Microlife BP A3 Plus Automatic Blood Pressure Monitor Handleiding

Categorie
Bloeddruk eenheden
Type
Handleiding

Deze handleiding is ook geschikt voor

Microlife BP A3 Plus
IB BP A3 Plus S-V10-1 1321
Revision Date: 2020-02-24
Microlife AG
Espenstrasse 139
9443 Widnau / Switzerland
www.microlife.com
EC
REP
Microlife UAB
P. Lukšio g. 32,
08222 Vilnius
Lithuania
EN 1
ES 8
FR 16
IT 24
DE 32
TR 40
PT 48
NL 56
GR 64
AR 72
Microlife BP A3 Plus BP A3 PlusGuarantee Card
Name of Purchaser / Nom de l'acheteur / Nome
del rivenditore / Name des Käufers / Alıcının adı /
Nombre del comprador / Nome do comprador /
Naam koper / Ονοματεπώνυμο αγοραστή /
Serial Number / Numéro de série / Numero di
serie / Serien-Nr. / Seri numarası / Número de
serie / Número de série / Serienummer / Αριθμός
σειράς /
Date of Purchase / Date d'achat / Data d’acquisto /
Kaufdatum / Satın alma tarihi / Fecha de compra /
Data da compra / Datum van aankoop /
Ημερομηνία αγοράς /
Specialist Dealer / Revendeur / Categoria riven-
ditore / Fachhändler / Uzman satıcı / Distribuidor
especializado / Revendedor autorizado / Specialist
distributeur / Εξειδικευμένος αντιπρόσωποςa /
BP W100
١٢
AR
ﺔﻟﺎﻔﻜﻟا ﺔﻗﺎﻄﺑ
(ﻲﻔﻠﺨﻟا ءﺎﻄﻐﻟا ﺮﻈﻧا) ﺔﻟﺎﻔﻜﻟا ﺔﻗﺎﻄﺑ
:يﺮﺘﺸﻤﻟا ﻢﺳا
:ﻞﻳدﻮﻤﻟا
:ﻞﺴﻠﺴﺘﻟا ﻢﻗر
:ءاﺮﺸﻟا ﺦﻳرﺎﺗ
:ﺺﺘﺨﻤﻟا ﺮﺟﺎﺘﻟا
BP W100
١٢
AR
ﺔﻟﺎﻔﻜﻟا ﺔﻗﺎﻄﺑ
(ﻲﻔﻠﺨﻟا ءﺎﻄﻐﻟا ﺮﻈﻧا) ﺔﻟﺎﻔﻜﻟا ﺔﻗﺎﻄﺑ
:يﺮﺘﺸﻤﻟا ﻢﺳا
:ﻞﻳدﻮﻤﻟا
:ﻞﺴﻠﺴﺘﻟا ﻢﻗر
:ءاﺮﺸﻟا ﺦﻳرﺎﺗ
:ﺺﺘﺨﻤﻟا ﺮﺟﺎﺘﻟا
BP W100
١٢
AR
ﺔﻟﺎﻔﻜﻟا ﺔﻗﺎﻄﺑ
(ﻲﻔﻠﺨﻟا ءﺎﻄﻐﻟا ﺮﻈﻧا) ﺔﻟﺎﻔﻜﻟا ﺔﻗﺎﻄﺑ
:يﺮﺘﺸﻤﻟا ﻢﺳا
:ﻞﻳدﻮﻤﻟا
:ﻞﺴﻠﺴﺘﻟا ﻢﻗر
:ءاﺮﺸﻟا ﺦﻳرﺎﺗ
:ﺺﺘﺨﻤﻟا ﺮﺟﺎﺘﻟا
BP W100
١٢
AR
ﺔﻟﺎﻔﻜﻟا ﺔﻗﺎﻄﺑ
(ﻲﻔﻠﺨﻟا ءﺎﻄﻐﻟا ﺮﻈﻧا) ﺔﻟﺎﻔﻜﻟا ﺔﻗﺎﻄﺑ
:يﺮﺘﺸﻤﻟا ﻢﺳا
:ﻞﻳدﻮﻤﻟا
:ﻞﺴﻠﺴﺘﻟا ﻢﻗر
:ءاﺮﺸﻟا ﺦﻳرﺎﺗ
:ﺺﺘﺨﻤﻟا ﺮﺟﺎﺘﻟا
BP A3 Plus
1BP A3 Plus
EN
Display
Read the instructions carefully before using this device.
Type BF applied part
Intended use:
This oscillometric blood pressure monitor is intended for measuring
non-invasive blood pressure in people aged 12 years or older.
It is clinically validated in patients with hypertension, hypotension,
diabetes, pregnancy, pre-eclampsia, atherosclerosis, end-stage
renal disease, obesity and the elderly.
Dear Customer,
This device was developed in collaboration with physicians and
clinical tests carried out prove its measurement accuracy to be of
a very high standard.*
If you have any questions, problems or want to order spare parts
please contact your local Microlife-Customer Service. Your dealer
or pharmacy will be able to give you the address of the Microlife
dealer in your country. Alternatively, visit the internet at
www.microlife.com where you will find a wealth of invaluable infor-
mation on our products.
Stay healthy – Microlife AG!
* This device uses the same measuring technology as the award
winning «BP 3BTO-A» model tested according to the British and
Irish Hypertension Society (BIHS) protocol.
Microlife BP A3 Plus
EN
1
ON/OFF button
2
Display
3
Cuff Socket
4
Battery Compartment
5
Mains Adapter Socket
6
Cuff
7
Cuff Connector
8
MAM Switch
9
User Switch
AT
M-button (memory)
AK
Time Button
AL
User Indicator
AM
Battery Display
AN
Date/Time
AO
Systolic Value
AP
Diastolic Value
AQ
Pulse Rate
AR
Traffic Light Indicator
AS
MAM Interval Time
BT
Pulse Indicator
BK
Cuff Check Indicator
BL
MAM Mode
BM
Irregular Heartbeat (IHB) Symbol
BN
Arm Movement Indicator
BO
Stored Value
Keep dry
2
Table of Contents
1. Important Facts about Blood Pressure and Self-Measure-
ment
How do I evaluate my blood pressure?
2. Using the Device for the First Time
Inserting the batteries
Setting the date and time
Selecting the correct cuff
Selecting the user
Selecting standard or MAM mode
MAM mode (highly recommended)
3. Taking a Blood Pressure Measurement
How not to store a reading
4. Appearance of the Irregular Heartbeat (IHB) Symbol
5. Traffic Light Indicator in the Display
6. Data Memory
Viewing the stored values
Memory full
Clearing all values
7. Battery Indicator and Battery change
Low battery
Flat battery – replacement
Which batteries and which procedure?
Using rechargeable batteries
8. Using a Mains Adapter
9. Error Messages
10. Safety, Care, Accuracy Test and Disposal
Safety and protection
Device care
Cleaning the cuff
Accuracy test
Disposal
11. Guarantee
12. Technical Specifications
Guarantee Card (see Back Cover)
1. Important Facts about Blood Pressure and Self-
Measurement
Blood pressure is the pressure of the blood flowing in the
arteries generated by the pumping of the heart. Two values, the
systolic (upper) value and the diastolic (lower) value, are
always measured.
The device indicates the pulse rate (the number of times the
heart beats in a minute).
Permanently high blood pressure values can damage your
health and must be treated by your doctor!
Always discuss your values with your doctor and tell him/her if
you have noticed anything unusual or feel unsure. Never rely
on single blood pressure readings.
There are several causes of excessively high blood pressure
values. Your doctor will explain them in more detail and offer
treatment where appropriate. Besides medication, weight loss
and exercise can also lower your blood pressure.
Under no circumstances should you alter the dosages of
drugs or initiate a treatment without consulting your doctor.
Depending on physical exertion and condition, blood pressure
is subject to wide fluctuations as the day progresses. You
should therefore take your measurements in the same
quiet conditions and when you feel relaxed! Take at least
two readings every time (in the morning and in the evening) and
average the measurements.
It is quite normal for two measurements taken in quick succes-
sion to produce significantly different results. Therefore we
recommend using the MAM technology.
Deviations between measurements taken by your doctor or in
the pharmacy and those taken at home are quite normal, as
these situations are completely different.
Several measurements
provide much more reliable information
about your blood pressure than just one single measurement.
Therefore we recommend using the MAM technology.
Leave a small break of at least 15 seconds between two
measurements.
If you suffer from a cardiac arrhythmia consult with your doctor
before using the device. See also chapter «Appearance of the
Irregular Heartbeat (IHB) Symbol» of this user manual.
The pulse display is not suitable for checking the
frequency of heart pacemakers!
3BP A3 Plus
EN
If you are pregnant, you should monitor your blood pressure
regularly as it can change drastically during this time.
This monitor is specially tested for use in pregnancy and
pre-eclampsia. When you detect unusual high readings in
pregnancy, you should measure after a short while again
(eg. 1 hour). If the reading is still too high, consult your
doctor or gynecologist.
How do I evaluate my blood pressure?
The higher value is the one that determines the evaluation.
Example: a blood pressure value of 140/80 mmHg or a value of
130/90 mmHg indicates «blood pressure too high».
2. Using the Device for the First Time
Inserting the batteries
After you have unpacked your device, first insert the batteries. The
battery compartment
4
is on the bottom of the device. Insert the
batteries (
4
x 1.5 V, size
AA
), thereby observing the indicated
polarity.
Setting the date and time
1. After the new batteries are fitted, the year number flashes in the
display. You can set the year by pressing the M-button AT. To
confirm and then set the month, press the time button AK.
2. Press the M-button to set the month. Press the time button to
confirm and then set the day.
3. Follow the instructions above to set the day, hour and minutes.
4. Once you have set the minutes and pressed the time button, the
date and time are set and the time is displayed.
5. If you want to change the date and time, press and hold the time
button down for approx. 3 seconds until the year number starts
to flash. Now you can enter the new values as described above.
Selecting the correct cuff
Microlife offers different cuff sizes. Select the cuff size to match the
circumference of your upper arms (measured by close fitting in the
centre of the upper arm).
Optional preformed cuffs «Easy» are available for better
fitting and comfort.
Only use Microlife cuffs.
Contact your local Microlife Service if the enclosed cuff 6 does
not fit.
Connect the cuff to the device by inserting the cuff connector 7
into the cuff socket 3 as far as it will go.
Selecting the user
This device allows to store the results for 2 individual users.
Before each measurement, set the user switch 9 for the
intended user: user 1 or user 2.
User 1: slide the user switch 9 upwards to the user 1 icon.
User 2: slide the user switch 9 downwards to the user 2 icon.
The first person to measure should select user 1.
Selecting standard or MAM mode
This device enables you to select either standard (standard single
measurement) or MAM mode (automatic triple measurement). To
select standard mode, slide the MAM switch 8 on the side of the
device downwards to position «1» and to select MAM mode, slide
this switch upwards to position «3».
MAM mode (highly recommended)
In MAM mode, 3 measurements are automatically taken in
succession and the result is then automatically analysed and
displayed. Because the blood pressure constantly fluctuates, a
result determined in this way is more reliable than one produced
by a single measurement.
Table for classifying home blood pressure values in adults in
accordance with the international Guidelines (ESH, ESC, JSH).
Data in mmHg.
Range Systolic Diastolic
Recommenda-
tion
1. blood pressure
normal
< 120 < 74 Self-check
2. blood pressure
optimum
120 - 129 74 - 79 Self-check
3. blood pressure
elevated
130 - 134 80 - 84 Self-check
4. blood pressure too
high
135 - 159 85 - 99 Seek medical
advice
5. blood pressure
dangerously high
160 100 Urgently seek
medical advice!
Cuff size for circumference of upper arm
S 17 - 22 cm
M 22 - 32 cm
M - L 22 - 42 cm
L 32 - 42 cm
L - XL 32 - 52 cm
4
When you select the 3 measurements, the MAM-symbol BL
appears in the display.
The bottom, right hand section of the display shows a 1, 2 or 3 to
indicate which of the 3 measurements is currently being taken.
There is a break of 15 seconds between the measurements.
A count down indicates the remaining time.
The individual results are not displayed. Your blood pressure
will only be displayed after all 3 measurements are taken.
Do not remove the cuff between measurements.
If one of the individual measurements was questionable, a
fourth one is automatically taken.
3. Taking a Blood Pressure Measurement
Checklist for taking a reliable measurement
1. Avoid activity, eating or smoking immediately before the
measurement.
2. Sit down on a back-supported chair and relax for 5 minutes.
Keep the feet flat on the floor and do not cross your legs.
3. Always measure on the same arm (normally left). It is recom-
mended that doctors perform double arm measurements on a
patients first visit in order to determine which arm to measure in
the future. The arm with the higher blood pressure should be
measured.
4. Remove close-fitting garments from the upper arm. To avoid
constriction, shirt sleeves should not be rolled up - they do not
interfere with the cuff if they are laid flat.
5. Always ensure that the correct cuff size is used (marking on the
cuff).
Fit the cuff closely, but not too tight.
Make sure that the cuff is positioned 1-2 cm above the elbow.
The artery mark on the cuff (ca. 3 cm long bar) must lie over
the artery which runs down the inner side of the arm.
Support your arm so it is relaxed.
Ensure that the cuff is at the same height as your heart.
6. Press the ON/OFF button 1 to start the measurement.
7. The cuff will now pump up automatically. Relax, do not move
and do not tense your arm muscles until the measurement
result is displayed. Breathe normally and do not talk.
8. When the correct pressure is reached, the pumping stops and the
pressure falls gradually. If the required pressure was not reached,
the device will automatically pump some more air into the cuff.
9. During the measurement, the pulse indicator BT flashes in the
display.
10.The result, comprising the systolic AO and the diastolic AP
blood pressure and the pulse rate AQ is displayed. Note also the
explanations on further display symbols in this booklet.
11.When the device has finished measuring, remove the cuff.
12.Switch off the device. (The monitor does switch off automati-
cally after approx. 1 min.).
How not to store a reading
As soon as the reading is displayed press and hold the ON/OFF
button 1 until «M» BO is flashing. Confirm to delete the reading by
pressing the M-button AT.
You can stop the measurement at any time by pressing the
ON/OFF button (e.g. if you feel uneasy or an unpleasant
pressure sensation).
If the systolic blood pressure is known to be very high
,
it can be an advantage to set the pressure individually. Press
the ON/OFF button after the monitor has been pumped up to
a level of approx. 30 mmHg (shown on the display). Keep the
button pressed until the pressure is about 40 mmHg above
the expected systolic value – then release the button.
4. Appearance of the Irregular Heartbeat (IHB) Symbol
This symbol BM indicates that an irregular heartbeat was detected.
In this case, the measured blood pressure may deviate from your
actual blood pressure values. It is recommended to repeat the
measurement.
5. Traffic Light Indicator in the Display
The bars on the left-hand edge of the display AR show you the
range within which the indicated blood pressure value lies.
Depending on the height of the bar, the readout value is either
within the optimum (green), elevated (yellow), too high (orange) or
dangerously high (red) range. The classification corresponds to
the 4 ranges in the table as defined by the international guidelines
(ESH, ESC, JSH), as described in «Section 1.».
Information for the doctor in case of repeated appearance of
the IHB symbol:
This device is an oscillometric blood pressure monitor that also
measures the pulse during blood pressure measurement and
indicates when the heart rate is irregular.
5BP A3 Plus
EN
6. Data Memory
This device automatically stores up to 99 measurement values for
each of the 2 users.
Viewing the stored values
Select either user 1 or 2 with the user switch 9.
Press the M-button AT briefly, when the device is switched off. The
display first shows «M» BO and «A», which stands for the average
of all stored values.
Pressing the M-button again displays the previous value. Pressing
the M-button repeatedly enables you to move from one stored
value to another.
Memory full
Pay attention that the maximum memory capacity of 99
memories per user is not exceeded. When the 99 memory
is full, the oldest value is automatically overwritten with
the 100th value. Values should be evaluated by a doctor
before the memory capacity is reached – otherwise data will
be lost.
Clearing all values
Make sure the correct user is activated.
1. Select either user 1 or 2 with the user switch 9, when the
device is switched off.
2. Hold down the M-button
AT
until «
CL
» appears and then release
the button.
3. Press the M-button while «CL» is flashing to permanently clear
all values of the selected user.
Cancel deletion: press ON/OFF button 1 while «CL» is
flashing.
Individual values cannot be cleared.
7. Battery Indicator and Battery change
Low battery
When the batteries are approximately ¾ empty the battery symbol
AM
will flash as soon as the device is switched on (partly filled battery
displayed). Although the device will continue to measure reliably, you
should obtain replacement batteries.
Flat battery – replacement
When the batteries are flat, the battery symbol AM will flash as soon
as the device is switched on (flat battery displayed). You cannot
take any further measurements and must replace the batteries.
1. Open the battery compartment 4 on the bottom of the device.
2. Replace the batteries – ensure correct polarity as shown by the
symbols in the compartment.
3. To set date and time, follow the procedure described in
«Section 2.».
The memory retains all values although date and time must
be reset – the year number therefore flashes automatically
after the batteries are replaced.
Which batteries and which procedure?
Use 4 new, long-life 1.5 V, size AA alkaline batteries.
Do not use batteries beyond their date of expiry.
Remove batteries if the device is not going to be used for a
prolonged period.
Using rechargeable batteries
You can also operate this device using rechargeable batteries.
Only use «NiMH» type reusable batteries.
Batteries must be removed and recharged when the flat
battery symbol appears. They should not remain inside the
device as they may become damaged (total discharge as a
result of low use of the device, even when switched off).
Always remove the rechargeable batteries if you do not
intend to use the device for a week or more.
Batteries cannot be charged in the blood pressure monitor.
Recharge batteries in an external charger and observe the
information regarding charging, care and durability.
8. Using a Mains Adapter
You can operate this device using the Microlife mains adapter
(DC 6V, 600 mA).
Only use the
Microlife
mains adapter available as an original
accessory appropriate for your supply voltage.
Ensure that neither the mains adapter nor the cable are
damaged.
1. Plug the adapter cable into the mains adapter socket 5 in the
blood pressure monitor.
2. Plug the adapter plug into the wall socket.
When the mains adapter is connected, no battery current is
consumed.
6
9. Error Messages
If an error occurs during the measurement, the measurement is
interrupted and an error message, e.g. «ERR 3», is displayed.
* Please immediately consult your doctor, if this or any other
problem occurs repeatedly.
If you think the results are unusual, please read through the
information in «Section 1.» carefully.
10.Safety, Care, Accuracy Test and Disposal
Safety and protection
Follow instructions for use. This document provides important
product operation and safety information regarding this device.
Please read this document thoroughly before using the device
and keep for future reference.
This device may only be used for the purposes described in
these instructions. The manufacturer cannot be held liable for
damage caused by incorrect application.
This device comprises sensitive components and must be
treated with caution. Observe the storage and operating condi-
tions described in the «Technical Specifications» section.
Protect it from:
- water and moisture
- extreme temperatures
- impact and dropping
- contamination and dust
- direct sunlight
- heat and cold
The cuffs are sensitive and must be handled with care.
Do not exchange or use any other kind of cuff or cuff connector
for measuring with this device.
Only pump up the cuff once fitted.
Do not use this device close to strong electromagnetic fields
such as mobile telephones or radio installations. Keep a
minimum distance of 3.3 m from such devices when using this
device.
Do not use this device if you think it is damaged or notice
anything unusual.
Never open this device.
If the device is not going to be used for a prolonged period the
batteries should be removed.
Read the additional safety information provided within the indi-
vidual sections of this instruction manual.
The measurement results given by this device is not a diag-
nosis. It is not replacing the need for the consultation of a physi-
cian, especially if not matching the patient’s symptoms. Do not
rely on the measurement result only, always consider other
potentially occurring symptoms and the patient’s feedback.
Calling a doctor or an ambulance is advised if needed.
Error Description Potential cause and remedy
«ERR 1» Signal too
weak
The pulse signals on the cuff are too
weak. Re-position the cuff and repeat the
measurement.*
«ERR 2»
BN
Error signal During the measurement, error signals
were detected by the cuff, caused for
instance by movement or muscle
tension. Repeat the measurement,
keeping your arm still.
«ERR 3»
BK
No pressure
in the cuff
An adequate pressure cannot be gener-
ated in the cuff. A leak may have
occurred. Check that the cuff is correctly
connected and is not too loose. Replace
the batteries if necessary. Repeat the
measurement.
«ERR 5» Abnormal
result
The measuring signals are inaccurate
and no result can therefore be displayed.
Read through the checklist for
performing reliable measurements and
then repeat the measurement.*
«ERR 6» MAM Mode There were too many errors during the
measurement in MAM mode, making it
impossible to obtain a final result. Read
through the checklist for performing reli-
able measurements and then repeat the
measurement.*
«HI» Pulse or cuff
pressure
too high
The pressure in the cuff is too high (over
299 mmHg) OR the pulse is too high
(over 200 beats per minute). Relax for 5
minutes and repeat the measurement.*
«LO» Pulse too
low
The pulse is too low (less than 40 beats
per minute). Repeat the measurement.*
7BP A3 Plus
EN
Ensure that children do not use this device unsupervised;
some parts are small enough to be swallowed. Be aware of
the risk of strangulation in case this device is supplied with
cables or tubes.
Device care
Clean the device only with a soft, dry cloth.
Cleaning the cuff
Carefully remove spots on the cuff with a damp cloth and soapsuds.
WARNING: Do not wash the cuff in a washing machine or
dishwasher!
Accuracy test
We recommend this device is tested for accuracy every 2 years or
after mechanical impact (e.g. being dropped). Please contact your
local Microlife-Service to arrange the test (see foreword).
Disposal
Batteries and electronic devices must be disposed of in
accordance with the locally applicable regulations, not with
domestic waste.
11.Guarantee
This device is covered by a 5 year guarantee from the date of
purchase. During this guarantee period, at our discretion, Microlife
will repair or replace the defective product free of charge.
Opening or altering the device invalidates the guarantee.
The following items are excluded from the guarantee:
Transport costs and risks of transport.
Damage caused by incorrect application or non-compliance
with the instructions for use.
Damage caused by leaking batteries.
Damage caused by accident or misuse.
Packaging/storage material and instructions for use.
Regular checks and maintenance (calibration).
Accessories and wearing parts: Batteries, power adapter
(optional).
The cuff is covered by a functional guarantee (bladder tightness)
for 2 years.
Should guarantee service be required, please contact the dealer
from where the product was purchased, or your local Microlife
service. You may contact your local Microlife service through our
website:
www.microlife.com/support
Compensation is limited to the value of the product. The guarantee
will be granted if the complete product is returned with the original
invoice. Repair or replacement within guarantee does not prolong
or renew the guarantee period. The legal claims and rights of
consumers are not limited by this guarantee.
12.Technical Specifications
This device complies with the requirements of the Medical Device
Directive 93/42/EEC.
Technical alterations reserved.
Operating conditions:
10 - 40 °C / 50 - 104 °F
15 - 95 % relative maximum humidity
Storage conditions:
-20 - +55 °C / -4 - +131 °F
15 - 95 % relative maximum humidity
Weight:
368
g (including batteries)
Dimensions:
143 x 85 x 58
mm
Measuring procedure:
oscillometric, corresponding to Korotkoff
method: Phase I systolic, Phase V diastolic
Measurement range:
20 - 280
mmHg – blood pressure
40 - 200 beats per minute – pulse
Cuff pressure display
range:
0 - 299 mmHg
Resolution:
1 mmHg
Static accuracy:
pressure within ± 3 mmHg
Pulse accuracy:
± 5 % of the readout value
Voltage source:
4 x 1.5 V alkaline batteries; size AA
Mains adapter DC 6V, 600 mA (optional)
Battery lifetime: approx. 920 measurements
(using new batteries)
IP Class: IP20
Reference to
standards:
EN 1060-1 /-3 /-4; IEC 60601-1;
IEC 60601-1-2 (EMC); IEC 60601-1-11
Expected service life: Device: 5 years or 10000 measurements
Accessories: 2 years
8
Pantalla
Lea atentamente las instrucciones antes de utilizar este
dispositivo.
Pieza aplicada tipo BF
Uso previsto:
Este monitor de presión arterial oscilométrico está diseñado para
medir la presión arterial no invasiva en personas de 12 años o más.
Está clínicamente validado en pacientes con hipertensión, hipo-
tensión, diabetes, embarazo, preeclampsia, aterosclerosis, enfer-
medad renal en etapa terminal, obesidad y adultos mayores.
Estimado cliente,
Este dispositivo ha sido desarrollado en colaboración con médicos
y su muy alta precisión ha sido probada en ensayos clínicos.*
Si tiene cualquier pregunta o problema o si desea pedir piezas de
recambio, no dude en contactar con su servicio de atención al
cliente de Microlife local. Su distribuidor o farmacia podrá indicarle
la dirección del distribuidor de Microlife en su país. También puede
visitarnos en Internet en www.microlife.com donde encontrará
información útil sobre nuestros productos.
¡Cuide su salud con Microlife AG!
* Este dispositivo usa la misma tecnología de medición que el
premiado modelo «BP 3BTO-A» probado de acuerdo con el proto-
colo de la Sociedad Británica e Irlandesa de Hipertensión (BIHS).
Microlife BP A3 Plus
ES
1
Botón ON/OFF (Encendido/Apagado)
2
Pantalla
3
Enchufe para manguito
4
Compartimento de baterías
5
Enchufe para adaptador de corriente
6
Brazalete
7
Conector del manguito
8
Interruptor MAM
9
Interruptor de cambio de usuario
AT
Botón M (Memoria)
AK
Botón Hora
AL
Indicador de usuario
AM
Indicador de batería
AN
Fecha/Hora
AO
Valor sistólico
AP
Valor diastólico
AQ
Frecuencia del pulso
AR
Indicador de semáforo
AS
Tiempo de intervalo MAM
BT
Indicador del pulso
BK
Indicador de comprobación del manguito
BL
Modo MAM
BM
Símbolo de latidos irregulares (IHB)
BN
Indicador de movimiento del brazo
BO
Valor guardado
Mantener en lugar seco
9BP A3 Plus
ES
Índice
1. Datos importantes acerca de la presión arterial y la auto-
medición
¿Cómo he de evaluar mi presión arterial?
2. Uso del dispositivo por primera vez
Colocar las baterías
Ajuste de fecha y hora
Elegir el manguito correcto
Seleccionar el usuario
Seleccionando el modo estándar o MAM
Modo MAM (altamente recomendado)
3. Medición de la presión arterial
Procedimiento para no guardar la lectura
4. Apariencia del símbolo de latidos irregulares (IHB)
5. Indicador de semáforo en la pantalla
6. Memoria de datos
Ver los valores guardados
Memoria llena
Borrar todos los valores
7. Indicador de baterías y cambio de baterías
Baterías con poca carga
Baterías descargadas – cambio
¿Qué baterías y qué procedimiento?
Uso de baterías recargables
8. Uso de un adaptador de corriente
9. Mensajes de error
10. Seguridad, cuidado, control de precisión y eliminación de
residuos
Seguridad y protección
Cuidado del dispositivo
Limpieza del brazalete
Control de precisión
Eliminación de residuos
11. Garantía
12. Especificaciones técnicas
Tarjeta de garantía (véase reverso)
1. Datos importantes acerca de la presión arterial y la
automedición
La presión arterial es la presión de la sangre que circula por
las arterias, generada por el bombeo del corazón. Se miden
siempre dos valores, el valor sistólico (superior) y el valor
diastólico (inferior).
El dispositivo indica también la frecuencia del pulso (el
número de latidos del corazón en un minuto).
¡Una presión arterial permanentemente alta puede perju-
dicar su salud y debe ser tratada por su médico!
Consulte siempre con su médico los valores medidos y comén-
tele si ha notado algo inusual o si tiene alguna duda. No confíe
nunca en una sola lectura de presión arterial.
Existen muchas causas de valores de presión arterial exce-
sivamente altos. Su médico se las explicará en detalle y, en
caso de necesidad, le ofrecerá el tratamiento adecuado.
Además de la medicación, la pérdida de peso y el ejercicio
físico también pueden disminuir la presión arterial.
Bajo ninguna circunstancia debe modificar las dosis de medi-
camentos o iniciar un tratamiento sin consultar a su médico
Dependiendo de la condición y el esfuerzo físico, la presión arte-
rial está sujeta a amplias fluctuaciones durante el transcurso del
día.
¡Por esta razón, debe realizar la medición siempre en las
mismas condiciones de tranquilidad y estando relajado!
Realice dos lecturas cada vez (por la mañana y por la noche) y
haga una media de los resultados de las mediciones.
Es completamente normal que dos mediciones tomadas en rápida
sucesión puedan producir
resultados que difieran
significativa-
mente. Por ello recomendamos el uso de la tecnología MAM.
Las diferencias entre las mediciones tomadas por su médico
o en la farmacia y las tomadas en casa son muy normales,
debido a que estas situaciones son completamente diferentes.
Varias mediciones
proporcionan información más fiable sobre la
presión arterial que una sola medición. Por ello recomendamos el
uso de la tecnología MAM.
Deje pasar un breve intervalo de tiempo de al menos
15 segundos entre dos mediciones.
Si sufre una arritmia cardíaca, consulte con su médico antes de
usar el dispositivo. Consulte también el capítulo «Apariencia
del símbolo de latidos irregulares (IHB)» de este manual del
usuario.
¡El indicador de pulsaciones no es apropiado para
comprobar la frecuencia de los marcapasos!
10
Si está
embarazada
, debe controlar su presión arterial con regula-
ridad, ya que puede cambiar drásticamente durante este tiempo.
Este monitor está especialmente probado para su uso en el
embarazo y la preeclampsia. Cuando detecta altas lecturas
inusuales en el embarazo, debe medir después de un
tiempo breve (por ejemplo, 1 hora). Si la lectura es dema-
siado alta, consulte a su médico o ginecólogo.
¿Cómo he de evaluar mi presión arterial?
El valor superior es el que determina la evaluación. Ejemplo: un
valor de la presión arterial de 140/80 mm Hg o 130/90 mm Hg
indica «presión arterial demasiado alta».
2. Uso del dispositivo por primera vez
Colocar las baterías
Después de desembalar el dispositivo, en primer lugar, inserte las
baterías. El compartimento de las baterías 4 está en la parte infe-
rior del dispositivo. Inserte las baterías (4 x 1,5 V, tamaño AA) de
acuerdo con las marcas de polaridad indicadas.
Ajuste de fecha y hora
1. Una vez activadas las baterías, el número del año parpadea en
la pantalla. Ajuste el año pulsando el botón M AT. Para confir-
marlo y ajustar a continuación el mes, pulse el botón Hora AK.
2. Ahora puede ajustar el mes usando el botón M. Pulse el botón
Hora para confirmar y, a continuación, ajuste el día.
3. Por favor, siga las instrucciones anteriores para ajustar el día,
la hora y los minutos.
4. Una vez que haya ajustado los mi
nutos y pulsado el botón Hora,
la fecha y la hora quedan estable
cidas y se visualiza la hora.
5. Si desea cambiar la fecha y la hora, pulse y mantenga pulsado
el botón Hora durante aprox. 3 segundos hasta que comience
a parpadear el número del año. Ahora, podrá introducir los
nuevos valores tal como se ha descrito anteriormente.
Elegir el manguito correcto
Microlife ofrece diferentes tamaños de manguitos. Elija el tamaño
de manguito adecuado según la circunferencia de su brazo
(medida de forma ajustada en el centro del brazo).
Para un mejor ajuste y comodidad, hay manguitos prefor-
mados «Easy» disponibles.
Use únicamente manguitos Microlife.
Contacte su servicio al cliente de Microlife local, si el manguito
6 incluido no es el adecuado para usted.
Conecte el manguito al dispositivo insertando el conector
7
del
manguito en el enchufe
3
del manguito hasta que no entre más.
Seleccionar el usuario
Este dispositivo permite almacenar los resultados de 2 usuarios.
Antes de cada medición, seleccione con el interruptor de
cambio de usuario 9 el usuario que desee: usuario 1 ó 2.
Usuario 1: deslice hacia arriba el interruptor de cambio de
usuario 9 para seleccionar el icono de usuario 1.
Usuario 2: deslice hacia abajo el interruptor de cambio de
usuario 9 para seleccionar el icono de usuario 2.
La primera persona que realice la medición debe selec-
cionar usuario 1.
Seleccionando el modo estándar o MAM
Este dispositivo le permite seleccionar el modo estándar (medi-
ción sencilla estándar) o el modo MAM (medición triple automá-
tica). Para seleccionar el modo estándar, deslice el interruptor
MAM 8 situado en la parte lateral del dispositivo hacia abajo a la
posición «1», y para seleccionar el modo MAM, deslice el inte-
rruptor hacia arriba a la posición «3».
Modo MAM (altamente recomendado)
En el modo MAM, se efectúan automáticamente 3 mediciones
sucesivas y, después, se analiza y se visualiza automática-
Tabla de clasificación de los valores de la presión arterial en
adultos según las Normas Internacionales (ESH, ESC, JSH).
Datos en mmHg.
Nivel Sistólico
Diastó-
lico Recomendación
1. presión arterial
normal
< 120 < 74 Autocontrol
2. presión arterial
óptima
120 - 129 74 - 79 Autocontrol
3. presión arterial
elevada
130 - 134 80 - 84 Autocontrol
4. presión arterial
demasiado alta
135 - 159 85 - 99 Acudir al médico
5.
presión arterial peli-
grosamente alta
160 100 ¡Acudir urgente-
mente al médico!
Tamaño de manguito para una circunferencia del brazo
S 17 - 22 cm
M 22 - 32 cm
M - L 22 - 42 cm
L 32 - 42 cm
L - XL 32 - 52 cm
11BP A3 Plus
ES
mente el resultado. Debido a que la tensión arterial fluctúa
constantemente, un resultado determinado de esta manera es
más fiable que uno obtenido por una medición sencilla.
Cando seleccione las 3 mediciones, el símbolo MAM BL apare-
cerá en la pantalla.
En la parte inferior izquierda de la pantalla aparecen 1, 2 o 3
para indicar cuál de las 3 mediciones se está realizando en ese
momento.
Hay un descanso de 15 segundos entre las mediciones. Una
cuenta regresiva indica el tiempo restante.
Los resultados individuales no se visualizan. Su presión arterial sólo
se visualizará una vez que se hayan efectuado las 3 mediciones.
No retire el manguito entre las mediciones.
Si una de las mediciones individuales ha sido dudosa, se toma
automáticamente una cuarta.
3. Medición de la presión arterial
Lista de chequeo para efectuar una medición fiable
1. Evite comer o fumar, así como cualquier otra actividad inmedia-
tamente antes de la medición.
2. Siéntese en una silla con respaldo y relájese durante 5 minutos.
Mantenga los pies planos sobre el piso y no cruce las piernas.
3. Efectúe la medición siempre en el mismo brazo (normal-
mente en el izquierdo). Es recomendable que su médico realice
dos mediciones en cada brazo durante la primera visita para
determinar de qué brazo se tomarán las mediciones en el
futuro. Las mediciones se deben efectuar en el brazo con
presión arterial más alta.
4. Quítese las prendas de vestir ajustadas a su brazo. Para evitar
la constricción, no se deben arremangar las mangas de
camisa, ya que no interfieren con el manguito si se encuentran
en contacto con el brazo.
5. Asegúrese de utilizar el tamaño correcto del manguito
(marcado en el manguito).
Coloque el manguito de tal forma que esté ajustado, pero
que no quede demasiado apretado.
Asegúrese de que el manguito esté colocado 1-2 cm por
encima del codo.
La
marca de la arteria
en el manguito (barra larga de 3 cm) debe
descansar sobre la arteria que va en el lado interior del brazo.
Coloque el brazo de tal forma que esté relajado.
Asegúrese de que el manguito se encuentre a la misma
altura que su corazón.
6. Presione el botón ON/OFF 1 para iniciar la medición.
7. Ahora, el manguito se inflará automáticamente. Relájese, no se
mueva y no tense los músculos del brazo hasta que se visualice
el resultado de la medición. Respire normalmente y no hable.
8. Una vez alcanzada la presión correcta, el inflado se detiene y
la presión disminuye gradualmente. Si no se alcanzó la presión
necesaria, el dispositivo bombeará automáticamente más aire
al manguito.
9. Durante la medición, el indicador de pulso BT parpadea en la
pantalla.
10.Se visualiza el resultado compuesto por la sistólica AO y el arte-
rial diastólica AP y la frecuencia del pulso AQ.
11.Retire el manguito cuando la medición haya terminado.
12.Desconecte el dispositivo. (El tensiómetro se apaga automáti-
camente al cabo de aprox. 1 min).
Procedimiento para no guardar la lectura
Cuando la lectura aparezca en la pantalla mantenga pulsado el
botón ON/OFF 1 hasta que «M» BO parpadee. Confirme que
desea borrar la lectura pulsando el botón M AT.
La medición se puede detener en cualquier momento presio-
nando el botón ON/OFF (p. ej., si no se encuentra bien o en
caso de tener una sensación de presión desagradable).
Cuando se sabe que la presión arterial sistólica es muy
alta, puede resultar ventajoso ajustar la presión individual-
mente. Pulse el botón ON/OFF una vez que el tensiómetro
se haya inflado hasta un nivel de aprox. 30 mm Hg (repre-
sentado en la pantalla). Mantenga pulsado el botón hasta
que la presión esté aprox. 40 mm Hg por encima del valor
sistólico esperado y entonces suelte el botón.
4. Apariencia del símbolo de latidos irregulares (IHB)
Este símbolo BM indica que se detectó un latido cardíaco irregular.
En este caso, la presión arterial medida puede diferir de sus
valores reales de presión arterial. Se recomienda repetir la medi-
ción.
Información para su doctor en caso de aparición repetida
del símbolo IHB
Este dispositivo es un monitor oscilométrico de presión arterial
que también mide el pulso durante la medición de la presión
arterial e indica cuándo el ritmo cardiaco es irregular.
12
5. Indicador de semáforo en la pantalla
Las barras en el borde izquierdo de la pantalla
AR
muestran el rango
de valores de la presión arterial. Dependiendo de la altura de la
barra, el valor indicado es óptimo (verde), elevado (amarillo), dema-
siado alto (naranja) o peligrosamente alto (rojo). Esta clasificación
se corresponde con los 4 rangos definidos por las normas interna-
cionales (
ESH, ESC, JSH
) e indicados en la tabla del «Apartado 1.».
6. Memoria de datos
Este dispositivo almacena automáticamente hasta 99 mediciones
por cada usuario.
Ver los valores guardados
Seleccioné usuario 1 o 2 con el interruptor de cambio de usuario
9
.
Presione brevemente el botón M AT cuando el dispositivo esté
apagado. En la pantalla aparecerá «M» BO y «A», cual representa
el promedio de todos los valores almacenados.
Al volver a pulsar el botón M se vuelve a visualizar el valor anterior.
Pulsando el botón M repetidamente se puede cambiar de un valor
guardado a otro.
Memoria llena
Asegúrese de que no exceder la capacidad máxima de 99
memorias de almacenamiento por usuario.
Cuando la
memoria está llena, el valor más antiguo es reemplazado
por el valor número 100.
Los valores deberán ser evaluados
por un médico antes de alcanzar la capacidad máxima de la
memoria - en caso contrario, se perderán los datos.
Borrar todos los valores
Asegúrese que el usuario correcto está activado.
1. Con el dispositivo apagado, seleccione el usuario 1 ó 2 con el
interruptor de cambio de usuario 9.
2. Mantenga pulsado el botón M AT hasta que en la pantalla
aparezca «CL». Deje de pulsar el botón.
3. Mantenga pulsado el botón M mientras «
CL
» esté parpadeando
para borrar permanente todos los valores del usuario seleccio-
nado.
Cancelar el borrado: pulse el botón ON/OFF 1 mientras
«CL» esté parpadeando.
No es posible borrar valores individuales.
7. Indicador de baterías y cambio de baterías
Baterías con poca carga
Cuando las baterías están gastadas aproximadamente ¾, el
símbolo de baterías AM parpadea al momento de encender el
dispositivo (se visualiza una batería parcialmente cargada).
Aunque el dispositivo seguirá midiendo de manera fiable, tenga a
mano baterías de recambio.
Baterías descargadas – cambio
Cuando las baterías están gastadas, el símbolo de baterías AM
parpadea al momento de encender el dispositivo (se visualiza una
batería descargada). Ya no se puede realizar ninguna medición y
es preciso cambiar las baterías.
1. Abra el compartimento de baterías 4 situado en el fondo del
dispositivo.
2. Sustituya las baterías; asegúrese de que la polaridad sea la
correcta, tal como lo indican los signos en el compartimiento.
3. Para ajustar la fecha y la hora, siga el procedimiento descrito
en el «Apartado 2.».
La memoria retiene todos los valores, aunque haya que rese-
tear la fecha y la hora; para este fin, el número del año
parpadea automáticamente después de cambiar las baterías.
¿Qué baterías y qué procedimiento?
Utilice 4 baterías alcalinas nuevas de tamaño AA, de 1,5 V,
de larga duración.
No utilice baterías caducadas.
Si no va a usar el dispositivo durante un período prolon-
gado, extraiga las baterías.
Uso de baterías recargables
Este dispositivo también se puede usar con baterías recargables.
Utilice únicamente baterías reutilizables del tipo «NiMH».
Las baterías se deben extraer y recargar, cuando aparezca
el símbolo de batería (batería descargada). No deben
permanecer en el interior del dispositivo, ya que se pueden
dañar (descarga total como resultado de un uso poco
frecuente del dispositivo, incluso estando apagado).
Retire siempre las baterías recargables si no va a usar el
dispositivo en una semana o más.
¡Las baterías NO se pueden recargar dentro del tensiómetro!
Recargue las baterías en un cargador externo y observe la
información relativa a la recarga, el cuidado y a la duración.
13BP A3 Plus
ES
8. Uso de un adaptador de corriente
Este dispositivo se puede hacer funcionar utilizando el adaptador
de corriente de Microlife (DC 6V, 600mA).
Utilice únicamente el adaptador de corriente de Microlife
disponible como accesorio original, apropiado para su
voltaje de alimentación.
Asegúrese de que no estén dañados ni el adaptador ni el cable.
1. Inserte el cable del adaptador en el enchufe para el adaptador
de corriente 5 situado en el dispositivo.
2. Inserte la clavija del adaptador en una caja de enchufe.
Mientras esté conectado
el ada
ptador de corriente, no se consume
corriente de las baterías.
9. Mensajes de error
Si se produce un error durante la medición, esta se interrumpe y
se visualiza un mensaje de error, p. ej., «ERR 3».
* Por favor, consulte inmediatamente a su médico, si este o cual-
quier otro problema ocurre repetidamente.
Si cree que los resultados son inusuales, por favor, lea
detenidamente la información en el «Apartado 1.».
10. Seguridad, cuidado, control de precisión y eliminación
de residuos
Seguridad y protección
Siga las instrucciones de uso. Este documento proporciona infor-
mación importante de operación y seguridad del producto con
respecto a este dispositivo. Lea atentamente este documento
antes de usar el dispositivo y consérvelo para futuras consultas.
Este dispositivo sólo se debe utilizar para los propósitos
descritos en estas instrucciones. El fabricante no se responsa-
biliza de ningún daño causado por un uso inadecuado.
El dispositivo está integrado por componentes sensibles y se
debe tratar con cuidado. Respete las indicaciones de almace-
namiento y funcionamiento que se describen en el apartado
«Especificaciones técnicas».
Proteja el dispositivo de:
- Agua y humedad.
- Temperaturas extremas.
- Impactos y caídas.
- Contaminación y polvo.
- Luz directa del sol.
- Calor y frío.
Los brazaletes son sensibles y deben tratarse cuidadosamente.
No intercambie ni utilice ningún otro tipo de manguito o
conector del manguito con este dispositivo.
Infle el manguito únicamente cuando está colocado correcta-
mente en el brazo.
No use el dispositivo cerca de fuertes campos eléctricos tales
como teléfonos móviles o equipos de radio. Mantenga el dispo-
Error Descripción Posible causa y solución
«
ERR 1
» Señal dema-
siado débil
Las señales del pulso en el manguito
son demasiado débiles. Vuelva a colocar
el manguito y repita la medición.*
«
ERR 2
»
BN
Señal de
error
Durante la medición se han detectado
señales de error por el manguito,
causadas, por ejemplo, por el movimiento
o la contracción de un músculo. Repita la
medición manteniendo el brazo quieto.
«
ERR 3
»
BK
No hay
presión en
el manguito
No se puede generar una presión
adecuada en el manguito. Se puede
haber producido una fuga. Compruebe
que el manguito esté conectado correc-
tamente y que no esté demasiado
suelto. Cambie las baterías si fuese
necesario. Repita la medición.
«
ERR 5
» Resultado
anormal
Las señales de medición son imprecisas y,
por ello, no se puede visualizar ningún resul-
tado. Lea la lista de chequeo para efectuar
mediciones fiables y repita la medición.*
«
ERR 6
» Modo
MAM
Ha habido demasiados errores durante
la medición en el modo MAM, por lo que
es imposible obtener un resultado final.
Lea la lista de chequeo para efectuar
mediciones fiables y repita la medición.*
«
HI
»
Pulso o
presión de
manguito
demasiado
alto
La presión en el manguito es demasiado
alta (superior a 299 mm Hg) o el pulso es
demasiado alto (más de 200 latidos por
minuto). Relájese durante 5 minutos y
repita la medición.*
«
LO
»Pulso dema-
siado bajo
El pulso es demasiado bajo (menos de 40
latidos por minuto). Repita la medición.*
Error Descripción Posible causa y solución
14
sitivo a una distancia mínima de 3,3 m de estos aparatos
cuando lo utilice.
No utilice el dispositivo si cree que puede estar roto o detecta
alguna anomalía.
Nunca abra el dispositivo.
Si no va a utilizar el dispositivo durante un periodo largo de
tiempo, extraiga las baterías.
Lea las instrucciones de seguridad adicionales en los disposi-
tivos individuales de este manual.
El resultado de medición dado por este dispositivo no es un
diagnóstico. No está reemplazando la necesidad para la
consulta de un médico, especialmente si no coincide con los
síntomas del paciente. No confíe sólo en el resultado de la
medición, considere siempre otros síntomas potencialmente
presentes y la retroalimentación del paciente. Se aconseja
llamar a un médico o una ambulancia si es necesario.
Asegúrese de que los niños no utilicen el dispositivo sin
supervisión, puesto que podrían tragarse algunas de las
piezas más pequeñas. Tenga en cuenta el riesgo de
estrangulamiento en caso de que este dispositivo se sumi-
nistre con cables o tubos.
Cuidado del dispositivo
Limpie el dispositivo únicamente con un paño suave y seco.
Limpieza del brazalete
Para limpiar el manguito hágalo cuidadosamente con un paño
húmedo y jabón neutro.
ATENCIÓN: ¡No lave el brazalete en la lavadora!
Control de precisión
Recomendamos someter este dispositivo a un control de precisión
cada 2 años o después de un impacto mecánico (p. ej., si se ha
caído). Por favor, contacte su servicio al cliente Microlife local para
concertar la revisión (ver introducción).
Eliminación de residuos
Las baterías y los dispositivos electrónicos se deben
eliminar según indique la normativa local pertinente y no se
deben desechar junto con la basura doméstica.
11.Garantía
Este dispositivo tiene una garantía de 5 años a partir de la fecha
de compra. Durante este período de garantía, a nuestra discre-
ción, Microlife reparará o reemplazará el producto defectuoso de
forma gratuita.
La garantía no será válida si abre o manipula el dispositivo.
Los siguientes artículos están excluidos de la garantía:
Costos de transporte y riesgos del transporte.
Daños causados por la aplicación incorrecta o el incumpli-
miento de las instrucciones de uso.
Daño causado por fugas de baterías.
Daño causado por accidente o mal uso.
Material de embalaje / almacenamiento e instrucciones de uso.
Comprobaciones periódicas y mantenimiento (calibración).
Accesorios y piezas de desgaste: Baterías, adaptador de
corriente (opcional).
El brazalete está cubierto por una garantía funcional (estan-
queidad de la vejiga) durante 2 años.
En caso de que se requiera un servicio de garantía, comuníquese
con el distribuidor donde adquirió el producto o con su servicio
local de Microlife. Puede ponerse en contacto con su servicio local
Microlife a través de nuestro sitio web:
www.microlife.com/support
La compensación se limita al valor del producto. La garantía se
otorgará si el producto completo se devuelve con la factura
original. La reparación o el reemplazo dentro de la garantía no
prolonga ni renueva el período de garantía. Los reclamos y dere-
chos legales de los consumidores no están limitados por esta
garantía.
12.Especificaciones técnicas
Condiciones de
funcionamiento:
10 - 40 °C / 50 - 104 °F
15 - 95% de humedad relativa máxima
Condiciones de
almacenamiento:
-20 - +55 °C / -4 - +131 °F
15 - 95% de humedad relativa máxima
Peso: 368 g (incluyendo baterías)
Tamaño: 143 x 85 x 58 mm
Procedimiento de
medición:
oscilométrico, según el método Koro-
tkoff: Fase I sistólica, fase V diastólica
Nivel de medición: 20 - 280 mm Hg – presión arterial
40 - 200 latidos por minuto – pulso
Intervalo de indicación
de la presión del
manguito: 0 - 299 mm Hg
15BP A3 Plus
ES
Este dispositivo esta en conformidad con los requerimientos de la
Directiva 93/42/CEE relativa a productos sanitarios.
Reservado el derecho a realizar modificaciones técnicas.
Resolución: 1 mm Hg
Precisión estática: presión dentro de ± 3 mm Hg
Precisión del pulso: ± 5% del valor medido
Fuente de corriente:
4 baterías alcalinas 1,5 V; tamaño AA
Adaptador de voltaje c.a. 6V,
600 mA (opcional)
Duración de la batería:
aprox.
920
mediciones (usando baterías
nuevas)
Clase IP: IP20
Referencia a los
estándares:
EN 1060-1 /-3 /-4; IEC 60601-1;
IEC 60601-1-2 (EMC); IEC 60601-1-11
Vida útil esperada:
Dispositivo:
5
años o
10.000
mediciones
Accesorios: 2 años
16
Écran
Veuillez lire attentivement les instructions avant d'utiliser ce
produit.
Partie appliquée du type BF
Utilisation:
Ce tensiomètre oscillométrique est conçu pour mesurer la pres-
sion artérielle de manière non invasive chez les personnes âgées
de 12 ans et plus.
Il est validé cliniquement chez les patients souffrant d'hyperten-
sion, d'hypotension, de diabète, de grossesse, de pré-éclampsie,
d'athérosclérose, d'insuffisance rénale terminale, d'obésité ainsi
que pour les personnes âgées.
Cher client,
Cet appareil a été développé en collaboration avec des médecins.
Les tests cliniques dont il a fait l'objet ont montré que les résultats
affichés sont d'une très grande précision.*
Si vous avez des questions, des problèmes ou désirez
commander des pièces détachées, veuillez contacter votre
Service Clients Microlife local. Adressez-vous à votre revendeur
ou à la pharmacie où vous avez acheté l'appareil pour avoir les
coordonnées du représentant Microlife de votre pays. Vous
pouvez aussi visiter notre site Internet à l'adresse
www.microlife.com, où vous trouverez de nombreuses et
précieuses informations sur nos produits.
Restez en bonne santé avec Microlife AG.
* Cet appareil applique la même technologie de mesure que le
modèle primé «BP 3BTO-A» testé conformément aux standards
de la Société Britannique et Irlandaise de l'Hypertension (BIHS).
Microlife BP A3 Plus
FR
1
Bouton ON/OFF (marche/arrêt)
2
Écran
3
Prise pour brassard
4
Compartiment à piles
5
Prise pour adaptateur secteur
6
Brassard
7
Connecteur brassard
8
Sélecteur MAM
9
L'interrupteur de sélectionner l'utilisateur
AT
Bouton M (mémoire)
AK
Bouton de réglage du temps
AL
Indicateur utilisateur
AM
Indicateur d'état de charge des piles
AN
Date/Heure
AO
Tension systolique
AP
Tension diastolique
AQ
Fréquence des battements cardiaques
AR
Indicateur de classification de mesure
AS
Intervalle de temps MAM
BT
Indicateur de pouls
BK
Indicateur de brassard
BL
Mode MAM
BM
(IHB) symbole de rythme cardiaque irrégulier
BN
Indicateur de mouvement de bras
BO
Indicateur de mise en mémoire
A conserver dans un endroit sec
17BP A3 Plus
FR
Sommaire
1. Informations importantes sur la tension et l'auto-mesure
Comment puis-je évaluer ma tension?
2. Première mise en service de l'appareil
Insertion des piles
Réglage de la date et de l'heure
Sélection du brassard correct
Choix de l'utilisateur
Sélection du mode standard ou MAM
Mode MAM (hautement recommandé)
3. Prise de tension
Comment ne pas enregistrer une lecture
4. Apparition du symbole de rythme cardiaque irrégulier
(IHB)
5. Affichage de l'indicateur de classification de mesure
6. Mémoire
Visualisation des valeurs enregistrées
Mémoire saturée
Suppression de toutes les valeurs
7. Indicateur d'état de charge des piles et de
remplacement
Piles presque déchargées
Piles déchargées – remplacement
Types de pile et procédure
Utilisation de piles rechargeables
8. Utilisation d'un adaptateur secteur
9. Messages d'erreurs
10. Sécurité, entretien, test de précision et élimination de
l'équipement
Sécurité et protection
Entretien de l'appareil
Nettoyage du brassard
Test de précision
Élimination de l'équipement
11. Garantie
12. Caractéristiques techniques
Carte de garantie (voir verso)
1. Informations importantes sur la tension et l'auto-
mesure
La tension est la pression du sang qui circule dans les artères
sous l'effet du pompage du coeur. Deux valeurs, la tension
systolique (valeur la plus haute) et la tension diastolique
(valeur la plus basse), sont toujours mesurées.
L'appareil indique aussi le pouls (nombre de battements du
coeur par minute).
Une tension élevée en permanence peut nuire à votre santé
et nécessite un traitement. Veuillez consulter votre médecin.
Signalez toujours la tension relevée à votre médecin et faites-
lui part de toute observation inhabituelle ou de vos doutes. Ne
vous basez jamais sur une seule prise de tension.
De nombreux facteurs peuvent provoquer une tension trop
élevée. Votre médecin pourra vous fournir des explications
plus détaillées à ce sujet et vous prescrire un traitement appro-
prié. Outre les médicaments, exercice et perdre du poids
peuvent également abaisser votre tension artérielle.
En aucun cas vous ne devez modifier vos doses de médica-
ments ou initier un traitement sans consulter votre médecin.
La tension varie fortement au cours de la journée selon les
efforts physiques et l'état. Vous devriez de ce fait toujours
effectuer les mesures dans les mêmes conditions, au
calme, quand vous sentez détendu! Chaque jour, prendre au
moins 2 mesures le matin et 2 mesures le soir puis calculer la
moyenne des résultats obtenus.
Il est courant que deux mesures effectuées l'une à la suite de
l'autre fournissent des résultats très différents. C'est pourquoi
nous recommandons d'utiliser la technologie MAM.
Il n'est pas non plus inhabituel de constater des écarts entre les
mesures prises par le médecin ou à la pharmacie et celles que
vous effectuez à la maison puisque les environnements sont
très différents.
Plusieurs mesures fournissent des informations plus fiables
sur votre tension artérielle qu'une seule mesure. C'est pourquoi
nous recommandons d'utiliser la technologie MAM.
Observez une pause d'au moins 15 secondes entre deux
mesures.
Si vous souffrez d'une arythmie cardiaque, consultez votre
médecin avant d'utiliser l'appareil. Voir également le chapitre
«Apparition du symbole de rythme cardiaque irrégulier (IHB)»
de ce manuel d'utilisation.
18
L’affichage du pouls ne permet pas de contrôler la
fréquence des stimulateurs cardiaques.
Si vous êtes enceinte, vous devriez surveiller régulièrement
votre tension artérielle car elle peut changer drastiquement
durant cette période.
Ce tensiometre a été spécialement testé pour une utilisation
pendant la grossesse et la prééclampsie. Lorsque vous
obtenez des mesures élevées inhabituelles au cours de la
grossesse, il est conseillé de refaire une mesure après un
petit moment (par exemple 1 heure). Si la mesure est encore
trop élevée, consultez votre médecin ou votre gynécologue.
Comment puis-je évaluer ma tension?
La valeur la plus haute est déterminante pour l'évaluation.
Exemple: une tension artérielle valeur 140/80 mmHg ou la valeur
130/90 mmHg indique une «tension trop haute».
2. Première mise en service de l'appareil
Insertion des piles
Après avoir déballé votre appareil, insérez d'abord les piles. Le
compartiment à piles 4 se trouve sur le dessous de l'appareil.
Insérez les piles (4 x 1,5 V, format AA) en respectant les indica-
tions de polarité.
Réglage de la date et de l'heure
1. Après l'insertion de nouvelles piles, les chiffres de l'année
clignotent sur l'écran. Vous pouvez régler l'année en appuyant
sur le bouton M AT. Pour confirmer et régler le mois, pressez le
bouton de réglage du temps AK.
2. Vous pouvez maintenant régler le mois en appuyant sur le
bouton M. Pour confirmer, pressez le bouton de réglage du
temps puis réglez le jour.
3. Veuillez suivre les instructions ci-dessus pour régler le jour,
l'heure et les minutes.
4. Après la définition des minutes et la pression du bouton de
réglage du temps, la date et l'heure réglées s'afficheront.
5. Pour changer la date et l'heure, pressez le bouton de réglage
du temps environ 3 secondes jusqu'à ce que les chiffres de
l'année clignotent. Vous pouvez alors saisir les nouvelles
valeurs comme décrit ci-dessus.
Sélection du brassard correct
Microlife offre différentes tailles de brassard. Sélectionnez la taille
qui correspond à la circonférence du haut du bras (mesurée en
tendant le brassard autour du haut du bras dans la partie centrale).
Des brassards préformés «Easy» sont disponibles en
option pour un meilleur confort et utilisation.
Utilisez exclusivement des brassards Microlife.
Adressez-vous à votre Service Microlife local si le brassard 6
fourni ne convient pas.
Raccordez le brassard à l'appareil en enfichant le connecteur
7
dans la prise
3
aussi loin que possible.
Choix de l'utilisateur
Cet appareil permet l'enregistrement des mesures pour 2 utilisateurs.
Avant chaque mesure, régler l'interrupteur de sélection pour
l'utilisateur 9 recherché 1 ou 2.
Utilisateur 1: réglez l'interrupteur 9 vers le haut l'icône 1.
Utilisateur 2: réglez l'interrupteur 9 vers le bas l'icône 2.
La première personne à utiliser l'appareil devrait choisir
utilisateur 1.
Tableau de classification des tensions arterielles chez les adultes,
conformément aux directives internationales (ESH, ESC, JSH).
Données en mmHg.
Plage
Systo-
lique
Diasto-
lique
Recommanda-
tion
1. Tension normale < 120 < 74 Contrôle
personnel
2. Tension optimale 120 - 129 74 - 79 Contrôle
personnel
3. Tension élevée 130 - 134 80 - 84 Contrôle
personnel
4. Tension trop haute 135 - 159 85 - 99 Consultation
médicale
5. Tension dangereu-
sement haute
160 100 Consultation
médicale immé-
diate!
Taille du brassard pour la circonférence du haut du bras
S 17 - 22 cm
M 22 - 32 cm
M - L 22 - 42 cm
L 32 - 42 cm
L - XL 32 - 52 cm
19BP A3 Plus
FR
Sélection du mode standard ou MAM
Cet appareil vous permet de choisir le mode standard (mesure
standard simple) ou le mode MAM (mesure triple automatique).
Pour choisir le mode standard, poussez le sélecteur MAM 8 sur
le côté de l'appareil vers le bas, en position «1». Pour activer le
mode MAM, poussez ce sélecteur vers le haut, en position «3».
Mode MAM (hautement recommandé)
En mode
MAM
, 3 mesures sont réalisées l'une à la suite de l'autre
et le résultat est analysé par l'appareil puis affiché. Comme la
tension varie sans cesse, un résultat déterminé de cette façon est
plus fiable qu'un résultat obtenu avec une mesure simple.
Quand vous sélectionnez le mode 3 mesures, le symbole MAM
BL
apparaît à l'écran.
La partie droite inférieure de l'écran signale le numéro des 3
mesures réalisées au moyen des chiffres 1, 2 et 3.
Il y a une pause de 15 secondes entre les mesures. Un compte
à rebours indique le temps restant.
Les résultats individuels ne s'affichent pas. Votre tension
n'apparaîtra sur l'écran qu'après la réalisation des 3 mesures.
N'enlevez pas le brassard entre les mesures.
Si l'appareil juge l'une des mesures de la série non plausible, il
en effectuera une quatrième.
3. Prise de tension
Pré-requis pour une mesure fiable
1. Évitez d'effectuer des efforts physiques, de manger ou de
fumer directement avant la prise de tension.
2. Asseyez-vous sur une chaise à dossier et détendez-vous
pendant 5 minutes. Gardez les pieds à plat sur le sol et ne
croisez pas les jambes.
3. Prenez toujours la tension sur le même bras (normalement
à gauche). Il est recommandé que les médecins prennent, lors
de la première visite, des mesures aux deux bras afin de définir
le bras de référence. Le bras avec la plus haute tension arté-
rielle doit être mesuré.
4. Enlevez les vêtements serrés du haut du bras. Pour éviter une
constriction, n'enroulez pas les manches en les remontant - elles
n'interfèrent pas avec le brassard quand elles restent à plat.
5. Assurez vous toujours que la taille du brassard correspond bien
à la circonférence du bras (en impression sur le brassard).
Placez puis fermez le brassard sans trop le serrer.
Vérifiez que le brassard est positionné 1-2 cm au dessus de
la pliure du coude.
L’artère représentée sur le brassard (barre d’environ 3 cm)
doit être centrée exactement sur l’artère qui parcourt la
partie interne du bras.
Placez votre bras sur un support pour qu'il soit détendu.
Vérifiez que le brassard est au même niveau que votre cœur.
6. Pressez le bouton ON/OFF 1 pour démarrer la mesure.
7. Le brassard commence à se gonfler. Essayez d'être détendu.
Ne bougez pas et ne faites pas travailler les muscles de votre
bras avant l'affichage du résultat. Respirez normalement et
évitez de parler.
8. Une fois que le brassard a atteint la pression correcte, le
gonflage s'arrête et la pression diminue progressivement. Si la
bonne pression n'est pas atteinte, l'appareil pompera plus d'air
dans le brassard.
9. Pendant la mesure, l'indicateur de pouls BT clignote sur l'écran.
10.Le résultat, formé de la tension systolique
AO
, de la tension dias-
tolique
AP
et du pouls,
AQ
s'affiche. Reportez-vous aussi aux
explications données sur d'autres affichages dans ce manuel.
11.Une fois la mesure prise, enlevez le brassard.
12.Mettez l'appareil hors tension. (Le tensiomètre se met hors
tension tout seul au bout de 1 min. environ).
Comment ne pas enregistrer une lecture
Aussitôt que le résultat apparaît à l’écran, appuyer et maintenir le
bouton ON/OFF 1 jusqu’à ce que «M» BO clignote. Confirmer
pour supprimer la mesure en appuyant sur le bouton M AT.
Vous pouvez arrêter la mesure à tout moment en pressant
le bouton ON/OFF (par ex. si vous n'êtes pas à l'aise ou
sentez une pression désagréable).
Si vous savez que votre tension artérielle systolique
est très élevée, il peut être préférable pour vous de définir
la tension individuellement. Pressez le bouton ON/OFF
après avoir gonflé le tensiomètre à environ 30 mmHg
(montré sur l'écran). Maintenez le bouton enfoncé jusqu'à
ce que la tension dépasse d'environ 40 mmHg la valeur
systolique attendue. Relâchez alors le bouton.
4. Apparition du symbole de rythme cardiaque irrégu-
lier (IHB)
Ce symbole BM indique qu'un rythme cardiaque irrégulier a été
détecté. Dans ce cas, la pression artérielle mesurée peut s'écarter
20
de vos valeurs réelles de tension artérielle. Il est recommandé de
refaire une mesure de tension.
5. Affichage de l'indicateur de classification de mesure
Les rectangles situés sur le bord gauche de l'écran
AR
vous indiquent
dans quelle fourchette votre résultat se trouve. Selon la hauteur du
rectangle, la valeur d'affichage est soit à l'intérieur de l'optimum
(vert), élevée (jaune), trop haute (orange) ou dangereusement haute
gamme (rouge). Cette classification correspond à
4
plages définies
par les directives internationales (
ESH, ESC, JSH
), comme décrit
dans la «section 1.».
6. Mémoire
L'appareil enregistre automatiquement jusqu'à 99 mesures pour
chacun des 2 utilisateurs.
Visualisation des valeurs enregistrées
Sélectionner l'utilisateur 1 ou 2 avec l'interrupteur 9.
Pressez le bouton M
AT
brièvement quand l’appareil est hors tension.
L'écran affiche d'abord «
M
»
BO
et «
A
», qui représente la moyenne
de toutes les mesures mémorisées.
Une nouvelle pression du bouton M réaffiche la valeur précédente.
Une pression répétée du bouton M vous permet de naviguer entre
les valeurs enregistrées.
Mémoire saturée
Veuillez noter que la capacité d'enregistrement est de 99
mémoires par utilisateur et ne peut aller au delà. Une fois
que la mémoire est pleine, le résultat le plus ancien
sera remplacé par la nouvelle (100) mesure. Les valeurs
doivent être évaluées par un médecin avant que la capacité
maximale de mémoire ne soit atteinte – sinon les données
seront perdues.
Suppression de toutes les valeurs
Vérifier que le bon utilisateur a été bien sélectionné.
1. Sélectionner l'utilisateur 1 ou 2 avec l'interrupteur de sélec-
tionner l'utilisateur 9, lorsque l'appareil est éteint.
2. Maintenez appuyer le bouton M AT jusqu'à ce que «CL»
clignote à l'écran, puis relâchez le bouton M.
3. Appuyez sur le bouton M pendant que «
CL
» clignote pour effacer
définitivement toutes les valeurs de l'utilisateur sélectionné.
Annuler suppression: appuyez sur le bouton ON/OFF 1
pendant que «CL» clignote.
Il est impossible d'effacer des valeurs individuelles.
7. Indicateur d'état de charge des piles et de
remplacement
Piles presque déchargées
Quand les piles sont usées aux ¾ environ, le symbole
AM
clignotera
dès la mise sous tension de l'appareil (affichage d'une pile à moitié
remplie). Bien que l'appareil continue à effectuer des mesures
fiables, vous devriez remplacer les piles le plus tôt possible.
Piles déchargées – remplacement
Quand les piles sont déchargées, le symbole AM clignotera dès la
mise sous tension de l'appareil (affichage d'une pile déchargée). Il
vous est impossible de prendre d'autres mesures et vous devez
remplacer les piles.
1. Ouvrez le compartiment à piles 4 sur le dessous de l'appareil.
2. Remplacez les piles – assurez-vous de la bonne polarité en
vous basant sur les symboles placés dans le logement.
3. Pour régler la date et l'heure, suivez la procédure décrite à la
«section 2.».
La mémoire conserve les valeurs enregistrées mais la date et
l'heure doivent être redéfinies – les chiffres de l'année
clignotent automatiquement après le remplacement des piles.
Types de pile et procédure
Utiliser 4 nouvelles piles alcalines de 1,5 V, longue durée,
format AA.
N'utilisez pas les piles au-delà de leur date de péremption.
Si vous ne comptez pas utiliser l'appareil pendant une
période prolongée, prenez soin de retirer les piles.
Utilisation de piles rechargeables
Vous pouvez aussi faire fonctionner cet appareil avec des piles
rechargeables.
Veillez à n'utiliser que des piles rechargeables du type «NiMH».
Veillez à retirer et à recharger les piles quand le symbole
d'usure (pile déchargée) apparaît. Ne laissez pas les piles
à l'intérieur de l'appareil. Elles pourraient s'endommager
(décharge totale par inactivité prolongée de l'appareil,
même s'il est hors tension).
Information destinée au médecin en cas d'apparition régu-
lière du symbole IHB sur l'écran.
Cet appareil mesure la pression artérielle selon une méthode
oscillométrique. Pendant la mesure de la pression artérielle, il
analyse également le pouls et indique si la fréquence cardiaque
est irrégulière.
21BP A3 Plus
FR
Retirez toujours les piles rechargeables si vous n'avez pas
l'intention d'utiliser l'appareil pendant une semaine ou plus.
Il est IMPOSSIBLE de charger les piles quand elles sont à
l'intérieur du tensiomètre. Rechargez ces piles dans un
chargeur externe et observez les instructions relatives à la
charge, à l'entretien et à la durée de vie.
8. Utilisation d'un adaptateur secteur
Vous pouvez faire marcher cet appareil à l'aide d'un adaptateur
secteur Microlife (DC 6V, 600 mA).
Utilisez seulement l'adaptateur Microlife disponible comme
accessoire original pour l'alimentation électrique.
Veillez à ce que ni l'adaptateur secteur ni le câble ne soient
endommagés.
1. Enfichez le câble d'alimentation dans la prise pour l'adaptateur
secteur 5 sur le tensiomètre.
2. Branchez le connecteur de l'adaptateur secteur sur la prise de
courant murale.
Quand l'adaptateur secteur est raccordé, les piles ne sont pas sollicitées.
9. Messages d'erreurs
Si une erreur se produit durant la mesure, celle-ci est interrompue
et un message d'erreur, par ex. «ERR 3», s'affiche.
* Veuillez consulter immédiatement votre médecin si cela ou tout
autre problème se produit à plusieurs reprises.
Si vous obtenez des résultats que vous jugez inhabituels,
veuillez lire attentivement les indications de la «section 1.».
10.Sécurité, entretien, test de précision et élimination
de l'équipement
Sécurité et protection
Respectez les instructions d’utilisation. Ce document fournit des
informations importantes sur le fonctionnement et la sécurité de cet
appareil. Veuillez lire attentivement ce document avant d'utiliser
l'appareil et conservez-le pour vous y référer ultérieurement.
Cet appareil est réservé aux applications décrites dans ce
manuel. Le fabricant ne peut être tenu pour responsable de
dommages provoqués par une utilisation incorrecte.
Cet appareil comprend des éléments sensibles et doit être traité
avec précaution. Respectez les conditions de stockage et
d'emploi indiquées à la section «Caractéristiques techniques».
Il convient de le protéger contre:
- l'eau et l'humidité
- les températures extrêmes
- les chocs et chutes
- les saletés et la poussière
- les rayons solaires directs
- la chaleur et le froid
Les brassards sont des éléments sensibles qui requièrent des
précautions.
Ne pas utiliser un brassard ou connecteur autre que celui fourni
par Microlife.
Ne gonflez le brassard qu'après l'avoir ajusté autour du bras.
Erreur Description Cause(s) possible(s) et solution
«ERR 1» Signal trop
faible
Les signaux de pulsation sur le brassard
sont trop faibles. Repositionnez le bras-
sard et répétez la mesure.*
«ERR 2»
BN
Signal
incorrect
Pendant la mesure, des signaux incor-
rects ont été détectés par le brassard
suite à des mouvements du bras ou à un
effort musculaire. Répétez la mesure
sans bouger votre bras.
«ERR 3»
BK
Pas de
pression
dans le
brassard
Le brassard ne se gonfle pas à la pression
requise. Des fuites peuvent s'être produites.
Vérifiez si le brassard est bien raccordé et
suffisamment serré. Remplacez les piles si
nécessaire. Répétez la mesure.
«ERR 5» Résultat
anormal
Les signaux de mesure sont inexacts et
aucun résultat de mesure ne s'affiche de ce
fait. Lisez la liste de contrôle pour l'exécution
de mesures fiables, puis répétez la mesure.*
«ERR 6» Mode MAM Trop d'erreurs pendant la mesure en
mode MAM, ce qui empêche l'obtention
d'un résultat final. Lisez la liste de
contrôle pour l'exécution de mesures
fiables, puis répétez la mesure.*
«HI» Pouls ou
pression de
brassard
trop élevé
La pression du brassard est trop élevée
(plus de 299 mmHg) OU le pouls est trop
haut (plus de 200 battements par
minute). Reposez-vous 5 minutes, puis
répétez la mesure.*
«LO» Pouls trop
bas
Le pouls est trop bas (moins de 40 batte-
ments par minute). Répétez la mesure.*
Erreur Description Cause(s) possible(s) et solution
22
Ne mettez pas l'appareil en service dans un champ électromagné-
tique de grande intensité, par exemple à proximité de téléphones
portables ou d'installations radio. Garder une distance minimale
de 3,3 mètres de ces appareils lors de toute utilisation.
N'utilisez pas l'appareil si vous pensez qu'il est endommagé ou
remarquez quelque chose de particulier.
N'ouvrez jamais l'appareil.
Si vous comptez ne pas utiliser l'appareil pendant une période
prolongée, prenez soin de retirer les piles.
Lisez attentivement les indications de sécurité mentionnées
dans les différentes sections de ce mode d'emploi.
La mesure délivrée par cet appareil ne constitue pas un
diagnostic. Il ne remplace pas la nécessité d'une consultation
médicale, surtout si elle ne correspond pas aux symptômes du
patient. Ne comptez pas uniquement sur le résultat de la
mesure, considérez toujours d'autres symptômes pouvant
survenir et le ressenti du patient. Il est conseillé d'appeler un
médecin ou une ambulance si nécessaire.
Ne laissez jamais les enfants utiliser l'appareil sans surveil-
lance. Certaines de ses parties sont si petites qu'elles
peuvent être avalées. Possible risque d’étranglement dans le
cas où l’appareil est fourni avec des câbles ou des tuyaux.
Entretien de l'appareil
Utilisez exclusivement un chiffon sec et doux pour nettoyer l'appareil.
Nettoyage du brassard
Nettoyer le brassard avec précaution à l'aide d'un chiffon humide
et de l'eau savonneuse.
AVERTISSEMENT: Ne pas laver le brassard en machine
ou au lave vaisselle!
Test de précision
Nous recommandons de faire contrôler la précision de cet appareil
tous les 2 ans ou après un choc mécanique (par ex. chute).
Veuillez-vous adresser à votre Service Microlife local pour
convenir d'une date (voir avant-propos).
Élimination de l'équipement
Les piles et appareils électroniques doivent être éliminés en
conformité avec les prescriptions locales, séparément des
ordures ménagères.
11.Garantie
Cet appareil est couvert par une garantie de 5 ans à compter de
la date d'achat. Pendant cette période de garantie, à notre discré-
tion, Microlife réparera ou remplacera sans frais le produit défec-
tueux.
Le fait d'ouvrir ou de modifier l'appareil invalide la garantie.
Sont exclus de la garantie, les cas suivants:
Frais de transport et risques de transport.
Dommages causés par une utilisation incorrecte ou le non-
respect du mode d'emploi.
Dommages causés par une fuite des piles.
Dommages causés par un accident ou une mauvaise utilisa-
tion.
Matériel d'emballage / stockage et mode d'emploi.
Contrôles et maintenance réguliers (étalonnage).
Accessoires et pièces d'usure: Piles, adaptateur secteur (en
option).
Le brassard est couvert par une garantie de fonctionnement de 2
ans.
Pour toute demande de garantie, veuillez contacter le revendeur
auprès duquel le produit a été acheté ou le bureau local Microlife.
Vous pouvez également nous joindre via notre site Internet:
www.microlife.com/support
L'indemnisation est limitée à la valeur du produit. La garantie peut
être accordée que si le produit est retourné complet avec la facture
d'origine. La réparation ou le remplacement sous garantie ne
prolonge ni ne renouvelle la période de garantie. Les prétentions
légales et droits des consommateurs ne sont pas limités par cette
garantie.
23BP A3 Plus
FR
12.Caractéristiques techniques
Cet appareil est conforme aux exigences de la directive relative
aux appareils médicaux 93/42/EEC.
Sous réserve de modifications techniques.
Conditions
d’utilisation:
10 - 40 °C / 50 - 104 °F
Humidité relative 30 - 85 % max.
Conditions de
stockage:
-20 - +55 °C / -4 - +131 °F
Humidité relative 30 - 85 % max.
Poids: 368 g (piles incluses)
Dimensions: 143 x 85 x 58 mm
Procédure de mesure: Oscillométrique, conforme à la méthode
Korotkoff: phase I systolique, phase V
diastolique
Plage de mesure: 20 - 280 mmHg – tension
40 - 200 battements par minute – pouls
Plage de pression
affichée du brassard: 0 - 299 mmHg
Résolution: 1 mmHg
Précision statique: Plage d'incertitude ± 3 mmHg
Précision du pouls: ± 5 % de la valeur lue
Alimentation
électrique:
4 x piles alcalines de 1,5 V; format AA
Adaptateur secteur DC-AC 6 V 600 mA
(en option)
Durée de vie des piles:
env.
920
mesures (avec des piles neuves)
Classe IP: IP20
Référence aux
normes:
EN 1060-1 /-3 /-4; IEC 60601-1;
IEC 60601-1-2 (EMC); IEC 60601-1-11
Espérance de
fonctionnement:
Appareil: 5 ans ou 10’000 mesures
Accessoires: 2 ans
24
Display
Leggere attentamente le istruzioni prima di usare questo
dispositivo.
Parte applicata tipo BF
Destinazione d’uso
Questo misuratore di pressione oscillometrico è destinato alla
misurazione non invasiva della pressione arteriosa nelle persone
oltre i 12 anni di età.
È clinicamente validato per pazienti con ipertensione, ipotensione,
diabete, arteriosclerosi, insufficienza renale allo stadio terminale,
pre-eclampsia, in gravidanza, per gli obesi e gli anziani.
Gentile cliente,
questo dispositivo è stato sviluppato in collaborazione con i medici
e test clinici hanno provato che la precisione della misurazione
della pressione è molto elevata.*
In caso di domande, problemi o per ordinare parti di ricambio,
contattare il proprio rivenditore di fiducia o il locale servizio clienti
di Microlife. In alternativa è possibile visitare il sito www.microlife.it
che offre moltissime informazioni utili sui nostri prodotti.
Rimanete in salute – Microlife AG!
* Questo dispositivo usa la stessa tecnologia di misurazione del
modello «BP 3BTO-A», premiato per la sua precisione e testato in
base al protocollo della British and Irish Hypertension Society
(BIHS).
Microlife BP A3 Plus
IT
1
Tasto ON/OFF
2
Display
3
Presa bracciale
4
Vano batterie
5
Foro di alimentazione per il trasformatore
6
Bracciale
7
Raccordo bracciale
8
Selettore MAM
9
Selettore utente (user)
AT
Tasto M (memoria)
AK
Tasto ora
AL
Indicatore utente
AM
Livello di carica delle batterie
AN
Data/ora
AO
Pressione sistolica (massima)
AP
Pressione diastolica (minima)
AQ
Frequenza cardiaca
AR
Classificatore della pressione arteriosa
AS
Intervallo di tempo MAM
BT
Indicatore di pulsazioni
BK
Indicatore di funzionamento del bracciale
BL
Modalità MAM
BM
Simbolo di Battito Irregolare (IHB)
BN
Indicatore di movimento del braccio
BO
Misurazioni memorizzate
Conservare in luogo asciutto
25BP A3 Plus
IT
Indice
1. Informazioni importanti sulla pressione arteriosa e
l'automisurazione
Come valutare la propria pressione arteriosa
2. Utilizzo del dispositivo per la prima volta
Inserimento delle batterie
Impostazione data e ora
Selezione del bracciale adatto
Selezione dell'utente
Selezionare la modalità standard o MAM
Modalità MAM (altamente raccomandata)
3. Misurazione della pressione arteriosa
Come non memorizzare una misurazione
4. Comparsa del simbolo di Battito Irregolare (IHB)
5. Classificatore della pressione arteriosa
6. Memoria dati
Visualizzare i valori memorizzati
Memoria piena
Cancellare tutti i valori
7. Indicatore e sostituzione batteria
Batterie quasi esaurite
Batterie esaurite – sostituzione
Quali batterie e quale procedura?
Uso di batterie ricaricabili
8. Utilizzo del trasformatore
9. Messaggi di errore
10. Sicurezza, cura, test di precisione e smaltimento
Sicurezza e protezione
Cura del dispositivo
Pulizia del bracciale
Test di precisione
•Smaltimento
11. Garanzia
12. Specifiche tecniche
Tagliando di garanzia (retro di copertina)
1. Informazioni importanti sulla pressione arteriosa e
l'automisurazione
La pressione arteriosa è la pressione del sangue che fluisce
nelle arterie generata dal pompaggio del cuore. Si misurano
sempre due valori, quello sistolico (massima) e quello diasto-
lico (minima).
Il dispositivo indica anche la frequenza cardiaca (il numero di
battiti del cuore in un minuto).
Valori pressori costantemente alti possono danneggiare la
salute e dovono essere curati dal proprio medico!
E' utile mostrare sempre al medico i valori misurati e informarlo
di eventuali anomalie osservate o riscontrate. Non fare mai
affidamento su un'unica misurazione della pressione.
Esistono molte cause di valori della
pressione eccessivamente
alti
. Il medico può fornire ulteriori informazioni o prescrivere un
trattamento se necessario. Oltre al trattamento farmacologico, la
perdita di peso e l'esercizio fisico possono contribuire all'abbas-
samento della pressione.
Per nessun motivo, modificare il dosaggio dei farmaci
prescritti dal medico o iniziare un trattamento senza averlo
consultato.
In base all'attività e alle condizioni fisiche, la pressione arteriosa
è soggetta a fluttuazioni nel corso della giornata.
Pertanto, la
misurazione deve avvenire in condizioni di calma e di rilas-
samento!
Effettuare ogni volta almeno due misurazioni succes-
sive (la mattina e la sera) e fare la media delle misurazioni.
E' assolutamente normale che due misurazioni a distanza ravvi-
cinata possano dare
risultati molto diversi
. Per questo motivo
raccomandiamo di misurare la pressione con la tecnologia MAM.
Differenze fra le misurazioni eseguite dal medico o in farmacia
e quelle effettuate a casa sono normali, in quanto le situazioni
sono completamente diverse.
Misurazioni ripetute forniscono informazioni molto più affida-
bili sulla pressione arteriosa che un'unica misurazione. Per
questo motivo raccomandiamo di misurare la pressione con la
tecnologia MAM.
