Dear Customer,
We appreciate this opportunity to service your flow measurement and control requirements with a Brooks
Instrument device. Every day, flow customers all over the world turn to Brooks Instrument for solutions to their
gas and liquid low-flow applications. Brooks provides an array of flow measurement and control products for
various industries from biopharmaceuticals, oil and gas, fuel cell research and chemicals, to medical devices,
analytical instrumentation, semiconductor manufacturing, and more.
The Brooks product you have just received is of the highest quality available, offering superior performance,
reliability and value to the user. It is designed with the ever changing process conditions, accuracy requirements
and hostile process environments in mind to provide you with a lifetime of dependable service.
We recommend that you read this manual in its entirety. Should you require any additional information concerning
Brooks products and services, please contact your local Brooks Sales and Service Office listed on the back cover
of this manual or visit www.BrooksInstrument.com
Yours sincerely,
Brooks Instrument
Installation and Operation Manual
X-VA-FC-eng
Part Number: 541B045AAG
December, 2015
Flow Controllers for Gas and Liquid Service
THIS PAGE WAS
INTENTIONALLY
LEFT BLANK
i
Contents
Installation and Operation Manual
X-VA-FC-eng
Part Number: 541B045AAG
December, 2015
Flow Controllers for Gas and Liquid Service
Paragraph Page
Number Number
Introduction Section 1
1-1 Description .....................................................................................................................................1-1
1-2 Design Features .............................................................................................................................1-1
1-3 Specifications .................................................................................................................................1-1
Installation Section 2
2-1 General ..........................................................................................................................................2-1
2-2 Receipt of Equipment .....................................................................................................................2-1
2-3 Recommended Storage Practice....................................................................................................2-1
2-4 Return Shipment ............................................................................................................................2-2
2-5 Transit Precautions.........................................................................................................................2-2
2-6 Removal from Storage....................................................................................................................2-2
2-7 Installation ......................................................................................................................................2-3
2-8 Panel Mounting...............................................................................................................................2-3
Operation Section 3
3-1 Operating Precaution......................................................................................................................3-1
3-2 General ..........................................................................................................................................3-1
Maintenance Section 4
4-1 General ..........................................................................................................................................4-1
Section A Essential Instructions
Essential Instructions......................................................................................................................A-1
Warranty, Local Sales/Service Contact Information ....................................................................... Back Cover
FIGURES
Figure Page
Number Number
1-1 Cutaway View, Principle of Operation .............................................................................................1-5
1-2 Cutaway View, NRS Valve ..............................................................................................................1-5
1-3 Cutaway View, cartridge Valve ........................................................................................................1-5
1-4 Dimensional Drawing Model FC 8744 ............................................................................................1-5
1-5 Dimensional Drawing Models FC 8802 and 8812 ...........................................................................1-6
1-6 Dimensional Drawing Models FC 8902 and 8912 ...........................................................................1-6
1-7 Dimensional Drawing Model FC 8842 ............................................................................................1-7
1-8 Dimensional Drawing Model FC 8942 ............................................................................................1-7
1-9 Dimensional Drawing Model FC 8845 ............................................................................................1-8
1-10 Dimensional Drawing Model FC 8945 ............................................................................................1-8
1-11 Dimensional Drawing Models FC 8805 and 8815 ...........................................................................1-9
1-12 Dimensional Drawing Models FC 8905 and 8915 ...........................................................................1-9
1-13 Dimensional Drawing Model FC 8830 ...........................................................................................1-10
TABLES
Table Page
Number Number
1-1 Flow Ranges ..................................................................................................................................1-3
1-2a Pressure/Temperature Ratings & Pressure Drop............................................................................1-3
1-2b Pressure/Temperature Ratings CRN ..............................................................................................1-3
1-3 Materials of Construction/ Connection/ Valve Option ......................................................................1-4
1-4 Model Code ...................................................................................................................................1-11
1-5 Sizing Chart ...................................................................................................................................1-13
ii
Contents
Installation and Operation Manual
X-VA-FC-eng
Part Number: 541B045AAG
December, 2015
Flow Controllers for Gas and Liquid Service
THIS PAGE WAS
INTENTIONALLY
LEFT BLANK
1-1
Section 1 Introduction
Installation and Operation Manual
X-VA-FC-eng
Part Number: 541B045AAG
December, 2015
Flow Controllers for Gas and Liquid Service
1-1 Description
Brooks
®
flow controllers are designed to maintain a constant differential
pressure across an integral, manual flow regulating valve. The incoming
fluid pressure on one side of the diaphragm, and outlet pressure plus
spring action on the other side, position an internal diaphragm-actuated
control valve. Variations in the supply or discharge pressure disturb the
balance of forces on the diaphragm, causing the internal control valve to
open or close, thus maintaining a fixed differential pressure across the
integral, manual flow regulating valve resulting in constant flow.
Refer to Figure 1-1.
Model FC 8744 controllers are used for accurately adjusting and
maintaining small gas and liquid flows with variable downstream pressures.
Series FC 8800 controllers are used for accurately adjusting and
maintaining liquid and gas flows with variable upstream pressures.
Series FC 8900 controllers are used for accurately adjusting and
maintaining liquid and gas flows with variable downstream pressures.
1-2 Design Features
Wide range of models for high and low flow rates.
Integral Controller with flowmeter assemblies in a compact size.
Brass or 316 Stainless Steel construction compatible with a wide range
of fluids.
Front or Rear Panel Mounting options.
15 Turn NRS
TM
(extremely low flow) valve option for more precise
control.
1-3 Specifications
Flow Ranges
Water - up to 480 GPH / 1820 l/h
Air - up to 2130 SCFH / 56000 l
n
/h
Refer to Table 1-1.
Pressure and Temperature Ratings
Up to 1000 psig / 69 bar.
Refer to Table 1-2a or 1-2b.
Minimum Operating Temperature: -40°F/C.
Maximum Operating Temperature: Refer to Tables 2a or 2b.
1-2
Section 1 Introduction
Installation and Operation Manual
X-VA-FC-eng
Part Number: 541B045AAG
December, 2015
Flow Controllers for Gas and Liquid Service
Pressure Equipment Directive (97/23/EC)
Equipment falls under Sound Engineering Practice (SEP) according to the
directive.
Pressure Drop
Refer to Table 1-2a.
Materials of Construction Controller Body:
316 Stainless Steel, Brass or Aluminum (FC 8744 only).
Refer to Table 1-3.
Controller Diaphragm:
Buna-N, Teflon
®
or Viton
®
fluoroelastomers
Refer to Table 1-3.
Needle Valve:
1) 316 Stainless Steel Cartridge valve, Refer to Figure 1-3,
Refer to DS-VA-CART-eng
2) 316 Stainless Steel NRS Valve, Refer to Figure 1-2,
Refer to DS-VA-8503-eng
3) 316 Stainless Steel standard needle valve type
Refer to Table 1-3.
O-rings:
Viton fluoroelastomers
Buna-N
Kalrez
®
(SS body only)
EPR (SS body only)
Kalrez
®
/Teflon
®
(SS body only)
Refer to Table 1-3.
Meter Dimensions
Refer to Figures 1-2 thru 1-11.
Sizing
Refer to Table 1-5.
Material Certification: (Stainless Steel body only)
Certification to NACE MR-01-75
Certification to DIN 50049-2.2
Certification to DIN 50049-3.1
Ordering Information and Model Codes
Refer to Table 1-4.
1-3
Section 1 Introduction
Installation and Operation Manual
X-VA-FC-eng
Part Number: 541B045AAG
December, 2015
Flow Controllers for Gas and Liquid Service
Table 1-1 Flow Ranges
Table 1-2a Pressure/Temperature Ratings and Pressure Drop
Table 1-2b Pressure/Temperature Ratings CRN
1-4
Section 1 Introduction
Installation and Operation Manual
X-VA-FC-eng
Part Number: 541B045AAG
December, 2015
Flow Controllers for Gas and Liquid Service
Table 1-3 Materials of Construction / Connection / Valve Option
Figure 1-1 Cutaway View, Principle of Operation
Figure 1-3 Cutaway View, Cartridge ValveFigure 1-2 Cutaway View, NRS Valve
Model
Item 00 02 05 12 15 40 42 45 FC 8830 FC 8744
Body/Diaphragm/Valve Seat & O-ring
Brass/Viton X X - X - X X - - -
Brass/Buna/Buna-N X X - X - X X - - -
SS/Teflon XXXXXXXXX -
SS/Viton X X - X - X X - X -
A
lum/Buna-N ---------X
Connection Size and Type
1/4" F-NPT XXXXXXXX - -
1/8" F-NPT XXX- -XXX-X
1/8" Tube Compression X X X - - X X X - X
1/4" Tube Compression XXXXXXXX - -
1/4" I.D. Hose X X - X - X X - - X
3/4" F-NPT --------X-
Integral 5/16-24 UNF Thd ---------X
Integral connection for 1350/55 - one end X - - - - X - - - -
Filter
Filter - inlet XXXXXXXX-X
Filter - inlet & outlet ---------X
V
alve Type
Cartridge valve XXX-------
NRS Valve -----XXX-X
Digital handle NRS Valve -----XXX-X
High Flow Needle Valve ---XX---X-
No Valve XXX- -XXX-X
1-5
Section 1 Introduction
Installation and Operation Manual
X-VA-FC-eng
Part Number: 541B045AAG
December, 2015
Flow Controllers for Gas and Liquid Service
Figure 1-5 Dimensional Drawing Models FC 8802 and 8812
Figure 1-4 Dimensional Drawing Model FC 8744
1-6
Section 1 Introduction
Installation and Operation Manual
X-VA-FC-eng
Part Number: 541B045AAG
December, 2015
Flow Controllers for Gas and Liquid Service
Figure 1-7 Dimensional Drawing Model FC 8842
Figure 1-6 Dimensional Drawing Models FC 8902 and 8912
1-7
Section 1 Introduction
Installation and Operation Manual
X-VA-FC-eng
Part Number: 541B045AAG
December, 2015
Flow Controllers for Gas and Liquid Service
Figure 1-9 Dimensional Drawing Model FC 8845
Figure 1-8 Dimensional Drawing Model FC 8942
1-8
Section 1 Introduction
Installation and Operation Manual
X-VA-FC-eng
Part Number: 541B045AAG
December, 2015
Flow Controllers for Gas and Liquid Service
Figure 1-11 Dimensional Drawing Models FC 8805 and 8815
Figure 1-10 Dimensional Drawing Model FC 8945
1-9
Section 1 Introduction
Installation and Operation Manual
X-VA-FC-eng
Part Number: 541B045AAG
December, 2015
Flow Controllers for Gas and Liquid Service
Figure 1-13 Dimensional Drawing Model FC 8830
Figure 1-12 Dimensional Drawing Models FC 8905 and 8915
1-10
Section 1 Introduction
Installation and Operation Manual
X-VA-FC-eng
Part Number: 541B045AAG
December, 2015
Flow Controllers for Gas and Liquid Service
Table 1-4 Model Code
1-11
Section 1 Introduction
Installation and Operation Manual
X-VA-FC-eng
Part Number: 541B045AAG
December, 2015
Flow Controllers for Gas and Liquid Service
Table 1-4 Model Code Cont’d
1-12
Section 1 Introduction
Installation and Operation Manual
X-VA-FC-eng
Part Number: 541B045AAG
December, 2015
Flow Controllers for Gas and Liquid Service
Table 1-5 Sizing Chart
2-1
Section 2 InstallationInstallation and Operation Manual
X-VA-FC-eng
Part Number: 541B045AAG
December, 2015
Flow Controllers for Gas and Liquid Service
2-1 General
This section contains the procedures for the receipt and installation of the
instrument. Do not attempt to start the system until the instrument has
been permanently installed. It is extremely important that the start-up
procedures be followed in the exact sequence presented.
2-2 Receipt of Equipment
When the instrument is received, the outside packing case should be
checked for damage incurred during shipment. If the packing case is
damaged, the local carrier should be notified at once regarding his liability.
A report should be submitted to your nearest Product Service Department.
Brooks Instrument
407 W. Vine Street
P.O. Box 903
Hatfield, PA 19440 USA
Toll Free (888) 554 FLOW (3569)
Tel (215) 362 3700
Fax (215) 362 3745
E-mail: BrooksAm@BrooksInstrument.com
www.BrooksInstrument.com
Brooks Instrument Brooks Instrument
Neonstraat 3 1-4-4 Kitasuna Koto-Ku
6718 WX Ede, Netherlands Tokyo, 136-0073 Japan
P.O. Box 428 Tel +81 (0) 3 5633 7100
6710 BK Ede, Netherlands Fax +81 (0) 3 5633 7101
Tel +31 (0) 318 549 300 Email: BrooksAs@BrooksInstrument.com
Fax +31 (0) 318 549 309
E-mail: BrooksEu@BrooksInstrument.com
Remove the envelope containing the packing list. Outside of your clean area,
carefully remove the equipment from the packing case. Make sure spare
parts are not discarded with the packing material. Inspect for damaged or
missing parts.
2-3 Recommended Storage Practice
If intermediate or long-term storage of equipment is required, it is
recommended that the equipment be stored in accordance with the
following:
a. Within the original shipping container.
b. Stored in a sheltered area, preferably a warm, dry, heated warehouse.
c. 32°C (90°F)maximum,45°F (7°C) minimum.
d. Relative humidity 45% nominal, 60% maximum, 25% minimum.
Upon removal from storage a visual inspection should be
conducted to verify the condition of equipment is "as received".
2-2
Section 2 Installation Installation and Operation Manual
X-VA-FC-eng
Part Number: 541B045AAG
December, 2015
Flow Controllers for Gas and Liquid Service
2-4 Return Shipment
Prior to returning any instrument to the factory visit the Brooks website
www.BrooksInstrument.com for a Return Materials Authorization Number
(RMA#), or contact one of the following locations:
Brooks Instrument
407 W. Vine Street
P.O. Box 903
Hatfield, PA 19440 USA
Toll Free (888) 554 FLOW (3569)
Tel (215) 362 3700
Fax (215) 362 3745
E-mail: BrooksAm@BrooksInstrument.com
www.BrooksInstrument.com
Brooks Instrument Brooks Instrument
Neonstraat 3 1-4-4 Kitasuna Koto-Ku
6718 WX Ede, Netherlands Tokyo, 136-0073 Japan
P.O. Box 428 Tel +81 (0) 3 5633 7100
6710 BK Ede, Netherlands Fax +81 (0) 3 5633 7101
Tel +31 (0) 318 549 300 Email: BrooksAs@BrooksInstrument.com
Fax +31 (0) 318 549 309
E-mail: BrooksEu@BrooksInstrument.com
Instrument must have been purged in accordance with the following:
All flow instruments returned to Brooks requires completion of Form
RPR003-1, Brooks Instrument Decontamination Statement, along with a
Material Safety Data Sheet (MSDS) for the fluid(s) used in the instrument.
Failure to provide this information will delay processing by Brooks
personnel. Copies of these forms can be downloaded from the Brooks
website www.BrooksInstrument.com or are available from any Brooks
Instrument location listed above.
2-5 Transit Precautions
To safeguard against damage during transit, transport the instrument to the
installation site in the same container used for transportation from the
factory if circumstances permit.
2-6 Removal from Storage
Upon removal from storage, a visual inspection should be conducted to
verify the condition of the equipment is “as received.” If the equipment has
been in storage in conditions in excess of those recommended
(See Section 2-3), the device should be subjected to a pneumatic pressure
test in accordance with applicable vessel codes.
2-3
Section 2 InstallationInstallation and Operation Manual
X-VA-FC-eng
Part Number: 541B045AAG
December, 2015
Flow Controllers for Gas and Liquid Service
2-7 Installation
The inlet and outlet connections are identified by the terms “in” and “out”. The
controller may be installed in any attitude. Care must be exercised to prevent
solids from entering the controller. The internal flow area is very small and
any foreign material entering the controller will impair the operation of the
needle valve and controller. Inlet and outlet filters should be installed. Optional
integral micron filter is available for all models except Model FC 8830
2-8 Panel Mounting
Series FC 8800 and FC 8900: Optional Mounting Brackets are provided
for panel mounting the controller. The brackets are rotatable and adjustable
to any desired location. For front panel mounting, two (2) 11/32" diameter
and one (1) 21/32" diameter panel openings are required.
To front panel mount controller, remove valve knob, valve bonnet and one
panel nut (for panel thickness over 1/4" remove both panel nuts). Place the
valve stem through the panel opening, install and tighten two mounting
nuts. Tighten mounting nuts and valve bonnet. Replace and tighten valve
knob.
