688018-218 G22NE 12
CLEANING AND MAINTENANCE:
Step 1: After usage, the device must first be switched OFF, after which you must remove the
plug from the socket. Always do this in the order described to prevent short circuit
or other possible dangers.
Step 2: Wait until the device has cooled down completely.
Step 3: Push on the black cap of the tap and turn it a quarter to let the oil run out of the
basin.
Step 4: Remove the grid (nr. 3).
Step 5: Clean the in- and outside of the device with a wet cloth and a small amount of
cleaning-detergent and then dry it thoroughly. Do not use benzine, thinner, scouring
brush or polishing powder to clean the induction fryer.
Pay attention! Do not rinse the device with water. (Don’t wash it by using the tap).
This could cause damage to the device and could therefore lead to dangerous
situations.
Never clean the device with a stainless steel brush.
This causes scratches and damages the device.
Use a vacuum cleaner to (gently) remove dirt and debris from the air-ventilation-grille.
Always store the fryer inside and keep it dry.
ERROR CODES
Display information
for control panel Possible cause Possible solution
Red light flashes once every
4 seconds Insulated Gate Bipolar
Transistor on the PCB is
overheated.
1. Switch the appliance off, let it cool
down.
2. Check the filter and clean if
necessary.
3. Make sure there’s enough space
around the fryer.
4. Switch appliance on again
5. If the error code remain display,
please contact supplier for repairing.
Red light flashes twice every
4 seconds Heating without any oil inside
the tank.
1. Switch the appliance off and let it
cool down.
2. Then fill the oil inside and switch on
again.
3. If the error code remain display,
please contact supplier for repairing.
Red light flashes three times
every 4 seconds The input voltage is above
265V or below 135V
Have an electrician check the input
voltage. If the input voltage is normal
and the error code remain display,
please contact the dealer for repairing.
Red light flashes four times
every 4 seconds The oil temperature sensor is in
short ciruit or open circuit. The appliance is overheated. Let it cool
down. Call the supplier to repair.
Red and green lights flash
together once every 4 seconds The heating coil sensor is short
circuit. The appliance is overheated. Let it cool
down. Call the supplier to repair.
Red and green lights flash
together twice every 4 seconds The heating coil sensor is open
circuit. The appliance is overheated. Let it cool
down. Call the supplier to repair.
Red and green lights flash
together three times every
4 seconds
The oil temperature is too
high and exceed the safety
temperature.
The appliance is overheated. Let it cool
down. Call the supplier to repair.