Samlexpower PSC1800-24-35 de handleiding

Categorie
Stroomgeneratoren
Type
de handleiding

Deze handleiding is ook geschikt voor

PSC1600-12-60
PSC2000-12-80
PSC3000-12-120
PSC1800-24-35
PSC2500-24-50
PSC3500-24-70
Model No.
SINEWAVE INVERTER-CHARGER
Manual, Gebruiksaanwijzing, Benutzerhandbuch,
Manuel Utilisateur, Manual Para Utilizador
Please read this manual before operating your inverter-charger
Sinewave inverter-charger
Powersine Combi
1
Notice of Copyright
Powersine Combi PSC1600-3500 inverter/charger owner’s manual © 2012-2014 Samlex
Europe BV. All rights reserved. No part of this document may be reproduced in any form or
disclosed to third parties without the express written permission of Samlex Europe BV, Aris
van Broekweg15, 1507 BA ZAANDAM, The Netherlands. Samlex Europe BV reserves the right
to revise this document and to periodically make changes to the content hereof without
obligation or organization of such revisions or changes, unless required to do so by prior
arrangement.
Exclusions for documentation and product usage
UNLESS SPECIFICALLY AGREED TO IN WRITING, SAMLEX EUROPE BV (“SAMLEX”) :
1. MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY OF ANY
TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER
DOCUMENTATION
2. ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSSES, DAMAGES, COSTS OR EXPENSES,
WHETHER SPECIAL, DIRECT, INDIRECT, CONSEQUENTIAL OR INCIDENTAL, WHICH MIGHT
ARISE OUT OF THE USE OF SUCH INFORMATION. THE USE OF ANY SUCH INFORMATION
WILL BE ENTIRELY AT THE USER’S RISK
3. REMINDS YOU THAT IF THIS MANUAL IS IN ANY LANGUAGE OTHER THAN ENGLISH OR
DUTCH, ALTHOUGH STEPS HAVE BEEN TAKEN TO MAINTAIN THE ACCURACY OF THE
TRANSLATION, THE ACCURACY CANNOT BE GUARANTEED.
4. MAKES NO WARRANTY, EITHER EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED
TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE, REGARDING THESE SAMLEX PRODUCTS AND MAKES SUCH SAMLEX PRODUCTS
AVAILABLE SOLELY ON AN “AS IS” BASIS.
5. SHALL IN NO EVENT BE LIABLE TO ANYONE FOR SPECIAL, COLLATERAL, INCIDENTAL, OR
CONSEQUENTIAL DAMAGES IN CONNECTION WITH OR ARISING OUT OF PURCHASE OR
USE OF THESE SAMLEX PRODUCTS. THE SOLE AND EXCLUSIVE LIABILITY TO
SAMLEX,REGARDLESS OF THE FORM OF ACTION, SHALL NOT EXCEED THE PURCHASE
PRICE OF THE SAMLEX PRODUCTS DESCRIBED HERE IN.
Document name, date and part number
Samlex PSC1600-3500 Manual Rev1endfs”, January 2014, 201183
Powersine Combi
27
9. DECLARATION OF CONFORMITY
IMPORTER : Samlex Europe B.V.
ADDRESS : Aris van Broekweg 15
1507 BA ZAANDAM
The Netherlands
Declares that the following products :
PRODUCT TYPE : Professional inverter / charger combination
MODELS : PSC1600-12-60, PSC1800-24-35, PSC2000-12-80, PSC2500-24-50,
PSC3000-12-120, PSC3500-24-70
Conforms to the requirements of the following Directives of the European Union :
EMC Directive 2004/108/EC
The above product is in conformity with the following harmonized standards :
Low Voltage Directive 2006/95/EC
EN61000-6-3 : 2001 EMC - Generic Emissions Standard
EN61000-6-2 : 2005 EMC - Generic Immunity Standard
EN60335-1 : 1999 Generic safety standard
EN60335-2-29 : 2004 Safety requirements for battery chargers
Zaandam, February 2014
M. van Veen
Powersine Combi
28
INHOUDSOPGAVE
1. INLEIDING ............................................................................................................................. 29
2. ALGEMEEN ............................................................................................................................ 30
3. HET CONFIGUREREN VAN DE POWERSINE COMBI .............................................................. 31
3.1 Algemeen ................................................................................................................... 31
3.2 Standaard fabrieksinstellingen .................................................................................. 31
3.3 Overzicht van de DIP switch instellingen................................................................... 34
4. ALGEMENE WERKING ........................................................................................................... 37
4.1 Bediening van de Powersine Combi .......................................................................... 37
4.2 Powersine Combi LED indicatoren en error modes .................................................. 37
4.2.1. Error indicatoren ................................................................................................... 39
4.3 Programmeerbaar Alarm relais ................................................................................. 39
4.4 Trigger ingang ............................................................................................................ 40
4.5 Belastingseisen in omvormer modus ........................................................................ 40
5. CHARGER OPERATION .......................................................................................................... 41
5.1 Laad programma’s ..................................................................................................... 41
5.2 Het “Equalizen” van een open lood-zuur accu .......................................................... 42
6. STORINGSTABEL ................................................................................................................... 44
7. TECHNISCHE SPECIFICATIES ................................................................................................. 48
8. GARANTIE / AANSPRAKELIJKHEID FABRIKANT ..................................................................... 51
9. CONFORMITEITSVERKLARING .............................................................................................. 51
Powersine Combi
29
1. INLEIDING
Bedankt voor de aanschaf van een SAMLEX Powersine Combi omvormer/lader combinatie!
Het is belangrijk deze gebruiksaanwijzing te lezen voor een correct en veilig gebruik van dit
product. Aanbevolen wordt om deze gebruiksaanwijzing plus alle andere bijgesloten
documentatie, in de buurt van dit product te houden voor het toekomstig naslaan van
informatie. Voor de meest recente gebruiksaanwijzing kunt u altijd de downloads pagina op
onze website bezoeken.
Het doel van deze gebruiksaanwijzing is om de bediening en configuratie van de Powersine
Combi uit te leggen. Voor de installatie is een separaat installatie voorschriften document
bijgesloten. Dit document is bedoelt voor installateurs welke kennis en ervaring hebben op
het gebied van het installeren van elektrische apparatuur. Tevens is kennis noodzakelijk
betreffende de lokaal geldende normen voor elektrische installaties en dient de installateur
zich ervan bewust te zijn te werken met gevaarlijke spanningen en zeer hoge stromen.
WAARSCHUWING
Powersine Combi
30
2. ALGEMEEN
De Powersine Combi is een alles-in-één combinatie van een pure sinus omvormer, een
geavanceerde meertraps acculader en een ultra snelle AC transfer switch. Dit alles
samengevoegd in een compacte en installatie vriendelijke behuizing. Naast deze drie basis
functionaliteiten, worden er ook nog een aantal ander unieke opties geboden. Een aantal
van deze opties maken optimaal gebruik van de sterke interactie tussen de drie basis
functionaliteiten.
De Powersine Combi gedraagt zich hoofdzakelijk als een ononderbroken AC voeding (UPS).
Wanneer het aangesloten lichtnet of generator buiten het bereik valt of losgekoppeld wordt,
zal de Powersine Combi onmiddellijk stoppen met laden, de AC transfer switch openen en de
omvormer activeren om de aangesloten belasting van energie te blijven voorzien. Dit alles
gebeurt dermate snel, dat zelfs zeer kritische belastingen zoals computers zonder problemen
door blijven werken. Wanneer het lichtnet of generator weer aangesloten wordt en de
spannings- en frequentie nivo’s binnen het bereik liggen, zal de Powersine Combi de AC
transfer switch weer sluiten en aanvangen met laden. De aangesloten belasting zal nu weer
gevoed worden vanuit het lichtnet of de generator.
Verder biedt de Powersine Combi de volgende mogelijkheden :
- AC Input Power Boost, waarbij tijdelijk een zwakke AC ingangsbron ondersteund kan
worden, wanneer de belasting meer vermogen vraagt dan de AC ingangsbron kan
leveren. Hierbij werkt de omvormer parallel aan de AC ingangsbron.
- AC Input Current Limit, waarbij automatisch de maximale ingangsstroom gelimiteerd
wordt, welke de Powersine Combi verbruikt. Deze limiet is door de gebruiker in te
stellen.
- Power Factor gecorrigeerde AC Ingang, optimaliseert het vermogensrendement en
zorgt voor een maximale laadstroom per Watt ingangsvermogen.
- Intelligente 4-staps laadprogramma’s, eventueel door de gebruiker zelf verder te
Optimaliseren, zodat elk batterij type veilig geladen kan worden.
- Volledig programmeerbare omvormer, AC transfer switch en lader parameters, door
gebruik te maken van de SAMLEX Dashboard voor Windows software.
- Programmeerbaar alarm relais, voor optimale controle over externe apparatuur, zoals
het starten van een generator of selectieve afschakeling van de belasting.
- Vrij toe te wijzen trigger ingang, voor geavanceerde gebruikers controle over de
Powersine Combi door middel van externe ‘events.
- Temperatuur afhankelijke ventilator snelheid, garandeert een zo stil mogelijke
werking van de Powersine Combi.
- Temperatuur gecompenseerd laden, door toepassing van de standaard meegeleverde
akku temperatuur sensor, voor een maximale akku levensduur.
Powersine Combi
31
3. HET CONFIGUREREN VAN DE POWERSINE COMBI
3.1 Algemeen
De Powersine Combi kan op twee manieren geconfigureerd worden. Met behulp van de DIP
switches in het aansluit compartiment, kunnen een klein aantal basis instellingen gemaakt
worden. In de meeste gevallen is dit voldoende om de Powersine Combi snel in te stellen
voor de gemiddelde applicatie. Een andere optie is om de Powersine Combi te configureren
met behulp van de SAMLEX Dashboard for Windows software. Deze software wordt
geleverd bij de optionele “SAMLEXLink to USB Communication Kit (art.# 64660)”, welke
tevens een geïsoleerde interface box bevat om de Powersine Combi aan te sluiten op een
PC. Met behulp van SAMLEX Dashboard kunnen alle beschikbare parameters aangepast
worden. Tevens is het mogelijk om zelf een laad programma te maken.
!
LET OP
Deze gebruiksaanwijzing beschrijft enkel de DIP switch instellingen en alle relevante
standaard fabrieksinstellingen. Configuratie m.b.v. SAMLEX Dashboard zal worden uitgelegd
in de SAMLEX Dashboard gebruiksaanwijzing, geleverd bij de “SAMLEXLink to USB
communication Kit.
3.2 Standaard fabrieksinstellingen
De onderstaande tabel geeft een overzicht van de meest relevante standaard
fabrieksinstellingen voor diverse parameters. De instellingen zijn gebaseerd op en
gemiddelde applicatie. SAMLEX kan niet garanderen dat deze correct zijn voor uw specifieke
applicatie. Controleer alle instellingen zorgvuldig, vooral de acculaadspanningen.
Parameter
Omvormer frequentie
Waarde
50Hz
Beschrijving
Uitgangsfrequentie in omvormer mode. Kan op 50Hz of 60Hz
ingesteld worden
Te configureren met
DIP switch (DIP 2) en Dashboard
Parameter
Omvormer spanning
Waarde
230V
Beschrijving
Uitgangsspanning in inverter mode. Kan van 200V t/m 240V
ingesteld worden.
Te configureren met
Dashboard
Parameter
Low Battery Protect
Powersine Combi
32
Waarde
Aan (On)
Beschrijving
Schakelt de beveiliging voor te lage accu spanning in of uit. Wanneer
ingeschakeld zijn door de gebruiker de uitschakel spanning, de her-
start spanning en de vertragingstijd in te stellen (standaard waardes
zijn respectievelijk 10V, 12V en 5 seconden). Wanneer uitgeschakeld
zal de omvormer direct stoppen bij een accu spanning van 8.0V of
lager.
Te configureren met
DIP switch (DIP 3) en Dashboard
Parameter
Automatic Stand By (ASB)
Waarde
Uit (Off)
Beschrijving
Schakelt ASB in of uit. Wanneer ingeschakeld zal de omvormer vanuit
de continu mode automatisch naar de ASB mode springen, als de
belasting onder een bepaald verbruiksnivo komt. In ASB mode
genereert de omvormer een pulserende sinus aan de uitgang, om te
detecteren wanneer de belasting meer vermogen vraagt. Zolang de
Powersine Combi in ASB mode staat, verbruikt deze aanzienlijk
minder stroom van de accu. Op het moment dat de belasting meer
vermogen vraagt, zal de omvormer automatisch weer terugspringen
naar de continu mode. Wanneer ASB uitgeschakeld wordt, zal de
omvormer altijd in continu mode opereren. Dit is beter voor kritische
belastingen zoals computers, klokken en A/V apparatuur.
Te configureren met
DIP switch (DIP 4) en Dashboard
Parameter
AC ingangsspanningsbereik (transfer switch)
Waarde
180V 270V
Beschrijving
Dit is het ingangsspanningsbereik welke wordt geaccepteerd door de
Powersine Combi om door te geven aan de aangesloten belasting. Er
kunnen twee AC onderspanningswaardes ingesteld worden. Een
absolute onderspanning waarbij direct de AC transfer switch opent
wanneer deze overschreden wordt (fabrieksinstelling = 150V), en een
vertraagde onderspanning welke de AC transfer switch opent na een
bepaalde tijd (fabrieksinstelling=180V en 5 seconden). Het laderdeel
stopt met werken wanneer de ingangsspanning onder de 185V zakt,
en herstart weer boven de 190V.
Te configureren met
Dashboard
Parameter
AC ingangsfrequentiebereik
Waarde
45Hz 65Hz
Beschrijving
Dit is het ingangsfrequentiebereik welke wordt geaccepteerd door de
Powersine Combi. Deze kan ingesteld worden op het volle bereik
(45Hz 65Hz), of op een kleiner bereik binnen de 45Hz en 65Hz
grenzen.
