Danfoss CF-RC Remote Controller Installatie gids

Type
Installatie gids
088U0220
GB
Instruction CF-RC Remote Controller
D
Instruktion CF-RC Fernbedienung
DK
Vejledning CF-RC Fjernbetjening
F
Instruction Commande à distance CF-RC
SE
Bruksanvisning CF-RC Fjärrkontroll
PL
Instrukcja obsługi pilota CF-RC
NL
Handleiding CF-RC Afstandsbediening
I
Istruzioni Regolatore a distanza CF-RC
VI.UH.M5.1C Produced by Danfoss Floor Heating Hydronics 08.2009
1
GB
GB
Instruction ............................................................ 3
D
Instruktion ..........................................................19
DK
Vejledning ...........................................................37
F
Instruction ..........................................................53
SE
Bruksanvisning ...................................................69
PL
Instrukcja obsługi ...............................................85
NL
Handleiding ......................................................101
I
Istruzioni ...........................................................119
2
VI.UH.M5.1C Produced by Danfoss Floor Heating Hydronics 08.2009
Instruction CF-RC Remote Controller
VI.UH.M5.1C Produced by Danfoss Floor Heating Hydronics 08.2009
3
GB
GB
Index
10. Figures and illustrations ......................................................A1-A2
1. Functional Overview ...................................................................... 4
2. Installation ..................................................................................... 5
3. Transmission Test ........................................................................... 6
4. Mounting ......................................................................................... 6
5. Menus ............................................................................................. 7
5.1 Rooms .............................................................................................................................. 7
5.2 Program ........................................................................................................................... 9
5.3 Setup ..............................................................................................................................13
5.4 Alarms ............................................................................................................................15
6. Uninstallation .............................................................................. 16
7. Other products for the CF2 system and abbreviations ............. 17
8. Specifications ................................................................................ 17
9. Troubleshooting ........................................................................... 18
4
Instruction CF-RC Remote Controller
VI.UH.M5.1C Produced by Danfoss Floor Heating Hydronics 08.2009
1. Functional Overview
Front – fig. 1
Display
Soft key 1
Soft key 2
Up/down selector
Left/right selector
Icon for system alarm
Icon for communication with Master Controller
Icon for switch to 230V power supply
Icon for low battery level
Note: The Remote Controller has a self-explanatory menu structure, and all settings are easily
carried out with the up/down and left/right selectors in combination with the functions of
the soft keys, which are shown above them in the display.
Back – fig. 2
Back plate/docking station
Battery compartment
Screw hole for wall mounting
Screw and wall plug
Transformer/power supply plug
Note: Remove the strip to connect the enclosed batteries.
Instruction CF-RC Remote Controller
VI.UH.M5.1C Produced by Danfoss Floor Heating Hydronics 08.2009
5
GB
2. Installation
Note:
Install the Remote Controller after you have installed all the Room Thermostats, see g. 5-b
Remove the strip to connect the enclosed batteries
Carry out the assignment of the Remote Controller to the Master Controller within a
distance of 1½m
When the back light in the display is out, the rst touch of a button only activates this light
Activate Install mode on the Master Controller - fig. 3
Use the menu selection button to select the Install mode.
The install LED flashes
Activate Install mode by pressing OK . The install LED goes ON
Activate Install mode on the Remote Controller - fig. 1
When the batteries have been connected, follow the installation guide,
beginning with the selection of language
After the installation process, set time and date. Use the up/down selector
and the left/right selector to carry out the settings. Confirm settings with
OK activated by soft key 1 ( )
The installation process is concluded with the opportunity to name the
rooms in which the Room Thermostats are placed. This makes access to and
handling of the system very easy
In the Name rooms menu, activate the change menu with soft key 2 ( ) to
change the default room names from e.g. MC1 Output 1.2 (Master Controller
1, output 1 and 2) to living room, and conrm with OK. You can also use the
spell…. menu to create other names
When the installation is nished the start up screen will be shown in the
display with the actual time and date on the top. The screen also shows the
actual temperature in the room from the top of the rooms list.
See chapter 5.3 to select another room for the start up screen
Note: Keeping a button activated during settings will make the value change faster
6
Instruction CF-RC Remote Controller
VI.UH.M5.1C Produced by Danfoss Floor Heating Hydronics 08.2009
3. Transmission Test
Initiate a transmission test on the Remote Controller
From the start-up screen, activate the:
Menu
Setup
Link test
Link test menu to activate a test of the wireless transmission between the
Master Controller and the Remote Controller. The status of the link test will be
displayed right after the test has been carried through.
If the link test is not successful:
Try to relocate the Remote Controller in the room
Or install a Repeater Unit (CF-RU, see g. 5 c), and place it between the Master
Controller and the Remote Controller
Note: The link test may take a few minutes depending on the size of the system
4. Mounting
The Remote Controller has been installed – fig. 2
When the Remote Controller has been installed to the
Master Controller (see chapter 2), it can be mounted on the wall by means of
the back plate/docking station . This makes it possible to connect the Re-
mote Controller to a 230V power supply with the included transformer/power
supply plug . When it is not in the docking station, the Remote Controller is
powered by two AA Alkaline 1.5V batteries.
Instruction CF-RC Remote Controller
VI.UH.M5.1C Produced by Danfoss Floor Heating Hydronics 08.2009
7
GB
Before you place the back plate/docking station on the wall, verify the trans-
mission to the Master Controller from the desired location by carrying out a
link test (see chapter 3)
Mount the back plate/docking station on the wall with the screws and wall
plugs
Connect the docking station to a 230V power supply outlet by means of the
transformer/power supply plug
• Place the Remote Controller in the docking station
Note: To extend the transmission range of the CF2 system, up to three Repeater Units can be
installed in a chain – see g. 4
5. Menus
Note: When the back light in the display is out, the rst touch of a button only activates this light.
5.1 Rooms
From the start-up screen, activate the:
Menu
Rooms
Rooms menu to access a list of all the rooms in the system. Select the desired
room with OK to enter the screen for that room. Here you can see information
about the set and actual temperatures:
: Indicates that this room is included in an ongoing time
program (see chapter 5.2)
: Indicates that the Room Thermostat is running low on battery
: Indicates that the value set on the Room Thermostat is beyond the
max./min. limitations set by the Remote Controller
: Indicates that the set temperature is above the actual tempe rature
: Indicates that the set temperature is below the actual temperature
8
Instruction CF-RC Remote Controller
VI.UH.M5.1C Produced by Danfoss Floor Heating Hydronics 08.2009
5.1.1 Options
From the room screen, you can activate an Options menu with access to
several room options:
Set temperature:
Here you can set and lock the set temperature for the Room Thermostat.
Locking prevents adjustment of the set temperature on the Room Thermostat.
Set Min/Max:
Here you can set and lock the minimum and maximum temperatures for the
Room Thermostat. Locking prevents adjustment beyond these limits on the
Room Thermostat.
Change room name:
Here you can change the room names by means of a list of possible room
names or you can use the spell..... menu to key in other names.
Set floor Min/Max:
Here you can set and lock the minimum and maximum floor surface tempera-
tures.
Note: Only available with the Room Thermostat with infrared floor sensor, CF-RF
Setback:
Here you can choose to override the next or ongoing setback period (see chap-
ter 5.2.2).
Cooling:
Here you can disable the cooling function for the room in question.
Note: Only available when the Master Controller is in cooling mode
Instruction CF-RC Remote Controller
VI.UH.M5.1C Produced by Danfoss Floor Heating Hydronics 08.2009
9
GB
5.2 Program
From the start-up screen, activate the:
Menu
Program
Program menu to view the two time programming options:
5.2.1 Period program:
With this program, you can set the room temperature for all Room Thermo-
stats during e.g. a holiday. The start and end date for the program is easily set
in a calendar by means of the up/down and left/right selectors (g. 1- / )
and by conrming each setting with OK. The room temperature and the dura-
tion of the period program are illustrated and finally activated from a detailed
overview for the created program:
5.2.2 Setback program:
In the Program setback menu, you have the opportunity to divide the die rent
rooms into up to six dierent zones - each zone with up to three dierent setback
programs for reduced room temperature at dierent times during the day.
10
Instruction CF-RC Remote Controller
VI.UH.M5.1C Produced by Danfoss Floor Heating Hydronics 08.2009
Options:
Each zone has a screen showing the rooms included in the zone. This provides
access to an Options menu with an Add room function and three Setback
programs (up to).
Add room:
In this menu, all the rooms are followed by a ( ) indicating to what zone each
room has been allocated (see gure below ). As default, all the rooms are
assigned to Zone 1. If new zones are created, the rooms will be moved from
the zone to which they are allocated to the new zone (from zone 1 to zone 3 in
the figure below).
Program 1 - 3:
The Options menu also includes three possible setback programs for each
zone. By means of these, the seven days of the week can be divided into up to
three dierent setback programs with dierent days and setback periods for
each program. The procedure for creating or changing a program is the same
for all the three programs:
Instruction CF-RC Remote Controller
VI.UH.M5.1C Produced by Danfoss Floor Heating Hydronics 08.2009
11
GB
Activate program (1- 3) from the Options menu with OK to select the days for
this program:
Use the up/down and left/right selectors (g. 1- / ) to select the days for
this program by moving them above the horizontal line. Conrm with OK, and
activate the next step to select the time for the setback program.
Select the time for the setback program by setting the times for the periods
during which you want a normal room temperature, indicated by the black
bars above the time line (the periods outside the black bars are the set-
back periods with reduced room temperature). Set the start and end times
by means of the left/right selector and by toggling between them using the
up/down selector (g. 1- / ).
You can remove the second
period with the normal room
temperature by changing the
end time of this period to its
start time:
12
Instruction CF-RC Remote Controller
VI.UH.M5.1C Produced by Danfoss Floor Heating Hydronics 08.2009
The second period with the nor-
mal room temperature can
be added again by means of the
up/down selector and by tog-
gling through the first period .
Conrm the selected time periods with OK to activate the created
program from this overview:
Note: The days selected in the program are indicated by more distinct initial capitals
Cancel program:
A created program can be deleted with the Cancel Program menu leading to
the overview illustrated above.
Note:
In the Options menu, the created programs (1-3) will be indicated by more distinct capitals
If you want to override a setback period in a room, you can do so with the Override setback
function in the Options menu for each room (see chapter 5.1.1)
Instruction CF-RC Remote Controller
VI.UH.M5.1C Produced by Danfoss Floor Heating Hydronics 08.2009
13
GB
Setback temperature
In the Setback program (see chapter 5.2.2), activate the Setback tempera-
ture menu to set the room temperature reduction from 1 to 10°C during
setback periods.
5.3 Setup
From the start-up screen, activate the:
Menu
Setup
Setup menu with access to a variety of information and setting possibilities
for the Remote Controller as well as the entire CF2 system.
Note: As some of the setting possibilities in the Setup menu can aect the conguration
of the CF2 system, and thus also the functioning of the entire application in general, they
should be handled with caution
Languages:
Here you can choose another language than the one selected during the
installation process (see chapter 2).
Date and time:
Provides access to the setting of the date and time. Furthermore, this menu
includes the settings for and activation of the summertime program. This enables
you to congure at what day, week and month the summertime begins and ends.
Alarm:
From this menu, you can switch the Buzzer of the Master Controller (MC)
On/O. The sound only occurs in case of an alarm, also indicated by the red
alarm LED on the Master Controller (see g. 3- ). In the Alarm log, you can
get specific information about the error causing the alarm and the time for its
14
Instruction CF-RC Remote Controller
VI.UH.M5.1C Produced by Danfoss Floor Heating Hydronics 08.2009
registration by the system. This Alarm log saves the latest alarms for later ac-
cess and easy system failure identification.
Start-up screen:
Here you can choose which room temperature you want displayed on the
start-up screen.
Service:
Here you can congure all the outputs of the Master Controller (see g. 5-a) for
either a oor or radiator heating system. With oor heating, you can choose
regulation by means of an On/O or a PWM (Pulse Width Modulation) prin-
ciple. Choosing a radiator system automatically sets the regulation to PWM.
Even a mixed system with floor and radiator heating in separate rooms can be
selected by setting the outputs of the Master Controller individually for each
room to either floor or radiator heating.
Note: When the Master Controller is regulated by PWM, the cycle times are:
Floor heating: 2 hours
Radiator heating: 15 minutes.
In the Service menu, activate the Standby temperature function with OK in
order to set a fixed room temperature for all the Room Thermostats to 5 – 35°C
when the Global standby input is activated on the Master Controller (see
instruction for Master Controller, CF-MC for installation details).
Contrast:
Here you can adjust the contrast of the Remote Controller display.
Link test:
Activates a link test to the Master Controller to test the wireless transmission to
and from the Remote Controller (see chapter 3).
Instruction CF-RC Remote Controller
VI.UH.M5.1C Produced by Danfoss Floor Heating Hydronics 08.2009
15
GB
Identify Master Controller:
This function enables you to identify one specific Master Controller in a system
of up to three Master Controllers. When this function is activated, the Master
Controller, whose identity you wish to reveal, will ash all the output LEDs
from 1 to 10 and back again several times for easy identification.
5.4 Alarms
If an error occurs in the CF2 system, it is indicated by the Master Controller and
directly on the Remote Controller Display:
When the alarm is acknowledged with OK, the Buzzer of the Master Controller
will go O (if set to Sound On, see chapter 5.3), and the CF2 system will switch
to Alarm status as indicated on the start-up screen:
16
Instruction CF-RC Remote Controller
VI.UH.M5.1C Produced by Danfoss Floor Heating Hydronics 08.2009
This indication of Alarm on the Remote Controller and the indication on the
Master Controller will continue until the error that caused the alarm has been
fixed.
An Alarms menu will be present at the top of the Menu list activated from the
start-up screen:
Activating this Alarms menu with OK provides access to an Alarm status
where you can see a description of the error causing the alarm Furthermore,
you can select the Alarm log to get specific information about the error caus-
ing the alarm and the time for its registration by the system. This Alarm log
saves the latest alarms for later access and easy system failure identification.
When no error is causing an alarm, you can access the Alarm log through the
Setup menu (see chapter 5.3).
6. Uninstallation
Resetting the Remote Controller, CF-RC – fig 1:
At the same time, activate the Soft key 1 , the soft key 2 and the down
selector .
The Remote Controller requests conrmation before resetting.
Confirmation with “yes Resets the Remote Controller.
By conrming Reset with “yes” the Remote Controller is now ready for instal-
lation to a Master Controller, CF-MC.
Note: Please see the Master Controller instruction for further details!
Instruction CF-RC Remote Controller
VI.UH.M5.1C Produced by Danfoss Floor Heating Hydronics 08.2009
17
GB
7. Other products for the CF2 system
and abbreviations
Other products for the CF2 system - fig. 5
a) Master Controller, CF-MC: MC
b) Room Thermostat, CF-RS, -RP, - RD and -RF: Room T.
c) Repeater Unit, CF-RU: RU
8. Specifications
Cable length (power supply) 1.8m
Transmission frequency 868.42MHz
Transmission range in buildings (up to) 30m
Number of Repeater Units in a chain (up to) 3
Transmission power < 1mW
Supply voltage 230V a.c.
Ambient temperature 0-50°C
IP class 21
18
Instruction CF-RC Remote Controller
VI.UH.M5.1C Produced by Danfoss Floor Heating Hydronics 08.2009
9. Troubleshooting
Error Indication Possible Causes
Actuator/output (E03) The output of the Master Controller (MC)
or the actuator connected to this output is
short-circuited or disconnected.
Low temperature (E05) The temperature in the room is below 5°C.
(Try to verify the function of the Room
Thermostat by carrying out a link test from it)
Link to Master Controller (E12) The Room Thermostat in the indicated
room has lost the wireless connection to
the Master Controller (MC)
Low bat. in Room T. (E13) The battery level of the Room Thermostat
for the indicated room is low, and the batte-
ries should be replaced
Critical bat. in Room T. (E14) The battery level of the Room Thermostat
for the indicated room is critically low, and
the batteries should be replaced as soon as
possible
Link between MCs (E24) The indicated Master Controllers have lost
their wireless connection
The battery level of the Remote Controller
is low, and the batteries should be replaced
Instruktion CF-RC Fernbedienung
VI.UH.M5.1C Hergestellt von Danfoss Floor Heating Hydronics 08.2009
19
D
D
Inhaltsverzeichnis
1. Funktionsübersicht ...................................................................... 20
2. Installation ................................................................................... 20
3. Funk-Verbindungstest ................................................................. 22
4. Montage - Fig. 2 ............................................................................ 23
5. Menüs ............................................................................................ 23
5.1 Räume ............................................................................................................................24
5.2 Programme zur Temperaturabsenkung ............................................................25
5.3 Setup ..............................................................................................................................30
5.4 Alarme ............................................................................................................................32
6. Deinstallation ............................................................................... 33
7. Andere Produkte für das CF2-System und Abkürzungen ......... 34
8. Technische Daten .......................................................................... 34
9. Fehlersuche ................................................................................... 34
10. Bilder und Zeichnungen ..................................................... A1-A2
20
Instruktion CF-RC Fernbedienung
VI.UH.M5.1C Hergestellt von Danfoss Floor Heating Hydronics 08.2009
1. Funktionsübersicht
Vorderseite – Fig. 1
Anzeige
Taste 1
Taste 2
Auf-/Ab-Wähler
Links-/Rechts-Wähler
Symbol für Systemalarm
Symbol für die Kommunikation mit dem Hauptregler
Symbol für das Umschalten zur 230V-Stromversorgung
Symbol für niedrigen Batterieladezustand
Anmerkung: Die Fernbedienung ist mit einer selbsterklärenden Menüstruktur ausgestattet.
Alle Einstellungen können problemlos über den Auf-/Ab- und den Links-/Rechts-Wähler
zusammen mit der Funktion der Tasten, die direkt über der Anzeige dargestellt sind, durch-
geführt werden.
Rückseite – Fig. 2
Hintere Abdeckung /Kopplungseinrichtung
Batteriefach
Schraubenloch für Wandmontage
Schraube und Dübel
Transformator/Netzkabel
Anmerkung: Entfernen Sie den Streifen, um die beigefügten Batterien zu aktivieren.
2. Installation
Anmerkung:
Installieren Sie die Fernbedienung nach der Installation und Inbetriebnahme aller Stell-
antriebe und Raumthermostate, siehe Fig. 5-b.
Entfernen Sie den Trennstreifen, um die beigefügten Batterien zu aktivieren.
Instruktion CF-RC Fernbedienung
VI.UH.M5.1C Hergestellt von Danfoss Floor Heating Hydronics 08.2009
21
D
Die Zuordnung der Fernbedienung zum Hauptregler muss innerhalb eines Abstands von
1½m erfolgen.
Wenn die Hintergrundbeleuchtung der Anzeige ausgeschaltet ist, wird sie beim ersten
Betätigen einer Taste nur eingeschaltet.
Aktivieren Sie den Installationsmodus an der Fernbedienung - Fig. 1
Sobald die Batterien aktiviert sind, gehen Sie entsprechend der Installations-
anleitung im Display der Fernbedienung vor, beginnend mit der Sprach-
auswahl. Im Display erscheint der Text “Bitte Hauptregler für die Installation
vorbereiten. Wenn fertig, drücken Sie auf o.k. Folgen Sie den Anweisungen
im Display.
Aktivieren Sie den Installationsmodus am Hauptregler - Fig. 3
Verwenden Sie die Taste zur Menüauswahl , um den Installationsmodus zu
wählen. Die Installations-LED “Install” am Hauptregler blinkt.
Aktivieren Sie den Installationsmodus, indem Sie auf OK drücken. Die
Installations-LED wechselt zu EIN. Jetzt Taste Fig 1 für OK drücken. Im
Display der Fernbedienung erscheint der Text “Bitte warten während die Da-
ten synchronisiert werden. Anzeige im Display: “Installation OK” erscheint.
Danach stellen Sie Uhrzeit und Datum ein - Fig. 1. Verwenden Sie für diese
Einstellungen den Auf-/Ab-Wähler und den Links-/Rechts-Wähler (Fig. 1).
Bestätigen Sie die Einstellungen, indem Sie jeweils auf die Taste für OK drük-
ken (Fig. 1).
Sobald die Installation beendet ist, erscheint in der Anzeige der Startbild-
schirm die aktuelle Uhrzeit- und Datumsangabe am oberen Rand. Außerdem
erscheint in der Anzeige die aktuelle Temperatur des Raumes, der als erster
in der Raumliste angegeben ist. Unter Punkt 5.3 wird erklärt, wie Sie einen
anderen Raum für den Startbildschirm wählen.