Fra una misurazione e l'altra far passare un intervallo di
almeno 15 secondi.
Se si soffre di aritmia cardiaca, consultare il proprio medico
prima di utilizzare il dispositivo e leggere anche il capitolo
«Comparsa del simbolo di Battito Irregolare (IHB)» di questo
manuale d’uso.
26
L'indicatore di pulsazioni non è adatto per registrare la
frequenza dei pacemaker!
In gravidanza, la pressione deve essere monitorata regolar-
mente in quanto possono manifestarsi cambiamenti drastici.
Questo dispositivo è studiato specificatamente per l'uso in
gravidanza e pre-eclampsia. Se vengono rilevati valori della
pressione insolitamente elevati in gravidanza, si consiglia di
ripetere nuovamente la misurazione dopo circa un'ora. Se i
valori sono ancora troppo elevati si consiglia di consultare il
proprio medico o il ginecologo.
Come valutare la propria pressione arteriosa
Il valore più elevato è quello che determina la valutazione. Esempio:
un valore di
140/80
mmHg o un valore di pressione arteriosa di
130/
90
mmHg indica «una pressione arteriosa troppo alta».
2. Utilizzo del dispositivo per la prima volta
Inserimento delle batterie
Dopo aver estratto il dispositivo dall’imballaggio inserire le batterie.
Il vano batterie 4 si trova sul fondo del dispositivo. Inserire le
batterie (4 x 1,5 V, tipo AA) osservando la polarità indicata.
Impostazione data e ora
1. Dopo aver inserito le nuove batterie il numero dell'anno
lampeggerà sul display. E' possibile impostare l'anno
premendo il tasto M AT. Per confermare e impostare il mese,
premere il tasto dell'ora AK.
2. E' ora possibile impostare il mese usando il tasto M. Per confer-
mare premere il tasto dell'ora e poi impostare il giorno.
3. Seguire le istruzioni precedenti per impostare giorno, ora e
minuti.
4. Dopo aver impostato i minuti e premuto il tasto dell'ora, la data
e l'ora saranno impostate e l'ora verrà visualizzata.
5. Per modificare la data e l'ora, premere e tenere premuto il tasto
dell'ora per ca. 3 secondi fino a che il numero dell'anno inizierà
a lampeggiare. Ora è possibile immettere i nuovi valori come
precedentemente descritto.
Selezione del bracciale adatto
Microlife offre diverse misure di bracciale. Selezionare la misura
del bracciale che corrisponde alla circonferenza del braccio (misu-
rata mediante applicazione al centro del braccio).
E' possibile utilizzare anche i bracciali preformati «Easy»,
facili da indossare e confortevoli.
Usare esclusivamente bracciali Microlife!
Contattare il rivenditore Microlife di zona se le misure dei brac-
ciali in dotazione 6 non sono adatte per acquistarne uno
nuovo.
Collegare il bracciale al dispositivo inserendo il raccordo del
bracciale 7 nella presa del bracciale 3 il più profondamente
possibile.
Selezione dell'utente
Questo dispositivo permette di memorizzare separatamente le
misurazioni di 2 utenti.
Prima di ogni misurazione, posizionare il selettore utente 9
in base all'utilizzatore: utente 1 o utente 2.
Utente 1: far scorrere in avanti il selettore 9 verso l'icona
dell'utente 1.
Utente 2: far scorrere indietro il selettore 9 verso l'icona
dell'utente 2.
La prima persona che effettua una misurazione dovrebbe
selezionare l'utente 1.
Tabella per la classificazione dei valori della pressione arteriosa
negli adulti in conformità con le linee guida internazionali (ESH,
ESC, JSH). Dati in mmHg.
Ambito Sistolica
Diasto-
lica
Raccomanda-
zioni
1.
pressione arte-
riosa normale
< 120 < 74 autocontrollo
2. pressione arteriosa
ottimale
120 - 129 74 - 79 autocontrollo
3. pressione arteriosa
alta
130 - 134 80 - 84 autocontrollo
4. pressione arteriosa
troppo alta
135 - 159 85 - 99 consultare il
medico
5.
pressione arteriosa
pericolosamente alta
160 100
consultare il medico
con urgenza!
Misura del bracciale per circonferenza del braccio
S 17 - 22 cm
M 22 - 32 cm
M - L 22 - 42 cm
L 32 - 42 cm
L - XL 32 - 52 cm
27BP A3 Plus
IT
Selezionare la modalità standard o MAM
Questo dispositivo consente di selezionare la modalità standard
(misurazione standard singola) o la modalità MAM (3 misurazioni
automatiche). Per selezionare la modalità standard, far scorrere il
tasto MAM 8 in avanti nella posizione «1» e per selezionare la
modalità MAM far scorrere il tasto indietro in posizione «3».
Modalità MAM (altamente raccomandata)
In modalità MAM, vengono eseguite automaticamente 3 misu-
razioni consecutive e i risultati verranno analizzati e visualizzati
automaticamente. La pressione arteriosa fluttua costante-
mente, pertanto un risultato determinato in questo modo è più
affidabile che quello di una singola misurazione.
Quando viene selezionata la modalità delle 3 misurazioni, il
simbolo MAM BL appare sul display.
La sezione in basso a destra del display visualizza 1, 2 o 3 per
indicare quale delle 3 misurazioni è in corso.
C'è una pausa di 15 secondi tra una misurazione e l'altra. Un
conto alla rovescia indica il tempo rimanente.
I risultati individuali non vengono visualizzati. La pressione arte-
riosa sarà visualizzata solo dopo l'esecuzione di tutte e tre le
misurazioni.
Fra una misurazione e l'altra non togliere il bracciale.
Se una delle misurazioni individuali è dubbia, ne verrà eseguita
automaticamente una quarta.
3. Misurazione della pressione arteriosa
Punti da osservare per eseguire una misurazione affidabile
1. Immediatamente prima della misurazione evitare di fare attività
fisica, mangiare o fumare.
2. Stare seduti su una sedia con schienale e rilassarsi per 5 minuti
prima della misurazione. Mantenere i piedi ben appoggiati a
terra e non accavallare le gambe.
3. Effettuare la misurazione sempre sullo stesso braccio (in
genere il sinistro). E' consigliabile che il medico effettui alla
prima visita una doppia misurazione a entrambe le braccia per
determinare dove misurare la pressione successivamente.
Effettuare le misurazioni nel braccio con la pressione più alta.
4. Togliere gli abiti che stringono il braccio. Per evitare costrizioni,
non arrotolare le maniche della camicia - non interferiscono con
il bracciale se questo viene indossato sopra.
5. Assicurarsi sempre che venga utilizzato il bracciale della
dimensione corretta (come riportato sul bracciale).
Stringere il bracciale, ma non troppo.
Assicurarsi che il bracciale sia posizionato 1-2 cm sopra il
gomito.
L’indicatore dell'arteria riportato sul bracciale (barra colo-
rata di ca. 3 cm di lunghezza) deve essere posizionato sopra
l'arteria che corre lungo il lato interno del braccio.
Sostenere il braccio in modo che sia rilassato.
Verificare che il bracciale si trovi più o meno all' altezza del
cuore.
6. Premere il tasto ON/OFF 1 per iniziare la misurazione.
7. Il bracciale si gonfierà automaticamente. Stare in posizione
rilassata, non muoversi e rilassare i muscoli del braccio fino a
che verranno visualizzati i risultati della misurazione. Respirare
normalmente e non parlare.
8. Quando è stata raggiunta la corretta pressione di gonfiaggio,
l'apparecchio si ferma e la pressione scende gradualmente. Se
la pressione necessaria non è stata raggiunta, il dispositivo
gonfierà automaticamente il bracciale di quanto necessario.
9. Durante la misurazione, l'indicatore delle pulsazioni BT
lampeggia sul display.
10.Al termine della misurazione vengono visualizzati i valori della
pressione sistolica AO, della pressione diastolica AP e della
frequenza cardiaca AQ. Consultare le spiegazioni delle altre
visualizzazioni in questo manuale.
11.Al termine della misurazione togliere il bracciale.
12.Spegnere il dispositivo. Il display si spegne automaticamente
dopo ca. 1 min.
Come non memorizzare una misurazione
Quando la misurazione è visualizzata sul display tenere premuto il tasto
ON/OFF
1
fino a quando lampeggerà il simbolo «
M
»
BO
. Confermare
la cancellazione della misurazione premendo il tasto M
AT
.
E' possibile interrompere la misurazione in qualsiasi
momento premendo il tasto ON/OFF (es. in caso di fastidio
o di sensazione di pressione fastidiosa).
In presenza di pressione sistolica alta
(ad es. sopra i 135
mmHg) è opportuno impostare la pressione individualmente.
Premere il tasto ON/OFF dopo che il misuratore ha superato il
valore sistolico stimato di 30 mmHg (visualizzato sul display).
Mantenere premuto il tasto fino a che la pressione supererà di
40 mmHg il valore sistolico stimato, quindi rilasciarlo.
28
4. Comparsa del simbolo di Battito Irregolare (IHB)
Questo simbolo BM indica che è stato rilevato un battito irregolare.
In questo caso, i valori della pressione misurata potrebbero disco-
starsi da quelli abituali. Si consiglia di ripetere la misurazione.
5. Classificatore della pressione arteriosa
Le barre a sinistra nel display AR indicano l'intervallo entro il quale
si trova il valore di pressione arteriosa misurato. A seconda
dell'altezza e del colore raggiunto dal classificatore la valutazione
sarà ottimale (verde), elevata (giallo), alta (arancione) e pericolo-
samente alta (rosso). La classificazione corrisponde ai 4 livelli
previsti dalle linee guida internazionali (ESH, ESC, JSH) come
descritto nella «Sezione 1.».
6. Memoria dati
Questo dispositivo memorizza
99
misurazioni per ognuno dei 2 utenti.
Visualizzare i valori memorizzati
Selezionare l'utente 1 o 2 con il selettore utente 9.
Premere brevemente il tasto M AT, quando il dispositivo è spento.
Sul display apparirà prima la «M» BO con la «A», che indica la
media di tutti i valori memorizzati.
Premendo ancora il tasto M, viene visualizzato il valore prece-
dente. La pressione ripetuta del tasto M consente di passare da un
valore memorizzato ad un altro.
Memoria piena
Fare attenzione a non superare la capacità massima di
memorizzazione che è di 99 misurazioni per utente.
Quando
le 99 memorie sono piene, la misurazione più vecchia
verrà sovrascritta dalla 100esima misurazione.
Le misura-
zioni memorizzate dovrebbero essere valutate dal proprio
medico prima di raggiungere la capacità di memorizzazione
massima – contrariamente i dati andranno persi.
Cancellare tutti i valori
Assicurarsi che sia selezionato l'utente corretto.
1. Selezionare l'utente 1 o 2 con il selettore utente 9, quando il
dispositivo è spento.
2. Tenere premuto il tasto M AT fino a quando il simbolo «CL»
verrà visualizzato e rilasciare il tasto.
3. Quando il simbolo «CL» lampeggerà premere nuovamente il
tasto M per cancellare definitivamente tutte le misurazioni
dell'utente selezionato.
Annullamento della cancellazione: premere il tasto ON/
OFF 1 quando il simbolo «CL» lampeggia.
Non è possibile cancellare singole misurazioni.
7. Indicatore e sostituzione batteria
Batterie quasi esaurite
Quando le batterie sono esaurite di circa ¾, lampeggerà il simbolo
della batteria
AM
appena si accenderà il dispositivo (visualizzazione
batteria parzialmente carica). Anche se il dispositivo effettuerà le
misurazioni in modo affidabile è necessario sostituire le batterie.
Batterie esaurite – sostituzione
Quando le batterie sono esaurite, lampeggerà il simbolo
AM
non
appena si accenderà il dispositivo (visualizzazione batteria esaurita).
Non devono essere eseguite ulteriori misurazioni e le batterie
devono essere sostituite.
1. Aprire il vano batterie 4 sul fondo del dispositivo.
2. Sostituire le batterie verificando che la polarità sia quella indicata
dai simboli nel vano batterie.
3. Impostare data e ora seguendo la procedura descritta nel
«capitolo 2.».
Le misurazioni memorizzate verranno mantenute in
memoria mentre data e ora verranno cancellate – i
segmenti del display relativi a data e ora lampeggeranno.
Quali batterie e quale procedura?
Usare 4 batterie alcaline AA da 1,5 V nuove, a lunga durata.
Non usare le batterie dopo la data di scadenza indicata.
Rimuovere le batterie se il dispositivo non viene usato per
un periodo prolungato.
Uso di batterie ricaricabili
E' possibile usare questo dispositivo con batterie ricaricabili.
Usare esclusivamente batterie ricaricabili di tipo «NiMH».
Quando compare il simbolo di batteria scarica, è neces-
sario rimuovere le batterie e ricaricarle. Le batterie non
devono restare nel dispositivo, potrebbero danneggiarsi
(scaricamento totale anche quando il dispositivo è spento).
Informazione per il medico nel caso in cui il simbolo IHB
compaia ripetutamente:
Questo dispositivo è un misuratore di pressione oscillometrico
che durante la misurazione della pressione rileva anche il battito
cardiaco e segnala quando la frequenza cardiaca è irregolare.
29BP A3 Plus
IT
Rimuovere sempre le batterie ricaricabili se si prevede di non
usare il dispositivo per una settimana o un periodo più lungo.
Le batterie non possono essere caricate nel misuratore di
pressione! Ricaricare le batterie con un carica batterie
esterno e osservare le istruzioni del produttore su carica,
cura e durata.
8. Utilizzo del trasformatore
E' possibile usare il dispositivo con il trasformatore
Microlife
(
DC
6V, 600 mA
).
Usare esclusivamente il trasformatore Microlife disponibile
come accessorio originale, adatto alla tensione di utilizzo.
Controllare che né il trasformatore, né il cavo siano danneggiati.
1. Inserire il cavo del trasformatore nella presa prevista 5 del
misuratore di pressione.
2. Inserire la spina del trasformatore nella presa a muro.
Quando è collegato il trasformatore, le batterie non vengono consumate.
9. Messaggi di errore
In caso di errore durante la misurazione, questa viene interrotta e
viene visualizzato un messaggio di errore, es. «ERR 3».
* Consultare immediatamente il proprio medico se questo o altri
problemi si verificano ripetutamente.
Se si ritiene che i risultati siano diversi da quelli abituali,
leggere attentamente le informazioni del «capitolo 1.».
10.Sicurezza, cura, test di precisione e smaltimento
Sicurezza e protezione
Seguire le istruzioni d'uso. Questo manuale contiene informa-
zioni importanti sul funzionamento e la sicurezza di questo
dispositivo. Si prega di leggere attentamente le istruzioni d'uso
prima di utilizzare il dispositivo e di conservarle per ogni futura
consultazione.
Questo dispositivo deve essere usato esclusivamente come
descritto in questo manuale. Il produttore non può essere rite-
nuto responsabile di danni causati da un utilizzo improprio.
Questo dispositivo è costruito con componenti delicati e deve
essere trattato con attenzione. Osservare le condizioni di stoc-
caggio e funzionamento descritte nel capitolo «Specifiche
tecniche».
Proteggere il dispositivo da:
- acqua e umidità
- temperature estreme
- urti e cadute
- contaminazione e polvere
- luce solare diretta
- caldo e freddo
I bracciali sono delicati e devono essere trattati con cura.
Non sostituire o utilizzare altri bracciali o raccordi di altri produt-
tori per questo dispositivo.
Errore Descrizione Probabile causa e rimedio
«ERR 1» Segnale
troppo
debole
Le pulsazioni rilevate dal bracciale sono
troppo deboli. Riposizionare il bracciale
e ripetere la misurazione.*
«ERR 2»
BN
Segnale di
errore
Durante la misurazione sono stati rilevati
segnali di errore dal bracciale, causati
probabilmente da movimento o tensione
muscolare. Ripetere la misurazione,
tenendo fermo il braccio.
«ERR 3»
BK
Assenza di
pressione
nel brac-
ciale
Non è possibile generare una pressione
adeguata nel bracciale. Può esserci una
perdita. Controllare che il bracciale sia
correttamente collegato e non sia troppo
largo. Sostituire le batterie se neces-
sario. Ripetere la misurazione.
«ERR 5»Risultati
anomali
I segnali della misurazione non sono
accurati e la misurazione non può essere
visualizzata. Leggere le istruzioni per
l'esecuzione di una misurazione affida-
bile e ripetere la misurazione.*
«ERR 6» Modalità
MAM
Troppi errori durante la misurazione in
modalità
MAM
, che rendono impossibile
ottenere un risultato finale. Leggere le
istruzioni per l'esecuzione di una misura-
zione affidabile e ripetere la misurazione.*
«HI» Frequenza
o pressione
del brac-
ciale troppo
alte
La pressione nel bracciale è troppo alta
(superiore a 299 mmHg) o la frequenza
cardiaca è troppo alta (superiore a
200 battiti al minuto). Stare rilassati per
5 minuti e ripetere la misurazione.*
«LO» Frequenza
troppo
bassa
La frequenza cardiaca è troppo bassa
(inferiore a 40 battiti al minuto). Ripetere
la misurazione.*
Errore Descrizione Probabile causa e rimedio
30
Gonfiare il bracciale solo dopo averlo indossato.
Non usare il dispositivo vicino a forti campi elettromagnetici
come telefoni cellulari o installazioni radio. Mantenere una
distanza minima di 3,3 m da altri apparecchi quando si utilizza
questo dispositivo.
Non usare il dispositivo se si ritiene che sia danneggiato o se si
nota qualcosa di strano.
Non aprire mai il dispositivo.
Rimuovere le batterie se il dispositivo non viene usato per un
periodo prolungato.
Leggere le ulteriori informazioni sulla sicurezza nelle varie
sezioni di questo manuale.
La misurazione ottenuta con questo dispositivo non rappre-
senta una diagnosi. Non sostituisce la consultazione del proprio
medico curante, soprattutto se il risultato non è corrispondente
ai propri sintomi. Non fare affidamento solo sulla misurazione,
considerare sempre altri sintomi che potrebbero manifestarsi e
lo stato generale del paziente. Se necessario si consiglia di
chiamare un medico o un'ambulanza.
Assicurarsi che i bambini non utilizzino il dispositivo senza
la supervisione di un adulto. Alcune parti sono piccole e
potrebbero essere ingerite. Prestare attenzione al rischio di
strangolamento in presenza di cavi o tubi.
Cura del dispositivo
Pulire il dispositivo esclusivamente con un panno morbido e asciutto.
Pulizia del bracciale
Rimuovere con cautela eventuali tracce di sporco sul bracciale con
un panno inumidito con acqua e sapone.
AVVERTENZA: Non lavare il bracciale in lavatrice o lava-
stoviglie!
Test di precisione
Consigliamo di verificare la precisione di questo dispositivo ogni
2
anni o dopo un impatto meccanico (es. caduta). Contattare il locale
servizio consumatori
Microlife
per eseguire il test (vedi introduzione).
Smaltimento
Le batterie e gli strumenti elettronici devono essere smaltiti in
conformità alle disposizioni locali e non come i rifiuti domestici.
11.Garanzia
Questo dispositivo è coperto da una garanzia di 5 anni dalla data
di acquisto. Durante questo periodo di garanzia, a nostra discre-
zione, Microlife riparerà o sostituirà gratuitamente il prodotto difet-
toso.
L'apertura o la manomissione del dispositivo invalidano la
garanzia.
Sono esclusi dalla garanzia:
Costi e rischi di trasporto.
Danni causati da un uso scorretto o dal mancato rispetto delle
istruzioni d'uso.
Danni causati da perdite delle batterie.
Danni causati da caduta o uso improprio.
Materiale di imballaggio/stoccaggio e istruzioni d'uso.
Controlli regolari e manutenzione (calibrazione).
Accessori e parti soggette a usura: Batterie, alimentatore
(opzionale).
Il bracciale è coperto da una garanzia di funzionalità (tenuta della
camera d'aria) per 2 anni.
Qualora fosse necessario il servizio di assistenza in garanzia,
contattare il rivenditore da cui è stato acquistato il prodotto o il
servizio locale Microlife sul sito
www.microlife.com/support
Il risarcimento è limitato al valore del prodotto. La garanzia verrà
concessa se il prodotto completo viene restituito con la fattura o
scontrino originale. La riparazione o sostituzione in garanzia non
prolunga o rinnova il periodo di garanzia. Le rivendicazioni legali e
i diritti dei consumatori non sono limitati da questa garanzia.
31BP A3 Plus
IT
12.Specifiche tecniche
Questo dispositivo è conforme alla direttiva sui prodotti medicali
93/42/EEC.
Con riserva di apportare modifiche tecniche.
Condizioni di
esercizio:
10 - 40 °C / 50 - 104 °F
15 - 95 % umidità relativa massima
Condizioni di
stoccaggio:
-20 - +55 °C / -4 - +131 °F
15 - 95 % umidità relativa massima
Peso:
368 g (comprese batterie)
Dimensioni:
143 x 85 x 58 mm
Procedura di
misurazione:
oscillometrica, corrispondente al
metodo di Korotkoff: fase I sistolica,
fase V diastolica
Range di misurazione:
20 - 280 mmHg – pressione arteriosa
40 - 200 battiti al minuto – pulsazioni
Range pressione di
gonfiaggio del bracciale:
0 - 299 mmHg
Risoluzione:
1 mmHg
Precisione pressione
statica:
pressione entro ± 3 mmHg
Precisione pulsazioni:
± 5 % del valore letto
Alimentazione:
4 x batterie alcaline da 1,5 Volt; tipo AA
trasformatore DC 6V, 600 mA (optional)
Durata batterie: approssim. 920 misurazioni (usando
batterie nuove)
Classe IP: IP20
Riferimento agli
standard:
EN 1060-1 /-3 /-4; IEC 60601-1;
IEC 60601-1-2 (EMC); IEC 60601-1-11
Aspettativa di vita del
prodotto in uso:
Dispositivo: 5 anni o 10000 misurazioni
Accessori: 2 anni
32
Display
Vor Verwendung Bedienungsanleitung genau studieren.
Anwendungsteil des Typs BF
Verwendungszweck:
Dieses oszillometrische Blutdruckmessgerät dient zur Messung
des nicht-invasiven Blutdrucks bei Personen im Alter von 12
Jahren oder älter.
Es ist klinisch validiert bei Patienten mit Hypertonie, Hypotonie,
Diabetes, Schwangerschaft, Präeklampsie, Atherosklerose,
Nierenerkrankungen im Endstadium, Fettleibigkeit und ältere
Menschen.
Sehr geehrter Kunde,
Dieses Gerät wurde in Zusammenarbeit mit Ärzten entwickelt und
die hohe Messgenauigkeit ist klinisch getestet.*
Wenden Sie sich bei Fragen, Problemen oder Ersatzteilbedarf
jederzeit gerne an den lokalen Microlife-Service. Ihr Händler oder
Apotheker kann Ihnen die Adresse der Microlife-Landesvertretung
mitteilen. Eine Vielzahl nützlicher Informationen zu unseren
Produkten finden Sie auch im Internet unter www.microlife.com.
Wir wünschen Ihnen alles Gute für Ihre Gesundheit – Microlife AG!
* Dieses Gerät verwendet die gleiche Messtechnologie wie das
nach dem Protokoll der Britischen und Irischen Hochdruck Gesell-
schaft (BIHS) in London mit bester Auszeichnung getestete Modell
«BP 3BTO-A».
Microlife BP A3 Plus
DE
1
Ein-/Aus-Taste
2
Display
3
Manschetten-Anschluss
4
Batteriefach
5
Netzadapter-Anschluss
6
Manschette
7
Manschettenstecker
8
MAM-Schalter
9
Benutzerwechsel-Schalter
AT
M-Taste (Speicher)
AK
Uhrzeit-Taste
AL
Benutzeranzeige
AM
Batterieanzeige
AN
Datum/Uhrzeit
AO
Systolischer Wert
AP
Diastolischer Wert
AQ
Pulsschlag
AR
Ampel-Indikator
AS
MAM-Wartezeit
BT
Puls-Indikator
BK
Manschettenprüf-Indikator
BL
MAM-Modus
BM
Symbol für unregelmässigen Herzschlag (IHB)
BN
Armbewegungs-Indikator
BO
Speicherwert
Vor Nässe schützen
33BP A3 Plus
DE
Inhaltsverzeichnis
1. Wichtige Informationen zum Blutdruck und zur Selbst-
messung
Wie beurteile ich meinen Blutdruck?
2. Erste Inbetriebnahme des Geräts
Einlegen der Batterien
Einstellen von Datum und Uhrzeit
Auswahl der richtigen Manschette
Auswahl des Benutzers
Auswahl Normal- oder MAM-Modus
MAM-Modus (sehr zu empfehlen)
3. Durchführung einer Blutdruckmessung
Ein Messergebnis nicht speichern
4. Anzeige des Symbols für unregelmässigen Herzschlag
(IHB)
5. Ampelanzeige am Display
6. Messwertspeicher
Anzeigen der gespeicherten Werte
Speicher voll
Löschen aller Werte
7. Batterieanzeige und Batteriewechsel
Batterien bald leer
Batterien leer – Batterieaustausch
Welche Batterien und was beachten?
Verwendung wiederaufladbarer Batterien (Akkumulatoren)
8. Verwendung eines Netzadapters
9. Fehlermeldungen und Probleme
10. Sicherheit, Pflege, Genauigkeits-Überprüfung und Entsor-
gung
Sicherheit und Schutz
Pflege des Gerätes
Reinigung der Manschette
Genauigkeits-Überprüfung
•Entsorgung
11. Garantie
12. Technische Daten
Garantiekarte (siehe Rückseite)
1. Wichtige Informationen zum Blutdruck und zur
Selbstmessung
Blutdruck ist der Druck des in den Blutgefässen fliessenden
Blutes, verursacht durch das Pumpen des Herzens. Es werden
immer zwei Werte gemessen, der systolische (obere) Wert
und der diastolische (untere) Wert.
Das Gerät gibt Ihnen ausserdem den Pulswert an (wie oft das
Herz in der Minute schlägt).
Auf Dauer erhöhte Blutdruckwerte können zu Gesund-
heitsschäden führen und müssen deshalb von Ihrem Arzt
behandelt werden!
Besprechen Sie Ihre Werte, besondere Auffälligkeiten oder
Unklarheiten immer mit Ihrem Arzt. Verlassen Sie sich
niemals nur auf die Blutdruckmesswerte allein.
Es gibt mehrere Ursachen für zu hohe Blutdruckwerte. Ihr
Arzt wird Sie genauer darüber informieren und bei Bedarf
entsprechend behandeln. Neben Medikamenten können z.B.
Gewichtsabnahme oder Sport Ihren Blutdruck senken.
Verändern Sie unter keinen Umständen die Dosierung von
Medikamenten oder beginnen Sie keine Behandlung ohne
Rücksprache mit Ihrem Arzt.
Je nach Anstrengung und Befinden während des Tagesver-
laufs unterliegt der Blutdruck starken Schwankungen. Messen
Sie deshalb täglich unter ruhigen und vergleichbaren
Bedingungen und wenn Sie sich entspannt fühlen! Nehmen
Sie jedes Mal mindestens zwei Messungen vor (am Morgen
und am Abend) und berechnen Sie den Durchschnittswert.
Es ist normal, dass bei kurz hintereinander durchgeführten
Messungen deutliche Unterschiede auftreten können. Wir
empfehlen deshalb, die MAM-Technologie zu verwenden.
Abweichungen zwischen der Messung beim Arzt oder in der
Apotheke und zu Hause sind normal, da Sie sich in ganz unter-
schiedlichen Situationen befinden.
Mehrere Messungen ergeben viel zuverlässigere Informati-
onen über Ihren Blutdruck als nur eine Einzelmessung. Wir
empfehlen deshalb, die MAM-Technologie zu verwenden.
Machen Sie zwischen zwei Messungen eine kurze Pause von
mindestens 15 Sekunden.
Wenn Sie an einer Herzrhythmusstörung leiden, wenden Sie
sich an Ihren Arzt, bevor Sie das Gerät verwenden. Siehe auch
Kapitel «Anzeige des Symbols für unregelmässigen Herz-
schlag (IHB)» in dieser Bedienungsanleitung.
34
Die Pulsanzeige ist nicht geeignet zur Kontrolle der
Frequenz von Herzschrittmachern!
Während der Schwangerschaft sollten Sie Ihren Blutdruck
regelmässig kontrollieren, da er deutlich variieren kann!
Dieses Blutdruckmessgerät ist speziell für den Gebrauch
während der Schwangerschaft und bei Präeklampsie
getestet. Wenn Sie ungewöhnlich hohe Werte während der
Schwangerschaft messen, sollten Sie nach einer kurzen
Weile (z.B. 1 Stunde) noch einmal messen. Wenn der Wert
immer noch zu hoch ist, konsultieren Sie Ihren Arzt oder
Gynäkologen.
Wie beurteile ich meinen Blutdruck?
Für die Bewertung ist immer der höhere Wert entscheidend.
Beispiel: bei den Messwerten von 140/80 mmHg oder 130/90
mmHg zeigt es «zu hoher Blutdruck» an.
2. Erste Inbetriebnahme des Geräts
Einlegen der Batterien
Nachdem Sie das Gerät ausgepackt haben, legen Sie die Batterien
ein. Das Batteriefach
4
befindet sich auf der Geräteunterseite.
Legen Sie die Batterien (
4
x 1,5 V, Grösse
AA
) ein und achten Sie
dabei auf die angezeigte Polarität.
Einstellen von Datum und Uhrzeit
1. Nachdem neue Batterien eingelegt wurden, blinkt die Jahres-
zahl im Display. Sie können durch Drücken der M-Taste AT das
Jahr einstellen. Drücken Sie zur Bestätigung und um zur
Monatseinstellung zu wechseln die Uhrzeit-Taste AK.
2. Der Monat kann nun durch die M-Taste eingestellt werden.
Drücken Sie zur Bestätigung und um zur Tageseinstellung zu
wechseln die Uhrzeit-Taste.
3. Gehen Sie weiter wie oben beschrieben vor, um Tag, Stunde
und Minuten einzustellen.
4. Nachdem als letztes die Minuten eingestellt sind und die
Uhrzeit-Taste AK gedrückt wurde, sind Datum und Uhrzeit
eingestellt und die Zeit wird angezeigt.
5. Wenn Sie Datum und Uhrzeit einmal ändern möchten, halten
Sie die Uhrzeit-Taste ca. 3 Sekunden lang gedrückt, bis die
Jahreszahl zu blinken beginnt. Nun können Sie wie zuvor
beschrieben die neuen Werte eingeben.
Auswahl der richtigen Manschette
Microlife bietet Ihnen verschiedene Manschettengrössen zur
Auswahl. Massgebend ist der Umfang des Oberarms (eng anlie-
gend, gemessen in der Mitte des Oberarms).
Vorgeformte Manschetten «Easy» sind für bessere Pass-
form und Komfort optional erhältlich.
Verwenden Sie ausschliesslich Microlife Manschetten!
Sollte die beiliegende Manschette 6 nicht passen, wenden Sie
sich bitte an den lokalen Microlife Service.
Verbinden Sie die Manschette mit dem Gerät, indem Sie den
Stecker 7 fest bis zum Anschlag in die Manschettenbuchse 3
einstecken.
Auswahl des Benutzers
Dieses Gerät speichert die Daten für 2 individuelle Benutzer.
Vor jedem Messvorgang: schieben Sie den Benutzerwechsel-
Schalter 9 auf den gewünschten Benutzer: Benutzer 1 oder 2.
Benutzer 1: Schieben Sie den Schalter 9 nach oben zum
Symbol «Benutzer 1».
Benutzer 2: Schieben Sie den Schalter 9 nach unten zum
Symbol «Benutzer 2».
Tabelle zur Klassifizierung von zuhause gemessenen Blutdruck-
werten in Übereinstimmung mit den internationalen Richtlinien
(ESH, ESC, JSH). Werte in mmHg.
Bereich
Systo-
lisch
Diasto-
lisch Empfehlung
1. normaler Blutdruck < 120 < 74 Selbstkontrolle
2. optimaler Blut-
druck
120 - 129 74 - 79 Selbstkontrolle
3. erhöhter Blutdruck 130 - 134 80 - 84 Selbstkontrolle
4. zu hoher Blutdruck 135 - 159 85 - 99 Ärztliche Kont-
rolle
5. schwerer Blut-
hochdruck
160 100 Dringende ärzt-
liche Kontrolle!
Manschettengrösse für Oberarmumfang
S 17 - 22 cm
M 22 - 32 cm
M - L 22 - 42 cm
L 32 - 42 cm
L - XL 32 - 52 cm
35BP A3 Plus
DE
Die zuerst messende Person sollte Benutzer 1 wählen.
Auswahl Normal- oder MAM-Modus
Sie können bei diesem Gerät wählen, ob Sie die Messung im
Normal-Modus (normale Einfach-Messung) oder im MAM-Modus
(automatische Dreifach-Messung) durchführen möchten. Für den
Normal-Modus schieben Sie den MAM-Schalter 8 an der Seite
des Geräts auf Position «1» nach unten, für den MAM-Modus auf
Position «3» nach oben.
MAM-Modus (sehr zu empfehlen)
Im
MAM
-Modus werden automatisch 3 Messungen nachein-
ander durchgeführt und danach wird das Ergebnis automatisch
analysiert und angezeigt. Da der Blutdruck ständig schwankt ist
ein so ermitteltes Ergebnis zuverlässiger als eine Einzelmessung.
Wenn Sie die Dreifach-Messung auswählen, erscheint das
MAM-Symbol BL im Display.
Rechts unten im Display wird durch 1, 2 oder 3 angezeigt,
welche der 3 Messungen gerade durchgeführt wird.
Zwischen den einzelnen Messungen erfolgt eine Pause von je
15 Sekunden. Ein Countdown zeigt die verbleibende Zeit an.
Die Einzelergebnisse werden nicht angezeigt. Der Blutdruck-
wert wird angezeigt, nachdem alle 3 Messungen durchgeführt
wurden.
Lassen Sie die Manschette zwischen den Messungen angelegt.
Falls eine Einzelmessung fehlerhaft war, wird automatisch eine
vierte Messung durchgeführt.
3. Durchführung einer Blutdruckmessung
Checkliste für die Durchführung einer zuverlässigen
Messung
1. Vermeiden Sie kurz vor der Messung Anstrengung, Essen und
Rauchen.
2. Setzen Sie sich auf einen Stuhl mit Rückenlehne und
entspannen Sie sich für 5 Minuten. Halten Sie die Füsse flach
auf dem Boden und kreuzen Sie Ihre Beine nicht.
3. Messen Sie immer am gleichen Arm (normalerweise am
Linken). Es wird empfohlen, dass Ärzte beim ersten Besuch
des Patienten an beiden Armen messen, um zu bestimmen, an
welchem Arm in Zukunft gemessen werden soll. Wählen Sie
den Arm mit dem höheren Blutdruck.
4. Legen Sie einengende Kleidungsstücke am Oberarm ab. Ein Hemd
sollte zur Vermeidung von Einschnürungen nicht hochgekrempelt
werden - glatt anliegend stört es unter der Manschette nicht.
5. Stellen Sie sicher, dass immer die korrekte Manschettengrösse
gebraucht wird (Markierung auf der Manschette).
Legen Sie die Manschette eng aber nicht zu stramm an.
Stellen Sie sicher, dass die Manschette 1-2 cm über der
Ellenbeuge positioniert ist.
Die Arterienmarkierung auf der Manschette (ca. 3 cm
langer Balken) muss über der Arterie liegen, welche auf der
Innenseite des Armes entlang läuft.
Stützen Sie den Arm zur Entspannung ab.
Achten Sie darauf, dass sich die Manschette auf Herzhöhe
befindet.
6. Starten Sie die Messung durch Drücken der Ein/Aus-Taste 1.
7. Die Manschette wird nun automatisch aufgepumpt.
Entspannen Sie sich, bewegen Sie sich nicht und spannen Sie
die Armmuskeln nicht an bis das Ergebnis angezeigt wird.
Atmen Sie ganz normal und sprechen Sie nicht.
8. Wenn der richtige Druck erreicht ist, stoppt das Aufpumpen und
der Druck fällt allmählich ab. Sollte der Druck nicht ausreichend
gewesen sein, pumpt das Gerät automatisch nach.
9. Während der Messung blinkt der Puls-Indikator BT im Display.
10.Das Ergebnis, bestehend aus systolischem AO und diastoli-
schem AP Blutdruck sowie dem Pulsschlag AQ, wird angezeigt.
Beachten Sie auch die Erklärungen zu weiteren Display-
Anzeigen in dieser Anleitung.
11.Entfernen Sie die Manschette nach der Messung vom Gerät.
12.Schalten Sie das Gerät aus. (Auto-Aus nach ca. 1 Min.).
Ein Messergebnis nicht speichern
Sobald das Resultat auf dem Display erscheint, drücken und
halten Sie die Ein/Aus-Taste 1 bis «M» BO blinkt. Bestätigen Sie
den Löschvorgang indem Sie die M-Taste AT drücken.
Sie können die Messung jederzeit durch Drücken der Ein/
Aus-Taste abbrechen (z.B. Unwohlsein oder unange-
nehmer Druck).
Bei bekanntem sehr hohem systolischem Blutdruck
kann es von Vorteil sein, den Druck selbst vorzugeben.
Drücken Sie dazu die Ein/Aus-Taste nachdem das Gerät
mit dem Aufpumpen begonnen hat und ein Druckwert von
ca. 30 mmHg im Display angezeigt wird. Halten Sie die
Taste gedrückt bis der Druck ca. 40 mmHg über dem erwar-
teten systolischen Wert ist und lassen die Taste dann los.
36
4. Anzeige des Symbols für unregelmässigen Herz-
schlag (IHB)
Dieses Symbol BM zeigt an, dass ein unregelmäßiger Herzschlag
festgestellt wurde. In diesem Fall kann der gemessene Blutdruck
von Ihren tatsächlichen Blutdruckwerten abweichen. Es wird
empfohlen, die Messung zu wiederholen.
5. Ampelanzeige am Display
Die Balken
AR
am linken Rand des Displays zeigen Ihnen den
Bereich an, in dem Ihr Blutdruckwert liegt. Abhängig von der Höhe
der Balken ist der gemessene Wert entweder optimal (grün), erhöht
(gelb), zu hoch (orange) oder gefährlich hoch (rot). Die Klassifizie-
rung orientiert sich an den
4
Bereichen in der Tabelle der internatio-
nalen Richtlinien (
ESH, ESC, JSH
), wie in «Kapitel 1.» beschrieben.
6. Messwertspeicher
Dieses Gerät speichert automatisch bis zu 99 Messwerte pro
Benutzer.
Anzeigen der gespeicherten Werte
Wählen Sie Benutzer 1 oder 2 mit dem Benutzerwechsel-Schalter
9
aus.
Drücken Sie kurz die M-Taste
AT
, während das Gerät ausgeschaltet
ist. Das Display zeigt zuerst «
M
»
BO
und «
A
» an, was für den Durch-
schnittwert aller gespeicherten Werte steht.
Nochmaliges Drücken der M-Taste zeigt den vorherigen Wert an.
Durch wiederholtes Drücken der M-Taste können Sie von einem
zum anderen Speicherwert wechseln.
Speicher voll
Achten Sie darauf, dass die maximale Speicherkapazität
von 99 Werten pro Benutzer nicht überschritten wird. Wenn
der Speicher voll ist, wird der älteste Wert automatisch
mit dem 100. Wert überschrieben. Die Werte sollten von
einem Arzt kontrolliert werden, bevor die volle Speicherka-
pazität erreicht ist – ansonsten gehen die Daten verloren.
Löschen aller Werte
Stellen Sie sicher, dass Sie den richtigen Benutzer ausgewählt
haben.
1. Wählen Sie Benutzer 1 oder 2 mit dem Benutzerwechsel-
Schalter 9 aus, während das Gerät ausgeschaltet ist.
2. Halten Sie die M-Taste AT gedrückt bis «CL» erscheint und
lassen Sie dann los.
3. Drücken Sie die M-Taste während «CL» blinkt, um alle Werte
des ausgewählten Benutzers endgültig zu löschen.
Abbruch des Löschvorgangs: Drücken Sie die Ein/Aus-
Taste 1 während «CL» blinkt.
Einzelne Werte können nicht gelöscht werden.
7. Batterieanzeige und Batteriewechsel
Batterien bald leer
Wenn die Batterien zu etwa ¾ aufgebraucht sind, blinkt gleich nach
dem Einschalten das Batteriesymbol
AM
(teilweise gefüllte Batterie).
Sie können weiterhin zuverlässig mit dem Gerät messen, sollten
aber Ersatzbatterien besorgen.
Batterien leer – Batterieaustausch
Wenn die Batterien aufgebraucht sind, blinkt gleich nach dem Ein-
schalten das leere Batteriesymbol AM. Sie können keine Messung
mehr durchführen und müssen die Batterien austauschen.
1. Öffnen Sie das Batteriefach 4 an der Geräteunterseite.
2. Tauschen Sie die Batterien aus – achten Sie auf die richtige
Polung wie auf den Symbolen im Fach dargestellt.
3. Stellen Sie das Datum und Uhrzeit wie im «Kapitel 2.»
beschrieben ein.
Alle Werte bleiben im Speicher, jedoch Datum und Uhrzeit
müssen neu eingestellt werden – deshalb blinkt nach dem
Batteriewechsel automatisch die Jahreszahl.
Welche Batterien und was beachten?
Verwenden Sie 4 neue, langlebige 1,5 V Alkaline-Batterien,
Grösse AA.
Verwenden Sie Batterien nicht über das angegebene Halt-
barkeitsdatum hinaus.
Entfernen Sie die Batterien, wenn das Gerät für längere
Zeit nicht benutzt wird.
Verwendung wiederaufladbarer Batterien (Akkumulatoren)
Sie können dieses Gerät auch mit wiederaufladbaren Batterien
betreiben.
Hinweise für den Arzt bei wiederholtem Auftreten des IHB-
Symbols:
Dieses Gerät ist ein oszillometrisches Blutdruckmessgerät, das
auch den Puls während der Blutdruckmessung misst und
anzeigt wenn der Herzschlag unregelmässig ist.
37BP A3 Plus
DE
Verwenden Sie nur wiederaufladbare «NiMH»-Batterien.
Wenn das Batteriesymbol (Batterie leer) angezeigt wird,
müssen die Batterien herausgenommen und aufgeladen
werden. Sie dürfen nicht im Gerät verbleiben, da sie
zerstört werden könnten (Tiefenentladung durch geringen
Verbrauch des Gerätes auch im ausgeschalteten Zustand).
Nehmen Sie wiederaufladbare Batterien unbedingt aus dem
Gerät, wenn Sie es für eine Woche oder länger nicht benutzen.
Die Batterien können NICHT im Blutdruckmessgerät aufge-
laden werden. Laden Sie die Batterien in einem externen
Ladegerät auf und beachten Sie die Hinweise zur Ladung,
Pflege und Haltbarkeit.
8. Verwendung eines Netzadapters
Sie können dieses Gerät mit dem Microlife Netzadapter (DC 6V,
600 mA) betreiben.
Verwenden Sie nur den als Original-Zubehör erhältlichen
Microlife Netzadapter entsprechend Ihrer Netzspannung.
Stellen Sie sicher, dass Netzadapter und Kabel keine
Beschädigungen aufweisen.
1. Stecken Sie das Adapterkabel in den Netzadapter-Anschluss
5
des Blutdruckmessgerätes.
2. Stecken Sie den Adapterstecker in die Steckdose.
Wenn der Netzadapter angeschlossen ist, wird kein Batteriestrom
verbraucht.
9. Fehlermeldungen und Probleme
Wenn bei der Messung ein Fehler auftritt, wird die Messung abge-
brochen und eine Fehlermeldung, z.B. «ERR 3», angezeigt.
* Sprechen Sie umgehend mit Ihrem Arzt, wenn diese oder andere
Probleme wiederholt auftreten sollten.
Wenn Ihnen die Ergebnisse ungewöhnlich erscheinen,
beachten Sie bitte sorgfältig die Hinweise in «Kapitel 1.».
10.Sicherheit, Pflege, Genauigkeits-Überprüfung und
Entsorgung
Sicherheit und Schutz
Befolgen Sie diese Gebrauchsanweisung. Dieses Dokument
enthält wichtige Informationen zum Betrieb und zur Sicherheit
dieses Geräts. Bitte lesen Sie dieses Dokument sorgfältig
durch, bevor Sie das Gerät benutzen und bewahren Sie es für
die zukünftige Nutzung auf.
Fehler Bezeichnung Möglicher Grund und Abhilfe
«ERR 1» Zu schwa-
ches Signal
Die Pulssignale an der Manschette sind
zu schwach. Legen Sie die Manschette
erneut an und wiederholen die Messung.*
«ERR 2»
BN
Störsignal Während der Messung wurden Störsig-
nale an der Manschette festgestellt,
z.B. durch Bewegen oder Muskelan-
spannung. Halten Sie den Arm ruhig
und wiederholen Sie die Messung.
«ERR 3»
BK
Kein Druck in
der
Manschette
Der Manschettendruck kann nicht
ausreichend aufgebaut werden. Even-
tuell liegt eine Undichtigkeit vor. Prüfen
Sie, ob die Manschette richtig verbunden
ist und nicht zu locker anliegt. Eventuell
Batterien austauschen. Wiederholen Sie
danach die Messung.
«ERR 5» Anormales
Ergebnis
Die Messsignale sind ungenau und es
kann deshalb kein Ergebnis angezeigt
werden. Beachten Sie die Checkliste
zur Durchführung zuverlässiger
Messungen und wiederholen danach
die Messung.*
«ERR 6» MAM-Modus
Es gab zu viele Fehler während der
Messung im
MAM
-Modus, so dass kein
Endergebnis ermittelt werden kann.
Beachten Sie die Checkliste zur Durch-
führung zuverlässiger Messungen und
wiederholen danach die Messung.*
«HI» Puls oder
Manschet-
tendruck zu
hoch
Der Druck in der Manschette ist zu hoch
(über 299 mmHg) oder der Puls ist zu
hoch (über 200 Schläge pro Minute).
Entspannen Sie sich 5 Minuten lang und
wiederholen Sie die Messung.*
«LO» Puls zu
niedrig
Der Puls ist zu niedrig (unter
40 Schläge pro Minute). Wiederholen
Sie die Messung.*
Fehler Bezeichnung Möglicher Grund und Abhilfe
38
Dieses Gerät darf nur für den in dieser Anleitung beschriebenen
Zweck verwendet werden. Der Hersteller ist nicht für Schäden
haftbar, die aus unsachgemässer Handhabung resultieren.
Dieses Gerät besteht aus sensiblen Bauteilen und muss
vorsichtig behandelt werden. Beachten Sie die Lager- und
Betriebsanweisungen im Kapitel «Technische Daten».
Schützen Sie das Gerät vor:
- Wasser und Feuchtigkeit
- extremen Temperaturen
- Stössen und Herunterfallen
- Schmutz und Staub
- starker Sonneneinstrahlung
- Hitze und Kälte
Die Manschette ist empfindlich und muss schonend behandelt
werden.
Verwenden Sie keine anderen Manschetten oder Manschetten-
stecker für die Messung mit diesem Gerät.
Pumpen Sie die Manschette erst auf, wenn sie angelegt ist.
Benutzen Sie das Gerät nicht in der Nähe starker elektromag-
netischer Felder wie z.B. Mobiltelefone oder Funkanlagen.
Halten Sie einen Mindestabstand von 3,3 m zu solchen
Geräten, wenn Sie dieses Gerät benutzen.
Benutzen Sie das Gerät nicht, wenn Sie einen Schaden
erkennen oder Ihnen etwas Ungewöhnliches auffällt.
Öffnen Sie niemals das Gerät.
Entfernen Sie die Batterien, wenn das Gerät für längere Zeit
nicht benutzt wird.
Beachten Sie die weiteren Sicherheitshinweise in den
einzelnen Kapiteln dieser Anleitung.
Das von diesem Gerät angezeigte Messergebnis ist keine
Diagnose. Es ersetzt nicht die Notwendigkeit einer fachlichen
Einschätzung durch einen Mediziner, vor allem dann nicht,
wenn das Ergebnis nicht dem Befinden des Patienten
entspricht. Verlassen Sie sich nicht ausschliesslich auf das
Messergebnis. Alle potenziell auftretenden Symptome und die
Schilderung des Patienten müssen in Betracht gezogen
werden. Die Verständigung eines Arztes oder Krankenwagens
wird bei Bedarf empfohlen.
Sorgen Sie dafür, dass Kinder das Gerät nicht unbeaufsich-
tigt benutzen; einige Teile sind so klein, dass sie
verschluckt werden könnten. Beachten Sie das Strangulie-
rungsrisiko sollte dieses Gerät mit Kabeln oder Schläuchen
ausgestattet sein.
Pflege des Gerätes
Reinigen Sie das Gerät nur mit einem weichen, trockenen Lappen.
Reinigung der Manschette
Entfernen Sie Verunreinigungen vorsichtig mit einem feuchten
Tuch und Seife.
WARNUNG: Waschen Sie die Manschette niemals in einer
Waschmaschine oder in einem Geschirrspüler!
Genauigkeits-Überprüfung
Wir empfehlen alle 2 Jahre oder nach starker mechanischer Bean-
spruchung (z.B. fallen lassen) eine Genauigkeits-Überprüfung
dieses Gerätes durchführen zu lassen. Bitte wenden Sie sich dazu
an den lokalen Microlife-Service (siehe Vorwort).
Entsorgung
Batterien und elektronische Geräte dürfen nicht in den
Hausmüll, sondern müssen entsprechend den örtlichen
Vorschriften entsorgt werden.
11.Garantie
Für dieses Gerät gewähren wir 5 Jahre Garantie ab Kaufdatum.
Während der Garantiezeit repariert oder ersetzt Microlife, nach
eigenem Ermessen, das defekte Produkt kostenlos.
Wurde das Gerät durch den Benutzer geöffnet oder verändert,
erlischt der Garantieanspruch.
Folgende Punkte sind von der Garantie ausgenommen
Transportkosten und Transportrisiken
Schäden die durch falsche Anwendung oder Nichteinhaltung
der Gebrauchsanweisung verursacht wurden
Schäden durch auslaufende Batterien
Schäden durch Unfall oder Missbrauch
Verpackungs- / Lagermaterial und Gebrauchsanweisung
Regelmässige Kontrollen und Wartung (Kalibrierung)
Zubehör und Verschleissteile: Batterien, Netzteil (optional).
Für die Manschette gilt eine Funktionsgarantie (Blasendichtheit)
von 2 Jahren.
Sollte ein Garantiefall eintreten, wenden Sie sich bitte an den
Händler, bei dem das Produkt gekauft wurde oder an Ihren lokalen
Microlife-Service. Sie können Ihren lokalen Microlife-Service über
unsere Website kontaktieren:
www.microlife.com/support
Die Entschädigung ist auf den Wert des Produkts begrenzt. Die
Garantie wird gewährt, wenn das vollständige Produkt mit der
39BP A3 Plus
DE
Originalrechnung zurückgesandt wird. Eine Reparatur oder ein
Austausch innerhalb der Garantiezeit verlängert oder erneuert die
Garantiezeit nicht. Die gesetzlichen Ansprüche und Rechte der
Verbraucher sind durch die Garantie nicht eingeschränkt.
12.Technische Daten
Dieses Gerät entspricht den Anforderungen der Richtlinie für
Medizinische Geräte 93/42/EWG.
Technische Änderungen vorbehalten.
Betriebsbedin-
gungen:
10 - 40 °C / 50 - 104 °F
15 - 95 % relative maximale Luftfeuchtigkeit
Aufbewahrungs-
bedingungen:
-20 - +55 °C / -4 - +131 °F
15 - 95 % relative maximale Luftfeuchtigkeit
Gewicht:
368 g (mit Batterien)
Grösse:
143 x 85 x 58 mm
Messverfahren:
oszillometrisch, validiert nach Korotkoff-
Methode: Phase I systolisch, Phase V dias-
tolisch
Messbereich:
20 - 280 mmHg – Blutdruck
40 - 200 Schläge pro Minute – Puls
Displaybereich
Manschettendruck:
0 - 299 mmHg
Messauflösung:
1 mmHg
Statische
Genauigkeit:
Druck innerhalb ± 3 mmHg
Pulsgenauigkeit:
± 5 % des Messwertes
Spannungsquelle:
4 x 1,5 V Alkaline-Batterien, Grösse AA
Netzadapter DC 6V, 600 mA (optional)
Batterie-
Lebensdauer:
ca. 920 Messungen (mit neuen Batterien)
IP Klasse:
IP20
Verweis auf
Normen:
EN 1060-1 /-3 /-4; IEC 60601-1;
IEC 60601-1-2 (EMC); IEC 60601-1-11
Durchschnittliche
Lebensdauer:
Gerät: 5 Jahre oder 10000 Messungen
Zubehör: 2 Jahre
40
Ekran
Aygıtı kullanmadan önce, talimatları dikkatle okuyun.
BF tipi ekipman
Kullanım amacı:
Bu osilometrik tansiyon aletinin kullanım amacı, 12 yaşından
büyük kişilerin girişimsel olmayan kan basıncının ölçülmesidir.
Hipertansiyon, hipotansiyon, diyabet, gebe, preeklampsi, aterosk-
leroz, son dönem böbrek hastalığı, obezite olan hastalarda ve
yaşlı insanlarda klinik olarak doğrulandı.
Sayın Müşterimiz,
Aygıt, hekimlerle işbirliği içerisinde geliştirilmiştir ve yapılan
bilimsel testlerin sonucunda ölçüm doğruluğunun oldukça yüksek
olduğu kanıtlanmıştır.*
Sorularınız, sorunlarınız ve yedek parça siparişleriniz için, lütfen,
yerel Microlife-Müşteri Servisi ile görüşün. Ülkenizdeki Microlife bayi-
sinin adresini satıcınızdan ya da eczanenizden öğrenebilirsiniz. İkinci
bir yol olarak, ürünlerimiz hakkında geniş bilgi edinebileceğiniz
www.microlife.com internet adresini de ziyaret edebilirsiniz.
Sağlıkla kalın – Microlife AG!
* Bu aygıt, İngiliz Hipertansiyon Cemiyeti - British and Irish Hyper-
tension Society (BIHS) - protokolüne uygun olarak test edilen ödül
sahibi «BP 3BTO-A» modeli ile aynı ölçüm teknolojisine sahiptir.
Microlife BP A3 Plus
TR
1
AÇ/KAPA Düğmesi
2
Ekran
3
Kaf Soketi
4
Pil Bölmesi
5
Elektrik Adaptörü Soketi
6
Kaf
7
Kaf Bağlantısı
8
MAM Anahtarı
9
Kullanıcı Anahtarı
AT
M-Düğme (Bellek)
AK
Zaman Düğmesi
AL
Kullanıcı Göstergesi
AM
Pil Göstergesi
AN
Tarih/Saat
AO
Büyük Tansiyon Değeri
AP
Küçük Tansiyon Değeri
AQ
Nabız Sayısı
AR
Trafik Işığı Göstergesi
AS
MAM Zaman Aralığı
BT
Nabız Göstergesi
BK
Kaf Onay Göstergesi
BL
MAM Modu
BM
Düzensiz Kalp Atışı (IHB) Sembolü
BN
Kol Hareketi Göstergesi
BO
Kaydedilen Değer
Kuru tutun
41BP A3 Plus
TR
İçindekiler
1. Tansiyon Ölçümü ve Kendi Kendine Ölçüm Hakkında
Önemli Gerçekler
Tansiyonumu nasıl değerlendirebilirim?
2. Aygıtın İlk Kez Kullanımı
Pillerin yerleştirilmesi
Tarih ve saatin ayarlanması
•Doğru kaf seçimi
Kullanıcının seçilmesi
Standart veya MAM modunun seçilmesi
MAM modu (Tavsiye edilen)
3. Tansiyonun Ölçülmesi
Ölçüm sonucu nasıl silinir?
4. Düzensiz Kalp Atışı (IHB) Sembolünün Görünümü
5. Ekranda Trafik Işığı Göstergesi
6. Veri Belleği
Kaydedilen değerlerin görüntülenmesi
Bellek dolu
•Tüm değerlerin silinmesi
7. Pil Göstergesi ve Pil değişimi
Piller neredeyse bitmiş
Piller bitmiş – pillerin değiştirilmesi
Hangi piller ve yöntem?
Şarj edilebilir pillerin kullanılması
8. Elektrik Adaptörünün Kullanılması
9. Hata İletileri
10. Güvenlik, Bakım, Doğruluk Testi ve Elden Çıkarma
Güvenlik ve koruma
•Aygı
tın bakımı
•Kafın temizlenmesi
•Doğruluk testi
Elden çıkarma
11. Garanti Kapsamı
12. Teknik Özellikler
Garanti Belgesi (bkz Arka Kapak)
1. Tansiyon Ölçümü ve Kendi Kendine Ölçüm
Hakkında Önemli Gerçekler
Tansiyon ile, kalp tarafından pompalanan ve atardamarlardan
akan kanın basıncı ifade edilmektedir. Her zaman iki değer olan
büyük tansiyon (üst) değeri ve küçük tansiyon (alt) değerinin
ölçümleri yapılır.
Aygıt, aynı zamanda, nabız sayısını da gösterir (kalbin bir daki-
kadaki atış sayısı).
Sürekli yüksek tansiyon değerleri, sağlığınıza zarar vere-
bilir ve doktorunuz tarafından tedavi edilmesi gerekir!
Ölçüm değerlerini her zaman doktorunuza bildirin ve olağandışı
bir şey fark ettiğinizde ya da emin olmadığınız bir durum söz
konusu olduğunda doktorunuza danışın. Kesinlikle tek bir
tansiyon ölçüm sonucuna güvenmeyin.
Normalin üzerindeki yüksek tansiyon değerlerinden
kaynak-
lanan birçok durum söz konusudur. Doktorunuz, bunları ayrın-
tılarıyla açıklayacak ve gerekli görürse tedavi edilmelerini
önerecektir. İlaç tedavisinin yanı sıra, kilo vererek ve egzersiz
yaparak da tansiyonunuzu düşürebilirsiniz.
Hiçbir sart altında ilaçlarınızın dozunu artırmamalı ve
doktorunuza danışmadan bir tedaviye başlamamalısınız.
Bedensel efor ve kondisyona bağlı olarak, tansiyonda günden
güne geniş dalgalanmalar yaşanabilir. Bu nedenle, ölçümleri-
nizi her zaman sakin bir ortamda ve kendinizi rahat hisset-
tiğinizde yapmalısınız! En azından her seferinde iki kez ölçüm
yapınız (sabah ve akşam) ve ölçümlerinizin ortalamasını alınız.
Kısa aralıklarla yapılan iki ölçüm sonrasında, oldukça farklı
sonuçlar alınması son derece normaldir. Bundan dolayı MAM
teknolojisinin kullanılmasını öneririz.
Doktorunuz ya da eczacınız tarafından veya evde yapılan
ölçümler arasındaki sapmalar, söz konusu durumlar tamamen
farklı olduğu için, oldukça normaldir.
Tek ölçüm yerine, bir kaç ölçüm yapmak size kan basıncınız
hakkında daha güvenilir veriler sunar. Bundan dolayı MAM
teknolojisinin kullanılmasını öneririz.
İki ölçüm arasında en az 15 saniyelik kısa bir ara verin.
Kardiyak aritminiz varsa, cihazı kullanmadan önce doktorunuza
danışın. Ayrıca bu kullanım kılavuzunun «Düzensiz Kalp Atışı
(IHB) Sembolünün Görünümü» bölümüne bakın.
Nabız göstergesi, kalp pillerinin frekansının kontrolü için
uygun değildir!
42
Hamilelik döneminde çok değişiklik gösterdiği için tansiyonu-
nuzu düzenli kontrol etmeniz gerekmektedir.
Bu cihaz özellikle hamilelerde ve preeklampsi kullanımları
için test edilmiştir. Hamilelik sürecinde çok yüksek ölçümler
alırsanız, 1 saat ara ile tekrar ölçüm yapınız. Sonuç hala
çok yüksek ise, doktorunuza başvurunuz.
Tansiyonumu nasıl değerlendirebilirim?
Değerlendirmeyi belirleyen, daha yüksek olan değerdir. Örneğin:
Kan basıncı 140/80 mmHg değeri veya değeri 130/90 mmHg,
«tansiyon oldukça yüksek» gösterir.
2. Aygıtın İlk Kez Kullanımı
Pillerin yerleştirilmesi
Aygıtın ambalajını açtıktan sonra, ilk önce pilleri yerleştirin. Pil
bölmesi 4, aygıtın alt tarafındadır. Pilleri (4 x AA 1.5 V boyutunda)
yerleştirin; bunu yaparken kutupların gösterildiği gibi doğru
konumda bulunmasına dikkat edin.
Tarih ve saatin ayarlanması
1. Yeni piller takılınca, yıl sayısı ekranda yanıp söner. M-düğme-
sine AT basarak yılı ayarlayabilirsiniz. Ayı teyit edip ayarlamak
için, zaman düğmesine AK basın.
2. M-düğmesini kullanarak şimdi ayı ayarlayabilirsiniz. Günü teyit
etmek ve ayarlamak için, zaman düğmesine basın.
3. Günü, saati ve dakikayı ayarlamak için, lütfen, yukarıdaki tali-
matları uygulayın.
4. Dakikayı ayarlayıp zaman düğmesine bast
ıktan sonra, tarih ve
saat ayarlanır ve zaman görüntülenir.
5. Tarih ve saati değiştirmek isterseniz, zaman düğmesine basın
ve yıl sayısı yanıp sönünceye kadar 3 saniye basılı tutun. Şimdi
yeni değerleri yukarıda açıklandığı şekilde girebilirsiniz.
Doğru kaf seçimi
Microlife değişik ebatlarda kaflar sunar. Üst kolunuzun çevresine
uygun kaf boyutunu seçin (üst kolunuzun ortasını en uygun şekilde
kavrayarak ölçülür).
Şekil verilmiş «Easy» kaflar opsiyonel olarak mevcuttur,
daha iyi uyum ve konfor için.
Sadece Microlife kaf kullanın!
Ürünle birlikte verilen kaf 6 uymazsa, yerel Microlife Servisi ile
görüşün.
Kaf bağlantısını 7 olabildiğince kaf soketine 3 yerleştirerek,
kafı aygıta bağlayın.
Kullanıcının seçilmesi
Bu cihaz 2 farklı kullanıcı için sonuçları saklamaya izin verir.
Her ölçümden önce hedeflenen kullanıcı için kullanıcı anahta-
rını 9 ayarlayın: kullanıcı 1 veya kullanıcı 2.
Kullanıcı 1: Kullanıcı anahtarını 9 kullanıcı 1' e gelecek şekilde
yukarı doğru çekin.
Kullanıcı 2: Kullanıcı anahtarını 9 kullanıcı 2' ye gelecek
şekilde aşağı doğru çekin.
İlk kullanacak kullanıcı için lütfen kullanıcı 1' i seçin.
Standart veya MAM modunun seçilmesi
Bu aygıt, gerek standart (standart tek ölçüm) gerekse MAM
modunu (otomatik üçlü ölçüm) seçmenizi sağlar. Standart modu
seçmek için, aygıt tarafındaki MAM anahtarını 8 aşağı doğru
konum «1» e getirin ve MAM modunu seçmek için ise, aynı anah-
tarı yukarı doğru konum «3» e getirin.
Uluslararası standartlara (ESH, ESC, JSH) göre yetişkinlerin ev
tansiyon değerlerinin sınıflandırma tablosu. Veriler, mmHg
cinsindendir.
Düzey
Büyük
Tansiyon
Küçük
Tansiyo
neri
1. tansiyon normal < 120 < 74 Kendiniz kontrol
ediniz
2. tansiyon en iyi
aralıkta
120 - 129 74 - 79 Kendiniz kontrol
ediniz
3. tansiyon yükseldi 130 - 134 80 - 84 Kendiniz kontrol
ediniz
4. tansiyon çok
yüksek
135 - 159 85 - 99 Tıbbi kontrolden
geçiniz
5. tansiyon tehlikeli
biçimde yüksek
160 100 Acilen tıbbi
kontrolden
geçiniz!
Kaf boyutu üst kolunuzun çevresi için
S 17 - 22 cm
M 22 - 32 cm
M - L 22 - 42 cm
L 32 - 42 cm
L - XL 32 - 52 cm
43BP A3 Plus
TR
MAM modu (Tavsiye edilen)
MAM modunda, 3 otomatik ardışık ölçüm yapılır ve sonuç
otomatik olarak değerlendirilip görüntülenir. Tansiyon sürekli bir
dalgalı seyir izlediğinden dolayı, bu şekilde alınan ölçüm
sonucu, tek bir ölçüm sonucuna kıyasla daha güvenilirdir.
3-ölçümü seçtiğinizde, MAM sembolü BL ekranda görüntülenir.
Üç ölçümden halihazırda hangisinin yapıldığını göstermek için,
ekranın sağ alt bölümünde 1, 2 ya da 3 rakamı görüntülenir.
Ölçümler arasında 15 saniye aralık bulunmaktadır. Bir geri
sayım kalan zamanı göstermektedir.
Münferit sonuçlar görüntülenmez. Tansiyonunuz, sadece
3 ölçümün hepsi yapıldıktan sonra görüntülenir.
Ölçümler arasında kafı çıkarmayın.
Münferit ölçümlerden birinde sorun yaşanırsa, dördüncü bir
ölçüm otomatik olarak yapılır.
3. Tansiyonun Ölçülmesi
Güvenilir bir ölçüm yapılması için kontrol listesi
1. Ölçümden hemen önce, hareket etmekten kaçının; herhangi bir
şey yemeyin ve sigara içmeyin.
2. Sırt destekli bir sandalyeye oturun ve 5 dakika süre ile bekleyin.
Ayaklarınızı yerde düz bir şekilde konumlandırın, ayak ayak
üstüne atmayınız.
3. Her zaman aynı koldan ölçüm yapın (normalde sol kol).
Doktorlara hastaların ilk ziyaretlerinde gelecekte hangi koldan
ölçüm almaları gerektiğini belirlemek için genellikle iki koldan
birden ölçüm almaları tavsiye edilir. Yüksek kan basıncını veren
kol seçilmelidir.
4. Üst kolunuzu sıkıca kavrayan giysileri çıkarın. Basınç oluştur-
maması için, gömlek kollarını kıvırmayın - düz bırakıldıklarında
kaf işlevini engellemezler.
5.
Her zaman doğru ölçüdeki kafın (ölçü kafın üzerindedir) kullanıl-
dığından emin olun.
Kaf, üst kolunuzu yeterince kavrasın; ancak, çok sıkı olmasın.
Kafın iç dirseğinizin 1-2 cm yukarısına yerleştirildiğinden
emin olun.
Kafın üzerine konumlanmış olan atardamar işareti
(yaklaşık 3 cm uzunluğunda) kolunuzun iç kısmından aşağı
doğru inen atardamarın üzerinde olmalıdır.
Rahatça ölçüm yapılması için, kolunuzu destekleyin.
Kafın kalbinizle aynı yükseklikte olmasını sağlayın.
6. Ölçüm işlemini başlatmak için, AÇ/KAPA düğmesine 1 basın.
7. Kaf şimdi otomatik olarak şişecektır. Gevşeyin; ölçüm sonucu
görüntüleninceye kadar hareket etmeyin ve kol kaslarınızı
kasmayın. Normal biçimde soluk alıp verin ve konuşmayın.
8. Doğru basınca ulaşıldığında, pompalama işlemi durur ve
basınç dereceli olarak düşer. İstenilen basınca ulaşılamamışsa,
aygıt kafa otomatik olarak biraz daha hava pompalar.
9. Ölçüm sırasında nabız göstergesi BT yanıp söner.
10.Büyük tansiyon AO ile küçük tansiyonu AP ve nabzı AQ içeren
sonuç görüntülenir. Broşürdeki diğer görüntülerle ilgili açıkla-
maları da dikkate alı
nız.
11.Ölçüm bittiğinde kafı çıkarınız.
12.Aygıtı kapatın. (Yaklaşık 1 dakika sonra monitör otomatik
olarak kapanır).
Ölçüm sonucu nasıl silinir?
Ölçüm sonucu göründüğü anda, ekranda «M» BO yanıp sönene
kadar AÇ/KAPA tuşuna 1 basılı tutunuz. M tuşuna AT basarak
ölçüm sonucunun silinmesini onaylayınız.
AÇ/KAPA düğmesine basarak, aygıtı istediğiniz zaman
kapatabilirsiniz (örneğin, kendinizi rahat hissetmiyorsanız
ya da rahatsız edici bir basınç algılanması halinde).
Büyük tansiyon çok yüksek ise, basıncı münferit olarak
ayarlamak yararlı olabilir. Pompalamak suretiyle monitör-
deki değer yaklaşık olarak 30 mmHg (ekranda gösterilir)
seviyesine ulaştıktan sonra AÇ/KAPA düğmesine basın.
Basınç, beklenen büyük tansiyon değerinin üzerinden
yaklaşık 40 mmHg daha yükseğe ulaşıncaya kadar
ğmeyi basılı tutun - daha sonra düğmeyi serbest bırakın.
4. Düzensiz Kalp Atışı (IHB) Sembolünün Görünümü
Bu sembol BM düzensiz bir kalp atışının tespit edildiğini gösterir.
Bu durumda, ölçülen kan basıncı gerçek kan basıncı değerleri-
nizden sapabilir. Ölçümü tekrarlamanız önerilir.
5. Ekranda Trafik Işığı Göstergesi
Ekranın sol tarafında AR ki barlar tansiyon değerinin hangi sevi-
yede olduğunu göstermektedir. Barın yüksekliğine bağlı olarak
IHB sembolünün tekrarlı görünmesi durumunda doktor için
bilgi
Bu cihaz, kan basıncı ölçümü sırasında nabzı ölçen ve kalp atış
hızının düzensiz olduğunu gösteren bir osilometrik tansiyon
aletidir.
44
okunan değer; optimum (yeşil), yüksek(sarı), çok yüksek(turuncu)
veya tehlikeli derecede yüksek(kırmızı) olarak değerlendirilir.
Kategoriler, uluslarası standartlar (ESH, ESC, JSH) tablosunda
belirlenmiş olan 4 aralığı belirtmektedir «Bölüm 1.».
6. Veri Belleği
Bu cihaz otomatik olarak 2 kullanıcı için ayrı ayrı 99 kayıt yapabil-
mektedir.
Kaydedilen değerlerin görüntülenmesi
Kullanıcı anahtarı 9 ile kullanıcı 1 veya 2'yi seçin.
Aygıt kapanınca M-düğmesine AT kısaca basın. Ekranda, önce
«M» BO simgesi ve «A» tüm saklı değerlerin ortalamasını gösterir.
M-düğmesine tekrar basıldığında, bir önceki değer görüntülenir.
M-düğmesine üst üste basarak, bir kayıtlı değerden diğerine geçe-
bilirsiniz.
Bellek dolu
Her kullanıcı için 99 ölçüm sonucunu içeren hafıza kapasi-
tesinin aşılmamasına dikkat ediniz. 99 ölçümlük hafıza
dolduğunda, 100. ölçüm en eski ölçüm verisi silinerek
kaydedilir. Sonuçlar, maksimum hafıza kapasitesine eriş-
meden doktor tarafından incelenmelidir, aksi takdirde
veriler kaybolur.
Tüm değerlerin silinmesi
Doğru kullanıcının seçili olduğundan emin olun.
1. Cihaz kapalıyken, kullanıcı anahtarı 9 1 veya 2 konumuna
getirin.
2. M-düğmesine AT ekranda «CL» ibaresi görünene kadar basılı
tutun ve göründüğünde düğmeye basmayı bırakın.
3. «CL» ibaresi yanıp sönerken M-düğmesine basın. Böylelikle
seçili kullanıcının tüm verileri kalıcı olarak silinmiş olur.
Silme İptali: ibaresi ekrandayken AÇ/KAPA düğmesine 1
basın.
Münferit değerler, silinemez.
7. Pil Göstergesi ve Pil değişimi
Piller neredeyse bitmiş
Piller, yaklaşık olarak ¾ oranında kullanıldığında, aygıt açılır
ılmaz kullanılmış pil simgesi AM yanıp söner (kısmen dolu bir pil
görüntülenir). Her ne kadar aygıt, güvenilir ölçüm yapmaya devam
etse de pilleri değiştirmeniz gerekir.
Piller bitmiş – pillerin değiştirilmesi
Piller bittiğinde, aygıt açılır açılmaz pil simgesi AM yanıp söner
(bitmiş bir pil görüntülenir). Piller bitttiğinde, artık ölçüm yapamaz-
sınız ve pilleri değiştirmeniz gerekir.
1. Aygıtın altındaki pil bölmesini 4ın.
2. Pilleri değiştirin – bölmedeki simgelerle gösterildiği şekilde
kutupların doğru konumda olup olmadığına dikkat edin.
3. Tarih ve saati ayarlamak için, «Bölüm 2.» de açıklanan yöntemi
uygulayın.
Tarih ve saatin sıfırlanması gerekmesine karşın, bellek tüm
değerleri korur – bu nedenle, piller değiştirildikten sonra, yıl
sayısı otomatik olarak yanıp söner.
Hangi piller ve yöntem?
Lütfen, 4 adet yeni ve uzun ömürlü 1.5V, AA alkalin pili
kullanın.
Kullanım süresi geçen pilleri kullanmayın.
Aygıt uzun bir süre kullanılmayacaksa, pilleri çıkarın.
Şarj edilebilir pillerin kullanılması
Aygıtı şarj edilebilir pilleri kullanarak da çalıştırabilirsiniz.
Lütfen, sadece «NiMH» türünde yeniden kullanılabilir pilleri
kullanın!
Pil simgesi (bitmiş pil) görüntülendiğinde, pillerin çıkarılıp
şarj edilmesi gerekmektedir! Zarar görebileceklerinden,
pillerin aygıtın içerisinde bırakılmaması gerekmektedir
(kapalı olsa bile aygıtın düşük kullanımının bir sonucu
olarak tamamen boşalırlar).
Bir hafta ya da daha uzun bir süre kullanmayışünmüyor-
sanız, her zaman şarj edilebilir pilleri çıkarın!
Piller, tansiyon ölçüm aletinde şarj EDİLEMEZ! Bu pilleri
harici bir şarj aygıtında şarj edin; bununla birlikte, şarj,
bakım ve dayanıklılık konusundaki bilgileri dikkate alın!
8. Elektrik Adaptörünün Kullanılması
Bu aygıtı Microlife elektrik adaptörü kullanarak da çalıştırabilirsiniz
(DC 6V, 600 mA).
Elektrik geriliminiz için mevcut olan uygun orijinal aksesuar
olarak sadece Microlife elektrik adaptörü kullanın.
Elektrik adaptörünün ya da kablonun zarar görmediğinden
emin olun.
1. Adaptör kablosunu, tansiyon ölçüm aletinin elektrik adaptör
soketine 5 takın.
45BP A3 Plus
TR
2. Adaptör fişini duvar prizine takın.
Elektrik adaptörü bağlandığında, artık pil enerjisi kullanılmaz.
9. Hata İletileri
Ölçüm sırasında hata meydana gelirse, ölçüm işlemi durdurulur ve
bir hata iletisi, örneğin «ERR 3», görüntülenir.
* Bu veya başka bir problem tekrarlar ise, lütfen acilen doktoru-
nuza başvurunuz.
Sonuçların anormal olduğunu düşünüyorsanız, lütfen,
«Bölüm 1.» deki bilgileri dikkatli biçimde okuyun.
10.Güvenlik, Bakım, Doğruluk Testi ve Elden Çıkarma
Güvenlik ve koruma
Kullanım için talimatları okuyunuz. Bu doküman cihazın güvenli
kullanımı için önemli bilgiler içermektedir. Lütfen cihazı kullan-
madan önce bu dökümanı tamamen okuyunuz ve gelecekte
tekrar başvurmak üzere saklayınız.
Bu ürün, sadece bu broşürde açıklanan amaçlar çerçevesinde
kullanılabilir. İmalatçı, yanlış uygulamadan kaynaklanan zarar
ziyan için sorumlu tutulamaz.
Aygıt, hassas parçalara sahiptir ve dikkatli biçimde kullanılmalıdır.
«Teknik Özellikler» bölümünde açıklanan saklama ve çalıştırma
koşullarını göz önünde bulundurun!
Aşağıdaki durumlara maruz kalmasına engel olun:
- su ve nem
-aşırı sıcaklıklar
- darbe ve düşürülme
- kir ve toz
-doğrudan güneş ışığı
-sıcak ve soğuk
Kaf, hassastır ve dikkatli biçimde kullanılmalıdır.
Bu cihaz ile ölçüm yaparken başka çeşit kaf veya kaf konnektörü
kullanmayınız ya da değiştirmeyiniz.
Kafı cihaza taktıktan sonra pompalayın.
Aygıtı cep telefonları ya da radyo donanımları gibi güçlü elektro-
manyetik alanlara yakın yerlerde kullanmayın. Aygıtı kullanırken
bu tip cihazlardan minimum 3.3 metre uzakta olun.
Hasar gördüğünü düşünüyorsanız ya da herhangi bir anormal
durum sezdiyseniz, aygıtı kullanmayın.
Aygıtı kesinlikle açmayın.
Aygıtın uzun bir süre kullanılmaması durumunda, pillerin çıkarıl-
ması gerekir.
Broşürün ilgili bölümlerindeki diğer güvenlik talimatlarını da okuyun.
Bu cihaz tarafından verilen ölçüm sonuçları bir teşhis olarak
değerlendirilmemelidir. Mutlaka doktorunuza danışınız. Özellikle,
hasta semptomları cihaz ölçümüyle uyuşmuyorsa sadce ölçüm
sonucuna güvenmeyin. Diğer semptomları ve hastanın geri bildi-
rimini göz önünde bulundurarak doktorunuzla görüşün veya gere-
kiyorsa ambulans çağırın.
Çocukların denetimsiz bir şekilde ürünü kullanmalarına izin
vermeyin; bazı parçalar, yutulabilecek kadar küçüktür.
Aygıtın kablo veya borularının olması nedeni ile yaratabile-
ceği boğulma riskinin farkında olun.
Hata ıklama Olası nedeni ve çözümü
«ERR 1» Sinyal çok
zayıf
Kaf nabız sinyalleri çok zayıf. Kafı
yeniden takın ve ölçümü tekrarlayın.*
«ERR 2»
BN
Hata sinyali Ölçüm sırasında, kaf, hareket etmekten
ya da adale kasılmasından kaynaklanan
hata sinyalleri algıladı. Kolunuzu kımıl-
datmadan ölçümü tekrarlayın.
«ERR 3»
BK
Kafta
basınç yok
Kaf uygun basınç oluşturulamıyor.
Kaçak meydana gelmiş olabilir. Kafın
doğru takı
lıp takılmadığını ve çok gevşek
olup olmadığını konrol edin. Gerekirse,
pilleri değiştirin. Ölçümü tekrarlayın.
«ERR 5»Anormal
sonuç
Ölçüm sinyalleri doğru değil ve bu
nedenle sonuç görüntülenemiyor. Güve-
nilir ölçüm yapılabilmesi için, kontrol
listesini okuyun ve ölçümü tekrarlayın.*
«ERR 6» MAM Modu MAM modunda ölçüm yapılırken, nihai
sonucun alınmasını imkansız kılan
birçok hata oluştu. Güvenilir ölçüm yapı-
labilmesi için, kontrol listesini okuyun ve
ölçümü tekrarlayın.*
«HI»Nabız ya da
kaf basıncı
çok yüksek
Kaf basınç çok yüksek (299 mmHg'nin
üzerinde) YA DA nabız çok yüksek (daki-
kada 200 atıştan fazla). 5 dakika
gevşeyin ve ölçümü tekrarlayın.*
«LO»Nabız çok
ş
ük
Nabız çok düşük (dakikada 40 atıştan
daha düşük). Ölçümü tekrarlayın.*
46
Aygıtın bakımı
Aygıtı sadece yumuşak ve kuru bir bezle temizleyin.
Kafın temizlenmesi
Kaf üzerindeki noktaları sabunlu su ile nemlendirilmiş bezle dikkatli
bir şekilde gideriniz.
UYARI: Kafı çamaşır veya bulaşık makinesinde yıkama-
yınız!
Doğruluk testi
Her 2 yılda bir ya da mekanik darbeye maruz kalması (örneğin,
şürülmesi) durumunda, ürünün doğru çalışıp çalışmadığının
test edilmesini öneririz. Test işlemini ayarlamak için, lütfen, yerel
Microlife-Servisi ile görüşün (bkz ön söz).
Elden çıkarma
Piller ve elektronik ürünler, çöpe atılmamalı; ancak, yürür-
lükteki yönetmeliklere uygun olarak elden çıkarılmalıdır.
11.Garanti Kapsamı
Bu aygıt, satın alındığı tarihten itibaren 5 yıl garanti kapsamın-
dadır. Bu garanti süresi içinde, bizim takdirimize bağlı olarak,
Microlife arızalı ürünü ücretsiz olarak onaracak veya değiştire-
cektir.
Aygıtın açılması ya da üzerinde değişiklik yapılması, garantiyi
geçersiz kılar.
Aşağıdaki öğeler garanti kapsamı dışındadır:
Nakliye maliyetleri ve nakliye riskleri.
Yanlış uygulamadan veya kullanım talimatlarına uyulmama-
sından kaynaklanan hasar.
Sızdıran pillerden kaynaklanan hasar.
Kaza veya yanlış kullanımdan kaynaklanan hasar.
Ambalaj / depolama malzemesi ve kullanım talimatları
.
Düzenli kontroller ve bakım (kalibrasyon).
Aksesuarlar ve aşınan parçalar: Piller, güç adaptörü (isteğe
bağlı).
Kaf 2 yıl boyunca fonksiyonel bir garanti (hava kesesinin sıkılığı)
kapsamındadır.
Garanti servisinin gerekli olması halinde, lütfen ürünün satın alın-
dığı bayiye veya yerel Microlife servisinize başvurun. Yerel Micro-
life hizmetinize web sitemizden ulaşabilirsiniz:
www.microlife.com/support
Tazminat ürünün değeri ile sınırlıdır. Tüm ürün orijinal fatura ile
birlikte iade edilirse garanti verilecektir. Garanti kapsamındaki
onarım veya değiştirme, garanti süresini uzatmaz veya yenilemez.
