Fujifilm SonoSite X-Porte User Manual Supplement

Type
User Manual Supplement
rP19xp Transducer
User Guide Supplement
SonoSite, X-Porte, and the SonoSite logo are registered and unregistered trademarks of FUJIFILM SonoSite, Inc. in various jurisdictions.
Value from Innovation is a trademark of FUJIFILM Holdings America Corporation.
All other trademarks are the property of their respective owners.
Patents: US 9,151,832; US 8,956,296; US 8,861,822; US 8,834,372; US 8,805,047; US 8,355,554; US 8,216,146; US 8,213,467; US
8,137,278; US 8,088,071; US 8,066,642; US 7,804,970; US 7,740,586; US 7,604,596; US 7,449,640; US 7,169,108; US 6,962,566;
US 6,648,826; US 6,471,651; US 6,416,475; US 6,383,139; US 6,364,839; US 6,203,498; US 6,135,961; US 5,893,363; US
5,817,024; US 5,782,769; US 5,722,412; AU 727381; AU 730822; CA 2,371,711; CA 2,372,152; CN 103237499; CN 101231457;
CN 97113678.5; CN 98106133.8; CN 98108973.9; DE 60029777.2; DE 60034670.6; DE 69730563.5; DE 69830539.6; DE
69831698.3; EP 0815793; EP 0875203; EP 0881492; EP 1180971; EP 1180970; ES 0881492; ES 2229318; FR 0815793; FR
0875203; FR 0881492; FR 1180970; GB 0815793; GB 0875203; GB 0881492; GB 1180970; GB 1180971; IT 0815793; IT 0881492;
JP 5972258; JP 5782428; JP 4696150; KR 528102; KR 532359; NO 326814 and NO 326202.
Part number: P23130-01
Publication date: January 2017
Copyright © 2016 FUJIFILM SonoSite, Inc. All rights reserved.
Manufacturer
FUJIFILM SonoSite, Inc.
21919 30th Drive SE
Bothell, WA 98021 USA
T: 1-888-482-9449 or
1-425-951-1200
F: 1-425-951-1201
EC Authorized Representative
Emergo Europe
Molenstraat 15
2513 BH, The Hague
The Netherlands
Australia Sponsor
FUJIFILM SonoSite Australasia Pty Ltd
114 Old Pittwater Road
BROOKVALE, NSW, 2100
Australia
Caution United States federal law restricts this device to sale by or on the order of a
physician.
English Deutsch Español Fraais Italiano Portugs
Introduction 1
English Deutsch Español Français Italiano Português Nederlands
SonoSite X-Porte rP19xp Transducer User Guide
Supplement
Introduction ..................................................................................................................................................... 1
Document conventions ........................................................................................................................................................................... 1
Getting Help .................................................................................................................................................................................................. 2
Imaging modes ................................................................................................................................................ 3
Cleaning and disinfecting .............................................................................................................................. 4
Safety ............................................................................................................................................................... 4
Compatible accessories and peripherals ........................................................................................................................................ 5
Acoustic output .............................................................................................................................................. 5
Guidelines for reducing MI and TI ..................................................................................................................................................... 5
Output display ............................................................................................................................................................................................. 6
Acoustic output tables ............................................................................................................................................................................. 7
Introduction
This user guide supplement provides information on the rP19xp transducer, compatible with the SonoSite
X-Porte ultrasound system.
Document conventions
The document follows these conventions:
A WARNING describes precautions necessary to prevent injury or loss of life.
A Caution describes precautions necessary to protect the products.
A Note provides supplemental information.
Numbered and lettered steps must be performed in a specific order.
Bulleted lists present information in list format but do not imply a sequence.
For a description of labeling symbols that appear on the product, see "Labeling Symbols" in the ultrasound
system user guide.
2 Introduction
Getting Help
For technical support, please contact FUJIFILM SonoSite as follows:
Printed in the U.S.
Phone
(U.S. or Canada)
877-657-8118
Phone
(outside U.S. or
Canada)
425-951-1330, or call your local representative
Fax 425-951-6700
Email ffss-service@fujifilm.com
Web www.sonosite.com
Europe Service Center Main: +31 20 751 2020
English support: +44 14 6234 1151
French support: +33 1 8288 0702
German support: +49 69 8088 4030
Italian support: +39 02 9475 3655
Spanish support: +34 91 123 8451
Asia Service Center +65 6380-5581
English Deutsch Español Fraais Italiano Portugs
Imaging modes 3
English Deutsch Español Français Italiano Português Nederlands
Imaging modes
Table 1: Available exam types and imaging modes
Transducer Exam type
Imaging mode
2D
M Mode
Color
a
PW
Doppler
b
CW
Doppler
rP19xp Abdomen CVD, CPD
Cardiac CVD, Var
Lung CVD, CPD
Obstetrics CVD, CPD
Orbital CVD, CPD
Transcranial CVD, CPD
a
Var = Color Doppler Variance, which is available in the cardiac exam only. CPD = Color Power
Doppler, which is available in all exams except the cardiac exam type. CVD = Color Velocity Doppler.
b
For the cardiac exam type, PW TDI is also available.
Note The rP19xp transducer is needle guide-capable. For more information, refer to
Using CIVCO Products with FUJIFILM SonoSite Systems.
4 Cleaning and disinfecting
Cleaning and disinfecting
Safety
Table 2: Approved cleaners
Product Compatible transducer
Minimum wet contact time
a
SaniCloth AF3
b
rP19xp 3 minutes
PI-Spray II rP19xp 10 minutes
a
For maximum effectiveness, the component being cleaned must remain wet with disinfectant for a minimum
period of time.
b
Qualified for use as an intermediate-level disinfectant for mycobacteria.
Refer to the cleaners and disinfection document available at www.sonosite.com for a complete list of the most
current cleaners and disinfectants.
Table 3: Approved high-level compatible disinfectants
Disinfectant
a
Compatible transducer Temperature Disinfectant soak duration
Cidex rP19xp
25
o
C, 77
o
F
45 minutes
Cidex OPA rP19xp
20
o
C, 68
o
F
12 minutes
a
Refer to the cleaners and disinfection document available at www.sonosite.com for a complete list of the most
current cleaners and disinfectants.
WARNING To avoid device damage or patient injury, do not use the rP19xp needle-guide
bracket on patients with pacemakers or medical electronic implants. The needle-
guide bracket for rP19xp contains a magnet that is used to ensure that the bracket
is correctly oriented on the transducer. The magnetic field in direct proximity to the
pacemaker or medical electronic implant may have an adverse effect.
English Deutsch Español Fraais Italiano Portugs
Acoustic output 5
English Deutsch Español Français Italiano Português Nederlands
Compatible accessories and peripherals
Acoustic output
Guidelines for reducing MI and TI
Table 4: Accessories and peripherals
Description Maximum Cable Length
rP19xp transducer
a
6.0 ft /1.8 m
a
For transducers, maximum cable length is measured between the strain reliefs. The stated lengths do not include
the lengths of cable in the following locations: underneath the strain reliefs, inside the transducer enclosure, or inside
the transducer connector.
Table 5: Guidelines for reducing mechanical index (MI)
Transducer Depth
rP19xp
Decrease or lower setting of parameter to reduce MI.
Increase or raise setting of parameter to reduce MI.
6 Acoustic output
Output display
Table 6: Guidelines for reducing thermal index (TI)
Transducer
CPD Settings
PW
Settings
Box
Width
Box
Height
Box
Depth
PRF Depth Optimize
rP19xp
(PRF)
Decrease or lower setting of parameter to reduce TI.
Increase or raise setting of parameter to reduce TI.
Table 7: TI or MI 1.0
Transducer Index
2D/
M Mode
CPD/
Color
PW
Doppler
CW
Doppler
rP19xp MI Yes Yes Yes No
TIC, TIB, or TIS Yes Yes Yes Yes
Table 8: Transducer Surface Temperature Rise, External Use (°C )
Test rP19xp
Still air 15.8
Simulated use 8.8
English Deutsch Español Fraais Italiano Portugs
Acoustic output 7
English Deutsch Español Français Italiano Português Nederlands
Acoustic output tables
Table 9: Transducer Model: rP19xp Operating Mode: 2D
Index Label M.I.
TIS TIB
TIC
Scan
Non-scan
Non-scan
A
aprt
1 A
aprt
>1
Global Maximum Index Value 1.5 1.2 2.9
Associated Acoustic
Parameter
p
r.3
(MPa) 1.95
W
0
(mW) 120.0 190.8
min of [W
.3
(z
1
),I
TA.3
(z
1
)] (mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm)
z@PII
.3max
2.6
d
eq
(z
sp
) (cm)
F
c
(MHz) 1.72 2.02 1.80
Dim of A
aprt
X (cm) 1.92 1.92
Y (cm) 1.15 1.15
Other Information
PD (μsec) 1.227
PRF (Hz) 2933
p
r
@PII
max
(MPa) 2.30
d
eq
@Pll
max
(cm)
Focal Length FL
x
(cm) 3.42 3.42
FL
y
(cm) 9.00 9.00
I
PA.3
@MI
max
(W/cm
2
)
225
Operating
Control
Conditions
Control 1: Exam Type Crd Abd Abd
Control 2: Optimization Gen Pen Gen
Control 3: Depth 7 cm 5 cm 5 cm
Control 4: THI On Off On
Control 5: Sector Width Full N/A N/A
Data are not applicable for this transducer/mode.
8 Acoustic output
Table 10: Transducer Model: rP19xp Operating Mode: M Mode
Index Label M.I.
TIS TIB
TIC
Scan
Non-scan
Non-scan
A
aprt
1 A
aprt
>1
Global Maximum Index Value 1.5 1.1 0.9 3.0
Associated Acoustic
Parameter
p
r.3
(MPa) 1.95
W
0
(mW) 105 9.8 25.4 180.5
min of [W
.3
(z
1
),I
TA.3
(z
1
)] (mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm) 3.02
z@PII
.3max
2.6
d
eq
(z
sp
) (cm) 0.444
F
c
(MHz) 1.72 2.09 2.09 1.732 1.75
Dim of A
aprt
X (cm) 1.92 0.78 1.02 1.92
Y (cm) 1.15 1.15 1.15 1.15
Other Information
PD (μsec) 1.227
PRF (Hz) 2693
p
r
@PII
max
(MPa) 2.30
d
eq
@Pll
max
(cm) 0.427
Focal Length FL
x
(cm) 4.56 4.56 2.25
FL
y
(cm) 9.00 9.00 9.00
I
PA.3
@MI
max
(W/cm
2
)
225
Operating
Control
Conditions
Control 1: Exam Type Crd Abd Crd Abd
Control 2: Optimization Gen Pen Gen Gen
Control 3: Depth 7 cm 7 cm 13 cm 5 cm
Control 4: THI On Off On On
Data are not applicable for this transducer/mode.
English Deutsch Español Fraais Italiano Portugs
Acoustic output 9
English Deutsch Español Français Italiano Português Nederlands
Table 11: Transducer Model: rP19xp Operating Mode: Color/CPD
Index Label M.I.
TIS TIB
TIC
Scan
Non-scan
Non-scan
A
aprt
1 A
aprt
>1
Global Maximum Index Value 1.5 1.6 3.8
Associated Acoustic
Parameter
p
r.3
(MPa) 2.15
W
0
(mW) 134.3 174.1
min of [W
.3
(z
1
),I
TA.3
(z
1
)] (mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm)
z@PII
.3max
4.3
d
eq
(z
sp
) (cm)
F
c
(MHz) 2.05 2.60 2.09
Dim of A
aprt
X (cm) 1.34 0.63
Y (cm) 1.15 1.15
Other Information
PD (μsec) 1.662
PRF (Hz) 1526
p
r
@PII
max
(MPa) 2.91
d
eq
@Pll
max
(cm)
Focal Length FL
x
(cm) 4.56 2.25
FL
y
(cm) 9.00 9.00
I
PA.3
@MI
max
(W/cm
2
)
355
Operating
Control
Conditions
Control 1: Exam Type Lung OB Crd
Control 2: Mode CVD CVD CVD
Control 3: 2D Optimization/Depth Gen/
13 cm
Gen/
5 cm
Pen/
5 cm
Control 4: Sector Width/THI N/A N/A/Off Med/On
Control 5: Color Optimization/PRF Low/
273 Hz
High/
2841 Hz
High/
3571 Hz
Control 6: Color Box Position/Size Def/
Narrow
Bottom/
Small
Def/
Narrow
Data are not applicable for this transducer/mode.
10 Acoustic output
Table 12: Transducer Model: rP19xp Operating Mode: PW Doppler
Index Label M.I.
TIS TIB
TIC
Scan
Non-scan
Non-scan
A
aprt
1 A
aprt
>1
Global Maximum Index Value 1.5 1.9 4.0 3.2
Associated Acoustic
Parameter
p
r.3
(MPa) 2.17
W
0
(mW) 192.5 211.8
min of
[W
.3
(z
1
),I
TA.3
(z
1
)]
(mW) 108.3
z
1
(cm) 1.9
Z
bp
(cm) 2.5
Z
sp
(cm) 5.10
z@PII
.3max
0.5
d
eq
(z
sp
) (cm) 0.60
F
c
(MHz) 2.08 3.69 2.06 2.04
Dim of A
aprt
X (cm) 1.92 1.92 1.92
Y (cm) 1.15 1.15 1.15
Other Information
PD (μsec) 1.141
PRF (Hz) 1562
p
r
@PII
max
(MPa) 2.24
d
eq
@Pll
max
(cm) 0.54
Focal Length FL
x
(cm) 11.51 11.51
FL
y
(cm) 9.00 9.00
I
PA.3
@MI
max
(W/cm
2
)
156
Operating
Control
Conditions
Control 1: Exam Type Abd Crd Abd Abd
Control 2: Sample Volume Size 1 mm 7 mm 1 mm 1 mm
Control 3: Sample Volume Position Zone 0
(13 mm)
Zone7
(115 mm)
Zone 6
(96 mm)
Zone 7
(115 mm)
Control 4: PRF 1562 Hz 1008 Hz 1562 Hz 1562 Hz
Control 5: TDI Off On Off Off
Data are not applicable for this transducer/mode.
English Deutsch Español Fraais Italiano Portugs
Acoustic output 11
English Deutsch Español Français Italiano Português Nederlands
Table 13: Transducer Model: rP19xp Operating Mode: CW Doppler
Index Label M.I.
TIS TIB
TIC
Scan
Non-scan
Non-scan
A
aprt
1 A
aprt
>1
Global Maximum Index Value (a) 1.2 4.0 3.1
Associated Acoustic
Parameter
p
r.3
(MPa) #
W
0
(mW) 130.6 134.7 125.7
min of [W
.3
(z
1
),I
TA.3
(z
1
)] (mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm) 3.40
z@PII
.3max
#
d
eq
(z
sp
) (cm) 0.47
F
c
(MHz) # 2.00 2.00 2.00
Dim of A
aprt
X (cm) 0.90 0.90 0.72
Y (cm) 1.15 1.15 1.15
Other Information
PD (μsec) #
PRF (Hz) #
p
r
@PII
max
(MPa) #
d
eq
@Pll
max
(cm) 0.47
Focal Length FL
x
(cm) 22.01 1.30
FL
y
(cm) 9.00 9.00
I
PA.3
@MI
max
(W/cm
2
)
#
Operating
Control
Conditions
Control 1: Exam Type Crd Crd Crd
Control 2: Sample Volume Position Zone 11
(220 mm)
Zone 10
(189 mm)
Zone 0
(13 mm)
(a) This index is not required for this operating mode; value is <1.
# No data are reported for this operating condition since the global maximum index value is not reported for the
reason listed. (Reference Global Maximum Index Value line.)
Data are not applicable for this transducer/mode.
12 Acoustic output
Table 14: Transducer Model: rP19xp (Orbital use) Operating Mode: 2D
Index Label M.I.
TIS TIB
TIC
Scan
Non-scan
Non-scan
A
aprt
1 A
aprt
>1
Global Maximum Index Value 0.17 0.026 0.057
Associated Acoustic
Parameter
p
r.3
(MPa) 0.26
W
0
(mW) 2.35 3.88
min of [W
.3
(z
1
),I
TA.3
(z
1
)] (mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm)
z@PII
.3max
4.00
d
eq
(z
sp
) (cm)
F
c
(MHz) 2.34 2.33 2.34
Dim of A
aprt
X (cm) 1.92 1.92
Y (cm) 1.15 1.15
Other Information
PD (μsec) 0.59
PRF (Hz) 2317
p
r
@PII
max
(MPa) 0.45
d
eq
@Pll
max
(cm)
Focal Length FL
x
(cm) 16.77 16.77
FL
y
(cm) 9.00 9.00
I
PA.3
@MI
max
(W/cm
2
)
3.41
Operating
Control
Conditions
Control 1: Exam Type Orb Orb Orb
Control 2: Optimization Gen Gen Gen
Control 3: Depth 31 cm 31 cm 31 cm
Control 4: THI Off Off Off
Data are not applicable for this transducer/mode.
English Deutsch Español Fraais Italiano Portugs
Acoustic output 13
English Deutsch Español Français Italiano Português Nederlands
Table 15: Transducer Model: rP19xp (Orbital use) Operating Mode: M Mode
Index Label M.I.
TIS TIB
TIC
Scan
Non-scan
Non-scan
A
aprt
1 A
aprt
>1
Global Maximum Index Value 0.17 0.025 0.012 0.055
Associated Acoustic
Parameter
p
r.3
(MPa) 0.26
W
0
(mW) 1.848 0.84 3.68
min of [W
.3
(z
1
),I
TA.3
(z
1
)] (mW) 0.41
z
1
(cm) 2.80
Z
bp
(cm) 2.52
Z
sp
(cm) 3.8
z@PII
.3max
4.00
d
eq
(z
sp
) (cm) 0.85
F
c
(MHz) 2.34 2.37 2.37 2.34 2.37
Dim of A
aprt
X (cm) 1.92 1.92 1.92 1.92
Y (cm) 1.15 1.15 1.15 1.15
Other Information
PD (μsec) 0.59
PRF (Hz) 1600
p
r
@PII
max
(MPa) 0.45
d
eq
@Pll
max
(cm) 0.58
Focal Length FL
x
(cm) 14.0 14.0 14.0
FL
y
(cm) 9.0 9.0 9.0
I
PA.3
@MI
max
(W/cm
2
)
3.41
Operating
Control
Conditions
Control 1: Exam Type Orb Orb Orb Orb
Control 2: Optimization Gen Gen Gen Gen
Control 3: Depth 31 cm 25 cm 31 cm 25 cm
Control 4: THI Off Off Off Off
Data are not applicable for this transducer/mode.
14 Acoustic output
Table 16: Transducer Model: rP19xp (Orbital use) Operating Mode: Color/CPD
Index Label M.I.
TIS TIB
TIC
Scan
Non-scan
Non-scan
A
aprt
1 A
aprt
>1
Global Maximum Index Value 0.20 0.055 0.12
Associated Acoustic
Parameter
p
r.3
(MPa) 0.28
W
0
(mW) 5.55 5.77
min of
[W
.3
(z
1
),I
TA.3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm)
z@PII
.3max
0.4
d
eq
(z
sp
) (cm)
F
c
(MHz) 2.07 2.068 2.068
Dim of A
aprt
X (cm) 0.96 0.96
Y (cm) 1.15 1.15
Other Information
PD (μsec) 1.55
PRF (Hz) 6301
p
r
@PII
max
(MPa) 0.29
d
eq
@Pll
max
(cm)
Focal Length FL
x
(cm) 1.3 1.3
FL
y
(cm) 9.0 9.0
I
PA.3
@MI
max
(W/cm
2
)
2.58
Operating
Control
Conditions
Control 1: Exam Type Orb Orb Orb
Control 2: Mode CVD CVD CVD
Control 3: 2D Optimization/Depth Gen/5 cm Gen/
5
cm
Gen/
5
cm
Control 4: Color Optimization/PRF Med/
2778 Hz
Med/
2778 Hz
Med/
2778 Hz
Control 5: Color Box Position/Size Default/Top Default/
Top
Default/
Top
Data are not applicable for this transducer/mode.
English Deutsch Español Fraais Italiano Portugs
Acoustic output 15
English Deutsch Español Français Italiano Português Nederlands
Table 17: Transducer Model: rP19xp (Orbital use) Operating Mode: PW Doppler
Index Label M.I.
TIS TIB
TIC
Scan
Non-scan
Non-scan
A
aprt
1 A
aprt
>1
Global Maximum Index Value 0.19 0.22 0.56 0.51
Associated Acoustic
Parameter
p
r.3
(MPa) 0.28
W
0
(mW) 33.8 34.4
min of [W
.3
(z
1
),I
TA.3
(z
1
)] (mW) 21.89
z
1
(cm) 3.00
Z
bp
(cm) 2.52
Z
sp
(cm) 3.8
z@PII
.3max
0.8
d
eq
(z
sp
) (cm) 0.79
F
c
(MHz) 2.11 2.09 2.09 2.09
Dim of A
aprt
X (cm) 1.92 1.92 1.92
Y (cm) 1.15 1.15 1.15
Other Information
PD (μsec) 3.67
PRF (Hz) 3906
p
r
@PII
max
(MPa) 0.29
d
eq
@Pll
max
(cm) 0.69
Focal Length FL
x
(cm) 22.0 27.3
FL
y
(cm) 9.0 9.0
I
PA.3
@MI
max
(W/cm
2
)
2.43
Operating
Control
Conditions
Control 1: Exam Type Orb Orb Orb Orb
Control 2: Sample Volume Size 3 mm 9 mm 9 mm 7 mm
Control 3: Sample Volume Position Zone 1
(23 mm)
Zone 11
(220 mm)
Zone 11
(220 mm)
Zone 13
(273 mm)
Control 4: PRF 3906 Hz 2604 Hz 2604 Hz 1953 Hz
Data are not applicable for this transducer/mode.
16 Acoustic output
English Deutsch Español Français Italiano Português
Einführung 17
Nederlands
Ergänzung zum rP19xp-Schallkopf-Benutzer-
handbuch von SonoSite X-Porte
Einführung .................................................................................................................................................... 17
Dokumentkonventionen ...................................................................................................................................................................... 17
Weiterführende Informationen ......................................................................................................................................................... 18
Bildgebungsmodi ......................................................................................................................................... 19
Reinigung und Desinfektion ...................................................................................................................... 20
Sicherheit ..................................................................................................................................................... 20
Kompatible Zubehörteile und Peripheriegeräte ...................................................................................................................... 21
Schall-Ausgangsleistung ........................................................................................................................... 21
Richtlinien zur Reduzierung des MI und TI ................................................................................................................................ 21
Ausgangsleistungsanzeige ................................................................................................................................................................. 22
Schallausgangsleistungs-Tabellen .................................................................................................................................................. 23
Einführung
Diese Ergänzung zum Benutzerhandbuch enthält Informationen zum rP19xp-Schallkopf, der mit dem
SonoSite X-Porte-Ultraschallsystem kompatibel ist.
Dokumentkonventionen
Für das Dokument gelten folgende Konventionen:
Ein WARNHINWEIS beschreibt die notwendigen Vorsichtsmaßnahmen zur Vermeidung einer Verletzung
oder eines tödlichen Unfalls.
Ein Vorsichtshinweis beschreibt die notwendigen Vorsichtsmaßnahmen zum Schutz der Produkte.
Ein Hinweis enthält ergänzende Informationen.
Nummerierte oder mit Buchstaben versehene Schritte müssen in einer bestimmten Reihenfolge
durchgeführt werden.
Listen mit Gliederungspunkten stellen Informationen in einem Listenformat dar, schreiben jedoch keine
Reihenfolge vor.
Eine Beschreibung der Kennzeichnungssymbole des Produkts ist unter „Kennzeichnungssymbole“ im
Benutzerhandbuch des Ultraschallsystems zu finden.
18 Einführung
Weiterführende Informationen
Der technische Kundendienst von FUJIFILM SonoSite ist wie folgt erreichbar:
Gedruckt in den USA.
Telefon
(USA und Kanada)
+1-877-657-8118
Telefon
(außerhalb USA und
Kanada)
+1-425-951-1330, oder kontaktieren Sie Ihren Vertreter
vor Ort.
Fax +1-425-951-6700
E-Mail ffss-service@fujifilm.com
Web www.sonosite.com
Europäisches
Servicezentrum
Hauptstelle: +31 20 751 2020
Kundendienst auf Englisch: +44 14 6234 1151
Kundendienst auf Französisch: +33 1 8288 0702
Kundendienst auf Deutsch: +49 69 8088 4030
Kundendienst auf Italienisch: +39 02 9475 3655
Kundendienst auf Spanisch: +34 91 123 8451
Asiatisches
Servicezentrum
+65 6380-5581
English Deutsch Español Français Italiano Português
Bildgebungsmodi 19
Nederlands
Bildgebungsmodi
Tabelle 1: Verfügbare Untersuchungstypen und Bildgebungsmodi
Schallkopf
Untersu-
chungstyp
Bildgebungsmodus
2D
M Mode
Farbe
a
PW-
Doppler
b
CW-
Doppler
rP19xp Abdomen CVD, CPD
Herz CVD, Var
Lunge CVD, CPD
Geburtshilfe CVD, CPD
Orbital CVD, CPD
Transkraniell CVD, CPD
a
Var = Farb-Doppler-Varianz, ist nur beim Untersuchungstyp „Herz“ verfügbar. CPD = Farb-/
Amplituden-Doppler (CPD) ist bei allen Untersuchungstypen außer „Herz“ verfügbar. CVD = Farb-/
Geschwindigkeits-Doppler.
b
Beim Untersuchungstyp Herz ist auch PW TDI verfügbar.
Hinweis Der rP19xp-Schallkopf kann mit Nadelführung verwendet werden. Weitere
Informationen in Weitere Informationen in Using CIVCO Products with FUJIFILM
SonoSite Systems (Verwendung von CIVCO Produkten mit FUJIFILM SonoSite
Systemen).
20 Reinigung und Desinfektion
Reinigung und Desinfektion
Sicherheit
Tabelle 2: Zugelassene Reinigungsmittel
Produkt Kompatibler Schallkopf
Mindestzeit des Nasskontakts
a
SaniCloth AF3
b
rP19xp 3 Minuten
PI-Spray II rP19xp 10 Minuten
a
Um eine maximale Wirksamkeit zu erzielen, muss die zu reinigende Komponente eine Mindestzeit lang mit dem
Desinfektionsmittel benässt sein.
b
Geeignet zur Verwendung als Desinfektionsmittel mittlerer Stärke für Mykobakterien.
Eine vollständige Liste der häufigsten Reinigungs- und Desinfektionsmittel finden Sie im entsprechenden Dokument
zu den Reinigungs- und Desinfektionsmitteln auf der Webseite www.sonosite.com.
Tabelle 3: Zugelassene hochgradige kompatible Desinfektionsmittel
Desinfekti-
onsmittel
a
Kompatibler Schallkopf Temperatur
Eintauchzeit in
Desinfektionsmittel
Cidex rP19xp
25
o
C
45 Minuten
Cidex OPA rP19xp
20
o
C
12 Minuten
a
Eine vollständige Liste der häufigsten Reinigungs- und Desinfektionsmittel finden Sie im entsprechenden
Dokument zu den Reinigungs- und Desinfektionsmitteln auf der Webseite
www.sonosite.com.
WARNHINWEIS Um Beschädigungen des Geräts oder eine Verletzung des Patienten zu
vermeiden, die rP19xp-Nadelführungshalterung nicht bei Patienten mit
einem Schrittmacher oder medizinischen elektronischen Implantaten
einsetzen. Die rP19xp-Nadelführungshalterung enthält einen Magneten,
der die korrekte Ausrichtung der Halterung zum Schallkopf sicherstellt. In
unmittelbarer Nähe zu Herzschrittmachern oder sonstigen elektronischen
medizinischen Implantaten kann sich das Magnetfeld nachteilig auswirken.
English Deutsch Español Français Italiano Português
Schall-Ausgangsleistung 21
Nederlands
Kompatible Zubehörteile und Peripheriegeräte
Schall-Ausgangsleistung
Richtlinien zur Reduzierung des MI und TI
Tabelle 4: Zubehör und Peripheriegeräte
Beschreibung Maximale Kabellänge
Schallkopf rP19xp
a
1,8 m
a
Für Schallköpfe wird die maximale Kabellänge zwischen den Zugentlastungen gemessen. Die angegebenen Längen
enthalten nicht die Kabellängen an den folgenden Stellen: unter den Zugentlastungen, im Schallkopfgehäuse und im
Schallkopfstecker.
Tabelle 5: Richtlinien zur Reduzierung des Mechanischen Index (MI)
Schallkopf Tiefe
rP19xp
Verringerung des Parameterwerts zur Reduzierung von MI.
Erhöhung des Parameterwerts zur Reduzierung von MI.
22 Schall-Ausgangsleistung
Ausgangsleistungsanzeige
Tabelle 6: Richtlinien zur Reduzierung des Thermischen Index (TI)
Schallkopf
CPD-Einstellungen
PW-
Einstellu
ngen
Breite
des
Bereichs
Höhe des
Bereichs
Tiefe des
Bereichs
PRF Tiefe
Optimie-
ren
rP19xp
(PRF)
Verringerung des Parameterwerts zur Reduzierung von TI.
Erhöhung des Parameterwerts zur Reduzierung von TI.
Tabelle 7: TI oder MI 1,0
Schallkopf Index
2D/
M Mode
CPD/
Farbe
PW-
Doppler
CW-
Doppler
rP19xp MI Ja Ja Ja Nein
TIC, TIK oder
TIW
Ja Ja Ja Ja
Tabelle 8: Anstieg der Schallkopfoberflächentemperatur, Externe Anwendung (°C )
Test rP19xp
Ruhende Luft 15,8
Simulierte
Anwendung
8,8
English Deutsch Español Français Italiano Português
Schall-Ausgangsleistung 23
Nederlands
Schallausgangsleistungs-Tabellen
Tabelle 9: Schallkopfmodell: rP19xp Betriebsmodus: 2D
Index-Bezeichnung M.I.
TIW TIK
TIC
Scan
Non-scan
Non-scan
A
aprt
1 A
aprt
>1
Globaler maximaler Indexwert 1,5 1,2 2,9
Assoziierter Schall-
Schallparameter
p
r.3
(MPa) 1,95
W
0
(mW) 120,0 190,8
Min. von
[W
.3
(z
1
),I
TA.3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm)
z@PII
0,3max
2,6
d
eq
(z
sp
) (cm)
F
c
(MHz) 1,72 2,02 1,80
Dim. von A
aprt
X (cm) 1,92 1,92
Y (cm) 1,15 1,15
Zusätzliche Informationen
PD (μs) 1,227
PRF (Hz) 2933
p
r
@PII
max
(MPa) 2,30
d
eq
@Pll
max
(cm)
Fokuslänge FL
x
(cm) 3,42 3,42
FL
y
(cm) 9,00 9,00
I
PA.3
@MI
max
(W/cm
2
)
225
Betriebs-
Steuerelement
bedingungen
Kontrolle 1: Untersuchungstyp Krd Abd Abd
Kontrolle 2: Optimierung Allg Tief Allg
Kontrolle 3: Tiefe 7 cm 5 cm 5 cm
Kontrolle 4: THI Ein Aus Ein
Kontrolle 5: Sektorbreite Voll n. z. n. z.
Für diesen Schallkopf/Betriebsmodus nicht zutreffend.
24 Schall-Ausgangsleistung
Tabelle 10: Schallkopfmodell: rP19xp Betriebsmodus: M Mode
Index-Bezeichnung M.I.
TIW TIK
TIC
Scan
Non-scan
Non-scan
A
aprt
1 A
aprt
>1
Globaler maximaler Indexwert 1,5 1,1 0,9 3,0
Assoziierter Schall-
Schallparameter
p
r.3
(MPa) 1,95
W
0
(mW) 105 9,8 25,4 180,5
Min. von
[W
.3
(z
1
),I
TA.3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm) 3,02
z@PII
0,3max
2,6
d
eq
(z
sp
) (cm) 0,444
F
c
(MHz) 1,72 2,09 2,09 1,732 1,75
Dim. von A
aprt
X (cm) 1,92 0,78 1,02 1,92
Y (cm) 1,15 1,15 1,15 1,15
Zusätzliche Informationen
PD (μs) 1,227
PRF (Hz) 2693
p
r
@PII
max
(MPa) 2,30
d
eq
@Pll
max
(cm) 0,427
Fokuslänge FL
x
(cm) 4,56 4,56 2,25
FL
y
(cm) 9,00 9,00 9,00
I
PA.3
@MI
max
(W/cm
2
)
225
Betriebs-
Steuerelement
bedingungen
Kontrolle 1: Untersuchungstyp Krd Abd Krd Abd
Kontrolle 2: Optimierung Allg Tief Allg Allg
Kontrolle 3: Tiefe 7 cm 7 cm 13 cm 5 cm
Kontrolle 4: THI Ein Aus Ein Ein
Für diesen Schallkopf/Betriebsmodus nicht zutreffend.
English Deutsch Español Français Italiano Português
Schall-Ausgangsleistung 25
Nederlands
Tabelle 11: Schallkopfmodell: rP19xp Betriebsmodus: Farbe/CPD
Index-Bezeichnung M.I.
TIW TIK
TIC
Scan
Non-scan
Non-scan
A
aprt
1 A
aprt
>1
Globaler maximaler Indexwert 1,5 1,6 3,8
Assoziierter Schall-
Schallparameter
p
r.3
(MPa) 2,15
W
0
(mW) 134,3 174,1
Min. von
[W
.3
(z
1
),I
TA.3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm)
z@PII
0,3max
4,3
d
eq
(z
sp
) (cm)
F
c
(MHz) 2,05 2,60 2,09
Dim. von A
aprt
X (cm) 1,34 0,63
Y (cm) 1,15 1,15
Zusätzliche Informationen
PD (μs) 1,662
PRF (Hz) 1526
p
r
@PII
max
(MPa) 2,91
d
eq
@Pll
max
(cm)
Fokuslänge FL
x
(cm) 4,56 2,25
FL
y
(cm) 9,00 9,00
I
PA.3
@MI
max
(W/cm
2
)
355
Betriebs-
Steuerelement
bedingungen
Kontrolle 1: Untersuchungstyp Lunge GBH Krd
Kontrolle 2: Modus CVD CVD CVD
Kontrolle 3: 2D-Optimierung/
Tiefe
Allg/
13 cm
Allg/
5 cm
Tief/
5 cm
Kontrolle 4: Sektorbreite/THI n. z. n. z./Aus Mittel/
Ein
Steuerelement 5:
Farboptimierung/PRF
Niedrig/
273 Hz
Hoch/
2841 Hz
Hoch/
3571 Hz
Kontrolle 6: Position/Größe des
Farbbereichs
Def./
Schmal
Unten/
Klein
Def./
Schmal
Für diesen Schallkopf/Betriebsmodus nicht zutreffend.
26 Schall-Ausgangsleistung
Tabelle 12: Schallkopfmodell: rP19xp Betriebsmodus: PW-Doppler
Index-Bezeichnung M.I.
TIW TIK
TIC
Scan
Non-scan
Non-scan
A
aprt
1 A
aprt
>1
Globaler maximaler Indexwert 1,5 1,9 4,0 3,2
Assoziierter Schall-
Schallparameter
p
r.3
(MPa) 2,17
W
0
(mW) 192,5 211,8
Min. von
[W
.3
(z
1
),I
TA.3
(z
1
)]
(mW) 108,3
z
1
(cm) 1,9
Z
bp
(cm) 2,5
Z
sp
(cm) 5,10
z@PII
0,3max
0,5
d
eq
(z
sp
) (cm) 0,60
F
c
(MHz) 2,08 3,69 2,06 2,04
Dim. von A
aprt
X (cm) 1,92 1,92 1,92
Y (cm) 1,15 1,15 1,15
Zusätzliche Informationen
PD (μs) 1,141
PRF (Hz) 1562
p
r
@PII
max
(MPa) 2,24
d
eq
@Pll
max
(cm) 0,54
Fokuslänge FL
x
(cm) 11,51 11,51
FL
y
(cm) 9,00 9,00
I
PA.3
@MI
max
(W/cm
2
)
156
Betriebs-
Steuerelement
bedingungen
Kontrolle 1: Untersuchungstyp Abd Krd Abd Abd
Kontrolle 2: Länge Probengröße 1 mm 7 mm 1 mm 1 mm
Kontrolle 3: Position Probengröße Zone 0
(13 mm)
Zone7
(115 mm)
Zone 6
(96 mm)
Zone 7
(115 mm)
Kontrolle 4: PRF 1562 Hz 1008 Hz 1562 Hz 1562 Hz
Kontrolle 5: TDI Aus Ein Aus Aus
Für diesen Schallkopf/Betriebsmodus nicht zutreffend.
English Deutsch Español Français Italiano Português
Schall-Ausgangsleistung 27
Nederlands
Tabelle 13: Schallkopfmodell: rP19xp Betriebsmodus: CW-Doppler
Index-Bezeichnung M.I.
TIW TIK
TIC
Scan
Non-scan
Non-scan
A
aprt
1 A
aprt
>1
Globaler maximaler Indexwert (a) 1,2 4,0 3,1
Assoziierter Schall-
Schallparameter
p
r.3
(MPa) #
W
0
(mW) 130,6 134,7 125,7
Min. von
[W
.3
(z
1
),I
TA.3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm) 3,40
z@PII
0,3max
#
d
eq
(z
sp
) (cm) 0,47
F
c
(MHz) # 2,00 2,00 2,00
Dim. von A
aprt
X (cm) 0,90 0,90 0,72
Y (cm) 1,15 1,15 1,15
Zusätzliche Informationen
PD (μs) #
PRF (Hz) #
p
r
@PII
max
(MPa) #
d
eq
@Pll
max
(cm) 0,47
Fokuslänge FL
x
(cm) 22,01 1,30
FL
y
(cm) 9,00 9,00
I
PA.3
@MI
max
(W/cm
2
)
#
Betriebs-
Steuerelement
bedingungen
Kontrolle 1: Untersuchungstyp Krd Krd Krd
Kontrolle 2: Position Probengröße Zone 11
(220 mm)
Zone 10
(189 mm)
Zone 0
(13 mm)
(a) Dieser Index ist für diesen Betriebsmodus nicht erforderlich. Der Wert ist <1.
# Für diese Betriebsbedingung liegen keine Daten vor, da aus dem angegebenen Grund kein globaler
Maximalindexwert vorliegt. (Siehe Zeile „Globaler maximaler Indexwert“.)
Für diesen Schallkopf/Betriebsmodus nicht zutreffend.
28 Schall-Ausgangsleistung
Tabelle 14: Schallkopfmodell: rP19xp (für orbitale Untersuchungen) Betriebsmodus: 2D
Index-Bezeichnung M.I.
TIW TIK
TIC
Scan
Non-scan
Non-scan
A
aprt
1 A
aprt
>1
Globaler maximaler Indexwert 0,17 0,026 0,057
Assoziierter Schall-
Schallparameter
p
r.3
(MPa) 0,26
W
0
(mW) 2,35 3,88
Min. von
[W
.3
(z
1
),I
TA.3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm)
z@PII
0,3max
4,00
d
eq
(z
sp
) (cm)
F
c
(MHz) 2,34 2,33 2,34
Dim. von A
aprt
X (cm) 1,92 1,92
Y (cm) 1,15 1,15
Zusätzliche Informationen
PD (μs) 0,59
PRF (Hz) 2317
p
r
@PII
max
(MPa) 0,45
d
eq
@Pll
max
(cm)
Fokuslänge FL
x
(cm) 16,77 16,77
FL
y
(cm) 9,00 9,00
I
PA.3
@MI
max
(W/cm
2
)
3,41
Betriebs-
Steuerelement
bedingungen
Kontrolle 1: Untersuchungstyp Orb Orb Orb
Kontrolle 2: Optimierung Allg Allg Allg
Kontrolle 3: Tiefe 31 cm 31 cm 31 cm
Kontrolle 4: THI Aus Aus Aus
Für diesen Schallkopf/Betriebsmodus nicht zutreffend.