Te configureren met
Dashboard
Parameter
AC Input Current Limit
Waarde
16.0A of 30.0A (afhankelijk van model)
Beschrijving
Deze waarde representeert de maximale continue stroom welke de
Powersine Combi opneemt van de AC ingangsbron. Om dit te
realiseren zal de Powersine Combi of de laadstroom automatisch
Powersine Combi
33
reduceren, of (wanneer ingeschakeld) de AC Input Power Boost
functie activeren. De AC Input Power Boost functie zal de benodigde
extra stroom bijleveren, door de omvormer parallel aan de AC
ingangsbron te laten werken. Wanneer de belasting dan nog steeds
teveel stroom opneemt, kan de installateur kiezen om de AC transfer
switch te openen, of deze gesloten te houden en toestaan dat de AC
Input Current Limit waarde wordt overschreden. Deze waarde kan
worden ingesteld van 1.0A t/m 16.0A of 2.0A t/m 30A (afhankelijk van
model) in Dashboard of met de optionele Universal Remote Control.
Te configureren met
Dashboard and Universal Remote Control
Parameter
AC Input Power Boost
Waarde
Aan (On)
Beschrijving
AC Input Power Boost kan tijdelijk een zwakke AC ingangsbron
ondersteunen, wanneer de belasting meer vermogen vraagt dan de
AC ingangsbron kan leveren. Hierbij werkt de omvormer parallel aan
de AC ingangsbron. De omvormer kan maximaal het nominale
omvormer vermogen bij leveren, uitgaande van een gezonde accu.
Deze parameter kan aan (On) of uit (Off) gezet worden.
Te configureren met
DIP switch (DIP 7) en Dashboard
Parameter
Ground relais
Waarde
Geactiveerd (Enabled)
Beschrijving
Het ground relais verbindt automatisch de nul (N) met aarde (PE) aan
de uitgang, wanneer de Powersine Combi in omvormer mode werkt.
Op deze manier is het mogelijk een aardlek schakelaar in de AC
uitgang op te nemen. Wanneer een zwevende uitgang wenselijk is,
kan deze Parameter gedeactiveerd worden.
Te configureren met
DIP switch (DIP 8) (alleen bij modellen PSC2000-3500) en Dashboard
Parameter
AC input fail sensitivity
Waarde
Normaal (Normal)
Beschrijving
Deze parameter kan ingesteld worden op ‘Very Low’, ‘Low’, ‘Normal’,
‘High’ en ‘Very High. De waarde van deze parameter bepaald hoe
snel de Powersine Combi een signaal verlies detecteert op de AC
ingang. De lagere instellingen resulteren in een tragere omschakeling
van AC ingangsbron → omvormer, terwijl de hogere instellingen in de
snelste omschakel tijden resulteren. De instellingen ‘Low’ en ‘Very
Low’ kunnen gebruikt worden wanneer de ingangsspanning vervormt
of onstabiel is, bijvoorbeeld bij toepassing van een kleine generator.
De instellingen ‘High’ en ‘Very High’ kunnen gebruikt worden
wanneer de Powersine Combi is aangesloten op een solide lichtnet of
zwaardere (kwaliteits-) generator. De fabrieksinstelling ‘Normal’ is
een goed compromis tussen een snelle omschakeltijd (< 5ms) en een
redelijke immuniteit voor vervormde AC ingangssignalen.
Te configureren met
Dashboard
Parameter
Accu type / Laad programma
Waarde
AGM
Beschrijving
De fabrieksinstelling van deze Parameter is AGM, welke geschikt is
Powersine Combi
34
voor de meeste AGM type acc
u’s. Tevens is dit
programma geschikt
voor enkele andere lood zwavelzuur gebaseerde accu’s. Controleer
altijd of het gekozen laad programma geschikt is voor de toegepaste
accu! Het AGM laadprogramma heeft een ‘absorption’ spanning van
14.3V (28.6V@24V) en een ‘float’ spanning van 13.3V (26.6V@24V).
Andere selecteerbare laad programma’s zijn ‘Flooded (nat)’, ‘GEL’ en
Custom. Voor meer laad programma informatie, zie de
hoofdstukken 3.3 en 5.1.
Te configureren met
DIP switch (DIP 5 and 6) en Dashboard
Parameter
Laadstroom limiet
Waarde
100%
Beschrijving
Met behulp van deze Parameter kan de maximale laadstroom in
procent ingesteld worden. Deze waarde kan ingesteld van 10% t/m
100% in Dashboard of de optionele Universal Remote Control. Deze
waarde kan gereduceerd worden wanneer de aangesloten accu te
klein is en de maximum laadstroom daardoor te hoog. Deze waarde
kan ook gereduceerd worden wanneer het wenselijk is om (tijdelijk)
het stroom verbruik van de Powersine Combi in lader mode te
verlagen.
Te configureren met
Dashboard en Universal Remote Control
3.3 Overzicht van de DIP switch instellingen
In stap 3 van de installatie voorschriften is het mogelijk de fabrieksinstellingen van de DIP
switches te wijzigen. Dit kan wenselijk zijn om de functionaliteit van de Powersine Combi te
wijzigen. Voor meer specifieke informatie over de fabrieksinstellingen, zie het vorige
hoofdstuk (3.2). De volgende instellingen kunnen worden gemaakt :
Uitleg instellingen
Fabrieksinstelling = OFF
Lokale / Externe Programmering
ON (Extern) : DIP switches 2 t/m 7 of 9 worden
genegeerd en de Powersine Combi zal altijd
de Parameter instellingen gebruiken zoals
geconfigureerd in TBS Dashboard.
OFF (Lokaal) : De lokale DIP switch instellingen worden
gebruikt. Alle andere Parameter
instellingen staan op de fabriekswaarden.
Fabrieksinstelling = OFF
Omvormer uitgangsfrequentie
ON : Uitgangsfrequentie is 60Hz
OFF : Uitgangsfrequentie is 50Hz
Powersine Combi
35
Fabrieksinstelling = ON
Low battery protect
ON : Low battery protect is geactiveerd
OFF : Low battery protect is gedeactiveerd (onmiddelijke
omvormer uitschakeling bij een Uaccu < 8.0V)
Fabrieksinstelling = OFF
ASB mode
ON : ASB mode is geactiveerd
OFF : ASB mode is deactiveerd
Fabrieksinstelling 5 = OFF
Fabrieksinstelling 6 = ON
Akku type / Laadprogramma
1)
5 = OFF : Accu type = Flooded’ (nat)
6 = OFF Absorption spanning = 14.4V of 28.8V
Float spanning = 13.5V of 27.0V
5 = ON : Accu type = GEL
6 = OFF Absorption spanning = 14.2V of 28.4V
Float spanning = 13.5V of 27.0V
5 = OFF : Accu type = AGM
6 = ON Absorption spanning = 14.3V of 28.6V
Float spanning = 13.3V of 26.6V
5 = ON : Accu type = Custom
6 = ON Absorption spanning = ingesteld in Dashboard
‘Float’ spanning = ingesteld in Dashboard
Fabrieksinstelling = OFF
AC Input Power Boost
ON : AC Input Power Boost is geactiveerd
OFF : AC Input Power Boost is gedeactiveerd
Fabrieksinstelling = ON
Modellen : PSC1600-1800
Overbrug ‘remote switch’ (Overbrugt de ‘remote switch’
aansluiting wanneer er geen ‘remote switch’ is aangesloten.
ON : remote switch’ aansluitingen zijn overbrugd
OFF : ‘remote switch’ aansluitingen zijn niet overbrugd.
Sluit een schakelaar aan op de daarvoor bestemde
connectoren. Deze moet ingeschakeld worden om
de Powersine Combi aan te zetten. De hoofd
schakelaar op het frontpaneel heeft altijd de
hoogste prioriteit. Dus om de ‘remote switch’ te
kunnen gebruiken, moet de hoofd schakelaar altijd
op ‘on’ of ‘charger only’ staan.
Modellen : PSC2000-3500
Ground relais
Powersine Combi
36
ON : Ground relais is geactiveerd
OFF : Ground relais is gedeactiveerd
Fabrieksinstelling = OFF
Modellen : PSC2000-3500
Gereserveerd
Fabrieksinstelling = ON
Modellen : PSC2000-3500
Overbrug ‘remote switch’ (Overbrugt de ‘remote switch’
aansluiting wanneer er geen ‘remote switch’ is aangesloten.
ON : remote switch’ aansluitingen zijn overbrugd
OFF : ‘remote switch’ aansluitingen zijn niet overbrugd.
Sluit een schakelaar aan op de daarvoor bestemde
connectoren. Deze moet ingeschakeld worden om
de Powersine Combi aan te zetten. De hoofd
schakelaar op het frontpaneel heeft altijd de
hoogste prioriteit. Dus om de ‘remote switch’ te
kunnen gebruiken, moet de hoofd schakelaar altijd
op ‘on’ of ‘charger only’ staan.
!
LET OP
Powersine Combi
37
4. ALGEMENE WERKING
4.1 Bediening van de Powersine Combi
De hoofdschakelaar op het frontpaneel van de Powersine Combi heeft drie posities : On,
Off en Charger only (zie afbeelding in hoofdstuk 4.2).
Wanneer ingeschakeld op ‘On’, zal de Powersine Combi alle taken automatisch vervullen. Er
wordt opgestart in omvormer mode welke de aangesloten belasting zal voeden.
Tegelijkertijd zal de Powersine Combi continu de AC ingang in de gaten houden. Wanneer er
qua spanningsnivo en frequentie een bruikbaar signaal verschijnt op de AC ingang (b.v.
nadat er een generator is opgestart), zal Powersine Combi synchroniseren met dit
ingangssignaal en vervolgens de AC transfer switch sluiten. Nu wordt de aangesloten
belasting gevoed door de AC ingangsbron en kan de Powersine Combi tevens aanvangen
met het laden van de akku. Wanneer de spanning of frequentie van het ingangssignaal de
ingestelde grenzen overschrijdt (b.v. omdat de AC ingangsbron wordt afgekoppeld), zal de
Powersine Combi onmiddellijk stoppen met laden, de AC transfer switch openen en de
omvormer activeren. Dit alles gebeurt dermate snel, dat de aangesloten belasting hiervan
niets zal merken.
Wanneer de hoofdschakelaar op ‘Off’ staat, is de Powersine Combi volledig uitgeschakeld en
kan ook niet worden ingeschakeld door een remote switch of de Universal Remote Control.
In deze ‘Off’ mode zal de Powersine Combi geen stroom verbruiken van de akku.
Wanneer ingeschakeld op ‘Charger only’, zal de Powersine Combi het omvormer deel
uitschakelen en alleen als lader functioneren. Als er een bruikbaar AC ingangssignaal
aanwezig is, sluit de AC transfer switch en vangt het laad proces aan. Wanneer het AC
ingangssignaal faalt, opent de AC transfer switch weer en het laad proces wordt gestaakt. In
deze conditie is er ook geen AC signaal aanwezig op de uitgang van de Powersine Combi.
Informatie betreffende de LED indicatoren en de diverse error modes, staat vermeld in het
volgende hoofdstuk.
4.2 Powersine Combi LED indicatoren en error modes
In de volgende afbeelding ziet u een overzicht van alle indicatoren op het Powersine Combi
frontpaneel, plus de locatie van de hoofdschakelaar.
Powersine Combi
38
Het frontpaneel kan worden opgedeeld in de volgende secties :
1. Multifunctionele nivo indicator. Geeft een procentuele indicatie weer van het
geleverde uitgangsvermogen in omvormer mode (kleurt rood wanneer meer dan het
nominale vermogen wordt geleverd aan de belasting). In lader mode geeft deze
indicator het laadstroom percentage aan.
2. Mode indicatoren. Geven aan in welke modus de Powersine Combi zich bevindt, en
wat de status van de diverse modi is (zie uitleg hieronder) :
‘charger on’ LED
Uit : Lader niet actief
Aan (groen) : Lader actief
Aan (knipperend rood) : Error (zie hoofdstuk 4.2.1)
Aan (rood) : Lader gedeactiveerd
‘inverter on’ LED
Uit : Omvormer niet actief
Aan (groen) : Omvormer actief of Power Boost actief
Aan (knipperend rood) : Error (zie hoofdstuk 4.2.1)
Aan (rood) : Omvormer gedeactiveerd
‘AC in’ LED
Uit : Geen AC ingangssignaal, AC transfer switch
is open
Aan (knipperend groen) : AC ingangssignaal aanwezig en binnen
bereik, Powersine Combi is bezig met
synchroniseren
Aan (groen) : AC ingangssignaal is goedgekeurd, AC
transfer switch is gesloten
Powersine Combi
39
Aan (knipperend rood) : AC ingangssignaal aanwezig maar buiten
het bereik
Aan (rood) : AC transfer switch gedeactiveerd
3. Laad status indicator. Geeft een ruwe indicatie van de laadvoortgang, zie hieronder :
LED 3a : 100% vol (laden gereed)
LED 3b : 80% vol
LED 3c : 50% vol
LED 3d : leeg
4. Hoofdschakelaar. Zie hoofdstuk 4.1 voor uitleg.
4.2.1. Error indicatoren
Wanneer de mode indicatoren rood knipperen, is er een error gedetecteerd. Elke mode
indicator LED kan individueel knipperen, of gecombineerd met één of twee andere mode
indicator LED’s. Er zijn vijf verschillende error modes, welke elk een eigen flits patroon
hebben :
Eén flits per keer : Accu gerelateerde error (Te lage of hoge accuspanning, te lage
of hoge accu temperatuur, te hoge rimpelspanning, accu
defect)
Twee flitsen per keer : AC overbelasting error (AC belasting te hoog voor de
omvormer, kortsluiting op de AC uitgang)
Drie flitsen per keer : Hoge temperatuur error (De Powersine Combi schakelt zichzelf
uit vanwege een te hoge temperatuur)
Vier flitsen per keer : Apparaat error (Er is een fout geconstateerd in de Powersine
Combi. Deze dient geretourneerd te worden voor service)
Vijf flitsen per keer : Laadprogramma error (alleen geldig voor ‘charger on’ LED).
Laadprogramma selectie staat op Custom, terwijl het Custom
laadprogramma een fout bevat.
De Powersine Combi herstelt in de meeste gevallen automatisch van een error mode,
wanneer de oorzaak van de error opgelost is. Echter wanneer er een error optreedt vanwege
een te hoge DC rimpelspanning of een te hoge AC transfer switch stroom, is een manuele
herstart van de Powersine Combi noodzakelijk (uit- en inschakelen van de hoofdschakelaar).