Tüketicilerin yasal talepleri ve hakları bu garanti ile sınırlı değildir.
12.Teknik Özellikler
Bu cihaz, 93/42/EEC Tıbbi Cihaz Yönetmenliği gereksinimleri ile
uyumludur.
Teknik özelliklerin değiştirilmesi hakkı saklıdır.
Çalışma koşulları: 10 - 40 °C / 50 - 104 °F
%15 - 95 maksimum bağıl nem
Saklama koşulları: -20 - +55 °C / -4 - +131 °F
%15 - 95 maksimum bağıl nem
Ağırlık: 368 g (piller dahil)
Boyutlar: 143 x 85 x 58 mm
Ölçüm yöntemi: osilometrik, Korotkoff yöntemine uygun:
Aşama I büyük tansiyon, Aşama V küçük
tansiyon
Ölçüm aralığı: 20 - 280 mmHg – tansiyon
dakikada 40 - 200 atış – nabız
Kaf basıncı görüntü-
leme aralığı: 0 - 299 mmHg
Çözünürlük: 1 mmHg
Statik doğruluk: ±3 mmHg aralığında bası
Nabız doğruluğu: ±ölçülen değerin %5'i
Gerilim kaynağı:
4 x 1.5 V alkalin piller; boyut AA
Elektrik adaptörü DC 6V, 600 mA (isteğe
bağlı)
Pil ömrü: Yaklaşık 920 ölçüm (Yeni pillerle)
IP sınıfı: IP20
İlgili standartlar: EN 1060-1 /-3 /-4; IEC 60601-1;
IEC 60601-1-2 (EMC); IEC 60601-1-11
Beklenen servis
ömrü:
Cihaz: 5 yıl veya 10000 ölçüm
Aksesuarlar: 2 yıl
47BP A3 Plus
TR
48
Visor
Leia atentamente este manual de instruções antes de
utilizar o dispositivo.
Peça aplicada tipo BF
Uso pretendido:
Este tensiómetro oscilométrico destina-se a medir tensão arterial
não invasiva em pessoas com 12 anos ou mais.
É clinicamente testado em pacientes com hipertensão, hipo-
tensão, diabetes, gravidez, pré-eclâmpsia, aterosclerose, doença
renal em fase terminal, obesidade e idosos.
Estimado cliente,
Este dispositivo foi desenvolvido com a colaboração de peritos na
área da medicina e os ensaios clínicos realizados comprovam a
sua elevada precisão na medição.*
Se tiver alguma questão, problema ou se pretender encomendar
peças sobresselentes, não hesite em contactar o seu distribuidor
local da Microlife. A farmácia da sua zona poderá indicar a morada
do distribuidor Microlife no seu país. Pode também visitar o site
www.microlife.com onde encontrará toda a informação útil sobre
os produtos Microlife.
Mantenha-se saudável – Microlife AG!
* Este dispositivo utiliza a mesma tecnologia de medição utilizada
no modelo «BP 3BTO-A» já premiado, sendo um modelo testado
em conformidade com o protocolo BIHS (British and Irish Hyper-
tension Society).
Microlife BP A3 Plus
PT
1
Botão ON/OFF
2
Visor
3
Entrada da braçadeira
4
Compartimento das pilhas
5
Entrada do adaptador
6
Braçadeira
7
Conector da braçadeira
8
Interruptor MAM
9
Botão de utilizador
AT
Botão M (Memória)
AK
Botão das horas
AL
Indicador do utilizador
AM
Visualização das pilhas
AN
Data/Hora
AO
Pressão sistólica
AP
Pressão diastólica
AQ
Frequência cardíaca
AR
Indicador luminoso do nível da pressão arterial
AS
Intervalo de tempo MAM
BT
Indicador da pulsação
BK
Indicador da braçadeira
BL
Modo MAM
BM
Símbolo de batimento cardíaco irregular (IHB)
BN
Indicador do movimento do braço
BO
Valor guardado
Manter seco
49BP A3 Plus
PT
Índice
1. Aspetos importantes sobre a pressão arterial e a auto-
medição
Como avaliar a minha pressão arterial?
2. Utilizar o dispositivo pela primeira vez
Inserir as pilhas
Definir a data e hora
Escolher a braçadeira adequada
Selecção do utilizador
Selecionar o modo standard (padrão) ou modo MAM
Modo MAM (altamente recomendado)
3. Medir a pressão arterial
Como não guardar um resultado
4. Visualização do símbolo de batimento cardíaco irregular
(IHB)
5. Mostrador com indicador luminoso do nível da pressão
arterial (sistema «semáforo»)
6. Memorização de dados
Visualizar valores guardados
Memória cheia
Limpar todos os valores
7. Indicador de carga e substituição de pilhas
Pilhas quase descarregadas
Pilhas descarregadas – substituição
Quais as pilhas a utilizar e quais os procedimentos a
efetuar?
Utilizar pilhas recarregáveis
8. Utilizar um adaptador
9. Mensagens de erro
10. Segurança, cuidados, teste de precisão e eliminação de
resíduos
Segurança e proteção
Cuidados a ter com o dispositivo
Limpeza da braçadeira
Teste de precisão
Eliminação de resíduos
11. Garantia
12. Especificações técnicas
Cartão de garantia (ver contracapa)
1. Aspetos importantes sobre a pressão arterial e a
auto-medição
A pressão arterial é a pressão da circulação sanguínea nas
artérias gerada pelos batimentos cardíacos. É sempre
efetuada a medição de dois valores, o valor máximo pressão
arterial sistólica e o valor mínimo pressão arterial diastólica.
Este aparelho também indica a frequência cardíaca (ou seja,
o número de batimentos cardíacos por minuto).
Valores de pressão arterial constantemente elevados
podem prejudicar a saúde e têm de ser acompanhados
pelo seu médico!
Indique sempre os valores das medições obtidos ao seu
médico e informe-o se detectar qualquer irregularidade ou em
caso de dúvida. Nunca confie numa leitura de pressão arte-
rial isolada.
Existem diversas causas para valores de tensão arterial
demasiado elevados. O seu médico poderá explicá-las mais
detalhadamente e propor o respectivo tratamento, se neces-
sário. Para além da medicação, a perda de peso e o exercício
físico podem também contribuir para diminuir a tensão arterial.
Em nenhuma circunstância deve alterar as dosagens dos
fármacos ou iniciar um tratamento sem consultar o seu médico.
Dependendo das condições físicas e do esforço físico, a
tensão arterial está sujeita a grandes flutuações com o decorrer
do dia. Deste modo, deverá efectuar sempre as medições
num ambiente calmo quando estiver descontraído! Faça
sempre pelo menos duas medições (de manhã e à noite), e
faça a média das leituras.
É perfeitamente normal que duas medições efectuadas suces-
sivamente apresentem resultados significativamente dife-
rentes. Recomenda-se portanto o uso da tecnologia MAM.
As diferenças de valores verifiadas entre as medições efetu-
adas pelo médico ou realizadas na farmácia e as medições
efetuadas em casa são perfeitamente normais, uma vez que
estas situações são completamente diferentes.
Diversas medições dão resultados mais fiáveis da pressão
arterial do que uma única medição. Recomenda-se portanto o
uso da tecnologia MAM.
Faça um pequeno intervalo de, pelo menos, 15 segundos
entre duas medições.
Se sofre de arritmia cardíaca, consulte o seu médico antes de
usar o dispositivo. Consulte também o capítulo «Visualização
50
do símbolo de batimento cardíaco irregular (IHB)» neste
manual do utilizador.
A visualização da pulsação não se aplica no controlo da
frequência dos «pacemakers»!
Se estiver grávida, deve avaliar a sua tensão arterial regular-
mente, pois pode mudar drasticamente durante este tempo.
Este tensiómetro é especialmente testado para utilização
durante a gravidez e pré-eclâmpsia. Quando são detetadas
leituras elevadas e irregulares durante a gravidez, passado
algum tempo deve repetir a medição (por exemplo, 1 hora).
Se a leitura permanecer muito alta, consulte o seu médico
ou ginecologista.
Como avaliar a minha pressão arterial?
O valor mais elevado é o valor que determina o resultado da
análise Exemplo: uma leitura de 140/80 mmHg ou 130/90 mmHg
indica «tensão arterial muito alta».
2. Utilizar o dispositivo pela primeira vez
Inserir as pilhas
Após ter desempacotado o dispositivo, comece por inserir as pilhas.
O compartimento das pilhas
4
está localizado na parte inferior do
dispositivo. Insira as pilhas (4 x 1,5 V pilhas, tamanho AA) e respeite
a polaridade indicada.
Definir a data e hora
1. Quando as novas pilhas estiverem colocadas, aparecerá no
mostrador um número a piscar que corresponde ao ano. Pode definir
o ano pressionando o botão M
AT
. Para efetuar a confirmação e, em
seguida, definir o mês, pressione o botão das horas
AK
.
2. Pode agora definir o mês utilizando o botão M. Pressione o botão
das horas para efetuar a confirmação e, em seguida, defina o dia.
3. Siga as instruções acima para definir o dia, as horas e os minutos.
4. Quando tiver definido os minutos e pressionado o botão das
horas, a data e hora são definidas e aparece a indicação da hora.
5. Se pretender alterar a data e hora, pressione e mantenha pressio-
nado o botão das horas durante aproximadamente 3 segundos
até que o número correspondente ao ano comece a piscar. Agora
pode introduzir os novos valores, conforme descrito acima.
Escolher a braçadeira adequada
A Microlife tem disponíveis diversos tamanhos de braçadeira.
Escolha o tamanho de braçadeira adequado à circunferência da
parte superior do braço (que deve ser medida com a braçadeira
ajustada no meio da parte superior do braço).
Braçadeiras rígidas «Easy» estão disponíveis como aces-
sório opcional para uma melhor adaptação ao braço e
maior conforto na medição.
Utilize apenas braçadeiras da Microlife!
Contacte o seu local Assistência da Microlife, caso a braçadeira
fornecida 6 não seja adequada.
Ligue a braçadeira ao aparelho introduzindo completamente o
conector da braçadeira 7 na respectiva entrada 3.
Selecção do utilizador
Este dispositivo guarda os resultados de 2 utilizadores individuais.
Antes de cada medição marque o botão 9 para o utilizador
que pretende: 1 ou 2.
Utilizador 1: desloque o botão do utilizador 9 para cima até ao
símbolo do utilizador 1.
Quadro de classificação da tensão arterial medida em casa em
adultos de acordo com as directrizes internacionais da (ESH,
ESC, JSH). Valores em mmHg.
Nível Sistólica
Diastó-
lica Recomendações
1. pressão arterial
normal
< 120 < 74 Auto-medição
2. pressão arterial
ideal
120 - 129 74 - 79 Auto-medição
3. tensão arterial
elevada
130 - 134 80 - 84 Auto-medição
4. pressão arterial
muito alta
135 - 159 85 - 99 Obtenha aconse-
lhamento médico
5. tensão arterial
extremamente alta
com gravidade
160 100 Consulte o médico
com urgência!
Tamanho da
braçadeira
para uma circunferência da parte superior do
braço
S 17 - 22 cm
M 22 - 32 cm
M - L 22 - 42 cm
L 32 - 42 cm
L - XL 32 - 52 cm
51BP A3 Plus
PT
Utilizador 2: desloque o botão do utilizador 9 para baixo até
ao símbolo do utilizador 2.
A primeira pessoa a medir deve seleccionar o utilizador 1.
Selecionar o modo standard (padrão) ou modo MAM
Este aparelho permite optar entre o modo padrão (uma única
medição padrão) e o modo MAM (medição tripla automática). Para
seleccionar o modo padrão, faça deslizar para baixo o interruptor
MAM 8 situado na parte lateral do aparelho, na direcção da
posição «1» e para seleccionar o modo MAM, faça deslizar este
interruptor para cima, em direcção à posição «3».
Modo MAM (altamente recomendado)
No modo MAM, são efectuadas automaticamente 3 medições
consecutivas e, em seguida, o resultado é automaticamente
analisado e apresentado. Uma vez que a tensão arterial está
constantemente a sofrer variações, um resultado determinado
utilizando este método é mais fiável do que um resultado obtido
através de uma única medição.
Quando escolhe as 3 medições, o símbolo MAM BL aparece no
mostrador.
No canto inferior direito do mostrador aparece 1, 2 ou 3 para
indicar qual das 3 medições está actualmente a ser efectuada.
Existe uma pausa de 15 segundos entre as medições. Uma
contagem decrescente indica o tempo restante.
Os resultados individuais não são apresentados. A tensão arte-
rial apenas será apresentada após terem sido efectuadas as
3 medições.
Não retire a braçadeira no período entre as medições.
Se uma das medições individuais suscitar dúvidas, será auto-
maticamente efectuada uma quarta medição.
3. Medir a pressão arterial
Check-list para efetuar uma medição correta
1. Não deve comer, fumar nem exercer qualquer tipo de esforço
físico imediatamente antes de efetuar a medição.
2. Sente-se numa cadeira apoiada nas costas e relaxe por 5
minutos. Mantenha os pés no chão e não cruze as pernas.
3. Deve efectuar a medição sempre no mesmo braço (normal-
mente o braço esquerdo). O médico deve efectuar as medições
em ambos os braços do doente na primeira consulta para
determinar qual o braço a utilizar de futuro. A medição deve ser
efectuada no braço com a leitura mais elevada.
4. Retire qualquer peça de vestuário que possa estar justa na
parte superior do braço. Para evitar que seja exercida pressão,
as mangas da camisa não devem estar enroladas para cima,
uma vez que não interferem com a braçadeira se estiverem
esticadas normalmente.
5. Assegure-se sempre de que está a usar uma braçadeira de
tamanho correcto (indicado na braçadeira).
Ajuste bem a braçadeira, mas não aperte demasiado.
A braçadeira deverá estar colocada 1-2 cms acima do seu
cotovelo.
A marca da artéria na braçadeira (barra com aproximada-
mente 3 cm), deve ser colocada sobre a artéria localizada
no lado interior do braço.
Coloque o braço assente numa superfície, para que fique
descontraído.
Certifique-se de que a braçadeira fica à mesma altura do
coração.
6. Pressione o botão ON/OFF 1 para iniciar a medição.
7. A braçadeira começa a encher-se automaticamente. Descon-
traia, não se mova e não contraia os músculos do braço
enquanto o resultado da medição não for apresentado. Respire
normalmente e não fale.
8. Quando a pressão correta for atingida, a braçadeira deixa de
encher e a pressão desce gradualmente. Caso a pressão
necessária não tenha sido atingida, o aparelho introduz auto-
maticamente mais ar na braçadeira.
9. Durante a medição o indicador da pulsação
BT
aparece a piscar
no visor.
10.O resultado da pressão sistólica AO e diastólica AP bem como
a pulsação AQ aparecem no visor. Consulte também as infor-
mações contidas neste livro sobre os outros símbolos.
11.Remova a braçadeira após efectuar a medição.
12.Desligue o aparelho. (O monitor desliga-se automaticamente
decorrido cerca de 1 min.)
Como não guardar um resultado
Quando o resultado aparecer no visor, mantenha a pressão no
botão ON/OFF 1 até «M» BO começar a piscar. Confirme a
anulação da leitura premindo o botão M AT.
É possível interromper a medição em qualquer altura pres-
sionando o botão ON/OFF (por exemplo, se sentir-se inco-
modado ou desconfortável com a sensação de pressão).
52
Se a tensão arterial sistólica costuma ser muito elevada
,
poderá constituir uma vantagem definir a pressão individual-
mente. Pressione o botão ON/OFF após o valor no monitor
ter aumentado até um nível correspondente a aproximada-
mente 30 mmHg (visível no mostrador). Mantenha o botão
pressionado até a pressão atingir cerca de 40 mmHg acima
do valor sistólico esperado e, em seguida, solte o botão.
4. Visualização do símbolo de batimento cardíaco
irregular (IHB)
Este símbolo BM indica que um batimento cardíaco irregular foi
detetado. Nesse caso, a tensão arterial medida pode divergir dos
valores reais da tensão arterial. É recomendável repetir a
medição.
5. Mostrador com indicador luminoso do nível da
pressão arterial (sistema «semáforo»)
As barras localizadas no lado esquerdo do mostrador
AR
indicam o
limite dos valores obtidos. Dependendo da altura da barra, os valores
classificam-se por óptimos (verde), elevados (amarelo), demasiado
elevados (laranja), ou perigosos (vermelho). A classificação corres-
ponde aos 4 limites na escala tal como definidos pelas directrizes
internacionais (
ESH, ESC, JSH
), como descrito na «Secção 1.».
6. Memorização de dados
Este dispositivo guarda automaticamente até 99 valores de
medição para cada um dos 2 utilizadores.
Visualizar valores guardados
Selecione utilizador 1 ou 2 com o botão do utilizador
9
.
Pressione o botão M
AT
durante breves instantes, quando o disposi-
tivo estiver desligado. Primeiro o dispositivo apresenta o símbolo «
M
»
BO
e «
A
», que representa a média de todos os valores armazenados.
Se pressionar novamente o botão M, será apresentado o valor
anterior. Pressionando o botão M várias vezes é possível alternar
entre os valores guardados.
Memória cheia
Assegure-se de que não ultrapassa as 99 memórias por
utilizador. Quando as 99 memórias estão cheias, o valor
mais antigo é automaticamente substituído pelo valor
da 100ª medição. Os valores deverão ser analisados por
um médico antes de ser atingida a capacidade da memória,
caso contrário os dados perder-se-ão.
Limpar todos os valores
Certifique-se que o utilizador correto está activado.
1. Seleccione o utilizador 1 ou 2 com o botão do utilizador 9, com
o dispositivo desligado.
2. Prima o botão M AT até aparecer «CL» e solte o botão.
3. Prima o botão M enquanto «
CL
» permanece a piscar para limpar
permanentemente todos os valores do utilizador seleccionado.
Anular a acção: prima o botão ON/OFF 1 enquanto «CL»
permanece a piscar.
Não é possível apagar valores individualmente.
7. Indicador de carga e substituição de pilhas
Pilhas quase descarregadas
Quando tiverem sido utilizados cerca de ¾ da carga das pilhas, o
símbolo de pilha AM será apresentado a piscar, ao ligar o aparelho
(é apresentada uma pilha parcialmente preenchida). Ainda que a
precisão de medição do aparelho não seja afetada, deverá
adquirir pilhas para a respetiva substituição.
Pilhas descarregadas – substituição
Quando as pilhas estiverem descarregadas, o símbolo de pilha AM
será apresentado a piscar, ao ligar o aparelho (é apresentada uma
pilha descarregada). Não é possível efetuar medições e é neces-
sário substituir as pilhas.
1. Abra o compartimento das pilhas 4, situado na parte inferior
do aparelho.
2. Substitua as pilhas – verifique a polaridade correta, conforme
indicado pelos símbolos existentes no compartimento.
3. Para definir a data e hora, siga o procedimento descrito na
«Secção 2.».
A memória guarda todos os valores, ainda que a data e
hora tenham de ser repostas – deste modo, o número
correspondente ao ano é automaticamente apresentado a
piscar, quando as pilhas forem substituídas.
Informação para o seu médico em caso de visualização
repetida do símbolo IHB
Este dispositivo é um tensiómetro oscilométrico que também
realiza a medição da pulsação durante a medição da tensão
arterial, e indica quando a frequência cardíaca está irregular.
53BP A3 Plus
PT
Quais as pilhas a utilizar e quais os procedimentos a efetuar?
Utilize 4 pilhas alcalinas AA novas, de longa duração, com
1,5 V.
Não utilize pilhas cujo prazo de validade tenha sido excedido.
Se o aparelho não for utilizado durante um longo período
de tempo, deverá retirar as pilhas.
Utilizar pilhas recarregáveis
Este aparelho também funciona com pilhas recarregáveis.
Utilize apenas pilhas recarregáveis do tipo «NiMH»!
Caso seja apresentado o símbolo de pilha (pilha descarre-
gada), é necessário substituir e recarregar as pilhas! Não
deixe as pilhas no interior do aparelho, uma vez que podem
ficar danificadas (pode verificar-se descarga total como
resultado de uma utilização pouco frequente do aparelho,
mesmo quando desligado).
Caso não tencione utilizar o aparelho durante um período
igual ou superior a uma semana, retire sempre as pilhas
recarregáveis do mesmo!
NÃO é possível carregar as pilhas no monitor de pressão
arterial! Recarregue este tipo de pilhas utilizando um carre-
gador externo e tenha em atenção as informações respei-
tantes ao carregamento, cuidados e duração!
8. Utilizar um adaptador
Este aparelho pode funcionar com um adaptador da Microlife
(DC 6V, 600 mA).
Utilize apenas o adaptador da Microlife disponibilizado
como acessório original com a voltagem adequada.
Certifique-se de que o adaptador e o cabo não se encontram
danificados.
1. Ligue o cabo do adaptador à entrada do adaptador 5 no
monitor de tensão arterial.
2. Ligue a ficha do adaptador à tomada.
Quando o adaptador estiver ligado, não se verifica o consumo da
carga das pilhas.
9. Mensagens de erro
Se ocorrer um erro durante a medição, esta é interrompida, sendo
apresentada uma mensagem de erro, por exemplo, «ERR 3».
* Por favor, consulte imediatamente o seu médico, se este ou
qualquer outro problema ocorrer repetidamente.
Se considerar os resultados invulgares, leia cuidadosamente
as informações descritas na «Secção 1.».
Erro Descrição Causa possível e solução
«ERR 1» Sinal
demasiado
fraco
Os sinais da pulsação na braçadeira são
demasiado fracos. Coloque novamente a
braçadeira e repita a medição.*
«ERR 2»
BN
Sinal de
erro
Durante a medição, a braçadeira
detectou sinais de erro causados, por
exemplo, por movimentos ou pela
contração dos músculos. Repita a
medição, mantendo o braço imóvel.
«ERR 3»
BK
Braçadeira
sem
pressão
Não é possível introduzir pressão suficiente
na braçadeira. Poderá ter ocorrido uma
fuga. Verifique se a braçadeira está correta-
mente ligada e bem ajustada. Substitua as
pilhas se necessário. Repita a medição.
«ERR 5» Resul-
tados
imprecisos
Os sinais da medição não são exatos,
pelo que não é possível apresentar qual-
quer resultado. Consulte a Check-list
para efetuar medições corretas e, em
seguida, repita a medição.*
«HI» Pressão da
braçadeira
ou
pulsação
demasiado
elevada
A pressão da braçadeira é demasiado
elevada (superior a 299 mmHg) OU a
pulsação é demasiado elevada (mais de
200 batimentos por minuto). Descontraia
durante 5 minutos e repita a medição.*
«LO» Pulsação
demasiado
baixa
A pulsação está demasiado baixa (infe-
rior a 40 batimentos por minuto). Repita a
medição.*
54
10. Segurança, cuidados, teste de precisão e eliminação
de resíduos
Segurança e proteção
Siga as instruções de uso. Este documento fornece informações
importantes de manuseamento e segurança do produto em
relação a este dispositivo. Leia atentamente este documento
antes de usar o dispositivo e guarde-o para referência futura.
Este dispositivo deve somente ser utilizado para os fins
descritos neste folheto. O fabricante não se responsabiliza por
quaisquer danos causados pelo uso indevido deste dispositivo.
O dispositivo é composto por componentes sensíveis e deve ser
manuseado com cuidado. Respeite as indicações de acondicio-
namento e funcionamento descritas na secção «Especificações
técnicas»!
Proteja o dispositivo de:
- Água e humidade
- Temperaturas extremas
- Impactos e quedas
- Contaminação e poeiras
- Luz direta do sol
- Calor e frio
As braçadeiras são sensíveis e têm de ser manuseadas com
cuidado.
O dispositivo só pode ser utilizado com braçadeiras ou peças
de ligação da Microlife.
Encha a braçadeira apenas depois de bem ajustada.
Não utilize o dispositivo na proximidade de campos electromag-
néticos fortes, tais como, telemóveis ou instalações radiofónicas.
Manter uma distância mínima de 3,3 m a partir dos dispositivos
mencionados quando se utiliza este dispositivo.
Não utilize este dispositivo se estiver danificado ou se detectar
qualquer anomalia.
Nunca abra o dispositivo.
Se o dispositivo não for utilizado durante um longo período de
tempo, deverá retirar as pilhas.
Consulte também as informações de segurança incluídas nas
secções individuais deste manual.
O resultado da medição fornecido por este dispositivo não é um
diagnóstico. Não substitui a necessidade de consulta com o
seu médico, particularmente caso os sintomas do paciente não
correspondam ao real. Não confie apenas no resultado da
medição, considere sempre outras possibilidades, possíveis
sintomas e comentários do paciente. Ligar para o médico ou
chamar uma ambulância é aconselhada, caso necessário.
Certifique-se de que não deixa o dispositivo ao alcance das
crianças, algumas peças são muito pequenas e podem ser
engolidas. Esteja atento ao risco de estrangulamento no
caso deste dispositivo ser fornecido com cabos ou tubos.
Cuidados a ter com o dispositivo
Para efetuar a limpeza do dispositivo, utilize apenas um pano
macio e seco.
Limpeza da braçadeira
Limpe a braçadeira cuidadosamente com um pano húmido e
espuma de sabão.
AVISO: Não lave a braçadeira na máquina de lavar roupa
ou loiça!
Teste de precisão
Recomendamos a realização de testes de precisão ao dispositivo
de 2 em 2 anos ou após impacto mecânico (por exemplo, após
uma queda). Contacte o seu local Assistência da Microlife para
providenciar o teste (ver mais adiante).
Eliminação de resíduos
As pilhas e dispositivos eletrónicos têm de ser eliminados
em conformidade com os regulamentos locais aplicáveis,
uma vez que não são considerados resíduos domésticos.
11.Garantia
Este dispositivo está abrangido por uma garantia de 5 anos a
partir da data de compra. Durante este momento de garantia, ao
seu critério, o reperesentante da Microlife trocará o seu produto
defeituoso, sem qualquer custo.
A garantia não é válida se o dispositivo for aberto ou alterado.
Os seguintes itens estão excluídos da garantia:
Custos de transporte e risco de transporte.
Danos causados por aplicação incorreta ou o não seguimento
das instruções de utilização.
Danos causados por vazamento das pilhas.
Danos causados devido a acidente ou má utilização.
Material / armazenamento de embalagem ou instrução de utili-
zação.
Verificações regulares e Manutenção (calibração).
Acessórios e peças: Baterias, adaptador de energia (opcional).
55BP A3 Plus
PT
A braçadeira tem uma garantia funcional (estanquicidade dabolsa
de ar) por 2 anos
Se for necessário o uso da garantia, por favor contacte o distri-
buidor da Marca Microlife. Pode contatar o seu serivço Microlife.
Pode contatar o seu serivço Microlife local através do nosso site:
www.microlife.com/support
Compensação é limitada ao valor do produto. A garantia será limi-
tada se o produto estiver completo e devolvido com a fatura
original de compra. Troca dentro do período de garantia não
prolonga ou renova o período de garantia. As reinvindicações
legais e direitos dos consumidores não são aplicados por esta
garantia.
12.Especificações técnicas
Este dispositivo está em conformidade com as exigências da
Norma de Dispositivos Médicos 93/42/EEC.
O fabricante reserva-se o direito de proceder a alterações
técnicas.
Condições de
funcionamento:
10 - 40 °C / 50 - 104 °F
15 - 95 % de humidade relativa máxima
Condições de
acondicionamento:
-20 - +55 °C / -4 - +131 °F
15 - 95 % de humidade relativa máxima
Peso: 368 g (incluindo pilhas)
Dimensões: 143 x 85 x 58 mm
Procedimento de
medição:
oscilométrico, correspondente ao
método Korotkoff: Fase I sistólica, Fase
V diastólica
Gama de medição: 20 - 280 mmHg – pressão arterial
40 - 200 batimentos por minuto –
pulsação
Gama de medição da
pressão da braçadeira: 0 - 299 mmHg
Resolução: 1 mmHg
Precisão estática: pressão dentro de ± 3 mmHg
Precisão da pulsação: ± 5% do valor obtido
Alimentação:
Pilhas alcalinas 4 x 1,5 V; tamanho AA
Adaptador DC 6 V, 600 mA (opcional)
Duração da pilha: aproximadamente 920 medições
(usando pilhas novas)
Classe IP: IP20
Normas de referência: EN 1060-1 /-3 /-4; IEC 60601-1;
IEC 60601-1-2 (EMC); IEC 60601-1-11
Duração expectável
de utilização:
Aparelho: 5 anos ou 10000 medições
Acessórios: 2 anos
56
Weergave
Lees alvorens dit apparaat te gebruiken de instructies
aandachtig door.
Geleverd onderdeel type BF
Het bedoelde gebruik:
Deze oscillometrische bloeddrukmonitor is bedoeld voor het non-
invasief meten van bloeddruk bij personen van 12 jaar of ouder.
Dit apparaat is klinisch gevalideerd voor patiënten met hyper-
tensie, hypotensie, diabetes, zwangerschap, pre-eclampsie, athe-
rosclerose, end-stage renal disease, obesitas en voor ouderen.
Geachte klant,
Deze bloeddrukmonitor is in samenwerking met artsen ontwikkeld
en klinische validatiestudies hebben aangetoond dat de meet-
nauwkeurigheid bijzonder hoog is.*
Mocht u vragen hebben of wanneer u reserveonderdelen wilt
bestellen, neemt u dan contact op met uw Microlife importeur. De
verkoper zal u het adres van de Microlife importeur in uw land geven.
Natuurlijk kunt u ook de website www.microlife.nl raadplegen, waar
u waardevolle informatie kunt vinden over onze producten.
Blijf gezond – Microlife AG!
* Dit apparaat gebruikt o.a. dezelfde meettechnologie als het geva-
lideerde model «BP 3BTO-A» getest conform het British and Irish
Hypertension Society (BIHS) protocol.
Microlife BP A3 Plus
NL
1
AAN/UIT knop
2
Display
3
Manchetaansluiting
4
Batterijcompartiment
5
Adapteraansluiting
6
Manchet
7
Manchetconnector
8
MAM Schakelaar
9
Gebruikersschakelaar
AT
M-knop (geheugen)
AK
Tijdknop
AL
Gebruikersindicator
AM
Batterijweergave
AN
Datum/tijd
AO
Systolische waarde
AP
Diastolische waarde
AQ
Hartslagfrequentie
AR
Verkeerslichtweergave indicator
AS
MAM Intervaltijd
BT
Hartslag
BK
Manchetcontrole indicator
BL
MAM Modus
BM
Onregelmatige hartslag (IHB) symbool
BN
Armbeweging indicator
BO
Opgeslagen waarden
Droog houden
57BP A3 Plus
NL
Inhoudsopgave
1. Belangrijke feiten over bloeddruk en het zelf meten
hiervan
Hoe meet ik mijn bloeddruk?
2. Eerste gebruik van het apparaat
Plaatsen van de batterijen
Instellen van datum en tijd
Selecteer de juiste manchet
Selecteren van de gebruiker
Selecteren van de standaardmodus of MAM modus
MAM modus (sterk aanbevolen)
3. Bloeddruk meten
Een meting uitvoeren zonder deze op te slaan
4. Uiterlijk van het symbool voor onregelmatige hartslag
(IHB)
5. Verkeerslichtindicatie in de weergave
6. Geheugenopslag
Bekijken van de opgeslagen waarden
Geheugen vol
Wis alle waarden
7. Batterij-indicator en batterijvervanging
Batterijen bijna leeg
Batterijen leeg – vervanging
Welke batterijen en welke werkwijze?
Gebruik van oplaadbare batterijen
8. Gebruik van een netadapter
9. Foutmeldingen
10. Veiligheid, onderhoud, nauwkeurigheidstest en verwi-
jdering
Veiligheid en bescherming
Apparaatonderhoud
Reinig de manchet
Nauwkeurigheidstest
Verwijdering
11. Garantie
12. Technische specificaties
Garantiebon (zie achterzijde)
1. Belangrijke feiten over bloeddruk en het zelf meten
hiervan
Bloeddruk is de druk waarmee het bloed door de aderen
stroomt veroorzaakt door het pompen van het hart. Twee
waarden, de systolische (boven) waarde en de diastolische
(onder) waarde worden altijd gemeten.
Het apparaat geeft ook de hartslagfrequentie (het aantal
keren dat het hart per minuut slaat) aan.
Constante hoge bloeddruk kan nadelig zijn voor uw
gezondheid en moet door uw arts worden behandeld!
Bespreek altijd uw waarden met uw arts en vertel hem/haar
wanneer u iets ongebruikelijks heeft opgemerkt of onzeker
bent. Vertrouw nooit op een enkele bloeddrukwaarde.
Er zijn verschillende oorzaken voor hoge bloeddrukwaarden.
Uw arts kan de gemeten waarden met u doornemen en indien
nodig een behandeling voorstellen. Naast medicatie kan een
gezondere levensstijl ook leiden tot verlaging van de bloeddruk
(bijv. dieet en meer beweging).
In geen enkel geval zou u de dosering van uw medicatie
moeten aanpassen of een behandeling starten zonder een
arts te raadplegen.
Afhankelijk van lichamelijke inspanning en conditie, is bloeddruk
onderhevig aan brede schommelingen gedurende de dag.
U
dient daarom de bloeddruk steeds onder dezelfde rustige
omstandigheden te meten en wanneer u zich ontspannen
voelt!
Meet tenminste twee keer 's morgens en twee keer 's
avonds en Neem het gemiddelde van alle metingen.
Het is vrij normaal wanneer twee metingen vlak na elkaar
genomen opvallend verschillende resultaten opleveren.
Daarom bevelen wij de MAM-technologie aan.
Afwijkingen tussen metingen genomen door uw arts of de
apotheek en die thuis zijn opgenomen zijn vrij normaal, omdat
deze situaties volledig verschillend zijn.
Verschillende metingen geven een veel duidelijker beeld van
uw bloeddruk dan slechts één enkele meting. Daarom bevelen
wij de MAM-technologie aan.
Neem een korte rustpauze van minimaal 15 seconden tussen
twee metingen.
Raadpleeg uw arts voordat u het apparaat gebruikt als u hartrit-
mestoornissen heeft. Zie ook hoofdstuk «Uiterlijk van het
symbool voor onregelmatige hartslag (IHB)» van deze gebrui-
kershandleiding.
58
De hartslagfrequentie is niet geschikt voor het controleren
van patiënten met een pacemaker!
Indien u zwanger bent adviseren wij u regelmatige uw bloed-
druk te meten, omdat uw bloeddruk drastisch kan veranderen
gedurende deze periode.
Deze meter is speciaal getest voor gebruik tijdens zwanger-
schap en pre-eclampsie. Wanneer u ongewoon hoge
metingen registreert, zou u de meting een tijd later moeten
herhalen (bijv. 1 uur). Indien de meting nog steeds te hoog
is, raadpleeg dan uw arts of gynaecoloog.
Hoe meet ik mijn bloeddruk?
De evaluatie van de waarden zijn conform de tabel. Bijvoorbeeld:
een waarde van de bloeddruk van 140/80 mmHg of een waarde
van 130/90 mmHg toont «bloeddruk te hoog».
2. Eerste gebruik van het apparaat
Plaatsen van de batterijen
Nadat u het apparaat heeft uitgepakt, plaatst u eerst de batterijen.
Het batterijcompartiment 4 bevindt zich aan de onderzijde van
het apparaat. Plaats de batterijen (4 x 1.5 V, grootte AA), let hierbij
op de aangegeven polariteit.
Instellen van datum en tijd
1. Nadat de batterijen zijn geplaatst knippert het jaartal in het scherm.
U kunt het jaar instellen door op de M-knop
AT
te drukken. Om te
bevestigen en vervolgens de maand in te stellen, drukt u op de tijd-
knop
AK
.
2. Nu kunt u de maand instellen met de M-knop. Druk op de tijd-
knop om te bevestigen en stel dan de dag in.
3. Volg de bovenstaande instructies om dag, uur en minuten in te
stellen.
4. Zodra u de minuten heeft ingesteld en de tijdknop indrukt, zijn
de datum en tijd ingesteld en wordt de tijd weergegeven.
5. Als u de datum en de tijd wilt veranderen, houdt u de tijdknop
ingedrukt gedurende ca. 3 seconden totdat het jaartal begint te
knipperen. Nu kunt u nieuwe waarden invoeren zoals hierboven
beschreven.
Selecteer de juiste manchet
Microlife heeft manchetten in verschillende maten. Selecteer de
manchetgrootte die overeenkomt met de omtrek van uw bovenarm
(de gemeten omtrek rond het midden van de bovenarm).
Voorgevormde «Easy» manchetten zijn optioneel verkrijg-
baar voor een eenvoudige bevestiging en meer comfort.
Gebruik alleen Microlife manchetten!
Neem contact op met uw Microlife importeur, als de bijgesloten
manchet 6 niet past.
Bevestig de manchet aan het apparaat middels de manchet-
connector 7 duw de connector 3 zo ver als mogelijk in het
apparaat.
Selecteren van de gebruiker
Met dit apparaat kunt u de resultaten van 2 gebruikers opslaan.
Stel, ór elke meting, de gebruikersschakelaar 9 in voor de
juiste gebruiker: gebruiker 1 of 2.
Gebruiker 1: schuif de schakelaar 9 omhoog zodat deze bij
gebruikersicoon 1 staat.
Gebruiker 2: schuif de schakelaar 9 omlaag zodat deze bij
gebruikersicoon 2 staat.
De eerste persoon die meet dient gebruiker 1 te selecteren.
Selecteren van de standaardmodus of MAM modus
Dit apparaat laat u kiezen tussen of standaard (standaard enkel-
voudige meting) of modus MAM (automatische drievoudige
meting). Om standaard modus te selecteren, schuift u de MAM
schakelaar 8 aan de zijkant van het apparaat in stand «1» en om
MAM modus te selecteren, schuift u deze schakelaar in stand «3».
Tabel voor de classificatie van thuis bloeddruk meetwaarden bij
volwassenen in overeenstemming met de internationale richtlijnen
(ESH, ESC, JSH). Data in mmHg.
Bereik
Systo-
lisch
Diasto-
lisch Advies
1. bloeddruk normaal < 120 < 74 Zelfcontrole
2.
bloeddruk optimaal
120 - 129 74 - 79 Zelfcontrole
3. bloeddruk
verhoogd
130 - 134 80 - 84 Zelfcontrole
4. bloeddruk te hoog 135 - 159 85 - 99 Win medisch
advies in
5. bloeddruk gevaar-
lijk hoog
160 100
Win dringend
medisch advies in!
Manchetgrootte voor omtrek van de bovenarm
S 17 - 22 cm
M 22 - 32 cm
M - L 22 - 42 cm
L 32 - 42 cm
L - XL 32 - 52 cm
59BP A3 Plus
NL
MAM modus (sterk aanbevolen)
In MAM modus, 3 metingen worden automatisch genomen in
volgorde en het resultaat wordt dan automatisch geanalyseerd
en weergegeven. Omdat de bloeddruk constant schommelt, is
een op deze manier bepaald resultaat betrouwbaarder dan een
die is verkregen door een enkele meting.
Wanneer u de MAM stand selecteert, verschijnt het MAM-
symbool BL in het display.
Het gedeelte rechtsonder in het display toont een 1, 2 of 3 om aan
te geven welke van de 3 metingen momenteel genomen wordt.
Tussen de metingen wordt een rusttijd van 15 seconden aange-
houden. Het aftellen wordt weergegeven in het scherm.
De individuele resultaten worden niet weergegeven. Uw bloeddruk
zal alleen worden getoond nadat alle 3 de metingen zijn verricht.
Verwijder de manchet niet tussen de metingen.
Als een van de afzonderlijke metingen twijfelachtig was, dan
wordt een vierde automatisch genomen.
3. Bloeddruk meten
Stappenplan voor een betrouwbare bloeddrukmeting
1. Vermijd activiteit, eten of roken vlak vóór een meting.
2. Ga zitten op een stoel met rugsteun en ontspan voor 5 minuten.
Houd uw voeten naast elkaar op de grond en zit niet met de
benen over elkaar.
3. Meet altijd aan dezelfde arm (normaal links). Het wordt
aanbevolen dat artsen bij een eerste bezoek van een patiënt
beide armen meet om de te meten arm te bepalen. Aan de arm
met de hogere bloeddruk moet worden gemeten.
4. Verwijder de kleding die de bovenarm bedekt, mouwen moeten
niet worden opgerold om afklemmen te voorkomen.
5. Zorg er altijd voor dat de juiste manchetmaat wordt gebruikt
(markering arm omtrek staat vermeld op het manchet).
Bevestig de manchet om de arm, maar niet te strak.
Zorg ervoor dat de manchet
1-2
cm boven uw elleboog is
geplaatst.
De artery mark op de manchet (ca. 3 cm lange bar) dient op
de ader van de arm (binnenkant) te worden gelegd.
Ondersteun uw arm zodat deze ontspannen is.
Zorg dat de manchet op dezelfde hoogte is als uw hart.
6. Druk op de AAN/UIT knop 1 om de meting te starten.
7. De manchet wordt nu automatisch opgeblazen. Ontspan,
beweeg niet en span uw armspieren niet totdat het meetresul-
taat wordt getoond. Adem normaal en praat niet.
8. Wanneer de juiste druk is bereikt, stopt het pompen en daalt de
druk langzaam. Als de gewenste druk niet werd bereikt, zal het
apparaat automatisch meer lucht in de manchet pompen.
9. Tijdens de meting knippert het hartslag symbool
BT
op het scherm.
10.Het resultaat, inclusief de systolische AO en de diastolische AP
bloeddruk en de hartslagfrequentie AQ wordt weergegeven.
Raadpleeg ook deze handleiding voor uitleg van de overige
weergaven.
11.Indien de meting klaar is, verwijder de manchet.
12.Schakel het apparaat uit. (De monitor gaat automatisch uit na
ongeveer. 1 min.).
Een meting uitvoeren zonder deze op te slaan
Zodra de meting is uitgevoerd en het resultaat wordt weergegeven in
het display houdt u de AAN/UIT knop
1
ingedrukt totdat de «
M
»
BO
in het display knippert. Druk dan vervolgens op de M-knop
AT
, dan
wordt de meting verwijderd en niet opgeslagen in het geheugen.
U kunt de meting op elk gewenst moment beëindigen door
op de AAN/UIT knop te drukken (bijv. wanneer u een onge-
makkelijke of een onplezierige druk voelt).
Als bekend is dat de systolische bloeddruk heel
hoog is, kan het gunstig zijn de druk individueel in te
stellen. Druk op de AAN/UIT knop nadat de monitor is opge-
pompt tot een niveau van ca. 30 mmHg (weergegeven in de
display). Hou de knop ingedrukt totdat de druk ca 40 mmHg
boven de verwachte waarde – laat dan de knop los.
4. Uiterlijk van het symbool voor onregelmatige hart-
slag (IHB)
Dit symboo BM geeft aan dat er een onregelmatige hartslag is
gedetecteerd. In dit geval kan de gemeten bloeddruk afwijken van
uw werkelijke bloeddrukwaarden. Het wordt aanbevolen om de
meting te herhalen.
5. Verkeerslichtindicatie in de weergave
De balken aan de linkerkant van het display AR toont de range
waarin de gemeten waarden liggen. Afhankelijk van de uitgelezen
waarde optimaal (groen), verhoogd (geel), te hoog (oranje) of
Informatie voor de arts in geval van het herhaaldelijk
verschijnen van het IHB-symbool
Dit apparaat is een oscillometrische bloeddrukmeter die ook de
pols meet tijdens bloeddrukmeting en aangeeft wanneer de hart-
slag onregelmatig is.
60
gevaarlijke hoog (rood) geeft het de overeenkomende kleur aan.
Deze classificaties zijn gebaseerd op internationale richtlijnen
(aan ESH, ESC, JSH), zoals beschreven in «sectie 1.».
6. Geheugenopslag
Dit apparaat heeft ruimte voor 99 metingen voor elk van de 2
gebruikers. De metingen worden automatisch opgeslagen.
Bekijken van de opgeslagen waarden
Selecteer gebruiker 1 of 2 met de gebruikersschakelaar 9.
Druk op de M-knop
AT
, wanneer het apparaat is uitgeschakeld. De
weergave toont eerst «
M
»
BO
en «
A
», wat staat voor het gemiddelde
van alle opgeslagen waarden.
Wederom op de M-knop drukken toont de vorige waarde. Door
nogmaals op de M-knop te drukken, kunt u door de meetresultaten
heen bladeren.
Geheugen vol
Let op dat de maximale geheugencapaciteit van 99 metingen
per gebruiker niet wordt overschreden.
Wanneer de 99 geheu-
genplaasten vol zijn, wordt de oudste meting automatisch
overschreven met de 100e meting.
Om gegevensverlies te
voorkomen, kunnen de meetwaarden worden geëvalueerd door
uw arts voordat de maximale geheugencapaciteit is bereikt.
Wis alle waarden
Controleer of u de juiste gebruiker heeft geselecteerd.
1. Selecteer gebruiker 1 of 2 met de gebruikersschakelaar 9 als
het apparaat uit staat.
2. Houd de M-knop AT ingedrukt totdat «CL» verschijnt en laat de
knop dan los.
3. Wanneer «CL» knippert druk dan op de M-knop om alle meet-
waarden permanent te verwijderen.
Om verwijdering te annuleren
druk op de AAN/UIT knop
1
wanneer «
CL
» knippert.
Losse meetwaarden kunnen niet worden gewist.
7. Batterij-indicator en batterijvervanging
Batterijen bijna leeg
Wanneer de batterijen ongeveer ¾ verbruikt zijn zal het batterij-
symbool AM knipperen zodra het apparaat ingeschakeld is
(gedeeltelijk geladen batterij wordt weergegeven). Alhoewel het
apparaat door zal gaan met betrouwbaar meten moet u batterijen
weldra vervangen.
Batterijen leeg – vervanging
Wanneer de batterijen leeg zijn, zal het batterijsymbool
AM
knipperen
zodra het apparaat ingeschakeld is (lege batterij weergegeven). U
kunt niet verder meten en moet de batterijen vervangen.
1. Maak het batterijcompartiment open 4 aan de onderzijde van
het apparaat.
2. Vervang de batterijen – controleer de juiste polariteit zoals
getoond door de symbolen in het compartiment.
3. Om de datum en de tijd in te stellen volg de procedure zoals
beschreven in «Paragraaf 2.».
Het geheugen bevat alle waarden alhoewel datum en tijd
gereset moeten worden – het jaartal knippert daarom auto-
matisch nadat de batterijen zijn vervangen.
Welke batterijen en welke werkwijze?
Gebruik
4
nieuwe, long-life 1,5V, type
AA
alkaline batterijen.
Gebruik ge en batterijen waarvan de uiterste verkoopdatum
is verstreken.
Verwijder de batterijen als het apparaat voor een langere
tijd niet gebruikt gaat worden.
Gebruik van oplaadbare batterijen
U kunt voor dit apparaat ook oplaadbare batterijen gebruiken.
Gebruik a.u.b. alleen type «NiMH» oplaadbare batterijen!
De batterijen moeten worden verwijderd en opgeladen, als
het batterijsymbool (batterij leeg) verschijnt! Ze moeten niet
in het apparaat blijven, omdat ze beschadigd kunnen raken
(volledige ontlading tengevolge van een minimaal gebruik
van het apparaat, zelfs wanneer het uitstaat).
Verwijder altijd de oplaadbare batterijen, als u niet van plan
bent het apparaat voor een week of langer te gebruiken!
De batterijen kunnen NIET worden opgeladen in de bloed-
drukmonitor! Laad deze batterijen op in een externe
oplader en houdt u aan de informatie met betrekking tot het
opladen, onderhoud en duurzaamheid!
8. Gebruik van een netadapter
U kunt dit apparaat met de Microlife netadapter (DC 6V, 600 mA)
gebruiken.
Gebruik alleen de origineel beschikbare
Microlife
netadapter
voor uw voedingsspanning.
Controleer dat zowel de netadapter als de kabel niet
beschadigd zijn.
1. Steek de adapter kabel in de netadapteraansluiting 5 van de
bloeddrukmonitor.
61BP A3 Plus
NL
2. Steek de netadapterstekker in de wandcontactdoos.
Wanneer de netadapter is aangesloten, wordt er geen batterij-
stroom gebruikt.
9. Foutmeldingen
Als er een fout optreedt, wordt de meting onderbroken en wordt
een foutmelding, b.v. «ERR 3», weergegeven.
* Neem a.u.b. onmiddelijk contact op met uw arts wanneer dit of
enig ander probleem vaker optreedt.
Als u denkt dat de resultaten ongebruikelijk zijn, leest u dan
a.u.b. zorgvuldig de informatie in «Paragraaf 1.».
10.Veiligheid, onderhoud, nauwkeurigheidstest en
verwijdering
Veiligheid en bescherming
Volg de instructies voor correct gebruik. Deze documentatie
voorziet u van belangrijke bedienings- en veiligheidsvoor-
schriften betreffende dit apparaat. Lees de documentatie zorg-
vuldig door vóór ingebruikname van het apparaat en bewaar
het voor latere raadpleging.
Dit apparaat mag uitsluitend worden gebruikt voor het doel
zoals in de gebruiksaanwijzing beschreven. De fabrikant kan
niet aansprakelijk worden gesteld voor schade veroorzaakt
door onjuist gebruik.
Dit apparaat bevat gevoelige componenten en moet met voor-
zichtigheid worden behandeld. Neem de bewaar- en bedie-
ningsvoorschriften in acht beschreven in het hoofdstuk «Tech-
nische specificaties»!
Bescherm het tegen:
- water en vochtigheid
- extreme temperaturen
- schokken en laten vallen
- vervuiling en stof
- direct zonlicht
- warmte en kou
De manchet is kwetsbaar en moet met zorgvuldigheid worden
behandeld.
Gebruik geen andere manchetten en/of manchetconnectors
dan geleverd bij het apparaat.
Alleen de manchet oppompen wanneer het aan de arm is
aangebracht.
Gebruik het apparaat niet dicht in de buurt van sterke elektro-
magnetische velden zoals mobiele telefoons of radioinstalla-
ties. Zorg voor een afstand van minimaal 3,3 meter van dit soort
apparaten, wanneer u dit apparaat in gebruik neemt.
Gebruik het apparaat niet wanneer u vermoedt dat het bescha-
digd is of wanneer u tijdens het gebruik iets ongebruikelijks
constateert.
Open het apparaat nooit.
Wanneer het apparaat voor een langere tijd niet gebruikt gaat
worden moeten de batterijen worden verwijderd.
Fout Beschrijving Mogelijke oorzaak en oplossing
«ERR 1» Signaal te
zwak
De polsslag wordt onvoldoende doorge-
geven door de manchet. Plaats de
manchet opnieuw en herhaal de meting.*
«ERR 2»
BN
Foutmelding
Tijdens het meten zijn er fouten ontstaan,
door bijvoorbeeld een beweging of
samentrekking van een spier. Herhaal de
meting terwijl u uw arm stil houdt.
«ERR 3»
BK
Geen juiste
drukopbouw
in de
manchet
Een adequate druk kan niet in de
manchet worden geproduceerd. Er kan
een lek in het manchet zijn. Controleer of
de manchet goed is aangesloten en niet
te los om de arm zit. Vervang de batte-
rijen indien nodig. Herhaal de meting.
«ERR 5» Abnormaal
resultaat
De meetsignalen zijn onbetrouwbaar en
daarom kan geen resultaat worden
weergegeven. Neem het stappenplan
door voor een betrouwbare meting en
herhaal dan de metingen.
«ERR 6» MAM Modus
Er waren teveel fouten tijdens het meten
in
MAM
mode, wat het onmogelijk maakt
om een betrouwbaar resultaat weer te
geven. Lees de controlelijst door voordat
u betrouwbare metingen verricht en
herhaal dan de metingen.
«HI» Hartslag of
manchet-
druk te hoog
De druk in de manchet is te hoog
(boven 299 mmHg) OF de hartslagfre-
quentie is te hoog (boven 200 slagen
per minuut). Ontspan gedurende
5 minuten en herhaal de meting.*
«LO» Polsslag te
laag
De hartslagfrequentie is te laag (minder
dan 40 slagen per minuut). Herhaal de
meting.*
62
Lees de verdere veiligheidsinstructies in de afzonderlijke para-
grafen van dit boekje.
De gemeten resultaten met dit apparaat stellen geen diagnose.
Het vervangt geen conslutatie van een arts, zeker niet wanneer
symptomen niet overeenkomen. Vertouw niet enkel op het
meetresultaat, neem altijd de overige symptomen in beschou-
wing, evenals de terugkoppling van de patient. Bij twijfel altijd
contact opnemen met uw arts.
Laat kinderen het apparaat alleen onder toezicht van een
volwassene gebruiken. Kleine onderdelen kunnen worden
ingeslikt. Wees alert op het gevaar van verstrengeling,
indien het apparaat is voorzien van kabels of slangen.
Apparaatonderhoud
Reinig het apparaat alleen met een zachte droge doek.
Reinig de manchet
Verwijder vlekken op de manchet met een vochtige doek en een
mild reinigingsmiddel.
WAARSCHUWING: Was de manchet nooit in de wasma-
chine en/of afwasmachine!
Nauwkeurigheidstest
Wij adviseren om dit apparaat elke 2 jaar op nauwkeurigheid te
laten testen of na mechanische schok (bijv. na een val). Neem
a.u.b. contact op met uw Microlife importeur om een algemene
functiecontrole aan te vragen (zie voorwoord).
Verwijdering
Batterijen en elektronische instrumenten moeten volgens
de plaatselijke regelgeving worden verwijderd, niet bij het
huishoudelijke afval.
11.Garantie
Dit apparaat heeft een garantie van 5 jaar vanaf aankoopdatum.
Tijdens deze garantieperiode zal Microlife het defecte product
gratis repareren of vervangen.
Opening van of wijzigingen aan het apparaat maken de garantie
ongeldig.
De volgende items zijn uitgesloten van garantie:
Transportkosten en transportrisico's.
Schade veroorzaakt door onjuist gebruik of niet-naleving van
de gebruiksaanwijzing.
Schade veroorzaakt door lekkende batterijen.
Schade veroorzaakt door vallen of verkeerd gebruik.
Verpakkings- / opslagmateriaal en gebruiksaanwijzing.
Regelmatige controles en onderhoud (kalibratie).
Accessoires en verbruiksmaterialen: Batterijen, voedings-
adapter (optioneel).
De manchet is gedekt door een functionele garantie (strakheid van
de blaas) gedurende 2 jaar.
Als garantie nodig is, neem dan contact op met de dealer waar u
het product hebt gekocht, of met uw lokale Microlife service. Ukan
via onze website contact opnemen met uw lokale Microlife dealer:
www.microlife.com/support
De vergoeding is beperkt tot de waarde van het product. De
garantie wordt verleend als het volledige product wordt geretour-
neerd met de originele factuur. Reparatie of vervanging binnen de
garantie verlengt of verlengt de garantieperiode niet. De wettelijke
claims en rechten van consumenten zijn nietbeperkt door deze
garantie.
12.Technische specificaties
Werkings-
condities:
10 - 40 °C / 50 - 104 °F
15 - 95 % maximale relatieve vochtigheid
Bewaarcondities: -20 - +55 °C / -4 - +131 °F
15 - 95 % maximale relatieve vochtigheid
Gewicht: 368 g (inclusief batterijen)
Afmetingen: 143 x 85 x 58 mm
Meetprocedure:
oscillometrisch, volgens de Korotkoff
methode: Fase I systolisch Fase V diastolisch
Meetbereik: 20 - 280 mmHg – bloeddruk
40 - 200 slagen per minuut – polsslag
Manchetdruk
weergave bereik: 0 - 299 mmHg
Resolutie: 1 mmHg
Statische
nauwkeurigheid: druk binnen ± 3 mmHg
Hartslagnauwkeu-
righeid: ±5 % van de weergegeven waarde
Spanningsbron:
4 x 1,5V alkaline batterijen; type AA
Netadapter DC 6V, 600 mA (optioneel)
Levensduur batterij:
ongeveer 920 metingen (met nieuwe batterijen)
IP Klasse: IP20
63BP A3 Plus
NL
Dit apparaat komt overeen met de normen van de richtlijn medische
hulpmiddelen 93/42/EEC.
Technische wijzigingen voorbehouden.
Verwijzing naar
normen:
EN 1060-1 /-3 /-4; IEC 60601-1;
IEC 60601-1-2 (EMC); IEC 60601-1-11
Verwachte
levensduur:
Apparaat: 5 jaar of 10000 metingen
Accessoires: 2 jaar
64
Οθόνη
Διαβάστε προσεκτικά τις οδηγίες πριν χρησιμοποιήσετε
αυτή τη συσκευή.
Τύπος BF εφαρμοσμένο τμήμα
Προβλεπόμενη χρήση:
Αυτό το παλμογραφικό πιεσόμετρο προορίζεται για τη μη επεμβα-
τική μέτρηση της πίεσης αίματος σε άτομα ηλικίας 12 ετών και άνω.
Είναι κλινικά εγκεκριμένο σε ασθενείς με υπέρταση, υπόταση,
διαβήτη, εγκυμοσύνη, προ-εκλαμψία, αρτηριοσκλήρωση, νεφρο-
πάθεια τελικού σταδίου, παχυσαρκία και στους ηλικιωμένους.
Αγαπητέ πελάτη,
Το όργανο αυτό σχεδιάστηκε σε συνεργασία με ιατρούς, ενώ
σύμφωνα με κλινικές δοκιμές αποδεικνύεται ότι η ακρίβεια
μέτρησής του είναι ιδιαίτερα υψηλή.*
Εάν έχετε οποιεσδήποτε απορίες ή προβλήματα
ή εάν θέλετε να
παραγγείλετε κάποιο ανταλλακτικό εξάρτημα, απευθυνθείτε στο
τοπικό σας τμήμα εξυπηρέτησης πελατών της Microlife. Ο
πωλητής σας ή το φαρμακείο της περιοχής σας θα σας ενημερώ-
σουν σχετικά με την διεύθυνση του αντιπροσώπου Microlife στην
χώρα σας. Εναλλακτικά, επισκεφθείτε την ιστοσελίδα μας στο
διαδίκτυο στη διεύθυνση www.microlife.com, όπου μπορείτε να
βρείτε πολλές χρήσιμες πληροφορίες σχετικά με τα προϊόντα μας.
Μείνετε υγιείς – Microlife AG!
* Το όργανο αυτό χρησιμοποιεί την ίδια τεχνολογία μετρήσεων με
το βραβευμένο μοντέλο «BP 3BTO-A», το οποίο έχει ελεγχθεί
σύμφωνα το πρωτόκολλο της Βρετανικής Εταιρείας Υπέρτασης
(BIHS).
Microlife BP A3 Plus
GR
1
Πλήκτρο ON/OFF
2
Οθόνη
3
Υποδοχή περιχειρίδας
4
Θήκη μπαταριών
5
Υποδοχή μετασχηματιστή ρεύματος
6
Περιχειρίδα
7
Βύσμα περιχειρίδας
8
Διακόπτης MAM
9
Διακόπτης χρήστη
AT
Πλήκτρο M (Μνήμη)
AK
Πλήκτρο χρόνου
AL
Δείκτης χρήστη
AM
Ένδειξη μπαταρίας
AN
Ημερομηνία/ώρα
AO
Τιμή συστολικής πίεσης
AP
Τιμή διαστολικής πίεσης
AQ
Σφύξεις
AR
Ένδειξη χρωματικής διαβάθμισης
AS
Ώρα μεσοδιαστήματος MAM
BT
Ένδειξη παλμών
BK
Ένδειξη ελέγχου περιχειρίδας
BL
Λειτουργία MAM
BM
Σύμβολο ακανόνιστου καρδιακού παλμού
(IHB)
BN
Ένδειξη κίνησης βραχίονα
BO
Αποθηκευμένη τιμή
Κρατήστε το στεγνό
65BP A3 Plus
GR
Πίνακας περιεχομένων
1. Σημαντικές πληροφορίες σχετικά με την αρτηριακή πίεση
και την αυτομέτρηση
Πώς να αξιολογήσω την αρτηριακή μου πίεση;
2. Χρήση της συσκευής για πρώτη φορά
Τοποθέτηση των μπαταριών
Ρύθμιση ημερομηνίας και χρόνου
Επιλέξτε τη σωστή περιχειρίδα
Επιλέξτε τον χρήστη
Επιλέξτε τη λειτουργία μέτρησης: τυπική ή MAM
Λειτουργία MAM (συνιστάται ιδιαίτερα)
3. Μέτρηση
της αρτηριακής πίεσης
Πώς να μην αποθηκεύσετε μια μέτρηση
4. Εμφάνιση του συμβόλου ακανόνιστου καρδιακού παλμού
(IHB)
5. Ένδειξη χρωματικής διαβάθμισης στην οθόνη
6. Μνήμη δεδομένων
Εμφάνιση των αποθηκευμένων τιμών
Μνήμη πλήρης
Διαγραφή όλων των τιμών
7. Ένδειξη μπαταρίας και αντικατάσταση μπαταριών
Μπαταρίες σχεδόν αποφορτισμένες
Μπαταρίες αποφορτισμένεςαντικατάσταση
Ποιες μπαταρίες και ποια διαδικασία
Χρήση
επαναφορτιζόμενων μπαταριών
8. Χρήση μετασχηματιστή ρεύματος
9. Μηνύματα σφάλματος
10. Ασφάλεια, φροντίδα, έλεγχος ακρίβειας και απόρριψη
Ασφάλεια και προστασία
Φροντίδα του πιεσόμετρου
Καθαρισμός της περιχειρίδας
Έλεγχος ακρίβειας
Απόρριψη
11. Εγγύηση
12. Τεχνικά χαρακτηριστικά
Κάρτα εγγύησης (βλ. οπισθόφυλλο)
1. Σημαντικές πληροφορίες σχετικά με την αρτηριακή
πίεση και την αυτομέτρηση
Η αρτηριακή πίεση είναι η πίεση του αίματος που ρέει μέσω
των αρτηριών, η οποία δημιουργείται από την άντληση της
καρδιάς. Πάντοτε μετρώνται δύο τιμές, η συστολική (επάνω)
τιμή και η διαστολική (κάτω) τιμή.
Το όργανο εμφανίζει επίσης τις σφύξεις (πόσες φορές η
καρδιά πάλλεται σε ένα λεπτό).
Η σταθερά υψηλή πίεση μπορεί να προκαλέσει βλάβη στην
υγεία και πρέπει να αντιμετωπιστεί από τον ιατρό σας!
Στον ιατρό σας πρέπει να αναφέρετε πάντοτε τις τιμές πίεσής
σας, εάν έχετε παρατηρήσει κάτι μη φυσιολογικό ή εάν δεν
είστε σίγουροι. Ποτέ μη βασίζεστε μόνο στις μετρήσεις της
αρτηριακής πίεσης.
Υπάρχουν πολλές αιτίες υπερβολικά υψηλής αρτηριακής
πίεσης. Ο ιατρός σας θα σας εξηγήσει τις αιτίες αυτές με
περισσότερες λεπτομέρειες
και θα σας χορηγήσει αγωγή
ανάλογα με την περίπτωση. Εκτός της φαρμακευτικής αγωγής,
η απώλεια βάρους και η άσκηση μπορούν επίσης να ελαττώ-
σουν την πίεση σας.
Σε καμία περίπτωση δεν πρέπει να αλλάξετε τη δοσολογία
των φαρμάκων ή να ξεκινήσετε μια θεραπεία χωρίς να
συμβουλευτείτε το γιατρό σας.
Ανάλογα με τη σωματική καταπόνηση και τη φυσική σας κατά-
σταση, η αρτηριακή πίεση κυμαίνεται σημαντικά στη διάρκεια
της ημέρας.
Για το λόγο αυτό, πρέπει να μετράτε την πίεσή
σας στις ίδιες συνθήκες ηρεμίας και όταν αισθάνεστε ότι
έχετε χαλαρώσει!
Κάνετε τουλάχιστον δυο μετρήσεις κάθε φορά
(το πρωί και το βράδυ) και πάρετε τον μέσο όρο των μετρήσεων.
Είναι αρκετά σύνηθες δύο διαδοχικές μετρήσεις να δίνουν
σημαντικά διαφορετικές τιμές. Ως εκ τούτου συνιστούμε την
χρήση τεχνολογίας MAM.
Οι αποκλίσεις μεταξύ των μετρήσεων από τον ιατρό σας ή το
φαρμακείο και των μετρήσεων στο σπίτι είναι αρκετά φυσιολο-
γικές, διότι οι συνθήκες είναι εντελώς διαφορετικές.
Πολλές μετρήσεις
παρέχουν πολύ περισσότερο αξιόπιστες
πληροφορίες σχετικά με την πίεση σας, από μια μεμονωμένη
μέτρηση. Ως εκ τούτου συνιστούμε την χρήση τεχνολογίας MAM.
Αφήστε ένα μικρό χρονικό περιθώριο τουλάχιστον
15 δευτερολέπτων μεταξύ δύο μετρήσεων.
Εάν υποφέρετε από καρδιακή αρρυθμία, συμβουλευτείτε το
γιατρό σας πριν χρησιμοποιήσετε τη συσκευή. Ανατρέξτε
66
επίσης στο κεφάλαιο «Εμφάνιση του συμβόλου ακανόνιστου
καρδιακού παλμού (IHB)» αυτού του εγχειριδίου χρήσης.
Η ένδειξη παλμού δεν είναι κατάλληλη για τον έλεγχο της
συχνότητας του βηματοδότη!
Εάν είστε έγκυος, πρέπει να παρακολουθείτε την αρτηριακή
σας πίεση τακτικά διότι μπορεί να ποικίλει σημαντικά στην
περίοδο της κύησης.
Αυτή η συσκευή είναι ειδικά ελεγμένη για χρήση κατά την
εγκυμοσύνη και την προεκλαμψία. Όταν εντοπίζετε ασυνή-
θιστα υψηλές τιμές μετρήσεων στην εγκυμοσύνη, θα
πρέπει να επαναλάβετε μετά από λίγο τη μέτρηση (π.χ. σε
1 ώρα) Εάν το αποτέλεσμα είναι ακόμα πολύ υψηλό,
συμβουλευτείτε το γιατρό ή τον γυναικολόγο σας.
Πώς να αξιολογήσω την αρτηριακή μου πίεση;
Η υψηλότερη τιμή είναι αυτή βάσει της οποίας καθορίζεται η αξιο-
λόγηση. Παράδειγμα: τιμή πίεσης 140/80 mmHg ή τιμή 130/90
mmHg υποδεικνύει «πολύ υψηλή πίεση».
2. Χρήση της συσκευής για πρώτη φορά
Τοποθέτηση των μπαταριών
Αφού αποσυσκευάσετε τη συσκευή, τοποθετήστε πρώτα τις
μπαταρίες. Η θήκη της μπαταριών 4 βρίσκεται στο κάτω μέρος
της συσκευής. Εισάγετε τις μπαταρίες (4 x 1,5 V μπαταρίες, μεγέ-
θους AA) προσέχοντας την ενδεικνυόμενη πολικότητα.
Ρύθμιση ημερομηνίας και χρόνου
1. Μετά την τοποθέτηση των καινούργιων μπαταριών, στην οθόνη
αναβοσβήνει ο αριθμός του έτους. Μπορείτε να ρυθμίσετε το έτος
πατώντας το πλήκτρο M
AT
. Για επιβεβαίωση και στη συνέχεια
για να ρυθμίσετε το μήνα, πατήστε το πλήκτρο χρόνου
AK
.
2. Τώρα μπορείτε να ρυθμίσετε το μήνα πατώντας το πλήκτρο M.
Πατήστε το πλήκτρο χρόνου για επιβεβαίωση και στη συνέχεια
ρυθμίστε την ημέρα.
3. Ακολουθήστε τις παραπάνω οδηγίες για να ρυθμίσετε την
ημέρα, την ώρα και τα λεπτά.
4. Μόλις ρυθμίσετε τα λεπτά και πατήσετε το πλήκτρο χρόνου,
ρυθμίζεται η ημερομηνία και η
ώρα και εμφανίζεται η ώρα.
5. Εάν θέλετε να αλλάξετε την ημερομηνία και την ώρα, πατήστε και
κρατήστε πατημένο το πλήκτρο επί 3 δευτ. περίπου μέχρις ότου
αρχίσει να αναβοσβήνει ο αριθμός του έτους. Τώρα μπορείτε να
εισάγετε τις νέες τιμές όπως περιγράφεται παραπάνω.
Επιλέξτε τη σωστή περιχειρίδα
Η Microlife προσφέρει διάφορα μεγέθη περιχειρίδων. Επιλέξτε το
μέγεθος περιχειρίδας που ταιριάζει στην περίμετρο του μπράτσου
σας (μετράται εφαρμοστά στο κέντρο του μπράτσου).
Προαιρετικές προ-φορμαρισμένες περιχειρίδες «Easy»
είναι διαθέσιμες για καλύτερη εφαρμογή και άνεση.
Χρησιμοποιείτε μόνο περιχειρίδες Microlife!
Επικοινωνήστε με το τοπικό σας τμήμα εξυπηρέτησης πελατών
της Microlife εάν η συνοδευτική περιχειρίδα 6 δεν ταιριάζει.
Συνδέστε την περιχειρίδα στο όργανο τοποθετώντας το βύσμα
της περιχειρίδας 7 στην υποδοχή της περιχειρίδας 3 όσο το
δυνατόν πιο μέσα.
Επιλέξτε τον χρήστη
Αυτή η συσκευή επιτρέπει την αποθήκευση αποτελεσμάτων για 2
μεμονωμένους χρήστες.
Πριν κάθε μέτρηση, ρυθμίστε τον διακόπτη χρήστη για τον
προβλεπόμενο χρήστη 9: Χρήστης 1 ή χρήστης 2.
Πίνακας για την ταξινόμηση τιμών μέτρησης πίεσης του αίματος
στο σπίτι, σε ενήλικες, σύμφωνα με τις διεθνείς οδηγίες (ESH,
ESC, JSH). Τα δεδομένα σε mmHg.
Εύρος τιμών
Συστο-
λική
Διαστο-
λική Σύσταση
1. αρτηριακή πίεση
φυσιολογική
< 120 < 74 Αυτοέλεγχος
2. αρτηριακή πίεση
βέλτιστη
120 - 129 74 - 79 Αυτοέλεγχος
3. αρτηριακή πίεση
αυξημένη
130 - 134 80 - 84 Αυτοέλεγχος
4. αρτηριακή πίεση
πολύ υψηλή
135 - 159 85 - 99 Ζητήστε ιατρική
συμβουλή
5. αρτηριακή πίεση
επικίνδυνα υψηλή
160 100 Ζητήστε επειγό-
ντως ιατρική
συμβουλή!
Μέγεθος περιχειρίδας για την περίμετρο του μπράτσου
S 17 - 22 cm
M 22 - 32 cm
M - L 22 - 42 cm
L 32 - 42 cm
L - XL 32 - 52 cm
67BP A3 Plus
GR
Χρήστης 1: Σύρετε το διακόπτη του χρήστη 9 προς τα επάνω
στο εικονίδιο του χρήστη 1.
Χρήστης 2: Σύρετε το διακόπτη του χρήστη 9 προς τα κάτω
στο εικονίδιο του χρήστη 2.
Το πρώτο άτομο που θα μετρηθεί θα πρέπει να επιλέξει τον
χρήστη 1.
Επιλέξτε τη λειτουργία μέτρησης: τυπική ή MAM
Αυτό το όργανο σάς δίνει τη δυνατότητα να επιλέξετε είτε την
τυπική λειτουργία (τυπική μονή μέτρηση) είτε τη λειτουργία MAM
(αυτόματη τριπλή μέτρηση). Για να επιλέξετε την τυπική
λειτουργία, μετακινήστε το διακόπτη MAM 8
που βρίσκεται στο
πλάι του οργάνου προς τα κάτω στη θέση «1», και για να επιλέ-
ξετε τη λειτουργία MAM, μετακινήστε το διακόπτη προς τα πάνω
στη θέση «3».
Λειτουργία MAM (συνιστάται ιδιαίτερα)
Στη λειτουργία
MAM
, πραγματοποιούνται αυτόματα 3 μετρήσεις
διαδοχικά και το αποτέλεσμα αναλύεται αυτόματα και εμφανί-
ζεται στην οθόνη. Επειδή η αρτηριακή πίεση μεταβάλλεται
διαρκώς, το αποτέλεσμα που μετράται με αυτό τον τρόπο είναι
πιο αξιόπιστο από αυτό που βασίζεται σε μία μόνο μέτρηση.
Όταν διαλέγετε την μέθοδο 3 μετρήσεων, το σύμβολο MAM BL
εμφανίζεται στην οθόνη.
Στο κάτω δεξί μέρος της οθόνης εμφανίζεται ο αριθμός 1, 2 ή 3,
ανάλογα ποια από τις 3 μετρήσεις πραγματοποιείται τη συγκε-
κριμένη στιγμή.
Υπάρχει ένα διάλειμμα 15 δευτερολέπτων μεταξύ των μετρή-
σεων. Μια αντίστροφη μέτρηση υποδεικνύει τον υπολειπόμενο
χρόνο.
Τα αποτελέσματα κάθε
μέτρησης δεν εμφανίζονται ξεχωριστά.
Η αρτηριακή σας πίεση εμφανίζεται μόνο αφού ολοκληρωθούν
και οι 3 μετρήσεις.
Μην αφαιρείτε την περιχειρίδα μεταξύ των μετρήσεων.
Εάν μία από τις τρεις μετρήσεις ήταν αμφισβητήσιμη, πραγμα-
τοποιείται αυτόματα μια τέταρτη μέτρηση.
3. Μέτρηση της αρτηριακής πίεσης
Λίστα ελέγχων για την πραγματοποίηση αξιόπιστης
μέτρησης
1. Αποφύγετε τη σωματική δραστηριότητα, την κατανάλωση
φαγητού ή το κάπνισμα αμέσως πριν από τη μέτρηση.
2. Καθίστε σε καρέκλα με πλάτη και χαλαρώστε για 5 λεπτά.
Πατήστε τα πόδια σταθερά στο πάτωμα και μην τα σταυρώ-
νετε.
3. Η μέτρηση πρέπει να γίνεται πάντοτε στο ίδιο
χέρι
(συνήθως το αριστερό). Συνιστάται στους γιατρούς κατά την
πρώτη επίσκεψη ενός ασθενούς, να πραγματοποιούν μέτρηση
και στους δυο βραχίονες, προκειμένου να καθορίσουν ποιόν
βραχίονα θα μετρούν στο μέλλον. Πρέπει να μετρούν τον
βραχίονα με την υψηλότερη πίεση.
4. Αφαιρέστε τα εφαρμοστά ρούχα από το μπράτσο. Για να
αποφύγετε την περίσφιξη
, το μανίκι του πουκάμισου δεν
πρέπει να είναι γυρισμένο προς τα πάνω - δεν παρεμποδίζει
την περιχειρίδα εάν είναι κατεβασμένο.
5. Πάντα να βεβαιώνεστε ότι χρησιμοποιείτε το σωστό μέγεθος
περιχειρίδας (αναφέρεται στην περιχειρίδα).
Τοποθετήστε την περιχειρίδα εφαρμοστά, αλλά όχι πολύ
σφικτά.
Βεβαιωθείτε ότι η περιχειρίδα τοποθετείται 1-2 εκατοστά
πάνω από τον αγκώνα
σας.
Η
ένδειξη αρτηρία
που βρίσκεται στην περιχειρίδα (περίπου
3 εκατοστά) πρέπει να βρίσκεται πάνω από την αρτηρία η
οποία διατρέχει το εσωτερικό μέρος του βραχίονα.
Στηρίξτε τον πήχη του χεριού σας ώστε το χέρι σας να είναι
χαλαρό.
Βεβαιωθείτε ότι η περιχειρίδα βρίσκεται στο ίδιο ύψος με
την καρδιά σας.
6. Πατήστε το πλήκτρο ON/OFF 1 για να αρχίσει η μέτρηση.
7. Η περιχειρίδα θα φουσκώσει αυτόματα. Χαλαρώστε, μην κινήστε
και μη σφίγγετε τους μύες του χεριού σας μέχρι να εμφανιστεί η
τιμή της μέτρησης. Αναπνέετε φυσιολογικά και μη μιλάτε.
8. Όταν επιτευχθεί η σωστή πίεση, το φούσκωμα σταματά και η
πίεση μειώνεται σταδιακά. Εάν η σωστή πίεση δεν επιτευχθεί,
το όργανο θα διοχετεύσει αυτόματα περισσότερο αέρα μέσα
στην περιχειρίδα.
9. Κατά τη μέτρηση, η ένδειξη παλμού
BT
αναβοσβήνει στην οθόνη.
10.Εμφανίζεται το αποτέλεσμα, το οποίο περιλαμβάνει αρτηριακή
πίεση συστολική AO, διαστολική AP και την συχνότητα των
παλμών AQ. Δείτε επίσης τις επεξηγήσεις των υπόλοιπων
ενδείξεων στο παρόν φυλλάδιο.
11.Όταν η μέτρηση ολοκληρωθεί, αφαιρέστε την περιχειρίδα.
12.Aπενεργοποιήστε το όργανο. (Η οθόνη σβήνει αυτόματα μετά
από 1 λεπτό περίπου)
68
Πώς να μην αποθηκεύσετε μια μέτρηση
Μόλις εμφανιστεί η μέτρηση πιέστε και κρατήστε το πλήκτρο ON/
OFF 1 έως ότου το σύμβολο «M» BO αρχίσει να αναβοσβήνει.
Επιβεβαιώστε την διαγραφή της μέτρησης πιέζοντας το πλήκτρο
M AT.
Μπορείτε να σταματήσετε τη μέτρηση οποιαδήποτε στιγμή
εάν πατήσετε το πλήκτρο ON/OFF (π.χ. εάν δεν αισθάνεστε
άνετα ή εάν νιώθετε μια δυσάρεστη αίσθηση πίεσης).
Εάν υπάρχει ιστορικό υψηλής συστολικής πίεσης,
μπορεί να είναι ωφέλιμη η μεμονωμένη ρύθμιση της
πίεσης. Πατήστε το πλήκτρο ON/OFF όταν η ένδειξη
ανέλθει στα 30 mmHg περίπου (απεικονίζεται στην
οθόνη). Κρατήστε το πλήκτρο πατημένο μέχρι η πίεση να
φτάσει περίπου στα 40 mmHg πάνω από την αναμενόμενη
συστολική τιμήστη συνέχεια αφήστε το πλήκτρο.
4. Εμφάνιση του συμβόλου ακανόνιστου καρδιακού
παλμού (IHB)
Αυτό το σύμβολο BM υποδεικνύει ότι ανιχνεύθηκε ακανόνιστος
καρδιακός παλμός. Σε αυτή την περίπτωση, η μετρηθείσα αρτη-
ριακή πίεση μπορεί να αποκλίνει από τις πραγματικές τιμές
πίεσης του αίματος. Συνιστάται η επανάληψη της μέτρησης.
5. Ένδειξη χρωματικής διαβάθμισης στην οθόνη
Οι μπάρες στο αριστερό άκρο της οθόνης AR σας δείχνουν το
εύρος εντός του οποίου κυμαίνεται η ενδεικνυόμενη τιμή της αρτη-
ριακής πίεσης. Ανάλογα με το ύψος της ράβδου, η καταγραμμένη
τιμή βρίσκεται εντός του βέλτιστου (πράσινο), αυξημένου
(κίτρινο), πολύ υψηλού (πορτοκαλί) ή επικίνδυνα υψηλού
(κόκκινο) φάσματος. Η κατάταξη αντιστοιχεί
στις 4 σειρές του
πίνακα, όπως ορίζεται από τις διεθνείς οδηγίες (ESH, ESC, JSH),
όπως περιγράφεται στο «Ενότητα 1.».
6. Μνήμη δεδομένων
Η συσκευή αποθηκεύει αυτόματα πάνω από 99 μετρήσεις για
καθένα από τους 2 χρήστες.
Εμφάνιση των αποθηκευμένων τιμών
Επιλέξτε είτε τον χρήστη 1 ή 2 με το πλήκτρο χρήστη 9.
Πατήστε το πλήκτρο M
AT
στιγμιαία, όταν το όργανο είναι απενερ-
γοποιημένο. Αρχικά επιδεικνύεται στην οθόνη το σύμβολο «
M
»
BO
και «
A
», το οποίο αντιπροσωπεύει τον μέσο όρο όλων των αποθη-
κευμένων μετρήσεων.
Εάν πατήσετε ξανά το πλήκτρο Μ, στην οθόνη εμφανίζεται η
προηγούμενη τιμή. Εάν πατήσετε ξανά το πλήκτρο Μ επανειλημ-
μένα, έχετε τη δυνατότητα μετάβασης από τη μία αποθηκευμένη
τιμή στην άλλη.
Μνήμη πλήρης
Προσέξτε να μην υπερβείτε την μέγιστη δυνατότητα αποθή-
κευσης των 99 μετρήσεων ανά χρήστη.
Όταν η μνήμη 99
μετρήσεων είναι πλήρης, η παλαιότερη τιμή καλύπτεται
αυτόματα από την 100η τιμή μέτρησης.
Οι μετρήσεις θα
πρέπει να εκτιμηθούν από τον γιατρό σας προτού γεμίσει η
χωρητικότητα μνήμηςαλλιώς τα στοιχεία θα χαθούν.
Διαγραφή όλων των τιμών
Βεβαιωθείτε ότι έχει ενεργοποιηθεί ο σωστός χρήστης.
1. Επιλέξτε χρήστη 1 ή χρήστη 2 με τον διακόπτη χρήστη 9, όταν
η συσκευή είναι κλειστή.
2. Κρατήστε πατημένο το πλήκτρο Μ AT μέχρι το σύμβολο «CL»
να εμφανιστεί και μετά ελευθερώστε το πλήκτρο.
3. Κρατήστε πατημένο το πλήκτρο Μ για όσο το
σύμβολο «CL»
αναβοσβήνει και διαγράφει μόνιμα όλες τις μετρήσεις του
επιλεγμένου χρήστη.
Ακυρώστε την διαγραφή: Πιέστε το πλήκτρο ON/OFF 1
όσο το σύμβολο «CL» αναβοσβήνει.
Οι μεμονωμένες τιμές δεν μπορούν να διαγραφούν.