English Deutsch Español Français Italiano Português
Schall-Ausgangsleistung 29
Nederlands
Tabelle 15: Schallkopfmodell: rP19xp (für orbitale Untersuchungen) Betriebsmodus: M Mode
Index-Bezeichnung M.I.
TIW TIK
TIC
Scan
Non-scan
Non-scan
A
aprt
1 A
aprt
>1
Globaler maximaler Indexwert 0,17 0,025 0,012 0,055
Assoziierter Schall-
Schallparameter
p
r.3
(MPa) 0,26
W
0
(mW) 1,848 0,84 3,68
Min. von
[W
.3
(z
1
),I
TA.3
(z
1
)]
(mW) 0,41
z
1
(cm) 2,80
Z
bp
(cm) 2,52
Z
sp
(cm) 3,8
z@PII
0,3max
4,00
d
eq
(z
sp
) (cm) 0,85
F
c
(MHz) 2,34 2,37 2,37 2,34 2,37
Dim. von A
aprt
X (cm) 1,92 1,92 1,92 1,92
Y (cm) 1,15 1,15 1,15 1,15
Zusätzliche Informationen
PD (μs) 0,59
PRF (Hz) 1600
p
r
@PII
max
(MPa) 0,45
d
eq
@Pll
max
(cm) 0,58
Fokuslänge FL
x
(cm) 14,0 14,0 14,0
FL
y
(cm) 9,0 9,0 9,0
I
PA.3
@MI
max
(W/cm
2
)
3,41
Betriebs-
Steuerelement
bedingungen
Kontrolle 1: Untersuchungstyp Orb Orb Orb Orb
Kontrolle 2: Optimierung Allg Allg Allg Allg
Kontrolle 3: Tiefe 31 cm 25 cm 31 cm 25 cm
Kontrolle 4: THI Aus Aus Aus Aus
Für diesen Schallkopf/Betriebsmodus nicht zutreffend.
30 Schall-Ausgangsleistung
Tabelle 16: Schallkopfmodell: rP19xp (für orbitale Untersuchungen) Betriebsmodus: Farbe/CPD
Index-Bezeichnung M.I.
TIW TIK
TIC
Scan
Non-scan
Non-
scan
A
aprt
1 A
aprt
>1
Globaler maximaler Indexwert 0,20 0,055 0,12
Assoziierter Schall-
Schallparameter
p
r.3
(MPa) 0,28
W
0
(mW) 5,55 5,77
Min. von
[W
.3
(z
1
),I
TA.3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm)
z@PII
0,3max
0,4
d
eq
(z
sp
) (cm)
F
c
(MHz) 2,07 2,068 2,068
Dim. von A
aprt
X (cm) 0,96 0,96
Y (cm) 1,15 1,15
Zusätzliche Informationen
PD (μs) 1,55
PRF (Hz) 6301
p
r
@PII
max
(MPa) 0,29
d
eq
@Pll
max
(cm)
Fokuslänge FL
x
(cm) 1,3 1,3
FL
y
(cm) 9,0 9,0
I
PA.3
@MI
max
(W/cm
2
)
2,58
Betriebs-
Steuerelement
bedingungen
Kontrolle 1: Untersuchungstyp Orb Orb Orb
Kontrolle 2: Modus CVD CVD CVD
Kontrolle 3: 2D-Optimierung/Tiefe Allg./5 cm Allg./
5
cm
Allg./
5
cm
Kontrolle 4: Farboptimierung/PRF Mittel/
2778 Hz
Med/
2778 Hz
Med/
2778 Hz
Steuerelement 5: Position/Größe
des Farbbereichs
Standard/
Oben
Standard/
Oben
Standard/
Oben
Für diesen Schallkopf/Betriebsmodus nicht zutreffend.
English Deutsch Español Français Italiano Português
Schall-Ausgangsleistung 31
Nederlands
Tabelle 17: Schallkopfmodell: rP19xp (für orbitale Untersuchungen) Betriebsmodus: PW-Doppler
Index-Bezeichnung M.I.
TIW TIK
TIC
Scan
Non-scan
Non-scan
A
aprt
1 A
aprt
>1
Globaler maximaler Indexwert 0,19 0,22 0,56 0,51
Assoziierter Schall-
Schallparameter
p
r.3
(MPa) 0,28
W
0
(mW) 33,8 34,4
Min. von
[W
.3
(z
1
),I
TA.3
(z
1
)]
(mW) 21,89
z
1
(cm) 3,00
Z
bp
(cm) 2,52
Z
sp
(cm) 3,8
z@PII
0,3max
0,8
d
eq
(z
sp
) (cm) 0,79
F
c
(MHz) 2,11 2,09 2,09 2,09
Dim. von A
aprt
X (cm) 1,92 1,92 1,92
Y (cm) 1,15 1,15 1,15
Zusätzliche Informationen
PD (μs) 3,67
PRF (Hz) 3906
p
r
@PII
max
(MPa) 0,29
d
eq
@Pll
max
(cm) 0,69
Fokuslänge FL
x
(cm) 22,0 27,3
FL
y
(cm) 9,0 9,0
I
PA.3
@MI
max
(W/cm
2
)
2,43
Betriebs-
Steuerelement
bedingungen
Kontrolle 1: Untersuchungstyp Orb Orb Orb Orb
Kontrolle 2: Länge Probengröße 3 mm 9 mm 9 mm 7 mm
Kontrolle 3: Position Probengröße Zone 1
(23 mm)
Zone 11
(220 mm)
Zone 11
(220 mm)
Zone 13
(273 mm)
Kontrolle 4: PRF 3906 Hz 2604 Hz 2604 Hz 1953 Hz
Für diesen Schallkopf/Betriebsmodus nicht zutreffend.
32 Schall-Ausgangsleistung
English Deutsch Español Fraais Italiano Português
Introducción 33
Nederlands
Suplemento del Manual de usuario del
transductor SonoSite X-Porte rP19xp
Introducción ................................................................................................................................................. 33
Convenciones utilizadas en el documento ................................................................................................................................ 33
Obtención de ayuda .............................................................................................................................................................................. 34
Modos de imagen ........................................................................................................................................ 35
Limpieza y desinfección ............................................................................................................................. 36
Seguridad ..................................................................................................................................................... 36
Accesorios y periféricos compatibles ........................................................................................................................................... 37
Emisión acústica .......................................................................................................................................... 37
Pautas para reducir el índice mecánico y el índice térmico .............................................................................................. 37
Lectura de salida ...................................................................................................................................................................................... 38
Tablas de emisión acústica ................................................................................................................................................................. 39
Introducción
Este suplemento al manual para el usuario proporciona información sobre el transductor rP19xp, compatible
con el sistema de ecografía SonoSite X-Porte.
Convenciones utilizadas en el documento
Este documento sigue las siguientes convenciones:
Los mensajes de ADVERTENCIA describen las precauciones necesarias para evitar lesiones o situaciones
que entrañen peligro de muerte.
Los mensajes de Precaución describen las precauciones necesarias para proteger los productos.
Una Nota proporciona información adicional.
Los pasos que aparecen con números y letras deben ejecutarse en un orden determinado.
Las listas con viñetas presentan información en forma de lista, sin que ello implique una secuencia.
Para obtener una descripción de los símbolos del etiquetado que aparecen en el producto, consulte
«Símbolos del etiquetado» en el manual para el usuario del sistema de ecografía.
34 Introducción
Obtención de ayuda
Para obtener asistencia técnica, póngase en contacto con FUJIFILM SonoSite por los siguientes medios:
Impreso en Estados Unidos.
Por teléfono
(EE. UU. o Canadá)
+1-877-657-8118
Por teléfono
(fuera de EE. UU. o
Canadá)
+1-425-951-1330, o bien llame a su representante local
Fax +1-425-951-6700
Correo electrónico [email protected]
Web www.sonosite.com
Centro de servicio al
cliente en Europa
Principal: +31 20 751 2020
Asistencia técnica en inglés: +44 14 6234 1151
Asistencia técnica en francés: +33 1 8288 0702
Asistencia técnica en alemán: +49 69 8088 4030
Asistencia técnica en italiano: +39 02 9475 3655
Asistencia técnica en español: +34 91 123 8451
Centro de servicio al
cliente en Asia
+65 6380-5581
English Deutsch Español Fraais Italiano Português
Modos de imagen 35
Nederlands
Modos de imagen
Tabla 1: Tipos de examen y modos de imagen disponibles
Transductor
Tipo de
examen
Modo de imagen
2D
Modo M
Color
a
Doppler
PW
b
Doppler
CW
rP19xp Abdominal CVD, CPD
Cardíaco CVD, Var
Pulmonar CVD, CPD
Obstétrico CVD, CPD
Orbital CVD, CPD
Transcraneal CVD, CPD
a
Var = varianza de Doppler en color, solo disponible en el examen cardíaco. CPD = Doppler de potencia
en color, disponible en todos los exámenes excepto en el tipo cardíaco. CVD = Doppler de velocidad en
color.
b
Para exámenes cardíacos también está disponible PW TDI.
Nota El transductor rP19xp es compatible con guías de aguja. Para obtener más
información consulte Using CIVCO Products with FUJIFILM SonoSite Systems
(Uso de productos CIVCO con sistemas FUJIFILM SonoSite).
36 Limpieza y desinfección
Limpieza y desinfección
Seguridad
Tabla 2: Productos de limpieza aprobados
Producto Transductor compatible
Tiempo mínimo de contacto en
mojado
a
SaniCloth AF3
b
rP19xp 3 minutos
PI-Spray II rP19xp 10 minutos
a
Para obtener la mayor eficacia, el componente que se está limpiando debe permanecer húmedo con desinfectante
durante un periodo mínimo de tiempo.
b
Apto para uso como desinfección de nivel intermedio para micobacterias.
Consulte el documento de limpiadores y desinfección que hay disponible en www.sonosite.com para ver una
lista completa de los productos de limpieza y desinfección más actualizados.
Tabla 3: Desinfectantes de alto nivel compatibles aprobados
Desinfectante
a
Transductor compatible Temperatura
Duración del remojo en
desinfectante
Cidex rP19xp
25
o
C
45 minutos
Cidex OPA rP19xp
20
o
C
12 minutos
a
Consulte el documento de limpiadores y desinfección que hay disponible en www.sonosite.com para ver una
lista completa de los productos de limpieza y desinfección más actualizados.
ADVERTENCIA Para evitar dañar el dispositivo y causar lesiones al paciente, no utilice el
soporte para guía de aguja rP19xp en pacientes con marcapasos o
implantes electromédicos. Dicho soporte para el rP19xp contiene un imán
que se utiliza para asegurar que el soporte se encuentre orientado
correctamente en el transductor. El campo magnético en proximidad directa
al marcapasos o al implante electromédico puede tener un efecto adverso.
English Deutsch Español Fraais Italiano Português
Emisión acústica 37
Nederlands
Accesorios y periféricos compatibles
Emisión acústica
Pautas para reducir el índice mecánico y el índice térmico
Tabla 4: Accesorios y periféricos
Descripción Longitud máxima del cable
Transductor rP19xp
a
1,8 m
a
Para los transductores, la longitud máxima del cable se mide entre cada protección contra tirones. Las longitudes
mencionadas no incluyen las longitudes de cable en los siguientes puntos: debajo de las protecciones contra tirones,
dentro de la caja del transductor o dentro del conector del transductor.
Tabla 5: Pautas para reducir el índice mecánico (IM)
Transductor Profundidad
rP19xp
Disminuir o bajar el ajuste del parámetro para reducir el IM.
Aumentar o subir el ajuste del parámetro para reducir el IM.
38 Emisión acústica
Lectura de salida
Tabla 6: Pautas para reducir el índice térmico (IT)
Transductor
Ajustes del modo CPD
Ajustes
del modo
PW
Anchura
del
cuadro
Altura
del
cuadro
Profundi-
dad del
cuadro
PRF
Profundi-
dad
Optimizar
rP19xp
(PRF)
Disminuir o bajar el ajuste del parámetro para reducir el IT.
Aumentar o subir el ajuste del parámetro para reducir el IT.
Tabla 7: IT o IM 1,0
Transductor Índice
2D/
Modo M
CPD/
Color
Doppler
PW
Doppler
CW
rP19xp IM No
TIC, TIB o TIS
Tabla 8: Aumento de temperatura en la superficie de los transductores, uso externo (°C )
Prueba rP19xp
Aire en reposo 15,8
Uso simulado 8,8
English Deutsch Español Fraais Italiano Português
Emisión acústica 39
Nederlands
Tablas de emisión acústica
Tabla 9: Modelo de transductor: rP19xp. Modo de funcionamiento: 2D
Etiqueta de índice I.M.
TIS TIB
TIC
Explo-
ración
Sin exploración
Sin explo-
ración
A
aprt
1 A
aprt
> 1
Valor de índice máximo global 1,5 1,2 2,9
Parámetro acústico
asociado
p
r0,3
(MPa) 1,95
W
0
(mW) 120,0 190,8
mín de
[W
0,3
(z
1
),I
TA0,3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm)
z@PII
0,3máx
2,6
d
eq
(z
sp
) (cm)
F
c
(MHz) 1,72 2,02 1,80
Dim. de A
aprt
X (cm) 1,92 1,92
Y (cm) 1,15 1,15
Otra información
PD (μs) 1,227
PRF (Hz) 2933
p
r
@PII
máx
(MPa) 2,30
d
eq
@Pll
máx
(cm)
Distancia focal FL
x
(cm) 3,42 3,42
FL
y
(cm) 9,00 9,00
I
PA0,3
@IM
máx
(W/cm
2
)
225
Condiciones
de control
de funcionamiento
Control 1: Tipo de examen Crd Abd Abd
Control 2: Optimización Gen Pen Gen
Control 3: Profundidad 7 cm 5 cm 5 cm
Control 4: THI Activado Desac-
tivado
Acti-
vado
Control 5: Anchura del sector Completo N/D N/D
Los datos no son aplicables a este transductor/modo.
40 Emisión acústica
Tabla 10: Modelo de transductor: rP19xp. Modo de funcionamiento: Modo M
Etiqueta de índice I.M.
TIS TIB
TIC
Explo-
ración
Sin exploración
Sin explo-
ración
A
aprt
1 A
aprt
> 1
Valor de índice máximo global 1,5 1,1 0,9 3,0
Parámetro acústico
asociado
p
r0,3
(MPa) 1,95
W
0
(mW) 105 9,8 25,4 180,5
mín de
[W
0,3
(z
1
),I
TA0,3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm) 3,02
z@PII
0,3máx
2,6
d
eq
(z
sp
) (cm) 0,444
F
c
(MHz) 1,72 2,09 2,09 1,732 1,75
Dim. de A
aprt
X (cm) 1,92 0,78 1,02 1,92
Y (cm) 1,15 1,15 1,15 1,15
Otra información
PD (μs) 1,227
PRF (Hz) 2693
p
r
@PII
máx
(MPa) 2,30
d
eq
@Pll
máx
(cm) 0,427
Distancia focal FL
x
(cm) 4,56 4,56 2,25
FL
y
(cm) 9,00 9,00 9,00
I
PA0,3
@IM
máx
(W/cm
2
)
225
Condiciones
de control
de funcionamiento
Control 1: Tipo de examen Crd Abd Crd Abd
Control 2: Optimización Gen Pen Gen Gen
Control 3: Profundidad 7 cm 7 cm 13 cm 5 cm
Control 4: THI Activado Desacti-
vado
Activado Acti-
vado
Los datos no son aplicables a este transductor/modo.
English Deutsch Español Fraais Italiano Português
Emisión acústica 41
Nederlands
Tabla 11: Modelo de transductor: rP19xp. Modo de funcionamiento: Color/CPD
Etiqueta de índice I.M.
TIS TIB
TIC
Explo-
ración
Sin exploración
Sin explo-
ración
A
aprt
1 A
aprt
> 1
Valor de índice máximo global 1,5 1,6 3,8
Parámetro acústico
asociado
p
r0,3
(MPa) 2,15
W
0
(mW) 134,3 174,1
mín de
[W
0,3
(z
1
),I
TA0,3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm)
z@PII
0,3máx
4,3
d
eq
(z
sp
) (cm)
F
c
(MHz) 2,05 2,60 2,09
Dim. de A
aprt
X
(cm)
1,34 0,63
Y (cm) 1,15 1,15
Otra información
PD (μs) 1,662
PRF (Hz) 1526
p
r
@PII
máx
(MPa) 2,91
d
eq
@Pll
máx
(cm)
Distancia focal FL
x
(cm) 4,56 2,25
FL
y
(cm) 9,00 9,00
I
PA0,3
@IM
máx
(W/cm
2
)
355
Los datos no son aplicables a este transductor/modo.
42 Emisión acústica
Condiciones
de control
de funcionamiento
Control 1: Tipo de examen Pulmonar Obst Crd
Control 2: Modo CVD CVD CVD
Control 3: Optimización 2D/
Profundidad
Gen/
13 cm
Gen/
5 cm
Pen/
5 cm
Control 4: Anchura del sector/THI N/D N/D/
Desacti
-
vado
Media/
Acti
-
vado
Control 5: Optimización del color/
PRF
Bajo/
273 Hz
Alta/
2841 Hz
Alta/
3571 Hz
Control 6: Posición/tamaño del
cuadro Color
Def/
Estrecho
Inferior/
Pequeño
Def/
Estre
-
cho
Tabla 11: Modelo de transductor: rP19xp. Modo de funcionamiento: Color/CPD
Etiqueta de índice I.M.
TIS TIB
TIC
Explo-
ración
Sin exploración
Sin explo-
ración
A
aprt
1 A
aprt
> 1
Los datos no son aplicables a este transductor/modo.
English Deutsch Español Fraais Italiano Português
Emisión acústica 43
Nederlands
Tabla 12: Modelo de transductor: rP19xp. Modo de funcionamiento: Doppler PW
Etiqueta de índice I.M.
TIS TIB
TIC
Explo-
ración
Sin exploración Sin
explora
-
ción
A
aprt
1 A
aprt
> 1
Valor de índice máximo global 1,5 1,9 4,0 3,2
Parámetro acústico
asociado
p
r0,3
(MPa) 2,17
W
0
(mW) 192,5 211,8
mín de
[W
0,3
(z
1
),I
TA0, 3
(z
1
)]
(mW) 108,3
z
1
(cm) 1,9
Z
bp
(cm) 2,5
Z
sp
(cm) 5,10
z@PII
0,3máx
0,5
d
eq
(z
sp
) (cm) 0,60
F
c
(MHz) 2,08 3,69 2,06 2,04
Dim. de A
aprt
X (cm) 1,92 1,92 1,92
Y (cm) 1,15 1,15 1,15
Otra información
PD (μs) 1,141
PRF (Hz) 1562
p
r
@PII
máx
(MPa) 2,24
d
eq
@Pll
máx
(cm) 0,54
Distancia focal FL
x
(cm) 11,51 11,51
FL
y
(cm) 9,00 9,00
I
PA0, 3
@IM
máx
(W/cm
2
)
156
Condiciones
de control
de funcionamiento
Control 1: Tipo de examen Abd Crd Abd Abd
Control 2: Tamaño del volumen de
la muestra
1 mm 7 mm 1 mm 1 mm
Control 3: Posición de volumen de
muestra
Zona 0
(13 mm)
Zona 7
(115 mm)
Zona 6
(96 mm)
Zona 7
(115 mm)
Control 4: PRF 1562 Hz 1008 Hz 1562 Hz 1562 Hz
Control 5: TDI Desacti-
vado
Activado Desacti-
vado
Desacti-
vado
Los datos no son aplicables a este transductor/modo.
44 Emisión acústica
Tabla 13: Modelo de transductor: rP19xp. Modo de funcionamiento: Doppler CW
Etiqueta de índice I.M.
TIS TIB
TIC
Explo-
ración
Sin exploración
Sin explo-
ración
A
aprt
1
A
aprt
>
1
Valor de índice máximo global (a) 1,2 4,0 3,1
Parámetro acústico
asociado
p
r0,3
(MPa) #
W
0
(mW) 130,6 134,7 125,7
mín de
[W
0,3
(z
1
),I
TA0,3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm) 3,40
z@PII
0,3máx
#
d
eq
(z
sp
) (cm) 0,47
F
c
(MHz) # 2,00 2,00 2,00
Dim. de A
aprt
X (cm) 0,90 0,90 0,72
Y (cm) 1,15 1,15 1,15
Otra información
PD (μs) #
PRF (Hz) #
p
r
@PII
máx
(MPa) #
d
eq
@Pll
máx
(cm) 0,47
Distancia focal FL
x
(cm) 22,01 1,30
FL
y
(cm) 9,00 9,00
I
PA0,3
@IM
máx
(W/cm
2
)
#
Condiciones
de control
de funcionamiento
Control 1: Tipo de examen Crd Crd Crd
Control 2: Posición de volumen de
muestra
Zona 11
(220 mm)
Zona 10
(189 mm)
Zona 0
(13 mm)
(a) Este índice no es necesario para este modo operativo, el valor es <1.
# No se han descrito datos para estas condiciones de funcionamiento, dado que no se ha indicado el valor global de
índice máximo por el motivo mostrado. (Línea del valor global de índice máximo de referencia.)
Los datos no son aplicables a este transductor/modo.
English Deutsch Español Fraais Italiano Português
Emisión acústica 45
Nederlands
Tabla 14: Modelo de transductor: rP19xp (Uso orbital). Modo de funcionamiento: 2D
Etiqueta de índice I.M.
TIS TIB
TIC
Explo-
ración
Sin exploración
Sin explo-
ración
A
aprt
1 A
aprt
> 1
Valor de índice máximo global 0,17 0,026 0,057
Parámetro acústico
asociado
p
r0,3
(MPa) 0,26
W
0
(mW) 2,35 3,88
mín de
[W
0,3
(z
1
),I
TA0,3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm)
z@PII
0,3máx
4,00
d
eq
(z
sp
) (cm)
F
c
(MHz) 2,34 2,33 2,34
Dim. de A
aprt
X (cm) 1,92 1,92
Y (cm) 1,15 1,15
Otra información
PD (μs) 0,59
PRF (Hz) 2317
p
r
@PII
máx
(MPa) 0,45
d
eq
@Pll
máx
(cm)
Distancia focal FL
x
(cm) 16,77 16,77
FL
y
(cm) 9,00 9,00
I
PA0,3
@IM
máx
(W/cm
2
)
3,41
Condiciones
de control
de funcionamiento
Control 1: Tipo de examen Orb Orb Orb
Control 2: Optimización Gen Gen Gen
Control 3: Profundidad 31 cm 31 cm 31 cm
Control 4: THI Desacti-
vado
Desac-
tivado
Desac-
tivado
Los datos no son aplicables a este transductor/modo.
46 Emisión acústica
Tabla 15: Modelo de transductor: rP19xp (Uso orbital). Modo de funcionamiento: Modo M
Etiqueta de índice I.M.
TIS TIB
TIC
Explo-
ración
Sin exploración
Sin explo-
ración
A
aprt
1 A
aprt
> 1
Valor de índice máximo global 0,17 0,025 0,012 0,055
Parámetro acústico
asociado
p
r0,3
(MPa) 0,26
W
0
(mW) 1,848 0,84 3,68
mín de
[W
0,3
(z
1
),I
TA0,3
(z
1
)]
(mW) 0,41
z
1
(cm) 2,80
Z
bp
(cm) 2,52
Z
sp
(cm) 3,8
z@PII
0,3máx
4,00
d
eq
(z
sp
) (cm) 0,85
F
c
(MHz) 2,34 2,37 2,37 2,34 2,37
Dim. de A
aprt
X (cm) 1,92 1,92 1,92 1,92
Y (cm) 1,15 1,15 1,15 1,15
Otra información
PD (μs) 0,59
PRF (Hz) 1600
p
r
@PII
máx
(MPa) 0,45
d
eq
@Pll
máx
(cm) 0,58
Distancia focal FL
x
(cm) 14,0 14,0 14,0
FL
y
(cm) 9,0 9,0 9,0
I
PA0,3
@IM
máx
(W/cm
2
)
3,41
Condiciones
de control
de funcionamiento
Control 1: Tipo de examen Orb Orb Orb Orb
Control 2: Optimización Gen Gen Gen Gen
Control 3: Profundidad 31 cm 25 cm 31 cm 25 cm
Control 4: THI Desacti-
vado
Desactivado Desacti-
vado
Desac-
tivado
Los datos no son aplicables a este transductor/modo.
English Deutsch Español Fraais Italiano Português
Emisión acústica 47
Nederlands
Tabla 16: Modelo de transductor: rP19xp (Uso orbital). Modo de funcionamiento: Color/CPD
Etiqueta de índice I.M.
TIS TIB
TIC
Explo-
ración
Sin exploración
Sin
explora
-
ción
A
aprt
1
A
aprt
>
1
Valor de índice máximo global 0,20 0,055 0,12
Parámetro acústico
asociado
p
r0,3
(MPa) 0,28
W
0
(mW) 5,55 5,77
mín de
[W
0,3
(z
1
),I
TA0,3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm)
z@PII
0,3máx
0,4
d
eq
(z
sp
) (cm)
F
c
(MHz) 2,07 2,068 2,068
Dim. de A
aprt
X (cm) 0,96 0,96
Y (cm) 1,15 1,15
Otra información
PD (μs) 1,55
PRF (Hz) 6301
p
r
@PII
máx
(MPa) 0,29
d
eq
@Pll
máx
(cm)
Distancia focal FL
x
(cm) 1,3 1,3
FL
y
(cm) 9,0 9,0
I
PA0,3
@IM
máx
(W/cm
2
)
2,58
Condiciones
de control
de funcionamiento
Control 1: Tipo de examen Orb Orb Orb
Control 2: Modo CVD CVD CVD
Control 3: Optimización 2D/
Profundidad
Gen/5 cm Gen/
5
cm
Gen/
5
cm
Control 4: Optimización del color/
PRF
Media/
2778 Hz
Med/
2778 Hz
Med/
2778 Hz
Control 5: Posición/tamaño del
cuadro Color
Predetermi-
nado/Supe-
rior
Prede-
termi-
nado/
Superior
Prede-
termi-
nado/
Superior
Los datos no son aplicables a este transductor/modo.
48 Emisión acústica
Tabla 17: Modelo de transductor: rP19xp (Uso orbital). Modo de funcionamiento: Doppler PW
Etiqueta de índice I.M.
TIS TIB
TIC
Explo-
ración
Sin exploración
Sin explo-
ración
A
aprt
1 A
aprt
> 1
Valor de índice máximo global 0,19 0,22 0,56 0,51
Parámetro acústico
asociado
p
r0,3
(MPa) 0,28
W
0
(mW) 33,8 34,4
mín de
[W
0,3
(z
1
),I
TA0,3
(z
1
)]
(mW) 21,89
z
1
(cm) 3,00
Z
bp
(cm) 2,52
Z
sp
(cm) 3,8
z@PII
0,3máx
0,8
d
eq
(z
sp
) (cm) 0,79
F
c
(MHz) 2,11 2,09 2,09 2,09
Dim. de A
aprt
X (cm) 1,92 1,92 1,92
Y (cm) 1,15 1,15 1,15
Otra información
PD (μs) 3,67
PRF (Hz) 3906
p
r
@PII
máx
(MPa) 0,29
d
eq
@Pll
máx
(cm) 0,69
Distancia focal FL
x
(cm) 22,0 27,3
FL
y
(cm) 9,0 9,0
I
PA0,3
@IM
máx
(W/cm
2
)
2,43
Condiciones
de control
de funcionamiento
Control 1: Tipo de examen Orb Orb Orb Orb
Control 2: Tamaño del volumen de
la muestra
3 mm 9 mm 9 mm 7 mm
Control 3: Posición de volumen de
muestra
Zona 1
(23 mm)
Zona 11
(220 mm)
Zona 11
(220 mm)
Zona 13
(273 mm)
Control 4: PRF 3906 Hz 2604 Hz 2604 Hz 1953 Hz
Los datos no son aplicables a este transductor/modo.
English Deutsch Español Fraais Italiano Português
Introduction 49
Nederlands
Supplément au guide d’utilisation de la sonde
SonoSite X-Porte rP19xp
Introduction .................................................................................................................................................. 49
Conventions du document ................................................................................................................................................................. 49
Obtenir de l’aide ...................................................................................................................................................................................... 50
Modes d’imagerie ....................................................................................................................................... 51
Nettoyage et désinfection ......................................................................................................................... 52
Sécurité ........................................................................................................................................................ 52
Accessoires et périphériques compatibles ................................................................................................................................ 53
Puissance acoustique ................................................................................................................................. 53
Consignes de réduction de l’IM et l’IT ......................................................................................................................................... 53
Affichage de la puissance acoustique .......................................................................................................................................... 54
Tableaux de puissance acoustique ................................................................................................................................................ 55
Introduction
Ce supplément au guide d’utilisation contient des informations sur la sonde rP19xp, compatible avec
l’échographe SonoSite X-Porte.
Conventions du document
Ce document utilise les conventions suivantes :
Une mention AVERTISSEMENT décrit les précautions à prendre pour éviter tout risque de blessure ou
de décès.
Une mention Mise en garde décrit les précautions à prendre pour protéger les produits.
Une mention Remarque fournit des informations complémentaires.
Les étapes associées à des numéros et à des lettres doivent être exécutées dans un ordre spécifique.
Les listes à puces présentent des informations sous forme de liste, mais n’impliquent aucun ordre
d’exécution particulier.
Pour obtenir une description des symboles d’étiquetage figurant sur le produit, voir « Symboles
d’étiquetage
» dans le guide d’utilisation de l’échographe.
50 Introduction
Obtenir de l’aide
Pour toute assistance technique, contactez FUJIFILM SonoSite :
Imprimé aux États-Unis.
Téléphone
(États-Unis ou Canada)
+1-877-657-8118
Téléphone
(hors États-Unis et
Canada)
+1-425-951-1330 ou contactez un représentant local
Fax +1-425-951-6700
E-mail ffss-service@fujifilm.com
Site web www.sonosite.com
Centre de services en
Europe
Ligne principale : +31 20 751 2020
Assistance en anglais : +44 14 6234 1151
Assistance en français : +33 1 8288 0702
Assistance en allemand : +49 69 8088 4030
Assistance en italien : +39 02 9475 3655
Assistance en espagnol : +34 91 123 8451
Centre de services en
Asie
+656380-5581
English Deutsch Español Fraais Italiano Português
Modes d’imagerie 51
Nederlands
Modes d’imagerie
Tableau 1 : Types d’examen et modes d’imagerie disponibles
Sonde
Type
d’examen
Mode d’imagerie
M Mode
2D
Couleur
a
Doppler
pulsé
(PW)
b
Doppler
continu
(CW)
rP19xp Abdomen CVD, CPD
Cardiaque CVD, Var
Poumon CVD, CPD
Obstétrique CVD, CPD
Orbital CVD, CPD
Transcrânien CVD, CPD
a
Var = Variance de Doppler couleur qui est disponible uniquement dans l’examen cardiaque. CPD =
Doppler puissance couleur qui est disponible dans tous les examens à l’exception de l’examen
cardiaque. CVD = Doppler vitesse couleur.
b
Pour le type d’examen cardiaque, l’option TDI PW est également disponible.
Remarque La sonde rP19xp accepte un guide-aiguille. Pour plus d’informations, voir Using
CIVCO Products with FUJIFILM SonoSite Systems (Utilisation des produits CIVCO
avec les échographes FUJIFILM SonoSite).
52 Nettoyage et désinfection
Nettoyage et désinfection
Sécurité
Tableau 2 : Produits de nettoyage approuvés
Produit Sonde compatible
Temps de contact humide
minimal
a
SaniCloth AF3
b
rP19xp 3 minutes
PI-Spray II rP19xp 10 minutes
a
Pour une efficacité maximale, le composant nettoyé doit rester imprégné de désinfectant pendant une durée
minimale.
b
Homologué pour être utilisé comme désinfectant de niveau intermédiaire pour les mycobactéries.
Voir le document relatif aux détergents et aux désinfectants disponible sur www.sonosite.com pour obtenir la liste
complète des détergents et désinfectants les plus récents.
Tableau 3 : Désinfectants compatibles de haut niveau approuvés
Désinfectant
a
Sonde compatible Température
Durée de trempage dans le
désinfectant
Cidex rP19xp
25
o
C
45 minutes
Cidex OPA rP19xp
20
o
C
12 minutes
a
Voir le document relatif aux détergents et aux désinfectants disponible sur www.sonosite.com pour obtenir la liste
complète des détergents et désinfectants les plus récents.
AVERTISSEMENT Pour ne pas endommager l’appareil ou blesser le patient, n’utilisez pas le
bracelet de guidage d’aiguille rP19xp sur les patients porteurs d’un
stimulateur cardiaque ou d’un implant électronique médical. Le bracelet
de guidage d’aiguille pour rP19xp contient un aimant qui permet
d’orienter le bracelet correctement sur la sonde. Son champ magnétique,
en proximité directe avec un stimulateur cardiaque ou un implant
électronique médical, peut avoir un effet négatif.
English Deutsch Español Fraais Italiano Português
Puissance acoustique 53
Nederlands
Accessoires et périphériques compatibles
Puissance acoustique
Consignes de réduction de l’IM et l’IT
Tableau 4 : Accessoires et périphériques
Description Longueur maximale du câble
sonde rP19xp
a
1,8 m
a
Pour les sondes, la longueur maximale du câble est mesurée entre les serre-câbles. Les longueurs indiquées n’in-
cluent pas les longueurs de câble situées sous les serre-câbles, à l’intérieur du boîtier du transducteur et du connec-
teur du transducteur.
Tableau 5 : Recommandations pour réduire l’indice mécanique (IM)
Sonde Profondeur
rP19xp
Baisser le réglage du paramètre afin de réduire l’IM.
Augmenter le réglage du paramètre afin de réduire l’IM.
54 Puissance acoustique
Affichage de la puissance acoustique
Tableau 6 : Recommandations pour réduire l’indice thermique (IT)
Sonde
Réglages CPD
Réglages
PW
Largeur
de la
zone
Hauteur
de la
zone
Profon-
deur de
la zone
FRI
Profon-
deur
Optimi-
ser
rP19xp
(FRI)
Baissez le réglage du paramètre afin de réduire l’IT.
Augmentez le réglage du paramètre afin de réduire l’IT.
Tableau 7 : IT ou IM 1,0
Sonde Index
2D/
M Mode
CPD/
Couleur
Doppler
pulsé (PW)
Doppler
continu
(CW)
rP19xp IM Oui Oui Oui Non
ITC, ITO ou ITM Oui Oui Oui Oui
Tableau 8 : Augmentation de la température de surface des sondes, usage externe (°C )
Test rP19xp
Air immobile 15,8
Simulation
d’utilisation
8,8
English Deutsch Español Fraais Italiano Português
Puissance acoustique 55
Nederlands
Tableaux de puissance acoustique
Tableau 9 : Modèle de sonde : rP19xp Mode de fonctionnement : 2D
Libellé de l’indice IM
ITM ITO
ITC
Balayage
Fixe
Fixe
A
ouac
1 A
ouac
>1
Valeur de l’indice maximal global 1,5 1,2 2,9
Paramètre acoustique
associé
p
r.3
(MPa) 1,95
W
0
(mW) 120,0 190,8
min de
[W
.3
(z
1
),I
TA.3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm)
z@PII
.3max
2,6
d
eq
(z
sp
) (cm)
F
c
(MHz) 1,72 2,02 1,80
Dim de A
ouac
X (cm) 1,92 1,92
Y (cm) 1,15 1,15
Autres informations
PD (μs) 1,227
FRI (Hz) 2933
p
r
@PII
max
(MPa) 2,30
d
eq
@Pll
max
(cm)
Longueur focale LF
x
(cm) 3,42 3,42
LF
y
(cm) 9,00 9,00
I
MI.3
@IM
max
(W/cm
2
)
225
Conditions
Commande
de fonctionnement
Commande 1 : Type d’examen Crd Abd Abd
Commande 2 : Optimisation Gén n Gén
Commande 3 : Profondeur 7 cm 5 cm 5 cm
Commande 4 : THI Actif Inactif Actif
Commande 5 : Largeur du secteur Entier S/O S/O
Données non applicables pour ce transducteur/ce mode.
56 Puissance acoustique
Tableau 10 : Modèle de sonde : rP19xp Mode de fonctionnement : M Mode
Libellé de l’indice IM
ITM ITO
ITC
Balayage
Fixe
Fixe
A
ouac
1 A
ouac
>1
Valeur de l’indice maximal global 1,5 1,1 0,9 3,0
Paramètre acoustique
associé
p
r.3
(MPa) 1,95
W
0
(mW) 105 9,8 25,4 180,5
min de
[W
.3
(z
1
),I
TA.3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm) 3,02
z@PII
.3max
2,6
d
eq
(z
sp
) (cm) 0,444
F
c
(MHz) 1,72 2,09 2,09 1,732 1,75
Dim de A
ouac
X (cm) 1,92 0,78 1,02 1,92
Y (cm) 1,15 1,15 1,15 1,15
Autres informations
PD (μs) 1,227
FRI (Hz) 2693
p
r
@PII
max
(MPa) 2,30
d
eq
@Pll
max
(cm) 0,427
Longueur focale LF
x
(cm) 4,56 4,56 2,25
LF
y
(cm) 9,00 9,00 9,00
I
MI.3
@IM
max
(W/cm
2
)
225
Conditions
Commande
de fonctionnement
Commande 1 : Type d’examen Crd Abd Crd Abd
Commande 2 : Optimisation Gén n Gén Gén
Commande 3 : Profondeur 7 cm 7 cm 13 cm 5 cm
Commande 4 : THI Actif Inactif Actif Actif
Données non applicables pour ce transducteur/ce mode.
English Deutsch Español Fraais Italiano Português
Puissance acoustique 57
Nederlands
Tableau 11 : Modèle de sonde : rP19xp Mode de fonctionnement : Couleur/CPD
Libellé de l’indice IM
ITM ITO
ITC
Balayage
Fixe
Fixe
A
ouac
1 A
ouac
>1
Valeur de l’indice maximal global 1,5 1,6 3,8
Paramètre acoustique
associé
p
r.3
(MPa) 2,15
W
0
(mW) 134,3 174,1
min de
[W
.3
(z
1
),I
TA.3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm)
z@PII
.3max
4,3
d
eq
(z
sp
) (cm)
F
c
(MHz) 2,05 2,60 2,09
Dim de A
ouac
X (cm) 1,34 0,63
Y (cm) 1,15 1,15
Autres informations
PD (μs) 1,662
FRI (Hz) 1526
p
r
@PII
max
(MPa) 2,91
d
eq
@Pll
max
(cm)
Longueur focale LF
x
(cm) 4,56 2,25
LF
y
(cm) 9,00 9,00
I
MI.3
@IM
max
(W/cm
2
)
355
Conditions
Commande
de fonctionnement
Commande 1 : Type d’examen Poumon OB Crd
Commande 2 : Mode CVD CVD CVD
Commande 3 : Optimisation/
Profondeur 2D
Gén/
13 cm
Gén/
5 cm
n/
5 cm
Commande 4 : Largeur du
secteur/IHT
S/O S/O/
Inactif
Moyen/
Actif
Commande 5 : Optimisation des
couleurs/FRI
Bas/
273 Hz
Haut/
2841 Hz
Haut/
3571 Hz
Commande 6 : Position/Taille de
la zone Couleur
Déf/Étroite Inférieure
/Petite
Déf/
Étroite
Données non applicables pour ce transducteur/ce mode.