Model FC 8744: Panel mounting nuts are provided on the valve stem for a
17/32" diameter panel cutout. The controller may be mounted in any
desired attitude. To panel mount the controller, remove the valve knob,
valve bonnet and one panel nut (for the panel thickness of 1/4" remove
both panel nuts). Place the valve stem through the panel opening and
tighten panel mounting nuts and valve bonnet. replace and tighten valve
knob.
.
2-4
Section 2 Installation Installation and Operation Manual
X-VA-FC-eng
Part Number: 541B045AAG
December, 2015
Flow Controllers for Gas and Liquid Service
THIS PAGE WAS
INTENTIONALLY
LEFT BLANK
3-1
Section 3 OperationInstallation and Operation Manual
X-VA-FC-eng
Part Number: 541B045AAG
December, 2015
Flow Controllers for Gas and Liquid Service
3-1 Operating Precaution
3-2 General
Series FC 8800: After the flow controller is installed and the downstream
condition established, adjust the upstream pressure to the value required
to pass the maximum flow rate desired with the integral valve 90% open. If
a flow meter is used it should be installed downstream of the controller
where the pressure is constant. Do not attempt to use the valve for shut-
off. If tight shut-off is required a separate on-off valve should be installed
upstream of the controller. Should the downstream condition change, thus
changing the pressure, a proportional change in flow rate will result.
Model FC 8744 & Series FC 8900: After the flow controller is installed and
the upstream condition established, adjust the downstream pressure to the
value required to pass maximum flow rate desired with integral valve 90%
open. A good pressure regulator should be installed upstream of the
controller. If the supply or upstream pressure varies, the flow rate will vary
proportionally. If a flow meter is used for rate indication, install it on the
constant pressure or upstream side of the controller. Use a separate valve
for tight shut-off, if required.
3-2
Section 3 Operation
Installation and Operation Manual
X-VA-FC-eng
Part Number: 541B045AAG
December, 2015
Flow Controllers for Gas and Liquid Service
THIS PAGE WAS
INTENTIONALLY
LEFT BLANK
4-1
Section 4 Maintenance
Installation and Operation Manual
X-VA-FC-eng
Part Number: 541B045AAG
December, 2015
Flow Controllers for Gas and Liquid Service
4-1 Maintenance
The FC Series Flow Controllers require no maintenance when installed in a
dirt-free flow line. Repair or disassembly of the regulator in the field is not
recommended. The regulator parts are ultrasonically cleaned and white-
room assembled for trouble free operation. Do not attempt to clean the
regulator by flushing with solvent or air.
The optional filter elements should be periodically inspected and
ultrasonically cleaned or replaced if necessary. When reinstalling the filter
elements use care to prevent any dirt or foreign matter from entering the
lines.
Should the regulator become inoperative, it should be returned to the
factory for repair or replacement.
4-2
Section 4 Maintenance
Installation and Operation Manual
X-VA-FC-eng
Part Number: 541B045AAG
December, 2015
Flow Controllers for Gas and Liquid Service
THIS PAGE WAS
INTENTIONALLY
LEFT BLANK
A-1
Section A - Essential Instructions
Installation and Operation Manual
X-VA-FC-eng
Part Number: 541B045AAG
December, 2015
Flow Controllers for Gas and Liquid Service
Ɉɫɧɨɜɧɢ ɢɧɫɬɪɭɤɰɢɢ
ɉɪɨɱɟɬɟɬɟ ɩɪɟɞɢ ɪɚɛɨɬɚ!
Brooks Instrument ɩɪɨɟɤɬɢɪɚ, ɩɪɨɢɡɜɟɠɞɚ ɢ ɬɟɫɬɜɚ ɩɪɨɞɭɤɬɢɬɟ ɫɢ ɩɨ ɬɚɤɴɜ ɧɚɱɢɧ, ɱɟ ɬɟ ɞɚ ɨɬɝɨɜɚɪɹɬ ɧɚ ɦɧɨɝɨɛɪɨɣɧɢ ɧɚɰɢɨɧɚɥɧɢ ɢ
ɦɟɠɞɭɧɚɪɨɞɧɢ ɫɬɚɧɞɚɪɬɢ. Ɍɟɡɢ ɨɛɨɪɭɞɜɚɧɢɹ ɬɪɹɛɜɚ ɩɪɚɜɢɥɧɨ ɞɚ ɫɟ ɢɧɫɬɚɥɢɪɚɬ, ɟɤɫɩɥɨɚɬɢɪɚɬ ɢ ɩɨɞɞɴɪɠɚɬ ɡɚ ɞɚ ɫɟ ɝɚɪɚɧɬɢɪɚ, ɱɟ ɳɟ ɦɨɝɚɬ
ɞɚ ɪɚɛɨɬɹɬ ɫɴɨɬɜɟɬɧɨ ɧɚ ɬɟɯɧɢɬɟ ɧɨɪɦɚɥɧɢ ɫɩɟɰɢɮɢɤɚɰɢɢ. ɋɥɟɞɜɚɳɢɬɟ ɢɧɫɬɪɭɤɰɢɢ ɬɪɹɛɜɚ ɞɚ ɫɟ ɫɩɚɡɜɚɬ ɢ
ɬɪɹɛɜɚ ɞɚ ɫɟ ɜɤɥɸɱɚɬ ɜ
ɩɪɨɝɪɚɦɚɬɚ ɡɚ ɛɟɡɨɩɚɫɧɨɫɬ ɧɚ ɬɪɭɞɚ ɩɪɢ ɢɧɫɬɚɥɢɪɚɧɟɬɨ, ɟɤɫɩɥɨɚɬɚɰɢɹɬɚ ɢ ɩɨɞɞɪɴɠɤɚɬɚ ɧɚ ɩɪɨɞɭɤɬɢɬɟ ɧɚ Brooks Instrument.
x Ɂɚ ɞɚ ɫɟ ɝɚɪɚɧɬɢɪɚ ɯɚɪɚɤɬɟɪɧɚɬɚ ɩɪɨɢɡɜɨɞɢɬɟɥɧɨɫɬ, ɢɧɫɬɚɥɢɪɚɧɟɬɨ, ɟɤɫɩɥɨɚɬɚɰɢɹɬɚ, ɚɤɬɭɚɥɢɡɢɪɚɧɟɬɨ, ɩɪɨɝɪɚɦɢɪɚɧɟɬɨ ɢ ɩɨɞɞɪɴɠɤɚɬɚ
ɧɚ ɩɪɨɞɭɤɬɚ ɬɪɹɛɜɚ ɞɚ ɫɟ ɢɡɜɴɪɲɜɚɬ ɫɚɦɨ ɨɬ ɤɜɚɥɢɮɢɰɢɪɚɧ ɩɟɪɫɨɧɚɥ.
x ɉɪɨɱɟɬɟɬɟ ɜɫɢɱɤɢ ɢɧɫɬɪɭɤɰɢɢ ɩɪɟɞɢ ɢɧɫɬɚɥɢɪɚɧɟɬɨ, ɟɤɫɩɥɨɚɬɚɰɢɹɬɚ ɢ ɩɨɞɞɪɴɠɤɚɬɚ ɧɚ
ɩɪɨɞɭɤɬɚ. Ⱥɤɨ ɬɨɜɚ ɪɴɤɨɜɨɞɫɬɜɨ ɧɟ ɟ
ɫɴɨɬɜɟɬɫɬɜɚɳɨɬɨ ɢɡɞɚɧɢɟ, ɜɢɠɬɟ ɧɚ ɡɚɞɧɚɬɚ ɨɛɥɨɠɤɚ ɢɧɮɨɪɦɚɰɢɹɬɚ ɡɚ ɤɨɧɬɚɤɬ ɫ ɦɟɫɬɧɢɹ ɬɴɪɝɨɜɫɤɢ ɨɮɢɫ. Ɂɚɩɚɡɟɬɟ ɬɨɜɚ ɪɴɤɨɜɨɞɫɬɜɨ
ɡɚ ɩɨ-ɤɴɫɧɨ ɢɧɮɨɪɦɢɪɚɧɟ.
ȼɇɂɆȺɇɂȿ: ɇɟ ɪɚɛɨɬɟɬɟ ɫ ɨɛɨɪɭɞɜɚɧɟɬɨ ɢɡɜɴɧ ɞɢɚɩɚɡɨɧɢɬɟ, ɭɤɚɡɚɧɢ ɜ ɢɧɫɬɪɭɤɰɢɹɬɚ ɢ ɪɴɤɨɜɨɞɫɬɜɨɬɨ ɩɨ ɟɤɫɩɥɨɚɬɚɰɢɹ.
ɇɟɢɡɩɴɥɧɟɧɢɟɬɨ ɧɚ ɬɨɜɚ ɦɨɠɟ ɞɚ ɞɨɜɟɞɟ ɞɨ ɫɟɪɢɨɡɧɢ ɬɟɥɟɫɧɢ ɩɨɜɪɟɞɢ ɢ / ɢɥɢ ɩɨɜɪɟɠɞɚɧɟ ɧɚ ɨɛɨɪɭɞɜɚɧɟɬɨ.
x Ⱥɤɨ ɧɟ ɪɚɡɛɢɪɚɬɟ ɧɹɤɨɢ ɢɧɫɬɪɭɤɰɢɢɬɟ, ɫɜɴɪɠɟɬɟ ɫɟ ɫ ɩɪɟɞɫɬɚɜɢɬɟɥɹ ɧɚ Brooks Instrument ɡɚ ɢɡɹɫɧɹɜɚɧɟ ɧɚ ɩɪɨɛɥɟɦɚ.
x ɋɩɚɡɜɚɣɬɟ ɜɫɢɱɤɢ ɩɪɟɞɭɩɪɟɠɞɟɧɢɹ, ɩɪɢɡɨɜɢ ɢ ɢɧɫɬɪɭɤɰɢɢ
ɨɡɧɚɱɟɧɢ ɜɴɪɯɭ ɨɛɨɪɭɞɜɚɧɟɬɨ ɢɥɢ ɞɨɫɬɚɜɟɧɢ ɡɚɟɞɧɨ ɫ ɧɟɝɨ.
x ɂɧɫɬɚɥɢɪɚɣɬɟ ɨɛɨɪɭɞɜɚɧɟɬɨ ɫɴɨɬɜɟɬɧɨ ɧɚ ɭɤɚɡɚɧɢɹɬɚ ɜ ɢɧɫɬɪɭɤɰɢɹɬɚ ɡɚ ɢɧɫɬɚɥɢɪɚɧɟ ɢ ɧɚ ɞɟɣɫɬɜɚɳɢɬɟ ɧɚ ɦɟɫɬɧɢ ɢ ɧɚɰɢɨɧɚɥɧɢ
ɩɪɟɞɩɢɫɚɧɢɹ. ɋɜɴɪɡɜɚɣɬɟ ɩɪɨɞɭɤɬɢɬɟ ɫɚɦɨ ɤɴɦ ɩɨɞɯɨɞɹɳɢ ɢɡɬɨɱɧɢɰɢ ɧɚ ɟɥɟɤɬɪɢɱɟɫɬɜɨ ɢ ɧɚɥɹɝɚɧɟ.
x ɏɨɞ: (1) Ȼɚɜɧɨ ɜɴɜɟɞɟɬɟ ɫɢɫɬɟɦɚɬɚ ɩɨɞ ɧɚɥɹɝɚɧɟ. Ȼɚɜɧɨ ɨɬɜɨɪɟɬɟ ɪɚɛɨɬɧɢɬɟ ɤɥɚɩɚɧɢ ɡɚ ɞɚ ɫɟ
ɢɡɛɟɝɧɚɬ ɤɨɥɟɛɚɧɢɹɬɚ ɧɚ ɩɨɬɨɤɚ. (2)
ɉɪɨɜɟɪɟɬɟ ɞɚɥɢ ɧɹɦɚ ɢɡɬɢɱɚɧɟ ɩɪɢ ɜɯɨɞɧɨɬɨ ɢ ɢɡɯɨɞɧɨɬɨ ɫɴɟɞɢɧɟɧɢɟ ɧɚ ɪɚɡɯɨɞɨɦɟɪɚ. Ⱥɤɨ ɧɹɦɚ ɢɡɬɢɱɚɧɟ, ɧɚɩɴɥɧɟɬɟ ɫɢɫɬɟɦɚɬɚ ɞɨ
ɪɚɛɨɬɧɨ ɧɚɥɹɝɚɧɟ.
x ɉɪɟɞɢ ɢɡɜɴɪɲɜɚɧɟ ɧɚ ɩɨɞɞɪɴɠɤɚɬɚ ɧɟɩɪɟɦɟɧɧɨ ɩɪɨɜɟɪɟɬɟ ɞɚɥɢ ɪɚɛɨɬɧɢɹɬ ɬɪɴɛɨɩɪɨɜɨɞ ɧɟ ɫɟ ɧɚɦɢɪɚ ɩɨɞ ɧɚɥɹɝɚɧɟ. Ⱥɤɨ ɫɚ ɧɟɨɛɯɨɞɢɦɢ
ɪɟɡɟɪɜɧɢ ɱɚɫɬɢ, ɫ ɨɩɪɟɞɟɥɟɧɢɬɟ ɨɬ Brooks Instrument ɪɟɡɟɪɜɧɢ ɱɚɫɬɢ ɬɪɹɛɜɚ ɞɚ ɛɨɪɚɜɢ
ɫɚɦɨ ɤɜɚɥɢɮɢɰɢɪɚɧ ɩɟɪɫɨɧɚɥ. ɇɟɪɚɡɪɟɲɟɧɢɬɟ
ɱɚɫɬɢ ɢ ɩɪɨɰɟɞɭɪɢ ɦɨɝɚɬ ɞɚ ɨɤɚɠɚɬ ɜɥɢɹɧɢɟ ɜɴɪɯɭ ɪɚɛɨɬɚɬɚ ɧɚ ɩɪɨɞɭɤɬɚ, ɢ ɫɴɳɨ ɞɚ ɡɚɫɬɪɚɲɚɬ ɛɟɡɨɩɚɫɧɨɫɬɬɚ ɧɚ ɟɤɫɩɥɨɚɬɚɰɢɹɬɚ.
Ɂɚɦɟɫɬɜɚɧɟɬɨ ɫ ɧɟɨɪɢɝɢɧɚɥɧɢ ɱɚɫɬɢ ɦɨɠɟ ɞɚ ɞɨɜɟɞɟ ɞɨ ɩɨɠɚɪ, ɨɩɚɫɧɨɫɬ ɨɬ ɬɨɤɨɜ ɭɞɚɪ ɢɥɢ ɧɟɩɪɚɜɢɥɧɚ ɪɚɛɨɬɚ.
x ȼɫɢɱɤɢ ɜɪɚɬɢ ɧɚ ɨɛɨɪɭɞɜɚɧɟɬɨ ɧɟɩɪɟɦɟɧɧɨ ɞɚ ɛɴɞɚɬ ɡɚɬɜɨɪɟɧɢ, ɚ ɡɚɳɢɬɧɢɬɟ ɩɨɤɪɢɬɢɹ
ɞɚ ɛɴɞɚɬ ɧɚ ɦɹɫɬɨɬɨ ɫɢ, ɡɚ ɞɚ ɫɟ ɢɡɛɟɝɧɚɬ
ɬɨɤɨɜɢɬɟ ɭɞɚɪɢ ɢ ɬɟɥɟɫɧɢɬɟ ɩɨɜɪɟɞɢ, ɨɫɜɟɧ ɚɤɨ ɤɜɚɥɢɮɢɰɢɪɚɧɢ ɫɩɟɰɢɚɥɢɫɬɢ ɢɡɜɴɪɲɜɚɬ ɪɚɛɨɬɢ ɩɨ ɧɟɝɨɜɨɬɨ ɩɨɞɞɴɪɠɚɧɟ.
ȼɇɂɆȺɇɂȿ: ɉɪɢ ɨɛɨɪɭɞɜɚɧɢɹɬɚ ɫ ɩɪɨɬɢɱɚɳɢ ɬɟɱɧɨɫɬɢ, ɚɤɨ ɩɨ ɧɹɤɚɤɜɚ ɩɪɢɱɢɧɚ ɟ ɧɟɨɛɯɨɞɢɦɨ ɞɚ ɫɟ ɡɚɬɜɨɪɹɬ ɧɚɦɢɪɚɳɢɬɟ ɫɟ ɞɨ
ɨɛɨɪɭɞɜɚɧɟɬɨ ɢɡɯɨɞɧɢ ɢ ɜɯɨɞɧɢ ɤɥɚɩɚɧɢ, ɨɛɨɪɭɞɜɚɧɟɬɨ ɬɪɹɛɜɚ ɧɚɩɴɥɧɨ ɞɚ ɫɟ ɢɡɩɪɚɡɧɢ. ɇɟɢɡɩɴɥɧɟɧɢɟɬɨ ɧɚ ɬɨɜɚ ɦɨɠɟ ɞɚ ɩɪɢɱɢɧɢ
ɬɨɩɥɢɧɧɨ ɪɚɡɲɢɪɟɧɢɟ ɧɚ ɬɟɱɧɨɫɬɬɚ, ɤɨɟɬɨ ɦɨɠɟ ɞɨ ɫɩɭɤɚ ɨɛɨɪɭɞɜɚɧɟɬɨ ɢ ɞɚ ɞɨɜɟɞɟ ɞɨ ɬɟɥɟɫɧɢ ɩɨɜɪɟɞɢ.