7. Ένδειξη μπαταρίας και αντικατάσταση μπαταριών
Μπαταρίες σχεδόν αποφορτισμένες
Όταν οι μπαταρίες έχουν αποφορτιστεί κατά τα ¾ περίπου, το
σύμβολο της μπαταρίας AM αναβοσβήνει μόλις το όργανο ενεργο-
ποιείται (εμφανίζεται μια μπαταρία φορτισμένη κατά το ήμισυ).
Παρ' ότι το όργανο συνεχίζει να μετρά με αξιοπιστία, πρέπει να
αγοράσετε καινούργιες μπαταρίες.
Πληροφορίες για τον γιατρό σε περίπτωση επανειλημ-
μένης εμφάνισης του συμβόλου IHB
Αυτή η συσκευή είναι ένα παλμογραφικό πιεσόμετρο που μετρά
επίσης τον παλμό κατά τη διάρκεια της μέτρησης της πίεσης του
αίματος και υποδεικνύει πότε ο καρδιακός ρυθμός είναι ακανό-
νιστος.
69BP A3 Plus
GR
Μπαταρίες αποφορτισμένεςαντικατάσταση
Όταν οι μπαταρίες αποφορτιστούν εντελώς, το σύμβολο της μπατα-
ρίας
AM
αναβοσβήνει μόλις το όργανο ενεργοποιείται (εμφανίζεται
μια αποφορτισμένη μπαταρία). Δεν μπορείτε να πραγματοποιήσετε
άλλες μετρήσεις και πρέπει να αντικαταστήσετε τις μπαταρίες.
1. Ανοίξτε τη θήκη των μπαταριών 4 στην κάτω πλευρά της
συσκευής.
2. Αντικαταστήστε τις μπαταρίεςβεβαιωθείτε ότι η πολικότητα
είναι σωστή σύμφωνα με τα σύμβολα στη θήκη.
3. Για να ρυθμίσετε την ημερομηνία και ώρα, ακολουθήστε τη
διαδικασία που περιγράφεται στην «Ενότητα 2.».
Στη μνήμη διατηρούνται όλες οι τιμές, με εξαίρεση την
ημερομηνία και την ώρα που πρέπει να επαναρρυθμιστούν
ο αριθμός έτους αναβοσβήνει αυτόματα μετά την αντικα-
τάσταση των μπαταριών.
Ποιες μπαταρίες και ποια διαδικασία
Χρησιμοποιείτε
4
καινούργιες, μακράς διαρκείας, αλκαλικές
μπαταρίες 1,5 V, μεγέθους
AA
.
Μη χρησιμοποιείτε τις μπαταρίες μετά το πέρας της ημερο-
μηνίας λήξης τους.
Αφαιρέστε τις μπαταρίες, εάν δεν πρόκειται να χρησιμο-
ποιήσετε το όργανο για μεγάλο χρονικό διάστημα.
Χρήση επαναφορτιζόμενων μπαταριών
Το όργανο μπορεί επίσης να λειτουργήσει με επαναφορτιζόμενες
μπαταρίες.
Χρησιμοποιείτε μόνο επαναφορτιζόμενες μπαταρίες τύπου
«NiMH»!
Εάν εμφανιστεί το σύμβολο της μπαταρίας (αποφορτισμένες
μπαταρίες), πρέπει να αφαιρείτε τις μπαταρίες και να τις
επαναφορτίζετε! Δεν πρέπει να παραμένουν μέσα στο
όργανο, διότι ενδέχεται να υποστούν ζημιά (πλήρης
αποφόρτιση λόγω περιορισμένης χρήσης του οργάνου,
ακόμη κι αν έχει τεθεί εκτός λειτουργίας).
Αφαιρείτε πάντοτε τις επαναφορτιζόμενες μπαταρίες, εάν
δεν πρόκειται να χρησιμοποιήσετε το όργανο επί μία εβδο-
μάδα ή περισσότερο!
Οι μπαταρίες ΔΕΝ μπορούν να φορτιστούν όταν βρίσκονται
μέσα στο πιεσόμετρο! Πρέπει να επαναφορτίζετε αυτές τις
μπαταρίες σε εξωτερικό φορτιστή και να παρατηρείτε τις ενδεί-
ξεις σχετικά με τη φόρτιση, τη φροντίδα και τη διάρκεια ζωής!
8. Χρήση μετασχηματιστή ρεύματος
Το όργανο μπορεί να λειτουργήσει με το μετασχηματιστή ρεύματος
Microlife
(
DC 6V, 600 mA
).
Χρησιμοποιείτε μόνο το τροφοδοτικό
Microlife
, διαθέσιμο ως
πρωτότυπο εξάρτημα κατάλληλο για την παροχή σας ρεύματος.
Βεβαιωθείτε ότι δεν έχει προκληθεί ζημιά ούτε στο μετα-
σχηματιστή ρεύματος ούτε στο καλώδιο.
1. Συνδέστε το καλώδιο του μετασχηματιστή στη σχετική
υποδοχή 5 στο πιεσόμετρο.
2. Συνδέστε το φις του μετασχηματιστή στην πρίζα του τοίχου.
Όταν ο μετασχηματιστής ρεύματος είναι συνδεδεμένος, δεν κατα-
ναλώνεται ρεύμα από την μπαταρία.
9. Μηνύματα σφάλματος
Εάν σημειωθεί κάποιο σφάλμα κατά τη μέτρηση, η μέτρηση
διακόπτεται και στην οθόνη εμφανίζεται ένα μήνυμα σφάλματος,
π.χ. «ERR 3».
Σφάλμα Περιγραφή Πιθανή αιτία και αντιμετώπιση
«ERR 1» Σήμα πολύ
ασθενές
Τα σήματα παλμών στην περιχειρίδα
είναι πολύ ασθενή. Επανατοποθετήστε
την περιχειρίδα και επαναλάβετε τη
μέτρηση.*
«ERR 2»
BN
Σήμα σφάλ-
ματος
Κατά τη μέτρηση, ανιχνεύθηκαν
σήματα
σφάλματος από την περιχειρίδα, τα
οποία προκλήθηκαν για παράδειγμα
από κίνηση του ατόμου ή σφίξιμο των
μυών. Επαναλάβετε τη μέτρηση, κρατώ-
ντας το βραχίονά σας ακίνητο.
«ERR 3»
BK
Δεν
υπάρχει
πίεση στην
περιχειρίδα
Δεν μπορεί να δημιουργηθεί επαρκής
πίεση στην περιχειρίδα. Ενδέχεται να
υπάρχει διαρροή. Βεβαιωθείτε ότι η
περιχειρίδα έχει
συνδεθεί σωστά και ότι
δεν έχει χαλαρώσει. Αντικαταστήστε τις
μπαταρίες εάν είναι απαραίτητο.
Επαναλάβετε τη μέτρηση.
«ERR 5» Μη φυσιο-
λογικό
αποτέλεσμα
Τα σήματα μέτρησης είναι ανακριβή και
συνεπώς δεν μπορεί να εμφανιστεί
κάποιο αποτέλεσμα στην οθόνη.
Διαβάστε τη λίστα ελέγχων για την πραγ-
ματοποίηση αξιόπιστων μετρήσεων και
στη συνέχεια επαναλάβετε τη μέτρηση.*
70
* Παρακαλώ συμβουλευτείτε άμεσα το γιατρό σας, εάν αυτό ή
οποιοδήποτε άλλο πρόβλημα παρουσιάζεται επανειλημμένα.
Εάν θεωρείτε ότι τα αποτελέσματα της μέτρησης δεν είναι
φυσιολογικά, διαβάστε προσεκτικά τις πληροφορίες στην
«Ενότητα 1.».
10. Ασφάλεια, φροντίδα, έλεγχος ακρίβειας και απόρριψη
Ασφάλεια και προστασία
Ακολουθήστε τις οδηγίες χρήσης. Αυτό το έγγραφο παρέχει
σημαντικές πληροφορίες σχετικά με τη λειτουργία του προϊό-
ντος και την ασφάλεια αυτής της συσκευής. Διαβάστε προσε-
κτικά αυτό το έγγραφο πριν χρησιμοποιήσετε τη συσκευή και
κρατήστε το για μελλοντική αναφορά.
H συσκευή αυτή πρέπει να χρησιμοποιείται για το σκοπό
που
περιγράφεται στο παρόν έντυπο οδηγιών. Ο κατασκευαστής
δεν φέρει καμία ευθύνη για τυχόν ζημιά που προκαλείται από
λανθασμένη χρήση.
Αυτή η συσκευή αποτελείται από ευαίσθητα εξαρτήματα και
πρέπει να το χειρίζεστε με προσοχή. Τηρείτε τις οδηγίες
αποθήκευσης και λειτουργίας που περιγράφονται στην
ενότητα «Τεχνικά χαρακτηριστικά»!
Προστατεύστε την από:
- νερό και υγρασία
- ακραίες θερμοκρασίες
- κρούση και πτώση
- μόλυνση και σκόνη
- άμεση έκθεση στον ήλιο
- ζέστη και κρύο
Οι περιχειρίδες είναι ευαίσθητες και πρέπει να τις χειρίζεστε με
προσοχή.
Μην αλλάζετε ή χρησιμοποιείτε άλλο είδος περιχειρίδας ή
βύσματος (περιχειρίδας) για μέτρηση με αυτή την συσκευή.
Φουσκώστε την περιχειρίδα μόνο
όταν έχει τοποθετηθεί στο
βραχίονα.
Μη χρησιμοποιείτε τη συσκευή κοντά σε ισχυρά ηλεκτρομα-
γνητικά πεδία, όπως κινητά τηλέφωνα ή ραδιόφωνο. Κρατήστε
απόσταση τουλάχιστον 3,3 m από αυτές τις συσκευές όταν
χρησιμοποιείτε την συσκευή.
Μη χρησιμοποιείτε τη συσκευή εάν θεωρείτε ότι έχει υποστεί
ζημιά ή εάν παρατηρήσετε κάτι ασυνήθιστο.
Ποτέ μην ανοίγετε
τη συσκευή.
Εάν δεν πρόκειται να χρησιμοποιήσετε τη συσκευή για μεγάλο
χρονικό διάστημα, πρέπει να αφαιρείτε τις μπαταρίες.
Διαβάστε τις πρόσθετες οδηγίες ασφάλειας στις ενότητες του
παρόντος φυλλαδίου.
Το αποτέλεσμα μέτρησης που δίδεται από την συσκευή δεν
αποτελεί διάγνωση. Δεν αντικαθιστά την ανάγκη συμβουλής
γιατρού, ειδικά αν δεν ταιριάζει
με τα συμπτώματα του ασθε-
νούς. Μην βασίζεστε μόνο στο αποτέλεσμα μέτρησης, πάντοτε
να εξετάζετε άλλα πιθανά συμπτώματα συνυπολογίζοντας την
γνώμη του ασθενούς. Συνιστούμε να καλέστε έναν γιατρό ή ένα
ασθενοφόρο εάν κριθεί αναγκαίο.
Βεβαιωθείτε ότι τα παιδιά δεν χρησιμοποιούν τη συσκευή
χωρίς επίβλεψη, διότι ορισμένα μέρη του είναι αρκετά
μικρά και υπάρχει κίνδυνος κατάποσης. Να είστε ενήμεροι
για τον κίνδυνο στραγγαλισμού σε περίπτωση που αυτή η
συσκευή τροφοδοτείται με καλώδια ή σωλήνες.
Φροντίδα του πιεσόμετρου
Καθαρίζετε το όργανο μόνο με ένα απαλό στεγνό πανί.
Καθαρισμός της περιχειρίδας
Απομακρύνετε προσεκτικά τυχόν λεκέδες από την περιχειρίδα,
χρησιμοποιώντας υγρό πανί και σαπουνάδα.
ΠΡΟΕΙΔΟΠΟΙΗΣΗ: Μην πλένετε την περιχειρίδα στο
πλυντήριο ρούχων ή στο πλυντήριο πιάτων!
«ERR 6» Λειτουργία
MAM
Παρατηρήθηκαν πολλά σφάλματα στη
διάρκεια της μέτρησης στη λειτουργία
MAM, με αποτέλεσμα να μην είναι
εφικτός ο υπολογισμός ενός τελικού
αποτελέσματος. Διαβάστε τη λίστα
ελέγχων για την πραγματοποίηση αξιό-
πιστων μετρήσεων και στη συνέχεια
επαναλάβετε τη
μέτρηση.*
«HI» Πολύ
γρήγορος
παλμός ή
πολύ υψηλή
πίεση περι-
χειρίδας
Η πίεση στην περιχειρίδα είναι πολύ
υψηλή (πάνω από 299 mmHg) Ή ο
παλμός είναι πολύ γρήγορος (πάνω από
200 παλμοί/λεπτό). Χαλαρώστε επί 5
λεπτά και επαναλάβετε τη μέτρηση.*
«LO» Παλμός
πολύ αργός
Ο παλμός είναι πολύ αργός (κάτω από
40 παλμοί/λεπτό
). Επαναλάβετε τη
μέτρηση.*
Σφάλμα Περιγραφή Πιθανή αιτία και αντιμετώπιση
71BP A3 Plus
GR
Έλεγχος ακρίβειας
Συνιστάται να ελέγχετε την ακρίβεια αυτού του οργάνου κάθε
2 χρόνια ή εάν κτυπηθεί (εάν πέσει κάτω) Απευθυνθείτε στο
τοπικό σας τμήμα εξυπηρέτησης πελατών της Microlife για τον
σχετικό έλεγχο (βλ. εισαγωγή).
Απόρριψη
Η απόρριψη των μπαταριών και των ηλεκτρονικών οργάνων
πρέπει να πραγματοποιείται σύμφωνα με τους ισχύοντες
κανονισμούς, και όχι μαζί με τα οικιακά απορρίμματα.
11.Εγγύηση
Η συσκευή αυτή καλύπτεται από 5 ετή εγγύηση που ισχύει από
την ημερομηνία αγοράς. Κατά τη διάρκεια αυτής της περιόδου
εγγύησης, κατά την κρίση της, η Microlife θα επισκευάσει ή θα
αντικαταστήσει το ελαττωματικό προϊόν δωρεάν.
Σε περίπτωση ανοίγματος ή τροποποίησης της συσκευής, η
εγγύηση ακυρώνεται.
Τα ακόλουθα εξαιρούνται από την εγγύηση:
Κόστος και κίνδυνοι μεταφοράς.
Ζημιά που προκλήθηκε από εσφαλμένη εφαρμογή ή μη
συμμόρφωση με τις οδηγίες χρήσης.
Ζημιά που προκλήθηκε από διαρροή μπαταριών.
Ζημιά που προκλήθηκε από ατύχημα ή κακή χρήση.
Συσκευασία/υλικό αποθήκευσης και οδηγίες χρήσης.
Τακτικοί έλεγχοι και συντήρηση (βαθμονόμηση).
Αξεσουάρ και ανταλλακτικά: Μπαταρίες, μετασχηματιστής
ρεύματος (προαιρετικός).
Η περιχειρίδα καλύπτεται με λειτουργική εγγύηση (σφίξιμο
φούσκας) 2 ετών.
Εάν απαιτείται service εγγύησης, παρακαλώ επικοινωνήστε με
τον έμπορο από τον οποίο αγοράστηκε το προϊόν ή με το τοπικό
σας service Microlife. Mπορείτε να επικοινωνήσετε με το τοπικό
σας service Microlife μέσω της ιστοσελίδας μας:
www.microlife.com/support
Η αποζημίωση περιορίζεται στην αξία του προϊόντος. Η εγγύηση
θα
χορηγηθεί εάν το πλήρες προϊόν επιστραφεί συνοδευόμενο με
το αρχικό τιμολόγιο. Η επισκευή ή η αντικατάσταση εντός εγγύ-
ησης δεν παρατείνει ή ανανεώνει την περίοδο εγγύησης. Οι
νομικές αξιώσεις και τα δικαιώματα των καταναλωτών δεν θίγο-
νται από αυτήν την εγγύηση.
12.Τεχνικά χαρακτηριστικά
Η συσκευή συμμορφώνεται με τους κανονισμούς Ιατρικών
Συσκευών, σύμφωνα με την οδηγία 93/42/EEC.
Η εταιρεία διατηρεί το δικαίωμα για αλλαγή των τεχνικών χαρα-
κτηριστικών.
Συνθήκες λειτουργίας: 10 - 40 °C / 50 - 104 °F
15 - 95 % μέγιστη σχετική υγρασία
Συνθήκες αποθήκευσης: -20 - +55 °C / -4 - +131 °F
15 - 95 % μέγιστη σχετική υγρασία
Βάρος: 368 g (συμπ. των μπαταριών)
Διαστάσεις: 143 x 85 x 58 mm
Διαδικασία μέτρησης: παλμοσκοπική, κατά τη μέθοδο
Korotkoff: Φάση I συστολική, Φάση V
διαστολική
Εύρος
τιμών μέτρησης: 20 - 280 mmHg – αρτηριακή πίεση
40 - 200 παλμοί ανά λεπτόσφύξεις
Εύρος απεικονιζόμενων
τιμών πίεσης περιχει-
ρίδας: 0 - 299 mmHg
Ανάλυση: 1 mmHg
Στατική ακρίβεια: πίεση περίπου ± 3 mmHg
Ακρίβεια παλμού: ±5 % της τιμής μέτρησης
Πηγή τάσης:
4 x 1,5 V αλκαλικές μπαταρίες, μεγέ-
θους AA
Μετασχηματιστής συνεχούς ρεύματος
(DC) 6V, 600 mA (προαιρετικός)
Διάρκεια ζωής
μπαταρίας:
περίπου 920 μετρήσεις (με χρήση
νέων μπαταριών)
IP Κατηγορία: IP20
Συμμόρφωση με
πρότυπα:
EN 1060-1 /-3 /-4; IEC 60601-1;
IEC 60601-1-2 (EMC); IEC 60601-1-11
Αναμενόμενη διάρκεια
ζωής:
Συσκευή: 5 χρόνια ή 10000 μετρήσεις
Εξαρτήματα: 2 χρόνια
72
AR
Microlife BP A3 Plus
ϑΎϘϳϹ΍ϝϳϐηΗϟ΍έί
νέόϟ΍ΔηΎη
ω΍έΫϟ΍ϡ΍ίΣαΑϘϣ
˯ΎΑέϬϛϟ΍αΑϘϣ
ΔϳέΎρΑϟ΍ΓέϳΟΣ
ω΍έΫϟ΍ϡ΍ίΣ
ω΍έΫϟ΍ϡ΍ίΣϝ
˷
λϭϣ
ΕΎγΎϳϘϟ΍ργϭΗϣϟϑϳϻϭέϛϳΎϣMAMΡΎΗϔϣ
ϝϣόΗγϣϟ΍ϝ
˷
ϭΣϣ
Γέϛ΍Ϋϟ΍Mέί
Εϗϭϟ΍ρΑοέί
νέόϟ΍ΔηΎη
ϝϣόΗγϣϟ΍ΩϳΩΣΗ
ΔϳέΎρΑϟ΍έη΅ϣ
Εϗϭϟ΍ΦϳέΎΗϟ΍
ΔϳοΎΑϘϧϻ΍ΔϣϳϘϟ΍
ΔϳρΎγΑϧϻ΍ΔϣϳϘϟ΍
νΑϧϟ΍ϝΩόϣ
έϭέϣϟ΍˯ϭοέη΅ϣ
MAMϥϣίΕϗϭ
νΑϧϟ΍έη΅ϣ
ω΍έΫϟ΍ϡ΍ίΣϥϣϕϘΣΗϟ΍έη΅ϣ
ΕΎγΎϳϘϟ΍ργϭΗϣϟϑϳϻϭέϛϳΎϣMAMρϣϧ
(IHB) ΏϠϘϟ΍ΕΎΑέοϡΎυΗϧ΍ϡΩϋΓέΎη΍
ω΍έΫϟ΍ΔϛέΣέη΅ϣ
Γέϛ΍Ϋϟ΍
ϡ΍ΩΧΗγϻ΍ν΍έϏ΃
ϱ΃ϥϭΩΑϡΩϟ΍ρϐοαΎϳϘϟ΍ΫϫΕΎΑΫΑΫϟΎΑϡΩϟ΍ρϐοαΎϳϗίΎϬΟϡΩΧΗγϳ
ϪΑΡέλϣϭϫϭϕϭϓΎϣϓΔϧγ˺˻ϥγϥϣιΎΧηϷ΍ϯΩϟϡγΟϟ΍ϲϓϝΧΩΗ
ρϐονΎϔΧϧ΍ϰοέϣϭˬϡΩϟ΍ρϐοωΎϔΗέ΍ϰοέϣϊϣϡΩΧΗγϳϟΎ
˱
ϳέϳέγ
ˬΝΎόΗέϻ΍ΕΎϣΩϘϣϰοέϣϭˬϝϣ΍ϭΣϟ΍˯Ύγϧϟ΍ϭˬϱέϛγϟ΍ϰοέϣϭˬϡΩϟ΍
Δϧϣγϟ΍ϰοέϣˬΓέϳΧϷ΍ϝΣ΍έϣϟ΍ϲϓϰϠϛϟ΍ϰοέϣˬϥϳϳ΍έηϟ΍ΏϠλΗϭ
ϥγϟ΍έΎΑϛϭ
ˬίϳίόϟ΍ϥϭΑίϟ΍
αΎϳϘϟ΍ΫΧϷϕϭΛϭϣϲΑρίΎϬΟΩϳΩΟϟ΍ϑϳϻϭέϛϳΎϣϡΩϟ΍ρϐοΔΑϗ΍έϣίΎϬΟ
΍ΩΟϪΑϰ
˷
λϭϣϭϕϳϗΩˬϝΎϣόΗγϹ΍ρϳγΑϭϫϭϱϭϠόϟ΍ω΍έΫϟ΍ϰϠϋϥϣ
ϥϣϭ˯ΎΑρϷ΍ϊϣϥϭΎόΗϟΎΑίΎϬΟϟ΍΍Ϋϫέ
˷
ϭρϝίϧϣϟ΍ϲϓ
˷
ϡΩϟ΍ρϐοΔΑϗ΍έϣϟ
*
΍ΩΟϲϟΎόϟ΍ϯϭΗγϣϟ΍Ε΍ΫϪγΎϳϗΔϗΩΕΗΑΛ΃ϲΗϟ΍Δϳέϳέγϟ΍Ε΍έΎΑΗΧϹ΍ϝϼΧ
ϥΎϣϷ΍ΕΎϣϭϠόϣϭϑ΋Ύυϭϟ΍ϊϳϣΟϡϬϔϟΔϳΎϧόΑΕΎϣϳϠόΗϟ΍ϩΫϫΓ˯΍έϗϰΟέϳ
ϱ΃ϙϳΩϟϥΎϛ΍Ϋ·ϭϑϳϻϭέϛϳΎϣΞΗϧϣϝΎϣόΗγΎΑ
˱
΍ΩϳόγϥϭϛΗϥ΃ϙΩϳέϧ
ϥ΋ΎΑίϟ΍ΔϣΩΧΑϝΎλΗϻ΍˯ΎΟέϟ΍ˬέΎϳϏϊρϗΏϠρϟΔΟΎΣϭ΃ϝϛΎηϣϭ΃ˬϝ΍΅γ
ϰϠϋέΩΎϗϲϟΩϳλϟ΍ϭ΃ωίϭϣϟ΍ϥϭϛϳγϭϲϠΣϣϟ΍ϑϳϻϭέϛϳΎϣωίϭϣϟ
ΓέΎϳίϙϧϛϣϳˬϙϟΫϥϋϻΩΑϭϙΩϠΑϲϓϑϳϻϭέϛϳΎϣωίϭϣϥ΍ϭϧϋϙ΋Ύρϋ·
ΕΎϣϭϠόϣϟ΍ϥϣΓέϓϭΩΟΗγΙϳΣwww.microlife.comΕϧέΗϧϹ΍ϰϠϋΎϧόϗϭϣ
ΎϧΗΎΟΗϧϣϝϭΣΔϧϳϣΛϟ΍
Microlife AG !±ϙΗΣλϰϠϋυϓΎΣ
«BP 3BTO-A» ί΍έρϟ΍ϊοΧϳΙϳΣαΎϳϘϟ΍ΔϳϧϘΗαϔϧίΎϬΟϟ΍΍ΫϫϡΩΧΗγϳ
ΔϳϧΎρϳέΑϟ΍ϡΩϟ΍ρϐο˯ΎΑρ΃ΔϳόϣΟϝϭϛϭΗϭέΑϟΎ
˱
ϘϓϭΕ΍έΎΑΗΧϼϟί΋΍ϭΟϟΎΑί΋Ύϔϟ΍
(BIHS) ΔϳΩϧϟέϳϻ΍ϭ
ίΎϬΟϟ΍΍Ϋϫϡ΍ΩΧΗγ·ϝΑϗΔϳΎϧόΑΕΎϣϳϠόΗϟ΍΃έϗ·
BFρϣϧϪϳϠϋϕΑρϣ˯ίΟ
ϑΎΟϪϘΑ΍
73BP A3 Plus
AR
ΕΎϳϭΗΣϣϟ΍ϝϭΩΟ
ϲΗ΍Ϋϟ΍αΎϳϘϟ΍ϭ
˷
ϡΩϟ΍ρϐοϝϭΣΔϣΎϫϕ΋ΎϘΣ˺
ˮϲ
˷
ϣΩρϐοϡ
˷
ϳϗ΃ϑϳϛ
ϰϟϭϷ΍ΓέϣϠϟίΎϬΟϟ΍ϝΎϣόΗγ·˻
ΕΎϳέΎρΑϟ΍ϝΎΧΩ·
Εϗϭϟ΍ϭΦϳέΎΗϟ΍Ω΍Ωϋ·
΢ϳΣλϟ΍ω΍έΫϟ΍ϡ΍ίΣέΗΧ·
ϡΩΧΗγϣϟ΍ΩϳΩΣΗ
MAMρϣϧϭ΃ϲγΎϳϗαΎϳϘϟ΍ρϣϧέΗΧ·
ΎϬϣ΍ΩΧΗγ΍Δϳϣϫ΄Α΢λϧϧ
MAMρϣϧ
ϡΩϟ΍ρϐοαΎϳϘΑ΃ΩΑ΍˼
Γ˯΍έϗϥϳίΧΗϡΩϋΔϘϳέρ
IHBΏϠϘϟ΍ΕΎΑέοϡΎυΗϧ΍ϡΩϋΓέϟΎη΍έϭϬο˽
νέόϟ΍ϲϓΔϳ΋ϭοϟ΍Ε΍έη΅ϣϟ΍ ˾
ΕΎϧΎϳΑϟ΍Γέϛ΍Ϋ˿
ΔϧίΧϣϟ΍Ξ΋ΎΗϧϟ΍ΓΩϫΎηϣ
Δ΋ϠΗϣϣΓέϛ΍Ϋϟ΍
ϡϳϘϟ΍ϊϳϣΟ΢γϣ
ΔϳέΎρΑϟ΍έϳϳϐΗϭΔϳέΎρΑϟ΍έη΅ϣ̀
˯ΎϬΗϧϻ΍ϰϠϋΕΑέΎϗΕΎϳέΎρΑϟ΍
ϝ΍ΩΑΗγ΍ΕϬΗϧ΍ΕΎϳέΎρΑϟ΍
ˮ˯΍έΟϹ΍ϭϫΎϣϭΕΎϳέΎρΑϟ΍ωϭϧ
ϥΣηϠϟΔϠΑΎϘϟ΍ΕΎϳέΎρΑϟ΍ϝΎϣόΗγ·
˯ΎΑέϬϛϟ΍ΔϠλϭϝΎϣόΗγ·́
΄ρΧϟ΍ϝ΋Ύγέ̂
ίΎϬΟϟ΍ϥϣιϠΧΗϟ΍ϭΔϗΩϟ΍έΎΑΗΧ΍ϭΔϳΎϧόϟ΍ϭΔϣϼγϟ΍˺˹
ΔϳΎϣΣϟ΍ϭΔϣϼγϟ΍
ίΎϬΟϟΎΑΔϳΎϧόϟ΍
ω΍έΫϟ΍ϡ΍ίΣϑϳυϧΗ
ΔϗΩϟ΍έΎΑΗΧ΍
ίΎϬΟϟ΍ϥϣιϠΧΗϟ΍
ΔϟΎϔϛϟ΍˺˺
Δϳϧϔϟ΍ΕΎϔλ΍ϭϣϟ΍˺˻
ϲϔϠΧϟ΍ϑϼϐϟ΍έυϧ·ΔϟΎϔϛϟ΍ΔϗΎρΑ
ϲΗ΍Ϋϟ΍αΎϳϘϟ΍ϭ
˷
ϡΩϟ΍ρϐοϝϭΣΔϣΎϫϕ΋ΎϘΣ ˺
ΏϠϘϟ΍
˷
ΦοϥϋΞΗΎϧϟ΍ϭϥϳϳ΍έηϟ΍ϲϓϕ
˷
ϓΩΗϳϱΫϟ΍ρϐοϟ΍ϭϫ
˷
ϡΩϟ΍ρϐο
ΔϣϳϘϟ΍ϭΎϳϠόϟ΍ΔϳοΎΑϘϧϻ΍ΔϣϳϘϟ΍ΎϣϫΎϣ΋΍ΩΎϣϬγΎϳϗϡΗϳϥΎΗϣϳϗϪϟϭ
˷
ϡΩϠϟ
ϰϧΩϷ΍ΔϳρΎγΑϧϻ΍
ΏϠϘϟ΍ΎϬϳϓϕϔΧϳϲΗϟ΍Ε΍έϣϟ΍ΩΩϋΎοϳ΃νΑϧϟ΍ϝ
˷
Ωόϣϰϟ·ίΎϬΟϟ΍έϳηϳ
ΔϘϳϗΩϟ΍ϲϓ
ϥ΃ΏΟϳϭϙΗΣλϰϠϋέΛ΅Ηϥ΃ϥϛϣϳϡ΋΍ΩϝϛηΑΔϳϟΎόϟ΍
˷
ϡΩϟ΍ρϐοϡϳϗ
ϙΑϳΑρϝΑϗϥϣΞϟΎόΗ
ΕυΣϻ΍Ϋ·ΎϬΑϩέΑΧ΃ϭϙΑϳΑρϊϣΎϣ΋΍ΩϙΑΔλΎΧϟ΍
˷
ϡΩϟ΍ρϐοϡϳϗεϗΎϧ
˷
ϡΩϟ΍ρϐοΕ΍˯΍έϗϰϠϋΩϣΗόΗϻΩϛ΄ΗϣέϳϏΕϧϛϭ΃ϱΩΎϋέϳϏΊη
˷
ϱ΃
΍ΩΑ΃ΓΩέϔϧϣϟ΍
ΎϬΣϳ
˷
οϭΗΑϙΑϳΑρϡϭϘϳγ
˷
ϡΩϟ΍ρϐοϡϳϗωΎϔΗέ΍ΏΎΑγ΃
ϥϣΩϳΩόϟ΍ϙΎϧϫ
ΔϳϭΩϸϟϥϛϣϳϙϟΫϰϟ·ΔϓΎο·ϡίϠϳΎϣϛΝϼόϟ΍ΎϬϟϡΩϘϳϭέΛϛ΃ϝϳλϔΗΑ
˷
ϡΩϟ΍ρϐοωΎϔΗέ΍ϥϣΩΣΗϥ΃ϥϳέϣΗϟ΍ϭϥίϭϟ΍ϑϳϔΧΗϭ˯ΎΧέΗγϻ΍ϕέρϭ
˱
Ύοϳ΃
ϥϭΩΝϼϋϱ΃΃ΩΑΗϭ΃ϑϭέυϟ΍ϥϣϑέυϱ΃ΕΣΗϙΗϳϭΩ΃ΕΎϋέΟέϳϐ
˵
Ηϻ
˱
ϻϭ΃ϙΑϳΑρΓέΎηΗγ΍
ϊοΧϳ
˷
ϡΩϟ΍ρϐοϥΈϓˬΔϟΎΣϟ΍ϭϝϭΫΑϣϟ΍ϲϧΎϣγΟϟ΍ΩϬΟϟ΍ϰϠϋ΍ΩΎϣΗϋ΍
αϔϧϲϓϙΗΎγΎϳϗΫΧ΄Ηϥ΃ϙϟΫϟΏΟϳϭέΎϬϧϟ΍˯ΎϧΛ΃ΔΗϭΎϔΗϣΕΎΑ
˷
ϠϘΗϟ
ϝϛϝϗϷ΍ϰϠϋϥϳΗ˯΍έϗΫΧ΄ΑϡϗΔΣ΍έϟΎΑέόηΗΎϣΩϧϋϭΔ΋ΩΎϬϟ΍ϑϭέυϟ΍
ΕΎγΎϳϘϠϟργϭΗϣϝϣόΑϡϗϭ˯Ύγϣϟ΍ϭΡΎΑλϟ΍ϲϓΓέϣ
ΔϔϠΗΧϣΞ΋ΎΗϧ˯Ύρϋ·ϊϳέγΏϗΎόΗΑΎϣϫΫΧ΃ϡΗϥϳγΎϳϘϟ΍ΩΟϲόϳΑρϟ΍ϥϣ
MAMΎϳΟϭϟϭϧϛΗϡ΍ΩΧΗγΎΑ΢λϧϧ΍ΫϬϟ΍ΩΟ
ϙϠΗϭΔϳϟΩϳλϟ΍ϲϓϭ΃ϙΑϳΑρϝΑϗϥϣΎϫΫΧ΃ϡΗϲΗϟ΍ΕΎγΎϳϘϟ΍ϥϳΑΕϭΎϔΗϟ΍
ϥϋ΍ΩΟΔϔϠΗΧϣΕϻΎΣϟ΍ϩΫϫϥ΃ΙϳΣˬ΍ΩΟϲόϳΑρΕϳΑϟ΍ϲϓΓΫϭΧ΄ϣϟ΍
ΎϬοόΑ
΢λϧϧ΍ΫϬϟϙϣΩρϐοϥ΄ηΑΔϗΩέΛϛ΃ΕΎϣϭϠόϣϲρόΗΓΩΩόΗϣϟ΍ΕΎγΎϳϘϟ΍
MAMΎϳΟϭϟϭϧϛΗϡ΍ΩΧΗγΎΑ
ϥϳγΎϳϘϟ΍ϥϳΑΔϳϧΎΛ˺˾ϝϗϷ΍ϰϠϋΓέϳλϗΔΣ΍έΓέΗϓϙέΗ΍
ϝΑϗϙΑϳΑρέηΗγ΍ˬΏϠϘϟ΍ΕΎΑέοϡΎυΗϧ΍ϡΩϋϥϣϲϧΎόΗΕϧϛ΍Ϋ· 
ΔϣυΗϧϣϟ΍έϳϏΏϠϘϟ΍ΕΎοΑϧίϣέϝλϔϟ΍Ύ
˱
οϳ΃ϊΟ΍έίΎϬΟϟ΍ϡ΍ΩΧΗγ΍
΍ΫϫϡΩΧΗγϣϟ΍ϝϳϟΩϥϣIHB
ΏϠϘϟ΍ϡ
˷
υϧϣΩΩέΗϥϣϕϘΣΗϠϟΏγΎϧϣέϳϏνΑϧϟ΍νέϋ
ϥϛϣϳϪϧϷϡυΗϧϣϝϛηΑϙΑιΎΧϟ΍ϡΩϟ΍ρϐοΔΑϗ΍έϣ
˶
ϙϳϠϋϝϣΎΣ
˶
Εϧϛϥ·
ϙϠϣΣΓέΗϓϝϼΧέϳΑϛϝϛηΑέϳϐΗϳϥ΃
74
75BP A3 Plus
AR
ϡΩϟ΍ρϐοαΎϳϘΑ΃ΩΑ΍ ˼
ϪϳϠϋΩϣΗόϳαΎϳϗΫΧ΃ϥϣΩϛ΄Ηϟ΍Δϣ΋Ύϗ
αΎϳϘϟ΍ϝΑϗΓέηΎΑϣϥϳΧΩΗϟ΍ϭ΃ϝϛϷ΍ϭ΃ρΎηϧϝΫΑϯΩΎϔΗ ˺
ϕ΋ΎϗΩ˾ΓΩϣϟΡέΗγ΍ϭέϬυϪϟΩόϘϣϰϠϋαϠΟ΍ ˻
ϥϳόρΎϘΗϣϙϳϗΎγϭαϠΟΗϻϭνέϷ΍ϰϠϋ
˶
ϭΗγϣϝϛηΑϙϳϣΩϗϊο
˯ΎΑρϷ΍ϡΎϳϗ΢λϧ
˵
ϳ
˱
ΓΩΎϋέγϳϷ΍ϡλόϣϟ΍αϔϧϥϣ
˱
Ύϣ΋΍ΩαΎϳϘϟ΍ΫΧ ˼
ϝΟ΃ϥϣϰοέϣϠϟϰϟϭϷ΍ΓέΎϳίϟ΍ϝϼΧω΍έΫϠϟΔϳ΋ΎϧΛΕΎγΎϳϗ˯΍έΟΈΑ
ΏΟϳΙϳΣϝΑϘΗγϣϟ΍ϲϓαΎϳϘϠϟΎϬϣ΍ΩΧΗγ΍ϡΗϳγϱΫϟ΍ω΍έΫϟ΍ΩϳΩΣΗ
ϡΩϟ΍ρϐοϟΓ˯΍έϗϰϠϋ΃ϝΟγϳϱΫϟ΍ω΍έΫϟ΍ϡ΍ΩΧΗγ΍
ϥϭϛΗϻϥ΃ΏΟϳˬνΎΑϘϧϻ΍ϱΩΎϔΗϟϰϠϋϷ΍ω΍έΫϟ΍ϥϋΔϘ
˷
ϳοϟ΍αΑϼϣϟ΍ωίϧ΍
˽
ΔΣ
˷
ργϣΕϧΎϛ΍Ϋ·ω΍έΫϟ΍ϡ΍ίΣϲϓϝ
˷
ΧΩΗΗϻϲϬϓΔϓϭϔϠϣιϳϣϘϟ΍ϡΎϣϛ΃
ΔϗΎρΑΩΟϭΗω΍έΫϟ΍ϡ΍ίΣϟ΢ϳΣλϟ΍αΎϘϣϟ΍ϡ΍ΩΧΗγ΍ϥϣϥϣΩϛ΄Η ˾
ϡ΍ίΣϟ΍ϰϠϋΔϳΣϳοϭΗ
΍ΩΟϕ
˷
ϳοϝϛηΑαϳϟϥϛϟϥϛϟˬΓέηΎΑϣω΍έΫϟ΍ϡ΍ίΣαΑϟ΍
ϙϋϭϛϕϭϓέΗϣϳΗϧγ˻-˺ΔϓΎγϣϰϠϋϊοϭϳω΍έΫϟ΍ϡ΍ίΣ
˷
ϥ΄ΑΩ
˷
ϛ΄Η
ρϳέηω΍έΫϟ΍ϡ΍ίΣϰϠϋΓΩϭΟϭϣϟ΍ϥΎϳέηϟ΍ΔϣϼϋέϘΗγΗϥ΃ΏΟϳ
ω΍έΫϠϟϲϠΧ΍Ωϟ΍ΏϧΎΟϟ΍ϭΣϧΩΗϣϳϱΫϟ΍ϥΎϳέηϟ΍ϕϭϓϡγ˼ϝϭρΑ
˱
ΎΣΎΗέϣϥϭϛϳϟϙϋ΍έΫΩϧγ΍
ΏϠϘϟ΍ωΎϔΗέ΍αϔϧΑω΍έΫϟ΍ϡ΍ίΣ
˷
ϥ΄ΑΩϛ΄Η
αΎϳϘϟ΍˯ΩΑϟ
ϑΎϘϳ·ϝϳϐηΗέίϰϠϋρϐο΍ ˿
ΔϠοϋΩηΗϻϭϙ
˷
έΣΗΗϻˬϲΧέΗγ΍Ύϳϟ΁ϥϵ΍ΦϔΗϧϳγω΍έΫϟ΍ϡ΍ίΣ ̀
ϡ
˷
ϠϛΗΗϻϭΩΎΗόϣϝϛηΑα
˷
ϔϧΗαΎϳϘϟ΍ΔΟϳΗϧέϬυΗϰΗΣϙϋ΍έΫ
νϔΧϧϳϭ
˷
Φοϟ΍ϑ
˷
ϗϭΗϳˬ΢ϳΣλϟ΍ϯϭΗγϣϟ΍ϰϟ·ρϐοϟ΍ϝλϳΎϣΩϧϋ ́
˷
ΦοϳγˬΏϭϠρϣϟ΍ρϐοϟ΍ϰϟ·ϝϭλϭϟ΍ϡΗϳϡϟ΍Ϋ·ϲΟϳέΩΗϝϛηΑρϐοϟ΍
ω΍έΫϟ΍ϡ΍ίΣϲϓΎϳϟ΁έΛϛ΃˯΍ϭϫίΎϬΟϟ΍
νέόϟ΍ΔηΎηϲϓ
νΑϧϟ΍έη΅ϣνϣϭϳγˬαΎϳϘϟ΍˯ΎϧΛ΃ ̂
ϊϣνέό
˵
Ηϭ
ϲρΎγΑϧϻ΍ϭ ϲοΎΑϘϧϻ΍
˷
ϡΩϟ΍ρϐοϝϣηΗˬΔΟϳΗϧϟ΍
˷
ϥ·
˺˹
ΏϳΗϛϟ΍΍ΫϫϲϓϯέΧϷ΍Ε΍˯΍έϘϟΎΑΔλΎΧϟ΍Ε΍έϳγϔΗϟ΍Ύοϳ΃υΣϻ νΑϧϟ΍ϝΩόϣ
ω΍έΫϟ΍ϡ΍ίΣωίϧ΍ˬαΎϳϘϟ΍ΫΧ΃ϥϣίΎϬΟϟ΍ϲϬΗϧϳΎϣΩϧϋ
˺˺
ΔϘϳϗΩ˺ϲϟ΍ϭΣΩόΑ
˱˱
Ύϳϟ΁ΔηΎηϟ΍ΊϔρΗίΎϬΟϟ΍ϕϠϏ΃
˺˻
Γ˯΍έϗϥϳίΧΗϡΩϋΔϘϳέρ
ρϐοϟ΍ϲϓέϣΗγ΍Γ˯΍έϘϟ΍νέϋ˯ΎϧΛ΃
ϑΎϘϳ·ϝϳϐηΗέίϰϠϋρϐο΍
ϰϠϋρϐο΍ˬΩϳϛ΄ΗϠϟέίϟ΍έέΣϡΛ
«M»
έίνϣϭϳϰΗΣέίϟ΍ϰϠϋ
ϯέΧ΃Γέϣ
Mέί
ϑΎϘϳ·ϝϳϐηΗέίϰϠϋρϐοϟΎΑϥΎϛΕϗϭϱ΃ϲϓαΎϳϘϟ΍ϑϗϭΗϥ΃ϙϧϛϣϳ
%
΢ϳέϣέϳϏρϐοαΎγΣ·ϭ΃ΡΎϳΗέϻ΍ϡΩόΑέόηΗΕϧϛ΍Ϋ·ϙϟΫϰϠϋϝΎΛϣϭ
ΩϳΟϟ΍ϥϣϥϭϛϳΩϘϓˬ΍
˱
ΩΟϊϔΗέϣϲοΎΑϘϧϻ΍ϡΩϟ΍ρϐοϥ΃ϡϭϠόϣϟ΍ϥϣϥΎϛ΍Ϋ·
%
ϡΎϳϗΩόΑϝϳϐηΗϑΎϘϳ·ϝϳϐηΗέίϰϠϋρϐο΍ϱΩέϓϝϛηΑρϐοϟ΍ϥϳϳόΗ
ϰϠϋέϫΎυΎ
˱
ΑϳέϘΗϲϘΑ΋ίέΗϣϳϠϣ˼˹ϯϭΗγϣϰΗΣΦοϟΎΑϡΩϟ΍ρϐοΏϗ΍έϣ
˽˹ϲϟ΍ϭΣϰϟ·ρϐοϟ΍ϝλϳϰΗΣέίϟ΍ϰϠϋρϐοϟ΍ϲϓέϣΗγ΍ΔηΎηϟ΍
έίϟ΍έέΣϡΛ±ΔόϗϭΗϣϟ΍ΔϳοΎΑϘϧϻ΍ΔϣϳϘϟ΍ϕϭϓϲϘΑ΋ίέΗϣϳϠϣ
(IHBΏϠϘϟ΍ΕΎΑέοϡΎυΗϧ΍ϡΩϋΓέϟΎη΍έϭϬο ˽
ϩΫϫϲϓΔϣυΗϧϣέϳϏΏϠϗΕΎοΑϧϑΎηΗϛ΍ϡΗϪϧ΃ϰϟ·
ίϣέϟ΍΍Ϋϫέϳηϳ
ϰλϭϳΔϳϠόϔϟ΍ϡΩϟ΍ρϐοϡϳϗϥϋαΎϘϣϟ΍ϡΩϟ΍ρϐοϑέΣϧϳΩϗˬΔϟΎΣϟ΍
αΎϳϘϟ΍έ΍έϛΗΑ
IHBΓέΎη΍έϭϬοέ΍έϛΗϝΎΣϲϓΏϳΑρϟ΍ΓέΎηΗγ΍
Ύ
˱
οϳ΃νΑϧϟ΍αϳϘϳϲΑΫΑΫΗϟ΍ϡΩϟ΍ρϐοαΎϳϘϟίΎϬΟϥϋΓέΎΑϋίΎϬΟϟ΍΍Ϋϫ
ϡυΗϧϣέϳϏΏϠϘϟ΍ΕΎΑέοϝΩόϣϥ΃ϰϟ·έϳηϳϭϡΩϟ΍ρϐοαΎϳϗ˯ΎϧΛ΃
νέόϟ΍ϲϓΔϳ΋ϭοϟ΍Ε΍έη΅ϣϟ΍ ˾
έΎηϣϟ΍ϡΩϟ΍ρϐοΔΟϳΗϧϡϳϳϘΗϙϟέϬυϳ ΔηΎηϟ΍ϥϣϯέγϳϟ΍ΔϓΎΣϟ΍ϰϠϋ
έϣΣϷ΍ϭ΃ϲϟΎϘΗέΑΔϳϟΎϋ
˱
΍ΩΟˬέϔλ΃ΔόϔΗέϣˬέέοΧ΃ΔϳόϳΑρϪϳϟ·
ΔϳϬϳΟϭΗϟ΍ΉΩΎΑϣϟ΍ΎϬΗΩΩΣΎϣϛϝϭΩΟϟ΍ϲϓ˽ΕΎϗΎρϧέυΎϧϳϑϳϧλΗϟ΍ΓέϳρΧ
©˺ϡγϘϟ΍ªϲϓ΢οϭϣϭϫΎϣϛˬ(ESH, ESC, JSH)ˬΔϳϟϭΩϟ΍
ΕΎϧΎϳΑϟ΍Γέϛ΍Ϋ ˿
ϡΩΧΗγϣϝϛϟαΎϳϗ̂̂υϔΣΑ
˱˷
ΎϳϛϳΗΎϣϭΗϭ΃ϡϭϘϳίΎϬΟϟ΍
ΔϧίΧϣϟ΍Ξ΋ΎΗϧϟ΍ΓΩϫΎηϣ
ϡΩΧΗγϣϟ΍ϝϭΣϣΔργ΍ϭΑ ˻ϭ΃˺ϡΩΧΗγϣϟ΍έΗΧ΍
ΔηΎηνέόΗ
ΊϔρϣίΎϬΟϟ΍ϥϭϛϳΎϣΩϧϋˬΓίϳΟϭΓΩϣϟ Mέίρϐο·
ΔϧίΧϣϟ΍ϡϳϘϟ΍ΔϓΎϛργϭΗϣϰϟ·ίϣέϳϱΫϟ΍ˬ
«A»
ϭ
 «M»ϻϭ΃νέόϟ΍
΍έ΍έϣMέίϰϠϋρϐοϟ΍ϭϕΑΎγϟ΍αΎϳϘϟ΍νέόϳMέίϰϠϋρϐοϟ΍ϥ·
έΧ΁ϭυ
˷
ϔΣϣαΎϳϗϥϳΑϝϘϧΗϟ΍ϥϣϙϧ
˷
ϛϣϳ
Γ˯ϭϠϣϣΓέϛ΍Ϋϟ΍
˰ϟ΍ΊϠΗϣΗΎϣΩϧϋαΎϳϗ̂̂ϡΩΧΗγϣϝϛϟϰλϗϷ΍ΩΣϟ΍ϥ΃ϩΎΑΗϧϻ΍ϭΟέϧ
%
ϥ΃ϲϐΑϧϳαΎϳϗϡΩϗ΃ϥΎϛϣϝΣΗ˺˹˹ΔϣϳϘϟ΍ϥΈϓˬΓέϛ΍ΫϠϟαΎϳϗ̂̂
ΕΩϘϓϻ·ϭΎϬΗόγϰϟ·Γέϛ΍Ϋϟ΍ϝϭλϭϝΑϗΕΎγΎϳϘϟ΍ϡϳϳϘΗΑΏϳΑρϡϭϘϳ
ΕΎϧΎϳΑϟ΍
76
ΕΎγΎϳϘϟ΍ϊϳϣΟ΢γϣ
΢ϳΣλϟ΍ϡΩΧΗγϣϟ΍ΩϳΩΣΗϥϣΩϛ΄Η
ϥϭϛϳΎϣΩϧϋϙϟΫϭˬ user 2ϭ΃user 1ϰϠϋϡΩΧΗγϣϟ΍ϝ
˱
ϭΣϣρΑο΃ ˺
˴
Ύ΋ϔρϣίΎϬΟϟ΍
ϙόΑλ΍ϊϓέ΍ϡΛ
©
CL
ª
ίϣέέϭϬυϰΗΣ MέίϰϠϋ
˱
ϻ
˷
ϭρϣρϐο΍ ˻
ΩΩΣϣϟ΍ιΧηϠϟΕΎγΎϳϘϟ΍ϝϛϭΣϣϡΗϳϟΓΩΣ΍ϭΓ
˷
έϣMέίρϐο΍ϭΩϋ ˼
ϝϳϐηΗ
έίϰϠϋρϐοϟ΍έΑϋίΎϬΟϟ΍˯ΎϔρΈΑϡϗΕΎγΎϳϘϟ΍ϭΣϣ˯ΎϐϟϹ
%
©
CL
ª
ίϣέέϭϬυΩϧϋ
ϑΎϘϳ·
΢γϣΗϥ΃ϥϛϣϳϻΔϳΩέϔϟ΍ΕΎγΎϳϘϟ΍
%
ΔϳέΎρΑϟ΍έϳϳϐΗϭΔϳέΎρΑϟ΍έη΅ϣ ̀
˯ΎϬΗϧϻ΍ϰϠϋΕΑέΎϗΕΎϳέΎρΑϟ΍
νϣϭϳγ
ΔϳέΎρΑϟ΍ίϣέϥΈϓΎΑϳέϘΗΕΎϳέΎρΑϟ΍˽?˼ϝΎϣόΗγ΍ϡΗϳΎϣΩϧϋ
έϣΗγϳγίΎϬΟϟ΍ϥ΃ϥϣϡϏέϟΎΑΔ΋ϠΗϣϣϪΑηΔϳέΎρΑϟ΍νέόΗϝϣόϳίΎϬΟϟ΍ϭ
ΔϠϳΩΑΕΎϳέΎρΑϰϠϋϝλΣΗϥ΃ΏΟϳˬϕϭΛϭϣϝϛηΑαΎϳϘϟ΍ϲϓ
ϝϳΩΑΗΕϬΗϧ΍ΕΎϳέΎρΑϟ΍
ίΎϬΟϟ΍ϝϳϐηΗΩϧϋνϣϭϳγ
ΔϳέΎρΑϟ΍ίϣέϥΈϓˬΕΎϳέΎρΑϟ΍ϲϬΗϧΗΎϣΩϧϋ
ϥ΃ΏΟϳϭϯέΧ΃ΕΎγΎϳϗ
˷
ϱ΃ΫΧ΃ϊϳρΗγΗϻΔϳϬΗϧϣΔϳέΎρΑϟ΍νέόΗ
ΕΎϳέΎρΑϟ΍ϝΩΑΗγΗ
ίΎϬΟϟ΍ϝϔγ΃ϲϓ ΔϳέΎρΑϟ΍ΓέϳΟΣ΢Ηϓ΍ ˺
ϲϓίϭϣέϟΎΑϥϳΑϣϭϫΎϣϛΔΣϳΣλϟ΍ΔϳΑρϘϟ΍ϥϣΩϛ΄ΗΕΎϳέΎρΑϟ΍ϝΩΑΗγ΍ ˻
ΓέϳΟΣϟ΍
«˻ϡγϘϟ΍»ϲϓ΢οϭϣϟ΍˯΍έΟϹ΍ϊΑΗ΍ˬΕϗϭϟ΍ϭΦϳέΎΗϟ΍Ω΍ΩϋϹ ˼
Εϗϭϟ΍ϭΦϳέΎΗϟ΍ϥϳϳόΗΓΩΎϋ·ϰϟ·ΔΟΎΣϟ΍ϥϣϡϏέϟΎΑϡϳϘϟ΍ΔϓΎϛΑΓέϛ΍Ϋϟ΍υϔΗΣΗ
%
ΕΎϳέΎρΑϟ΍ϝ΍ΩΑΗγ΍ΩόΑϙϟΫϰϠϋ
˱
˯ΎϧΑΎ
˱
ϳ΋ΎϘϠΗΔϧγϟ΍ϡϗένϣϭϳΙϳΣ±
ˮ˯΍έΟ·
˷
ϱ΃ϭΕΎϳέΎρΑΔϳ΃
.AA alkalineϡΟΣΔϳέΎρΑV˺̄˾x˽
%
ΎϬ΋ΎϬΗϧ΍ΦϳέΎΗΩόΑΕΎϳέΎρΑϟ΍ϝϣόΗγΗϻ
%
ΔϠϳϭρΓΩϣϟίΎϬΟϟ΍ϝϣόΗγϳϥϟ΍Ϋ·ˬΕΎϳέΎρΑϟ΍ϝί΃
%
ϥΣηϠϟΔϠΑΎϘϟ΍ΕΎϳέΎρΑϟ΍ϝΎϣόΗγ·
ϥΣηϠϟΔϠΑΎϗΕΎϳέΎρΑϝΎϣόΗγΎΑΎοϳ΃ίΎϬΟϟ΍΍Ϋϫϝ
˷
ϐηΗϥ΃ϙϧϛϣϳ
ΔϳϧΎΛϝΎϣόΗγϼϟΔϠΑΎϘϟ΍ρϘϓ©NiMHªωϭϧΕΎϳέΎρΑϝΎϣόΗγ΍ϰΟέϳ
%
ΔϳέΎρΑϟ΍ίϣέέϬυ΍Ϋ·ˬΎϬϧΣηΩΎόϳϭϝ΍ίΗϥ΃ΏΟϳΕΎϳέΎρΑϟ΍
%
΢ΑλΗΩϗΫ·ˬίΎϬΟϟ΍ϝΧ΍ΩϰϘΑΗϻϥ΃ΏΟϳΔϳϬΗϧϣΔϳέΎρΑϟ΍
ˬίΎϬΟϠϟνϔΧϧϣϟ΍ϝΎϣόΗγϼϟΔΟϳΗϧϛϝλΣϳ
˷
ϲϠϛϟ΍ώϳέϔΗϟ΍Γέ
˷
έοΗϣ
΄ϔρϣϥϭϛϳΎϣΩϧϋϰΗΣ
ίΎϬΟϟ΍ϝΎϣόΗγ΍ϯϭϧΗϻΕϧϛ΍Ϋ·ˬΎϣ΋΍ΩϥΣηϠϟΔϠΑΎϘϟ΍ΕΎϳέΎρΑϟ΍ϝί΃
%
έΛϛ΃ϭ΃ωϭΑγ΃ΓΩϣϟ
ϩΫϫϥΣηΩϋ΃ϡ
˷
Ωϟ΍ρϐοΔΑϗ΍έϣίΎϬΟϲϓΕΎϳέΎρΑϟ΍ϥΣηΗϥ΃ϥϛϣϳϻ
%
ΔϳΎϧόϟ΍ϭϥΣηϟΎΑΔλΎΧϟ΍ΕΎϣϭϠόϣϟ΍υΣϻϭϲΟέΎΧϥΣΎηϲϓΕΎϳέΎρΑϟ΍
ΔϧΎΗϣϟ΍ϭ
˯ΎΑέϬϛϟ΍ΔϠλϭϝΎϣόΗγ΍ ́
έΎϳΗϠϟϑϳϻϭέϛϳΎϣϝϭΣϣΔϠλϭϝΎϣόΗγΎΑίΎϬΟϟ΍΍Ϋϫϝ
˷
ϐηΗϥ΃ϙϧϛϣϳ
έϳΑϣ΃ϲϠϠϣ˿˹˹ˬΕϟϭϓ˿έηΎΑϣέΎϳΗϲ΋ΎΑέϬϛϟ΍
ϕΣϠϣϛέϓϭΗϣϟ΍ϲ΋ΎΑέϬϛϟ΍έΎϳΗϠϟϑϳϻϭέϛϳΎϣϝϭΣϣΔϠλϭρϘϓϝϣόΗγ΍
%
ˬΔϳρϟϭϔϠϟΩϳϭίΗϟϲϠλ΃
ϲ΋ΎΑέϬϛϟ΍έΎϳΗϟ΍ϝϭΣϣϙϠγϭ΃ΔϠλϭϑϠΗϡΩϋϥϣΩϛ΄Η
%
ίΎϬΟϲϓ ϲ΋ΎΑέϬϛϟ΍έΎϳΗϟ΍ϝϭΣϣΔϠλϭαΑϘϣϰϟ·ΔϠλϭϟ΍ϙϠγϝΧΩ΃
˺
˷
ϡΩϟ΍ρϐοΔΑϗ΍έϣ
ρ΋ΎΣϟ΍αΑϘϣϰϟ·ϲ΋ΎΑέϬϛϟ΍έΎϳΗϟ΍ϝϭΣϣϟ΍αΑΎϗϝΧΩ΃ ˻
ΔϳέΎρΑϟ΍έΎϳΗϙϼϬΗγ΍ϡΗϳϻˬΔϟϭλϭϣϲ΋ΎΑέϬϛϟ΍έΎϳΗϟ΍ϝϭΣϣΔϠλϭϥϭϛΗΎϣΩϧϋ
΄ρΧϟ΍ϝ΋Ύγέ ̂
ϝΎΛϣϭˬ΄ρΧΔϟΎγένέόΗϭαΎϳϘϟ΍ΔόρΎϘϣϡΗϳˬαΎϳϘϟ΍˯ΎϧΛ΃΄ρΧΙΩΣ΍Ϋ·
©ERR 3ªϙϟΫϰϠϋ
΄ρΧϟ΍ϑλϭϟ΍ϪΟϼϋϭϝϣΗΣϣϟ΍ΏΑγϟ΍
©ERR 1ª
ΔϔϳόοΓέΎηϹ΍
΍ΩΟ
Δϔϳόοω΍έΫϟ΍ ϡ΍ίΣ ϰϠϋνΑϧϟ΍Ε΍έΎη·ΕϧΎϛ
˷
ϥ·
αΎϳϘϟ΍έ΍έϛΗϭω΍έΫϟ΍ϡ΍ίΣϊοϭΓΩΎϋ·ϡΗϳ΍ΩΟ
©ERR 2ª
΄ρΧΓέΎη·Δργ΍ϭΑ ΄ρΧϟ΍ Ε΍έΎη· ϑΎηΗϛ΍ ϡΗ ˬαΎϳϘϟ΍ ˯ΎϧΛ΃
έ
˷
ΗϭΗϥϣϝΎΛϣϟ΍ϝϳΑγϰϠϋΔΟΗΎϧϟ΍ˬω΍έΫϟ΍ϡ΍ίΣ
˱
ΎϧϛΎγϙϋ΍έΫϲϘΑ΃ˬαΎϳϘϟ΍έ
˷
έϛΔϛέΣϟ΍ϭ΃ΔϠοόϟ΍
©ERR 3ª
ρϐοΩΟϭϳϻ
ω΍έΫϟ΍ϡ΍ίΣϲϓ
ΎϣΑέ ω΍έΫϟ΍ ϡ΍ίΣ ϲϓ ϲϓΎϛ ρϐο έϳϓϭΗ ϥϛϣϳ ϻ
ω΍έΫϟ΍ϡ΍ίΣ
˷
ϥ΃ϥϣϕϘΣΗΙΩΣΩϗΏ
˷
έγΗϙΎϧϫϥϭϛϳ
ϝΩΑΗγ΍ ΍ΩΟ
˱
ΎϳΧέϣ αϳϟϭ ΢ϳΣλ ϝϛηΑ ϝλϭϣ
αΎϳϘϟ΍ΫΧ΃ΓΩΎϋΈΑϡϗΎϳέϭέοϙϟΫϥΎϛ΍Ϋ·ΕΎϳέΎρΑϟ΍
©ERR 5ª
Γ
˷
ΫΎηΔΟϳΗϧϟ΍ΔΟϳΗϧέϬυΗϥ΃ϥϛϣϳϻϭΔϘϳϗΩέϳϏαΎϳϘϟ΍Ε΍έΎη·
ϙϟΫΩόΑϭΔϗϭΛϭϣϟ΍ΕΎγΎϳϘϟ΍ΫΧϷϕϳϗΩΗϟ΍Δϣ΋Ύϗ΃έϗ΍
αΎϳϘϟ΍έ
˷
έϛ
©ERR 6ª
MAMρϣϧ
ˬMAMρϣϧϲϓαΎϳϘϟ΍˯ΎϧΛ΃˯ΎρΧϷ΍ϥϣέϳΛϛϟ΍ϙΎϧϫ
Δϳ΋ΎϬϧΔΟϳΗϧϰϠϋϝϭλΣϟ΍ϝϳΣΗγϣϟ΍ϥϣϪϠόΟϳΎϣϣ
ϙϟΫΩόΑϭΔϗϭΛϭϣϟ΍ΕΎγΎϳϘϟ΍ΫΧϷϕϳϗΩΗϟ΍Δϣ΋Ύϗ΃έϗ΍
*
αΎϳϘϟ΍έ
˷
έϛ
©HIª
ρϐοϭ΃νΑϧϟ΍
ϡ΍ίΣ
΍ΩΟϲϟΎϋω΍έΫϟ΍
˻̂̂ϥϣέΛϛ΃΍ΩΟϲϟΎϋω΍έΫϟ΍ϡ΍ίΣϲϓρϐοϟ΍
˷
ϥ·
ΔοΑϧ˻˹˹ϥϣέΛϛ΃΍ΩΟϊϔΗέϣνΑϧϟ΍ϥ΃ϭ΃ϲϘΑ΋ίϡϠϣ
* αΎϳϘϟ΍έ
˷
έϛϭϕ΋ΎϗΩ˾ΓΩϣϟϲΧέΗγ΍ΔϘϳϗΩϟ΍ϲϓ
©LOª
νϔΧϧϣνΑϧϟ΍
΍ΩΟ
ΔϘϳϗΩϟ΍ϲϓΔοΑϧ˽˹ϥϣϝϗ΃΍ΩΟνϔΧϧϣνΑϧϟ΍
*αΎϳϘϟ΍έ
˷
έϛ
ϯέΧ΃ΔϠϛηϣϱ΃ΙϭΩΣέ΍έϛΗΩϧϋϭ΃ϙϟΫΙΩΣϥ·έϭϔϟ΍ϰϠϋϙΑϳΑρΓέΎηΗγ΍˯ΎΟέΑ

ϲϓΕΎϣϭϠόϣϟ΍΃έϘΗϥ΃ϰΟέϳˬΔϳΩΎϋέϳϏΞ΋ΎΗϧϟ΍ϥ΄ΑΩϘΗόΗΕϧϛ΍Ϋ·
%
ΔϳΎϧόΑ«˺ϡγϘϟ΍»
77BP A3 Plus
AR
Ωϳίϣϟ΍έυϧ΍έΎΑΗΧϻ΍ΏϳΗέΗϟϲϠΣϣϟ΍
ιϠΧΗϟ΍
ΏΟϭϣΑΔϳϧϭέΗϛϟϹ΍Εϻϵ΍ϭΕΎϳέΎρΑϟ΍ϥϣι
˷
ϠΧΗϟ΍ϡΗϳϥ΃ΏΟϳ 
Δϳϟίϧϣϟ΍ΕΎϳΎϔϧϟ΍ϊϣαϳϟϭˬΎϳϠΣϣΔϘΑρϣϟ΍ΕΎϣϳϠόΗϟ΍
ΔϟΎϔϛϟ΍ ˺˺
ϥΎϣοϟ΍ ϱέγϳ ϻ .˯΍έηϟ΍ ΦϳέΎΗ ϥϣ Δϳ΍ΩΑ Ε΍ϭϧγ 5 ΓΩϣϟ ϥΎϣοΑ ίΎϬΟϟ΍ ΍Ϋϫ ϊΗϣΗϳ
ϭ΃ΡϼλΈΑ©MicrolifeªϡϭϘΗγˬΎϧέϳΩϘΗϟΎ
˱
ϘϓϭϭˬϩΫϫϥΎϣοϟ΍ΓέΗϓϝϼΧ
Ύ
˱
ϧΎΟϣΏϳόϣϟ΍ΞΗϧϣϟ΍ϝ΍ΩΑΗγ΍
.ϥΎϣοϟ΍ ϝΎρΑ· ϰϟ· ϪϠϳΩόΗ ϭ΃ ίΎϬΟϟ΍ ΢Ηϓ ϱΩ΅ϳ
ϥΎϣοϟ΍ϥϣΓΎϧΛΗγϣΔϳϟΎΗϟ΍έλΎϧόϟ΍
ϝϘϧϟ΍έρΎΧϣϭϝϘϧϟ΍ϑϳϟΎϛΗ
ΕΎϣϳϠόΗϟ ϝΎΛΗϣϻ΍ ϡΩϋ ϭ΃ ΢ϳΣλϟ΍ έϳϏ ϕϳΑρΗϟ΍ ϥϋ ΞΗΎϧϟ΍ έέοϟ΍
ϡ΍ΩΧΗγϻ΍
ΕΎϳέΎρΑϟ΍ΏέγΗϥϋϡΟΎϧϑϠΗ
ϡ΍ΩΧΗγ΍˯ϭγϭ΃ΙΩΎΣϥϋϡΟΎϧϟ΍έέοϟ΍
ϡ΍ΩΧΗγϻ΍ΕΎϣϳϠόΗϭϥϳίΧΗϟ΍ϑϳϠϐΗϟ΍ϭΔ΋ΑόΗϟ΍Ω΍ϭϣ
ΓέϳΎόϣϟ΍ΔϳέϭΩϟ΍ΔϧΎϳλϟ΍ϭιΣϔϟ΍
ϱέΎϳΗΧ΍ΔϗΎρϟ΍ϝϭΣϣˬΕΎϳέΎρΑϟ΍έΎϳϏϊρϗϭΕ΍έ΍ϭγγϛ΍
ϥϳϣΎϋΓΩϣϟΔϧΎΛϣϟ΍ϕϳοϲϔϳυϭϥΎϣοΑΓΎρϐϣΔϔϛϟ΍
˯΍έηϡΗϱΫϟ΍ϝϳϛϭϟΎΑϝΎλΗϻ΍ϰΟέϳˬΔΑϭϠρϣϟ΍ΔϣΩΧϟ΍ϥΎϣοΔϟΎΣϲϓ
MicrolifeΔϣΩΧΑϝΎλΗϻ΍ϙϧϛϣϳΔϳϠΣϣϟ΍MicrolifeΔϣΩΧϭ΃ˬϪϧϣΞΗϧϣϟ΍
www.microlife.com/supportΎϧόϗϭϣϝϼΧϥϣΔϳϠΣϣϟ΍
ΞΗϧϣϟ΍ωΎΟέ·ϡΗ΍Ϋ·ϥΎϣοϟ΍΢ϧϣϡΗϳγΞΗϧϣϟ΍ΔϣϳϗϰϠϋέλΗϘϳνϳϭόΗϟ΍
ϥΎϣοϟ΍ϥϣοϝ΍ΩΑΗγϻ΍ϭ΃ΡϼλϹ΍ϱΩ΅ϳϻΔϳϠλϷ΍ΓέϭΗΎϔϟ΍ϊϣϝϣΎϛϟΎΑ
ΕΎΑϟΎρϣϟ΍ϰϠϋϥΎϣοϟ΍΍ΫϫέλΗϘϳϻΎϫΩϳΩΟΗϭ΃ϥΎϣοϟ΍ΓέΗϓΔϟΎρ·ϰϟ·
ϥϳϛϠϬΗγϣϠϟΔϳϧϭϧΎϘϟ΍ϕϭϘΣϟ΍ϭ
Δϳϧϔϟ΍ΕΎϔλ΍ϭϣϟ΍ ˺˻
ίΎϬΟϟ΍ϥϣιϠΧΗϟ΍ϭΔϗΩϟ΍έΎΑΗΧ΍ϭΔϳΎϧόϟ΍ϭΔϣϼγϟ΍ ˺˹
ΔϳΎϣΣϟ΍ϭΔϣϼγϟ΍
ΔϳϠϣόϟ΍ϝϭΣΔϣΎϫΕΎϣϭϠόϣΩϧΗγϣϟ΍΍Ϋϫέϓϭϳϡ΍ΩΧΗγϼϟΕ΍ΩΎηέϹ΍ϊΑΗ΍ 
ίΎϬΟϟ΍ϡ΍ΩΧΗγ΍ϝΑϗΔϳΎϧόΑΔϘϳΛϭϟ΍ϩΫϫΓ˯΍έϗ˯ΎΟέϟ΍ίΎϬΟϟ΍΍ΫϫΔϣϼγϭ
ϝΑϘΗγϣϟ΍ϲϓΎϬϳϟ·ωϭΟέϠϟΎϬΑυΎϔΗΣϻ΍ϭ
ϻΕΎϣϳϠόΗϟ΍ϩΫϫϥϣοϪϟϥϳΑϣϟ΍νέϐϠϟρϘϓίΎϬΟϟ΍΍ΫϫϝΎϣόΗγ΍ϥϛϣϳ
ΊρΎΧϟ΍ϡ΍ΩΧΗγϻ΍ΏΑγΑέέοϟ΍Δϳϟϭ΅γϣϊϧΎλϟ΍ϝ
˷
ϣΣϳϥ΃ϥϛϣϳ
υΣϻέΫΣΑΎϬόϣϝϣΎόΗϟ΍ΏΟϳϭΔγΎ
˷
γΣΕΎϧ
˷
ϭϛϣϥϣϑϟ΄ΗϳίΎϬΟϟ΍΍Ϋϫ
Δϳϧϔϟ΍ΕΎϔλ΍ϭϣϟ΍ϡ
˷
γϗϲϓΔϧϳΑϣϟ΍ϝϳϐηΗϟ΍ϭϥϳίΧΗϟ΍ϑϭέυ
ϥϣίΎϬΟϟ΍ϲϣΣ·
ΔΑϭρέϟ΍ϭ˯Ύϣϟ΍
΍ΩΟΔϳϟΎόϟ΍Γέ΍έΣϟ΍ΕΎΟέΩ
ρϭϘγϟ΍ϭΕΎϣΩλϟ΍
έΎΑϐϟ΍ϭΙ
˷
ϭϠΗϟ΍
έηΎΑϣϟ΍αϣηϟ΍˯ϭο
ΓΩϭέΑϟ΍ϭΓέ΍έΣϟ΍
ΔϳΎϧόΑϝϣΎόΗϥ΃ΏΟϳϭΔγΎ
˷
γΣω΍έΫϟ΍ΔϣίΣ΃
˷
ϥ·
έΧ΁Ύ
˱
ϋϭϧϡΩΧΗγΗϭ΃ϪΑιΎΧϟ΍ϝλϭϣϟ΍ϭ΃ω΍έΫϟ΍ϡ΍ίΣϝΩΑΗγΗϻ
ίΎϬΟϟ΍΍Ϋϫϡ΍ΩΧΗγΎΑαΎϳϘϠϟ
ϪΑϳϛέΗϡΗϳΎϣΩϧϋρϘϓω΍έΫϟ΍ϡ΍ίΣΦϔϧ΍
ϙϠΗϝΛϣΔϳϭϘϟ΍ΔϳγϳρΎϧϐϣϭέϬϛϟ΍ϝϭϘΣϟ΍ϥϣΏέϘϟΎΑίΎϬΟϟ΍ϝϣόΗγΗϻ
ˬΔϳϛϠγϼϟ΍ϭϳΩ΍έϟ΍Ε΍ίϳϬΟΗϭ΃Δϟ΍ϭΟϟ΍ϑΗ΍ϭϬϟ΍ΓίϬΟ΃ϥϋΓέΩΎλϟ΍
έΗϣ˼̄˼ϥϋϝϘΗϻΔϓΎγϣϰϠϋϪΑυϔΗΣ΍ϭ
ϱΩΎϋέϳϏέϣ΃
˷
ϱ΃ΔυΣϼϣΩϧϋϭ΃ϑϟΎΗϪ
˷
ϧ΄ΑΩϘΗόΗΕϧϛ΍Ϋ·ίΎϬΟϟ΍ϝϣόΗγΗϻ
΍ΩΑ΃ίΎϬΟϟ΍΢ΗϔΗϻ
ΕΎϳέΎρΑϟ΍Δϟ΍ί·ΏΟϳΔϠϳϭρΓΩϣϟίΎϬΟϟ΍ϝϣόΗγΗϡϟ΍Ϋ·
ΏϳΗϛϟ΍΍ΫϫϥϣΔϳΩέϔϟ΍ϡΎγϗϷ΍ϲϓϯέΧϷ΍Δϣϼγϟ΍ΕΎϣϳϠόΗ΃έϗ΍
ϝΣϣϝΣϳϻϭϬϓ
˱
ΎλϳΧηΗαϳϟίΎϬΟϟ΍΍ΫϫΎϬϣΩϗϲΗϟ΍αΎϳϘϟ΍ΔΟϳΗϧϰϠϋ
νϳέϣϟ΍ν΍έϋ΃ΔϘΑΎρϣϥϛϳϡϟ΍Ϋ·ΎϣϳγϻˬΏϳΑρΓέΎηΗγ΍ϰϟ·ΔΟΎΣϟ΍
ϲΗϟ΍ϯέΧϷ΍ν΍έϋϷ΍ϲϓέυϧϟ΍
˱
Ύϣ΋΍ΩˬρϘϓαΎϳϘϟ΍ΔΟϳΗϧϰϠϋΩϣΗόΗϻ
ΓέΎϳγϭ΃ΏϳΑρ˯ΎϋΩΗγΎΑ΢λϧϳϰοέϣϟ΍ΕΎϘϳϠόΗϭΙΩΣΗϥ΃ϝϣΗΣϳ
έϣϷ΍ϡίϟ΍Ϋ·ϑΎόγ·
˯΍ίΟϷ΍νόΑ˭ϑ΍έη·ϥϭΩΑίΎϬΟϟ΍ϥϭϠϣόΗγϳϻϝΎϔρϷ΍ϥ΄ΑΩϛ΄Η
έρΧϥϣέΫΣ΍ΎϬϋϼΗΑ΍ϥϛϣϳΙϳΣΑΔϳΎϔϛϟ΍ϪϳϓΎϣΑΓέϳϐλ
ίΎϬΟϟ΍΍ΫϫΔϟΎΣϲϓϕΎϧΗΧϻ΍
ίΎϬΟϟΎΑΔϳΎϧόϟ΍
ΔϓΎΟϭαϣϠϣϟ΍ΔϣϋΎϧΔρϭϓϝΎϣόΗγΎΑρϘϓίΎϬΟϟ΍ϑυϧ
ω΍έΫϟ΍ϡ΍ίΣϑϳυϧΗ
ΔϠϠΑϣεΎϣϗΔόρϗϡ΍ΩΧΗγΎΑω΍έΫϟ΍ϡ΍ίΣϰϠϋϥϣϊϘΑϟ΍Δϟ΍ίΈΑέΫΣϝϛΑϡϗ
ϥϭΑΎλΓϭϏέϊϣ
ϥϭΣλϟ΍ΔϳϼΟϭ΃ΔϟΎγϐϟΎΑω΍έΫϟ΍ϡ΍ίΣϝγϐΗϻέϳΫΣΗ
ΔϗΩϟ΍έΎΑΗΧ΍
ϲϛϳϧΎϛϳϣϟ΍ϡ΍Ωρλϻ΍ΩόΑϭ΃ϥϳΗϧγ
˷
ϝϛΔϗΩϠϟίΎϬΟϟ΍΍ΫϫιΣϔΑϲλϭϧ
ϑϳϻϭέϛϳΎϣϟϥ΋ΎΑίϟ΍ΔϣΩΧΑϝΎλΗϷ΍ϰΟέϳρϘγϳϥ΃ϙϟΫϰϠϋϝΎΛϣϭ
ϝϳϐηΗϟ΍ρϭέη
ϥϳϳίΧΗϟ΍ρϭέη

ϥίϭ˰˰˰˰˰˰˰˰˰ϟ΍
ΩΎ˰˰˰˰˰˰ό˰˰˰˰˰˰˰ΑϷ΍
Ε΍˯΍έ˰˰˰˰˰˰˰Ο·
αΎ˰˰˰˰˰˰˰˰˰˰˰˰ϳϘϟ΍
αΎϳϘϟ΍ϯΩ˰ϣ

ρϐονέϋϯΩϣ
ω΍έΫϟ΍ϡ΍ίΣ
ΕϳΎϬϧέϬϓΔΟέΩ˺˹˽˾˹Δϳϭ΋ϣΔΟέΩ˽˹˺˹
ΕϳΎϬϧέϬϓΔΟέΩ˺˻˻˽Δϳϭ΋ϣΔΟέΩ˾˹˻˹
ΔϳΑγϧϟ΍ΔΑϭρέϠϟϰλϗϷ΍ΩΣϟ΍̃̂˹˺˾
ΕΎϳέΎρΑϟ΍ϥ
˷
ϣοΗϳϡ΍έΟ˼˿́
ϡϠϣ˾́î́˾î˺˽˼
ϑϭϛΗϭέϛΔϘϳέρϊϣϕϓ΍ϭΗϳˬΏΫΑΫΗϟ΍αΎϳϗ
ΔϳρΎγΑϧϻ΍˾ΔϠΣέϣˬΔϳοΎΑϘϧϻ΍˺ΔϠΣέϣ
˷
ϡΩϟ΍ρϐοϲϘΑ΋ίέΗϣϳϠϣ˻́˹˻˹
νΑϧΔϘϳϗΩϟ΍ϲϓΔοΑϧ˻˹˹˽˹
ϲϘΑ΋ίϡϠϣ˻̂̂˹
78
ΔϳΑρϟ΍ΓίϬΟϷΎΑΔλΎΧϟ΍ΕΎϬϳΟϭΗϟ΍ΕΎΑϠρΗϣϊϣίΎϬΟϟ΍΍Ϋϫϕϓ΍
EEC/93/42ΔϳΑέϭϷ΍ΔϳΩΎλΗϗϻ΍ΔϋϭϣΟ
ΔϳϧϓΕϼϳΩόΗ˯΍έΟ·ϕΣΑυϔΗ
Ρϭ˰οϭϟ΍ΔΟ
Δ˰ϧϛΎ˰γϟ΍Δϗ
ν˰Α˰ϧϟ΍Δ
έΩ˰˰˰˰λ
Δ˰ϳρϟϭ˰˰
ΔϳέΎρΑϟ΍έ
IP
α˰˰ϳϳΎϘϣϟ΍ΔϳόΟ
ϊϗϭΗϣϟ΍έϣ
ϲϘΑ΋ίϡϠϣ˺
ϲϘΑ΋ίϡϠϣ˼ϥϣορϐοϟ΍
Γ˯ϭέϘϣϟ΍ΔϣϳϘϟ΍ϥϣ̃˾
AAϡΟΣ˭AlkalineΔϳέΎρΑV˺̄˾x˽
ϱέΎϳΗΧ΍έϳΑϣ΃ϲϠϠϣ˿˹˹ˬέηΎΑϣέΎϳΗΕϟϭϓ˿ϲ΋ΎΑέϬϛϟ΍έΎϳΗϟ΍ϝϭΣϣ
ΓΩϳΩΟΕΎϳέΎρΑϡ΍ΩΧΗγΎΑΕΎγΎϳϘϟ΍̂˻˹ϲϟ΍ϭΣ
IP20
EN 1060-1 /-3 /-4; IEC 60601-1;
IEC 60601-1-2 (EMC); IEC 60601-1-11
ΕΎϳγΎϳϗ˺˹˹˹˹ϭ΃Ε΍ϭϧγ˾ίΎϬΟϟ΍
Ε΍ϭϧγ˻Ε΍έ΍ϭγγϛϻ΍
79BP A3 Plus
AR

Documenttranscriptie

Microlife BP A3 Plus EN  1 ES  8 FR  16 IT  24 DE  32 TR  40 PT  48 NL  56 GR  64 AR  72 Microlife AG Espenstrasse 139 9443 Widnau / Switzerland www.microlife.com Microlife UAB P. Lukšio g. 32, 08222 Vilnius Lithuania EC REP IB BP A3 Plus S-V10-1 1321 Revision Date: 2020-02-24 Microlife BP A3 Plus Guarantee Card (‫اﻟﻐﻄﺎء اﻟﺨﻠﻔﻲ‬ BP A3 Plus Name Purchaser / Nom de l'acheteur / Nome ‫اﻟﻜﻔﺎﻟﺔ‬of ‫ﺑﻄﺎﻗﺔ‬ del rivenditore / Name des Käufers / Alıcının adı / del comprador / Nome do comprador / ‫)اﻧﻈﺮ‬Nombre ‫اﻟﻜﻔﺎﻟﺔ‬koper ‫ﺑﻄﺎﻗﺔ‬ Naam / Ονοματεπώνυμο αγοραστή / ‫اﻟﻜﻔﺎﻟﺔ‬ ‫ﺑﻄﺎﻗﺔ‬ :‫اﺳﻢ اﻟﻤﺸﺘﺮي‬ (‫)اﻧﻈﺮ اﻟﻐﻄﺎء اﻟﺨﻠﻔﻲ‬ ‫ﺑﻄﺎﻗﺔ اﻟﻜﻔﺎﻟﺔ‬ :‫اﻟﻤﻮدﻳﻞ‬ :‫اﻟﻤﺸﺘﺮي‬ ‫ اﺳﻢ‬de série / Numero di Serial Number :‫اﻟﺘﺴﻠﺴﻞ‬ ‫ رﻗﻢ‬/ Numéro serie / Serien-Nr. / Seri numarası / Número de :‫اﻟﻤﻮدﻳﻞ‬ :‫اﻟﺸﺮاء‬ ‫ﺗﺎرﻳﺦ‬ ‫اﻟﻜﻔﺎﻟﺔ‬ ‫ﺑﻄﺎﻗﺔ‬ serie / Número de série / Serienummer / Αριθμός ‫رﻗﻢ‬ :‫اﻟﻤﺨﺘﺺ‬ ‫اﻟﺘﺎﺟﺮ‬ σειράς /:‫اﻟﺘﺴﻠﺴﻞ‬ (‫ﺑﻄﺎﻗﺔ اﻟﻜﻔﺎﻟﺔ )اﻧﻈﺮ اﻟﻐﻄﺎء اﻟﺨﻠﻔﻲ‬ :‫ﺗﺎرﻳﺦ اﻟﺸﺮاء‬ :‫اﺳﻢ اﻟﻤﺸﺘﺮي‬ Date :‫اﻟﻤﺨﺘﺺ‬ of Purchase‫اﻟﺘﺎﺟﺮ‬ / Date d'achat :‫اﻟﻤﻮدﻳﻞ‬/ Data d’acquisto / Kaufdatum / Satın alma tarihi / Fecha de compra / ‫ﺑﻄﺎﻗﺔ اﻟﻜﻔﺎﻟﺔ‬ :‫اﻟﺘﺴﻠﺴﻞ‬ ‫رﻗﻢ‬ Data da compra / Datum van aankoop / Ημερομηνία αγοράς /:‫ﺗﺎرﻳﺦ اﻟﺸﺮاء‬ (‫)اﻧﻈﺮ اﻟﻐﻄﺎء اﻟﺨﻠﻔﻲ‬ ‫ﺑﻄﺎﻗﺔ اﻟﻜﻔﺎﻟﺔ‬ :‫ اﺳﻢ اﻟﻤﺸﺘﺮي‬:‫اﻟﺘﺎﺟﺮ اﻟﻤﺨﺘﺺ‬ :‫اﻟﻤﻮدﻳﻞ‬ Specialist Dealer / Revendeur / Categoria rivenditore / Fachhändler / Uzman satıcı / Distribuidor :‫اﻟﺘﺴﻠﺴﻞ‬ ‫رﻗﻢ‬ especializado / Revendedor autorizado / Specialist :‫اﻟﺸﺮاء‬ ‫ﺗﺎرﻳﺦ‬ distributeur / Εξειδικευμένος αντιπρόσωποςa / :‫اﻟﺘﺎﺟﺮ اﻟﻤﺨﺘﺺ‬ W100 ١٢ BP A3 Plus BP W100 AR ١٢ BP W100 AR١٢ AR Microlife BP A3 Plus 1 2 3 4 5 6 7 8 9 AT AK ON/OFF button Display Cuff Socket Battery Compartment Mains Adapter Socket Cuff Cuff Connector MAM Switch User Switch M-button (memory) Time Button Display AL User Indicator AM Battery Display AN Date/Time AO Systolic Value AP Diastolic Value AQ Pulse Rate AR Traffic Light Indicator AS MAM Interval Time BT Pulse Indicator BK Cuff Check Indicator BL MAM Mode BM Irregular Heartbeat (IHB) Symbol BN Arm Movement Indicator BO Stored Value EN Intended use: This oscillometric blood pressure monitor is intended for measuring non-invasive blood pressure in people aged 12 years or older. It is clinically validated in patients with hypertension, hypotension, diabetes, pregnancy, pre-eclampsia, atherosclerosis, end-stage renal disease, obesity and the elderly. Dear Customer, This device was developed in collaboration with physicians and clinical tests carried out prove its measurement accuracy to be of a very high standard.* If you have any questions, problems or want to order spare parts please contact your local Microlife-Customer Service. Your dealer or pharmacy will be able to give you the address of the Microlife dealer in your country. Alternatively, visit the internet at www.microlife.com where you will find a wealth of invaluable information on our products. Stay healthy – Microlife AG! * This device uses the same measuring technology as the award winning «BP 3BTO-A» model tested according to the British and Irish Hypertension Society (BIHS) protocol. Read the instructions carefully before using this device. Type BF applied part Keep dry BP A3 Plus 1 EN Table of Contents 1. Important Facts about Blood Pressure and Self-Measurement • How do I evaluate my blood pressure? 2. Using the Device for the First Time • Inserting the batteries • Setting the date and time • Selecting the correct cuff • Selecting the user • Selecting standard or MAM mode • MAM mode (highly recommended) 3. Taking a Blood Pressure Measurement • How not to store a reading 4. Appearance of the Irregular Heartbeat (IHB) Symbol 5. Traffic Light Indicator in the Display 6. Data Memory • Viewing the stored values • Memory full • Clearing all values 7. Battery Indicator and Battery change • Low battery • Flat battery – replacement • Which batteries and which procedure? • Using rechargeable batteries 8. Using a Mains Adapter 9. Error Messages 10. Safety, Care, Accuracy Test and Disposal • Safety and protection • Device care • Cleaning the cuff • Accuracy test • Disposal 11. Guarantee 12. Technical Specifications Guarantee Card (see Back Cover) 2 1. Important Facts about Blood Pressure and SelfMeasurement  Blood pressure is the pressure of the blood flowing in the arteries generated by the pumping of the heart. Two values, the systolic (upper) value and the diastolic (lower) value, are always measured.  The device indicates the pulse rate (the number of times the heart beats in a minute).  Permanently high blood pressure values can damage your health and must be treated by your doctor!  Always discuss your values with your doctor and tell him/her if you have noticed anything unusual or feel unsure. Never rely on single blood pressure readings.  There are several causes of excessively high blood pressure values. Your doctor will explain them in more detail and offer treatment where appropriate. Besides medication, weight loss and exercise can also lower your blood pressure.  Under no circumstances should you alter the dosages of drugs or initiate a treatment without consulting your doctor.  Depending on physical exertion and condition, blood pressure is subject to wide fluctuations as the day progresses. You should therefore take your measurements in the same quiet conditions and when you feel relaxed! Take at least two readings every time (in the morning and in the evening) and average the measurements.  It is quite normal for two measurements taken in quick succession to produce significantly different results. Therefore we recommend using the MAM technology.  Deviations between measurements taken by your doctor or in the pharmacy and those taken at home are quite normal, as these situations are completely different.  Several measurements provide much more reliable information about your blood pressure than just one single measurement. Therefore we recommend using the MAM technology.  Leave a small break of at least 15 seconds between two measurements.  If you suffer from a cardiac arrhythmia consult with your doctor before using the device. See also chapter «Appearance of the Irregular Heartbeat (IHB) Symbol» of this user manual.  The pulse display is not suitable for checking the frequency of heart pacemakers!  If you are pregnant, you should monitor your blood pressure regularly as it can change drastically during this time. This monitor is specially tested for use in pregnancy and pre-eclampsia. When you detect unusual high readings in pregnancy, you should measure after a short while again (eg. 1 hour). If the reading is still too high, consult your doctor or gynecologist.  How do I evaluate my blood pressure? Table for classifying home blood pressure values in adults in accordance with the international Guidelines (ESH, ESC, JSH). Data in mmHg. Range 1. blood pressure normal 2. blood pressure optimum 3. blood pressure elevated 4. blood pressure too high 5. blood pressure dangerously high Systolic < 120 RecommendaDiastolic tion < 74 Self-check 120 - 129 74 - 79 Self-check 130 - 134 80 - 84 Self-check 135 - 159 85 - 99 ≥ 160 ≥ 100 Seek medical advice Urgently seek medical advice! The higher value is the one that determines the evaluation. Example: a blood pressure value of 140/80 mmHg or a value of 130/90 mmHg indicates «blood pressure too high». 2. Using the Device for the First Time Inserting the batteries After you have unpacked your device, first insert the batteries. The battery compartment 4 is on the bottom of the device. Insert the batteries (4 x 1.5 V, size AA), thereby observing the indicated polarity. Setting the date and time 1. After the new batteries are fitted, the year number flashes in the display. You can set the year by pressing the M-button AT. To confirm and then set the month, press the time button AK. 2. Press the M-button to set the month. Press the time button to confirm and then set the day. 3. Follow the instructions above to set the day, hour and minutes. BP A3 Plus 4. Once you have set the minutes and pressed the time button, the date and time are set and the time is displayed. 5. If you want to change the date and time, press and hold the time button down for approx. 3 seconds until the year number starts to flash. Now you can enter the new values as described above. Selecting the correct cuff Microlife offers different cuff sizes. Select the cuff size to match the circumference of your upper arms (measured by close fitting in the centre of the upper arm). Cuff size for circumference of upper arm S 17 - 22 cm M 22 - 32 cm M-L 22 - 42 cm L 32 - 42 cm L - XL 32 - 52 cm Optional preformed cuffs «Easy» are available for better fitting and comfort. Only use Microlife cuffs.  Contact your local Microlife Service if the enclosed cuff 6 does not fit.  Connect the cuff to the device by inserting the cuff connector 7 into the cuff socket 3 as far as it will go. Selecting the user This device allows to store the results for 2 individual users.  Before each measurement, set the user switch 9 for the intended user: user 1 or user 2.  User 1: slide the user switch 9 upwards to the user 1 icon.  User 2: slide the user switch 9 downwards to the user 2 icon. The first person to measure should select user 1.    Selecting standard or MAM mode This device enables you to select either standard (standard single measurement) or MAM mode (automatic triple measurement). To select standard mode, slide the MAM switch 8 on the side of the device downwards to position «1» and to select MAM mode, slide this switch upwards to position «3». MAM mode (highly recommended)  In MAM mode, 3 measurements are automatically taken in succession and the result is then automatically analysed and displayed. Because the blood pressure constantly fluctuates, a result determined in this way is more reliable than one produced by a single measurement. 3 EN  When you select the 3 measurements, the MAM-symbol BL appears in the display.  The bottom, right hand section of the display shows a 1, 2 or 3 to indicate which of the 3 measurements is currently being taken.  There is a break of 15 seconds between the measurements. A count down indicates the remaining time.  The individual results are not displayed. Your blood pressure will only be displayed after all 3 measurements are taken.  Do not remove the cuff between measurements.  If one of the individual measurements was questionable, a fourth one is automatically taken. 3. Taking a Blood Pressure Measurement Checklist for taking a reliable measurement 1. Avoid activity, eating or smoking immediately before the measurement. 2. Sit down on a back-supported chair and relax for 5 minutes. Keep the feet flat on the floor and do not cross your legs. 3. Always measure on the same arm (normally left). It is recommended that doctors perform double arm measurements on a patients first visit in order to determine which arm to measure in the future. The arm with the higher blood pressure should be measured. 4. Remove close-fitting garments from the upper arm. To avoid constriction, shirt sleeves should not be rolled up - they do not interfere with the cuff if they are laid flat. 5. Always ensure that the correct cuff size is used (marking on the cuff).  Fit the cuff closely, but not too tight.  Make sure that the cuff is positioned 1-2 cm above the elbow.  The artery mark on the cuff (ca. 3 cm long bar) must lie over the artery which runs down the inner side of the arm.  Support your arm so it is relaxed.  Ensure that the cuff is at the same height as your heart. 6. Press the ON/OFF button 1 to start the measurement. 7. The cuff will now pump up automatically. Relax, do not move and do not tense your arm muscles until the measurement result is displayed. Breathe normally and do not talk. 8. When the correct pressure is reached, the pumping stops and the pressure falls gradually. If the required pressure was not reached, the device will automatically pump some more air into the cuff. 9. During the measurement, the pulse indicator BT flashes in the display. 4 10.The result, comprising the systolic AO and the diastolic AP blood pressure and the pulse rate AQ is displayed. Note also the explanations on further display symbols in this booklet. 11.When the device has finished measuring, remove the cuff. 12.Switch off the device. (The monitor does switch off automatically after approx. 1 min.). How not to store a reading As soon as the reading is displayed press and hold the ON/OFF button 1 until «M» BO is flashing. Confirm to delete the reading by pressing the M-button AT. You can stop the measurement at any time by pressing the ON/OFF button (e.g. if you feel uneasy or an unpleasant pressure sensation). If the systolic blood pressure is known to be very high, it can be an advantage to set the pressure individually. Press the ON/OFF button after the monitor has been pumped up to a level of approx. 30 mmHg (shown on the display). Keep the button pressed until the pressure is about 40 mmHg above the expected systolic value – then release the button.   4. Appearance of the Irregular Heartbeat (IHB) Symbol This symbol BM indicates that an irregular heartbeat was detected. In this case, the measured blood pressure may deviate from your actual blood pressure values. It is recommended to repeat the measurement. Information for the doctor in case of repeated appearance of the IHB symbol: This device is an oscillometric blood pressure monitor that also measures the pulse during blood pressure measurement and indicates when the heart rate is irregular. 5. Traffic Light Indicator in the Display The bars on the left-hand edge of the display AR show you the range within which the indicated blood pressure value lies. Depending on the height of the bar, the readout value is either within the optimum (green), elevated (yellow), too high (orange) or dangerously high (red) range. The classification corresponds to the 4 ranges in the table as defined by the international guidelines (ESH, ESC, JSH), as described in «Section 1.». 6. Data Memory This device automatically stores up to 99 measurement values for each of the 2 users. Viewing the stored values Select either user 1 or 2 with the user switch 9. Press the M-button AT briefly, when the device is switched off. The display first shows «M» BO and «A», which stands for the average of all stored values. Pressing the M-button again displays the previous value. Pressing the M-button repeatedly enables you to move from one stored value to another. Memory full Pay attention that the maximum memory capacity of 99 memories per user is not exceeded. When the 99 memory is full, the oldest value is automatically overwritten with the 100th value. Values should be evaluated by a doctor before the memory capacity is reached – otherwise data will be lost.  Clearing all values Make sure the correct user is activated. 1. Select either user 1 or 2 with the user switch 9, when the device is switched off. 2. Hold down the M-button AT until «CL» appears and then release the button. 3. Press the M-button while «CL» is flashing to permanently clear all values of the selected user. Cancel deletion: press ON/OFF button 1 while «CL» is flashing. Individual values cannot be cleared.   7. Battery Indicator and Battery change Low battery When the batteries are approximately ¾ empty the battery symbol AM will flash as soon as the device is switched on (partly filled battery displayed). Although the device will continue to measure reliably, you should obtain replacement batteries. Flat battery – replacement When the batteries are flat, the battery symbol AM will flash as soon as the device is switched on (flat battery displayed). You cannot take any further measurements and must replace the batteries. 1. Open the battery compartment 4 on the bottom of the device. BP A3 Plus 2. Replace the batteries – ensure correct polarity as shown by the symbols in the compartment. 3. To set date and time, follow the procedure described in «Section 2.». The memory retains all values although date and time must be reset – the year number therefore flashes automatically after the batteries are replaced.  Which batteries and which procedure? Use 4 new, long-life 1.5 V, size AA alkaline batteries. Do not use batteries beyond their date of expiry. Remove batteries if the device is not going to be used for a prolonged period. Using rechargeable batteries You can also operate this device using rechargeable batteries. Only use «NiMH» type reusable batteries. Batteries must be removed and recharged when the flat battery symbol appears. They should not remain inside the device as they may become damaged (total discharge as a result of low use of the device, even when switched off). Always remove the rechargeable batteries if you do not intend to use the device for a week or more. Batteries cannot be charged in the blood pressure monitor. Recharge batteries in an external charger and observe the information regarding charging, care and durability.        8. Using a Mains Adapter You can operate this device using the Microlife mains adapter (DC 6V, 600 mA). Only use the Microlife mains adapter available as an original accessory appropriate for your supply voltage. Ensure that neither the mains adapter nor the cable are damaged. 1. Plug the adapter cable into the mains adapter socket 5 in the blood pressure monitor. 2. Plug the adapter plug into the wall socket. When the mains adapter is connected, no battery current is consumed.   5 EN 9. Error Messages 10. Safety, Care, Accuracy Test and Disposal If an error occurs during the measurement, the measurement is interrupted and an error message, e.g. «ERR 3», is displayed. Error Description Potential cause and remedy «ERR 1» Signal too The pulse signals on the cuff are too weak weak. Re-position the cuff and repeat the measurement.* «ERR 2» Error signal During the measurement, error signals BN were detected by the cuff, caused for instance by movement or muscle tension. Repeat the measurement, keeping your arm still. «ERR 3» No pressure An adequate pressure cannot be generBK in the cuff ated in the cuff. A leak may have occurred. Check that the cuff is correctly connected and is not too loose. Replace the batteries if necessary. Repeat the measurement. «ERR 5» Abnormal The measuring signals are inaccurate result and no result can therefore be displayed. Read through the checklist for performing reliable measurements and then repeat the measurement.* «ERR 6» MAM Mode There were too many errors during the measurement in MAM mode, making it impossible to obtain a final result. Read through the checklist for performing reliable measurements and then repeat the measurement.* «HI» Pulse or cuff The pressure in the cuff is too high (over pressure 299 mmHg) OR the pulse is too high too high (over 200 beats per minute). Relax for 5 minutes and repeat the measurement.* «LO» Pulse too The pulse is too low (less than 40 beats low per minute). Repeat the measurement.* * Please immediately consult your doctor, if this or any other problem occurs repeatedly. If you think the results are unusual, please read through the information in «Section 1.» carefully.  Safety and protection  6  Follow instructions for use. This document provides important product operation and safety information regarding this device. Please read this document thoroughly before using the device and keep for future reference.  This device may only be used for the purposes described in these instructions. The manufacturer cannot be held liable for damage caused by incorrect application.  This device comprises sensitive components and must be treated with caution. Observe the storage and operating conditions described in the «Technical Specifications» section.  Protect it from: - water and moisture - extreme temperatures - impact and dropping - contamination and dust - direct sunlight - heat and cold  The cuffs are sensitive and must be handled with care.  Do not exchange or use any other kind of cuff or cuff connector for measuring with this device.  Only pump up the cuff once fitted.  Do not use this device close to strong electromagnetic fields such as mobile telephones or radio installations. Keep a minimum distance of 3.3 m from such devices when using this device.  Do not use this device if you think it is damaged or notice anything unusual.  Never open this device.  If the device is not going to be used for a prolonged period the batteries should be removed.  Read the additional safety information provided within the individual sections of this instruction manual.  The measurement results given by this device is not a diagnosis. It is not replacing the need for the consultation of a physician, especially if not matching the patient’s symptoms. Do not rely on the measurement result only, always consider other potentially occurring symptoms and the patient’s feedback. Calling a doctor or an ambulance is advised if needed. Ensure that children do not use this device unsupervised; some parts are small enough to be swallowed. Be aware of the risk of strangulation in case this device is supplied with cables or tubes. Device care Clean the device only with a soft, dry cloth. Cleaning the cuff Carefully remove spots on the cuff with a damp cloth and soapsuds. WARNING: Do not wash the cuff in a washing machine or dishwasher!  Accuracy test We recommend this device is tested for accuracy every 2 years or after mechanical impact (e.g. being dropped). Please contact your local Microlife-Service to arrange the test (see foreword). Disposal Batteries and electronic devices must be disposed of in accordance with the locally applicable regulations, not with domestic waste. 11. Guarantee This device is covered by a 5 year guarantee from the date of purchase. During this guarantee period, at our discretion, Microlife will repair or replace the defective product free of charge. Opening or altering the device invalidates the guarantee. The following items are excluded from the guarantee:  Transport costs and risks of transport.  Damage caused by incorrect application or non-compliance with the instructions for use.  Damage caused by leaking batteries.  Damage caused by accident or misuse.  Packaging/storage material and instructions for use.  Regular checks and maintenance (calibration).  Accessories and wearing parts: Batteries, power adapter (optional). The cuff is covered by a functional guarantee (bladder tightness) for 2 years. Should guarantee service be required, please contact the dealer from where the product was purchased, or your local Microlife service. You may contact your local Microlife service through our website: www.microlife.com/support BP A3 Plus Compensation is limited to the value of the product. The guarantee will be granted if the complete product is returned with the original invoice. Repair or replacement within guarantee does not prolong or renew the guarantee period. The legal claims and rights of consumers are not limited by this guarantee. 12. Technical Specifications Operating conditions: 10 - 40 °C / 50 - 104 °F 15 - 95 % relative maximum humidity Storage conditions: -20 - +55 °C / -4 - +131 °F 15 - 95 % relative maximum humidity Weight: 368 g (including batteries) Dimensions: 143 x 85 x 58 mm Measuring procedure: oscillometric, corresponding to Korotkoff method: Phase I systolic, Phase V diastolic Measurement range: 20 - 280 mmHg – blood pressure 40 - 200 beats per minute – pulse Cuff pressure display range: 0 - 299 mmHg Resolution: 1 mmHg Static accuracy: pressure within ± 3 mmHg Pulse accuracy: ± 5 % of the readout value Voltage source: 4 x 1.5 V alkaline batteries; size AA Mains adapter DC 6V, 600 mA (optional) Battery lifetime: approx. 920 measurements (using new batteries) IP Class: IP20 Reference to EN 1060-1 /-3 /-4; IEC 60601-1; standards: IEC 60601-1-2 (EMC); IEC 60601-1-11 Expected service life: Device: 5 years or 10000 measurements Accessories: 2 years This device complies with the requirements of the Medical Device Directive 93/42/EEC. Technical alterations reserved. 7 EN Microlife BP A3 Plus 1 2 3 4 5 6 7 8 9 AT AK Botón ON/OFF (Encendido/Apagado) Pantalla Enchufe para manguito Compartimento de baterías Enchufe para adaptador de corriente Brazalete Conector del manguito Interruptor MAM Interruptor de cambio de usuario Botón M (Memoria) Botón Hora Pantalla AL Indicador de usuario AM Indicador de batería AN Fecha/Hora AO Valor sistólico AP Valor diastólico AQ Frecuencia del pulso AR Indicador de semáforo AS Tiempo de intervalo MAM BT Indicador del pulso BK Indicador de comprobación del manguito BL Modo MAM BM Símbolo de latidos irregulares (IHB) BN Indicador de movimiento del brazo BO Valor guardado Lea atentamente las instrucciones antes de utilizar este dispositivo. Pieza aplicada tipo BF Mantener en lugar seco 8 ES Uso previsto: Este monitor de presión arterial oscilométrico está diseñado para medir la presión arterial no invasiva en personas de 12 años o más. Está clínicamente validado en pacientes con hipertensión, hipotensión, diabetes, embarazo, preeclampsia, aterosclerosis, enfermedad renal en etapa terminal, obesidad y adultos mayores. Estimado cliente, Este dispositivo ha sido desarrollado en colaboración con médicos y su muy alta precisión ha sido probada en ensayos clínicos.* Si tiene cualquier pregunta o problema o si desea pedir piezas de recambio, no dude en contactar con su servicio de atención al cliente de Microlife local. Su distribuidor o farmacia podrá indicarle la dirección del distribuidor de Microlife en su país. También puede visitarnos en Internet en www.microlife.com donde encontrará información útil sobre nuestros productos. ¡Cuide su salud con Microlife AG! * Este dispositivo usa la misma tecnología de medición que el premiado modelo «BP 3BTO-A» probado de acuerdo con el protocolo de la Sociedad Británica e Irlandesa de Hipertensión (BIHS). Índice 1. Datos importantes acerca de la presión arterial y la automedición • ¿Cómo he de evaluar mi presión arterial? 2. Uso del dispositivo por primera vez • Colocar las baterías • Ajuste de fecha y hora • Elegir el manguito correcto • Seleccionar el usuario • Seleccionando el modo estándar o MAM • Modo MAM (altamente recomendado) 3. Medición de la presión arterial • Procedimiento para no guardar la lectura 4. Apariencia del símbolo de latidos irregulares (IHB) 5. Indicador de semáforo en la pantalla 6. Memoria de datos • Ver los valores guardados • Memoria llena • Borrar todos los valores 7. Indicador de baterías y cambio de baterías • Baterías con poca carga • Baterías descargadas – cambio • ¿Qué baterías y qué procedimiento? • Uso de baterías recargables 8. Uso de un adaptador de corriente 9. Mensajes de error 10. Seguridad, cuidado, control de precisión y eliminación de residuos • Seguridad y protección • Cuidado del dispositivo • Limpieza del brazalete • Control de precisión • Eliminación de residuos 11. Garantía 12. Especificaciones técnicas Tarjeta de garantía (véase reverso) BP A3 Plus 1. Datos importantes acerca de la presión arterial y la automedición  La presión arterial es la presión de la sangre que circula por las arterias, generada por el bombeo del corazón. Se miden siempre dos valores, el valor sistólico (superior) y el valor diastólico (inferior).  El dispositivo indica también la frecuencia del pulso (el número de latidos del corazón en un minuto).  ¡Una presión arterial permanentemente alta puede perjudicar su salud y debe ser tratada por su médico!  Consulte siempre con su médico los valores medidos y coméntele si ha notado algo inusual o si tiene alguna duda. No confíe nunca en una sola lectura de presión arterial.  Existen muchas causas de valores de presión arterial excesivamente altos. Su médico se las explicará en detalle y, en caso de necesidad, le ofrecerá el tratamiento adecuado. Además de la medicación, la pérdida de peso y el ejercicio físico también pueden disminuir la presión arterial.  Bajo ninguna circunstancia debe modificar las dosis de medicamentos o iniciar un tratamiento sin consultar a su médico  Dependiendo de la condición y el esfuerzo físico, la presión arterial está sujeta a amplias fluctuaciones durante el transcurso del día. ¡Por esta razón, debe realizar la medición siempre en las mismas condiciones de tranquilidad y estando relajado! Realice dos lecturas cada vez (por la mañana y por la noche) y haga una media de los resultados de las mediciones.  Es completamente normal que dos mediciones tomadas en rápida sucesión puedan producir resultados que difieran significativamente. Por ello recomendamos el uso de la tecnología MAM.  