Anmerkungen:
Über die Menütaste haben Sie die Möglichkeit, diverse Optionen wahrzunehmen:
- Räume benennen (siehe Seite 33) Menü “Räume”
- Heiz-und Absenkzeiten einstellen (siehe Seite 35) Menü “Programm
22
Instruktion CF-RC Fernbedienung
VI.UH.M5.1C Hergestellt von Danfoss Floor Heating Hydronics 08.2009
- diverse Setup-Einstellungen vorzunehmen oder zu verändern (siehe Seite 39),
u.a. Sprache Menü “Setup
- Datum/Uhrzeit (z.B. Umstellung auf Sommerzeit)
- Alarm (Signal oder Alarmbericht)
- Startbildschirm (gewünschte Anzeige)
- Service, z.B. Standby-Betrieb
- Kontrast
- Verbindungstest
Anmerkung: Wenn während der Einstellung eine Taste gedrückt bleibt, ändert sich der Wert
schneller.
3. Funk-Verbindungstest
Starten Sie den Funk-Verbindungstest an der Fernbedienung
Vom Startbildschirm aus aktivieren Sie das Menü:
Menü
Setup
Verbindungstest
Über den Funk-Verbindungstest wird die Funkübertragung zwischen dem
Hauptregler und der Fernbedienung getestet. Der Status des Verbindungstests
wird direkt nach Beendigung des Tests angezeigt. Wenn der Funk-Verbindungs test
erfolgreich war, erfolgt die Display-Meldung “Der Verbindungstest war erfolgreich.
Wenn der Funk-Verbindungstest fehlgeschlagen ist:
• Platzieren Sie die Fernbedienung an anderer Stelle im Raum
Instruktion CF-RC Fernbedienung
VI.UH.M5.1C Hergestellt von Danfoss Floor Heating Hydronics 08.2009
23
D
Oder installieren Sie einen Signalverstärker (CF-RU, siehe Fig. 5 c) zwischen
dem Hauptregler und der Fernbedienung.
Anmerkung: Abhängig von der Systemgröße kann der Funk-Verbindungstest einige Minuten
dauern.
4. Montage - Fig. 2
Sobald die Fernbedienung dem Hauptregler zugeordnet wurde (siehe Kapitel
2, “Installation”), kann sie mit Hilfe der hinteren Abdeckung / Kopplungsein-
richtung an der Wand montiert werden. So kann die Fernbedienung mittels
des beigefügten Transformators / Netzkabels an eine 230V-Stromquelle
angeschlossen werden. Wenn sich die Fernbedienung nicht in der Kopplungs-
einrichtung bendet, wird sie über 2 AA - Alkaline Batterien 1,5 V versorgt.
Vor der Befestigung der hinteren Abdeckung / Kopplungseinrichtung an der
Wand sollte ein Funk - Verbindungstest (siehe Kapitel 3) durchgeführt werden.
Es wird die Funkübertragung von dem gewünschten Montageort geprüft.
Befestigen Sie die hintere Abdeckung / Kopplungseinrichtung mit Hilfe der
Schrauben und Dübel an der Wand.
Schließen Sie die Kopplungseinrichtung mit Hilfe des Transformators / Netz-
kabels an eine 230 V-Stromquelle an.
• Schieben Sie die Fernbedienung in die Kopplungseinrichtung.
Anmerkung: Zur Erweiterung des Sendebereichs des CF2-Systems können bis zu drei Signal-
verstärker in Reihe geschaltet werden – siehe Fig. 4.
5. Menüs
Anmerkung: Wenn die Hintergrundbeleuchtung der Anzeige ausgeschaltet ist, wird sie beim
ersten Betätigen einer Taste nur eingeschaltet.
24
Instruktion CF-RC Fernbedienung
VI.UH.M5.1C Hergestellt von Danfoss Floor Heating Hydronics 08.2009
5.1 Räume
Vom Startbildschirm aus aktivieren Sie den ersten Menüpunkt:
Menü
Räume
Unter Menüpunkt Räume erhalten Sie eine Liste aller Räume im System. Wählen
Sie den gewünschten Raum mit OK und wechseln Sie zum Bildschirm für diesen
Raum. Hier erhalten Sie Informationen über den Temperatursoll- und -istwert:
: gibt an, dass der Raum zu einem laufenden Zeitprogramm gehört
(siehe Kapitel 5.2),
: gibt an, dass der Ladezustand der Batterie im Raumther mostaten
niedrig ist,
: gibt an, dass der eingestellte Wert des Raumthermostaten sich außer-
halb der Min.-/Max.-Grenzen bendet, die über die Fernbedienung
eingestellt wurden,
: gibt an, dass die Sollwerttemperatur über der tatsächlichen Temperatur
liegt,
: gibt an, dass die Sollwerttemperatur unter der tatsächlichen Temperatur
liegt.
5.1.1 Raumoptionen
Anmerkung: Von der Anzeige Räume (5.1) können Sie das Menü Optionen aktivieren
Sollwerttemperaturen, Anzeige: “Sollwerttemp”:
Hier können Sie die gewünschte Raumtemperatur einstellen und blockieren.
Die Blockierung verhindert das Verstellen der Raumtemperatur.
Min.- / Max.- Begrenzung, Anzeige: “Min/Max einstellen”:
Hier können Sie die Mindest- und die Maximaltemperatur einstellen und blok-
kieren. Die Blockierung verhindert das Verstellen der Raumtemperatur.
Instruktion CF-RC Fernbedienung
VI.UH.M5.1C Hergestellt von Danfoss Floor Heating Hydronics 08.2009
25
D
Räume benennen, Anzeige: “Raumnamen ändern”:
Hier können Sie den die Räume anhand einer vorgegebenen Liste mit Raum-
namen benennen oder das Menü Schreiben ..... verwenden, um andere
Namen zu erstellen.
Min.- / Max. Begrenzung der Fußbodentemperatur, Anzeige:
“Boden Min/Max einstellen!”:
Hier können Sie die minimale und die maximal gewünschte Oberächentem-
peratur des Fußbodens einstellen.
Anmerkung: Nur beim Raumthermostaten mit Infrarot-Bodenfühler, CF-RF, verfügbar.
Absenkung:
Hier können Sie wählen, ob Sie das nächste oder das aktuelle Absenkpro-
gramm ändern möchten (siehe Kapitel 5.2.2).
Kühlung:
Hier können Sie die Kühlfunktion für den betreenden Raum deaktivieren.
Anmerkung: Nur verfügbar, wenn sich der Hauptregler im Kühlmodus bendet.
Absenkung:
Hier können Sie die Absenkung für einzelne Räume ignorieren.
Anmerkung: Nur Verfügbar wenn Absenkprogramm (siehe 5.2.2) aktiviert ist
5.2 Programme zur Temperaturabsenkung
Vom Startbildschirm aus aktivieren Sie den zweiten Menüpunkt:
Menü
Programm
Periodenprogramm (5.2.1) und Absenkprogramm (5.2.2)
26
Instruktion CF-RC Fernbedienung
VI.UH.M5.1C Hergestellt von Danfoss Floor Heating Hydronics 08.2009
5.2.1 Periodenprogramm (z.B. Urlaub):
Mit diesem Programm können Sie die Raumtemperatur für alle Raumthermo-
state bei längerer Abwesenheit auswählen. Das Start- und Enddatum für das
Programm wird über einen Kalender mit Hilfe des Auf-/Ab- und des Links-
/Rechtswählers (Fig. 1- / ) eingestellt und mit OK bestätigt. Sie wählen im
Kalender den Tag aus, ab dem die Temperaturen abgesenkt werden sollen und
bestätigen diesen Tag mit OK. Danach führen Sie den Cursor auf den letzten
gewünschten Absenktag und bestätigen diesen wiederum mit OK. Damit
haben Sie die Dauer des Periodenprogramms festgelegt. Das Display zeigt nun
die gewählte Raumtemperatur in °C an. Diesen Temperaturwert können Sie für
die Dauer des Periodenprogramms bis zu einer Mindesttemperatur von 5°C
(Frostschutz) reduzieren. Die gewählten Einstellungen werden nun auf dem
Display angezeigt und müssen mit Ja” aktiviert werden.
5.2.2 Absenkprogramm:
Im Menü Programm Absenkung können Sie die vorhandenen Räume in bis
zu sechs unterschiedliche Zonen unterteilen. Für jede Zone können bis zu drei
Absenkprogramme gewählt werden. Das Display zeigt zunächst alle Räume an.
Auf Wunsch können Räume gleicher Nutzung zusammengefasst werden.
Dieser Vorgang ist im Folgenden beschrieben.
Räume zuordnen (Optionen):
Standardmäßig sind alle Räume der Zone 1 zugeordnet, wie auf dem Display
zu erkennen ist. Diese Zuordnung kann verändert werden, indem eine leere
Instruktion CF-RC Fernbedienung
VI.UH.M5.1C Hergestellt von Danfoss Floor Heating Hydronics 08.2009
27
D
Zone (Zone 2, Zone 3 .... Zone 6) über OK deniert wird. Über den Button
Optionen mit der Funktion Raum hinzufügen lassen sich die gewünschten
Räume einfügen. Diesen Räumen können bis zu bis zu drei Absenkprogramme
zugeordnet werden.
Raum hinzufügen (Zone ... - Optionen):
In diesem Menü steht neben jedem Raum eine Zahl in ( ), die angibt, zu wel-
cher Zone dieser Raum gehört (siehe folgende Abbildung ). Als Standard
sind alle Räume der Zone 1 zugeordnet.
Sind weitere Zonen erforderlich, werden die Räume von der Zone, in der sie
sich aktuell benden, in die neue Zone verschoben (in der Abbildung unten
von Zone 1 zu Zone 3).
Programm 1 - 3:
Das Menü Optionen enthält drei mögliche Absenkprogramme für jede Zone.
Damit kann eine volle Woche in bis zu drei verschiedene Absenkprogramme
mit verschiedenen Tagen und Absenkperioden unterteilt werden. Alle drei
Programme werden auf die gleiche Weise erstellt und geändert:
Anmerkung: Die Programme (1 - 3) sind grau hinterlegt und können ausgewählt werden
28
Instruktion CF-RC Fernbedienung
VI.UH.M5.1C Hergestellt von Danfoss Floor Heating Hydronics 08.2009
Aktivieren Sie das Programm (1- 3) im Menü Optionen mit OK, um die Tage
für dieses Programm zu wählen:
Verwenden Sie die Auf-/Ab- und Links-/Rechts-Wähler (Fig. 1- / ),
um die Tage für dieses Programm zu wählen, indem Sie sie über die horizon-
tale Linie verschieben. Bestätigen Sie mit OK, und aktivieren Sie den nächsten
Schritt, um die Zeit für das Absenkprogramm zu wählen.
Wählen Sie die Zeit für das Absenkprogramm, indem Sie die gewünschten Zei-
ten für die Zeiträume einstellen, in denen Sie eine „normale“ Raumtemperatur
wünschen, die durch die schwarzen Balken über der Zeitlinie angegeben
sind (die Zeiträume außerhalb der schwarzen Balken sind die Absenkzeiten
mit reduzierter Raumtemperatur). Stellen Sie die Start- und Endzeiten mit Hilfe
des Links-/Rechts-Wählers ein, und wechseln Sie mittels des Auf-/Ab-Wählers
zwischen den Zeiten (Fig. 1- / ).
Sie können den zweiten Zeit-
raum mit der „normalen“ Raum-
temperatur entfernen, indem
Sie die Endzeit dieses Zeitraums
als Startzeit setzen:
Anmerkung: Den “Balken soweit
nach links verschieben bis er sich nicht
mehr sichtbar ist
Instruktion CF-RC Fernbedienung
VI.UH.M5.1C Hergestellt von Danfoss Floor Heating Hydronics 08.2009
29
D
Der zweite Zeitraum mit der
„normalen“ Raumtemperatur
kann mit Hilfe des Auf-/Ab-Wäh-
lers und durch das Blättern durch
den ersten Zeitraum wieder
hinzugefügt werden.
Bestätigen Sie die gewählten Perioden mit OK, um das erstellte Absenkprogramm
von dieser Übersicht aus zu aktivieren:
Anmerkung: Die im Programm gewählten Tage sind durch stärker hervorgehobene Anfangs-
buchstaben gekennzeichnet.
Programm abbrechen:
Ein erstelltes Programm kann über das Menü Programm abbrechen gelöscht
werden, wodurch die oben dargestellte Übersicht angezeigt wird.
Anmerkung:
Im Menü Optionen werden die erstellten Programme (1-3) durch stärker hervorgehobene
Anfangsbuchstaben gekennzeichnet.
Wenn Sie ein Absenkprogramm in einem Raum ignorieren möchten, können Sie für jeden
Raum die Funktion Absenkung ignorieren im Menü “Optionen” aktivieren (siehe Kapitel
5.1.1).
30
Instruktion CF-RC Fernbedienung
VI.UH.M5.1C Hergestellt von Danfoss Floor Heating Hydronics 08.2009
Absenktemperatur
Aktivieren Sie im Menü Absenkprogramm (siehe Kapitel 5.2.2) das Menü
Absenktemperatur, um die Raumtemperaturabsenkung von 1 bis 10°C von
der Sollwerttemperatur einzustellen. Hierbei handelt es sich um die Tempera-
turdierenz von eingestellter Raumtemperatur - Absenktemperatur
5.3 Setup
Vom Startbildschirm aus aktivieren Sie den dritten Menüpunkt:
Menü
Setup
Setup bietet Zugri auf verschiedene Informationen und Einstellmöglichkei-
ten für die Fernbedienung und das gesamte CF2-System.
Anmerkung: Einige Einstellmöglichkeiten im Menü Setup können die CF 2 Parameter verän-
dern und xieren.
Sprachen:
Wechsel der Sprache (siehe Kapitel 2).
Datum und Uhrzeit:
Einstellen von Datum, Uhrzeit und Aktivierung der Sommerzeit. Damit können
Sie Tag, Woche und Monat für Anfang und Ende der Sommerzeit einstellen.
Alarm:
Über dieses Menü können Sie den Buzzer (Alarm) des Hauptreglers (MC) ein-
und ausschalten. Standardmäßig ist der akustische Alarm ausgeschaltet. Bei
Alarm blinkt die rote Alarm LED am Hauptregler (siehe Fig. 3- ).
Der Alarmbericht gibt detaillierte Alarminformationen über den Fehler, der den
Alarm ausgelöst hat, und zeigt Alarmdatum und -uhrzeit.
Instruktion CF-RC Fernbedienung
VI.UH.M5.1C Hergestellt von Danfoss Floor Heating Hydronics 08.2009
31
D
Startbildschirm:
Hier können Sie wählen, welcher Raum im Startbildschirm angezeigt werden soll.
Service (Ausgangskonfiguration, Standby - Temperatur):
Hier können Sie alle Ausgänge des Hauptreglers einzeln (siehe Fig. 5 a) entwe-
der für eine Fußbodenheizung oder für Heizkörper kongurieren.
Im Fall einer Fußbodenheizung können Sie zwischen der Ein-Aus-Regelung
oder Pulsweitenmodulation (PWM) wählen.
Wenn Sie einen Heizkörper regeln, wird automatisch die Pulsweitenmodula-
tion eingestellt. Auch gemischte Systeme mit Fußboden- und Heizkörperhei-
zung in verschiedenen Räumen sind möglich. Hierzu werden die Ausgänge
des Hauptreglers individuell für jeden Raum eingestellt.
Anmerkung: Wenn der Hauptregler entsprechend der Pulsweitenmodulation (PWM) arbeitet,
sind die Zykluszeiten:
Fußbodenheizung: 2 Stunden
Heizkörperheizung: 15 Minuten
Aktivieren Sie im Menü Service die Funktion Standby-Temperatur (standard-
mäßig 8 °C) mit OK, damit Sie für alle Raumthermostaten eine feste Raumtem-
peratur von 5 bis 35°C einstellen können. Diese Temperatur gilt sobald der
Global Standby Modus am Hauptregler (MC) aktiviert ist Einzelheiten, siehe
Anleitung zum Hauptregler, CF-MC).
Kontrast:
Hier können Sie den Kontrast der Anzeige an der Fernbedienung einstellen.
Standardmäßig ist ein Wert von 20 eingestellt. Wir empfehlen einen höheren
Kontrast (ca.30).
Verbindungstest:
Aktiviert einen Verbindungstest zum Hauptregler zum Testen der Funkübertra-
gung von und zur Fernbedienung (siehe Kapitel 3).
32
Instruktion CF-RC Fernbedienung
VI.UH.M5.1C Hergestellt von Danfoss Floor Heating Hydronics 08.2009
Hauptregler erkennen (MC):
Mit Hilfe dieser Funktion können Sie einen bestimmten Hauptregler in einem
System erkennen, das aus bis zu drei Hauptreglern besteht. Wenn die Funktion
aktiviert ist, blinken alle Ausgangs-LEDS des Hauptreglers.
5.4 Alarme
Sollte im CF2-System ein Fehler auftreten, wird er vom Hauptregler und unmit-
telbar in der Anzeige der Fernbedienung angegeben:
Wird der Alarm mit OK bestätigt, wechselt das CF 2 System in den Alarmstatus
wie folgt dargestellt, bis der Fehler behoben ist:
Anmerkung: Bei vorher eingeschaltetem akustischen Alarm ertönt der Signalton
Instruktion CF-RC Fernbedienung
VI.UH.M5.1C Hergestellt von Danfoss Floor Heating Hydronics 08.2009
33
D
Ausschließlich bei Alarm wird im (Haupt-) Menü der Menüpunkt Alarm dar-
gestellt:
Wenn Sie das Menü Alarm mit OK bestätigen, erhalten Sie Zugri auf den
Alarmstatus, der eine Beschreibung des Alarm auslösenden Fehlers liefert.
Außerdem können Sie den Alarmbericht wählen, um genaue Informatio-
nen über den Fehler zu erhalten und wann er im System registriert wurde. In
diesem Alarmbericht werden die zuletzt aufgetretenen Alarme gespeichert.
Wenn kein Alarm durch einen Fehler ausgelöst wird, können Sie über das
Menü “Setup” auf den Alarmbericht zugreifen (siehe Kapitel 5.3).
6. Deinstallation
Reset / Zurücksetzen der Fernbedienung CF-RC – Fig. 1:
Betätigen Sie gleichzeitig die Tasten , und den Pfeil-unten Taste
(Siehe Fig. 1).
Das Zurücksetzen der Fernbedienung muss mit „Ja“ bestätigt werden.
Wenn das Zurücksetzen mit Ja” bestätigt wird, kann die Fernbedienung
einem weiteren Hauptregler CF-MC zugeordnet werden.
Anmerkung: Weitere Details entnehmen Sie bitte den Instruktionen des Hauptreglers.
34
Instruktion CF-RC Fernbedienung
VI.UH.M5.1C Hergestellt von Danfoss Floor Heating Hydronics 08.2009
7. Andere Produkte für das CF2-System
und Abkürzungen
Andere Produkte für das CF2-System - Fig. 5
a) Hauptregler, CF-MC: MC
b) Raumthermostat, CF-RS, -RD, -RP und -RF: Raumt.
c) Signalverstärker, CF-RU: RU
8. Technische Daten
Kabellänge (Stromversorgung) 1,8 m
Sendefrequenz 868,42 MHz
Sendebereich in normalen Gebäuden (bis zu) 30 m
Anzahl der Signalverstärker CF-RU in Reihe (bis zu) 3
Sendeleistung < 1mW
Versorgungsspannung 230 V AC und 2 Batterien 1,5 V AA
Alkaline
Umgebungstemperatur 0-50 °C
IP-Klasse 21
Anzahl der Hauptregler CF-MC mit 1
Fernbedienung CF-RC
1, 2, max 3
Instruktion CF-RC Fernbedienung
VI.UH.M5.1C Hergestellt von Danfoss Floor Heating Hydronics 08.2009
35
D
9. Fehlersuche
Fehleranzeige Mögliche Ursachen
Stellantrieb / Ausgang (E03) Der Ausgang des Hauptreglers (MC) oder der mit
diesem Ausgang verbundene Stellantrieb hat
einen Kurzschluss oder ist nicht angeschlossen.
Niedrige Temperatur (E05) Die Temperatur im Raum liegt unter 5°C. (Prüfen
Sie die Funktion des Raumthermostaten durch
einen Verbindungstest).
Verbindung zum MC (E12) Die Funkverbindung zwischen dem Raumther-
mostaten im betreenden Raum und dem
Hauptregler (MC) ist unterbrochen.
Bat. im Raumt. zu niedrig (E13) Der Batterieladezustand im Raumthermostaten
des angegebenen Raums ist niedrig, und die
Batterien sollten erneuert werden.
Bat. im Raumt. kritisch (E14) Der Batterieladezustand im Raumthermostaten
des angegebenen Raums ist äußerst niedrig,
und die Batterien sollten so schnell wie möglich
erneuert werden.
