Inhoud
10. Afbeeldingen ............ .................................................................... A-B
1. Inleiding ..............................................................................................
54
2. Overzicht van het CF2-systeem – g. 1 .............................................
54
3. Functies overzicht – g. 2 ...................................................................
54
4. Montage ..............................................................................................
54
4.1 Wand ............................................................................................................................................54
4.2 DIN-rail ........................................................................................................................................54
5. Installatieprocedure (in volgorde) .................................................... 54
5.1 24 V-motoren ............................................................................................................................55
5.2 Relais voor pomp- en ketelsturing ....................................................................................55
5.3 Ingang voor algemene stand-by .......................................................................................55
5.4 Ingang voor verwarming en koeling................................................................................55
5.5 Bedrading ...................................................................................................................................56
5.6 Voeding .......................................................................................................................................56
5.7 Externe antenne (CF-EA) .......................................................................................................56
5.8 Meer (2-3) regelaars ................................................................................................................56
5.9 Andere systeemcomponenten ...........................................................................................56
5.10 Verbindingstest .....................................................................................................................57
6. Conguratie ........................................................................................ 57
6.1 Motoruitgangen ......................................................................................................................57
6.2 Relais voor pomp- en ketelsturing ....................................................................................57
6.3 Ingang voor algemene stand-by en verwarming & koeling ....................................58
6.4 Relais aansluitingen op meerdere (2-3) regelaars .......................................................58
7. Resetten / vervangen van de regelaar .............................................. 58
7.1 Wanneer? ....................................................................................................................................58
7.2 Hoe? .............................................................................................................................................59
8. Specicaties ........................................................................................ 59
9. Probleemoplossing ............................................................................
60
54
Handleiding CF-MC Regelaar
VI.UH.K6.1C Geproduceerd door Danfoss Floor Heating Hydronics 03.2007
1. Inleiding
De regelaar, CF-MC is een onderdeel van het nieuwe vooruitstrevende Danfoss
draadloze regelsysteem voor hydraulische vloerverwarming. De draadloze
tweeweg-communicatie garandeert een zeer hoge transmissiebetrouwbaarheid,
eenvoudige draadloze installatie, en een uitstekende individuele ruimteregeling
voor een optimaal comfort met zuinig energie gebruik.
Het Danfoss draadloze CF2 regelsysteem voor hydraulische vloerverwarming biedt
optimale betrouwbaarheid en uitgebreide functionaliteit, gecombineerd met een
ongeëvenaard installatie- en gebruikersgemak. Het omvat een regelaar, CF-MC,
met uitgangen die beveiligd zijn tegen kortsluiting, regeling door een AAN/UIT- of
PPM (Pulse Pauze Modulatie)-principe, algemene stand-by, afzonderlijke relais voor
pomp- en ketelsturing, zelftestprogramma en alarmmeldingen, mogelijkheid om
de draadloze verbinding (link) te testen op ieder type kamerthermostaat, ge-
makkelijke toegang tot het draadloze systeem en uitgebreide functionaliteit via de
optionele afstandsbediening, en de signaalversterker voor groter draadloos bereik.
2. Overzicht van het CF2-systeem – g. 1
a) Regelaar, CF-MC
b) Kamerthermostaten, CF-RS, -RP, -RD en -RF
c) Afstandsbediening, CF-RC
d) Signaalversterker, CF-RU
e) Externe antenne, CF-EA
3. Functies overzicht – g. 2
Menu keuze toets
Menu-led’s
Selectietoets voor uitgang en conguratie
OK-toets
Uitgang-led’s
Uitgangkabelbevestiging
Relais voor pomp en ketel
Ingang voor verwarmen/koelen (externe AAN/UIT-schakelaar)
Ingang voor algemene stand-by (8°C) (externe AAN/UIT-schakelaar)
Voeding (230 V)
Deksel opener
Aansluiting voor externe antenne
4. Montage
4.1 Wand
Verwijder het deksel (g. 3)
• Bevestig met schroeven en muurpluggen (g. 4)
4.2 DIN-rail
• Monteer de DIN-railonderdelen (g. 5)
• Op DIN-rail klikken (g. 6)
Van DIN-rail verwijderen (g. 7)
Opmerking: De regelaar moet horizontaal en rechtop worden gemonteerd.
5. Installatieprocedure (in volgorde)
Belangrijk: Werk eerst alle hieronder beschreven verbindingen op de regelaar af alvorens een
230 V-voeding aan te sluiten!
Handleiding CF-MC Regelaar
55
VI.UH.K6.1C Geproduceerd door Danfoss Floor Heating Hydronics 03.2007
NL
5.1 24 V-motoren
Sluit de draden van de motoren aan op de uitgangen (g. 8)
Bevestig de kabels
Ronde kabel (g. 9)
Vierkante/platte kabel (g. 10)
Opmerking: Als voor de AAN/UIT-sturing NC-motoren (normaal gesloten) worden geïnstalleerd,
dan is geen verdere conguratie van de motoruitgang nodig (zie 6.1)!
5.2 Relais voor pomp- en ketelsturing
Pomp: Sluit de fasedraad L (vanaf een externe 230V voeding) en de schakeldraad
aan op het pomprelais. Zorg er voor dat de voeding is uitgeschakeld. Voer ver-
volgens de aansluitingen op de pomp uit, in overeenstemming met de geldende
normen (g.11).