Las diferencias entre las mediciones tomadas por su médico o en la farmacia y las tomadas en casa son muy normales, debido a que estas situaciones son completamente diferentes.  Varias mediciones proporcionan información más fiable sobre la presión arterial que una sola medición. Por ello recomendamos el uso de la tecnología MAM.  Deje pasar un breve intervalo de tiempo de al menos 15 segundos entre dos mediciones.  Si sufre una arritmia cardíaca, consulte con su médico antes de usar el dispositivo. Consulte también el capítulo «Apariencia del símbolo de latidos irregulares (IHB)» de este manual del usuario.  ¡El indicador de pulsaciones no es apropiado para comprobar la frecuencia de los marcapasos! 9 ES  Si está embarazada, debe controlar su presión arterial con regularidad, ya que puede cambiar drásticamente durante este tiempo. Este monitor está especialmente probado para su uso en el embarazo y la preeclampsia. Cuando detecta altas lecturas inusuales en el embarazo, debe medir después de un tiempo breve (por ejemplo, 1 hora). Si la lectura es demasiado alta, consulte a su médico o ginecólogo.  ¿Cómo he de evaluar mi presión arterial? Tabla de clasificación de los valores de la presión arterial en adultos según las Normas Internacionales (ESH, ESC, JSH). Datos en mmHg. Nivel 1. presión arterial normal 2. presión arterial óptima 3. presión arterial elevada 4. presión arterial demasiado alta 5. presión arterial peligrosamente alta DiastóSistólico lico < 120 < 74 Recomendación Autocontrol 120 - 129 74 - 79 Autocontrol 130 - 134 80 - 84 Autocontrol 135 - 159 85 - 99 Acudir al médico ≥ 160 ¡Acudir urgentemente al médico! ≥ 100 El valor superior es el que determina la evaluación. Ejemplo: un valor de la presión arterial de 140/80 mm Hg o 130/90 mm Hg indica «presión arterial demasiado alta». 2. Uso del dispositivo por primera vez Colocar las baterías Después de desembalar el dispositivo, en primer lugar, inserte las baterías. El compartimento de las baterías 4 está en la parte inferior del dispositivo. Inserte las baterías (4 x 1,5 V, tamaño AA) de acuerdo con las marcas de polaridad indicadas. Ajuste de fecha y hora 1. Una vez activadas las baterías, el número del año parpadea en la pantalla. Ajuste el año pulsando el botón M AT. Para confirmarlo y ajustar a continuación el mes, pulse el botón Hora AK. 2. Ahora puede ajustar el mes usando el botón M. Pulse el botón Hora para confirmar y, a continuación, ajuste el día. 3. Por favor, siga las instrucciones anteriores para ajustar el día, la hora y los minutos. 4. Una vez que haya ajustado los minutos y pulsado el botón Hora, la fecha y la hora quedan establecidas y se visualiza la hora. 10 5. Si desea cambiar la fecha y la hora, pulse y mantenga pulsado el botón Hora durante aprox. 3 segundos hasta que comience a parpadear el número del año. Ahora, podrá introducir los nuevos valores tal como se ha descrito anteriormente. Elegir el manguito correcto Microlife ofrece diferentes tamaños de manguitos. Elija el tamaño de manguito adecuado según la circunferencia de su brazo (medida de forma ajustada en el centro del brazo). Tamaño de manguito para una circunferencia del brazo S 17 - 22 cm M 22 - 32 cm M-L 22 - 42 cm L 32 - 42 cm L - XL 32 - 52 cm Para un mejor ajuste y comodidad, hay manguitos preformados «Easy» disponibles. Use únicamente manguitos Microlife.  Contacte su servicio al cliente de Microlife local, si el manguito 6 incluido no es el adecuado para usted.  Conecte el manguito al dispositivo insertando el conector 7 del manguito en el enchufe 3 del manguito hasta que no entre más. Seleccionar el usuario Este dispositivo permite almacenar los resultados de 2 usuarios.  Antes de cada medición, seleccione con el interruptor de cambio de usuario 9 el usuario que desee: usuario 1 ó 2.  Usuario 1: deslice hacia arriba el interruptor de cambio de usuario 9 para seleccionar el icono de usuario 1.  Usuario 2: deslice hacia abajo el interruptor de cambio de usuario 9 para seleccionar el icono de usuario 2. La primera persona que realice la medición debe seleccionar usuario 1. Seleccionando el modo estándar o MAM Este dispositivo le permite seleccionar el modo estándar (medición sencilla estándar) o el modo MAM (medición triple automática). Para seleccionar el modo estándar, deslice el interruptor MAM 8 situado en la parte lateral del dispositivo hacia abajo a la posición «1», y para seleccionar el modo MAM, deslice el interruptor hacia arriba a la posición «3». Modo MAM (altamente recomendado)  En el modo MAM, se efectúan automáticamente 3 mediciones sucesivas y, después, se analiza y se visualiza automática-          mente el resultado. Debido a que la tensión arterial fluctúa constantemente, un resultado determinado de esta manera es más fiable que uno obtenido por una medición sencilla. Cando seleccione las 3 mediciones, el símbolo MAM BL aparecerá en la pantalla. En la parte inferior izquierda de la pantalla aparecen 1, 2 o 3 para indicar cuál de las 3 mediciones se está realizando en ese momento. Hay un descanso de 15 segundos entre las mediciones. Una cuenta regresiva indica el tiempo restante. Los resultados individuales no se visualizan. Su presión arterial sólo se visualizará una vez que se hayan efectuado las 3 mediciones. No retire el manguito entre las mediciones. Si una de las mediciones individuales ha sido dudosa, se toma automáticamente una cuarta. 3. Medición de la presión arterial Lista de chequeo para efectuar una medición fiable 1. Evite comer o fumar, así como cualquier otra actividad inmediatamente antes de la medición. 2. Siéntese en una silla con respaldo y relájese durante 5 minutos. Mantenga los pies planos sobre el piso y no cruce las piernas. 3. Efectúe la medición siempre en el mismo brazo (normalmente en el izquierdo). Es recomendable que su médico realice dos mediciones en cada brazo durante la primera visita para determinar de qué brazo se tomarán las mediciones en el futuro. Las mediciones se deben efectuar en el brazo con presión arterial más alta. 4. Quítese las prendas de vestir ajustadas a su brazo. Para evitar la constricción, no se deben arremangar las mangas de camisa, ya que no interfieren con el manguito si se encuentran en contacto con el brazo. 5. Asegúrese de utilizar el tamaño correcto del manguito (marcado en el manguito).  Coloque el manguito de tal forma que esté ajustado, pero que no quede demasiado apretado.  Asegúrese de que el manguito esté colocado 1-2 cm por encima del codo.  La marca de la arteria en el manguito (barra larga de 3 cm) debe descansar sobre la arteria que va en el lado interior del brazo.  Coloque el brazo de tal forma que esté relajado.  Asegúrese de que el manguito se encuentre a la misma altura que su corazón. BP A3 Plus 6. Presione el botón ON/OFF 1 para iniciar la medición. 7. Ahora, el manguito se inflará automáticamente. Relájese, no se mueva y no tense los músculos del brazo hasta que se visualice el resultado de la medición. Respire normalmente y no hable. 8. Una vez alcanzada la presión correcta, el inflado se detiene y la presión disminuye gradualmente. Si no se alcanzó la presión necesaria, el dispositivo bombeará automáticamente más aire al manguito. 9. Durante la medición, el indicador de pulso BT parpadea en la pantalla. 10.Se visualiza el resultado compuesto por la sistólica AO y el arterial diastólica AP y la frecuencia del pulso AQ. 11.Retire el manguito cuando la medición haya terminado. 12.Desconecte el dispositivo. (El tensiómetro se apaga automáticamente al cabo de aprox. 1 min). Procedimiento para no guardar la lectura Cuando la lectura aparezca en la pantalla mantenga pulsado el botón ON/OFF 1 hasta que «M» BO parpadee. Confirme que desea borrar la lectura pulsando el botón M AT. La medición se puede detener en cualquier momento presionando el botón ON/OFF (p. ej., si no se encuentra bien o en caso de tener una sensación de presión desagradable). Cuando se sabe que la presión arterial sistólica es muy alta, puede resultar ventajoso ajustar la presión individualmente. Pulse el botón ON/OFF una vez que el tensiómetro se haya inflado hasta un nivel de aprox. 30 mm Hg (representado en la pantalla). Mantenga pulsado el botón hasta que la presión esté aprox. 40 mm Hg por encima del valor sistólico esperado y entonces suelte el botón.   4. Apariencia del símbolo de latidos irregulares (IHB) Este símbolo BM indica que se detectó un latido cardíaco irregular. En este caso, la presión arterial medida puede diferir de sus valores reales de presión arterial. Se recomienda repetir la medición. Información para su doctor en caso de aparición repetida del símbolo IHB Este dispositivo es un monitor oscilométrico de presión arterial que también mide el pulso durante la medición de la presión arterial e indica cuándo el ritmo cardiaco es irregular. 11 ES 5. Indicador de semáforo en la pantalla 7. Indicador de baterías y cambio de baterías Las barras en el borde izquierdo de la pantalla AR muestran el rango de valores de la presión arterial. Dependiendo de la altura de la barra, el valor indicado es óptimo (verde), elevado (amarillo), demasiado alto (naranja) o peligrosamente alto (rojo). Esta clasificación se corresponde con los 4 rangos definidos por las normas internacionales (ESH, ESC, JSH) e indicados en la tabla del «Apartado 1.». Baterías con poca carga Cuando las baterías están gastadas aproximadamente ¾, el símbolo de baterías AM parpadea al momento de encender el dispositivo (se visualiza una batería parcialmente cargada). Aunque el dispositivo seguirá midiendo de manera fiable, tenga a mano baterías de recambio. Baterías descargadas – cambio Cuando las baterías están gastadas, el símbolo de baterías AM parpadea al momento de encender el dispositivo (se visualiza una batería descargada). Ya no se puede realizar ninguna medición y es preciso cambiar las baterías. 1. Abra el compartimento de baterías 4 situado en el fondo del dispositivo. 2. Sustituya las baterías; asegúrese de que la polaridad sea la correcta, tal como lo indican los signos en el compartimiento. 3. Para ajustar la fecha y la hora, siga el procedimiento descrito en el «Apartado 2.». La memoria retiene todos los valores, aunque haya que resetear la fecha y la hora; para este fin, el número del año parpadea automáticamente después de cambiar las baterías. 6. Memoria de datos Este dispositivo almacena automáticamente hasta 99 mediciones por cada usuario. Ver los valores guardados Seleccioné usuario 1 o 2 con el interruptor de cambio de usuario 9. Presione brevemente el botón M AT cuando el dispositivo esté apagado. En la pantalla aparecerá «M» BO y «A», cual representa el promedio de todos los valores almacenados. Al volver a pulsar el botón M se vuelve a visualizar el valor anterior. Pulsando el botón M repetidamente se puede cambiar de un valor guardado a otro. Memoria llena Asegúrese de que no exceder la capacidad máxima de 99 memorias de almacenamiento por usuario. Cuando la memoria está llena, el valor más antiguo es reemplazado por el valor número 100. Los valores deberán ser evaluados por un médico antes de alcanzar la capacidad máxima de la memoria - en caso contrario, se perderán los datos.  Borrar todos los valores Asegúrese que el usuario correcto está activado. 1. Con el dispositivo apagado, seleccione el usuario 1 ó 2 con el interruptor de cambio de usuario 9. 2. Mantenga pulsado el botón M AT hasta que en la pantalla aparezca «CL». Deje de pulsar el botón. 3. Mantenga pulsado el botón M mientras «CL» esté parpadeando para borrar permanente todos los valores del usuario seleccionado. Cancelar el borrado: pulse el botón ON/OFF 1 mientras «CL» esté parpadeando. No es posible borrar valores individuales.   12  ¿Qué baterías y qué procedimiento? Utilice 4 baterías alcalinas nuevas de tamaño AA, de 1,5 V, de larga duración. No utilice baterías caducadas. Si no va a usar el dispositivo durante un período prolongado, extraiga las baterías.    Uso de baterías recargables Este dispositivo también se puede usar con baterías recargables. Utilice únicamente baterías reutilizables del tipo «NiMH». Las baterías se deben extraer y recargar, cuando aparezca el símbolo de batería (batería descargada). No deben permanecer en el interior del dispositivo, ya que se pueden dañar (descarga total como resultado de un uso poco frecuente del dispositivo, incluso estando apagado). Retire siempre las baterías recargables si no va a usar el dispositivo en una semana o más. ¡Las baterías NO se pueden recargar dentro del tensiómetro! Recargue las baterías en un cargador externo y observe la información relativa a la recarga, el cuidado y a la duración.     8. Uso de un adaptador de corriente Este dispositivo se puede hacer funcionar utilizando el adaptador de corriente de Microlife (DC 6V, 600mA). Utilice únicamente el adaptador de corriente de Microlife disponible como accesorio original, apropiado para su voltaje de alimentación. Asegúrese de que no estén dañados ni el adaptador ni el cable. 1. Inserte el cable del adaptador en el enchufe para el adaptador de corriente 5 situado en el dispositivo. 2. Inserte la clavija del adaptador en una caja de enchufe. Mientras esté conectado el adaptador de corriente, no se consume corriente de las baterías.   9. Mensajes de error Si se produce un error durante la medición, esta se interrumpe y se visualiza un mensaje de error, p. ej., «ERR 3». Error Descripción Posible causa y solución «ERR 1» Señal dema- Las señales del pulso en el manguito siado débil son demasiado débiles. Vuelva a colocar el manguito y repita la medición.* «ERR 2» Señal de Durante la medición se han detectado error señales de error por el manguito, BN causadas, por ejemplo, por el movimiento o la contracción de un músculo. Repita la medición manteniendo el brazo quieto. «ERR 3» No hay No se puede generar una presión BK presión en adecuada en el manguito. Se puede el manguito haber producido una fuga. Compruebe que el manguito esté conectado correctamente y que no esté demasiado suelto. Cambie las baterías si fuese necesario. Repita la medición. «ERR 5» Resultado Las señales de medición son imprecisas y, anormal por ello, no se puede visualizar ningún resultado. Lea la lista de chequeo para efectuar mediciones fiables y repita la medición.* «ERR 6» Modo MAM Ha habido demasiados errores durante la medición en el modo MAM, por lo que es imposible obtener un resultado final. Lea la lista de chequeo para efectuar mediciones fiables y repita la medición.* BP A3 Plus Error «HI» Descripción Posible causa y solución La presión en el manguito es demasiado Pulso o presión de alta (superior a 299 mm Hg) o el pulso es demasiado alto (más de 200 latidos por manguito demasiado minuto). Relájese durante 5 minutos y repita la medición.* alto «LO» Pulso dema- El pulso es demasiado bajo (menos de 40 siado bajo latidos por minuto). Repita la medición.* * Por favor, consulte inmediatamente a su médico, si este o cualquier otro problema ocurre repetidamente. Si cree que los resultados son inusuales, por favor, lea detenidamente la información en el «Apartado 1.».  10. Seguridad, cuidado, control de precisión y eliminación de residuos  Seguridad y protección  Siga las instrucciones de uso. Este documento proporciona información importante de operación y seguridad del producto con respecto a este dispositivo. Lea atentamente este documento antes de usar el dispositivo y consérvelo para futuras consultas.  Este dispositivo sólo se debe utilizar para los propósitos descritos en estas instrucciones. El fabricante no se responsabiliza de ningún daño causado por un uso inadecuado.  El dispositivo está integrado por componentes sensibles y se debe tratar con cuidado. Respete las indicaciones de almacenamiento y funcionamiento que se describen en el apartado «Especificaciones técnicas».  Proteja el dispositivo de: - Agua y humedad. - Temperaturas extremas. - Impactos y caídas. - Contaminación y polvo. - Luz directa del sol. - Calor y frío.  Los brazaletes son sensibles y deben tratarse cuidadosamente.  No intercambie ni utilice ningún otro tipo de manguito o conector del manguito con este dispositivo.  Infle el manguito únicamente cuando está colocado correctamente en el brazo.  No use el dispositivo cerca de fuertes campos eléctricos tales como teléfonos móviles o equipos de radio. Mantenga el dispo13 ES      sitivo a una distancia mínima de 3,3 m de estos aparatos cuando lo utilice. No utilice el dispositivo si cree que puede estar roto o detecta alguna anomalía. Nunca abra el dispositivo. Si no va a utilizar el dispositivo durante un periodo largo de tiempo, extraiga las baterías. Lea las instrucciones de seguridad adicionales en los dispositivos individuales de este manual. El resultado de medición dado por este dispositivo no es un diagnóstico. No está reemplazando la necesidad para la consulta de un médico, especialmente si no coincide con los síntomas del paciente. No confíe sólo en el resultado de la medición, considere siempre otros síntomas potencialmente presentes y la retroalimentación del paciente. Se aconseja llamar a un médico o una ambulancia si es necesario. Asegúrese de que los niños no utilicen el dispositivo sin supervisión, puesto que podrían tragarse algunas de las piezas más pequeñas. Tenga en cuenta el riesgo de estrangulamiento en caso de que este dispositivo se suministre con cables o tubos. Cuidado del dispositivo Limpie el dispositivo únicamente con un paño suave y seco. Limpieza del brazalete Para limpiar el manguito hágalo cuidadosamente con un paño húmedo y jabón neutro. ATENCIÓN: ¡No lave el brazalete en la lavadora!  Control de precisión Recomendamos someter este dispositivo a un control de precisión cada 2 años o después de un impacto mecánico (p. ej., si se ha caído). Por favor, contacte su servicio al cliente Microlife local para concertar la revisión (ver introducción). Eliminación de residuos Las baterías y los dispositivos electrónicos se deben eliminar según indique la normativa local pertinente y no se deben desechar junto con la basura doméstica. 11. Garantía Este dispositivo tiene una garantía de 5 años a partir de la fecha de compra. Durante este período de garantía, a nuestra discre14 ción, Microlife reparará o reemplazará el producto defectuoso de forma gratuita. La garantía no será válida si abre o manipula el dispositivo. Los siguientes artículos están excluidos de la garantía:  Costos de transporte y riesgos del transporte.  Daños causados por la aplicación incorrecta o el incumplimiento de las instrucciones de uso.  Daño causado por fugas de baterías.  Daño causado por accidente o mal uso.  Material de embalaje / almacenamiento e instrucciones de uso.  Comprobaciones periódicas y mantenimiento (calibración).  Accesorios y piezas de desgaste: Baterías, adaptador de corriente (opcional). El brazalete está cubierto por una garantía funcional (estanqueidad de la vejiga) durante 2 años. En caso de que se requiera un servicio de garantía, comuníquese con el distribuidor donde adquirió el producto o con su servicio local de Microlife. Puede ponerse en contacto con su servicio local Microlife a través de nuestro sitio web: www.microlife.com/support La compensación se limita al valor del producto. La garantía se otorgará si el producto completo se devuelve con la factura original. La reparación o el reemplazo dentro de la garantía no prolonga ni renueva el período de garantía. Los reclamos y derechos legales de los consumidores no están limitados por esta garantía. 12. Especificaciones técnicas Condiciones de funcionamiento: Condiciones de almacenamiento: Peso: Tamaño: Procedimiento de medición: Nivel de medición: 10 - 40 °C / 50 - 104 °F 15 - 95% de humedad relativa máxima -20 - +55 °C / -4 - +131 °F 15 - 95% de humedad relativa máxima 368 g (incluyendo baterías) 143 x 85 x 58 mm oscilométrico, según el método Korotkoff: Fase I sistólica, fase V diastólica 20 - 280 mm Hg – presión arterial 40 - 200 latidos por minuto – pulso Intervalo de indicación de la presión del manguito: 0 - 299 mm Hg Resolución: Precisión estática: Precisión del pulso: Fuente de corriente: 1 mm Hg presión dentro de ± 3 mm Hg ± 5% del valor medido 4 baterías alcalinas 1,5 V; tamaño AA Adaptador de voltaje c.a. 6V, 600 mA (opcional) Duración de la batería: aprox. 920 mediciones (usando baterías nuevas) Clase IP: IP20 Referencia a los EN 1060-1 /-3 /-4; IEC 60601-1; estándares: IEC 60601-1-2 (EMC); IEC 60601-1-11 Vida útil esperada: Dispositivo: 5 años o 10.000 mediciones Accesorios: 2 años Este dispositivo esta en conformidad con los requerimientos de la Directiva 93/42/CEE relativa a productos sanitarios. Reservado el derecho a realizar modificaciones técnicas. BP A3 Plus 15 ES Microlife BP A3 Plus 1 2 3 4 5 6 7 8 9 AT AK Bouton ON/OFF (marche/arrêt) Écran Prise pour brassard Compartiment à piles Prise pour adaptateur secteur Brassard Connecteur brassard Sélecteur MAM L'interrupteur de sélectionner l'utilisateur Bouton M (mémoire) Bouton de réglage du temps Écran AL Indicateur utilisateur AM Indicateur d'état de charge des piles AN Date/Heure AO Tension systolique AP Tension diastolique AQ Fréquence des battements cardiaques AR Indicateur de classification de mesure AS Intervalle de temps MAM BT Indicateur de pouls BK Indicateur de brassard BL Mode MAM BM (IHB) symbole de rythme cardiaque irrégulier BN Indicateur de mouvement de bras BO Indicateur de mise en mémoire Veuillez lire attentivement les instructions avant d'utiliser ce produit. Partie appliquée du type BF A conserver dans un endroit sec 16 FR Utilisation: Ce tensiomètre oscillométrique est conçu pour mesurer la pression artérielle de manière non invasive chez les personnes âgées de 12 ans et plus. Il est validé cliniquement chez les patients souffrant d'hypertension, d'hypotension, de diabète, de grossesse, de pré-éclampsie, d'athérosclérose, d'insuffisance rénale terminale, d'obésité ainsi que pour les personnes âgées. Cher client, Cet appareil a été développé en collaboration avec des médecins. Les tests cliniques dont il a fait l'objet ont montré que les résultats affichés sont d'une très grande précision.* Si vous avez des questions, des problèmes ou désirez commander des pièces détachées, veuillez contacter votre Service Clients Microlife local. Adressez-vous à votre revendeur ou à la pharmacie où vous avez acheté l'appareil pour avoir les coordonnées du représentant Microlife de votre pays. Vous pouvez aussi visiter notre site Internet à l'adresse www.microlife.com, où vous trouverez de nombreuses et précieuses informations sur nos produits. Restez en bonne santé avec Microlife AG. * Cet appareil applique la même technologie de mesure que le modèle primé «BP 3BTO-A» testé conformément aux standards de la Société Britannique et Irlandaise de l'Hypertension (BIHS). Sommaire 1. Informations importantes sur la tension et l'auto-mesure • Comment puis-je évaluer ma tension? 2. Première mise en service de l'appareil • Insertion des piles • Réglage de la date et de l'heure • Sélection du brassard correct • Choix de l'utilisateur • Sélection du mode standard ou MAM • Mode MAM (hautement recommandé) 3. Prise de tension • Comment ne pas enregistrer une lecture 4. Apparition du symbole de rythme cardiaque irrégulier (IHB) 5. Affichage de l'indicateur de classification de mesure 6. Mémoire • Visualisation des valeurs enregistrées • Mémoire saturée • Suppression de toutes les valeurs 7. Indicateur d'état de charge des piles et de remplacement • Piles presque déchargées • Piles déchargées – remplacement • Types de pile et procédure • Utilisation de piles rechargeables 8. Utilisation d'un adaptateur secteur 9. Messages d'erreurs 10. Sécurité, entretien, test de précision et élimination de l'équipement • Sécurité et protection • Entretien de l'appareil • Nettoyage du brassard • Test de précision • Élimination de l'équipement 11. Garantie 12. Caractéristiques techniques Carte de garantie (voir verso) BP A3 Plus 1. Informations importantes sur la tension et l'automesure  La tension est la pression du sang qui circule dans les artères sous l'effet du pompage du coeur. Deux valeurs, la tension systolique (valeur la plus haute) et la tension diastolique (valeur la plus basse), sont toujours mesurées.  L'appareil indique aussi le pouls (nombre de battements du coeur par minute).  Une tension élevée en permanence peut nuire à votre santé et nécessite un traitement. Veuillez consulter votre médecin.  Signalez toujours la tension relevée à votre médecin et faiteslui part de toute observation inhabituelle ou de vos doutes. Ne vous basez jamais sur une seule prise de tension.  De nombreux facteurs peuvent provoquer une tension trop élevée. Votre médecin pourra vous fournir des explications plus détaillées à ce sujet et vous prescrire un traitement approprié. Outre les médicaments, exercice et perdre du poids peuvent également abaisser votre tension artérielle.  En aucun cas vous ne devez modifier vos doses de médicaments ou initier un traitement sans consulter votre médecin.  La tension varie fortement au cours de la journée selon les efforts physiques et l'état. Vous devriez de ce fait toujours effectuer les mesures dans les mêmes conditions, au calme, quand vous sentez détendu! Chaque jour, prendre au moins 2 mesures le matin et 2 mesures le soir puis calculer la moyenne des résultats obtenus.  Il est courant que deux mesures effectuées l'une à la suite de l'autre fournissent des résultats très différents. C'est pourquoi nous recommandons d'utiliser la technologie MAM.  Il n'est pas non plus inhabituel de constater des écarts entre les mesures prises par le médecin ou à la pharmacie et celles que vous effectuez à la maison puisque les environnements sont très différents.  Plusieurs mesures fournissent des informations plus fiables sur votre tension artérielle qu'une seule mesure. C'est pourquoi nous recommandons d'utiliser la technologie MAM.  Observez une pause d'au moins 15 secondes entre deux mesures.  Si vous souffrez d'une arythmie cardiaque, consultez votre médecin avant d'utiliser l'appareil. Voir également le chapitre «Apparition du symbole de rythme cardiaque irrégulier (IHB)» de ce manuel d'utilisation. 17 FR  L’affichage du pouls ne permet pas de contrôler la fréquence des stimulateurs cardiaques.  Si vous êtes enceinte, vous devriez surveiller régulièrement votre tension artérielle car elle peut changer drastiquement durant cette période. Ce tensiometre a été spécialement testé pour une utilisation pendant la grossesse et la prééclampsie. Lorsque vous obtenez des mesures élevées inhabituelles au cours de la grossesse, il est conseillé de refaire une mesure après un petit moment (par exemple 1 heure). Si la mesure est encore trop élevée, consultez votre médecin ou votre gynécologue.  Comment puis-je évaluer ma tension? Tableau de classification des tensions arterielles chez les adultes, conformément aux directives internationales (ESH, ESC, JSH). Données en mmHg. Plage 1. Tension normale Systolique < 120 Diastolique < 74 2. Tension optimale 120 - 129 74 - 79 3. Tension élevée 130 - 134 80 - 84 4. Tension trop haute 135 - 159 85 - 99 5. Tension dangereu- ≥ 160 sement haute ≥ 100 Recommandation Contrôle personnel Contrôle personnel Contrôle personnel Consultation médicale Consultation médicale immédiate! La valeur la plus haute est déterminante pour l'évaluation. Exemple: une tension artérielle valeur 140/80 mmHg ou la valeur 130/90 mmHg indique une «tension trop haute». 2. Première mise en service de l'appareil Insertion des piles Après avoir déballé votre appareil, insérez d'abord les piles. Le compartiment à piles 4 se trouve sur le dessous de l'appareil. Insérez les piles (4 x 1,5 V, format AA) en respectant les indications de polarité. 18 Réglage de la date et de l'heure 1. Après l'insertion de nouvelles piles, les chiffres de l'année clignotent sur l'écran. Vous pouvez régler l'année en appuyant sur le bouton M AT. Pour confirmer et régler le mois, pressez le bouton de réglage du temps AK. 2. Vous pouvez maintenant régler le mois en appuyant sur le bouton M. Pour confirmer, pressez le bouton de réglage du temps puis réglez le jour. 3. Veuillez suivre les instructions ci-dessus pour régler le jour, l'heure et les minutes. 4. Après la définition des minutes et la pression du bouton de réglage du temps, la date et l'heure réglées s'afficheront. 5. Pour changer la date et l'heure, pressez le bouton de réglage du temps environ 3 secondes jusqu'à ce que les chiffres de l'année clignotent. Vous pouvez alors saisir les nouvelles valeurs comme décrit ci-dessus. Sélection du brassard correct Microlife offre différentes tailles de brassard. Sélectionnez la taille qui correspond à la circonférence du haut du bras (mesurée en tendant le brassard autour du haut du bras dans la partie centrale). Taille du brassard pour la circonférence du haut du bras S 17 - 22 cm M 22 - 32 cm M-L 22 - 42 cm L 32 - 42 cm L - XL 32 - 52 cm Des brassards préformés «Easy» sont disponibles en option pour un meilleur confort et utilisation. Utilisez exclusivement des brassards Microlife.  Adressez-vous à votre Service Microlife local si le brassard 6 fourni ne convient pas.  Raccordez le brassard à l'appareil en enfichant le connecteur 7 dans la prise 3 aussi loin que possible.   Choix de l'utilisateur Cet appareil permet l'enregistrement des mesures pour 2 utilisateurs.  Avant chaque mesure, régler l'interrupteur de sélection pour l'utilisateur 9 recherché 1 ou 2.  Utilisateur 1: réglez l'interrupteur 9 vers le haut l'icône 1.  Utilisateur 2: réglez l'interrupteur 9 vers le bas l'icône 2. La première personne à utiliser l'appareil devrait choisir utilisateur 1.  Sélection du mode standard ou MAM Cet appareil vous permet de choisir le mode standard (mesure standard simple) ou le mode MAM (mesure triple automatique). Pour choisir le mode standard, poussez le sélecteur MAM 8 sur le côté de l'appareil vers le bas, en position «1». Pour activer le mode MAM, poussez ce sélecteur vers le haut, en position «3». Mode MAM (hautement recommandé)  En mode MAM, 3 mesures sont réalisées l'une à la suite de l'autre et le résultat est analysé par l'appareil puis affiché. Comme la tension varie sans cesse, un résultat déterminé de cette façon est plus fiable qu'un résultat obtenu avec une mesure simple.  Quand vous sélectionnez le mode 3 mesures, le symbole MAM BL apparaît à l'écran.  La partie droite inférieure de l'écran signale le numéro des 3 mesures réalisées au moyen des chiffres 1, 2 et 3.  Il y a une pause de 15 secondes entre les mesures. Un compte à rebours indique le temps restant.  Les résultats individuels ne s'affichent pas. Votre tension n'apparaîtra sur l'écran qu'après la réalisation des 3 mesures.  N'enlevez pas le brassard entre les mesures.  Si l'appareil juge l'une des mesures de la série non plausible, il en effectuera une quatrième. 3. Prise de tension Pré-requis pour une mesure fiable 1. Évitez d'effectuer des efforts physiques, de manger ou de fumer directement avant la prise de tension. 2. Asseyez-vous sur une chaise à dossier et détendez-vous pendant 5 minutes. Gardez les pieds à plat sur le sol et ne croisez pas les jambes. 3. Prenez toujours la tension sur le même bras (normalement à gauche). Il est recommandé que les médecins prennent, lors de la première visite, des mesures aux deux bras afin de définir le bras de référence. Le bras avec la plus haute tension artérielle doit être mesuré. 4. Enlevez les vêtements serrés du haut du bras. Pour éviter une constriction, n'enroulez pas les manches en les remontant - elles n'interfèrent pas avec le brassard quand elles restent à plat. 5. Assurez vous toujours que la taille du brassard correspond bien à la circonférence du bras (en impression sur le brassard).  Placez puis fermez le brassard sans trop le serrer. BP A3 Plus  Vérifiez que le brassard est positionné 1-2 cm au dessus de la pliure du coude.  L’artère représentée sur le brassard (barre d’environ 3 cm) doit être centrée exactement sur l’artère qui parcourt la partie interne du bras.  Placez votre bras sur un support pour qu'il soit détendu.  Vérifiez que le brassard est au même niveau que votre cœur. 6. Pressez le bouton ON/OFF 1 pour démarrer la mesure. 7. Le brassard commence à se gonfler. Essayez d'être détendu. Ne bougez pas et ne faites pas travailler les muscles de votre bras avant l'affichage du résultat. Respirez normalement et évitez de parler. 8. Une fois que le brassard a atteint la pression correcte, le gonflage s'arrête et la pression diminue progressivement. Si la bonne pression n'est pas atteinte, l'appareil pompera plus d'air dans le brassard. 9. Pendant la mesure, l'indicateur de pouls BT clignote sur l'écran. 10.Le résultat, formé de la tension systolique AO, de la tension diastolique AP et du pouls, AQ s'affiche. Reportez-vous aussi aux explications données sur d'autres affichages dans ce manuel. 11.Une fois la mesure prise, enlevez le brassard. 12.Mettez l'appareil hors tension. (Le tensiomètre se met hors tension tout seul au bout de 1 min. environ). Comment ne pas enregistrer une lecture Aussitôt que le résultat apparaît à l’écran, appuyer et maintenir le bouton ON/OFF 1 jusqu’à ce que «M» BO clignote. Confirmer pour supprimer la mesure en appuyant sur le bouton M AT. Vous pouvez arrêter la mesure à tout moment en pressant le bouton ON/OFF (par ex. si vous n'êtes pas à l'aise ou sentez une pression désagréable). Si vous savez que votre tension artérielle systolique est très élevée, il peut être préférable pour vous de définir la tension individuellement. Pressez le bouton ON/OFF après avoir gonflé le tensiomètre à environ 30 mmHg (montré sur l'écran). Maintenez le bouton enfoncé jusqu'à ce que la tension dépasse d'environ 40 mmHg la valeur systolique attendue. Relâchez alors le bouton.   4. Apparition du symbole de rythme cardiaque irrégulier (IHB) Ce symbole BM indique qu'un rythme cardiaque irrégulier a été détecté. Dans ce cas, la pression artérielle mesurée peut s'écarter 19 FR de vos valeurs réelles de tension artérielle. Il est recommandé de refaire une mesure de tension. Information destinée au médecin en cas d'apparition régulière du symbole IHB sur l'écran. Cet appareil mesure la pression artérielle selon une méthode oscillométrique. Pendant la mesure de la pression artérielle, il analyse également le pouls et indique si la fréquence cardiaque est irrégulière. 5. Affichage de l'indicateur de classification de mesure Les rectangles situés sur le bord gauche de l'écran AR vous indiquent dans quelle fourchette votre résultat se trouve. Selon la hauteur du rectangle, la valeur d'affichage est soit à l'intérieur de l'optimum (vert), élevée (jaune), trop haute (orange) ou dangereusement haute gamme (rouge). Cette classification correspond à 4 plages définies par les directives internationales (ESH, ESC, JSH), comme décrit dans la «section 1.». 6. Mémoire L'appareil enregistre automatiquement jusqu'à 99 mesures pour chacun des 2 utilisateurs. Visualisation des valeurs enregistrées Sélectionner l'utilisateur 1 ou 2 avec l'interrupteur 9. Pressez le bouton M AT brièvement quand l’appareil est hors tension. L'écran affiche d'abord «M» BO et «A», qui représente la moyenne de toutes les mesures mémorisées. Une nouvelle pression du bouton M réaffiche la valeur précédente. Une pression répétée du bouton M vous permet de naviguer entre les valeurs enregistrées. Mémoire saturée Veuillez noter que la capacité d'enregistrement est de 99 mémoires par utilisateur et ne peut aller au delà. Une fois que la mémoire est pleine, le résultat le plus ancien sera remplacé par la nouvelle (100) mesure. Les valeurs doivent être évaluées par un médecin avant que la capacité maximale de mémoire ne soit atteinte – sinon les données seront perdues. Suppression de toutes les valeurs Vérifier que le bon utilisateur a été bien sélectionné. 1. Sélectionner l'utilisateur 1 ou 2 avec l'interrupteur de sélectionner l'utilisateur 9, lorsque l'appareil est éteint.  20 2. Maintenez appuyer le bouton M AT jusqu'à ce que «CL» clignote à l'écran, puis relâchez le bouton M. 3. Appuyez sur le bouton M pendant que «CL» clignote pour effacer définitivement toutes les valeurs de l'utilisateur sélectionné. Annuler suppression: appuyez sur le bouton ON/OFF 1 pendant que «CL» clignote. Il est impossible d'effacer des valeurs individuelles.   7. Indicateur d'état de charge des piles et de remplacement Piles presque déchargées Quand les piles sont usées aux ¾ environ, le symbole AM clignotera dès la mise sous tension de l'appareil (affichage d'une pile à moitié remplie). Bien que l'appareil continue à effectuer des mesures fiables, vous devriez remplacer les piles le plus tôt possible. Piles déchargées – remplacement Quand les piles sont déchargées, le symbole AM clignotera dès la mise sous tension de l'appareil (affichage d'une pile déchargée). Il vous est impossible de prendre d'autres mesures et vous devez remplacer les piles. 1. Ouvrez le compartiment à piles 4 sur le dessous de l'appareil. 2. Remplacez les piles – assurez-vous de la bonne polarité en vous basant sur les symboles placés dans le logement. 3. Pour régler la date et l'heure, suivez la procédure décrite à la «section 2.». La mémoire conserve les valeurs enregistrées mais la date et l'heure doivent être redéfinies – les chiffres de l'année clignotent automatiquement après le remplacement des piles. Types de pile et procédure Utiliser 4 nouvelles piles alcalines de 1,5 V, longue durée, format AA. N'utilisez pas les piles au-delà de leur date de péremption. Si vous ne comptez pas utiliser l'appareil pendant une période prolongée, prenez soin de retirer les piles. Utilisation de piles rechargeables Vous pouvez aussi faire fonctionner cet appareil avec des piles rechargeables. Veillez à n'utiliser que des piles rechargeables du type «NiMH». Veillez à retirer et à recharger les piles quand le symbole d'usure (pile déchargée) apparaît. Ne laissez pas les piles à l'intérieur de l'appareil. Elles pourraient s'endommager (décharge totale par inactivité prolongée de l'appareil, même s'il est hors tension).         Retirez toujours les piles rechargeables si vous n'avez pas l'intention d'utiliser l'appareil pendant une semaine ou plus. Il est IMPOSSIBLE de charger les piles quand elles sont à l'intérieur du tensiomètre. Rechargez ces piles dans un chargeur externe et observez les instructions relatives à la charge, à l'entretien et à la durée de vie. 8. Utilisation d'un adaptateur secteur Vous pouvez faire marcher cet appareil à l'aide d'un adaptateur secteur Microlife (DC 6V, 600 mA). Utilisez seulement l'adaptateur Microlife disponible comme accessoire original pour l'alimentation électrique. Veillez à ce que ni l'adaptateur secteur ni le câble ne soient endommagés. 1. Enfichez le câble d'alimentation dans la prise pour l'adaptateur secteur 5 sur le tensiomètre. 2. Branchez le connecteur de l'adaptateur secteur sur la prise de courant murale. Quand l'adaptateur secteur est raccordé, les piles ne sont pas sollicitées.   9. Messages d'erreurs Si une erreur se produit durant la mesure, celle-ci est interrompue et un message d'erreur, par ex. «ERR 3», s'affiche. Erreur Description Cause(s) possible(s) et solution «ERR 1» Signal trop Les signaux de pulsation sur le brassard faible sont trop faibles. Repositionnez le brassard et répétez la mesure.* «ERR 2» Signal Pendant la mesure, des signaux incorBN incorrect rects ont été détectés par le brassard suite à des mouvements du bras ou à un effort musculaire. Répétez la mesure sans bouger votre bras. Le brassard ne se gonfle pas à la pression «ERR 3» Pas de requise. Des fuites peuvent s'être produites. BK pression Vérifiez si le brassard est bien raccordé et dans le suffisamment serré. Remplacez les piles si brassard nécessaire. Répétez la mesure. «ERR 5» Résultat Les signaux de mesure sont inexacts et anormal aucun résultat de mesure ne s'affiche de ce fait. Lisez la liste de contrôle pour l'exécution de mesures fiables, puis répétez la mesure.* Erreur Description Cause(s) possible(s) et solution «ERR 6» Mode MAM Trop d'erreurs pendant la mesure en mode MAM, ce qui empêche l'obtention d'un résultat final. Lisez la liste de contrôle pour l'exécution de mesures fiables, puis répétez la mesure.* «HI» Pouls ou La pression du brassard est trop élevée pression de (plus de 299 mmHg) OU le pouls est trop brassard haut (plus de 200 battements par trop élevé minute). Reposez-vous 5 minutes, puis répétez la mesure.* «LO» Pouls trop Le pouls est trop bas (moins de 40 battebas ments par minute). Répétez la mesure.* * Veuillez consulter immédiatement votre médecin si cela ou tout autre problème se produit à plusieurs reprises. Si vous obtenez des résultats que vous jugez inhabituels, veuillez lire attentivement les indications de la «section 1.».  10. Sécurité, entretien, test de précision et élimination de l'équipement Sécurité et protection   Respectez les instructions d’utilisation. Ce document fournit des       BP A3 Plus informations importantes sur le fonctionnement et la sécurité de cet appareil. Veuillez lire attentivement ce document avant d'utiliser l'appareil et conservez-le pour vous y référer ultérieurement. Cet appareil est réservé aux applications décrites dans ce manuel. Le fabricant ne peut être tenu pour responsable de dommages provoqués par une utilisation incorrecte. Cet appareil comprend des éléments sensibles et doit être traité avec précaution. Respectez les conditions de stockage et d'emploi indiquées à la section «Caractéristiques techniques». Il convient de le protéger contre: - l'eau et l'humidité - les températures extrêmes - les chocs et chutes - les saletés et la poussière - les rayons solaires directs - la chaleur et le froid Les brassards sont des éléments sensibles qui requièrent des précautions. Ne pas utiliser un brassard ou connecteur autre que celui fourni par Microlife. Ne gonflez le brassard qu'après l'avoir ajusté autour du bras. 21 FR  Ne mettez pas l'appareil en service dans un champ électromagnétique de grande intensité, par exemple à proximité de téléphones portables ou d'installations radio. Garder une distance minimale de 3,3 mètres de ces appareils lors de toute utilisation.  N'utilisez pas l'appareil si vous pensez qu'il est endommagé ou remarquez quelque chose de particulier.  N'ouvrez jamais l'appareil.  Si vous comptez ne pas utiliser l'appareil pendant une période prolongée, prenez soin de retirer les piles.  Lisez attentivement les indications de sécurité mentionnées dans les différentes sections de ce mode d'emploi.  La mesure délivrée par cet appareil ne constitue pas un diagnostic. Il ne remplace pas la nécessité d'une consultation médicale, surtout si elle ne correspond pas aux symptômes du patient. Ne comptez pas uniquement sur le résultat de la mesure, considérez toujours d'autres symptômes pouvant survenir et le ressenti du patient. Il est conseillé d'appeler un médecin ou une ambulance si nécessaire. Ne laissez jamais les enfants utiliser l'appareil sans surveillance. Certaines de ses parties sont si petites qu'elles peuvent être avalées. Possible risque d’étranglement dans le cas où l’appareil est fourni avec des câbles ou des tuyaux. Entretien de l'appareil Utilisez exclusivement un chiffon sec et doux pour nettoyer l'appareil. Nettoyage du brassard Nettoyer le brassard avec précaution à l'aide d'un chiffon humide et de l'eau savonneuse. AVERTISSEMENT: Ne pas laver le brassard en machine ou au lave vaisselle! Test de précision Nous recommandons de faire contrôler la précision de cet appareil tous les 2 ans ou après un choc mécanique (par ex. chute). Veuillez-vous adresser à votre Service Microlife local pour convenir d'une date (voir avant-propos). Élimination de l'équipement Les piles et appareils électroniques doivent être éliminés en conformité avec les prescriptions locales, séparément des ordures ménagères.  22 11. Garantie Cet appareil est couvert par une garantie de 5 ans à compter de la date d'achat. Pendant cette période de garantie, à notre discrétion, Microlife réparera ou remplacera sans frais le produit défectueux. Le fait d'ouvrir ou de modifier l'appareil invalide la garantie. Sont exclus de la garantie, les cas suivants:  Frais de transport et risques de transport.  Dommages causés par une utilisation incorrecte ou le nonrespect du mode d'emploi.  Dommages causés par une fuite des piles.  Dommages causés par un accident ou une mauvaise utilisation.  Matériel d'emballage / stockage et mode d'emploi.  Contrôles et maintenance réguliers (étalonnage).  Accessoires et pièces d'usure: Piles, adaptateur secteur (en option). Le brassard est couvert par une garantie de fonctionnement de 2 ans. Pour toute demande de garantie, veuillez contacter le revendeur auprès duquel le produit a été acheté ou le bureau local Microlife. Vous pouvez également nous joindre via notre site Internet: www.microlife.com/support L'indemnisation est limitée à la valeur du produit. La garantie peut être accordée que si le produit est retourné complet avec la facture d'origine. La réparation ou le remplacement sous garantie ne prolonge ni ne renouvelle la période de garantie. Les prétentions légales et droits des consommateurs ne sont pas limités par cette garantie. 12. Caractéristiques techniques Conditions 10 - 40 °C / 50 - 104 °F d’utilisation: Humidité relative 30 - 85 % max. Conditions de -20 - +55 °C / -4 - +131 °F stockage: Humidité relative 30 - 85 % max. Poids: 368 g (piles incluses) Dimensions: 143 x 85 x 58 mm Procédure de mesure: Oscillométrique, conforme à la méthode Korotkoff: phase I systolique, phase V diastolique Plage de mesure: 20 - 280 mmHg – tension 40 - 200 battements par minute – pouls Plage de pression affichée du brassard: 0 - 299 mmHg Résolution: 1 mmHg Précision statique: Plage d'incertitude ± 3 mmHg Précision du pouls: ± 5 % de la valeur lue Alimentation 4 x piles alcalines de 1,5 V; format AA électrique: Adaptateur secteur DC-AC 6 V 600 mA (en option) Durée de vie des piles: env. 920 mesures (avec des piles neuves) Classe IP: IP20 Référence aux EN 1060-1 /-3 /-4; IEC 60601-1; normes: IEC 60601-1-2 (EMC); IEC 60601-1-11 Espérance de Appareil: 5 ans ou 10’000 mesures fonctionnement: Accessoires: 2 ans Cet appareil est conforme aux exigences de la directive relative aux appareils médicaux 93/42/EEC. Sous réserve de modifications techniques. BP A3 Plus 23 FR Microlife BP A3 Plus 1 2 3 4 5 6 7 8 9 AT AK Tasto ON/OFF Display Presa bracciale Vano batterie Foro di alimentazione per il trasformatore Bracciale Raccordo bracciale Selettore MAM Selettore utente (user) Tasto M (memoria) Tasto ora Display AL Indicatore utente AM Livello di carica delle batterie AN Data/ora AO Pressione sistolica (massima) AP Pressione diastolica (minima) AQ Frequenza cardiaca AR Classificatore della pressione arteriosa AS Intervallo di tempo MAM BT Indicatore di pulsazioni BK Indicatore di funzionamento del bracciale BL Modalità MAM BM Simbolo di Battito Irregolare (IHB) BN Indicatore di movimento del braccio BO Misurazioni memorizzate Leggere attentamente le istruzioni prima di usare questo dispositivo. Parte applicata tipo BF Conservare in luogo asciutto 24 IT Destinazione d’uso Questo misuratore di pressione oscillometrico è destinato alla misurazione non invasiva della pressione arteriosa nelle persone oltre i 12 anni di età. È clinicamente validato per pazienti con ipertensione, ipotensione, diabete, arteriosclerosi, insufficienza renale allo stadio terminale, pre-eclampsia, in gravidanza, per gli obesi e gli anziani. Gentile cliente, questo dispositivo è stato sviluppato in collaborazione con i medici e test clinici hanno provato che la precisione della misurazione della pressione è molto elevata.* In caso di domande, problemi o per ordinare parti di ricambio, contattare il proprio rivenditore di fiducia o il locale servizio clienti di Microlife. In alternativa è possibile visitare il sito www.microlife.it che offre moltissime informazioni utili sui nostri prodotti. Rimanete in salute – Microlife AG! * Questo dispositivo usa la stessa tecnologia di misurazione del modello «BP 3BTO-A», premiato per la sua precisione e testato in base al protocollo della British and Irish Hypertension Society (BIHS). Indice 1. Informazioni importanti sulla pressione arteriosa e l'automisurazione • Come valutare la propria pressione arteriosa 2. Utilizzo del dispositivo per la prima volta • Inserimento delle batterie • Impostazione data e ora • Selezione del bracciale adatto • Selezione dell'utente • Selezionare la modalità standard o MAM • Modalità MAM (altamente raccomandata) 3. Misurazione della pressione arteriosa • Come non memorizzare una misurazione 4. Comparsa del simbolo di Battito Irregolare (IHB) 5. Classificatore della pressione arteriosa 6. Memoria dati • Visualizzare i valori memorizzati • Memoria piena • Cancellare tutti i valori 7. Indicatore e sostituzione batteria • Batterie quasi esaurite • Batterie esaurite – sostituzione • Quali batterie e quale procedura? • Uso di batterie ricaricabili 8. Utilizzo del trasformatore 9. Messaggi di errore 10. Sicurezza, cura, test di precisione e smaltimento • Sicurezza e protezione • Cura del dispositivo • Pulizia del bracciale • Test di precisione • Smaltimento 11. Garanzia 12. Specifiche tecniche Tagliando di garanzia (retro di copertina) BP A3 Plus 1. Informazioni importanti sulla pressione arteriosa e l'automisurazione  La pressione arteriosa è la pressione del sangue che fluisce nelle arterie generata dal pompaggio del cuore. Si misurano sempre due valori, quello sistolico (massima) e quello diastolico (minima).  Il dispositivo indica anche la frequenza cardiaca (il numero di battiti del cuore in un minuto).  Valori pressori costantemente alti possono danneggiare la salute e dovono essere curati dal proprio medico!  E' utile mostrare sempre al medico i valori misurati e informarlo di eventuali anomalie osservate o riscontrate. Non fare mai affidamento su un'unica misurazione della pressione.  Esistono molte cause di valori della pressione eccessivamente alti. Il medico può fornire ulteriori informazioni o prescrivere un trattamento se necessario. Oltre al trattamento farmacologico, la perdita di peso e l'esercizio fisico possono contribuire all'abbassamento della pressione.  Per nessun motivo, modificare il dosaggio dei farmaci prescritti dal medico o iniziare un trattamento senza averlo consultato.  In base all'attività e alle condizioni fisiche, la pressione arteriosa è soggetta a fluttuazioni nel corso della giornata. Pertanto, la misurazione deve avvenire in condizioni di calma e di rilassamento! Effettuare ogni volta almeno due misurazioni successive (la mattina e la sera) e fare la media delle misurazioni.  E' assolutamente normale che due misurazioni a distanza ravvicinata possano dare risultati molto diversi. Per questo motivo raccomandiamo di misurare la pressione con la tecnologia MAM.  Differenze fra le misurazioni eseguite dal medico o in farmacia e quelle effettuate a casa sono normali, in quanto le situazioni sono completamente diverse.  Misurazioni ripetute forniscono informazioni molto più affidabili sulla pressione arteriosa che un'unica misurazione. Per questo motivo raccomandiamo di misurare la pressione con la tecnologia MAM.  Fra una misurazione e l'altra far passare un intervallo di almeno 15 secondi.  Se si soffre di aritmia cardiaca, consultare il proprio medico prima di utilizzare il dispositivo e leggere anche il capitolo «Comparsa del simbolo di Battito Irregolare (IHB)» di questo manuale d’uso. 25 IT  L'indicatore di pulsazioni non è adatto per registrare la frequenza dei pacemaker!  In gravidanza, la pressione deve essere monitorata regolarmente in quanto possono manifestarsi cambiamenti drastici. Questo dispositivo è studiato specificatamente per l'uso in gravidanza e pre-eclampsia. Se vengono rilevati valori della pressione insolitamente elevati in gravidanza, si consiglia di ripetere nuovamente la misurazione dopo circa un'ora. Se i valori sono ancora troppo elevati si consiglia di consultare il proprio medico o il ginecologo. 2. E' ora possibile impostare il mese usando il tasto M. Per confermare premere il tasto dell'ora e poi impostare il giorno. 3. Seguire le istruzioni precedenti per impostare giorno, ora e minuti. 4. Dopo aver impostato i minuti e premuto il tasto dell'ora, la data e l'ora saranno impostate e l'ora verrà visualizzata. 