS sur une surface plane. Installer l'enveloppe/le capot sur le ballon ECS Installer le thermomètre sur le côté du ballon ECS ([8]). Installer un purgeur automatique (E41.F111) sur l'entrée du fluide caloporteur près du chauffe-eau ([3]). Installer un tuyau de fluide caloporteur sur le purgeur automatique placé à l'entrée du fluide caloporteur. Installer le robinet inverseur (E21.Q21) sur le tuyau. Raccorder le robinet inverseur à l'unité intérieure de la pompe à chaleur. Installer la sonde de départ (E11.T1) sur l'autre entrée du robinet inverseur. La sonde de départ doit être installée à au moins un mètre du robinet. Voir les solutions systèmes dans le manuel d'installation. Installer le tuyau de fluide caloporteur à la sortie de fluide caloporteur ([5]) et raccorder ce tuyau à l'unité intérieure de la pompe à chaleur. Brancher l'alimentation électrique du robinet inverseur (E21.Q21) à la carte électronique qui se trouve dans le boîtier électrique de l'unité intérieure de la pompe. Voir le schéma électrique dans le manuel d'installation. Installer la sonde ECS (E41.T3) dans le tube d‘entrée qui se place sur l‘extérieure du ballon ECS ([4]). Placer la sonde à environ 600 mm (HR200) ou environ 800 mm (HR300) du fond du ballon ECS. Raccordez la sonde ECS dans le boîtier électrique de l‘unité intérieure, sur la carte à circuits imprimés. Voir le schéma électrique dans le manuel d'installation. Raccordez l'eau chaude sanitaire ([1]) et l'eau froide ([6]). 6 7 Ø 600 Si un ballon ECS est raccordé et que T3 est connecté au système, T3 s'auto-valide lors de la mise en route. 6 720 804 927 (2015/07) 4 5 Sonde ECS T3 L'eau chaude sanitaire est prioritaire. Elle est commandée par la sonde T3 dans le ballon ECS. Lorsque le ballon ECS chauffe, le mode chauffage est momentanément suspendu au moyen d'une vanne d‘inversion. Une fois que l'eau du ballon ECS a atteint la température souhaitée, la pompe à chaleur reprend le mode chauffage. 9 6720804927-01.1TL Fig. 3 1 2 3 4 5 6 7 8 9 Ballon ECS (mm) Eau chaude sanitaire, sortie Anode sacrificielle Fluide caloporteur, entrée Emplacement de la sonde Fluide caloporteur, sortie Eau froide, entrée Pieds de réglage Thermomètre Bouclage ECS fil. 3/4" 4 HR 200 & HR 300 It Installazione 1 2 AVVERTENZA: Accertarsi che il pavimento abbia una portata di 108 + 200 kg (HR 200) o 140 + 300 kg (HR 300). Tenere a portata di mano le istruzione di installazione della pompa di calore, che contiene le soluzioni di sistema e gli schemi elettrici pertinenti. 8 ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ HR 200 = 1340, HR 300 = 1797 Collegando un accumulatore produttore di acqua calda (detto in seguito anche più brevemente bollitore) all'impianto è necessario installare una valvola di sfiato automatica. 3 Montare i piedini di regolazione del bollitore ([7]). Posare il bollitore su una superficie piana. Montare il guscio/mantello del bollitore. Montare il termometro sul lato del bollitore ([8]). Montare uno sfiato automatico (E41.F111) sull'ingresso del fluido termovettore del bollitore, nelle immediate vicinanze del bollitore ([3]). Montare il tubo del fluido termovettore sullo sfiato automatico ([3]). Montare quindi la valvola a 3 vie (E21.Q21) sul tubo. Collegare la valvola a 3 vie all'unità interna della pompa di calore. Montare la sonda di temperatura di mandata (E11.T1) sull'altro ingresso della valvola a 3 vie. La sonda di temperatura di mandata deve essere montata ad almeno un metro di distanza dalla valvola a 3 vie. Vedere la soluzione di sistema le istruzione di installazione della pompa di calore. Montare il tubo di ritorno del fluido termovettore in uscita dal bollitore ([5]) e collegarlo all'unità interna della pompa di calore. Effettuare il collegamento elettrico della valvola a 3 vie (E21.Q21) alla scheda elettronica nell'armadietto elettrico dell'unità interna. Vedere lo schema elettrico ne le istruzione di installazione della pompa di calore. Posare la sonda di temperatura dell'acqua calda (E41.T3) nel tubo di innesto all'esterno del bollitore ([4]). la sonda di temperatura deve essere posizionato a circa 600 mm (HR200) o 800 mm (HR300) dal fondo del bollitore. Collegare la sonda di temperatura dell'acqua calda alla scheda elettronica nell'armadietto elettrico dell'unità interna. Vedere lo schema elettrico ne le istruzione di installazione della pompa di calore. Collegare i tubi dell'acqua calda ([1]) e fredda ([6]). Ha sempre priorità la produzione di acqua calda, comandata dalla sonda di temperatura T3 interna al bollitore. Durante l'approntamento sanitario, viene temporaneamente sospeso il riscaldamento tramite una valvola a 3 vie. Quando il bollitore ha riscaldato l'acqua, viene ripristinato il riscaldamento da parte della pompa di calore. 6 720 804 927 (2015/07) 4 5 6 7 Ø 600 Sonda di temperatura dell'acqua calda T3 Se nell'impianto è presente il bollitore e la sonda di temperatura T3 è collegata all'impianto, la sonda di temperatura è abilitata automaticamente all'avviamento. 9 6720804927-01.1TL Fig. 4 1 2 3 4 5 6 7 8 9 Caldaia (mm) Uscita dell'acqua calda Anodo sacrificale Ingresso del fluido termovettore Tubo di innesto (alloggiamento) per la sonda di temperatura Uscita del fluido termovettore Ingresso dell'acqua fredda Piedini di regolazione Termometro Ricircolo acqua calda sanitaria G3/4" 5 HR 200 & HR 300 Tr Kurulum 1 2 DİKKAT: Zeminin 108 + 200 kg (HR 200) yada 140 + 300 kg (HR 300) ağırlığını kaldırabileceğini kontrol edin. Gerekli sistem çözümleri ve devre şemalarını içerdiği için, kurulum kılavuzunu yanınızda hazır bulundurunuz. 8 ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ HR 200 = 1340, HR 300 = 1797 Sisteme bir boyler ekleneceği için otomatik hava pürjörü monte edilmelidir. 3 Boylere ([7]) ayarlanabilir ayakları monte ediniz. Boyleri düz zemine yerleştiriniz. Boylerin üzerine koruma/izolasyon monte ediniz. Termometreyi boylerin ([8]) yan tarafına monte ediniz. Otomatik hava pürjörünü (E41.F111) boylerin ([3]) iç akımınına, hemen ısıtıcının yanına monte ediniz. Boylerin iç akım kısmında bulunan otomatik hava pürjörü ([3]) üstüne ısı taşıyıcı boru monte ediniz. Daha sonra üç yollu vanayı (E21.Q21) boruya monte ediniz. Üç yollu vanayı ısı pompasının iç kısmına bağlayınız. Akış sensörünü (E11.T1) üç yollu vananın diğer girişine monte ediniz. Akış sensörü, üç yollu vananın en az bir metre uzağına monte edilmelidir. Isı pompası kurulum kılavuzunda bulunan sistem çözümlerine bakınız. Boylerin çıkış yoluna ([5]) ısı taşıyıcı boru monte edip, ısı pompasının iç kısmına bağlayınız. Üç yollu vananın (E21.Q21) güç kaynağını, iç kısımdaki elektrik kutusunun devre kartına bağlayınız. Isı pompasının kurulum kılavuzunda elektrik şemasına bakınız. Sıcak su sensörünü (E41.T3) boylerin dışındaki sensör yuvasına yerleştiriniz.