De Powersine Combi moet ook manueel herstart worden wanneer er meerdere accu- of
overbelasting errors kort achter elkaar gedetecteerd worden.
4.3 Programmeerbaar Alarm relais
De Powersine Combi is uitgerust met één of twee (afhankelijk van model) potentiaalvrije
alarm relais. Standaard zal dit relais (of relais 1 bij de PSC2000-3500 modellen) sluiten
wanneer de Powersine Combi uitschakelt en naar een error mode springt. Het alarm relais
zal weer openen wanneer de error conditie opgelost is en de unit weer normaal opereert.
Powersine Combi
40
Relais 2 bij de PSC2000-3500 modellen wordt alleen geactiveerd wanneer er een AC
ingangsbron aanwezig is. Dit relais wordt direct gedeactiveerd wanneer er vanuit de accu
gewerkt wordt. Deze functionaliteit kan worden gebruikt om minder kritische belastingen
(zoals een boiler of airco) aan- en uit te schakelen, wanneer deze alleen vanuit het net of
generator mogen werken.
Met behulp van SAMLEX Dashboard, is het ook mogelijk om de programmeerbare relais zo
te configureren dat deze andere taken kunnen vervullen, zoals bijvoorbeeld het starten van
een generator wanneer de akkuspanning een bepaalde waarde heeft bereikt.
Zowel de normaal gesloten als de normaal geopende relais contacten zijn beschikbaar. Bij de
PSC1600-1800 modellen zijn deze relais contacten maximaal belastbaar met 30Vdc/1A of
60Vdc/0.3A. Bij de PSC2000-3500 modellen zijn deze relais contacten maximaal belastbaar
met 30Vdc/16A of 250Vac/16A.
4.4 Trigger ingang
De trigger ingang biedt de mogelijkheid om het gedrag van de Powersine Combi extern te
besturen. Op deze ingang kan een externe schakelaar of potentiaal vrij relais contact
aangesloten worden. Wanneer deze externe schakelaar of relais contact gesloten wordt, kan
een door de gebruiker ingestelde ‘action’ geactiveerd worden. Een ‘action’ kan bijvoorbeeld
het openen van de AC transfer switch zijn, het uitschakelen van de AC Input Power Boost
mogelijkheid of het naar omvormer modus forceren van de Powersine Combi. Dit alles kan
geconfigureerd worden in SAMLEX Dashboard. De PSC1600-1800 modellen zijn uitgerust
met één trigger ingang, terwijl de PSC2000-3500 modellen twee van deze ingangen hebben.
4.5 Belastingseisen in omvormer modus
Voordat u de belasting aansluit op de uitgang van de Powersine Combi, dient u te allen
tijden het maximale verbruik van deze belasting te controleren. Sluit geen belasting aan
welke meer verbruikt dan het nominale vermogen van de omvormer. Tenzij deze belasting
alleen wordt ingeschakeld wanneer de AC transfer switch gesloten is en het vermogen
geleverd wordt door een AC bron met een hogere capaciteit dan de omvormer.
Sommige belastingen welke een motor of pomp bevatten, kunnen hoge inschakelstromen
trekken bij het opstarten. Het is mogelijk dat deze inschakelstroom de overstroom
beveiliging van de omvormer aanspreekt. In dit geval zal de uitgangsspanning kort afnemen
om de uitgangsstroom van omvormer te limiteren. Wanneer de overstroom beveiliging
continu wordt aangesproken, zal de Powersine Combi naar een error mode stappen en
automatisch na ca. 20 seconden herstarten. In dit geval is het raadzaam de belasting af te
koppelen, aangezien deze teveel verbruikt voor dit model Powersine Combi. De Powersine
Combi moet manueel herstart worden (middels de hoofdschakelaar), wanneer deze vier
keer achter elkaar in een error mode heeft gestaan. Houd rekening met het feit dat bij
hogere omgevingstemperaturen, de overbelastbaarheid van de Powersine Combi afneemt.
Powersine Combi
41
5. CHARGER OPERATION
5.1 Laad programma’s
Alle standaard te selecteren laadprogramma’s (middels DIP switches 5 en 6), verrichten
een viertraps IuoUoP laad proces bestaande uit een “Bulk” , een “Absorption”, een “Float”
en een “Pulse” fase. De volgende afbeelding toont het viertraps laad proces :
In de Bulk fase levert de lader de volledige laadstroom en zal de accu tot gemiddeld zo’n 80%
opladen wanneer de absorptie spanning is bereikt. Gedurende deze fase lichten
Indicatoren 3d (zie hoofdstuk 4.2) en 3c op, afhankelijk van de voortgang. Wanneer de
absorptie spanning is bereikt, zal de absorption fase aanvangen waarbij ook indicator 3b op
zal lichten. Deze fase zal de overige 20% van de accu capaciteit aanvullen. De
uitgangsspanning wordt hierbij constant gehouden en de laadstroom zal afnemen als gevolg
het steeds voller worden van de accu. Wanneer de laadstroom is afgenomen tot onder een
bepaalde waarde of wanneer de maximale absorption timer is verstreken, zal de float fase
aanvangen. Indicator 3a zal oplichten en er klinkt een akoestische melding om aan te geven
dat de accu vol is. In deze fase wordt de accu spanning constant gehouden op een waarde
welke veilig is voor de accu. Dit zorgt ervoor dat de accu in optimale conditie blijft zolang
deze staat aangesloten op de geactiveerde lader. Aangesloten accu belastingen worden
direct door de lader gevoed tot aan de maximale uitgangsstroom van de lader. Wanneer
meer dan deze maximale stroom wordt gevraagd door de belasting, zal de accu dit moeten
Powersine Combi
42
bijleveren wat resulteert in een dalende accuspanning. Vanaf een bepaalde accuspanning,
zal de lader terugspringen naar de bulk fase en wederom een compleet viertraps laad proces
uitvoeren wanneer de belastingsstroom weer gedaald is tot onder de maximale laadstroom
van de lader.
Een vierde fase genaamd pulse activeert, zolang de lader opereert in de float fase, elke 7
dagen een kort laadproces van ca. 1 uur. Dit houdt de accu in optimale conditie en verlengd
daarnaast de levensduur. De accu kan dus aangesloten blijven op de geactiveerde lader
zonder enig risico op overlading.
Wanneer de accu temperatuursensor geïnstalleerd is, zal de lader automatisch de laad
spanningen compenseren tegen temperatuur. Dit betekent dat de laad spanningen licht
stijgen bij lagere temperaturen en dalen bij hogere temperaturen (-30mV/°C bij 12V
modellen en -60mV/°C bij 24V modellen). Op deze manier wordt overlading voorkomen wat
de levensduur van de accu verlengd.
Wanneer de standaard te selecteren laadprogramma’s niet voldoen aan uw eisen, of
wanneer afwijkende laadspanningen of stromen nodig zijn, kunt u met de optionele
SAMLEXLink to USB communication kit uw eigen laadprogramma’s creëren in SAMLEX
Dashboard. Tot 8 verschillende laad fases kunnen met elkaar verbonden worden en elke
individuele laad fase kan zeer uitgebreid geconfigureerd worden. Vraagt u alstublieft uw
SAMLEX leverancier voor meer informatie over de SAMLEXLink to USB communication kit.
5.2 Het “Equalizen” van een open lood-zuur accu
Wanneer u een open lood-zuur accu gebruikt, zou het af en toe equalizen van deze accu
aangeraden kunnen worden door de accufabrikant. Dit zou ook kunnen gelden wanneer de
open lood-zuur accu te diep ontladen is geweest, of regelmatig onvolledig geladen wordt.
Gedurende een equalize laadstap, zal de accu geladen worden tot 15.5V (of 31V bij 24V
modellen) bij een gereduceerd uitgangsstroom nivo. Voordat een equalize laadstap gestart
wordt, dienen de onderstaande waarschuwingen eerst gelezen te worden :
!
LET OP
Powersine Combi
43
moet worden. De gebruiker dient het soortelijk gewicht van het zuur gedurende dit proces
in de gaten te houden, om het einde van de equalize laadstap te bepalen. De interne 2 uur
timer van de Powersine Combi is alleen bedoeld als veiligheidsoptie, maar zou te lang
kunnen duren om accu schade te voorkomen. Om deze reden moet het equalizen altijd
Aangezien het equalizen alleen is toegestaan op open lood-zuur accu’s, staat de Powersine
Combi deze laadstap alleen toe wanneer het ‘open lood-zuur’ (Flooded) laadprogramma
geselecteerd is (zie hoofdstuk 3.3). Hiernaast dient de lader ook eerst een volledig
laadproces te hebben afgerond en te opereren in de float fase. Wanneer aan deze twee
condities is voldaan, kan de equalize laadstap worden geactiveerd door de verdiepte
equalize drukknop aan de onderkant van de lader (zie onderstaande afbeeldingen) voor drie
seconden ingedrukt te houden, totdat de laad status indicator gaat knipperen.
Modellen : PSC1600-1800 :
Modellen : PSC2000-3500 :
De lader staat een maximale equalize tijd toe van twee uur, voordat deze automatisch weer
terug stapt naar de float fase. Als het soortelijk zuur gewicht nog niet het door de accu
fabrikant aangegeven nivo heeft bereikt, kan er een nieuwe twee uur durende equalize
laadstap worden gestart door de drukknop wederom voor 3 seconden in te drukken. Hierbij
dient continu het soortelijk zuur gewicht in de gaten te worden gehouden. Wanneer dit
gewicht correct is, kan de equalize laadstap manueel worden beëindigd door de drukknop
kort in te drukken. De lader zal dan weer terug stappen naar de float fase.
Powersine Combi
44
6. STORINGSTABEL
Zie de tabel hieronder wanneer u problemen ondervindt met de Powersine Combi en/of de
installatie.
Probleem
Mogelijke oorzaak
Oplossing
Powersine Combi werkt niet.
Hoofdschakelaar staat in Off
(0) positie.
Zet de hoofdschakelaar in de
‘I’ of ‘II’ positie.
Remote switch of Universal
Remote Control hebben de
Powersine Combi
uitgeschakeld.
Activeer de Powersine Combi
op afstand of controleer DIP
switch 8 of 10 voor de
correcte instelling.
Slecht contact tussen de
Powersine Combi DC kabels
en de accupolen.
Zorg voor schone accupolen
en kabel ogen. Draai alle DC
verbindingsschroeven goed
aan.
Defecte DC zekering.
Controleer de accu zekering
of de interne DC zekering van
de Powersine Combi (alleen
PSC1600-1800).
Slechte accu conditie.
Vervang de accu.
De lader modus werkt niet
(ook de AC transfer switch
sluit niet).
De AC ingangsspanning of
frequentie liggen buiten het
bereik of zijn te onstabiel.
Zorg ervoor dat de AC
ingangsspanning tussen de
185V 270V ligt en de
frequentie tussen de 45Hz
65Hz (uitgaande van de
fabrieksinstellingen).
Lader deel en/of de AC
transfer switch zijn
gedeactiveerd tijdens het
configureren met Dashboard.
Activeer het lader deel en de
AC transfer switch weer met
behulp van Dashboard.
De accu wordt niet geheel
volgeladen
Incorrecte instelling van de
absorptie spanning.
Controleer DIP switch 5 en 6
voor correcte instellingen. Of
wijzig de absorptie spanning
met behulp van Dashboard.
Incorrecte laadstroom
instelling.
Stel de laadstroom correct af
met behulp van de Universal
Remote Control of SAMLEX
Dashboard. Gemiddeld
genomen dient de laad-
stroom ingesteld te worden
op 10%-20% van de totale
accu capaciteit.
Te veel spanningsverliezen in
de accu kabels en/of accu
Zorg ervoor dat de accu
kabels voldoende capaciteit
Powersine Combi
45
aansluitingen.
(kwadratuur) hebben.
Controleer of alle accu
aansluitingen solide en
corrosie vrij zijn.
Belasting op de accu
verbruikt teveel stroom
gedurende het laden.
Schakel de belasting uit, of
ontkoppel deze van de accu.
Laadstroom is te laag.
Hoge omgevingstemperatuur
Probeer de temperatuur
rond de Powersine Combi te
verlagen.
Lader opereert in de
absorptie laadfase.
Doe niets. De accu is bijna
volledig opgeladen en
verbruikt daardoor minder
stroom van de lader.
Mode indicator LED’s
‘inverter on’, ‘charger on’ en
‘AC in’ geven één flits per
keer in rood (accu error).
Accu spanning is te laag (<
8V@12V of <16V@24V).
Accu is defect, vervang deze.
Of de accu is zeer diep
ontladen. Laat deze dan
langzaam herstellen tot
boven de 8.5V (17V@24V)
zodat de AC transfer switch
en lader weer op kunnen
starten.
Accu spanning is te hoog (>
16.5V@12V of >33V@24V).
Controleer of een externe
bron op het DC systeem de
accu spanning teveel laat
stijgen.
Te hoge rimpelspanning op
de DC ingang (manuele
herstart noodzakelijk).
Controleer de accu
aansluitingen. Reduceer de
accukabellengte. Vergroot de
accucapaciteit of kabel
diameter. Zorg ervoor dat er
geen andere bronnen een
hoge rimpelspanning
produceren op het DC
systeem.
Alleen mode indicator LED
‘inverter on’ geeft één flits
per keer in rood.
Accu spanning is te laag
(<10V@12V of <20V@24V).
Bied een AC signaal aan op
de AC ingang en start een
laadproces. Wanneer een
andere uitschakelspanning
gewenst is in ‘Battery protect
On’ mode, kan Dashboard
gebruikt worden.
Alleen mode indicator LED
‘inverter on’ geeft twee
flitsen per keer in rood.
De omvormer wordt
overbelast.
Zorg ervoor dat het totale
vermogen van de belasting
lager is dan het nominale
uitgangsvermogen van de
Powersine Combi
46
Powersine Combi.
De belasting aan de AC
uitgang veroorzaakt een
kortsluiting.
Zorg ervoor dat de belasting
niet defect is. Controleer of
de AC bedrading en
aansluitingen geen
kortsluiting vormen.
De belasting(en) aan de AC
uitgang veroorzaakt een te
grote opstart stroom.