Zet de kabel vast (g. 12)
Ketel: Ketel: Dit warmtevraagkontakt kan (eventueel in serie met dat van een
weersafhankelijke regelaar) rechtstreeks aangesloten worden op de thermostaat-
aansluiting voor aan/uit schakelende thermostaten van de ketel. Raadpleeg ook de
documentatie van de ketelfabrikant.
Opmerking: Het relais voor pomp en ketel zijn potentiaalvrije contacten en kunnen dus NIET
worden gebruikt als directe voeding. Max. belasting is 230 V en 8 A/2 A (inductief)!
5.3 Ingang voor algemene stand-by
Verbind de twee draden van een externe schakelaar (AAN/UIT) met de twee aan-
sluitingen voor de algemene stand-by-ingang (g. 13).
Wanneer deze schakelaar gesloten is (AAN) zal het systeem het huidige instelpunt
voor alle kamerthermostaten negeren en het instellen op 8°C
Zet de kabel vast (g. 14).
Opmerking: De algemene stand-by verzekert een ingestelde kamertemperatuur van 8°C voor alle
kamerthermostaten, maar deze instelling kan worden gewijzigd met de afstandsbediening CF-RC.
5.4 Ingang voor verwarming en koeling
Verbind de twee draden van een externe schakelaar (AAN/UIT) met de twee
aansluitingen voor de verwarming- en koelingingang (g. 15).
Wanneer deze schakelaar gesloten (AAN) is, zal het systeem van de verwarming-
stand overschakelen op de koelingstand.
Zet de kabel vast (g. 16).
Opmerking: #1!
Wanneer het systeem in koelstand staat en de temperatuur in een kamer het ingestelde punt
overschrijdt, zal de motoruitgang worden geactiveerd (AAN bij NC-motoren/UIT bij NO-motoren)
Opmerking:#2!
Wanneer het systeem in koelstand werkt, moet een afzonderlijk dauwpuntalarm worden
geïnstalleerd.
Bij Danfoss zijn de hiervoor de volgende componenten te verkrijgen (zie voorbeeld
g. 17)
EDA-24V: Elektronisch Dauwpuntalarm – 088H3001
EDA-S: Dauwpuntsensor – 088H3011
TWA-A: 24 V-NO-motor – 088H3111
RA-C 20: Danfoss afsluiter* – 013G3096
* De keuze van deze afsluiter is afhankelijk van de dimensionering van het hydraulische systeem.
56
Handleiding CF-MC Regelaar
VI.UH.K6.1C Geproduceerd door Danfoss Floor Heating Hydronics 03.2007
5.5 Bedrading
5.6 Voeding
Wanneer alle motoren, pomp- en ketelsturingen en andere ingangen geïnstal-
leerd zijn, kunt u de voedingspanning van de regelaar aansluiten. (g. 18).
Opmerking: als de stekker van de voedingskabel wordt verwijderd, zorgt er dan voor dat de
nieuwe aansluiting gebeurt in overeenstemming met de geldende normen.
5.7 Externe antenne (CF-EA)
Opmerking: De externe antenne wordt geïnstalleerd als doorzendantenne wanneer GEEN trans-
missie mogelijk is door zware bouwconstructies of metalen barrières, bijv. als de regelaar zich in
een metalen kast bevindt.
Verwijder het plastic afdekplaatje van de antenneaansluiting op de regelaar.
(Fig. 19)
Sluit de externe antenne aan (Fig. 20).
Plaats de antenne aan de andere zijde van de transmissiebarrière, weg van
de regelaar.
5.8 Meer (2-3) regelaars (master met max. 2 slaves)
Opmerkingen: de pomp moet aangesloten worden op regelaar 1(master).
In één systeem kunnen maximaal 3 regelaars worden aangesloten.
Tijdens de aanmeldprocedure dient de afstand tussen de componenten max. 1,5 m
te zijn!
Activeer de aanmeld-installatiemode op regelaar 1 (master, g. 21)
Gebruik de menu keuze toets om de install mode te selecteren.
De led Install knippert.
Activeer de installatie mode door op de OK toets te drukken.
De led Install gaat branden.
Start de aanmelding-installatie op regelaar 2 of 3 (slave, g. 22)
Activeer de installatie (aanmelding) naar regelaar 1 (master) door op de OK toets
te drukken.
De led Install knippert tijdens de communicatie en dooft wanneer de installatie
afgerond is.
Monteer regelaar 2 en/of 3 op zijn eigen plaats, indien nodig. Bij het opnieuw
aansluiten op de 230V voeding zal de verbindingstest automatisch worden gestart.
Als regelaar 2 en/of 3 een eigen pomp heeft, dan moeten de relais voor pomp en
ketel in overeenstemming hiermee worden gecongureerd (zie 6.4).
Opmerking: de latere verwijdering van slave-regelaar 2 of 3 uit hoofd-regelaar 1 kan alleen
door hoofdregelaar 1 te resetten (zie 7.2).
5.9 Andere systeemcomponenten
Opmerking: De procedure voor de installatie (aanmelding) van andere systeemcomponenten op
de regelaar (kamerthermostaten, afstandsbediening en signaalversterker; zie 2) wordt beschreven
in de bijgevoegde handleiding voor deze systeemcomponenten. Raadpleeg deze handleidingen
voor de specieke installatieprocedures.