([4]). Sensör tankın alt kısmından yaklaşık 600 mm (HR200) yada yaklaşık 800 mm (HR300) kadar üstüne yerleştirilir. Sıcak su sensörünü iç kısımda bulunan elektrik kutusunun devre kartına bağlayınız. Isı pompası kurulum kılavuzundaki elektrik şemasına bakınız. Sıcak su ([1]) ve soğuk su ([6]) için boru bağlantılarını yapınız. 9 4 5 6 7 Ø 600 Sıcak su sensörü T3 Eğer boyler devreye alınmış ve T3 sisteme bağlı ise, çalıştırılma ile birlikte T3 otomatik olarak algılanır. öncelik sıcak suya verilir ve boylerdeki T3 sensörü tarafından kontrol edilir. Boyler ısınırken ısıtıcı üç yollu vana vasıtasıyla geçici olarak devre dışı bırakılır. Boyler ısındıktan sonra ısıtma ısı pompasından devam eder. 6 720 804 927 (2015/07) 6720804927-01.1TL Res. 5 1 2 3 4 5 6 7 8 9 Boyler (mm) Sıcak su çıkış Anod çübüğü Isı taşıyıcı giriş Sensör yuvası Isı taşıyıcı çıkış Soğuk su giriş Ayarlanabilir ayaklar Termometre Sıcak kullanım suyu sirkülasyonu G3/4" 6 HR 200 & HR 300 De Installation 1 2 WARNUNG: Überprüfen Sie bitte, ob der Fußboden ein Gewicht von 108 + 200 kg (HR200) bzw. 140 + 300 kg (HR300) aushält. Halten Sie das Handbuch für für die Wärmepumpe immer griffbereit, da es aktuelle Systemlösungen und elektrische Schaltpläne enthält. 8 ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ HR 200 = 1340, HR 300 = 1797 Wenn ein Warmwasserbereiter an das System angeschlossen wird, muss ein automatisches Entlüftungsventil angebracht werden. 3 Die Fußschrauben unter dem Warmwasserbereiter anbringen ([7]). Den Warmwasserbereiter auf eine ebene Unterlage stellen. Hülle/Haube an dem Warmwasserbereiter anbringen. Das Thermometer an der Seite des Warmwasserbereiters anbringen ([8]). Einen automatischen Entlüfter (E41.F111) auf dem Zulauf des Wärmeträgers, direkt am Warmwasserbereiter anbringen ([3]). Wärmeträgerrohr auf dem automatischen Entlüfter am Zulauf des Wärmeträgers anbringen ([3]). Ventil wird in Rohrleitung eingebaut (E21.Q21). Das Wechselventil am Innenteil der Wärmepumpe anbringen. Vorlauffühler (E11.T1) am anderen Eingang des Wechselventils anbringen. Der Vorlauffühler muss mindestens einen Meter vom Wechselventil entfernt angebracht werden. Siehe Systemlösung im Handbuch für Installateure. Das Wärmeträgerrohr am Rücklauf des Wärmeträgers anbringen ([5]) und am Innenteil der Wärmepumpe anschließen. Einspeisung an das Wechselventil (E21.Q21) und die Leiterplatte im Stromkasten des Innenteils anschließen. Siehe elektrischer Schaltplan im Handbuch für Installateure. Den Warmwasserfühler (E41.T3) am Einsteckrohr an der Außenseite des Warmwasserbereiters platzieren. Den Fühler in einem Abstand von circa 600 mm (HR200) oder circa 800 mm (HR300) vom Boden des Warmwasserbereiter platzieren. Den Warmwasserfühler an die Leiterplatte im Stromkasten des Innenteils anschließen. Siehe elektrischer Schaltplan im Handbuch für Installateure. Rohr für Warmwasser ([1]) und Kaltwasser ([6]) anschließen. 9 4 5 6 7 Ø 600 Warmwassertemperaturfühler T3 Ist der Warmwasserbereiter angeschlossen und T3 mit dem System verbunden, wird T3 beim Anfahren automatische bestätigt. Warmwasser ist vorrangig und vom Fühler T3 im Warmwasserbereiter gesteuert. Wenn der Bereiter erwärmt ist, wird der Heizbetrieb vorübergehend über ein Wechselventil ausgeschaltet. Ist der Bereiter aufgewärmt, wird der Heizbetrieb von der Wärmepumpe fortgetzt. 6 720 804 927 (2015/07) 6720804927-01.1TL Bild 6 1 2 3 4 5 6 7 8 9 Warmwasserbereiter (mm) Warmwasseraustritt Opferanode Vorlauf Heizwasser Fühlerrohr Rücklauf Heizwasser Kaltwassereintritt Fußschrauben Thermometer Warmwasserzirkulation G3/4" 7 HR 200 & HR 300 Et Paigaldamine 1 2 HOIATUS. Palun üle kontrollida, kas põrand peab vastu raskusele 108 + 200 kg (HR200) või 140 + 300 kg (HR300). Konkreetse süsteemi lahendust ja elektriskeeme sisaldav soojuspumba kasutusjuhend tuleb alati hoida käepärast. 8 ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ HR 200 = 1340, HR 300 = 1797 Kui süsteemiga on ühendatud boiler, tuleb paigaldada automaatne õhueraldi. 3 Kinnitada boileri alla reguleeritavad jalad ([7]). Boiler tuleb paigutada ühetasasele pinnale. Panna boileri külge ümbris/ülakate. Kinnitada boileri küljele termomeeter ([8]). Soojuskandja pealevoolule, otse boileri ([3]) juurde tuleb paigaldada automaatne õhueraldi (E41.F111). Automaatse õhueraldi külge tuleb soojuskandja pealevoolul kinnitada soojuskandja toru ([3]). Torule tuleb paigaldada ventiil (E21.Q21). Soojuspumba siseosale tuleb paigaldada ümberlülitusventiil. Ümberlülitusventiili teisele sissevoolule tuleb paigaldada pealevooluandur (E11.T1). Pealevooluandur peab paiknema ümberlülitusventiilist vähemalt ühe meetri kaugusel. Vt süsteemi joonist, mis on esitatud paigaldusjuhendis. Soojuskandja toru ([5]) tuleb panna soojuskandja tagasivoolukoha külge ja ühendada soojuspumba siseosaga. Ühendada siseosa elektrikilbis ümberlülitusventiili (E21.Q21) ja trükkplaadi elektritoide. Vt elektriskeemi, mis on esitatud paigaldusjuhendis. Paigutada sooja vee andur (E41.T3) sissepandava toru külge, mis paikneb boileri välisküljel. Andur tuleb paigutada umbes 600 mm (HR200) või umbes 800 mm (HR300) kõrgemale boileri põhjast. Sooja vee andur tuleb siseosa elektrikilbis ühendada trükkplaadiga. Vt elektriskeemi, mis on esitatud paigaldusjuhendis. Ühendada sooja vee toru ([1]) ja külma vee toru ([6]). 9 4 5 6 7 Sooja vee temperatuuriandur T3 Ø 600 Kui boiler on ühendatud ja T3 süsteemiga tarkvaraliselt seotud, registreeritakse T3 käivitamisel automaatselt. 6720804927-01.1TL Vee soojendamine on prioriteetne ja seda juhitakse boileris oleva anduri T3 abil. Vee soojendamise ajaks lülitatakse kütmine ümberlülitusventiili abil ajutiselt välja. Kui vesi on boileris soojaks saanud, jätkab soojuspump kütmist. 6 720 804 927 (2015/07) Joon. 7 1 2 3 4 5 6 7 8 9 Boiler (mm) Sooja vee väljavool Kaitseanood Soojuskandja pealevool Anduri asukoht Soojuskandja tagasivool Külma vee sissevool Reguleeritavad jalad Termomeeter Sooja vee ringlus G3/4" 8 HR 200 & HR 300 Nl (Be) Installatie 1 2 WAARSCHUWING: controleer of de vloer een gewicht van 108 + 200 kg (HR200) resp. 140 + 300 kg (HR300) kan dragen. Houd het handboek voor de warmtepomp altijd binnen handbereik, omdat deze actuele systeem-oplossingen en elektrische schakelschema's bevat. 8 ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ HR 200 = 1340, HR 300 = 1797 Breng een automatisch ontluchtingsventiel aan, wanneer een boiler op het systeem wordt aange-sloten. 