Verbindung zwischen MCs (E24) Die Funkverbindung der angegebenen Haup-
tregler ist unterbrochen.
Der Batterieladezustand in der Fernsteuerung
ist niedrig, und die Batterien sollten erneuert
werden.
36
VI.UH.M5.1C Produced by Danfoss Floor Heating Hydronics 08.2009
Vejledning CF-RC Fjernbetjening
VI.UH.M5.1C Fremstillet af Danfoss Floor Heating Hydronics 08.2009
37
DK
DK
Indhold
10. Figurer og illustrationer .......................................................A1-A2
1. Funktionsoversigt ........................................................................ 38
2. Installation .................................................................................... 39
3. Transmissionstest ........................................................................ 40
4. Montering ..................................................................................... 40
5. Menuer .......................................................................................... 41
5.1 Rum .................................................................................................................................41
5.2 Program .........................................................................................................................43
5.3 Opsætning ....................................................................................................................47
5.4 Alarmer ..........................................................................................................................49
6. Afinstallation ................................................................................ 50
7. Andre produkter til CF2-systemet og forkortelser .................... 51
8. Specifikationer .............................................................................. 51
9. Fejlfinding ..................................................................................... 52
38
Vejledning CF-RC Fjernbetjening
VI.UH.M5.1C Fremstillet af Danfoss Floor Heating Hydronics 08.2009
1. Funktionsoversigt
Forside – fig. 1
Display
Funktionstast 1
Funktionstast 2
Op/ned-knap
Venstre/højre-knap
Ikon for systemalarm
Ikon for kommunikation med masterregulator
Ikon for skift til 230V-strømkilde
Ikon for lav batteristand
Bemærk! Fjernbetjeningen har en selvforklarende menustruktur, og alle indstillinger udføres
nemt med op/ned- og venstre/højre-tasterne kombineret med funktionstasternes funktioner,
som vises over dem i displayet.
Bagside – fig. 2
Bagplade/dockingstation
Batterirum
Skruehul til vægmontering
Skrue og rawlplug
Transformer/strømstik
Bemærk! Fjern strippen, for at tilslutte de medfølgende batterier.
Vejledning CF-RC Fjernbetjening
VI.UH.M5.1C Fremstillet af Danfoss Floor Heating Hydronics 08.2009
39
DK
2. Installation
Bemærk!
Installer ernbetjeningen, efter du har installeret alle rumtermostaterne, se g. 5 b
Bemærk! Fjern strippen, for at tilslutte de medfølgende batterier.
Udfør tildelingen af ernbetjeningen til masterregulatoren inden for en afstand af 1½m
Når baggrundslyset i displayet er slukket, vil det første tastetryk kun aktivere dette lys
Aktiver tilstanden Install på masterregulatoren - fig. 3
Tryk på menuknappen for at vælge tilstanden Install. Installationsindikatoren
blinker
Aktiver tilstanden Install ved at trykke på OK . Installationsindikatoren tændes
Aktiver tilstanden Install på ernbetjeningen - fig. 1
Følg installationsguiden begyndende med valg af sprog, når batterierne er blevet
installeret
Efter installationsprocessen, indstilles tid og dato. Brug op/ned-knappen og ven-
stre/højre-knappen til at udføre indstillingerne. Bekræft indstillingerne med OK
aktiveret af funktionstast 1 ( )
Installationsprocessen afsluttes med en mulighed for at navngive de rum, hvori
rumtermostaterne bender sig. Dette gør adgang til og håndtering af systemet
meget nemt
Aktiver ændringsmenuen i menuen Navngiv rum med funktionstast 2 ( ) for at
ændre standardrumnavnene fra f.eks. MC1 udgang 1.2 (masterregulator 1, udgang 1
og 2) til Stuen, og bekræft med OK. Du kan også bruge menuen Stav til at oprette
andre navne end dem på listen
Når installationen er fuldført, vil opstartsskærmbilledet blive vist på displayet med
det faktiske tidspunkt og den faktiske dato øverst. Skærmen viser også den faktiske
temperatur i det første rum på rumlisten. Se afsnit 5.3 for at vælge et andet rum til
opstartsskærmen
Bemærk! Når en knap holdes nede under indstillingen, vil værdien ændres hurtigere
40
Vejledning CF-RC Fjernbetjening
VI.UH.M5.1C Fremstillet af Danfoss Floor Heating Hydronics 08.2009
3. Transmissionstest
Start en transmissionstest på ernbetjeningen
Fra opstartsskærmen aktiveres:
Menu
Opsætning
Linktest
Menuen Linktest for at aktivere en test af den trådløse transmission mellem
masterregulatoren og ernbetjeningen. Status for linktesten bliver vist, lige
efter testen er gennemført.
Hvis linktesten ikke lykkes:
• Prøv at ytte ernbetjeningen til et andet sted i rummet
Eller installer en repeater unit (CF-RU, se g. 5-c), og placer den mellem
masterregulatoren og ernbetjeningen
Bemærk! Linktesten kan tage nogle minutter, afhængig af systemets størrelse
4. Montering
Fjernbetjeningen er nu installeret – fig. 2
Når ernbetjeningen er blevet tildelt masterregulatoren (se afsnit 2), kan den
monteres på væggen ved hjælp af bagpladen/dockingstationen . Dette gør
det muligt at forbinde ernbetjeningen til en 230V-strømkilde ved hjælp af
den medfølgende transformer/strømstik . Når den ikke står i dockingstation-
en, får ernbetjeningen strøm fra to AA Alkaline 1,5V-batterier.
Vejledning CF-RC Fjernbetjening
VI.UH.M5.1C Fremstillet af Danfoss Floor Heating Hydronics 08.2009
41
DK
Kontroller transmissionen til masterregulatoren fra den ønskede placering
ved at udføre en linktest (se afsnit 3), før du placerer bagpladen/dockingsta-
tionen på væggen
Monter bagpladen/dockingstationen på væggen med skruer og
rawlplugs
Forbind dockingstationen til en 230V-strømkilde ved hjælp af transformeren/
strømstikket
• Sæt ernbetjeningen i dockingstationen
Bemærk! For at udvide senderækkevidden for CF2-systemet er det muligt at installere op til
tre repeater units i en kæde - se g. 4
5. Menuer
Bemærk! Når baggrundslyset i displayet er slukket, vil det første tastetryk kun aktivere dette lys.
5.1 Rum
Fra opstartsskærmen aktiveres:
Menu
Rum
Menuen Rum, hvorved en liste over alle systemets rum bliver vist. Vælg det
ønskede rum med OK for at få adgang til skærmbilledet for dette rum. Her kan
du se information om de indstillede og de faktiske temperaturer:
: Indikerer, at dette rum er en del af et igangværende tidsprogram
(se afsnit 5.2)
: Indikerer, at batteristanden for rumtermostaten er lav
: Indikerer, at den værdi, der er indstillet på rumtermostaten, over skrider
de min./maks.-værdier, der er indstillet på ernbetjeningen
42
Vejledning CF-RC Fjernbetjening
VI.UH.M5.1C Fremstillet af Danfoss Floor Heating Hydronics 08.2009
: Indikerer, at den indstillede temperatur er højere end den faktiske
temperatur
: Indikerer, at den indstillede temperatur er lavere end den fak tiske
temperatur
5.1.1 Muligheder
Fra skærmbilledet for rummet kan du aktivere menuen Muligheder med
adgang til adskillige rumindstillinger:
Indstil temperatur:
Her kan du indstille og låse den indstillede temperatur for rumtermostaten.
Låsning forhindrer justering af den indstillede temperatur på selve rumtermo-
staten.
Sæt min./maks.:
Her kan du indstille og låse minimum- og maksimumtemperaturer for
rumtermostaten. Låsning forhindrer justering ud over disse grænser på selve
rumtermostaten.
Ændre rumnavn:
Her kan du ændre rumnavne ved hjælp af en liste over mulige rumnavne, eller
du kan bruge menuen Stav... til at indtaste andre navne.
Indstil gulv min./maks.:
Her kan du indstille og låse minimum- og maksimumgulvoveradetemperaturer.*
Bemærk! Kun muligt med rumtermostat med infrarød gulvsensor, CF-RF
Setback:
Her kan du vælge at ignorere den næste eller igangværende setback-periode
(se afsnit 5.2.2).
Køling:
Her kan du deaktivere kølefunktionen for det pågældende rum*
Bemærk! Kun tilgængelig når masterregulatoren er i køletilstand
Vejledning CF-RC Fjernbetjening
VI.UH.M5.1C Fremstillet af Danfoss Floor Heating Hydronics 08.2009
43
DK
5.2 Program
Fra opstartsskærmen aktiveres:
Menu
Program
Menuen Program for at få adgang til de to tidsprogrammeringsmuligheder:
5.2.1 Ferieprogram:
Med dette program kan du indstille rumtemperaturen for alle rumtermosta-
ter, f.eks. i en ferie. Start- og slutdatoen for programmet indstilles nemt i en
kalender ved at bruge op/ned- og venstre/højre-tasterne (g. 1- / ) og
ved at bekræfte hver indstilling med OK. Rumtemperaturen og varigheden af
ferieprogrammet illustreres og aktiveres til sidst fra en detaljeret oversigt over
det oprettede program:
5.2.2 Zoneprogram:
I menuen Programmer zoneinddeling har du mulighed for at opdele de for-
skellige rum i op til seks forskellige zoner - hver zone med op til tre forskellige
tidsprogrammer for reduceret rumtemperatur på forskellige tider af døgnet.
44
Vejledning CF-RC Fjernbetjening
VI.UH.M5.1C Fremstillet af Danfoss Floor Heating Hydronics 08.2009
Muligheder:
Hver zone har et skærmbillede, der viser de rum, der hører ind under zonen.
Dette giver adgang til menuen Muligheder med funktionen Tilføj rum og tre
zoneprogrammer (op til).
Tilføj rum:
I denne menu efterfølges alle rummene af en ( ), der indikerer hvilken zone,
rummene hører til (se guren på næste side ). Som standard hører alle rum-
mene til Zone 1. Hvis der oprettes nye zoner, vil rummene blive yttet fra den
zone, de hører til, til den nye zone (fra zone 1 til zone 3 i guren).
Program 1 - 3:
Menuen Muligheder omfatter også tre mulige zoneprogrammer. Ved hjælp
af disse kan ugens syv dage inddeles i tre forskellige zoneprogrammer med
forskellige dage og tider for hvert program. Procedure for oprettelse eller æn-
dring af et program er den samme for alle de tre programmer:
Vejledning CF-RC Fjernbetjening
VI.UH.M5.1C Fremstillet af Danfoss Floor Heating Hydronics 08.2009
45
DK
Aktiver program (1- 3) fra menuen Muligheder med OK for at vælge dage for
dette program:
Vælg dage for programmet ved at ytte dem oven over den vandrette linje
med op/ned- og venstre/højreknapperne (g.: 1- / ). Bekræft med OK, og
aktiver næste trin for at vælge tidspunktet for sænkningsprogrammet.
Vælg tidspunkter for sænkningsprogrammet ved at indstille tidspunkterne for
de perioder, hvor du ønsker normal temperatur (angives af de sorte bjælker
oven over tidslinjen). Perioderne uden for de sorte bjælker er sænkning-
sperioder, hvorunder rumtemperaturen er reduceret. Du kan indstille start- og
sluttidspunkt med venstre/højreknappen, og skifte mellem tidspunkter via
op/nedknappen (g. 1- / ).
Du kan erne den anden periode
med normaltemperatur ved at
gøre dens sluttidspunkt identisk
med dens starttidspunkt:
46
Vejledning CF-RC Fjernbetjening
VI.UH.M5.1C Fremstillet af Danfoss Floor Heating Hydronics 08.2009
Du kan kalde den anden periode
med normaltemperatur , frem
igen med op/nedknappen og
ved at trykke dig igennem den
første periode .
Bekræft den valgte tidsperiode med OK for at aktivere det oprettede zone-
program fra denne oversigt:
Bemærk! De dage, der er valgt i programmet, er markeret med tydeligere begyndelses-
bogstaver
Annuller program:
Et oprettet program kan slettes ved hjælp af menuen Annuller program, der
fører frem til den samme oversigt som illustreret ovenfor.
Bemærk!
I menuen Muligheder, vil de oprettede programmer (1-3) være markeret med tydeligere
begyndelsesbogstaver
Vejledning CF-RC Fjernbetjening
VI.UH.M5.1C Fremstillet af Danfoss Floor Heating Hydronics 08.2009
47
DK
Hvis du ønsker at ignorere en sænknings periode i et rum, kan det ske ved hjælp af funk-
tionen Ignorer sænkning i menuen Muligheder for hvert rum (se afsnit 5.1.1)
Temperatur sænkning
Aktiver menuen Temperatur-sænkning i zoneprogrammet (se afsnit 5.2.2),
for at indstille rumtemperaturreduktionen til intervallet 1 til 10°C i sænknings
perioder.
5.3 Opsætning
Fra opstartsskærmen aktiveres:
Menu
Opsætning
Menuen Opsætning med adgang til masser af information og opsætningsmu-
ligheder for ernbetjeningen såvel som hele CF2-systemet.
Bemærk! Da nogle af opsætningsmulighederne i menuen Opsætning kan påvirke kongu-
ra tionen af CF2-systemet og dermed også hele apparatets funktion generelt, bør der
udvises forsigtighed i forbindelse med disse
Sprog:
Her kan du vælge et andet sprog end det, der blev valgt under installationen
(se afsnit 2).
Dato og tid:
Giver adgang til indstilling af dato og tid. Desuden indeholder denne menu
indstillingerne for og aktivering af sommertidsprogrammet. Dette gør det mu-
ligt for dig at kongurere hvilken dag, uge og måned, sommertiden begynder
og slutter.
48
Vejledning CF-RC Fjernbetjening
VI.UH.M5.1C Fremstillet af Danfoss Floor Heating Hydronics 08.2009
Alarm:
Fra denne menu kan du slå masterregulatorens (MC) akustiske alarm til/fra.
Lyden forekommer kun i tilfælde af alarm, som også indikeres af den røde
alarmdiode på masterregulatoren (se g. 3- ). I Alarm log kan du få specik
information om den fejl, der forårsagede alarmen, og tidspunktet for systemets
registrering af fejlen. Denne Alarm log gemmer de sidst forekomne alarmer
for, at du senere kan få adgang til dem og nemt kan identicere fejl i systemet.
Opstartsskærm:
Her kan du vælge hvilken rumtemperatur, du vil have vist på opstartsskærmen.
Service:
Her kan du indstille alle masterregulatorernes udgange (se g. 5 a) til enten et
gulv eller radiatorvarmesystem. Med gulvvarme kan du vælge On/O - eller
PWM- (Puls-pause) regulering. Hvis du vælger et radiatorsystem, indstilles
reguleringen automatisk til PWM. Selv et blandet system med gulvvarme i
nogle rum og radiatorer i andre kan vælges ved at indstille masterregulatorens
udgange individuelt for hvert rum til enten gulvvarme eller radiatorer.
Bemærk! Når masterregulatoren er sat til PWM, er cyklustiderne:
Gulvvarme: 2 timer
Radiatorvarme: 15 minutter.
I menuen Service aktiveres Standby temperatur-funktionen med OK for at
indstille en fast rumtemperatur for alle rumtermostaterne i intervallet 5 – 35°C,
når indgangen for globalt standby er aktiveret på masterregulatoren (se vej-
ledning til masterregulatoren, CF-MC for yderligere oplysninger).
Kontrast:
Her kan du justere kontrasten i ernbetjeningens display.
Linktest:
Aktiverer en linktest til masterregulatoren for at teste den trådløse transmis-
sion til og fra ernbetjeningen (se afsnit 3).
Vejledning CF-RC Fjernbetjening
VI.UH.M5.1C Fremstillet af Danfoss Floor Heating Hydronics 08.2009
49
DK
Identificer masterregulator:
Denne funktion gør det muligt for dig at identificere en specifik
masterregulator i et system med op til tre masterregulatorer. Alle udgangs-
lysdioder på den masterregulator, hvis identitet du ønsker at identicere, vil
blinke fra 1 til 10 og tilbage igen adskillige gange, når denne funktion aktiveres,
hvilket gør det nemt for dig at identicere den pågældende masterregulator.
5.4 Alarmer
Hvis der forekommer fejl i CF2-systemet, indikeres det af masterregulatoren og
direkte på ernbetjeningens display:
Når alarmen godkendes med OK, vil masterregulatorens buzzer slukkes (hvis
lyden er slået til, se afsnit 5.3), og CF2-systemet vil slå over på Alarmstatus
som vist på opstartsskærmen:
50
Vejledning CF-RC Fjernbetjening
VI.UH.M5.1C Fremstillet af Danfoss Floor Heating Hydronics 08.2009
Denne indikation af Alarm på ernbetjeningen og indikationen på master-
regulatoren vil fortsætte, indtil den fejl, der forårsagede alarmen, er blevet
afhjulpet.
Menuen Alarmer vil blive vist øverst på Menu-listen, der aktiveres fra opstarts-
skærmen:
Aktivering af menuen Alarmer med OK giver adgang til en Alarmstatus, hvor
du kan se en beskrivelse af den fejl, der forårsagede alarmen. Desuden kan du
vælge Alarm log for at få mere specik information om den fejl, der forårsa-
gede alarmen og tidspunktet for systemets registrering af fejlen. Denne Alarm
log gemmer de sidst forekomne alarmer for, at du senere kan få adgang til dem
og nemt kan nde fejlene i systemet. Når der ikke er nogen fejl, der forårsager en
alarm, kan du få adgang til Alarm log via menuen Opsætning (se afsnit 5.3).
6. Afinstallation
Nulstilling af ernbetjening, CF-RC - fig. 1:
Aktivér funktionstast 1 , funktionstast 2 og ned-knappen
samtidigt.
Fjernbetjeningen beder om din bekræftelse, før den nulstilles.
Hvis du bekræfter med Ja, nulstilles ernbetjeningen
Efter at du har nulstillet med Ja, er ernbetjeningen nu klar til på ny at blive
installeret til en masterregulator af typen CF-MC
Bemærk! Se venligts instruktionen for masterregulatoren, CF-MC for ere detaljer
Vejledning CF-RC Fjernbetjening
VI.UH.M5.1C Fremstillet af Danfoss Floor Heating Hydronics 08.2009
51
DK
7. Andre produkter til CF2-systemet og forkortelser
Andre produkter til CF2-systemet - fig. 5
a) Masterregulator, CF-MC: MC
b) Rumtermostat, CF-RS, -RD, -RP og –RF: Rumt.
c) Repeater unit, CF-RU: RU
8. Specifikationer
Kabellængde (netledning) 1,8m
Transmissionsfrekvens 868,42MHz
Transmissionsrækkevidde i bygninger (op til) 30m
Antal repeater units i en kæde (op til) 3
Transmissionseekt < 1mW
Forsyningsspænding 230V vekselstrøm
Omgivelsestemperatur 0-50°C
IP-klasse 21
52
Vejledning CF-RC Fjernbetjening
VI.UH.M5.1C Fremstillet af Danfoss Floor Heating Hydronics 08.2009
9. Fejlfinding
Fejlindikation Mulig årsag
Aktuator/udgang (E03) Udgangen på masterregulatoren (MC) eller
den aktuator, som er forbundet til denne
udgang, er kortsluttet eller afbrudt
Lav temperatur (E05) Temperaturen i rummet er under 5° C. (For-
søg at klarlægge, om rumtermostaten virker
ved at udføre en linktest fra den)
Link til masterregulator (E12) Rumtermostaten i det angivne rum har
mistet den trådløse forbindelse til master-
regulatoren (MC)
Lavt batteri for rumt. (E13) Batteristanden for rumtermostaten for
det angivne rum er lav, og batterierne bør
udskiftes
Kritisk lavt bat. for rumt. (E14) Batteristanden for rumtermostaten for det
angivne rum er kritisk lav, og batteriene bør
udskiftes så hurtigt som muligt
Link mellem MC’er (E24) De angivne masterregulatorer har mistet
deres trådløse forbindelse
Batteriniveauet for ernbetjeningen er lavt,
og batterierne bør udskiftes
Instruction Commande à distance CF-RC
VI.UH.M5.1C Produit par Danfoss Floor Heating Hydronics 08.2009
53
F
F
Index
10. Figures et illustrations .........................................................A1-A2
1. Présentation des fonctions .......................................................... 54
2. Installation .................................................................................... 54
3. Test de transmission ..................................................................... 56
4. Montage ........................................................................................ 56
5. Menus ............................................................................................ 57
5.1 Pièces ..............................................................................................................................57
5.2 Programme ..................................................................................................................59
5.3 Configuration ..............................................................................................................63
5.4 Alarmes ..........................................................................................................................65
6. Désinstallation ............................................................................ 66
7. Autres produits pour le système CF2 et abréviations ................ 67
8. Spécifications ................................................................................ 67
9. Dépannage .................................................................................... 68
54
Instruction Commande à distance CF-RC
VI.UH.M5.1C Produit par Danfoss Floor Heating Hydronics 08.2009
1. Présentation des fonctions
Avant – fig. 1
Affichage
Touche programmable 1
Touche programmable 2
Sélecteur haut/bas
Sélecteur gauche/droite
Icône pour système d’alarme
Icône pour communication avec le Régulateur principal
Icône pour interrupteur alimentation électrique 230V
Icône pour niveau de piles bas
Note: La commande à distance est conçue avec une structure de menu autoguidée, an
de rendre tous les réglages faciles à exécuter par les sélecteurs haut/bas et gauche/droite,
combinés avec les fonctions des touches programmables, comme illustré sur l’achage
juste au-dessus de celles-ci.