Probeer de belastingen één
voor één in te schakelen
i.p.v. tegelijk. In alle andere
gevallen is deze belasting te
zwaar voor de Powersine
Combi en is een groter
Powersine Combi model
noodzakelijk.
Mode indicator LED’s
‘inverter on’ en ‘charger on’
geven drie flitsen per keer in
rood.
De Powersine Combi is
uitgeschakeld vanwege een
te hoge temperatuur.
Reduceer de AC belasting in
omvormer mode. Probeer de
omgevingstemperatuur
rondom de Powersine Combi
te reduceren. Zorg voor een
vrije ruimte van minstens
10cm rondom de unit.
Blokkeer in geen geval de
luchtstroom rondom de
Powersine Combi en plaats
geen items op of over de
unit. Plaats de unit niet in
direct zonlicht of in de buurt
van warmte producerende
apparatuur.
Mode indicator LED ‘AC in’
geeft één flits per keer in
rood.
AC ingangssignaal is present,
maar valt buiten de vereiste
spanning en frequentie
grenzen.
Zorg ervoor dat het AC
ingangssignaal binnen de
185V- 270V en 45Hz-65Hz
valt.
Alle mode indicator LED’s
‘inverter on’, ‘charger on’ en
‘AC in’ geven twee flitsen per
seconde in rood. (manuele
herstart noodzakelijk)
Maximale AC transfer switch
stroom is overschreden.
Reduceer de belasting aan de
AC uitgang.
Mode indicator LED ‘inverter
on’ of ‘charger on’ of ‘AC in’
branden continu in rood.
De omvormer mode, de
lader mode of de AC transfer
switch zijn uitgeschakeld met
behulp van SAMLEX
Dashboard.
Wanneer gewenst, kunnen
deze met behulp van
SAMLEX Dashboard weer
ingeschakeld worden.
Wanneer alleen ‘inverter on’
continu rood brandt.
De Powersine Combi hoofd-
schakelaar staat in ‘charger
Powersine Combi
47
only’ mode, wat betekent
dat de omvormer mode is
uitgeschakeld.
Nivo indicator brandt rood
(omvormer mode).
De omvormer is overbelast
en zal na een bepaalde tijd
automatisch uitschakelen
(deze tijd is afhankelijk van
de mate van overbelasting).
Reduceer de belasting aan de
AC uitgang.
Alle mode indicator LED’s
‘inverter on’, ‘charger on’ en
‘AC in’ geven vier flitsen per
keer in rood.
De Powersine Combi is
verkeerd aangesloten of
defect.
Een externe AC bron is
aangesloten op de AC
uitgang in plaats van de AC
ingang. Of retourneer de
Powersine Combi voor
service.
Mode indicator LED ‘charger
on’ geeft vijf flitsen per keer
in rood.
Laad programma fout.
De gebruiker heeft een lege
of foutief laad programma
geselecteerd (‘custom’ laad
programma is af fabriek
leeg). Een door de gebruiker
in SAMLEX Dashboard
gemaakt laad programma
bevat een fout.
Wanneer geen van de bovenstaande oplossingen werken, kunt het beste contact opnemen
met een lokale SAMLEX distributeur voor verdere assistentie en/of reparatie van uw
Powersine Combi. Haal de Powersine Combi nooit zelf uit elkaar, aangezien er gevaarlijke
spanningen aanwezig kunnen zijn aan de binnenzijde. Tevens zal dit direct uw recht op
garantie ongeldig verklaren.
Powersine Combi
48
7. TECHNISCHE SPECIFICATIES
Parameter
PSC1600-12-60
PSC1800-24-35
Omvormer deel
Uitgangsvermogen
1)
Pnom
1300W
1400W
P10minuten
1600W
1800W
Ppiek
2500W
3000W
Uitgangsspanning / frequentie
230Vac ± 2% / 50Hz ± 0.05%
Uitgangsspanningsvorm
Pure sinusvorm (THD < 5%
1)
@ Pnom)
DC ingangsspanning (± 3% tol.) Nominaal
12V
24V
Bereik
10.5
2)
16Vdc
21
2)
32Vdc
Maximale rendement
92%
94%
Ruststroom verbruik
3)
[ASB]
< 10W [2.0W]
< 12W [2.0W]
Lader deel
AC ingangsspanning
185 270Vac / 45 65Hz / PF > 0.95
Maximale continue laadstroom
4)
60A
35A
Standaard laadspanning (bulk / float @ 25°C)
14.3V / 13.3V
28.6V / 26.6V
Laad algoritme / programma
IUoUoP, intelligent 4 stage, temp. comp.
AC Transfer switch
Maximale continue stroom
16Arms
Omschakeltijd (gemiddeld)
0ms (inv. → ACin) / < 5ms (ACin inv.)
Algemeen
Geschikt voor SAMLEXLink
Ja
Beveiligingen
hoge/lage accuspanning, hoge
temperatuur, overbelasting, kortsluiting,
hoge rimpelspanning en lage AC
ingangsspanning
DC (accu) aansluitingen
Twee kabels, lengte 1.5 meters, 35mm
2
AC aansluitingen
Schroef klemmen
Afmetingen behuizing
351 x 210 x 114mm
Gewicht
10.7kg
Beschermingsklasse / Aanbev. Omgevings-
temperatuur / Opslag temperatuur
IP21 / -20°C .. +50°C / -40°C .. +80°C
Normen
CE gemarkeerd volgens EMC richtlijn
2004/108/EC en Laagspanningsrichtlijn
2006/95/EC (EN60335-1 en EN60335-2-29).
RoHS richtlijn 2002/95/EC
N.B. : bovenstaande gegevens kunnen zonder aankondiging van de fabrikant veranderen
1) Gemeten met Ohmse belasting. Vermogensopgaves hebben een tolerantie van ± 10% en nemen af bij toenemende temperatuur (ca.
1.2%/°C vanaf 25°C).
2) Het onder voltage is dynamisch. Deze limiet daalt bij toenemende belasting om spanningsverliezen over kabels en/of aansluitingen te
compenseren.
3) Gemeten bij nominale ingangsspanning en 25°C omgevingstemperatuur.
4) Bij hoge omgevingstemperaturen zal de maximum laadstroom automatisch gereduceerd worden.
Powersine Combi
49
Parameter
PSC2000-12-80
PSC2500-24-50
Omvormer deel
Uitgangsvermogen
1)
Pnom
1800W
2000W
P10minuten
2100W
2500W
Ppiek
4000W
5500W
Uitgangsspanning / frequentie
230Vac ± 2% / 50Hz ± 0.05%
Uitgangsspanningsvorm
Pure sinusvorm (THD < 5%
1)
@ Pnom)
DC ingangsspanning (± 3% tol.) Nominaal
12V
24V
Bereik
10.5
2)
16Vdc
21
2)
32Vdc
Maximale rendement
92%
93%
Ruststroom verbruik
3)
[ASB]
< 20W [3.5W]
< 20W [4.0W]
Lader deel
AC ingangsspanning
185 270Vac / 45 65Hz / PF > 0.95
Maximale continue laadstroom
4)
(Sec. uitgang)
80A (4A)
50A (4A)
Standaard laadspanning (bulk / float @ 25°C)
14.3V / 13.3V
28.6V / 26.6V
Laad algoritme / programma
IUoUoP, intelligent 4 stage, temp. comp.
AC Transfer switch
Maximale continue stroom
30Arms
Omschakeltijd (gemiddeld)
0ms (inv. → ACin) / < 5ms (ACin inv.)
Algemeen
Geschikt voor SAMLEXLink
Ja
Beveiligingen
hoge/lage accuspanning, hoge
temperatuur, overbelasting, kortsluiting,
hoge rimpelspanning en lage AC
ingangsspanning
DC (accu) aansluitingen
M10 bout verbindingen
AC aansluitingen
Schroef klemmen
Afmetingen behuizing
370 x 431 x 132mm
Gewicht
18.5kg
Beschermingsklasse / Aanbev. Omgevings-
temperatuur / Opslag temperatuur
IP21 / -20°C .. +50°C / -40°C .. +80°C
Normen
CE gemarkeerd volgens EMC richtlijn
2004/108/EC en Laagspanningsrichtlijn
2006/95/EC (EN60335-1 en EN60335-2-29).
RoHS richtlijn 2002/95/EC
N.B. : bovenstaande gegevens kunnen zonder aankondiging van de fabrikant veranderen
1) Gemeten met Ohmse belasting. Vermogensopgaves hebben een tolerantie van ± 10% en nemen af bij toenemende temperatuur (ca.
1.2%/°C vanaf 25°C).
2) Het onder voltage is dynamisch. Deze limiet daalt bij toenemende belasting om spanningsverliezen over kabels en/of aansluitingen te
compenseren.
3) Gemeten bij nominale ingangsspanning en 25°C omgevingstemperatuur.
4) Bij hoge omgevingstemperaturen zal de maximum laadstroom automatisch gereduceerd worden.
Powersine Combi
50
Parameter
PSC3000-12-120
PSC3500-24-70
Omvormer deel
Uitgangsvermogen
1)
Pnom
2600W
2800W
P10minuten
3200W
3800W
Ppiek
5000W
6500W
Uitgangsspanning / frequentie
230Vac ± 2% / 50Hz ± 0.05%
Uitgangsspanningsvorm
Pure sinusvorm (THD < 5%
1)
@ Pnom)
DC ingangsspanning (± 3% tol.) Nominaal
12V
24V
Bereik
10.5
2)
16Vdc
21
2)
32Vdc
Maximale rendement
92%
93%
Ruststroom verbruik
3)
[ASB]
< 20W [3.5W]
< 20W [4.0W]
Lader deel
AC ingangsspanning
185 270Vac / 45 65Hz / PF > 0.95
Maximale continue laadstroom
4)
(Sec. uitgang)
120A (4A)
70A (4A)
Standaard laadspanning (bulk / float @ 25°C)
14.3V / 13.3V
28.6V / 26.6V
Laad algoritme / programma
IUoUoP, intelligent 4 stage, temp. comp.
AC Transfer switch
Maximale continue stroom
30Arms
Omschakeltijd (gemiddeld)
0ms (inv. → ACin) / < 5ms (ACin inv.)
Algemeen
Geschikt voor SAMLEXLink
Ja
Beveiligingen
hoge/lage accuspanning, hoge
temperatuur, overbelasting, kortsluiting,
hoge rimpelspanning en lage AC
ingangsspanning
DC (accu) aansluitingen
M10 bout verbindingen
AC aansluitingen
Schroef klemmen
Afmetingen behuizing
370 x 431 x 132mm
Gewicht
19.0kg
Beschermingsklasse / Aanbev. Omgevings-
temperatuur / Opslag temperatuur
IP21 / -20°C .. +50°C / -40°C .. +80°C
Normen
CE gemarkeerd volgens EMC richtlijn
2004/108/EC en Laagspanningsrichtlijn
2006/95/EC (EN60335-1 en EN60335-2-29).
RoHS richtlijn 2002/95/EC
N.B. : bovenstaande gegevens kunnen zonder aankondiging van de fabrikant veranderen
1) Gemeten met Ohmse belasting. Vermogensopgaves hebben een tolerantie van ± 10% en nemen af bij toenemende temperatuur (ca.
1.2%/°C vanaf 25°C).
2) Het onder voltage is dynamisch. Deze limiet daalt bij toenemende belasting om spanningsverliezen over kabels en/of aansluitingen te
compenseren.
3) Gemeten bij nominale ingangsspanning en 25°C omgevingstemperatuur.
4) Bij hoge omgevingstemperaturen zal de maximum laadstroom automatisch gereduceerd worden.
Powersine Combi
51
8. GARANTIE / AANSPRAKELIJKHEID FABRIKANT
Samlex Europe (SAMLEX) garandeert dit product vrij van defecten veroorzaakt in de
assemblage of door de gebruikte materialen, tot 24 maanden na de aankoop datum.
Gedurende deze periode neemt SAMLEX de kosten van eventuele reparatie voor zijn
rekening. SAMLEX is niet verantwoordelijk voor de transportkosten van dit product.
Deze garantie vervalt wanneer dit product fysiek beschadigd is zowel extern als intern,
als er iets aan het oorspronkelijk apparaat veranderd is of als de behuizing door een niet
gemachtigd persoon is geopend. Deze garantie dekt geen kosten veroorzaakt door onjuist
gebruik
1)
, pogingen om de omvormer zwaar over te belasten of door gebruik in niet
geschikte omgevingen.
Deze garantie is niet geldig wanneer dit product wordt misbruikt, verwaarloosd, onjuist
geïnstalleerd of gerepareerd door iemand anders dan door SAMLEX is aangewezen. De
fabrikant is niet verantwoordelijk voor enig verlies, schade of kosten voortvloeiende uit
onjuist gebruik of installatie van dit product, gebruik in niet geschikte omgevingen en
product storing.
Omdat de fabrikant geen controle kan uitvoeren op het gebruik en de installatie (volgens
de lokaal geldende voorschriften) van de SAMLEX producten, is de eindgebruiker ten alle
tijden aansprakelijk voor het gebruik van de SAMLEX producten. SAMLEX producten zijn niet
ontworpen voor toepassing als kritisch component in (medische-) apparatuur of
systemen die een potentieel gevaar kunnen vormen voor mens, natuur en milieu. De
eindgebruiker is ten alle tijden verantwoordelijk voor de toepassing van SAMLEX produkten
in deze applicaties. De fabrikant accepteert geen verantwoordelijkheid voor mogelijke
inbreuk op patenten of andere rechten van derden, verbonden aan het gebruik van SAMLEX
producten. De fabrikant behoudt het recht om product specificaties te wijzigen zonder
voorafgaande aankondiging.