Handleiding CF-MC Regelaar
57
VI.UH.K6.1C Geproduceerd door Danfoss Floor Heating Hydronics 03.2007
NL
5.10 Verbindingstest
Opmerking: De verbindingstest tussen de regelaar en andere systeemcomponenten wordt
gestart vanaf de andere systeemcomponenten, zoals de kamerthermostaten, signaalversterker,
afstandsbediening enz.
Raadpleeg de handleiding die bij de betreende componenten word meegeleverd voor de proce-
dures van de verbindingstest.
Kamerthermostaten:
Wanneer de verbindingstest vanaf een kamerthermostaat wordt ontvangen door
de regelaar, dan zal/zullen de led’s op de toegewezen uitgang(en) knipperen.
Hierdoor kan worden bepaald aan welke uitgangen een kamerthermostaat werd
toegewezen (Fig. 23 - ).
6. Conguratie
6.1 Motoruitgangen
Activeren van de uitgangmode op een regelaar (g. 23)
Gebruik de menu keuze toets om de uitgangmode (Output) te selecteren. De
led Output knippert.
Activeer uitgang door op de OK toets te drukken. De led Output gaat
branden.
Kies de uitgangconguratie
Druk op de uitgangselectieknop en schakel tussen de mogelijke uitgang-
conguraties – de uitgang-led’s zullen branden – die hieronder worden
weergegeven:
Let op: Als er 5 leds branden is er een afstandsbediening aangemeld en is het
niet mogelijk om de instellingen van de regelaar te wijzigen.
1 led: De uitgangen worden gecongureerd met NC-motoren met
AAN/UIT-regeling (standaard)
2 led’s: De uitgangen worden gecongureerd met NO-motoren met
AAN/UIT-regeling (standaard)
3 led’s: De uitgangen worden gecongureerd met NC-motoren met
PPM-regeling (Pulse Pauze Modulatie) voor vloerverwarming
4 led’s: De uitgangen worden gecongureerd met NO-motoren met
PPM-regeling (Pulse Pauze Modulatie) voor vloerverwarming
5 led’s: Er is een afstandsbediening geïnstalleerd, het is niet mogelijk
om de instellingen te veranderen vanaf de regelaar.
Activeer de gekozen uitgangconguratie door op de OK toets te drukken.
Opmerking: In periodes zonder uitgangactiveringen zal de regelaar om de 2 weken een program-
ma voor afsluiterbediening uitvoeren dat tot 12 minuten duurt. Individuele uitgangsconguratie
is mogelijk met de afstandsbediening CF-RC, zie de betreende handleiding.
6.2 Relais voor pomp- en ketelsturing
Activeren van relaismode op de regelaar (g. 23)
Gebruik de menu keuze toets om Relaismode te selecteren.
De led Relay knippert.
Activeer door op de OK toets te drukken. De led Relay gaat branden.
Kies de relaisconguratie
Druk op de uitgangselectietoets en schakel tussen de mogelijke relaiscongu-
raties – de uitgang-led’s zullen branden – die hieronder worden aangegeven:
Geen led’s: De relais worden niet gebruikt
1 led: Alleen Pompsturing
58
Handleiding CF-MC Regelaar
VI.UH.K6.1C Geproduceerd door Danfoss Floor Heating Hydronics 03.2007
2 led’s: Alleen Ketelsturing
3 led’s: Pomp- en ketelsturing
4 led’s: Pompsturing met start/stopvertraging van 2 min.
5 led’s: Pomp- en ketelsturing met start/stopvertraging van 2 min. op de pomp
(standaard).
• Activeer gekozen relaisconguratie door op de OK toets te drukken.
Opmerking: Als het pomprelais actief is, zal de regelaar iedere 3e dag de pomp een minuut laten
draaien.
6.3 Ingang voor algemene stand-by en verwarming & koeling
Activeren ingangmode op de regelaar (g. 23)
Gebruik de menu keuze toets om ingangmode Input te selecteren.
De led Input knippert.
Activeer door op de OK toets te drukken. De led Input gaat branden.
Kies de ingangconguratie
Druk op de uitgangselectieknop en schakel tussen de mogelijke ingangscongu-
raties de uitgang-led’s zullen brandendie hieronder worden aangegeven:
1 led: de ingangpoorten worden niet gebruikt
2 led’s: de regelaar zal naar koeling overschakelen wanneer de ingang voor
verwarming/koeling geactiveerd is (doorverbonden, g. 2 - ).
3 led’s: de regelaar zal overschakelen naar een vast ingestelde kamertemperatuur
van 8°C voor alle kamerthermostaten wanneer de ingang voor algemene
stand-by geactiveerd is (doorverbonden, g. 2 - ).
4 led’s: De regelaar zal naar koeling overschakelen wanneer de ingang voor
verwarming/koeling geactiveerd is (g. 2 - ). In de verwarmingstand zal
de regelaar overschakelen naar een vast ingestelde kamertemperatuur
van 8°C voor alle kamerthermostaten wanneer de ingang voor algemene
stand-by geactiveerd is (g. 2 - ) (standaard).
Activeer de gekozen ingangconguratie door op de OK toets te drukken.
6.4 Relais aansluitingen op meerdere (2-3) regelaars
Opmerking: Als er in één systeem meerdere regelaars (slave)zijn verbonden met regelaar 1, dan
moeten de relais voor pomp- en ketel sturing afzonderlijk worden gecongureerd!