3 Monteer de stelpoten onder de boiler ([7]). Plaats de boiler op een vlakke ondergrond. Monteer de mantel/kap op de boiler. Monteer de thermometer op de zijkant van de boiler ([8]). Breng een automatische ontluchter (E41.F111) aan op de aanvoer van de warmtedrager, direct op de boiler ([3]). Breng de warmtedragerleiding op de automatische ontluchter op de aanvoer van de warmtedrager aan ([3]). Het ventiel wordt in de leiding ingebouwd (E21.Q21). Monteer het omschakelventiel op het binnenwerk van de warmtepomp. Monteer de aanvoertemperatuursensor (E11.T1) op de andere ingang van het omschakelventiel. Monteer de aanvoertemperatuursensor op minimaal een meter afstand van het omschakelventiel. Zie de systeemoplossing in het handboek voor installateurs. Breng de warmtedragerleiding op de retour van de warmtedrager aan ([5]) en sluit deze aan op het binnenwerk van de warmtepomp. Sluit de voeding aan op het omschakelventiel (E21.Q21) en de printplaat in de aansluitkast van het binnenwerk. Zie het elektrische schakelschema in het handboek voor installateurs. Plaats de warmwatersensor (E41.T3) op de insteekbuis op de buitenzijde van de boiler. Plaats de sensor op een afstand van ca. 600 mm (HR200) of ca. 800 mm (HR300) van de bodem van de boiler. Sluit de warmwatersensor aan op de printplaat in de aansluitkast van het binnenwerk. Zie het elektrische schakelschema in het handboek voor installateurs. Sluit de leidingen voor warmwater ([1]) en koud water ([6]) aan. Warmwater wordt met voorrang en door sensor T3 in de boiler gestuurd. Wanneer de boiler wordt opgewarmd, wordt het cv-bedrijf tijdelijk via een omschakelventiel uitgeschakeld. Wanneer de boiler is opgewarmd, wordt het cv-bedrijf door de warmtepomp voortgezet. 6 720 804 927 (2015/07) 4 5 6 7 Ø 600 Warmwatertemperatuursensor T3 Wanneer de boiler is aangesloten en T3 is met het systeem verbonden, dan wordt T3 bij het starten automatisch bevestigd. 9 6720804927-01.1TL Afb. 8 1 2 3 4 5 6 7 8 9 Boiler (mm) Warmwateruitlaat Opofferingsanode Aanvoer cv-water Sensorleiding Retour cv-water Ingang koud water Instelbare stelpoten Thermometer Warmwatercirculatie G3/4" 9 HR 200 & HR 300 El Εγκατάσταση 1 2 ΠΡΟΕΙΔΟΠΟΙΗΣΗ: Ελέγξτε αν το δάπεδο μπορεί να φέρει βάρος 108 + 200 kg (HR200) ή 140 + 300 kg (HR300). Διατηρείτε το εγχειρίδιο για την αντλία θερμότητας πάντα σε προσιτό σημείο, καθώς περιέχει τρέχουσες λύσεις συστήματος και ηλεκτρολογικά σχέδια. 8 HR 200 = 1340, HR 300 = 1797 Όταν συνδέεται ένα δοχείο ζεστού νερού χρήσης στο σύστημα, πρέπει να τοποθετηθεί μια αυτόματη βαλβίδα εξαέρωσης. ▶ Τοποθετήστε τα ποδαράκια στήριξης κάτω από το δοχείο ζεστού νερού χρήσης ([7]). ▶ Τοποθετήστε το δοχείο ζεστού νερού χρήσης πάνω σε μια επίπεδη βάση. ▶ Τοποθετήστε το περίβλημα/κάλυμμα στο δοχείο ζεστού νερού χρήσης. ▶ Τοποθετήστε το θερμόμετρο στην πλευρά του δοχείου ζεστού νερού χρήσης ([8]). ▶ Τοποθετήστε έναν αυτόματο εξαεριστήρα (E41.F111) στην παροχή του εναλλάκτη, απευθείας στο δοχείο ζεστού νερού χρήσης ([3]). ▶ Τοποθετήστε στην προσαγωγή του εναλλάκτη έναν αυτόματο εξαεριστήρα ([3]). Η βαλβίδα τοποθετείται στη σωλήνωση (E21.Q21). ▶ Τοποθετήστε την τρίοδη βαλβίδα στο εσωτερικό τμήμα της αντλίας θερμότητας. ▶ Τοποθετήστε τον αισθητήρα προσαγωγής (E11.T1) στην άλλη είσοδο της τρίοδης βαλβίδας. Ο αισθητήρας προσαγωγής πρέπει να τοποθετηθεί σε απόσταση τουλάχιστον ενός μέτρου από την τρίοδη βαλβίδα. Βλέπε λύση συστήματος στο εγχειρίδιο για εγκαταστάτες. ▶ Τοποθετήστε το σωλήνα στην επιστροφή του εναλλάκτη ([5]) και συνδέστε τον στο εσωτερικό τμήμα της αντλίας θερμότητας. ▶ Συνδέστε την τροφοδοσία στην τρίοδη βαλβίδα (E21.Q21) και την πλακέτα του κυκλώματος στον ηλεκτρικό πίνακα του εσωτερικού τμήματος. Βλέπε ηλεκτρολογικό σχέδιο στο εγχειρίδιο για εγκαταστάτες. ▶ Τοποθετήστε τον αισθητήρα ζεστού νερού (E41.T3) στο σωλήνα εισαγωγής στην εξωτερική πλευρά του θερμοδοχείου. Τοποθετήστε τον αισθητήρα σε απόσταση περίπου 600 mm (HR200) ή περίπου 800 mm (HR300) από τη βάση του θερμοδοχείου. ▶ Συνδέστε τον αισθητήρα ζεστού νερού με την πλακέτα του κυκλώματος στον πίνακα ελέγχου του εσωτερικού τμήματος. Βλέπε ηλεκτρολογικό σχέδιο στο εγχειρίδιο για εγκαταστάτες. ▶ Συνδέστε το σωλήνα ζεστού νερού ([1]) και κρύου νερού ([6]). Όταν το δοχείο ζεστού νερού χρήσης έχει συνδεθεί και ο αισθητήρας T3 έχει συνδεθεί με το σύστημα, ο αισθητήρας T3 ενεργοποιείται αυτόματα κατά την εκκίνηση. Το ζεστό νερό έχει προτεραιότητα και ελέγχεται από τον αισθητήρα T3 στο θερμοδοχείο. Όταν το θερμοδοχείο έχει θερμανθεί, η λειτουργία θέρμανσης απενεργοποιείται προσωρινά μέσω μιας τρίοδης βαλβίδας. Όταν το θερμοδοχείο έχει προθερμανθεί, η λειτουργία θέρμανσης συνεχίζεται από την αντλία θερμότητας. 6 720 804 927 (2015/07) 9 4 5 6 7 Ø 600 6720804927-01.1TL Σχ. 9 Αισθητήρας θερμοκρασίας ζεστού νερού χρήσης T3 3 1 2 3 4 5 6 7 8 9 Δοχείο ζεστού νερού χρήσης (mm) Έξοδος ζεστού νερού χρήσης Προστασία ανοδίου Προσαγωγή νερού θέρμανσης Σωλήνας αισθητήρα Επιστροφή νερού θέρμανσης Έισοδος κρύου νερού Ποδαράκια στήριξης Θερμόμετρο Aνακυκλοφορία ΖΝΧ G3/4" 10 HR 200 & HR 300 Lv Uzstādīšana 1 2 BRĪDINĀJUMS: Pārbaudiet, vai grīdas nestspēja ir pietiekama 108 + 200 kg (HR200) vai 140 + 300 kg (HR300) svaram. Siltumsūkņa rokasgrāmatai vienmēr ir jāatrodas viegli pieejamā vietā, jo tajā ir iekļauti aktuālie sistēmas risinājumi un elektrisko slēgumu shēmas. 8 ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ HR 200 = 1340, HR 300 = 1797 Ja pie sistēmas tiek pieslēgts karstā ūdens sildītājs (tvertne), nepieciešams uzstādīt automātisku atgaisošanas vārstu. 3 Pieskrūvējiet karstā ūdens tvertnes pamatnes skrūves ([7]). Novietojiet karstā ūdens tvertni uz līdzenas virsmas. Uzlieciet uz karstā ūdens tvertnes apvalku/pārsegu. Piestipriniet termometru pie karstā ūdens tvertnes sānu sienas ([8]). Uzstādiet uz siltumnesēja pievada automātisku atgaisotāju (E41.F111) - tam jāatrodas tieši pie karstā ūdens tvertnes ([3]). Uzlieciet siltumnesēja cauruli uz automātiskā atgaisotāja pie siltumnesēja pievada ([3]). Vārstu iemontē cauruļvadā (E21.Q21). Piemontējiet pārslēgvārstu pie siltumsūkņa iekšējās daļas. Piemontējiet turpgaitas sensoru (E11.T1) pie pārslēgvārsta otras ieejas. Turpgaitas sensoram jābūt uzstādītam ne tuvāk kā vienu metru no pārslēgvārsta. Skatiet sistēmas risinājumu rokasgrāmatā montierim. Pievienojiet siltumnesēja cauruli pie siltumnesēja atgaitas ([5]) un siltumsūkņa iekšējās daļas. Pievienojiet padevi pie pārslēgvārsta (E21.Q21) un pieslēdziet vadības plati iekšējās daļas sadales kārbā. Skatiet elektriskā slēguma shēmu rokasgrāmatā montierim. Novietojiet karstā ūdens sensoru (E41.T3) pie iespraužamās caurules, kas atrodas karstā ūdens tvertnes ārpusē. Novietojiet sensoru apm. 600 mm (HR200) vai apm. 800 mm (HR300) attālumā no karstā ūdens tvertnes pamatnes. Pieslēdziet karstā ūdens sensoru pie vadības plates iekšējās daļas sadales kārbā. Skatiet elektriskā slēguma shēmu rokasgrāmatā montierim. Pieslēdziet karstā ūdens ([1]) un aukstā ūdens ([6]) caurules. 9 4 5 6 7 Ø 600 Karstā ūdens temperatūras sensors T3 Ja karstā ūdens tvertne ir pieslēgta un T3 ir savienots ar sistēmu, ieslēdzot T3 tiek atpazīts automātiski. Karstajam ūdenim ir prioritāte un to vada karstā ūdens tvertnes sensors T3. Karstā ūdens tvertnes uzsilšanas laikā apkures režīms uz brīdi tiek izslēgts ar pārslēgvārsta starpniecību. Siltumsūkņa apkures režīms atkal ieslēdzas, tikko karstā ūdens tvertne ir uzsilusi. 