1)
Enkele voorbeelden van onjuist gebruik zijn :
- Het aanbieden van een te hoge ingangsspanning (DC of AC)
- Het verkeerd om aansluiten van de akku kabels
- Het aansluiten van niet geschikte accu’s
- Mechanisch te zwaar belaste behuizing en/of interne onderdelen, vanwege misbruik
of incorrecte verpakking
- Kontakt met vloeistoffen of oxidatie door condensatie
9. CONFORMITEITSVERKLARING
Zie pagina 27
www.samlex.com
www.samlex-solar.com

Documenttranscriptie

SINEWAVE INVERTER-CHARGER Sinewave inverter-charger Model No. PSC1600-12-60 PSC2000-12-80 PSC3000-12-120 PSC1800-24-35 PSC2500-24-50 PSC3500-24-70 Manual, Gebruiksaanwijzing, Benutzerhandbuch, Manuel Utilisateur, Manual Para Utilizador Please read this manual before operating your inverter-charger Powersine Combi Notice of Copyright Powersine Combi PSC1600-3500 inverter/charger owner’s manual © 2012-2014 Samlex Europe BV. All rights reserved. No part of this document may be reproduced in any form or disclosed to third parties without the express written permission of Samlex Europe BV, Aris van Broekweg15, 1507 BA ZAANDAM, The Netherlands. Samlex Europe BV reserves the right to revise this document and to periodically make changes to the content hereof without obligation or organization of such revisions or changes, unless required to do so by prior arrangement. Exclusions for documentation and product usage UNLESS SPECIFICALLY AGREED TO IN WRITING, SAMLEX EUROPE BV (“SAMLEX”) : 1. MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION 2. ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSSES, DAMAGES, COSTS OR EXPENSES, WHETHER SPECIAL, DIRECT, INDIRECT, CONSEQUENTIAL OR INCIDENTAL, WHICH MIGHT ARISE OUT OF THE USE OF SUCH INFORMATION. THE USE OF ANY SUCH INFORMATION WILL BE ENTIRELY AT THE USER’S RISK 3. REMINDS YOU THAT IF THIS MANUAL IS IN ANY LANGUAGE OTHER THAN ENGLISH OR DUTCH, ALTHOUGH STEPS HAVE BEEN TAKEN TO MAINTAIN THE ACCURACY OF THE TRANSLATION, THE ACCURACY CANNOT BE GUARANTEED. 4. MAKES NO WARRANTY, EITHER EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, REGARDING THESE SAMLEX PRODUCTS AND MAKES SUCH SAMLEX PRODUCTS AVAILABLE SOLELY ON AN “AS IS” BASIS. 5. SHALL IN NO EVENT BE LIABLE TO ANYONE FOR SPECIAL, COLLATERAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH OR ARISING OUT OF PURCHASE OR USE OF THESE SAMLEX PRODUCTS. THE SOLE AND EXCLUSIVE LIABILITY TO SAMLEX,REGARDLESS OF THE FORM OF ACTION, SHALL NOT EXCEED THE PURCHASE PRICE OF THE SAMLEX PRODUCTS DESCRIBED HERE IN. Document name, date and part number “Samlex PSC1600-3500 Manual Rev1endfs”, January 2014, 201183 1 Powersine Combi 9. DECLARATION OF CONFORMITY IMPORTER ADDRESS : Samlex Europe B.V. : Aris van Broekweg 15 1507 BA ZAANDAM The Netherlands Declares that the following products : PRODUCT TYPE MODELS : Professional inverter / charger combination : PSC1600-12-60, PSC1800-24-35, PSC2000-12-80, PSC2500-24-50, PSC3000-12-120, PSC3500-24-70 Conforms to the requirements of the following Directives of the European Union : EMC Directive 2004/108/EC The above product is in conformity with the following harmonized standards : Low Voltage Directive 2006/95/EC EN61000-6-3 : 2001 EMC - Generic Emissions Standard EN61000-6-2 : 2005 EMC - Generic Immunity Standard EN60335-1 : 1999 Generic safety standard EN60335-2-29 : 2004 Safety requirements for battery chargers Zaandam, February 2014 M. van Veen 27 Powersine Combi INHOUDSOPGAVE 1. INLEIDING ............................................................................................................................. 29 2. ALGEMEEN............................................................................................................................ 30 3. HET CONFIGUREREN VAN DE POWERSINE COMBI .............................................................. 31 3.1 Algemeen ................................................................................................................... 31 3.2 Standaard fabrieksinstellingen .................................................................................. 31 3.3 Overzicht van de DIP switch instellingen................................................................... 34 4. ALGEMENE WERKING ........................................................................................................... 37 4.1 Bediening van de Powersine Combi .......................................................................... 37 4.2 Powersine Combi LED indicatoren en error modes .................................................. 37 4.2.1. Error indicatoren ................................................................................................... 39 4.3 Programmeerbaar Alarm relais ................................................................................. 39 4.4 Trigger ingang ............................................................................................................ 40 4.5 Belastingseisen in omvormer modus ........................................................................ 40 5. CHARGER OPERATION .......................................................................................................... 41 5.1 Laad programma’s ..................................................................................................... 41 5.2 Het “Equalizen” van een open lood-zuur accu .......................................................... 42 6. STORINGSTABEL ................................................................................................................... 44 7. TECHNISCHE SPECIFICATIES ................................................................................................. 48 8. GARANTIE / AANSPRAKELIJKHEID FABRIKANT ..................................................................... 51 9. CONFORMITEITSVERKLARING .............................................................................................. 51 28 Powersine Combi 1. INLEIDING Bedankt voor de aanschaf van een SAMLEX Powersine Combi omvormer/lader combinatie! Het is belangrijk deze gebruiksaanwijzing te lezen voor een correct en veilig gebruik van dit product. Aanbevolen wordt om deze gebruiksaanwijzing plus alle andere bijgesloten documentatie, in de buurt van dit product te houden voor het toekomstig naslaan van informatie. Voor de meest recente gebruiksaanwijzing kunt u altijd de downloads pagina op onze website bezoeken. Het doel van deze gebruiksaanwijzing is om de bediening en configuratie van de Powersine Combi uit te leggen. Voor de installatie is een separaat installatie voorschriften document bijgesloten. Dit document is bedoelt voor installateurs welke kennis en ervaring hebben op het gebied van het installeren van elektrische apparatuur. Tevens is kennis noodzakelijk betreffende de lokaal geldende normen voor elektrische installaties en dient de installateur zich ervan bewust te zijn te werken met gevaarlijke spanningen en zeer hoge stromen. WAARSCHUWING Zorg ervoor dat u voordat u verder gaat met deze gebruiksaanwijzing, ook de bijgesloten veiligheidsflyer en installatievoorschriften heeft gelezen! 29 Powersine Combi 2. ALGEMEEN De Powersine Combi is een alles-in-één combinatie van een pure sinus omvormer, een geavanceerde meertraps acculader en een ultra snelle AC transfer switch. Dit alles samengevoegd in een compacte en installatie vriendelijke behuizing. Naast deze drie basis functionaliteiten, worden er ook nog een aantal ander unieke opties geboden. Een aantal van deze opties maken optimaal gebruik van de sterke interactie tussen de drie basis functionaliteiten. De Powersine Combi gedraagt zich hoofdzakelijk als een ononderbroken AC voeding (UPS). Wanneer het aangesloten lichtnet of generator buiten het bereik valt of losgekoppeld wordt, zal de Powersine Combi onmiddellijk stoppen met laden, de AC transfer switch openen en de omvormer activeren om de aangesloten belasting van energie te blijven voorzien. Dit alles gebeurt dermate snel, dat zelfs zeer kritische belastingen zoals computers zonder problemen door blijven werken. Wanneer het lichtnet of generator weer aangesloten wordt en de spannings- en frequentie nivo’s binnen het bereik liggen, zal de Powersine Combi de AC transfer switch weer sluiten en aanvangen met laden. De aangesloten belasting zal nu weer gevoed worden vanuit het lichtnet of de generator. Verder biedt de Powersine Combi de volgende mogelijkheden : - AC Input Power Boost, waarbij tijdelijk een zwakke AC ingangsbron ondersteund kan worden, wanneer de belasting meer vermogen vraagt dan de AC ingangsbron kan leveren. Hierbij werkt de omvormer parallel aan de AC ingangsbron. - AC Input Current Limit, waarbij automatisch de maximale ingangsstroom gelimiteerd wordt, welke de Powersine Combi verbruikt. Deze limiet is door de gebruiker in te stellen. - Power Factor gecorrigeerde AC Ingang, optimaliseert het vermogensrendement en zorgt voor een maximale laadstroom per Watt ingangsvermogen. - Intelligente 4-staps laadprogramma’s, eventueel door de gebruiker zelf verder te Optimaliseren, zodat elk batterij type veilig geladen kan worden. - Volledig programmeerbare omvormer, AC transfer switch en lader parameters, door gebruik te maken van de SAMLEX Dashboard voor Windows software. - Programmeerbaar alarm relais, voor optimale controle over externe apparatuur, zoals het starten van een generator of selectieve afschakeling van de belasting. - Vrij toe te wijzen trigger ingang, voor geavanceerde gebruikers controle over de Powersine Combi door middel van externe ‘events’. - Temperatuur afhankelijke ventilator snelheid, garandeert een zo stil mogelijke werking van de Powersine Combi. - Temperatuur gecompenseerd laden, door toepassing van de standaard meegeleverde akku temperatuur sensor, voor een maximale akku levensduur. 30 Powersine Combi 3. HET CONFIGUREREN VAN DE POWERSINE COMBI 3.1 Algemeen De Powersine Combi kan op twee manieren geconfigureerd worden. Met behulp van de DIP switches in het aansluit compartiment, kunnen een klein aantal basis instellingen gemaakt worden. In de meeste gevallen is dit voldoende om de Powersine Combi snel in te stellen voor de gemiddelde applicatie. Een andere optie is om de Powersine Combi te configureren met behulp van de SAMLEX Dashboard for Windows software. Deze software wordt geleverd bij de optionele “SAMLEXLink to USB Communication Kit (art.# 64660)”, welke tevens een geïsoleerde interface box bevat om de Powersine Combi aan te sluiten op een PC. Met behulp van SAMLEX Dashboard kunnen alle beschikbare parameters aangepast worden. Tevens is het mogelijk om zelf een laad programma te maken. ! LET OP Wanneer de Powersine Combi geconfigureerd wordt m.b.v. SAMLEX Dashboard, moet DIP switch 1 op ON (External) gezet worden. Wanneer deze op ON staat, worden alle overige DIP switch instellingen (2 t/m 7 of 9) genegeerd. De Powersine Combi zal dan altijd de instellingen gebruiken zoals geconfigureerd in SAMLEX Dashboard. Wanneer DIP switch 1 op OFF (Local) gezet wordt, zullen DIP switches 2 t/m 7 of 9 de in SAMLEX Dashboard gemaakte instellingen overschrijven met de actuele DIP switch waardes. De parameter instellingen welke niet m.b.v. DIP switches gemaakt kunnen worden, zullen dan terugkeren naar de standaard fabriekswaardes. Deze gebruiksaanwijzing beschrijft enkel de DIP switch instellingen en alle relevante standaard fabrieksinstellingen. Configuratie m.b.v. SAMLEX Dashboard zal worden uitgelegd in de SAMLEX Dashboard gebruiksaanwijzing, geleverd bij de “SAMLEXLink to USB communication Kit”. 