Arrière – fig. 2
Plaque arrière/station d’ancrage
Compartiment batterie
Orice vis pour montage mural
Vis et cheville murale
Fiche alimentation électrique/transformateur
Note: Retirer la bande pour connecter les piles jointes.
2. Installation
Note:
Installer la commande à distance après installation de tous les thermostats d’ambiance,
voir g. 5-b
Retirer la bande avant d’installer les piles jointes
Instruction Commande à distance CF-RC
VI.UH.M5.1C Produit par Danfoss Floor Heating Hydronics 08.2009
55
F
Laectation de la commande à distance au Régulateur principal doit se faire à une dis-
tance de 1½m au maximum
Lorsque le rétroéclairage de l’achage est éteint, la première activation d’un bouton va
seulement activer cet éclairage
Activer le mode Installation sur le Régulateur principal - fig. 3
Utiliser le bouton de sélection menu pour sélectionner le mode Installa-
tion. La diode LED installation clignote
Activer le mode Installation en appuyant sur OK . La diode LED installation
s’allume
Activer le mode Installation sur la commande à distance - fig. 1
Lorsque les piles ont été installées, suivre le guide d’installation en commen-
çant par la sélection de la langue
Après la procédure d’installation, régler l’heure et la date. Utiliser le sélecteur
haut/bas et le sélecteur gauche/droite pour faire ces réglages. Approu-
ver les réglages en activant OK avec la touche programmable 1 ( )
Linstallation se termine par la possibilité d’attribuer un nom aux pièces dans
lesquelles les thermostats d’ambiance sont placés. Ceci permet un accès et
une utilisation ultérieure du système plus aisés
Dans le menu Nom pièces, activer le menu changer avec la touche pro-
grammable 2 ( ) pour changer les noms de pièce par dé faut, depuis par ex.
la sortie 1.2 MC1 (sortie 1 et 2 Régulateur principal 1) pour salle de séjour et
approuver avec OK. Vous pouvez aussi utili ser le menu écrire…. pour com-
poser d’autres noms que ceux figurant sur la liste
Lorsque l’installation est terminée, l’écran de démarrage sera aché avec
l’heure et la date eectives tout en haut. Lécran ache également la tem-
pérature eective de la première pièce de la liste des pièces. Voir 5.3 pour
sélectionner une autre pièce pour l’écran de démarrage
Note: Le mainten d’un bouton activé durant les réglages va permettre un changement des
valeurs plus rapide
56
Instruction Commande à distance CF-RC
VI.UH.M5.1C Produit par Danfoss Floor Heating Hydronics 08.2009
3. Test de transmission
Initialiser un test de transmission sur la commande à distance
Depuis l’écran de démarrage, activer le:
Menu
Réglage
Test connexion
Menu Test connexion pour activer un test de transmission sans fil entre le
Régulateur principal et la commande à distance. Létat du test de connexion
sera aché immédiatement après la n du test.
Si le test nest pas réussi:
• Essayer de déplacer la commande à distance dans la pièce
Ou installer un réémetteur (CF-RU, voir g. 5-c) et le placer entre le Régula-
teur principal et la commande à distance
Note: Le test peut prendre quelques minutes, selon la grandeur du système
4. Montage
La commande à distance a été installée – fig. 2
Lorsque la commande à distance a été attribuée au Régulateur principal (voir
2), elle peut être montée sur la paroi avec la plaque arrière / la station d’ancra-
ge . Cela permet de connecter la commande à distance à une alimentation
électrique 230V par le transformateur / la che d’alimentation électrique four-
nis . Lorsquelle n’est pas dans la station d’ancrage, la commande à distance
est alimentée par deux piles 1,5V alcalines AA
Instruction Commande à distance CF-RC
VI.UH.M5.1C Produit par Danfoss Floor Heating Hydronics 08.2009
57
F
Avant de placer la plaque arrière / la station d’ancrage sur la paroi, vérier la
transmission avec le Régulateur principal à partir de l’emplacement désiré, en
faisant un test de connexion (voir 3)
Monter la plaque arrière / la station d’ancrage sur la paroi au moyen de vis et
des chevilles murales
Connecter la station d’ancrage à une sortie d’alimentation électrique 230V,
par le transformateur / la che d’alimentation électrique
• Placer la commande à distance dans la station d’ancrage
Note: Pour augmenter la portée de transmission du système CF2, jusqu’à trois réémetteurs
peuvent être installés en chaîne – voir g. 4
5. Menus
Note: Lorsque le rétroéclairage est éteint, la première pression d’un bouton va seulement
activer cet éclairage.
5.1 Pièces
Depuis l’écran de démarrage, activer le:
Menu
Pièces
menu Pièces pour accéder à une liste de toutes les pièces du système. Sé-
lectionner la pièce désirée avec OK et entrer sur l’écran de cette pièce. Vous
pouvez consulter ici les informations relatives aux températures xées et aux
températures eectives:
: Indique que cette pièce est comprise dans un programme de tempo-
risation en cours (voir 5.2)
: Indique que la piles du thermostat d’ambiance est faible
58
Instruction Commande à distance CF-RC
VI.UH.M5.1C Produit par Danfoss Floor Heating Hydronics 08.2009
: Indique que la valeur xée par le thermostat d’ambiance est au-delà
des limites min./max. xées sur la commande à distance.
: Indique que la température xée est au-dessus de la tem pérature
eective
: Indique que la température xée est au-dessous de la tem pérature
eective
5.1.1 Options
A partir de lécran Pièce, il est possible d’activer un menu Options avec accès à
plusieurs options pièce:
Température réglée:
Vous pouvez ici xer et verrouiller la température réglée pour le thermostat
d’ambiance. Le verrouillage empêche la modication de la température réglée
sur le thermostat d’ambiance.
Min/max réglé:
Ici vous pouvez régler et verrouiller les températures maximales et minimales
du thermostat d’ambiance. Le verrouillage empêche la modication au-delà
de ces limites sur le thermostat d’ambiance.
Changer nom pièce:
Vous pouvez ici changer le nom de la pièce au moyen d’une liste des noms de
pièces possibles ou vous pouvez utiliser le menu écrire..... pour créer d’autres
noms.
Min/max sol réglé:
Ici vous pouvez régler et verrouiller les températures maximales et minimales
de température de surface au sol.
Note: Seulement disponible sur le thermostat d’ambiance avec capteur au sol infrarouge, CF-RF
Valeur de consigne:
Possibilité de remplacer ici la valeur de consigne en cours ou suivante période
(voir 5.2.2)
Instruction Commande à distance CF-RC
VI.UH.M5.1C Produit par Danfoss Floor Heating Hydronics 08.2009
59
F
Refroidissement:
Vous pouvez ici désactiver la fonction de refroidissement pour la pièce en
question
Note: Seulement disponible lorsque le Régulateur principal est en mode Refroidissement
5.2 Programme
Depuis l’écran de démarrage, activer le:
Menu
Programme
Menu Programme pour consulter les deux options programme de temporisation:
5.2.1 Programme vacances:
Avec ce programme, vous pouvez régler la température ambiante pour tous
les thermostats d’ambiance durant les vacances, par exemple.
La date de début et de n du programme est facilement réglée sur un calen-
drier en utilisant les sélecteurs haut/bas et gauche/droite (g. - / ) et en
approuvant chaque réglage avec OK. La température ambiante et la durée
du programme de la période sont illustrés et  nalement activés à partir d’un
relevé détaillé pour le programme créé:
60
Instruction Commande à distance CF-RC
VI.UH.M5.1C Produit par Danfoss Floor Heating Hydronics 08.2009
5.2.2 Programme hebdomadaire:
Dans le menu Programme hebdomadaire vous avez la possibilité de subdi-
viser les diérentes pièces, jusqu’à six diérentes zones - chaque zone avec
jusqu’à trois programmes journalier diérents.
Options:
Chaque zone possède un écran montrant les pièces comprises dans la zone.
Ceci donne accès à un menu Options avec une fonction Ajouter pièce et trois
programmes journaliers (jusqu’à).
Ajouter pièce:
Dans ce menu, toutes les pièces sont suivies d’une ( ) indiquant à quelle zone
chaque pièce a été attribuée (voir gure ci-dessous ). Par défaut, toutes les
pièces sont attribuées à la zone 1. Si de nouvelles zones sont créées, les pièces
seront déplacées depuis la zone à laquelle elles sont attribuées, vers la nou-
velle zone (depuis la zone 1 vers la zone 3 dans la gure ci-dessous).
Programme 1 - 3:
Le menu Options comprend également trois programmes journaliers possi-
bles pour chaque zone. Ainsi , on peut aecter à chaque jour un programme
journalier particulier (parmi 3). La procédure pour la création ou la modica-
tion d’un programme est la même pour chacun des trois programmes:
Activer le programme (1- 3) à partir du menu Options avec OK pour sélec-
tionner les jours pour ce programme:
Instruction Commande à distance CF-RC
VI.UH.M5.1C Produit par Danfoss Floor Heating Hydronics 08.2009
61
F
Utiliser les sélecteurs haut/bas et gauche/droite (g. 1- / ) pour sélection-
ner les jours pour ce programme, ceci en les déplaçant au-dessus de la ligne
horizontale. Conrmer avec OK et activer l’étape suivante pour sélectionner les
périodes de chauage.
Régler les programmes de température , les barres noires au-dessus de la
ligne des heures indiquent les périodes de confort (en dehors de ces barres
noires , la température est réduite). Régler l’heure de début et de n avec le
sélecteur gauche/droite et basculer entre les périodes en utilisant le sélecteur
haut/bas (g. 1- / ).
Vous pouvez éliminer la deux-
ième période, en modiant
l’heure de n de cette période
en son heure de début :
62
Instruction Commande à distance CF-RC
VI.UH.M5.1C Produit par Danfoss Floor Heating Hydronics 08.2009
La seconde période, avec la
température de pièce normale
, peut être à nouveau ajoutée
au moyen du sélecteur haut/
bas et en basculant à travers de
la première période .
Conrmer les périodes sélectionnées avec OK pour activer le programme
valeur de consigne créé à partir de ce relevé :
Note: Les jours sélectionnés dans ce programme sont indiqués par des majuscules plus distinctes
Annuler programme:
Un programme créé peut être eacé par le menu Annuler Programme
conduisant au même relevé selon illustration ci-dessus.
Note:
Dans le menu Options les prgrammes créés (1-3) seront indiqués avec des majuscules plus
distinctes
Si vous désirez remplacer programme dans une pièce, vous pouvez le faire par la fonction
Remplacer programme dans le menu Options de chaque pièce (voir 5.1.1)
Instruction Commande à distance CF-RC
VI.UH.M5.1C Produit par Danfoss Floor Heating Hydronics 08.2009
63
F
5.3 Configuration
Depuis l’écran de démarrage, activer le:
Menu
Configuration
Menu Configuration avec accès à toute une série d’informations et de possibi-
lités de réglage de la commande à distance ainsi que de tout le système CF2.
Note: Etant donné que certaines possibilités de réglage du menu Configuration peuvent
aecter la conguration du système CF2 et ainsi le fonctionnement de toute l’application
en général, celui-ci doit utilisé avec précautions
Langues:
Vous pouvez choisir ici une autre langue que celle sélectionnée lors de la
procédure d’installation (voir 2).
Date et heure:
Donne accès au réglage de l’heure et de la date. Ce menu comprend en outre
les réglages pour le programme heure d’été et pour son activation. Cela permet
de congurer le jour, la semaine et le mois du début et de la n de l’heure d’été.
Abaissement de température
Dans le programme hebdomadaire (voir 5.2.2), activer le menu Abaisse-
ment de température pour régler la diminution de température de 1 à 10°C
durant les périodes de chauage réduit.
Alarme:
A partir de ce menu, vous pouvez activer l’alarme sonore du Régulateur
principal (MC) Arrêt/Marche. Le son est activé uniquement en cas d’alarme,
indiquée également par une diode LED d’alarme rouge sur le Régulateur
principal (voir g. 3- ). Dans le Journal alarme, vous pouvez obtenir des
64
Instruction Commande à distance CF-RC
VI.UH.M5.1C Produit par Danfoss Floor Heating Hydronics 08.2009
information spéciques au sujet de l’erreur causant l’alarme et l’heure de son
enregistrement par le système. Ce Journal alarme sauvegarde les dernières
alarmes survenues pour le dernier accès et facilite l’identication des défaillan-
ces du système.
Ecran de démarrage:
Vous pouvez choisir ici quelle température de pièce vous désirez voir achée
sur l’écran de démarrage.
Service:
Vous pouvez congurer ici toutes les sorties du Régulateur principal (voir g.
5-a) pour un système de chauage au sol ou par radiateurs. Avec le chauage
au sol, vous pouvez choisir un mode Tout ou Rien ou chrono-proportionnel -
modulation d’impulsions en largeur). En sélectionnant un sytème radiateurs, la
régulation est mise automatiquement sur PWM. Même un système mixte, avec
chauage au sol et radiateurs dans des pièces séparées, peut être sélectionné
en réglant les sorties sur le Régulateur principal individuellement pour chaque
pièce pour le chauage au sol ou par radiateurs.
Note: Lorsque le Régulateur principal est régulé par Chrono, les durées de cycles sont :
Chauffage au sol: 2 heures
Chauage radiateurs: 15 minutes.
Dans le menu Service, activer la fonction Température de veille avec OK an de
pouvoir régler une température ambiante xe pour tous les thermostats d’am-
biance à 5 – 35°C lorsque l’entrée veille globale est activée sur le Régulateur prin-
cipal (voir instructions pour le Régulateur principal, CF-MC pour plus de détails)
Contraste:
Vous pouvez régler ici le contraste pour l’achage de la commande à distance.
Test de connexion:
Active un test de connexion au Régulateur principal, pour tester la transmis-
sion sans l vers et de la commande à distance (voir 3).
Instruction Commande à distance CF-RC
VI.UH.M5.1C Produit par Danfoss Floor Heating Hydronics 08.2009
65
F
Identifier le Régulateur principal:
Cette fonction vous permet d’identier un Régulateur principal spécique
dans un système allant jusqu’à trois Régulateurs principaux. Lorsque cette
fonction est activée, le Régulateur principal dont vous désirez révéler l’identité
va clignoter de toutes ses diodes LED de sortie de 1 à 10 et retour plusieurs
fois, pour une identication facile.
5.4 Alarmes
Si une erreur se produit dans le système CF2, elle est indiquée par le Régula-
teur principal et directement sur l’achage de la commande à distance:
Lorsque l’alarme a fait l’objet d’un accusé de réception par OK, l’alarme sonore
du Régulateur principal va s’arrêter (si le son est sur Marche, voir 5.3) et le système
CF2 va commuter sur Etat alarme comme indiqué sur l’écran de démarrage:
66
Instruction Commande à distance CF-RC
VI.UH.M5.1C Produit par Danfoss Floor Heating Hydronics 08.2009
Cette indication d’Alarme sur la commande à distance et l’indication sur le
Régulateur principal vont persister jusqu’à ce que la cause de l’erreur soit
éliminée.
Un menu Alarmes va être aché en tête de la liste Menu activée à partir de
l’écran démarrage:
L’acitvation de ce menu Alarmes avec OK permet un accès à un Etat alarme
où vous pouvez voir une description de lerreur à l’origine de l’alarme. En outre,
vous pouvez sélectionner le Journal alarme pour obtenir des informations
spéciques concernant l’erreur à l’origine de l’alarme et l’heure de son enregis-
tement par le système. Ce Journal alarme sauvegarde les dernières alarmes
survenues pour le dernier accès et facilite l’identication des défaillances du
système. Lorsqu’une alarme est causée par aucune erreur, vous pouvez accé-
der au Journal alarme par le menu Configuration (voir 5.3).
6. Désinstallation
Réinitialiser la Commande à distance, CF-RC - fig. 1:
Activer en même temps la touche programmable 1 , la touche program-
mable 2 et le sélecteur bas .
La Commande à distance nécessite une conrmation avant réinitiali sation.
La conrmation avec oui réinitialise la Commande à distance .
Instruction Commande à distance CF-RC
VI.UH.M5.1C Produit par Danfoss Floor Heating Hydronics 08.2009
67
F
Par la conrmation de la réinitialisation par oui”, la Commande à distance est
maintenant prête pour linstallation à un Régulateur principal, CF-MC
Note: Veuillez consulter le manuel du régulateur principal pour de plus amples détails.
7. Autres produits pour le système CF2 et abréviations
Autres produits pour le système CF2 - fig. 5
MC: a) Régulateur principal, CF-MC
T. d’ambiance: b) Thermostat d’ambiance, CF-RS, -RD, -RP et –RF
RU: c) Réémetteur, CF-RU
8. Spécifications
Longueur câble (alimentation électrique) 1,8m.
Fréquence transmission 868,42MHz.
Portée transmission dans des immeubles (jusqu’à) 30m.
Nombre de réémetteurs dans une chaîne (jusqu’à) 3
Puissance transmission < 1mW
Tension alimentation 230V courant alternatif
Température ambiante 0-50°C
Classe IP 21
68
Instruction Commande à distance CF-RC
VI.UH.M5.1C Produit par Danfoss Floor Heating Hydronics 08.2009
9. Dépannage
Indication erreur Causes possibles
Actionneur / sortie (E03) La sortie du Régulateur principal (MC) ou du réémetteur
connecté à cette sortie est court-circuité ou déconnecté.
Température faible (E05) La température de la pièce est inférieure à 5°C. (Essayer
de vérier la fonction du thermostat d’ambiance en
faisant un test de connexion à partir de celui-ci)
Connexion au Régula-
teur principal (E12)
Le thermostat d’ambiance dans la pièce indiquée n’a
plus de connexion sans l au Régulateur principal (MC)
Piles faibles dans T.
d’ambiance (E13)
Bas niveau de piles du thermostat d’ambiance pour la
pièce indiquée et les piles doivent être remplacées
Piles très faibles dans T.
d’ambiance (E14)
Niveau de piles du thermostat d’ambiance pour la pièce
indiquée est très bas et les piles doivent être remplacées
le plus rapidement possible
Connexion entre les MC
(Régulateurs principaux)
(E24)
Les Régulateurs principaux nont plus de connexion
sans fil
Bas niveau de piles de la commande à distance et les
piles doivent être remplacées
Bruksanvisning CF-RC Fjärrkontroll
VI.UH.M5.1C Tillverkad av Danfoss Floor Heating Hydronics 08.2009
69
SE
SE
Innehållsförteckning
10. Bilder och illustrationer ....................................................... A1-A2
1. Funktionsöversikt ......................................................................... 70
2. Installation .................................................................................... 71
3. Kommunikationstest .................................................................... 72
4. Montering ..................................................................................... 72
5. Menyer ........................................................................................... 73
5.1 Rum .................................................................................................................................73
5.2 Program .........................................................................................................................75
5.3 Inställning .....................................................................................................................79
5.4 Larm ................................................................................................................................81
6. Avinstallation ................................................................................ 82
7. Andra produkter till CF2-systemet och förkortningar .............. 83
8. Specifikationer .............................................................................. 83
9. Felsökning ..................................................................................... 84
70
Bruksanvisning CF-RC Fjärrkontroll
VI.UH.M5.1C Tillverkad av Danfoss Floor Heating Hydronics 08.2009
1. Funktionsöversikt
Framsida – bild 1
Display
Funktionsknapp 1
Funktionsknapp 2
Upp/ner-knapp
Vänster/höger-knapp
Ikon för systemlarm
Ikon för kommunikation med masterregulator
Ikon för skifte till 230 V strömkälla
Ikon för svagt batteri
Observera! Fjärrkontrollen har en självförklarande menystruktur och alla inställningar
utförs enkelt med upp/ner- och vänster/höger-knapparna kombinerat med funktionsknap-
parnas funktioner som visas över dem i displayen.