6 720 804 927 (2015/07) 6720804927-01.1TL Att. 10 1 2 3 4 5 6 7 8 9 Karstā ūdens tvertne (mm) Karstā ūdens izeja Aizsarganods Apkures ūdens turpgaita Sensora caurule Apkures ūdens atgaita Aukstā ūdens ieeja Balstskrūves Termometrs Karstā ūdens cirkulācija G3/4" 11 HR 200 & HR 300 Lt Montavimas 1 2 ĮSPĖJIMAS: prašome patikrinti, ar grindys atlaiko 108 + 200 kg (HR200) arba 140 + 300 kg (HR300) svorį. Šilumos siurblio instrukciją visada laikykite pasiekiamoje vietoje, nes joje pateikti aktualūs sistemos sprendimai ir elektrinių sujungimų schemos. 8 ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ HR 200 = 1340, HR 300 = 1797 Jei prie sistemos prijungtas karšto vandens paruošimo įrenginys, reikia primontuoti automatinį oro išleidimo vožtuvą. 3 Po karšto vandens paruošimo įrenginiu prisukite reguliuojamas kojeles ([7]). Karšto vandens paruošimo įrenginį pastatykite ant lygaus pagrindo. Ant karšto vandens paruošimo įrenginio uždėkite apvalkalą ar gaubtą. Prie karšto vandens paruošimo įrenginio šono pritvirtinkite termometrą ([8]). Šilumnešio įvade, tiesiai ant karšto vandens paruošimo įrenginio ([3]) primontuokite automatinį oro išleidimo įtaisą (E41.F111). Prie šilumnešio įvade esančio automatinio oro išleidimo įtaiso ([3]) prijunkite šilumnešio vamzdį. Vožtuvas įmontuojamas vamzdyne (E21.Q21). Šilumos siurblio vidinėje dalyje įmontuokite perjungiamąjį vožtuvą. Kitame perjungiamojo vožtuvo įvade primontuokite tiekiamo srauto jutiklį (E11.T1). Tiekiamo srauto jutiklį primontuoti reikia bent vieno metro atstumu nuo perjungiamojo vožtuvo. Žr. montuotojams skirtoje instrukcijoje pateiktą sistemos sprendimą. Prie šilumnešio grįžtančio srauto linijos pridėkite šilumnešio vamzdį ([5]) ir prijunkite prie šilumos siurblio vidinės dalies. Prie perjungiamojo vožtuvo (E21.Q21) ir valdymo plokštės, esančios vidinės dalies skirstomojoje dėžėje, prijunkite maitinimo liniją. Žr. montuotojams skirtoje instrukcijoje pateiktą elektrinių sujungimų schemą. Prie įstatomojo vamzdžio, esančio karšto vandens paruošimo įrenginio išorinėje pusėje, pritvirtinkite karšto vandens jutiklį (E41.T3). Jutiklį tvirtinkite maždaug 600 mm (HR200) arba 800 mm (HR300) atstumu nuo karšto vandens paruošimo įrenginio pagrindo. Prie valdymo plokštės, esančios vidinės dalies skirstomojoje dėžėje, prijunkite karšto vandens jutiklį. Žr. montuotojams skirtoje instrukcijoje pateiktą elektrinių sujungimų schemą. Prijunkite vamzdį karštam vandeniui ([1]) ir šaltam vandeniui ([6]). 9 4 5 6 7 Ø 600 6720804927-01.1TL Karšto vandens temperatūros jutiklis T3 Kai karšto vandens paruošimo įrenginys yra prijungtas, o T3 sujungtas su sistema, tai T3 paleidimo metu įjungiamas automatiškai. Karšto vandens ruošimas yra prioritetinis, jį valdo karšto vandens paruošimo įrenginyje esantis jutiklis T3. Kai paruošimo įrenginys įšyla, šildymo režimas perjungiamuoju vožtuvu laikinai išjungiamas. Kai paruošimo įrenginys atvėsta, šilumos siurblys vėl pradeda veikti šildymo režimu. 6 720 804 927 (2015/07) Pav. 11 1 2 3 4 5 6 7 8 9 Karšto vandens paruošimo įrenginys (mm) Karšto vandens išvadas Apsauginis anodas Šildymo sistemos vandens tiekiamas srautas Jutiklio vamzdis Šildymo sistemos vandens grįžtantis srautas Šalto vandens įvadas Reguliuojamos kojelės Termometras Karšto vandens cirkuliacija G3/4" 12 HR 200 & HR 300 Pt Instalação 1 2 AVISO: Verifique se o piso suporta um peso de 108 + 200 kg (HR200) ou 140 + 300 kg (HR300) . Mantenha o manual para a bomba de calor sempre acessível, visto que contém soluções de sistemas actuais e esquemas eléctricos. 8 ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ HR 200 = 1340, HR 300 = 1797 Quando um aquecedor de água é ligado ao sistema deve ser colocada uma válvula de purga automática. 3 Colocar os parafusos de nivelamento por baixo do aquecedor de água ([7]). Colocar o aquecedor de água sobre uma superfície plana. Colocar o invólucro/tampa no aquecedor de água. Colocar lateralmente o termómetro do aquecedor de água ([8]). Colocar um purgador automático (E41.F111) na admissão do líquido de calor directamente no aquecedor de água ([3]). Colocar um tubo para líquido de calor no purgador automático na admissão do líquido de calor ([3]). Válvula é montada nos tubos (E21.Q21). Colocar válvula selectora na peça interior da bomba de calor. Colocar sonda de avanço (E11.T1) na outra entrada da válvula selectora. A sonda de avanço deve ser colocada no mínimo um metro afastada da válvula selectora. Ver solução de sistema no manual para instaladores. Colocar o tubo para líquido de calor no tubo de retorno do líquido de calor ([5]) e ligar á peça interior da bomba de calor. Ligar a alimentação da válvula selectora (E21.Q21) e a placa de circuito no quadro eléctrico da peça interior. Ver esquema de circuitos eléctricos no manual para instaladores. Colocar o aquecedor de água (E41.T3) no tubo de encaixe no lado exterior do aquecedor de água. Colocar a sonda numa distância de aprox. 600 mm (HR200) ou aprox. 800 mm (HR300) do piso do aquecedor de água. Ligar o sensor de água quente á placa de circuito impresso no quadro eléctrico da peça interior. Ver esquema de circuitos eléctricos no manual para instaladores. Tubo para água quente ([1]) e água fria ([6]). 9 4 5 6 7 Ø 600 Sensor de temperatura da água quente T3 Se o aquecedor de água quente estiver ligado e T3 conectado com o sistema o T3 é confirmado automaticamente ao arranque. Água quente é prioridade e comandado pelo sensor T3 no aquecedor de água. Quando o aquecedor estiver quente o modo de aquecimento é desligado temporariamente através da válvula selectora. Se o aquecedor estiver quente o modo de aquecimento da bomba de calor continua. 6 720 804 927 (2015/07) 6720804927-01.1TL Fig. 12 1 2 3 4 5 6 7 8 9 Aquecedor de água (mm) Saída de água quente Ânodo de sacrifício Avanço água quente Tubo sonda Tubo de retorno água quente Entrada de água fria Parafusos de nivelamento Termómetro Circulação de água quente G3/4" 13 HR 200 & HR 300 Sk Inštalácia 1 2 VÝSTRAHA: Skontrolujte prosím, či má podlaha nosnosť 108 + 200 kg (HR200) príp. 140 + 300 kg (HR300). Príručku pre tepelné čerpadlo majte vždy po ruke, pretože sú v nej uvedené aktuálne systémové riešenia a schémy el. zapojenia. 8 ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ HR 200 = 1340, HR 300 = 1797 Ak je k systému pripojený zásobníkový ohrievač teplej vody, je nutné nainštalovať automatický odvzdušňovací ventil. 