3.2 Standaard fabrieksinstellingen De onderstaande tabel geeft een overzicht van de meest relevante standaard fabrieksinstellingen voor diverse parameters. De instellingen zijn gebaseerd op en gemiddelde applicatie. SAMLEX kan niet garanderen dat deze correct zijn voor uw specifieke applicatie. Controleer alle instellingen zorgvuldig, vooral de acculaadspanningen. Parameter Waarde Beschrijving Te configureren met Parameter Waarde Beschrijving Omvormer frequentie 50Hz Uitgangsfrequentie in omvormer mode. Kan op 50Hz of 60Hz ingesteld worden DIP switch (DIP 2) en Dashboard Te configureren met Omvormer spanning 230V Uitgangsspanning in inverter mode. Kan van 200V t/m 240V ingesteld worden. Dashboard Parameter Low Battery Protect 31 Powersine Combi Waarde Beschrijving Te configureren met Parameter Waarde Beschrijving Te configureren met Parameter Waarde Beschrijving Te configureren met Parameter Waarde Beschrijving Te configureren met Parameter Waarde Beschrijving Aan (On) Schakelt de beveiliging voor te lage accu spanning in of uit. Wanneer ingeschakeld zijn door de gebruiker de uitschakel spanning, de herstart spanning en de vertragingstijd in te stellen (standaard waardes zijn respectievelijk 10V, 12V en 5 seconden). Wanneer uitgeschakeld zal de omvormer direct stoppen bij een accu spanning van 8.0V of lager. DIP switch (DIP 3) en Dashboard Automatic Stand By (ASB) Uit (Off) Schakelt ASB in of uit. Wanneer ingeschakeld zal de omvormer vanuit de continu mode automatisch naar de ASB mode springen, als de belasting onder een bepaald verbruiksnivo komt. In ASB mode genereert de omvormer een pulserende sinus aan de uitgang, om te detecteren wanneer de belasting meer vermogen vraagt. Zolang de Powersine Combi in ASB mode staat, verbruikt deze aanzienlijk minder stroom van de accu. Op het moment dat de belasting meer vermogen vraagt, zal de omvormer automatisch weer terugspringen naar de continu mode. Wanneer ASB uitgeschakeld wordt, zal de omvormer altijd in continu mode opereren. Dit is beter voor kritische belastingen zoals computers, klokken en A/V apparatuur. DIP switch (DIP 4) en Dashboard AC ingangsspanningsbereik (transfer switch) 180V – 270V Dit is het ingangsspanningsbereik welke wordt geaccepteerd door de Powersine Combi om door te geven aan de aangesloten belasting. Er kunnen twee AC onderspanningswaardes ingesteld worden. Een absolute onderspanning waarbij direct de AC transfer switch opent wanneer deze overschreden wordt (fabrieksinstelling = 150V), en een vertraagde onderspanning welke de AC transfer switch opent na een bepaalde tijd (fabrieksinstelling=180V en 5 seconden). Het laderdeel stopt met werken wanneer de ingangsspanning onder de 185V zakt, en herstart weer boven de 190V. Dashboard AC ingangsfrequentiebereik 45Hz – 65Hz Dit is het ingangsfrequentiebereik welke wordt geaccepteerd door de Powersine Combi. Deze kan ingesteld worden op het volle bereik (45Hz – 65Hz), of op een kleiner bereik binnen de 45Hz en 65Hz grenzen. Dashboard AC Input Current Limit 16.0A of 30.0A (afhankelijk van model) Deze waarde representeert de maximale continue stroom welke de Powersine Combi opneemt van de AC ingangsbron. Om dit te realiseren zal de Powersine Combi of de laadstroom automatisch 32 Powersine Combi Te configureren met Parameter Waarde Beschrijving Te configureren met Parameter Waarde Beschrijving Te configureren met Parameter Waarde Beschrijving reduceren, of (wanneer ingeschakeld) de AC Input Power Boost functie activeren. De AC Input Power Boost functie zal de benodigde extra stroom bijleveren, door de omvormer parallel aan de AC ingangsbron te laten werken. Wanneer de belasting dan nog steeds teveel stroom opneemt, kan de installateur kiezen om de AC transfer switch te openen, of deze gesloten te houden en toestaan dat de AC Input Current Limit waarde wordt overschreden. Deze waarde kan worden ingesteld van 1.0A t/m 16.0A of 2.0A t/m 30A (afhankelijk van model) in Dashboard of met de optionele Universal Remote Control. Dashboard and Universal Remote Control AC Input Power Boost Aan (On) AC Input Power Boost kan tijdelijk een zwakke AC ingangsbron ondersteunen, wanneer de belasting meer vermogen vraagt dan de AC ingangsbron kan leveren. Hierbij werkt de omvormer parallel aan de AC ingangsbron. De omvormer kan maximaal het nominale omvormer vermogen bij leveren, uitgaande van een gezonde accu. Deze parameter kan aan (On) of uit (Off) gezet worden. DIP switch (DIP 7) en Dashboard Ground relais Geactiveerd (Enabled) Het ground relais verbindt automatisch de nul (N) met aarde (PE) aan de uitgang, wanneer de Powersine Combi in omvormer mode werkt. Op deze manier is het mogelijk een aardlek schakelaar in de AC uitgang op te nemen. Wanneer een zwevende uitgang wenselijk is, kan deze Parameter gedeactiveerd worden. DIP switch (DIP 8) (alleen bij modellen PSC2000-3500) en Dashboard Te configureren met AC input fail sensitivity Normaal (Normal) Deze parameter kan ingesteld worden op ‘Very Low’, ‘Low’, ‘Normal’, ‘High’ en ‘Very High’. De waarde van deze parameter bepaald hoe snel de Powersine Combi een signaal verlies detecteert op de AC ingang. De lagere instellingen resulteren in een tragere omschakeling van AC ingangsbron → omvormer, terwijl de hogere instellingen in de snelste omschakel tijden resulteren. De instellingen ‘Low’ en ‘Very Low’ kunnen gebruikt worden wanneer de ingangsspanning vervormt of onstabiel is, bijvoorbeeld bij toepassing van een kleine generator. De instellingen ‘High’ en ‘Very High’ kunnen gebruikt worden wanneer de Powersine Combi is aangesloten op een solide lichtnet of zwaardere (kwaliteits-) generator. De fabrieksinstelling ‘Normal’ is een goed compromis tussen een snelle omschakeltijd (< 5ms) en een redelijke immuniteit voor vervormde AC ingangssignalen. Dashboard Parameter Waarde Beschrijving Accu type / Laad programma AGM De fabrieksinstelling van deze Parameter is AGM, welke geschikt is 33 Powersine Combi Te configureren met Parameter Waarde Beschrijving Te configureren met 3.3 voor de meeste AGM type accu’s. Tevens is dit programma geschikt voor enkele andere lood zwavelzuur gebaseerde accu’s. Controleer altijd of het gekozen laad programma geschikt is voor de toegepaste accu! Het AGM laadprogramma heeft een ‘absorption’ spanning van 14.3V (28.6V@24V) en een ‘float’ spanning van 13.3V (26.6V@24V). Andere selecteerbare laad programma’s zijn ‘Flooded (nat)’, ‘GEL’ en ‘Custom’. Voor meer laad programma informatie, zie de hoofdstukken 3.3 en 5.1. DIP switch (DIP 5 and 6) en Dashboard Laadstroom limiet 100% Met behulp van deze Parameter kan de maximale laadstroom in procent ingesteld worden. Deze waarde kan ingesteld van 10% t/m 100% in Dashboard of de optionele Universal Remote Control. Deze waarde kan gereduceerd worden wanneer de aangesloten accu te klein is en de maximum laadstroom daardoor te hoog. Deze waarde kan ook gereduceerd worden wanneer het wenselijk is om (tijdelijk) het stroom verbruik van de Powersine Combi in lader mode te verlagen. Dashboard en Universal Remote Control Overzicht van de DIP switch instellingen In stap 3 van de installatie voorschriften is het mogelijk de fabrieksinstellingen van de DIP switches te wijzigen. Dit kan wenselijk zijn om de functionaliteit van de Powersine Combi te wijzigen. Voor meer specifieke informatie over de fabrieksinstellingen, zie het vorige hoofdstuk (3.2). De volgende instellingen kunnen worden gemaakt : Uitleg instellingen Lokale / Externe Programmering ON (Extern) : DIP switches 2 t/m 7 of 9 worden genegeerd en de Powersine Combi zal altijd de Parameter instellingen gebruiken zoals geconfigureerd in TBS Dashboard. Fabrieksinstelling = OFF OFF (Lokaal) : De lokale DIP switch instellingen worden gebruikt. Alle andere Parameter instellingen staan op de fabriekswaarden. Omvormer uitgangsfrequentie ON : Uitgangsfrequentie is 60Hz Fabrieksinstelling = OFF OFF : Uitgangsfrequentie is 50Hz 34 Powersine Combi Low battery protect ON : Low battery protect is geactiveerd Fabrieksinstelling = ON OFF : Low battery protect is gedeactiveerd (onmiddelijke omvormer uitschakeling bij een Uaccu < 8.0V) ASB mode ON : ASB mode is geactiveerd Fabrieksinstelling = OFF OFF : ASB mode is deactiveerd Akku type / Laadprogramma1) 5 = OFF : Accu type = ‘Flooded’ (nat) 6 = OFF ‘Absorption’ spanning = 14.4V of 28.8V ‘Float’ spanning = 13.5V of 27.0V 5 = ON : Accu type = GEL 6 = OFF ‘Absorption’ spanning = 14.2V of 28.4V ‘Float’ spanning = 13.5V of 27.0V Fabrieksinstelling 5 = OFF Fabrieksinstelling 6 = ON 5 = OFF : Accu type = AGM 6 = ON ‘Absorption’ spanning = 14.3V of 28.6V ‘Float’ spanning = 13.3V of 26.6V 5 = ON : Accu type = Custom 6 = ON ‘Absorption’ spanning = ingesteld in Dashboard ‘Float’ spanning = ingesteld in Dashboard AC Input Power Boost ON : AC Input Power Boost is geactiveerd Fabrieksinstelling = OFF OFF : AC Input Power Boost is gedeactiveerd Modellen : PSC1600-1800 Overbrug ‘remote switch’ (Overbrugt de ‘remote switch’ aansluiting wanneer er geen ‘remote switch’ is aangesloten. ON : ‘remote switch’ aansluitingen zijn overbrugd Fabrieksinstelling = ON OFF : ‘remote switch’ aansluitingen zijn niet overbrugd. Sluit een schakelaar aan op de daarvoor bestemde connectoren. Deze moet ingeschakeld worden om de Powersine Combi aan te zetten. De hoofd schakelaar op het frontpaneel heeft altijd de hoogste prioriteit. Dus om de ‘remote switch’ te kunnen gebruiken, moet de hoofd schakelaar altijd op ‘on’ of ‘charger only’ staan. Modellen : PSC2000-3500 Ground relais 35 Powersine Combi ON : Ground relais is geactiveerd OFF : Ground relais is gedeactiveerd Modellen : PSC2000-3500 Gereserveerd Fabrieksinstelling = OFF Modellen : PSC2000-3500 Overbrug ‘remote switch’ (Overbrugt de ‘remote switch’ aansluiting wanneer er geen ‘remote switch’ is aangesloten. ON : ‘remote switch’ aansluitingen zijn overbrugd Fabrieksinstelling = ON OFF : ‘remote switch’ aansluitingen zijn niet overbrugd. Sluit een schakelaar aan op de daarvoor bestemde connectoren. Deze moet ingeschakeld worden om de Powersine Combi aan te zetten. De hoofd schakelaar op het frontpaneel heeft altijd de hoogste prioriteit. Dus om de ‘remote switch’ te kunnen gebruiken, moet de hoofd schakelaar altijd op ‘on’ of ‘charger only’ staan. ! LET OP 1) Een verkeerde accu type instelling, kan serieuze schade aanbrengen aan de accu of belastingen welke op de accu zijn aangesloten. Raadpleeg te allen tijde de specificaties van de accu voor de correcte laadspanningen en stromen. 36 Powersine Combi 4. ALGEMENE WERKING 4.1 Bediening van de Powersine Combi De hoofdschakelaar op het frontpaneel van de Powersine Combi heeft drie posities : ‘On’, ‘Off’ en ‘Charger only’ (zie afbeelding in hoofdstuk 4.2). Wanneer ingeschakeld op ‘On’, zal de Powersine Combi alle taken automatisch vervullen. Er wordt opgestart in omvormer mode welke de aangesloten belasting zal voeden. Tegelijkertijd zal de Powersine Combi continu de AC ingang in de gaten houden. Wanneer er qua spanningsnivo en frequentie een bruikbaar signaal verschijnt op de AC ingang (b.v. nadat er een generator is opgestart), zal Powersine Combi synchroniseren met dit ingangssignaal en vervolgens de AC transfer switch sluiten. Nu wordt de aangesloten belasting gevoed door de AC ingangsbron en kan de Powersine Combi tevens aanvangen met het laden van de akku. Wanneer de spanning of frequentie van het ingangssignaal de ingestelde grenzen overschrijdt (b.v. omdat de AC ingangsbron wordt afgekoppeld), zal de Powersine Combi onmiddellijk stoppen met laden, de AC transfer switch openen en de omvormer activeren. Dit alles gebeurt dermate snel, dat de aangesloten belasting hiervan niets zal merken. Wanneer de hoofdschakelaar op ‘Off’ staat, is de Powersine Combi volledig uitgeschakeld en kan ook niet worden ingeschakeld door een remote switch of de Universal Remote Control. In deze ‘Off’ mode zal de Powersine Combi geen stroom verbruiken van de akku. Wanneer ingeschakeld op ‘Charger only’, zal de Powersine Combi het omvormer deel uitschakelen en alleen als lader functioneren. Als er een bruikbaar AC ingangssignaal aanwezig is, sluit de AC transfer switch en vangt het laad proces aan. Wanneer het AC ingangssignaal faalt, opent de AC transfer switch weer en het laad proces wordt gestaakt. In deze conditie is er ook geen AC signaal aanwezig op de uitgang van de Powersine Combi. Informatie betreffende de LED indicatoren en de diverse error modes, staat vermeld in het volgende hoofdstuk. 4.2 Powersine Combi LED indicatoren en error modes In de volgende afbeelding ziet u een overzicht van alle indicatoren op het Powersine Combi frontpaneel, plus de locatie van de hoofdschakelaar. 37 Powersine Combi Het frontpaneel kan worden opgedeeld in de volgende secties : 1. Multifunctionele nivo indicator. Geeft een procentuele indicatie weer van het geleverde uitgangsvermogen in omvormer mode (kleurt rood wanneer meer dan het nominale vermogen wordt geleverd aan de belasting). In lader mode geeft deze indicator het laadstroom percentage aan. 2. Mode indicatoren. Geven aan in welke modus de Powersine Combi zich bevindt, en wat de status van de diverse modi is (zie uitleg hieronder) : ‘charger on’ LED Uit Aan (groen) Aan (knipperend rood) Aan (rood) : : : : Lader niet actief Lader actief Error (zie hoofdstuk 4.2.1) Lader gedeactiveerd ‘inverter on’ LED Uit Aan (groen) Aan (knipperend rood) Aan (rood) : : : : Omvormer niet actief Omvormer actief of Power Boost actief Error (zie hoofdstuk 4.2.1) Omvormer gedeactiveerd ‘AC in’ LED Uit : Geen AC ingangssignaal, AC transfer switch is open Aan (knipperend groen) : AC ingangssignaal aanwezig en binnen bereik, Powersine Combi is bezig met synchroniseren Aan (groen) : AC ingangssignaal is goedgekeurd, AC transfer switch is gesloten 38 Powersine Combi Aan (knipperend rood) : AC ingangssignaal aanwezig maar buiten het bereik : AC transfer switch gedeactiveerd Aan (rood) 3. Laad status indicator. Geeft een ruwe indicatie van de laadvoortgang, zie hieronder : LED 3a LED 3b LED 3c LED 3d : : : : 100% vol (laden gereed) 80% vol 50% vol leeg 4. Hoofdschakelaar. Zie hoofdstuk 4.1 voor uitleg. 