Baksida – bild 2
Bakpanel/dockningsstation
Batterifack
Skruvhål för väggmontering
Skruvar och rawlplugg
Transformator/stickkontakt
Observera! Ta bort bandet för anslutning av de medföljande batterierna.
Bruksanvisning CF-RC Fjärrkontroll
VI.UH.M5.1C Tillverkad av Danfoss Floor Heating Hydronics 08.2009
71
SE
2. Installation
Observera!
Installera ärrkontrollen efter att du installerat alla rumstermostaterna, se bild 5-b
Observera! Ta bort bandet för anslutning av de medföljande batterierna.
Utför tilldelningen av ärrkontrollen till masterregulatorn på ett avstånd av 1½m
När bakgrundsljuset i displayen är släckt kommer den första knapptryckningen bara att
aktivera denna lampa
Aktivera läget Install på masterregulatorn - bild 3
Tryck på menyknappen för att välja läget Install. Installationsindikatorn
blinkar
Aktivera läget Install genom att trycka på OK . Installationsindikatorn tänds
Aktivera läget Install på ärrkontrollen - bild 1
Följ installationsguiden genom att börja med val av språk, när batterierna har
installerats
Efter installationsprocessen ställer man in tid och datum. Tryck på upp/ner-
knappen och vänster/höger-knappen för att utföra inställningarna.
Bekräfta inställningarna med OK aktiverat med funktionstangent 1 ( )
Installationsprocessen avslutas med möjlighet att namnge de rum där rum-
stermostaterna benner sig. Detta gör tillgång till och hantering av systemet
mycket enkelt
Aktivera ändringsmenyn i menyn Namnge rum med funktionstangent 2 ( )
för att ändra standardrumsnamnen från t.ex. MC1 utgång 1.2 (masterregulator
1, utgång 1 och 2) till rummet och bekräfta med OK. Du kan också använda
menyn Skriv för att skriva andra namn än de i listan
När installationen är genomförd kommer startskärmbilden att visas på dis-
playen med den faktiska tidpunkten och det faktiska datumet överst. Skär-
men visar också den faktiska temperaturen i det första rummet i rumslistan.
Se avsnitt 5.3 för att välja ett annat rum till startskärmen
Observera! När en knapp hålls ner under inställningen kommer värdet att ändras snabbare
72
Bruksanvisning CF-RC Fjärrkontroll
VI.UH.M5.1C Tillverkad av Danfoss Floor Heating Hydronics 08.2009
3. Kommunikationstest
Starta ett kommunikationstest på ärrkontrollen
Från startskärmen aktiveras:
Meny
Inställning
Linktest
Menyn Linktest för att aktivera ett test av den trådlösa kommunikationen
mellan masterregulatorn och ärrkontrollen. Status för linktestet visas efter att
testet genomförts.
Om linktestet inte lyckas:
• Försök att ytta ärrkontrollen till en annan plats i rummet
Eller installera en repeaterenhet (CF-RU, se bild 5-c), och placera den mellan
masterregulatorn och ärrkontrollen
Observera! Linktestet kan ta några minuter, beroende på systemets storlek
4. Montering
Fjärrkontrollen är nu installerad – bild 2
När ärrkontrollen tilldelats masterregulatorn (se avsnitt 2), kan den monteras
på väggen med hjälp av bakpanelen/dockningsstationen . Detta gör det
möjligt att ansluta ärrkontrollen till en 230 V strömkälla med hjälp av den
medföljande transformatorn/stickkontakten . När den inte står i docknings-
stationen får ärrkontrollen ström från två AA alkaliska 1,5 V-batterier.
Bruksanvisning CF-RC Fjärrkontroll
VI.UH.M5.1C Tillverkad av Danfoss Floor Heating Hydronics 08.2009
73
SE
Veriera kommunikationen till masterregulatorn från den önskade placerin-
gen genom att utföra ett linktest (se avsnitt 3) innan du placerar bakpanelen/
dockningsstationen på väggen
• Montera bakpanelen/dockningsstationen på väggen med skruvar och
rawlpluggar
Anslut dockningsstationen till en 230 V strömkälla med hjälp av transforma-
torn/stickkontakten
• Ställ ärrkontrollen i dockningsstationen
Observera! För att utvidga kommunikationsräckvidden för CF2-systemet är det möjligt att
installera upp till tre repeaterenheter i en kedja - se bild 4
5. Menyer
Observera! När bakgrundsbelysningen i displayen är släckt kommer den första knapptryck-
ningen bara att aktivera denna lampa.
5.1 Rum
Från startskärmen aktiveras:
Meny
Rum
Menyn Rum, varefter en lista över alla systemets rum visas. Välj det önskade
rummet med OK för att få tillgång till skärmbilden för detta rum. Här kan du se
information om de inställda och faktiska temperaturerna:
: Indikerar att detta rum är en del av ett igångvarande tidsprogram
(se avsnitt 5.2)
: Indikerar att batterinivån för rumstermostaten är låg
: Indikerar att det värde som är installerat på rumstermostaten överskri-
der de min/max-värden som är inställda på ärrkontrollen
74
Bruksanvisning CF-RC Fjärrkontroll
VI.UH.M5.1C Tillverkad av Danfoss Floor Heating Hydronics 08.2009
: Indikerar att den inställda temperaturen är högre än den faktiska
temperaturen
: Indikerar att den inställda temperaturen är lägre än den faktiska
temperaturen
5.1.1 Alternativ
Från skärmbilden för rummet kan du aktivera menyn Alternativ med tillgång
till ett ertal rumsinställningar:
Ställ in temperatur:
Här kan du ställa in och låsa den inställda temperaturen för rumstermostaten.
Låsning förhindrar justering av den inställda temperaturen på rumstermostaten.
Ställ in min/max:
Här kan du ställa in och låsa minsta och högsta temperatur för rumstermostaten.
Låsning förhindrar justering förbi dessa gränser på rumstermostaten.
Ändra rumsnamn:
Här kan du ändra rumsnamnen med hjälp av en lista över möjliga rumsnamn,
eller så kan du använda menyn Skriv... för att skriva in andra namn.
Ställ in min/max för golv:
Här kan du ställa in och låsa minsta och högsta yttemperatur för golv.
Observera! Bara möjligt med rumstermostat med infraröd golvsensor, CF-RF
Spartemperatur:
Här kan du välja att ignorera nästa eller igångvarande sparperiod (se avsnitt 5.2.2).
Kylning:
Här kan du avaktivera kylningsfunktionen för det aktuella rummet
Observera! Bara tillgänglig när masterregulatorn är i kylningsläge
Bruksanvisning CF-RC Fjärrkontroll
VI.UH.M5.1C Tillverkad av Danfoss Floor Heating Hydronics 08.2009
75
SE
5.2 Program
Från startskärmen aktiveras:
Meny
Program
Menyn Program för att få tillgång till de två tidsprogrammeringsmöjligheterna:
5.2.1 Semesterprogram:
Med detta program kan du ställa in rumstemperaturen för alla rums-termo-
stater, t.ex. under en semester. Start- och slutdatum för programmet ställs in
enkelt i en kalender genom att använda upp/ner- och vänster/höger-knappar-
na (bild 1- / ) och genom att bekräfta varje inställning med OK. Rumstem-
peraturen och varaktigheter för periodprogrammet illustreras och aktiveras till
sist från en detaljerad översikt över det inställda programmet:
5.2.2 Sparprogram:
I menyn Programmera zoner har du möjlighet att dela upp de olika rummen
i upp till sex olika zoner - varje zon med upp till tre olika sparprogram för redu-
cerad rumstemperatur på olika tider på dygnet.
76
Bruksanvisning CF-RC Fjärrkontroll
VI.UH.M5.1C Tillverkad av Danfoss Floor Heating Hydronics 08.2009
Alternativ:
Varje zon har en skärmbild som visar de rum som hör till den zonen. Detta ger
tillgång till menyn Alternativ med funktionen Lägg till rum och tre Sparpro-
gram (upp till).
Lägg till rum:
I denna meny efterföljs alla rummen av en ( ), som indikerar vilken zon rum-
men hör till (se bilden nedan ). Som standard tillhör alla rummen Zon 1. Om
det ställs in nya zoner, kommer rummen att yttas från den zon de tillhör till
den nya zonen (från zon 1 till zon 3 i bilden nedan).
Program 1 - 3:
Menyn Alternativ omfattar också tre möjliga sparprogram för varje zon.
Med hjälp av dem kan veckans sju dagar delas in i tre olika sparprogram med
olika dagar och sparperioder för varje program. Procedur för inställning eller
ändring av ett program är densamma för alla tre program:
Bruksanvisning CF-RC Fjärrkontroll
VI.UH.M5.1C Tillverkad av Danfoss Floor Heating Hydronics 08.2009
77
SE
Aktivera program (1- 3) från menyn Alternativ med OK för att välja dag för
detta program:
Välj dag för programmet genom att ytta dem över den horisontella linjen med
upp/ner- och vänster/höger-knapparna (bild: 1- / ). Bekräfta med OK och
aktivera nästa steg för att välja vid vilken tidpunkt sparprogrammet ska starta.
Välj tidpunkter för sparprogrammet genom att ställa in tidpunkterna för de
perioder där du önskar normal temperatur (anges med de svarta strecken
över tidslinjen). Perioderna utanför de svarta strecken är sparperioder då
rumstemperaturen är reducerad. Du kan ställa in start- och sluttidpunkt med
vänster/höger-knappen och skifta mellan tidpunkterna via upp/ner-knappen
(bild 1- / ).
Du kan radera den andra peri-
oden med normal temperatur
genom att göra sluttidpunkten
identisk med starttidpunkten:
78
Bruksanvisning CF-RC Fjärrkontroll
VI.UH.M5.1C Tillverkad av Danfoss Floor Heating Hydronics 08.2009
Du kan hämta den andra peri-
oden med normal temperatur
, igen med upp/ner-knap-
pen och genom att trycka dig
igenom den första perioden .
Bekräfta den valda tidsperioden med OK för att aktivera det inställda sparpro-
grammet från denna översikt:
Observera! De dagar som är valda i programmet är markerade med tydliga begynnelse-
bokstäver
Ta bort program:
Ett inställt program kan raderas med hjälp av menyn Ta bort program, som
leder fram till samma översikt som visas ovan.
Observera!
I menyn Alternativ, kommer de inställda programmen (1-3) att vara markerade med
tydliga begynnelsebokstäver
Om du önskar ignorera en sparperiod i ett rum, kan du göra det med hjälp av funktionen
Ignorera sänkning i menyn Alternativ för varje rum (se avsnitt 5.1.1)
Bruksanvisning CF-RC Fjärrkontroll
VI.UH.M5.1C Tillverkad av Danfoss Floor Heating Hydronics 08.2009
79
SE
Temperatursänkning:
Aktivera menyn Temperatursänkning i Sparprogram (se avsnitt 5.2.2), för att
ställa in rumstemperaturminskningen till 1 - 10°C i sparperioder.
5.3 Inställning
Från startskärmen aktiveras:
Meny
Inställning
Menyn Inställning med tillgång till mängder av information och
installationsmöjligheter för ärrkontrollen såväl som hela CF2-systemet.
Observera! Eftersom några av inställningsmöjligheterna i menyn Inställning kan påverka
kongurationen av CF2-systemet och därmed också hela apparatens allmänna funktion
bör man iaktta försiktighet i förbindelse med dem
Språk:
Här kan du välja ett annat språk än det som valdes under installationen (se
avsnitt 2).
Datum och tid:
Ger tillgång till inställning av datum och tid. Dessutom innehåller denna meny
inställningar för och aktivering av sommartidsprogrammet. Detta gör det möj-
ligt för dig att kongurera vilken dag, vecka och månad sommartiden börjar
och slutar.
Larm:
Från denna meny kan du aktivera och avaktivera masterregulatorns (MC) aku-
stiska larm. Ljudet förekommer bara i händelse av larm som också indikeras
av den röda larmlampan på masterregulatorn (se bild 3- ). I larmet kan du
få specik information om det fel som förorsakade larmet och tidpunkten när
80
Bruksanvisning CF-RC Fjärrkontroll
VI.UH.M5.1C Tillverkad av Danfoss Floor Heating Hydronics 08.2009
systemet registrerade felet. Denna Larmlogg sparar de senaste larmen så att
du senare kan få tillgång till dem och enkelt kan identiera fel i systemet.
Startskärm:
Här kan du välja vilken rumstemperatur du vill visa på startskärmen.
Service:
Här kan du kongurera alla masterregulatorns utgångar (se bild 5 a) till
antingen ett golv- eller radiatorvärmesystem. Med golvvärme kan du välja
tvåpunkts- eller PWM-reglering (pulspaus).
Om du väljer ett radiatorsystem ställs regleringen automatiskt till PWM. Du
kan välja ett blandat system med golvvärme i några rum och radiatorer i andra
genom att ställa in masterregulatorns utgångar individuellt för varje rum till
antingen golvvärme eller radiatorer.
Observera! När masterregulatorn är satt till PWM är cykeltiderna:
Golvvärme: Två timmar
Radiatorer: 15 minuter.
I menyn Service aktiveras Standbytemperatur-funktionen med OK för att
ställa in en fast rumstemperatur för alla rumstermostater till 5 – 35°C, när ing-
ången för överstyrning är aktiverad på masterregulatorn (se bruksanvisning
för masterregulatorn, CF-MC för ytterligare information).
Kontrast:
Här kan du justera kontrasten i ärrkontrollens display.
Linktest:
Aktiverar ett linktest till masterregulatorn för att testa den trådlösa kommuni-
kationen till och från ärrkontrollen (se avsnitt 3).
Identifiera masterregulator:
Denna funktion gör det möjligt för dig att identiera en specik masterregula-
tor i ett system med upp till tre masterregulatorer. Alla utgångslampor på den
Bruksanvisning CF-RC Fjärrkontroll
VI.UH.M5.1C Tillverkad av Danfoss Floor Heating Hydronics 08.2009
81
SE
masterregulator vars identitet du önskar identiera kommer att blinka från 1
till 10 och tillbaka igen åtskilliga gånger när denna funktion aktiveras vilket
gör det enkelt för dig att identiera den aktuella masterregulatorn.
5.4 Larm
Om det förekommer fel i CF2-systemet, indikeras det med masterregulatorn
och direkt på ärrkontrollens display:
När larmet godkänts med OK, kommer masterregulatorns summer att stängas
av (om ljudet är påslaget, se avsnitt 5.3), så kommer CF2-systemet att gå över
till Larmstatus som visas på startskärmen:
Denna indikation av Larm på ärrkontrollen och indikationen på masterregu-
latorn kommer att fortsätta tills det fel som orsakade larmet har korrigerats.
82
Bruksanvisning CF-RC Fjärrkontroll
VI.UH.M5.1C Tillverkad av Danfoss Floor Heating Hydronics 08.2009
Menyn Larm kommer att visas överst på menylistan som aktiveras från start-
bilden:
Aktivering av menyn Larm med OK ger tillgång till en Larmstatus, där du
kan se en beskrivning av det fel som orsakade larmet. Dessutom kan du välja
Larmlogg för att få mer specik information om det fel som orsakade larmet
och tidpunkten när systemet registrerade felet. Denna Larmlogg sparar de
senaste larmen så att du senare kan få tillgång till dem och enkelt kan identi-
era fel i systemet. När det inte nns något fel som orsakar ett larm kan du få
tillgång till Larmlogg via menyn Inställningar (se avsnitt 5.3).
6. Avinstallation
Nollställning av ärrkontroll, CF-RC - bild 1:
Aktivera funktionsknapp 1 , funktionsknapp 2 och nerknappen samtidigt.
Fjärrkontrollen ber om din bekräftelse innan den nollställs.
Om du bekräftar med Ja” nollställs ärrkontrollen
Efter att du nollställt med Ja är ärrkontrollen nu klar att installeras till en
masterregulator av typen CF-MC
Observera! Se bruksanvisning för masterregulatorn, CF-MC för er detaljer
Bruksanvisning CF-RC Fjärrkontroll
VI.UH.M5.1C Tillverkad av Danfoss Floor Heating Hydronics 08.2009
83
SE
7. Andra produkter till CF2-systemet och förkortningar
Andra produkter till CF2-systemet - bild 5
a) Masterregulator, CF-MC: MC
b) Rumstermostat, CF-RS, -RD, -RP och –RF: Rumst.
c) Repeaterenhet, CF-RU: RU
8. Specifikationer
Kabellängd (nätledning) 1,8m
Kommunikationsfrekvens 868,42MHz
Kommunikationsräckvidd i byggnader (upp till) 30m
Antal repeaterenheter i en kedja (upp till) 3
Kommunikationseekt < 1mW
Försörjningsspänning 230V AC
Omgivande temperatur 0-50°C
Kapslingsgrad IP 21
84
Bruksanvisning CF-RC Fjärrkontroll
VI.UH.M5.1C Tillverkad av Danfoss Floor Heating Hydronics 08.2009
9. Felsökning
Felindikation Möjlig orsak
Termomotor/utgång
(E03)
Utgången på masterregulatorn (MC) eller den termo-
motor som är ansluten till denna utgång är kortsluten
eller avbruten
Låg temperatur (E05) Temperaturen i rummet är under 5° C. (Försök att veri-
era om rumstermostaten fungerar genom att utföra ett
länktest från den)
Länk till masterregulator
(E12)
Rumstermostaten i det angivna rummet har förlorat
den trådlösa anslutningen till masterregulatorn (MC)
Svagt batteri för rummet.
(E13)
Batteriet för rumstermostaten för det angivna rummet
är svagt, och batterierna bör bytas ut
Kritiskt svagt batteri för
rummet. (E14)
Batteriladdningen för rumstermostaten för det angivna
rummet är kritiskt svagt, och batterierna bör bytas ut
så snabbt som möjligt
Länk mellan MC:er (E24) De angivna masterregulatorerna har förlorat sin
trådlösa anslutning
Batterierna för ärrkontrollen är svaga och de bör
bytas ut
Instrukcja obsługi pilota CF-RC
VI.UH.M5.1C Wyprodukowane przez Danfoss Floor Heating Hydronics 08.2009
85
PL
PL
Spis treści
10. Rysunki .................................................................................. A1-A2
1. Przegląd funkcji ............................................................................ 86
2. Instalacja ...................................................................................... 87
3. Test transmisji .............................................................................. 88
4. Mocowanie .................................................................................... 88
5. Menu .............................................................................................. 89
5.1 Pomieszczenia .............................................................................................................89
5.2 Program .........................................................................................................................91
5.3 Konguracja .................................................................................................................95
5.4 Alarmy ............................................................................................................................97
6. Odinstalowanie ............................................................................ 98
7. Inne podzespoły systemu CF2 oraz stosowane skróty ............. 99
8. Specyfikacje .................................................................................. 99
9. Usuwanie usterek ....................................................................... 100
86
Instrukcja obsługi pilota CF-RC
VI.UH.M5.1C Wyprodukowane przez Danfoss Floor Heating Hydronics 08.2009
1. Przegląd funkcji
Przód – rys. 1
Wyświetlacz
Klawisz programowania 1
Klawisz programowania 2
Przycisk góra/dół
Przycisk lewa/prawa
Ikona alarmu systemu
Ikona komunikacji z regulatorem
Ikona przełączania na zasilanie 230V
Ikona niskiego poziomu naładowania baterii
Uwaga: Pilot posiada przejrzystą strukturę menu, a wszystkie ustawienia można z łatwością
wykonywać za pomocą przycisków góra/dół i lewa/prawa w połączeniu z funkcjami klawiszy
programowania, które znajdują się nad nimi na wyświetlaczu.
Tył – rys. 2
Tylna płyta/stacja dokująca
Komora baterii
Otwory do montażu ściennego stacji dokującej
Śruba montażowa
Transformator z wtykiem zasilania ~ 230 V
Uwaga: Zdjąć paski ochronne z załączonych baterii w celu uruchomienia pilota.
Instrukcja obsługi pilota CF-RC
VI.UH.M5.1C Wyprodukowane przez Danfoss Floor Heating Hydronics 08.2009
87
PL
2. Instalacja
Uwaga:
Instalację pilota należy wykonać po zainstalowaniu wszystkich termostatów pomieszczeń,
które mają pracować w instalacji. – patrz rys. 5 b.
Zdjąć paski ochronne z baterii w celu uruchomienia pilota.
Rejestrować pilota do regulatora w odległości nie większej niż 1½ m.
Kiedy podświetlenie ekranu jest wyłączone, można je włączyć naciskając dowolny przycisk.
Aktywacja trybu instalacji - pilot – rys. 3
Za pomocą przycisku wyboru menu wybrać tryb instalacji. Miga dioda
instalacji .
Aktywować tryb instalacji naciskając OK . Zapala się dioda instalacji .
Aktywacja trybu instalacji w regulatorze – rys. 1
Po podłączeniu baterii wykonywać wszystkie działania zgodnie z instrukcją
instalacji rozpoczynając kongurację od wyboru języka menu.