58 Puissance acoustique
Tableau 12 : Modèle de sonde : rP19xp Mode de fonctionnement : Doppler pulsé (PW)
Libellé de l’indice IM
ITM ITO
ITC
Balayage
Fixe
Fixe
A
ouac
1 A
ouac
>1
Valeur de l’indice maximal global 1,5 1,9 4,0 3,2
Paramètre acoustique
associé
p
r.3
(MPa) 2,17
W
0
(mW) 192,5 211,8
min de
[W
.3
(z
1
),I
TA.3
(z
1
)]
(mW) 108,3
z
1
(cm) 1,9
Z
bp
(cm) 2,5
Z
sp
(cm) 5,10
z@PII
.3max
0,5
d
eq
(z
sp
) (cm) 0,60
F
c
(MHz) 2,08 3,69 2,06 2,04
Dim de A
ouac
X (cm) 1,92 1,92 1,92
Y (cm) 1,15 1,15 1,15
Autres informations
PD (μs) 1,141
FRI (Hz) 1562
p
r
@PII
max
(MPa) 2,24
d
eq
@Pll
max
(cm) 0,54
Longueur focale LF
x
(cm) 11,51 11,51
LF
y
(cm) 9,00 9,00
I
MI.3
@IM
max
(W/cm
2
)
156
Conditions
Commande
de fonctionnement
Commande 1 : Type d’examen Abd Crd Abd Abd
Commande 2 : Taille du volume
d’échantillon
1 mm 7 mm 1 mm 1 mm
Commande 3 : Position du
volume d’échantillon
Zone 0
(13 mm)
Zone 7
(115 mm)
Zone 6
(96 mm)
Zone 7
(115 mm)
Commande 4 : FRI 1562 Hz 1008 Hz 1562 Hz 1562 Hz
Commande 5 : TDI Inactif Actif Inactif Inactif
Données non applicables pour ce transducteur/ce mode.
English Deutsch Español Fraais Italiano Português
Puissance acoustique 59
Nederlands
Tableau 13 : Modèle de sonde : rP19xp Mode de fonctionnement : Doppler continu (CW)
Libellé de l’indice IM
ITM ITO
ITC
Balayage
Fixe
Fixe
A
ouac
1
A
ouac
>
1
Valeur de l’indice maximal global (a) 1,2 4,0 3,1
Paramètre acoustique
associé
p
r.3
(MPa) #
W
0
(mW) 130,6 134,7 125,7
min de
[W
.3
(z
1
),I
TA.3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm) 3,40
z@PII
.3max
#
d
eq
(z
sp
) (cm) 0,47
F
c
(MHz) # 2,00 2,00 2,00
Dim de A
ouac
X (cm) 0,90 0,90 0,72
Y (cm) 1,15 1,15 1,15
Autres informations
PD (μs) #
FRI (Hz) #
p
r
@PII
max
(MPa) #
d
eq
@Pll
max
(cm) 0,47
Longueur focale LF
x
(cm) 22,01 1,30
LF
y
(cm) 9,00 9,00
I
MI.3
@IM
max
(W/cm
2
)
#
Conditions
Commande
de fonctionnement
Commande 1 : Type d’examen Crd Crd Crd
Commande 2 : Position du volume
d’échantillon
Zone 11
(220 mm)
Zone 10
(189 mm)
Zone 0
(13 mm)
(a) Cet indice n’est pas nécessaire pour ce mode de fonctionnement, la valeur est <1.
Aucune donnée n’est fournie pour ce mode de fonctionnement, dans la mesure où la valeur de l’indice maximal global
n’est pas rapportée pour la raison indiquée. (Ligne Valeur de l’indice maximal global de référence.)
Données non applicables pour ce transducteur/ce mode.
60 Puissance acoustique
Tableau 14 : Modèle de sonde : rP19xp (utilisation orbitale) Mode de fonctionnement : 2D
Libellé de l’indice IM
ITM ITO
ITC
Balayage
Fixe
Fixe
A
ouac
1 A
ouac
>1
Valeur de l’indice maximal global 0,17 0,026 0,057
Paramètre acoustique
associé
p
r.3
(MPa) 0,26
W
0
(mW) 2,35 3,88
min de
[W
.3
(z
1
),I
TA.3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm)
z@PII
.3max
4,00
d
eq
(z
sp
) (cm)
F
c
(MHz) 2,34 2,33 2,34
Dim de A
ouac
X (cm) 1,92 1,92
Y (cm) 1,15 1,15
Autres informations
PD (μs) 0,59
FRI (Hz) 2317
p
r
@PII
max
(MPa) 0,45
d
eq
@Pll
max
(cm)
Longueur focale LF
x
(cm) 16,77 16,77
LF
y
(cm) 9,00 9,00
I
MI.3
@IM
max
(W/cm
2
)
3,41
Conditions
Commande
de fonctionnement
Commande 1 : Type d’examen Orb Orb Orb
Commande 2 : Optimisation Gén Gén Gén
Commande 3 : Profondeur 31 cm 31 cm 31 cm
Commande 4 : THI Inactif Inactif Inactif
Données non applicables pour ce transducteur/ce mode.
English Deutsch Español Fraais Italiano Português
Puissance acoustique 61
Nederlands
Tableau 15 : Modèle de sonde : rP19xp (utilisation orbitale) Mode de fonctionnement : M Mode
Libellé de l’indice IM
ITM ITO
ITC
Balayage
Fixe
Fixe
A
ouac
1 A
ouac
>1
Valeur de l’indice maximal global 0,17 0,025 0,012 0,055
Paramètre acoustique
associé
p
r.3
(MPa) 0,26
W
0
(mW) 1,848 0,84 3,68
min de
[W
.3
(z
1
),I
TA.3
(z
1
)]
(mW) 0,41
z
1
(cm) 2,80
Z
bp
(cm) 2,52
Z
sp
(cm) 3,8
z@PII
.3max
4,00
d
eq
(z
sp
) (cm) 0,85
F
c
(MHz) 2,34 2,37 2,37 2,34 2,37
Dim de A
ouac
X (cm) 1,92 1,92 1,92 1,92
Y (cm) 1,15 1,15 1,15 1,15
Autres informations
PD (μs) 0,59
FRI (Hz) 1600
p
r
@PII
max
(MPa) 0,45
d
eq
@Pll
max
(cm) 0,58
Longueur focale LF
x
(cm) 14,0 14,0 14,0
LF
y
(cm) 9,0 9,0 9,0
I
MI.3
@IM
max
(W/cm
2
)
3,41
Conditions
Commande
de fonctionnement
Commande 1 : Type d’examen Orb Orb Orb Orb
Commande 2 : Optimisation Gén Gén Gén Gén
Commande 3 : Profondeur 31 cm 25 cm 31 cm 25 cm
Commande 4 : THI Inactif Inactif Inactif Inactif
Données non applicables pour ce transducteur/ce mode.
62 Puissance acoustique
Tableau 16 : Modèle de sonde : rP19xp (utilisation orbitale) Mode de fonctionnement :
Couleur/CPD
Libellé de l’indice IM
ITM ITO
ITC
Balayage
Fixe
Fixe
A
ouac
1
A
ouac
>1
Valeur de l’indice maximal global 0,20 0,055 0,12
Paramètre acoustique
associé
p
r.3
(MPa) 0,28
W
0
(mW) 5,55 5,77
min de
[W
.3
(z
1
),I
TA.3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm)
z@PII
.3max
0,4
d
eq
(z
sp
) (cm)
F
c
(MHz) 2,07 2,068 2,068
Dim de A
ouac
X (cm) 0,96 0,96
Y (cm) 1,15 1,15
Autres informations
PD (μs) 1,55
FRI (Hz) 6301
p
r
@PII
max
(MPa) 0,29
d
eq
@Pll
max
(cm)
Longueur focale LF
x
(cm) 1,3 1,3
LF
y
(cm) 9,0 9,0
I
MI.3
@IM
max
(W/cm
2
)
2,58
Conditions
Commande
de fonctionnement
Commande 1 : Type d’examen Orb Orb Orb
Commande 2 : Mode CVD CVD CVD
Commande 3 : Optimisation/
Profondeur 2D
Gén/5 cm Gén/5 cm Gén/
5
cm
Commande 4 : Optimisation des
couleurs/FRI
Moyen/
2778 Hz
Moy/
2778 Hz
Moy/
2778 Hz
Commande 5 : Position/Taille de la
zone Couleur
Par défaut/
Haut
Par
défaut/
Haut
Par
défaut/
Haut
Données non applicables pour ce transducteur/ce mode.
English Deutsch Español Fraais Italiano Português
Puissance acoustique 63
Nederlands
Tableau 17 : Modèle de sonde : rP19xp (utilisation orbitale) Mode de fonctionnement : Doppler
pulsé (PW)
Libellé de l’indice IM
ITM ITO
ITC
Balayage
Fixe
Fixe
A
ouac
1
A
ouac
>1
Valeur de l’indice maximal global 0,19 0,22 0,56 0,51
Paramètre acoustique
associé
p
r.3
(MPa) 0,28
W
0
(mW) 33,8 34,4
min de
[W
.3
(z
1
),I
TA.3
(z
1
)]
(mW) 21,89
z
1
(cm) 3,00
Z
bp
(cm) 2,52
Z
sp
(cm) 3,8
z@PII
.3max
0,8
d
eq
(z
sp
) (cm) 0,79
F
c
(MHz) 2,11 2,09 2,09 2,09
Dim de A
ouac
X (cm) 1,92 1,92 1,92
Y (cm) 1,15 1,15 1,15
Autres informations
PD (μs) 3,67
FRI (Hz) 3906
p
r
@PII
max
(MPa) 0,29
d
eq
@Pll
max
(cm) 0,69
Longueur focale LF
x
(cm) 22,0 27,3
LF
y
(cm) 9,0 9,0
I
MI.3
@IM
max
(W/cm
2
)
2,43
Conditions
Commande
de fonctionnement
Commande 1 : Type d’examen Orb Orb Orb Orb
Commande 2 : Taille du volume
d’échantillon
3 mm 9 mm 9 mm 7 mm
Commande 3 : Position du
volume d’échantillon
Zone 1
(23 mm)
Zone 11
(220 mm)
Zone 11
(220 mm)
Zone 13
(273 mm)
Commande 4 : FRI 3906 Hz 2604 Hz 2604 Hz 1953 Hz
Données non applicables pour ce transducteur/ce mode.
64 Puissance acoustique
English Deutsch Español Fraais Italiano Português
Introduzione 65
Nederlands
Supplemento al manuale per l’utente del
trasduttore rP19xp X-Porte SonoSite
Introduzione ................................................................................................................................................. 65
Convenzioni della documentazione ............................................................................................................................................... 65
Aiuti ................................................................................................................................................................................................................ 66
Modalità di acquisizione delle immagini .................................................................................................. 67
Pulizia e disinfezione .................................................................................................................................. 68
Sicurezza ...................................................................................................................................................... 68
Accessori e periferiche compatibili ................................................................................................................................................. 69
Uscita acustica ............................................................................................................................................. 69
Linee guida per la riduzione degli indici IM e IT ..................................................................................................................... 69
Visualizzazione dell’uscita ................................................................................................................................................................... 70
Tabelle dell’uscita acustica .................................................................................................................................................................. 71
Introduzione
Questo supplemento al manuale dell’utente fornisce informazioni sul trasduttore rP19xp, compatibile con i
sistemi ecografici X-Porte SonoSite.
Convenzioni della documentazione
Nel documento vengono utilizzate le seguenti convenzioni:
Le note di AVVERTENZA descrivono le precauzioni necessarie per evitare lesioni o il decesso.
Le note di Attenzione descrivono le precauzioni necessarie per evitare danni ai prodotti.
Una Nota fornisce ulteriori informazioni.
Le fasi numerate o marcate con lettera vanno eseguite nell’ordine specificato.
Gli elenchi puntati presentano le informazioni in formato elenco; tuttavia, ciò non implica necessariamente
una sequenza.
Per una descrizione dei simboli delle etichette presenti sul prodotto, consultare “Simboli delle etichette” nel
manuale dell’utente del sistema ecografico.
66 Introduzione
Aiuti
Per assistenza tecnica, contattare FUJIFILM SonoSite come segue:
Stampato negli USA.
Telefono
(USA o Canada)
+1-877-657-8118
Telefono
(altri Paesi)
+1-425-951-1330 oppure rivolgersi al rappresentante
locale
Fax +1-425-951-6700
E-mail ffss-service@fujifilm.com
Internet www.sonosite.com
Centro di assistenza
per l’Europa
Principale: +31 20 751 2020
Assistenza in lingua inglese: +44 14 6234 1151
Assistenza in lingua francese: +33 1 8288 0702
Assistenza in lingua tedesca: +49 69 8088 4030
Assistenza in lingua italiana: +39 02 9475 3655
Assistenza in lingua spagnola: +34 91 123 8451
Centro di assistenza
per l’Asia
+65 6380-5581
English Deutsch Español Fraais Italiano Português
Modalità di acquisizione delle immagini 67
Nederlands
Modalità di acquisizione delle immagini
Tabella 1: Tipi di esami disponibili e modalità di imaging
Trasduttore
Tipo di
esame
Modalità di acquisizione delle immagini
2D
M Mode
Colore
a
Doppler
PW
b
Doppler
CW
rP19xp Addome CVD, CPD
Cardiaco CVD, Var
Polm CVD, CPD
Ostetricia CVD, CPD
Orbitale CVD, CPD
Transcranico CVD, CPD
a
Var = Color Doppler Variance, disponibile solo nell’esame cardiaco. CPD = Color Power Doppler,
disponibile in tutti gli esami ad eccezione del tipo di esame cardiaco. CVD = Color Velocity Doppler.
b
Per il tipo di esame cardiaco, è inoltre disponibile PW TDI.
Nota Il trasduttore rP19xp supporta la guida per ago. Per ulteriori informazioni, fare
riferimento a Using CIVCO Products with FUJIFILM SonoSite Systems (Utilizzo dei
prodotti CIVCO con i sistemi FUJIFILM SonoSite).
68 Pulizia e disinfezione
Pulizia e disinfezione
Sicurezza
Tabella 2: Detergenti approvati
Prodotto Trasduttore compatibile
Tempo di contatto minimo
a
SaniCloth AF3
b
rP19xp 3 minuti
PI-Spray II rP19xp 10 minuti
a
Per la massima efficacia, il componente pulito deve restare bagnato di disinfettante per un periodo di tempo
minimo.
b
Approvato per l’uso come disinfettante di livello intermedio per Mycobacterium.
Per un elenco più completo dei detergenti e disinfettanti più attuali, fare riferimento alla documentazione relativa a
detergenti e disinfettanti disponibile all’indirizzo www.sonosite.com.
Tabella 3: Disinfettanti compatibili di alto livello approvati
Disinfettante
a
Trasduttore compatibile Temperatura
Durata immersione nel
disinfettante
Cidex rP19xp
25
o
C
45 minuti
Cidex OPA rP19xp
20
o
C
12 minuti
a
Per un elenco più completo dei detergenti e disinfettanti più attuali, fare riferimento alla documentazione relativa a
detergenti e disinfettanti disponibile all’indirizzo www.sonosite.com.
AVVE RTE NZ A Per evitare danni al dispositivo o lesioni al paziente, non utilizzare la staffa con
guida per ago rP19xp su pazienti portatori di pacemaker o protesi
elettromedicali. La staffa con guida per ago per rP19xp contiene un magnete
utilizzato per garantire il corretto orientamento della staffa sul trasduttore. Il
campo magnetico in diretta prossimità con il pacemaker o impianto
elettronico medicale potrebbe avere un effetto negativo.
English Deutsch Español Fraais Italiano Português
Uscita acustica 69
Nederlands
Accessori e periferiche compatibili
Uscita acustica
Linee guida per la riduzione degli indici IM e IT
Tabella 4: Accessori e periferiche
Descrizione Lunghezza massima del cavo
Trasduttore rP19xp
a
1,8 m
a
Per i trasduttori, la lunghezza massima del cavo è misurata tra i fermacavo. Le lunghezze stabilite non includono le
lunghezze di cavo nelle seguenti posizioni: al di sotto dei fermacavo, all’interno del perimetro del trasduttore o all’in-
terno del connettore del trasduttore.
Tabella 5: Linee guida per la riduzione dell’indice meccanico (IM)
Trasduttore Profondità
rP19xp
Diminuire o abbassare l’impostazione del parametro per ridurre l’IM.
Aumentare o innalzare l’impostazione del parametro per ridurre l’IM.
70 Uscita acustica
Visualizzazione dell’uscita
Tabella 6: Linee guida per la riduzione dell’indice termico (IT)
Trasduttore
Impostazioni CPD
Imposta-
zioni PW
Lar-
ghezza
casella
Altezza
casella
Profon-
dità
casella
FRI
Profon-
dità
Ottimiz-
zazione
rP19xp
(FRI)
Diminuire o abbassare l’impostazione del parametro per ridurre l’IT.
Aumentare o innalzare l’impostazione del parametro per ridurre l’IT.
Tabella 7: IT o IM 1,0
Trasduttore Indice
2D/
M Mode
CPD/
Colore
Doppler
PW
Doppler
CW
rP19xp IM No
ITC, ITO o ITT
Tabella 8: Aumento della temperatura superficiale del trasduttore, uso esterno (°C )
Test rP19xp
Aria immobile 15,8
Uso simulato 8,8
English Deutsch Español Fraais Italiano Português
Uscita acustica 71
Nederlands
Tabelle dell’uscita acustica
Tabella 9: Modello trasduttore: Modalità operativa dell’rP19xp: 2D
Etichetta indice IM
ITT ITO
ITC
Scan-
sione
Non scansione
Non
scansione
A
aprt
1 A
aprt
>1
Valore indice massimo globale 1,5 1,2 2,9
Parametro acustico
associato
p
r.3
(MPa) 1,95
W
0
(mW) 120,0 190,8
min di [W
.3
(z
1
),
I
TA.3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm)
z@PII
.3max
2,6
d
eq
(z
sp
) (cm)
F
c
(MHz) 1,72 2,02 1,80
Dim di A
aprt
X (cm) 1,92 1,92
Y (cm) 1,15 1,15
Altre informazioni
PD (μsec) 1,227
FRI (Hz) 2933
p
r
@PII
max
(MPa) 2,30
d
eq
@Pll
max
(cm)
Lunghezza focale FL
x
(cm) 3,42 3,42
FL
y
(cm) 9,00 9,00
I
PA.3
@MI
max
(W/cm
2
)
225
Condizioni
controllo
operativo
Controllo 1: Tipo di esame Crd Add Add
Controllo 2: Ottimizzazione Gen Pen Gen
Controllo 3: Profondità 7 cm 5 cm 5 cm
Controllo 4: THI Attivato Disat-
tivato
Attivato
Controllo 5: Larghezza settore Pieno N/A N/A
Dati non applicabili per questa combinazione trasduttore/modalità.
72 Uscita acustica
Tabella 10: Modello trasduttore: Modalità operativa dell’rP19xp: M Mode
Etichetta indice IM
ITT ITO
ITC
Scan-
sione
Non scansione
Non
scansione
A
aprt
1 A
aprt
>1
Valore indice massimo globale 1,5 1,1 0,9 3,0
Parametro acustico
associato
p
r.3
(MPa) 1,95
W
0
(mW) 105 9,8 25,4 180,5
min di [W
.3
(z
1
),
I
TA.3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm) 3,02
z@PII
.3max
2,6
d
eq
(z
sp
) (cm) 0,444
F
c
(MHz) 1,72 2,09 2,09 1,732 1,75
Dim di A
aprt
X (cm) 1,92 0,78 1,02 1,92
Y (cm) 1,15 1,15 1,15 1,15
Altre informazioni
PD (μsec) 1,227
FRI (Hz) 2693
p
r
@PII
max
(MPa) 2,30
d
eq
@Pll
max
(cm) 0,427
Lunghezza focale FL
x
(cm) 4,56 4,56 2,25
FL
y
(cm) 9,00 9,00 9,00
I
PA.3
@MI
max
(W/cm
2
)
225
Condizioni
controllo
operativo
Controllo 1: Tipo di esame Crd Add Crd Add
Controllo 2: Ottimizzazione Gen Pen Gen Gen
Controllo 3: Profondità 7 cm 7 cm 13 cm 5 cm
Controllo 4: THI Attivato Disatti-
vato
Attivato Attivato
Dati non applicabili per questa combinazione trasduttore/modalità.
English Deutsch Español Fraais Italiano Português
Uscita acustica 73
Nederlands
Tabella 11: Modello trasduttore: Modalità operativa dell’rP19xp: Colore/CPD
Etichetta indice IM
ITT ITO
ITC
Scan-
sione
Non scansione
Non
scansione
A
aprt
1 A
aprt
>1
Valore indice massimo globale 1,5 1,6 3,8
Parametro acustico
associato
p
r.3
(MPa) 2,15
W
0
(mW) 134,3 174,1
min di [W
.3
(z
1
),
I
TA.3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm)
z@PII
.3max
4,3
d
eq
(z
sp
) (cm)
F
c
(MHz) 2,05 2,60 2,09
Dim di A
aprt
X (cm) 1,34 0,63
Y (cm) 1,15 1,15
Altre informazioni
PD (μsec) 1,662
FRI (Hz) 1526
p
r
@PII
max
(MPa) 2,91
d
eq
@Pll
max
(cm)
Lunghezza focale FL
x
(cm) 4,56 2,25
FL
y
(cm) 9,00 9,00
I
PA.3
@MI
max
(W/cm
2
)
355
Condizioni
controllo
operativo
Controllo 1: Tipo di esame Polm OS Crd
Controllo 2: Modalità CVD CVD CVD
Controllo 3: Ottimizzazione/
profondità 2D
Gen/
13 cm
Gen/
5 cm
Pen/
5 cm
Controllo 4: Larghezza settore/
THI
N/A N/A/Off Medio/
On
Controllo 5: Ottimizzazione
colore/FRI
Basso/
273 Hz
Alto/
2841 Hz
Alto/
3571 Hz
Controllo 6: Posizione/dimensioni
della casella colore
Def/Stretta Fondo/
Piccolo
Def/
Stretta
Dati non applicabili per questa combinazione trasduttore/modalità.
74 Uscita acustica
Tabella 12: Modello trasduttore: Modalità operativa dell’rP19xp: Doppler PW
Etichetta indice IM
ITT ITO
ITC
Scan-
sione
Non scansione
Non
scansione
A
aprt
1 A
aprt
>1
Valore indice massimo globale 1,5 1,9 4,0 3,2
Parametro acustico
associato
p
r.3
(MPa) 2,17
W
0
(mW) 192,5 211,8
min di [W
.3
(z
1
),
I
TA.3
(z
1
)]
(mW) 108,3
z
1
(cm) 1,9
Z
bp
(cm) 2,5
Z
sp
(cm) 5,10
z@PII
.3max
0,5
d
eq
(z
sp
) (cm) 0,60
F
c
(MHz) 2,08 3,69 2,06 2,04
Dim di A
aprt
X (cm) 1,92 1,92 1,92
Y (cm) 1,15 1,15 1,15
Altre informazioni
PD (μsec) 1,141
FRI (Hz) 1562
p
r
@PII
max
(MPa) 2,24
d
eq
@Pll
max
(cm) 0,54
Lunghezza focale FL
x
(cm) 11,51 11,51
FL
y
(cm) 9,00 9,00
I
PA.3
@MI
max
(W/cm
2
)
156
Condizioni
controllo
operativo
Controllo 1: Tipo di esame Add Crd Add Add
Controllo 2: Dimensioni volume
campione
1 mm 7 mm 1 mm 1 mm
Controllo 3: Posizione volume
campione
Zona 0
(13 mm)
Zona 7
(115 mm)
Zona 6
(96 mm)
Zona 7
(115 mm)
Controllo 4: FRI 1562 Hz 1008 Hz 1562 Hz 1562 Hz
Controllo 5: TDI Disatti-
vato
Attivato Disattivato Disatti-
vato
Dati non applicabili per questa combinazione trasduttore/modalità.
English Deutsch Español Fraais Italiano Português
Uscita acustica 75
Nederlands
Tabella 13: Modello trasduttore: Modalità operativa dell’rP19xp: Doppler CW
Etichetta indice IM
ITT ITO
ITC
Scan-
sione
Non scansione
Non
scansione
A
aprt
1 A
aprt
>1
Valore indice massimo globale (a) 1,2 4,0 3,1
Parametro acustico
associato
p
r.3
(MPa) #
W
0
(mW) 130,6 134,7 125,7
min di [W
.3
(z
1
),
I
TA.3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm) 3,40
z@PII
.3max
#
d
eq
(z
sp
) (cm) 0,47
F
c
(MHz) # 2,00 2,00 2,00
Dim di A
aprt
X (cm) 0,90 0,90 0,72
Y (cm) 1,15 1,15 1,15
Altre informazioni
PD (μsec) #
FRI (Hz) #
p
r
@PII
max
(MPa) #
d
eq
@Pll
max
(cm) 0,47
Lunghezza focale FL
x
(cm) 22,01 1,30
FL
y
(cm) 9,00 9,00
I
PA.3
@MI
max
(W/cm
2
)
#
Condizioni
controllo
operativo
Controllo 1: Tipo di esame Crd Crd Crd
Controllo 2: Posizione volume
campione
Zona 11
(220 mm)
Zona 10
(189 mm)
Zona 0
(13 mm)
(a) Questo indice non è richiesto per questa modalità operativa, il valore è < 1.
# Non sono riportati dati per questa condizione di funzionamento poiché non è registrato il valore dell’indice
massimo globale per il motivo elencato (riga di riferimento del valore dell’indice massimo globale).
Dati non applicabili per questa combinazione trasduttore/modalità.
76 Uscita acustica
Tabella 14: Modello trasduttore: Modalità operativa dell’rP19xp (uso orbitale): 2D
Etichetta indice IM
ITT ITO
ITC
Scan-
sione
Non scansione
Non
scansione
A
aprt
1 A
aprt
>1
Valore indice massimo globale 0,17 0,026 0,057
Parametro acustico
associato
p
r.3
(MPa) 0,26
W
0
(mW) 2,35 3,88
min di [W
.3
(z
1
),
I
TA.3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm)
z@PII
.3max
4,00
d
eq
(z
sp
) (cm)
F
c
(MHz) 2,34 2,33 2,34
Dim di A
aprt
X (cm) 1,92 1,92
Y (cm) 1,15 1,15
Altre informazioni
PD (μsec) 0,59
FRI (Hz) 2317
p
r
@PII
max
(MPa) 0,45
d
eq
@Pll
max
(cm)
Lunghezza focale FL
x
(cm) 16,77 16,77
FL
y
(cm) 9,00 9,00
I
PA.3
@MI
max
(W/cm
2
)
3,41
Condizioni
controllo
operativo
Controllo 1: Tipo di esame Orb Orb Orb
Controllo 2: Ottimizzazione Gen Gen Gen
Controllo 3: Profondità 31 cm 31 cm 31 cm
Controllo 4: THI Disattivato Disat-
tivato
Disatti-
vato
Dati non applicabili per questa combinazione trasduttore/modalità.
English Deutsch Español Fraais Italiano Português
Uscita acustica 77
Nederlands
Tabella 15: Modello trasduttore: Modalità operativa dell’rP19xp (uso orbitale): M Mode
Etichetta indice IM
ITT ITO
ITC
Scan-
sione
Non scansione
Non
scansione
A
aprt
1 A
aprt
>1
Valore indice massimo globale 0,17 0,025 0,012 0,055
Parametro acustico
associato
p
r.3
(MPa) 0,26
W
0
(mW) 1,848 0,84 3,68
min di [W
.3
(z
1
),
I
TA.3
(z
1
)]
(mW) 0,41
z
1
(cm) 2,80
Z
bp
(cm) 2,52
Z
sp
(cm) 3,8
z@PII
.3max
4,00
d
eq
(z
sp
) (cm) 0,85
F
c
(MHz) 2,34 2,37 2,37 2,34 2,37
Dim di A
aprt
X (cm) 1,92 1,92 1,92 1,92
Y (cm) 1,15 1,15 1,15 1,15
Altre informazioni
PD (μsec) 0,59
FRI (Hz) 1600
p
r
@PII
max
(MPa) 0,45
d
eq
@Pll
max
(cm) 0,58
Lunghezza focale FL
x
(cm) 14,0 14,0 14,0
FL
y
(cm) 9,0 9,0 9,0
I
PA.3
@MI
max
(W/cm
2
)
3,41
Condizioni
controllo
operativo
Controllo 1: Tipo di esame Orb Orb Orb Orb
Controllo 2: Ottimizzazione Gen Gen Gen Gen
Controllo 3: Profondità 31 cm 25 cm 31 cm 25 cm
Controllo 4: THI Disattivato Disattivato Disattivato Disatti-
vato
Dati non applicabili per questa combinazione trasduttore/modalità.
78 Uscita acustica
Tabella 16: Modello trasduttore: Modalità operativa dell’rP19xp (uso orbitale): Colore/CPD
Etichetta indice IM
ITT ITO
ITC
Scan-
sione
Non scansione
Non
scansione
A
aprt
1 A
aprt
>1
Valore indice massimo globale 0,20 0,055 0,12
Parametro acustico
associato
p
r.3
(MPa) 0,28
W
0
(mW) 5,55 5,77
min di [W
.3
(z
1
),
I
TA.3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm)
z@PII
.3max
0,4
d
eq
(z
sp
) (cm)
F
c
(MHz) 2,07 2,068 2,068
Dim di A
aprt
X (cm) 0,96 0,96
Y (cm) 1,15 1,15
Altre informazioni
PD (μsec) 1,55
FRI (Hz) 6301
p
r
@PII
max
(MPa) 0,29
d
eq
@Pll
max
(cm)
Lunghezza focale FL
x
(cm) 1,3 1,3
FL
y
(cm) 9,0 9,0
I
PA.3
@MI
max
(W/cm
2
)
2,58
Condizioni
controllo
operativo
Controllo 1: Tipo di esame Orb Orb Orb
Controllo 2: Modalità CVD CVD CVD
Controllo 3: Ottimizzazione/
profondità 2D
Gen/5 cm Gen/
5
cm
Gen/
5
cm
Controllo 4: Ottimizzazione colore/
FRI
Medio/
2778 Hz
Med/
2778 Hz
Med/
2778 Hz
Controllo 5: Posizione/dimensioni
della casella colore
Predefinito/
In alto
Predefi-
nito/In
alto
Predefi-
nito/In
alto
Dati non applicabili per questa combinazione trasduttore/modalità.
English Deutsch Español Fraais Italiano Português
Uscita acustica 79
Nederlands
Tabella 17: Modello trasduttore: Modalità operativa dell’rP19xp (uso orbitale): Doppler PW
Etichetta indice IM
ITT ITO
ITC
Scan-
sione
Non scansione
Non
scansione
A
aprt
1 A
aprt
>1
Valore indice massimo globale 0,19 0,22 0,56 0,51
Parametro acustico
associato
p
r.3
(MPa) 0,28
W
0
(mW) 33,8 34,4
min di [W
.3
(z
1
),
I
TA.3
(z
1
)]
(mW) 21,89
z
1
(cm) 3,00
Z
bp
(cm) 2,52
Z
sp
(cm) 3,8
z@PII
.3max
0,8
d
eq
(z
sp
) (cm) 0,79
F
c
(MHz) 2,11 2,09 2,09 2,09
Dim di A
aprt
X (cm) 1,92 1,92 1,92
Y (cm) 1,15 1,15 1,15
Altre informazioni
PD (μsec) 3,67
FRI (Hz) 3906
p
r
@PII
max
(MPa) 0,29
d
eq
@Pll
max
(cm) 0,69
Lunghezza focale FL
x
(cm) 22,0 27,3
FL
y
(cm) 9,0 9,0
I
PA.3
@MI
max
(W/cm
2
)
2,43
Condizioni
controllo
operativo
Controllo 1: Tipo di esame Orb Orb Orb Orb
Controllo 2: Dimensioni volume
campione
3 mm 9 mm 9 mm 7 mm
Controllo 3: Posizione volume
campione
Zona 1
(23 mm)
Zona 11
(220 mm)
Zona 11
(220 mm)
Zona 13
(273 mm)
Controllo 4: FRI 3906 Hz 2604 Hz 2604 Hz 1953 Hz
Dati non applicabili per questa combinazione trasduttore/modalità.
80 Uscita acustica
English Deutsch Español Fraais Italiano Português
Introdução 81
Nederlands
Suplemento do guia do usuário do transdutor
SonoSite X-Porte rP19xp
Introdução .................................................................................................................................................... 81
Convenções do documento ............................................................................................................................................................... 81
Para obter ajuda ....................................................................................................................................................................................... 82
Modos de geração de imagens .................................................................................................................. 83
Limpeza e desinfecção ............................................................................................................................... 84
Segurança ..................................................................................................................................................... 84
Acessórios e periféricos compatíveis ............................................................................................................................................ 85
Saída acústica .............................................................................................................................................. 85
Diretrizes para redução de IM e IT ................................................................................................................................................. 85
Exibição da saída ..................................................................................................................................................................................... 86
Tabelas de saída acústica .................................................................................................................................................................... 87
Introdução
Este suplemento do guia do usuário fornece informações sobre o transdutor rP19xp, compatível com o
sistema de ultrassom SonoSite X-Porte.
Convenções do documento
O documento segue estas convenções:
Um AVISO descreve as precauções necessárias para evitar ferimentos ou morte.
Um aviso de Cuidado descreve as precauções necessárias para proteger os produtos.
Uma Observação fornece informações complementares.
As etapas numeradas e organizadas por letras devem ser realizadas em uma ordem específica.
As listas com marcadores apresentam informações em formato de lista, mas não implicam uma sequência.
Para ver a descrição dos símbolos de rotulagem que aparecem no produto, consulte “Identificação dos
símbolos” no manual do usuário do sistema de ultrassom.
82 Introdução
Para obter ajuda
Para assistência técnica, entre em contato com a FUJIFILM SonoSite das seguintes formas:
Impresso nos EUA.
Telefone
(EUA ou Canadá)
+1-877-657-8118
Telefone
(fora dos EUA ou do
Canadá)
+1-425-951-1330, ou ligue para seu representante local
Fax +1-425-951-6700
E-mail ffss-service@fujifilm.com
Web www.sonosite.com
Centro de manutenção
da Europa
Principal: +31 20 751 2020
Suporte em inglês: +44 14 6234 1151
Suporte em francês: +33 1 8288 0702
Suporte em alemão: +49 69 8088 4030
Suporte em italiano: +39 02 9475 3655
Suporte em espanhol: +34 91 123 8451
Centro de manutenção
da Ásia
+65 6380-5581
English Deutsch Español Fraais Italiano Português
Modos de geração de imagens 83
Nederlands
Modos de geração de imagens
Tabela 1: Tipos de exame e modos de geração de imagem disponíveis
Transdutor
Tipo de
exame
Modo de geração de imagens
2D
M Mode
Colorido
a
Doppler
PW
b
Doppler
CW
rP19xp Abdome CVD, CPD
Cardíaco CVD, Var
Pulmão CVD, CPD
Obstetrícia CVD, CPD
Orbital CVD, CPD
Transcraniano CVD, CPD
a
Var = variação de Doppler colorido, que está disponível somente no exame cardíaco. CPD = Power
Doppler Colorido, que está disponível em todos os exames, exceto no tipo de exame cardíaco. CVD =
Velocity Doppler colorido.
b
Para o tipo de exame cardíaco, o PW TDI também se encontra disponível.
Observação O transdutor rP19xp tem capacidade para guia de agulha. Para obter mais
informações, consulte a Using CIVCO Products with FUJIFILM SonoSite
Systems (Utilização de produtos CIVCO com sistemas FUJIFILM SonoSite).
84 Limpeza e desinfecção
Limpeza e desinfecção
Segurança
Tabela 2: Produtos de limpeza aprovados
Produto Transdutor compatível
Tempo mínimo de contato
úmido
a
SaniCloth AF3
b
rP19xp 3 minutos
PI-Spray II rP19xp 10 minutos
a
Para a eficácia máxima, o componente que está sendo limpo deve permanecer molhado com o desinfetante por
um período mínimo de tempo.
b
Qualificado para uso como desinfetante de nível intermediário para micobactérias.
Consulte o documento relacionado aos produtos de limpeza e desinfetantes disponível em www.sonosite.com
para obter a lista completa dos produtos de limpeza e desinfetantes mais recentes.
Tabela 3: Desinfetantes de alto nível compatíveis aprovados
Desinfetante
a
Transdutor compatível Temperatura
Duração da imersão em
desinfetante
Cidex rP19xp 25 °C 45 minutos
Cidex OPA rP19xp 20 °C 12 minutos
a
Consulte o documento relacionado aos produtos de limpeza e desinfetantes disponível emwww.sonosite.com
para obter a lista completa dos produtos de limpeza e desinfetantes mais recentes.
AVISO Para evitar danos ao dispositivo ou ferimentos ao paciente, não use o suporte de
guia de agulha rP19xp em pacientes com marca-passo ou implantes eletrônicos
médicos. O suporte de guia de agulha para rP19xp contém um ímã usado para
garantir que o suporte esteja orientado corretamente no transdutor. O campo
magnético muito próximo do marca-passo ou implante médico eletrônico pode
causar um efeito adverso.
English Deutsch Español Fraais Italiano Português
Saída acústica 85
Nederlands
Acessórios e periféricos compatíveis
Saída acústica
Diretrizes para redução de IM e IT
Tabela 4: Acessórios e periféricos
Descrição Comprimento máximo do cabo
transdutor rP19xp
a
1,8 m
a
Para transdutores, o comprimento máximo do cabo é medido entre os redutores de tensão. Os comprimentos de-
clarados não incluem os comprimentos dos cabos nos seguintes locais: debaixo dos redutores de tensão, dentro do
compartimento do transdutor ou dentro do conector do transdutor.
Tabela 5: Diretrizes para reduzir o índice mecânico (IM)
Transdutor Profundidade
rP19xp
Reduza ou abaixe o valor do parâmetro para reduzir o IM.
Aumente ou eleve o valor do parâmetro para reduzir o IM.
86 Saída acústica
Exibição da saída
Tabela 6: Diretrizes para reduzir o índice térmico (IT)
Transdutor
Configurações CPD
Configu-
rações
de DP
Largura
da caixa
Altura da
caixa
Profundi-
dade da
caixa
PRF
Profundi-
dade
Otimizar
rP19xp
(PRF)
Reduza ou abaixe o valor do parâmetro para reduzir o IT.
Aumente ou eleve o valor do parâmetro para reduzir o IT.