3 Pod zásobníkový ohrievač teplej vody namontujte pätkové skrutky ([7]). Zásobníkový ohrievač teplej vody umiestnite na rovný podklad. Na zásobníkový ohrievač teplej vody namontujte plášť/kryt. Na bočnú stranu zásobníkového ohrievača teplej vody namontujte teplomer ([8]). Na prívode teplonosného média namontujte automatický odvzdušňovací ventil (E41.F111), priamo na zásobníkový ohrievač teplej vody ([3]). Na automatický odvzdušňovací ventil na prívode teplonosného média namontujte potrubie teplonosného média ([3]). Ventil sa montuje do potrubia (E21.Q21). Do vnútornej časti tepelného čerpadla namontujte dvojcestný ventil. Na druhý vstup dvojcestného ventilu namontujte snímač výstupu (E11.T1). Snímač výstupu musí byť namontovaný vo vzdialenosti min. jeden meter od dvojcestného ventilu. Viď systémové riešenie v príručke pre inštalatérov. Namontujte potrubie s teplonosným médiom na spiatočku teplonosného média ([5]) a pripojte ho k vnútornej časti tepelného čerpadla. Napájanie pripojte k dvojcestnému ventilu (E21.Q21) a doske s plošnými spojmi v el. rozvádzači vo vnútornej časti. Viď schému el. zapojenia v príručke pre inštalatérov. Snímač teplej vody (E41.T3) umiestnite do zásuvného potrubia na vonkajšej strane zásobníkového ohrievača teplej vody. Snímač namontujte s odstupom cca. 600 mm (HR200) alebo cca. 800 mm (HR300) od dna zásobníkového ohrievača teplej vody. Pripojte snímač teploty teplej vody k doske s plošnými spojmi v el. rozvádzači vo vnútornej časti. Viď schému el. zapojenia v príručke pre inštalatérov. Pripojte potrubie teplej vody ([1]) a studenej vody ([6]). 9 4 5 6 7 Ø 600 Snímač teploty teplej vody T3 Ak je zásobníkový ohrievač teplej vody pripojený a T3 je prepojený so systémom, tak sa pri nábehu T3 automaticky potvrdí. Teplá voda má prednosť a jej teplotu riadi snímač T3 v zásobníkovom ohrievači teplej vody. Ak je zásobníkový ohrievač teplej vody zohriaty, tak sa vykurovacia prevádzka dočasne vypne pomocou dvojcestného ventilu. Ak je zásobníkový ohrievač teplej vody zohriaty, bude vykurovacia prevádzka pokračovať pomocou tepelného čerpadla. 6 720 804 927 (2015/07) 6720804927-01.1TL Obr. 13 1 2 3 4 5 6 7 8 9 Zásobníkový ohrievač teplej vody (mm) Vývod teplej vody Reakčná anóda Výstup vykurovacej vody Rúrka snímača Spiatočka vykurovacej vody Prívod studenej vody Pätkové skrutky Teplomer Cirkulácia teplej vody G3/4" 14 HR 200 & HR 300 Sl Namestitev 1 2 OPOZORILO: Preverite, ali tla vzdržijo težo 108 + 200 kg (HR200) oz. 140 + 300 kg (HR300). Priročnik za toplotno črpalko imejte vedno na dosegu roke, saj vsebuje aktualne sistemske rešitve in električne vezalne načrte. 8 ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ HR 200 = 1340, HR 300 = 1797 Če se na sistem priključi tudi bojler, je treba namestiti samodejni odzračevalni ventil. 3 Pod bojler namestite nastavljive nogice ([7]). Bojler postavite na ravno podlago. Na bojler namestite plašč/pokrov. Namestite termometer na strani bojlerja ([8]). Samodejni odzračevalnik (E41.F111) namestite neposredno na vstopu ogrevalnega voda v bojler ([3]). Cev ogrevalnega voda priključite na samodejni odzračevalnik na dotoku medija ([3]). Ventil se vgradi v cevovod (E21.Q21). Preklopni ventil namestite v notranjo enoto toplotne črpalke. Tipalo dvižnega voda (E11.T1) namestite na cevi na drugem vhodu v preklopni ventil. Tipalo naj bo nameščeno vsaj en meter od preklopnega ventila. Glej sistemske rešitve v navodilu za montažo. Povratni vod izmenjevalca toplote priključite na notranjo enoto toplotne črpalke ([5]). Napajanje preklopnega ventila (E21.Q21) priključite na električni stikalni omarici v notranji enoti toplotne črpalke. Glej električni vezalni načrt v navodilu za montažo. Tipalo za toplo vodo (E41.T3) namestite v potopno tulko na zunanji strani bojlerja. Tipalo namestite v razdalji približno 600 mm (HR200) ali približno 800 mm (HR300) od tal. Tipalo za toplo vodo priključite na glavno ploščo v stikalni omarici notranje enote toplotne črpalke. Glej električni vezalni načrt v navodilu za montažo. Priključite cev za toplo vodo ([1]) in hladno vodo ([6]). 9 4 5 6 7 Ø 600 Temperaturno tipalo za toplo vodo T3 Ko je bojler za sanitarno vodo priključen in T3 povezan s sistemom, se T3 ob zagonu samodejno potrdi. Topla voda je na voljo in jo krmili tipalo T3 bojlerja. Ko je sanitarna voda v bojlerju ogreta na nastavljeno temperaturo, se ogrevanje prek preklopnega ventila začasno izklopi. Ko je voda v bojlerju segreta, toplotna črpalka nadaljuje z ogrevanjem centralnega sistema, v kolikor je to potrebno. 6 720 804 927 (2015/07) 6720804927-01.1TL Sl. 14 1 2 3 4 5 6 7 8 9 Bojler za sanitarno vodo (mm) Izstop tople vode Anoda Ogrevalni vod Potopna tulka Povratni vod Vstop hladne vode Nastavljive noge Termometer Cirkulacija tople vode G3/4" 15 HR 200 & HR 300 Cs Instalace 1 2 VÝSTRAHA: Zkontrolujte, zda podlaha unese hmotnost 108 + 200 kg (HR200) popř. 140 + 300 kg (HR300). Příručku pro tepelné čerpadlo mějte vždy po ruce, protože jsou v ní obsažena aktuální systémová řešení a elektrická schémata zapojení. 8 ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ HR 200 = 1340, HR 300 = 1797 Pokud se zařízení na přípravu teplé vody připojuje na systém, je nutné namontovat automatický odvzdušňovací ventil. 3 Stavěcí šrouby namontujte pod ohřívač teplé vody ([7]). Ohřívač teplé vody postavte na rovný podklad. Na ohřívač teplé vody instalujte obal/kryt. Na bok ohřívače připevněte teploměr ([8]). Na přítok teplonosné látky, přímo na ohřívač teplé vody, namontujte automatický odvzdušňovač (E41.F111) ([3]). Na přívodní potrubí nositele tepla instalujte automatický odvzdušňovač ([3]). Ventil se montuje do potrubí (E21.Q21). Přepínací ventil namontujte na vnitřní jednotku tepelného čerpadla. Čidlo výstupní teploty (E11.T1) umístěte na druhém vstupu přepínacího ventilu. Čidlo výstupní teploty musí být umístěno ve vzdálenosti alespoň jeden metr od přepínacího ventilu. Viz systémové řešení v příručce pro instalatéry. Potrubí teplonosné látky připojte na zpátečku teplonosné látky ([5]) a na vnitřní jednotku tepelného čerpadla. Napájení připojte na přepínací ventil (E21.Q21) a na řídicí desku v rozváděči vnitřní jednotky. Viz elektrické schéma zapojení v příručce pro instalatéry. Čidlo teplé vody (E41.T3) umístěte do jímky na vnější straně ohřívače teplé vody. Čidlo umístěte ve vzdálenosti asi 600 mm (HR200) nebo asi 800 mm (HR300) ode dna ohřívače teplé vody. Čidlo teplé vody připojte na řídicí desku v rozváděči vnitřní jednotky. Viz elektrické schéma zapojení v příručce pro instalatéry. Připojte trubku pro teplou vodu ([1]) a pro studenou vodu ([6]). 9 4 5 6 7 Čidlo výstupní teploty teplé vody T3 Ø 600 Je-li ohřívač teplé vody připojen a čidlo T3 spojeno se systémem, dojde při ohřevu k automatickému potvrzení čidla T3. 6720804927-01.1TL Teplá voda má přednost a je řízena čidlem T3 v ohřívači teplé vody. Je-li akumulační zásobník ohřívající teplou vodu zahřátý, vypne se na přechodnou dobu přepínací ventil pro vytápění. Ohřívá-li se akumulační zásobník, pokračuje také tepelné čerpadlo v provozu vytápění. 6 720 804 927 (2015/07) Obr. 15 1 2 3 4 5 6 7 8 9 Ohřívač teplé vody (mm) Výstup teplé vody Obětní (degradační) anoda Výstup otopná voda Trubka čidla Zpátečka otopná voda Vstup studené vody Stavěcí šrouby Teploměr Cirkulace teplé vody G3/4" 16 HR 200 & HR 300 NL Installatie 1 2 WAARSCHWUWING: controleer of de vloer een gewicht van 108 + 200 kg (HR200) resp. 140 + 300 kg (HR300) kan dragen. Houd de installatie-instructie van de warmtepomp altijd binnen handbereik, omdat deze actuele systeemoplossingen en elektrische schakelschema's bevat. 