ȿɜɪɨɩɟɣɫɤɚ ɞɢɪɟɤɬɢɜɚ ɡɚ ɭɪɟɞɢ ɩɨɞ ɧɚɥɹɝɚɧɟ (PED)
ȼɫɢɱɤɢ ɫɴɨɪɴɠɟɧɢɹ ɩɨɞ ɧɚɥɹɝɚɧɟ ɫ ɜɴɬɪɟɲɧɨ ɧɚɥɹɝɚɧɟ ɧɚɞ 0,5 bar (g) ɢ ɫ ɪɚɡɦɟɪ ɩɨ-ɝɨɥɹɦ ɨɬ 25 mm ɢɥɢ 1" (ɢɧɱ), ɩɨɩɚɞɚɬ ɩɨɞ ɞɟɣɫɬɜɢɟɬɨ ɧɚ
ɟɜɪɨɩɟɣɫɤɚɬɚ ɞɢɪɟɤɬɢɜɚ ɡɚ ɭɪɟɞɢ ɩɨɞ ɧɚɥɹɝɚɧɟ (PED).
x ȽɥɚɜɚɌɟɯɧɢɱɟɫɤɢ ɞɚɧɧɢɧɚ ɧɚɫɬɨɹɳɨɬɨ ɪɴɤɨɜɨɞɫɬɜɨ ɫɴɞɴɪɠɚ ɫɜɴɪɡɚɧɢɬɟ ɫ ɞɢɪɟɤɬɢɜɚɬɚ PED ɢɧɫɬɪɭɤɰɢɢ.
x ɍɤɚɡɚɧɢɬɟ ɜ ɧɚɫɬɨɹɳɨɬɨ ɪɴɤɨɜɨɞɫɬɜɨ ɢɡɦɟɪɢɬɟɥɧɢ ɭɪɟɞɢ ɫɴɨɬɜɟɬɫɬɜɚɬ ɧɚ ɟɜɪɨɩɟɣɫɤɚɬɚ ɞɢɪɟɤɬɢɜɚ 97/23/ȿɈ.
x
ȼɫɢɱɤɢ ɪɚɡɯɨɞɨɦɟɪɢ ɧɚ Brooks Instrument ɫɟ ɨɬɧɚɫɹɬ ɤɴɦ ɮɥɭɢɞɢ ɨɬ ɝɪɭɩɚ 1.
x ɂɡɦɟɪɢɬɟɥɧɢɬɟ ɭɪɟɞɢ ɩɨ-ɝɨɥɟɦɢ ɨɬ 25 mm ɢɥɢ 1" (ɢɧɱ) ɫɴɨɬɜɟɬɫɬɜɚɬ ɧɚ I, II ɢɥɢ III ɤɚɬɟɝɨɪɢɹ ɫɩɨɪɟɞ PED.
x
ɂɡɦɟɪɢɬɟɥɧɢɬɟ ɭɪɟɞɢ ɫ ɪɚɡɦɟɪɢ 25 mm ɢɥɢ 1" (ɢɧɱ), ɢɥɢ ɩɨ-ɦɚɥɤɢ, ɫɥɟɞɜɚɬ ɞɨɛɪɚɬɚ ɢɧɠɟɧɟɪɧɚ ɩɪɚɤɬɢɤɚ (SEP).
ȿɜɪɨɩɟɣɫɤɚ ɞɢɪɟɤɬɢɜɚ ɡɚ ɟɥɟɤɬɪɨɦɚɝɧɢɬɧɚ ɫɴɜɦɟɫɬɢɦɨɫɬ (EMC)
ɇɨɫɟɳɨɬɨ ɡɧɚɤɚ ɋȿ (ɟɥɟɤɬɪɢɱɟɫɤɨ/ɟɥɟɤɬɪɨɧɧɨ) ɨɛɨɪɭɞɜɚɧɟ ɧɚ Brooks Instrument ɟ ɢɡɩɴɥɧɢɥɨ ɭɫɩɟɲɧɨ ɬɟɫɬɨɜɟɬɟ ɡɚ ɩɪɨɜɟɪɤɚ ɧɚ
ɢɡɢɫɤɜɚɧɢɹɬɚ ɡɚ ɟɥɟɤɬɪɨɦɚɝɧɢɬɧɚ ɫɴɜɦɟɫɬɢɦɨɫɬ (ɞɢɪɟɤɬɢɜɚ EMC 2004/108/EC).
Ɉɫɨɛɟɧɨ ɜɧɢɦɚɧɢɟ ɬɪɹɛɜɚ ɞɚ ɫɟ ɨɛɪɴɳɚ ɨɛɚɱɟ ɧɚ ɢɡɛɢɪɚɧɟɬɨ ɧɚ ɫɢɝɧɚɥɧɢɬɟ ɤɚɛɟɥɢ, ɢɡɩɨɥɡɜɚɧɢ ɫ ɨɛɨɪɭɞɜɚɧɟɬɨ, ɧɨɫɟɳɨ ɡɧɚɤɚ ɋȿ.
Ʉɚɱɟɫɬɜɨ ɧɚ ɫɢɝɧɚɥɧɢɬɟ ɤɚɛɟɥɢ, ɤɚɛɟɥɧɢɬɟ ɫɚɥɧɢɰɢ ɢ ɫɴɟɞɢɧɢɬɟɥɢ:
Brooks Insturment ɩɪɟɞɥɚɝɚ ɜɢɫɨɤɨɤɚɱɟɫɬɜɟɧɢ ɤɚɛɟɥɢ, ɨɬɝɨɜɚɪɹɳɢ ɧɚ ɢɡɢɫɤɜɚɧɢɹɬɚ ɧɚ CE ɫɟɪɬɢɮɢɤɚɰɢɹɬɚ.
Ⱥɤɨ ɢɡɩɨɥɡɜɚɬɟ ɫɨɛɫɬɜɟɧ ɫɢɝɧɚɥɟɧ ɤɚɛɟɥ, ɬɪɹɛɜɚ ɞɚ ɢɡɛɟɪɟɬɟ ɬɚɤɴɜ, ɤɨɣɬɨ ɟ ɧɚɩɴɥɧɨ ɡɚɳɢɬɟɧ ɫɴɫ 100%-ɨɜɨ ɟɤɪɚɧɢɪɚɧɟ.
ɋɴɟɞɢɧɢɬɟɥɢɬɟ ɬɢɩ „D” ɢɥɢɤɪɴɝɨɜɬɪɹɛɜɚ ɞɚ ɛɴɞɚɬ ɟɤɪɚɧɢɪɚɧɢ ɫ ɦɟɬɚɥɟɧ ɳɢɬ. ɉɪɢ ɧɟɨɛɯɨɞɢɦɨɫɬ ɡɚ ɮɢɤɫɢɪɚɧɟɬɨ ɧɚ ɳɢɬɚ ɧɚ ɤɚɛɟɥɚ
ɬɪɹɛɜɚ ɞɚ ɫɟ ɢɡɩɨɥɡɜɚɬ ɦɟɬɚɥɧɢ ɤɚɛɟɥɧɢ ɫɚɥɧɢɰɢ
.
ɓɢɬɴɬ ɧɚ ɤɚɛɟɥɚ ɬɪɹɛɜɚ ɞɚ ɫɟ ɫɜɴɪɠɟ ɫ ɦɟɬɚɥɧɨɬɨ ɩɨɤɪɢɬɢɟ ɢɥɢ ɦɟɬɚɥɧɢɹ ɫɚɥɧɢɤ ɢ ɜ ɞɜɚɬɚ ɤɪɚɹ ɞɚ ɫɟ ɟɤɪɚɧɢɪɚ ɜ 360°. ɓɢɬɴɬ ɬɪɹɛɜɚ ɞɚ
ɛɴɞɟ ɡɚɡɟɦɟɧ.
ɋɴɟɞɢɧɢɬɟɥɢɬɟ ɡɚ ɩɟɱɚɬɧɢ ɩɥɚɬɤɢ ɫɚ ɫɬɚɧɞɚɪɬɧɨ ɧɟɦɟɬɚɥɧɢ. ɂɡɩɨɥɡɜɚɧɢɬɟ ɤɚɛɟɥɢ ɬɪɹɛɜɚ ɞɚ ɛɴɞɚɬ ɡɚɳɢɬɟɧɢ ɫɴɫ 100%-ɨɜɨ ɟɤɪɚɧɢɪɚɧɟ, ɡɚ
ɞɚ ɨɬɝɨɜɚɪɹɬ ɧɚ CE ɫɟɪɬɢɮɢɤɚɰɢɹɬɚ.
ɓɢɬɴɬ ɬɪɹɛɜɚ ɞɚ
ɛɴɞɟ ɡɚɡɟɦɟɧ.
Ʉɨɧɮɢɝɭɪɚɰɢɹ ɧɚ ɤɨɧɬɚɤɬɢɬɟ: ȼɢɠ ɩɪɢɥɨɠɟɧɚɬɚ ɢɧɫɬɪɭɤɰɢɹ ɡɚ ɟɤɫɩɥɨɚɬɚɰɢɹ.
ȿɥɟɤɬɪɨɫɬɚɬɢɱɟɧ ɪɚɡɪɹɞ (ESD)
ȼɇɂɆȺɇɂȿ: ɉɪɢɛɨɪɴɬ ɫɴɞɴɪɠɚ ɟɥɟɤɬɪɨɧɧɢ ɤɨɦɩɨɧɟɧɬɢ, ɤɨɢɬɨ ɫɚ ɱɭɜɫɬɜɢɬɟɥɧɢ ɤɴɦ ɫɬɚɬɢɱɧɨɬɨ ɟɥɟɤɬɪɢɱɟɫɬɜɨ ɢ ɦɨɝɚɬ ɞɚ ɫɟ
ɩɨɜɪɟɞɹɬ ɨɬ ɧɟɝɨ. Ɍɪɹɛɜɚ ɞɚ ɫɟ ɫɩɚɡɜɚɬ ɫɴɨɬɜɟɬɧɢɬɟ ɩɪɨɰɟɞɭɪɢ ɩɨ ɜɪɟɦɟ ɧɚ ɢɡɜɚɠɞɚɧɟ, ɫɥɚɝɚɧɟ ɢɥɢ ɞɪɭɝɨ ɛɨɪɚɜɟɧɟ ɫ
ɜɴɬɪɟɲɧɢɬɟ ɦɨɧɬɚɠɧɢ ɩɥɚɬɤɢ ɢ ɭɫɬɪɨɣɫɬɜɚ.
ɉɪɨɰɟɞɭɪɚ ɡɚ ɪɚɛɨɬɚ:
1. ɂɡɤɥɸɱɟɬɟ ɨɛɨɪɭɞɜɚɧɟɬɨ.
2. ɉɟɪɫɨɧɚɥɴɬ ɬɪɹɛɜɚ ɞɚ ɫɟ ɡɚɡɟɦɢ ɫ
ɝɪɢɜɧɚ ɢɥɢ ɞɪɭɝɨ ɛɟɡɨɩɚɫɧɨ ɢ ɩɨɞɯɨɞɹɳɨ ɡɚ ɰɟɥɬɚ ɫɪɟɞɫɬɜɨ, ɩɪɟɞɢ ɞɚ ɢɧɫɬɚɥɢɪɚ, ɢɡɜɚɠɞɚ ɢɥɢ
ɪɟɝɭɥɢɪɚ ɦɨɧɬɚɠɧɚ ɩɥɚɬɤɚ ɢɥɢ ɞɪɭɝɨ ɜɴɬɪɟɲɧɨ ɭɫɬɪɨɣɫɬɜɨ.
3. ɉɟɱɚɬɧɢɬɟ ɦɨɧɬɚɠɧɢ ɩɥɚɬɤɢ ɬɪɹɛɜɚ ɞɚ ɫɟ ɬɪɚɧɫɩɨɪɬɢɪɚɬ ɜ ɩɪɨɜɨɞɹɳɚ ɨɩɚɤɨɜɤɚ. ɉɟɱɚɬɧɢɬɟ ɩɥɚɬɤɢ ɦɨɝɚɬ ɞɚ ɫɟ ɢɡɜɚɠɞɚɬ ɨɬ ɡɚɳɢɬɧɨɬɨ
ɩɨɤɪɢɬɢɟ ɫɚɦɨ ɧɟɩɨɫɪɟɞɫɬɜɟɧɨ ɩɪɟɞɢ ɢɧɫɬɚɥɢɪɚɧɟɬɨ. Ɉɬɫɬɪɚɧɟɧɢɬɟ ɩɟɱɚɬɧɢ ɩɥɚɬɤɢ ɧɟɡɚɛɚɜɧɨ ɬɪɹɛɜɚ ɞɚ
ɫɟ ɫɥɨɠɚɬ ɜ ɡɚɳɢɬɧɚ ɨɩɚɤɨɜɤɚ,
ɫɥɭɠɟɳɚ ɡɚ ɬɪɚɧɫɩɨɪɬɢɪɚɧɟ, ɫɤɥɚɞɢɪɚɧɟ ɢɥɢ ɜɪɴɳɚɧɟ ɧɚ ɩɪɨɢɡɜɨɞɢɬɟɥɹ.
Ɂɚɛɟɥɟɠɤɢ:
ɇɟ ɟ ɭɧɢɤɚɥɧɨ ɹɜɥɟɧɢɟ, ɱɟ ɬɨɡɢ ɩɪɢɛɨɪ ɫɴɞɴɪɠɚ ɱɭɜɫɬɜɢɬɟɥɧɢ ɤɴɦ ɟɥɟɤɬɪɨɫɬɚɬɢɱɧɢɹ ɡɚɪɹɞ (ESD) ɤɨɦɩɨɧɟɧɬɢ. Ȼɨɥɲɢɧɫɬɜɨɬɨ ɨɬ
ɫɴɜɪɟɦɟɧɧɢɬɟ ɟɥɟɤɬɪɨɧɧɢ ɩɪɢɛɨɪɢ ɫɴɞɴɪɠɚɬ ɤɨɦɩɨɧɟɧɬɢ, ɢɡɝɨɬɜɟɧɢ ɩɨ ɬɟɯɧɨɥɨɝɢɹ ɦɟɬɚɥ-ɨɤɢɫ (NMOS, SMOS ɢ ɬ.ɧ.). Ɉɩɢɬɴɬ ɞɨɤɚɡɜɚ, ɱɟ
ɞɚɠɟ ɢ ɦɚɥɤɨ ɤɨɥɢɱɟɫɬɜɨ ɫɬɚɬɢɱɟɫɤɨ ɟɥɟɤɬɪɢɱɟɫɬɜɨ
ɦɨɠɟ ɞɚ ɩɨɜɪɟɞɢ ɢɥɢ ɫɴɫɢɩɟ ɬɟɡɢ ɩɪɢɛɨɪɢ. ɉɨɜɪɟɞɟɧɢɬɟ ɤɨɦɩɨɧɟɧɬɢ ɞɚɠɟ ɚɤɨ ɩɪɢɜɢɞɧɨ
ɪɚɛɨɬɹɬ ɩɪɚɜɢɥɧɨ, ɩɪɨɹɜɹɜɚɬ ɧɚɱɚɥɧɢ ɧɟɢɡɩɪɚɜɧɨɫɬɢ.
Bulgarian
Installation and Operation Manual
X-VA-FC-eng
Part Number: 541B045AAG
December, 2015
A-2
Section A - Essential Instructions
Flow Controllers for Gas and Liquid Service
Základní instrukce
PĜed instalací si pĜeþtČte následující instrukce!
Spoleþnost Brooks Instrument konstruuje, vyrábí a testuje tento produkt tak, aby splnil mnoho národních a mezinárodních standardĤ. PĜístroje musí být
ĜádnČ nainstalovány, používány a udržovány tak, aby byl zajištČn jejich nepĜetržitý provoz v rámci normálních technických specifikací. Musíte dodržovat
následující pokyny a integrovat jejich obsah do svého bezpeþnostního programu pĜi instalování, používání a udržování produktĤ spoleþnosti Brooks.
x Pro zajištČní správné funkce zaĜízení mohou jeho instalaci, obsluhu, programování, údržbu a aktualizace firmwaru provádČt výhradnČ
kvalifikované osoby.
x PĜed instalací, provozem a údržbou produktu si prostudujte všechny pokyny. Pokud tato pĜíruþka není tou správnou pĜíruþkou pro dané
zaĜízení, informujte se na zadní stranČ obálky o kontaktu na místní prodejní kanceláĜ. Uchovejte si tuto pĜíruþku pro pozdČjší potĜebu.
