EasyHOME HYGRO - humidity-controlled exhaust ventilation
EasyHOME HYGRO Premium MW, SP, HP, HP+ EN
Supplier brand Aldes Aldes Aldes Aldes
Designation EasyHOME HYGRO
Premium MW
EasyHOME HYGRO
Premium SP
EasyHOME HYGRO
Premium HP
EasyHOME HYGRO
Premium HP+
Energy class - Average climate BBBB
Average climate - SEC - Specific energy consumption (kWh/(m2
a year) -26,73 -26,99 -26,08 -26,55
Cold climate - SEC - Specific energy consumption (kWh/(m2 a
year) -53,79 -53,52 -53,14 -52,90
Warm climate - SEC - Specific energy consumption (kWh/(m2 a
year) -11,22 -10,95 -10,58 -10,33
Type of airflow SF SF SF SF
Declared type UVR UVR UVR UVR
Type of motor installed or planned 4/ Variable speed 4/ Variable speed 4/ Variable speed 4/ Variable speed
Type of heat recovery system N/A N/A N/A N/A
Thermal efficiency of heat recovery (%) N/A N/A N/A N/A
Maximum RVU (m3/h) 298 418 333 351
Electric power absorbed at Qmax (W) 41,4 73,2 45,5 46,5
LwA - Sound power level (dB) 49 53 49 52
Reference airflow (m3/s) 0,060 0,080 0,060 0,070
Difference in reference pressure (Pa) 147 55 137 172
SPI (W/(m3/h) 0,12 0,10 0,12 0,13
Control factor (%) 0,65 0,65 0,65 0,55
Type of control system Local Demand Control Local Demand Control Local Demand Control Local Demand Control
Maximum declared internal leakage rate under negative pressure
for BVU (%) N/A N/A N/A N/A
Maximum declared external leakage rate under negative pressure
for UVU and BVU (%) 4,3 3 3,8 3,6
Maximum declared internal leakage rate under positive pressure
for BVU (%) N/A N/A N/A N/A
Maximum declared external leakage rate under positive pressure
for UVU and BVU (%) N/A N/A N/A N/A
Mixing rate for standalone BVU without branch connections (%) N/A N/A N/A N/A
Position of visual alarm N/A N/A N/A N/A
Description of visual alarm N/A N/A N/A N/A
Regular replacement of filters to ensure unit performance and
energy efficiency N/A N/A N/A N/A
Instructions for installation of fresh air inlets Cf. Notice Cf. Notice Cf. Notice Cf. Notice
Sensitivity of airflow to pressure variations at +20 Pa N/A N/A N/A N/A
Sensitivity of airflow to pressure variations at -20 Pa N/A N/A N/A N/A
Indoor/outdoor air tightness (m3/h) N/A N/A N/A N/A
Annual electricity consumption (kWh electricity/a year) 63 52 89 70
Average climate - AHS - Annual heating savings
(kWh primary energy/a year) 2830 2830 2830 2830
Cold climate - AHS - Annual heating savings (kWh primary
energy/a year) 5536 5536 5536 5536
Warm climate - AHS - Annual heating savings (kWh primary
energy/a year) 1280 1280 1280 1280