5. Per modificare la data e l'ora, premere e tenere premuto il tasto dell'ora per ca. 3 secondi fino a che il numero dell'anno inizierà a lampeggiare. Ora è possibile immettere i nuovi valori come precedentemente descritto. Come valutare la propria pressione arteriosa Tabella per la classificazione dei valori della pressione arteriosa negli adulti in conformità con le linee guida internazionali (ESH, ESC, JSH). Dati in mmHg. Selezione del bracciale adatto Microlife offre diverse misure di bracciale. Selezionare la misura del bracciale che corrisponde alla circonferenza del braccio (misurata mediante applicazione al centro del braccio). Misura del bracciale per circonferenza del braccio S 17 - 22 cm M 22 - 32 cm M-L 22 - 42 cm L 32 - 42 cm L - XL 32 - 52 cm E' possibile utilizzare anche i bracciali preformati «Easy», facili da indossare e confortevoli. Usare esclusivamente bracciali Microlife!  Contattare il rivenditore Microlife di zona se le misure dei bracciali in dotazione 6 non sono adatte per acquistarne uno nuovo.  Collegare il bracciale al dispositivo inserendo il raccordo del bracciale 7 nella presa del bracciale 3 il più profondamente possibile.  Ambito 1. pressione arteriosa normale 2. pressione arteriosa ottimale 3. pressione arteriosa alta 4. pressione arteriosa troppo alta 5. pressione arteriosa pericolosamente alta Sistolica < 120 Diastolica < 74 Raccomandazioni autocontrollo 120 - 129 74 - 79 autocontrollo 130 - 134 80 - 84 autocontrollo 135 - 159 85 - 99 ≥ 160 ≥ 100 consultare il medico consultare il medico con urgenza! Il valore più elevato è quello che determina la valutazione. Esempio: un valore di 140/80 mmHg o un valore di pressione arteriosa di 130/ 90 mmHg indica «una pressione arteriosa troppo alta». 2. Utilizzo del dispositivo per la prima volta Inserimento delle batterie Dopo aver estratto il dispositivo dall’imballaggio inserire le batterie. Il vano batterie 4 si trova sul fondo del dispositivo. Inserire le batterie (4 x 1,5 V, tipo AA) osservando la polarità indicata. Impostazione data e ora 1. Dopo aver inserito le nuove batterie il numero dell'anno lampeggerà sul display. E' possibile impostare l'anno premendo il tasto M AT. Per confermare e impostare il mese, premere il tasto dell'ora AK. 26   Selezione dell'utente Questo dispositivo permette di memorizzare separatamente le misurazioni di 2 utenti.  Prima di ogni misurazione, posizionare il selettore utente 9 in base all'utilizzatore: utente 1 o utente 2.  Utente 1: far scorrere in avanti il selettore 9 verso l'icona dell'utente 1.  Utente 2: far scorrere indietro il selettore 9 verso l'icona dell'utente 2. La prima persona che effettua una misurazione dovrebbe selezionare l'utente 1.  Selezionare la modalità standard o MAM Questo dispositivo consente di selezionare la modalità standard (misurazione standard singola) o la modalità MAM (3 misurazioni automatiche). Per selezionare la modalità standard, far scorrere il tasto MAM 8 in avanti nella posizione «1» e per selezionare la modalità MAM far scorrere il tasto indietro in posizione «3». Modalità MAM (altamente raccomandata)  In modalità MAM, vengono eseguite automaticamente 3 misurazioni consecutive e i risultati verranno analizzati e visualizzati automaticamente. La pressione arteriosa fluttua costantemente, pertanto un risultato determinato in questo modo è più affidabile che quello di una singola misurazione.  Quando viene selezionata la modalità delle 3 misurazioni, il simbolo MAM BL appare sul display.  La sezione in basso a destra del display visualizza 1, 2 o 3 per indicare quale delle 3 misurazioni è in corso.  C'è una pausa di 15 secondi tra una misurazione e l'altra. Un conto alla rovescia indica il tempo rimanente.  I risultati individuali non vengono visualizzati. La pressione arteriosa sarà visualizzata solo dopo l'esecuzione di tutte e tre le misurazioni.  Fra una misurazione e l'altra non togliere il bracciale.  Se una delle misurazioni individuali è dubbia, ne verrà eseguita automaticamente una quarta. 3. Misurazione della pressione arteriosa Punti da osservare per eseguire una misurazione affidabile 1. Immediatamente prima della misurazione evitare di fare attività fisica, mangiare o fumare. 2. Stare seduti su una sedia con schienale e rilassarsi per 5 minuti prima della misurazione. Mantenere i piedi ben appoggiati a terra e non accavallare le gambe. 3. Effettuare la misurazione sempre sullo stesso braccio (in genere il sinistro). E' consigliabile che il medico effettui alla prima visita una doppia misurazione a entrambe le braccia per determinare dove misurare la pressione successivamente. Effettuare le misurazioni nel braccio con la pressione più alta. 4. Togliere gli abiti che stringono il braccio. Per evitare costrizioni, non arrotolare le maniche della camicia - non interferiscono con il bracciale se questo viene indossato sopra. 5. Assicurarsi sempre che venga utilizzato il bracciale della dimensione corretta (come riportato sul bracciale). BP A3 Plus  Stringere il bracciale, ma non troppo.  Assicurarsi che il bracciale sia posizionato 1-2 cm sopra il gomito.  L’indicatore dell'arteria riportato sul bracciale (barra colorata di ca. 3 cm di lunghezza) deve essere posizionato sopra l'arteria che corre lungo il lato interno del braccio.  Sostenere il braccio in modo che sia rilassato.  Verificare che il bracciale si trovi più o meno all' altezza del cuore. 6. Premere il tasto ON/OFF 1 per iniziare la misurazione. 7. Il bracciale si gonfierà automaticamente. Stare in posizione rilassata, non muoversi e rilassare i muscoli del braccio fino a che verranno visualizzati i risultati della misurazione. Respirare normalmente e non parlare. 8. Quando è stata raggiunta la corretta pressione di gonfiaggio, l'apparecchio si ferma e la pressione scende gradualmente. Se la pressione necessaria non è stata raggiunta, il dispositivo gonfierà automaticamente il bracciale di quanto necessario. 9. Durante la misurazione, l'indicatore delle pulsazioni BT lampeggia sul display. 10.Al termine della misurazione vengono visualizzati i valori della pressione sistolica AO, della pressione diastolica AP e della frequenza cardiaca AQ. Consultare le spiegazioni delle altre visualizzazioni in questo manuale. 11.Al termine della misurazione togliere il bracciale. 12.Spegnere il dispositivo. Il display si spegne automaticamente dopo ca. 1 min. Come non memorizzare una misurazione Quando la misurazione è visualizzata sul display tenere premuto il tasto ON/OFF 1 fino a quando lampeggerà il simbolo «M» BO. Confermare la cancellazione della misurazione premendo il tasto M AT. E' possibile interrompere la misurazione in qualsiasi momento premendo il tasto ON/OFF (es. in caso di fastidio o di sensazione di pressione fastidiosa). In presenza di pressione sistolica alta (ad es. sopra i 135 mmHg) è opportuno impostare la pressione individualmente. Premere il tasto ON/OFF dopo che il misuratore ha superato il valore sistolico stimato di 30 mmHg (visualizzato sul display). Mantenere premuto il tasto fino a che la pressione supererà di 40 mmHg il valore sistolico stimato, quindi rilasciarlo.   27 IT 4. Comparsa del simbolo di Battito Irregolare (IHB) Questo simbolo BM indica che è stato rilevato un battito irregolare. In questo caso, i valori della pressione misurata potrebbero discostarsi da quelli abituali. Si consiglia di ripetere la misurazione. Informazione per il medico nel caso in cui il simbolo IHB compaia ripetutamente: Questo dispositivo è un misuratore di pressione oscillometrico che durante la misurazione della pressione rileva anche il battito cardiaco e segnala quando la frequenza cardiaca è irregolare. 5. Classificatore della pressione arteriosa Le barre a sinistra nel display AR indicano l'intervallo entro il quale si trova il valore di pressione arteriosa misurato. A seconda dell'altezza e del colore raggiunto dal classificatore la valutazione sarà ottimale (verde), elevata (giallo), alta (arancione) e pericolosamente alta (rosso). La classificazione corrisponde ai 4 livelli previsti dalle linee guida internazionali (ESH, ESC, JSH) come descritto nella «Sezione 1.». 6. Memoria dati Questo dispositivo memorizza 99 misurazioni per ognuno dei 2 utenti. Visualizzare i valori memorizzati Selezionare l'utente 1 o 2 con il selettore utente 9. Premere brevemente il tasto M AT, quando il dispositivo è spento. Sul display apparirà prima la «M» BO con la «A», che indica la media di tutti i valori memorizzati. Premendo ancora il tasto M, viene visualizzato il valore precedente. La pressione ripetuta del tasto M consente di passare da un valore memorizzato ad un altro. Memoria piena Fare attenzione a non superare la capacità massima di memorizzazione che è di 99 misurazioni per utente. Quando le 99 memorie sono piene, la misurazione più vecchia verrà sovrascritta dalla 100esima misurazione. Le misurazioni memorizzate dovrebbero essere valutate dal proprio medico prima di raggiungere la capacità di memorizzazione massima – contrariamente i dati andranno persi. Cancellare tutti i valori Assicurarsi che sia selezionato l'utente corretto.  28 1. Selezionare l'utente 1 o 2 con il selettore utente 9, quando il dispositivo è spento. 2. Tenere premuto il tasto M AT fino a quando il simbolo «CL» verrà visualizzato e rilasciare il tasto. 3. Quando il simbolo «CL» lampeggerà premere nuovamente il tasto M per cancellare definitivamente tutte le misurazioni dell'utente selezionato. Annullamento della cancellazione: premere il tasto ON/ OFF 1 quando il simbolo «CL» lampeggia. Non è possibile cancellare singole misurazioni.   7. Indicatore e sostituzione batteria Batterie quasi esaurite Quando le batterie sono esaurite di circa ¾, lampeggerà il simbolo della batteria AM appena si accenderà il dispositivo (visualizzazione batteria parzialmente carica). Anche se il dispositivo effettuerà le misurazioni in modo affidabile è necessario sostituire le batterie. Batterie esaurite – sostituzione Quando le batterie sono esaurite, lampeggerà il simbolo AM non appena si accenderà il dispositivo (visualizzazione batteria esaurita). Non devono essere eseguite ulteriori misurazioni e le batterie devono essere sostituite. 1. Aprire il vano batterie 4 sul fondo del dispositivo. 2. Sostituire le batterie verificando che la polarità sia quella indicata dai simboli nel vano batterie. 3. Impostare data e ora seguendo la procedura descritta nel «capitolo 2.». Le misurazioni memorizzate verranno mantenute in memoria mentre data e ora verranno cancellate – i segmenti del display relativi a data e ora lampeggeranno. Quali batterie e quale procedura? Usare 4 batterie alcaline AA da 1,5 V nuove, a lunga durata. Non usare le batterie dopo la data di scadenza indicata. Rimuovere le batterie se il dispositivo non viene usato per un periodo prolungato. Uso di batterie ricaricabili E' possibile usare questo dispositivo con batterie ricaricabili. Usare esclusivamente batterie ricaricabili di tipo «NiMH». Quando compare il simbolo di batteria scarica, è necessario rimuovere le batterie e ricaricarle. Le batterie non devono restare nel dispositivo, potrebbero danneggiarsi (scaricamento totale anche quando il dispositivo è spento).         Rimuovere sempre le batterie ricaricabili se si prevede di non usare il dispositivo per una settimana o un periodo più lungo. Le batterie non possono essere caricate nel misuratore di pressione! Ricaricare le batterie con un carica batterie esterno e osservare le istruzioni del produttore su carica, cura e durata. 8. Utilizzo del trasformatore E' possibile usare il dispositivo con il trasformatore Microlife (DC 6V, 600 mA). Usare esclusivamente il trasformatore Microlife disponibile come accessorio originale, adatto alla tensione di utilizzo. Controllare che né il trasformatore, né il cavo siano danneggiati. 1. Inserire il cavo del trasformatore nella presa prevista 5 del misuratore di pressione. 2. Inserire la spina del trasformatore nella presa a muro. Quando è collegato il trasformatore, le batterie non vengono consumate.   9. Messaggi di errore In caso di errore durante la misurazione, questa viene interrotta e viene visualizzato un messaggio di errore, es. «ERR 3». Errore Descrizione Probabile causa e rimedio «ERR 1» Segnale Le pulsazioni rilevate dal bracciale sono troppo troppo deboli. Riposizionare il bracciale debole e ripetere la misurazione.* «ERR 2» Segnale di Durante la misurazione sono stati rilevati BN errore segnali di errore dal bracciale, causati probabilmente da movimento o tensione muscolare. Ripetere la misurazione, tenendo fermo il braccio. «ERR 3» Assenza di Non è possibile generare una pressione BK pressione adeguata nel bracciale. Può esserci una nel bracperdita. Controllare che il bracciale sia ciale correttamente collegato e non sia troppo largo. Sostituire le batterie se necessario. Ripetere la misurazione. «ERR 5» Risultati I segnali della misurazione non sono anomali accurati e la misurazione non può essere visualizzata. Leggere le istruzioni per l'esecuzione di una misurazione affidabile e ripetere la misurazione.* BP A3 Plus Errore Descrizione Probabile causa e rimedio «ERR 6» Modalità Troppi errori durante la misurazione in modalità MAM, che rendono impossibile MAM ottenere un risultato finale. Leggere le istruzioni per l'esecuzione di una misurazione affidabile e ripetere la misurazione.* «HI» Frequenza La pressione nel bracciale è troppo alta o pressione (superiore a 299 mmHg) o la frequenza del braccardiaca è troppo alta (superiore a ciale troppo 200 battiti al minuto). Stare rilassati per alte 5 minuti e ripetere la misurazione.* «LO» Frequenza La frequenza cardiaca è troppo bassa troppo (inferiore a 40 battiti al minuto). Ripetere bassa la misurazione.* * Consultare immediatamente il proprio medico se questo o altri problemi si verificano ripetutamente. Se si ritiene che i risultati siano diversi da quelli abituali, leggere attentamente le informazioni del «capitolo 1.».  10. Sicurezza, cura, test di precisione e smaltimento  Sicurezza e protezione  Seguire le istruzioni d'uso. Questo manuale contiene informazioni importanti sul funzionamento e la sicurezza di questo dispositivo. Si prega di leggere attentamente le istruzioni d'uso prima di utilizzare il dispositivo e di conservarle per ogni futura consultazione.  Questo dispositivo deve essere usato esclusivamente come descritto in questo manuale. Il produttore non può essere ritenuto responsabile di danni causati da un utilizzo improprio.  Questo dispositivo è costruito con componenti delicati e deve essere trattato con attenzione. Osservare le condizioni di stoccaggio e funzionamento descritte nel capitolo «Specifiche tecniche».  Proteggere il dispositivo da: - acqua e umidità - temperature estreme - urti e cadute - contaminazione e polvere - luce solare diretta - caldo e freddo  I bracciali sono delicati e devono essere trattati con cura.  Non sostituire o utilizzare altri bracciali o raccordi di altri produttori per questo dispositivo. 29 IT  Gonfiare il bracciale solo dopo averlo indossato.  Non usare il dispositivo vicino a forti campi elettromagnetici come telefoni cellulari o installazioni radio. Mantenere una distanza minima di 3,3 m da altri apparecchi quando si utilizza questo dispositivo.  Non usare il dispositivo se si ritiene che sia danneggiato o se si nota qualcosa di strano.  Non aprire mai il dispositivo.  Rimuovere le batterie se il dispositivo non viene usato per un periodo prolungato.  Leggere le ulteriori informazioni sulla sicurezza nelle varie sezioni di questo manuale.  La misurazione ottenuta con questo dispositivo non rappresenta una diagnosi. Non sostituisce la consultazione del proprio medico curante, soprattutto se il risultato non è corrispondente ai propri sintomi. Non fare affidamento solo sulla misurazione, considerare sempre altri sintomi che potrebbero manifestarsi e lo stato generale del paziente. Se necessario si consiglia di chiamare un medico o un'ambulanza. Assicurarsi che i bambini non utilizzino il dispositivo senza la supervisione di un adulto. Alcune parti sono piccole e potrebbero essere ingerite. Prestare attenzione al rischio di strangolamento in presenza di cavi o tubi. Cura del dispositivo Pulire il dispositivo esclusivamente con un panno morbido e asciutto. Pulizia del bracciale Rimuovere con cautela eventuali tracce di sporco sul bracciale con un panno inumidito con acqua e sapone. AVVERTENZA: Non lavare il bracciale in lavatrice o lavastoviglie! Test di precisione Consigliamo di verificare la precisione di questo dispositivo ogni 2 anni o dopo un impatto meccanico (es. caduta). Contattare il locale servizio consumatori Microlife per eseguire il test (vedi introduzione).  Smaltimento Le batterie e gli strumenti elettronici devono essere smaltiti in conformità alle disposizioni locali e non come i rifiuti domestici. 30 11. Garanzia Questo dispositivo è coperto da una garanzia di 5 anni dalla data di acquisto. Durante questo periodo di garanzia, a nostra discrezione, Microlife riparerà o sostituirà gratuitamente il prodotto difettoso. L'apertura o la manomissione del dispositivo invalidano la garanzia. Sono esclusi dalla garanzia:  Costi e rischi di trasporto.  Danni causati da un uso scorretto o dal mancato rispetto delle istruzioni d'uso.  Danni causati da perdite delle batterie.  Danni causati da caduta o uso improprio.  Materiale di imballaggio/stoccaggio e istruzioni d'uso.  Controlli regolari e manutenzione (calibrazione).  Accessori e parti soggette a usura: Batterie, alimentatore (opzionale). Il bracciale è coperto da una garanzia di funzionalità (tenuta della camera d'aria) per 2 anni. Qualora fosse necessario il servizio di assistenza in garanzia, contattare il rivenditore da cui è stato acquistato il prodotto o il servizio locale Microlife sul sito www.microlife.com/support Il risarcimento è limitato al valore del prodotto. La garanzia verrà concessa se il prodotto completo viene restituito con la fattura o scontrino originale. La riparazione o sostituzione in garanzia non prolunga o rinnova il periodo di garanzia. Le rivendicazioni legali e i diritti dei consumatori non sono limitati da questa garanzia. 12. Specifiche tecniche Condizioni di esercizio: Condizioni di stoccaggio: Peso: Dimensioni: Procedura di misurazione: 10 - 40 °C / 50 - 104 °F 15 - 95 % umidità relativa massima -20 - +55 °C / -4 - +131 °F 15 - 95 % umidità relativa massima 368 g (comprese batterie) 143 x 85 x 58 mm oscillometrica, corrispondente al metodo di Korotkoff: fase I sistolica, fase V diastolica Range di misurazione: 20 - 280 mmHg – pressione arteriosa 40 - 200 battiti al minuto – pulsazioni Range pressione di gonfiaggio del bracciale: 0 - 299 mmHg Risoluzione: 1 mmHg Precisione pressione statica: pressione entro ± 3 mmHg Precisione pulsazioni: ± 5 % del valore letto Alimentazione: 4 x batterie alcaline da 1,5 Volt; tipo AA trasformatore DC 6V, 600 mA (optional) Durata batterie: approssim. 920 misurazioni (usando batterie nuove) Classe IP: IP20 Riferimento agli EN 1060-1 /-3 /-4; IEC 60601-1; standard: IEC 60601-1-2 (EMC); IEC 60601-1-11 Aspettativa di vita del Dispositivo: 5 anni o 10000 misurazioni prodotto in uso: Accessori: 2 anni Questo dispositivo è conforme alla direttiva sui prodotti medicali 93/42/EEC. Con riserva di apportare modifiche tecniche. BP A3 Plus 31 IT Microlife BP A3 Plus 1 2 3 4 5 6 7 8 9 AT AK Ein-/Aus-Taste Display Manschetten-Anschluss Batteriefach Netzadapter-Anschluss Manschette Manschettenstecker MAM-Schalter Benutzerwechsel-Schalter M-Taste (Speicher) Uhrzeit-Taste Display AL Benutzeranzeige AM Batterieanzeige AN Datum/Uhrzeit AO Systolischer Wert AP Diastolischer Wert AQ Pulsschlag AR Ampel-Indikator AS MAM-Wartezeit BT Puls-Indikator BK Manschettenprüf-Indikator BL MAM-Modus BM Symbol für unregelmässigen Herzschlag (IHB) BN Armbewegungs-Indikator BO Speicherwert Vor Verwendung Bedienungsanleitung genau studieren. Anwendungsteil des Typs BF Vor Nässe schützen 32 DE Verwendungszweck: Dieses oszillometrische Blutdruckmessgerät dient zur Messung des nicht-invasiven Blutdrucks bei Personen im Alter von 12 Jahren oder älter. Es ist klinisch validiert bei Patienten mit Hypertonie, Hypotonie, Diabetes, Schwangerschaft, Präeklampsie, Atherosklerose, Nierenerkrankungen im Endstadium, Fettleibigkeit und ältere Menschen. Sehr geehrter Kunde, Dieses Gerät wurde in Zusammenarbeit mit Ärzten entwickelt und die hohe Messgenauigkeit ist klinisch getestet.* Wenden Sie sich bei Fragen, Problemen oder Ersatzteilbedarf jederzeit gerne an den lokalen Microlife-Service. Ihr Händler oder Apotheker kann Ihnen die Adresse der Microlife-Landesvertretung mitteilen. Eine Vielzahl nützlicher Informationen zu unseren Produkten finden Sie auch im Internet unter www.microlife.com. Wir wünschen Ihnen alles Gute für Ihre Gesundheit – Microlife AG! * Dieses Gerät verwendet die gleiche Messtechnologie wie das nach dem Protokoll der Britischen und Irischen Hochdruck Gesellschaft (BIHS) in London mit bester Auszeichnung getestete Modell «BP 3BTO-A». Inhaltsverzeichnis 1. Wichtige Informationen zum Blutdruck und zur Selbstmessung • Wie beurteile ich meinen Blutdruck? 2. Erste Inbetriebnahme des Geräts • Einlegen der Batterien • Einstellen von Datum und Uhrzeit • Auswahl der richtigen Manschette • Auswahl des Benutzers • Auswahl Normal- oder MAM-Modus • MAM-Modus (sehr zu empfehlen) 3. Durchführung einer Blutdruckmessung • Ein Messergebnis nicht speichern 4. Anzeige des Symbols für unregelmässigen Herzschlag (IHB) 5. Ampelanzeige am Display 6. Messwertspeicher • Anzeigen der gespeicherten Werte • Speicher voll • Löschen aller Werte 7. Batterieanzeige und Batteriewechsel • Batterien bald leer • Batterien leer – Batterieaustausch • Welche Batterien und was beachten? • Verwendung wiederaufladbarer Batterien (Akkumulatoren) 8. Verwendung eines Netzadapters 9. Fehlermeldungen und Probleme 10. Sicherheit, Pflege, Genauigkeits-Überprüfung und Entsorgung • Sicherheit und Schutz • Pflege des Gerätes • Reinigung der Manschette • Genauigkeits-Überprüfung • Entsorgung 11. Garantie 12. Technische Daten Garantiekarte (siehe Rückseite) BP A3 Plus 1. Wichtige Informationen zum Blutdruck und zur Selbstmessung  Blutdruck ist der Druck des in den Blutgefässen fliessenden Blutes, verursacht durch das Pumpen des Herzens. Es werden immer zwei Werte gemessen, der systolische (obere) Wert und der diastolische (untere) Wert.  Das Gerät gibt Ihnen ausserdem den Pulswert an (wie oft das Herz in der Minute schlägt).  Auf Dauer erhöhte Blutdruckwerte können zu Gesundheitsschäden führen und müssen deshalb von Ihrem Arzt behandelt werden!  Besprechen Sie Ihre Werte, besondere Auffälligkeiten oder Unklarheiten immer mit Ihrem Arzt. Verlassen Sie sich niemals nur auf die Blutdruckmesswerte allein.  Es gibt mehrere Ursachen für zu hohe Blutdruckwerte. Ihr Arzt wird Sie genauer darüber informieren und bei Bedarf entsprechend behandeln. Neben Medikamenten können z.B. Gewichtsabnahme oder Sport Ihren Blutdruck senken.  Verändern Sie unter keinen Umständen die Dosierung von Medikamenten oder beginnen Sie keine Behandlung ohne Rücksprache mit Ihrem Arzt.  Je nach Anstrengung und Befinden während des Tagesverlaufs unterliegt der Blutdruck starken Schwankungen. Messen Sie deshalb täglich unter ruhigen und vergleichbaren Bedingungen und wenn Sie sich entspannt fühlen! Nehmen Sie jedes Mal mindestens zwei Messungen vor (am Morgen und am Abend) und berechnen Sie den Durchschnittswert.  Es ist normal, dass bei kurz hintereinander durchgeführten Messungen deutliche Unterschiede auftreten können. Wir empfehlen deshalb, die MAM-Technologie zu verwenden.  Abweichungen zwischen der Messung beim Arzt oder in der Apotheke und zu Hause sind normal, da Sie sich in ganz unterschiedlichen Situationen befinden.  Mehrere Messungen ergeben viel zuverlässigere Informationen über Ihren Blutdruck als nur eine Einzelmessung. Wir empfehlen deshalb, die MAM-Technologie zu verwenden.  Machen Sie zwischen zwei Messungen eine kurze Pause von mindestens 15 Sekunden.  Wenn Sie an einer Herzrhythmusstörung leiden, wenden Sie sich an Ihren Arzt, bevor Sie das Gerät verwenden. Siehe auch Kapitel «Anzeige des Symbols für unregelmässigen Herzschlag (IHB)» in dieser Bedienungsanleitung. 33 DE  Die Pulsanzeige ist nicht geeignet zur Kontrolle der Frequenz von Herzschrittmachern!  Während der Schwangerschaft sollten Sie Ihren Blutdruck regelmässig kontrollieren, da er deutlich variieren kann! Dieses Blutdruckmessgerät ist speziell für den Gebrauch während der Schwangerschaft und bei Präeklampsie getestet. Wenn Sie ungewöhnlich hohe Werte während der Schwangerschaft messen, sollten Sie nach einer kurzen Weile (z.B. 1 Stunde) noch einmal messen. Wenn der Wert immer noch zu hoch ist, konsultieren Sie Ihren Arzt oder Gynäkologen.  Wie beurteile ich meinen Blutdruck? Tabelle zur Klassifizierung von zuhause gemessenen Blutdruckwerten in Übereinstimmung mit den internationalen Richtlinien (ESH, ESC, JSH). Werte in mmHg. Bereich 1. normaler Blutdruck 2. optimaler Blutdruck 3. erhöhter Blutdruck 4. zu hoher Blutdruck 5. schwerer Bluthochdruck Systolisch < 120 120 - 129 Diastolisch < 74 74 - 79 130 - 134 80 - 84 135 - 159 85 - 99 ≥ 160 ≥ 100 Empfehlung Selbstkontrolle Selbstkontrolle Selbstkontrolle Ärztliche Kontrolle Dringende ärztliche Kontrolle! Für die Bewertung ist immer der höhere Wert entscheidend. Beispiel: bei den Messwerten von 140/80 mmHg oder 130/90 mmHg zeigt es «zu hoher Blutdruck» an. 2. Erste Inbetriebnahme des Geräts Einlegen der Batterien Nachdem Sie das Gerät ausgepackt haben, legen Sie die Batterien ein. Das Batteriefach 4 befindet sich auf der Geräteunterseite. Legen Sie die Batterien (4 x 1,5 V, Grösse AA) ein und achten Sie dabei auf die angezeigte Polarität. Einstellen von Datum und Uhrzeit 1. Nachdem neue Batterien eingelegt wurden, blinkt die Jahreszahl im Display. Sie können durch Drücken der M-Taste AT das 34 Jahr einstellen. Drücken Sie zur Bestätigung und um zur Monatseinstellung zu wechseln die Uhrzeit-Taste AK. 2. Der Monat kann nun durch die M-Taste eingestellt werden. Drücken Sie zur Bestätigung und um zur Tageseinstellung zu wechseln die Uhrzeit-Taste. 3. Gehen Sie weiter wie oben beschrieben vor, um Tag, Stunde und Minuten einzustellen. 4. Nachdem als letztes die Minuten eingestellt sind und die Uhrzeit-Taste AK gedrückt wurde, sind Datum und Uhrzeit eingestellt und die Zeit wird angezeigt. 5. Wenn Sie Datum und Uhrzeit einmal ändern möchten, halten Sie die Uhrzeit-Taste ca. 3 Sekunden lang gedrückt, bis die Jahreszahl zu blinken beginnt. Nun können Sie wie zuvor beschrieben die neuen Werte eingeben. Auswahl der richtigen Manschette Microlife bietet Ihnen verschiedene Manschettengrössen zur Auswahl. Massgebend ist der Umfang des Oberarms (eng anliegend, gemessen in der Mitte des Oberarms). Manschettengrösse für Oberarmumfang S 17 - 22 cm M 22 - 32 cm M-L 22 - 42 cm L 32 - 42 cm L - XL 32 - 52 cm Vorgeformte Manschetten «Easy» sind für bessere Passform und Komfort optional erhältlich. Verwenden Sie ausschliesslich Microlife Manschetten!  Sollte die beiliegende Manschette 6 nicht passen, wenden Sie sich bitte an den lokalen Microlife Service.  Verbinden Sie die Manschette mit dem Gerät, indem Sie den Stecker 7 fest bis zum Anschlag in die Manschettenbuchse 3 einstecken. Auswahl des Benutzers Dieses Gerät speichert die Daten für 2 individuelle Benutzer.  Vor jedem Messvorgang: schieben Sie den BenutzerwechselSchalter 9 auf den gewünschten Benutzer: Benutzer 1 oder 2.  Benutzer 1: Schieben Sie den Schalter 9 nach oben zum Symbol «Benutzer 1».  Benutzer 2: Schieben Sie den Schalter 9 nach unten zum Symbol «Benutzer 2».   Die zuerst messende Person sollte Benutzer 1 wählen.  Auswahl Normal- oder MAM-Modus Sie können bei diesem Gerät wählen, ob Sie die Messung im Normal-Modus (normale Einfach-Messung) oder im MAM-Modus (automatische Dreifach-Messung) durchführen möchten. Für den Normal-Modus schieben Sie den MAM-Schalter 8 an der Seite des Geräts auf Position «1» nach unten, für den MAM-Modus auf Position «3» nach oben. MAM-Modus (sehr zu empfehlen)  Im MAM-Modus werden automatisch 3 Messungen nacheinander durchgeführt und danach wird das Ergebnis automatisch analysiert und angezeigt. Da der Blutdruck ständig schwankt ist ein so ermitteltes Ergebnis zuverlässiger als eine Einzelmessung.  Wenn Sie die Dreifach-Messung auswählen, erscheint das MAM-Symbol BL im Display.  Rechts unten im Display wird durch 1, 2 oder 3 angezeigt, welche der 3 Messungen gerade durchgeführt wird.  Zwischen den einzelnen Messungen erfolgt eine Pause von je 15 Sekunden. Ein Countdown zeigt die verbleibende Zeit an.  Die Einzelergebnisse werden nicht angezeigt. Der Blutdruckwert wird angezeigt, nachdem alle 3 Messungen durchgeführt wurden.  Lassen Sie die Manschette zwischen den Messungen angelegt.  Falls eine Einzelmessung fehlerhaft war, wird automatisch eine vierte Messung durchgeführt. 3. Durchführung einer Blutdruckmessung Checkliste für die Durchführung einer zuverlässigen Messung 1. Vermeiden Sie kurz vor der Messung Anstrengung, Essen und Rauchen. 2. Setzen Sie sich auf einen Stuhl mit Rückenlehne und entspannen Sie sich für 5 Minuten. Halten Sie die Füsse flach auf dem Boden und kreuzen Sie Ihre Beine nicht. 3. Messen Sie immer am gleichen Arm (normalerweise am Linken). Es wird empfohlen, dass Ärzte beim ersten Besuch des Patienten an beiden Armen messen, um zu bestimmen, an welchem Arm in Zukunft gemessen werden soll. Wählen Sie den Arm mit dem höheren Blutdruck. 4. Legen Sie einengende Kleidungsstücke am Oberarm ab. Ein Hemd sollte zur Vermeidung von Einschnürungen nicht hochgekrempelt werden - glatt anliegend stört es unter der Manschette nicht. BP A3 Plus 5. Stellen Sie sicher, dass immer die korrekte Manschettengrösse gebraucht wird (Markierung auf der Manschette).  Legen Sie die Manschette eng aber nicht zu stramm an.  Stellen Sie sicher, dass die Manschette 1-2 cm über der Ellenbeuge positioniert ist.  Die Arterienmarkierung auf der Manschette (ca. 3 cm langer Balken) muss über der Arterie liegen, welche auf der Innenseite des Armes entlang läuft.  Stützen Sie den Arm zur Entspannung ab.  Achten Sie darauf, dass sich die Manschette auf Herzhöhe befindet. 6. Starten Sie die Messung durch Drücken der Ein/Aus-Taste 1. 7. Die Manschette wird nun automatisch aufgepumpt. Entspannen Sie sich, bewegen Sie sich nicht und spannen Sie die Armmuskeln nicht an bis das Ergebnis angezeigt wird. Atmen Sie ganz normal und sprechen Sie nicht. 8. Wenn der richtige Druck erreicht ist, stoppt das Aufpumpen und der Druck fällt allmählich ab. Sollte der Druck nicht ausreichend gewesen sein, pumpt das Gerät automatisch nach. 9. Während der Messung blinkt der Puls-Indikator BT im Display. 10.Das Ergebnis, bestehend aus systolischem AO und diastolischem AP Blutdruck sowie dem Pulsschlag AQ, wird angezeigt. Beachten Sie auch die Erklärungen zu weiteren DisplayAnzeigen in dieser Anleitung. 11.Entfernen Sie die Manschette nach der Messung vom Gerät. 12.Schalten Sie das Gerät aus. (Auto-Aus nach ca. 1 Min.). Ein Messergebnis nicht speichern Sobald das Resultat auf dem Display erscheint, drücken und halten Sie die Ein/Aus-Taste 1 bis «M» BO blinkt. Bestätigen Sie den Löschvorgang indem Sie die M-Taste AT drücken. Sie können die Messung jederzeit durch Drücken der Ein/ Aus-Taste abbrechen (z.B. Unwohlsein oder unangenehmer Druck). Bei bekanntem sehr hohem systolischem Blutdruck kann es von Vorteil sein, den Druck selbst vorzugeben. Drücken Sie dazu die Ein/Aus-Taste nachdem das Gerät mit dem Aufpumpen begonnen hat und ein Druckwert von ca. 30 mmHg im Display angezeigt wird. Halten Sie die Taste gedrückt bis der Druck ca. 40 mmHg über dem erwarteten systolischen Wert ist und lassen die Taste dann los.   35 DE 4. Anzeige des Symbols für unregelmässigen Herzschlag (IHB) Dieses Symbol BM zeigt an, dass ein unregelmäßiger Herzschlag festgestellt wurde. In diesem Fall kann der gemessene Blutdruck von Ihren tatsächlichen Blutdruckwerten abweichen. Es wird empfohlen, die Messung zu wiederholen. Hinweise für den Arzt bei wiederholtem Auftreten des IHBSymbols: Dieses Gerät ist ein oszillometrisches Blutdruckmessgerät, das auch den Puls während der Blutdruckmessung misst und anzeigt wenn der Herzschlag unregelmässig ist. 5. Ampelanzeige am Display Die Balken AR am linken Rand des Displays zeigen Ihnen den Bereich an, in dem Ihr Blutdruckwert liegt. Abhängig von der Höhe der Balken ist der gemessene Wert entweder optimal (grün), erhöht (gelb), zu hoch (orange) oder gefährlich hoch (rot). Die Klassifizierung orientiert sich an den 4 Bereichen in der Tabelle der internationalen Richtlinien (ESH, ESC, JSH), wie in «Kapitel 1.» beschrieben. 6. Messwertspeicher Dieses Gerät speichert automatisch bis zu 99 Messwerte pro Benutzer. Anzeigen der gespeicherten Werte Wählen Sie Benutzer 1 oder 2 mit dem Benutzerwechsel-Schalter 9 aus. Drücken Sie kurz die M-Taste AT, während das Gerät ausgeschaltet ist. Das Display zeigt zuerst «M» BO und «A» an, was für den Durchschnittwert aller gespeicherten Werte steht. Nochmaliges Drücken der M-Taste zeigt den vorherigen Wert an. Durch wiederholtes Drücken der M-Taste können Sie von einem zum anderen Speicherwert wechseln. Speicher voll Achten Sie darauf, dass die maximale Speicherkapazität von 99 Werten pro Benutzer nicht überschritten wird. Wenn der Speicher voll ist, wird der älteste Wert automatisch mit dem 100. Wert überschrieben. Die Werte sollten von einem Arzt kontrolliert werden, bevor die volle Speicherkapazität erreicht ist – ansonsten gehen die Daten verloren.  36 Löschen aller Werte Stellen Sie sicher, dass Sie den richtigen Benutzer ausgewählt haben. 1. Wählen Sie Benutzer 1 oder 2 mit dem BenutzerwechselSchalter 9 aus, während das Gerät ausgeschaltet ist. 2. Halten Sie die M-Taste AT gedrückt bis «CL» erscheint und lassen Sie dann los. 3. Drücken Sie die M-Taste während «CL» blinkt, um alle Werte des ausgewählten Benutzers endgültig zu löschen. Abbruch des Löschvorgangs: Drücken Sie die Ein/AusTaste 1 während «CL» blinkt. Einzelne Werte können nicht gelöscht werden.   7. Batterieanzeige und Batteriewechsel Batterien bald leer Wenn die Batterien zu etwa ¾ aufgebraucht sind, blinkt gleich nach dem Einschalten das Batteriesymbol AM (teilweise gefüllte Batterie). Sie können weiterhin zuverlässig mit dem Gerät messen, sollten aber Ersatzbatterien besorgen. Batterien leer – Batterieaustausch Wenn die Batterien aufgebraucht sind, blinkt gleich nach dem Einschalten das leere Batteriesymbol AM. Sie können keine Messung mehr durchführen und müssen die Batterien austauschen. 1. Öffnen Sie das Batteriefach 4 an der Geräteunterseite. 2. Tauschen Sie die Batterien aus – achten Sie auf die richtige Polung wie auf den Symbolen im Fach dargestellt. 3. Stellen Sie das Datum und Uhrzeit wie im «Kapitel 2.» beschrieben ein. Alle Werte bleiben im Speicher, jedoch Datum und Uhrzeit müssen neu eingestellt werden – deshalb blinkt nach dem Batteriewechsel automatisch die Jahreszahl.  Welche Batterien und was beachten? Verwenden Sie 4 neue, langlebige 1,5 V Alkaline-Batterien, Grösse AA. Verwenden Sie Batterien nicht über das angegebene Haltbarkeitsdatum hinaus. Entfernen Sie die Batterien, wenn das Gerät für längere Zeit nicht benutzt wird.    Verwendung wiederaufladbarer Batterien (Akkumulatoren) Sie können dieses Gerät auch mit wiederaufladbaren Batterien betreiben.     Verwenden Sie nur wiederaufladbare «NiMH»-Batterien. Wenn das Batteriesymbol (Batterie leer) angezeigt wird, müssen die Batterien herausgenommen und aufgeladen werden. Sie dürfen nicht im Gerät verbleiben, da sie zerstört werden könnten (Tiefenentladung durch geringen Verbrauch des Gerätes auch im ausgeschalteten Zustand). Nehmen Sie wiederaufladbare Batterien unbedingt aus dem Gerät, wenn Sie es für eine Woche oder länger nicht benutzen. Die Batterien können NICHT im Blutdruckmessgerät aufgeladen werden. Laden Sie die Batterien in einem externen Ladegerät auf und beachten Sie die Hinweise zur Ladung, Pflege und Haltbarkeit. 8. Verwendung eines Netzadapters Sie können dieses Gerät mit dem Microlife Netzadapter (DC 6V, 600 mA) betreiben. Verwenden Sie nur den als Original-Zubehör erhältlichen Microlife Netzadapter entsprechend Ihrer Netzspannung. Stellen Sie sicher, dass Netzadapter und Kabel keine Beschädigungen aufweisen. 1. Stecken Sie das Adapterkabel in den Netzadapter-Anschluss 5 des Blutdruckmessgerätes. 2. Stecken Sie den Adapterstecker in die Steckdose. Wenn der Netzadapter angeschlossen ist, wird kein Batteriestrom verbraucht.   9. Fehlermeldungen und Probleme Wenn bei der Messung ein Fehler auftritt, wird die Messung abgebrochen und eine Fehlermeldung, z.B. «ERR 3», angezeigt. Fehler Bezeichnung Möglicher Grund und Abhilfe «ERR 1» Zu schwaDie Pulssignale an der Manschette sind ches Signal zu schwach. Legen Sie die Manschette erneut an und wiederholen die Messung.* «ERR 2» Störsignal Während der Messung wurden StörsigBN nale an der Manschette festgestellt, z.B. durch Bewegen oder Muskelanspannung. Halten Sie den Arm ruhig und wiederholen Sie die Messung. BP A3 Plus Fehler Bezeichnung Möglicher Grund und Abhilfe «ERR 3» Kein Druck in Der Manschettendruck kann nicht BK der ausreichend aufgebaut werden. EvenManschette tuell liegt eine Undichtigkeit vor. Prüfen Sie, ob die Manschette richtig verbunden ist und nicht zu locker anliegt. Eventuell Batterien austauschen. Wiederholen Sie danach die Messung. «ERR 5» Anormales Die Messsignale sind ungenau und es Ergebnis kann deshalb kein Ergebnis angezeigt werden. Beachten Sie die Checkliste zur Durchführung zuverlässiger Messungen und wiederholen danach die Messung.* «ERR 6» MAM-Modus Es gab zu viele Fehler während der Messung im MAM-Modus, so dass kein Endergebnis ermittelt werden kann. Beachten Sie die Checkliste zur Durchführung zuverlässiger Messungen und wiederholen danach die Messung.* «HI» Puls oder Der Druck in der Manschette ist zu hoch Manschet(über 299 mmHg) oder der Puls ist zu tendruck zu hoch (über 200 Schläge pro Minute). hoch Entspannen Sie sich 5 Minuten lang und wiederholen Sie die Messung.* «LO» Puls zu Der Puls ist zu niedrig (unter niedrig 40 Schläge pro Minute). Wiederholen Sie die Messung.* * Sprechen Sie umgehend mit Ihrem Arzt, wenn diese oder andere Probleme wiederholt auftreten sollten. Wenn Ihnen die Ergebnisse ungewöhnlich erscheinen, beachten Sie bitte sorgfältig die Hinweise in «Kapitel 1.».  10. Sicherheit, Pflege, Genauigkeits-Überprüfung und Entsorgung Sicherheit und Schutz   Befolgen Sie diese Gebrauchsanweisung. Dieses Dokument enthält wichtige Informationen zum Betrieb und zur Sicherheit dieses Geräts. Bitte lesen Sie dieses Dokument sorgfältig durch, bevor Sie das Gerät benutzen und bewahren Sie es für die zukünftige Nutzung auf. 37 DE  Dieses Gerät darf nur für den in dieser Anleitung beschriebenen Zweck verwendet werden. Der Hersteller ist nicht für Schäden haftbar, die aus unsachgemässer Handhabung resultieren.  Dieses Gerät besteht aus sensiblen Bauteilen und muss vorsichtig behandelt werden. Beachten Sie die Lager- und Betriebsanweisungen im Kapitel «Technische Daten».  Schützen Sie das Gerät vor: - Wasser und Feuchtigkeit - extremen Temperaturen - Stössen und Herunterfallen - Schmutz und Staub - starker Sonneneinstrahlung - Hitze und Kälte  Die Manschette ist empfindlich und muss schonend behandelt werden.  Verwenden Sie keine anderen Manschetten oder Manschettenstecker für die Messung mit diesem Gerät.  Pumpen Sie die Manschette erst auf, wenn sie angelegt ist.  Benutzen Sie das Gerät nicht in der Nähe starker elektromagnetischer Felder wie z.B. Mobiltelefone oder Funkanlagen. Halten Sie einen Mindestabstand von 3,3 m zu solchen Geräten, wenn Sie dieses Gerät benutzen.  Benutzen Sie das Gerät nicht, wenn Sie einen Schaden erkennen oder Ihnen etwas Ungewöhnliches auffällt.  Öffnen Sie niemals das Gerät.  Entfernen Sie die Batterien, wenn das Gerät für längere Zeit nicht benutzt wird.  Beachten Sie die weiteren Sicherheitshinweise in den einzelnen Kapiteln dieser Anleitung.  Das von diesem Gerät angezeigte Messergebnis ist keine Diagnose. Es ersetzt nicht die Notwendigkeit einer fachlichen Einschätzung durch einen Mediziner, vor allem dann nicht, wenn das Ergebnis nicht dem Befinden des Patienten entspricht. Verlassen Sie sich nicht ausschliesslich auf das Messergebnis. Alle potenziell auftretenden Symptome und die Schilderung des Patienten müssen in Betracht gezogen werden. Die Verständigung eines Arztes oder Krankenwagens wird bei Bedarf empfohlen. Sorgen Sie dafür, dass Kinder das Gerät nicht unbeaufsichtigt benutzen; einige Teile sind so klein, dass sie verschluckt werden könnten. Beachten Sie das Strangulierungsrisiko sollte dieses Gerät mit Kabeln oder Schläuchen ausgestattet sein. 38 Pflege des Gerätes Reinigen Sie das Gerät nur mit einem weichen, trockenen Lappen. Reinigung der Manschette Entfernen Sie Verunreinigungen vorsichtig mit einem feuchten Tuch und Seife. WARNUNG: Waschen Sie die Manschette niemals in einer Waschmaschine oder in einem Geschirrspüler!  Genauigkeits-Überprüfung Wir empfehlen alle 2 Jahre oder nach starker mechanischer Beanspruchung (z.B. fallen lassen) eine Genauigkeits-Überprüfung dieses Gerätes durchführen zu lassen. Bitte wenden Sie sich dazu an den lokalen Microlife-Service (siehe Vorwort). Entsorgung Batterien und elektronische Geräte dürfen nicht in den Hausmüll, sondern müssen entsprechend den örtlichen Vorschriften entsorgt werden. 11. Garantie Für dieses Gerät gewähren wir 5 Jahre Garantie ab Kaufdatum. Während der Garantiezeit repariert oder ersetzt Microlife, nach eigenem Ermessen, das defekte Produkt kostenlos. Wurde das Gerät durch den Benutzer geöffnet oder verändert, erlischt der Garantieanspruch. Folgende Punkte sind von der Garantie ausgenommen  Transportkosten und Transportrisiken  Schäden die durch falsche Anwendung oder Nichteinhaltung der Gebrauchsanweisung verursacht wurden  Schäden durch auslaufende Batterien  Schäden durch Unfall oder Missbrauch  Verpackungs- / Lagermaterial und Gebrauchsanweisung  Regelmässige Kontrollen und Wartung (Kalibrierung)  Zubehör und Verschleissteile: Batterien, Netzteil (optional). Für die Manschette gilt eine Funktionsgarantie (Blasendichtheit) von 2 Jahren. Sollte ein Garantiefall eintreten, wenden Sie sich bitte an den Händler, bei dem das Produkt gekauft wurde oder an Ihren lokalen Microlife-Service. Sie können Ihren lokalen Microlife-Service über unsere Website kontaktieren: www.microlife.com/support Die Entschädigung ist auf den Wert des Produkts begrenzt. Die Garantie wird gewährt, wenn das vollständige Produkt mit der Originalrechnung zurückgesandt wird. Eine Reparatur oder ein Austausch innerhalb der Garantiezeit verlängert oder erneuert die Garantiezeit nicht. Die gesetzlichen Ansprüche und Rechte der Verbraucher sind durch die Garantie nicht eingeschränkt. 12. Technische Daten Betriebsbedingungen: Aufbewahrungsbedingungen: Gewicht: Grösse: Messverfahren: Messbereich: Displaybereich Manschettendruck: Messauflösung: Statische Genauigkeit: Pulsgenauigkeit: Spannungsquelle: BatterieLebensdauer: IP Klasse: Verweis auf Normen: Durchschnittliche Lebensdauer: 10 - 40 °C / 50 - 104 °F 15 - 95 % relative maximale Luftfeuchtigkeit -20 - +55 °C / -4 - +131 °F 15 - 95 % relative maximale Luftfeuchtigkeit 368 g (mit Batterien) 143 x 85 x 58 mm oszillometrisch, validiert nach KorotkoffMethode: Phase I systolisch, Phase V diastolisch 20 - 280 mmHg – Blutdruck 40 - 200 Schläge pro Minute – Puls 0 - 299 mmHg 1 mmHg Druck innerhalb ± 3 mmHg ± 5 % des Messwertes 4 x 1,5 V Alkaline-Batterien, Grösse AA Netzadapter DC 6V, 600 mA (optional) ca. 920 Messungen (mit neuen Batterien) IP20 EN 1060-1 /-3 /-4; IEC 60601-1; IEC 60601-1-2 (EMC); IEC 60601-1-11 Gerät: 5 Jahre oder 10000 Messungen Zubehör: 2 Jahre Dieses Gerät entspricht den Anforderungen der Richtlinie für Medizinische Geräte 93/42/EWG. Technische Änderungen vorbehalten. BP A3 Plus 39 DE Microlife BP A3 Plus 1 2 3 4 5 6 7 8 9 AT AK AÇ/KAPA Düğmesi Ekran Kaf Soketi Pil Bölmesi Elektrik Adaptörü Soketi Kaf Kaf Bağlantısı MAM Anahtarı Kullanıcı Anahtarı M-Düğme (Bellek) Zaman Düğmesi Ekran AL Kullanıcı Göstergesi AM Pil Göstergesi AN Tarih/Saat AO Büyük Tansiyon Değeri AP Küçük Tansiyon Değeri AQ Nabız Sayısı AR Trafik Işığı Göstergesi AS MAM Zaman Aralığı BT Nabız Göstergesi BK Kaf Onay Göstergesi BL MAM Modu BM Düzensiz Kalp Atışı (IHB) Sembolü BN Kol Hareketi Göstergesi BO Kaydedilen Değer Aygıtı kullanmadan önce, talimatları dikkatle okuyun. BF tipi ekipman Kuru tutun 40 TR Kullanım amacı: Bu osilometrik tansiyon aletinin kullanım amacı, 12 yaşından büyük kişilerin girişimsel olmayan kan basıncının ölçülmesidir. Hipertansiyon, hipotansiyon, diyabet, gebe, preeklampsi, ateroskleroz, son dönem böbrek hastalığı, obezite olan hastalarda ve yaşlı insanlarda klinik olarak doğrulandı. Sayın Müşterimiz, Aygıt, hekimlerle işbirliği içerisinde geliştirilmiştir ve yapılan bilimsel testlerin sonucunda ölçüm doğruluğunun oldukça yüksek olduğu kanıtlanmıştır.* Sorularınız, sorunlarınız ve yedek parça siparişleriniz için, lütfen, yerel Microlife-Müşteri Servisi ile görüşün. Ülkenizdeki Microlife bayisinin adresini satıcınızdan ya da eczanenizden öğrenebilirsiniz. İkinci bir yol olarak, ürünlerimiz hakkında geniş bilgi edinebileceğiniz www.microlife.com internet adresini de ziyaret edebilirsiniz. Sağlıkla kalın – Microlife AG! * Bu aygıt, İngiliz Hipertansiyon Cemiyeti - British and Irish Hypertension Society (BIHS) - protokolüne uygun olarak test edilen ödül sahibi «BP 3BTO-A» modeli ile aynı ölçüm teknolojisine sahiptir. İçindekiler 1. Tansiyon Ölçümü ve Kendi Kendine Ölçüm Hakkında Önemli Gerçekler • Tansiyonumu nasıl değerlendirebilirim? 2. Aygıtın İlk Kez Kullanımı • Pillerin yerleştirilmesi • Tarih ve saatin ayarlanması • Doğru kaf seçimi • Kullanıcının seçilmesi • Standart veya MAM modunun seçilmesi • MAM modu (Tavsiye edilen) 3. Tansiyonun Ölçülmesi • Ölçüm sonucu nasıl silinir? 4. Düzensiz Kalp Atışı (IHB) Sembolünün Görünümü 5. Ekranda Trafik Işığı Göstergesi 6. Veri Belleği • Kaydedilen değerlerin görüntülenmesi • Bellek dolu • Tüm değerlerin silinmesi 7. Pil Göstergesi ve Pil değişimi • Piller neredeyse bitmiş • Piller bitmiş – pillerin değiştirilmesi • Hangi piller ve yöntem? • Şarj edilebilir pillerin kullanılması 8. Elektrik Adaptörünün Kullanılması 9. Hata İletileri 10. Güvenlik, Bakım, Doğruluk Testi ve Elden Çıkarma • Güvenlik ve koruma • Aygıtın bakımı • Kafın temizlenmesi • Doğruluk testi • Elden çıkarma 11. Garanti Kapsamı 12. Teknik Özellikler Garanti Belgesi (bkz Arka Kapak) BP A3 Plus 1. Tansiyon Ölçümü ve Kendi Kendine Ölçüm Hakkında Önemli Gerçekler  Tansiyon ile, kalp tarafından pompalanan ve atardamarlardan akan kanın basıncı ifade edilmektedir. Her zaman iki değer olan büyük tansiyon (üst) değeri ve küçük tansiyon (alt) değerinin ölçümleri yapılır.  Aygıt, aynı zamanda, nabız sayısını da gösterir (kalbin bir dakikadaki atış sayısı).  Sürekli yüksek tansiyon değerleri, sağlığınıza zarar verebilir ve doktorunuz tarafından tedavi edilmesi gerekir!  Ölçüm değerlerini her zaman doktorunuza bildirin ve olağandışı bir şey fark ettiğinizde ya da emin olmadığınız bir durum söz konusu olduğunda doktorunuza danışın. Kesinlikle tek bir tansiyon ölçüm sonucuna güvenmeyin.  Normalin üzerindeki yüksek tansiyon değerlerinden kaynaklanan birçok durum söz konusudur. Doktorunuz, bunları ayrıntılarıyla açıklayacak ve gerekli görürse tedavi edilmelerini önerecektir. İlaç tedavisinin yanı sıra, kilo vererek ve egzersiz yaparak da tansiyonunuzu düşürebilirsiniz.  Hiçbir sart altında ilaçlarınızın dozunu artırmamalı ve doktorunuza danışmadan bir tedaviye başlamamalısınız.  Bedensel efor ve kondisyona bağlı olarak, tansiyonda günden güne geniş dalgalanmalar yaşanabilir. Bu nedenle, ölçümlerinizi her zaman sakin bir ortamda ve kendinizi rahat hissettiğinizde yapmalısınız! En azından her seferinde iki kez ölçüm yapınız (sabah ve akşam) ve ölçümlerinizin ortalamasını alınız.  Kısa aralıklarla yapılan iki ölçüm sonrasında, oldukça farklı sonuçlar alınması son derece normaldir. Bundan dolayı MAM teknolojisinin kullanılmasını öneririz.  Doktorunuz ya da eczacınız tarafından veya evde yapılan ölçümler arasındaki sapmalar, söz konusu durumlar tamamen farklı olduğu için, oldukça normaldir.  Tek ölçüm yerine, bir kaç ölçüm yapmak size kan basıncınız hakkında daha güvenilir veriler sunar. Bundan dolayı MAM teknolojisinin kullanılmasını öneririz.  İki ölçüm arasında en az 15 saniyelik kısa bir ara verin.  Kardiyak aritminiz varsa, cihazı kullanmadan önce doktorunuza danışın. Ayrıca bu kullanım kılavuzunun «Düzensiz Kalp Atışı (IHB) Sembolünün Görünümü» bölümüne bakın.  Nabız göstergesi, kalp pillerinin frekansının kontrolü için uygun değildir! 41 TR  Hamilelik döneminde çok değişiklik gösterdiği için tansiyonunuzu düzenli kontrol etmeniz gerekmektedir. Bu cihaz özellikle hamilelerde ve preeklampsi kullanımları için test edilmiştir. Hamilelik sürecinde çok yüksek ölçümler alırsanız, 1 saat ara ile tekrar ölçüm yapınız. Sonuç hala çok yüksek ise, doktorunuza başvurunuz.  Tansiyonumu nasıl değerlendirebilirim? Uluslararası standartlara (ESH, ESC, JSH) göre yetişkinlerin ev tansiyon değerlerinin sınıflandırma tablosu. Veriler, mmHg cinsindendir. Düzey 1. tansiyon normal 2. tansiyon en iyi aralıkta 3. tansiyon yükseldi 4. tansiyon çok yüksek 5. tansiyon tehlikeli biçimde yüksek Küçük Büyük Tansiyo Tansiyon n Öneri < 120 < 74 Kendiniz kontrol ediniz 120 - 129 74 - 79 Kendiniz kontrol ediniz 130 - 134 80 - 84 Kendiniz kontrol ediniz 135 - 159 85 - 99 Tıbbi kontrolden geçiniz ≥ 160 ≥ 100 Acilen tıbbi kontrolden geçiniz! Değerlendirmeyi belirleyen, daha yüksek olan değerdir. Örneğin: Kan basıncı 140/80 mmHg değeri veya değeri 130/90 mmHg, «tansiyon oldukça yüksek» gösterir. 2. Aygıtın İlk Kez Kullanımı Pillerin yerleştirilmesi Aygıtın ambalajını açtıktan sonra, ilk önce pilleri yerleştirin. Pil bölmesi 4, aygıtın alt tarafındadır. Pilleri (4 x AA 1.5 V boyutunda) yerleştirin; bunu yaparken kutupların gösterildiği gibi doğru konumda bulunmasına dikkat edin. Tarih ve saatin ayarlanması 1. Yeni piller takılınca, yıl sayısı ekranda yanıp söner. M-düğmesine AT basarak yılı ayarlayabilirsiniz. Ayı teyit edip ayarlamak için, zaman düğmesine AK basın. 2. M-düğmesini kullanarak şimdi ayı ayarlayabilirsiniz. Günü teyit etmek ve ayarlamak için, zaman düğmesine basın. 42 3. Günü, saati ve dakikayı ayarlamak için, lütfen, yukarıdaki talimatları uygulayın. 4. Dakikayı ayarlayıp zaman düğmesine bastıktan sonra, tarih ve saat ayarlanır ve zaman görüntülenir. 5. Tarih ve saati değiştirmek isterseniz, zaman düğmesine basın ve yıl sayısı yanıp sönünceye kadar 3 saniye basılı tutun. Şimdi yeni değerleri yukarıda açıklandığı şekilde girebilirsiniz. Doğru kaf seçimi Microlife değişik ebatlarda kaflar sunar. Üst kolunuzun çevresine uygun kaf boyutunu seçin (üst kolunuzun ortasını en uygun şekilde kavrayarak ölçülür). Kaf boyutu üst kolunuzun çevresi için S 17 - 22 cm M 22 - 32 cm M-L 22 - 42 cm L 32 - 42 cm L - XL 32 - 52 cm Şekil verilmiş «Easy» kaflar opsiyonel olarak mevcuttur, daha iyi uyum ve konfor için. Sadece Microlife kaf kullanın!  Ürünle birlikte verilen kaf 6 uymazsa, yerel Microlife Servisi ile görüşün.  Kaf bağlantısını 7 olabildiğince kaf soketine 3 yerleştirerek, kafı aygıta bağlayın. Kullanıcının seçilmesi Bu cihaz 2 farklı kullanıcı için sonuçları saklamaya izin verir.  Her ölçümden önce hedeflenen kullanıcı için kullanıcı anahtarını 9 ayarlayın: kullanıcı 1 veya kullanıcı 2.  Kullanıcı 1: Kullanıcı anahtarını 9 kullanıcı 1' e gelecek şekilde yukarı doğru çekin.  Kullanıcı 2: Kullanıcı anahtarını 9 kullanıcı 2' ye gelecek şekilde aşağı doğru çekin. İlk kullanacak kullanıcı için lütfen kullanıcı 1' i seçin. Standart veya MAM modunun seçilmesi Bu aygıt, gerek standart (standart tek ölçüm) gerekse MAM modunu (otomatik üçlü ölçüm) seçmenizi sağlar. Standart modu seçmek için, aygıt tarafındaki MAM anahtarını 8 aşağı doğru konum «1» e getirin ve MAM modunu seçmek için ise, aynı anahtarı yukarı doğru konum «3» e getirin.    MAM modu (Tavsiye edilen)  MAM modunda, 3 otomatik ardışık ölçüm yapılır ve sonuç otomatik olarak değerlendirilip görüntülenir. Tansiyon sürekli bir dalgalı seyir izlediğinden dolayı, bu şekilde alınan ölçüm sonucu, tek bir ölçüm sonucuna kıyasla daha güvenilirdir.  3-ölçümü seçtiğinizde, MAM sembolü BL ekranda görüntülenir.  Üç ölçümden halihazırda hangisinin yapıldığını göstermek için, ekranın sağ alt bölümünde 1, 2 ya da 3 rakamı görüntülenir.  Ölçümler arasında 15 saniye aralık bulunmaktadır. Bir geri sayım kalan zamanı göstermektedir.  Münferit sonuçlar görüntülenmez. Tansiyonunuz, sadece 3 ölçümün hepsi yapıldıktan sonra görüntülenir.  