Tabela 7: IT ou IM 1,0
Transdutor Índice
2D/
M Mode
CPD/
Cores
Doppler
PW
Doppler
CW
rP19xp IM Sim Sim Sim Não
ITC, ITO ou ITM Sim Sim Sim Sim
Tabela 8: Aumento de temperatura na superfície do transdutor, uso externo (°C )
Teste rP19xp
Ar parado 15,8
Uso simulado 8,8
English Deutsch Español Fraais Italiano Português
Saída acústica 87
Nederlands
Tabelas de saída acústica
Tabela 9: Modelo do transdutor: rP19xp Modo de operação: 2D
Rótulo do índice IM
ITM ITO
ITC
Varre-
dura
Sem varredura
Sem
varredura
A
abt
1 A
abt
>1
Valor do índice máximo global 1,5 1,2 2,9
Parâmetro acústico
associado
p
r.3
(MPa) 1,95
W
0
(mW) 120,0 190,8
mín. de [W
0,3
(z
1
),
I
TA.3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm)
z@PII
0,3 máx.
2,6
d
eq
(z
sp
) (cm)
F
c
(MHz) 1,72 2,02 1,80
Dim de A
abt
X (cm) 1,92 1,92
Y (cm) 1,15 1,15
Outras informações
PD (μs) 1,227
PRF (Hz) 2933
p
r
@PII
máx.
(MPa) 2,30
d
eq
@Pll
máx.
(cm)
Comprimento focal CF
x
(cm) 3,42 3,42
CF
y
(cm) 9,00 9,00
I
PA.3
@IM
máx
(W/cm
2
)
225
Condições
Controle
de operação
Controle 1: Tipo de exame Crd Abd Abd
Controle 2: Otimização Ger Pen Ger
Controle 3: Profundidade 7 cm 5 cm 5 cm
Controle 4: THI Ligado Desli-
gado
Ligado
Controle 5: Largura do setor Cheio N/D N/D
Os dados não são aplicáveis a este transdutor/modo.
88 Saída acústica
Tabela 10: Modelo do transdutor: rP19xp Modo de operação: M Mode
Rótulo do índice IM
ITM ITO
ITC
Varre-
dura
Sem varredura
Sem
varredura
A
abt
1 A
abt
>1
Valor do índice máximo global 1,5 1,1 0,9 3,0
Parâmetro acústico
associado
p
r.3
(MPa) 1,95
W
0
(mW) 105 9,8 25,4 180,5
mín. de [W
0,3
(z
1
),
I
TA.3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm) 3,02
z@PII
0,3 máx.
2,6
d
eq
(z
sp
) (cm) 0,444
F
c
(MHz) 1,72 2,09 2,09 1,732 1,75
Dim de A
abt
X (cm) 1,92 0,78 1,02 1,92
Y (cm) 1,15 1,15 1,15 1,15
Outras informações
PD (μs) 1,227
PRF (Hz) 2693
p
r
@PII
máx.
(MPa) 2,30
d
eq
@Pll
máx.
(cm) 0,427
Comprimento focal CF
x
(cm) 4,56 4,56 2,25
CF
y
(cm) 9,00 9,00 9,00
I
PA.3
@IM
máx
(W/cm
2
)
225
Condições
Controle
de operação
Controle 1: Tipo de exame Crd Abd Crd Abd
Controle 2: Otimização Ger Pen Ger Ger
Controle 3: Profundidade 7 cm 7 cm 13 cm 5 cm
Controle 4: THI Ligado Desli-
gado
Ligado Ligado
Os dados não são aplicáveis a este transdutor/modo.
English Deutsch Español Fraais Italiano Português
Saída acústica 89
Nederlands
Tabela 11: Modelo do transdutor: rP19xp Modo de operação: Cores/CPD
Rótulo do índice IM
ITM ITO
ITC
Varre-
dura
Sem varredura
Sem
varredura
A
abt
1 A
abt
>1
Valor do índice máximo global 1,5 1,6 3,8
Parâmetro acústico
associado
p
r.3
(MPa) 2,15
W
0
(mW) 134,3 174,1
mín. de [W
0,3
(z
1
),
I
TA.3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm)
z@PII
0,3 máx.
4,3
d
eq
(z
sp
) (cm)
F
c
(MHz) 2,05 2,60 2,09
Dim de A
abt
X (cm
)
1,34 0,63
Y (cm
)
1,15 1,15
Outras informações
PD (μs) 1,662
PRF (Hz) 1526
p
r
@PII
máx.
(MPa) 2,91
d
eq
@Pll
máx.
(cm)
Comprimento focal CF
x
(cm)
4,56 2,25
CF
y
(cm)
9,00 9,00
I
PA.3
@IM
máx
(W/
cm
2
)
355
Os dados não são aplicáveis a este transdutor/modo.
90 Saída acústica
Condições
Controle
de operação
Controle 1: Tipo de exame Pulmão OB Crd
Controle 2: Modo CVD CVD CVD
Controle 3: Otimização 2D/
Profundidade
Ger/
13 cm
Ger/
5 cm
Pen/
5 cm
Controle 4: Largura do setor/THI N/D N/A/
Desligado
Méd/
Ligado
Controle 5: Otimização de
cores/PRF
Baixa/
273 Hz
Alto/
2.841 Hz
Alto/
3.571
Hz
Controle 6: Posição/tamanho da
caixa de cores
Pad/
Estreito
Fundo/
Pequeno
Pad/
Estreito
Tabela 11: Modelo do transdutor: rP19xp Modo de operação: Cores/CPD
Rótulo do índice IM
ITM ITO
ITC
Varre-
dura
Sem varredura
Sem
varredura
A
abt
1 A
abt
>1
Os dados não são aplicáveis a este transdutor/modo.
English Deutsch Español Fraais Italiano Português
Saída acústica 91
Nederlands
Tabela 12: Modelo do transdutor: rP19xp Modo de operação: Doppler PW
Rótulo do índice IM
ITM ITO
ITC
Varre-
dura
Sem varredura
Sem
varredura
A
abt
1 A
abt
>1
Valor do índice máximo global 1,5 1,9 4,0 3,2
Parâmetro acústico
associado
p
r.3
(MPa) 2,17
W
0
(mW) 192,5 211,8
mín. de [W
0,3
(z
1
),
I
TA.3
(z
1
)]
(mW) 108,3
z
1
(cm) 1,9
Z
bp
(cm) 2,5
Z
sp
(cm) 5,10
z@PII
0,3 máx.
0,5
d
eq
(z
sp
) (cm) 0,60
F
c
(MHz) 2,08 3,69 2,06 2,04
Dim de A
abt
X (cm) 1,92 1,92 1,92
Y (cm) 1,15 1,15 1,15
Outras informações
PD (μs) 1,141
PRF (Hz) 1562
p
r
@PII
máx.
(MPa) 2,24
d
eq
@Pll
máx.
(cm) 0,54
Comprimento focal CF
x
(cm) 11,51 11,51
CF
y
(cm) 9,00 9,00
I
PA.3
@IM
máx
(W/cm
2
)
156
Condições
Controle
de operação
Controle 1: Tipo de exame Abd Crd Abd Abd
Controle 2: Tamanho do volume
da amostra
1 mm 7 mm 1 mm 1 mm
Controle 3: Posição do volume da
amostra
Zona 0
(13 mm)
Zona 7
(115 mm)
Zona 6
(96 mm)
Zona 7
(115 mm)
Controle 4: PRF 1.562 Hz 1.008 Hz 1.562 Hz 1.562 Hz
Controle 5: TDI Desligado Ligado Desligado Desligado
Os dados não são aplicáveis a este transdutor/modo.
92 Saída acústica
Tabela 13: Modelo do transdutor: rP19xp Modo de operação: Doppler CW
Rótulo do índice IM
ITM ITO
ITC
Varre-
dura
Sem varredura
Sem
varredura
A
abt
1 A
abt
>1
Valor do índice máximo global (a) 1,2 4,0 3,1
Parâmetro acústico
associado
p
r.3
(MPa) #
W
0
(mW) 130,6 134,7 125,7
mín. de [W
0,3
(z
1
),
I
TA.3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm) 3,40
z@PII
0,3 máx.
#
d
eq
(z
sp
) (cm) 0,47
F
c
(MHz) # 2,00 2,00 2,00
Dim de A
abt
X (cm) 0,90 0,90 0,72
Y (cm) 1,15 1,15 1,15
Outras informações
PD (μs) #
PRF (Hz) #
p
r
@PII
máx.
(MPa) #
d
eq
@Pll
máx.
(cm) 0,47
Comprimento focal CF
x
(cm) 22,01 1,30
CF
y
(cm) 9,00 9,00
I
PA.3
@IM
máx
(W/cm
2
)
#
Condições
Controle
de operação
Controle 1: Tipo de exame Crd Crd Crd
Controle 2: Posição do volume da
amostra
Zona 11
(220 mm)
Zona 10
(189 mm)
Zona 0
(13 mm)
(a) Este índice não é exigido para este modo de operação; o valor é <1.
# Não foram relatados dados sobre esta condição de operação uma vez que o valor do índice máximo global não é
relatado para o motivo apresentado. (Linha de referência do valor do índice máximo global.)
Os dados não são aplicáveis a este transdutor/modo.
English Deutsch Español Fraais Italiano Português
Saída acústica 93
Nederlands
Tabela 14: Modelo do transdutor: rP19xp (uso orbital) Modo de operação: 2D
Rótulo do índice IM
ITM ITO
ITC
Varre-
dura
Sem varredura
Sem
varredura
A
abt
1 A
abt
>1
Valor do índice máximo global 0,17 0,026 0,057
Parâmetro acústico
associado
p
r.3
(MPa) 0,26
W
0
(mW) 2,35 3,88
mín. de [W
0,3
(z
1
),
I
TA.3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm)
z@PII
0,3 máx.
4,00
d
eq
(z
sp
) (cm)
F
c
(MHz) 2,34 2,33 2,34
Dim de A
abt
X (cm) 1,92 1,92
Y (cm) 1,15 1,15
Outras informações
PD (μs) 0,59
PRF (Hz) 2.317
p
r
@PII
máx.
(MPa) 0,45
d
eq
@Pll
máx.
(cm)
Comprimento focal CF
x
(cm) 16,77 16,77
CF
y
(cm) 9,00 9,00
I
PA.3
@IM
máx
(W/cm
2
)
3,41
Condições
Controle
de operação
Controle 1: Tipo de exame Orb Orb Orb
Controle 2: Otimização Ger Ger Ger
Controle 3: Profundidade 31 cm 31 cm 31 cm
Controle 4: THI Desligado Desli-
gado
Desli-
gado
Os dados não são aplicáveis a este transdutor/modo.
94 Saída acústica
Tabela 15: Modelo do transdutor: rP19xp (uso orbital) Modo de operação: M Mode
Rótulo do índice IM
ITM ITO
ITC
Varre-
dura
Sem varredura
Sem
varredura
A
abt
1 A
abt
>1
Valor do índice máximo global 0,17 0,025 0,012 0,055
Parâmetro acústico
associado
p
r.3
(MPa) 0,26
W
0
(mW) 1,848 0,84 3,68
mín. de [W
0,3
(z
1
),
I
TA.3
(z
1
)]
(mW) 0,41
z
1
(cm) 2,80
Z
bp
(cm) 2,52
Z
sp
(cm) 3,8
z@PII
0,3 máx.
4,00
d
eq
(z
sp
) (cm) 0,85
F
c
(MHz) 2,34 2,37 2,37 2,34 2,37
Dim de A
abt
X (cm) 1,92 1,92 1,92 1,92
Y (cm) 1,15 1,15 1,15 1,15
Outras informações
PD (μs) 0,59
PRF (Hz) 1600
p
r
@PII
máx.
(MPa) 0,45
d
eq
@Pll
máx.
(cm) 0,58
Comprimento focal CF
x
(cm) 14,0 14,0 14,0
CF
y
(cm) 9,0 9,0 9,0
I
PA.3
@IM
máx
(W/cm
2
)
3,41
Condições
Controle
de operação
Controle 1: Tipo de exame Orb Orb Orb Orb
Controle 2: Otimização Ger Ger Ger Ger
Controle 3: Profundidade 31 cm 25 cm 31 cm 25 cm
Controle 4: THI Desligado Desligado Desligado Desli-
gado
Os dados não são aplicáveis a este transdutor/modo.
English Deutsch Español Fraais Italiano Português
Saída acústica 95
Nederlands
Tabela 16: Modelo do transdutor: rP19xp (uso orbital) Modo de operação: Cores/CPD
Rótulo do índice IM
ITM ITO
ITC
Varre-
dura
Sem varredura
Sem
varredura
A
abt
1 A
abt
>1
Valor do índice máximo global 0,20 0,055 0,12
Parâmetro acústico
associado
p
r.3
(MPa) 0,28
W
0
(mW) 5,55 5,77
mín. de [W
0,3
(z
1
),
I
TA.3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm)
z@PII
0,3 máx.
0,4
d
eq
(z
sp
) (cm)
F
c
(MHz) 2,07 2,068 2,068
Dim de A
abt
X (cm) 0,96 0,96
Y (cm) 1,15 1,15
Outras informações
PD (μs) 1,55
PRF (Hz) 6301
p
r
@PII
máx.
(MPa) 0,29
d
eq
@Pll
máx.
(cm)
Comprimento focal CF
x
(cm) 1,3 1,3
CF
y
(cm) 9,0 9,0
I
PA.3
@IM
máx
(W/cm
2
)
2,58
Condições
Controle
de operação
Controle 1: Tipo de exame Orb Orb Orb
Controle 2: Modo CVD CVD CVD
Controle 3: Otimização 2D/
Profundidade
Ger/5 cm Ger/
5
cm
Ger/
5
cm
Controle 4: Otimização de cores/
PRF
Méd/
2.778 Hz
Méd/
2.778
Hz
Méd/
2.778
Hz
Controle 5: Posição/tamanho da
caixa de cores
Padrão/
Superior
Padrão/
Superior
Padrão/
Superior
Os dados não são aplicáveis a este transdutor/modo.
96 Saída acústica
Tabela 17: Modelo do transdutor: rP19xp (uso orbital) Modo de operação: Doppler PW
Rótulo do índice IM
ITM ITO
ITC
Varre-
dura
Sem varredura
Sem
varredura
A
abt
1 A
abt
>1
Valor do índice máximo global 0,19 0,22 0,56 0,51
Parâmetro acústico
associado
p
r.3
(MPa) 0,28
W
0
(mW) 33,8 34,4
mín. de [W
0,3
(z
1
),
I
TA.3
(z
1
)]
(mW) 21,89
z
1
(cm) 3,00
Z
bp
(cm) 2,52
Z
sp
(cm) 3,8
z@PII
0,3 máx.
0,8
d
eq
(z
sp
) (cm) 0,79
F
c
(MHz) 2,11 2,09 2,09 2,09
Dim de A
abt
X (cm) 1,92 1,92 1,92
Y (cm) 1,15 1,15 1,15
Outras informações
PD (μs) 3,67
PRF (Hz) 3906
p
r
@PII
máx.
(MPa) 0,29
d
eq
@Pll
máx.
(cm) 0,69
Comprimento focal CF
x
(cm) 22,0 27,3
CF
y
(cm) 9,0 9,0
I
PA.3
@IM
máx
(W/cm
2
)
2,43
Condições
Controle
de operação
Controle 1: Tipo de exame Orb Orb Orb Orb
Controle 2: Tamanho do volume
da amostra
3 mm 9 mm 9 mm 7 mm
Controle 3: Posição do volume da
amostra
Zona 1
(23 mm)
Zona 11
(220 mm)
Zona 11
(220 mm)
Zona 13
(273 mm)
Controle 4: PRF 3.906 Hz 2.604 Hz 2.604 Hz 1.953 Hz
Os dados não são aplicáveis a este transdutor/modo.
Français
English Deutsch Español NederlandsItaliano Portugs
Introductie 97
Supplement bij gebruikershandleiding SonoSite
X-Porte rP19xp-transducer
Introductie .................................................................................................................................................... 97
Conventies in het document ............................................................................................................................................................. 97
Help ................................................................................................................................................................................................................ 98
Beeldvormingsmodi .................................................................................................................................... 99
Reinigen en desinfecteren ....................................................................................................................... 100
Veiligheid .................................................................................................................................................... 100
Compatibele accessoires en randapparatuur ........................................................................................................................ 101
Akoestisch vermogen ............................................................................................................................... 101
Richtlijnen voor het verminderen van MI en TI .................................................................................................................... 101
Vermogensweergave ......................................................................................................................................................................... 102
Tabellen voor akoestisch vermogen ........................................................................................................................................... 103
Introductie
Dit supplement bij gebruikershandleiding biedt informatie over de rP19xp-transducer die compatibel is met
het SonoSite X-Porte ultrasone systeem.
Conventies in het document
Het document volgt deze conventies:
Een WAARSCHUWING beschrijft de voorzorgsmaatregelen die noodzakelijk zijn om letsel of overlijden
te voorkomen.
Let op beschrijft voorzorgsmaatregelen die noodzakelijk zijn om de producten te beschermen.
Een Opmerking geeft aanvullende informatie.
Stappen die van een nummer en letter zijn voorzien, moeten in een specifieke volgorde worden
uitgevoerd.
Lijsten met opsommingstekens geven informatie in lijstvorm weer, maar bevatten geen volgorde.
Raadpleeg ‘Symbolen op labels’ in de gebruikershandleiding van het ultrasone systeem voor een
beschrijving van de labelsymbolen die op het product staan.
98 Introductie
Help
Neem als volgt contact op met FUJIFILM SonoSite voor technische ondersteuning:
Gedrukt in de VS.
Telefoonnummer
(VS of Canada)
+1-877-657-8118
Telefoonnummer
(buiten de VS of
Canada)
+1-425-951-1330 of neem contact op met de plaatselijke
vertegenwoordiger
Fax +1-425-951-6700
E-mail ffss-service@fujifilm.com
Web www.sonosite.com
Europees
servicecentrum
Hoofdtelefoonnr.: +31 20 751 2020
Engelstalige ondersteuning: +44 14 6234 1151
Franstalige ondersteuning: +33 1 8288 0702
Duitstalige ondersteuning: +49 69 8088 4030
Italiaanstalige ondersteuning: +39 02 9475 3655
Spaanstalige ondersteuning: +34 91 123 8451
Servicecentrum voor
Azië
+65 6380-5581
Français
English Deutsch Español NederlandsItaliano Portugs
Beeldvormingsmodi 99
Beeldvormingsmodi
Tabel 1: Beschikbare onderzoekstypen en beeldvormingsmodi
Transducer Onderzoekstype
Beeldvormingsmodus
2D
M Mode
Kleur
a
PW
Doppler
b
CW
Doppler
rP19xp Abdomen CVD, CPD -
Cardiaal CVD, Var
Long CVD, CPD -
Verloskunde CVD, CPD -
Orbitaal CVD, CPD -
Transcraniaal CVD, CPD -
a
Var = Color Doppler Variance en is uitsluitend beschikbaar bij het cardiaal onderzoek. CPD = Color Power
Doppler en is bij alle onderzoeken behalve bij het cardiale onderzoekstype beschikbaar. CVD = Color
Velocity Doppler.
b
PW TDI is ook beschikbaar voor het cardiale onderzoekstype.
Opmerking De rP19xp-transducer kan met een naaldgeleider worden gebruikt. Voor meer
informatie, raadpleeg Using CIVCO Products with FUJIFILM SonoSite Systems
(CIVCO-producten gebruiken met FUJIFILM SonoSite-systemen).
100 Reinigen en desinfecteren
Reinigen en desinfecteren
Veiligheid
Tabel 2: Goedgekeurde reinigingsmiddelen
Product Compatibele transducer
Minimale natte contacttijd
a
SaniCloth AF3
b
rP19xp 3 minuten
PI-Spray II rP19xp 10 minuten
a
Om de effectiviteit maximaal te kunnen benutten, moet het gereinigde onderdeel een minimumperiode nat blijven.
b
Goedgekeurd voor gebruik als een midden-niveau desinfectiemiddel voor mycobacteriën.
Raadpleeg het document met reinigings- en desinfectiemiddelen op www.sonosite.com voor een complete lijst
van de meest recente reinigings- en desinfectiemiddelen.
Tabel 3: Goedgekeurde desinfectiemiddelen van hoog niveau
Desinfectie-
middel
a
Compatibele transducer Temperatuur
Weekduur in
desinfectiemiddel
Cidex rP19xp
25
o
C
45 minuten
Cidex OPA rP19xp
20
o
C
12 minuten
a
Raadpleeg het document met reinigings- en desinfectiemiddelen op www.sonosite.com voor een complete lijst
van de meest recente reinigings- en desinfectiemiddelen.
WAARSCHUWING Gebruik de rP19xp-naaldgeleiderbeugel niet bij patiënten met
pacemakers of medische elektronische implantaten om schade aan het
apparaat of letsel bij de patiënt te voorkomen. De naaldgeleiderbeugel
voor de rP19xp bevat een magneet die wordt gebruikt om ervoor te
zorgen dat de beugel juist op de transducer is geplaatst. Wanneer het
magnetische veld in de directe omgeving van de pacemaker of een
medisch elektronisch implantaat komt, kan dit negatieve gevolgen
hebben.
Français
English Deutsch Español NederlandsItaliano Portugs
Akoestisch vermogen 101
Compatibele accessoires en randapparatuur
Akoestisch vermogen
Richtlijnen voor het verminderen van MI en TI
Tabel 4: Accessoires en randapparatuur
Beschrijving Maximale kabellengte
rP19xp-transducer
a
1,8 m
a
De maximale kabellengte voor transducers wordt gemeten tussen de trekontlastingen. De vermelde lengtes omvat-
ten niet de lengtes van de kabel op de volgende locaties: onder de trekontlastingen, aan de binnenzijde van de trans-
ducerbehuizing of aan de binnenzijde van de transducerconnector.
Tabel 5: Richtlijnen voor het verlagen van de mechanische index (MI)
Transducer Diepte
rP19xp
Verminder of verlaag de instelling van de parameter om MI te verminderen.
Vergroot of verhoog de instelling van de parameter om MI te verminderen.
102 Akoestisch vermogen
Vermogensweergave
Tabel 6: Richtlijnen voor het verlagen van de thermische index (TI)
Transducer
CPD-instellingen
PW-
instellin-
gen
Breedte
vak
Hoogte
vak
Diepte
vak
PRF Diepte
Optima-
liseren
rP19xp
(PRF)
Verminder of verlaag de instelling van de parameter om TI te verminderen.
Vergroot of verhoog de instelling van de parameter om TI te verminderen.
Tabel 7: TI or MI 1,0
Transducer Index
2D/
M Mode
CPD/
Kleur
PW
Doppler
CW
Doppler
rP19xp MI Ja Ja Ja Nee
TIC, TIB of TIS Ja Ja Ja Ja
Tabel 8: Stijging oppervlaktetemperatuur transducer, extern gebruik (°C )
Test rP19xp
Stilstaande lucht 15,8
Gesimuleerd gebruik 8,8
Français
English Deutsch Español NederlandsItaliano Portugs
Akoestisch vermogen 103
Tabellen voor akoestisch vermogen
Tabel 9: Transducermodel: rP19xp Bedieningsmodus: 2D
Indexlabel M.I.
TIS TIB
TIC
Scan
Zonder scan
Zonder
scan
A
aprt
1 A
aprt
>1
Algemene maximale indexwaarde 1,5 1,2 - - - 2,9
Gekoppelde akoestische
parameter
p
r.3
(MPa) 1,95
W
0
(mW) 120,0 - - 190,8
min van [W
.3
(z
1
),
I
TA.3
(z
1
)]
(mW) -
z
1
(cm) -
Z
bp
(cm) -
Z
sp
(cm) -
z@PII
.3max
2,6
d
eq
(z
sp
) (cm) -
F
c
(MHz) 1,72 2,02 - - - 1,80
Dim. van A
aprt
X (cm) 1,92 - - - 1,92
Y (cm) 1,15 - - - 1,15
Overige informatie
PD (μsec) 1,227
PRF (Hz) 2933
p
r
@PII
max
(MPa) 2,30
d
eq
@Pll
max
(cm) -
Brandpuntlengte BPL
x
(cm)
3,42 - - 3,42
BPL
y
(cm)
9,00 - - 9,00
I
PA.3
@MI
max
(W/cm
2
)
225
Bedrijfs-
bedienings-
omstandigheden
Controle 1: Onderzoekstype Crd Abd Abd
Controle 2: Optimalisatie Gen Pen Gen
Controle 3: Diepte 7 cm 5 cm 5 cm
Controle 4: THI Aan Uit Aan
Controle 5: Sectorbreedte Volledig N.v.t. N.v.t.
Gegevens zijn niet van toepassing op deze transducer/modus.
104 Akoestisch vermogen
Tabel 10: Transducermodel: rP19xp Bedieningsmodus: M Mode
Indexlabel M.I.
TIS TIB
TIC
Scan
Zonder scan
Zonder
scan
A
aprt
1 A
aprt
>1
Algemene maximale indexwaarde 1,5 1,1 0,9 3,0
Gekoppelde akoestische
parameter
p
r.3
(MPa) 1,95
W
0
(mW) 105 9,8 25,4 180,5
min van [W
.3
(z
1
),
I
TA.3
(z
1
)]
(mW) -
z
1
(cm) -
Z
bp
(cm) -
Z
sp
(cm) 3,02
z@PII
.3max
2,6
d
eq
(z
sp
) (cm) 0,444
F
c
(MHz) 1,72 2,09 2,09 - 1,732 1,75
Dim. van A
aprt
X (cm) 1,92 0,78 - 1,02 1,92
Y (cm) 1,15 1,15 - 1,15 1,15
Overige informatie
PD (μsec) 1,227
PRF (Hz) 2693
p
r
@PII
max
(MPa) 2,30
d
eq
@Pll
max
(cm) 0,427
Brandpuntlengte BPL
x
(cm)
4,56 4,56 - 2,25
BPL
y
(cm)
9,00 9,00 - 9,00
I
PA.3
@MI
max
(W/cm
2
)
225
Bedrijfs-
bedienings-
omstandigheden
Controle 1: Onderzoekstype Crd Abd Crd Abd
Controle 2: Optimalisatie Gen Pen Gen Gen
Controle 3: Diepte 7 cm 7 cm 13 cm 5 cm
Controle 4: THI Aan Uit Aan Aan
Gegevens zijn niet van toepassing op deze transducer/modus.
Français
English Deutsch Español NederlandsItaliano Portugs
Akoestisch vermogen 105
Tabel 11: Transducermodel: rP19xp Bedieningsmodus: Kleur, CPD
Indexlabel M.I.
TIS TIB
TIC
Scan
Zonder scan
Zonder
scan
A
aprt
1 A
aprt
>1
Algemene maximale indexwaarde 1,5 1,6 - - - 3,8
Gekoppelde akoestische
parameter
p
r.3
(MPa) 2,15
W
0
(mW) 134,3 - - 174,1
min van [W
.3
(z
1
),
I
TA.3
(z
1
)]
(mW) -
z
1
(cm) -
Z
bp
(cm) -
Z
sp
(cm) -
z@PII
.3max
4,3
d
eq
(z
sp
) (cm) -
F
c
(MHz) 2,05 2,60 - - - 2,09
Dim. van A
aprt
X (cm) 1,34 - - - 0,63
Y (cm) 1,15 - - - 1,15
Overige informatie
PD (μsec) 1,662
PRF (Hz) 1526
p
r
@PII
max
(MPa) 2,91
d
eq
@Pll
max
(cm) -
Brandpuntlengte BPL
x
(cm)
4,56 - - 2,25
BPL
y
(cm)
9,00 - - 9,00
I
PA.3
@MI
max
(W/cm
2
)
355
Gegevens zijn niet van toepassing op deze transducer/modus.
106 Akoestisch vermogen
Bedrijfs-
bedienings-
omstandigheden
Controle 1: Onderzoekstype Long Verl Crd
Controle 2: Modus CVD CVD CVD
Controle 3: 2D-optimalisatie/
diepte
Gen/
13 cm
Gen/
5 cm
Pen/
5 cm
Controle 4: Sectorbreedte/THI N.v.t. N.v.t./uit Gem./
aan
Controle 5: Kleuroptimalisatie/
PRF
Laag/
273 Hz
Hoog/
2841 Hz
Hoog/
3571 Hz
Controle 6: Positie/grootte
kleurenvak
Opg/smal Bodem/
klein
Opg/
smal
Tabel 12: Transducermodel: rP19xp Bedieningsmodus: PW Doppler
Indexlabel M.I.
TIS TIB
TIC
Scan
Zonder scan
Zonder
scan
A
aprt
1 A
aprt
>1
Algemene maximale indexwaarde 1,5 - - 1,9 4,0 3,2
Gekoppelde akoestische
parameter
p
r.3
(MPa) 2,17
W
0
(mW) - - 192,5 211,8
min van [W
.3
(z
1
),
I
TA.3
(z
1
)]
(mW) 108,3
z
1
(cm) 1,9
Z
bp
(cm) 2,5
Z
sp
(cm) 5,10
z@PII
.3max
0,5
d
eq
(z
sp
) (cm) 0,60
F
c
(MHz) 2,08 - - 3,69 2,06 2,04
Dim. van A
aprt
X (cm) - - 1,92 1,92 1,92
Y (cm) - - 1,15 1,15 1,15
Gegevens zijn niet van toepassing op deze transducer/modus.
Tabel 11: Transducermodel: rP19xp Bedieningsmodus: Kleur, CPD
Indexlabel M.I.
TIS TIB
TIC
Scan
Zonder scan
Zonder
scan
A
aprt
1 A
aprt
>1
Gegevens zijn niet van toepassing op deze transducer/modus.
Français
English Deutsch Español NederlandsItaliano Portugs
Akoestisch vermogen 107
Overige informatie
PD (μsec) 1,141
PRF (Hz) 1562
p
r
@PII
max
(MPa) 2,24
d
eq
@Pll
max
(cm) 0,54
Brandpuntlengte BPL
x
(cm)
- - 11,51 11,51
BPL
y
(cm)
- - 9,00 9,00
I
PA.3
@MI
max
(W/cm
2
)
156
Bedrijfs-
bedienings-
omstandigheden
Controle 1: Onderzoekstype Abd Crd Abd Abd
Controle 2: Monstervolumegrootte 1 mm 7 mm 1 mm 1 mm
Controle 3: Monstervolumepositie Zone 0
(13 mm)
Zone 7
(115 mm)
Zone 6
(96 mm)
Zone 7
(115 mm)
Controle 4: PRF 1562 Hz 1008 Hz 1562 Hz 1562 Hz
Controle 5: TDI Uit Aan Uit Uit
Tabel 12: Transducermodel: rP19xp Bedieningsmodus: PW Doppler
Indexlabel M.I.
TIS TIB
TIC
Scan
Zonder scan
Zonder
scan
A
aprt
1 A
aprt
>1
Gegevens zijn niet van toepassing op deze transducer/modus.
108 Akoestisch vermogen
Tabel 13: Transducermodel: rP19xp Bedieningsmodus: CW Doppler
Indexlabel M.I.
TIS TIB
TIC
Scan
Zonder scan
Zonder
scan
A
aprt
1 A
aprt
>1
Algemene maximale indexwaarde (a) - 1,2 - 4,0 3,1
Gekoppelde akoestische
parameter
p
r.3
(MPa) #
W
0
(mW) - 130,6 134,7 125,7
min van [W
.3
(z
1
),
I
TA.3
(z
1
)]
(mW) -
z
1
(cm) -
Z
bp
(cm) -
Z
sp
(cm) 3,40
z@PII
.3max
#
d
eq
(z
sp
) (cm) 0,47
F
c
(MHz) # - 2,00 - 2,00 2,00
Dim. van A
aprt
X (cm) - 0,90 - 0,90 0,72
Y (cm) - 1,15 - 1,15 1,15
Overige informatie
PD (μsec) #
PRF (Hz) #
p
r
@PII
max
(MPa) #
d
eq
@Pll
max
(cm) 0,47
Brandpuntlengte BPL
x
(cm)
- 22,01 - 1,30
BPL
y
(cm)
- 9,00 - 9,00
I
PA.3
@MI
max
(W/cm
2
)
#
Bedrijfs-
bedienings-
omstandigheden
Controle 1: Onderzoekstype Crd Crd Crd
Controle 2: Monstervolumepositie Zone 11
(220 mm)
Zone 10
(189 mm)
Zone 0
(13 mm)
(a) Deze index is niet vereist voor deze bedieningsmodus; waarde is <1.
# Er zijn geen gegevens gerapporteerd voor deze bedieningstoestand, omdat de algemene maximale indexwaarde
niet is gerapporteerd voor de vermelde reden. (Raadpleeg lijn algemene maximale indexwaarde.)
Gegevens zijn niet van toepassing op deze transducer/modus.
Français
English Deutsch Español NederlandsItaliano Portugs
Akoestisch vermogen 109
Tabel 14: Transducermodel: rP19xp (orbitaal gebruik), Bedieningsmodus: 2D
Indexlabel M.I.
TIS TIB
TIC
Scan
Zonder scan
Zonder
scan
A
aprt
1 A
aprt
>1
Algemene maximale indexwaarde 0,17 0,026 - - - 0,057
Gekoppelde akoestische
parameter
p
r.3
(MPa) 0,26
W
0
(mW) 2,35 - - 3,88
min van [W
.3
(z
1
),
I
TA.3
(z
1
)]
(mW) -
z
1
(cm) -
Z
bp
(cm) -
Z
sp
(cm) -
z@PII
.3max
4,00
d
eq
(z
sp
) (cm) -
F
c
(MHz) 2,34 2,33 - - - 2,34
Dim. van A
aprt
X (cm) 1,92 - - - 1,92
Y (cm) 1,15 - - - 1,15
Overige informatie
PD (μsec) 0,59
PRF (Hz) 2317
p
r
@PII
max
(MPa) 0,45
d
eq
@Pll
max
(cm) -
Brandpuntlengte BPL
x
(cm)
16,77 - - 16,77
BPL
y
(cm)
9,00 - - 9,00
I
PA.3
@MI
max
(W/cm
2
)
3,41
Bedrijfs-
bedienings-
omstandigheden
Controle 1: Onderzoekstype Orb Orb Orb
Controle 2: Optimalisatie Gen Gen Gen
Controle 3: Diepte 31 cm 31 cm 31 cm
Controle 4: THI Uit Uit Uit
Gegevens zijn niet van toepassing op deze transducer/modus.
110 Akoestisch vermogen
Tabel 15: Transducermodel: rP19xp (orbitaal gebruik), Bedieningsmodus: M Mode
Indexlabel M.I.
TIS TIB
TIC
Scan
Zonder scan
Zonder
scan
A
aprt
1 A
aprt
>1
Algemene maximale indexwaarde 0,17 0,025 0,012 0,055
Gekoppelde akoestische
parameter
p
r.3
(MPa) 0,26
W
0
(mW) 1,848 - 0,84 3,68
min van [W
.3
(z
1
),
I
TA.3
(z
1
)]
(mW) 0,41
z
1
(cm) 2,80
Z
bp
(cm) 2,52
Z
sp
(cm) 3,8
z@PII
.3max
4,00
d
eq
(z
sp
) (cm) 0,85
F
c
(MHz) 2,34 2,37 - 2,37 2,34 2,37
Dim. van A
aprt
X (cm) 1,92 - 1,92 1,92 1,92
Y (cm) 1,15 - 1,15 1,15 1,15
Overige informatie
PD (μsec) 0,59
PRF (Hz) 1600
p
r
@PII
max
(MPa) 0,45
d
eq
@Pll
max
(cm) 0,58
Brandpuntlengte BPL
x
(cm)
14,0 - 14,0 14,0
BPL
y
(cm)
9,0 - 9,0 9,0
I
PA.3
@MI
max
(W/cm
2
)
3,41
Bedrijfs-
bedienings-
omstandigheden
Controle 1: Onderzoekstype Orb Orb Orb Orb
Controle 2: Optimalisatie Gen Gen Gen Gen
Controle 3: Diepte 31 cm 25 cm 31 cm 25 cm
Controle 4: THI Uit Uit Uit Uit
Gegevens zijn niet van toepassing op deze transducer/modus.
Français
English Deutsch Español NederlandsItaliano Portugs
Akoestisch vermogen 111
Tabel 16: Transducermodel: rP19xp (orbitaal gebruik), Bedieningsmodus: Kleur, CPD
Indexlabel M.I.
TIS TIB
TIC
Scan
Zonder scan
Zonder
scan
A
aprt
1 A
aprt
>1
Algemene maximale indexwaarde 0,20 0,055 - - - 0,12
Gekoppelde akoestische
parameter
p
r.3
(MPa) 0,28
W
0
(mW) 5,55 - - 5,77
min van [W
.3
(z
1
),
I
TA.3
(z
1
)]
(mW) -
z
1
(cm) -
Z
bp
(cm) -
Z
sp
(cm) -
z@PII
.3max
0,4
d
eq
(z
sp
) (cm) -
F
c
(MHz) 2,07 2,068 - - - 2,068
Dim. van A
aprt
X (cm) 0,96 - - - 0,96
Y (cm) 1,15 - - - 1,15
Overige informatie
PD (μsec) 1,55
PRF (Hz) 6301
p
r
@PII
max
(MPa) 0,29
d
eq
@Pll
max
(cm) -
Brandpuntlengte BPL
x
(cm)
1,3 - - 1,3
BPL
y
(cm)
9,0 - - 9,0
I
PA.3
@MI
max
(W/cm
2
)
2,58
Bedrijfs-
bedienings-
omstandigheden
Controle 1: Onderzoekstype Orb Orb Orb
Controle 2: Modus CVD CVD CVD
Controle 3: 2D-optimalisatie/
diepte
Gen/5 cm Gen/
5
cm
Gen/
5
cm
Controle 4: Kleuroptimalisatie/PRF Gem./
2778 Hz
Gem./
2778 Hz
Gem./
2778 Hz
Controle 5: Positie/grootte
kleurenvak
Standaard/
boven
Stan-
daard/
boven
Stan-
daard/
boven
Gegevens zijn niet van toepassing op deze transducer/modus.
112 Akoestisch vermogen
Tabel 17: Transducermodel: rP19xp (orbitaal gebruik), Bedieningsmodus: PW Doppler
Indexlabel M.I.
TIS TIB
TIC
Scan
Zonder scan
Zonder
scan
A
aprt
1 A
aprt
>1
Algemene maximale indexwaarde 0,19 - - 0,22 0,56 0,51
Gekoppelde akoestische
parameter
p
r.3
(MPa) 0,28
W
0
(mW) - - 33,8 34,4
min van [W
.3
(z
1
),
I
TA.3
(z
1
)]
(mW) 21,89
z
1
(cm) 3,00
Z
bp
(cm) 2,52
Z
sp
(cm) 3,8
z@PII
.3max
0,8
d
eq
(z
sp
) (cm) 0,79
F
c
(MHz) 2,11 - - 2,09 2,09 2,09
Dim. van A
aprt
X (cm) - - 1,92 1,92 1,92
Y (cm) - - 1,15 1,15 1,15
Overige informatie
PD (μsec) 3,67
PRF (Hz) 3906
p
r
@PII
max
(MPa) 0,29
d
eq
@Pll
max
(cm) 0,69
Brandpuntlengte BPL
x
(cm)
- - 22,0 27,3
BPL
y
(cm)
- - 9,0 9,0
I
PA.3
@MI
max
(W/cm
2
)
2,43
Bedrijfs-
bedienings-
omstandigheden
Controle 1: Onderzoekstype Orb Orb Orb Orb
Controle 2: Monstervolumegrootte 3 mm 9 mm 9 mm 7 mm
Controle 3: Monstervolumepositie Zone 1
(23 mm)
Zone 11
(220 mm)
Zone 11
(220 mm)
Zone 13
(273 mm)
Controle 4: PRF 3906 Hz 2604 Hz 2604 Hz 1953 Hz
Gegevens zijn niet van toepassing op deze transducer/modus.