8 ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ HR 200 = 1340, HR 300 = 1797 Breng een automatisch ontluchtingsventiel aan, wanneer een boiler op het systeem wordt aangesloten. 3 Monteer de stelpoten onder de boiler ([7]). Plaats de boiler op een vlakke ondergrond. Monteer de mantel/kap op de boiler. Monteer de thermometer op de zijkant van de boiler ([8]). Monteer de cv-aanvoerleiding tussen de binnenunit van de warmtepomp en de boiler ([3]). Plaats een driewegklep en een automatische ontluchter in de cvaanvoerleiding. Plaats de ontluchter zo dicht mogelijk bij het aansluitpunt op de boiler (E21.Q21). Sluit de driewegklep aan op de printplaat in de binnenunit. Monteer de aanvoertemperatuursensor (E11.T1) op de cv-aanvoerleiding tussen de binnenunit en de driewegklep. Plaats de sensor op minimaal 1 meter afstand van de driewegklep. Zie voor de hydraulische aansluitschema's de installatie instructie van de warmtepomp. Monteer de cv-retourleiding tussen de cv -retouraansluiting van de boiler ([5]) en de cv- retouraansluiting van de binnenunit. Sluit de voedingspanning van de driewegklep (E21.Q21) aan op de printkaart in de binnenunit. Zie de elektrische aansluitschema's in de installatie-instructie van de warmtepomp. Plaats de boilersensor (E41.T3) in de dompelbuis op ca. 600mm (HR200) of ca. 800mm (HR300) van de bodem van de boiler. Sluit de boilersensor aan op de printplaat in de binnenunit. Zie de elektrische aanluitschema's in de installatie-instructie van de warmtepomp. Sluit de leidingen voor warmwater ([1]) en koud water ([6]) aan. 6 7 Ø 600 Wanneer de boiler is aangesloten en boilersensor T3 is met de binnenunit verbonden, dan wordt boilersensor T3 bij het starten automatisch bevestigd. 6 720 804 927 (2015/07) 4 5 Boilersensor T3 De bereiding van warmwater heeft voorrang op het cv-bedrijf.. Wanneer de boiler wordt opgewarmd, wordt het cv-bedrijf tijdelijk via de driewegklep uitgeschakeld. Wanneer de boiler is opgewarmd, wordt het cv-bedrijf door de warmtepomp voortgezet. 9 6720804927-01.1TL Afb. 16 1 2 3 4 5 6 7 8 9 Boiler (mm) Warmwateruitlaat Opofferingsanode Aanvoer cv-water Dompelbuis Retour cv-water Ingang koud tapwater Instelbare stelpoten Thermometer Warmwatercirculatie G3/4" 17 HR 200 & HR 300 Es Instalación 1 2 ADVERTENCIA: compruebe si el suelo soporta un peso de 108 + 200 kg (HR200) o 140 + 300 kg (HR300). Tenga siempre al alcance el manual de la bomba de calefacción ya que contiene soluciones del sistema y esquemas de conexión eléctrica actuales. 8 ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ HR 200 = 1340, HR 300 = 1797 Cuando un calentador de agua se conecta al sistema, debe instalarse una válvula automática de purga de aire. 3 Colocar los tornillos niveladores bajo el calentador de agua ([7]). Colocar el calentador de agua sobre una base plana. Instalar la cubierta/capota en el calentador de agua. Instalar el termómetro en el lado del calentador de agua ([8]). Instalar un purgador automático (E41F111) sobre la alimentación del caloportador, directamente en el calentador de agua ([3]). Colocar la tubería del caloportador sobre el purgador automático en la alimentación del caloportador ([3]). Se monta la válvula en la tubería (E21.Q21). Instalar la válvula de doble paso en la parte interior de la bomba de calefacción. Instalar el sensor de avance (E11.T1) en la otra entrada de la válvula de doble paso. El sensor de avance debe instalarse como mínimo a un metro de la válvula de doble paso. Véase en las soluciones del sistema del manual para instaladores. Colocar la tubería del caloportador en el retorno del caloportador ([5]) y conectar esta a la parte interior de la bomba de calefacción. Conectar la alimentación a la válvula de doble paso (E21.Q21) y la placa electrónica en el cuadro eléctrico de la parte interior. Véase el esquema de conexión eléctrica en el manual para instaladores. Colocar el sensor de agua caliente (E41.T3) en la tubería de inserción en la parte exterior del calentador de agua. Colocar el sensor a una distancia de aprox. 600 mm (HR200) o de aprox. 800 mm (HR300) de la base del calentador de agua. Conectar el sensor de agua caliente a la placa electrónica en el cuadro eléctrico de la parte interior. Véase el esquema de conexión eléctrica en el manual para instaladores. Conectar el tubo para el agua caliente ([1]) y el agua fría ([6]). 9 4 5 6 7 Ø 600 Sensor de temperatura de agua caliente T3 Una vez esté conectado el calentador de agua y T3 con el sistema, al arrancar se confirma automáticamente T3. El agua caliente tiene prioridad y es controlada por el sensor T3 en el calentador de agua. Cuando el calentador esté calentado, a través de una válvula de doble paso se desconecta temporalmente el funcionamiento de la calefacción. Una vez el calentador se haya recalentado, se prolonga el funcionamiento de la calefacción por la bomba de calefacción. 6 720 804 927 (2015/07) 6720804927-01.1TL Fig. 17 1 2 3 4 5 6 7 8 9 Calentador de agua (mm) Salida de agua caliente Ánodo protector Avance del agua de calefacción Tubería con sensor Retorno del agua de calefacción Entrada del agua fría Tornillos niveladores Termómetro Circulación del agua caliente G3/4" 18 HR 200 & HR 300 Ru Монтаж 1 2 ПРЕДУПРЕЖДЕНИЕ: Проверьте, выдержит ли пол вес 108 + 200 кг (HR200) и 140 + 300 кг (HR300). Держите всегда под рукой руководство по тепловым насосам, так как оно содержит актуальные системные решения и электросхемы. 8 ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ HR 200 = 1340, HR 300 = 1797 Если к системе подключен водонагреватель, то нужно установить автоматический воздухоотводчик. 3 Установите опорные ножки под водонагревателем ([7]). Поставьте водонагреватель на ровную поверхность. Установите крышку/кожух на водонагреватель. Установите термометр на стороне водонагревателя ([8]). Установите автоматический воздухоотводчик (E41.F111) на подаче теплоносителя непосредственно на водонагревателе ([3]). Установите трубу теплоносителя на автоматическом воздухоотводчике на подаче теплоносителя ([3]). Воздухоотводчик монтируется в трубопровод (E21.Q21). Установите переключающий клапан на внутренней части теплового насоса. Установите датчик подающей линии (E11.T1) на другом входе переключающего клапана. Датчик подающей линии должен находиться на расстоянии не менее одного метра от переключающего клапана. См. системное решение в руководстве для монтажников. Установите трубу теплоносителя на обратной линии ([5]) и подключите внутреннюю часть теплообменника. Подключите питание к переключающему клапану (E21.Q21) и электронной плате в электрошкафу внутренней части. См. электросхему в руководстве для монтажников. Разместите датчик горячей воды (E41.T3) на вставной трубе на наружной части водонагревателя. Разместите датчик на расстоянии около 600 мм (HR200) или около 800 мм (HR300) от дна водонагревателя. Подключите датчик горячей воды к электронной плате в электрошкафу внутренней части. См. электросхему в руководстве для монтажников. Подключите трубу горячей ([1]) и холодной ([6]) воды. 9 4 5 6 7 Ø 600 Датчик температуры горячей воды T3 Если подключен водонагреватель, и T3 соединён с системой, то T3 автоматически подтверждается при пуске. Горячая вода имеет приоритет, и управление осуществляется от датчика T3 в водонагревателе. Если водонагреватель нагрет, то режим нагрева временно выключается переключающим клапаном. Если водонагреватель не нагрет до заданной температуры, то режим нагрева продолжается от теплового насоса. 