UPOZORNċNÍ: Neprovozujte zaĜízení v rozsahu mimo daný rozsah v provozní pĜíruþce. Porušení tohoto upozornČní mĤže mít za následek
vážné újmy na zdraví a vést k poškození zaĜízení.
x Pokud nČkterým pokynĤm nerozumíte, kontaktujte svého prodejního zástupce spoleþnosti Brooks a vyžádejte si objasnČní.
x Dodržujte všechny výstrahy, upozornČní a pokyny, uvedené a vyznaþené na produktu, nebo s ním dodané.
x Namontujte zaĜízení specifikovaným zpĤsobem podle správné montážní pĜíruþky a podle platných místních a národních pĜedpisĤ. PĜipojte
všechny produkty ke správným zdrojĤm elektrické energie a stlaþených médií.
x Postup: (1) Pomalu do systému pĜivádČjte médium. Pro zabránČní vzniku rázĤ v systému otvírejte procesní ventily postupnČ. (2) PĜekontrolujte
tČsnost vstupního a výstupního pĜipojení prĤtokomČru. Pokud nezjistíte žádné netČsnosti, postupnČ zvedejte tlak na provozní hodnotu.
x PĜed provádČním servisních prací zkontrolujte, zda systém není pod tlakem. V pĜípadČ potĜeby výmČny dílĤ zajistČte, aby byly použity náhradní
souþásti specifikované spoleþností Brooks Instrument a výmČnu provádČla kvalifikovaná osoba. Použití neschválených dílĤ a postupĤ mĤže negativnČ
ovlivnit efektivitu a bezpeþnost procesu. Použití náhrad za originální díly mĤže zpĤsobit požár, úraz elektrickým proudem nebo nesprávnou funkci.
x Pokud není zrovna provádČna údržba kvalifikovanou osobou, ujistČte se, že zaĜízení je opatĜeno všemi pĜedepsanými kryty.
UPOZORNċNÍ: Pokud je u zaĜízení s prĤtokem kapalin nutno z jakéhokoli dĤvodu uzavĜít vstupní a výstupní ventily, je nutné zaĜízení
kompletnČ vyprázdnit. Pokud tak neuþiníte, mĤže z dĤvodu teplotní roztažnosti zbytkĤ média v zaĜízení dojít k jeho poškození nebo k ohrožení
zdraví osob.
Evropská smČrnice pro tlakové zaĜízení (PED)
Na veškerá tlaková zaĜízení s vnitĜním tlakem vyšším než 0,5 baru (g) a velikosti vČtší než 25 mm nebo 1" (palec) se vztahuje platnost smČrnice o
tlakovém zaĜízení (PED).
Kapitola „Technické údaje“ v této pĜíruþce obsahuje dĤležité bezpeþnostní a provozní pokyny související se smČrnicí PED.
x MČĜicí pĜístroje popsané v této pĜíruþce jsou v souladu se smČrnicí EN 97/23/ES.
x Všechny prĤtokomČry spoleþnosti Brooks Instrument spadají do rámce Kapaliny, skupina I.
x MČĜicí pĜístroje vČtší než 25 mm nebo 1" (palec) jsou v souladu se smČrnicí PED, kategorii I, II nebo III
x MČĜicí pĜístroje s velikostí 25 mm nebo 1" (palec) a menší spadají do rámce Správných technických postupĤ (SEP).
Evropská smČrnice pro elektromagnetickou kompatibilitu (EMC)
Elektrické/elektronické zaĜízení Brooks Instrument nesoucí znaþku CE bylo úspČšnČ testováno dle pĜedpisĤ pro elektromagnetickou kompatibilitu
(smČrnice EMC þ. 2004/108/EC).
VýbČru signálních kabelĤ pro použití se zaĜízením oznaþeném CE je nutné vČnovat zvláštní pozornost.
Kvalita signálních kabelĤ, kabelových prĤchodek a konektorĤ:
Brooks Instrument dodává vysoce jakostní kabely splĖující požadavky kvalitativního zaĜazení CE. Pokud chcete použít vlastní signální kabely, zvolte
typy s kvalitním stínČním všech žil a v celé délce trasy.
V pĜípadČ použití konektorĤ kruhových nebo tvaru „D“, musí mít tyto kovové stínČní. V pĜípadČ jejich použití, musí kovové kabelové prĤchodky být
propojeny se stínČním kabelu.
StínČní by mČlo být pĜipojené ke kovovému tČlesu pĜístroje nebo krytu, na obou koncích kabelu a po celém jeho obvodu.
StínČní by mČlo být uzemnČno.
PĜípojky vedoucí ke kartám podle norem jsou nekovová. Pro splnČní požadavkĤ pĜedpisĤ CE musí být použité kabely kompletnČ stínČny.
StínČní by mČlo být uzemnČno.
Konfigurace kontaktĤ je uvedena v pĜiloženém návodu k obsluze.
Elektrostatický výboj (ESD)
UPOZORNċNÍ: Tento pĜístroj obsahuje komponenty citlivé na poškození statickou elektĜinou. PĜi montáži, demontáži þi jiné manipulaci
s vnitĜními elektronickými obvody je potĜeba dodržovat pĜíslušné postupy.
Postup ošetĜování:
1.
Odpojte pĜístroj od napájení.
2.
Osoba provádČjící údržbu má být pĜi instalaci, vyjímání þi práci na desce plošných spojĤ nebo jiné vnitĜní elektronice uzemnČna zemnícím náramkem,
nebo jiným vyhovujícím zpĤsobem.
3.
Desky plošných spojĤ je nutné pĜepravovat v elektricky vodivém obalu. Plošné spoje vyjímejte z vodivého obalu až bezprostĜednČ pĜed instalací do
pĜístroje! Plošné spoje vyjmuté z pĜístroje a urþené pro další využití, opČt neprodlenČ umístČte do ochranného obalu.
Poznámky:
Existence prvkĤ, citlivé na elektrostatické výboje (ESD) v pĜístrojích je þastým jevem. Prvky s technologií oxidu kovĤ (NMOS,SMOS) jsou používány u
vČtšiny moderních elektronických zaĜízení. Zkušenosti dokazují, že i jen malé elektrostatické výboje mohou poškodit nebo zniþit tyto zaĜízení. U
poškozených souþástek, jakkoli zdánlivČ pracujících bezchybnČ, dochází brzy k poruše.
Czech
A-3
Section A - Essential Instructions
Installation and Operation Manual
X-VA-FC-eng
Part Number: 541B045AAG
December, 2015
Flow Controllers for Gas and Liquid Service
Grundlæggende vejledninger
Læs disse før anvendelse!
Brooks Instruments designer, fremstiller og afprøver sine produkter således, at de tilpasser sig både de indenrigs og internationale standarder. Disse
udstyr bør installeres, bruges og repareres omhyggeligt, så at de kan virke tilsvarende deres normale anvendelsesperiode. De følgende regler skal
overholdes og implementeres under installeringen samt ved brug og reparation.
x For at garantere den passende kapacitet, er udstyrets installation, anvendelse, opdatering, programmering kun tilladt for kvalificeret personale.
Alle vejledninger skal læses før produktets installation, anvendelse og reparation.
x Hvis denne manual ikke er den passende udgave, kontakt venligst jeres leverandør for yderligere information.
x Det anbefales at gemme denne manual for senere brug.
OBS.: Udstyret må ikke anvendes til andet end det er angivet i brugsanvisningen. Hvis denne regel brydes, kan der forekomme alvorlige
personskader eller brist på udstyret.
Hvis vejledningerne ikke er forståelig, kontakt venligst Deres Brooks repræsentant for at afklare problemet som er opstået.
x Overhold alle regler, som er markeret eller leveret sammen med udstyret.
x Installer udstyret efter den angivne installationsvejledning og gældende lovgivning for anvendelsesområde. Udstyret må kun tilsluttes med kabler
og stik som overholder kravspecifikationerne i vejledningen.
x Ibrugtagning: (1) Åbn langsomt for trykket i systemet.. Åbn langsomt for alle procesventiler for at forhindre ustabil gas flow. (2) Tjek systemet for
lækage ved tilsluttet måleinstrumenter, samlinger og andet tilsluttet udstyr. Derefter øg trykket i systemet indtil arbejdstrykket er opnået.
x Før reparation tjek altid at procesledningen ikke står under tryk. Hvis der er brug for at udskifte defekte dele må kun kvalificeret personale udføre
arbejdet og af sikkerhedsmæssige årsager må der kun anvendes originale Brooks reservedele. Det er ikke tilladt at anvende reservedele eller
udføre arbejde der på nogen måde kan ændre produktet fra dens oprindelige specifikationer. Manglende overholdelse af de foreskrevne
procedurer kan resultere i brænd, og fare for elektrisk stød eller kortslutning.
x Af sikkerhedsmæssige årsager sørg for at alle sikkerhedsforanstaltninger er overholdt. Eksempelvis at alle afskærmninger eller anden form for
installationsbeskyttelse er lukket eller installeret ved normal drift.
Advarsel.: Ved brug af udstyr som anvendes til væske skal det sikres at indgangsventilen og udgangsventilen ikke bliver lukket
samme tid i forbindelse med aftapning. Såfremt dette ikke overholdes, er der risiko for at væsken på grund af varmeudvikling ekspanderer
og dette kan forårsage skade på udstyr og personer.
Det Europæiske direktiv for trykudstyr (PED)
På alt udstyr hvis indgangstryk er større end 0,5bar (g) og større end 25 mm eller en tomme, gælder det europæiske direktiv for trykapparater.
Manualens afsnit ”tekniske data” indeholder anvisninger om PED direktivet.
x I manualen angives måleinstrumenter der er tilpasset direktivet 97/23/EK EU.
x Alle Brooks gennemstrømningsmålere tilhører væskegruppen nr. 1.
x Alle målinstrumenter som er større end 25 mm eller en tomme beskrives i direktivet PED´s kategorier I, II eller III.
x Alle målinstrumenter som er på 25 mm eller en tomme, eller mindre, beskrives i Sound Engineering Practice (SEP).
Det europæiske direktiv for elektromagnetisk kompatibilitet (EMC)
Alle Brooks instrumenter (elektrisk/elektronisk) som har CE markering er godkendt og testet ifølge om elektromagnetiske kompatibilitets forskrifter
(EMC direktiv 2004/108/EC).
OBS: Man skal være opmærksom på hvilken type kabler der bruges til CE mærket udstyr..
Om kvalitet af signalkabler, kabeltilslutninger og koblinger:
Brooks tilbyder kabler af højest kvalitet, som er tilpasset CEE kvalificeringens forskrifter. Hvis man vælger at bruge egne kabler, skal man vælge et
kabel som har den nødvendige afskærmning for at sikre 100 % mod udefra kommende støj.
Tilslutningerne ”D” eller rundformede tilslutninger skal være afskærmet med skal af metal.
Stikket skal være afskærmet på alle sider. Al afskærmning skal jordes..
Card Edge tilslutninger er ifølge standarden ikke metalliske.. De anvendte kabler og stik skal være 100 % afskærmet for at opfylde CE kravene.. De
skal ligeledes jordes.
For stik konfigurationen se vedlagte brugsvejledning.
Elektrostatisk afladning (ESD)
OBS.: Udstyret indeholder tilbehør som kan skades ved elektrostatisk elektricitet. Alle forskrifter skal overholdes ved kontakt med alle
elektriske komponenter både under drift og vedligeholdelse..
Behandlingsproceduren:
1. Sluk for al strømtilførsel til udstyret.
2. Personer som skal i kontakt med udstyret skal være jordet eller bære anden form for elektrisk beskyttende udstyr. Manglende overholdelse af
dette kan medføre skader på alle elektriske komponenter.
3. Alle elektriske komponenter skal opbevares eller transporteres i deres originale indpakning for at sikre komponenter mod statiske elektriske
skader. Emballagen må ikke åbnes før komponenten skal installeres i udstyret. Ved afslutning af vedligeholdelse/reparation af udstyret, skal
udstyret installeres med det samme eller pakkes forsvarligt hvis det skal på lager eller transporteres.
Bemærkninger:
Dette udstyr er ikke unik i den hensigt, at det indeholder for elektrostatisk afladning (ESD) sensitive reservedel. I de fleste elektronisk udstyr findes
der metaloxyd teknologiske reservedel (NMOS, SMOS m.m.). Erfaringerne viser at selv den mindste statiske elektricitet kan skade, eller ødelægge
disse instrumenter. Selv en fungerende elektrisk del kan have levetiden markant reduceret på grund af statisk elektricitet..
Dansk
Installation and Operation Manual
X-VA-FC-eng
Part Number: 541B045AAG
December, 2015
A-4
Section A - Essential Instructions
Flow Controllers for Gas and Liquid Service
Essentiële instructies
Leeszevoordatuverdergaat!
Brooks Instrument ontwerpt, produceert en test haar producten zodanig dat ze voldoen aan vele nationale en internationale normen. Deze producten moeten
correct worden geïnstalleerd, bediend en onderhouden zodat ze binnen hun normale specificaties blijven werken. De volgende instructies moeten worden
toegevoegd aan en geïntegreerd in uw veiligheidsprogramma als u producten van Brooks Instrument installeert, bedient en onderhoudt.
Om de juiste prestaties te kunnen garanderen mag alleen gekwalificeerd personeel het product installeren, bedienen, updaten, programmeren en
onderhouden.
Lees alle instructies voordat u het product gaat installeren, bedienen en onderhouden. Als dit niet de juiste handleiding is, kijk dan op de achterzijde voor
contactinformatie van uw vertegenwoordiger. Bewaar deze handleiding voor later.
WAARSCHUWING: gebruik dit instrument niet als niet is voldaan aan de specificaties in de handleiding. Het niet naleven van deze waarschuwing kan
ernstig letsel en/of schade aan de apparatuur tot gevolg hebben.
Als u één of meer instructies niet begrijpt, vraag dan om uitleg aan uw vertegenwoordiger van Brooks Instrument.
Neem alle waarschuwingen, voorschriften en instructies in acht die op het product zijn aangebracht of bij het product zijn geleverd.
Installeer uw apparatuur volgens de instructies in de bijgeleverde handleiding en in overeenstemming met de geldende lokale en nationale voorschriften.
Sluit alle producten aan op de juiste elektrische voedings- en drukbronnen.
Bediening: (1) Laat het systeem langzaam volstromen. Open de procesafsluiters langzaam om drukstoten te voorkomen. (2) Controleer op lekkages rondom
de inlaat- en uitlaataansluitingen van de stromingsmeter. Als er geen lekkages zijn, kan het systeem op de bedrijfsdruk worden gebracht.
Zorg ervoor dat de procesleiding drukvrij is gemaakt voordat u servicewerkzaamheden gaat uitvoeren. Als vervangingsonderdelen nodig zijn, zorg er dan
voor dat gekwalificeerd personeel de door Brooks Instrument gespecificeerde vervangingsonderdelen gebruikt. Niet goedgekeurde onderdelen en
procedures kunnen de prestaties van het product en de veilige werking van uw proces in gevaar brengen. Niet goedgekeurde vervangingsonderdelen
kunnen brand, elektrische schokken of een onjuiste werking tot gevolg hebben.
Zorg ervoor dat alle deksels van de apparatuur gesloten zijn en de afdekkingen gemonteerd zijn om elektrische schokken en lichamelijk letsel te voorkomen,
behalve als gekwalificeerd personeel de onderhoudswerkzaamheden uitvoert.
WAARSCHUWING: bij vloeistofstroomapparaten waarvan de inlaat- en uitlaatkleppen om welke reden dan ook gesloten zijn, moet de vloeistof
volledig worden afgetapt. Als dat wordt nagelaten, kan dit leiden tot thermische expansie van de vloeistof waardoor het apparaat kan barsten en
lichamelijk letsel kan veroorzaken.
PED-richtlijn (Pressure Equipment Directive)
Alle drukapparatuur met een interne druk van meer dan 0,5 barg en een diameter van meer dan 25 mm valt onder de PED-richtlijn.
x
In het hoofdstuk Specificaties van deze handleiding staan aanwijzingen die verband houden met de PED-richtlijn.
x
De meters die in deze handleiding worden beschreven, voldoen aan de Europese richtlijn 97/23/EG.
x
Alle stromingsmeters van Brooks Instrument vallen in groep 1.
x
Meters met een diameter van meer dan 25 mm voldoen aan de categorieën I, II of III van de PED-richtlijn.
x
Meters met een diameter van 25 mm of kleiner voldoen aan de regels van goed vakmanschap.