4.2.1. Error indicatoren Wanneer de mode indicatoren rood knipperen, is er een error gedetecteerd. Elke mode indicator LED kan individueel knipperen, of gecombineerd met één of twee andere mode indicator LED’s. Er zijn vijf verschillende error modes, welke elk een eigen flits patroon hebben : Eén flits per keer : Accu gerelateerde error (Te lage of hoge accuspanning, te lage of hoge accu temperatuur, te hoge rimpelspanning, accu defect) Twee flitsen per keer : AC overbelasting error (AC belasting te hoog voor de omvormer, kortsluiting op de AC uitgang) Drie flitsen per keer : Hoge temperatuur error (De Powersine Combi schakelt zichzelf uit vanwege een te hoge temperatuur) Vier flitsen per keer : Apparaat error (Er is een fout geconstateerd in de Powersine Combi. Deze dient geretourneerd te worden voor service) Vijf flitsen per keer : Laadprogramma error (alleen geldig voor ‘charger on’ LED). Laadprogramma selectie staat op Custom, terwijl het Custom laadprogramma een fout bevat. De Powersine Combi herstelt in de meeste gevallen automatisch van een error mode, wanneer de oorzaak van de error opgelost is. Echter wanneer er een error optreedt vanwege een te hoge DC rimpelspanning of een te hoge AC transfer switch stroom, is een manuele herstart van de Powersine Combi noodzakelijk (uit- en inschakelen van de hoofdschakelaar). De Powersine Combi moet ook manueel herstart worden wanneer er meerdere accu- of overbelasting errors kort achter elkaar gedetecteerd worden. 4.3 Programmeerbaar Alarm relais De Powersine Combi is uitgerust met één of twee (afhankelijk van model) potentiaalvrije alarm relais. Standaard zal dit relais (of relais 1 bij de PSC2000-3500 modellen) sluiten wanneer de Powersine Combi uitschakelt en naar een error mode springt. Het alarm relais zal weer openen wanneer de error conditie opgelost is en de unit weer normaal opereert. 39 Powersine Combi Relais 2 bij de PSC2000-3500 modellen wordt alleen geactiveerd wanneer er een AC ingangsbron aanwezig is. Dit relais wordt direct gedeactiveerd wanneer er vanuit de accu gewerkt wordt. Deze functionaliteit kan worden gebruikt om minder kritische belastingen (zoals een boiler of airco) aan- en uit te schakelen, wanneer deze alleen vanuit het net of generator mogen werken. Met behulp van SAMLEX Dashboard, is het ook mogelijk om de programmeerbare relais zo te configureren dat deze andere taken kunnen vervullen, zoals bijvoorbeeld het starten van een generator wanneer de akkuspanning een bepaalde waarde heeft bereikt. Zowel de normaal gesloten als de normaal geopende relais contacten zijn beschikbaar. Bij de PSC1600-1800 modellen zijn deze relais contacten maximaal belastbaar met 30Vdc/1A of 60Vdc/0.3A. Bij de PSC2000-3500 modellen zijn deze relais contacten maximaal belastbaar met 30Vdc/16A of 250Vac/16A. 4.4 Trigger ingang De trigger ingang biedt de mogelijkheid om het gedrag van de Powersine Combi extern te besturen. Op deze ingang kan een externe schakelaar of potentiaal vrij relais contact aangesloten worden. Wanneer deze externe schakelaar of relais contact gesloten wordt, kan een door de gebruiker ingestelde ‘action’ geactiveerd worden. Een ‘action’ kan bijvoorbeeld het openen van de AC transfer switch zijn, het uitschakelen van de AC Input Power Boost mogelijkheid of het naar omvormer modus forceren van de Powersine Combi. Dit alles kan geconfigureerd worden in SAMLEX Dashboard. De PSC1600-1800 modellen zijn uitgerust met één trigger ingang, terwijl de PSC2000-3500 modellen twee van deze ingangen hebben. 4.5 Belastingseisen in omvormer modus Voordat u de belasting aansluit op de uitgang van de Powersine Combi, dient u te allen tijden het maximale verbruik van deze belasting te controleren. Sluit geen belasting aan welke meer verbruikt dan het nominale vermogen van de omvormer. Tenzij deze belasting alleen wordt ingeschakeld wanneer de AC transfer switch gesloten is en het vermogen geleverd wordt door een AC bron met een hogere capaciteit dan de omvormer. Sommige belastingen welke een motor of pomp bevatten, kunnen hoge inschakelstromen trekken bij het opstarten. Het is mogelijk dat deze inschakelstroom de overstroom beveiliging van de omvormer aanspreekt. In dit geval zal de uitgangsspanning kort afnemen om de uitgangsstroom van omvormer te limiteren. Wanneer de overstroom beveiliging continu wordt aangesproken, zal de Powersine Combi naar een error mode stappen en automatisch na ca. 20 seconden herstarten. In dit geval is het raadzaam de belasting af te koppelen, aangezien deze teveel verbruikt voor dit model Powersine Combi. De Powersine Combi moet manueel herstart worden (middels de hoofdschakelaar), wanneer deze vier keer achter elkaar in een error mode heeft gestaan. Houd rekening met het feit dat bij hogere omgevingstemperaturen, de overbelastbaarheid van de Powersine Combi afneemt. 40 Powersine Combi 5. CHARGER OPERATION 5.1 Laad programma’s Alle standaard te selecteren laadprogramma’s (middels DIP switches 5 en 6), verrichten een viertraps IuoUoP laad proces bestaande uit een “Bulk” , een “Absorption”, een “Float” en een “Pulse” fase. De volgende afbeelding toont het viertraps laad proces : In de Bulk fase levert de lader de volledige laadstroom en zal de accu tot gemiddeld zo’n 80% opladen wanneer de absorptie spanning is bereikt. Gedurende deze fase lichten Indicatoren 3d (zie hoofdstuk 4.2) en 3c op, afhankelijk van de voortgang. Wanneer de absorptie spanning is bereikt, zal de absorption fase aanvangen waarbij ook indicator 3b op zal lichten. Deze fase zal de overige 20% van de accu capaciteit aanvullen. De uitgangsspanning wordt hierbij constant gehouden en de laadstroom zal afnemen als gevolg het steeds voller worden van de accu. Wanneer de laadstroom is afgenomen tot onder een bepaalde waarde of wanneer de maximale absorption timer is verstreken, zal de float fase aanvangen. Indicator 3a zal oplichten en er klinkt een akoestische melding om aan te geven dat de accu vol is. In deze fase wordt de accu spanning constant gehouden op een waarde welke veilig is voor de accu. Dit zorgt ervoor dat de accu in optimale conditie blijft zolang deze staat aangesloten op de geactiveerde lader. Aangesloten accu belastingen worden direct door de lader gevoed tot aan de maximale uitgangsstroom van de lader. Wanneer meer dan deze maximale stroom wordt gevraagd door de belasting, zal de accu dit moeten 41 Powersine Combi bijleveren wat resulteert in een dalende accuspanning. Vanaf een bepaalde accuspanning, zal de lader terugspringen naar de bulk fase en wederom een compleet viertraps laad proces uitvoeren wanneer de belastingsstroom weer gedaald is tot onder de maximale laadstroom van de lader. Een vierde fase genaamd pulse activeert, zolang de lader opereert in de float fase, elke 7 dagen een kort laadproces van ca. 1 uur. Dit houdt de accu in optimale conditie en verlengd daarnaast de levensduur. De accu kan dus aangesloten blijven op de geactiveerde lader zonder enig risico op overlading. Wanneer de accu temperatuursensor geïnstalleerd is, zal de lader automatisch de laad spanningen compenseren tegen temperatuur. Dit betekent dat de laad spanningen licht stijgen bij lagere temperaturen en dalen bij hogere temperaturen (-30mV/°C bij 12V modellen en -60mV/°C bij 24V modellen). Op deze manier wordt overlading voorkomen wat de levensduur van de accu verlengd. Wanneer de standaard te selecteren laadprogramma’s niet voldoen aan uw eisen, of wanneer afwijkende laadspanningen of stromen nodig zijn, kunt u met de optionele ‘SAMLEXLink to USB communication kit’ uw eigen laadprogramma’s creëren in SAMLEX Dashboard. Tot 8 verschillende laad fases kunnen met elkaar verbonden worden en elke individuele laad fase kan zeer uitgebreid geconfigureerd worden. Vraagt u alstublieft uw SAMLEX leverancier voor meer informatie over de ‘SAMLEXLink to USB communication kit’. 5.2 Het “Equalizen” van een open lood-zuur accu Wanneer u een open lood-zuur accu gebruikt, zou het af en toe equalizen van deze accu aangeraden kunnen worden door de accufabrikant. Dit zou ook kunnen gelden wanneer de open lood-zuur accu te diep ontladen is geweest, of regelmatig onvolledig geladen wordt. Gedurende een equalize laadstap, zal de accu geladen worden tot 15.5V (of 31V bij 24V modellen) bij een gereduceerd uitgangsstroom nivo. Voordat een equalize laadstap gestart wordt, dienen de onderstaande waarschuwingen eerst gelezen te worden : ! LET OP Een Equalize laadstap mag alleen worden verricht op een open lood-zuur accu. Om deze reden laten SAMLEX laders alleen een equalize laadstap toe wanneer de accu type DIP switches ingesteld staan op ‘open lood-zuur’ (Flooded). Andere accu types zoals GEL en AGM raken beschadigd wanneer deze worden ge-equalized. Volg altijd de instructies van de accufabrikant bij het equalizen van open lood-zuur accu’s. Tijdens een equalize laadstap, genereert de accu explosieve gassen. Volg alle accu veiligheidsvoorschriften welke zijn bijgesloten bij deze lader. Ventileer de omgeving rond de accu voldoende en vermijdt vonken en vlammen in de buurt van de accu. Ontkoppel alle belastingen van de accu tijdens een equalize laadstap. De spanning tijdens het equalizen kan namelijk te hoog zijn voor sommige belastingen. 42 Powersine Combi De Powersine Combi kan niet automatisch bepalen wanneer de equalize laadstap beëindigd moet worden. De gebruiker dient het soortelijk gewicht van het zuur gedurende dit proces in de gaten te houden, om het einde van de equalize laadstap te bepalen. De interne 2 uur timer van de Powersine Combi is alleen bedoeld als veiligheidsoptie, maar zou te lang kunnen duren om accu schade te voorkomen. Om deze reden moet het equalizen altijd worden bijgestaan door de gebruiker. Aangezien het equalizen alleen is toegestaan op open lood-zuur accu’s, staat de Powersine Combi deze laadstap alleen toe wanneer het ‘open lood-zuur’ (Flooded) laadprogramma geselecteerd is (zie hoofdstuk 3.3). Hiernaast dient de lader ook eerst een volledig laadproces te hebben afgerond en te opereren in de float fase. Wanneer aan deze twee condities is voldaan, kan de equalize laadstap worden geactiveerd door de verdiepte equalize drukknop aan de onderkant van de lader (zie onderstaande afbeeldingen) voor drie seconden ingedrukt te houden, totdat de laad status indicator gaat knipperen. Modellen : PSC1600-1800 : Modellen : PSC2000-3500 : De lader staat een maximale equalize tijd toe van twee uur, voordat deze automatisch weer terug stapt naar de float fase. Als het soortelijk zuur gewicht nog niet het door de accu fabrikant aangegeven nivo heeft bereikt, kan er een nieuwe twee uur durende equalize laadstap worden gestart door de drukknop wederom voor 3 seconden in te drukken. Hierbij dient continu het soortelijk zuur gewicht in de gaten te worden gehouden. Wanneer dit gewicht correct is, kan de equalize laadstap manueel worden beëindigd door de drukknop kort in te drukken. De lader zal dan weer terug stappen naar de float fase. 43 Powersine Combi 6. STORINGSTABEL Zie de tabel hieronder wanneer u problemen ondervindt met de Powersine Combi en/of de installatie. Probleem Powersine Combi werkt niet. Mogelijke oorzaak Hoofdschakelaar staat in Off (0) positie. Remote switch of Universal Remote Control hebben de Powersine Combi uitgeschakeld. Slecht contact tussen de Powersine Combi DC kabels en de accupolen. Defecte DC zekering. Slechte accu conditie. De lader modus werkt niet (ook de AC transfer switch sluit niet). De AC ingangsspanning of frequentie liggen buiten het bereik of zijn te onstabiel. Lader deel en/of de AC transfer switch zijn gedeactiveerd tijdens het configureren met Dashboard. De accu wordt niet geheel volgeladen Incorrecte instelling van de absorptie spanning. Incorrecte laadstroom instelling. Te veel spanningsverliezen in de accu kabels en/of accu 44 Oplossing Zet de hoofdschakelaar in de ‘I’ of ‘II’ positie. Activeer de Powersine Combi op afstand of controleer DIP switch 8 of 10 voor de correcte instelling. Zorg voor schone accupolen en kabel ogen. Draai alle DC verbindingsschroeven goed aan. Controleer de accu zekering of de interne DC zekering van de Powersine Combi (alleen PSC1600-1800). Vervang de accu. Zorg ervoor dat de AC ingangsspanning tussen de 185V – 270V ligt en de frequentie tussen de 45Hz – 65Hz (uitgaande van de fabrieksinstellingen). Activeer het lader deel en de AC transfer switch weer met behulp van Dashboard. Controleer DIP switch 5 en 6 voor correcte instellingen. Of wijzig de absorptie spanning met behulp van Dashboard. Stel de laadstroom correct af met behulp van de Universal Remote Control of SAMLEX Dashboard. Gemiddeld genomen dient de laadstroom ingesteld te worden op 10%-20% van de totale accu capaciteit. Zorg ervoor dat de accu kabels voldoende capaciteit Powersine Combi aansluitingen. Laadstroom is te laag. Mode indicator LED’s ‘inverter on’, ‘charger on’ en ‘AC in’ geven één flits per keer in rood (accu error). (kwadratuur) hebben. Controleer of alle accu aansluitingen solide en corrosie vrij zijn. Schakel de belasting