Activeer de relaismode op regelaar 2 / 3 (g. 23)
Gebruik de menu keuze toets om de relaismodus te selecteren.
De led Relay knippert.
Activeer de relaismode door op de OK toets te drukken. De led Relay gaat
branden.
Kies de relaisconguratie
Druk op de uitgangsselectieknop en schakel tussen de mogelijke relaiscongura-
ties – de uitgang-led’s zullen branden – die hieronder worden aangegeven:
Gebruikt pomp en ketel verbonden met regelaar 1:
Geen led’s: De relais worden niet gebruikt (standaard).
Als de verdeler en de pomp zich niet in dezelfde ruimte bevinden:
1 led: Pompsturing
4 led’s: Pompsturing met start/stopvertraging van 2 min.
Activeer de gekozen relaisconguratie door op de OK toets te drukken.
7. Resetten / vervangen van de regelaar
7.1 Wanneer?
Als de regelaar in een bestaand CF2-systeem wordt gereset naar de fabrieksin-
stellingen of wordt vervangen door een andere regelaar, dan moeten alle andere
Handleiding CF-MC Regelaar
59
VI.UH.K6.1C Geproduceerd door Danfoss Floor Heating Hydronics 03.2007
NL
componenten van het CF2-systeem eveneens worden gereset om ze te kunnen
herinstalleren op de geresette of vervangen regelaar CF-MC!
7.2 Hoe?
Opmerking: De regelaar mag alleen worden gereset naar de fabrieksinstellingen als de
normale installatie- en verwijderingprocedures niet gevolgd kunnen worden!
Resetten van de regelaar CF-MC – g. 23:
Koppel de 230V voeding los van de regelaar tot de led ‘Power gedoofd is.
Druk tegelijkertijd de menu keuze toets , de OK-toets en de uitgangsselectie-
toets in.
Sluit de 230V voeding weer aan op de regelaar en laat de drie toetsen pas los wan-
neer de led ‘Power’ en alle uitgang-led’s branden.
De regelaar is gereset wanneer alle uitgang-led’s uitgaan.
Resetten van de kamerthermostaten, CF-RS, -RP, -RD en -RF – g. 24:
Haal de kamerthermostaat van de muurplaat en koppel een van de batterijen los.
Druk de druktoets (verbindingstest) in en houd hem ingedrukt en sluit de batterij
weer aan.
• Laat de druktoets los wanneer de rode led aan en uit is gegaan.
De kamerthermostaat is nu gereset en klaar om te worden aangemeld op een
regelaar, CF-MC.
Resetten van de afstandsbediening CF-RC – g. 25:
Activeer tegelijkertijd keuze toets 1 , keuze toets 2 en de toets omlaag .
De afstandsbediening vraagt een bevestiging alvorens te resetten. Het bevestigen
met “ja reset de afstandsbediening.
Door de reset te bevestigen met “ja, is de afstandsbediening klaar voor aanmelding
op een regelaar, CF-MC.
Resetten van de signaalversterker CF-RU – g. 26:
Koppel de signaalversterker los van de 230 V-voeding.
Druk de keuzetoets (verbindingstest) in en houd hem ingedrukt.
Sluit de 230V voeding weer aan.
Laat de keuzetoets los wanneer de rode led aan en uit is gegaan.
De signaalversterker is nu gereset en klaar om te worden aangemeld op een
regelaar, CF-MC.
8. Specicaties
Zendfrequentie 868,42 MHz
Zendbereik In gewone gebouwen (max.) 30 m
Zendvermogen <1 mW
Voedingspanning 230 V AC
Motoruitgangen 10 x 24 V DC
Max. continue uitgangbelasting (totaal) 35 VA
Relais 230 V AC/8 (2) A
Omgevingstemperatuur 0-50°C
IP-klasse 30
60
Handleiding CF-MC Regelaar
VI.UH.K6.1C Geproduceerd door Danfoss Floor Heating Hydronics 03.2007
9. Probleemoplossing
Foutmelding Mogelijke oorzaken
Uitgang-led(‘s), alarm-led en
uitgangsmenu-led knipperen.
De zoemer weerklinkt*.
De uitgang of motor is kortgesloten of de motor is
losgekoppeld.
Uitgang-led(‘s), alarm-led en
ingangsmenu-led knipperen.
Zoemer AAN na 12 uur**
Geen draadloos signaal van kamerthermostaat
verbonden met deze uitgang(en) of de temperatuur
in de betreende kamer is lager dan 5°C. (Probeer
de werking van de kamerthermostaat te controleren
met een verbindingstest).
Uitgang-led’s 1-4, alarm-led en
ingang-led knipperen.
Geen signaal van de afstandsbediening
Uitgang-led’s 1-5, alarm-led en
ingangsmenu-led knipperen.
Geen signaal van regelaar #2 of #3 (slave)
* De zoemer wordt uitgeschakeld door de OK toets in te drukken. De foutmelding blijft tot de
fout is opgelost.
** Als het signaal van de kamerthermostaat verloren is, zal de regelaaruitgang elk uur gedurende
15 minuten worden geactiveerd om bevriezing te voorkomen, tot de fout verholpen is.