Dansk Norsk Svenska Ελληνικά Русский rkçe
Indledning 113
Tillæg til brugervejledningen til SonoSite
X-Porte rP19xp-transducer
Indledning ................................................................................................................................................... 113
Dokumentkonventioner .................................................................................................................................................................... 113
Sådan får man hjælp .......................................................................................................................................................................... 114
Billedbehandlingstilstande ...................................................................................................................... 115
Rengøring og desinficering ...................................................................................................................... 116
Sikkerhed ................................................................................................................................................... 116
Kompatibelt tilbehør og eksternt udstyr .................................................................................................................................. 117
Akustisk udgangseffekt ............................................................................................................................ 117
Retningslinjer for reduktion af MI og TI .................................................................................................................................... 117
Visning af udgangseffekt .................................................................................................................................................................. 118
Tabeller over akustisk udgangseffekt ........................................................................................................................................ 119
Indledning
Dette tillæg til brugervejledningen indeholder oplysninger om fP19xp-transduceren, som er kompatibel med
SonoSite X-Porte-ultralydssystemet.
Dokumentkonventioner
Dokumentet følger disse konventioner:
Betegnelsen ADVARSEL angiver forholdsregler, der skal tages for at forhindre personskade eller død.
Betegnelsen Forsigtig angiver forholdsregler, der skal tages for at forhindre skade på produkterne.
Betegnelsen Bemærk leverer supplerende oplysninger.
Nummererede trin med tal eller bogstaver skal udføres i en bestemt rækkefølge.
Opstillinger med punkttegn er lister over oplysninger, hvor rækkefølgen er underordnet.
Der findes en beskrivelse af mærkningssymboler, der findes på produktet, under "Mærkningssymboler" i
brugervejledningen til ultralydssystemet.
114 Indledning
Sådan får man hjælp
FUJIFILM SonoSites tekniske serviceafdeling kan kontaktes på følgende måde:
Trykt i USA.
Telefon
(USA eller Canada)
+1-877-657-8118
Telefon
(uden for USA eller
Canada)
+1-425-951-1330, eller ring til den lokale repræsentant
Fax +1-425-951-6700
E-mail ffss-service@fujifilm.com
Web www.sonosite.com
Europæisk
serviceafdeling
Hovednummer: +31 20 751 2020
Engelsk support: +44 14 6234 1151
Fransk support: +33 1 8288 0702
Tysk support: +49 69 8088 4030
Italiensk support: +39 02 9475 3655
Spansk support: +34 91 123 8451
Asiatisk
serviceafdeling
+65 6380-5581
Dansk Norsk Svenska Ελληνικά Русский rkçe
Billedbehandlingstilstande 115
Billedbehandlingstilstande
Tabel 1: Tilgængelig undersøgelsestyper og billedbehandlingstyper
Transducer
Undersø-
gelsestype
Billeddannelsestype
2D
M Mode
Farve
a
PW-
Doppler
b
CW-
doppler
rP19xp Abdomen CVD, CPD
Hjerte CVD, Var
Lung CVD, CPD
Obstetrik CVD, CPD
Orbital CVD, CPD
Transkraniel CVD, CPD
a
Var = Farve-Doppler-varians, som kun er tilgængelig ved hjerteundersøgelsen. CPD =
Farveamplitude-Doppler, som er tilgængelig i alle undersøgelser, undtagen hjerteundersøgelsen.
CVD = Color Velocity Doppler (farvehastighedsdoppler).
b
Til hjerteundersøgelsestypen er PW TDI også tilgængelig.
Bemærk rP19xp-transduceren kan bruges med nålestyr. Yderligere oplysninger kan findes i
Using CIVCO Products with FUJIFILM SonoSite Systems (Brug af CIVCO-
produkter sammen med FUJIFILM SonoSite-systemet).
116 Rengøring og desinficering
Rengøring og desinficering
Sikkerhed
Tabel 2: Godkendte rengøringsmidler
Produkt Kompatibel transducer
Mindste vådkontakttid
a
SaniCloth AF3
b
rP19xp 3 minutter
PI-spray II rP19xp 10 minutter
a
Den komponent, der rengøres, skal forblive våd med desinfektionsmiddel i den mindste vådkontaktperiode, for at
opnå maksimal virkning.
b
Godkendt til brug som desinfektionsmiddel på mellemniveau til mycobakterier.
Se dokumentet om rengørings- og desinfektionsmidler på www.sonosite.com for at få en komplet liste over de
nyeste rengørings- og desinfektionsmidler.
Tabel 3: Godkendte højniveaukompatible desinfektionsmidler
Desinfektions-
middel
a
Kompatibel transducer Temperatur
Varighed af iblødlægning i
desinfektionsmiddel
Cidex rP19xp
25
o
C
45 minutter
Cidex OPA rP19xp
20
o
C
12 minutter
a
Se dokumentet om rengørings- og desinfektionsmidler på www.sonosite.com for at få en komplet liste over de
nyeste rengørings- og desinfektionsmidler.
ADVARSEL For at undgå skader hos patienten eller beskadigelse af udstyret må en rP19xp-
nålestyrsholder ikke anvendes på patienter med pacemakere eller medicinske
elektroniske implantater. Nålestyrsholderen til rP19xp indeholder en magnet,
der bruges til at sikre, at holderen er placeret korrekt i forhold til transduceren.
Det magnetiske felt kan have en skadelig virkning, når det er i nærheden af
pacemakeren eller det medicinske elektroniske implantat.
Dansk Norsk Svenska Ελληνικά Русский rkçe
Akustisk udgangseffekt 117
Kompatibelt tilbehør og eksternt udstyr
Akustisk udgangseffekt
Retningslinjer for reduktion af MI og TI
Tabel 4: Tilbehørsdele og perifere enheder
Beskrivelse Maksimal kabellængde
rP19xp transducer
a
1,8 m
a
For transducere måles den maksimale kabellængde mellem aflastningerne. Den angivne længde omfatter ikke ka-
bellængder på følgende lokaliteter: under aflastningerne, inde i transducernes indkapsling eller inde i transducerkon-
nektoren.
Tabel 5: Retningslinjer for reduktion af mekanisk indeks (MI)
Transducer Dybde
rP19xp
Nedsæt eller sænk parameterens indstilling for at reducere MI.
Hæv eller øg indstillingen af parameteren for at reducere MI.
118 Akustisk udgangseffekt
Visning af udgangseffekt
Tabel 6: Retningslinjer for reduktion af termisk indeks (TI)
Transducer
CPD-indstillinger
PW-ind-
stillinger
Boks-
bredde
Boks-
højde
Boks-
dybde
PRF Dybde
Optime-
ring
rP19xp
(PRF)
Nedsæt eller sænk parameterens indstilling for at reducere TI.
Hæv eller forøg parameterens indstilling for at reducere TI.
Tabel 7: TI eller MI 1,0
Transducer Indeks
2D/
M Mode
CPD/
Farve
PW-
doppler
CW-
doppler
rP19xp MI Ja Ja Ja Nej
TIC, TIB eller TIS Ja Ja Ja Ja
Tabel 8: Stigning i transducerens overfladetemperatur, udvendig brug (°C )
Test rP19xp
Stillestående luft 15,8
Simuleret anvendelse 8,8
Dansk Norsk Svenska Ελληνικά Русский rkçe
Akustisk udgangseffekt 119
Tabeller over akustisk udgangseffekt
Tabel 9: Transducermodel: rP19xp Driftstilstand: 2D
Indeksbetegnelse M.I.
TIS TIB
TIC
Scan
Non-scan
Non-scan
A
aprt
1 A
aprt
>1
Globalt maksimum, indeksværdi 1,5 1,2 2,9
Tilknyttet akustisk
parameter
p
r.3
(MPa) 1,95
W
0
(mW) 120,0 190,8
min af [W
.3
(z
1
),I
TA.3
(z
1
)] (mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm)
z@PII
.3max
2,6
d
eq
(z
sp
) (cm)
F
c
(MHz) 1,72 2,02 1,80
Dim af A
aprt
X (cm) 1,92 1,92
Y (cm) 1,15 1,15
Øvrige oplysninger
PD (μsek.) 1,227
PRF (Hz) 2.933
p
r
@PII
max
(MPa) 2,30
d
eq
@Pll
max
(cm)
Fokallængde FL
x
(cm) 3,42 3,42
FL
y
(cm) 9,00 9,00
I
PA.3
@MI
max
(W/cm
2
)
225
Drifts-
knap
Forhold
Kontrol 1: Undersøgelsestype Crd Abd Abd
Kontrol 2: Optimering Gen Pen Gen
Kontrol 3: Dybde 7 cm 5 cm 5 cm
Kontrol 4: THI Til Fra Til
Kontrol 5: Sektorbredde Fuld Ikke
rele
-
vant
Ikke
relevant
Der findes ingen data for denne transducer/billeddannelsestype.
120 Akustisk udgangseffekt
Tabel 10: Transducermodel: rP19xp Driftstilstand: M Mode
Indeksbetegnelse M.I.
TIS TIB
TIC
Scan
Non-scan
Non-scan
A
aprt
1 A
aprt
>1
Globalt maksimum, indeksværdi 1,5 1,1 0,9 3,0
Tilknyttet akustisk
parameter
p
r.3
(MPa) 1,95
W
0
(mW) 105 9,8 25,4 180,5
min af [W
.3
(z
1
),I
TA.3
(z
1
)] (mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm) 3,02
z@PII
.3max
2,6
d
eq
(z
sp
) (cm) 0,444
F
c
(MHz) 1,72 2,09 2,09 1,732 1,75
Dim af A
aprt
X (cm) 1,92 0,78 1,02 1,92
Y (cm) 1,15 1,15 1,15 1,15
Øvrige oplysninger
PD (μsek.) 1,227
PRF (Hz) 2.693
p
r
@PII
max
(MPa) 2,30
d
eq
@Pll
max
(cm) 0,427
Fokallængde FL
x
(cm) 4,56 4,56 2,25
FL
y
(cm) 9,00 9,00 9,00
I
PA.3
@MI
max
(W/cm
2
)
225
Drifts-
knap
Forhold
Kontrol 1: Undersøgelsestype Crd Abd Crd Abd
Kontrol 2: Optimering Gen Pen Gen Gen
Kontrol 3: Dybde 7 cm 7 cm 13 cm 5 cm
Kontrol 4: THI Til Fra Til Til
Der findes ingen data for denne transducer/billeddannelsestype.
Dansk Norsk Svenska Ελληνικά Русский rkçe
Akustisk udgangseffekt 121
Tabel 11: Transducermodel: rP19xp Driftstilstand: Farve/CPD
Indeksbetegnelse M.I.
TIS TIB
TIC
Scan
Non-scan
Non-scan
A
aprt
1 A
aprt
>1
Globalt maksimum, indeksværdi 1,5 1,6 3,8
Tilknyttet akustisk
parameter
p
r.3
(MPa) 2,15
W
0
(mW) 134,3 174,1
min af [W
.3
(z
1
),I
TA.3
(z
1
)] (mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm)
z@PII
.3max
4,3
d
eq
(z
sp
) (cm)
F
c
(MHz) 2,05 2,60 2,09
Dim af A
aprt
X (cm) 1,34 0,63
Y (cm) 1,15 1,15
Øvrige oplysninger
PD (μsek.) 1,662
PRF (Hz) 1.526
p
r
@PII
max
(MPa) 2,91
d
eq
@Pll
max
(cm)
Fokallængde FL
x
(cm) 4,56 2,25
FL
y
(cm) 9,00 9,00
I
PA.3
@MI
max
(W/cm
2
)
355
Der findes ingen data for denne transducer/billeddannelsestype.
122 Akustisk udgangseffekt
Drifts-
knap
Forhold
Kontrol 1: Undersøgelsestype Lung OB Crd
Kontrol 2: Type CVD CVD CVD
Kontrol 3: 2D-optimering/dybde Gen/
13 cm
Gen/
5 cm
Pen/
5 cm
Kontrol 4: Sektorbredde/THI Ikke
relevant
Ikke
relevant/
Fra
Med/Til
Kontrol 5: Farveoptimering/PRF Lav/
273 Hz
Høj/
2.841 Hz
Høj/
3.571
Hz
Kontrol 6: Position/størrelse af
farveboks
Def/smal Bund/
lille
Def/
smal
Tabel 11: Transducermodel: rP19xp Driftstilstand: Farve/CPD
Indeksbetegnelse M.I.
TIS TIB
TIC
Scan
Non-scan
Non-scan
A
aprt
1 A
aprt
>1
Der findes ingen data for denne transducer/billeddannelsestype.
Dansk Norsk Svenska Ελληνικά Русский rkçe
Akustisk udgangseffekt 123
Tabel 12: Transducermodel: rP19xp Driftstilstand: PW-doppler
Indeksbetegnelse M.I.
TIS TIB
TIC
Scan
Non-scan
Non-scan
A
aprt
1 A
aprt
>1
Globalt maksimum, indeksværdi 1,5 1,9 4,0 3,2
Tilknyttet akustisk
parameter
p
r.3
(MPa) 2,17
W
0
(mW) 192,5 211,8
min af [W
.3
(z
1
),I
TA.3
(z
1
)] (mW) 108,3
z
1
(cm) 1,9
Z
bp
(cm) 2,5
Z
sp
(cm) 5,10
z@PII
.3max
0,5
d
eq
(z
sp
) (cm) 0,60
F
c
(MHz) 2,08 3,69 2,06 2,04
Dim af A
aprt
X (cm) 1,92 1,92 1,92
Y (cm) 1,15 1,15 1,15
Øvrige oplysninger
PD (μsek.) 1,141
PRF (Hz) 1.562
p
r
@PII
max
(MPa) 2,24
d
eq
@Pll
max
(cm) 0,54
Fokallængde FL
x
(cm) 11,51 11,51
FL
y
(cm) 9,00 9,00
I
PA.3
@MI
max
(W/cm
2
)
156
Drifts-
knap
Forhold
Kontrol 1: Undersøgelsestype Abd Crd Abd Abd
Kontrol 2: Prøvevolumenstørrelse 1 mm 7 mm 1 mm 1 mm
Kontrol 3: Position af
prøvevolumen
Zone 0
(13 mm)
Zone 7
(115 mm)
Zone 6
(96 mm)
Zone 7
(115 mm)
Kontrol 4: PRF 1.562 Hz 1.008 Hz 1.562 Hz 1.562 Hz
Kontrol 5: TDI Fra Til Fra Fra
Der findes ingen data for denne transducer/billeddannelsestype.
124 Akustisk udgangseffekt
Tabel 13: Transducermodel: rP19xp Driftstilstand: CW-doppler
Indeksbetegnelse M.I.
TIS TIB
TIC
Scan
Non-scan
Non-scan
A
aprt
1 A
aprt
>1
Globalt maksimum, indeksværdi (a) 1,2 4,0 3,1
Tilknyttet akustisk
parameter
p
r.3
(MPa) #
W
0
(mW) 130,6 134,7 125,7
min af [W
.3
(z
1
),I
TA.3
(z
1
)] (mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm) 3,40
z@PII
.3max
#
d
eq
(z
sp
) (cm) 0,47
F
c
(MHz) # 2,00 2,00 2,00
Dim af A
aprt
X (cm) 0,90 0,90 0,72
Y (cm) 1,15 1,15 1,15
Øvrige oplysninger
PD (μsek.) #
PRF (Hz) #
p
r
@PII
max
(MPa) #
d
eq
@Pll
max
(cm) 0,47
Fokallængde FL
x
(cm) 22,01 1,30
FL
y
(cm) 9,00 9,00
I
PA.3
@MI
max
(W/cm
2
)
#
Drifts-
knap
Forhold
Kontrol 1: Undersøgelsestype Crd Crd Crd
Kontrol 2: Position af
prøvevolumen
Zone 11
(220 mm)
Zone 10
(189 mm)
Zone 0
(13 mm)
(a) Dette indeks er ikke påkrævet til denne billeddannelsestype. Værdien er <1.
# Der er ikke rapporteret data for dette driftsforhold, da indeksværdien for det globale maksimum på grund af den
angivne årsag ikke er anført. (Se linjen for globalt maksimum, indeksværdi).
Der findes ingen data for denne transducer/billeddannelsestype.
Dansk Norsk Svenska Ελληνικά Русский rkçe
Akustisk udgangseffekt 125
Tabel 14: Transducermodel: rP19xp (Ophtalmologisk brug) Driftstilstand: 2D
Indeksbetegnelse M.I.
TIS TIB
TIC
Scan
Non-scan
Non-scan
A
aprt
1 A
aprt
>1
Globalt maksimum, indeksværdi 0,17 0,026 0,057
Tilknyttet akustisk
parameter
p
r.3
(MPa) 0,26
W
0
(mW) 2,35 3,88
min af [W
.3
(z
1
),I
TA.3
(z
1
)] (mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm)
z@PII
.3max
4,00
d
eq
(z
sp
) (cm)
F
c
(MHz) 2,34 2,33 2,34
Dim af A
aprt
X (cm) 1,92 1,92
Y (cm) 1,15 1,15
Øvrige oplysninger
PD (μsek.) 0,59
PRF (Hz) 2.317
p
r
@PII
max
(MPa) 0,45
d
eq
@Pll
max
(cm)
Fokallængde FL
x
(cm) 16,77 16,77
FL
y
(cm) 9,00 9,00
I
PA.3
@MI
max
(W/cm
2
)
3,41
Drifts-
knap
Forhold
Kontrol 1: Undersøgelsestype Orb Orb Orb
Kontrol 2: Optimering Gen Gen Gen
Kontrol 3: dybde 31 cm 31 cm 31 cm
Kontrol 4: THI Fra Fra Fra
Der findes ingen data for denne transducer/billeddannelsestype.
126 Akustisk udgangseffekt
Tabel 15: Transducermodel: rP19xp (Ophtalmologisk brug) Driftstilstand: M Mode
Indeksbetegnelse M.I.
TIS TIB
TIC
Scan
Non-scan
Non-scan
A
aprt
1 A
aprt
>1
Globalt maksimum, indeksværdi 0,17 0,025 0,012 0,055
Tilknyttet akustisk
parameter
p
r.3
(MPa) 0,26
W
0
(mW) 1.848 0,84 3,68
min af [W
.3
(z
1
),I
TA.3
(z
1
)] (mW) 0,41
z
1
(cm) 2,80
Z
bp
(cm) 2,52
Z
sp
(cm) 3,8
z@PII
.3max
4,00
d
eq
(z
sp
) (cm) 0,85
F
c
(MHz) 2,34 2,37 2,37 2,34 2,37
Dim af A
aprt
X (cm) 1,92 1,92 1,92 1,92
Y (cm) 1,15 1,15 1,15 1,15
Øvrige oplysninger
PD (μsek.) 0,59
PRF (Hz) 1.600
p
r
@PII
max
(MPa) 0,45
d
eq
@Pll
max
(cm) 0,58
Fokallængde FL
x
(cm) 14,0 14,0 14,0
FL
y
(cm) 9,0 9,0 9,0
I
PA.3
@MI
max
(W/cm
2
)
3,41
Drifts-
knap
Forhold
Kontrol 1: Undersøgelsestype Orb Orb Orb Orb
Kontrol 2: Optimering Gen Gen Gen Gen
Kontrol 3: dybde 31 cm 25 cm 31 cm 25 cm
Kontrol 4: THI Fra Fra Fra Fra
Der findes ingen data for denne transducer/billeddannelsestype.
Dansk Norsk Svenska Ελληνικά Русский rkçe
Akustisk udgangseffekt 127
Tabel 16: Transducermodel: rP19xp (Ophtalmologisk brug) Driftstilstand: Farve/CPD
Indeksbetegnelse M.I.
TIS TIB
TIC
Scan
Non-scan
Non-scan
A
aprt
1 A
aprt
>1
Globalt maksimum, indeksværdi 0,20 0,055 0,12
Tilknyttet akustisk
parameter
p
r.3
(MPa) 0,28
W
0
(mW) 5,55 5,77
min af
[W
.3
(z
1
),I
TA.3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm)
z@PII
.3max
0,4
d
eq
(z
sp
) (cm)
F
c
(MHz) 2,07 2.068 2,068
Dim af A
aprt
X (cm) 0,96 0,96
Y (cm) 1,15 1,15
Øvrige oplysninger
PD (μsek.) 1,55
PRF (Hz) 6.301
p
r
@PII
max
(MPa) 0,29
d
eq
@Pll
max
(cm)
Fokallængde FL
x
(cm) 1,3 1,3
FL
y
(cm) 9,0 9,0
I
PA.3
@MI
max
(W/cm
2
)
2,58
Drifts-
knap
Forhold
Kontrol 1: Undersøgelsestype Orb Orb Orb
Kontrol 2: Type CVD CVD CVD
Kontrol 3: 2D-optimering/dybde Gen/5 cm Gen/
5
cm
Gen/
5
cm
Kontrol 4: Farveoptimering/PRF Med/
2.778 Hz
Med/
2.778
Hz
Med/
2.778
Hz
Kontrol 5: Position/størrelse af
farveboks
Standard/
Top
Stan-
dard/
Top
Stan-
dard/
Top
Der findes ingen data for denne transducer/billeddannelsestype.
128 Akustisk udgangseffekt
Tabel 17: Transducermodel: rP19xp (Ophtalmologisk brug) Driftstilstand: PW-doppler
Indeksbetegnelse M.I.
TIS TIB
TIC
Scan
Non-scan
Non-scan
A
aprt
1 A
aprt
>1
Globalt maksimum, indeksværdi 0,19 0,22 0,56 0,51
Tilknyttet akustisk
parameter
p
r.3
(MPa) 0,28
W
0
(mW) 33,8 34,4
min af [W
.3
(z
1
),I
TA.3
(z
1
)] (mW) 21,89
z
1
(cm) 3,00
Z
bp
(cm) 2,52
Z
sp
(cm) 3,8
z@PII
.3max
0,8
d
eq
(z
sp
) (cm) 0,79
F
c
(MHz) 2,11 2,09 2,09 2,09
Dim af A
aprt
X (cm) 1,92 1,92 1,92
Y (cm) 1,15 1,15 1,15
Øvrige oplysninger
PD (μsek.) 3,67
PRF (Hz) 3.906
p
r
@PII
max
(MPa) 0,29
d
eq
@Pll
max
(cm) 0,69
Fokallængde FL
x
(cm) 22,0 27,3
FL
y
(cm) 9,0 9,0
I
PA.3
@MI
max
(W/cm
2
)
2,43
Drifts-
knap
Forhold
Kontrol 1: Undersøgelsestype Orb Orb Orb Orb
Kontrol 2: Prøvevolumenstørrelse 3 mm 9 mm 9 mm 7 mm
Kontrol 3: Position af
prøvevolumen
Zone 1
(23 mm)
Zone 11
(220 mm)
Zone 11
(220 mm)
Zone 13
(273 mm)
Kontrol 4: PRF 3.906 Hz 2.604 Hz 2.604 Hz 1.953 Hz
Der findes ingen data for denne transducer/billeddannelsestype.
Dansk Norsk Svenska Ελληνικά Русский rkçe
Innledning 129
Tillegg til brukerveiledning for SonoSite X-Porte
rP19xp-transduser
Innledning ................................................................................................................................................... 129
Konvensjoner for dokumentet ....................................................................................................................................................... 129
Slik får du hjelp ...................................................................................................................................................................................... 130
Avbildningsmodi ........................................................................................................................................ 131
Rengjøring og desinfisering ..................................................................................................................... 132
Sikkerhet .................................................................................................................................................... 132
Kompatibelt tilbehør og eksterne enheter .............................................................................................................................. 133
Akustisk effekt ........................................................................................................................................... 133
Retningslinjer for å redusere MI og TI ....................................................................................................................................... 133
Utdatavisning .......................................................................................................................................................................................... 134
Tabeller over akustisk utgang ........................................................................................................................................................ 135
Innledning
Dette tillegget til brukerveiledningen gir informasjon om rP19xp-transduseren, som er kompatibel med
SonoSite X-Porte-ultralydsystemet.
Konvensjoner for dokumentet
Dokumentet følger disse konvensjonene:
En ADVARSEL beskriver forholdsregler som er nødvendige for å avverge personskade eller dødsfall.
Forsiktig beskriver de nødvendige forholdsreglene som må tas for å beskytte produktene.
Merk gir tilleggsinformasjon.
Trinn med tall og bokstaver må utføres i en bestemt rekkefølge.
Punktlister gir informasjon i listeformat, men innebærer ikke en bestemt rekkefølge.
Du finner en beskrivelse av symbolene som vises på produktet, under "Symboler" i brukerhåndboken for
ultralydsystemet.
130 Innledning
Slik får du hjelp
Hvis du ønsker teknisk støtte, kan du ta kontakt med FUJIFILM SonoSite på følgende måte:
Trykt i USA.
Telefon
(USA eller Canada)
+1-877-657-8118
Telefon
(utenfor USA eller
Canada)
+1-425-951-1330, eller ta kontakt med din lokale
representant
Faks +1-425-951-6700
E-post ffss-service@fujifilm.com
Nettsted www.sonosite.com
Servicesenter i Europa Hovednummer: +31 20 751 2020
Engelsk støtte: +44 14 6234 1151
Fransk støtte: +33 1 8288 0702
Tysk støtte: +49 69 8088 4030
Italiensk støtte: +39 02 9475 3655
Spansk støtte: +34 91 123 8451
Servicesenter i Asia +65 6380-5581
Dansk Norsk Svenska Ελληνικά Русский rkçe
Avbildningsmodi 131
Avbildningsmodi
Tabell 1: Tilgjengelige undersøkelsestyper og avbildningsmodi
Transduser
Undersø-
kelsestype
Avbildningsmodus
2D
M Mode
Farge
a
PW-
doppler
b
CW-
doppler
rP19xp Abdominal CVD, CPD
Kardiologisk CVD, Var
Lunge CVD, CPD
Obstetrikk CVD, CPD
Orbital CVD, CPD
Transkranial CVD, CPD
a
Var = fargedopplervarians, som kun er tilgjengelig for hjerteundersøkelse. CPD = fargeenergidoppler,
som er tilgjengelig i alle undersøkelser unntatt hjerteundersøkelse. CVD = fargehastighetsdoppler.
b
PW TDI er også tilgjengelig for hjerteundersøkelse.
Merk rP19xp-transduseren kan brukes med nålføring. Se Using CIVCO Products with
FUJIFILM SonoSite Systems (Bruke CIVCO-produkter med FUJIFILM SonoSite-
systemer).
132 Rengjøring og desinfisering
Rengjøring og desinfisering
Sikkerhet
Tabell 2: Godkjente rengjøringsmidler
Produkt Kompatibel transduser
Minste kontakttid
a
SaniCloth AF3
b
rP19xp 3 minutter
PI-Spray II rP19xp 10 minutter
a
Maksimal effekt oppnås hvis komponenten som skal rengjøres, er fuktet med desinfiseringsmiddel i en bestemt
tidsperiode.
b
Egnet for bruk som et desinfiseringsmiddel på mellomnivå for mykobakterier.
En mer fullstendig liste finnes i dokumentet om rengjørings- og desinfiseringsmidler på www.sonosite.com .
Tabell 3: Godkjente desinfiseringsmidler for høynivådesinfisering
Desinfiserings-
middel
a
Kompatibel transduser Temperatur
Varighet av bløtlegging i
desinfiseringsmiddel
Cidex rP19xp
25
o
C
45 minutter
Cidex OPA rP19xp
20
o
C
12 minutter
a
En mer fullstendig liste finnes i dokumentet om rengjørings- og desinfiseringsmidler på www.sonosite.com.
ADVARSEL For å unngå skade på utstyr eller pasient må ikke rP19xp-braketten for nålføring
brukes på pasienter med pacemakere eller medisinske elektroniske implantater.
Braketten for nålføring for rP19xp inneholder en magnet som brukes for å sikre
at braketten er plassert på transduseren i riktig retning. Magnetfeltet i
umiddelbar nærhet av pacemakeren eller det medisinske elektroniske
implantatet kan ha en negativ virkning.
Dansk Norsk Svenska Ελληνικά Русский rkçe
Akustisk effekt 133
Kompatibelt tilbehør og eksterne enheter
Akustisk effekt
Retningslinjer for å redusere MI og TI
Tabell 4: Tilbehør og eksterne enheter
Beskrivelse Maks. kabellengde
rP19xp-transduser
a
1,8 m
a
For transdusere måles maksimal kabellengde mellom strekkavlastningene. De angitte lengdene omfatter ikke kabel-
lengdene på følgende plasseringer: under strekkavlastningene, inne i transduserhuset eller inne i transduserkontak-
ten.
Tabell 5: Retningslinjer for å redusere mekanisk indeks (MI)
Transduser Dybde
rP19xp
Reduser eller nedjuster innstillingen for parameteren for å redusere MI.
Øk eller oppjuster innstillingen for parameteren for å redusere MI.
134 Akustisk effekt
Utdatavisning
Tabell 6: Retningslinjer for å redusere termisk indeks (TI)
Transduser
CPD-innstillinger
PW-inn-
stillinger
Boks-
bredde
Boks-
høyde
Boks-
dybde
PRF Dybde
Optima-
lisere
rP19xp
(PRF)
Reduser eller nedjuster innstillingen for parameteren for å redusere TI.
Øk eller oppjuster innstillingen for parameteren for å redusere TI.
Tabell 7: TI eller MI 1,0
Transduser Indeks
2D/
M Mode
CPD/
Farge
PW-
doppler
CW-
doppler
rP19xp MI Ja Ja Ja Nei
TIC, TIB eller TIS Ja Ja Ja Ja
Tabell 8: Transduserens overflatetemperaturøkning, ekstern bruk (°C )
Test rP19xp
Stille luft 15,8
Simulert bruk 8,8
Dansk Norsk Svenska Ελληνικά Русский rkçe
Akustisk effekt 135
Tabeller over akustisk utgang
Tabell 9: Transdusermodell: rP19xp Driftsmodus: 2D
Indeksmerke M.I.
TIS TIB
TIC
Skan-
ning
Ikke-skanning
Ikke-
skanning
A
aprt
1 A
aprt
>1
Global maksimal indeksverdi 1,5 1,2 2,9
Tilknyttet akustisk
parameter
p
r0,3
(MPa) 1,95
W
0
(mW) 120,0 190,8
min av
[W
0,3
(z
1
),I
TA0,3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm)
z@PII
0,3maks.
2,6
d
eq
(z
sp
) (cm)
F
c
(MHz) 1,72 2,02 1,80
Dim av A
aprt
X (cm) 1,92 1,92
Y (cm) 1,15 1,15
Annen informasjon
PD (μsek) 1,227
PRF (Hz) 2933
p
r
@PII
maks.
(MPa) 2,30
d
eq
@Pll
maks.
(cm)
Fokal lengde FL
x
(cm) 3,42 3,42
FL
y
(cm) 9,00 9,00
I
PA0,3
@MI
maks.
(W/cm
2
)
225
Drifts-
kontroll-
betingelser
Kontroll 1: undersøkelsestype Crd Abd Abd
Kontroll 2: optimalisering Gen Pen Gen
Kontroll 3: dybde 7 cm 5 cm 5 cm
Kontroll 4: THI Av
Kontroll 5: sektorbredde Full I/R I/R
Data gjelder ikke for denne transduseren/modusen.
136 Akustisk effekt
Tabell 10: Transdusermodell: rP19xp Driftsmodus: M Mode
Indeksmerke M.I.
TIS TIB
TIC
Skan-
ning
Ikke-skanning
Ikke-
skanning
A
aprt
1 A
aprt
>1
Global maksimal indeksverdi 1,5 1,1 0,9 3,0
Tilknyttet akustisk
parameter
p
r0,3
(MPa) 1,95
W
0
(mW) 105 9,8 25,4 180,5
min av
[W
0,3
(z
1
),I
TA0,3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm) 3,02
z@PII
0,3maks.
2,6
d
eq
(z
sp
) (cm) 0,444
F
c
(MHz) 1,72 2,09 2,09 1,732 1,75
Dim av A
aprt
X (cm) 1,92 0,78 1,02 1,92
Y (cm) 1,15 1,15 1,15 1,15
Annen informasjon
PD (μsek) 1,227
PRF (Hz) 2693
p
r
@PII
maks.
(MPa) 2,30
d
eq
@Pll
maks.
(cm) 0,427
Fokal lengde FL
x
(cm) 4,56 4,56 2,25
FL
y
(cm) 9,00 9,00 9,00
I
PA0,3
@MI
maks.
(W/cm
2
)
225
Drifts-
kontroll-
betingelser
Kontroll 1: undersøkelsestype Crd Abd Crd Abd
Kontroll 2: optimalisering Gen Pen Gen Gen
Kontroll 3: dybde 7 cm 7 cm 13 cm 5 cm
Kontroll 4: THI Av
Data gjelder ikke for denne transduseren/modusen.
Dansk Norsk Svenska Ελληνικά Русский rkçe
Akustisk effekt 137
Tabell 11: Transdusermodell: rP19xp Driftsmodus: Farge/CPD
Indeksmerke M.I.
TIS TIB
TIC
Skan-
ning
Ikke-skanning
Ikke-
skanning
A
aprt
1 A
aprt
>1
Global maksimal indeksverdi 1,5 1,6 3,8
Tilknyttet akustisk
parameter
p
r0,3
(MPa) 2,15
W
0
(mW) 134,3 174,1
min av
[W
0,3
(z
1
),I
TA0,3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm)
z@PII
0,3maks.
4,3
d
eq
(z
sp
) (cm)
F
c
(MHz) 2,05 2,60 2,09
Dim av A
aprt
X (cm) 1,34 0,63
Y (cm) 1,15 1,15
Annen informasjon
PD (μsek) 1,662
PRF (Hz) 1526
p
r
@PII
maks.
(MPa) 2,91
d
eq
@Pll
maks.
(cm)
Fokal lengde FL
x
(cm) 4,56 2,25
FL
y
(cm) 9,00 9,00
I
PA0,3
@MI
maks.
(W/cm
2
)
355
Drifts-
kontroll-
betingelser
Kontroll 1: undersøkelsestype Lunge OB Crd
Kontroll 2: modus CVD CVD CVD
Kontroll 3: 2D-optimalisering/
dybde
Gen/
13 cm
Gen/
5 cm
Pen/
5 cm
Kontroll 4: sektorbredde/THI I/R I/R/av Med/på
Kontroll 5: fargeoptimalisering/
PRF
Lav/
273 Hz
Høy /
2841 Hz
Høy /
3571 Hz
Kontroll 6: fargeboksposisjon/
størrelse
Def/smal Bunn/
liten
Def/
smal
Data gjelder ikke for denne transduseren/modusen.
138 Akustisk effekt
Tabell 12: Transdusermodell: rP19xp Driftsmodus: PW-doppler
Indeksmerke M.I.
TIS TIB
TIC
Skan-
ning
Ikke-skanning
Ikke-
skanning
A
aprt
1 A
aprt
>1
Global maksimal indeksverdi 1,5 1,9 4,0 3,2
Tilknyttet akustisk
parameter
p
r0,3
(MPa) 2,17
W
0
(mW) 192,5 211,8
min av
[W
0,3
(z
1
),I
TA0, 3
(z
1
)]
(mW) 108,3
z
1
(cm) 1,9
Z
bp
(cm) 2,5
Z
sp
(cm) 5,10
z@PII
0,3maks.
0,5
d
eq
(z
sp
) (cm) 0,60
F
c
(MHz) 2,08 3,69 2,06 2,04
Dim av A
aprt
X (cm) 1,92 1,92 1,92
Y (cm) 1,15 1,15 1,15
Annen informasjon
PD (μsek) 1,141
PRF (Hz) 1562
p
r
@PII
maks.
(MPa) 2,24
d
eq
@Pll
maks.
(cm) 0,54
Fokal lengde FL
x
(cm) 11,51 11,51
FL
y
(cm) 9,00 9,00
I
PA0, 3
@MI
maks.
(W/cm
2
)
156
Drifts-
kontroll-
betingelser
Kontroll 1: undersøkelsestype Abd Crd Abd Abd
Kontroll 2: prøvevolumstørrelse 1 mm 7 mm 1 mm 1 mm
Kontroll 3: posisjon for prøvevolum Sone 0
(13 mm)
Sone 7
(115 mm)
Sone 6
(96 mm)
Sone 7
(115 mm)
Kontroll 4: PRF 1562 Hz 1008 Hz 1562 Hz 1562 Hz
Kontroll 5: TDI Av Av Av
Data gjelder ikke for denne transduseren/modusen.
Dansk Norsk Svenska Ελληνικά Русский rkçe
Akustisk effekt 139
Tabell 13: Transdusermodell: rP19xp Driftsmodus: CW-doppler
Indeksmerke M.I.
TIS TIB
TIC
Skan-
ning
Ikke-skanning
Ikke-
skanning
A
aprt
1 A
aprt
>1
Global maksimal indeksverdi (a) 1,2 4,0 3,1
Tilknyttet akustisk
parameter
p
r0,3
(MPa) #
W
0
(mW) 130,6 134,7 125,7
min av
[W
0,3
(z
1
),I
TA0,3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm) 3,40
z@PII
0,3maks.
#
d
eq
(z
sp
) (cm) 0,47
F
c
(MHz) # 2,00 2,00 2,00
Dim av A
aprt
X (cm) 0,90 0,90 0,72
Y (cm) 1,15 1,15 1,15
Annen informasjon
PD (μsek) #
PRF (Hz) #
p
r
@PII
maks.
(MPa) #
d
eq
@Pll
maks.
(cm) 0,47
Fokal lengde FL
x
(cm) 22,01 1,30
FL
y
(cm) 9,00 9,00
I
PA0,3
@MI
maks.
(W/cm
2
)
#
Drifts-
kontroll-
betingelser
Kontroll 1: undersøkelsestype Crd Crd Crd
Kontroll 2: posisjon for prøvevolum Sone 11
(220 mm)
Sone 10
(189 mm)
Sone 0
(13 mm)
(a) Denne indeksen er ikke påkrevd for denne driftsmodusen. Verdien er <1.
# Det er ikke rapportert data for driftsbetingelsen, siden den globale maksimale indeksverdien ikke er rapportert av
nevnte grunn. (Se linjen Global maksimal indeksverdi.)
Data gjelder ikke for denne transduseren/modusen.
140 Akustisk effekt
Tabell 14: Transdusermodell: rP19xp (orbital bruk) Driftsmodus: 2D
Indeksmerke M.I.
TIS TIB
TIC
Skan-
ning
Ikke-skanning
Ikke-
skanning
A
aprt
1 A
aprt
>1
Global maksimal indeksverdi 0,17 0,026 0,057
Tilknyttet akustisk
parameter
p
r0,3
(MPa) 0,26
W
0
(mW) 2,35 3,88
min av
[W
0,3
(z
1
),I
TA0,3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm)
z@PII
0,3maks.
4,00
d
eq
(z
sp
) (cm)
F
c
(MHz) 2,34 2,33 2,34
Dim av A
aprt
X (cm) 1,92 1,92
Y (cm) 1,15 1,15
Annen informasjon
PD (μsek) 0,59
PRF (Hz) 2317
p
r
@PII
maks.
(MPa) 0,45
d
eq
@Pll
maks.
(cm)
Fokal lengde FL
x
(cm) 16,77 16,77
FL
y
(cm) 9,00 9,00
I
PA0,3
@MI
maks.