uit, of ontkoppel deze van de accu. Belasting op de accu verbruikt teveel stroom gedurende het laden. Hoge omgevingstemperatuur Probeer de temperatuur rond de Powersine Combi te verlagen. Lader opereert in de Doe niets. De accu is bijna absorptie laadfase. volledig opgeladen en verbruikt daardoor minder stroom van de lader. Accu spanning is te laag (< 8V@12V of <16V@24V). Accu spanning is te hoog (> 16.5V@12V of >33V@24V). Te hoge rimpelspanning op de DC ingang (manuele herstart noodzakelijk). Accu is defect, vervang deze. Of de accu is zeer diep ontladen. Laat deze dan langzaam herstellen tot boven de 8.5V (17V@24V) zodat de AC transfer switch en lader weer op kunnen starten. Controleer of een externe bron op het DC systeem de accu spanning teveel laat stijgen. Controleer de accu aansluitingen. Reduceer de accukabellengte. Vergroot de accucapaciteit of kabel diameter. Zorg ervoor dat er geen andere bronnen een hoge rimpelspanning produceren op het DC systeem. Alleen mode indicator LED ‘inverter on’ geeft één flits per keer in rood. Accu spanning is te laag (<10V@12V of <20V@24V). Bied een AC signaal aan op de AC ingang en start een laadproces. Wanneer een andere uitschakelspanning gewenst is in ‘Battery protect On’ mode, kan Dashboard gebruikt worden. Alleen mode indicator LED ‘inverter on’ geeft twee flitsen per keer in rood. De omvormer wordt overbelast. Zorg ervoor dat het totale vermogen van de belasting lager is dan het nominale uitgangsvermogen van de 45 Powersine Combi De belasting aan de AC uitgang veroorzaakt een kortsluiting. De belasting(en) aan de AC uitgang veroorzaakt een te grote opstart stroom. Powersine Combi. Zorg ervoor dat de belasting niet defect is. Controleer of de AC bedrading en aansluitingen geen kortsluiting vormen. Probeer de belastingen één voor één in te schakelen i.p.v. tegelijk. In alle andere gevallen is deze belasting te zwaar voor de Powersine Combi en is een groter Powersine Combi model noodzakelijk. Mode indicator LED’s ‘inverter on’ en ‘charger on’ geven drie flitsen per keer in rood. De Powersine Combi is uitgeschakeld vanwege een te hoge temperatuur. Reduceer de AC belasting in omvormer mode. Probeer de omgevingstemperatuur rondom de Powersine Combi te reduceren. Zorg voor een vrije ruimte van minstens 10cm rondom de unit. Blokkeer in geen geval de luchtstroom rondom de Powersine Combi en plaats geen items op of over de unit. Plaats de unit niet in direct zonlicht of in de buurt van warmte producerende apparatuur. Mode indicator LED ‘AC in’ geeft één flits per keer in rood. AC ingangssignaal is present, maar valt buiten de vereiste spanning en frequentie grenzen. Zorg ervoor dat het AC ingangssignaal binnen de 185V- 270V en 45Hz-65Hz valt. Alle mode indicator LED’s ‘inverter on’, ‘charger on’ en ‘AC in’ geven twee flitsen per seconde in rood. (manuele herstart noodzakelijk) Maximale AC transfer switch stroom is overschreden. Reduceer de belasting aan de AC uitgang. Mode indicator LED ‘inverter on’ of ‘charger on’ of ‘AC in’ branden continu in rood. De omvormer mode, de lader mode of de AC transfer switch zijn uitgeschakeld met behulp van SAMLEX Dashboard. Wanneer alleen ‘inverter on’ continu rood brandt. Wanneer gewenst, kunnen deze met behulp van SAMLEX Dashboard weer ingeschakeld worden. 46 De Powersine Combi hoofdschakelaar staat in ‘charger Powersine Combi only’ mode, wat betekent dat de omvormer mode is uitgeschakeld. Nivo indicator brandt rood (omvormer mode). De omvormer is overbelast en zal na een bepaalde tijd automatisch uitschakelen (deze tijd is afhankelijk van de mate van overbelasting). Reduceer de belasting aan de AC uitgang. Alle mode indicator LED’s ‘inverter on’, ‘charger on’ en ‘AC in’ geven vier flitsen per keer in rood. De Powersine Combi is verkeerd aangesloten of defect. Een externe AC bron is aangesloten op de AC uitgang in plaats van de AC ingang. Of retourneer de Powersine Combi voor service. Mode indicator LED ‘charger on’ geeft vijf flitsen per keer in rood. Laad programma fout. De gebruiker heeft een lege of foutief laad programma geselecteerd (‘custom’ laad programma is af fabriek leeg). Een door de gebruiker in SAMLEX Dashboard gemaakt laad programma bevat een fout. Wanneer geen van de bovenstaande oplossingen werken, kunt het beste contact opnemen met een lokale SAMLEX distributeur voor verdere assistentie en/of reparatie van uw Powersine Combi. Haal de Powersine Combi nooit zelf uit elkaar, aangezien er gevaarlijke spanningen aanwezig kunnen zijn aan de binnenzijde. Tevens zal dit direct uw recht op garantie ongeldig verklaren. 47 Powersine Combi 7. TECHNISCHE SPECIFICATIES Parameter Omvormer deel Uitgangsvermogen 1) PSC1600-12-60 Pnom P10minuten Ppiek PSC1800-24-35 1300W 1400W 1600W 1800W 2500W 3000W 230Vac ± 2% / 50Hz ± 0.05% Pure sinusvorm (THD < 5% 1) @ Pnom) 12V 24V 2) 2) 10.5 – 16Vdc 21 – 32Vdc 92% 94% < 10W [2.0W] < 12W [2.0W] Uitgangsspanning / frequentie Uitgangsspanningsvorm DC ingangsspanning (± 3% tol.) Nominaal Bereik Maximale rendement Ruststroom verbruik3) [ASB] Lader deel AC ingangsspanning Maximale continue laadstroom4) Standaard laadspanning (bulk / float @ 25°C) Laad algoritme / programma AC Transfer switch Maximale continue stroom Omschakeltijd (gemiddeld) Algemeen Geschikt voor SAMLEXLink Beveiligingen 185 – 270Vac / 45 – 65Hz / PF > 0.95 60A 35A 14.3V / 13.3V 28.6V / 26.6V IUoUoP, intelligent 4 stage, temp. comp. 16Arms 0ms (inv. → ACin) / < 5ms (ACin → inv.) Ja hoge/lage accuspanning, hoge temperatuur, overbelasting, kortsluiting, hoge rimpelspanning en lage AC ingangsspanning Twee kabels, lengte 1.5 meters, 35mm2 Schroef klemmen 351 x 210 x 114mm 10.7kg IP21 / -20°C .. +50°C / -40°C .. +80°C DC (accu) aansluitingen AC aansluitingen Afmetingen behuizing Gewicht Beschermingsklasse / Aanbev. Omgevingstemperatuur / Opslag temperatuur Normen CE gemarkeerd volgens EMC richtlijn 2004/108/EC en Laagspanningsrichtlijn 2006/95/EC (EN60335-1 en EN60335-2-29). RoHS richtlijn 2002/95/EC N.B. : bovenstaande gegevens kunnen zonder aankondiging van de fabrikant veranderen 1) Gemeten met Ohmse belasting. Vermogensopgaves hebben een tolerantie van ± 10% en nemen af bij toenemende temperatuur (ca. 1.2%/°C vanaf 25°C). 2) Het onder voltage is dynamisch. Deze limiet daalt bij toenemende belasting om spanningsverliezen over kabels en/of aansluitingen te compenseren. 3) Gemeten bij nominale ingangsspanning en 25°C omgevingstemperatuur. 4) Bij hoge omgevingstemperaturen zal de maximum laadstroom automatisch gereduceerd worden. 48 Powersine Combi Parameter Omvormer deel Uitgangsvermogen 1) PSC2000-12-80 Pnom P10minuten Ppiek Uitgangsspanning / frequentie Uitgangsspanningsvorm DC ingangsspanning (± 3% tol.) Nominaal Bereik Maximale rendement Ruststroom verbruik3) [ASB] Lader deel AC ingangsspanning Maximale continue laadstroom4) (Sec. uitgang) Standaard laadspanning (bulk / float @ 25°C) Laad algoritme / programma AC Transfer switch Maximale continue stroom Omschakeltijd (gemiddeld) Algemeen Geschikt voor SAMLEXLink Beveiligingen DC (accu) aansluitingen AC aansluitingen Afmetingen behuizing Gewicht Beschermingsklasse / Aanbev. Omgevingstemperatuur / Opslag temperatuur Normen PSC2500-24-50 1800W 2000W 2100W 2500W 4000W 5500W 230Vac ± 2% / 50Hz ± 0.05% Pure sinusvorm (THD < 5% 1) @ Pnom) 12V 24V 2) 2) 10.5 – 16Vdc 21 – 32Vdc 92% 93% < 20W [3.5W] < 20W [4.0W] 185 – 270Vac / 45 – 65Hz / PF > 0.95 80A (4A) 50A (4A) 14.3V / 13.3V 28.6V / 26.6V IUoUoP, intelligent 4 stage, temp. comp. 30Arms 0ms (inv. → ACin) / < 5ms (ACin → inv.) Ja hoge/lage accuspanning, hoge temperatuur, overbelasting, kortsluiting, hoge rimpelspanning en lage AC ingangsspanning M10 bout verbindingen Schroef klemmen 370 x 431 x 132mm 18.5kg IP21 / -20°C .. +50°C / -40°C .. +80°C CE gemarkeerd volgens EMC richtlijn 2004/108/EC en Laagspanningsrichtlijn 2006/95/EC (EN60335-1 en EN60335-2-29). RoHS richtlijn 2002/95/EC N.B. : bovenstaande gegevens kunnen zonder aankondiging van de fabrikant veranderen 1) Gemeten met Ohmse belasting. Vermogensopgaves hebben een tolerantie van ± 10% en nemen af bij toenemende temperatuur (ca. 1.2%/°C vanaf 25°C). 2) Het onder voltage is dynamisch. Deze limiet daalt bij toenemende belasting om spanningsverliezen over kabels en/of aansluitingen te compenseren. 3) Gemeten bij nominale ingangsspanning en 25°C omgevingstemperatuur. 4) Bij hoge omgevingstemperaturen zal de maximum laadstroom automatisch gereduceerd worden. 49 Powersine Combi Parameter Omvormer deel Uitgangsvermogen 1) PSC3000-12-120 Pnom P10minuten Ppiek PSC3500-24-70 2600W 2800W 3200W 3800W 5000W 6500W 230Vac ± 2% / 50Hz ± 0.05% Pure sinusvorm (THD < 5% 1) @ Pnom) 12V 24V 2) 2) 10.5 – 16Vdc 21 – 32Vdc 92% 93% < 20W [3.5W] < 20W [4.0W] Uitgangsspanning / frequentie Uitgangsspanningsvorm DC ingangsspanning (± 3% tol.) Nominaal Bereik Maximale rendement Ruststroom verbruik3) [ASB] Lader deel AC ingangsspanning Maximale continue laadstroom4)(Sec. uitgang) Standaard laadspanning (bulk / float @ 25°C) Laad algoritme / programma AC Transfer switch Maximale continue stroom Omschakeltijd (gemiddeld) Algemeen Geschikt voor SAMLEXLink Beveiligingen 185 – 270Vac / 45 – 65Hz / PF > 0.95 120A (4A) 70A (4A) 14.3V / 13.3V 28.6V / 26.6V IUoUoP, intelligent 4 stage, temp. comp. 30Arms 0ms (inv. → ACin) / < 5ms (ACin → inv.) Ja hoge/lage accuspanning, hoge temperatuur, overbelasting, kortsluiting, hoge rimpelspanning en lage AC ingangsspanning M10 bout verbindingen Schroef klemmen 370 x 431 x 132mm 19.0kg IP21 / -20°C .. +50°C / -40°C .. +80°C DC (accu) aansluitingen AC aansluitingen Afmetingen behuizing Gewicht Beschermingsklasse / Aanbev. Omgevingstemperatuur / Opslag temperatuur Normen CE gemarkeerd volgens EMC richtlijn 2004/108/EC en Laagspanningsrichtlijn 2006/95/EC (EN60335-1 en EN60335-2-29). RoHS richtlijn 2002/95/EC N.B. : bovenstaande gegevens kunnen zonder aankondiging van de fabrikant veranderen 1) Gemeten met Ohmse belasting. Vermogensopgaves hebben een tolerantie van ± 10% en nemen af bij toenemende temperatuur (ca. 1.2%/°C vanaf 25°C). 2) Het onder voltage is dynamisch. Deze limiet daalt bij toenemende belasting om spanningsverliezen over kabels en/of aansluitingen te compenseren. 3) Gemeten bij nominale ingangsspanning en 25°C omgevingstemperatuur. 4) Bij hoge omgevingstemperaturen zal de maximum laadstroom automatisch gereduceerd worden. 50 Powersine Combi 8. GARANTIE / AANSPRAKELIJKHEID FABRIKANT Samlex Europe (SAMLEX) garandeert dit product vrij van defecten veroorzaakt in de assemblage of door de gebruikte materialen, tot 24 maanden na de aankoop datum. Gedurende deze periode neemt SAMLEX de kosten van eventuele reparatie voor zijn rekening. SAMLEX is niet verantwoordelijk voor de transportkosten van dit product. Deze garantie vervalt wanneer dit product fysiek beschadigd is zowel extern als intern, als er iets aan het oorspronkelijk apparaat veranderd is of als de behuizing door een niet gemachtigd persoon is geopend. Deze garantie dekt geen kosten veroorzaakt door onjuist gebruik1), pogingen om de omvormer zwaar over te belasten of door gebruik in niet geschikte omgevingen. Deze garantie is niet geldig wanneer dit product wordt misbruikt, verwaarloosd, onjuist geïnstalleerd of gerepareerd door iemand anders dan door SAMLEX is aangewezen. De fabrikant is niet verantwoordelijk voor enig verlies, schade of kosten voortvloeiende uit onjuist gebruik of installatie van dit product, gebruik in niet geschikte omgevingen en product storing. Omdat de fabrikant geen controle kan uitvoeren op het gebruik en de installatie (volgens de lokaal geldende voorschriften) van de SAMLEX producten, is de eindgebruiker ten alle tijden aansprakelijk voor het gebruik van de SAMLEX producten. SAMLEX producten zijn niet ontworpen voor toepassing als kritisch component in (medische-) apparatuur of systemen die een potentieel gevaar kunnen vormen voor mens, natuur en milieu. De eindgebruiker is ten alle tijden verantwoordelijk voor de toepassing van SAMLEX produkten in deze applicaties. De fabrikant accepteert geen verantwoordelijkheid voor mogelijke inbreuk op patenten of andere rechten van derden, verbonden aan het gebruik van SAMLEX producten. De fabrikant behoudt het recht om product specificaties te wijzigen zonder voorafgaande aankondiging. 1) - Enkele voorbeelden van onjuist gebruik zijn : Het aanbieden van een te hoge ingangsspanning (DC of AC) Het verkeerd om aansluiten van de akku kabels Het aansluiten van niet geschikte accu’s Mechanisch te zwaar belaste behuizing en/of interne onderdelen, vanwege misbruik of incorrecte verpakking Kontakt met vloeistoffen of oxidatie door condensatie 9. CONFORMITEITSVERKLARING Zie pagina 27 51 www.samlex.com www.samlex-solar.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

Samlexpower PSC1800-24-35 de handleiding

Categorie
Stroomgeneratoren
Type
de handleiding
Deze handleiding is ook geschikt voor