6 720 804 927 (2015/07) 6720804927-01.1TL Рис. 18 1 2 3 4 5 6 7 8 9 Водонагреватель (мм) Выход горячей воды Анод протекторной защиты Подающая линия греющей воды Трубка датчика Обратная линия греющей воды Вход холодной воды Опорные болты Термометр Циркуляция горячей воды G3/4" 19 HR 200 & HR 300 No Installasjon 1 2 ADVARSEL: Kontroller at gulvet er dimensjonert for vekten108 + 200 kg (HR 200) eller 140 + 300 kg (HR 300). Ha installatørhåndboken til varmepumpen tilgjengelig, ettersom den inneholder aktuelle systemløsninger og koblingsskjema. 8 ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ HR 200 = 1340, HR 300 = 1797 En automatisk avluftningsventil må monteres da en varmtvannsbereder kobles til systemet. 3 Monter justeringsføttene på varmtvannsberederen ([7]). Plasser varmtvannsberederen på et flatt underlag. Monter en kappe på varmtvannsberederen. Monter termometeret på siden av varmtvannsberederen ([8]). Monter en automatisk avlufter (E41.F111) på varmtvannsberederens inntak rett ved berederen ([3]). Monter varmebærerrør til varmtvannsberederens inntak på den automatiske avlufteren ([3]). Deretter monteres vekselventil (E21.Q21) på røret. Koble vekselsventilen til varmepumpens innedel. Monter fremledningsgiver (E11.T1) på vekselventilens andre inngang. Fremledningsgiveren skal monteres minst en meter fra vekselventilen. Se systemløsningen i installatørhåndboken til varmepumpen. Monter varmebærererør til varmtvannsberederens uttak ([5]) og koble til varmepumpens innedel. Koble strømtilførselen til vekselventilen (E21.Q21) til kretskortet i innedelens koblingsboks. Se elektrisk koblingsskjema i installatørhåndboken til varmepumpen. Plasser varmtvannsføleren (E41.T3) i innstikksrøret på utsiden av varmtvannsberederen([4]). Føleren plasseres ca. 600 mm (HR200) eller ca. 800 mm (HR300) fra bunnen av tanken. Koble varmtvannsføleren til kretskortet i innedelens koblingsboks. Se elektrisk koblingsskjema i installatørhåndboken til varmepumpen. Anslutt rørene for varmtvann ([1]) og kaldvann ([6]). 9 4 5 6 7 Ø 600 Varmtvannsføler T3 Hvis varmtvannsbereder er tilkoblet og T3 er koblet til systemet, autokvitteres T3 ved oppstart. Varmtvannet prioriteres og styres av føleren T3 i varmtvannsberederen. Når berederen varmes, kobles varmedriften fra varmepumpen midlertidig bort via vekselventilen. Når vannet i berederen har nådd sin innstilte temeperatur, fortsetter varmedriften fra varmepumpen. 6720804927-01.1TL Fig. 19 1 2 3 4 5 6 7 8 9 Varmtvannsbereder (mm) Varmtvann ut Offeranode Varmebærer inn Plassering av følere Varmebærer ut Kaldtvann inn Justeringsføtter Termometer Varmtvannssirkulasjon G3/4" H x D: HR 200 = 1340 x 600 mm, HR 300 = 1797 x 600 mm 6 720 804 927 (2015/07) 20 HR 200 & HR 300 Pl Instalacja 1 2 OSTRZEŻENIE: należy się upewnić, że podłoże wytrzyma obciążenie 108 + 200 kg (HR200) lub 140 + 300 kg (HR300). Instrukcję instalacji do pompy ciepła należy przechowywać zawsze w miejscu łatwo dostępnym, gdyż są w nim podane rozwiązania systemowe oraz schematy elektryczne połączeń. 8 ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ HR 200 = 1340, HR 300 = 1797 Przy podłączaniu podgrzewacza pojemnościowego c.w.u. do systemu należy zamontować automatyczny zawór odpowietrzający. Śruby poziomujące wkręcić pod podgrzewacz c.w.u. ([7]). Podgrzewacz c.w.u. ustawić na równym podłożu. Osłonę/pokrywę umieścić na podgrzewaczu c.w.u. Termometr umieścić z boku podgrzewacza c.w.u. ([8]). Odpowietrznik automatyczny (E41.F111) zamontować na wejściu czynnika grzewczego do podgrzewacza c.w.u. ([3]). Rurę nośnika ciepła zamontować na odpowietrzniku automatycznym, na dopływie nośnika ciepła ([3]). Zawór jest montowany w przewodzie rurowym (E21.Q21). Przełącznik obiegu (zawór 3-drogowy) umieścić na wewnętrznej części pompy ciepła. Czujnik temperatury zasilania (E11.T1) zamontować na innym wejściu przełącznika obiegu. Czujnik temperatury zasilania musi zostać zamontowany w minimalnym odstępnie od przełącznika obiegu wynoszącym jeden metr. Patrz Rozwiązanie systemowe w instrukcji pompy ciepła dla instalatorów. Rurę nośnika ciepła zamontować na powrocie nośnika ciepła ([5]) i podłączyć do wewnętrznej części pompy ciepła. Zasilanie podłączyć do przełącznika obiegu (E21.Q21) oraz płyty głównej w skrzynce prądowej części wewnętrznej. Patrz Elektryczny schemat podłączenia w podręczniku dla instalatorów. Czujnik temperatury ciepłej wody (E41.T3) umieścić na rurze wtykowej po zewnętrznej stronie podgrzewacza c.w.u. Czujnik umieścić w odległości około 600 mm (HR200) lub około 800 mm (HR300) od podłoża, na którym umieszczony został podgrzewacz c.w.u. Czujnik temperatury ciepłej wody podłączyć do płyty głównej w skrzynce prądowej części wewnętrznej. Patrz Elektryczny schemat podłączenia w podręczniku dla instalatorów. Podłączyć rurę wody ciepłej ([1]) i rurę wody zimnej ([6]). Jeśli podgrzewacz c.w.u. jest podłączony i T3 jest połączony z systemem, T3 jest potwierdzany automatycznie podczas uruchomienia. Przygotowanie c.w.u. jest priorytetowe i sterowane przez czujnik T3 w podgrzewaczu c.w.u. Podczas nagrzewania pogrzewacza tryb grzania jest wyłączany przez przełącznik obiegu. Po nagrzaniu podgrzewacza pojemnościowego pompa ciepła kontynuuje tryb grzania (c.o.) Dane techniczne HR200/HR300 Pojemność użytkowa Powierzchnia wymiany ciepła Znamionowa liczba mocy NL Straty postojowe Dopuszczalne ciśnienie robocze (c.o.) Dopuszczalne ciśnienie robocze (c.w.u.) Masa netto 6 720 804 927 (2015/07) 9 4 5 6 7 Ø 600 6720804927-01.1TL Rys. 20 Czujnik temperatury c.w.u. T3 3 1 2 3 4 5 6 7 8 9 Podgrzewacz c.w.u. (mm) Wypływ ciepłej wody G1" Anoda reakcyjna G5/4" Zasilanie wody grzewczej G1" Rurka czujnika Powrót wody grzewczej G1" Dopływ wody zimnej G1" Nóżki śrubowe poziomujące Termometr Cyrkulacja c.w.u. G3/4" 200/300 [l] 1,8/2,6 [m2] 1,8/2,3 1,8/2,2 [kWh/d] 10 [bar] 10 [bar] 105/138 [kg] 21 HR 200 & HR 300 [de] Wichtige Hinweise zur Installation/Montage [lv] Svarīgi norādījumi par iekārtas uzstādīšanu / montāžu Die Installation/Montage muss