(W/cm
2
)
3,41
Drifts-
kontroll-
betingelser
Kontroll 1: undersøkelsestype Orb Orb Orb
Kontroll 2: optimalisering Gen Gen Gen
Kontroll 3: dybde 31 cm 31 cm 31 cm
Kontroll 4: THI Av Av Av
Data gjelder ikke for denne transduseren/modusen.
Dansk Norsk Svenska Ελληνικά Русский rkçe
Akustisk effekt 141
Tabell 15: Transdusermodell: rP19xp (orbital bruk) Driftsmodus: M Mode
Indeksmerke M.I.
TIS TIB
TIC
Skan-
ning
Ikke-skanning
Ikke-
skanning
A
aprt
1 A
aprt
>1
Global maksimal indeksverdi 0,17 0,025 0,012 0,055
Tilknyttet akustisk
parameter
p
r0,3
(MPa) 0,26
W
0
(mW) 1,848 0,84 3,68
min av
[W
0,3
(z
1
),I
TA0,3
(z
1
)]
(mW) 0,41
z
1
(cm) 2,80
Z
bp
(cm) 2,52
Z
sp
(cm) 3,8
z@PII
0,3maks.
4,00
d
eq
(z
sp
) (cm) 0,85
F
c
(MHz) 2,34 2,37 2,37 2,34 2,37
Dim av A
aprt
X (cm) 1,92 1,92 1,92 1,92
Y (cm) 1,15 1,15 1,15 1,15
Annen informasjon
PD (μsek) 0,59
PRF (Hz) 1600
p
r
@PII
maks.
(MPa) 0,45
d
eq
@Pll
maks.
(cm) 0,58
Fokal lengde FL
x
(cm) 14,0 14,0 14,0
FL
y
(cm) 9,0 9,0 9,0
I
PA0,3
@MI
maks.
(W/cm
2
)
3,41
Drifts-
kontroll-
betingelser
Kontroll 1: undersøkelsestype Orb Orb Orb Orb
Kontroll 2: optimalisering Gen Gen Gen Gen
Kontroll 3: dybde 31 cm 25 cm 31 cm 25 cm
Kontroll 4: THI Av Av Av Av
Data gjelder ikke for denne transduseren/modusen.
142 Akustisk effekt
Tabell 16: Transdusermodell: rP19xp (orbital bruk) Driftsmodus: Farge/CPD
Indeksmerke M.I.
TIS TIB
TIC
Skan-
ning
Ikke-skanning
Ikke-
skanning
A
aprt
1 A
aprt
>1
Global maksimal indeksverdi 0,20 0,055 0,12
Tilknyttet akustisk
parameter
p
r0,3
(MPa) 0,28
W
0
(mW) 5,55 5,77
min av
[W
0,3
(z
1
),I
TA0,3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm)
z@PII
0,3maks.
0,4
d
eq
(z
sp
) (cm)
F
c
(MHz) 2,07 2,068 2,068
Dim av A
aprt
X (cm) 0,96 0,96
Y (cm) 1,15 1,15
Annen informasjon
PD (μsek) 1,55
PRF (Hz) 6301
p
r
@PII
maks.
(MPa) 0,29
d
eq
@Pll
maks.
(cm)
Fokal lengde FL
x
(cm) 1,3 1,3
FL
y
(cm) 9,0 9,0
I
PA0,3
@MI
maks.
(W/cm
2
)
2,58
Drifts-
kontroll-
betingelser
Kontroll 1: undersøkelsestype Orb Orb Orb
Kontroll 2: modus CVD CVD CVD
Kontroll 3: 2D-optimalisering/
dybde
Gen/5 cm Gen/
5
cm
Gen/
5
cm
Kontroll 4: fargeoptimalisering/
PRF
Med/
2778 Hz
Med/
2778 Hz
Med/
2778 Hz
Kontroll 5: fargeboksposisjon/
størrelse
standard/
øverst
standard/
øverst
standard/
øverst
Data gjelder ikke for denne transduseren/modusen.
Dansk Norsk Svenska Ελληνικά Русский rkçe
Akustisk effekt 143
Tabell 17: Transdusermodell: rP19xp (orbital bruk) Driftsmodus: PW-doppler
Indeksmerke M.I.
TIS TIB
TIC
Skan
ning
Ikke-skanning
Ikke-
skanning
A
aprt
1 A
aprt
>1
Global maksimal indeksverdi 0,19 0,22 0,56 0,51
Tilknyttet akustisk
parameter
p
r0,3
(MPa) 0,28
W
0
(mW) 33,8 34,4
min av
[W
0,3
(z
1
),I
TA0,3
(z
1
)]
(mW) 21,89
z
1
(cm) 3,00
Z
bp
(cm) 2,52
Z
sp
(cm) 3,8
z@PII
0,3maks.
0,8
d
eq
(z
sp
) (cm) 0,79
F
c
(MHz) 2,11 2,09 2,09 2,09
Dim av A
aprt
X (cm) 1,92 1,92 1,92
Y (cm) 1,15 1,15 1,15
Annen informasjon
PD (μsek) 3,67
PRF (Hz) 3906
p
r
@PII
maks.
(MPa) 0,29
d
eq
@Pll
maks.
(cm) 0,69
Fokal lengde FL
x
(cm) 22,0 27,3
FL
y
(cm) 9,0 9,0
I
PA0,3
@MI
maks.
(W/cm
2
)
2,43
Drifts-
kontroll-
betingelser
Kontroll 1: undersøkelsestype Orb Orb Orb Orb
Kontroll 2: prøvevolumstørrelse 3 mm 9 mm 9 mm 7 mm
Kontroll 3: posisjon for
prøvevolum
Sone 1
(23 mm)
Sone 11
(220 mm)
Sone 11
(220 mm)
Sone 13
(273 mm)
Kontroll 4: PRF 3906 Hz 2604 Hz 2604 Hz 1953 Hz
Data gjelder ikke for denne transduseren/modusen.
144 Akustisk effekt
Dansk Norsk Svenska Ελληνικά Русский rkçe
Inledning 145
Tillägg till användarhandboken för SonoSite
X-Porte transduktor rP19xp
Inledning ..................................................................................................................................................... 145
Dokumentkonventioner .................................................................................................................................................................... 145
Få hjälp ....................................................................................................................................................................................................... 146
Bildåtergivningslägen ............................................................................................................................... 147
Rengöring och desinficering .................................................................................................................... 148
Säkerhet ..................................................................................................................................................... 148
Kompatibla tillbehör och kringutrustning ................................................................................................................................. 149
Akustisk uteffekt ....................................................................................................................................... 149
Riktlinjer för reduktion av MI och TI ........................................................................................................................................... 149
Visning av uteffekt ............................................................................................................................................................................... 150
Tabeller över akustisk uteffekt ....................................................................................................................................................... 151
Inledning
Detta tillägg till användarhandboken ger information om transduktorn rP19xp, som är kompatibel med
SonoSite X-Porte ultraljudssystem.
Dokumentkonventioner
Dokumentet följer dessa skrivsätt:
VARNING anger försiktighetsåtgärder som är nödvändiga för att förhindra personskador eller dödsfall.
Försiktighet anger försiktighetsåtgärder som är nödvändiga för att skydda produkterna.
Obs tillhandahåller kompletterande information.
Numrerade och bokstavsmarkerade steg måste utföras i en viss ordning.
Punktlistor visar information i form av en lista, men punkterna anger inte en viss ordningsföljd.
För en beskrivning av märkningssymboler som visas på produkten, se ”Märkningssymboler” i
ultraljudssystemets användarhandbok.
146 Inledning
hjälp
För teknisk support, kontakta FUJIFILM SonoSite på följande sätt:
Tryckt i USA.
Telefon
(USA eller Kanada)
+1-877-657-8118
Telefon
(utanför USA och
Kanada)
+1-425-951-1330 eller ring närmaste representant
Fax +1-425-951-6700
E-post ffss-service@fujifilm.com
Webbplats www.sonosite.com
Europeiskt
servicecenter
Växel: +31 20 751 2020
Support på engelska: +44 146 234 1151
Support på franska: +33 182 880 702
Support på tyska: +49 698 088 4030
Support på italienska: +39 029 475 3655
Support på spanska: +34 91 123 8451
Servicecenter i Asien +65 6380-5581
Dansk Norsk Svenska Ελληνικά Русский rkçe
Bildåtergivningslägen 147
Bildåtergivningslägen
Tabell 1: Tillgängliga undersökningstyper och bildåtergivningslägen
Transduk-
tor
Undersök-
ningstyp
Bildåtergivningsläge
2D
M Mode
Färgdopp-
ler
a
Pulsdopp-
ler (PW)
b
Kontinuer-
lig doppler
(CW)
rP19xp Buk CVD, CPD
Hjärta CVD, Var
Lung CVD, CPD
Obstetrik CVD, CPD
Orbital CVD, CPD
Transkraniell CVD, CPD
a
Var = Färgdopplervarians, som endast är tillgängligt i hjärtundersökningen. CPD = Energidoppler är
tillgängligt i alla undersökningar förutom hjärtundersökning. CVD = Färghastighetsdoppler
b
För hjärtundersökningar finns också PW TDI tillgänglig.
Obs! Transduktorn rP19xp har nålguidekapacitet. Mer information finns i Using CIVCO
Products with FUJIFILM SonoSite Systems (Använda CIVCO-produkter med
FUJIFILM SonoSite-system).
148 Rengöring och desinficering
Rengöring och desinficering
Säkerhet
Tabell 2: Godkända rengöringsmedel
Produkt Kompatibel transduktor
Minsta kontakttid för vätska
a
SaniCloth AF3
b
rP19xp 3 minuter
PI-Spray II rP19xp 10 minuter
a
För maximal effektivitet måste den komponent som rengörs vara våt av desinficeringsmedel under minst en viss
tid.
b
Kan användas som ett desinficeringsmedel på mellannivå för mykobakterier.
En komplett lista med de vanligaste rengörings- och desinficeringsmedlen finns i rengörings- och
desinficeringsdokumentet som är tillgängligt på www.sonosite.com.
Tabell 3: Godkända kompatibla högnivådesinficeringsmedel
Desinficerin
gsmedel
a
Kompatibel transduktor Temperatur
Blötläggningstid i
desinficeringsmedel
Cidex rP19xp
25
°C
45 minuter
Cidex OPA rP19xp
20
°C
12 minuter
a
En komplett lista med de vanligaste rengörings- och desinficeringsmedlen finns i rengörings- och
desinficeringsdokumentet som är tillgängligt på
www.sonosite.com.
VARNING Undvik skador på anordningen eller på patienter genom att inte använda rP19xp-
nålguidehållaren på patienter med pacemakers eller elektroniska medicinska
implantat. Nålguidehållaren för rP19xp är försedd med en magnet som används för
att säkerställa att hållaren är korrekt inriktad på transduktorn. Magnetfältet kan ha
ogynnsam inverkan om det placeras alldeles intill pacemakern eller elektroniska
medicinska implantat.
Dansk Norsk Svenska Ελληνικά Русский rkçe
Akustisk uteffekt 149
Kompatibla tillbehör och kringutrustning
Akustisk uteffekt
Riktlinjer för reduktion av MI och TI
Tabell 4: Tillbehör och kringutrustning
Beskrivning Maximal kabellängd
Transduktorn rP19xp
a
1,8 m
a
För transduktorer mäts den maximala kabellängden mellan dragavlastningarna. Den angivna längden inkluderar inte
kabellängden på följande platser: under dragavlastningarna, innanför transduktorhöljet eller innanför transduktoran-
slutningen.
Tabell 5: Riktlinjer för reduktion av mekaniskt index (MI)
Transduktor Djup
rP19xp
Minska eller sänk parameterinställningen för att reducera MI.
Höj eller öka parameterinställningen för att reducera MI.
150 Akustisk uteffekt
Visning av uteffekt
Tabell 6: Riktlinjer för reduktion av termiskt index (TI)
Transduk-
tor
Energidopplerinställningar
Pulsdopp-
lerinställ-
ningar
Rutans
bredd
Rutans
höjd
Rutans
djup
PRF Djup
Opti-
mera
rP19xp
(PRF)
Minska eller sänk parameterinställningen för att reducera TI.
Höj eller öka parameterinställningen för att reducera TI.
Tabell 7: TI eller MI ≥1,0
Transduktor Index
2D/
M Mode
CPD/
rg
PW-
doppler
CW-
doppler
rP19xp MI Ja Ja Ja Nej
TIC, TIB eller TIS Ja Ja Ja Ja
Tabell 8: Ökning av transduktorns yttemperatur, extern användning (°C )
Test rP19xp
Stillastående luft 15,8
Simulerad
användning
8,8
Dansk Norsk Svenska Ελληνικά Русский rkçe
Akustisk uteffekt 151
Tabeller över akustisk uteffekt
Tabell 9: Transduktormodell: rP19xp Driftsläge: 2D
Indexbeteckning MI
TIS TIB
TIC
Skan-
ning
Ej skanning
Ej
skanning
A
aprt
1 A
aprt
>1
Globalt maximalt indexvärde 1,5 1,2 2,9
Associerad akustisk
parameter
p
r.3
(MPa) 1,95
W
0
(mW) 120,0 190,8
min. av
[W
.3
(z
1
),I
TA.3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm)
z@PII
.3max
2,6
d
eq
(z
sp
) (cm)
F
c
(MHz) 1,72 2,02 1,80
Dim av A
aprt
X (cm) 1,92 1,92
Y (cm) 1,15 1,15
Övrig information
PD (μs) 1,227
PRF (Hz) 2 933
p
r
@PII
max
(MPa) 2,30
d
eq
@Pll
max
(cm)
Fokallängd FL
x
(cm) 3,42 3,42
FL
y
(cm) 9,00 9,00
I
PA.3
@MI
max
(W/cm
2
)
225
Drift-
reglage-
inställningar
Reglage 1: Undersökningstyp Crd Abd Abd
Reglage 2: Optimering Gen Pen Gen
Reglage 3: Djup 7 cm 5 cm 5 cm
Reglage 4: THI Av
Reglage 5: Sektorns bredd Full Sak-
nas
Saknas
Data ej tillämpliga för denna transduktor/detta bildåtergivningsläge.
152 Akustisk uteffekt
Tabell 10: Transduktormodell: rP19xp Driftsläge: M Mode
Indexbeteckning MI
TIS TIB
TIC
Skan-
ning
Ej skanning
Ej
skanning
A
aprt
1 A
aprt
>1
Globalt maximalt indexvärde 1,5 1,1 0,9 3,0
Associerad akustisk
parameter
p
r.3
(MPa) 1,95
W
0
(mW) 105 9,8 25,4 180,5
min. av
[W
.3
(z
1
),I
TA.3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm) 3,02
z@PII
.3max
2,6
d
eq
(z
sp
) (cm) 0,444
F
c
(MHz) 1,72 2,09 2,09 1,732 1,75
Dim av A
aprt
X (cm) 1,92 0,78 1,02 1,92
Y (cm) 1,15 1,15 1,15 1,15
Övrig information
PD (μs) 1,227
PRF (Hz) 2 693
p
r
@PII
max
(MPa) 2,30
d
eq
@Pll
max
(cm) 0,427
Fokallängd FL
x
(cm) 4,56 4,56 2,25
FL
y
(cm) 9,00 9,00 9,00
I
PA.3
@MI
max
(W/cm
2
)
225
Drift-
reglage-
inställningar
Reglage 1: Undersökningstyp Crd Abd Crd Abd
Reglage 2: Optimering Gen Pen Gen Gen
Reglage 3: Djup 7 cm 7 cm 13 cm 5 cm
Reglage 4: THI Av
Data ej tillämpliga för denna transduktor/detta bildåtergivningsläge.
Dansk Norsk Svenska Ελληνικά Русский rkçe
Akustisk uteffekt 153
Tabell 11: Transduktormodell: rP19xp Driftsläge: Färgdoppler/Energidoppler
Indexbeteckning MI
TIS TIB
TIC
Skan-
ning
Ej skanning
Ej
skanning
A
aprt
1 A
aprt
>1
Globalt maximalt indexvärde 1,5 1,6 3,8
Associerad akustisk
parameter
p
r.3
(MPa) 2,15
W
0
(mW) 134,3 174,1
min. av
[W
.3
(z
1
),I
TA.3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm)
z@PII
.3max
4,3
d
eq
(z
sp
) (cm)
F
c
(MHz) 2,05 2,60 2,09
Dim av A
aprt
X (cm) 1,34 0,63
Y (cm) 1,15 1,15
Övrig information
PD (μs) 1,662
PRF (Hz) 1 526
p
r
@PII
max
(MPa) 2,91
d
eq
@Pll
max
(cm)
Fokallängd FL
x
(cm) 4,56 2,25
FL
y
(cm) 9,00 9,00
I
PA.3
@MI
max
(W/cm
2
)
355
Drift-
reglage-
inställningar
Reglage 1: Undersökningstyp Lung OB Crd
Reglage 2: Läge CVD CVD CVD
Reglage 3: 2D-optimering/djup Gen/
13 cm
Gen/
5 cm
Pen/
5 cm
Reglage 4: Sektorns bredd/THI Saknas Saknas/
Av
Med/På
Reglage 5: Färgoptimering/PRF Låg
273 Hz
Hög/
2
841 Hz
Hög/
3
571 Hz
Reglage 6: Färgrutans läge/
storlek
Stand./
Smal
Under-
kant/liten
Stand./
Smal
Data ej tillämpliga för denna transduktor/detta bildåtergivningsläge.
154 Akustisk uteffekt
Tabell 12: Transduktormodell: rP19xp Driftsläge: Pulsdoppler
Indexbeteckning MI
TIS TIB
TIC
Skan-
ning
Ej skanning
Ej
skanning
A
aprt
1 A
aprt
>1
Globalt maximalt indexvärde 1,5 1,9 4,0 3,2
Associerad akustisk
parameter
p
r.3
(MPa) 2,17
W
0
(mW) 192,5 211,8
min. av
[W
.3
(z
1
),I
TA.3
(z
1
)]
(mW) 108,3
z
1
(cm) 1,9
Z
bp
(cm) 2,5
Z
sp
(cm) 5,10
z@PII
.3max
0,5
d
eq
(z
sp
) (cm) 0,60
F
c
(MHz) 2,08 3,69 2,06 2,04
Dim av A
aprt
X (cm) 1,92 1,92 1,92
Y (cm) 1,15 1,15 1,15
Övrig information
PD (μs) 1,141
PRF (Hz) 1 562
p
r
@PII
max
(MPa) 2,24
d
eq
@Pll
max
(cm) 0,54
Fokallängd FL
x
(cm) 11,51 11,51
FL
y
(cm) 9,00 9,00
I
PA.3
@MI
max
(W/cm
2
)
156
Drift-
reglage-
inställningar
Reglage 1: Undersökningstyp Abd Crd Abd Abd
Reglage 2: Provvolymens storlek 1 mm 7 mm 1 mm 1 mm
Reglage 3: Provvolymens position Zon 0
(13 mm)
Zon 7
(115 mm)
Zon 6
(96 mm)
Zon 7
(115 mm)
Reglage 4: PRF 1 562 Hz 1 008 Hz 1 562 Hz 1 562 Hz
Reglage 5: TDI Av Av Av
Data ej tillämpliga för denna transduktor/detta bildåtergivningsläge.
Dansk Norsk Svenska Ελληνικά Русский rkçe
Akustisk uteffekt 155
Tabell 13: Transduktormodell: rP19xp Driftsläge: Kontinuerlig doppler
Indexbeteckning MI
TIS TIB
TIC
Skan-
ning
Ej skanning
Ej
skanning
A
aprt
1 A
aprt
>1
Globalt maximalt indexvärde (a) 1,2 4,0 3,1
Associerad akustisk
parameter
p
r.3
(MPa) #
W
0
(mW) 130,6 134,7 125,7
min. av
[W
.3
(z
1
),I
TA.3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm) 3,40
z@PII
.3max
#
d
eq
(z
sp
) (cm) 0,47
F
c
(MHz) # 2,00 2,00 2,00
Dim av A
aprt
X (cm) 0,90 0,90 0,72
Y (cm) 1,15 1,15 1,15
Övrig information
PD (μs) #
PRF (Hz) #
p
r
@PII
max
(MPa) #
d
eq
@Pll
max
(cm) 0,47
Fokallängd FL
x
(cm) 22,01 1,30
FL
y
(cm) 9,00 9,00
I
PA.3
@MI
max
(W/cm
2
)
#
Drift-
reglage-
inställningar
Reglage 1: Undersökningstyp Crd Crd Crd
Reglage 2: Provvolymens position Zon 11
(220 mm)
Zon 10
(189 mm)
Zon 0
(13 mm)
(a) Detta index krävs inte för detta driftsläge, värdet är <1.
# Inga data rapporteras för detta driftförhållande eftersom det globala maximala indexvärdet inte rapporteras, av
angiven orsak. (Referensrad för globalt maximalt indexvärde.)
Data ej tillämpliga för denna transduktor/detta bildåtergivningsläge.
156 Akustisk uteffekt
Tabell 14: Transduktormodell: rP19xp (orbital användning) Driftsläge: 2D
Indexbeteckning MI
TIS TIB
TIC
Skan-
ning
Ej skanning
Ej
skanning
A
aprt
1 A
aprt
>1
Globalt maximalt indexvärde 0,17 0,026 0,057
Associerad akustisk
parameter
p
r.3
(MPa) 0,26
W
0
(mW) 2,35 3,88
min. av
[W
.3
(z
1
),I
TA.3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm)
z@PII
.3max
4,00
d
eq
(z
sp
) (cm)
F
c
(MHz) 2,34 2,33 2,34
Dim av A
aprt
X (cm) 1,92 1,92
Y (cm) 1,15 1,15
Övrig information
PD (μs) 0,59
PRF (Hz) 2 317
p
r
@PII
max
(MPa) 0,45
d
eq
@Pll
max
(cm)
Fokallängd FL
x
(cm) 16,77 16,77
FL
y
(cm) 9,00 9,00
I
PA.3
@MI
max
(W/cm
2
)
3,41
Drift-
reglage-
inställningar
Reglage 1: Undersökningstyp Orb Orb Orb
Reglage 2: Optimering Gen Gen Gen
Reglage 3: Djup 31 cm 31 cm 31 cm
Reglage 4: THI Av Av Av
Data ej tillämpliga för denna transduktor/detta bildåtergivningsläge.
Dansk Norsk Svenska Ελληνικά Русский rkçe
Akustisk uteffekt 157
Tabell 15: Transduktormodell: rP19xp (orbital användning) Driftsläge: M Mode
Indexbeteckning MI
TIS TIB
TIC
Skan-
ning
Ej skanning
Ej
skanning
A
aprt
1 A
aprt
>1
Globalt maximalt indexvärde 0,17 0,025 0,012 0,055
Associerad akustisk
parameter
p
r.3
(MPa) 0,26
W
0
(mW) 1,848 0,84 3,68
min. av
[W
.3
(z
1
),I
TA.3
(z
1
)]
(mW) 0,41
z
1
(cm) 2,80
Z
bp
(cm) 2,52
Z
sp
(cm) 3,8
z@PII
.3max
4,00
d
eq
(z
sp
) (cm) 0,85
F
c
(MHz) 2,34 2,37 2,37 2,34 2,37
Dim av A
aprt
X (cm) 1,92 1,92 1,92 1,92
Y (cm) 1,15 1,15 1,15 1,15
Övrig information
PD (μs) 0,59
PRF (Hz) 1 600
p
r
@PII
max
(MPa) 0,45
d
eq
@Pll
max
(cm) 0,58
Fokallängd FL
x
(cm) 14,0 14,0 14,0
FL
y
(cm) 9,0 9,0 9,0
I
PA.3
@MI
max
(W/cm
2
)
3,41
Drift-
reglage-
inställningar
Reglage 1: Undersökningstyp Orb Orb Orb Orb
Reglage 2: Optimering Gen Gen Gen Gen
Reglage 3: Djup 31 cm 25 cm 31 cm 25 cm
Reglage 4: THI Av Av Av Av
Data ej tillämpliga för denna transduktor/detta bildåtergivningsläge.
158 Akustisk uteffekt
Tabell 16: Transduktormodell: rP19xp (orbital användning) Driftsläge: Färgdoppler/Energidoppler
Indexbeteckning MI
TIS TIB
TIC
Skanning
Ej skanning
Ej
skanning
A
aprt
1 A
aprt
>1
Globalt maximalt indexvärde 0,20 0,055 0,12
Associerad akustisk
parameter
p
r.3
(MPa) 0,28
W
0
(mW) 5,55 5,77
min. av
[W
.3
(z
1
),I
TA.3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm)
z@PII
.3max
0,4
d
eq
(z
sp
) (cm)
F
c
(MHz) 2,07 2,068 2,068
Dim av A
aprt
X (cm) 0,96 0,96
Y (cm) 1,15 1,15
Övrig information
PD (μs) 1,55
PRF (Hz) 6 301
p
r
@PII
max
(MPa) 0,29
d
eq
@Pll
max
(cm)
Fokallängd FL
x
(cm) 1,3 1,3
FL
y
(cm) 9,0 9,0
I
PA.3
@MI
max
(W/cm
2
)
2,58
Drift-
reglage-
inställningar
Reglage 1: Undersökningstyp Orb Orb Orb
Reglage 2: Läge CVD CVD CVD
Reglage 3: 2D-optimering/djup Gen/5 cm Gen/5 cm Gen/
5
cm
Reglage 4: Färgoptimering/PRF Med/
2778 Hz
Med/
2
778 Hz
Med/
2
778 Hz
Reglage 5: Färgrutans läge/storlek Standard/
Överst
Standard/
Överst
Standard/
Överst
Data ej tillämpliga för denna transduktor/detta bildåtergivningsläge.
Dansk Norsk Svenska Ελληνικά Русский rkçe
Akustisk uteffekt 159
Tabell 17: Transduktormodell: rP19xp (orbital användning) Driftsläge: Pulsdoppler
Indexbeteckning MI
TIS TIB
TIC
Skan-
ning
Ej skanning
Ej
skanning
A
aprt
1 A
aprt
>1
Globalt maximalt indexvärde 0,19 0,22 0,56 0,51
Associerad akustisk
parameter
p
r.3
(MPa) 0,28
W
0
(mW) 33,8 34,4
min. av
[W
.3
(z
1
),I
TA.3
(z
1
)]
(mW) 21,89
z
1
(cm) 3,00
Z
bp
(cm) 2,52
Z
sp
(cm) 3,8
z@PII
.3max
0,8
d
eq
(z
sp
) (cm) 0,79
F
c
(MHz) 2,11 2,09 2,09 2,09
Dim av A
aprt
X (cm) 1,92 1,92 1,92
Y (cm) 1,15 1,15 1,15
Övrig information
PD (μs) 3,67
PRF (Hz) 3 906
p
r
@PII
max
(MPa) 0,29
d
eq
@Pll
max
(cm) 0,69
Fokallängd FL
x
(cm) 22,0 27,3
FL
y
(cm) 9,0 9,0
I
PA.3
@MI
max
(W/cm
2
)
2,43
Drift-
reglage-
inställningar
Reglage 1: Undersökningstyp Orb Orb Orb Orb
Reglage 2: Provvolymens storlek 3 mm 9 mm 9 mm 7 mm
Reglage 3: Provvolymens position Zon 1
(23 mm)
Zon 11
(220 mm)
Zon 11
(220 mm)
Zon 13
(273 mm)
Reglage 4: PRF 3 906 Hz 2 604 Hz 2 604 Hz 1 953 Hz
Data ej tillämpliga för denna transduktor/detta bildåtergivningsläge.
160 Akustisk uteffekt
Dansk Norsk Svenska Ελληνικά Русский rkçe
Εισαγωγή 161
Συμπλήρωμα στον οδηγό χρήσης του
Μορφοτροπέα SonoSite X-Porte rP19xp
Εισαγωγή ..................................................................................................................................................... 161
Συμβάσεις εγγράφου ................................................................................................................................................................. 161
Λήψη βοήθειας ............................................................................................................................................................................ 162
Τρόποι λειτουργίας απεικόνισης ............................................................................................................... 163
Καθαρισμός και απολύμανση .................................................................................................................... 164
Ασφάλεια ..................................................................................................................................................... 164
Συμβατά βοηθητικά εξαρτήματα και περιφερειακές συσκευές ................................................................................ 165
Ακουστική έξοδος ...................................................................................................................................... 165
Κατευθυντήριες οδηγίες για τη μείωση των δεικτών MI και TI ................................................................................... 165
Προβολή εξόδου ......................................................................................................................................................................... 166
Πίνακες ακουστικής εξόδου ................................................................................................................................................... 167
Εισαγωγή
Αυτό το συμπλήρωμα στον οδηγό χρήσης παρέχει πληροφορίες για το μορφοτροπέα rP19xp, που είναι
συμβατός με το σύστημα υπερήχων SonoSite X-Porte.
Συμβάσεις εγγράφου
Στο έγγραφο χρησιμοποιούνται οι παρακάτω συμβάσεις:
Η ΠΡΟΕΙΔΟΠΟΙΗΣΗ περιγράφει προφυλάξεις απαραίτητες για την αποτροπή τραυματισμού ή θανάτου.
Η Προσοχή περιγράφει προφυλάξεις απαραίτητες για την προστασία των προϊόντων.
Η Σημείωση παρέχει συμπληρωματικές πληροφορίες.
Τα αριθμημένα βήματα (με αριθμούς και γράμματα) πρέπει να εκτελούνται με συγκεκριμένη σειρά.
Οι λίστες με κουκκίδες παρέχουν πληροφορίες σε μορφή λίστας, αλλά δεν δηλώνουν αλληλουχία βημάτων.
Για μια περιγραφή των συμβόλων επισήμανσης που εμφανίζονται επάνω στο προϊόν, ανατρέξτε στην ενότητα
«Σύμβολα επισήμανσης» του οδηγού χρήσης του συστήματος υπερήχων.
162 Εισαγωγή
Λήψη βοήθειας
Για τεχνική υποστήριξη, επικοινωνήστε με τη FUJIFILM SonoSite στα εξής στοιχεία:
Εκτυπώθηκε στις Η.Π.Α.
Αρ. τηλεφώνου
(Η.Π.Α. ή Καναδάς)
+1-877-657-8118
Αρ. τηλεφώνου
(εκτός Η.Π.Α. ή Καναδά)
+1-425-951-1330. Μπορείτε επίσης να καλέσετε τον
αντιπρόσωπο της περιοχής σας
Φαξ +1-425-951-6700
Email ffss-ser[email protected]
Ιστότοπος www.sonosite.com
Κέντρο σέρβις στην
Ευρώπη
Κύριο: +31 20 751 2020
Υποστήριξη στα αγγλικά: +44 14 6234 1151
Υποστήριξη στα γαλλικά: +33 1 8288 0702
Υποστήριξη στα γερμανικά: +49 69 8088 4030
Υποστήριξη στα ιταλικά: +39 02 9475 3655
Υποστήριξη στα ισπανικά: +34 91 123 8451
Κέντρο σέρβις στην
Ασία
+65 6380-5581
Dansk Norsk Svenska Ελληνικά Русский rkçe
Τρόποι λειτουργίας απεικόνισης 163
Τρόποι λειτουργίας απεικόνισης
Πίνακας 1: Διαθέσιμοι τύποι εξέτασης και τρόποι λειτουργίας απεικόνισης
Μορφοτρο-
πέας
Τύπος
εξέτασης
Τρόπος λειτουργίας απεικόνισης
2D
M Mode
Έγχρωμη
α
PW
Doppler
β
CW Doppler
rP19xp Κοιλιακή χώρα CVD, CPD
Καρδιολογική CVD, Var
Πνεύμονας CVD, CPD
Μαιευτική CVD, CPD
Κογχική CVD, CPD
Διακρανιακή CVD, CPD
α
Var = Διακύμανση στροβιλώδους ροής έγχρωμου Doppler, η οποία είναι διαθέσιμη μόνο για
καρδιολογικές εξετάσεις. CPD = Έγχρωμο Doppler ισχύος, το οποίο είναι διαθέσιμο σε όλες τις εξετάσεις,
εκτός από τον τύπο καρδιολογικής εξέτασης. CVD = Έγχρωμο Doppler ταχύτητας.
β
Για τον τύπο της καρδιολογικής εξέτασης, διατίθεται επίσης PW TDI.
Σημείωση Ο μορφοτροπέας rP19xP διαθέτει τη δυνατότητα χρήσης οδηγού βελόνας. Για
περισσότερες πληροφορίες, ανατρέξτε στο Using CIVCO Products with FUJIFILM
SonoSite Systems (Χρήση προϊόντων CIVCO με συστήματα FUJIFILM SonoSite).
164 Καθαρισμός και απολύμανση
Καθαρισμός και απολύμανση
Ασφάλεια
Πίνακας 2: Εγκεκριμένα καθαριστικά
Προϊόν Συμβατός μορφοτροπέας
Ελάχιστος χρόνος επαφής
διαβροχής
α
SaniCloth AF3
β
rP19xp 3 λεπτά
PI-Spray II rP19xp 10 λεπτά
α
Για μέγιστη αποτελεσματικότητα, το διαμέρισμα που καθαρίζεται πρέπει να παραμένει διαβρεγμένο με το
απολυμαντικό για κάποιο ελάχιστο χρονικό διάστημα.
β
Εγκεκριμένο για χρήση ως απολυμαντικό μεσαίου επιπέδου για μυκοβακτηρίδια.
Για την πλήρη και ενημερωμένη λίστα προϊόντων καθαρισμού και απολύμανσης, ανατρέξτε στο έγγραφο για τα
καθαριστικά και τα απολυμαντικά που είναι διαθέσιμο στη διαδικτυακή τοποθεσία www.sonosite.com.
Πίνακας 3: Εγκεκριμένα απολυμαντικά υψηλού επιπέδου
Απολυμαντικό
α
Συμβατός μορφοτροπέας Θερμοκρασία
Διάρκεια εμβάπτισης στο
απολυμαντικό
Cidex rP19xp
25
o
C
45 λεπτά
Cidex OPA rP19xp
20
o
C
12 λεπτά
α
Για την πλήρη και ενημερωμένη λίστα προϊόντων καθαρισμού και απολύμανσης, ανατρέξτε στο έγγραφο για τα
καθαριστικά και τα απολυμαντικά που είναι διαθέσιμο στη διαδικτυακή τοποθεσία www.sonosite.com.
ΠΡΟΕΙΔΟΠΟΙΗΣΗ Για την αποφυγή πρόκλησης ζημιάς στη συσκευή ή τραυματισμού του
ασθενούς, μη χρησιμοποιείτε το στήριγμα οδηγού βελόνας rP19xp σε
ασθενείς με βηματοδότες ή ιατρικά ηλεκτρονικά εμφυτεύματα. Το
στήριγμα του οδηγού βελόνας για τον rP19xp περιέχει ένα μαγνήτη που
χρησιμοποιείται για τη διασφάλιση του σωστού προσανατολισμού του
στηρίγματος επάνω στον μορφοτροπέα. Εάν το μαγνητικό πεδίο βρεθεί
πολύ κοντά στον βηματοδότη ή σε ιατρικό ηλεκτρονικό εμφύτευμα,
ενδέχεται να προκαλέσει ανεπιθύμητες ενέργειες.
Dansk Norsk Svenska Ελληνικά Русский rkçe
Ακουστική έξοδος 165
Συμβατά βοηθητικά εξαρτήματα και περιφερειακές συσκευές
Ακουστική έξοδος
Κατευθυντήριες οδηγίες για τη μείωση των δεικτών MI και TI
Πίνακας 4: Βοηθητικά εξαρτήματα και περιφερειακές συσκευές
Περιγραφή Μέγιστο μήκος καλωδίου
Μορφοτροπέας rP19xp
α
1,8 m
α
Για τους μορφοτροπείς, το μέγιστο μήκος καλωδίου καταμετράται μεταξύ των διατάξεων ανακούφισης τάσης. Στα
αναφερόμενα μήκη δεν συμπεριλαμβάνονται τα μήκη του καλωδίου στις ακόλουθες θέσεις: κάτω από τις διατάξεις
ανακούφισης τάσης, στο εσωτερικό του περιβλήματος του μορφοτροπέα και στο εσωτερικό του συνδέσμου του μορ
-
φοτροπέα.
Πίνακας 5: Κατευθυντήριες οδηγίες για τη μείωση του μηχανικού δείκτη (ΜΙ)
Μορφοτροπέας Βάθος
rP19xp
Μείωση ή χαμηλότερη ρύθμιση της παραμέτρου για μείωση του δείκτη MI.
Αύξηση ή υψηλότερη ρύθμιση της παραμέτρου για τη μείωση του δείκτη MI.
166 Ακουστική έξοδος
Προβολή εξόδου
Πίνακας 6: Κατευθυντήριες οδηγίες για τη μείωση του θερμικού δείκτη (ΤΙ)
Μορφο-
τροπέας
Ρυθμίσεις CPD
Ρυθμίσεις
PW
(παλμικού
κύματος)
Πλάτος
πλαισίου
Ύψος
πλαισίου
Βάθος
πλαισίου
PRF Βάθος
Βελτι-
στοποί-
ηση
rP19xp
(PRF)
Μείωση ή χαμηλότερη ρύθμιση της παραμέτρου για μείωση του δείκτη TI.
Αύξηση ή υψηλότερη ρύθμιση της παραμέτρου για μείωση του δείκτη TI.
Πίνακας 7: TI ή MI 1,0
Μορφοτροπέας Δείκτης
2D/
M Mode
CPD/
Color
(Έγχρωμη
απεικόνιση)
PW Doppler CW Doppler
rP19xp MI Ναι Ναι Ναι Όχι
TIC, TIB ή TIS Ναι Ναι Ναι Ναι
Πίνακας 8: Αύξηση θερμοκρασίας επιφάνειας μορφοτροπέα, εξωτερική χρήση (°C )
Δοκιμή rP19xp
Μη βεβιασμένη
κίνηση αέρα
15,8
Προσομοιωμένη
χρήση
8,8
Dansk Norsk Svenska Ελληνικά Русский rkçe
Ακουστική έξοδος 167
Πίνακες ακουστικής εξόδου
Πίνακας 9: Μοντέλο μορφοτροπέα: rP19xp Τρόπος λειτουργίας: 2D
Ετικέτα δείκτη M.I.
TIS TIB
TIC
Σάρωση
Χωρίς σάρωση
Χωρίς
σάρωση
A
aprt
1 A
aprt
>1
Καθολική μέγιστη τιμή δείκτη 1,5 1,2 2,9
Σχετιζόμενη ακουστική
παράμετρος
p
r.3
(MPa) 1,95
W
0
(mW) 120,0 190,8
ελάχιστο των [W
.3
(z
1
),
I
TA.3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm)
z@PII
.3max
2,6
d
eq
(z
sp
) (cm)
F
c
(MHz) 1,72 2,02 1,80
Διαστ. του A
aprt
X (cm) 1,92 1,92
Y (cm) 1,15 1,15
Άλλες πληροφορίες
PD (μsec) 1,227
PRF (Hz) 2933
p
r
@PII
max
(MPa) 2,30
d
eq
@Pll
max
(cm)
Εστιακό μήκος FL
x
(cm) 3,42 3,42
FL
y
(cm) 9,00 9,00
I
PA.3
@MI
max
(W/cm
2
)
225
Συνθήκες
ελέγχου
λειτουργίας
Έλεγχος 1: Τύπος εξέτασης Καρδ. Κοιλ. Κοιλ.