Ölçümler arasında kafı çıkarmayın.  Münferit ölçümlerden birinde sorun yaşanırsa, dördüncü bir ölçüm otomatik olarak yapılır. 3. Tansiyonun Ölçülmesi Güvenilir bir ölçüm yapılması için kontrol listesi 1. Ölçümden hemen önce, hareket etmekten kaçının; herhangi bir şey yemeyin ve sigara içmeyin. 2. Sırt destekli bir sandalyeye oturun ve 5 dakika süre ile bekleyin. Ayaklarınızı yerde düz bir şekilde konumlandırın, ayak ayak üstüne atmayınız. 3. Her zaman aynı koldan ölçüm yapın (normalde sol kol). Doktorlara hastaların ilk ziyaretlerinde gelecekte hangi koldan ölçüm almaları gerektiğini belirlemek için genellikle iki koldan birden ölçüm almaları tavsiye edilir. Yüksek kan basıncını veren kol seçilmelidir. 4. Üst kolunuzu sıkıca kavrayan giysileri çıkarın. Basınç oluşturmaması için, gömlek kollarını kıvırmayın - düz bırakıldıklarında kaf işlevini engellemezler. 5. Her zaman doğru ölçüdeki kafın (ölçü kafın üzerindedir) kullanıldığından emin olun.  Kaf, üst kolunuzu yeterince kavrasın; ancak, çok sıkı olmasın.  Kafın iç dirseğinizin 1-2 cm yukarısına yerleştirildiğinden emin olun.  Kafın üzerine konumlanmış olan atardamar işareti (yaklaşık 3 cm uzunluğunda) kolunuzun iç kısmından aşağı doğru inen atardamarın üzerinde olmalıdır.  Rahatça ölçüm yapılması için, kolunuzu destekleyin.  Kafın kalbinizle aynı yükseklikte olmasını sağlayın. 6. Ölçüm işlemini başlatmak için, AÇ/KAPA düğmesine 1 basın. BP A3 Plus 7. Kaf şimdi otomatik olarak şişecektır. Gevşeyin; ölçüm sonucu görüntüleninceye kadar hareket etmeyin ve kol kaslarınızı kasmayın. Normal biçimde soluk alıp verin ve konuşmayın. 8. Doğru basınca ulaşıldığında, pompalama işlemi durur ve basınç dereceli olarak düşer. İstenilen basınca ulaşılamamışsa, aygıt kafa otomatik olarak biraz daha hava pompalar. 9. Ölçüm sırasında nabız göstergesi BT yanıp söner. 10.Büyük tansiyon AO ile küçük tansiyonu AP ve nabzı AQ içeren sonuç görüntülenir. Broşürdeki diğer görüntülerle ilgili açıklamaları da dikkate alınız. 11.Ölçüm bittiğinde kafı çıkarınız. 12.Aygıtı kapatın. (Yaklaşık 1 dakika sonra monitör otomatik olarak kapanır). Ölçüm sonucu nasıl silinir? Ölçüm sonucu göründüğü anda, ekranda «M» BO yanıp sönene kadar AÇ/KAPA tuşuna 1 basılı tutunuz. M tuşuna AT basarak ölçüm sonucunun silinmesini onaylayınız. AÇ/KAPA düğmesine basarak, aygıtı istediğiniz zaman kapatabilirsiniz (örneğin, kendinizi rahat hissetmiyorsanız ya da rahatsız edici bir basınç algılanması halinde). Büyük tansiyon çok yüksek ise, basıncı münferit olarak ayarlamak yararlı olabilir. Pompalamak suretiyle monitördeki değer yaklaşık olarak 30 mmHg (ekranda gösterilir) seviyesine ulaştıktan sonra AÇ/KAPA düğmesine basın. Basınç, beklenen büyük tansiyon değerinin üzerinden yaklaşık 40 mmHg daha yükseğe ulaşıncaya kadar düğmeyi basılı tutun - daha sonra düğmeyi serbest bırakın.   4. Düzensiz Kalp Atışı (IHB) Sembolünün Görünümü Bu sembol BM düzensiz bir kalp atışının tespit edildiğini gösterir. Bu durumda, ölçülen kan basıncı gerçek kan basıncı değerlerinizden sapabilir. Ölçümü tekrarlamanız önerilir. IHB sembolünün tekrarlı görünmesi durumunda doktor için bilgi Bu cihaz, kan basıncı ölçümü sırasında nabzı ölçen ve kalp atış hızının düzensiz olduğunu gösteren bir osilometrik tansiyon aletidir. 5. Ekranda Trafik Işığı Göstergesi Ekranın sol tarafında AR ki barlar tansiyon değerinin hangi seviyede olduğunu göstermektedir. Barın yüksekliğine bağlı olarak 43 TR okunan değer; optimum (yeşil), yüksek(sarı), çok yüksek(turuncu) veya tehlikeli derecede yüksek(kırmızı) olarak değerlendirilir. Kategoriler, uluslarası standartlar (ESH, ESC, JSH) tablosunda belirlenmiş olan 4 aralığı belirtmektedir «Bölüm 1.». 6. Veri Belleği Bu cihaz otomatik olarak 2 kullanıcı için ayrı ayrı 99 kayıt yapabilmektedir. Kaydedilen değerlerin görüntülenmesi Kullanıcı anahtarı 9 ile kullanıcı 1 veya 2'yi seçin. Aygıt kapanınca M-düğmesine AT kısaca basın. Ekranda, önce «M» BO simgesi ve «A» tüm saklı değerlerin ortalamasını gösterir. M-düğmesine tekrar basıldığında, bir önceki değer görüntülenir. M-düğmesine üst üste basarak, bir kayıtlı değerden diğerine geçebilirsiniz. Bellek dolu Her kullanıcı için 99 ölçüm sonucunu içeren hafıza kapasitesinin aşılmamasına dikkat ediniz. 99 ölçümlük hafıza dolduğunda, 100. ölçüm en eski ölçüm verisi silinerek kaydedilir. Sonuçlar, maksimum hafıza kapasitesine erişmeden doktor tarafından incelenmelidir, aksi takdirde veriler kaybolur.  Tüm değerlerin silinmesi Doğru kullanıcının seçili olduğundan emin olun. 1. Cihaz kapalıyken, kullanıcı anahtarı 9 1 veya 2 konumuna getirin. 2. M-düğmesine AT ekranda «CL» ibaresi görünene kadar basılı tutun ve göründüğünde düğmeye basmayı bırakın. 3. «CL» ibaresi yanıp sönerken M-düğmesine basın. Böylelikle seçili kullanıcının tüm verileri kalıcı olarak silinmiş olur. Silme İptali: ibaresi ekrandayken AÇ/KAPA düğmesine 1 basın. Münferit değerler, silinemez.   7. Pil Göstergesi ve Pil değişimi Piller neredeyse bitmiş Piller, yaklaşık olarak ¾ oranında kullanıldığında, aygıt açılır açılmaz kullanılmış pil simgesi AM yanıp söner (kısmen dolu bir pil görüntülenir). Her ne kadar aygıt, güvenilir ölçüm yapmaya devam etse de pilleri değiştirmeniz gerekir. 44 Piller bitmiş – pillerin değiştirilmesi Piller bittiğinde, aygıt açılır açılmaz pil simgesi AM yanıp söner (bitmiş bir pil görüntülenir). Piller bitttiğinde, artık ölçüm yapamazsınız ve pilleri değiştirmeniz gerekir. 1. Aygıtın altındaki pil bölmesini 4 açın. 2. Pilleri değiştirin – bölmedeki simgelerle gösterildiği şekilde kutupların doğru konumda olup olmadığına dikkat edin. 3. Tarih ve saati ayarlamak için, «Bölüm 2.» de açıklanan yöntemi uygulayın. Tarih ve saatin sıfırlanması gerekmesine karşın, bellek tüm değerleri korur – bu nedenle, piller değiştirildikten sonra, yıl sayısı otomatik olarak yanıp söner. Hangi piller ve yöntem? Lütfen, 4 adet yeni ve uzun ömürlü 1.5V, AA alkalin pili kullanın. Kullanım süresi geçen pilleri kullanmayın. Aygıt uzun bir süre kullanılmayacaksa, pilleri çıkarın. Şarj edilebilir pillerin kullanılması Aygıtı şarj edilebilir pilleri kullanarak da çalıştırabilirsiniz. Lütfen, sadece «NiMH» türünde yeniden kullanılabilir pilleri kullanın! Pil simgesi (bitmiş pil) görüntülendiğinde, pillerin çıkarılıp şarj edilmesi gerekmektedir! Zarar görebileceklerinden, pillerin aygıtın içerisinde bırakılmaması gerekmektedir (kapalı olsa bile aygıtın düşük kullanımının bir sonucu olarak tamamen boşalırlar). Bir hafta ya da daha uzun bir süre kullanmayı düşünmüyorsanız, her zaman şarj edilebilir pilleri çıkarın! Piller, tansiyon ölçüm aletinde şarj EDİLEMEZ! Bu pilleri harici bir şarj aygıtında şarj edin; bununla birlikte, şarj, bakım ve dayanıklılık konusundaki bilgileri dikkate alın!         8. Elektrik Adaptörünün Kullanılması Bu aygıtı Microlife elektrik adaptörü kullanarak da çalıştırabilirsiniz (DC 6V, 600 mA). Elektrik geriliminiz için mevcut olan uygun orijinal aksesuar olarak sadece Microlife elektrik adaptörü kullanın. Elektrik adaptörünün ya da kablonun zarar görmediğinden emin olun. 1. Adaptör kablosunu, tansiyon ölçüm aletinin elektrik adaptör soketine 5 takın.   2. Adaptör fişini duvar prizine takın. Elektrik adaptörü bağlandığında, artık pil enerjisi kullanılmaz. 9. Hata İletileri Ölçüm sırasında hata meydana gelirse, ölçüm işlemi durdurulur ve bir hata iletisi, örneğin «ERR 3», görüntülenir. Hata Açıklama «ERR 1» Sinyal çok zayıf «ERR 2» Hata sinyali BN Olası nedeni ve çözümü Kaf nabız sinyalleri çok zayıf. Kafı yeniden takın ve ölçümü tekrarlayın.* Ölçüm sırasında, kaf, hareket etmekten ya da adale kasılmasından kaynaklanan hata sinyalleri algıladı. Kolunuzu kımıldatmadan ölçümü tekrarlayın. «ERR 3» Kafta Kaf uygun basınç oluşturulamıyor. BK basınç yok Kaçak meydana gelmiş olabilir. Kafın doğru takılıp takılmadığını ve çok gevşek olup olmadığını konrol edin. Gerekirse, pilleri değiştirin. Ölçümü tekrarlayın. «ERR 5» Anormal Ölçüm sinyalleri doğru değil ve bu sonuç nedenle sonuç görüntülenemiyor. Güvenilir ölçüm yapılabilmesi için, kontrol listesini okuyun ve ölçümü tekrarlayın.* «ERR 6» MAM Modu MAM modunda ölçüm yapılırken, nihai sonucun alınmasını imkansız kılan birçok hata oluştu. Güvenilir ölçüm yapılabilmesi için, kontrol listesini okuyun ve ölçümü tekrarlayın.* «HI» Nabız ya da Kaf basınç çok yüksek (299 mmHg'nin kaf basıncı üzerinde) YA DA nabız çok yüksek (dakiçok yüksek kada 200 atıştan fazla). 5 dakika gevşeyin ve ölçümü tekrarlayın.* «LO» Nabız çok Nabız çok düşük (dakikada 40 atıştan düşük daha düşük). Ölçümü tekrarlayın.* * Bu veya başka bir problem tekrarlar ise, lütfen acilen doktorunuza başvurunuz. Sonuçların anormal olduğunu düşünüyorsanız, lütfen, «Bölüm 1.» deki bilgileri dikkatli biçimde okuyun.  BP A3 Plus 10. Güvenlik, Bakım, Doğruluk Testi ve Elden Çıkarma  Güvenlik ve koruma  Kullanım için talimatları okuyunuz. Bu doküman cihazın güvenli kullanımı için önemli bilgiler içermektedir. Lütfen cihazı kullanmadan önce bu dökümanı tamamen okuyunuz ve gelecekte tekrar başvurmak üzere saklayınız.  Bu ürün, sadece bu broşürde açıklanan amaçlar çerçevesinde kullanılabilir. İmalatçı, yanlış uygulamadan kaynaklanan zarar ziyan için sorumlu tutulamaz.  Aygıt, hassas parçalara sahiptir ve dikkatli biçimde kullanılmalıdır. «Teknik Özellikler» bölümünde açıklanan saklama ve çalıştırma koşullarını göz önünde bulundurun!  Aşağıdaki durumlara maruz kalmasına engel olun: - su ve nem - aşırı sıcaklıklar - darbe ve düşürülme - kir ve toz - doğrudan güneş ışığı - sıcak ve soğuk  Kaf, hassastır ve dikkatli biçimde kullanılmalıdır.  Bu cihaz ile ölçüm yaparken başka çeşit kaf veya kaf konnektörü kullanmayınız ya da değiştirmeyiniz.  Kafı cihaza taktıktan sonra pompalayın.  Aygıtı cep telefonları ya da radyo donanımları gibi güçlü elektromanyetik alanlara yakın yerlerde kullanmayın. Aygıtı kullanırken bu tip cihazlardan minimum 3.3 metre uzakta olun.  Hasar gördüğünü düşünüyorsanız ya da herhangi bir anormal durum sezdiyseniz, aygıtı kullanmayın.  Aygıtı kesinlikle açmayın.  Aygıtın uzun bir süre kullanılmaması durumunda, pillerin çıkarılması gerekir.  Broşürün ilgili bölümlerindeki diğer güvenlik talimatlarını da okuyun.  Bu cihaz tarafından verilen ölçüm sonuçları bir teşhis olarak değerlendirilmemelidir. Mutlaka doktorunuza danışınız. Özellikle, hasta semptomları cihaz ölçümüyle uyuşmuyorsa sadce ölçüm sonucuna güvenmeyin. Diğer semptomları ve hastanın geri bildirimini göz önünde bulundurarak doktorunuzla görüşün veya gerekiyorsa ambulans çağırın. Çocukların denetimsiz bir şekilde ürünü kullanmalarına izin vermeyin; bazı parçalar, yutulabilecek kadar küçüktür. Aygıtın kablo veya borularının olması nedeni ile yaratabileceği boğulma riskinin farkında olun. 45 TR Aygıtın bakımı Aygıtı sadece yumuşak ve kuru bir bezle temizleyin. Kafın temizlenmesi Kaf üzerindeki noktaları sabunlu su ile nemlendirilmiş bezle dikkatli bir şekilde gideriniz. UYARI: Kafı çamaşır veya bulaşık makinesinde yıkamayınız!  Doğruluk testi Her 2 yılda bir ya da mekanik darbeye maruz kalması (örneğin, düşürülmesi) durumunda, ürünün doğru çalışıp çalışmadığının test edilmesini öneririz. Test işlemini ayarlamak için, lütfen, yerel Microlife-Servisi ile görüşün (bkz ön söz). Elden çıkarma Piller ve elektronik ürünler, çöpe atılmamalı; ancak, yürürlükteki yönetmeliklere uygun olarak elden çıkarılmalıdır. 11. Garanti Kapsamı Bu aygıt, satın alındığı tarihten itibaren 5 yıl garanti kapsamındadır. Bu garanti süresi içinde, bizim takdirimize bağlı olarak, Microlife arızalı ürünü ücretsiz olarak onaracak veya değiştirecektir. Aygıtın açılması ya da üzerinde değişiklik yapılması, garantiyi geçersiz kılar. Aşağıdaki öğeler garanti kapsamı dışındadır:  Nakliye maliyetleri ve nakliye riskleri.  Yanlış uygulamadan veya kullanım talimatlarına uyulmamasından kaynaklanan hasar.  Sızdıran pillerden kaynaklanan hasar.  Kaza veya yanlış kullanımdan kaynaklanan hasar.  Ambalaj / depolama malzemesi ve kullanım talimatları.  Düzenli kontroller ve bakım (kalibrasyon).  Aksesuarlar ve aşınan parçalar: Piller, güç adaptörü (isteğe bağlı). Kaf 2 yıl boyunca fonksiyonel bir garanti (hava kesesinin sıkılığı) kapsamındadır. Garanti servisinin gerekli olması halinde, lütfen ürünün satın alındığı bayiye veya yerel Microlife servisinize başvurun. Yerel Microlife hizmetinize web sitemizden ulaşabilirsiniz: www.microlife.com/support 46 Tazminat ürünün değeri ile sınırlıdır. Tüm ürün orijinal fatura ile birlikte iade edilirse garanti verilecektir. Garanti kapsamındaki onarım veya değiştirme, garanti süresini uzatmaz veya yenilemez. Tüketicilerin yasal talepleri ve hakları bu garanti ile sınırlı değildir. 12. Teknik Özellikler Çalışma koşulları: 10 - 40 °C / 50 - 104 °F %15 - 95 maksimum bağıl nem Saklama koşulları: -20 - +55 °C / -4 - +131 °F %15 - 95 maksimum bağıl nem Ağırlık: 368 g (piller dahil) Boyutlar: 143 x 85 x 58 mm Ölçüm yöntemi: osilometrik, Korotkoff yöntemine uygun: Aşama I büyük tansiyon, Aşama V küçük tansiyon Ölçüm aralığı: 20 - 280 mmHg – tansiyon dakikada 40 - 200 atış – nabız Kaf basıncı görüntüleme aralığı: 0 - 299 mmHg Çözünürlük: 1 mmHg Statik doğruluk: ±3 mmHg aralığında basınç Nabız doğruluğu: ±ölçülen değerin %5'i Gerilim kaynağı: 4 x 1.5 V alkalin piller; boyut AA Elektrik adaptörü DC 6V, 600 mA (isteğe bağlı) Pil ömrü: Yaklaşık 920 ölçüm (Yeni pillerle) IP sınıfı: IP20 İlgili standartlar: EN 1060-1 /-3 /-4; IEC 60601-1; IEC 60601-1-2 (EMC); IEC 60601-1-11 Beklenen servis Cihaz: 5 yıl veya 10000 ölçüm ömrü: Aksesuarlar: 2 yıl Bu cihaz, 93/42/EEC Tıbbi Cihaz Yönetmenliği gereksinimleri ile uyumludur. Teknik özelliklerin değiştirilmesi hakkı saklıdır. BP A3 Plus 47 TR Microlife BP A3 Plus 1 2 3 4 5 6 7 8 9 AT AK Botão ON/OFF Visor Entrada da braçadeira Compartimento das pilhas Entrada do adaptador Braçadeira Conector da braçadeira Interruptor MAM Botão de utilizador Botão M (Memória) Botão das horas Visor AL Indicador do utilizador AM Visualização das pilhas AN Data/Hora AO Pressão sistólica AP Pressão diastólica AQ Frequência cardíaca AR Indicador luminoso do nível da pressão arterial AS Intervalo de tempo MAM BT Indicador da pulsação BK Indicador da braçadeira BL Modo MAM BM Símbolo de batimento cardíaco irregular (IHB) BN Indicador do movimento do braço BO Valor guardado Leia atentamente este manual de instruções antes de utilizar o dispositivo. Peça aplicada tipo BF Manter seco 48 PT Uso pretendido: Este tensiómetro oscilométrico destina-se a medir tensão arterial não invasiva em pessoas com 12 anos ou mais. É clinicamente testado em pacientes com hipertensão, hipotensão, diabetes, gravidez, pré-eclâmpsia, aterosclerose, doença renal em fase terminal, obesidade e idosos. Estimado cliente, Este dispositivo foi desenvolvido com a colaboração de peritos na área da medicina e os ensaios clínicos realizados comprovam a sua elevada precisão na medição.* Se tiver alguma questão, problema ou se pretender encomendar peças sobresselentes, não hesite em contactar o seu distribuidor local da Microlife. A farmácia da sua zona poderá indicar a morada do distribuidor Microlife no seu país. Pode também visitar o site www.microlife.com onde encontrará toda a informação útil sobre os produtos Microlife. Mantenha-se saudável – Microlife AG! * Este dispositivo utiliza a mesma tecnologia de medição utilizada no modelo «BP 3BTO-A» já premiado, sendo um modelo testado em conformidade com o protocolo BIHS (British and Irish Hypertension Society). Índice 1. Aspetos importantes sobre a pressão arterial e a automedição • Como avaliar a minha pressão arterial? 2. Utilizar o dispositivo pela primeira vez • Inserir as pilhas • Definir a data e hora • Escolher a braçadeira adequada • Selecção do utilizador • Selecionar o modo standard (padrão) ou modo MAM • Modo MAM (altamente recomendado) 3. Medir a pressão arterial • Como não guardar um resultado 4. Visualização do símbolo de batimento cardíaco irregular (IHB) 5. Mostrador com indicador luminoso do nível da pressão arterial (sistema «semáforo») 6. Memorização de dados • Visualizar valores guardados • Memória cheia • Limpar todos os valores 7. Indicador de carga e substituição de pilhas • Pilhas quase descarregadas • Pilhas descarregadas – substituição • Quais as pilhas a utilizar e quais os procedimentos a efetuar? • Utilizar pilhas recarregáveis 8. Utilizar um adaptador 9. Mensagens de erro 10. Segurança, cuidados, teste de precisão e eliminação de resíduos • Segurança e proteção • Cuidados a ter com o dispositivo • Limpeza da braçadeira • Teste de precisão • Eliminação de resíduos 11. Garantia 12. Especificações técnicas Cartão de garantia (ver contracapa) BP A3 Plus 1. Aspetos importantes sobre a pressão arterial e a auto-medição  A pressão arterial é a pressão da circulação sanguínea nas artérias gerada pelos batimentos cardíacos. É sempre efetuada a medição de dois valores, o valor máximo pressão arterial sistólica e o valor mínimo pressão arterial diastólica.  Este aparelho também indica a frequência cardíaca (ou seja, o número de batimentos cardíacos por minuto).  Valores de pressão arterial constantemente elevados podem prejudicar a saúde e têm de ser acompanhados pelo seu médico!  Indique sempre os valores das medições obtidos ao seu médico e informe-o se detectar qualquer irregularidade ou em caso de dúvida. Nunca confie numa leitura de pressão arterial isolada.  Existem diversas causas para valores de tensão arterial demasiado elevados. O seu médico poderá explicá-las mais detalhadamente e propor o respectivo tratamento, se necessário. Para além da medicação, a perda de peso e o exercício físico podem também contribuir para diminuir a tensão arterial.  Em nenhuma circunstância deve alterar as dosagens dos fármacos ou iniciar um tratamento sem consultar o seu médico.  Dependendo das condições físicas e do esforço físico, a tensão arterial está sujeita a grandes flutuações com o decorrer do dia. Deste modo, deverá efectuar sempre as medições num ambiente calmo quando estiver descontraído! Faça sempre pelo menos duas medições (de manhã e à noite), e faça a média das leituras.  É perfeitamente normal que duas medições efectuadas sucessivamente apresentem resultados significativamente diferentes. Recomenda-se portanto o uso da tecnologia MAM.  As diferenças de valores verifiadas entre as medições efetuadas pelo médico ou realizadas na farmácia e as medições efetuadas em casa são perfeitamente normais, uma vez que estas situações são completamente diferentes.  Diversas medições dão resultados mais fiáveis da pressão arterial do que uma única medição. Recomenda-se portanto o uso da tecnologia MAM.  Faça um pequeno intervalo de, pelo menos, 15 segundos entre duas medições.  Se sofre de arritmia cardíaca, consulte o seu médico antes de usar o dispositivo. Consulte também o capítulo «Visualização 49 PT do símbolo de batimento cardíaco irregular (IHB)» neste manual do utilizador.  A visualização da pulsação não se aplica no controlo da frequência dos «pacemakers»!  Se estiver grávida, deve avaliar a sua tensão arterial regularmente, pois pode mudar drasticamente durante este tempo. Este tensiómetro é especialmente testado para utilização durante a gravidez e pré-eclâmpsia. Quando são detetadas leituras elevadas e irregulares durante a gravidez, passado algum tempo deve repetir a medição (por exemplo, 1 hora). Se a leitura permanecer muito alta, consulte o seu médico ou ginecologista.  Como avaliar a minha pressão arterial? Quadro de classificação da tensão arterial medida em casa em adultos de acordo com as directrizes internacionais da (ESH, ESC, JSH). Valores em mmHg. Nível 1. pressão arterial normal 2. pressão arterial ideal 3. tensão arterial elevada 4. pressão arterial muito alta 5. tensão arterial extremamente alta com gravidade Sistólica < 120 Diastólica < 74 Recomendações Auto-medição 120 - 129 74 - 79 Auto-medição 130 - 134 80 - 84 Auto-medição 135 - 159 85 - 99 ≥ 160 ≥ 100 Obtenha aconselhamento médico Consulte o médico com urgência! O valor mais elevado é o valor que determina o resultado da análise Exemplo: uma leitura de 140/80 mmHg ou 130/90 mmHg indica «tensão arterial muito alta». 2. Utilizar o dispositivo pela primeira vez Inserir as pilhas Após ter desempacotado o dispositivo, comece por inserir as pilhas. O compartimento das pilhas 4 está localizado na parte inferior do dispositivo. Insira as pilhas (4 x 1,5 V pilhas, tamanho AA) e respeite a polaridade indicada. 50 Definir a data e hora 1. Quando as novas pilhas estiverem colocadas, aparecerá no mostrador um número a piscar que corresponde ao ano. Pode definir o ano pressionando o botão M AT. Para efetuar a confirmação e, em seguida, definir o mês, pressione o botão das horas AK. 2. Pode agora definir o mês utilizando o botão M. Pressione o botão das horas para efetuar a confirmação e, em seguida, defina o dia. 3. Siga as instruções acima para definir o dia, as horas e os minutos. 4. Quando tiver definido os minutos e pressionado o botão das horas, a data e hora são definidas e aparece a indicação da hora. 5. Se pretender alterar a data e hora, pressione e mantenha pressionado o botão das horas durante aproximadamente 3 segundos até que o número correspondente ao ano comece a piscar. Agora pode introduzir os novos valores, conforme descrito acima. Escolher a braçadeira adequada A Microlife tem disponíveis diversos tamanhos de braçadeira. Escolha o tamanho de braçadeira adequado à circunferência da parte superior do braço (que deve ser medida com a braçadeira ajustada no meio da parte superior do braço). Tamanho da para uma circunferência da parte superior do braçadeira braço S 17 - 22 cm M 22 - 32 cm M-L 22 - 42 cm L 32 - 42 cm L - XL 32 - 52 cm Braçadeiras rígidas «Easy» estão disponíveis como acessório opcional para uma melhor adaptação ao braço e maior conforto na medição. Utilize apenas braçadeiras da Microlife!  Contacte o seu local Assistência da Microlife, caso a braçadeira fornecida 6 não seja adequada.  Ligue a braçadeira ao aparelho introduzindo completamente o conector da braçadeira 7 na respectiva entrada 3. Selecção do utilizador Este dispositivo guarda os resultados de 2 utilizadores individuais.  Antes de cada medição marque o botão 9 para o utilizador que pretende: 1 ou 2.  Utilizador 1: desloque o botão do utilizador 9 para cima até ao símbolo do utilizador 1.    Utilizador 2: desloque o botão do utilizador 9 para baixo até ao símbolo do utilizador 2. A primeira pessoa a medir deve seleccionar o utilizador 1.  Selecionar o modo standard (padrão) ou modo MAM Este aparelho permite optar entre o modo padrão (uma única medição padrão) e o modo MAM (medição tripla automática). Para seleccionar o modo padrão, faça deslizar para baixo o interruptor MAM 8 situado na parte lateral do aparelho, na direcção da posição «1» e para seleccionar o modo MAM, faça deslizar este interruptor para cima, em direcção à posição «3». Modo MAM (altamente recomendado)  No modo MAM, são efectuadas automaticamente 3 medições consecutivas e, em seguida, o resultado é automaticamente analisado e apresentado. Uma vez que a tensão arterial está constantemente a sofrer variações, um resultado determinado utilizando este método é mais fiável do que um resultado obtido através de uma única medição.  Quando escolhe as 3 medições, o símbolo MAM BL aparece no mostrador.  No canto inferior direito do mostrador aparece 1, 2 ou 3 para indicar qual das 3 medições está actualmente a ser efectuada.  Existe uma pausa de 15 segundos entre as medições. Uma contagem decrescente indica o tempo restante.  Os resultados individuais não são apresentados. A tensão arterial apenas será apresentada após terem sido efectuadas as 3 medições.  Não retire a braçadeira no período entre as medições.  Se uma das medições individuais suscitar dúvidas, será automaticamente efectuada uma quarta medição. 3. Medir a pressão arterial Check-list para efetuar uma medição correta 1. Não deve comer, fumar nem exercer qualquer tipo de esforço físico imediatamente antes de efetuar a medição. 2. Sente-se numa cadeira apoiada nas costas e relaxe por 5 minutos. Mantenha os pés no chão e não cruze as pernas. 3. Deve efectuar a medição sempre no mesmo braço (normalmente o braço esquerdo). O médico deve efectuar as medições em ambos os braços do doente na primeira consulta para determinar qual o braço a utilizar de futuro. A medição deve ser efectuada no braço com a leitura mais elevada. BP A3 Plus 4. Retire qualquer peça de vestuário que possa estar justa na parte superior do braço. Para evitar que seja exercida pressão, as mangas da camisa não devem estar enroladas para cima, uma vez que não interferem com a braçadeira se estiverem esticadas normalmente. 5. Assegure-se sempre de que está a usar uma braçadeira de tamanho correcto (indicado na braçadeira).  Ajuste bem a braçadeira, mas não aperte demasiado.  A braçadeira deverá estar colocada 1-2 cms acima do seu cotovelo.  A marca da artéria na braçadeira (barra com aproximadamente 3 cm), deve ser colocada sobre a artéria localizada no lado interior do braço.  Coloque o braço assente numa superfície, para que fique descontraído.  Certifique-se de que a braçadeira fica à mesma altura do coração. 6. Pressione o botão ON/OFF 1 para iniciar a medição. 7. A braçadeira começa a encher-se automaticamente. Descontraia, não se mova e não contraia os músculos do braço enquanto o resultado da medição não for apresentado. Respire normalmente e não fale. 8. Quando a pressão correta for atingida, a braçadeira deixa de encher e a pressão desce gradualmente. Caso a pressão necessária não tenha sido atingida, o aparelho introduz automaticamente mais ar na braçadeira. 9. Durante a medição o indicador da pulsação BT aparece a piscar no visor. 10.O resultado da pressão sistólica AO e diastólica AP bem como a pulsação AQ aparecem no visor. Consulte também as informações contidas neste livro sobre os outros símbolos. 11.Remova a braçadeira após efectuar a medição. 12.Desligue o aparelho. (O monitor desliga-se automaticamente decorrido cerca de 1 min.) Como não guardar um resultado Quando o resultado aparecer no visor, mantenha a pressão no botão ON/OFF 1 até «M» BO começar a piscar. Confirme a anulação da leitura premindo o botão M AT. É possível interromper a medição em qualquer altura pressionando o botão ON/OFF (por exemplo, se sentir-se incomodado ou desconfortável com a sensação de pressão).   51 PT Se a tensão arterial sistólica costuma ser muito elevada, poderá constituir uma vantagem definir a pressão individualmente. Pressione o botão ON/OFF após o valor no monitor ter aumentado até um nível correspondente a aproximadamente 30 mmHg (visível no mostrador). Mantenha o botão pressionado até a pressão atingir cerca de 40 mmHg acima do valor sistólico esperado e, em seguida, solte o botão. 4. Visualização do símbolo de batimento cardíaco irregular (IHB) Este símbolo BM indica que um batimento cardíaco irregular foi detetado. Nesse caso, a tensão arterial medida pode divergir dos valores reais da tensão arterial. É recomendável repetir a medição. Informação para o seu médico em caso de visualização repetida do símbolo IHB Este dispositivo é um tensiómetro oscilométrico que também realiza a medição da pulsação durante a medição da tensão arterial, e indica quando a frequência cardíaca está irregular. 5. Mostrador com indicador luminoso do nível da pressão arterial (sistema «semáforo») As barras localizadas no lado esquerdo do mostrador AR indicam o limite dos valores obtidos. Dependendo da altura da barra, os valores classificam-se por óptimos (verde), elevados (amarelo), demasiado elevados (laranja), ou perigosos (vermelho). A classificação corresponde aos 4 limites na escala tal como definidos pelas directrizes internacionais (ESH, ESC, JSH), como descrito na «Secção 1.». 6. Memorização de dados Este dispositivo guarda automaticamente até 99 valores de medição para cada um dos 2 utilizadores. Visualizar valores guardados Selecione utilizador 1 ou 2 com o botão do utilizador 9. Pressione o botão M AT durante breves instantes, quando o dispositivo estiver desligado. Primeiro o dispositivo apresenta o símbolo «M» BO e «A», que representa a média de todos os valores armazenados. Se pressionar novamente o botão M, será apresentado o valor anterior. Pressionando o botão M várias vezes é possível alternar entre os valores guardados. 52 Memória cheia Assegure-se de que não ultrapassa as 99 memórias por utilizador. Quando as 99 memórias estão cheias, o valor mais antigo é automaticamente substituído pelo valor da 100ª medição. Os valores deverão ser analisados por um médico antes de ser atingida a capacidade da memória, caso contrário os dados perder-se-ão. Limpar todos os valores Certifique-se que o utilizador correto está activado. 1. Seleccione o utilizador 1 ou 2 com o botão do utilizador 9, com o dispositivo desligado. 2. Prima o botão M AT até aparecer «CL» e solte o botão. 3. Prima o botão M enquanto «CL» permanece a piscar para limpar permanentemente todos os valores do utilizador seleccionado. Anular a acção: prima o botão ON/OFF 1 enquanto «CL» permanece a piscar. Não é possível apagar valores individualmente.    7. Indicador de carga e substituição de pilhas Pilhas quase descarregadas Quando tiverem sido utilizados cerca de ¾ da carga das pilhas, o símbolo de pilha AM será apresentado a piscar, ao ligar o aparelho (é apresentada uma pilha parcialmente preenchida). Ainda que a precisão de medição do aparelho não seja afetada, deverá adquirir pilhas para a respetiva substituição. Pilhas descarregadas – substituição Quando as pilhas estiverem descarregadas, o símbolo de pilha AM será apresentado a piscar, ao ligar o aparelho (é apresentada uma pilha descarregada). Não é possível efetuar medições e é necessário substituir as pilhas. 1. Abra o compartimento das pilhas 4, situado na parte inferior do aparelho. 2. Substitua as pilhas – verifique a polaridade correta, conforme indicado pelos símbolos existentes no compartimento. 3. Para definir a data e hora, siga o procedimento descrito na «Secção 2.». A memória guarda todos os valores, ainda que a data e hora tenham de ser repostas – deste modo, o número correspondente ao ano é automaticamente apresentado a piscar, quando as pilhas forem substituídas.  Quais as pilhas a utilizar e quais os procedimentos a efetuar? Utilize 4 pilhas alcalinas AA novas, de longa duração, com 1,5 V. Não utilize pilhas cujo prazo de validade tenha sido excedido. Se o aparelho não for utilizado durante um longo período de tempo, deverá retirar as pilhas. Utilizar pilhas recarregáveis Este aparelho também funciona com pilhas recarregáveis. Utilize apenas pilhas recarregáveis do tipo «NiMH»! Caso seja apresentado o símbolo de pilha (pilha descarregada), é necessário substituir e recarregar as pilhas! Não deixe as pilhas no interior do aparelho, uma vez que podem ficar danificadas (pode verificar-se descarga total como resultado de uma utilização pouco frequente do aparelho, mesmo quando desligado). Caso não tencione utilizar o aparelho durante um período igual ou superior a uma semana, retire sempre as pilhas recarregáveis do mesmo! NÃO é possível carregar as pilhas no monitor de pressão arterial! Recarregue este tipo de pilhas utilizando um carregador externo e tenha em atenção as informações respeitantes ao carregamento, cuidados e duração!        8. Utilizar um adaptador Este aparelho pode funcionar com um adaptador da Microlife (DC 6V, 600 mA). Utilize apenas o adaptador da Microlife disponibilizado como acessório original com a voltagem adequada. Certifique-se de que o adaptador e o cabo não se encontram danificados. 1. Ligue o cabo do adaptador à entrada do adaptador 5 no monitor de tensão arterial. 2. Ligue a ficha do adaptador à tomada. Quando o adaptador estiver ligado, não se verifica o consumo da carga das pilhas.   BP A3 Plus 9. Mensagens de erro Se ocorrer um erro durante a medição, esta é interrompida, sendo apresentada uma mensagem de erro, por exemplo, «ERR 3». Erro Descrição Causa possível e solução «ERR 1» Sinal Os sinais da pulsação na braçadeira são demasiado demasiado fracos. Coloque novamente a fraco braçadeira e repita a medição.* «ERR 2» Sinal de Durante a medição, a braçadeira BN erro detectou sinais de erro causados, por exemplo, por movimentos ou pela contração dos músculos. Repita a medição, mantendo o braço imóvel. «ERR 3» Braçadeira Não é possível introduzir pressão suficiente na braçadeira. Poderá ter ocorrido uma BK sem fuga. Verifique se a braçadeira está corretapressão mente ligada e bem ajustada. Substitua as pilhas se necessário. Repita a medição. «ERR 5» ResulOs sinais da medição não são exatos, tados pelo que não é possível apresentar qualimprecisos quer resultado. Consulte a Check-list para efetuar medições corretas e, em seguida, repita a medição.* «HI» Pressão da A pressão da braçadeira é demasiado braçadeira elevada (superior a 299 mmHg) OU a pulsação é demasiado elevada (mais de ou pulsação 200 batimentos por minuto). Descontraia demasiado durante 5 minutos e repita a medição.* elevada «LO» Pulsação A pulsação está demasiado baixa (infedemasiado rior a 40 batimentos por minuto). Repita a baixa medição.* * Por favor, consulte imediatamente o seu médico, se este ou qualquer outro problema ocorrer repetidamente. Se considerar os resultados invulgares, leia cuidadosamente as informações descritas na «Secção 1.».  53 PT 10. Segurança, cuidados, teste de precisão e eliminação de resíduos Segurança e proteção   Siga as instruções de uso. Este documento fornece informações             54 importantes de manuseamento e segurança do produto em relação a este dispositivo. Leia atentamente este documento antes de usar o dispositivo e guarde-o para referência futura. Este dispositivo deve somente ser utilizado para os fins descritos neste folheto. O fabricante não se responsabiliza por quaisquer danos causados pelo uso indevido deste dispositivo. O dispositivo é composto por componentes sensíveis e deve ser manuseado com cuidado. Respeite as indicações de acondicionamento e funcionamento descritas na secção «Especificações técnicas»! Proteja o dispositivo de: - Água e humidade - Temperaturas extremas - Impactos e quedas - Contaminação e poeiras - Luz direta do sol - Calor e frio As braçadeiras são sensíveis e têm de ser manuseadas com cuidado. O dispositivo só pode ser utilizado com braçadeiras ou peças de ligação da Microlife. Encha a braçadeira apenas depois de bem ajustada. Não utilize o dispositivo na proximidade de campos electromagnéticos fortes, tais como, telemóveis ou instalações radiofónicas. Manter uma distância mínima de 3,3 m a partir dos dispositivos mencionados quando se utiliza este dispositivo. Não utilize este dispositivo se estiver danificado ou se detectar qualquer anomalia. Nunca abra o dispositivo. Se o dispositivo não for utilizado durante um longo período de tempo, deverá retirar as pilhas. Consulte também as informações de segurança incluídas nas secções individuais deste manual. O resultado da medição fornecido por este dispositivo não é um diagnóstico. Não substitui a necessidade de consulta com o seu médico, particularmente caso os sintomas do paciente não correspondam ao real. Não confie apenas no resultado da medição, considere sempre outras possibilidades, possíveis sintomas e comentários do paciente. Ligar para o médico ou chamar uma ambulância é aconselhada, caso necessário. Certifique-se de que não deixa o dispositivo ao alcance das crianças, algumas peças são muito pequenas e podem ser engolidas. Esteja atento ao risco de estrangulamento no caso deste dispositivo ser fornecido com cabos ou tubos. Cuidados a ter com o dispositivo Para efetuar a limpeza do dispositivo, utilize apenas um pano macio e seco. Limpeza da braçadeira Limpe a braçadeira cuidadosamente com um pano húmido e espuma de sabão. AVISO: Não lave a braçadeira na máquina de lavar roupa ou loiça!  Teste de precisão Recomendamos a realização de testes de precisão ao dispositivo de 2 em 2 anos ou após impacto mecânico (por exemplo, após uma queda). Contacte o seu local Assistência da Microlife para providenciar o teste (ver mais adiante). Eliminação de resíduos As pilhas e dispositivos eletrónicos têm de ser eliminados em conformidade com os regulamentos locais aplicáveis, uma vez que não são considerados resíduos domésticos. 11. Garantia Este dispositivo está abrangido por uma garantia de 5 anos a partir da data de compra. Durante este momento de garantia, ao seu critério, o reperesentante da Microlife trocará o seu produto defeituoso, sem qualquer custo. A garantia não é válida se o dispositivo for aberto ou alterado. Os seguintes itens estão excluídos da garantia:  Custos de transporte e risco de transporte.  Danos causados por aplicação incorreta ou o não seguimento das instruções de utilização.  Danos causados por vazamento das pilhas.  Danos causados devido a acidente ou má utilização.  Material / armazenamento de embalagem ou instrução de utilização.  Verificações regulares e Manutenção (calibração).  Acessórios e peças: Baterias, adaptador de energia (opcional). A braçadeira tem uma garantia funcional (estanquicidade dabolsa de ar) por 2 anos Se for necessário o uso da garantia, por favor contacte o distribuidor da Marca Microlife. Pode contatar o seu serivço Microlife. Pode contatar o seu serivço Microlife local através do nosso site: www.microlife.com/support Compensação é limitada ao valor do produto. A garantia será limitada se o produto estiver completo e devolvido com a fatura original de compra. Troca dentro do período de garantia não prolonga ou renova o período de garantia. As reinvindicações legais e direitos dos consumidores não são aplicados por esta garantia. Este dispositivo está em conformidade com as exigências da Norma de Dispositivos Médicos 93/42/EEC. O fabricante reserva-se o direito de proceder a alterações técnicas. 12. Especificações técnicas Condições de funcionamento: Condições de acondicionamento: Peso: Dimensões: Procedimento de medição: Gama de medição: Gama de medição da pressão da braçadeira: Resolução: Precisão estática: Precisão da pulsação: Alimentação: 10 - 40 °C / 50 - 104 °F 15 - 95 % de humidade relativa máxima -20 - +55 °C / -4 - +131 °F 15 - 95 % de humidade relativa máxima 368 g (incluindo pilhas) 143 x 85 x 58 mm oscilométrico, correspondente ao método Korotkoff: Fase I sistólica, Fase V diastólica 20 - 280 mmHg – pressão arterial 40 - 200 batimentos por minuto – pulsação 0 - 299 mmHg 1 mmHg pressão dentro de ± 3 mmHg ± 5% do valor obtido Pilhas alcalinas 4 x 1,5 V; tamanho AA Adaptador DC 6 V, 600 mA (opcional) Duração da pilha: aproximadamente 920 medições (usando pilhas novas) Classe IP: IP20 Normas de referência: EN 1060-1 /-3 /-4; IEC 60601-1; IEC 60601-1-2 (EMC); IEC 60601-1-11 Duração expectável Aparelho: 5 anos ou 10000 medições de utilização: Acessórios: 2 anos BP A3 Plus 55 PT Microlife BP A3 Plus 1 2 3 4 5 6 7 8 9 AT AK AAN/UIT knop Display Manchetaansluiting Batterijcompartiment Adapteraansluiting Manchet Manchetconnector MAM Schakelaar Gebruikersschakelaar M-knop (geheugen) Tijdknop Weergave AL Gebruikersindicator AM Batterijweergave AN Datum/tijd AO Systolische waarde AP Diastolische waarde AQ Hartslagfrequentie AR Verkeerslichtweergave indicator AS MAM Intervaltijd BT Hartslag BK Manchetcontrole indicator BL MAM Modus BM Onregelmatige hartslag (IHB) symbool BN Armbeweging indicator BO Opgeslagen waarden Lees alvorens dit apparaat te gebruiken de instructies aandachtig door. Geleverd onderdeel type BF Droog houden 56 NL Het bedoelde gebruik: Deze oscillometrische bloeddrukmonitor is bedoeld voor het noninvasief meten van bloeddruk bij personen van 12 jaar of ouder. Dit apparaat is klinisch gevalideerd voor patiënten met hypertensie, hypotensie, diabetes, zwangerschap, pre-eclampsie, atherosclerose, end-stage renal disease, obesitas en voor ouderen. Geachte klant, Deze bloeddrukmonitor is in samenwerking met artsen ontwikkeld en klinische validatiestudies hebben aangetoond dat de meetnauwkeurigheid bijzonder hoog is.* Mocht u vragen hebben of wanneer u reserveonderdelen wilt bestellen, neemt u dan contact op met uw Microlife importeur. De verkoper zal u het adres van de Microlife importeur in uw land geven. Natuurlijk kunt u ook de website www.microlife.nl raadplegen, waar u waardevolle informatie kunt vinden over onze producten. Blijf gezond – Microlife AG! * Dit apparaat gebruikt o.a. dezelfde meettechnologie als het gevalideerde model «BP 3BTO-A» getest conform het British and Irish Hypertension Society (BIHS) protocol. Inhoudsopgave 1. Belangrijke feiten over bloeddruk en het zelf meten hiervan • Hoe meet ik mijn bloeddruk? 2. Eerste gebruik van het apparaat • Plaatsen van de batterijen • Instellen van datum en tijd • Selecteer de juiste manchet • Selecteren van de gebruiker • Selecteren van de standaardmodus of MAM modus • MAM modus (sterk aanbevolen) 3. Bloeddruk meten • Een meting uitvoeren zonder deze op te slaan 4. Uiterlijk van het symbool voor onregelmatige hartslag (IHB) 5. Verkeerslichtindicatie in de weergave 6. Geheugenopslag • Bekijken van de opgeslagen waarden • Geheugen vol • Wis alle waarden 7. Batterij-indicator en batterijvervanging • Batterijen bijna leeg • Batterijen leeg – vervanging • Welke batterijen en welke werkwijze? • Gebruik van oplaadbare batterijen 8. Gebruik van een netadapter 9. Foutmeldingen 10. Veiligheid, onderhoud, nauwkeurigheidstest en verwijdering • Veiligheid en bescherming • Apparaatonderhoud • Reinig de manchet • Nauwkeurigheidstest • Verwijdering 11. Garantie 12. Technische specificaties Garantiebon (zie achterzijde) BP A3 Plus 1. Belangrijke feiten over bloeddruk en het zelf meten hiervan  Bloeddruk is de druk waarmee het bloed door de aderen stroomt veroorzaakt door het pompen van het hart. Twee waarden, de systolische (boven) waarde en de diastolische (onder) waarde worden altijd gemeten.  Het apparaat geeft ook de hartslagfrequentie (het aantal keren dat het hart per minuut slaat) aan.  Constante hoge bloeddruk kan nadelig zijn voor uw gezondheid en moet door uw arts worden behandeld!  Bespreek altijd uw waarden met uw arts en vertel hem/haar wanneer u iets ongebruikelijks heeft opgemerkt of onzeker bent. Vertrouw nooit op een enkele bloeddrukwaarde.  Er zijn verschillende oorzaken voor hoge bloeddrukwaarden. Uw arts kan de gemeten waarden met u doornemen en indien nodig een behandeling voorstellen. Naast medicatie kan een gezondere levensstijl ook leiden tot verlaging van de bloeddruk (bijv. dieet en meer beweging).  In geen enkel geval zou u de dosering van uw medicatie moeten aanpassen of een behandeling starten zonder een arts te raadplegen.  Afhankelijk van lichamelijke inspanning en conditie, is bloeddruk onderhevig aan brede schommelingen gedurende de dag. U dient daarom de bloeddruk steeds onder dezelfde rustige omstandigheden te meten en wanneer u zich ontspannen voelt! Meet tenminste twee keer 's morgens en twee keer 's avonds en Neem het gemiddelde van alle metingen.  Het is vrij normaal wanneer twee metingen vlak na elkaar genomen opvallend verschillende resultaten opleveren. Daarom bevelen wij de MAM-technologie aan.  Afwijkingen tussen metingen genomen door uw arts of de apotheek en die thuis zijn opgenomen zijn vrij normaal, omdat deze situaties volledig verschillend zijn.  Verschillende metingen geven een veel duidelijker beeld van uw bloeddruk dan slechts één enkele meting. Daarom bevelen wij de MAM-technologie aan.  Neem een korte rustpauze van minimaal 15 seconden tussen twee metingen.  Raadpleeg uw arts voordat u het apparaat gebruikt als u hartritmestoornissen heeft. Zie ook hoofdstuk «Uiterlijk van het symbool voor onregelmatige hartslag (IHB)» van deze gebruikershandleiding. 57 NL  De hartslagfrequentie is niet geschikt voor het controleren van patiënten met een pacemaker!  Indien u zwanger bent adviseren wij u regelmatige uw bloeddruk te meten, omdat uw bloeddruk drastisch kan veranderen gedurende deze periode. Deze meter is speciaal getest voor gebruik tijdens zwangerschap en pre-eclampsie. Wanneer u ongewoon hoge metingen registreert, zou u de meting een tijd later moeten herhalen (bijv. 1 uur). Indien de meting nog steeds te hoog is, raadpleeg dan uw arts of gynaecoloog.  Hoe meet ik mijn bloeddruk? Tabel voor de classificatie van thuis bloeddruk meetwaarden bij volwassenen in overeenstemming met de internationale richtlijnen (ESH, ESC, JSH). Data in mmHg. Bereik 1. bloeddruk normaal 2. bloeddruk optimaal 3. bloeddruk verhoogd 4. bloeddruk te hoog Systolisch < 120 120 - 129 130 - 134 Diastolisch < 74 74 - 79 80 - 84 135 - 159 85 - 99 5. bloeddruk gevaar- ≥ 160 lijk hoog ≥ 100 Advies Zelfcontrole Zelfcontrole Zelfcontrole Win medisch advies in Win dringend medisch advies in! De evaluatie van de waarden zijn conform de tabel. Bijvoorbeeld: een waarde van de bloeddruk van 140/80 mmHg of een waarde van 130/90 mmHg toont «bloeddruk te hoog». 2. Eerste gebruik van het apparaat Plaatsen van de batterijen Nadat u het apparaat heeft uitgepakt, plaatst u eerst de batterijen. Het batterijcompartiment 4 bevindt zich aan de onderzijde van het apparaat. Plaats de batterijen (4 x 1.5 V, grootte AA), let hierbij op de aangegeven polariteit. Instellen van datum en tijd 1. Nadat de batterijen zijn geplaatst knippert het jaartal in het scherm. U kunt het jaar instellen door op de M-knop AT te drukken. Om te bevestigen en vervolgens de maand in te stellen, drukt u op de tijdknop AK. 2. Nu kunt u de maand instellen met de M-knop. Druk op de tijdknop om te bevestigen en stel dan de dag in. 58 3. Volg de bovenstaande instructies om dag, uur en minuten in te stellen. 4. Zodra u de minuten heeft ingesteld en de tijdknop indrukt, zijn de datum en tijd ingesteld en wordt de tijd weergegeven. 5. Als u de datum en de tijd wilt veranderen, houdt u de tijdknop ingedrukt gedurende ca. 3 seconden totdat het jaartal begint te knipperen. Nu kunt u nieuwe waarden invoeren zoals hierboven beschreven. Selecteer de juiste manchet Microlife heeft manchetten in verschillende maten. Selecteer de manchetgrootte die overeenkomt met de omtrek van uw bovenarm (de gemeten omtrek rond het midden van de bovenarm). Manchetgrootte voor omtrek van de bovenarm S 17 - 22 cm M 22 - 32 cm M-L 22 - 42 cm L 32 - 42 cm L - XL 32 - 52 cm Voorgevormde «Easy» manchetten zijn optioneel verkrijgbaar voor een eenvoudige bevestiging en meer comfort. Gebruik alleen Microlife manchetten!  Neem contact op met uw Microlife importeur, als de bijgesloten manchet 6 niet past.  Bevestig de manchet aan het apparaat middels de manchetconnector 7 duw de connector 3 zo ver als mogelijk in het apparaat. Selecteren van de gebruiker Met dit apparaat kunt u de resultaten van 2 gebruikers opslaan.  Stel, vóór elke meting, de gebruikersschakelaar 9 in voor de juiste gebruiker: gebruiker 1 of 2.  Gebruiker 1: schuif de schakelaar 9 omhoog zodat deze bij gebruikersicoon 1 staat.  Gebruiker 2: schuif de schakelaar 9 omlaag zodat deze bij gebruikersicoon 2 staat. De eerste persoon die meet dient gebruiker 1 te selecteren. Selecteren van de standaardmodus of MAM modus Dit apparaat laat u kiezen tussen of standaard (standaard enkelvoudige meting) of modus MAM (automatische drievoudige meting). Om standaard modus te selecteren, schuift u de MAM schakelaar 8 aan de zijkant van het apparaat in stand «1» en om MAM modus te selecteren, schuift u deze schakelaar in stand «3».    MAM modus (sterk aanbevolen)  In MAM modus, 3 metingen worden automatisch genomen in volgorde en het resultaat wordt dan automatisch geanalyseerd en weergegeven. Omdat de bloeddruk constant schommelt, is een op deze manier bepaald resultaat betrouwbaarder dan een die is verkregen door een enkele meting.  Wanneer u de MAM stand selecteert, verschijnt het MAMsymbool BL in het display.  Het gedeelte rechtsonder in het display toont een 1, 2 of 3 om aan te geven welke van de 3 metingen momenteel genomen wordt.  Tussen de metingen wordt een rusttijd van 15 seconden aangehouden. Het aftellen wordt weergegeven in het scherm.  De individuele resultaten worden niet weergegeven. Uw bloeddruk zal alleen worden getoond nadat alle 3 de metingen zijn verricht.  Verwijder de manchet niet tussen de metingen.  Als een van de afzonderlijke metingen twijfelachtig was, dan wordt een vierde automatisch genomen. 3. Bloeddruk meten Stappenplan voor een betrouwbare bloeddrukmeting 1. Vermijd activiteit, eten of roken vlak vóór een meting. 2. Ga zitten op een stoel met rugsteun en ontspan voor 5 minuten. Houd uw voeten naast elkaar op de grond en zit niet met de benen over elkaar. 3. Meet altijd aan dezelfde arm (normaal links). Het wordt aanbevolen dat artsen bij een eerste bezoek van een patiënt beide armen meet om de te meten arm te bepalen. Aan de arm met de hogere bloeddruk moet worden gemeten. 4. Verwijder de kleding die de bovenarm bedekt, mouwen moeten niet worden opgerold om afklemmen te voorkomen. 5. Zorg er altijd voor dat de juiste manchetmaat wordt gebruikt (markering arm omtrek staat vermeld op het manchet).  Bevestig de manchet om de arm, maar niet te strak.  Zorg ervoor dat de manchet 1-2 cm boven uw elleboog is geplaatst.  De artery mark op de manchet (ca. 3 cm lange bar) dient op de ader van de arm (binnenkant) te worden gelegd.  Ondersteun uw arm zodat deze ontspannen is.  Zorg dat de manchet op dezelfde hoogte is als uw hart. 6. Druk op de AAN/UIT knop 1 om de meting te starten. 7. De manchet wordt nu automatisch opgeblazen. Ontspan, beweeg niet en span uw armspieren niet totdat het meetresultaat wordt getoond. Adem normaal en praat niet. BP A3 Plus 8. Wanneer de juiste druk is bereikt, stopt het pompen en daalt de druk langzaam. Als de gewenste druk niet werd bereikt, zal het apparaat automatisch meer lucht in de manchet pompen. 9. Tijdens de meting knippert het hartslag symbool BT op het scherm. 10.Het resultaat, inclusief de systolische AO en de diastolische AP bloeddruk en de hartslagfrequentie AQ wordt weergegeven. Raadpleeg ook deze handleiding voor uitleg van de overige weergaven. 11.Indien de meting klaar is, verwijder de manchet. 12.Schakel het apparaat uit. (De monitor gaat automatisch uit na ongeveer. 1 min.). Een meting uitvoeren zonder deze op te slaan Zodra de meting is uitgevoerd en het resultaat wordt weergegeven in het display houdt u de AAN/UIT knop 1 ingedrukt totdat de «M» BO in het display knippert. Druk dan vervolgens op de M-knop AT, dan wordt de meting verwijderd en niet opgeslagen in het geheugen. U kunt de meting op elk gewenst moment beëindigen door op de AAN/UIT knop te drukken (bijv. wanneer u een ongemakkelijke of een onplezierige druk voelt). Als bekend is dat de systolische bloeddruk heel hoog is, kan het gunstig zijn de druk individueel in te stellen. Druk op de AAN/UIT knop nadat de monitor is opgepompt tot een niveau van ca. 30 mmHg (weergegeven in de display). Hou de knop ingedrukt totdat de druk ca 40 mmHg boven de verwachte waarde – laat dan de knop los.   4. Uiterlijk van het symbool voor onregelmatige hartslag (IHB) Dit symboo BM geeft aan dat er een onregelmatige hartslag is gedetecteerd. In dit geval kan de gemeten bloeddruk afwijken van uw werkelijke bloeddrukwaarden. Het wordt aanbevolen om de meting te herhalen. Informatie voor de arts in geval van het herhaaldelijk verschijnen van het IHB-symbool Dit apparaat is een oscillometrische bloeddrukmeter die ook de pols meet tijdens bloeddrukmeting en aangeeft wanneer de hartslag onregelmatig is. 5. Verkeerslichtindicatie in de weergave De balken aan de linkerkant van het display AR toont de range waarin de gemeten waarden liggen. Afhankelijk van de uitgelezen waarde optimaal (groen), verhoogd (geel), te hoog (oranje) of 59 NL gevaarlijke hoog (rood) geeft het de overeenkomende kleur aan. Deze classificaties zijn gebaseerd op internationale richtlijnen (aan ESH, ESC, JSH), zoals beschreven in «sectie 1.». 6. Geheugenopslag Dit apparaat heeft ruimte voor 99 metingen voor elk van de 2 gebruikers. De metingen worden automatisch opgeslagen. Bekijken van de opgeslagen waarden Selecteer gebruiker 1 of 2 met de gebruikersschakelaar 9. Druk op de M-knop AT, wanneer het apparaat is uitgeschakeld. De weergave toont eerst «M» BO en «A», wat staat voor het gemiddelde van alle opgeslagen waarden. Wederom op de M-knop drukken toont de vorige waarde. Door nogmaals op de M-knop te drukken, kunt u door de meetresultaten heen bladeren. Geheugen vol Let op dat de maximale geheugencapaciteit van 99 metingen per gebruiker niet wordt overschreden. Wanneer de 99 geheugenplaasten vol zijn, wordt de oudste meting automatisch overschreven met de 100e meting. Om gegevensverlies te voorkomen, kunnen de meetwaarden worden geëvalueerd door uw arts voordat de maximale geheugencapaciteit is bereikt. Wis alle waarden Controleer of u de juiste gebruiker heeft geselecteerd. 