Gallagher 3E4410 M350 M550 M650 Energizer User Manual
7
• If connec ng leads and electric animal fence wires are installed near an overhead power
line, their height above the ground shall not exceed 3 m.
This height applies either side of the orthogonal projec on of the outermost conductors
of the power line on the ground surface, for a distance of:-
• 2 m for power lines opera ng at a nominal voltage not exceeding 1 000 V;
• 15 m for power lines opera ng at a nominal voltage exceeding 1 000 V.
• Electric animal fences intended for deterring birds, household pet containment or
training animals such as cows need only be supplied from low output energizers to
obtain sa sfactory and safe performance.
• In electric animal fences intended for deterring birds from roos ng on buildings, no
electric fence wire shall be connected to an earth stake. A warning sign shall be fi ed
to every point where persons may gain ready access to the conductors.
• Where an electric animal fence crosses a public pathway, a non-electrifi ed gate shall be
incorporated in the electric animal fence at that point or a crossing by means of s les
shall be provided. At any such crossing, the adjacent electrifi ed wires shall carry warning
signs.
• Any part of an electric animal fence that is installed along a public road or pathway
shall be iden fi ed by electric fence warning signs (G6020) at regular intervals that are
securely fastened to the fence posts or fi rmly clamped to the fence wires.
• The size of the warning sign shall be at least 100mm x 200mm.
• The background colour of both sides of the warning sign shall be
yellow. The inscrip on on the sign shall be black and shall be either:
• the substance of “CAUTION: Electric Fence” or,
• the symbol shown:
• The inscrip on shall be indelible, inscribed on both sides of the
warning sign and have a height of at least 25mm.
• Ensure that all mains operated, ancillary equipment connected to the electric animal
fence circuit provides a degree of isola on between the fence circuit and the supply
mains equivalent to that provided by the energizer.
• Protec on from the weather shall be provided for the ancillary equipment unless this
equipment is cer fi ed by the manufacturer as being suitable for use outdoors, and is of
a type with a minimum degree of protec on IPX4.
The author thanks the Interna onal Electrotechnical Commission (IEC) for permission to reproduce
Informa on from its Interna onal Publica on 60335-2-76 ed.2.2 (2013). Annex BB-1. All such extracts
are copyright of IEC, Geneva, Switzerland. All rights reserved. Further informa on on the IEC is available
from www.iec.ch. IEC has no responsibility for the placement and context in which the extracts and
contents are reproduced by the author, nor is IEC in any way responsible for the other content or
accuracy therein. Save these instrucƟ ons.