Έλεγχος 2: Βελτιστοποίηση Γενική Διείσδ. Γενική
Έλεγχος 3: Βάθος 7 cm 5 cm 5 cm
Έλεγχος 4: THI Ενεργ. Απενεργ. Ενεργ.
Έλεγχος 5: Πλάτος τομέα Πλήρες Δ/Ι Δ/Ι
Τα δεδομένα δεν ισχύουν για αυτόν τον μορφοτροπέα/τρόπο λειτουργίας.
168 Ακουστική έξοδος
Πίνακας 10: Μοντέλο μορφοτροπέα: rP19xp Τρόπος λειτουργίας: M Mode
Ετικέτα δείκτη M.I.
TIS TIB
TIC
Σάρωση
Χωρίς σάρωση
Χωρίς
σάρωση
A
aprt
1 A
aprt
>1
Καθολική μέγιστη τιμή δείκτη 1,5 1,1 0,9 3,0
Σχετιζόμενη ακουστική
παράμετρος
p
r.3
(MPa) 1,95
W
0
(mW) 105 9,8 25,4 180,5
ελάχιστο των [W
.3
(z
1
),
I
TA.3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm) 3,02
z@PII
.3max
2,6
d
eq
(z
sp
) (cm) 0,444
F
c
(MHz) 1,72 2,09 2,09 1,732 1,75
Διαστ. του A
aprt
X (cm) 1,92 0,78 1,02 1,92
Y (cm) 1,15 1,15 1,15 1,15
Άλλες πληροφορίες
PD (μsec) 1,227
PRF (Hz) 2693
p
r
@PII
max
(MPa) 2,30
d
eq
@Pll
max
(cm) 0,427
Εστιακό μήκος FL
x
(cm) 4,56 4,56 2,25
FL
y
(cm) 9,00 9,00 9,00
I
PA.3
@MI
max
(W/cm
2
)
225
Συνθήκες
ελέγχου
λειτουργίας
Έλεγχος 1: Τύπος εξέτασης Καρδ. Κοιλ. Καρδ. Κοιλ.
Έλεγχος 2: Βελτιστοποίηση Γενική Διείσδ. Γενική Γε νι κή
Έλεγχος 3: Βάθος 7 cm 7 cm 13 cm 5 cm
Έλεγχος 4: THI Ενεργ. Απενεργ. Ενεργ. Ενεργ.
Τα δεδομένα δεν ισχύουν για αυτόν τον μορφοτροπέα/τρόπο λειτουργίας.
Dansk Norsk Svenska Ελληνικά Русский rkçe
Ακουστική έξοδος 169
Πίνακας 11: Μοντέλο μορφοτροπέα: rP19xp Τρόπος λειτουργίας Color (Έγχρωμος)/CPD
Ετικέτα δείκτη M.I.
TIS TIB
TIC
Σάρωση
Χωρίς σάρωση
Χωρίς
σάρωση
A
aprt
1 A
aprt
>1
Καθολική μέγιστη τιμή δείκτη 1,5 1,6 3,8
Σχετιζόμενη ακουστική
παράμετρος
p
r.3
(MPa) 2,15
W
0
(mW) 134,3 174,1
ελάχιστο των [W
.3
(z
1
),
I
TA.3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm)
z@PII
.3max
4,3
d
eq
(z
sp
) (cm)
F
c
(MHz) 2,05 2,60 2,09
Διαστ. του A
aprt
X (cm) 1,34 0,63
Y (cm) 1,15 1,15
Άλλες πληροφορίες
PD (μsec) 1,662
PRF (Hz) 1526
p
r
@PII
max
(MPa) 2,91
d
eq
@Pll
max
(cm)
Εστιακό μήκος FL
x
(cm) 4,56 2,25
FL
y
(cm) 9,00 9,00
I
PA.3
@MI
max
(W/cm
2
)
355
Τα δεδομένα δεν ισχύουν για αυτόν τον μορφοτροπέα/τρόπο λειτουργίας.
170 Ακουστική έξοδος
Συνθήκες
ελέγχου
λειτουργίας
Έλεγχος 1: Τύπος εξέτασης Πνεύμονας Μαιευτ. Καρδ.
Έλεγχος 2: Τρόπος λειτουργίας CVD CVD CVD
Έλεγχος 3: Βελτιστοποίηση 2D/
Βάθος
Γενική/
13 cm
Γενική/
5 cm
Διείσδ./
5 cm
Έλεγχος 4: Πλάτος τομέα (THI) Δ/Ι Δ/Ι/Απε-
νεργοποι-
ημένο
Μεσαίο/
Ενεργο
-
ποιημένο
Έλεγχος 5: Βελτιστοποίηση
χρώματος/PRF
Χαμηλή/
273 Hz
Υψηλή/
2841 Hz
Υψηλή/
3571 Hz
Έλεγχος 6: Θέση/Μέγεθος
πλαισίου χρώματος
Καθ./Στενό Κάτω
μέρος/
Μικρό
Καθ./
Στενό
Πίνακας 11: Μοντέλο μορφοτροπέα: rP19xp Τρόπος λειτουργίας Color (Έγχρωμος)/CPD
Ετικέτα δείκτη M.I.
TIS TIB
TIC
Σάρωση
Χωρίς σάρωση
Χωρίς
σάρωση
A
aprt
1 A
aprt
>1
Τα δεδομένα δεν ισχύουν για αυτόν τον μορφοτροπέα/τρόπο λειτουργίας.
Dansk Norsk Svenska Ελληνικά Русский rkçe
Ακουστική έξοδος 171
Πίνακας 12: Μοντέλο μορφοτροπέα: rP19xp Τρόπος λειτουργίας: PW Doppler
Ετικέτα δείκτη M.I.
TIS TIB
TIC
Σάρωση
Χωρίς σάρωση
Χωρίς
σάρωση
A
aprt
1 A
aprt
>1
Καθολική μέγιστη τιμή δείκτη 1,5 1,9 4,0 3,2
Σχετιζόμενη ακουστική
παράμετρος
p
r.3
(MPa) 2,17
W
0
(mW) 192,5 211,8
ελάχιστο των [W
.3
(z
1
),
I
TA.3
(z
1
)]
(mW) 108,3
z
1
(cm) 1,9
Z
bp
(cm) 2,5
Z
sp
(cm) 5,10
z@PII
.3max
0,5
d
eq
(z
sp
) (cm) 0,60
F
c
(MHz) 2,08 3,69 2,06 2,04
Διαστ. του A
aprt
X (cm) 1,92 1,92 1,92
Y (cm) 1,15 1,15 1,15
Άλλες πληροφορίες
PD (μsec) 1,141
PRF (Hz) 1562
p
r
@PII
max
(MPa) 2,24
d
eq
@Pll
max
(cm) 0,54
Εστιακό μήκος FL
x
(cm) 11,51 11,51
FL
y
(cm) 9,00 9,00
I
PA.3
@MI
max
(W/cm
2
)
156
Συνθήκες
ελέγχου
λειτουργίας
Έλεγχος 1: Τύπος εξέτασης Κοιλ. Καρδ. Κοιλ. Κοιλ.
Έλεγχος 2: Μέγεθος όγκου
δείγματος
1 mm 7 mm 1 mm 1 mm
Έλεγχος 3: Θέση όγκου δείγματος Ζώνη 0
(13 mm)
Ζώνη 7
(115 mm)
Ζώνη 6
(96 mm)
Ζώνη 7
(115 mm)
Έλεγχος 4: PRF 1562 Hz 1008 Hz 1562 Hz 1562 Hz
Έλεγχος 5: TDI Απενεργ. Ενεργ. Απενεργ. Απενεργ.
Τα δεδομένα δεν ισχύουν για αυτόν τον μορφοτροπέα/τρόπο λειτουργίας.
172 Ακουστική έξοδος
Πίνακας 13: Μοντέλο μορφοτροπέα: rP19xp Τρόπος λειτουργίας: CW Doppler
Ετικέτα δείκτη M.I.
TIS TIB
TIC
Σάρωση
Χωρίς σάρωση
Χωρίς
σάρωση
A
aprt
1 A
aprt
>1
Καθολική μέγιστη τιμή δείκτη (α) 1,2 4,0 3,1
Σχετιζόμενη ακουστική
παράμετρος
p
r.3
(MPa) #
W
0
(mW) 130,6 134,7 125,7
ελάχιστο των [W
.3
(z
1
),
I
TA.3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm) 3,40
z@PII
.3max
#
d
eq
(z
sp
) (cm) 0,47
F
c
(MHz) # 2,00 2,00 2,00
Διαστ. του A
aprt
X (cm) 0,90 0,90 0,72
Y (cm) 1,15 1,15 1,15
Άλλες πληροφορίες
PD (μsec) #
PRF (Hz) #
p
r
@PII
max
(MPa) #
d
eq
@Pll
max
(cm) 0,47
Εστιακό μήκος FL
x
(cm) 22,01 1,30
FL
y
(cm) 9,00 9,00
I
PA.3
@MI
max
(W/cm
2
)
#
Συνθήκες
ελέγχου
λειτουργίας
Έλεγχος 1: Τύπος εξέτασης Καρδ. Καρδ. Καρδ.
Έλεγχος 2: Θέση όγκου δείγματος Ζώνη 11
(220 mm)
Ζώνη 10
(189 mm)
Ζώνη 0
(13 mm)
(α) Αυτός ο δείκτης δεν απαιτείται για τον συγκεκριμένο τρόπο λειτουργίας. Η τιμή είναι <1.
# Δεν αναφέρονται δεδομένα για αυτήν τη συνθήκη λειτουργίας, καθώς η καθολική μέγιστη τιμή δείκτη δεν
αναφέρεται για το λόγο που παρατίθεται.ραμμή καθολικής μέγιστης τιμής δείκτη αναφοράς).
Τα δεδομένα δεν ισχύουν για αυτόν τον μορφοτροπέα/τρόπο λειτουργίας.
Dansk Norsk Svenska Ελληνικά Русский rkçe
Ακουστική έξοδος 173
Πίνακας 14: Μοντέλο μορφοτροπέα: rP19xp (κογχική χρήση), Τρόπος λειτουργίας: 2D
Ετικέτα δείκτη M.I.
TIS TIB
TIC
Σάρωση
Χωρίς σάρωση
Χωρίς
σάρωση
A
aprt
1 A
aprt
>1
Καθολική μέγιστη τιμή δείκτη 0,17 0,026 0,057
Σχετιζόμενη ακουστική
παράμετρος
p
r.3
(MPa) 0,26
W
0
(mW) 2,35 3,88
ελάχιστο των [W
.3
(z
1
),
I
TA.3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm)
z@PII
.3max
4,00
d
eq
(z
sp
) (cm)
F
c
(MHz) 2,34 2,33 2,34
Διαστ. του A
aprt
X (cm) 1,92 1,92
Y (cm) 1,15 1,15
Άλλες πληροφορίες
PD (μsec) 0,59
PRF (Hz) 2317
p
r
@PII
max
(MPa) 0,45
d
eq
@Pll
max
(cm)
Εστιακό μήκος FL
x
(cm) 16,77 16,77
FL
y
(cm) 9,00 9,00
I
PA.3
@MI
max
(W/cm
2
)
3,41
Συνθήκες
ελέγχου
λειτουργίας
Έλεγχος 1: Τύπος εξέτασης Κογχική Κογχική Κογχική
Έλεγχος 2: Βελτιστοποίηση Γενική Γενική Γενική
Έλεγχος 3: Βάθος 31 cm 31 cm 31 cm
Έλεγχος 4: THI Απενεργ. Απενεργ. Απε-
νεργ.
Τα δεδομένα δεν ισχύουν για αυτόν τον μορφοτροπέα/τρόπο λειτουργίας.
174 Ακουστική έξοδος
Πίνακας 15: Μοντέλο μορφοτροπέα: rP19xp (κογχική χρήση), Τρόπος λειτουργίας: M Mode
Ετικέτα δείκτη M.I.
TIS TIB
TIC
Σάρωση
Χωρίς σάρωση
Χωρίς
σάρωση
A
aprt
1 A
aprt
>1
Καθολική μέγιστη τιμή δείκτη 0,17 0,025 0,012 0,055
Σχετιζόμενη ακουστική
παράμετρος
p
r.3
(MPa) 0,26
W
0
(mW) 1,848 0,84 3,68
ελάχιστο των [W
.3
(z
1
),
I
TA.3
(z
1
)]
(mW) 0,41
z
1
(cm) 2,80
Z
bp
(cm) 2,52
Z
sp
(cm) 3,8
z@PII
.3max
4,00
d
eq
(z
sp
) (cm) 0,85
F
c
(MHz) 2,34 2,37 2,37 2,34 2,37
Διαστ. του A
aprt
X (cm) 1,92 1,92 1,92 1,92
Y (cm) 1,15 1,15 1,15 1,15
Άλλες πληροφορίες
PD (μsec) 0,59
PRF (Hz) 1600
p
r
@PII
max
(MPa) 0,45
d
eq
@Pll
max
(cm) 0,58
Εστιακό μήκος FL
x
(cm) 14,0 14,0 14,0
FL
y
(cm) 9,0 9,0 9,0
I
PA.3
@MI
max
(W/cm
2
)
3,41
Συνθήκες
ελέγχου
λειτουργίας
Έλεγχος 1: Τύπος εξέτασης Κογχική Κογχική Κογχική Κογχική
Έλεγχος 2: Βελτιστοποίηση Γενική Γενική Γενική Γενική
Έλεγχος 3: Βάθος 31 cm 25 cm 31 cm 25 cm
Έλεγχος 4: THI Απενεργ. Απενεργ. Απενεργ. Απε-
νεργ.
Τα δεδομένα δεν ισχύουν για αυτόν τον μορφοτροπέα/τρόπο λειτουργίας.
Dansk Norsk Svenska Ελληνικά Русский rkçe
Ακουστική έξοδος 175
Πίνακας 16: Μοντέλο μορφοτροπέα: rP19xp (κογχική χρήση), Τρόπος λειτουργίας: Color (Έγχρωμος)/CPD
Ετικέτα δείκτη M.I.
TIS TIB
TIC
Σάρωση
Χωρίς σάρωση
Χωρίς
σάρωση
A
aprt
1 A
aprt
>1
Καθολική μέγιστη τιμή δείκτη 0,20 0,055 0,12
Σχετιζόμενη ακουστική
παράμετρος
p
r.3
(MPa) 0,28
W
0
(mW) 5,55 5,77
ελάχιστο των [W
.3
(z
1
),
I
TA.3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm)
z@PII
.3max
0,4
d
eq
(z
sp
) (cm)
F
c
(MHz) 2,07 2,068 2,068
Διαστ. του A
aprt
X (cm) 0,96 0,96
Y (cm) 1,15 1,15
Άλλες πληροφορίες
PD (μsec) 1,55
PRF (Hz) 6301
p
r
@PII
max
(MPa) 0,29
d
eq
@Pll
max
(cm)
Εστιακό μήκος FL
x
(cm) 1,3 1,3
FL
y
(cm) 9,0 9,0
I
PA.3
@MI
max
(W/cm
2
)
2,58
Συνθήκες
ελέγχου
λειτουργίας
Έλεγχος 1: Τύπος εξέτασης Κογχική Κογχική Κογχική
Έλεγχος 2: Τρόπος λειτουργίας CVD CVD CVD
Έλεγχος 3: Βελτιστοποίηση 2D/
Βάθος
Γενική/5 cm Γενική/
5 cm
Γενική/
5 cm
Έλεγχος 4: Βελτιστοποίηση
χρώματος/PRF
Μεσαία/
2778 Hz
Μέτρια/
2778 Hz
Μέτρια/
2778 Hz
Έλεγχος 5: Θέση/Μέγεθος
πλαισίου χρώματος
Προεπιλεγ-
μένο/
Επάνω
Προεπι-
λεγ-
μένο/
Επάνω
Προεπι-
λεγ-
μένο/
Επάνω
Τα δεδομένα δεν ισχύουν για αυτόν τον μορφοτροπέα/τρόπο λειτουργίας.
176 Ακουστική έξοδος
Πίνακας 17: Μοντέλο μορφοτροπέα: rP19xp (κογχική χρήση), Τρόπος λειτουργίας: PW Doppler
Ετικέτα δείκτη M.I.
TIS TIB
TIC
Σάρωση
Χωρίς σάρωση
Χωρίς
σάρωση
A
aprt
1 A
aprt
>1
Καθολική μέγιστη τιμή δείκτη 0,19 0,22 0,56 0,51
Σχετιζόμενη ακουστική
παράμετρος
p
r.3
(MPa) 0,28
W
0
(mW) 33,8 34,4
ελάχιστο των [W
.3
(z
1
),
I
TA.3
(z
1
)]
(mW) 21,89
z
1
(cm) 3,00
Z
bp
(cm) 2,52
Z
sp
(cm) 3,8
z@PII
.3max
0,8
d
eq
(z
sp
) (cm) 0,79
F
c
(MHz) 2,11 2,09 2,09 2,09
Διαστ. του A
aprt
X (cm) 1,92 1,92 1,92
Y (cm) 1,15 1,15 1,15
Άλλες πληροφορίες
PD (μsec) 3,67
PRF (Hz) 3906
p
r
@PII
max
(MPa) 0,29
d
eq
@Pll
max
(cm) 0,69
Εστιακό μήκος FL
x
(cm) 22,0 27,3
FL
y
(cm) 9,0 9,0
I
PA.3
@MI
max
(W/cm
2
)
2,43
Συνθήκες
ελέγχου
λειτουργίας
Έλεγχος 1: Τύπος εξέτασης Κογχική Κογχική Κογχική Κογχική
Έλεγχος 2: Μέγεθος όγκου
δείγματος
3 mm 9 mm 9 mm 7 mm
Έλεγχος 3: Θέση όγκου δείγματος Ζώνη 1
(23 mm)
Ζώνη 11
(220 mm)
Ζώνη 11
(220 mm)
Ζώνη 13
(273
mm)
Έλεγχος 4: PRF 3906 Hz 2604 Hz 2604 Hz 1953 Hz
Τα δεδομένα δεν ισχύουν για αυτόν τον μορφοτροπέα/τρόπο λειτουργίας.
Dansk Norsk Svenska Ελληνικά Русский rkçe
Введение 177
Дополнение к руководству пользователя дат-
чика rP19xp SonoSite X-Porte
Введение .................................................................................................................................................... 177
Условные обозначения в документе ................................................................................................................................ 177
Помощь .......................................................................................................................................................................................... 178
Режимы визуализации ............................................................................................................................ 179
Очистка и дезинфекция ........................................................................................................................... 180
Меры безопасности .................................................................................................................................. 180
Совместимые принадлежности и периферийное оборудование ..................................................................... 181
Акустическая мощность .......................................................................................................................... 181
Указания по снижению значений MI (механического индекса) и TI (теплового индекса) ...................... 181
Отображение уровня выходного сигнала ..................................................................................................................... 182
Таблицы акустической мощности ..................................................................................................................................... 183
Введение
Данное дополнение к руководству пользователя содержит информацию о датчике rP19xp,
совместимом с ультразвуковой системой SonoSite X-Porte.
Условные обозначения в документе
В документе присутствуют перечисленные ниже условные обозначения.
Под заголовком ПРЕДУПРЕЖДЕНИЕ описаны меры предосторожности для предупреждения травм и
летального исхода.
Под заголовком Внимание! описаны меры предосторожности для защиты оборудования.
Под заголовком Примечание изложена дополнительная информация.
Пронумерованные или обозначенные буквами действия должны выполняться в определенном
порядке.
В маркированных списках информация представлена в формате списка инструкций, однако их
выполнение не предполагает соблюдения последовательности.
Описание символов маркировки на изделии см. в руководстве пользователя в разделе «Символы
маркировки».
178 Введение
Помощь
Информация для связи со службой технической поддержки FUJIFILM SonoSite:
Напечатано в США
Те л е ф он
(США или Канада)
+1-877-657-8118
Те л е ф он
(за пределами США
и
Канады)
+1-425-951-1330. Можно также позвонить в местное
представительство
Факс +1-425-951-6700
Электронная почта ffss-ser[email protected]
Сайт www.sonosite.com
Сервисный центр
в
Европе
Общий: +31 20 751 2020
Техническая поддержка на английском языке:
+44 14 6234 1151
Техническая поддержка на французском языке:
+33 1 8288 0702
Техническая поддержка на немецком языке:
+49 69 8088 4030
Техническая поддержка на итальянском языке:
+39 02 9475 3655
Техническая поддержка на испанском языке:
+34 91123 8451
Сервисный центр
в
Азии
+656380-5581
Dansk Norsk Svenska Ελληνικά Русский rkçe
Режимы визуализации 179
Режимы визуализации
Таблица 1. Доступные типы исследования и режимы визуализации
Датчик
Тип исследова-
ния
Режим визуализации
Двухмерный
режим
M Mode
Режим цветного
картирования
a
Доплеровский
режим PW
b
Доплеров-
ский режим
CW
rP19xp Брюшная
полость
CVD, CPD
Кардиологиче-
ское
CVD, Var
Легкие CVD, CPD
Акушерство CVD, CPD
Орбитальный CVD, CPD
Транскраниаль-
ный
CVD, CPD
a
Var = доплеровский режим цветного картирования с отображением отклонений, доступный только для
кардиологических исследований. CPD = доплеровский режим цветного энергетического картирования,
доступный для всех исследований, кроме кардиологических. CVD = доплеровский режим цветного скоростного
картирования.
b
Для кардиологического типа исследований, кроме того, доступен импульсно-волновой доплеровский режим
тканевой визуализации (PW TDI).
Примечание Датчик rP19xp оснащен направляющей для игл. Дополнительные сведения
см. в документе Using CIVCO Products with FUJIFILM SonoSite Systems
(Использование изделий CIVCO с системами FUJIFILM SonoSite).
180 Очистка и дезинфекция
Очистка и дезинфекция
Меры безопасности
Таблица 2. Утвержденные средства очистки
Изделие Совместимый датчик
Минимальное время влажной
обработки
a
SaniCloth AF3
b
rP19xp 3 мин.
PI-Spray II rP19xp 10 мин.
a
В целях обеспечения максимальной эффективности очищаемый компонент должен оставаться увлажненным
с помощью дезинфицирующего средства в течение определенного минимального периода времени.
b
Допускается использовать с дезинфицирующим средством промежуточного уровня против микобактерий.
Полный список наиболее современных чистящих и дезинфицирующих средств см. в документе по чистящим и
дезинфицирующим средствам по адресу www.sonosite.com.
Таблица 3. Утвержденные совместимые высокоуровневые дезинфицирующие средства
Дезинфици-
рующее
средство
a
Совместимый датчик
Темпера-
тура
Время замачивания в дезин-
фицирующем средстве
Cidex rP19xp 25 °C 45 мин.
Cidex OPA rP19xp 20 °C 12 мин.
a
Полный список наиболее современных чистящих и дезинфицирующих средств см. в документе по чистящим и
дезинфицирующим средствам по адресу
www.sonosite.com.
ПРЕДУПРЕЖДЕНИЕ Во избежание повреждения устройства или причинения травм
пациенту не используйте держатели направляющей для игл
датчиков rP19xp при обследовании пациентов с
кардиостимуляторами или электронно-медицинскими имплантами.
Держатель направляющей для игл датчиков rP19xp содержит
магнит, обеспечивающий правильную ориентацию держателя на
датчике. Магнитное поле в непосредственной близости от
кардиостимулятора или электронно-медицинского импланта может
оказывать на них неблагоприятное воздействие.
Dansk Norsk Svenska Ελληνικά Русский rkçe
Акустическая мощность 181
Совместимые принадлежности и периферийное оборудование
Акустическая мощность
Указания по снижению значений MI (механического индекса) и TI
(теплового индекса)
Таблица 4. Принадлежности и периферийное оборудование
Описание Максимальная длина кабеля
Датчик rP19xp
a
1,8 м
a
Для датчиков максимальная длина кабеля измеряется между эластичными муфтами у штекеров. В указанную
длину не входит длина кабеля в следующих местах: под эластичными муфтами у штекеров, внутри корпуса дат
-
чика и внутри разъема датчика.
Таблица 5. Указания по снижению значения механического индекса (MI)
Датчик Глубина
rP19xp
Уменьшите или понизьте настройку параметра, чтобы сократить значение MI.
Увеличьте или повысьте настройку параметра, чтобы сократить значение MI.
182 Акустическая мощность
Отображение уровня выходного сигнала
Таблица 6. Указания по снижению значения теплового индекса (TI)
Датчик
Параметры CPD
Парамет
ры PW
Ширина
окна
Высота
окна
Глубина
окна
PRF Глуби на
Оптими-
зация
rP19xp
(PRF)
Уменьшите или понизьте настройку параметра, чтобы сократить значение TI.
Увеличьте или повысьте настройку параметра, чтобы сократить значение TI.
Таблица 7. TI или MI 1,0
Датчик Индекс
ДвухM Mo
deмерный
режим/
M Mode
CPD/
Режим
цветного
картирова-
ния
Доплеров-
ский
режим PW
Доплеров-
ский
режим CW
rP19xp MI Да Да Да Нет
TIC, TIB или TIS Да Да Да Да
Таблица 8. Повышение температуры поверхности датчика, внешнее применение (°C )
Те с т rP19xp
Спокойный воздух 15,8
Смоделированное
использование
8,8
Dansk Norsk Svenska Ελληνικά Русский rkçe
Акустическая мощность 183
Таблицы акустической мощности
Таблица 9. Модель датчика: rP19xp, режим работы: Двухмерный режим
Метка индекса M.I.
TIS TIB
TIC
При
скани
-
рова-
нии
Без сканирова-
ния Без скани-
рования
A
aprt
1 A
aprt
>1
Значение индекса глобального макси-
мума
1,5 1,2 2,9
Соответствующий акустический
параметр
p
r.3
(МПа) 1,95
W
0
(мВт) 120,0 190,8
мин. из [W
.3
(z
1
),I
TA.3
(z
1
)] (мВт)
z
1
(см)
Z
bp
(см)
Z
sp
(см)
z@PII
.3max
2,6
d
eq
(z
sp
) (см)
F
c
(МГц) 1,72 2,02 1,80
Разм. A
aprt
X (см) 1,92 1,92
Y (см) 1,15 1,15
Другая информация
PD (мкс) 1,227
PRF ц) 2933
p
r
@PII
max
(МПа) 2,30
d
eq
@Pll
max
(см)
Фокусное расстояние FL
x
(см) 3,42 3,42
FL
y
(см) 9,00 9,00
I
PA.3
@MI
max
(Вт/см
2
)
225
Эксплуатация
Элемент управления
Условия
Элемент управления 1. Тип
исследования
Crd Abd Abd
Элемент управления 2. Оптими-
зация
Gen Pen Gen
Элемент управления 3. Глубина 7 см 5 см 5 см
Элемент управления 4. THI Вкл. Выкл. Вкл.
Элемент управления 5. Ширина
сектора
Полн. Непри-
менимо
Непри-
менимо
Данные неприменимы к этому датчику/режиму.
184 Акустическая мощность
Таблица 10. Модель датчика: rP19xp, режим работы: M Mode
Метка индекса M.I.
TIS TIB
TIC
При
ска
-
ниро-
вании
Без сканирова-
ния Без скани-
рования
A
aprt
1 A
aprt
>1
Значение индекса глобального макси-
мума
1,5 1,1 0,9 3,0
Соответствующий акустический
параметр
p
r.3
(МПа) 1,95
W
0
(мВт) 105 9,8 25,4 180,5
мин. из [W
.3
(z
1
),I
TA.3
(z
1
)] (мВт)
z
1
(см)
Z
bp
(см)
Z
sp
(см) 3,02
z@PII
.3max
2,6
d
eq
(z
sp
) (см) 0,444
F
c
(МГц) 1,72 2,09 2,09 1,732 1,75
Разм. A
aprt
X (см) 1,92 0,78 1,02 1,92
Y (см) 1,15 1,15 1,15 1,15
Другая информация
PD (мкс) 1,227
PRF ц) 2693
p
r
@PII
max
(МПа) 2,30
d
eq
@Pll
max
(см) 0,427
Фокусное расстояние FL
x
(см) 4,56 4,56 2,25
FL
y
(см) 9,00 9,00 9,00
I
PA.3
@MI
max
(Вт/см
2
)
225
Эксплуатация
Элемент управления
Условия
Элемент управления 1. Тип
исследования
Crd Abd Crd Abd
Элемент управления 2. Оптими-
зация
Gen Pen Gen Gen
Элемент управления 3. Глубина 7 см 7 см 13 см 5 см
Элемент управления 4. THI Вкл. Выкл. Вкл. Вкл.
Данные неприменимы к этому датчику/режиму.
Dansk Norsk Svenska Ελληνικά Русский rkçe
Акустическая мощность 185
Таблица 11. Модель датчика: rP19xp, режим работы: цветное картирование/CPD
Метка индекса M.I.
TIS TIB
TIC
При
скани
-
рова-
нии
Без сканирова-
ния Без скани-
рования
A
aprt
1 A
aprt
>1
Значение индекса глобального макси-
мума
1,5 1,6 3,8
Соответствующий акустический
параметр
p
r.3
(МПа) 2,15
W
0
(мВт) 134,3 174,1
мин. из [W
.3
(z
1
),I
TA.3
(z
1
)] (мВт)
z
1
(см)
Z
bp
(см)
Z
sp
(см)
z@PII
.3max
4,3
d
eq
(z
sp
) (см)
F
c
(МГц) 2,05 2,60 2,09
Разм. A
aprt
X (см) 1,34 0,63
Y (см) 1,15 1,15
Другая информация
PD кс) 1,662
PRF ц) 1526
p
r
@PII
max
(МПа) 2,91
d
eq
@Pll
max
(см)
Фокусное расстояние FL
x
(см) 4,56 2,25
FL
y
(см) 9,00 9,00
I
PA.3
@MI
max
(Вт/см
2
)
355
Данные неприменимы к этому датчику/режиму.
186 Акустическая мощность
Эксплуатация
Элемент управления
Условия
Элемент управления 1. Тип
исследования
Легкие OB Crd
Элемент управления 2. Режим CVD CVD CVD
Элемент управления 3. Двухмер-
ная оптимизация/глубина
Gen/
13 см
Gen/
5 см
Pen/
5 см
Элемент управления 4. Ширина
сектора/THI
Неприме-
нимо
Непри-
менимо/
Выкл.
Средн./
Вкл.
Элемент управления 5. Оптими-
зация цвета/PRF
Низк./
273 Гц
Выс./
2841
Гц
Выс./
3571
Гц
Элемент управления 6. Положе-
ние/размер цветового окна
Опр./узк. Нижн./
мал.
Опр./
узк.
Таблица 11. Модель датчика: rP19xp, режим работы: цветное картирование/CPD
Метка индекса M.I.
TIS TIB
TIC
При
скани-
рова-
нии
Без сканирова-
ния
Без скани-
рования
A
aprt
1 A
aprt
>1
Данные неприменимы к этому датчику/режиму.
Dansk Norsk Svenska Ελληνικά Русский rkçe
Акустическая мощность 187
Таблица 12. Модель датчика: rP19xp, режим работы: Доплеровский режим PW
Метка индекса M.I.
TIS TIB
TIC
При
ска
-
ниро-
вании
Без сканирова-
ния
Без ска-
нирова-
ния
A
aprt
1 A
aprt
>1
Значение индекса глобального макси-
мума
1,5 1,9 4,0 3,2
Соответствующий акустический
параметр
p
r.3
(МПа) 2,17
W
0
(мВт) 192,5 211,8
мин. из [W
.3
(z
1
),I
TA.3
(z
1
)] (мВт) 108,3
z
1
(см) 1,9
Z
bp
(см) 2,5
Z
sp
(см) 5,10
z@PII
.3max
0,5
d
eq
(z
sp
) (см) 0,60
F
c
(МГц) 2,08 3,69 2,06 2,04
Разм. A
aprt
X (см) 1,92 1,92 1,92
Y (см) 1,15 1,15 1,15
Другая информация
PD (мкс) 1,141
PRF ц) 1562
p
r
@PII
max
(МПа) 2.24
d
eq
@Pll
max
(см) 0,54
Фокусное расстояние FL
x
(см) 11,51 11,51
FL
y
(см) 9,00 9,00
I
PA.3
@MI
max
(Вт/см
2
)
156
Эксплуатация
Элемент управления
Условия
Элемент управления 1. Тип
исследования
Abd Crd Abd Abd
Элемент управления 2. Вели-
чина контрольного объема
1 мм 7 мм 1 мм 1 мм
Элемент управления 3. Позиция
контрольного объема
Зона 0
(13 мм)
Зона 7
(115 мм)
Зона 6
(96 мм)
Зона 7
(115 мм)
Элемент управления 4. PRF 1562 Гц 1008 Гц 1562 Гц 1562 Гц
Элемент управления 5. TDI Выкл. Вкл. Выкл. Выкл.
Данные неприменимы к этому датчику/режиму.
188 Акустическая мощность
Таблица 13. Модель датчика: rP19xp, режим работы: Доплеровский режим CW
Метка индекса M.I.
TIS TIB
TIC
При
ска
-
ниро-
вании
Без сканирова-
ния
Без ска-
нирова-
ния
A
aprt
1 A
aprt
>1
Значение индекса глобального макси-
мума
(a) 1,2 4,0 3,1
Соответствующий акустический
параметр
p
r.3
(МПа) #
W
0
(мВт) 130,6 134,7 125,7
мин. из [W
.3
(z
1
),I
TA.3
(z
1
)] (мВт)
z
1
(см)
Z
bp
(см)
Z
sp
(см) 3,40
z@PII
.3max
#
d
eq
(z
sp
) (см) 0,47
F
c
(МГц) # 2,00 2,00 2,00
Разм. A
aprt
X (см) 0,90 0,90 0,72
Y (см) 1,15 1,15 1,15
Другая информация
PD (мкс) #
PRF ц) #
p
r
@PII
max
(МПа) #
d
eq
@Pll
max
(см) 0,47
Фокусное расстояние FL
x
(см) 22,01 1,30
FL
y
(см) 9,00 9,00
I
PA.3
@MI
max
(Вт/см
2
)
#
Эксплуатация
Элемент управления
Условия
Элемент управления 1. Тип
исследования
Crd Crd Crd
Элемент управления 2. Позиция
контрольного объема
Зона 11
(220 мм)
Зона 10
(189 мм)
Зона 0
(13 мм)
(a) Этот индекс не требуется для этого рабочего режима; значение составляет < 1.
# Данных относительно этого режима работы нет, поскольку значение индекса глобального максимума
отсутствует по указанной причине. (См. строку со значением индекса глобального максимума.)
Данные неприменимы к этому датчику/режиму.
Dansk Norsk Svenska Ελληνικά Русский rkçe
Акустическая мощность 189
Таблица 14. Модель датчика: rP19xp (для орбитальных исследований), режим работы: Двухмерный
режим
Метка индекса M.I.
TIS TIB
TIC
При
ска
-
ниро-
вании
Без сканирова-
ния Без скани-
рования
A
aprt
1 A
aprt
>1
Значение индекса глобального макси-
мума
0,17 0,026 0,057
Соответствующий акустический
параметр
p
r.3
(МПа) 0,26
W
0
(мВт) 2,35 3,88
мин. из [W
.3
(z
1
),I
TA.3
(z
1
)] (мВт)
z
1
(см)
Z
bp
(см)
Z
sp
(см)
z@PII
.3max
4,00
d
eq
(z
sp
) (см)
F
c
(МГц) 2,34 2,33 2,34
Разм. A
aprt
X (см) 1,92 1,92
Y (см) 1,15 1,15
Другая информация
PD (мкс) 0,59
PRF ц) 2317
p
r
@PII
max
(МПа) 0,45
d
eq
@Pll
max
(см)
Фокусное расстояние FL
x
(см) 16,77 16,77
FL
y
(см) 9,00 9,00
I
PA.3
@MI
max
(Вт/см
2
)
3,41
Эксплуатация
Элемент управления
Условия
Элемент управления 1. Тип
исследования
Orb Orb Orb
Элемент управления 2. Оптими-
зация
Gen Gen Gen
Элемент управления 3. Глубина 31 см 31 см 31 см
Элемент управления 4. THI Выкл. Выкл. Выкл.
Данные неприменимы к этому датчику/режиму.
190 Акустическая мощность
Таблица 15. Модель датчика: rP19xp (для орбитальных исследований), режим работы: M Mode
Метка индекса M.I.
TIS TIB
TIC
При
ска
-
ниро-
вании
Без сканирова-
ния Без скани-
рования
A
aprt
1 A
aprt
>1
Значение индекса глобального макси-
мума
0,17 0,025 0,012 0,055
Соответствующий акустический
параметр
p
r.3
(МПа) 0,26
W
0
(мВт) 1,848 0,84 3,68
мин. из [W
.3
(z
1
),I
TA.3
(z
1
)] (мВт) 0,41
z
1
(см) 2,80
Z
bp
(см) 2,52
Z
sp
(см) 3,8
z@PII
.3max
4,00
d
eq
(z
sp
) (см) 0,85
F
c
(МГц) 2,34 2,37 2,37 2,34 2,37
Разм. A
aprt
X (см) 1,92 1,92 1,92 1,92
Y (см) 1,15 1,15 1,15 1,15
Другая информация
PD (мкс) 0,59
PRF ц) 1600
p
r
@PII
max
(МПа) 0,45
d
eq
@Pll
max
(см) 0,58
Фокусное расстояние FL
x
(см) 14,0 14,0 14,0
FL
y
(см) 9,0 9,0 9,0
I
PA.3
@MI
max
(Вт/см
2
)
3,41
Эксплуатация
Элемент управления
Условия
Элемент управления 1. Тип
исследования
Orb Orb Orb Orb
Элемент управления 2. Оптими-
зация
Gen Gen Gen Gen
Элемент управления 3. Глубина 31 см 25 см 31 см 25 см
Элемент управления 4. THI Выкл. Выкл. Выкл. Выкл.
Данные неприменимы к этому датчику/режиму.
Dansk Norsk Svenska Ελληνικά Русский rkçe
Акустическая мощность 191
Таблица 16. Модель датчика: rP19xp (для орбитальных исследований), режим работы: цветное
картирование/CPD
Метка индекса M.I.
TIS TIB
TIC
При
скани
-
рова-
нии
Без сканирова-
ния
Без ска-
нирова-
ния
A
aprt
1 A
aprt
>1
Значение индекса глобального макси-
мума
0,20 0,055 0,12
Соответствующий акустический
параметр
p
r.3
(МПа) 0,28
W
0
(мВт) 5,55 5,77
мин. из [W
.3
(z
1
),I
TA.3
(z
1
)] (мВт)
z
1
(см)
Z
bp
(см)
Z
sp
(см)
z@PII
.3max
0,4
d
eq
(z
sp
) (см)
F
c
(МГц) 2,07 2,068 2,068
Разм. A
aprt
X (см) 0,96 0,96
Y (см) 1,15 1,15
Другая информация
PD (мкс) 1,55
PRF ц) 6301
p
r
@PII
max
(МПа) 0,29
d
eq
@Pll
max
(см)
Фокусное расстояние FL
x
(см) 1,3 1,3
FL
y
(см) 9,0 9,0
I
PA.3
@MI
max
(Вт/см
2
)
2,58
Данные неприменимы к этому датчику/режиму.