durch eine für die Arbeiten zugelassene Fachkraft unter Beachtung der geltenden Vorschriften erfolgen. Iekārtas uzstādīšanu/montāžu ir jāveic specializētam sertificētam speciālistam, ievērojot spēkā esošos noteikumus. ▶ Mitgeltende Anleitungen von Anlagenkomponenten, Zubehören und Ersatzteilen beachten. ▶ Vor allen Arbeiten: Anlage allpolig spannungsfrei machen. ▶ Ievērojiet iekārtas komponentu, piederumu un rezerves daļu instrukcijas. ▶ Pirms jebkādu darbu uzsākšanas: izslēdziet iekārtas strāvas padevi visiem poliem. [en] Important notes on installation/assembly [nl] Belangrijke aanwijzingen betreffende de installatie/montage The installation/assembly must be carried out by a professional who is authorised to do the work, and with due regard to the relevant regulations. De installatie/montage moet worden uitgevoerd door een voor de werkzaamheden geautoriseerde installateur rekening houdend met de geldende voorschriften. ▶ Observe all the relevant instructions for other system components, accessories and spare parts. ▶ Before starting any work: disconnect the system from the power supply across all phases. ▶ Respecteer tevens geldende handleidingen van installatiecomponenten, toebehoren en reserveonderdelen. ▶ Voor alle werkzaamheden: installatie over alle polen spanningsloos schakelen. [pt] Indicações importantes relativas à instalação/montagem [fr] Instructions importantes pour l’installation/le montage L’installation/le montage doit être effectué(e) par un spécialiste qualifié pour les opérations concernées et dans le respect des prescriptions applicables. ▶ Respecter également les notices des composants de l’installation, des accessoires et des pièces de rechange. ▶ Avant tous les travaux : couper la tension sur tous les pôles de l’installation. A instalação/montagem deve ser efectuada por um técnico especializado com qualificações para estes trabalhos, tendo em atenção os regulamentos em vigor. ▶ Ter em consideração as instruções aplicáveis de componentes da instalação, acessórios e peças de substituição. ▶ Antes de todos os trabalhos: desligar a instalação da corrente em todos os pólos. [ru] Важные указания по подключению/монтажу [cs] Důležité pokyny k instalaci/montáži Instalaci/montáž musí při dodržení platných předpisů provést odborný pracovník s příslušným oprávněním pro tyto práce. Подключение/монтаж должны выполнять специалисты, имеющие допуск к выполнению таких работ, при соблюдении действующих норм и правил. ▶ Řiďte se souvisejícími návody pro komponenty zařízení, příslušenství a náhradní díly. ▶ Před započetím všech prací: vypněte kompletně napájení do zařízení. ▶ Выполняйте требования сопутствующих инструкций на компоненты установки, дополнительное оборудование и запчасти. ▶ Перед выполнением любых работ: обесточьте установку отключением всех фаз. [el] Σημαντικές υποδείξεις για την εγκατάσταση/συναρμολόγηση [sk] Dôležité pokyny týkajúce sa inštalácie/montáže Η εγκατάσταση/συναρμολόγηση πρέπει να πραγματοποιείται από εξουσιοδοτημένο για τις εργασίες αυτές τεχνικό προσωπικό, το οποίο θα πρέπει να φροντίζει ώστε να τηρούνται οι ισχύουσες διατάξεις. Inštaláciu/montáž musí realizovať odborník s oprávnením na výkon týchto prác, pričom musí dodržovať platné predpisy. ▶ Λάβετε υπόψη τις συνοδευτικές οδηγίες που αφορούν τα εξαρτήματα της εγκατάστασης, τους πρόσθετους εξοπλισμούς και τα ανταλλακτικά. ▶ Πριν από οποιαδήποτε εργασία: Αποσυνδέστε όλους τους πόλους της εγκατάστασης από το ρεύμα. [es] Indicaciones importantes para instalación/montaje La instalación/el montaje lo debe realizar personal especializado autorizado para los trabajos, respetando las prescripciones vigentes. ▶ Respetar las instrucciones de referencia de los componentes de la instalación, los accesorios y las piezas de repuesto. ▶ Antes de todos los trabajos: eliminar la tensión en todos los polos de la instalación. [et] Olulised juhised paigaldamiseks/montaažiks ▶ Dodržujte inštrukcie uvedené v súvisiacich návodoch ku komponentom zariadenia, príslušenstvu a náhradným dielom. ▶ Pred začiatkom všetkých prác: Odpojte všetky póly el. napájania zariadenia. [sl] Pomembni napotki za namestitev/montažo Namestitev/montažo mora izvesti strokovnjak, pristojen za tovrstna dela, ob upoštevanju veljavnih predpisov. ▶ Upoštevajte priložena veljavna navodila komponent naprave, priborov in nadomestnih delov. ▶ Pred vsemi deli: izklopite napravo iz vseh polov. [sv] Viktiga anvisningar för installation/montering Installationen/monteringen måste utföras av en behörig och fackkunnig person enligt gällande föreskrifter. Paigaldamist/montaaži tohib läbi viia selleks volitusi omav spetsialist, arvestades kehtivaid nõudeid. ▶ Tillämpliga instruktioner för systemkomponenter, tillbehör och reservdelar ska också följas. ▶ Före alla arbeten ska anläggningen försättas i spänningsfritt tillstånd. ▶ Tuleb järgida kõiki seadme komponentide, tarvikute ja varuosade kohta kaaskehtivaid juhendeid. ▶ Enne kõigi tööde alustamist: muuta seadme kõik faasid pingevabaks. [tr] Kurulum/Montaj ile ilgili önemli uyarılar [it] Avvertenze importanti per l'installazione/il montaggio L'installazione/il montaggio deve aver luogo ad opera di una ditta specializzata ed autorizzata in osservanza delle disposizioni vigenti. ▶ Osservare le istruzioni allegate dei componenti dell'impianto, degli accessori e delle parti di ricambio. ▶ Prima di tutti i lavori: staccare completamente l'alimentazione elettrica dell'impianto. [lt] Svarbios instaliavimo ir (arba) montavimo nuorodos Instaliuoti ir montuoti, laikantis galiojančių taisyklių, leidžiama kvalifikuotiems specialistams, kurie buvo įgalioti šiems darbams atlikti. Kurulum/Montaj çalışmaları sadece yetkili bayiler tarafından aşağıda belirtilen talimatlar dikkate alınarak yapılmalıdır. ▶ Tesisat parçalarına, aksesuarlara ve yedek parçalara ait talimatları dikkate alın. ▶ Çalışmaya başlamadan önce: Enerji beslemesinin tüm kutuplarını ayırarak tesisatın enerji beslemesini kesin. [pl] Ważne wskazówki dotyczące instalacji/montażu Instalację/montaż powinien wykonać specjalista uprawniony do tego typu prac z uwzględnieniem aktualnie obowiązujących przepisów. ▶ Przestrzegać dodatkowych instrukcji dołączonych do części instalacji, osprzętu dodatkowego oraz części zamiennych. ▶ Przed przystąpieniem do wykonywania wszelkich prac: odłączyć instalację od zasilania sieciowego (wszystkie bieguny). ▶ Taip pat laikykitės įrenginio komponentų, priedų ir atsarginių dalių galiojančių instrukcijų. ▶ Prieš pradėdami bet kokius darbus: atjunkite įrenginio visų fazių srovę. 6 720 804 927 (2015/07) 22 HR 200 & HR 300 6 720 804 927 (2015/07) 23 Bosch Thermotechnik GmbH Sophienstraße 30-32 D-35576 Wetzlar/Germany
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Buderus HR 200 Installation Instructions Manual

Type
Installation Instructions Manual
Deze handleiding is ook geschikt voor

in andere talen