Po wykonaniu instalacji ustawić godzinę i datę. Ustawienia wykonać za
pomocą przycisku góra/dół oraz lewa/prawa . Ustawienia potwierdzić
aktywowanym klawiszem programowania 1 ( ).
Na końcu procesu montażu można nadać nazwy pomieszczeniom, w których
znajdują się termostaty. Znacznie ułatwia to obsługę i dostęp do systemu.
W menu Nazwy pomieszczeń, za pomocą przycisku programowania 2 ( ),
aktywować menu Zmień, aby zmienić domyślne nazwy pomieszczeń, np.
„MC1 Output 1.2” (regulator 1, wyjście 1 i 2) na „Pokój gościnny”, i zatwierdzić
zmiany naciskając przycisk OK. Można także użyć menu Literuj…. w celu
utworzenia innych nazw.
Kiedy instalacja zostanie zakończona na wyświetlaczu pojawi się ekran
początkowy z aktualnym czasem i datą u góry. Wyświetlona zostanie także
aktualna temperatura w pomieszczeniu w górnej części listy pomieszczeń.
W celu wybrania kolejnego pomieszczenia patrz rozdział 5.3
Uwaga: przytrzymując przycisk aktywacji przyspieszamy zmianę nastawianych wartości.
88
Instrukcja obsługi pilota CF-RC
VI.UH.M5.1C Wyprodukowane przez Danfoss Floor Heating Hydronics 08.2009
3. Test transmisji
Rozpoczęcie testu transmisji z pilota
Na ekranie początkowym wybrać:
Menu
Konguracja
Test połączenia
Menu Test połączenia służy do rozpoczęcia testu transmisji bezprzewodowej
między regulatorem a pilotem. Status tego testu zostanie wyświetlony zaraz
po jego zakończeniu.
W przypadku nieudanego testu połączenia należy:
• Ustawić pilota w innym miejscu w pomieszczeniu
• Lub zamontować wzmacniacz sygnału (CF-RU, patrz rys. 5) i umieścić go
między regulatorem (CF-MC) a pilotem (CF-RC).
Uwaga: W zależności od wielkości systemu, test połączenia może trwać nawet kilka minut.
4. Mocowanie
Pilot został zainstalowany – rys. 2
Kiedy pilot został zainstalowany na regulatorze (patrz 2), można go zamocow
na ścianie za pomocą tylnej płyty/stacji dokującej .
Umożliwia to podłączenie pilota do źródła zasilania 230V za pomocą dostar-
czonego transformatora/wtyczki zasilania . Jeśli nie znajduje się on w stacji
dokującej, jest zasilany dwoma alkalicznymi bateriami AA 1,5V.
Instrukcja obsługi pilota CF-RC
VI.UH.M5.1C Wyprodukowane przez Danfoss Floor Heating Hydronics 08.2009
89
PL
• Przed umieszczeniem tylnej płyty/stacji dokującej na ścianie , należy
przeprowadzić test połączenia, aby potwierdzić transmisję z regulatora
umieszczonego w wybranym miejscu (patrz 3).
Zamocować tylną płytę/stację dokującą na ścianie za pomocą śrub
montażowych .
Podłączyć stację dokującą do gniazdka zasilania 230V za pomocą transforma-
tora/wtyczki zasilania .
• Umieścić pilota w stacji dokującej .
Uwaga: Aby zwiększyć zakres transmisji systemu CF2, można zamontować maks. 3 wzmac- zamontować maks. 3 wzmac-
niacze sygnału między regulatorem a termostatem – patrz rys. 4.
5. Menu
Uwaga: Kiedy podświetlenie ekranu jest wyłączone, można je włączyć naciskając dowolny
przycisk.
5.1 Pomieszczenia
Na ekranie początkowym wybrać:
Menu
Pomieszczenia
Menu Pomieszczenia pozwala uzyskać dostęp do wszystkich pomieszczeń
w systemie. Wybrać dane pomieszczenie i nacisnąć OK, aby wyświetlić jego
ekran. Na ekranie tym znajdują się wszystkie informacje na temat ustawionej i
rzeczywistej temperatury w pomieszczeniu:
: Informuje, że pokój ten należy do bieżącego programu czasowego
(patrz 5.2)
: Informuje o niskim poziomie naładowania baterii termostatu
90
Instrukcja obsługi pilota CF-RC
VI.UH.M5.1C Wyprodukowane przez Danfoss Floor Heating Hydronics 08.2009
: Informuje, że wartość ustawiona na termostacie pomieszczenia
wykracza poza górną/dolną granicę ustawioną przez pilota
: Informuje, że ustawiona temperatura jest wyższa od rzeczywistej
: Informuje, że ustawiona temperatura jest niższa od rzeczywistej
5.1.1 Opcje
W menu pomieszczenia można aktywować menu Opcje, które umożliwia
dostęp do różnych opcji dla pomieszczenia:
Nastawa temperatury:
Tu można ustawić i zablokować temperaturę dla termostatu pomieszczenia.
Blokada uniemożliwia regulację temperatury termostatem zainstalowanym
w wybranym pomieszczeniu.
Nastawa dolnej/górnej granicy:
Tu można ustawić i zablokować dolną oraz górną granicę temperatury dla ter-
mostatu pomieszczenia. Blokada uniemożliwia zmianę nastawy na termostacie
w wybranym pomieszczeniu poza tymi granicami.
Zmiana nazwy pomieszczenia:
Tutaj można zmieniać nazwy pomieszczeń wykorzystując listę możliwych
nazw lub wpisując nazwy za pomocą menu Nazwij.
Nastawa temp podł min/max:
Tu można ustawić i zablokować dolną oraz górną granicę temperatury podłogi.
Funkcja dostępna tylko w przypadku termostatu pomieszczenia z podłogowym czujnikiem
podczerwieni CF-RF. Ograniczenie to ma priorytet w stosunku do zadanej temperatury
w pomieszczeniu.
Obniżenie:
Tu można unieważnić trwający albo któryś kolejny program obniżenia. (patrz 5.2.2).
Instrukcja obsługi pilota CF-RC
VI.UH.M5.1C Wyprodukowane przez Danfoss Floor Heating Hydronics 08.2009
91
PL
Chłodzenie:
Tu można wyłączyć funkcję chłodzenia danego pomieszczenia.
Funkcja dostępna tylko, gdy regulator jest w trybie chłodzenia.
5.2 Program
Na ekranie początkowym wybrać:
Menu
Program
Menu Program pozwala wybrać jedną z dwóch opcji programowania:
5.2.1 Program wakacyjny:
Za pomocą tego programu można ustawić temperaturę we wszystkich
pomieszczeniach na czas, np. urlopu. Datę rozpoczęcia i zakończenia okresu
można z łatwością ustawić za pomocą funkcji kalendarza, wykorzystując przy-
ciski góra/dół oraz lewa/prawa (rys. 1 – / ) oraz potwierdzając każde usta-
wienie naciśnięciem przycisku OK. Temperatura pomieszczenia oraz czas trwa-
nia programu okresowego są wyświetlane i aktywowane na szczegółowym
przeglądzie stworzonego programu:
92
Instrukcja obsługi pilota CF-RC
VI.UH.M5.1C Wyprodukowane przez Danfoss Floor Heating Hydronics 08.2009
5.2.2 Program obniżenia:
W menu Program obniżenia można przyporządkować poszczególne po-ć poszczególne po-
mieszczenia do sześciu oddzielnych stref. Do każdej ze stref można przypisać
maks.3 programy obniżenia. Każdy z nich może zawierać 3 okresy obniżenia
w ciągu doby. Do każdego z programów obniżenia można przypisać poszcze-
gólne dni w których będzie obowiązywał. Szczegóły poniżej.
Opcje:
Każda strefa posiada ekran pokazujący znajdujące się w nim pokoje.
Zapewniają one dostęp do menu Opcje z funkcją Dodaj pomieszczenie oraz
maks. 3 Programami obniżenia.
Dodaj pomieszczenie:
W tym menu wszystkie pokoje są oznaczone za pomocą ( ), co pokazuje,
w której stree znajduje się dany pokój (patrz rys. poniżej ). Domyślnie ws-
zystkie pokoje przypisane są do strefy 1. Po stworzeniu nowych stref możemy
dowolnie przyporządkowywać poszczególne pomieszczenia dzieląc obiekt na
strefy (np. ze strefy 1 do 3 – patrz rys. poniżej).
Program 1 - 3:
Menu Opcje zawiera także możliwe programy obniżenia dla każdej strefy, któ-
re możemy dowolnie modykować zadając maksymalnie 3 okresy obniżenia
w ciągu doby dla każdego z nich.
Szczegóły poniżej. Procedura tworzenia lub zmiany programu jest taka sama
dla każdego z nich:
Instrukcja obsługi pilota CF-RC
VI.UH.M5.1C Wyprodukowane przez Danfoss Floor Heating Hydronics 08.2009
93
PL
Za pomocą przycisku OK aktywować program (1-3) z menu Opcje i wybrać
dni należące do tego programu:
Za pomocą przycisków góra/dół i lewa/prawa (rys. 1- / ) wybrać dni przy-
pisane do programu przenosząc je nad poziomą linię na ekranie. Potwierdzić
naciskając OK i wybrać czas programu obniżenia.
Czarna linia nad osią czasu oznacza, że w tym okresie czasu będzie utrzy-
mywana temperatura komfortu (zadana na termostacie w danym pomieszc-
zeniu). Przedziały bez pasków nad osią czasu oznaczają, że w tym czasie
obowiązuje temperatura obniżona. Zmian długości poszczególnych okresów
dokonujemy używając przycisku lewo/prawo oraz góra/dół (g. 1- / ).
Aby usunąć drugi okres z tem-ąć drugi okres z tem-
peraturą komfortu w pomiesz-
czeniu , należy zmienić czas
zakończenia tego okresu na
czas jego rozpoczęcia.
94
Instrukcja obsługi pilota CF-RC
VI.UH.M5.1C Wyprodukowane przez Danfoss Floor Heating Hydronics 08.2009
Drugi okres z normal
temperaturą pomieszczenia
można ponownie dodać
do programu przechodząc do
niego przez pierwszy okres za
pomocą przycisku góra/dół .
Za pomocą przycisku OK potwierdzić wybrane okresy, aby aktywować
utworzony program - patrz poniższa ilustracja:
Uwaga: Poszczególne dni tygodnia są opisane pierwszymi literami ich nazw. Litery
okreslające dni wybrane w programie oznaczone są wytłuszczonym drukiem.
Anuluj program:
Utworzony program można usunąć wybierając w menu NIE – patrz powyższa
ilustracja.
Uwaga:
W menu Opcje utworzone programy (1-3) będą oznaczone wyróżniającymi się pierwszymi
literami ich nazw.
Unieważnić program obniżenia w poszczególnych pomieszczeniach można korzystając
z funkcji Kasuj obniżenie dostępnej w menu Opcje (patrz 5.1.1).
Instrukcja obsługi pilota CF-RC
VI.UH.M5.1C Wyprodukowane przez Danfoss Floor Heating Hydronics 08.2009
95
PL
Temperatura obniżenia:
W funkcji Program obniżenia (patrz 5.2.2) aktywować menu Temperatura
obniżenia, aby ustawić obniżenie temperatury w pomieszczeniu w zakresie
od 1 do 10°C podczas okresu obniżenia.
5.3 Konfiguracja
Na ekranie początkowym wybrać:
Menu
Konguracja
Menu Konfiguracja umożliwiaja dostęp do wielu informacji oraz możliwości
konguracji pilota oraz całego systemu CF2.
Uwaga: Jako, że niektóre nastawy w menu Konguracja mogą mieć wpływ na ogólną
kongurację systemu CF2 i sposób działania całej aplikacji, należy je obsługiwać ze
szczególną uwagą.
Języki:
Tutaj można wybrać język inny od tego, który został wybrany podczas procesu
instalacji (patrz 2).
Data i godzina:
Umożliwia dostęp do opcji ustawiania daty i godziny. Co więcej, menu to
zawiera ustawienia umożliwiające obsługę i aktywowanie programu działania
w czasie lata. Dzięki nim, można ustawić dzień, tydzień i miesiąc oznaczające
początek i koniec lata.
Alarm:
W tym menu można włączać/wyłączać sygnał dźwiękowy regulatora (CF-MC).
Jest on emitowany tylko w przypadku alarmu, podczas którego miga także
czerwona dioda alarmowa na regulatorze (patrz rys. 3- ).
96
Instrukcja obsługi pilota CF-RC
VI.UH.M5.1C Wyprodukowane przez Danfoss Floor Heating Hydronics 08.2009
W Rejestrze alarmów można uzyskać szczegółowe informacje na temat
błędu, który wywołał alarm oraz czas jego rejestracji przez system. Rejestr
alarmów zapisuje wszystkie alarmy, aby ułatwić późniejsze określenie przy-
czyny błędu systemu.
Ekran początkowy:
Tu można wybrać temperaturę pomieszczenia, która ma być wyświetlana na
ekranie początkowym.
Serwis:
Tu można skongurować wszystkie wyjścia regulatora (patrz rys. 5-a) dla sy-
stemu ogrzewania podłogowego lub grzejnikowego. Ogrzewanie podłogowe
jest ustawiane za pomocą funkcji Wł./Wył. lub PWM (modulacja szerokości
impulsu). Wybór tradycyjnego grzejnika powoduje automatyczne ustawie-
nie regulacji na PWM. Poprzez ustawienie wyjść regulatora na ogrzewanie
podłogowe lub tradycyjne grzejniki w danym pokoju można wybrać nawet
mieszany system ogrzewania (podłogowe i grzejnikowe).
Uwaga: Kiedy regulator jest regulowany przez PWM, stosowane są następujące cykle działania:
Ogrzewanie podłogowe: 2 godziny
Ogrzewanie grzejnikowe: 15 minut.
W menu Serwis, za pomocą przycisku OK, aktywować funkcję Temperatura
czuwania, aby ustawić stałą temperaturę dla wszystkich termostatów
pomieszczeń w zakresie od 5 do 35°C, kiedy wejście czuwania jest aktywowane
w regulatorze (patrz instrukcja obsługi regulatora CF-MC).
Kontrast:
Tutaj można ustawić kontrast wyświetlacza pilota.
Test połączenia:
Aktywuje test połączenia w celu sprawdzenia działania komunikacji bezpze-ziałania komunikacji bezpze-
wodowej z i do pilota (patrz 3).
Instrukcja obsługi pilota CF-RC
VI.UH.M5.1C Wyprodukowane przez Danfoss Floor Heating Hydronics 08.2009
97
PL
Znajdź regulator nadrzędny:
Funkcja ta umożliwia określenie jednego głównego regulatora w systemie
obejmującym maks. 3 takie regulatory. Po aktywacji tej funkcji, określony
główny regulator spowoduje kilkukrotne włączenie i wyłączenie wszystkich
diod wyjściowych 1 - 10 w celu ułatwienia jego identykacji.
5.4 Alarmy
Jeśli w systemie CF2 wystąpi błąd, jest on wyświetlany przez regulator na
wyświetlaczu pilota:
Kiedy alarm zostanie potwierdzony naciśnięciem przycisku OK, sygnał
dźwiękowy regulatora wyłączy się (jeśli sygnał ten jest aktywowany – patrz
5.3), a system CF2 przejdzie do Statusu alarmu wskazywanego na ekranie
głównym:
Wskazanie Alarmu na pilocie oraz wskazanie na regulatorze będzie wyświetlane
do momentu usunięcia błędu.
98
Instrukcja obsługi pilota CF-RC
VI.UH.M5.1C Wyprodukowane przez Danfoss Floor Heating Hydronics 08.2009
Menu Alarmy będzie znajdować się w górnej części listy menu aktywowanej
z ekranu głównego:
Aktywacja tego menu za pomocą przycisku OK zapewnia dostęp do Statusu
alarmu, gdzie znajdują się opisy błędów będących przyczyną alarmu. Co więcej,
można także aktywować Rejestr alarmów, aby uzyskać szczegółowe informacje
na temat błędu, który spowodował alarm oraz czasu jego rejestracji w systemie.
Rejestr alarmów zapisuje wszystkie alarmy, aby ułatwić późniejsze określenie
przyczyny błędu systemu. Kiedy w systemie nie ma błędu powodującego alarm,
do rejestru alarmów można wejść przez menu Konfiguracja (patrz 5.3).
6. Odinstalowanie
Resetowanie pilota CF-RC - rys. 1:
Nacisnąć jednocześnie klawisze programowania 1 i 2 oraz przycisk
„w dół”.
Pilot wymaga potwierdzenia polecenia resetowania. Polecenie potwierdzenia
Tak powoduje jego zresetowanie.
Po wydaniu tego polecenia pilot jest gotowy do instalacji w regulatorze CF-MC.
Uwaga: Więcej informacji na ten temat znajduje się w instrukcji obsługi regulatora!
Instrukcja obsługi pilota CF-RC
VI.UH.M5.1C Wyprodukowane przez Danfoss Floor Heating Hydronics 08.2009
99
PL
7. Inne podzespoły systemu CF2 oraz stosowane skty
Inne podzespoły systemu CF2 – rys. 5
a) Regulator, CF-MC: MC
b) Termostat pomieszczenia, CF-RS, -RD, -RP i –RF: Room T
c) Wzmacniacz sygnału, CF-RU: RU
8. Specyfikacje
Długość kabla (zasilanie) 1,8m
Częstotliwość transmisji 868,42 MHz
Zakres transmisji w budynkach (maks.) 30m
Liczba wzmacniaczy sygnału w sieci (maks.) 3
Moc transmisji < 1mW
Napięcie zasilania 230V prąd zmienny
Temperatura otoczenia 0-50°C
Klasa IP 21
100
Instrukcja obsługi pilota CF-RC
VI.UH.M5.1C Wyprodukowane przez Danfoss Floor Heating Hydronics 08.2009
9. Usuwanie usterek
Wskazanie błędu Możliwe przyczyny
Siłowniki/wyjście (E03) Zwarcie lub rozłączenie wyjścia regulatora (MC) lub
siłownika podłączonego do tego wyjścia.
Niska temperatura (E05) Temperatura w pomieszczeniu wynosi poniżej 5°C.
(Sprawdzić funkcjonowanie termostatu wykonując
z niego test połączenia.)
Połączenie z regulatorem
(E12)
Termostat pomieszczenia w danym pomieszczeniu
utracił połączenie bezprzewodowe z regulatorem (MC).
Niski poziom
naładowania baterii
w termostacie (E13)
Poziom naładowania baterii w termostacie w danym
pomieszczeniu jest niski - wymienić baterie.
Krytyczny poziom
naładowania baterii
w termostacie (E14)
Poziom naładowania baterii w termostacie w danym
pomieszczeniu jest krytycznie niski – natychmiast
wymienić baterie.
Połączenie między
regulatorami (E24)
Dany regulator utracił połączenie bezprzewodowe.
Niski poziom naładowania baterii w pilocie – wymienić
baterie.
Handleiding CF-RC Afstandsbediening
VI.UH.M5.1C Geproduceerd door Danfoss Floor Heating Hydronics 08.2009
101
NL
NL
Inhoud
10. Afbeeldingen ........................................................................ A1-A2
1. Functies overzicht ....................................................................... 102
2. Installatie / aanmelding ............................................................ 102
3. Verbindingstest .......................................................................... 104
4. Montage ...................................................................................... 104
5. Menu’s .......................................................................................... 105
5.1 Ruimtes ....................................................................................................................... 105
5.2 Programma ............................................................................................................... 107
5.3 Instellingen ............................................................................................................... 111
5.4 Alarmmeldingen ..................................................................................................... 114
6. Resetten ...................................................................................... 115
7. Andere producten voor het CF2-systeem en afkortingen ...... 116
8. Specificaties ................................................................................116
9. Probleemoplossing .................................................................... 117
102
Handleiding CF-RC Afstandsbediening
VI.UH.M5.1C Geproduceerd door Danfoss Floor Heating Hydronics 08.2009
1. Functies overzicht
Voorzijde – fig. 1
Display
Keuzetoets 1
Keuzetoets 2
Keuzetoets hoger/lager
Keuzetoets links/rechts
Indicatie voor systeem alarm
Indicatie voor communicatie met regelaar
Indicatie voor overschakeling naar 230V voeding
Indicatie voor lage batterijspanning
Opmerking: de afstandsbediening heeft een duidelijke menustructuur. Alle instellingen
kunnen gemakkelijk worden uitgevoerd met de keuzetoetsen hoger/lager en links/
rechts, in combinatie met de functies van de keuzetoetsen die erboven in het display
worden weergegeven.