Elektromagnetische compatibiliteit (EMC)
De elektronische apparatuur van Brooks Instrument met de CE-markering is succesvol getest in overeenstemming met de EMC-voorschriften (richtlijn EMC
2004/108/EC).
De keuze van de signaalkabel voor gebruik in combinatie met apparatuur met CE-markering verdient speciale aandacht.
Kwaliteit van de signaalkabel, kabelafdichtingen en stekkers:
Brooks Instrument levert hoogwaardige kabels die voldoen aan de specificaties voor de CE-markering.
Als u zelf voor signaalkabel zorgt, moet u altijd een volledig afgeschermde kabel gebruiken.
Stekkers van het type “D” of ronde stekkers moeten zijn voorzien van een metalen afscherming. Indien nodig moeten metalen kabelafdichtingen worden
gebruikt waarvan de afscherming voor het klemmen van de kabel kan worden gebruikt.
Het kabelscherm moet met het metalen omhulsel of de metalen afdichting worden verbonden en aan beide uiteinden rondom volledig worden afgeschermd.
De afscherming moet aan de aardpotentiaal worden aangesloten.
Card Edge Connectors zijn standaard niet van metaal. De gebruikte kabels moeten volledig zijn afgeschermd om te voldoen aan de CE-markering.
De afscherming moet aan de aardpotentiaal worden aangesloten.
Voor de pinconfiguratie: Raadpleeg de bijgevoegde handleiding.
Elektrostatische ontlading
V
OORZICHTIG: Dit instrument bevat elektronische componenten die gevoelig zijn voor statische elektriciteit. Neem de juiste procedures in acht bij
het verwijderen en installeren of bij andere werkzaamheden aan de interne printplaten of apparaten.
Procedure:
1. Schakel de voeding van de eenheid uit.
2. Het personeel moet zich met een polsbandje of ander veilig en geschikt hulpmiddel aarden voordat een printplaat of ander intern apparaat mag worden
geïnstalleerd, verwijderd of aangepast.
3. Printplaten moeten in een geleidende verpakking worden vervoerd. De platen mogen pas vlak voor de eigenlijke installatie uit de beschermende verpakking
worden gehaald. Verwijderde printplaten moeten onmiddellijk in de beschermende verpakking worden geplaatst om te worden getransporteerd, opgeslagen
of teruggestuurd naar de fabriek.
Opmerkingen
Dit instrument is niet uniek als het gaat om componenten die gevoelig zijn voor elektrostatische ontlading. De meeste moderne elektronische apparaten
bevatten componenten die gebruik maken van de metaaloxidetechnologie (NMOS, SMOS, enz.). Uit ervaring blijkt dat zelfs kleine hoeveelheden statische
elektriciteit deze apparaten al dan niet onherstelbaar kunnen beschadigen. Beschadigde componenten, zelfs als ze goed lijken te functioneren, raken eerder
defect.
Dutch
A-5
Section A - Essential Instructions
Installation and Operation Manual
X-VA-FC-eng
Part Number: 541B045AAG
December, 2015
Flow Controllers for Gas and Liquid Service
Olulised juhised
Enne kasutamist lugege hoolikalt läbi!
Brooks Instrument konstrueerib, valmistab ja katsetab oma tooteid selliselt, et need vastaksid paljude erinevate riiklike ja rahvusvaheliste standardite nõuetele.
Ainult nõuetekohane paigaldamine, kasutamine ja hooldamine tagab toodete katkematu talitluse tavaspetsifikatsiooni raames. Brooks Instrument'i toodete
paigaldamisel, kasutamisel ja hooldamisel tuleb täita alljärgnevaid juhiseid ja integreerida need asjakohasesse ohutusprogrammi.
x Nõuetekohase talitluse tagamiseks tohib toodet paigaldada, kasutada, täiustada, programmeerida ja hooldada ainult kvalifitseeritud personal.
x Enne toote paigaldamist, kasutamist ja hooldamist lugege kõik kasutusjuhised hoolikalt läbi. Kui käesolev kasutusjuhend ei vasta teie tootele, pöörduge
kohaliku edasimüüja poole, kelle kontaktandmed leiate kasutusjuhendi tagakaanelt. Hoidke see kasutusjuhend edaspidiseks alles.
HOIATUS: ärge kasutage seda instrumenti väljaspool kasutusjuhendis spetsifitseeritud piirväärtusi. Selle hoiatuse eiramine võib põhjustada
tõsiseid kehavigastusi ja/või kahjustada seadet.
x Kui te saa mõne juhise mõttest aru, pöörduge selgituste saamiseks kohaliku Brooks Instrument’i edasimüüja poole.
x Järgige kõiki hoiatusi, tähelepanule manitsusi ja juhiseid, mis on tootele peale kantud või tootega kaasa antud.
x Seadme paigaldamisel järgige vastavas kasutusjuhendis toodud paigaldusjuhiseid ning asjakohaseid kohalikke ja riiklikke eeskirju. Ühendage tooted
nõuetekohaste toite- ja surveallikatega.
x Talitlus: (1) Avage aeglaselt vool süsteemi. Vooluimpulsside vältimiseks avage tööventiilid aeglaselt. (2) Kontrollige, et voolukulumõõturi sisend- või
väljundühenduste ümber ei ole lekkeid. Kui lekkeid ei ole, laske süsteemil saavutada töösurve.
x Enne seadme hooldamist veenduge, et kogu süsteem on surve alt vabastatud. Varuosasid tohib vahetada ainult kvalifitseeritud personal, kasutades selleks
Brooks Instrument’i poolt heakskiidetud varuosi. Mitteoriginaalvaruosade kasutamine ja ebapädev toimingute tegemine võivad kahjustada toote tööomadusi
ja põhjustada riski tootmistegevuse ohutuse tagamisel. Originaalvaruosadele sarnaste osade kasutamine võib põhjustada tule- või elektrilöögiohtu või
seadme väärtalitlust.
x Elektrilöögi- ja vigastuseohu vältimiseks peavad seadme luugid olema alati suletud ja kaitsekatted oma kohal, va seadme hooldamisel kvalifitseeritud isikute
poolt.
HOIATUS: voolava vedelikuga seadmete kasutamisel – kui seadmega külgnevad sisend- ja väljundklapid on vaja mingil põhjusel sulgeda,
tuleb seadmed vedelikust täiesti tühjaks lasta. Vastasel korral võib vedelik soojuse mõjul paisuda niivõrd, et seade puruneb. See võib põhjustada
tõsiseid kehavigastusi.
Euroopa surveseadmete direktiiv (PED)
Euroopa surveseadmete direktiiv kohaldub kõikidele surveseadmetele, mille sisesurve on üle 0,5 baari (g) ja läbimõõt üle 25 mm või 1 tolli.
x Käesoleva kasutusjuhendi spetsifikatsiooniosa sisaldab surveseadmete direktiiviga seonduvaid juhiseid.
x Käesolevas kasutusjuhendis kirjeldatud mõõturid vastavad EN direktiivi 97/23/EÜ nõuetele.
x Brooks Instrument’i voolukulumõõturid kuuluvad vedelike 1. gruppi.
x Mõõturid läbimõõduga üle 25 mm või 1 tolli vastavad surveseadmete direktiivi kategooriale I, II või III.
x Mõõturitele läbimõõduga alla 25 mm või 1 tolli kohaldatakse häid inseneritavasid.
Euroopa elektromagnetilise ühilduvuse direktiiv (EMÜ)
Brooks Instrument’i (elektrilised/elektroonilised) seadmed, millele on omistatud CE-tähis, on edukalt läbinud asjakohased katsed ja vastavad elektromagnetilise
ühilduvuse nõuetele (EMÜ direktiiv 2004/108/EC).
Kuid signaalkaabli valimisel on vaja pöörata suurt tähelepanu CE-tähisega seadmetele.
Signaalkaabli, läbiviigutihendite ja konnektorite kvaliteet
Brooks Instrument turustab kõrgekvaliteedilisi kaableid, mis vastavad CE-sertifikaadi nõuetele.
Olemasoleva kaabli kasutamisel jälgige, et kaabel oleks täielikult ümbritsetud varjestusega.
„D” või „Ring“-tüüpi konnektorid peavad olema varustatud metallvarjestusega. Kus kohaldatav, tuleb kasutada metallist läbiviike, mis tagavad kaabli varjestuse
ühenduse.
Kaabli varjestus ühendatakse metallkesta või läbiviigutihendiga ja on mõlemast otsast kaitstud 360° ulatuses.
Varjestus peab olema maandatud.
Mikroskeemide servaühendused on üldjuhul mittemetallist. Vastavuse tagamiseks CE-sertifikaadi nõuetele peavad kasutatud kaablid olema 100% varjestatud.
Varjestus peab olema maandatud.
Klemmide konfigureerimine: vt komplekti kuuluvat kasutusjuhendit.
Elektrostaatiline laeng
TÄHELEPANU: seade sisaldab staatilise elektri suhtes tundlikke elektroonikakomponente. Seadmesse paigaldatud trükkplaatide
eemaldamisel ja paigaldamisel, samuti trükkplaadi või seadmega muude toimingute teostamisel järgige nõuetekohase käsitsemise juhiseid.
Käsitsemisjuhised
1. Lahutage seade toiteallikast.
2. Enne trükkplaadi või mõne muu siseelemendi paigaldamist, eemaldamist või konfigureerimist peab personal olema maandatud läbi randmepaela või mõne
muu sobiva vahendi.
3. Trükkplaate transporditakse voolujuhtivas konteineris. Võtke trükkplaat kaitsvast konteinerist välja vahetult enne selle paigaldamist. Seadmest eemaldatud
trükkplaadid tuleb viivitamatult asetada kaitsvasse konteinerisse kas siis edasiseks transportimiseks, hoiustamiseks või tehasesse tagasisaatmiseks.
Kommentaarid
See seade ei ole ainus, mis sisaldab staatilise elektri suhtes tundlikke elemente. Enamik kaasaegsetest elektroonikaseadmetest sisaldavad komponente, mille
valmistamiseks on kasutatud metalloksiidtehnoloogiat (NMOS, SMOS jne). Kogemused näitavad, et isegi väike kogus staatilist elektrit võib neid seadmeid
kahjustada või isegi hävitada. Kuigi võib näida, et kahjustatud komponendid töötavad nõuetekohaselt, hakkavad talitlushäired ilmnema juba varakult.
Estonian
Installation and Operation Manual
X-VA-FC-eng
Part Number: 541B045AAG
December, 2015
A-6
Section A - Essential Instructions
Flow Controllers for Gas and Liquid Service
Perusohjeet
Lue ensin ohjeet huolellisesti!
Brooks Instrument suunnittelee, valmistaa ja testaa laitteensa vastaamaan useimpien kotimaisten ja kansainvälisten standardien
vaatimuksia. Tuotteet tulee asentaa, käyttää ja huoltaa käyttöohjeiden mukaan jotta niiden toimivuus taataan. Brooks Instrumentin
laitteiden asennuksessa, käytössä ja huollossa on noudatettava soveltuvia määräyksiä ja ohjeita, lisäksi mainitut ohjeet on
huomioitava työsuojelun ohjeistuksessa.
Oikean toiminnan varmistamiseksi vain valtuutettu huoltohenkilö saa asentaa, käynnistää, päivittää, ohjelmoida ja huoltaa
laitteita.
Lue kaikki käyttöohjeet koskien tuotteen asennusta, käyttöä ja huoltoa. Jos käyttöohje on puutteellinen, lisätietoja saa paikalliselta
jälleenmyyjältä. Yhteystiedot löytyvät oppaan kansilehdestä. Säilytä ohjeet.
VAROITUS!: Käyttöohjeessa ilmoitettujen standardien mukaisia ohjeita ja raja-arvoja ei saa ylittää. Rajoitusten
laiminlyönti voi aiheuttaa tuotteen rikkoutumisen ja/tai vakavan henkilövahingon vaaran.
x Jos ohjeissa on epäselvyyttä, ota yhteyttä Brooks Instrumentin edustajaan ongelman selvittämiseksi.
x Noudata kaikkia laitteessa olevia tai siihen liittyviä ohjeita, määräyksia ja varoituksia.
x Laittteen asennuksessa on noudatettava erityisiä asennusohjeita sekä voimassa olevia paikallisia ja kansainvälisiä määräyksiä.
Laitteet saa yhdistää vain soveltuvaan sähkö- ja paineverkkoon.
x Asennusohjeita: (1) Päästä virtaus hitaasti järjestelmään. Avaa venttiilit hitaasti, jotta virtaus pysyy tasaisena. (2) Tarkista, ettei
virtausmittarin sisään- ja ulosmenon vieressä ole vuotoa. Jos järjestelmässä ei ole vuotoa, aseta oikea käyttöpaine.
x Tarkista, että laitteeseen menevä paine on katkaistu ennen laitteen korjaamista välttääksesi äkillisen painepäästön aiheuttaman
loukkaantumisriskin. Mahdollisten varaosien tulee olla Brooks Instrumentin hyväksymiä. Vain valtuutettu huoltohenkilö saa
asentaa varaosat. Ei-hyväksyttyjen varaosien käyttö voi vahingoittaa tuotteen toimintaa ja aiheuttaa turvallisuusriskin. Samoin ei-
hyväksyttyjen varaosien käyttö voi aiheuttaa tulipalon, sähköiskun tai virhetoiminnan riskin.
x Varmista että kaikki kaikki laitteen ovet/luukut ovat suljettuina ja tarkista että suojakannet ovat paikoillaan estääksesi mahdollisen
sähköisku- ja loukkaantumisvaaran.
VAROITUS!: Jos järjestelmässä virtaa neste ja laitteen sisään- ja ulosmenoventtiilit pitää sulkea, laite on ensin
tyhjennettävä kokonaan. Tyhjentämisen laiminlyönti aiheuttaa nesteen lämpölaajenemista, joka saattaa johtaa laitteen
rikkoutumiseen ja henkilövahingon vaaraan.
Eurooppalainen painelaitedirektiivi (PED)
Painelaitteet, joidenpaine on suurempi kuin 0,5 bar ja joiden koko on suurempi kuin 25 mm tai 1 tuuma , kuuluvat eurooppalaiseen
painelaitedirektiiviin (PED).
x PED direktiiviä koskevat määräykset löytyvät käyttöoppaan ’’Tekniset tiedot” -luvusta.
x yttöoppaassa kuvatut mittarit ovat 97/23/EC EU-direktiivin mukaisia.
x Kaikki Brooks Instrumentin virtausmittarit kuuluvat virtausryhmään 1. Laitteet jotka ovat suurempia, kuin 25 mm tai 1 tuuma, ovat
PED I, II, III kategorien mukaisia.
x Mittarit joiden koko on alle 25 mm tai 1 tuuma ovat hyvän konepajakäytännön (SEP) mukaisia.
Eurooppalainen direktiivi sähkömagneettisesta yhteensopivuudesta (EMC)
Brooks Instrumentin CE-merkin saaneet (sähkö/sähköiset) laitteet täyttävät EMC direktiivin vaatimukset ja testit sähkömagneettisesta
yhteensopivuudesta (2004/108/EC EMC direktiivi).
Erityistä huomioita on kiinnitettävä CE-merkittyjen laitteiden käytössä olevien kaapelien valintaan.
Kaapelien, kiinnikkeiden ja liittimien laatu:
Brooks Insturmentin kaapelit ovat korkealaatuisia ja täyttävät CE-merkintä direktiivin vaatimukset.
Muun valmistajan kaapelia käytettäessä on käytettävä 100% suojattua kaapelia.
Liittimien tulee olla häiriösuojattua tyyppiä. Tarvittaessa käytetään metallisia kiinnikkeitä kaapelin suojuksen kiinnittämiseen. Kaapelin
suojakuoren pitää olla yhdistettynä metallisuojukseen tai laippaan ja sen pitää olla molemmista päistä suojattuna 360
o
. Suojaus
päättyy maadoitukseen.
Standardin mukaan korttien liittimet eivät ole metallisia. Käytettyjen kaapelien suojaus on oltava 100%, jotta se täyttäisi CE-
merkinnän direktiivin vaatimukset.
Suojaus päättyy maadoitukseen.
Napojen järjestys: Katso liitteenä oleva käyttöopas.
Elektrostaattinen purkaus (ESD)
VAROITUS!: Tuote sisältää elektroniikkakomponentteja jotka voivat vahingoittua staattisesta sähköstä. Sisäisten
piirilevyjen purkamisessa,asennuksessa ja käsittelyssä tulee noudattaa kaikkia määräyksiä ja ohjeita.
Asennusohjeet:
1. Järjestelmän sähköt katkaistaan.
2. Laitteen kanssa työskentelevä henkilö on suojattava sähköiskuilta rannehihnalla tai muulla suojavarustuksella ennen piirilevyn tai
muun sisäosan asennusta, poistamista tai korjaamista.