192 Акустическая мощность
Эксплуатация
Элемент управления
Условия
Элемент управления 1. Тип
исследования
Orb Orb Orb
Элемент управления 2. Режим CVD CVD CVD
Элемент управления 3. Двухмер-
ная оптимизация/глубина
Gen/5 см Gen/
5
см
Gen/
5
см
Элемент управления 4. Оптими-
зация цвета/PRF
Средн./
2778 Гц
Средн./
2778
Гц
Средн./
2778
Гц
Элемент управления 5. Положе-
ние/размер цветового окна
По умолча-
нию/сверху
По
умолча
-
нию/
сверху
По
умолча
-
нию/
сверху
Таблица 16. Модель датчика: rP19xp (для орбитальных исследований), режим работы: цветное
картирование/CPD
Метка индекса M.I.
TIS TIB
TIC
При
скани-
рова-
нии
Без сканирова-
ния
Без ска-
нирова-
ния
A
aprt
1 A
aprt
>1
Данные неприменимы к этому датчику/режиму.
Dansk Norsk Svenska Ελληνικά Русский rkçe
Акустическая мощность 193
Таблица 17. Модель датчика: rP19xp (для орбитальных исследований), режим работы: Доплеровский
режим PW
Метка индекса M.I.
TIS TIB
TIC
При
ска
-
ниро-
вании
Без сканирова-
ния Без скани-
рования
A
aprt
1 A
aprt
>1
Значение индекса глобального макси-
мума
0,19 0,22 0,56 0,51
Соответствующий акустический
параметр
p
r.3
(МПа) 0,28
W
0
(мВт) 33,8 34,4
мин. из [W
.3
(z
1
),I
TA.3
(z
1
)] (мВт) 21,89
z
1
(см) 3,00
Z
bp
(см) 2,52
Z
sp
(см) 3,8
z@PII
.3max
0,8
d
eq
(z
sp
) (см) 0,79
F
c
(МГц) 2,11 2,09 2,09 2,09
Разм. A
aprt
X (см) 1,92 1,92 1,92
Y (см) 1,15 1,15 1,15
Другая информация
PD (мкс) 3,67
PRF ц) 3906
p
r
@PII
max
(МПа) 0,29
d
eq
@Pll
max
(см) 0,69
Фокусное расстояние FL
x
(см) 22,0 27,3
FL
y
(см) 9,0 9,0
I
PA.3
@MI
max
(Вт/см
2
)
2,43
Эксплуатация
Элемент управления
Условия
Элемент управления 1. Тип
исследования
Orb Orb Orb Orb
Элемент управления 2. Вели-
чина контрольного объема
3 мм 9 мм 9 мм 7 мм
Элемент управления 3. Позиция
контрольного объема
Зона 1
(23 мм)
Зона
11
(220 м
м)
Зона
11
(220 мм)
Зона
13
(273 м
м)
Элемент управления 4. PRF 3906 Гц 2604 Гц 2604 Гц 1953 Гц
Данные неприменимы к этому датчику/режиму.
194 Акустическая мощность
Dansk Norsk Svenska Ελληνικά Русский rkçe
Giriş 195
SonoSite X-Porte rP19xp Dönüştürücü Kullanıcı
Kılavuzu Eki
Giriş ............................................................................................................................................................. 195
Belge kuralları ......................................................................................................................................................................................... 195
Yardım Alma ............................................................................................................................................................................................ 196
Görüntüleme modları ................................................................................................................................ 197
Temizlik ve dezenfeksiyon ....................................................................................................................... 198
Güvenlik ...................................................................................................................................................... 198
Uyumlu aksesuarlar ve yan birimler ........................................................................................................................................... 199
Akustik çıktı ............................................................................................................................................... 199
MI ve TI değerini azaltma kuralları .............................................................................................................................................. 199
Çıktı göstergesi ...................................................................................................................................................................................... 200
Akustik çıktı tabloları ........................................................................................................................................................................... 201
Giriş
Bu kullanıcı kılavuzu ekinde SonoSite X-Porte ultrason sistemiyle uyumlu rP19xp dönüştürücüyle ilgili bilgiler
verilmektedir.
Belge kuralları
Bu belgede şu kurallar uygulanır.
Bir UYARI, yaralanma veya yaşam kaybını önlemek için gereken önlemleri açıklar.
Dikkat, ürünleri korumak için alınması gereken önlemleri açıklar.
Not, ek bilgiler sağlar.
Numaralandırılmış ve harflendirilmiş adımlar, belirli bir sırayla gerçekleştirilmelidir.
Madde imli listeler, liste biçiminde bilgiler sunar, ancak belirli bir dizilim ifade etmezler.
Ürün üzerinde görülen etiketleme sembollerinin açıklaması için bkz. ultrason sistemi kullanıcı kılavuzundaki
“Etiketleme Sembolleri”.
196 Giriş
Yardım Alma
Teknik destek için lütfen aşağıdaki numaraları arayarak FUJIFILM SonoSite’a başvurun:
ABD’de basılmıştır
Telefon
(ABD veya Kanada)
+1-877-657-8118
Telefon
(ABD veya Kanada
dışında)
+1-425-951-1330 veya yerel temsilcinizi arayın
Faks +1-425-951-6700
E-posta ffss-service@fujifilm.com
Web www.sonosite.com
Avrupa Servis Merkezi Ana: +31 20 751 2020
İngilizce destek: +44 14 6234 1151
Fransızca destek: +33 1 8288 0702
Almanca destek: +49 69 8088 4030
İtalyanca destek: +39 02 9475 3655
İspanyolca destek: +34 91 123 8451
Asya Servis Merkezi +65 6380-5581
Dansk Norsk Svenska Ελληνικά Русский rkçe
Görüntüleme modları 197
Görüntüleme modları
Tablo 1: Mevcut muayene türleri ve görüntüleme modları
Dönüştü-
rücü
Muayene
türü
Görüntüleme modu
2D
M Mode
Renkli
a
PW
Doppler
b
CW
Doppler
rP19xp Abdomen CVD, CPD
Kardiyak CVD, Var
Akciğer CVD, CPD
Obstetrik CVD, CPD
Göz Çukuru CVD, CPD
Kafa İçi CVD, CPD
a
Var = Renkli Doppler Varyansı, yalnızca kardiyak muayenede kullanılabilir. CPD = Renkli Güç Doppler,
kardiyak muayene türü hariç tüm muayenelerde kullanılabilir. CVD = Renkli Hızlı Doppler.
b
Kardiyak muayene türü için, PW TDI da kullanılabilir.
Not rP19xp dönüştürücü, iğne kılavuz desteğine sahiptir. Daha fazla bilgi için, bkz.
Using CIVCO Products with FUJIFILM SonoSite Systems (CIVCO Ürünlerini
FUJIFILM SonoSite Sistemleriyle Kullanma).
198 Temizlik ve dezenfeksiyon
Temizlik ve dezenfeksiyon
Güvenlik
Tablo 2: Onaylı temizleyiciler
Ürün Uyumlu dönüştürücü
Minimum ıslak temas süresi
a
SaniCloth AF3
b
rP19xp 3 dakika
PI-Spray II rP19xp 10 dakika
a
Maksimum etkinlik için, temizlenmekte olan bileşen, minimum süre için dezenfektanla ıslatılmış kalmalıdır.
b
Mikobakteri için ara seviye dezenfektan kullanımı için onaylı.
En güncel temizleyiciler ve dezenfektanların tam bir listesi için, www.sonosite.com adresindeki temizleyiciler ve
dezenfekte etme belgesine bakın.
Tablo 3: Onaylı yüksek seviyede uyumlu dezenfektanlar
Dezenfek-
tan
a
Uyumlu dönüştürücü Sıcaklık Dezenfektan batırma süresi
Cidex rP19xp
25
°
C
45 dakika
Cidex OPA rP19xp
20
°
C
12 dakika
a
En güncel temizleyiciler ve dezenfektanların tam listesi için, www.sonosite.com adresindeki temizleyiciler ve
dezenfeksiyon belgesine bakın.
UYARI Cihaza zarar gelmesini ve hastanın yaralanmasını önlemek için, pacemaker veya
medikal elektronik implantları bulunan hastalarda rP19xp iğne kılavuz desteği
kullanmayın. rP19xp dönüştürücüler için iğne kılavuz desteğinde, desteğin
dönüştürücü üzerinde doğru hizalanmasını sağlamak üzere bir mıknatıs bulunur.
Pacemaker veya medikal elektronik implantların doğrudan yakınında bulunan
manyetik alanın olumsuz etkisi olabilir.
Dansk Norsk Svenska Ελληνικά Русский rkçe
Akustik çıktı 199
Uyumlu aksesuarlar ve yan birimler
Akustik çıktı
MI ve TI değerini azaltma kuralları
Tablo 4: Aksesuarlar ve yan birimler
Tanım Maksimum Kablo Uzunluğu
rP19xp dönüştürücü
a
1,8 m
a
Dönüştürücüler için maksimum kablo uzunluğu gerginlik giderme kısımları arasında ölçülür. Belirtilen uzunluklar, aşa-
ğıdaki konumlardaki kablo uzunluklarını kapsamaz: gerginlik giderme kısımları altında, dönüştürücü muhafazası içinde
veya dönüştürücü bağlantısı içinde.
Tablo 5: Mekanik indeks (MI) değerini azaltma kuralları
Dönüştürücü Derinlik
rP19xp
MI değerini azaltmak için parametre ayarını azaltın veya düşürün.
MI değerini azaltmak için parametre ayarını yükseltin veya artırın.
200 Akustik çıktı
Çıktı göstergesi
Tablo 6: Termal indeks (TI) değerini azaltma kuralları
Dönüştü-
rücü
CPD Ayarları
PW
Ayarları
Kutu
Genişliği
Kutu
Yüksek-
liği
Kutu
Derinliği
PRF Derinlik
Optimi-
zasyon
rP19xp
(PRF)
TI değerini azaltmak için parametre ayarını azaltın veya düşürün.
TI değerini azaltmak için parametre ayarını yükseltin veya artırın.
Tablo 7: TI veya MI 1,0
Dönüştürücü İndeks
2D/
M Mode
CPD/
Renk
PW
Doppler
CW
Doppler
rP19xp MI Evet Evet Evet Hayır
TIC, TIB veya TIS Evet Evet Evet Evet
Tablo 8: Dönüştürücü Yüzey Sıcaklığı Yüksekliği, Harici Kullanım (°C )
Test rP19xp
Durgun hava 15,8
Simülasyonlu
kullanım
8,8
Dansk Norsk Svenska Ελληνικά Русский rkçe
Akustik çıktı 201
Akustik çıktı tabloları
Tablo 9: Dönüştürücü Modeli: rP19xp İşletim Modu: 2D
İndeks Etiketi M. I.
TIS TIB
TIC
Tarama
Taramasız
Taramasız
A
aprt
1 A
aprt
>1
Global Maksimum İndeks Değeri 1,5 1,2 2,9
İlişkili Akustik
Parametre
p
r.3
(MPa) 1,95
W
0
(mW) 120,0 190,8
minimum [W
.3
(z
1
),
I
TA.3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm)
z@PII
.3maks
2,6
d
eq
(z
sp
) (cm)
F
c
(MHz) 1,72 2,02 1,80
A
aprt
boyutları X (cm) 1,92 1,92
Y (cm) 1,15 1,15
Diğer Bilgiler
PD (μsaniye) 1,227
PRF (Hz) 2933
p
r
@PII
maks
(MPa) 2,30
d
eq
@Pll
maks
(cm)
Fokal Uzunluk FL
x
(cm) 3,42 3,42
FL
y
(cm) 9,00 9,00
I
PA.3
@MI
maks
(W/cm
2
)
225
Çalıştırma
Denetim
Koşulları
Denetim 1: Muayene Türü Crd Abd Abd
Denetim 2: Optimizasyon Gen Pen Gen
Denetim 3: Derinlik 7 cm 5 cm 5 cm
Denetim 4: THI Açık Kapalı ık
Denetim 5: Sektör Genişliği Tam Yok Yok
Veriler bu dönüştürücü/mod için uygulanabilir değildir.
202 Akustik çıktı
Tablo 10: Dönüştürücü Modeli: rP19xp İşletim Modu: M Mode
İndeks Etiketi M. I.
TIS TIB
TIC
Tarama
Taramasız
Taramasız
A
aprt
1 A
aprt
>1
Global Maksimum İndeks Değeri 1,5 1,1 0,9 3,0
İlişkili Akustik
Parametre
p
r.3
(MPa) 1,95
W
0
(mW) 105 9,8 25,4 180,5
minimum [W
.3
(z
1
),
I
TA.3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm) 3,02
z@PII
.3maks
2,6
d
eq
(z
sp
) (cm) 0,444
F
c
(MHz) 1,72 2,09 2,09 1,732 1,75
A
aprt
boyutları X (cm) 1,92 0,78 1,02 1,92
Y (cm) 1,15 1,15 1,15 1,15
Diğer Bilgiler
PD (μsaniye) 1,227
PRF (Hz) 2693
p
r
@PII
maks
(MPa) 2,30
d
eq
@Pll
maks
(cm) 0,427
Fokal Uzunluk FL
x
(cm) 4,56 4,56 2,25
FL
y
(cm) 9,00 9,00 9,00
I
PA.3
@MI
maks
(W/cm
2
)
225
Çalıştırma
Denetim
Koşulları
Denetim 1: Muayene Türü Crd Abd Crd Abd
Denetim 2: Optimizasyon Gen Pen Gen Gen
Denetim 3: Derinlik 7 cm 7 cm 13 cm 5 cm
Denetim 4: THI Açık Kapalı Açık ık
Veriler bu dönüştürücü/mod için uygulanabilir değildir.
Dansk Norsk Svenska Ελληνικά Русский rkçe
Akustik çıktı 203
Tablo 11: Dönüştürücü Modeli: rP19xp İşletim Modu: Renkli/CPD
İndeks Etiketi M. I.
TIS TIB
TIC
Tarama
Taramasız
Taramasız
A
aprt
1 A
aprt
>1
Global Maksimum İndeks Değeri 1,5 1,6 3,8
İlişkili Akustik
Parametre
p
r.3
(MPa) 2,15
W
0
(mW) 134,3 174,1
minimum [W
.3
(z
1
),
I
TA.3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm)
z@PII
.3maks
4,3
d
eq
(z
sp
) (cm)
F
c
(MHz) 2,05 2,60 2,09
A
aprt
boyutları X (cm) 1,34 0,63
Y (cm) 1,15 1,15
Diğer Bilgiler
PD (μsaniye
)
1,662
PRF (Hz) 1526
p
r
@PII
maks
(MPa) 2,91
d
eq
@Pll
maks
(cm)
Fokal Uzunluk FL
x
(cm) 4,56 2,25
FL
y
(cm) 9,00 9,00
I
PA.3
@MI
maks
(W/cm
2
)
355
Veriler bu dönüştürücü/mod için uygulanabilir değildir.
204 Akustik çıktı
Çalıştırma
Denetim
Koşulları
Denetim 1: Muayene Türü Akciğer OB Crd
Denetim 2: Mod CVD CVD CVD
Denetim 3: 2D Optimizasyon/
Derinlik
Gen/
13 cm
Gen/
5 cm
Pen/
5 cm
Denetim 4: Sektör Genişliği/THI Yok Yok/
Kapalı
Orta/
Açık
Denetim 5: Renk Optimizasyonu/
PRF
Düşük/
273 Hz
Yüksek/
2841 Hz
Yüksek/
3571 Hz
Denetim 6: Renkli Kutu Konumu/
Boyutu
Def/Dar Alt/
Küçük
Def/Dar
Tablo 12: Dönüştürücü Modeli: rP19xp İşletim Modu: PW Doppler
İndeks Etiketi M. I.
TIS TIB
TIC
Tarama
Taramasız
Taramasız
A
aprt
1 A
aprt
>1
Global Maksimum İndeks Değeri 1,5 1,9 4,0 3,2
İlişkili Akustik
Parametre
p
r.3
(MPa) 2,17
W
0
(mW) 192,5 211,8
minimum [W
.3
(z
1
),
I
TA.3
(z
1
)]
(mW) 108,3
z
1
(cm) 1,9
Z
bp
(cm) 2,5
Z
sp
(cm) 5,10
z@PII
.3maks
0,5
d
eq
(z
sp
) (cm) 0,60
F
c
(MHz) 2,08 3,69 2,06 2,04
A
aprt
boyutları X (cm) 1,92 1,92 1,92
Y (cm) 1,15 1,15 1,15
Veriler bu dönüştürücü/mod için uygulanabilir değildir.
Tablo 11: Dönüştürücü Modeli: rP19xp İşletim Modu: Renkli/CPD
İndeks Etiketi M. I.
TIS TIB
TIC
Tarama
Taramasız
Taramasız
A
aprt
1 A
aprt
>1
Veriler bu dönüştürücü/mod için uygulanabilir değildir.
Dansk Norsk Svenska Ελληνικά Русский rkçe
Akustik çıktı 205
Diğer Bilgiler
PD (μsaniye) 1,141
PRF (Hz) 1562
p
r
@PII
maks
(MPa) 2,24
d
eq
@Pll
maks
(cm) 0,54
Fokal Uzunluk FL
x
(cm) 11,51 11,51
FL
y
(cm) 9,00 9,00
I
PA.3
@MI
maks
(W/cm
2
)
156
Çalıştırma
Denetim
Koşulları
Denetim 1: Muayene Türü Abd Crd Abd Abd
Denetim 2: Örnek Hacmi Boyutu 1 mm 7 mm 1 mm 1 mm
Denetim 3: Örnek Hacmi Konumu Bölge 0
(13 mm)
Bölge 7
(115 mm)
Bölge 6
(96 mm)
Bölge 7
(115 mm)
Denetim 4: PRF 1562 Hz 1008 Hz 1562 Hz 1562 Hz
Denetim 5: TDI Kapalı ık Kapalı Kapalı
Tablo 12: Dönüştürücü Modeli: rP19xp İşletim Modu: PW Doppler
İndeks Etiketi M. I.
TIS TIB
TIC
Tarama
Taramasız
Taramasız
A
aprt
1 A
aprt
>1
Veriler bu dönüştürücü/mod için uygulanabilir değildir.
206 Akustik çıktı
Tablo 13: Dönüştürücü Modeli: rP19xp İşletim Modu: CW Doppler
İndeks Etiketi M. I.
TIS TIB
TIC
Tarama
Taramasız
Taramasız
A
aprt
1 A
aprt
>1
Global Maksimum İndeks Değeri (a) 1,2 4,0 3,1
İlişkili Akustik
Parametre
p
r.3
(MPa) #
W
0
(mW) 130,6 134,7 125,7
minimum [W
.3
(z
1
),
I
TA.3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm) 3,40
z@PII
.3maks
#
d
eq
(z
sp
) (cm) 0,47
F
c
(MHz) # 2,00 2,00 2,00
A
aprt
boyutları X (cm) 0,90 0,90 0,72
Y (cm) 1,15 1,15 1,15
Diğer Bilgiler
PD (μsaniye) #
PRF (Hz) #
p
r
@PII
maks
(MPa) #
d
eq
@Pll
maks
(cm) 0,47
Fokal Uzunluk FL
x
(cm) 22,01 1,30
FL
y
(cm) 9,00 9,00
I
PA.3
@MI
maks
(W/cm
2
)
#
Çalıştırma
Denetim
Koşulları
Denetim 1: Muayene Türü Crd Crd Crd
Denetim 2: Örnek Hacmi Konumu Bölge 11
(220 mm)
Bölge 10
(189 mm)
Bölge 0
(13 mm)
(a) Bu indeks bu işletim modu için gerekli değildir; değer <1'dir.
# Aşağıda belirtilen nedenle global maksimum indeks değeri raporlanmamış olduğundan bu çalıştırma koşulu için
herhangi bir veri raporlanmamıştır. (Referans Global Maksimum İndeks Değeri çizgisi.)
Veriler bu dönüştürücü/mod için uygulanabilir değildir.
Dansk Norsk Svenska Ελληνικά Русский rkçe
Akustik çıktı 207
Tablo 14: Dönüştürücü Modeli: rP19xp (Orbital kullanım) İşletim Modu: 2D
İndeks Etiketi M. I.
TIS TIB
TIC
Tarama
Taramasız
Taramasız
A
aprt
1 A
aprt
>1
Global Maksimum İndeks Değeri 0,17 0,026 0,057
İlişkili Akustik
Parametre
p
r.3
(MPa) 0,26
W
0
(mW) 2,35 3,88
minimum [W
.3
(z
1
),
I
TA.3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm)
z@PII
.3maks
4,00
d
eq
(z
sp
) (cm)
F
c
(MHz) 2,34 2,33 2,34
A
aprt
boyutları X (cm) 1,92 1,92
Y (cm) 1,15 1,15
Diğer Bilgiler
PD (μsaniye) 0,59
PRF (Hz) 2317
p
r
@PII
maks
(MPa) 0,45
d
eq
@Pll
maks
(cm)
Fokal Uzunluk FL
x
(cm) 16,77 16,77
FL
y
(cm) 9,00 9,00
I
PA.3
@MI
maks
(W/cm
2
)
3,41
Çalıştırma
Denetim
Koşulları
Denetim 1: Muayene Türü Orb Orb Orb
Denetim 2: Optimizasyon Gen Gen Gen
Denetim 3: Derinlik 31 cm 31 cm 31 cm
Denetim 4: THI Kapalı Kapalı Kapalı
Veriler bu dönüştürücü/mod için uygulanabilir değildir.
208 Akustik çıktı
Tablo 15: Dönüştürücü Modeli: rP19xp (Orbital kullanım) İşletim Modu: M Mode
İndeks Etiketi M. I.
TIS TIB
TIC
Tarama
Taramasız
Taramasız
A
aprt
1 A
aprt
>1
Global Maksimum İndeks Değeri 0,17 0,025 0,012 0,055
İlişkili Akustik
Parametre
p
r.3
(MPa) 0,26
W
0
(mW) 1,848 0,84 3,68
minimum [W
.3
(z
1
),
I
TA.3
(z
1
)]
(mW) 0,41
z
1
(cm) 2,80
Z
bp
(cm) 2,52
Z
sp
(cm) 3,8
z@PII
.3maks
4,00
d
eq
(z
sp
) (cm) 0,85
F
c
(MHz) 2,34 2,37 2,37 2,34 2,37
A
aprt
boyutları X (cm) 1,92 1,92 1,92 1,92
Y (cm) 1,15 1,15 1,15 1,15
Diğer Bilgiler
PD (μsaniye) 0,59
PRF (Hz) 1600
p
r
@PII
maks
(MPa) 0,45
d
eq
@Pll
maks
(cm) 0,58
Fokal Uzunluk FL
x
(cm) 14,0 14,0 14,0
FL
y
(cm) 9,0 9,0 9,0
I
PA.3
@MI
maks
(W/cm
2
)
3,41
Çalıştırma
Denetim
Koşulları
Denetim 1: Muayene Türü Orb Orb Orb Orb
Denetim 2: Optimizasyon Gen Gen Gen Gen
Denetim 3: Derinlik 31 cm 25 cm 31 cm 25 cm
Denetim 4: THI Kapalı Kapalı Kapalı Kapalı
Veriler bu dönüştürücü/mod için uygulanabilir değildir.
Dansk Norsk Svenska Ελληνικά Русский rkçe
Akustik çıktı 209
Tablo 16: Dönüştürücü Modeli: rP19xp (Orbital kullanım) İşletim Modu: Renkli/CPD
İndeks Etiketi M. I.
TIS TIB
TIC
Tarama
Tara masız
Taramasız
A
aprt
1 A
aprt
>1
Global Maksimum İndeks Değeri 0,20 0,055 0,12
İlişkili Akustik
Parametre
p
r.3
(MPa) 0,28
W
0
(mW) 5,55 5,77
minimum [W
.3
(z
1
),
I
TA.3
(z
1
)]
(mW)
z
1
(cm)
Z
bp
(cm)
Z
sp
(cm)
z@PII
.3maks
0,4
d
eq
(z
sp
) (cm)
F
c
(MHz) 2,07 2,068 2,068
A
aprt
boyutları X (cm) 0,96 0,96
Y (cm) 1,15 1,15
Diğer Bilgiler
PD (μsaniye) 1,55
PRF (Hz) 6301
p
r
@PII
maks
(MPa) 0,29
d
eq
@Pll
maks
(cm)
Fokal Uzunluk FL
x
(cm) 1,3 1,3
FL
y
(cm) 9,0 9,0
I
PA.3
@MI
maks
(W/cm
2
)
2,58
Çalıştırma
Denetim
Koşulları
Denetim 1: Muayene Türü Orb Orb Orb
Denetim 2: Mod CVD CVD CVD
Denetim 3: 2D Optimizasyon/
Derinlik
Gen/5 cm Gen/
5
cm
Gen/
5cm
Denetim 4: Renk Optimizasyonu/
PRF
Med/
2778 Hz
Med/
2778 Hz
Med/
2778 Hz
Denetim 5: Renkli Kutu Konumu/
Boyutu
Varsayılan/
Üst
Varsayı-
lan/Üst
Varsayı-
lan/Üst
Veriler bu dönüştürücü/mod için uygulanabilir değildir.
210 Akustik çıktı
Tablo 17: Dönüştürücü Modeli: rP19xp (Orbital kullanım) İşletim Modu: PW Doppler
İndeks Etiketi M. I.
TIS TIB
TIC
Tarama
Taramasız
Taramasız
A
aprt
1 A
aprt
>1
Global Maksimum İndeks Değeri 0,19 0,22 0,56 0,51
İlişkili Akustik
Parametre
p
r.3
(MPa) 0,28
W
0
(mW) 33,8 34,4
minimum [W
.3
(z
1
),
I
TA.3
(z
1
)]
(mW) 21,89
z
1
(cm) 3,00
Z
bp
(cm) 2,52
Z
sp
(cm) 3,8
z@PII
.3maks
0,8
d
eq
(z
sp
) (cm) 0,79
F
c
(MHz) 2,11 2,09 2,09 2,09
A
aprt
boyutları X (cm) 1,92 1,92 1,92
Y (cm) 1,15 1,15 1,15
Diğer Bilgiler
PD (μsaniye) 3,67
PRF (Hz) 3906
p
r
@PII
maks
(MPa) 0,29
d
eq
@Pll
maks
(cm) 0,69
Fokal Uzunluk FL
x
(cm) 22,0 27,3
FL
y
(cm) 9,0 9,0
I
PA.3
@MI
maks
(W/cm
2
)
2,43
Çalıştırma
Denetim
Koşulları
Denetim 1: Muayene Türü Orb Orb Orb Orb
Denetim 2: Örnek Hacmi Boyutu 3 mm 9 mm 9 mm 7 mm
Denetim 3: Örnek Hacmi Konumu Bölge 1
(23 mm)
Bölge 11
(220 mm)
Bölge 11
(220 mm)
Bölge 13
(273 mm)
Denetim 4: PRF 3906 Hz 2604 Hz 2604 Hz 1953 Hz
Veriler bu dönüştürücü/mod için uygulanabilir değildir.
Dansk Norsk Svenska Ελληνικά Русский rkçe
211
SonoSite X-Porte rP19xp
............................................................................................................................................................. 211
................................................................................................................................................................................................... 211
................................................................................................................................................................................................... 212
...................................................................................................................................................... 213
.................................................................................................................................................. 214
.......................................................................................................................................................... 214
......................................................................................................................................................................... 214
...................................................................................................................................................... 215
MI TI ......................................................................................................................................................................... 215
................................................................................................................................................................................................... 216
................................................................................................................................................................................................... 217
SonoSite X-Porte rP19xp
212
FUJIFILM SonoSite
+1-877-657-8118
+1-425-951-1330
+1-425-951-6700
ffss-service@fujifilm.com
www.sonosite.com
+31 20 751 2020
+44 14 6234 1151
+33 1 8288 0702
+49 69 8088 4030
+39 02 9475 3655
+34 91 123 8451
+65 6380-5581
Dansk Norsk Svenska Ελληνικά Русский rkçe
213
1
M Mode
a
PW
b
CW
rP19xp CVD, CPD
CVD, Var
CVD, CPD
CVD, CPD
CVD, CPD
CVD, CPD
a
Var = CPD =
CVD =
b
PW TDI
rP19xp Using CIVCO Products
with FUJIFILM SonoSite Systems
CIVCO FUJIFILM SonoSite
214
2
a
SaniCloth AF3
b
rP19xp
3
PI-Spray II rP19xp
10
a
b
www.sonosite.com
3
a
Cidex rP19xp
25
o
C
45
Cidex OPA rP19xp
20
o
C
12
a
www.sonosite.com
rP19xp rP19xp
4
rP19xp
a
1.8 m
a
Dansk Norsk Svenska Ελληνικά Русский rkçe
215
MI TI
5 (MI)
rP19xp
MI
MI
6 (TI)
PRF
rP19xp
(PRF)
TI
TI
216
7 TI MI 1.0
2D/
M Mode
CPD/
PW CW
rP19xp MI
TIC TIB TIS
8 (°C )
rP19xp
15.8
8.8
Dansk Norsk Svenska Ελληνικά Русский rkçe
217
9 rP19xp
M.I.
TIS TIB
TIC
A
aprt
1 A
aprt
>1
1.5 1.2 2.9
p
r.3
(MPa) 1.95
W
0
(mW) 120.0 190.8
[W
.3
(z
1
), I
TA.3
(z
1
)]
(mW)
z
1
(cm)
z
bp
(cm)
z
sp
(cm)
z@PII
.3max
2.6
d
eq
(z
sp
) (cm)
F
c
(MHz) 1.72 2.02 1.80
A
aprt
X (cm) 1.92 1.92
Y (cm) 1.15 1.15
PD (μsec) 1.227
PRF (Hz) 2933
p
r
@PII
max
(MPa) 2.30
d
eq
@Pll
max
(cm)
FL
x
(cm) 3.42 3.42
FL
y
(cm) 9.00 9.00
I
PA.3
@MI
max
(W/cm
2
)
225
1
2
3
7 cm 5 cm 5 cm
4 THI
5
N/A N/A
- /
218
10 rP19xp M Mode
M.I.
TIS TIB
TIC
A
aprt
1 A
aprt
>1
1.5 1.1 0.9 3.0
p
r.3
(MPa) 1.95
W
0
(mW) 105 9.8 25.4 180.5
[W
.3
(z
1
), I
TA.3
(z
1
)]
(mW)
z
1
(cm)
z
bp
(cm)
z
sp
(cm) 3.02
z@PII
.3max
2.6
d
eq
(z
sp
) (cm) 0.444
F
c
(MHz) 1.72 2.09 2.09 1.732 1.75
A
aprt
X (cm) 1.92 0.78 1.02 1.92
Y (cm) 1.15 1.15 1.15 1.15
PD (μsec) 1.227
PRF (Hz) 2693
p
r
@PII
max
(MPa) 2.30
d
eq
@Pll
max
(cm) 0.427
FL
x
(cm) 4.56 4.56 2.25
FL
y
(cm) 9.00 9.00 9.00
I
PA.3
@MI
max
(W/cm
2
)
225
1
2
3
7 cm 7 cm 13 cm 5 cm
4 THI
- /
Dansk Norsk Svenska Ελληνικά Русский rkçe
219
11 rP19xp /
M.I.
TIS TIB
TIC
A
aprt
1 A
aprt
>1
1.5 1.6 3.8
p
r.3
(MPa) 2.15
W
0
(mW) 134.3 174.1
[W
.3
(z
1
), I
TA.3
(z
1
)]
(mW)
z
1
(cm)
z
bp
(cm)
z
sp
(cm)
z@PII
.3max
4.3
d
eq
(z
sp
) (cm)
F
c
(MHz) 2.05 2.60 2.09
A
aprt
X (cm) 1.34 0.63
Y (cm) 1.15 1.15
PD (μsec) 1.662
PRF (Hz) 1526
p
r
@PII
max
(MPa) 2.91
d
eq
@Pll
max
(cm)
FL
x
(cm) 4.56 2.25
FL
y
(cm) 9.00 9.00
I
PA.3
@MI
max
(W/cm
2
)
355
1
2
CVD CVD CVD
3 2D / /
13 cm
/
5 cm
/
5 cm
4 /THI
N/A
N/A/ /
5 / /
273 Hz
/
2841 Hz
/
3571 Hz
6 / / / /
- /
220
12 rP19xp
M.I.
TIS TIB
TIC
A
aprt
1 A
aprt
>1
1.5 1.9 4.0 3.2
p
r.3
(MPa) 2.17
W
0
(mW) 192.5 211.8
[W
.3
(z
1
), I
TA.3
(z
1
)]
(mW) 108.3
z
1
(cm) 1.9
z
bp
(cm) 2.5
z
sp
(cm) 5.10
z@PII
.3max
0.5
d
eq
(z
sp
) (cm) 0.60
F
c
(MHz) 2.08 3.69 2.06 2.04
A
aprt
X (cm) 1.92 1.92 1.92
Y (cm) 1.15 1.15 1.15
PD (μsec) 1.141
PRF (Hz) 1562
p
r
@PII
max
(MPa) 2.24
d
eq
@Pll
max
(cm) 0.54
FL
x
(cm) 11.51 11.51
FL
y
(cm) 9.00 9.00
I
PA.3
@MI
max
(W/cm
2
)
156
1
2
1 mm 7 mm 1 mm 1 mm
3 0
(13 mm)
7
(115 mm)
6
(96 mm)
7
(115 mm)
4 PRF
1562 Hz 1008 Hz 1562 Hz 1562 Hz
5 TDI
- /
Dansk Norsk Svenska Ελληνικά Русский rkçe
221
13 rP19xp
M.I.
TIS TIB
TIC
A
aprt
1 A
aprt
>1
(a) 1.2 4.0 3.1
p
r.3
(MPa) #
W
0
(mW) 130.6 134.7 125.7
[W
.3
(z
1
), I
TA.3
(z
1
)]
(mW)
z
1
(cm)
z
bp
(cm)
z
sp
(cm) 3.40
z@PII
.3max
#
d
eq
(z
sp
) (cm) 0.47
F
c
(MHz) # 2.00 2.00 2.00
A
aprt
X (cm) 0.90 0.90 0.72
Y (cm) 1.15 1.15 1.15
PD (μsec) #
PRF (Hz) #
p
r
@PII
max
(MPa) #
d
eq
@Pll
max
(cm) 0.47
FL
x
(cm) 22.01 1.30
FL
y
(cm) 9.00 9.00
I
PA.3
@MI
max
(W/cm
2
)
#
1
2 11
(220 mm)
10
(189 mm)
0
(13 mm)
(a) <1
#
- /
222
14 rP19xp
M.I.
TIS TIB
TIC
A
aprt
1 A
aprt
>1
0.17 0.026 0.057
p
r.3
(MPa) 0.26
W
0
(mW) 2.35 3.88
[W
.3
(z
1
), I
TA.3
(z
1
)]
(mW)
z
1
(cm)
z
bp
(cm)
z
sp
(cm)
z@PII
.3max
4.00
d
eq
(z
sp
) (cm)
F
c
(MHz) 2.34 2.33 2.34
A
aprt
X (cm) 1.92 1.92
Y (cm) 1.15 1.15
PD (μsec) 0.59
PRF (Hz) 2317
p
r
@PII
max
(MPa) 0.45
d
eq
@Pll
max
(cm)
FL
x
(cm) 16.77 16.77
FL
y
(cm) 9.00 9.00
I
PA.3
@MI
max
(W/cm
2
)
3.41
1
Orb Orb Orb
2
3
31 cm 31 cm 31 cm
4 THI
- /
Dansk Norsk Svenska Ελληνικά Русский rkçe
223
15 rP19xp M Mode
M.I.
TIS TIB
TIC
A
aprt
1 A
aprt
>1
0.17 0.025 0.012 0.055
p
r.3
(MPa) 0.26
W
0
(mW) 1.848 0.84 3.68
[W
.3
(z
1
), I
TA.3
(z
1
)]
(mW) 0.41
z
1
(cm) 2.80
z
bp
(cm) 2.52
z
sp
(cm) 3.8
z@PII
.3max
4.00
d
eq
(z
sp
) (cm) 0.85
F
c
(MHz) 2.34 2.37 2.37 2.34 2.37
A
aprt
X (cm) 1.92 1.92 1.92 1.92
Y (cm) 1.15 1.15 1.15 1.15
PD (μsec) 0.59
PRF (Hz) 1600
p
r
@PII
max
(MPa) 0.45
d
eq
@Pll
max
(cm) 0.58
FL
x
(cm) 14.0 14.0 14.0
FL
y
(cm) 9.0 9.0 9.0
I
PA.3
@MI
max
(W/cm
2
)
3.41
1
Orb Orb Orb Orb
2
3
31 cm 25 cm 31 cm 25 cm
4 THI
- /
224
16 rP19xp /
M.I.
TIS TIB
TIC
A
aprt
1 A
aprt
>1
0.20 0.055 0.12
p
r.3
(MPa) 0.28
W
0
(mW) 5.55 5.77
[W
.3
(z
1
), I
TA.3
(z
1
)]
(mW)
z
1
(cm)
z
bp
(cm)
z
sp
(cm)
z@PII
.3max
0.4
d
eq
(z
sp
) (cm)
F
c
(MHz) 2.07 2.068 2.068
A
aprt
X (cm) 0.96 0.96
Y (cm) 1.15 1.15
PD (μsec) 1.55
PRF (Hz) 6301
p
r
@PII
max
(MPa) 0.29
d
eq
@Pll
max
(cm)
FL
x
(cm) 1.3 1.3
FL
y
(cm) 9.0 9.0
I
PA.3
@MI
max
(W/cm
2
)
2.58
1
Orb Orb Orb
2
CVD CVD CVD
3 2D / Gen
/5 cm
Gen
/5 cm
Gen
/5 cm
4 / /
2778 Hz
/
2778 Hz
/
2778 Hz
5 / / / /
- /
Dansk Norsk Svenska Ελληνικά Русский rkçe
225
17 rP19xp
M.I.
TIS TIB
TIC
A
aprt
1 A
aprt
>1
0.19 0.22 0.56 0.51
p
r.3
(MPa) 0.28
W
0
(mW) 33.8 34.4
[W
.3
(z
1
), I
TA.3
(z
1
)]
(mW) 21.89
z
1
(cm) 3.00
z
bp
(cm) 2.52
z
sp
(cm) 3.8
z@PII
.3max
0.8
d
eq
(z
sp
) (cm) 0.79
F
c
(MHz) 2.11 2.09 2.09 2.09
A
aprt
X (cm) 1.92 1.92 1.92
Y (cm) 1.15 1.15 1.15
PD (μsec) 3.67
PRF (Hz) 3906
p
r
@PII
max
(MPa) 0.29
d
eq
@Pll
max
(cm) 0.69
FL
x
(cm) 22.0 27.3
FL
y
(cm) 9.0 9.0
I
PA.3
@MI
max
(W/cm
2
)
2.43
1
Orb Orb Orb Orb
2
3 mm 9 mm 9 mm 7 mm
3 1
(23 mm)
11
(220 mm)
11
(220 mm)
13
(273 mm)
4 PRF
3906 Hz 2604 Hz 2604 Hz 1953 Hz
- /
226
P23130-01
*P23130-01*
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210
  • Page 211 211
  • Page 212 212
  • Page 213 213
  • Page 214 214
  • Page 215 215
  • Page 216 216
  • Page 217 217
  • Page 218 218
  • Page 219 219
  • Page 220 220
  • Page 221 221
  • Page 222 222
  • Page 223 223
  • Page 224 224
  • Page 225 225
  • Page 226 226
  • Page 227 227
  • Page 228 228
  • Page 229 229
  • Page 230 230

Fujifilm SonoSite X-Porte User Manual Supplement

Type
User Manual Supplement