Documenttranscriptie

Handleiding CF-MC Regelaar NL Inhoud 1. Inleiding............................................................................................... 54 2. Overzicht van het CF2-systeem – fig. 1.............................................. 54 3. Functies overzicht – fig. 2.................................................................... 54 4. Montage............................................................................................... 54 4.1 Wand.............................................................................................................................................54 4.2 DIN-rail.........................................................................................................................................54 5. Installatieprocedure (in volgorde)..................................................... 54 5.1 24 V-motoren.............................................................................................................................55 5.2 Relais voor pomp- en ketelsturing.....................................................................................55 5.3 Ingang voor algemene stand-by........................................................................................55 5.4 Ingang voor verwarming en koeling................................................................................55 5.5 Bedrading....................................................................................................................................56 5.6 Voeding........................................................................................................................................56 5.7 Externe antenne (CF-EA)........................................................................................................56 5.8 Meer (2-3) regelaars.................................................................................................................56 5.9 Andere systeemcomponenten............................................................................................56 5.10 Verbindingstest......................................................................................................................57 6. Configuratie......................................................................................... 57 6.1 Motoruitgangen.......................................................................................................................57 6.2 Relais voor pomp- en ketelsturing.....................................................................................57 6.3 Ingang voor algemene stand-by en verwarming & koeling.....................................58 6.4 Relais aansluitingen op meerdere (2-3) regelaars........................................................58 7. Resetten / vervangen van de regelaar............................................... 58 7.1 Wanneer?.....................................................................................................................................58 7.2 Hoe?..............................................................................................................................................59 8. Specificaties......................................................................................... 59 9. Probleemoplossing............................................................................. 60 10. Afbeeldingen ................................................................................. A-B VI.UH.K6.1C Geproduceerd door Danfoss Floor Heating Hydronics 03.2007 53 NL Handleiding CF-MC Regelaar 1. Inleiding • De regelaar, CF-MC is een onderdeel van het nieuwe vooruitstrevende Danfoss draadloze regelsysteem voor hydraulische vloerverwarming. De draadloze tweeweg-communicatie garandeert een zeer hoge transmissiebetrouwbaarheid, eenvoudige draadloze installatie, en een uitstekende individuele ruimteregeling voor een optimaal comfort met zuinig energie gebruik. • Het Danfoss draadloze CF2 regelsysteem voor hydraulische vloerverwarming biedt optimale betrouwbaarheid en uitgebreide functionaliteit, gecombineerd met een ongeëvenaard installatie- en gebruikersgemak. Het omvat een regelaar, CF-MC, met uitgangen die beveiligd zijn tegen kortsluiting, regeling door een AAN/UIT- of PPM (Pulse Pauze Modulatie)-principe, algemene stand-by, afzonderlijke relais voor pomp- en ketelsturing, zelftestprogramma en alarmmeldingen, mogelijkheid om de draadloze verbinding (link) te testen op ieder type kamerthermostaat, gemakkelijke toegang tot het draadloze systeem en uitgebreide functionaliteit via de optionele afstandsbediening, en de signaalversterker voor groter draadloos bereik. 