Achterzijde – fig. 2
Muurplaat/docking station
Batterijcompartiment
Schroefgat voor wandmontage
Schroeven en pluggen
Transformator/voedingsstekker
Opmerking: verwijder de strip om de bijgeleverde batterijen in gebruik te nemen.
2. Installatie / aanmelding
Opmerking:
Meld de afstandsbediening pas aan nadat u alle kamerthermostaten hebt geïnstalleerd,
zie g. 5-b.
Verwijder de strip om de bijgeleverde batterijen in gebruik te nemen.
Handleiding CF-RC Afstandsbediening
VI.UH.M5.1C Geproduceerd door Danfoss Floor Heating Hydronics 08.2009
103
NL
Meld de afstandsbediening aan bij de regelaar(master) op een afstand van maximaal 1,5 m.
Wanneer de achtergrondverlichting in het display gedoofd is, heeft het aanraken van een
willekeurige toets als enige effect dat de achtergrondver lichting wordt geactiveerd.
Activeer de aanmeldprocedure op de regelaar – fig. 3
Gebruik de menu keuze toets om de aanmeldprocedure te starten. De led
Install knippert
Activeer het aanmelden door op de OK toets te drukken. De led Install
gaat branden.
Activeer de aanmeldprocedure op de afstandbediening – fig. 1
Wanneer de batterijen zijn aangesloten, volgt u het menu in het scherm,
beginnend met de taalkeuze.
Na de aanmelding voert u de tijd en de datum in. Gebruik de keuze toets
hoger/lager en de keuzetoets links/rechts om de instellingen uit te voeren.
Bevestig de instellingen door de OK toets in te drukken. Fig.1
Het installatieproces wordt afgesloten met de mogelijkheid om de ruimtes
waarin de kamerthermostaten zijn geplaatst, een naam te geven. Hierdoor
wordt de herkenbaarheid van de ruimtes in het systeem eenvoudig.
In het menu Naam ruimtes activeert u het menu wijzigen met keuze toets
( ) om de standaard kamernamen te wijzigen van bijv. MC1 Output 1.2
(hoofdregelaar 1, uitgang 1 en 2) in woonkamer, en bevestig met de Ok toets.
U kunt ook het menu spellen… gebruiken om andere namen in te voeren.
Wanneer de installatieprocedure is afgerond dan zal het opstartscherm in
het display verschijnen met daarin de actuele tijd en datum. In het display
verschijnt tevens de actuele ruimtetemperatuur van de ruimte die bovenaan
de lijst vermeld staat . ( zie hoofdstuk 5.3 om een andere ruimte van de lijst te
selecteren.
Opmerking: Door een keuze toets ingedrukt te houden zal de instelling sneller veranderen.
104
Handleiding CF-RC Afstandsbediening
VI.UH.M5.1C Geproduceerd door Danfoss Floor Heating Hydronics 08.2009
3. Verbindingstest
Start de verbindingstest op de afstandbediening.
In het opstartscherm kiest u:
Menu
Instelling
Verbindingstest
Kies het Verbindingstest-menu om een test van de draadloze verbinding tussen
de regelaar en de afstandbediening te starten. Het resultaat van de verbindings-
test zal onmiddellijk na het uitvoeren van de test worden weergegeven.
Als de verbindingstest niet gelukt is:
Probeer dan om de afstandbediening op een andere plaats in de ruimte te
houden,
Of installeer een signaalversterker (CF-RU, zie g. 5c) en plaats die tussen de
regelaar en de afstandsbediening.
Opmerking: de verbindingstest kan enkele minuten duren, afhankelijk van de grootte van
het systeem.
4. Montage
De afstandsbediening is aangemeld – fig. 2
Wanneer de afstandsbediening is aangemeld op de regelaar (zie 2), dan kan
deze op de wand worden gemonteerd door middel van de muurplaat/
docking station . Hierdoor wordt het mogelijk om de afstandbediening op een
230V voeding aan te sluiten met de bijgeleverde transformator/voedingstekker
Handleiding CF-RC Afstandsbediening
VI.UH.M5.1C Geproduceerd door Danfoss Floor Heating Hydronics 08.2009
105
NL
Wanneer de afstandbediening niet in het docking station zit, wordt deze
gevoed door twee AA alkalinebatterijen van 1,5 V. (niet oplaadbaar)
Voordat u de muurplaat/docking station op de muur plaatst, controleert u
het zendbereik naar de regelaar vanaf de gewenste plaats door een verbin-
dingstest uit te voeren (zie 3).
Monteer de muurplaat/docking station op de wand met de bijgeleverde
schroeven en de pluggen .
Sluit de muurplaat/docking station aan op een 230V voeding door middel
van de transformator/voedingstekker .
Plaats de afstandsbediening op de muurplaat/docking station.
Opmerking: om het zendbereik van het CF2-systeem te vergroten, kunnen tot maximaal
drie signaalversterkers in serie worden geplaatst – zie g. 4.
5. Menus
Opmerking: • Wanneer de achtergrondverlichting in het display gedoofd is, heeft het
aanraken van een willekeurige toets als enige effect dat de achtergrondver lichting wordt
geactiveerd.
5.1 Ruimtes
In het opstartscherm kiest u:
Menu
Ruimtes
Kies het menu Ruimtes om een lijst van alle ruimtes in het systeem te openen.
Kies de gewenste ruimte met de hoger / lager toetsen en bevestig met de
OK toets om het scherm voor die ruimte te openen. Hier kunt u de informatie
bekijken over de ingestelde en de actuele temperatuur:
106
Handleiding CF-RC Afstandsbediening
VI.UH.M5.1C Geproduceerd door Danfoss Floor Heating Hydronics 08.2009
: Geeft aan dat deze ruimte is opgenomen in een lopend tijdprogramma
(zie 5.2).
: Geeft aan dat de batterij van de kamerthermostaat bijna leeg is.
: Geeft aan dat de waarde die op de kamerthermostaat werd ingesteld,
buiten de max.-min.limieten ligt die op de afstandbediening is ingesteld
: Geeft aan dat de ingestelde temperatuur hoger is dan de werkelijke
temperatuur
: Geeft aan dat de ingestelde temperatuur lager is dan de werkelijke
temperatuur.
5.1.1 Opties
In het ruimtevenster kunt u een menu Opties openen, met toegang tot de
verschillende opties voor de ruimte:
Ingestelde temperatuur:
Hier kunt u de ingestelde temperatuur voor de kamerthermostaat instellen,
begrenzen en eventueel vergrendelen. Het vergrendelen voorkomt dat de in-
gestelde minimum en maximum temperatuur op de kamerthermostaat wordt
gewijzigd.
Instellen min./max. begrenzing:
Hier kunt u de minimum- en maximumtemperatuur voor de kamerthermos-
taat instellen en vergrendelen. Het vergrendelen voorkomt dat de tempera-
tuur op de kamerthermostaat, buiten deze grenzen kan worden ingesteld.
Naam ruimte wijzigen:
Hier kunt u de naam van de ruimte wijzigen door middel van een lijst van mo-
gelijke namen. U kunt ook het menu spellen… gebruiken om de ruimte een
andere naam te geven.
Instellen vloer min./max. begrenzing:
Hier kunt u de minimale en maximale vloeroppervlaktetemperaturen instel-
len, begrenzen en eventueel vergrendelen. Het vergrendelen voorkomt dat
Handleiding CF-RC Afstandsbediening
VI.UH.M5.1C Geproduceerd door Danfoss Floor Heating Hydronics 08.2009
107
NL
de temperatuur op de kamerthermostaat, buiten deze grenzen kan worden
ingesteld.
Alleen beschikbaar met kamerthermostaat met infrarood vloersensor, CF-RF.
Nachtverlaging:
Hier kunt u kiezen om de volgende of lopende (nacht)verlagingsperiode te
annuleren (zie 5.2.2).
Koeling:
Hier kunt u de koelfunctie voor de betreende ruimte uitschakelen.
Alleen beschikbaar wanneer de hoofdregelaar in de koelstand staat.
5.2 Programma
In het opstartscherm kiest u:
Menu
Programma
Kies het menu Programma om de twee programma opties te bekijken:
5.2.1 Vakantieprogramma
Met dit programma kunt u de kamertemperatuur voor alle kamerthermos-
taten instellen, bijv. voor een vakantieperiode. De begin- en einddatum voor
het programma kunnen gemakkelijk in een kalender worden bepaald met de
keuze toetsen hoger/lager en links/rechts (g. 1 / ) en door elke instelling
te bevestigen met de OK. toets. De kamertemperatuur en de duur van het
vakantieprogramma worden weergegeven en ten slotte geactiveerd in een
gedetailleerd overzicht van het gecreëerde programma:
108
Handleiding CF-RC Afstandsbediening
VI.UH.M5.1C Geproduceerd door Danfoss Floor Heating Hydronics 08.2009
5.2.2 Klokprogramma
In het menu klokprogramma kunt u de verschillende ruimtes indelen in
maximaal zes verschillende zones. Voor iedere zone kunnen maximaal
drie verschillende klokprogrammas worden geprogrammeerd, met verschil-
lende temperaturen op verschillende tijdstippen van de dag.
Opties:
Elke zone heeft een venster waarin de ruimtes die tot de zone behoren, wor-
den weergegeven. Hierin is een menu Opties beschikbaar, met een functie
Ruimte toevoegen en drie klokprogrammas (maximaal).
Ruimte toevoegen:
In dit menu worden alle ruimtes gevolgd door een (waarde) waarin wordt
aangegeven tot welke zone iedere ruimte behoort (zie onderstaande guur).
Standaard worden alle ruimtes toegewezen aan Zone 1. Wanneer nieuwe
zones worden gecreëerd, zullen de ruimtes worden verplaatst van de zone
waaraan ze waren toegewezen naar de nieuwe zone (van zone 1 naar zone 2
in de onderstaande figuur).
Handleiding CF-RC Afstandsbediening
VI.UH.M5.1C Geproduceerd door Danfoss Floor Heating Hydronics 08.2009
109
NL
Programma 1 – 3:
Het menu Opties bevat ook drie mogelijke klokprogrammas met elk 2 com-
fortperiodes voor iedere zone. Hiermee kunnen de zeven dagen van de week
worden ondergebracht in maximaal drie verschillende klokprogrammas met
verschillende dagen en verschillende comfortperiodes voor elk programma.
De procedure voor het creëren of wijzigen van een programma is hetzelfde
voor de drie programmas:
Activeer programma (1-3) in het menu Opties. Na OK kunt u de dagen voor
dit programma kiezen:
Gebruik de keuzetoetsen hoger/lager en links/rechts (g. 1-) om de
dagen voor dit programma te kiezen, door ze boven de horizontale lijn te
plaatsen. Bevestig met de OK toets.
Kies nu de schakeltijden voor het klokprogramma door de periodes in te
stellen waarin u een normale kamertemperatuur wilt, aangegeven door de
110
Handleiding CF-RC Afstandsbediening
VI.UH.M5.1C Geproduceerd door Danfoss Floor Heating Hydronics 08.2009
zwarte balkjes boven de tijdlijn (de perioden buiten de zwarte balken zijn
de nachtverlaging periodes met verlaagde kamertemperatuur). Stel de begin-
en eindtijd in met behulp van de keuze toets links/rechts en spring naar het
volgende / vorige schakelpunt m.b.v. de keuzetoets hoger/lager (g.1).
U kunt de tweede comfortperiode met de normale kamertemperatuur ver-
wijderen door de eindtijd voor deze periode te wijzigen in de begintijd:
De tweede periode , kan
opnieuw worden toegevoegd
door middel van de keuze toets
hoger/lager en door de eer-
ste periode te kiezen .
Bevestig de gekozen tijdperi-
odes met de OK toets om het
vanuit dit overzicht gecreëerde
programma te activeren:
Handleiding CF-RC Afstandsbediening
VI.UH.M5.1C Geproduceerd door Danfoss Floor Heating Hydronics 08.2009
111
NL
Opmerking: de dagen die in het programma zijn geselecteerd, worden aangegeven door
duidelijker weergegeven beginletters.
Programma annuleren:
Een gecreëerd klokprogramma kan worden gewist met het menu Programma
annuleren dat leidt tot het hierboven weergegeven overzicht.
Opmerking:
• In het menu Opties zullen de gecreëerde programma’s (1-3) worden aangegeven met
duidelijker weergegeven hoofdletters.
Als u een klokprogramma in een ruimte wilt negeren , dan kunt u dit voor iedere ruimte
doen met de functie nachtverlaging in het menu Opties (zie 5.1.1).
Temperatuur nachtverlaging:
In het klokprogramma (zie 5.2.2) activeert u het menu nachtverlagings
temperatuur om de temperatuur van de kamer tijdens de nachtverlaging 1
tot 10°C lager in te stellen.
5.3 Instellingen
In het opstartscherm kiest u:
Menu
Instellingen
112
Handleiding CF-RC Afstandsbediening
VI.UH.M5.1C Geproduceerd door Danfoss Floor Heating Hydronics 08.2009
Kies het menu Instellingen om diverse gegevens en instelmogelijkheden
voor de afstandsbediening en voor het volledige CF2-systeem te openen.
Opmerking: wijzigingen in het menu instellingen, kunnen een invloed hebben op de con-
guratie van het volledige CF2-systeem. Ga hier dus voorzichtig mee om!!
Talen:
Hier kunt u een andere taal kiezen dan de taal die tijdens het installatieproces
is geselecteerd (zie 2).
Datum en tijd:
Hier kunnen de datum en de tijd worden ingesteld. Bovendien omvat dit menu
de instellingen voor, en de activering van, het zomertijdprogramma. Hierdoor
kunt u instellen op welke dag, week en maand de zomertijd start en eindigt.
Alarm:
In dit menu kunt u de zoemer van de regelaar aan/uit zetten. Het geluid weer-
klinkt alleen bij een alarm, dat ook wordt aangegeven door de rode alarm-led
op de regelaar (zie g. 3- ). In het Alarmlog kunt u specieke informatie krijgen
over de fout en het tijdstip van het alarm. Het Alarmlog slaat de laatste alar-
men op, zodat die later kunnen worden bekeken en systeemfouten gemakke-
lijk kunnen worden geïdentificeerd.
Opstartvenster:
Hier kunt u kiezen welke ruimtetemperatuur u in het opstartvenster wilt laten
weergeven.
Service:
In het menu Uitgangconguratie kunt u alle uitgangen van de regelaar (zie g.
5-a) configureren voor een systeem met vloerverwarming en/of radiatoren. Bij
vloerverwarming kunt u kiezen uit een regeling door middel van een Aan/Uit-
of PPM- (Pulse Pauze Modulatie) principe. Wanneer voor een radiatorsysteem
wordt gekozen, wordt de regeling automatisch ingesteld op PPM. Er kan zelfs
worden gekozen voor een gemengd systeem met een vloer- en radiatorver-
Handleiding CF-RC Afstandsbediening
VI.UH.M5.1C Geproduceerd door Danfoss Floor Heating Hydronics 08.2009
113
NL
warming in afzonderlijke ruimtes, door de uitgangen van de regelaar
voor elke ruimte individueel in te stellen op vloer- of radiatorverwarming.
Opmerking: wanneer een uitgang PPM wordt geregel, dan zijn de cyclustijden:
Vloerverwarming: 2 uur
Radiatorverwarming: 15 minuten.
In het menu Service activeert u de functie Standby temperatuur door de OK
toets in te drukken om voor alle kamerthermostaten een vaste kamertempe-
ratuur tussen 5 en 35°C in te stellen wanneer de algemene stand-by ingang
op de regelaar wordt geactiveerd (zie instructie voor de regelaar, CF-MC voor
details over de installatie).
Contrast:
Hier kunt u het contrast van het display op de afstandsbediening aanpassen.
Verbindingstest:
Activeert een verbindingstest met de regelaar om de draadloze verbinding
van en naar de afstandsbediening (zie 3) te testen.
Regelaar identificeren:
Met deze functie kunt u een specieke regelaar identiceren in een systeem
van maximaal drie regelaars. Wanneer deze functie geactiveerd is, zal de rege-
laar waarvan u de identiteit wilt kennen, alle uitgang- led’s verschillende keren
van 1 tot 10 en terug laten knipperen, voor een gemakkelijke identicatie.
114
Handleiding CF-RC Afstandsbediening
VI.UH.M5.1C Geproduceerd door Danfoss Floor Heating Hydronics 08.2009
5.4 Alarmmeldingen
Indien in het CF2-syteem een alarm optreedt, dan wordt dit op de regelaar en
op het display van de afstandsbediening aangegeven:
Wanneer het alarm wordt bevestigd met de OK toets dan zal de zoemer van de
regelaar uitgaan (indien ingesteld op Geluid Aan, zie 5.3) en zal het CF2-systeem
overschakelen naar de Alarmstatus, zoals weergegeven in het opstartvenster:
Deze Alarm-aanduiding op de afstandsbediening en de aanduiding op de
regelaar zal zichtbaar blijven tot de fout die het alarm heeft veroorzaakt, is
opgelost.
Handleiding CF-RC Afstandsbediening
VI.UH.M5.1C Geproduceerd door Danfoss Floor Heating Hydronics 08.2009
115
NL
Een Alarm-menu wordt zichtbaar in het opstartvenster:
Door dit Alarm-menu met de Ok toets te activeren, wordt naar een Alarmsta-
tus gegaan waar u een beschrijving krijgt van de fout die het alarm heeft ver-eft ver-
oorzaakt. Bovendien kunt u het Alarmlog selecteren om specieke informatie
te krijgen over de fout die het alarm heeft veroorzaakt en het tijdstip voor de
registratie door het systeem. Dit Alarmlog slaat de laatste alarmen op, zodat
die later kunnen worden bekeken en systeemfouten gemakkelijk kunnen wor-
den geïdenticeerd. Wanneer er geen fouten zijn die een alarm veroorzaken,
dan kunt u het Alarmlog openen via het menu Instelling (zie 5.3).
6. Resetten
Resetten van de afstandbediening CF-RC – g. 1:
• Activeer tegelijkertijd keuzetoets , keuze toets en de toets omlaag’ .
• De afstandbediening vraagt een bevestiging alvorens te resetten.
Het bevestigen met “ja” reset de afstandbediening.
• Door de reset te bevestigen met “ja”, is de afstandbediening klaar voor
aanmelding op een regelaar CF-MC.
Opmerking: Lees de handleiding van de regelaar voor meer details!
116
Handleiding CF-RC Afstandsbediening
VI.UH.M5.1C Geproduceerd door Danfoss Floor Heating Hydronics 08.2009
7. Andere producten voor het CF2-systeem en
afkortingen
Andere producten voor het CF2-systeem – fig. 5
a) Regelaar, CF-MC: MC
b) Kamerthermostaat, CF-RS, -RD, -RP en –RF: KT
c) Signaalversterker, CF-RU: RU
8. Specificaties
Kabellengte (voeding) 1,8m
Zendfrequentie 868,42 MHz
Zendbereik in gebouwen (max.) 30m
Maximaal aantal signaalversterkers in serie 3
Zendvermogen < 1mW
Voedingspanning 230 V AC
Omgevingstemperatuur 0-50°C
IP-klasse 21
Handleiding CF-RC Afstandsbediening
VI.UH.M5.1C Geproduceerd door Danfoss Floor Heating Hydronics 08.2009
117
NL
9. Probleemoplossing
Foutmelding Mogelijke oorzaken
Motor/uitgang (E03) De uitgang van de regelaar of de motor die is aangeslo-
ten op deze uitgang, is kortgesloten of losgekoppeld.
Te lage temperatuur
(E05)
De temperatuur in de ruimte is lager dan 5°C.
(Probeer de werking van de kamerthermostaat te con-staat te con-
troleren door een verbindingstest uit te voeren).
Verbinding met regelaar
(E12)
De kamerthermostaat in de aangegeven ruimte heeft
geen draadloze verbinding met de regelaar meer.
Batterij bijna leeg in
Kamert. (E13)
Het batterijniveau van de kamerthermostaat voor de
aangegeven ruimte is te laag en de batterijen moeten
worden vervangen.
Batterijniveau in kamer-
thermostaat kritiek (E14)
Het batterijniveau van de kamerthermostaat voor de
aangegeven ruimte is kritisch laag en de batterijen
moeten zo snel mogelijk worden vervangen.
Verbinding tussen
regelaars (E24)
De aangegeven regelaars hebben geen draadloze
verbinding meer.
Het niveau in de batterijen van de afstandsbediening is
te laag en de batterijen moeten worden vervangen.