3. Piirilevyt kuljetetaan konduktiivisessa pakkauksessa. Piirilevyt puretaan paketista juuri ennen asennusta. Poistettu piirilevy on heti
pakattava soveltuvaan suojapakkaukseen kuljettamista, varastoimista tai palautusta varten.
Huomautukset:
Tuotteen herkkyys elektrostaattiselle purkaukselle (ESD) ei ole epätavallista. Suurin osa elektroniikkatuotteista sisältää
komponentteja jotka hyödyntävät metallioksiditekniikkaa (NMOS, SMOS jne.) Kokemusten mukaan pienikin elektrostaattinen purkaus
voi aiheuttaa laitteiden virhetoiminnan tai vahingoittumisen. Vahingoittuneet komponentit saattavat aiheuttaa laitteen ennenaikaisen
rikkoutumisen vaikka laite näyttäisi toimivan normaalisti.
Finnish
A-7
Section A - Essential Instructions
Installation and Operation Manual
X-VA-FC-eng
Part Number: 541B045AAG
December, 2015
Flow Controllers for Gas and Liquid Service
Instructions essentielles
A lire avant de commencer !
Brooks Instrument conçoit, fabrique et teste ses produits pour répondre à de nombreuses normes nationales et internationales. Ces produits doivent être
correctement installés, utilisés et entretenus pour pouvoir fonctionner dans le cadre de leurs spécifications normales. Les instructions qui suivent doivent être
respectées et intégrées à votre programme de sécurité lors de l’installation, l’utilisation et l’entretien des produits Brooks Instrument.
• Afin d’assurer un fonctionnement correct, faites appel à du personnel qualifié pour l’installation, l’utilisation, la mise à jour, la programmation et l’entretien du
produit.
• Lisez toutes les instructions avant l’installation, l’utilisation et l’entretien du produit. Si le présent manuel d’utilisation n’est pas le bon, consultez la dernière
page de la couverture pour connaître le point de vente le plus proche. Conservez ce manuel d’utilisation pour pouvoir vous y reporter par la suite.
AVERTISSEMENT : n’utilisez pas cet instrument au-delà des spécifications énumérées dans le manuel d’utilisation.
Le non-respect de cet avertissement peut entraîner de graves blessures et / ou endommager l’équipement.
• Si vous ne comprenez pas l’une des instructions, prenez contact avec un représentant de Brooks Instrument pour obtenir des explications.
• Tenez compte de tous les avertissements, précautions et instructions marquées sur le produit et fournies avec celui-ci.
• Installez votre équipement de la façon indiquée dans les instructions d’installation du manuel d’utilisation et conformément à la législation en vigueur au niveau
local et national. Branchez tous les produits aux sources d’électricité et de pression agréées.
• Utilisation : (1) Faites lentement entrer le débit dans le système. Ouvrez progressivement les vannes de procédé pour éviter des pics de débits. (2) Vérifiez
qu’il n’y a pas de fuite au niveau des branchements d’entrée et de sortie du débitmètre. S’il n’y a pas de fuite, amenez le système à sa pression d’utilisation.
• Avant de procéder à l’entretien, assurez-vous que la conduite de procédé n’est plus sous pression. Lorsqu’il faut remplacer une pièce, assurez-vous que les
pièces de rechange sont celles indiquées par Brooks Instrument et que des personnes qualifiées effectuent le remplacement. Les pièces et procédures non
autorisées peuvent porter atteinte au fonctionnement du produit et mettre en péril la sécurité de votre procédé. Les remplacements par des pièces d’apparence
similaire peuvent entraîner des incendies, des risques électriques ou un mauvais fonctionnement.
• Vérifiez que toutes les trappes de l’équipement sont fermées et que les couvercles de protection sont en place pour éviter les chocs électriques et les
blessures, sauf lorsque l’entretien est réalisé par des personnes qualifiées.
AVERTISSEMENT : dans le cas d’appareils à écoulement liquide, si les vannes d’entrée et de sortie adjacentes aux appareils doivent être fermées pour une
raison quelconque, les appareils doivent être complètement vidangés. Si cela n’est pas fait, une éventuelle dilatation thermique du fluide peut casser l’appareil
et provoquer des blessures.
Directive européenne « équipements sous pression » (PED)
Tous les équipements sous pression dont la pression interne est supérieure à 0,5 bar (pression relative) et dont la taille dépasse 25 mm ou un pouce entrent
dans le cadre de la directive PED.
• La section « Spécifications » de ce manuel contient les instructions relatives à la directive PED.
• Les appareils de mesure de ce manuel sont conformes à la directive EN 97/23/EC.
• Tous les débitmètres Brooks Instrument fonctionnent avec des fluides de groupe 1.
• Les appareils de mesure d’une taille supérieure à 25 mm ou un pouce entrent dans la catégorie PED I, II ou III.
• Les appareils de mesure d’une taille inférieure ou égale à 25 mm ou un pouce relèvent des « bonnes pratiques d’ingénierie » (SEP).
Compatibilité électromagnétique européenne (CEM)
L’équipement Brooks Instrument (électrique / électronique) portant le marquage CE répond à la réglementation en matière de compatibilité électromagnétique
(directive CEM 2004/108/EC).
Il faut cependant prêter une grande attention au choix du câble d’interconnexion à utiliser avec l’équipement marqué CE.
Qualité du câble d’interconnexion, des presse-étoupes et connecteurs :
Brooks Instrument fournit un ou des câbles de qualité supérieure qui répondent aux spécifications exigées pour la certification CE.
Si vous utilisez votre propre câble d’interconnexion, ce câble doit être protégé par un blindage intégral.
Les connecteurs rectangulaires ou circulaires utilisés doivent avoir un blindage métallique. S’il y a lieu, des presse-étoupes métalliques doivent faire office de
serre-écran de câble.
L’écran du câble doit être raccordé à l’enveloppe métallique ou au presse-étoupe et blindé aux deux extrémités sur 360 degrés.
Le blindage doit s’achever sur une prise de terre.
Les connecteurs de carte standards sont non métalliques. Les câbles utilisés doivent être protégés par un blindage intégral pour se conformer à la certification
CE.
Le blindage doit s’achever sur une prise de terre.
En ce qui concerne la configuration des broches, veuillez vous reporter au manuel d’utilisation joint.
ESD (décharge électrostatique)
ATTENTION : cet instrument contient des composants électroniques sensibles à l’électricité statique. Des procédures de manipulation adéquates
doivent être respectées pendant le retrait, l’installation ou la manipulation des cartes de circuits imprimés ou des dispositifs internes.
Procédure de manipulation :
1. L’alimentation électrique de l’appareil doit être coupée.
2. Le personnel doit être mis à la terre, au moyen d’une bande de poignet ou d’un autre moyen sûr et adéquat, avant l’installation, le retrait ou le réglage de
toutes les cartes de circuits imprimés ou autres dispositifs internes.
3. Les cartes de circuits imprimés doivent être transportées dans un récipient conducteur. Les cartes ne doivent enlevées de cette enveloppe protectrice qu’au
dernier moment, juste avant l’installation. Les cartes retirées doivent être immédiatement placées dans un récipient de protection pour le transport, le stockage
ou le retour à l’usine.
Observations
Brooks Instrument n’est pas le seul à proposer des produits comportant des composants sensibles aux décharges électrostatiques. La plupart des produits
électroniques modernes contiennent des composants qui utilisent des technologies à oxydes métalliques (NMOS, SMOS, etc.). L’expérience démontre que
d’infimes quantités d’électricité statique suffisent à endommager ou détruire ces appareils. Les composants endommagés, même s’ils semblent fonctionner
correctement, tombent rapidement en panne.
French
Installation and Operation Manual
X-VA-FC-eng
Part Number: 541B045AAG
December, 2015
A-8
Section A - Essential Instructions
Flow Controllers for Gas and Liquid Service
Wichtige Anweisungen
Bitte zuerst lesen!
Brooks Instrument entwickelt, produziert und testet seine Produkte derart, dass sie viele nationale und internationale Standards erfüllen. Nur bei korrektem Einbau
sowie richtiger Bedienung und Wartung dieser Produkte ist ein Betrieb unter Einhaltung der Standardvorgaben sichergestellt. Die folgenden Anweisungen müssen
eingehalten werden und in Ihr Sicherheitsprogramm integriert werden, wenn Sie Brooks Produkte installieren, bedienen und warten.
Um die entsprechende Leistung zu gewährleisten, setzen Sie qualifiziertes Personal für die Installation, den Betrieb, die Aktualisierung, Programmierung und
Wartung des Produkts ein.
Lesen Sie alle Anweisungen, bevor Sie das Produkt installieren, in Betrieb nehmen und warten. Falls es sich bei diesem Handbuch nicht um das richtige
Handbuch handelt, schauen Sie bitte auf der Rückseite nach den Kontaktdaten Ihres Vertriebsbüros vor Ort. Bewahren Sie dieses Handbuch auf, falls Sie
später etwas nachschauen möchten.
WARNUNG: Dieses Gerät nicht außerhalb der in Bedienungsanleitung und Handbuch angegebenen Grenzen betreiben. Wird diese Warnung nicht
beachtet, kann dies zu schweren Personenschäden bzw. Schäden des Gerätes führen.
Falls Sie Anweisungen nicht verstehen, wenden Sie sich zur Klärung an Ihren Brooks Instrument Vertreter.
Befolgen Sie alle Warnhinweise und Anweisungen, die auf dem Produkt markiert sind oder zusammen mit diesem geliefert werden.
Installieren Sie Ihr Gerät, wie in den Installationsanweisungen des entsprechenden Handbuchs angegeben und gemäß der gültigen regionalen und nationalen
Gesetze. Schließen Sie alle Produkte an eine geeignete Strom- und Druckluftversorgung an.
Bedienung: (1) Langsam den Zufluss zum System starten. Die Ventile langsam öffnen, um einen sprunghaften Anstieg der Durchflussmenge zu verhindern. (2)
Bereich der Anschlüsse (Zufluss und Ausfluss) des Durchflussmessers auf Undichtigkeiten überprüfen. Wenn das System dicht ist, auf Betriebsdruck
hochfahren.
Sicherstellen, dass der Leitungsdruck vor Wartungsarbeiten heruntergefahren wird. Wenn Ersatzteile benötigt werden, stellen Sie sicher, dass qualifizierte
Personen Ersatzteile verwenden, die von Brooks Instrument vorgegeben sind. Nicht genehmigte Teile und Verfahren können die Leistungsfähigkeit des
Produkts beeinträchtigen und den sicheren Betrieb Ihres Prozesses gefährden. Ähnlich aussehende Austauschteile können zu Bränden, elektrischen Gefahren
oder nicht sachgerechtem Betrieb führen.
Stellen Sie sicher, dass alle Türen der Anlage geschlossen sind und dass alle Schutzabdeckungen angebracht sind, um Stromschläge und Personenschäden
zu vermeiden, es sei denn die Wartungsaufgaben werden von qualifizierten Personen durchgeführt.
WARNUNG: Werden die Ein- und Auslassventile neben Durchflussmessgeräten aus irgendwelchen Gründen geschlossen, so müssen die Geräte
komplett entleert werden.
Durchflussmessgeraete muessen vor dem Schliessen von Ein- und Auslassventilen komplett entleert werden,
anderenfalls kann es zu einer thermischen Ausdehnung der Flüssigkeit und damit zum Bruch des Gerätes kommen; Personenschäden können die
Folge sein.
Europäische Druckgeräterichtlinie (PED)
Alle Druckgeräte mit einem internen Druck von mehr als 0,5 bar (g) und einer Größe von mehr als 1in ( 1 in = 25,4 mm) unterliegen der Druckgeräterichtlinie.
x
Das Kapitel zu den technischen Daten in dieser Anleitung enthält wichtige Sicherheits- und Betriebsanweisungen in Bezug auf die Druckgeräterichtlinie.
x
Messgeräte, die in diesem Handbuch beschrieben sind, erfüllen die europäische Richtlinie 97/23/EG.
x
Alle Durchflussmesser von Brooks Instrument fallen unter die Fluidgruppe 1.
x
Messgeräte, die größer als 25 mm oder 1“ (inch) sind, erfüllen die Kategorien I, II oder III der Druckgeräterichtlinie (PED).
x
Messgeräte mit einer Größe von 25 mm oder 1“ (inch) oder kleiner sind Sound Engineering Practice (SEP).
Europäische Verordnung zur elektromagnetischen Verträglichkeit (EMV)
Geräte von Brooks Instrument (elektrischer und elektronischer Art) mit CE-Zeichen haben den Test auf Einhaltung der Verordnung zur elektromagnetischen
Verträglichkeit (EMV Richtlinie 2004/108/EC) erfolgreich bestanden.
Dennoch muss bei der Wahl des Signalkabels für das Gerät mit CE-Zeichen auf folgende Dinge geachtet werden.
Qualität von Signalkabel, Kabeldurchführung und Anschlüsse:
Brooks Instrument liefert qualitativ hochwertige Kabel, die den Anforderungen für eine CE-Zertifizierung entsprechen.
Sollten Sie eigene Kabel einsetzen, so sollte das Kabel überall mit einer 100%-Abschirmung versehen sein.
D- oder Rundstecker sollten eine Metallabschirmung aufweisen. Wenn möglich, müssen Kabeldurchführungen aus Metall mit Kabelschirmgeflechts-Klemmen
verwendet werden.
Der Kabelschirm sollte an die Metallhülle oder -durchführung angeschlossen werden und an beiden Enden rundherum (360 °) abgeschirmt werden.
Die Abschirmung sollte geerdet werden.
Randstecker auf Platinen sind standardmäßig nicht aus Metall. Die verwendeten Kabel müssen mit einer 100 % Abschirmung versehen werden, um die CE-
Vorgaben zu erfüllen.
Die Abschirmung sollte geerdet werden.
Klemmenbelegung: Siehe beigefügtes Handbuch.
ESD (Elektrostatische Entladung)
ACHTUNG: Dieses Gerät enthält elektronische Komponenten, die durch elektrostatische Entladungen beschädigt werden können. Ordnungsgemäße
Verfahrensanweisungen müssen während des Ausbaus, der Installation oder anderer Handhabung der eingebauten Platinen oder Geräte eingehalten
werden.
Verfahrensanweisung:
1. Trennen Sie das Gerät von der Stromversorgung.
2. Das Personal ist vor dem Einbau, Ausbau oder der Einstellung von Platinen oder anderen internen Komponenten durch ein entsprechendes Armband mit dem
Erdpotential zu verbinden.
3. Platinen sind in speziellen Behältern mit Schutz gegen elektrostatische Spannungen zu transportieren oder zu lagern. Platinen dürfen erst kurz vor dem Einbau
aus der Schutzhülle entfernt werden. Ausgebaute Platinen müssen umgehend in Schutzbehälter zum Transport, zur Lagerung oder Rücksendung an das Werk
gelegt werden.
Anmerkung
Dieses Gerät ist wie viele andere elektronische Geräte auch mit Komponenten bestückt, die anfällig für elektrostatische Entladung sind. Die meisten modernen,
elektronischen Geräte enthalten Komponenten, die die Metalloxidtechnologie (NMOS, SMOS etc.) verwenden. Die Erfahrung hat gezeigt, dass schon geringe
Mengen elektrostatischer Energie ausreichen, um diese Geräte zu beschädigen oder zu zerstören. Beschädigte Teile fallen früh aus, obwohl sie funktionsfähig zu
sein scheinen.
German
A-9
Section A - Essential Instructions
Installation and Operation Manual
X-VA-FC-eng
Part Number: 541B045AAG
December, 2015
Flow Controllers for Gas and Liquid Service
ǺĮıȚțȑȢ ȠįȘȖȓİȢ
ǻȚĮȕȐıIJİ ʌȡȚȞ ıȣȞİȤȓıİIJİ!