2. Overzicht van het CF2-systeem – fig. 1 a) Regelaar, CF-MC b) Kamerthermostaten, CF-RS, -RP, -RD en -RF c) Afstandsbediening, CF-RC d) Signaalversterker, CF-RU e) Externe antenne, CF-EA 3. Functies overzicht – fig. 2 Menu keuze toets Menu-led’s Selectietoets voor uitgang en configuratie OK-toets Uitgang-led’s Uitgangkabelbevestiging Relais voor pomp en ketel Ingang voor verwarmen/koelen (externe AAN/UIT-schakelaar) Ingang voor algemene stand-by (8°C) (externe AAN/UIT-schakelaar) Voeding (230 V) Deksel opener Aansluiting voor externe antenne 4. Montage 4.1 Wand • Verwijder het deksel (fig. 3) • Bevestig met schroeven en muurpluggen (fig. 4) 4.2 DIN-rail • Monteer de DIN-railonderdelen (fig. 5) • Op DIN-rail klikken (fig. 6) • Van DIN-rail verwijderen (fig. 7) Opmerking: De regelaar moet horizontaal en rechtop worden gemonteerd. 5. Installatieprocedure (in volgorde) Belangrijk: Werk eerst alle hieronder beschreven verbindingen op de regelaar af alvorens een 230 V-voeding aan te sluiten! 54 VI.UH.K6.1C Geproduceerd door Danfoss Floor Heating Hydronics 03.2007 Handleiding CF-MC Regelaar 5.1 24 V-motoren • Sluit de draden van de motoren aan op de uitgangen (fig. 8) • Bevestig de kabels Ronde kabel (fig. 9) Vierkante/platte kabel (fig. 10) Opmerking: Als voor de AAN/UIT-sturing NC-motoren (normaal gesloten) worden geïnstalleerd, dan is geen verdere configuratie van de motoruitgang nodig (zie 6.1)! 5.2 Relais voor pomp- en ketelsturing •P  omp: Sluit de fasedraad L (vanaf een externe 230V voeding) en de schakeldraad aan op het pomprelais. Zorg er voor dat de voeding is uitgeschakeld. Voer vervolgens de aansluitingen op de pomp uit, in overeenstemming met de geldende normen (fig.11). • Zet de kabel vast(fig. 12) •K  etel: Ketel: Dit warmtevraagkontakt kan (eventueel in serie met dat van een weersafhankelijke regelaar) rechtstreeks aangesloten worden op de thermostaataansluiting voor aan/uit schakelende thermostaten van de ketel. Raadpleeg ook de documentatie van de ketelfabrikant. Opmerking: Het relais voor pomp en ketel zijn potentiaalvrije contacten en kunnen dus NIET worden gebruikt als directe voeding. Max. belasting is 230 V en 8 A/2 A (inductief)! 5.3 Ingang voor algemene stand-by • Verbind de twee draden van een externe schakelaar (AAN/UIT) met de twee aan­ sluitingen voor de algemene stand-by-ingang (fig. 13). Wanneer deze schakelaar gesloten is (AAN) zal het systeem het huidige instelpunt voor alle kamerthermostaten negeren en het instellen op 8°C • Zet de kabel vast (fig. 14). Opmerking: De algemene stand-by verzekert een ingestelde kamertemperatuur van 8°C voor alle kamerthermostaten, maar deze instelling kan worden gewijzigd met de afstandsbediening CF-RC. 5.4 Ingang voor verwarming en koeling • Verbind de twee draden van een externe schakelaar (AAN/UIT) met de twee aansluitingen voor de verwarming- en koelingingang (fig. 15). Wanneer deze schakelaar gesloten (AAN) is, zal het systeem van de verwarmingstand overschakelen op de koelingstand. • Zet de kabel vast (fig. 16). NL Opmerking: #1! Wanneer het systeem in koelstand staat en de temperatuur in een kamer het ingestelde punt overschrijdt, zal de motoruitgang worden geactiveerd (AAN bij NC-motoren/UIT bij NO-motoren) Opmerking:#2! Wanneer het systeem in koelstand werkt, moet een afzonderlijk dauwpuntalarm worden geïnstalleerd. Bij Danfoss zijn de hiervoor de volgende componenten te verkrijgen (zie voorbeeld fig. 17) EDA-24V: Elektronisch Dauwpuntalarm – 088H3001 EDA-S: Dauwpuntsensor – 088H3011 TWA-A: 24 V-NO-motor – 088H3111 RA-C 20: Danfoss afsluiter* – 013G3096 * De keuze van deze afsluiter is afhankelijk van de dimensionering van het hydraulische systeem. VI.UH.K6.1C Geproduceerd door Danfoss Floor Heating Hydronics 03.2007 55 Handleiding CF-MC Regelaar 5.5 Bedrading Relais Ingang Algemene stand-by Motoruitgangen 1 Verwarming/ Koeling 2 3 4 5 6 7 8 9 10 Externe antenne LN LN 5.6 Voeding • Wanneer alle motoren, pomp- en ketelsturingen en andere ingangen geïnstalleerd zijn, kunt u de voedingspanning van de regelaar aansluiten. (fig. 18). Opmerking: als de stekker van de voedingskabel wordt verwijderd, zorgt er dan voor dat de nieuwe aansluiting gebeurt in overeenstemming met de geldende normen. 5.7 Externe antenne (CF-EA) Opmerking: De externe antenne wordt geïnstalleerd als doorzendantenne wanneer GEEN transmissie mogelijk is door zware bouwconstructies of metalen barrières, bijv. als de regelaar zich in een metalen kast bevindt. • Verwijder het plastic afdekplaatje van de antenneaansluiting op de regelaar. (Fig. 19) • Sluit de externe antenne aan (Fig. 20). • Plaats de antenne aan de andere zijde van de transmissiebarrière, weg van de regelaar. 5.8 Meer (2-3) regelaars (master met max. 2 slaves) Opmerkingen: de pomp moet aangesloten worden op regelaar 1(master). In één systeem kunnen maximaal 3 regelaars worden aangesloten. Tijdens de aanmeldprocedure dient de afstand tussen de componenten max. 1,5 m te zijn! Activeer de aanmeld-installatiemode op regelaar 1 (master, fig. 21) • Gebruik de menu keuze toets om de install mode te selecteren. De led Install knippert. •A  ctiveer de installatie mode door op de OK toets te drukken. De led Install gaat branden. Start de aanmelding-installatie op regelaar 2 of 3 (slave, fig. 22) •A  ctiveer de installatie (aanmelding) naar regelaar 1 (master) door op de OK toets te drukken. •D  e led Install knippert tijdens de communicatie en dooft wanneer de installatie afgerond is. •M  onteer regelaar 2 en/of 3 op zijn eigen plaats, indien nodig. Bij het opnieuw aansluiten op de 230V voeding zal de verbindingstest automatisch worden gestart. •A  ls regelaar 2 en/of 3 een eigen pomp heeft, dan moeten de relais voor pomp en ketel in overeenstemming hiermee worden geconfigureerd (zie 6.4). Opmerking: de latere verwijdering van slave-regelaar 2 of 3 uit hoofd-regelaar 1 kan alleen door hoofdregelaar 1 te resetten (zie 7.2). 