118
VI.UH.M5.1C Produced by Danfoss Floor Heating Hydronics 08.2009
Istruzioni Regolatore a distanza CF-RC
VI.UH.M5.1C Prodotto da Danfoss Floor Heating Hydronics 08.2009
119
I
I
Indice
10. Figure e illustrazioni ............................................................ A1-A2
1. Panoramica funzioni .................................................................. 120
2. Installazione ............................................................................... 120
3. Test di trasmissione ................................................................... 122
4. Montaggio ................................................................................... 122
5. Menù ........................................................................................... 123
5.1 Locali ........................................................................................................................... 123
5.2 Programma ............................................................................................................... 125
5.3 Setup ........................................................................................................................... 129
5.4 Allarmi ......................................................................................................................... 131
6. Disinstallazione .......................................................................... 132
7. Altri prodotti per il sistema CF2 e abbreviazioni .................... 133
8. Specifiche .................................................................................... 133
9. Ricerca guasti .............................................................................. 134
120
Istruzioni Regolatore a distanza CF-RC
VI.UH.M5.1C Prodotto da Danfoss Floor Heating Hydronics 08.2009
1. Panoramica funzioni
Parte anteriore – fig. 1
Display
Tasto programmabile 1
Tasto programmabile 2
Selettore su/giù
Selettore destra/sinistra
Icona per allarme sistema
Icona per comunicazione con Regolatore principale
Icona per la commutazione sull’alimentazione a 230 V
Icona per livello di carica delle batterie basso
Nota: Il Regolatore a distanza è provvisto di una struttura a menù autoguidata e tutte le im-
postazioni si possono eseguire con facilità grazie ai selettori su/giù e destra/sinistra in com-
binazione con le funzioni dei tasti programmabili, visualizzate sul display, sopra gli stessi.
Parte posteriore – fig. 2
Piastra posteriore/docking station
Vano batterie
Foro vite per montaggio a parete
Vite e tassello
Trasformatore/spina d’ alimentazione
Nota: Togliere la striscia di protezione per collegare le batterie fornite.
2. Installazione
Nota:
Installare il Regolatore a distanza dopo aver proceduto all’installazione di tutti
i Termostati ambiente, vedere la g. 5 b
Togliere la striscia di protezione per collegare le batterie fornite
Istruzioni Regolatore a distanza CF-RC
VI.UH.M5.1C Prodotto da Danfoss Floor Heating Hydronics 08.2009
121
I
Eettuare l’assegnazione del Regolatore a distanza al Regolatore principale entro una
distanza di 1½ m
Quando la retroilluminazione del display è spenta, basta il tocco di un solo pulsante per
riattivarla
Attivare la modalità d’ installazione sul Regolatore principale – fig. 3
Utilizzare il pulsante di selezione menù per selezionare la modalità d
installazione. Il LED d’ installazione lampeggia
Attivare la modalità d’ installazione premendo OK . Il LED d’ installazione
si accende a luce fissa
Attivare la modalità d’ installazione sul Regolatore a distanza - fig. 1
Una volta collegate le batterie, seguire la guida d installazione, iniziando con
la selezione della lingua
Terminato il processo d’ installazione, impostare l’ora e la data. Utilizzare il se-
lettore su/giù ed il selettore destra/sinistra per eseguire l impostazioni.
Confermare l impostazioni con OK attivato dal pulsante programmabile 1 ( )
Il processo d’ installazione si conclude con la possibilità d’ attribuire un nome
ai locali in cui sono sistemati i Termostati ambiente. Questo facilita notevol-
mente l’accesso al sistema ed il suo impiego
Nel menù Nomi locali, attivare il menù modica con il tasto programmabile
2 ( ) per modicare i nomi di default dei locali da, per esempio, MC1 Output
1.2 (Regolatore principale 1, uscita 1 e 2) a soggiorno e confermare con OK. Si
può utilizzare anche il menù scrivi….per creare altri nomi.
122
Istruzioni Regolatore a distanza CF-RC
VI.UH.M5.1C Prodotto da Danfoss Floor Heating Hydronics 08.2009
3. Test di trasmissione
Far partire un test di trasmissione sul Regolatore a distanza
Dalla videata d’ avvio, attivare il:
Menù
Setup
Test di collegamento
menù Test di collegamento per attivare un test della trasmissione radio tra il
Regolatore principale ed il Regolatore a distanza. Lo stato del test di collega-
mento viene visualizzato non appena il test stesso è stato eseguito.
Se il test di collegamento dà esito negativo:
Provare a cambiare la posizione nel locale del Regolatore a distanza
Oppure installare un Ripetitore (CF-RU, vedere la g. 5 c) e posizionarlo tra il
Regolatore principale ed il Regolatore a distanza
Nota: Il test di collegamento può anche richiedere alcuni minuti, in funzione delle dimensio-
ni del sistema
4. Montaggio
Il Regolatore a distanza è stato installato – fig. 2
Una volta che il Regolatore a distanza è stato installato sul Regolatore prin-
cipale (vedere 2), si può montarlo a parete per mezzo della piastra posterio-
re/docking station (1). In questo modo è possibile collegare il Regolatore a
distanza con un’alimentazione da 230 V con il trasformatore/spina di alimen-
Istruzioni Regolatore a distanza CF-RC
VI.UH.M5.1C Prodotto da Danfoss Floor Heating Hydronics 08.2009
123
I
tazione (5) inclusi. Quando non si trova nella docking station, il Regolatore a
distanza viene alimentato da batterie AA alcaline da 1,5 V.
• Prima di sistemare la piastra posteriore/docking station sulla parete, vericare
la trasmissione al Regolatore principale dalla posizione desiderata eseguendo
un test di collegamento (vedere 3)
• Montare la piastra posteriore/docking station sulla parete utilizzando le viti
ed i tasselli
Collegare la docking station ad una presa di alimentazione a 230 V per
mezzo del trasformatore/spina di alimentazione
• Sistemare il Regolatore a distanza nella docking station
Nota: Per estendere la portata di trasmissione del sistema CF2 si possono installare in serie
no a tre Ripetitori – vedere la g. 4.
5. Menù
Nota: Quando la retroilluminazione del display è spenta, basta il tocco di un solo pulsante per
riattivarla.
5.1 Locali
Dalla videata d’ avvio, attivare il:
Menù
Locali
menù Locali per accedere ad un elenco di tutti i locali del sistema. Selezionare
il locale desiderato con OK per portarsi nella schermata relativa a detto locale.
Qui si possono trovare le informazioni relative alle temperature impostate ed
eettive:
124
Istruzioni Regolatore a distanza CF-RC
VI.UH.M5.1C Prodotto da Danfoss Floor Heating Hydronics 08.2009
: Indica che questo locale è incluso in un programma di temporizzazione
in corso (vedere 5.2)
: Indica che le batterie del Termostato ambiente si stanno esaurendo
: Indica che il valore impostato sul Termostato ambiente è al di là dei
limiti max/min impostati dal Regolatore a distanza
: Indica che la temperatura impostata è superiore alla temperatura eettiva
: Indica che la temperatura impostata è inferiore alla temperatura eettiva.
5.1.1 Opzioni
Dalla videata del locale si può attivare un menù Opzioni con accesso a parec-
chie opzioni per il locale:
Imposta temperatura:
Qui si può impostare e bloccare la temperatura impostata per il Termostato
ambiente. Il bloccaggio impedisce la regolazione della temperatura impostata
sul Termostato ambiente.
Imposta Min/Max:
Qui si possono impostare e bloccare la temperatura minima e massima per il
Termostato ambiente. Il bloccaggio impedisce la regolazione al di là di questi
valori limite sul Termostato ambiente.
Modifica nome del locale:
Qui si possono modificare i nomi dei locali sulla base di un elenco di possibili
nomi dei locali oppure utilizzare il menù scrivi..... per inserire altri nomi.
Imposta Min/Max a pavimento:
Qui si possono impostare e bloccare la temperatura superficiale a pavimento
minima e massima.
Disponibile soltanto per il Termostato ambiente con sensore a pavimento a raggi infrarossi CF-RF.
Riduzione temperatura:
Qui si può scegliere di ignorare il periodo di riduzione temperatura successivo
o in corso (vedere 5.2.2).
Istruzioni Regolatore a distanza CF-RC
VI.UH.M5.1C Prodotto da Danfoss Floor Heating Hydronics 08.2009
125
I
Raffreddamento:
Qui si può disabilitare la funzione di rareddamento per il locale in questione
Disponibile soltanto quando il Regolatore principale si trova in modalità rareddamento
5.2 Programma
Dalla videata d’ avvio, attivare il:
Menù
Programma
menù Programma per visualizzare le due opzioni di temporizzazione:
5.2.1 Programma periodo:
Con questo programma si può impostare la temperatura ambiente per tutti
i Termostati ambiente durante, ad esempio, una vacanza. La data d’ inizio e
di ne del programma si imposta facilmente su un calendario per mezzo dei
selettori su/giù e destra/sinistra (g. 1 – / ), confermando ciascuna impo-
stazione con OK. La temperatura ambiente e la durata del programma perio-
do sono illustrate e, inne, attivate da una panoramica particolareggiata del
programma creato:
126
Istruzioni Regolatore a distanza CF-RC
VI.UH.M5.1C Prodotto da Danfoss Floor Heating Hydronics 08.2009
5.2.2 Programma riduzione temperatura
Nel menù Programma riduzione temperatura si ha la possibilità di ripartire
i vari locali in un massimo di sei zone dierenti – ciascuna zona con no a tre
diversi programmi di riduzione temperatura per avere una temperatura am-
biente più bassa in momenti dierenti della giornata.
Opzioni:
Per ciascuna zona è prevista una videata che mostra i locali compresi nella
zona stessa. Questa fornisce l’accesso ad un menù Opzioni con una funzione
di Aggiungi locale e fino a tre Programmi riduzione temperatura.
Aggiungi locale:
In questo menù, tutti i locali sono seguiti da ( ) che indica a quale zona è stato
assegnato ogni locale (vedere la gura sottostante (1)). Per default tutti i locali
sono assegnati alla Zona 1. Se si creano zone nuove, i locali verranno spostati
dalla zona a cui sono assegnati alla nuova zona (dalla zona 1 alla zona 2 nella
figura sottostante).
Programma 1 – 3:
Il menù Opzioni comprende anche tre possibili programmi riduzione tempe-
ratura per ciascuna zona. Con questi i setti giorni della settimana si possono
ripartire in max tre diversi programmi riduzione temperatura, con giorni e pe-
riodi di riduzione temperatura dierenti per ogni programma. La procedura di
creazione o di modica di un programma è identica per tutti e tre i programmi.
Istruzioni Regolatore a distanza CF-RC
VI.UH.M5.1C Prodotto da Danfoss Floor Heating Hydronics 08.2009
127
I
Attivare il programma (1 – 3) dal menù Opzioni con OK per selezionare i
giorni per detto programma:
Utilizzare i selettori su/giù e destra/sinistra (g. 1- / ) per selezionare i giorni
del programma, spostandoli sopra la linea orizzontale. Confermare con OK e
attivare la fase successiva per selezionare l’orario del programma riduzione
temperatura.
Selezionare l’orario del programma riduzione temperatura impostando le
ore per i periodi duranti i quali si vuole una temperatura ambiente normale,
indicata dalle barre nere sopra la linea delle ore (i periodi al di fuori delle
barre nere sono i periodi a temperatura ambiente ridotta). Impostare gli orari
di inizio e di ne tramite il selettore destra/sinistra e passando dall’uno all’altro
per mezzo del selettore su/giù (g. 1- / ).
Si può eliminare il secondo pe-
riodo a temperatura ambiente
normale trasformando l’orario
di fine di questo periodo nel suo
orario di inizio:
128
Istruzioni Regolatore a distanza CF-RC
VI.UH.M5.1C Prodotto da Danfoss Floor Heating Hydronics 08.2009
Il secondo periodo a tempe-
ratura ambiente normale si
può aggiungere nuovamente
tramite il selettore su/giù e
passando per il primo periodo
.
Confermare i periodi di tempo selezionati con OK per attivare il programma
creato da questa panoramica:
Nota: I giorni selezionati nel programma sono indicati da lettere maiuscole più evidenziate
Cancella programma:
Un programma creato si può eliminare con il menù Cancella programma che
porta alla panoramica sopra riportata
Nota:
• Nel menù Opzioni, i programmi creati (1-3) saranno indicati da lettere maiuscole più
evidenziate
• Se si desidera ignorare un periodo di riduzione temperatura in un locale, lo si può fare con
la funzione Ignora riduzione temperatura nel menù Opzioni di ciascun locale (vedere
5.1.1)
Istruzioni Regolatore a distanza CF-RC
VI.UH.M5.1C Prodotto da Danfoss Floor Heating Hydronics 08.2009
129
I
Temperatura ridotta
Nel Programma riduzione temperatura (vedere 5.2.2), attivare il menù Tem-
peratura ridotta per impostare la riduzione della temperatura ambiente da 1
a 10°C durante i periodi di riduzione della stessa.
5.3 Setup
Dalla videata d’ avvio, attivare il:
Menù
Setup
menù Setup con l’accesso ad una serie di informazioni e di possibilità d impo-
stazione per il Regolatore a distanza e per l’intero sistema CF2.
Nota: Dal momento che alcune delle possibilità d’ impostazione del menù Setup possono
avere ripercussioni sulla congurazione del sistema CF2 – e, dunque, sul funzionamento
dell’intera applicazione in generale – è opportuno procedere con cautela
Lingue:
Qui si può selezionare una lingua dierente da quella scelta durante il proces-
so d’ installazione (vedere 2).
Data e ora:
Fornisce l’accesso allimpostazione della data e dell’ora. Questo menù, inoltre,
comprende le impostazioni relative al programma ora legale e la sua attivazio-
ne. Consente di congurare in quale giorno, settimana e mese inizia e nisce
l’ora legale.
Allarme:
Da questo menù si pinserire e disinserire il segnalatore sonoro del Regolatore
principale. Il suono si ha soltanto in caso d’ allarme, indicato anche dal LED d’
allarme rosso sul Regolatore principale (vedere la g. 3- ). Nel Log d’ allarme
130
Istruzioni Regolatore a distanza CF-RC
VI.UH.M5.1C Prodotto da Danfoss Floor Heating Hydronics 08.2009
si possono trovare informazioni speciche sull’errore che ha causato l’allarme
e l’orario di registrazione da parte del sistema. Questo Log d’ allarme salva gli
allarmi più recenti per consentirne l’accesso successivo e per una facile identi-
cazione dei guasti del sistema.
Videata di avvio:
Qui si può scegliere quale temperatura ambiente si desidera che venga visua-
lizzata nella videata d’ avvio.
Servizio:
Qui si possono congurare tutte le uscite del Regolatore principale (vedere la
fig. 5 a) per un sistema di riscaldamento a pavimento oppure tramite radia-
tori. Con il riscaldamento a pavimento si può scegliere la regolazione tutto o
niente o modulante (PWM). Selezionando un sistema a radiatori, si imposta
automaticamente la regolazione su “modulante (PWM). Si può selezionare
persino un sistema misto con riscaldamento a pavimento e tramite radiatori in
locali separati impostando le uscite del Regolatore principale individualmente
per ciascun locale su riscaldamento a pavimento o tramite radiatori.
Nota: Quando il Regolatore principale è a regolazione modulante (PWM), i tempi ciclo sono
i seguenti: Riscaldamento a pavimento: 2 ore
Riscaldamento mediante radiatori: 15 minuti.
Nel menù di Servizio, attivare la funzione Temperatura di standby con OK
per impostare una temperatura ambiente fissa per tutti i Termostati ambiente
su 5 – 35°C quando viene attivato sul Regolatore principale lingresso Standby
generale (vedere le istruzioni del Regolatore principale CF-MC per i particolari
d’ installazione).
Contrasto:
Qui si può regolare il contrasto del display del Regolatore a distanza.
Istruzioni Regolatore a distanza CF-RC
VI.UH.M5.1C Prodotto da Danfoss Floor Heating Hydronics 08.2009
131
I
Test di collegamento:
Attiva un test di collegamento con il Regolatore principale per verificare la
trasmissione radio verso e dal Regolatore a distanza (vedere 3).
Identifica il Regolatore principale:
Questa funzione consente di identicare un Regolatore principale specico in
un sistema di max tre Regolatori principali. Quando è attivata questa funzione,
il Regolatore principale di cui si vuole rivelare identità farà lampeggiare tutti i
LED d’ uscita dall’1 al 10 e viceversa parecchie volte per facilitare l’identicazione.
5.4 Allarmi
Se si verica un errore nel sistema CF2, è indicato dal Regolatore principale
e direttamente sul display del Regolatore a distanza:
Quando si acquisisce l’allarme con OK, il segnalatore sonoro del Regolatore
principale si spegne (se impostato su Suono inserito, vedere 5.3) e il sistema
CF2 passerà in Stato d’ allarme, come indicato sulla schermata d’ avvio:
132
Istruzioni Regolatore a distanza CF-RC
VI.UH.M5.1C Prodotto da Danfoss Floor Heating Hydronics 08.2009
Quest’ indicazione d’ Allarme sul Regolatore a distanza e l’indicazione sul Rego-
latore principale rimarranno nché non è stato corretto l’errore che ha causato
l’allarme.
Un menù Allarmi sarà presente in cima all’elenco dei menù, attivato partendo
dalla schermata d’ avvio:
Attivando questo menù Allarmi con OK si ha accesso ad uno Stato d’ allar-
me, dove si può vedere una descrizione dell’errore che ha causato l’allarme. Si
può selezionare, inoltre, il Log d’ allarme per ottenere informazioni speciche
sull’errore che ha provocato l’allarme e l’orario della sua registrazione da parte
del sistema. Questo Log d’ allarme salva gli allarmi più recenti per consentir-
ne l’accesso successivo e per una facile identicazione dei guasti del sistema.
Quando non c’è nessun errore che causa un allarme, si può accedere al Log d
allarme attraverso il menù di Setup (vedere 5.3).
6. Disinstallazione
Reset del Regolatore a distanza CF-RC – g. 1:
Attivare contemporaneamente il tasto programmabile 1 , il tasto program-
mabile 2 ed il selettore giù .
Il Regolatore a distanza richiede la conferma prima del reset. La conferma con
“sì” porta al reset del Regolatore a distanza.
Istruzioni Regolatore a distanza CF-RC
VI.UH.M5.1C Prodotto da Danfoss Floor Heating Hydronics 08.2009
133
I
Confermando il reset con sì”, il Regolatore a distanza è ora pronto per l’installa-
zione su un Regolatore principale CF-MC.
Nota: Vedere le istruzioni del Regolatore principale per ulteriori informazioni.
7. Altri prodotti per il sistema CF2 e abbreviazioni
Altri prodotti per il sistema CF2 – fig. 5
a) Regolatore principale, CF-MC: MC
b) Termostato ambiente, CF-RS, -RD, -RP i –RF: T. ambiente
c) Ripetitore, CF-RU: RU
8. Specifiche
Lunghezza cavo (alimentazione) 1,8 m
Frequenza di trasmissione 868,42 MHz
Portata di trasmissione in edici (no a) 30m
Numero di Ripetitori in serie (no a) 3
Potenza di trasmissione < 1mW
Tensione di alimentazione 230 V AC
Temperatura ambiente 0-50°C
Classe IP 21
134
Istruzioni Regolatore a distanza CF-RC
VI.UH.M5.1C Prodotto da Danfoss Floor Heating Hydronics 08.2009
9. Ricerca guasti
Indicazione d’ errore Cause possibili
Attuatore/uscita (E03) L’uscita del Regolatore principale (MC) o l’attuatore
collegato a questa uscita è cortocircuitato o scollegato
Temperatura bassa (E05) La temperatura nel locale è inferiore ai 5°C (cercare di
vericare il funzionamento del Termostato ambiente
eseguendo un test di collegamento partendo dallo
stesso)
Collegamento con il
Regolatore principale
(E12)
Il Termostato ambiente nel locale indicato ha perso il
collegamento radio con il Regolatore principale (MC)
Liv. batterie basso nel T.
ambiente (E13)
Il livello di carica delle batterie del Termostato ambiente
relativo al locale indicato è basso e vanno sostituite le
batterie stesse
Liv. batterie critico nel
T. ambiente (E14)
Il livello di carica delle batterie del Termostato ambiente
relativo al locale indicato è critico e vanno sostituite le
batterie stesse al più presto
Collegamento tra MC
(E24)
Il termostato ambiente nel locale indicato ha perso il
collegamento radio con il Regolatore principale (MC)
Il livello di carica delle batterie del Regolatore a distanza
è basso e vanno sostituite le batterie stesse
VI.UH.M5.1C Produced by Danfoss Floor Heating Hydronics 08.2009
135
GB
136
VI.UH.M5.1C Produced by Danfoss Floor Heating Hydronics 08.2009
Fig. 1 Fig. 2
A1
Fig. 4Fig. 3
Fig. 5
b)
c)
a)
A2
088N2464 | 01.08.2009 | Version 05
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141

Danfoss CF-RC Remote Controller Installatie gids

Type
Installatie gids