1. Selecteer gebruiker 1 of 2 met de gebruikersschakelaar 9 als het apparaat uit staat. 2. Houd de M-knop AT ingedrukt totdat «CL» verschijnt en laat de knop dan los. 3. Wanneer «CL» knippert druk dan op de M-knop om alle meetwaarden permanent te verwijderen. Om verwijdering te annuleren druk op de AAN/UIT knop 1 wanneer «CL» knippert. Losse meetwaarden kunnen niet worden gewist.    7. Batterij-indicator en batterijvervanging Batterijen bijna leeg Wanneer de batterijen ongeveer ¾ verbruikt zijn zal het batterijsymbool AM knipperen zodra het apparaat ingeschakeld is (gedeeltelijk geladen batterij wordt weergegeven). Alhoewel het apparaat door zal gaan met betrouwbaar meten moet u batterijen weldra vervangen. 60 Batterijen leeg – vervanging Wanneer de batterijen leeg zijn, zal het batterijsymbool AM knipperen zodra het apparaat ingeschakeld is (lege batterij weergegeven). U kunt niet verder meten en moet de batterijen vervangen. 1. Maak het batterijcompartiment open 4 aan de onderzijde van het apparaat. 2. Vervang de batterijen – controleer de juiste polariteit zoals getoond door de symbolen in het compartiment. 3. Om de datum en de tijd in te stellen volg de procedure zoals beschreven in «Paragraaf 2.». Het geheugen bevat alle waarden alhoewel datum en tijd gereset moeten worden – het jaartal knippert daarom automatisch nadat de batterijen zijn vervangen. Welke batterijen en welke werkwijze? Gebruik 4 nieuwe, long-life 1,5V, type AA alkaline batterijen. Gebruik ge en batterijen waarvan de uiterste verkoopdatum is verstreken. Verwijder de batterijen als het apparaat voor een langere tijd niet gebruikt gaat worden. Gebruik van oplaadbare batterijen U kunt voor dit apparaat ook oplaadbare batterijen gebruiken. Gebruik a.u.b. alleen type «NiMH» oplaadbare batterijen! De batterijen moeten worden verwijderd en opgeladen, als het batterijsymbool (batterij leeg) verschijnt! Ze moeten niet in het apparaat blijven, omdat ze beschadigd kunnen raken (volledige ontlading tengevolge van een minimaal gebruik van het apparaat, zelfs wanneer het uitstaat). Verwijder altijd de oplaadbare batterijen, als u niet van plan bent het apparaat voor een week of langer te gebruiken! De batterijen kunnen NIET worden opgeladen in de bloeddrukmonitor! Laad deze batterijen op in een externe oplader en houdt u aan de informatie met betrekking tot het opladen, onderhoud en duurzaamheid!         8. Gebruik van een netadapter U kunt dit apparaat met de Microlife netadapter (DC 6V, 600 mA) gebruiken. Gebruik alleen de origineel beschikbare Microlife netadapter voor uw voedingsspanning. Controleer dat zowel de netadapter als de kabel niet beschadigd zijn. 1. Steek de adapter kabel in de netadapteraansluiting 5 van de bloeddrukmonitor.   2. Steek de netadapterstekker in de wandcontactdoos. Wanneer de netadapter is aangesloten, wordt er geen batterijstroom gebruikt. 9. Foutmeldingen Als er een fout optreedt, wordt de meting onderbroken en wordt een foutmelding, b.v. «ERR 3», weergegeven. Fout Beschrijving Mogelijke oorzaak en oplossing «ERR 1» Signaal te De polsslag wordt onvoldoende doorgezwak geven door de manchet. Plaats de manchet opnieuw en herhaal de meting.* «ERR 2» Foutmelding Tijdens het meten zijn er fouten ontstaan, BN door bijvoorbeeld een beweging of samentrekking van een spier. Herhaal de meting terwijl u uw arm stil houdt. «ERR 3» Geen juiste Een adequate druk kan niet in de BK drukopbouw manchet worden geproduceerd. Er kan in de een lek in het manchet zijn. Controleer of manchet de manchet goed is aangesloten en niet te los om de arm zit. Vervang de batterijen indien nodig. Herhaal de meting. «ERR 5» Abnormaal De meetsignalen zijn onbetrouwbaar en resultaat daarom kan geen resultaat worden weergegeven. Neem het stappenplan door voor een betrouwbare meting en herhaal dan de metingen. «ERR 6» MAM Modus Er waren teveel fouten tijdens het meten in MAM mode, wat het onmogelijk maakt om een betrouwbaar resultaat weer te geven. Lees de controlelijst door voordat u betrouwbare metingen verricht en herhaal dan de metingen. «HI» Hartslag of De druk in de manchet is te hoog manchet(boven 299 mmHg) OF de hartslagfredruk te hoog quentie is te hoog (boven 200 slagen per minuut). Ontspan gedurende 5 minuten en herhaal de meting.* «LO» Polsslag te De hartslagfrequentie is te laag (minder laag dan 40 slagen per minuut). Herhaal de meting.* * Neem a.u.b. onmiddelijk contact op met uw arts wanneer dit of enig ander probleem vaker optreedt. BP A3 Plus  Als u denkt dat de resultaten ongebruikelijk zijn, leest u dan a.u.b. zorgvuldig de informatie in «Paragraaf 1.». 10. Veiligheid, onderhoud, nauwkeurigheidstest en verwijdering  Veiligheid en bescherming  Volg de instructies voor correct gebruik. Deze documentatie voorziet u van belangrijke bedienings- en veiligheidsvoorschriften betreffende dit apparaat. Lees de documentatie zorgvuldig door vóór ingebruikname van het apparaat en bewaar het voor latere raadpleging.  Dit apparaat mag uitsluitend worden gebruikt voor het doel zoals in de gebruiksaanwijzing beschreven. De fabrikant kan niet aansprakelijk worden gesteld voor schade veroorzaakt door onjuist gebruik.  Dit apparaat bevat gevoelige componenten en moet met voorzichtigheid worden behandeld. Neem de bewaar- en bedieningsvoorschriften in acht beschreven in het hoofdstuk «Technische specificaties»!  Bescherm het tegen: - water en vochtigheid - extreme temperaturen - schokken en laten vallen - vervuiling en stof - direct zonlicht - warmte en kou  De manchet is kwetsbaar en moet met zorgvuldigheid worden behandeld.  Gebruik geen andere manchetten en/of manchetconnectors dan geleverd bij het apparaat.  Alleen de manchet oppompen wanneer het aan de arm is aangebracht.  Gebruik het apparaat niet dicht in de buurt van sterke elektromagnetische velden zoals mobiele telefoons of radioinstallaties. Zorg voor een afstand van minimaal 3,3 meter van dit soort apparaten, wanneer u dit apparaat in gebruik neemt.  Gebruik het apparaat niet wanneer u vermoedt dat het beschadigd is of wanneer u tijdens het gebruik iets ongebruikelijks constateert.  Open het apparaat nooit.  Wanneer het apparaat voor een langere tijd niet gebruikt gaat worden moeten de batterijen worden verwijderd. 61 NL  Lees de verdere veiligheidsinstructies in de afzonderlijke paragrafen van dit boekje.  De gemeten resultaten met dit apparaat stellen geen diagnose. Het vervangt geen conslutatie van een arts, zeker niet wanneer symptomen niet overeenkomen. Vertouw niet enkel op het meetresultaat, neem altijd de overige symptomen in beschouwing, evenals de terugkoppling van de patient. Bij twijfel altijd contact opnemen met uw arts. Laat kinderen het apparaat alleen onder toezicht van een volwassene gebruiken. Kleine onderdelen kunnen worden ingeslikt. Wees alert op het gevaar van verstrengeling, indien het apparaat is voorzien van kabels of slangen. Apparaatonderhoud Reinig het apparaat alleen met een zachte droge doek. Reinig de manchet Verwijder vlekken op de manchet met een vochtige doek en een mild reinigingsmiddel. WAARSCHUWING: Was de manchet nooit in de wasmachine en/of afwasmachine!  Nauwkeurigheidstest Wij adviseren om dit apparaat elke 2 jaar op nauwkeurigheid te laten testen of na mechanische schok (bijv. na een val). Neem a.u.b. contact op met uw Microlife importeur om een algemene functiecontrole aan te vragen (zie voorwoord). Verwijdering Batterijen en elektronische instrumenten moeten volgens de plaatselijke regelgeving worden verwijderd, niet bij het huishoudelijke afval. 11. Garantie Dit apparaat heeft een garantie van 5 jaar vanaf aankoopdatum. Tijdens deze garantieperiode zal Microlife het defecte product gratis repareren of vervangen. Opening van of wijzigingen aan het apparaat maken de garantie ongeldig. De volgende items zijn uitgesloten van garantie:  Transportkosten en transportrisico's.  Schade veroorzaakt door onjuist gebruik of niet-naleving van de gebruiksaanwijzing.  Schade veroorzaakt door lekkende batterijen.  Schade veroorzaakt door vallen of verkeerd gebruik. 62  Verpakkings- / opslagmateriaal en gebruiksaanwijzing.  Regelmatige controles en onderhoud (kalibratie).  Accessoires en verbruiksmaterialen: Batterijen, voedingsadapter (optioneel). De manchet is gedekt door een functionele garantie (strakheid van de blaas) gedurende 2 jaar. Als garantie nodig is, neem dan contact op met de dealer waar u het product hebt gekocht, of met uw lokale Microlife service. Ukan via onze website contact opnemen met uw lokale Microlife dealer: www.microlife.com/support De vergoeding is beperkt tot de waarde van het product. De garantie wordt verleend als het volledige product wordt geretourneerd met de originele factuur. Reparatie of vervanging binnen de garantie verlengt of verlengt de garantieperiode niet. De wettelijke claims en rechten van consumenten zijn nietbeperkt door deze garantie. 12. Technische specificaties Werkings10 - 40 °C / 50 - 104 °F condities: 15 - 95 % maximale relatieve vochtigheid Bewaarcondities: -20 - +55 °C / -4 - +131 °F 15 - 95 % maximale relatieve vochtigheid Gewicht: 368 g (inclusief batterijen) Afmetingen: 143 x 85 x 58 mm oscillometrisch, volgens de Korotkoff Meetprocedure: methode: Fase I systolisch Fase V diastolisch Meetbereik: 20 - 280 mmHg – bloeddruk 40 - 200 slagen per minuut – polsslag Manchetdruk weergave bereik: 0 - 299 mmHg Resolutie: 1 mmHg Statische nauwkeurigheid: druk binnen ± 3 mmHg Hartslagnauwkeurigheid: ±5 % van de weergegeven waarde Spanningsbron: 4 x 1,5V alkaline batterijen; type AA Netadapter DC 6V, 600 mA (optioneel) Levensduur batterij: ongeveer 920 metingen (met nieuwe batterijen) IP Klasse: IP20 Verwijzing naar normen: Verwachte levensduur: EN 1060-1 /-3 /-4; IEC 60601-1; IEC 60601-1-2 (EMC); IEC 60601-1-11 Apparaat: 5 jaar of 10000 metingen Accessoires: 2 jaar Dit apparaat komt overeen met de normen van de richtlijn medische hulpmiddelen 93/42/EEC. Technische wijzigingen voorbehouden. BP A3 Plus 63 NL Microlife BP A3 Plus 1 2 3 4 5 6 7 8 9 AT AK Πλήκτρο ON/OFF Οθόνη Υποδοχή περιχειρίδας Θήκη μπαταριών Υποδοχή μετασχηματιστή ρεύματος Περιχειρίδα Βύσμα περιχειρίδας Διακόπτης MAM Διακόπτης χρήστη Πλήκτρο M (Μνήμη) Πλήκτρο χρόνου Οθόνη AL Δείκτης χρήστη AM Ένδειξη μπαταρίας AN Ημερομηνία/ώρα AO Τιμή συστολικής πίεσης AP Τιμή διαστολικής πίεσης AQ Σφύξεις AR Ένδειξη χρωματικής διαβάθμισης AS Ώρα μεσοδιαστήματος MAM BT Ένδειξη παλμών BK Ένδειξη ελέγχου περιχειρίδας BL Λειτουργία MAM BM Σύμβολο ακανόνιστου καρδιακού παλμού (IHB) BN Ένδειξη κίνησης βραχίονα BO Αποθηκευμένη τιμή Διαβάστε προσεκτικά τις οδηγίες πριν χρησιμοποιήσετε αυτή τη συσκευή. Τύπος BF εφαρμοσμένο τμήμα Κρατήστε το στεγνό 64 GR Προβλεπόμενη χρήση: Αυτό το παλμογραφικό πιεσόμετρο προορίζεται για τη μη επεμβατική μέτρηση της πίεσης αίματος σε άτομα ηλικίας 12 ετών και άνω. Είναι κλινικά εγκεκριμένο σε ασθενείς με υπέρταση, υπόταση, διαβήτη, εγκυμοσύνη, προ-εκλαμψία, αρτηριοσκλήρωση, νεφροπάθεια τελικού σταδίου, παχυσαρκία και στους ηλικιωμένους. Αγαπητέ πελάτη, Το όργανο αυτό σχεδιάστηκε σε συνεργασία με ιατρούς, ενώ σύμφωνα με κλινικές δοκιμές αποδεικνύεται ότι η ακρίβεια μέτρησής του είναι ιδιαίτερα υψηλή.* Εάν έχετε οποιεσδήποτε απορίες ή προβλήματα ή εάν θέλετε να παραγγείλετε κάποιο ανταλλακτικό εξάρτημα, απευθυνθείτε στο τοπικό σας τμήμα εξυπηρέτησης πελατών της Microlife. Ο πωλητής σας ή το φαρμακείο της περιοχής σας θα σας ενημερώσουν σχετικά με την διεύθυνση του αντιπροσώπου Microlife στην χώρα σας. Εναλλακτικά, επισκεφθείτε την ιστοσελίδα μας στο διαδίκτυο στη διεύθυνση www.microlife.com, όπου μπορείτε να βρείτε πολλές χρήσιμες πληροφορίες σχετικά με τα προϊόντα μας. Μείνετε υγιείς – Microlife AG! * Το όργανο αυτό χρησιμοποιεί την ίδια τεχνολογία μετρήσεων με το βραβευμένο μοντέλο «BP 3BTO-A», το οποίο έχει ελεγχθεί σύμφωνα το πρωτόκολλο της Βρετανικής Εταιρείας Υπέρτασης (BIHS). Πίνακας περιεχομένων 1. Σημαντικές πληροφορίες σχετικά με την αρτηριακή πίεση και την αυτομέτρηση • Πώς να αξιολογήσω την αρτηριακή μου πίεση; 2. Χρήση της συσκευής για πρώτη φορά • Τοποθέτηση των μπαταριών • Ρύθμιση ημερομηνίας και χρόνου • Επιλέξτε τη σωστή περιχειρίδα • Επιλέξτε τον χρήστη • Επιλέξτε τη λειτουργία μέτρησης: τυπική ή MAM • Λειτουργία MAM (συνιστάται ιδιαίτερα) 3. Μέτρηση της αρτηριακής πίεσης • Πώς να μην αποθηκεύσετε μια μέτρηση 4. Εμφάνιση του συμβόλου ακανόνιστου καρδιακού παλμού (IHB) 5. Ένδειξη χρωματικής διαβάθμισης στην οθόνη 6. Μνήμη δεδομένων • Εμφάνιση των αποθηκευμένων τιμών • Μνήμη πλήρης • Διαγραφή όλων των τιμών 7. Ένδειξη μπαταρίας και αντικατάσταση μπαταριών • Μπαταρίες σχεδόν αποφορτισμένες • Μπαταρίες αποφορτισμένες – αντικατάσταση • Ποιες μπαταρίες και ποια διαδικασία • Χρήση επαναφορτιζόμενων μπαταριών 8. Χρήση μετασχηματιστή ρεύματος 9. Μηνύματα σφάλματος 10. Ασφάλεια, φροντίδα, έλεγχος ακρίβειας και απόρριψη • Ασφάλεια και προστασία • Φροντίδα του πιεσόμετρου • Καθαρισμός της περιχειρίδας • Έλεγχος ακρίβειας • Απόρριψη 11. Εγγύηση 12. Τεχνικά χαρακτηριστικά Κάρτα εγγύησης (βλ. οπισθόφυλλο) BP A3 Plus 1. Σημαντικές πληροφορίες σχετικά με την αρτηριακή πίεση και την αυτομέτρηση  Η αρτηριακή πίεση είναι η πίεση του αίματος που ρέει μέσω των αρτηριών, η οποία δημιουργείται από την άντληση της καρδιάς. Πάντοτε μετρώνται δύο τιμές, η συστολική (επάνω) τιμή και η διαστολική (κάτω) τιμή.  Το όργανο εμφανίζει επίσης τις σφύξεις (πόσες φορές η καρδιά πάλλεται σε ένα λεπτό).  Η σταθερά υψηλή πίεση μπορεί να προκαλέσει βλάβη στην υγεία και πρέπει να αντιμετωπιστεί από τον ιατρό σας!  Στον ιατρό σας πρέπει να αναφέρετε πάντοτε τις τιμές πίεσής σας, εάν έχετε παρατηρήσει κάτι μη φυσιολογικό ή εάν δεν είστε σίγουροι. Ποτέ μη βασίζεστε μόνο στις μετρήσεις της αρτηριακής πίεσης.  Υπάρχουν πολλές αιτίες υπερβολικά υψηλής αρτηριακής πίεσης. Ο ιατρός σας θα σας εξηγήσει τις αιτίες αυτές με περισσότερες λεπτομέρειες και θα σας χορηγήσει αγωγή ανάλογα με την περίπτωση. Εκτός της φαρμακευτικής αγωγής, η απώλεια βάρους και η άσκηση μπορούν επίσης να ελαττώσουν την πίεση σας.  Σε καμία περίπτωση δεν πρέπει να αλλάξετε τη δοσολογία των φαρμάκων ή να ξεκινήσετε μια θεραπεία χωρίς να συμβουλευτείτε το γιατρό σας.  Ανάλογα με τη σωματική καταπόνηση και τη φυσική σας κατάσταση, η αρτηριακή πίεση κυμαίνεται σημαντικά στη διάρκεια της ημέρας. Για το λόγο αυτό, πρέπει να μετράτε την πίεσή σας στις ίδιες συνθήκες ηρεμίας και όταν αισθάνεστε ότι έχετε χαλαρώσει! Κάνετε τουλάχιστον δυο μετρήσεις κάθε φορά (το πρωί και το βράδυ) και πάρετε τον μέσο όρο των μετρήσεων.  Είναι αρκετά σύνηθες δύο διαδοχικές μετρήσεις να δίνουν σημαντικά διαφορετικές τιμές. Ως εκ τούτου συνιστούμε την χρήση τεχνολογίας MAM.  Οι αποκλίσεις μεταξύ των μετρήσεων από τον ιατρό σας ή το φαρμακείο και των μετρήσεων στο σπίτι είναι αρκετά φυσιολογικές, διότι οι συνθήκες είναι εντελώς διαφορετικές.  Πολλές μετρήσεις παρέχουν πολύ περισσότερο αξιόπιστες πληροφορίες σχετικά με την πίεση σας, από μια μεμονωμένη μέτρηση. Ως εκ τούτου συνιστούμε την χρήση τεχνολογίας MAM.  Αφήστε ένα μικρό χρονικό περιθώριο τουλάχιστον 15 δευτερολέπτων μεταξύ δύο μετρήσεων.  Εάν υποφέρετε από καρδιακή αρρυθμία, συμβουλευτείτε το γιατρό σας πριν χρησιμοποιήσετε τη συσκευή. Ανατρέξτε 65 GR επίσης στο κεφάλαιο «Εμφάνιση του συμβόλου ακανόνιστου καρδιακού παλμού (IHB)» αυτού του εγχειριδίου χρήσης.  Η ένδειξη παλμού δεν είναι κατάλληλη για τον έλεγχο της συχνότητας του βηματοδότη!  Εάν είστε έγκυος, πρέπει να παρακολουθείτε την αρτηριακή σας πίεση τακτικά διότι μπορεί να ποικίλει σημαντικά στην περίοδο της κύησης. Αυτή η συσκευή είναι ειδικά ελεγμένη για χρήση κατά την εγκυμοσύνη και την προεκλαμψία. Όταν εντοπίζετε ασυνήθιστα υψηλές τιμές μετρήσεων στην εγκυμοσύνη, θα πρέπει να επαναλάβετε μετά από λίγο τη μέτρηση (π.χ. σε 1 ώρα) Εάν το αποτέλεσμα είναι ακόμα πολύ υψηλό, συμβουλευτείτε το γιατρό ή τον γυναικολόγο σας.  Πώς να αξιολογήσω την αρτηριακή μου πίεση; Πίνακας για την ταξινόμηση τιμών μέτρησης πίεσης του αίματος στο σπίτι, σε ενήλικες, σύμφωνα με τις διεθνείς οδηγίες (ESH, ESC, JSH). Τα δεδομένα σε mmHg. Εύρος τιμών 1. αρτηριακή πίεση φυσιολογική 2. αρτηριακή πίεση βέλτιστη 3. αρτηριακή πίεση αυξημένη 4. αρτηριακή πίεση πολύ υψηλή 5. αρτηριακή πίεση επικίνδυνα υψηλή Συστολική < 120 Διαστολική Σύσταση < 74 Αυτοέλεγχος 120 - 129 74 - 79 Αυτοέλεγχος 130 - 134 80 - 84 Αυτοέλεγχος 135 - 159 85 - 99 ≥ 160 ≥ 100 Ζητήστε ιατρική συμβουλή Ζητήστε επειγόντως ιατρική συμβουλή! Η υψηλότερη τιμή είναι αυτή βάσει της οποίας καθορίζεται η αξιολόγηση. Παράδειγμα: τιμή πίεσης 140/80 mmHg ή τιμή 130/90 mmHg υποδεικνύει «πολύ υψηλή πίεση». 2. Χρήση της συσκευής για πρώτη φορά Τοποθέτηση των μπαταριών Αφού αποσυσκευάσετε τη συσκευή, τοποθετήστε πρώτα τις μπαταρίες. Η θήκη της μπαταριών 4 βρίσκεται στο κάτω μέρος της συσκευής. Εισάγετε τις μπαταρίες (4 x 1,5 V μπαταρίες, μεγέθους AA) προσέχοντας την ενδεικνυόμενη πολικότητα. 66 Ρύθμιση ημερομηνίας και χρόνου 1. Μετά την τοποθέτηση των καινούργιων μπαταριών, στην οθόνη αναβοσβήνει ο αριθμός του έτους. Μπορείτε να ρυθμίσετε το έτος πατώντας το πλήκτρο M AT. Για επιβεβαίωση και στη συνέχεια για να ρυθμίσετε το μήνα, πατήστε το πλήκτρο χρόνου AK. 2. Τώρα μπορείτε να ρυθμίσετε το μήνα πατώντας το πλήκτρο M. Πατήστε το πλήκτρο χρόνου για επιβεβαίωση και στη συνέχεια ρυθμίστε την ημέρα. 3. Ακολουθήστε τις παραπάνω οδηγίες για να ρυθμίσετε την ημέρα, την ώρα και τα λεπτά. 4. Μόλις ρυθμίσετε τα λεπτά και πατήσετε το πλήκτρο χρόνου, ρυθμίζεται η ημερομηνία και η ώρα και εμφανίζεται η ώρα. 5. Εάν θέλετε να αλλάξετε την ημερομηνία και την ώρα, πατήστε και κρατήστε πατημένο το πλήκτρο επί 3 δευτ. περίπου μέχρις ότου αρχίσει να αναβοσβήνει ο αριθμός του έτους. Τώρα μπορείτε να εισάγετε τις νέες τιμές όπως περιγράφεται παραπάνω. Επιλέξτε τη σωστή περιχειρίδα Η Microlife προσφέρει διάφορα μεγέθη περιχειρίδων. Επιλέξτε το μέγεθος περιχειρίδας που ταιριάζει στην περίμετρο του μπράτσου σας (μετράται εφαρμοστά στο κέντρο του μπράτσου). Μέγεθος περιχειρίδας για την περίμετρο του μπράτσου S 17 - 22 cm M 22 - 32 cm M-L 22 - 42 cm L 32 - 42 cm L - XL 32 - 52 cm Προαιρετικές προ-φορμαρισμένες περιχειρίδες «Easy» είναι διαθέσιμες για καλύτερη εφαρμογή και άνεση. Χρησιμοποιείτε μόνο περιχειρίδες Microlife!  Επικοινωνήστε με το τοπικό σας τμήμα εξυπηρέτησης πελατών της Microlife εάν η συνοδευτική περιχειρίδα 6 δεν ταιριάζει.  Συνδέστε την περιχειρίδα στο όργανο τοποθετώντας το βύσμα της περιχειρίδας 7 στην υποδοχή της περιχειρίδας 3 όσο το δυνατόν πιο μέσα.   Επιλέξτε τον χρήστη Αυτή η συσκευή επιτρέπει την αποθήκευση αποτελεσμάτων για 2 μεμονωμένους χρήστες.  Πριν κάθε μέτρηση, ρυθμίστε τον διακόπτη χρήστη για τον προβλεπόμενο χρήστη 9: Χρήστης 1 ή χρήστης 2.   Χρήστης 1: Σύρετε το διακόπτη του χρήστη 9 προς τα επάνω στο εικονίδιο του χρήστη 1. Χρήστης 2: Σύρετε το διακόπτη του χρήστη 9 προς τα κάτω στο εικονίδιο του χρήστη 2. Το πρώτο άτομο που θα μετρηθεί θα πρέπει να επιλέξει τον χρήστη 1.  Επιλέξτε τη λειτουργία μέτρησης: τυπική ή MAM Αυτό το όργανο σάς δίνει τη δυνατότητα να επιλέξετε είτε την τυπική λειτουργία (τυπική μονή μέτρηση) είτε τη λειτουργία MAM (αυτόματη τριπλή μέτρηση). Για να επιλέξετε την τυπική λειτουργία, μετακινήστε το διακόπτη MAM 8 που βρίσκεται στο πλάι του οργάνου προς τα κάτω στη θέση «1», και για να επιλέξετε τη λειτουργία MAM, μετακινήστε το διακόπτη προς τα πάνω στη θέση «3». Λειτουργία MAM (συνιστάται ιδιαίτερα)  Στη λειτουργία MAM, πραγματοποιούνται αυτόματα 3 μετρήσεις διαδοχικά και το αποτέλεσμα αναλύεται αυτόματα και εμφανίζεται στην οθόνη. Επειδή η αρτηριακή πίεση μεταβάλλεται διαρκώς, το αποτέλεσμα που μετράται με αυτό τον τρόπο είναι πιο αξιόπιστο από αυτό που βασίζεται σε μία μόνο μέτρηση.  Όταν διαλέγετε την μέθοδο 3 μετρήσεων, το σύμβολο MAM BL εμφανίζεται στην οθόνη.  Στο κάτω δεξί μέρος της οθόνης εμφανίζεται ο αριθμός 1, 2 ή 3, ανάλογα ποια από τις 3 μετρήσεις πραγματοποιείται τη συγκεκριμένη στιγμή.  Υπάρχει ένα διάλειμμα 15 δευτερολέπτων μεταξύ των μετρήσεων. Μια αντίστροφη μέτρηση υποδεικνύει τον υπολειπόμενο χρόνο.  Τα αποτελέσματα κάθε μέτρησης δεν εμφανίζονται ξεχωριστά. Η αρτηριακή σας πίεση εμφανίζεται μόνο αφού ολοκληρωθούν και οι 3 μετρήσεις.  Μην αφαιρείτε την περιχειρίδα μεταξύ των μετρήσεων.  Εάν μία από τις τρεις μετρήσεις ήταν αμφισβητήσιμη, πραγματοποιείται αυτόματα μια τέταρτη μέτρηση. 3. Μέτρηση της αρτηριακής πίεσης Λίστα ελέγχων για την πραγματοποίηση αξιόπιστης μέτρησης 1. Αποφύγετε τη σωματική δραστηριότητα, την κατανάλωση φαγητού ή το κάπνισμα αμέσως πριν από τη μέτρηση. BP A3 Plus 2. Καθίστε σε καρέκλα με πλάτη και χαλαρώστε για 5 λεπτά. Πατήστε τα πόδια σταθερά στο πάτωμα και μην τα σταυρώνετε. 3. Η μέτρηση πρέπει να γίνεται πάντοτε στο ίδιο χέρι (συνήθως το αριστερό). Συνιστάται στους γιατρούς κατά την πρώτη επίσκεψη ενός ασθενούς, να πραγματοποιούν μέτρηση και στους δυο βραχίονες, προκειμένου να καθορίσουν ποιόν βραχίονα θα μετρούν στο μέλλον. Πρέπει να μετρούν τον βραχίονα με την υψηλότερη πίεση. 4. Αφαιρέστε τα εφαρμοστά ρούχα από το μπράτσο. Για να αποφύγετε την περίσφιξη, το μανίκι του πουκάμισου δεν πρέπει να είναι γυρισμένο προς τα πάνω - δεν παρεμποδίζει την περιχειρίδα εάν είναι κατεβασμένο. 5. Πάντα να βεβαιώνεστε ότι χρησιμοποιείτε το σωστό μέγεθος περιχειρίδας (αναφέρεται στην περιχειρίδα).  Τοποθετήστε την περιχειρίδα εφαρμοστά, αλλά όχι πολύ σφικτά.  Βεβαιωθείτε ότι η περιχειρίδα τοποθετείται 1-2 εκατοστά πάνω από τον αγκώνα σας.  Η ένδειξη αρτηρία που βρίσκεται στην περιχειρίδα (περίπου 3 εκατοστά) πρέπει να βρίσκεται πάνω από την αρτηρία η οποία διατρέχει το εσωτερικό μέρος του βραχίονα.  Στηρίξτε τον πήχη του χεριού σας ώστε το χέρι σας να είναι χαλαρό.  Βεβαιωθείτε ότι η περιχειρίδα βρίσκεται στο ίδιο ύψος με την καρδιά σας. 6. Πατήστε το πλήκτρο ON/OFF 1 για να αρχίσει η μέτρηση. 7. Η περιχειρίδα θα φουσκώσει αυτόματα. Χαλαρώστε, μην κινήστε και μη σφίγγετε τους μύες του χεριού σας μέχρι να εμφανιστεί η τιμή της μέτρησης. Αναπνέετε φυσιολογικά και μη μιλάτε. 8. Όταν επιτευχθεί η σωστή πίεση, το φούσκωμα σταματά και η πίεση μειώνεται σταδιακά. Εάν η σωστή πίεση δεν επιτευχθεί, το όργανο θα διοχετεύσει αυτόματα περισσότερο αέρα μέσα στην περιχειρίδα. 9. Κατά τη μέτρηση, η ένδειξη παλμού BT αναβοσβήνει στην οθόνη. 10.Εμφανίζεται το αποτέλεσμα, το οποίο περιλαμβάνει αρτηριακή πίεση συστολική AO, διαστολική AP και την συχνότητα των παλμών AQ. Δείτε επίσης τις επεξηγήσεις των υπόλοιπων ενδείξεων στο παρόν φυλλάδιο. 11.Όταν η μέτρηση ολοκληρωθεί, αφαιρέστε την περιχειρίδα. 12.Aπενεργοποιήστε το όργανο. (Η οθόνη σβήνει αυτόματα μετά από 1 λεπτό περίπου) 67 GR Πώς να μην αποθηκεύσετε μια μέτρηση Μόλις εμφανιστεί η μέτρηση πιέστε και κρατήστε το πλήκτρο ON/ OFF 1 έως ότου το σύμβολο «M» BO αρχίσει να αναβοσβήνει. Επιβεβαιώστε την διαγραφή της μέτρησης πιέζοντας το πλήκτρο M AT. Μπορείτε να σταματήσετε τη μέτρηση οποιαδήποτε στιγμή εάν πατήσετε το πλήκτρο ON/OFF (π.χ. εάν δεν αισθάνεστε άνετα ή εάν νιώθετε μια δυσάρεστη αίσθηση πίεσης). Εάν υπάρχει ιστορικό υψηλής συστολικής πίεσης, μπορεί να είναι ωφέλιμη η μεμονωμένη ρύθμιση της πίεσης. Πατήστε το πλήκτρο ON/OFF όταν η ένδειξη ανέλθει στα 30 mmHg περίπου (απεικονίζεται στην οθόνη). Κρατήστε το πλήκτρο πατημένο μέχρι η πίεση να φτάσει περίπου στα 40 mmHg πάνω από την αναμενόμενη συστολική τιμή – στη συνέχεια αφήστε το πλήκτρο.   4. Εμφάνιση του συμβόλου ακανόνιστου καρδιακού παλμού (IHB) Αυτό το σύμβολο BM υποδεικνύει ότι ανιχνεύθηκε ακανόνιστος καρδιακός παλμός. Σε αυτή την περίπτωση, η μετρηθείσα αρτηριακή πίεση μπορεί να αποκλίνει από τις πραγματικές τιμές πίεσης του αίματος. Συνιστάται η επανάληψη της μέτρησης. Πληροφορίες για τον γιατρό σε περίπτωση επανειλημμένης εμφάνισης του συμβόλου IHB Αυτή η συσκευή είναι ένα παλμογραφικό πιεσόμετρο που μετρά επίσης τον παλμό κατά τη διάρκεια της μέτρησης της πίεσης του αίματος και υποδεικνύει πότε ο καρδιακός ρυθμός είναι ακανόνιστος. 5. Ένδειξη χρωματικής διαβάθμισης στην οθόνη Οι μπάρες στο αριστερό άκρο της οθόνης AR σας δείχνουν το εύρος εντός του οποίου κυμαίνεται η ενδεικνυόμενη τιμή της αρτηριακής πίεσης. Ανάλογα με το ύψος της ράβδου, η καταγραμμένη τιμή βρίσκεται εντός του βέλτιστου (πράσινο), αυξημένου (κίτρινο), πολύ υψηλού (πορτοκαλί) ή επικίνδυνα υψηλού (κόκκινο) φάσματος. Η κατάταξη αντιστοιχεί στις 4 σειρές του πίνακα, όπως ορίζεται από τις διεθνείς οδηγίες (ESH, ESC, JSH), όπως περιγράφεται στο «Ενότητα 1.». 68 6. Μνήμη δεδομένων Η συσκευή αποθηκεύει αυτόματα πάνω από 99 μετρήσεις για καθένα από τους 2 χρήστες. Εμφάνιση των αποθηκευμένων τιμών Επιλέξτε είτε τον χρήστη 1 ή 2 με το πλήκτρο χρήστη 9. Πατήστε το πλήκτρο M AT στιγμιαία, όταν το όργανο είναι απενεργοποιημένο. Αρχικά επιδεικνύεται στην οθόνη το σύμβολο «M» BO και «A», το οποίο αντιπροσωπεύει τον μέσο όρο όλων των αποθηκευμένων μετρήσεων. Εάν πατήσετε ξανά το πλήκτρο Μ, στην οθόνη εμφανίζεται η προηγούμενη τιμή. Εάν πατήσετε ξανά το πλήκτρο Μ επανειλημμένα, έχετε τη δυνατότητα μετάβασης από τη μία αποθηκευμένη τιμή στην άλλη. Μνήμη πλήρης Προσέξτε να μην υπερβείτε την μέγιστη δυνατότητα αποθήκευσης των 99 μετρήσεων ανά χρήστη. Όταν η μνήμη 99 μετρήσεων είναι πλήρης, η παλαιότερη τιμή καλύπτεται αυτόματα από την 100η τιμή μέτρησης. Οι μετρήσεις θα πρέπει να εκτιμηθούν από τον γιατρό σας προτού γεμίσει η χωρητικότητα μνήμης – αλλιώς τα στοιχεία θα χαθούν. Διαγραφή όλων των τιμών Βεβαιωθείτε ότι έχει ενεργοποιηθεί ο σωστός χρήστης. 1. Επιλέξτε χρήστη 1 ή χρήστη 2 με τον διακόπτη χρήστη 9, όταν η συσκευή είναι κλειστή. 2. Κρατήστε πατημένο το πλήκτρο Μ AT μέχρι το σύμβολο «CL» να εμφανιστεί και μετά ελευθερώστε το πλήκτρο. 3. Κρατήστε πατημένο το πλήκτρο Μ για όσο το σύμβολο «CL» αναβοσβήνει και διαγράφει μόνιμα όλες τις μετρήσεις του επιλεγμένου χρήστη. Ακυρώστε την διαγραφή: Πιέστε το πλήκτρο ON/OFF 1 όσο το σύμβολο «CL» αναβοσβήνει. Οι μεμονωμένες τιμές δεν μπορούν να διαγραφούν.    7. Ένδειξη μπαταρίας και αντικατάσταση μπαταριών Μπαταρίες σχεδόν αποφορτισμένες Όταν οι μπαταρίες έχουν αποφορτιστεί κατά τα ¾ περίπου, το σύμβολο της μπαταρίας AM αναβοσβήνει μόλις το όργανο ενεργοποιείται (εμφανίζεται μια μπαταρία φορτισμένη κατά το ήμισυ). Παρ' ότι το όργανο συνεχίζει να μετρά με αξιοπιστία, πρέπει να αγοράσετε καινούργιες μπαταρίες. Μπαταρίες αποφορτισμένες – αντικατάσταση Όταν οι μπαταρίες αποφορτιστούν εντελώς, το σύμβολο της μπαταρίας AM αναβοσβήνει μόλις το όργανο ενεργοποιείται (εμφανίζεται μια αποφορτισμένη μπαταρία). Δεν μπορείτε να πραγματοποιήσετε άλλες μετρήσεις και πρέπει να αντικαταστήσετε τις μπαταρίες. 1. Ανοίξτε τη θήκη των μπαταριών 4 στην κάτω πλευρά της συσκευής. 2. Αντικαταστήστε τις μπαταρίες – βεβαιωθείτε ότι η πολικότητα είναι σωστή σύμφωνα με τα σύμβολα στη θήκη. 3. Για να ρυθμίσετε την ημερομηνία και ώρα, ακολουθήστε τη διαδικασία που περιγράφεται στην «Ενότητα 2.». Στη μνήμη διατηρούνται όλες οι τιμές, με εξαίρεση την ημερομηνία και την ώρα που πρέπει να επαναρρυθμιστούν – ο αριθμός έτους αναβοσβήνει αυτόματα μετά την αντικατάσταση των μπαταριών. Ποιες μπαταρίες και ποια διαδικασία Χρησιμοποιείτε 4 καινούργιες, μακράς διαρκείας, αλκαλικές μπαταρίες 1,5 V, μεγέθους AA. Μη χρησιμοποιείτε τις μπαταρίες μετά το πέρας της ημερομηνίας λήξης τους. Αφαιρέστε τις μπαταρίες, εάν δεν πρόκειται να χρησιμοποιήσετε το όργανο για μεγάλο χρονικό διάστημα.     Χρήση επαναφορτιζόμενων μπαταριών Το όργανο μπορεί επίσης να λειτουργήσει με επαναφορτιζόμενες μπαταρίες. Χρησιμοποιείτε μόνο επαναφορτιζόμενες μπαταρίες τύπου «NiMH»! Εάν εμφανιστεί το σύμβολο της μπαταρίας (αποφορτισμένες μπαταρίες), πρέπει να αφαιρείτε τις μπαταρίες και να τις επαναφορτίζετε! Δεν πρέπει να παραμένουν μέσα στο όργανο, διότι ενδέχεται να υποστούν ζημιά (πλήρης αποφόρτιση λόγω περιορισμένης χρήσης του οργάνου, ακόμη κι αν έχει τεθεί εκτός λειτουργίας). Αφαιρείτε πάντοτε τις επαναφορτιζόμενες μπαταρίες, εάν δεν πρόκειται να χρησιμοποιήσετε το όργανο επί μία εβδομάδα ή περισσότερο! Οι μπαταρίες ΔΕΝ μπορούν να φορτιστούν όταν βρίσκονται μέσα στο πιεσόμετρο! Πρέπει να επαναφορτίζετε αυτές τις μπαταρίες σε εξωτερικό φορτιστή και να παρατηρείτε τις ενδείξεις σχετικά με τη φόρτιση, τη φροντίδα και τη διάρκεια ζωής!     BP A3 Plus 8. Χρήση μετασχηματιστή ρεύματος Το όργανο μπορεί να λειτουργήσει με το μετασχηματιστή ρεύματος Microlife (DC 6V, 600 mA). Χρησιμοποιείτε μόνο το τροφοδοτικό Microlife, διαθέσιμο ως πρωτότυπο εξάρτημα κατάλληλο για την παροχή σας ρεύματος. Βεβαιωθείτε ότι δεν έχει προκληθεί ζημιά ούτε στο μετασχηματιστή ρεύματος ούτε στο καλώδιο. 1. Συνδέστε το καλώδιο του μετασχηματιστή στη σχετική υποδοχή 5 στο πιεσόμετρο. 2. Συνδέστε το φις του μετασχηματιστή στην πρίζα του τοίχου. Όταν ο μετασχηματιστής ρεύματος είναι συνδεδεμένος, δεν καταναλώνεται ρεύμα από την μπαταρία.   9. Μηνύματα σφάλματος Εάν σημειωθεί κάποιο σφάλμα κατά τη μέτρηση, η μέτρηση διακόπτεται και στην οθόνη εμφανίζεται ένα μήνυμα σφάλματος, π.χ. «ERR 3». Σφάλμα Περιγραφή Πιθανή αιτία και αντιμετώπιση «ERR 1» Σήμα πολύ Τα σήματα παλμών στην περιχειρίδα ασθενές είναι πολύ ασθενή. Επανατοποθετήστε την περιχειρίδα και επαναλάβετε τη μέτρηση.* «ERR 2» Σήμα σφάλ- Κατά τη μέτρηση, ανιχνεύθηκαν σήματα BN ματος σφάλματος από την περιχειρίδα, τα οποία προκλήθηκαν για παράδειγμα από κίνηση του ατόμου ή σφίξιμο των μυών. Επαναλάβετε τη μέτρηση, κρατώντας το βραχίονά σας ακίνητο. «ERR 3» Δεν Δεν μπορεί να δημιουργηθεί επαρκής BK υπάρχει πίεση στην περιχειρίδα. Ενδέχεται να πίεση στην υπάρχει διαρροή. Βεβαιωθείτε ότι η περιχειρίδα περιχειρίδα έχει συνδεθεί σωστά και ότι δεν έχει χαλαρώσει. Αντικαταστήστε τις μπαταρίες εάν είναι απαραίτητο. Επαναλάβετε τη μέτρηση. «ERR 5» Μη φυσιο- Τα σήματα μέτρησης είναι ανακριβή και λογικό συνεπώς δεν μπορεί να εμφανιστεί αποτέλεσμα κάποιο αποτέλεσμα στην οθόνη. Διαβάστε τη λίστα ελέγχων για την πραγματοποίηση αξιόπιστων μετρήσεων και στη συνέχεια επαναλάβετε τη μέτρηση.* 69 GR Σφάλμα Περιγραφή Πιθανή αιτία και αντιμετώπιση «ERR 6» Λειτουργία Παρατηρήθηκαν πολλά σφάλματα στη MAM διάρκεια της μέτρησης στη λειτουργία MAM, με αποτέλεσμα να μην είναι εφικτός ο υπολογισμός ενός τελικού αποτελέσματος. Διαβάστε τη λίστα ελέγχων για την πραγματοποίηση αξιόπιστων μετρήσεων και στη συνέχεια επαναλάβετε τη μέτρηση.* Η πίεση στην περιχειρίδα είναι πολύ «HI» Πολύ γρήγορος υψηλή (πάνω από 299 mmHg) Ή ο παλμός είναι πολύ γρήγορος (πάνω από παλμός ή πολύ υψηλή 200 παλμοί/λεπτό). Χαλαρώστε επί 5 πίεση περι- λεπτά και επαναλάβετε τη μέτρηση.* χειρίδας «LO» Παλμός Ο παλμός είναι πολύ αργός (κάτω από πολύ αργός 40 παλμοί/λεπτό). Επαναλάβετε τη μέτρηση.* * Παρακαλώ συμβουλευτείτε άμεσα το γιατρό σας, εάν αυτό ή οποιοδήποτε άλλο πρόβλημα παρουσιάζεται επανειλημμένα. Εάν θεωρείτε ότι τα αποτελέσματα της μέτρησης δεν είναι φυσιολογικά, διαβάστε προσεκτικά τις πληροφορίες στην «Ενότητα 1.».  10. Ασφάλεια, φροντίδα, έλεγχος ακρίβειας και απόρριψη  Ασφάλεια και προστασία  Ακολουθήστε τις οδηγίες χρήσης. Αυτό το έγγραφο παρέχει σημαντικές πληροφορίες σχετικά με τη λειτουργία του προϊόντος και την ασφάλεια αυτής της συσκευής. Διαβάστε προσεκτικά αυτό το έγγραφο πριν χρησιμοποιήσετε τη συσκευή και κρατήστε το για μελλοντική αναφορά.  H συσκευή αυτή πρέπει να χρησιμοποιείται για το σκοπό που περιγράφεται στο παρόν έντυπο οδηγιών. Ο κατασκευαστής δεν φέρει καμία ευθύνη για τυχόν ζημιά που προκαλείται από λανθασμένη χρήση.  Αυτή η συσκευή αποτελείται από ευαίσθητα εξαρτήματα και πρέπει να το χειρίζεστε με προσοχή. Τηρείτε τις οδηγίες αποθήκευσης και λειτουργίας που περιγράφονται στην ενότητα «Τεχνικά χαρακτηριστικά»!  Προστατεύστε την από: - νερό και υγρασία 70          - ακραίες θερμοκρασίες - κρούση και πτώση - μόλυνση και σκόνη - άμεση έκθεση στον ήλιο - ζέστη και κρύο Οι περιχειρίδες είναι ευαίσθητες και πρέπει να τις χειρίζεστε με προσοχή. Μην αλλάζετε ή χρησιμοποιείτε άλλο είδος περιχειρίδας ή βύσματος (περιχειρίδας) για μέτρηση με αυτή την συσκευή. Φουσκώστε την περιχειρίδα μόνο όταν έχει τοποθετηθεί στο βραχίονα. Μη χρησιμοποιείτε τη συσκευή κοντά σε ισχυρά ηλεκτρομαγνητικά πεδία, όπως κινητά τηλέφωνα ή ραδιόφωνο. Κρατήστε απόσταση τουλάχιστον 3,3 m από αυτές τις συσκευές όταν χρησιμοποιείτε την συσκευή. Μη χρησιμοποιείτε τη συσκευή εάν θεωρείτε ότι έχει υποστεί ζημιά ή εάν παρατηρήσετε κάτι ασυνήθιστο. Ποτέ μην ανοίγετε τη συσκευή. Εάν δεν πρόκειται να χρησιμοποιήσετε τη συσκευή για μεγάλο χρονικό διάστημα, πρέπει να αφαιρείτε τις μπαταρίες. Διαβάστε τις πρόσθετες οδηγίες ασφάλειας στις ενότητες του παρόντος φυλλαδίου. Το αποτέλεσμα μέτρησης που δίδεται από την συσκευή δεν αποτελεί διάγνωση. Δεν αντικαθιστά την ανάγκη συμβουλής γιατρού, ειδικά αν δεν ταιριάζει με τα συμπτώματα του ασθενούς. Μην βασίζεστε μόνο στο αποτέλεσμα μέτρησης, πάντοτε να εξετάζετε άλλα πιθανά συμπτώματα συνυπολογίζοντας την γνώμη του ασθενούς. Συνιστούμε να καλέστε έναν γιατρό ή ένα ασθενοφόρο εάν κριθεί αναγκαίο. Βεβαιωθείτε ότι τα παιδιά δεν χρησιμοποιούν τη συσκευή χωρίς επίβλεψη, διότι ορισμένα μέρη του είναι αρκετά μικρά και υπάρχει κίνδυνος κατάποσης. Να είστε ενήμεροι για τον κίνδυνο στραγγαλισμού σε περίπτωση που αυτή η συσκευή τροφοδοτείται με καλώδια ή σωλήνες. Φροντίδα του πιεσόμετρου Καθαρίζετε το όργανο μόνο με ένα απαλό στεγνό πανί. Καθαρισμός της περιχειρίδας Απομακρύνετε προσεκτικά τυχόν λεκέδες από την περιχειρίδα, χρησιμοποιώντας υγρό πανί και σαπουνάδα. ΠΡΟΕΙΔΟΠΟΙΗΣΗ: Μην πλένετε την περιχειρίδα στο πλυντήριο ρούχων ή στο πλυντήριο πιάτων!  Έλεγχος ακρίβειας Συνιστάται να ελέγχετε την ακρίβεια αυτού του οργάνου κάθε 2 χρόνια ή εάν κτυπηθεί (εάν πέσει κάτω) Απευθυνθείτε στο τοπικό σας τμήμα εξυπηρέτησης πελατών της Microlife για τον σχετικό έλεγχο (βλ. εισαγωγή). Απόρριψη Η απόρριψη των μπαταριών και των ηλεκτρονικών οργάνων πρέπει να πραγματοποιείται σύμφωνα με τους ισχύοντες κανονισμούς, και όχι μαζί με τα οικιακά απορρίμματα. 11. Εγγύηση Η συσκευή αυτή καλύπτεται από 5 ετή εγγύηση που ισχύει από την ημερομηνία αγοράς. Κατά τη διάρκεια αυτής της περιόδου εγγύησης, κατά την κρίση της, η Microlife θα επισκευάσει ή θα αντικαταστήσει το ελαττωματικό προϊόν δωρεάν. Σε περίπτωση ανοίγματος ή τροποποίησης της συσκευής, η εγγύηση ακυρώνεται. Τα ακόλουθα εξαιρούνται από την εγγύηση:  Κόστος και κίνδυνοι μεταφοράς.  Ζημιά που προκλήθηκε από εσφαλμένη εφαρμογή ή μη συμμόρφωση με τις οδηγίες χρήσης.  Ζημιά που προκλήθηκε από διαρροή μπαταριών.  Ζημιά που προκλήθηκε από ατύχημα ή κακή χρήση.  Συσκευασία/υλικό αποθήκευσης και οδηγίες χρήσης.  Τακτικοί έλεγχοι και συντήρηση (βαθμονόμηση).  Αξεσουάρ και ανταλλακτικά: Μπαταρίες, μετασχηματιστής ρεύματος (προαιρετικός). Η περιχειρίδα καλύπτεται με λειτουργική εγγύηση (σφίξιμο φούσκας) 2 ετών. Εάν απαιτείται service εγγύησης, παρακαλώ επικοινωνήστε με τον έμπορο από τον οποίο αγοράστηκε το προϊόν ή με το τοπικό σας service Microlife. Mπορείτε να επικοινωνήσετε με το τοπικό σας service Microlife μέσω της ιστοσελίδας μας: www.microlife.com/support Η αποζημίωση περιορίζεται στην αξία του προϊόντος. Η εγγύηση θα χορηγηθεί εάν το πλήρες προϊόν επιστραφεί συνοδευόμενο με το αρχικό τιμολόγιο. Η επισκευή ή η αντικατάσταση εντός εγγύησης δεν παρατείνει ή ανανεώνει την περίοδο εγγύησης. Οι νομικές αξιώσεις και τα δικαιώματα των καταναλωτών δεν θίγονται από αυτήν την εγγύηση. BP A3 Plus 12. Τεχνικά χαρακτηριστικά 10 - 40 °C / 50 - 104 °F 15 - 95 % μέγιστη σχετική υγρασία Συνθήκες αποθήκευσης: -20 - +55 °C / -4 - +131 °F 15 - 95 % μέγιστη σχετική υγρασία Βάρος: 368 g (συμπ. των μπαταριών) Διαστάσεις: 143 x 85 x 58 mm Διαδικασία μέτρησης: παλμοσκοπική, κατά τη μέθοδο Korotkoff: Φάση I συστολική, Φάση V διαστολική Εύρος τιμών μέτρησης: 20 - 280 mmHg – αρτηριακή πίεση 40 - 200 παλμοί ανά λεπτό – σφύξεις Εύρος απεικονιζόμενων τιμών πίεσης περιχειρίδας: 0 - 299 mmHg Ανάλυση: 1 mmHg Στατική ακρίβεια: πίεση περίπου ± 3 mmHg Ακρίβεια παλμού: ±5 % της τιμής μέτρησης Πηγή τάσης: 4 x 1,5 V αλκαλικές μπαταρίες, μεγέθους AA Μετασχηματιστής συνεχούς ρεύματος (DC) 6V, 600 mA (προαιρετικός) Διάρκεια ζωής περίπου 920 μετρήσεις (με χρήση μπαταρίας: νέων μπαταριών) IP Κατηγορία: IP20 Συμμόρφωση με EN 1060-1 /-3 /-4; IEC 60601-1; πρότυπα: IEC 60601-1-2 (EMC); IEC 60601-1-11 Αναμενόμενη διάρκεια Συσκευή: 5 χρόνια ή 10000 μετρήσεις ζωής: Εξαρτήματα: 2 χρόνια Συνθήκες λειτουργίας: Η συσκευή συμμορφώνεται με τους κανονισμούς Ιατρικών Συσκευών, σύμφωνα με την οδηγία 93/42/EEC. Η εταιρεία διατηρεί το δικαίωμα για αλλαγή των τεχνικών χαρακτηριστικών. 71 GR AR ϡ΍ΩΧΗγϻ΍ν΍έϏ΃ ϱ΃ϥϭΩΑϡΩϟ΍ρϐοαΎϳϘϟ΍ΫϫΕΎΑΫΑΫϟΎΑϡΩϟ΍ρϐοαΎϳϗίΎϬΟϡΩΧΗγϳ ϪΑΡέλϣϭϫϭϕϭϓΎϣϓΔϧγ˺˻ϥγϥϣιΎΧηϷ΍ϯΩϟϡγΟϟ΍ϲϓϝΧΩΗ ρϐονΎϔΧϧ΍ϰοέϣϭˬϡΩϟ΍ρϐοωΎϔΗέ΍ϰοέϣϊϣϡΩΧΗγϳϟΎ˱ϳέϳέγ ˬΝΎόΗέϻ΍ΕΎϣΩϘϣϰοέϣϭˬϝϣ΍ϭΣϟ΍˯Ύγϧϟ΍ϭˬϱέϛγϟ΍ϰοέϣϭˬϡΩϟ΍ Δϧϣγϟ΍ϰοέϣˬΓέϳΧϷ΍ϝΣ΍έϣϟ΍ϲϓϰϠϛϟ΍ϰοέϣˬϥϳϳ΍έηϟ΍ΏϠλΗϭ ϥγϟ΍έΎΑϛϭ ˬίϳίόϟ΍ϥϭΑίϟ΍ αΎϳϘϟ΍ΫΧϷϕϭΛϭϣϲΑρίΎϬΟΩϳΩΟϟ΍ϑϳϻϭέϛϳΎϣϡΩϟ΍ρϐοΔΑϗ΍έϣίΎϬΟ ΍ΩΟϪΑϰλϭϣϭϕϳϗΩˬϝΎϣόΗγϹ΍ρϳγΑϭϫϭϱϭϠόϟ΍ω΍έΫϟ΍ϰϠϋϥϣ ˷ ϥϣϭ˯ΎΑρϷ΍ϊϣϥϭΎόΗϟΎΑίΎϬΟϟ΍΍Ϋϫέ˷ϭρϝίϧϣϟ΍ϲϓ˷ϡΩϟ΍ρϐοΔΑϗ΍έϣϟ *΍ΩΟϲϟΎόϟ΍ϯϭΗγϣϟ΍Ε΍ΫϪγΎϳϗΔϗΩΕΗΑΛ΃ϲΗϟ΍Δϳέϳέγϟ΍Ε΍έΎΑΗΧϹ΍ϝϼΧ ϥΎϣϷ΍ΕΎϣϭϠόϣϭϑ΋Ύυϭϟ΍ϊϳϣΟϡϬϔϟΔϳΎϧόΑΕΎϣϳϠόΗϟ΍ϩΫϫΓ˯΍έϗϰΟέϳ ϱ΃ϙϳΩϟϥΎϛ΍Ϋ·ϭϑϳϻϭέϛϳΎϣΞΗϧϣϝΎϣόΗγΎΑ˱΍ΩϳόγϥϭϛΗϥ΃ϙΩϳέϧ ϥ΋ΎΑίϟ΍ΔϣΩΧΑϝΎλΗϻ΍˯ΎΟέϟ΍ˬέΎϳϏϊρϗΏϠρϟΔΟΎΣϭ΃ϝϛΎηϣϭ΃ˬϝ΍΅γ ϰϠϋέΩΎϗϲϟΩϳλϟ΍ϭ΃ωίϭϣϟ΍ϥϭϛϳγϭϲϠΣϣϟ΍ϑϳϻϭέϛϳΎϣωίϭϣϟ ΓέΎϳίϙϧϛϣϳˬϙϟΫϥϋϻΩΑϭϙΩϠΑϲϓϑϳϻϭέϛϳΎϣωίϭϣϥ΍ϭϧϋϙ΋Ύρϋ· ΕΎϣϭϠόϣϟ΍ϥϣΓέϓϭΩΟΗγΙϳΣwww.microlife.comΕϧέΗϧϹ΍ϰϠϋΎϧόϗϭϣ ΎϧΗΎΟΗϧϣϝϭΣΔϧϳϣΛϟ΍ Microlife AG !±ϙΗΣλϰϠϋυϓΎΣ «BP 3BTO-A» ί΍έρϟ΍ϊοΧϳΙϳΣαΎϳϘϟ΍ΔϳϧϘΗαϔϧίΎϬΟϟ΍΍ΫϫϡΩΧΗγϳ ΔϳϧΎρϳέΑϟ΍ϡΩϟ΍ρϐο˯ΎΑρ΃ΔϳόϣΟϝϭϛϭΗϭέΑϟΎϘ˱ ϓϭΕ΍έΎΑΗΧϼϟί΋΍ϭΟϟΎΑί΋Ύϔϟ΍ (BIHS) ΔϳΩϧϟέϳϻ΍ϭ Microlife BP A3 Plus ϑΎϘϳϹ΍ϝϳϐηΗϟ΍έί① νέόϟ΍ΔηΎη② ω΍έΫϟ΍ϡ΍ίΣαΑϘϣ③ ˯ΎΑέϬϛϟ΍αΑϘϣ④ ΔϳέΎρΑϟ΍ΓέϳΟΣ⑤ ω΍έΫϟ΍ϡ΍ίΣ⑥ ω΍έΫϟ΍ϡ΍ίΣϝλϭϣ ˷ ⑦ ΕΎγΎϳϘϟ΍ργϭΗϣϟϑϳϻϭέϛϳΎϣ MAMΡΎΗϔϣ⑧ ϝϣόΗγϣϟ΍ϝ˷ϭΣϣ⑨  Γέϛ΍Ϋϟ΍ Mέί⑩ Εϗϭϟ΍ρΑοέί⑪ νέόϟ΍ΔηΎη ϝϣόΗγϣϟ΍ΩϳΩΣΗ⑫ ΔϳέΎρΑϟ΍έη΅ϣ⑬ Εϗϭϟ΍ΦϳέΎΗϟ΍⑭ ΔϳοΎΑϘϧϻ΍ΔϣϳϘϟ΍⑮ ΔϳρΎγΑϧϻ΍ΔϣϳϘϟ΍⑯ νΑϧϟ΍ϝΩόϣ⑰ έϭέϣϟ΍˯ϭοέη΅ϣ⑱ MAMϥϣίΕϗϭ⑲ νΑϧϟ΍έη΅ϣ⑳ ω΍έΫϟ΍ϡ΍ίΣϥϣϕϘΣΗϟ΍έη΅ϣ㉑ ΕΎγΎϳϘϟ΍ργϭΗϣϟϑϳϻϭέϛϳΎϣ MAMρϣϧ ㉒ (IHB) ΏϠϘϟ΍ΕΎΑέοϡΎυΗϧ΍ϡΩϋΓέΎη΍㉓ ω΍έΫϟ΍ΔϛέΣέη΅ϣ㉔ Γέϛ΍Ϋϟ΍㉕ ίΎϬΟϟ΍΍Ϋϫϡ΍ΩΧΗγ·ϝΑϗΔϳΎϧόΑΕΎϣϳϠόΗϟ΍΃έϗ· BFρϣϧϪϳϠϋϕΑρϣ˯ίΟ ϑΎΟϪϘΑ΍ 72 ϲΗ΍Ϋϟ΍αΎϳϘϟ΍ϭϡ˷ Ωϟ΍ρϐοϝϭΣΔϣΎϫϕ΋ΎϘΣ ˺ ˷ ˷ ΏϠϘϟ΍ΦοϥϋΞΗΎϧϟ΍ϭϥϳϳ΍έηϟ΍ϲϓϕ ϓΩΗϳϱΫϟ΍ρϐοϟ΍ϭϫ ϡ˷ Ωϟ΍ρϐο ‡ ΔϣϳϘϟ΍ϭ ΎϳϠόϟ΍ ΔϳοΎΑϘϧϻ΍ΔϣϳϘϟ΍ΎϣϫΎϣ΋΍ΩΎϣϬγΎϳϗϡΗϳϥΎΗϣϳϗϪϟϭ˷ϡΩϠϟ  ϰϧΩϷ΍ ΔϳρΎγΑϧϻ΍ ΏϠϘϟ΍ΎϬϳϓϕϔΧϳϲΗϟ΍Ε΍έϣϟ΍ΩΩϋ Ύοϳ΃νΑϧϟ΍ϝΩ˷ όϣϰϟ·ίΎϬΟϟ΍έϳηϳ ‡  ΔϘϳϗΩϟ΍ϲϓ ϥ΃ΏΟϳϭϙΗΣλϰϠϋέΛ΅Ηϥ΃ϥϛϣϳϡ΋΍ΩϝϛηΑΔϳϟΎόϟ΍ϡ˷ Ωϟ΍ρϐοϡϳϗ ‡ ϙΑϳΑρϝΑϗϥϣΞϟΎόΗ ΕυΣϻ΍Ϋ·ΎϬΑϩέΑΧ΃ϭϙΑϳΑρϊϣΎϣ΋΍ΩϙΑΔλΎΧϟ΍˷ϡΩϟ΍ρϐοϡϳϗεϗΎϧ ‡ ϡ˷ Ωϟ΍ρϐοΕ΍˯΍έϗϰϠϋΩϣΗόΗϻΩϛ΄ΗϣέϳϏΕϧϛϭ΃ϱΩΎϋέϳϏΊη ˷ϱ΃ ΍ΩΑ΃ΓΩέϔϧϣϟ΍ ˷ ΎϬΣϳοϭΗΑϙΑϳΑρϡϭϘϳγ ϡ˷ Ωϟ΍ρϐοϡϳϗωΎϔΗέ΍ΏΎΑγ΃ϥϣΩϳΩόϟ΍ϙΎϧϫ ‡ ΔϳϭΩϸϟϥϛϣϳϙϟΫϰϟ·ΔϓΎο·ϡίϠϳΎϣϛΝϼόϟ΍ΎϬϟϡΩϘϳϭέΛϛ΃ϝϳλϔΗΑ ˷ϡΩϟ΍ρϐοωΎϔΗέ΍ϥϣΩΣΗϥ΃ϥϳέϣΗϟ΍ϭϥίϭϟ΍ϑϳϔΧΗϭ˯ΎΧέΗγϻ΍ϕέρϭ ˱Ύοϳ΃ ϥϭΩΝϼϋϱ΃΃ΩΑΗϭ΃ϑϭέυϟ΍ϥϣϑέυϱ΃ΕΣΗϙΗϳϭΩ΃ΕΎϋέΟέϳϐΗ˵ ϻ ‡ ˱ ϻϭ΃ϙΑϳΑρΓέΎηΗγ΍ ϊοΧϳ˷ϡΩϟ΍ρϐοϥΈϓˬΔϟΎΣϟ΍ϭϝϭΫΑϣϟ΍ϲϧΎϣγΟϟ΍ΩϬΟϟ΍ϰϠϋ΍ΩΎϣΗϋ΍ ‡ αϔϧϲϓϙΗΎγΎϳϗΫΧ΄Ηϥ΃ϙϟΫϟΏΟϳϭέΎϬϧϟ΍˯ΎϧΛ΃ΔΗϭΎϔΗϣΕΎΑ˷ϠϘΗϟ ϝϛϝϗϷ΍ϰϠϋϥϳΗ˯΍έϗΫΧ΄ΑϡϗΔΣ΍έϟΎΑέόηΗΎϣΩϧϋϭΔ΋ΩΎϬϟ΍ϑϭέυϟ΍ ΕΎγΎϳϘϠϟργϭΗϣϝϣόΑϡϗϭ ˯Ύγϣϟ΍ϭΡΎΑλϟ΍ϲϓ Γέϣ ΔϔϠΗΧϣΞ΋ΎΗϧ˯Ύρϋ·ϊϳέγΏϗΎόΗΑΎϣϫΫΧ΃ϡΗϥϳγΎϳϘϟ΍ΩΟϲόϳΑρϟ΍ϥϣ ‡ MAMΎϳΟϭϟϭϧϛΗϡ΍ΩΧΗγΎΑ΢λϧϧ΍ΫϬϟ΍ΩΟ ϙϠΗϭΔϳϟΩϳλϟ΍ϲϓϭ΃ϙΑϳΑρϝΑϗϥϣΎϫΫΧ΃ϡΗϲΗϟ΍ΕΎγΎϳϘϟ΍ϥϳΑΕϭΎϔΗϟ΍ ‡ ϥϋ΍ΩΟΔϔϠΗΧϣΕϻΎΣϟ΍ϩΫϫϥ΃ΙϳΣˬ΍ΩΟϲόϳΑρΕϳΑϟ΍ϲϓΓΫϭΧ΄ϣϟ΍ ΎϬοόΑ ΢λϧϧ΍ΫϬϟϙϣΩρϐοϥ΄ηΑΔϗΩέΛϛ΃ΕΎϣϭϠόϣϲρόΗΓΩΩόΗϣϟ΍ΕΎγΎϳϘϟ΍ ‡ MAMΎϳΟϭϟϭϧϛΗϡ΍ΩΧΗγΎΑ ϥϳγΎϳϘϟ΍ϥϳΑΔϳϧΎΛ˺˾ϝϗϷ΍ϰϠϋΓέϳλϗΔΣ΍έΓέΗϓϙέΗ΍ ‡ ϝΑϗϙΑϳΑρέηΗγ΍ˬΏϠϘϟ΍ΕΎΑέοϡΎυΗϧ΍ϡΩϋϥϣϲϧΎόΗΕϧϛ΍Ϋ· ‡ ‡ ˱ ΔϣυΗϧϣϟ΍έϳϏΏϠϘϟ΍ΕΎοΑϧίϣέϝλϔϟ΍Ύοϳ΃ϊΟ΍έίΎϬΟϟ΍ϡ΍ΩΧΗγ΍ ΍ΫϫϡΩΧΗγϣϟ΍ϝϳϟΩϥϣ IHB ˷ ΏϠϘϟ΍ϡυϧϣΩΩέΗϥϣϕϘΣΗϠϟΏγΎϧϣέϳϏνΑϧϟ΍νέϋ ‡ ϥϛϣϳϪϧϷϡυΗϧϣϝϛηΑϙΑιΎΧϟ΍ϡΩϟ΍ρϐοΔΑϗ΍έϣϙϳϠϋϝϣΎΣ Εϧϛϥ· ‡ ˶ ˶ ϙϠϣΣΓέΗϓϝϼΧέϳΑϛϝϛηΑέϳϐΗϳϥ΃ BP A3 Plus ΕΎϳϭΗΣϣϟ΍ϝϭΩΟ ϲΗ΍Ϋϟ΍αΎϳϘϟ΍ϭϡ˷ Ωϟ΍ρϐοϝϭΣΔϣΎϫϕ΋ΎϘΣ˺ ˮϲ˷ϣΩρϐοϡ˷ϳϗ΃ϑϳϛ ‡ ϰϟϭϷ΍ΓέϣϠϟίΎϬΟϟ΍ϝΎϣόΗγ·˻ ΕΎϳέΎρΑϟ΍ϝΎΧΩ· ‡ Εϗϭϟ΍ϭΦϳέΎΗϟ΍Ω΍Ωϋ· ‡ ΢ϳΣλϟ΍ω΍έΫϟ΍ϡ΍ίΣέΗΧ· ‡ ϡΩΧΗγϣϟ΍ΩϳΩΣΗ ‡ MAMρϣϧϭ΃ϲγΎϳϗαΎϳϘϟ΍ρϣϧέΗΧ· ‡ ΎϬϣ΍ΩΧΗγ΍Δϳϣϫ΄Α΢λϧϧ MAMρϣϧ ‡ ϡΩϟ΍ρϐοαΎϳϘΑ΃ΩΑ΍˼ Γ˯΍έϗϥϳίΧΗϡΩϋΔϘϳέρ ‡  IHB ΏϠϘϟ΍ΕΎΑέοϡΎυΗϧ΍ϡΩϋΓέϟΎη΍έϭϬο˽ νέόϟ΍ϲϓΔϳ΋ϭοϟ΍Ε΍έη΅ϣϟ΍ ˾ ΕΎϧΎϳΑϟ΍Γέϛ΍Ϋ˿ ΔϧίΧϣϟ΍Ξ΋ΎΗϧϟ΍ΓΩϫΎηϣ ‡ Δ΋ϠΗϣϣΓέϛ΍Ϋϟ΍ ‡ ϡϳϘϟ΍ϊϳϣΟ΢γϣ ‡ ΔϳέΎρΑϟ΍έϳϳϐΗϭΔϳέΎρΑϟ΍έη΅ϣ̀ ˯ΎϬΗϧϻ΍ϰϠϋΕΑέΎϗΕΎϳέΎρΑϟ΍ ‡ ϝ΍ΩΑΗγ΍ΕϬΗϧ΍ΕΎϳέΎρΑϟ΍ ‡ ˮ˯΍έΟϹ΍ϭϫΎϣϭΕΎϳέΎρΑϟ΍ωϭϧ ‡ ϥΣηϠϟΔϠΑΎϘϟ΍ΕΎϳέΎρΑϟ΍ϝΎϣόΗγ· ‡ ˯ΎΑέϬϛϟ΍ΔϠλϭϝΎϣόΗγ·́ ΄ρΧϟ΍ϝ΋Ύγέ̂ ίΎϬΟϟ΍ϥϣιϠΧΗϟ΍ϭΔϗΩϟ΍έΎΑΗΧ΍ϭΔϳΎϧόϟ΍ϭΔϣϼγϟ΍˺˹ ΔϳΎϣΣϟ΍ϭΔϣϼγϟ΍ ‡ ίΎϬΟϟΎΑΔϳΎϧόϟ΍ ‡ ω΍έΫϟ΍ϡ΍ίΣϑϳυϧΗ ‡ ΔϗΩϟ΍έΎΑΗΧ΍‡ ίΎϬΟϟ΍ϥϣιϠΧΗϟ΍ ‡ ΔϟΎϔϛϟ΍˺˺ Δϳϧϔϟ΍ΕΎϔλ΍ϭϣϟ΍˺˻ ϲϔϠΧϟ΍ϑϼϐϟ΍έυϧ· ΔϟΎϔϛϟ΍ΔϗΎρΑ  73 AR ΢ϳΣλϟ΍ω΍έΫϟ΍ϡ΍ίΣέΗΧ· ω΍έΫϟ΍ϡ΍ίΣϡΟΣέΎϳΗΧ΍ϙϧϛϣϳω΍έΫϟ΍ϡ΍ίΣϟΔϔϠΗΧϣϡΎΟΣ΃ϑϳϻϭέϛϳΎϣνέόΗ  ϰϠϋϷ΍ω΍έΫϟ΍ίϛέϣϰϠϋϪγΑϠΑϪγΎϳϗϥϛϣϳ ϰϠϋϷ΍ϙϋ΍έΫρϳΣϣϟϡ΋ϼϣϟ΍ ϰϠϋϷ΍ω΍έΫϟ΍ρϳΣϣϟ ω΍έΫϟ΍ϡ΍ίΣϡΟΣ έΗϳϣϳΗϧγ˻˻˺̀ έϳϐλ έΗϳϣϳΗϧγ˼˻˻˻ ργϭ έΗϳϣϳΗϧγ˽˻˻˻ έϳΑϛργϭ έΗϳϣϳΗϧγ˽˻˼˻ έϳΑϛ έΗϳϣϳΗϧγ˾˻-˼˻ (XL)΍ΩΟέϳΑϛέϳΑϛ ϥϣέΑϛ΃έΩϗϰϠϋϝϭλΣϠϟ©ΔϠϬγªΔϳέΎϳΗΧ΍ω΍έΫΔϣίΣ΃έϓϭΗΗ %  ΔΣ΍έϟ΍ϭΔϣ˯ϼϣϟ΍ ϑϳϻϭέϛϳΎϣϥϣω΍έΫϟ΍ϡ΍ίΣρϘϓϝϣόΗγ· %  ω΍έΫϟ΍ϡ΍ίΣϥΎϛ΍Ϋ·ˬϲϠΣϣϟ΍ϑϳϻϭέϛϳΎϣωίϭϣϟϥ΋ΎΑίϟ΍ΔϣΩΧΑϝλΗ΍ _ ϡ΋ϼϣέϳϏ⑥ϕϓέϣϟ΍ αΑϘϣϰϟ·⑦ω΍έΫϟ΍ϡ΍ίΣϝλϭϣϝΎΧΩΈΑίΎϬΟϟ΍ϰϟ·ω΍έΫϟ΍ϡ΍ίΣϝλϭ΃ _ ˷ ΔϳΎϬϧϟ΍ϰΗΣ③ω΍έΫϟ΍ϡ΍ίΣ ϡΩΧΗγϣϟ΍ΩϳΩΣΗ ϥϳλΧηϟϡΩϟ΍ρϐοΕΎγΎϳϗυϔΣ΢ϳΗϳίΎϬΟϟ΍ ˻ϡΩΧΗγϣϭ΃˺ϡΩΧΗγϣ⑨ϡΩΧΗγϣϟ΍ϝ˷ϭΣϣρΑο΍ˬαΎϳϗϝϛϝΑϗ _ user 1ίϣέϰϠϋϰϠϋϸϟ⑨ϝ˷ϭΣϣϟ΍ρΑο΍˺ϡΩΧΗγϣϟ΍ _ user 2 ίϣέϰϠϋϝϔγϸϟ⑨ϝ˷ϭΣϣϟ΍ρΑο΍˻ϡΩΧΗγϣϟ΍ _ user 1έΎΗΧϳϥ΃ΏΟϳϝ˷ϭϷ΍ϡΩΧΗγϣϟ΍  % MAMϊοϭϭ΃ϲγΎϳϘϟ΍ϊοϭϟ΍έΎϳΗΧ΍ ˷ ρϣϧϭ΃ ϲγΎϳϗΩέϔϧϣαΎϳϗ ϲγΎϳϘϟ΍ρϣϧϟ΍έΎϳΗΧ΍ϥϣϙϧϛϣϳίΎϬΟϟ΍΍Ϋϫ ϰϠϋ⑧MAMΡΎΗϔϣϙέΣˬϲγΎϳϘϟ΍ρϣϧϟ΍έΎϳΗΧϻ ϲϟ΁ϲΛϼΛαΎϳϗ MAM ϰϟ·ΡΎΗϔϣϟ΍΍ΫϫϙέΣˬMAMρϣϧέΎϳΗΧϻϭ©˺ªϊοϭϟϝϔγϸϟίΎϬΟϟ΍ΏϧΎΟ ©˼ªϊοϭϟϰϠϋ΃ ΎϬϣ΍ΩΧΗγ΍Δϳϣϫ΄Α΢λϧϧ MAMρϣϧ Ύϳϟ΁ΔΟϳΗϧϟ΍ϝ˷ϠΣΗ˷ϡΛΎϳϟ΁ΔΑϗΎόΗϣΕΎγΎϳϗ˼ΫΧ΃ϡΗϳˬMAMρϣϧϲϓ ‡ ϩΫϬΑΩΩΣΗΗϲΗϟ΍ΔΟϳΗϧϟ΍ϥΈϓϡ΋΍ΩϝϛηΑΏ˷ϠϘΗϳ˷ϡΩϟ΍ρϐοϥϷϭνέόΗϭ ΩέϔϧϣαΎϳϗϥϋΕΟΗϧΓΩΣ΍ϭΔΟϳΗϧϥϣέΛϛ΃ΔϗϭΛϭϣΔϘϳέρϟ΍ ΔηΎηϟ΍ϰϠϋέϬυϳ㉒MAMίϣέϥΈϓΕΎγΎϳϗ˼ρϣϧέΎΗΧΗΎϣΩϧϋ ‡ ˼ϭ΃˻ˬ˺ϡΎϗέϷ΍έϬυϳνέόϟ΍ΔηΎηϥϣϲϠϔγϟ΍ϥϣϳϷ΍˯ίΟϟ΍ ‡ ΎϫΫΧ΃ϡΗϳϲΗϟ΍ΔϳϟΎΣϟ΍˼˰ϟ΍ΕΎγΎϳϘϟ΍ϥϣϱϷΓέΎηϺϟ ϰϟ·έϳηϳϲϟίΎϧΗϟ΍Ωόϟ΍ΕΎγΎϳϘϟ΍ϥϳΑΔϳϧΎΛ˺˾ΓΩϣϟϑϗϭΗΓέΗϓϙΎϧϫ ‡ ϲϘΑΗϣϟ΍Εϗϭϟ΍ ΙϼΛϟ΍ΕΎγΎϳϘϟ΍ΫΧ΃ΩόΑέϬυϳγρϘϓ˷ϡΩϟ΍ρϐοΔϳΩέϔϟ΍Ξ΋ΎΗϧϟ΍νέϋϡΗϳϻ ‡ ΕΎγΎϳϘϟ΍ϥϳΑω΍έΫϟ΍ϡ΍ίΣωίϧΗϻ ‡ Ύϳϟ΁ϊΑ΍έϟ΍αΎϳϘϟ΍ΫΧ΅˵ϳγˬϪϳϓϙϭϛηϣΔϳΩέϔϟ΍ΕΎγΎϳϘϟ΍ΩΣ΃ϥΎϛ΍Ϋ· ‡ 74 ϲϓϡ΍ΩΧΗγϼϟιΎΧϝϛηΑϲϟΎΣϟ΍ϡΩϟ΍ρϐοΔΑϗ΍έϣίΎϬΟέΎΑΗΧ΍ϡΗ %  ϰϠϋΔόϔΗέϣΕ΍˯΍έϗϑΎηΗϛ΍ΔϟΎΣϲϓϝϣΣϟ΍ϡϣγΗϭϝϣΣϟ΍ΕϻΎΣ ϊΑέ΃ΩόΑϯέΧ΃ΓέϣΓ˯΍έϘϟ΍ΫΧ΃ϲϐΑϧϳϓˬϝϣΣϟ΍ϝϼΧΩΎΗόϣϟ΍έϳϏ ϭ΃ΏϳΑρϟ΍ΓέΎηΗγ΍ΏΟϳϓˬΓ˯΍έϘϟ΍ωΎϔΗέ΍έ΍έϣΗγ΍ΔϟΎΣϲϓϭΕΎϋΎγ ˯Ύγϧϟ΍ν΍έϣ΃ΏϳΑρ ˮϲ˷ϣΩρϐοϡ˷ϳϗ΃ϑϳϛ ΕΎϬϳΟϭΗϟ΍ΎϘϓϭϥϳϐϟΎΑϟ΍ϯΩϟϝίϧϣϟΎΑΓΫϭΧ΄ϣϟ΍˷ϡΩϟ΍ρϐοϡϳϗϑϳϧλΗϝϭΩΟ ϲϘΑ΋ίϟ΍έΗϣϲϠϠϣϟΎΑΕΎϧΎϳΑϟ΍(ESHˬ ESCˬ JSH)ΔϳϟϭΩϟ΍ ΔϳλϭΗϟ΍ ϲρΎγΑϧϻ΍ ϲΗ΍ΫιΣϓ <̀˽ ϲοΎΑϘϧϻ΍ <˺˻˹ ϯΩϣϟ΍ ϲόϳΑρϡ˷ Ωϟ΍ρϐο ˺ ϲΗ΍ΫιΣϓ ̀̂̀˽ ˺˻̂˺˻˹ ϲΗ΍ΫιΣϓ ́˽́˹ ˺˼˽˺˼˹ ϝΛϣϷ΍˷ϡΩρϐο ˻ ϡ˷ Ωϟ΍ρϐοϰϠϋ΃ ˼ ϊϔΗέϣ˷ϡΩϟ΍ρϐο ˽ ΔϳΑρΓέΎηΗγϻΝΎΗΣΗ ̂̂́˾ ˺˾̂˺˼˾ ΓέΎηΗγϻΝΎΗΣΗ •˺˹˹ •˺˿˹ ϊϔΗέϣ˷ϡΩϟ΍ρϐο ˾ έρΧϝϛηΑ ΔϠΟΎϋΔϳΑρ ˷ ϥϣϡΩϟ΍ρϐοΔϣϳϗϥ·ϝΎΛϣϡϳϳϘΗϟ΍ΩΩΣΗϲΗϟ΍ϲϫϰϠϋϷ΍ΔϣϳϘϟ΍ϥ· ©΍ΩΟϊϔΗέϣ˷ϡΩϟ΍ρϐοªϰϟ·έϳηΗϲϘΑ΋ίέΗϣϳϠϣ˺˼˹̂˹ϭ΃˺˽˹́˹ ϰϟϭϷ΍ΓέϣϠϟίΎϬΟϟ΍ϝΎϣόΗγ· ˻ ΕΎϳέΎρΑϟ΍ϝΎΧΩ· ˱ ΔϳέΎρΑϟ΍ΓέϳΟΣΩΟϭΗϻϭ΃ΕΎϳέΎρΑϟ΍ϝΧΩ΃ˬΔΑϠόϟ΍ϥϣίΎϬΟϟ΍Ν΍έΧ·ΩόΑ ˬ Εϟϭϓ˺˾AAϡΟΣϥϣ˽ΩΩϋ ΕΎϳέΎρΑϟ΍ϝΧΩ΃ίΎϬΟϟ΍ϝϔγ΃ϲϓ④ ΎϬϳϟ·έΎηϣϟ΍ΔϳΑρϘϟ΍ΔυΣϼϣϡΗϳϰΗΣ Εϗϭϟ΍ϭΦϳέΎΗϟ΍Ω΍Ωϋ· ϙϧϛϣϳΔηΎηϟ΍ϰϠϋΔϧγϟ΍ϡϗένϣϭϳˬΓΩϳΩΟϟ΍ΕΎϳέΎρΑϟ΍ΏϳϛέΗΩόΑ ˺ ϰϠϋρϐο΍ˬέϬηϟ΍ϥϳϳόΗϭΩϳϛ΄ΗϠϟ⑩MέίϰϠϋρϐοϟΎΑΔϧγϟ΍ΩϳΩΣΗ ⑪Εϗϭϟ΍έί ϥϣϭΩϳϛ΄ΗϠϟΕϗϭϟ΍έίϰϠϋρϐο΍ϭέϬηϟ΍ϥϳϳόΗϟMέίϰϠϋρϐο΍ ˻ ϡϭϳϟ΍ϥϳϳόΗϡΛ ϕ΋ΎϗΩϟ΍ϭˬΔϋΎγϟ΍ϭˬϡϭϳϟ΍ϥϳϳόΗϟϩϼϋ΃ΓΩέ΍ϭϟ΍ΕΎϣϳϠόΗϟ΍ϊΑΗ΍ ˼ ϥϳϳόΗϡΗϳˬΕϗϭϟ΍έίϰϠϋρϐοϟ΍ϭϕ΋ΎϗΩϟ΍ϥϳϳόΗϥϣ˯ΎϬΗϧϻ΍ΩέΟϣΑ ˽ Εϗϭϟ΍νέϋϡΗϳΎϣϛˬΕϗϭϟ΍ϭΦϳέΎΗϟ΍ ˱ ΓΩϣϟΕϗϭϟ΍έίϰϠϋϻϭρϣρϐο΍ˬΕϗϭϟ΍ϭΦϳέΎΗϟ΍έϳϳϐΗΩϳέΗΕϧϛ΍Ϋ· ˾ ϡϳϘϟ΍ϝΎΧΩ·ϙϧϛϣϳΎϬϧϳΣνϳϣϭϟ΍ϲϓΔϧγϟ΍ϡϗέ΃ΩΑϳϰΗΣΎ˱ΑϳέϘΗϲϧ΍ϭΛ˼ ϩϼϋ΃ϥϳΑϣϭϫΎϣϛΓΩϳΩΟϟ΍ (IHB ΏϠϘϟ΍ΕΎΑέοϡΎυΗϧ΍ϡΩϋΓέϟΎη΍έϭϬο ˽ ϩΫϫϲϓΔϣυΗϧϣέϳϏΏϠϗΕΎοΑϧϑΎηΗϛ΍ϡΗϪϧ΃ϰϟ·㉓ίϣέϟ΍΍Ϋϫέϳηϳ ϰλϭϳΔϳϠόϔϟ΍ϡΩϟ΍ρϐοϡϳϗϥϋαΎϘϣϟ΍ϡΩϟ΍ρϐοϑέΣϧϳΩϗˬΔϟΎΣϟ΍ αΎϳϘϟ΍έ΍έϛΗΑ IHBΓέΎη΍έϭϬοέ΍έϛΗϝΎΣϲϓΏϳΑρϟ΍ΓέΎηΗγ΍ ˱ Ύοϳ΃νΑϧϟ΍αϳϘϳϲΑΫΑΫΗϟ΍ϡΩϟ΍ρϐοαΎϳϘϟίΎϬΟϥϋΓέΎΑϋίΎϬΟϟ΍΍Ϋϫ ϡυΗϧϣέϳϏΏϠϘϟ΍ΕΎΑέοϝΩόϣϥ΃ϰϟ·έϳηϳϭϡΩϟ΍ρϐοαΎϳϗ˯ΎϧΛ΃ νέόϟ΍ϲϓΔϳ΋ϭοϟ΍Ε΍έη΅ϣϟ΍ ˾ έΎηϣϟ΍ϡΩϟ΍ρϐοΔΟϳΗϧϡϳϳϘΗϙϟέϬυϳ⑱ΔηΎηϟ΍ϥϣϯέγϳϟ΍ΔϓΎΣϟ΍ϰϠϋ  έϣΣϷ΍ ϭ΃ ϲϟΎϘΗέΑ ΔϳϟΎϋ˱΍ΩΟˬ έϔλ΃ ΔόϔΗέϣˬ έέοΧ΃ ΔϳόϳΑρϪϳϟ· ΔϳϬϳΟϭΗϟ΍ΉΩΎΑϣϟ΍ΎϬΗΩΩΣΎϣϛϝϭΩΟϟ΍ϲϓ˽ΕΎϗΎρϧέυΎϧϳϑϳϧλΗϟ΍ΓέϳρΧ ©˺ϡγϘϟ΍ªϲϓ΢οϭϣϭϫΎϣϛˬ(ESH, ESC, JSH)ˬΔϳϟϭΩϟ΍ ΕΎϧΎϳΑϟ΍Γέϛ΍Ϋ ˿ ϡΩΧΗγϣϝϛϟαΎϳϗ̂̂υϔΣΑ˷˱ΎϳϛϳΗΎϣϭΗϭ΃ϡϭϘϳίΎϬΟϟ΍ ΔϧίΧϣϟ΍Ξ΋ΎΗϧϟ΍ΓΩϫΎηϣ ϡΩΧΗγϣϟ΍ϝϭΣϣΔργ΍ϭΑ⑨˻ϭ΃˺ϡΩΧΗγϣϟ΍έΗΧ΍ ΔηΎηνέόΗΊϔρϣίΎϬΟϟ΍ϥϭϛϳΎϣΩϧϋˬΓίϳΟϭΓΩϣϟ⑩Mέίρϐο· ΔϧίΧϣϟ΍ϡϳϘϟ΍ΔϓΎϛργϭΗϣϰϟ·ίϣέϳϱΫϟ΍ˬ«A»ϭ㉕«M»ϻϭ΃νέόϟ΍ ΍έ΍έϣMέίϰϠϋρϐοϟ΍ϭϕΑΎγϟ΍αΎϳϘϟ΍νέόϳMέίϰϠϋρϐοϟ΍ϥ· ˷ ˷ έΧ΁ϭυϔΣϣαΎϳϗϥϳΑϝϘϧΗϟ΍ϥϣϙϧ ϛϣϳ Γ˯ϭϠϣϣΓέϛ΍Ϋϟ΍ ˰ϟ΍ΊϠΗϣΗΎϣΩϧϋαΎϳϗ̂̂ϡΩΧΗγϣϝϛϟϰλϗϷ΍ΩΣϟ΍ϥ΃ϩΎΑΗϧϻ΍ϭΟέϧ  % ϥ΃ϲϐΑϧϳαΎϳϗϡΩϗ΃ϥΎϛϣϝΣΗ˺˹˹ΔϣϳϘϟ΍ϥΈϓˬΓέϛ΍ΫϠϟαΎϳϗ̂̂ ΕΩϘϓϻ·ϭΎϬΗόγϰϟ·Γέϛ΍Ϋϟ΍ϝϭλϭϝΑϗΕΎγΎϳϘϟ΍ϡϳϳϘΗΑΏϳΑρϡϭϘϳ ΕΎϧΎϳΑϟ΍ BP A3 Plus ϡΩϟ΍ρϐοαΎϳϘΑ΃ΩΑ΍ ˼ ϪϳϠϋΩϣΗόϳαΎϳϗΫΧ΃ϥϣΩϛ΄Ηϟ΍Δϣ΋Ύϗ αΎϳϘϟ΍ϝΑϗΓέηΎΑϣϥϳΧΩΗϟ΍ϭ΃ϝϛϷ΍ϭ΃ρΎηϧϝΫΑϯΩΎϔΗ ˺ ϕ΋ΎϗΩ˾ΓΩϣϟΡέΗγ΍ϭέϬυϪϟΩόϘϣϰϠϋαϠΟ΍ ˻ ϥϳόρΎϘΗϣϙϳϗΎγϭαϠΟΗϻϭνέϷ΍ϰϠϋϭΗγϣϝϛηΑϙϳϣΩϗϊο  ˶ ˯ΎΑρϷ΍ϡΎϳϗ΢λϧ˵ϳ Γ˱ ΩΎϋέγϳϷ΍ ϡλόϣϟ΍αϔϧϥϣ˱Ύϣ΋΍ΩαΎϳϘϟ΍ΫΧ ˼ ϝΟ΃ϥϣϰοέϣϠϟϰϟϭϷ΍ΓέΎϳίϟ΍ϝϼΧω΍έΫϠϟΔϳ΋ΎϧΛΕΎγΎϳϗ˯΍έΟΈΑ ΏΟϳΙϳΣϝΑϘΗγϣϟ΍ϲϓαΎϳϘϠϟΎϬϣ΍ΩΧΗγ΍ϡΗϳγϱΫϟ΍ω΍έΫϟ΍ΩϳΩΣΗ ϡΩϟ΍ρϐοϟΓ˯΍έϗϰϠϋ΃ϝΟγϳϱΫϟ΍ω΍έΫϟ΍ϡ΍ΩΧΗγ΍ ϥϭϛΗϻϥ΃ΏΟϳˬνΎΑϘϧϻ΍ϱΩΎϔΗϟϰϠϋϷ΍ω΍έΫϟ΍ϥϋΔϘ˷ϳοϟ΍αΑϼϣϟ΍ωίϧ΍ ˽ ˷ ˷ ΔΣργϣΕϧΎϛ΍Ϋ·ω΍έΫϟ΍ϡ΍ίΣϲϓϝΧΩΗΗϻϲϬϓΔϓϭϔϠϣιϳϣϘϟ΍ϡΎϣϛ΃ ΔϗΎρΑΩΟϭΗ ω΍έΫϟ΍ϡ΍ίΣϟ΢ϳΣλϟ΍αΎϘϣϟ΍ϡ΍ΩΧΗγ΍ϥϣϥϣΩϛ΄Η ˾  ϡ΍ίΣϟ΍ϰϠϋΔϳΣϳοϭΗ ΍ΩΟϕ˷ϳοϝϛηΑαϳϟϥϛϟϥϛϟˬΓέηΎΑϣω΍έΫϟ΍ϡ΍ίΣαΑϟ΍ ‡ ˷ ‡ ˷ ϛ΄Η ϙϋϭϛϕϭϓέΗϣϳΗϧγ˻-˺ΔϓΎγϣϰϠϋϊοϭϳω΍έΫϟ΍ϡ΍ίΣϥ΄ΑΩ ρϳέη ω΍έΫϟ΍ϡ΍ίΣϰϠϋΓΩϭΟϭϣϟ΍ϥΎϳέηϟ΍ΔϣϼϋέϘΗγΗϥ΃ΏΟϳ ‡ ω΍έΫϠϟϲϠΧ΍Ωϟ΍ΏϧΎΟϟ΍ϭΣϧΩΗϣϳϱΫϟ΍ϥΎϳέηϟ΍ϕϭϓ ϡγ˼ϝϭρΑ ˱ΎΣΎΗέϣϥϭϛϳϟϙϋ΍έΫΩϧγ΍ ‡ ˷ ΏϠϘϟ΍ωΎϔΗέ΍αϔϧΑω΍έΫϟ΍ϡ΍ίΣϥ΄ΑΩϛ΄Η ‡ αΎϳϘϟ΍˯ΩΑϟ①ϑΎϘϳ·ϝϳϐηΗέίϰϠϋρϐο΍ ˿ ΔϠοϋΩηΗϻϭϙ ˷έΣΗΗϻˬϲΧέΗγ΍Ύϳϟ΁ϥϵ΍ΦϔΗϧϳγω΍έΫϟ΍ϡ΍ίΣ ̀ ˷ ϡ˷ϠϛΗΗϻϭΩΎΗόϣϝϛηΑαϔϧΗαΎϳϘϟ΍ΔΟϳΗϧέϬυΗϰΗΣϙϋ΍έΫ ˷ ˷ νϔΧϧϳϭΦοϟ΍ϑ ϗϭΗϳˬ΢ϳΣλϟ΍ϯϭΗγϣϟ΍ϰϟ·ρϐοϟ΍ϝλϳΎϣΩϧϋ ́ ˷ ΦοϳγˬΏϭϠρϣϟ΍ρϐοϟ΍ϰϟ·ϝϭλϭϟ΍ϡΗϳϡϟ΍Ϋ·ϲΟϳέΩΗϝϛηΑρϐοϟ΍ ω΍έΫϟ΍ϡ΍ίΣϲϓΎϳϟ΁έΛϛ΃˯΍ϭϫίΎϬΟϟ΍ νέόϟ΍ΔηΎηϲϓ⑳νΑϧϟ΍έη΅ϣνϣϭϳγˬαΎϳϘϟ΍˯ΎϧΛ΃ ̂ ˷ ˺˹ ϊϣνέό˵Ηϭ⑯ϲρΎγΑϧϻ΍ϭ⑮ϲοΎΑϘϧϻ΍˷ϡΩϟ΍ρϐοϝϣηΗˬΔΟϳΗϧϟ΍ϥ· ΏϳΗϛϟ΍΍ΫϫϲϓϯέΧϷ΍Ε΍˯΍έϘϟΎΑΔλΎΧϟ΍Ε΍έϳγϔΗϟ΍Ύοϳ΃υΣϻ⑰νΑϧϟ΍ϝΩόϣ ω΍έΫϟ΍ϡ΍ίΣωίϧ΍ˬαΎϳϘϟ΍ΫΧ΃ϥϣίΎϬΟϟ΍ϲϬΗϧϳΎϣΩϧϋ ˺˺  ΔϘϳϗΩ˺ϲϟ΍ϭΣΩόΑ˱Ύϳϟ΁ΔηΎηϟ΍ΊϔρΗ ίΎϬΟϟ΍ϕϠϏ΃˺˻ Γ˯΍έϗϥϳίΧΗϡΩϋΔϘϳέρ ρϐοϟ΍ϲϓέϣΗγ΍Γ˯΍έϘϟ΍νέϋ˯ΎϧΛ΃①ϑΎϘϳ·ϝϳϐηΗέίϰϠϋρϐο΍ ϰϠϋρϐο΍ˬΩϳϛ΄ΗϠϟέίϟ΍έέΣϡΛ㉕«M»έίνϣϭϳϰΗΣέίϟ΍ϰϠϋ ϯέΧ΃Γέϣ ⑩Mέί ϑΎϘϳ·ϝϳϐηΗέίϰϠϋρϐοϟΎΑϥΎϛΕϗϭϱ΃ϲϓαΎϳϘϟ΍ϑϗϭΗϥ΃ϙϧϛϣϳ  %  ΢ϳέϣέϳϏρϐοαΎγΣ·ϭ΃ΡΎϳΗέϻ΍ϡΩόΑέόηΗΕϧϛ΍Ϋ·ϙϟΫϰϠϋϝΎΛϣϭ ΩϳΟϟ΍ϥϣϥϭϛϳΩϘϓˬ΍Ω˱ ΟϊϔΗέϣϲοΎΑϘϧϻ΍ϡΩϟ΍ρϐοϥ΃ϡϭϠόϣϟ΍ϥϣϥΎϛ΍Ϋ· %  ϡΎϳϗΩόΑϝϳϐηΗϑΎϘϳ·ϝϳϐηΗέίϰϠϋρϐο΍ϱΩέϓϝϛηΑρϐοϟ΍ϥϳϳόΗ ϰϠϋέϫΎυ Ύ˱ΑϳέϘΗϲϘΑ΋ίέΗϣϳϠϣ˼˹ϯϭΗγϣϰΗΣΦοϟΎΑϡΩϟ΍ρϐοΏϗ΍έϣ ˽˹ϲϟ΍ϭΣϰϟ·ρϐοϟ΍ϝλϳϰΗΣέίϟ΍ϰϠϋρϐοϟ΍ϲϓέϣΗγ΍ ΔηΎηϟ΍ έίϟ΍έέΣϡΛ±ΔόϗϭΗϣϟ΍ΔϳοΎΑϘϧϻ΍ΔϣϳϘϟ΍ϕϭϓϲϘΑ΋ίέΗϣϳϠϣ 75 AR ˯ΎΑέϬϛϟ΍ΔϠλϭϝΎϣόΗγ΍ ́ έΎϳΗϠϟϑϳϻϭέϛϳΎϣϝϭΣϣΔϠλϭϝΎϣόΗγΎΑίΎϬΟϟ΍΍Ϋϫϝϐ˷ ηΗϥ΃ϙϧϛϣϳ  έϳΑϣ΃ϲϠϠϣ˿˹˹ˬΕϟϭϓ˿έηΎΑϣέΎϳΗ ϲ΋ΎΑέϬϛϟ΍ ϕΣϠϣϛέϓϭΗϣϟ΍ϲ΋ΎΑέϬϛϟ΍έΎϳΗϠϟϑϳϻϭέϛϳΎϣϝϭΣϣΔϠλϭρϘϓϝϣόΗγ΍  % ˬΔϳρϟϭϔϠϟΩϳϭίΗϟϲϠλ΃ ϲ΋ΎΑέϬϛϟ΍έΎϳΗϟ΍ϝϭΣϣϙϠγϭ΃ΔϠλϭϑϠΗϡΩϋϥϣΩϛ΄Η  % ίΎϬΟϲϓ④ϲ΋ΎΑέϬϛϟ΍έΎϳΗϟ΍ϝϭΣϣΔϠλϭαΑϘϣϰϟ·ΔϠλϭϟ΍ϙϠγϝΧΩ΃ ˺ ˷ϡΩϟ΍ρϐοΔΑϗ΍έϣ ρ΋ΎΣϟ΍αΑϘϣϰϟ·ϲ΋ΎΑέϬϛϟ΍έΎϳΗϟ΍ϝϭΣϣϟ΍αΑΎϗϝΧΩ΃ ˻ ΔϳέΎρΑϟ΍έΎϳΗϙϼϬΗγ΍ϡΗϳϻˬΔϟϭλϭϣϲ΋ΎΑέϬϛϟ΍έΎϳΗϟ΍ϝϭΣϣΔϠλϭϥϭϛΗΎϣΩϧϋ ΄ρΧϟ΍ϝ΋Ύγέ ̂ ϝΎΛϣϭˬ΄ρΧΔϟΎγένέόΗϭαΎϳϘϟ΍ΔόρΎϘϣϡΗϳˬαΎϳϘϟ΍˯ΎϧΛ΃΄ρΧΙΩΣ΍Ϋ· ©ERR 3ªϙϟΫϰϠϋ ϪΟϼϋϭϝϣΗΣϣϟ΍ΏΑγϟ΍ ϑλϭϟ΍ ΄ρΧϟ΍ ˷ ΔϔϳόοΓέΎηϹ΍ ©ERR 1ª Δϔϳόο ω΍έΫϟ΍ ϡ΍ίΣ ϰϠϋ νΑϧϟ΍ Ε΍έΎη· ΕϧΎϛ ϥ· αΎϳϘϟ΍έ΍έϛΗϭω΍έΫϟ΍ϡ΍ίΣϊοϭΓΩΎϋ·ϡΗϳ΍ΩΟ ΍ΩΟ Δργ΍ϭΑ ΄ρΧϟ΍ Ε΍έΎη· ϑΎηΗϛ΍ ϡΗ ˬαΎϳϘϟ΍ ˯ΎϧΛ΃ έ˷ΗϭΗϥϣϝΎΛϣϟ΍ϝϳΑγϰϠϋΔΟΗΎϧϟ΍ˬω΍έΫϟ΍ϡ΍ίΣ ˱ΎϧϛΎγϙϋ΍έΫϲϘΑ΃ˬαΎϳϘϟ΍έ ˷έϛΔϛέΣϟ΍ϭ΃ΔϠοόϟ΍ ΎϣΑέ ω΍έΫϟ΍ ϡ΍ίΣ ϲϓ ϲϓΎϛ ρϐο έϳϓϭΗ ϥϛϣϳ ϻ ˷ ω΍έΫϟ΍ϡ΍ίΣϥ΃ϥϣϕϘΣΗΙΩΣΩϗΏ ˷έγΗϙΎϧϫϥϭϛϳ ϝΩΑΗγ΍ ΍ΩΟ ˱ΎϳΧέϣ αϳϟϭ ΢ϳΣλ ϝϛηΑ ϝλϭϣ αΎϳϘϟ΍ΫΧ΃ΓΩΎϋΈΑϡϗΎϳέϭέοϙϟΫϥΎϛ΍Ϋ·ΕΎϳέΎρΑϟ΍ ΔΟϳΗϧέϬυΗϥ΃ϥϛϣϳϻϭΔϘϳϗΩέϳϏαΎϳϘϟ΍Ε΍έΎη· ϙϟΫΩόΑϭΔϗϭΛϭϣϟ΍ΕΎγΎϳϘϟ΍ΫΧϷϕϳϗΩΗϟ΍Δϣ΋Ύϗ΃έϗ΍ αΎϳϘϟ΍έ ˷έϛ ˬMAMρϣϧϲϓαΎϳϘϟ΍˯ΎϧΛ΃˯ΎρΧϷ΍ϥϣέϳΛϛϟ΍ϙΎϧϫ Δϳ΋ΎϬϧΔΟϳΗϧϰϠϋϝϭλΣϟ΍ϝϳΣΗγϣϟ΍ϥϣϪϠόΟϳΎϣϣ ϙϟΫΩόΑϭΔϗϭΛϭϣϟ΍ΕΎγΎϳϘϟ΍ΫΧϷϕϳϗΩΗϟ΍Δϣ΋Ύϗ΃έϗ΍ *αΎϳϘϟ΍έ ˷έϛ ˷ ˻̂̂ϥϣέΛϛ΃΍ΩΟϲϟΎϋω΍έΫϟ΍ϡ΍ίΣϲϓρϐοϟ΍ϥ· ΔοΑϧ˻˹˹ϥϣέΛϛ΃΍ΩΟϊϔΗέϣνΑϧϟ΍ϥ΃ϭ΃ϲϘΑ΋ίϡϠϣ *αΎϳϘϟ΍έ ˷έϛϭϕ΋ΎϗΩ˾ΓΩϣϟϲΧέΗγ΍ΔϘϳϗΩϟ΍ϲϓ ΔϘϳϗΩϟ΍ϲϓΔοΑϧ˽˹ϥϣϝϗ΃΍ΩΟνϔΧϧϣνΑϧϟ΍ *αΎϳϘϟ΍έ ˷έϛ ΄ρΧΓέΎη· ©ERR 2ª ㉔ ρϐοΩΟϭϳϻ ©ERR 3ª ω΍έΫϟ΍ϡ΍ίΣϲϓ ㉑ ˷ ΓΫΎηΔΟϳΗϧϟ΍ ©ERR 5ª MAMρϣϧ ©ERR 6ª ρϐοϭ΃νΑϧϟ΍ ϡ΍ίΣ ΍ΩΟϲϟΎϋω΍έΫϟ΍ ©HIª νϔΧϧϣνΑϧϟ΍ ΍ΩΟ ©LOª ϯέΧ΃ΔϠϛηϣϱ΃ΙϭΩΣέ΍έϛΗΩϧϋϭ΃ϙϟΫΙΩΣϥ·έϭϔϟ΍ϰϠϋϙΑϳΑρΓέΎηΗγ΍˯ΎΟέΑ ϲϓΕΎϣϭϠόϣϟ΍΃έϘΗϥ΃ϰΟέϳˬΔϳΩΎϋέϳϏΞ΋ΎΗϧϟ΍ϥ΄ΑΩϘΗόΗΕϧϛ΍Ϋ·  % ΔϳΎϧόΑ«˺ϡγϘϟ΍» 76 ΕΎγΎϳϘϟ΍ϊϳϣΟ΢γϣ ΢ϳΣλϟ΍ϡΩΧΗγϣϟ΍ΩϳΩΣΗϥϣΩϛ΄Η ϥϭϛϳΎϣΩϧϋϙϟΫϭˬ⑨user 2ϭ΃user 1ϰϠϋϡΩΧΗγϣϟ΍ϝ˱ϭΣϣρΑο΃ ˺ ˴Ύ΋ϔρϣίΎϬΟϟ΍ ˱ ϭρϣρϐο΍ ˻ ϙόΑλ΍ϊϓέ΍ϡΛ©CLªίϣέέϭϬυϰΗΣ⑩MέίϰϠϋϻ˷ ΩΩΣϣϟ΍ιΧηϠϟΕΎγΎϳϘϟ΍ϝϛϭΣϣϡΗϳϟΓΩΣ΍ϭΓ ˷έϣMέίρϐο΍ϭΩϋ ˼ ϝϳϐηΗέίϰϠϋρϐοϟ΍έΑϋίΎϬΟϟ΍˯ΎϔρΈΑϡϗΕΎγΎϳϘϟ΍ϭΣϣ˯ΎϐϟϹ %  ©CLªίϣέέϭϬυΩϧϋ①ϑΎϘϳ· ΢γϣΗϥ΃ϥϛϣϳϻΔϳΩέϔϟ΍ΕΎγΎϳϘϟ΍  % ΔϳέΎρΑϟ΍έϳϳϐΗϭΔϳέΎρΑϟ΍έη΅ϣ ̀ ˯ΎϬΗϧϻ΍ϰϠϋΕΑέΎϗΕΎϳέΎρΑϟ΍ νϣϭϳγ⑬ΔϳέΎρΑϟ΍ίϣέϥΈϓΎΑϳέϘΗΕΎϳέΎρΑϟ΍˽?˼ϝΎϣόΗγ΍ϡΗϳΎϣΩϧϋ έϣΗγϳγίΎϬΟϟ΍ϥ΃ϥϣϡϏέϟΎΑ Δ΋ϠΗϣϣϪΑηΔϳέΎρΑϟ΍νέόΗ ϝϣόϳίΎϬΟϟ΍ϭ ΔϠϳΩΑΕΎϳέΎρΑϰϠϋϝλΣΗϥ΃ΏΟϳˬϕϭΛϭϣϝϛηΑαΎϳϘϟ΍ϲϓ ϝϳΩΑΗΕϬΗϧ΍ΕΎϳέΎρΑϟ΍ ίΎϬΟϟ΍ϝϳϐηΗΩϧϋνϣϭϳγ⑬ΔϳέΎρΑϟ΍ίϣέϥΈϓˬΕΎϳέΎρΑϟ΍ϲϬΗϧΗΎϣΩϧϋ ϥ΃ΏΟϳϭϯέΧ΃ΕΎγΎϳϗ ˷ϱ΃ΫΧ΃ϊϳρΗγΗϻ ΔϳϬΗϧϣΔϳέΎρΑϟ΍νέόΗ ΕΎϳέΎρΑϟ΍ϝΩΑΗγΗ ίΎϬΟϟ΍ϝϔγ΃ϲϓ④ΔϳέΎρΑϟ΍ΓέϳΟΣ΢Ηϓ΍ ˺ ϲϓίϭϣέϟΎΑϥϳΑϣϭϫΎϣϛΔΣϳΣλϟ΍ΔϳΑρϘϟ΍ϥϣΩϛ΄ΗΕΎϳέΎρΑϟ΍ϝΩΑΗγ΍ ˻ ΓέϳΟΣϟ΍ «˻ϡγϘϟ΍»ϲϓ΢οϭϣϟ΍˯΍έΟϹ΍ϊΑΗ΍ˬΕϗϭϟ΍ϭΦϳέΎΗϟ΍Ω΍ΩϋϹ ˼ Εϗϭϟ΍ϭΦϳέΎΗϟ΍ϥϳϳόΗΓΩΎϋ·ϰϟ·ΔΟΎΣϟ΍ϥϣϡϏέϟΎΑϡϳϘϟ΍ΔϓΎϛΑΓέϛ΍Ϋϟ΍υϔΗΣΗ %  ΕΎϳέΎρΑϟ΍ϝ΍ΩΑΗγ΍ΩόΑϙϟΫϰϠϋ˱˯ΎϧΑΎ˱ϳ΋ΎϘϠΗΔϧγϟ΍ϡϗένϣϭϳΙϳΣ± ˮ˯΍έΟ·ϱ΃ϭΕΎϳέΎρΑΔϳ΃ ˷ .AA alkalineϡΟΣΔϳέΎρΑV˺̄˾x˽  % ΎϬ΋ΎϬΗϧ΍ΦϳέΎΗΩόΑΕΎϳέΎρΑϟ΍ϝϣόΗγΗϻ  % ΔϠϳϭρΓΩϣϟίΎϬΟϟ΍ϝϣόΗγϳϥϟ΍Ϋ·ˬΕΎϳέΎρΑϟ΍ϝί΃  % ϥΣηϠϟΔϠΑΎϘϟ΍ΕΎϳέΎρΑϟ΍ϝΎϣόΗγ· ϥΣηϠϟΔϠΑΎϗΕΎϳέΎρΑϝΎϣόΗγΎΑΎοϳ΃ίΎϬΟϟ΍΍Ϋϫϝϐ˷ ηΗϥ΃ϙϧϛϣϳ ΔϳϧΎΛϝΎϣόΗγϼϟΔϠΑΎϘϟ΍ρϘϓ©NiMHªωϭϧΕΎϳέΎρΑϝΎϣόΗγ΍ϰΟέϳ  % ΔϳέΎρΑϟ΍ίϣέέϬυ΍Ϋ·ˬΎϬϧΣηΩΎόϳϭϝ΍ίΗϥ΃ΏΟϳΕΎϳέΎρΑϟ΍  % ΢ΑλΗΩϗΫ·ˬίΎϬΟϟ΍ϝΧ΍ΩϰϘΑΗϻϥ΃ΏΟϳ ΔϳϬΗϧϣΔϳέΎρΑϟ΍ ˬίΎϬΟϠϟνϔΧϧϣϟ΍ϝΎϣόΗγϼϟΔΟϳΗϧϛϝλΣϳϲϠϛϟ΍ώϳέϔΗϟ΍ Γέ ˷έοΗϣ ˷  ΄ϔρϣϥϭϛϳΎϣΩϧϋϰΗΣ ίΎϬΟϟ΍ϝΎϣόΗγ΍ϯϭϧΗϻΕϧϛ΍Ϋ·ˬΎϣ΋΍ΩϥΣηϠϟΔϠΑΎϘϟ΍ΕΎϳέΎρΑϟ΍ϝί΃  % έΛϛ΃ϭ΃ωϭΑγ΃ΓΩϣϟ ϩΫϫϥΣηΩϋ΃ϡΩ˷ ϟ΍ρϐοΔΑϗ΍έϣίΎϬΟϲϓΕΎϳέΎρΑϟ΍ϥΣηΗϥ΃ϥϛϣϳϻ  % ΔϳΎϧόϟ΍ϭϥΣηϟΎΑΔλΎΧϟ΍ΕΎϣϭϠόϣϟ΍υΣϻϭϲΟέΎΧϥΣΎηϲϓΕΎϳέΎρΑϟ΍ ΔϧΎΗϣϟ΍ϭ  Ωϳίϣϟ΍έυϧ΍ έΎΑΗΧϻ΍ΏϳΗέΗϟϲϠΣϣϟ΍ ιϠΧΗϟ΍ ΏΟϭϣΑΔϳϧϭέΗϛϟϹ΍Εϻϵ΍ϭΕΎϳέΎρΑϟ΍ϥϣι˷ϠΧΗϟ΍ϡΗϳϥ΃ΏΟϳ  Δϳϟίϧϣϟ΍ΕΎϳΎϔϧϟ΍ϊϣαϳϟϭˬΎϳϠΣϣΔϘΑρϣϟ΍ΕΎϣϳϠόΗϟ΍ ΔϟΎϔϛϟ΍ ˺˺ ϥΎϣοϟ΍ ϱέγϳ ϻ .˯΍έηϟ΍ ΦϳέΎΗ ϥϣ Δϳ΍ΩΑ Ε΍ϭϧγ 5 ΓΩϣϟ ϥΎϣοΑ ίΎϬΟϟ΍ ΍Ϋϫ ϊΗϣΗϳ ˱ ϭ΃ΡϼλΈΑ©MicrolifeªϡϭϘΗγˬΎϧέϳΩϘΗϟΎϘϓϭϭˬϩΫϫϥΎϣοϟ΍ΓέΗϓϝϼΧ Ύϧ˱ ΎΟϣΏϳόϣϟ΍ΞΗϧϣϟ΍ϝ΍ΩΑΗγ΍ .ϥΎϣοϟ΍ ϝΎρΑ· ϰϟ· ϪϠϳΩόΗ ϭ΃ ίΎϬΟϟ΍ ΢Ηϓ ϱΩ΅ϳ ϥΎϣοϟ΍ϥϣΓΎϧΛΗγϣΔϳϟΎΗϟ΍έλΎϧόϟ΍ ϝϘϧϟ΍έρΎΧϣϭϝϘϧϟ΍ϑϳϟΎϛΗ ‡ ΕΎϣϳϠόΗϟ ϝΎΛΗϣϻ΍ ϡΩϋ ϭ΃ ΢ϳΣλϟ΍ έϳϏ ϕϳΑρΗϟ΍ ϥϋ ΞΗΎϧϟ΍ έέοϟ΍ ‡ ϡ΍ΩΧΗγϻ΍ ΕΎϳέΎρΑϟ΍ΏέγΗϥϋϡΟΎϧϑϠΗ ‡ ϡ΍ΩΧΗγ΍˯ϭγϭ΃ΙΩΎΣϥϋϡΟΎϧϟ΍έέοϟ΍ ‡ ϡ΍ΩΧΗγϻ΍ΕΎϣϳϠόΗϭϥϳίΧΗϟ΍ϑϳϠϐΗϟ΍ϭΔ΋ΑόΗϟ΍Ω΍ϭϣ ‡  ΓέϳΎόϣϟ΍ ΔϳέϭΩϟ΍ΔϧΎϳλϟ΍ϭιΣϔϟ΍ ‡  ϱέΎϳΗΧ΍ ΔϗΎρϟ΍ϝϭΣϣˬΕΎϳέΎρΑϟ΍έΎϳϏϊρϗϭΕ΍έ΍ϭγγϛ΍ ‡ ϥϳϣΎϋΓΩϣϟ ΔϧΎΛϣϟ΍ϕϳο ϲϔϳυϭϥΎϣοΑΓΎρϐϣΔϔϛϟ΍ ˯΍έη ϡΗ ϱΫϟ΍ ϝϳϛϭϟΎΑ ϝΎλΗϻ΍ ϰΟέϳ ˬ ΔΑϭϠρϣϟ΍ ΔϣΩΧϟ΍ ϥΎϣο ΔϟΎΣ ϲϓ MicrolifeΔϣΩΧΑϝΎλΗϻ΍ϙϧϛϣϳΔϳϠΣϣϟ΍MicrolifeΔϣΩΧϭ΃ˬϪϧϣΞΗϧϣϟ΍ www.microlife.com/supportΎϧόϗϭϣϝϼΧϥϣΔϳϠΣϣϟ΍ ΞΗϧϣϟ΍ωΎΟέ·ϡΗ΍Ϋ·ϥΎϣοϟ΍΢ϧϣϡΗϳγΞΗϧϣϟ΍ΔϣϳϗϰϠϋέλΗϘϳνϳϭόΗϟ΍ ϥΎϣοϟ΍ϥϣοϝ΍ΩΑΗγϻ΍ϭ΃ΡϼλϹ΍ϱΩ΅ϳϻΔϳϠλϷ΍ΓέϭΗΎϔϟ΍ϊϣϝϣΎϛϟΎΑ ΕΎΑϟΎρϣϟ΍ϰϠϋϥΎϣοϟ΍΍ΫϫέλΗϘϳϻΎϫΩϳΩΟΗϭ΃ϥΎϣοϟ΍ΓέΗϓΔϟΎρ·ϰϟ· ϥϳϛϠϬΗγϣϠϟΔϳϧϭϧΎϘϟ΍ϕϭϘΣϟ΍ϭ Δϳϧϔϟ΍ΕΎϔλ΍ϭϣϟ΍ ˺˻ ϝϳϐηΗϟ΍ρϭέη ΕϳΎϬϧέϬϓΔΟέΩ˺˹˽˾˹Δϳϭ΋ϣΔΟέΩ˽˹˺˹ ϥϳϳίΧΗϟ΍ρϭέη ΕϳΎϬϧέϬϓΔΟέΩ˺˻˻˽Δϳϭ΋ϣΔΟέΩ˾˹˻˹ ΔϳΑγϧϟ΍ΔΑϭρέϠϟϰλϗϷ΍ΩΣϟ΍̃̂˹˺˾  ϥίϭ˰˰˰˰˰˰˰˰˰ϟ΍ ΕΎϳέΎρΑϟ΍ϥ˷ϣοΗϳϡ΍έΟ˼˿́ ΩΎ˰˰˰˰˰˰ό˰˰˰˰˰˰˰ΑϷ΍ ϡϠϣ˾́î́˾î˺˽˼ Ε΍˯΍έ˰˰˰˰˰˰˰Ο· ϑϭϛΗϭέϛΔϘϳέρϊϣϕϓ΍ϭΗϳˬΏΫΑΫΗϟ΍αΎϳϗ αΎ˰˰˰˰˰˰˰˰˰˰˰˰ϳϘϟ΍ ΔϳρΎγΑϧϻ΍˾ΔϠΣέϣˬΔϳοΎΑϘϧϻ΍˺ΔϠΣέϣ αΎϳϘϟ΍ϯΩ˰ϣ ϡ˷ Ωϟ΍ρϐοϲϘΑ΋ίέΗϣϳϠϣ˻́˹˻˹  νΑϧΔϘϳϗΩϟ΍ϲϓΔοΑϧ˻˹˹˽˹ ρϐονέϋϯΩϣ ω΍έΫϟ΍ϡ΍ίΣ ϲϘΑ΋ίϡϠϣ˻̂̂˹ BP A3 Plus ίΎϬΟϟ΍ϥϣιϠΧΗϟ΍ϭΔϗΩϟ΍έΎΑΗΧ΍ϭΔϳΎϧόϟ΍ϭΔϣϼγϟ΍ ˺˹ ΔϳΎϣΣϟ΍ϭΔϣϼγϟ΍ ΔϳϠϣόϟ΍ϝϭΣΔϣΎϫΕΎϣϭϠόϣΩϧΗγϣϟ΍΍Ϋϫέϓϭϳϡ΍ΩΧΗγϼϟΕ΍ΩΎηέϹ΍ϊΑΗ΍ ‡ ίΎϬΟϟ΍ϡ΍ΩΧΗγ΍ϝΑϗΔϳΎϧόΑΔϘϳΛϭϟ΍ϩΫϫΓ˯΍έϗ˯ΎΟέϟ΍ίΎϬΟϟ΍΍ΫϫΔϣϼγϭ ϝΑϘΗγϣϟ΍ϲϓΎϬϳϟ·ωϭΟέϠϟΎϬΑυΎϔΗΣϻ΍ϭ ϻΕΎϣϳϠόΗϟ΍ϩΫϫϥϣοϪϟϥϳΑϣϟ΍νέϐϠϟρϘϓίΎϬΟϟ΍΍ΫϫϝΎϣόΗγ΍ϥϛϣϳ ‡ ΊρΎΧϟ΍ϡ΍ΩΧΗγϻ΍ΏΑγΑέέοϟ΍Δϳϟϭ΅γϣϊϧΎλϟ΍ϝ˷ϣΣϳϥ΃ϥϛϣϳ υΣϻέΫΣΑΎϬόϣϝϣΎόΗϟ΍ΏΟϳϭΔγΎ ˷γΣΕΎϧ˷ϭϛϣϥϣϑϟ΄ΗϳίΎϬΟϟ΍΍Ϋϫ ‡ Δϳϧϔϟ΍ΕΎϔλ΍ϭϣϟ΍ϡ ˷γϗϲϓΔϧϳΑϣϟ΍ϝϳϐηΗϟ΍ϭϥϳίΧΗϟ΍ϑϭέυ ϥϣίΎϬΟϟ΍ϲϣΣ· ‡ ΔΑϭρέϟ΍ϭ˯Ύϣϟ΍  ΍ΩΟΔϳϟΎόϟ΍Γέ΍έΣϟ΍ΕΎΟέΩ  ρϭϘγϟ΍ϭΕΎϣΩλϟ΍  έΎΑϐϟ΍ϭΙ˷ϭϠΗϟ΍  έηΎΑϣϟ΍αϣηϟ΍˯ϭο  ΓΩϭέΑϟ΍ϭΓέ΍έΣϟ΍  ˷ ‡ ΔϳΎϧόΑϝϣΎόΗϥ΃ΏΟϳϭΔγΎ ˷γΣω΍έΫϟ΍ΔϣίΣ΃ϥ· έΧ΁Ύ ˱ϋϭϧϡΩΧΗγΗϭ΃ϪΑιΎΧϟ΍ϝλϭϣϟ΍ϭ΃ω΍έΫϟ΍ϡ΍ίΣϝΩΑΗγΗϻ ‡ ίΎϬΟϟ΍΍Ϋϫϡ΍ΩΧΗγΎΑαΎϳϘϠϟ ϪΑϳϛέΗϡΗϳΎϣΩϧϋρϘϓω΍έΫϟ΍ϡ΍ίΣΦϔϧ΍ ‡ ϙϠΗϝΛϣΔϳϭϘϟ΍ΔϳγϳρΎϧϐϣϭέϬϛϟ΍ϝϭϘΣϟ΍ϥϣΏέϘϟΎΑίΎϬΟϟ΍ϝϣόΗγΗϻ ‡ ˬΔϳϛϠγϼϟ΍ϭϳΩ΍έϟ΍Ε΍ίϳϬΟΗϭ΃Δϟ΍ϭΟϟ΍ϑΗ΍ϭϬϟ΍ΓίϬΟ΃ϥϋΓέΩΎλϟ΍ έΗϣ˼̄˼ϥϋϝϘΗϻΔϓΎγϣϰϠϋϪΑυϔΗΣ΍ϭ ϱΩΎϋέϳϏέϣ΃ ˷ϱ΃ΔυΣϼϣΩϧϋϭ΃ϑϟΎΗϪ˷ϧ΄ΑΩϘΗόΗΕϧϛ΍Ϋ·ίΎϬΟϟ΍ϝϣόΗγΗϻ ‡ ΍ΩΑ΃ίΎϬΟϟ΍΢ΗϔΗϻ ‡ ΕΎϳέΎρΑϟ΍Δϟ΍ί·ΏΟϳΔϠϳϭρΓΩϣϟίΎϬΟϟ΍ϝϣόΗγΗϡϟ΍Ϋ· ‡ ΏϳΗϛϟ΍΍ΫϫϥϣΔϳΩέϔϟ΍ϡΎγϗϷ΍ϲϓϯέΧϷ΍Δϣϼγϟ΍ΕΎϣϳϠόΗ΃έϗ΍ ‡ ϝΣϣϝΣϳϻϭϬϓ˱ΎλϳΧηΗαϳϟίΎϬΟϟ΍΍ΫϫΎϬϣΩϗϲΗϟ΍αΎϳϘϟ΍ΔΟϳΗϧϰϠϋ‡ νϳέϣϟ΍ν΍έϋ΃ΔϘΑΎρϣϥϛϳϡϟ΍Ϋ·ΎϣϳγϻˬΏϳΑρΓέΎηΗγ΍ϰϟ·ΔΟΎΣϟ΍ ϲΗϟ΍ϯέΧϷ΍ν΍έϋϷ΍ϲϓέυϧϟ΍˱Ύϣ΋΍ΩˬρϘϓαΎϳϘϟ΍ΔΟϳΗϧϰϠϋΩϣΗόΗϻ ΓέΎϳγϭ΃ΏϳΑρ˯ΎϋΩΗγΎΑ΢λϧϳϰοέϣϟ΍ΕΎϘϳϠόΗϭΙΩΣΗϥ΃ϝϣΗΣϳ έϣϷ΍ϡίϟ΍Ϋ·ϑΎόγ· ˯΍ίΟϷ΍νόΑ˭ϑ΍έη·ϥϭΩΑίΎϬΟϟ΍ϥϭϠϣόΗγϳϻϝΎϔρϷ΍ϥ΄ΑΩϛ΄Η έρΧϥϣέΫΣ΍ΎϬϋϼΗΑ΍ϥϛϣϳΙϳΣΑΔϳΎϔϛϟ΍ϪϳϓΎϣΑΓέϳϐλ ίΎϬΟϟ΍΍ΫϫΔϟΎΣϲϓϕΎϧΗΧϻ΍ ίΎϬΟϟΎΑΔϳΎϧόϟ΍ ΔϓΎΟϭαϣϠϣϟ΍ΔϣϋΎϧΔρϭϓϝΎϣόΗγΎΑρϘϓίΎϬΟϟ΍ϑυϧ ω΍έΫϟ΍ϡ΍ίΣϑϳυϧΗ ΔϠϠΑϣεΎϣϗΔόρϗϡ΍ΩΧΗγΎΑω΍έΫϟ΍ϡ΍ίΣϰϠϋϥϣϊϘΑϟ΍Δϟ΍ίΈΑέΫΣϝϛΑϡϗ ϥϭΑΎλΓϭϏέϊϣ ϥϭΣλϟ΍ΔϳϼΟϭ΃ΔϟΎγϐϟΎΑω΍έΫϟ΍ϡ΍ίΣϝγϐΗϻέϳΫΣΗ  ΔϗΩϟ΍έΎΑΗΧ΍ ˷ ϲϛϳϧΎϛϳϣϟ΍ϡ΍Ωρλϻ΍ΩόΑϭ΃ϥϳΗϧγϝϛΔϗΩϠϟίΎϬΟϟ΍΍ΫϫιΣϔΑϲλϭϧ ϑϳϻϭέϛϳΎϣϟϥ΋ΎΑίϟ΍ΔϣΩΧΑϝΎλΗϷ΍ϰΟέϳ ρϘγϳϥ΃ϙϟΫϰϠϋϝΎΛϣϭ 77 AR Ρϭ˰οϭϟ΍ΔΟ ϲϘΑ΋ίϡϠϣ˺ Δ˰ϧϛΎ˰γϟ΍Δϗ ϲϘΑ΋ίϡϠϣ˼“ϥϣορϐοϟ΍ ν˰Α˰ϧϟ΍Δ Γ˯ϭέϘϣϟ΍ΔϣϳϘϟ΍ϥϣ̃˾“ έΩ˰˰˰˰λ AAϡΟΣ˭AlkalineΔϳέΎρΑV˺̄˾x˽ Δ˰ϳρϟϭ˰˰ ϱέΎϳΗΧ΍ έϳΑϣ΃ϲϠϠϣ˿˹˹ˬέηΎΑϣέΎϳΗΕϟϭϓ˿ϲ΋ΎΑέϬϛϟ΍έΎϳΗϟ΍ϝϭΣϣ ΔϳέΎρΑϟ΍έ ΓΩϳΩΟΕΎϳέΎρΑϡ΍ΩΧΗγΎΑ ΕΎγΎϳϘϟ΍̂˻˹ϲϟ΍ϭΣ IP IP20 EN 1060-1 /-3 /-4; IEC 60601-1; α˰˰ϳϳΎϘϣϟ΍ΔϳόΟ IEC 60601-1-2 (EMC); IEC 60601-1-11 ϊϗϭΗϣϟ΍έϣ ΕΎϳγΎϳϗ˺˹˹˹˹ϭ΃Ε΍ϭϧγ˾ίΎϬΟϟ΍ Ε΍ϭϧγ˻Ε΍έ΍ϭγγϛϻ΍ ΔϳΑρϟ΍ΓίϬΟϷΎΑΔλΎΧϟ΍ΕΎϬϳΟϭΗϟ΍ΕΎΑϠρΗϣϊϣίΎϬΟϟ΍΍Ϋϫϕϓ΍ EEC/93/42ΔϳΑέϭϷ΍ΔϳΩΎλΗϗϻ΍ΔϋϭϣΟ ΔϳϧϓΕϼϳΩόΗ˯΍έΟ·ϕΣΑυϔΗ 78 BP A3 Plus 79 AR
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81

Microlife BP A3 Plus Automatic Blood Pressure Monitor Handleiding

Categorie
Bloeddruk eenheden
Type
Handleiding
Deze handleiding is ook geschikt voor