5.9 Andere systeemcomponenten Opmerking: De procedure voor de installatie (aanmelding) van andere systeemcomponenten op de regelaar (kamerthermostaten, afstandsbediening en signaalversterker; zie 2) wordt beschreven in de bijgevoegde handleiding voor deze systeemcomponenten. Raadpleeg deze handleidingen voor de specifieke installatieprocedures. 56 VI.UH.K6.1C Geproduceerd door Danfoss Floor Heating Hydronics 03.2007 Handleiding CF-MC Regelaar 5.10 Verbindingstest Opmerking: De verbindingstest tussen de regelaar en andere systeemcomponenten wordt gestart vanaf de andere systeemcomponenten, zoals de kamerthermostaten, signaalversterker, afstandsbediening enz. Raadpleeg de handleiding die bij de betreffende componenten word meegeleverd voor de procedures van de verbindingstest. Kamerthermostaten: Wanneer de verbindingstest vanaf een kamerthermostaat wordt ontvangen door de regelaar, dan zal/zullen de led’s op de toegewezen uitgang(en) knipperen. Hierdoor kan worden bepaald aan welke uitgangen een kamerthermostaat werd toegewezen (Fig. 23 - ). 6. Configuratie 6.1 Motoruitgangen Activeren van de uitgangmode op een regelaar (fig. 23) •G  ebruik de menu keuze toets om de uitgangmode (Output) te selecteren. De led Output knippert. • Activeer uitgang door op de OK toets te drukken. De led Output gaat branden. Kies de uitgangconfiguratie • Druk op de uitgangselectieknop en schakel tussen de mogelijke uitgang­ configuraties – de uitgang-led’s zullen branden – die hieronder worden weergegeven: Let op: Als er 5 leds branden is er een afstandsbediening aangemeld en is het niet mogelijk om de instellingen van de regelaar te wijzigen. •1  led: De uitgangen worden geconfigureerd met NC-motoren met AAN/UIT-regeling (standaard) •2  led’s: De uitgangen worden geconfigureerd met NO-motoren met AAN/UIT-regeling (standaard) •3  led’s: De uitgangen worden geconfigureerd met NC-motoren met PPM-regeling (Pulse Pauze Modulatie) voor vloerverwarming •4  led’s: De uitgangen worden geconfigureerd met NO-motoren met PPM-regeling (Pulse Pauze Modulatie) voor vloerverwarming •5  led’s: Er is een afstandsbediening geïnstalleerd, het is niet mogelijk om de instellingen te veranderen vanaf de regelaar. •A  ctiveer de gekozen uitgangconfiguratie door op de OK toets NL te drukken. Opmerking: In periodes zonder uitgangactiveringen zal de regelaar om de 2 weken een programma voor afsluiterbediening uitvoeren dat tot 12 minuten duurt. Individuele uitgangsconfiguratie is mogelijk met de afstandsbediening CF-RC, zie de betreffende handleiding. 6.2 Relais voor pomp- en ketelsturing Activeren van relaismode op de regelaar (fig. 23) • Gebruik de menu keuze toets om Relaismode te selecteren. De led Relay knippert. • Activeer door op de OK toets te drukken. De led Relay gaat branden. Kies de relaisconfiguratie •D  ruk op de uitgangselectietoets en schakel tussen de mogelijke relaisconfiguraties – de uitgang-led’s zullen branden – die hieronder worden aangegeven: • Geen led’s: De relais worden niet gebruikt • 1 led: Alleen Pompsturing VI.UH.K6.1C Geproduceerd door Danfoss Floor Heating Hydronics 03.2007 57 Handleiding CF-MC Regelaar • 2 led’s: Alleen Ketelsturing • 3 led’s: Pomp- en ketelsturing • 4 led’s: Pompsturing met start/stopvertraging van 2 min. • 5 led’s: Pomp- en ketelsturing met start/stopvertraging van 2 min. op de pomp (standaard). • Activeer gekozen relaisconfiguratie door op de OK toets te drukken. Opmerking: Als het pomprelais actief is, zal de regelaar iedere 3e dag de pomp een minuut laten draaien. 6.3 Ingang voor algemene stand-by en verwarming & koeling Activeren ingangmode op de regelaar (fig. 23) •G  ebruik de menu keuze toets om ingangmode Input te selecteren. De led Input knippert. •A  ctiveer door op de OK toets te drukken. De led Input gaat branden. Kies de ingangconfiguratie •D  ruk op de uitgangselectieknop en schakel tussen de mogelijke ingangsconfiguraties – de uitgang-led’s zullen branden – die hieronder worden aangegeven: •1  led: de ingangpoorten worden niet gebruikt •2  led’s: de regelaar zal naar koeling overschakelen wanneer de ingang voor verwarming/koeling geactiveerd is (doorverbonden, fig. 2 - ). •3  led’s: de regelaar zal overschakelen naar een vast ingestelde kamertemperatuur van 8°C voor alle kamerthermostaten wanneer de ingang voor algemene stand-by geactiveerd is (doorverbonden, fig. 2 - ). •4  led’s: De regelaar zal naar koeling overschakelen wanneer de ingang voor verwarming/koeling geactiveerd is (fig. 2 - ). In de verwarmingstand zal de regelaar overschakelen naar een vast ingestelde kamertemperatuur van 8°C voor alle kamerthermostaten wanneer de ingang voor algemene stand-by geactiveerd is (fig. 2 - ) (standaard). •A  ctiveer de gekozen ingangconfiguratie door op de OK toets te drukken. 