Ǿ Brooks Instrument ıȤİįȚȐȗİȚ, ʌĮȡȐȖİȚ țĮȚ įȠțȚȝȐȗİȚ IJĮ ʌȡȠȧȩȞIJĮ IJȘȢ ıİ ıȣȝȝȩȡijȦıȘ ȝİ ʌȜȒșȠȢ İșȞȚțȫȞ țĮȚ įȚİșȞȫȞ ʌȡȠIJȪʌȦȞ. Ǿ ıȦıIJȒ
İȖțĮIJȐıIJĮıȘ, ȤȡȒıȘ țĮȚ ıȣȞIJȒȡȘıȒ IJȠȣȢ ĮʌȠIJİȜİȓ ĮʌĮȡĮȓIJȘIJȘ ʌȡȠȨʌȩșİıȘ IJȘȢ ȜİȚIJȠȣȡȖȓĮȢ İȞIJȩȢ IJȦȞ țĮȞȠȞȚțȫȞ ȠȡȓȦȞ. ȅȚ ʌĮȡĮțȐIJȦ ȠįȘȖȓİȢ
ʌȡȑʌİȚ ȞĮ IJȘȡȠȪȞIJĮȚ țĮȚ ʌȡȑʌİȚ ȞĮ İȞıȦȝĮIJȦșȠȪȞ ıIJȠ ʌȡȩȖȡĮȝȝĮ ĮıijȐȜİȚĮȢ IJȘȢ İȡȖĮıȓĮȢ ıĮȢ țĮIJȐ IJȘȞ İȖțĮIJȐıIJĮıȘ
, ȤȡȒıȘ țĮȚ ıȣȞIJȒȡȘıȘ
ʌȡȠȧȩȞIJȦȞ IJȘȢ Brooks Instrument.
x īȚĮ ıȦıIJȩ ĮʌȠIJȑȜİıȝĮ Ș İȖțĮIJȐıIJĮıȘ, ȜİȚIJȠȣȡȖȓĮ, İȞȘȝȑȡȦıȘ, ʌȡȠȖȡĮȝȝĮIJȚıȝȩȢ țĮȚ ıȣȞIJȒȡȘıȘ ʌȡȑʌİȚ ȞĮ ȖȓȞİIJĮȚ Įʌȩ İȚįȚțİȣȝȑȞȠ ʌȡȠıȦʌȚțȩ.
x ǻȚĮȕȐıIJİ ȩȜİȢ IJȚȢ ȠįȘȖȓİȢ ʌȡȚȞ İȖțĮIJĮıIJȒıİIJİ, ȜİȚIJȠȣȡȖȒıİIJİ țĮȚ ıȣȞIJȘȡȒıİIJİ IJȠ ʌȡȠȧȩȞ. ǼȐȞ IJȠ ʌĮȡȩȞ İȖȤİȚȡȓįȚȠ įİȞ İȓȞĮȚ IJȠ ıȦıIJȩ İȖȤİȚȡȓįȚȠ,
ıȣȝȕȠȣȜİȣșİȓIJİ IJȠ ʌȓıȦ İȟȫijȣȜȜȠ ȖȚĮ IJĮ ıIJȠȚȤİȓĮ
İʌȚțȠȚȞȦȞȓĮȢ IJȠȣ IJȠʌȚțȠȪ ĮȞIJȚʌȡȠıȫʌȠȣ. ĭȣȜȐȟIJİ IJȠ İȖȤİȚȡȓįȚȠ ĮȣIJȩ ȖȚĮ ȝİȜȜȠȞIJȚțȒ ĮȞĮijȠȡȐ.
ȆȇȅǼǿǻȅȆȅǿǾȈǾ: ȂȘ ȜİȚIJȠȣȡȖİȓIJİ IJȘ ıȣıțİȣȒ ĮȣIJȒ țĮșȣʌȑȡȕĮıȘ IJȦȞ ȠȡȓȦȞ ʌȠȣ ĮȞĮȖȡȐijȠȞIJĮȚ ıIJȠ ǼȖȤİȚȡȓįȚȠ ȅįȘȖȚȫȞ țĮȚ
ȁİȚIJȠȣȡȖȓĮȢ. Ǿ ȝȘ ıȣȝȝȩȡijȦıȘ ȝİ IJȘȞ ʌȡȠİȚįȠʌȠȓȘıȘ ĮȣIJȒ ȝʌȠȡİȓ ȞĮ ȠįȘȖȒıİȚ ıİ ıȠȕĮȡȩ ʌȡȠıȦʌȚțȩ IJȡĮȣȝĮIJȚıȝȩ Ȓ/țĮȚ ȗȘȝȚȐ ıIJȠȞ
İȟȠʌȜȚıȝȩ.
x Ȉİ ʌİȡȓʌIJȦıȘ ȝȘ țĮIJĮȞȩȘıȘȢ țȐʌȠȚĮȢ Įʌȩ IJȚȢ ȠįȘȖȓİȢ ȗȘIJȒıIJİ įȚİȣțȡȚȞȓıİȚȢ Įʌȩ IJȠȞ IJȠʌȚțȩ ĮȞIJȚʌȡȩıȦʌȠ
IJȘȢ Brooks Instrument.
x ȉȘȡİȓIJİ ȩȜİȢ IJȚȢ ʌȡȠİȚįȠʌȠȚȒıİȚȢ, ʌȡȠijȣȜȐȟİȚȢ țĮȚ ȠįȘȖȓİȢ ʌȠȣ ĮȞĮȖȡȐijȠȞIJĮȚ Ȓ ıȣȞȠįİȪȠȣȞ IJȠ ʌȡȠȧȩȞ.
x ǼȖțĮIJĮıIJȒıIJİ IJȘ ıȣıțİȣȒ ȩʌȦȢ ʌȡȠȕȜȑʌİIJĮȚ ıIJȚȢ ȠįȘȖȓİȢ İȖțĮIJȐıIJĮıȘȢ IJȠȣ ıȦıIJȠȪ İȖȤİȚȡȚįȓȠȣ ȠįȘȖȚȫȞ țĮȚ ıIJȚȢ țİȓȝİȞİȢ IJȠʌȚțȑȢ țĮȚ İșȞȚțȑȢ
įȚĮIJȐȟİȚȢ. ȈȣȞįȑıIJİ IJĮ ʌȡȠȧȩȞIJĮ ıIJȚȢ İțȐıIJȠIJİ ıȦıIJȑȢ ʌĮȡȠȤȑȢ ȡİȪȝĮIJȠȢ țĮȚ ʌȓİıȘȢ.
x ǻȚĮįȚțĮıȓĮ: (1) ǹijȒıIJİ ȞĮ ȟİțȚȞȒıİȚ
ĮȡȖȐ Ș ȡȠȒ ıIJȠ ıȪıIJȘȝĮ. ǹȞȠȓȟIJİ ĮȡȖȐ IJȚȢ ȕĮȜȕȓįİȢ ȜİȚIJȠȣȡȖȓĮȢ ȖȚĮ ȞĮ ĮʌȠijȪȖİIJİ IJȚȢ ĮʌȩIJȠȝİȢ ĮȣȟȠȝİȚȫıİȚȢ
ȡȠȒȢ. (2) ǼȜȑȖȟIJİ ȖȚĮ įȚĮȡȡȠȑȢ IJȚȢ ıȣȞįȑıİȚȢ İȚıȩįȠȣ țĮȚ İȟȩįȠȣ IJȠȣ ȡȠȩȝİIJȡȠȣ. ǹȞ įİȞ ȣʌȐȡȤȠȣȞ įȚĮȡȡȠȑȢ, ȖİȝȓıIJİ IJȠ ıȪıIJȘȝĮ ȝȑȤȡȚ Ș ʌȓİıȘ ȞĮ
ijIJȐıİȚ IJȘȞ țĮȞȠȞȚțȒ ʌȓİıȘ İȡȖĮıȓĮȢ.
x ȆȡȚȞ Įʌȩ IJȘ ıȣȞIJȒȡȘıȘ ȕİȕĮȚȦșİȓIJİ ȩIJȚ ȖȡĮȝȝȒ
İȡȖĮıȓĮȢ ȑȤİȚ IJİșİȓ İțIJȩȢ ʌȚȑıİȦȢ. Ȉİ ʌİȡȓʌIJȦıȘ ĮȞIJȚțĮIJȐıIJĮıȘȢ ĮȞIJĮȜȜĮțIJȚțȫȞ ȕİȕĮȚȦșİȓIJİ ȩIJȚ
IJȠ ʌȡȠıȦʌȚțȩ İȓȞĮȚ İȚįȚțİȣȝȑȞȠ țĮȚ ȤȡȘıȚȝȠʌȠȚİȓ ĮȞIJĮȜȜĮțIJȚțȐ ʌȠȣ ʌȡȠȕȜȑʌİȚ Ș Brooks Instrument. ȂȘ İȖțİțȡȚȝȑȞĮ ĮȞIJĮȜȜĮțIJȚțȐ țĮȚ İʌİȝȕȐıİȚȢ
İȞįȑȤİIJĮȚ ȞĮ İʌȘȡİȐıȠȣȞ IJȚȢ İʌȚįȩıİȚȢ IJȠȣ ʌȡȠȧȩȞIJȠȢ țĮȚ ȞĮ ʌȡȠțĮȜȑıȠȣȞ țȓȞįȣȞȠ ȖȚĮ IJȘȞ ĮıijĮȜȒ ȜİȚIJȠȣȡȖȓĮ. ǹȞIJȚțĮIJĮıIJȐıİȚȢ ȝİ ijĮȚȞȠȝİȞȚțȐ
ȩȝȠȚĮ ĮȞIJĮȜȜĮțIJȚțȐ İȞįȑȤİIJĮȚ ȞĮ ʌȡȠțĮȜȑıȠȣȞ ʌȣȡțĮȖȚȐ,
țȓȞįȣȞȠ ȘȜİțIJȡȠʌȜȘȟȓĮȢ Ȓ ĮȞİʌĮȡțȒ ȜİȚIJȠȣȡȖȓĮ.
x ǺİȕĮȚȦșİȓIJİ ȩIJȚ ȩȜĮ IJĮ ĮȞȠȓȖȝĮIJĮ IJȠȣ İȟȠʌȜȚıȝȠȪ İȓȞĮȚ țȜİȚıIJȐ țĮȚ IJĮ ʌȡȠıIJĮIJİȣIJȚțȐ țĮȜȪȝȝĮIJĮ İȓȞĮȚ ıIJȘ șȑıȘ IJȠȣȢ ʌȡȠțİȚȝȑȞȠȣ ȞĮ ĮʌȠijİȣȤșİȓ
Ƞ țȓȞįȣȞȠȢ ȘȜİțIJȡȠʌȜȘȟȓĮȢ țĮȚ ʌȡȠıȦʌȚțȫȞ IJȡĮȣȝĮIJȚıȝȫȞ, İțIJȩȢ İȐȞ İțIJİȜȠȪȞIJĮȚ İȡȖĮıȓİȢ ıȣȞIJȒȡȘıȘȢ Įʌȩ İȚįȚțİȣȝȑȞȠ ʌȡȠıȦʌȚțȩ.
ȆȇȅǼǿǻȅȆȅǿǾȈǾ: ȆȡȠțİȚȝȑȞȠȣ ȖȚĮ ıȣıțİȣȑȢ ȝİ ȡȠȒ ȡİȣıIJȠȪ, ȩIJĮȞ ȖȚĮ ȠʌȠȚȠȞįȒʌȠIJİ ȜȩȖȠ ʌȡȩțİȚIJĮȚ ȞĮ țȜİȓıȠȣȞ ȠȚ ȕĮȜȕȓįİȢ
İȚıĮȖȦȖȒȢ țĮȚ İȟĮȖȦȖȒȢ țȠȞIJȐ ıIJȚȢ ıȣıțİȣȑȢ, ȠȚ ıȣıțİȣȑȢ ʌȡȑʌİȚ ȞĮ ĮʌȠıIJȡĮȖȖȚıIJȠȪȞ İȞIJİȜȫȢ. Ǿ ȝȘ ıȣȝȝȩȡijȦıȘ ȝʌȠȡİȓ ȞĮ
ʌȡȠțĮȜȑıİȚ șİȡȝȚțȒ įȚĮıIJȠȜȒ IJȠȣ ȣȖȡȠȪ ʌȠȣ ʌİȡȚȑȤȠȣȞ, ȝİ ĮʌȠIJȑȜİıȝĮ ȞĮ ȡĮȖȓıİȚ Ș ıȣıțİȣȒ țĮȚ ȞĮ ʌȡȠțȜȘșȠȪȞ ʌȡȠıȦʌȚțȠȓ
IJȡĮȣȝĮIJȚıȝȠȓ
.
ǼȣȡȦʌĮȧțȒ ȅįȘȖȓĮ ȖȚĮ IJȠȞ İȟȠʌȜȚıȝȩ ȣʌȩ ʌȓİıȘ (PED)
ȀȐșİ İȟȠʌȜȚıȝȩȢ ȣʌȩ ʌȓİıȘ ȝİ İıȦIJİȡȚțȒ ʌȓİıȘ ȐȞȦ IJȠȣ 0,5 bar (g) țĮȚ ȝİȖȑșȠȣȢ ȝİȖĮȜȪIJİȡȠȣ IJȦȞ 25 mm Ȓ IJȘȢ 1 ȓȞIJıĮȢ İȝʌȓʌIJİȚ ıIJȚȢ įȚĮIJȐȟİȚȢ IJȘȢ
İȣȡȦʌĮȧțȒȢ ȅįȘȖȓĮȢ ȖȚĮ IJȠȞ İȟȠʌȜȚıȝȩ ȣʌȩ ʌȓİıȘ (PED).
x ȉȠ țİijȐȜĮȚȠ ȆȡȠįȚĮȖȡĮijȑȢ IJȠȣ ʌĮȡȩȞIJȠȢ İȖȤİȚȡȚįȓȠȣ ʌİȡȚȜĮȝȕȐȞİȚ ȠįȘȖȓİȢ ıȤİIJȚțȐ ȝİ IJȘȞ ȅįȘȖȓĮ PED.
x ȅȚ ȝİIJȡȘIJȑȢ ʌȠȣ ʌİȡȚȖȡȐijȠȞIJĮȚ ıIJȠ ʌĮȡȩȞ İȖȤİȚȡȓįȚȠ ıȣȝȝȠȡijȫȞȠȞIJĮȚ ȝİ IJȘȞ
İȣȡȦʌĮȧțȒ ȅįȘȖȓĮ 97/23/ǼȀ.
x ǵȜĮ IJĮ ȡȠȩȝİIJȡĮ IJȘȢ Brooks Instrument ĮȞȒțȠȣȞ ıIJȘȞ ȠȝȐįĮ ȡİȣıIJȫȞ 1.
x ȂİIJȡȘIJȑȢ ȝİȖĮȜȪIJİȡȠȚ Įʌȩ 25 mm Ȓ 1 ȓȞIJıĮ ıȣȝȝȠȡijȫȞȠȞIJĮȚ ȝİ IJȚȢ țĮIJȘȖȠȡȓİȢ ǿ, ǿǿ țĮȚ ǿǿǿ IJȘȢ ȅįȘȖȓĮȢ PED.
x ȂİIJȡȘIJȑȢ ȝİȖȑșȠȣȢ 25 mm Ȓ 1 ȓȞIJıĮȢ Ȓ țĮȚ ȝȚțȡȩIJİȡȠȚ țĮIJĮıțİȣȐȗȠȞIJĮȚ ıȪȝijȦȞĮ ȝİ IJȠȣȢ țĮȞȩȞİȢ IJȘȢ IJȑȤȞȘȢ (SEP).
ǼȣȡȦʌĮȧțȒ ȅįȘȖȓĮ ȖȚĮ IJȘȞ ȘȜİțIJȡȠȝĮȖȞȘIJȚțȒ ıȣȝȕĮIJȩIJȘIJĮ (EMC)
ȅ (ȘȜİțIJȡȚțȩȢ/ȘȜİțIJȡȠȞȚțȩȢ) İȟȠʌȜȚıȝȩȢ IJȘȢ Brooks Instrument ʌȠȣ ijȑȡİȚ IJȠ ıȒȝĮ CE ȑȤİȚ ȣʌȠıIJİȓ İʌȚIJȣȤȫȢ IJȚȢ įȠțȚȝȑȢ ʌȠȣ ʌȡȠȕȜȑʌȠȣȞ ȠȚ įȚĮIJȐȟİȚȢ
IJȘȢ ȅįȘȖȓĮȢ ȖȚĮ IJȘȞ ȘȜİțIJȡȠȝĮȖȞȘIJȚțȒ ıȣȝȕĮIJȩIJȘIJĮ (ȅįȘȖȓĮ 2004/108/EC ȖȚĮ IJȘȞ EMC).
ȆȐȞIJȦȢ ȤȡİȚȐȗİIJĮȚ ȚįȚĮȓIJİȡȘ ʌȡȠıȠȤȒ ıIJȘȞ İʌȚȜȠȖȒ IJȠȣ țĮȜȦįȓȠȣ ıȒȝĮIJȠȢ ȖȚĮ IJȠȞ İȟȠʌȜȚıȝȩ ʌȠȣ ijȑȡİȚ IJȠ ıȒȝĮ CE.
ȆȠȚȩIJȘIJĮ IJȦȞ țĮȜȦįȓȦȞ ıȒȝĮIJȠȢ, ıIJȣʌȚȠșȜȚʌIJȫȞ țĮȚ ȕȣıȝȐIJȦȞ țĮȜȦįȓȦȞ
:
Ǿ Brooks Instrument ʌȡȠıijȑȡİȚ ȣȥȘȜȒȢ ʌȠȚȩIJȘIJĮȢ țĮȜȫįȚĮ IJĮ ȠʌȠȓĮ ʌȜȘȡȠȪȞ IJȚȢ ʌȡȠįȚĮȖȡĮijȑȢ CE.