6.4 Relais aansluitingen op meerdere (2-3) regelaars Opmerking: Als er in één systeem meerdere regelaars (slave)zijn verbonden met regelaar 1, dan moeten de relais voor pomp- en ketel sturing afzonderlijk worden geconfigureerd! Activeer de relaismode op regelaar 2 / 3 (fig. 23) • Gebruik de menu keuze toets om de relaismodus te selecteren. De led Relay knippert. •A  ctiveer de relaismode door op de OK toets te drukken. De led Relay branden. gaat Kies de relaisconfiguratie • Druk op de uitgangsselectieknop en schakel tussen de mogelijke relaisconfiguraties – de uitgang-led’s zullen branden – die hieronder worden aangegeven: Gebruikt pomp en ketel verbonden met regelaar 1: •G  een led’s: De relais worden niet gebruikt (standaard). Als de verdeler en de pomp zich niet in dezelfde ruimte bevinden: •1  led: Pompsturing •4  led’s: Pompsturing met start/stopvertraging van 2 min. •A  ctiveer de gekozen relaisconfiguratie door op de OK toets te drukken. 7. Resetten / vervangen van de regelaar 7.1 Wanneer? •A  ls de regelaar in een bestaand CF2-systeem wordt gereset naar de fabrieksinstellingen of wordt vervangen door een andere regelaar, dan moeten alle andere 58 VI.UH.K6.1C Geproduceerd door Danfoss Floor Heating Hydronics 03.2007 Handleiding CF-MC Regelaar componenten van het CF2-systeem eveneens worden gereset om ze te kunnen herinstalleren op de geresette of vervangen regelaar CF-MC! 7.2 Hoe? Opmerking: De regelaar mag alleen worden gereset naar de fabrieksinstellingen als de normale installatie- en verwijderingprocedures niet gevolgd kunnen worden! Resetten van de regelaar CF-MC – fig. 23: •K  oppel de 230V voeding los van de regelaar tot de led ‘Power gedoofd is. • Druk tegelijkertijd de menu keuze toets , de OK-toets en de uitgangsselectie­ toets in. • S luit de 230V voeding weer aan op de regelaar en laat de drie toetsen pas los wanneer de led ‘Power’ en alle uitgang-led’s branden. •D  e regelaar is gereset wanneer alle uitgang-led’s uitgaan. Resetten van de kamerthermostaten, CF-RS, -RP, -RD en -RF – fig. 24: •H  aal de kamerthermostaat van de muurplaat en koppel een van de batterijen los. •D  ruk de druktoets (verbindingstest) in en houd hem ingedrukt en sluit de batterij weer aan. • Laat de druktoets los wanneer de rode led aan en uit is gegaan. •D  e kamerthermostaat is nu gereset en klaar om te worden aangemeld op een regelaar, CF-MC. Resetten van de afstandsbediening CF-RC – fig. 25: •A  ctiveer tegelijkertijd keuze toets 1 , keuze toets 2 en de toets ‘omlaag’ . •D  e afstandsbediening vraagt een bevestiging alvorens te resetten. Het bevestigen met “ja” reset de afstandsbediening. •D  oor de reset te bevestigen met “ja”, is de afstandsbediening klaar voor aanmelding op een regelaar, CF-MC. Resetten van de signaalversterker CF-RU – fig. 26: •K  oppel de signaalversterker los van de 230 V-voeding. •D  ruk de keuzetoets (verbindingstest) in en houd hem ingedrukt. Sluit de 230V voeding weer aan. • L aat de keuzetoets los wanneer de rode led aan en uit is gegaan. •D  e signaalversterker is nu gereset en klaar om te worden aangemeld op een regelaar, CF-MC. NL 8. Specificaties Zendfrequentie 868,42 MHz Zendbereik In gewone gebouwen (max.) 30 m Zendvermogen <1 mW Voedingspanning 230 V AC Motoruitgangen 10 x 24 V DC Max. continue uitgangbelasting (totaal) 35 VA Relais 230 V AC/8 (2) A Omgevingstemperatuur 0-50°C IP-klasse 30 VI.UH.K6.1C Geproduceerd door Danfoss Floor Heating Hydronics 03.2007 59 Handleiding CF-MC Regelaar 9. Probleemoplossing Foutmelding Mogelijke oorzaken Uitgang-led(‘s), alarm-led en uitgangsmenu-led knipperen. De zoemer weerklinkt*. De uitgang of motor is kortgesloten of de motor is losgekoppeld. Uitgang-led(‘s), alarm-led en ingangsmenu-led knipperen. Zoemer AAN na 12 uur** Geen draadloos signaal van kamerthermostaat verbonden met deze uitgang(en) of de temperatuur in de betreffende kamer is lager dan 5°C. (Probeer de werking van de kamerthermostaat te controleren met een verbindingstest). Uitgang-led’s 1-4, alarm-led en ingang-led knipperen. Geen signaal van de afstandsbediening Uitgang-led’s 1-5, alarm-led en ingangsmenu-led knipperen. Geen signaal van regelaar #2 of #3 (slave) * De zoemer wordt uitgeschakeld door de OK toets in te drukken. De foutmelding blijft tot de fout is opgelost. ** Als het signaal van de kamerthermostaat verloren is, zal de regelaaruitgang elk uur gedurende 15 minuten worden geactiveerd om bevriezing te voorkomen, tot de fout verholpen is. 60 VI.UH.K6.1C Geproduceerd door Danfoss Floor Heating Hydronics 03.2007
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74

Danfoss CF-MC Master Controller Installatie gids

Type
Installatie gids