Ȉİ ʌİȡȓʌIJȦıȘ ʌĮȡȠȤȒȢ įȚțȠȪ ıĮȢ țĮȜȦįȓȠȣ ıȒȝĮIJȠȢ, ȤȡȘıȚȝȠʌȠȚİȓIJİ țĮȜȫįȚȠ ȝİ ʌȜȒȡȘ șȦȡȐțȚıȘ 100% ıİ ȩȜĮ IJĮ ıȘȝİȓĮ.
ǺȪıȝĮIJĮ IJȪʌȠȣ «D» Ȓ țȣțȜȚțȐ ʌȡȑʌİȚ ȞĮ ȑȤȠȣȞ ȝİIJĮȜȜȚțȒ șȦȡȐțȚıȘ. ȃĮ ȤȡȘıȚȝȠʌȠȚȘșȠȪȞ țĮIJȐ ʌȡȠIJȓȝȘıȘ ȝİIJĮȜȜȚțȠȓ ıIJȣʌȚȠșȜȓʌIJİȢ țĮȜȦįȓȦȞ ȖȚĮ
IJȘ ıIJİȡȑȦıȘ IJȘȢ șȦȡȐțȚıȘȢ.
ȃĮ ıȣȞįİșİȓ Ș
șȦȡȐțȚıȘ IJȠȣ țĮȜȦįȓȠȣ ıIJȠ ȝİIJĮȜȜȚțȩ țȑȜȣijȠȢ Ȓ ıIJȣʌȚȠșȜȓʌIJȘ țĮȚ ȞĮ șȦȡĮțȚıIJİȓ țĮȚ ıIJĮ įȪȠ ȐțȡĮ țĮIJȐ 360 ȝȠȓȡİȢ. Ǿ șȦȡȐțȚıȘ
ʌȡȑʌİȚ ȞĮ IJİȡȝĮIJȓȗİȚ ıİ ȖİȓȦıȘ İįȐijȠȣȢ.
ȉĮ ȕȪıȝĮIJĮ ȐțȡȠȣ IJȘȢ ʌȜĮțȑIJĮȢ İȓȞĮȚ İț țĮIJĮıțİȣȒȢ ȝȘ ȝİIJĮȜȜȚțȐ. ȉĮ ȤȡȘıȚȝȠʌȠȚȠȪȝİȞĮ țĮȜȫįȚĮ ʌȡȑʌİȚ ȞĮ ȑȤȠȣȞ 100% șȦȡȐțȚıȘ ȖȚĮ
ıȣȝȝȩȡijȦıȘ ȝİ IJȘȞ ʌȚıIJȠʌȠȓȘıȘ CE. Ǿ șȦȡȐțȚıȘ ʌȡȑʌİȚ ȞĮ
IJİȡȝĮIJȓȗİȚ ıİ ȖİȓȦıȘ İįȐijȠȣȢ.
īȚĮ IJȘ įȚȐIJĮȟȘ IJȦȞ ĮțȓįȦȞ: ȈȣȝȕȠȣȜİȣșİȓIJİ IJȠ ıȣȞȘȝȝȑȞȠ İȖȤİȚȡȓįȚȠ ȠįȘȖȚȫȞ.
ǾȜİțIJȡȠıIJĮIJȚțȒ İțțȑȞȦıȘ (ESD)
ȆȇȅĭȊȁǹȄǾ: Ǿ ıȣıțİȣȒ ĮȣIJȒ ʌİȡȚȑȤİȚ ȘȜİțIJȡȠȞȚțȐ İȟĮȡIJȒȝĮIJĮ IJĮ ȠʌȠȓĮ ȝʌȠȡȠȪȞ ȞĮ ȣʌȠıIJȠȪȞ İȪțȠȜĮ ȕȜȐȕİȢ Įʌȩ IJȠȞ ıIJĮIJȚțȩ
ȘȜİțIJȡȚıȝȩ. ȆȡȑʌİȚ ȞĮ ĮțȠȜȠȣșȠȪȞIJĮȚ ȠȚ ȠȡșȑȢ įȚĮįȚțĮıȓİȢ ȤİȚȡȚıȝȠȪ țĮIJȐ IJȘȞ ĮijĮȓȡİıȘ, IJȠʌȠșȑIJȘıȘ Ȓ ȐȜȜȠ ȤİȚȡȚıȝȩ IJȦȞ
İıȦIJİȡȚțȫȞ ʌȜĮțİIJȫȞ țĮȚ įȚĮIJȐȟİȦȞ.
ǻȚĮįȚțĮıȓĮ ȤİȚȡȚıȝȠȪ:
1. ĬȑıIJİ IJȘ ıȣıțİȣȒ İțIJȩȢ IJȐıİȦȢ.
2. ĭȡȠȞIJȓıIJİ ȖȚĮ IJȘ ȖİȓȦıȘ IJȠȣ
ʌȡȠıȦʌȚțȠȪ ȝİ ʌİȡȚțȐȡʌȚȠ Ȓ ȐȜȜȠ ĮıijĮȜȑȢ țĮȚ țĮIJȐȜȜȘȜȠ ȝȑıȠ ʌȡȚȞ IJȠʌȠșİIJȒıİIJİ, ĮijĮȚȡȑıİIJİ Ȓ ȡȣșȝȓıİIJİ țȐȡIJİȢ
IJȣʌȦȝȑȞȦȞ țȣțȜȦȝȐIJȦȞ Ȓ ȐȜȜȘ İıȦIJİȡȚțȒ įȚȐIJĮȟȘ.
3. ȅȚ țȐȡIJİȢ IJȣʌȦȝȑȞȦȞ țȣțȜȦȝȐIJȦȞ ʌȡȑʌİȚ ȞĮ ȝİIJĮijȑȡȠȞIJĮȚ ıİ ıȣıțİȣĮıȓĮ Įʌȩ ĮȖȫȖȚȝȠ ȣȜȚțȩ. ȅȚ țȐȡIJİȢ įİȞ ʌȡȑʌİȚ ȞĮ ĮijĮȚȡİșȠȪȞ Įʌȩ IJȠ
ʌȡȠıIJĮIJİȣIJȚțȩ ʌİȡȓȕȜȘȝĮ ʌĮȡȐ ȝȩȞȠ ĮȝȑıȦȢ ʌȡȚȞ Įʌȩ IJȘȞ IJȠʌȠșȑIJȘıȘ.
ȅȚ țȐȡIJİȢ ʌȠȣ ĮijĮȚȡȑșȘțĮȞ ʌȡȑʌİȚ ȞĮ IJȠʌȠșİIJȘșȠȪȞ ĮȝȑıȦȢ ıİ
ʌȡȠıIJĮIJİȣIJȚțȒ ıȣıțİȣĮıȓĮ ȖȚĮ ȝİIJĮijȠȡȐ, ĮʌȠșȒțİȣıȘ Ȓ İʌȚıIJȡȠijȒ ıIJȠ İȡȖȠıIJȐıȚȠ.
ȆĮȡĮIJȘȡȒıİȚȢ:
Ǿ ȪʌĮȡȟȘ İȟĮȡIJȘȝȐIJȦȞ İȣĮȓıșȘIJȦȞ ıIJĮ ijĮȚȞȩȝİȞĮ ESD (ȘȜİțIJȡȠıIJĮIJȚțȒȢ İțțȑȞȦıȘȢ) įİȞ İȓȞĮȚ ȝȠȞĮįȚțȩ ȤĮȡĮțIJȘȡȚıIJȚțȩ IJȘȢ ıȣıțİȣȒȢ ĮȣIJȒȢ. ȅȚ
ʌİȡȚııȩIJİȡİȢ ıȪȖȤȡȠȞİȢ ȘȜİțIJȡȠȞȚțȑȢ ıȣıțİȣȑȢ ʌİȡȚȑȤȠȣȞ İȟĮȡIJȒȝĮIJĮ IJİȤȞȠȜȠȖȓĮȢ ȝİIJĮȜȜȚțȫȞ ȠȟİȚįȓȦȞ (NMOS, SMOS țȐ.). Ǿ ʌİȓȡĮ ȑȤİȚ ĮʌȠįİȓȟİȚ
ȩIJȚ ȝȚĮ
ȝȚțȡȒ ʌȠıȩIJȘIJĮ ıIJĮIJȚțȠȪ ȘȜİțIJȡȚıȝȠȪ Įȡțİȓ ȖȚĮ ȞĮ ʌȡȠțĮȜȑıİȚ ȕȜȐȕİȢ Ȓ ȞĮ țĮIJĮıIJȡȑȥİȚ IJȚȢ ıȣıțİȣȑȢ ĮȣIJȑȢ. ǼȟĮȡIJȒȝĮIJĮ ʌȠȣ ȣʌȑıIJȘıĮȞ
ȕȜȐȕȘ, ĮțȩȝȘ țĮȚ ĮȞ ȝȠȚȐȗȠȣȞ ȞĮ ȜİȚIJȠȣȡȖȠȪȞ ıȦıIJȐ, țȚȞįȣȞİȪȠȣȞ Įʌȩ ʌȡȫȚȝȘ ĮıIJȠȤȓĮ.
Greek
Installation and Operation Manual
X-VA-FC-eng
Part Number: 541B045AAG
December, 2015
A-10
Section A - Essential Instructions
Flow Controllers for Gas and Liquid Service
AlapvetĘ utasítások
ElĘször olvassa el ezeket!
A Brooks Instrument olyan módon tervezi, gyártja és teszteli termékeit, hogy azok megfeleljenek számos belföldi és nemzetközi szabványnak. Ezeket
a berendezéseket megfelelĘen kell telepíteni, üzemeltetni és karbantartani ahhoz, hogy mindenképpen a normál mĦködési tartományuknak
megfelelĘen üzemelhessenek. Az alábbi utasításokat be kell tartani, és be kell építeni a munkavédelmi programba a Brooks Instrument termékeinek
telepítése, üzemeltetése és karbantartása során.
A megfelelĘ teljesítmény garantálása érdekében kizárólag szakképzett személyzet végezze a termék telepítését, üzemeltetését, frissítését,
programozását és karbantartását.
Valamennyi utasítást el kell olvasni a termék telepítése, üzemeltetése és szervizelése elĘtt. Amennyiben ez a kézikönyv nem a megfelelĘ kiadvány, a
hátsó borítón keresse meg a helyi forgalmazót, és további tájékoztatásért lépjen kapcsolatba vele. ėrizze meg ezt a kézikönyvet késĘbbi
tájékoztatásként.
FIGYELEM: Ne mĦködtesse a berendezést az üzemeltetési utasításban megadott üzemi tartományokon túl. Ennek megsértése súlyos
személyi sérüléshez vagy a berendezés meghibásodásához vezethet.
x Amennyiben a gépkönyv utasításai nem egyértelmĦek, lépjen kapcsolatba Brooks Instrument képviselĘjével, hogy tisztázzák a problémát.
x Tartsa be a berendezésen feltüntetett vagy azzal együtt szállított összes figyelmeztetést, felhívást és utasítás.
x A megfelelĘ telepítési utasításban megadott utasítások valamint a hatályos helyi és nemzeti elĘírások szerint telepítse a berendezést. A
termékeket kizárólag a megfelelĘ elektromos és nyomásellátó forrásra kösse.
x Menete: (1) Lassan helyezze nyomás alá a rendszert. Lassanként nyissa ki az üzemi szelepeket az áramlásingadozás elkerülése érdekében. (2)
EllenĘrizze, nincs-e szivárgás az áramlásmérĘ be-, és kimeneti bekötéseinél. Ha nincs szivárgás, töltse fel a rendszert az üzemi nyomásra.
x Szervizelés elĘtt mindenképpen ellenĘrizze, hogy az üzemi vezeték nincs-e nyomás alatt. Amennyiben cserealkatrészekre van szükség,
mindenképpen szakképzett személynek kell kezelnie a Brooks Instrument által meghatározott cserealkatrészeket. A nem engedélyezett
alkatrészek és tevékenységek befolyásolhatják a termék teljesítményét, illetve veszélyeztethetik a biztonságos üzemeltetést. A pusztán hasonló
alkatrészekkel történĘ helyettesítés tüzet, áramütésveszélyt vagy elégtelen mĦködést eredményezhet.
x A berendezés összes ajtaja mindenképpen legyen zárva, a védĘburkolatok pedig legyenek a helyükön az áramütés és a személyi sérülések
elkerülése érdekében, kivéve, ha szakképzett szakember végez rajta karbantartási munkákat.
FIGYELEM: Folyadékot áramoltató berendezések esetében, ha bármilyen okból el kell zárni a berendezés melletti ki-, és belépĘ
szelepeket, a berendezést teljesen le kell üríteni. Ennek elmulasztása a folyadék hĘtágulását okozhatja, ami károsíthatja a berendezést, és
személyi sérüléshez vezethet.
Nyomástartó berendezésekre vonatkozó európai irányelv (PED)
Minden 0,5 bar-nál (g) magasabb belsĘ nyomású és 25 mm-nél vagy 1 hüvelyknél nagyobb nyomástartó berendezés a nyomástartó berendezésekre
vonatkozó európai irányelv (PED) hatálya alá tartozik.
x A gépkönyv „MĦszaki adatok” fejezete tartalmaz a PED irányelvre vonatkozó utasításokat.
x A gépkönyvben megadott mérĘeszközök megfelelnek a 97/23/EK EU irányelvnek.
x Minden Brooks átfolyásmérĘ az 1-es folyadékcsoportba tartozik.
x A 25 mm-nél vagy 1 hüvelyknél nagyobb mérĘeszközök megfelelnek a PED I, II, vagy III kategóriának.
x A 25 mm-es illetve 1 hüvelykes vagy kisebb mérĘeszközök az elfogadott mérnöki gyakorlatot (SEP) követik.
Elektromágneses kompatibilitásra vonatkozó európai irányelv (EMC)
A Brooks Instrument CE jelölést kiérdemelt (elektromos/elektronikus) berendezései sikeresen teljesítették az elektromágneses kompatibilitási
követelményeket (2004/108/EC sz. EMC irányelv) vizsgáló teszteket.
Ugyanakkor különös figyelmet kell fordítani a CE jelölésĦ berendezésekhez felhasznált jelkábelek kiválasztására.
A jelkábelek, kábelösszekötĘk, csatlakozók minĘsége:
A Brooks Insturment magas minĘségĦ kábeleket kínál, melyek megfelelnek a CE minĘsítés követelményeinek.
Amennyiben saját jelkábelt alkalmaznak, olyat kell választani, amely 100%-os árnyékolással, teljes mértékben szĦrt.
A „D” vagy „kör alakú” csatlakozóknak fémárnyékolóval árnyékoltnak kell lennie. Szükség esetén fém kábelösszekötĘket kell alkalmazni a kábelszĦrĘ
rögzítésére.
A kábelszĦrĘt a fém házhoz vagy hüvelyhez kell csatlakoztatni és mindkét felén 360°-ban le kell árnyékolni. Az árnyékolásnak földelésben kell
végzĘdnie.
A kártyákhoz tartozó csatlakozók szabványosan nem fémesek. Az alkalmazott kábeleknek 100%-és árnyékolással szĦrteknek kell lenniük, hogy
megfeleljenek a CE minĘsítésnek.
Az árnyékolásnak földelésben kell végzĘdnie.
ÉrintkezĘ konfiguráció: Lásd a mellékelt kezelési utasítást.
Elektrosztatikus kisülés (ESD)
VIGYÁZAT: A készülék olyan alkatrészeket tartalmaz, melyek hajlamosak a sztatikus elektromosság okozta károsodásra. Be kell tartani
a megfelelĘ eljárásokat a belsĘ áramköri kártyák és eszközök eltávolítása, behelyezése vagy egyéb kezelése során.
Kezelési eljárás:
1. A berendezést áramtalanítani kell.
2. A személyt földelni kell csuklópánttal vagy egyéb biztonságos és a célra alkalmas eszközzel, mielĘtt áramköri kártyát vagy egyéb belsĘ eszközt
telepítene, venne ki, vagy állítana be.
3. A nyomtatott áramköri kártyákat vezetĘképes csomagolásban kell szállítani. A kártyák kizárólag közvetlenül a behelyezés elĘtt vehetĘk ki a
védĘburkolatból. A kiszerelt kártyát haladéktalanul el kell helyezni a mozgatásra, raktározásra vagy a gyári visszaszállításra szolgáló
védĘcsomagolásba.
Megjegyzések:
Nem egyedi jelenség, hogy a készülékben elektrosztatikus kisülésre (ESD) érzékeny alkatrészek találhatók. A legtöbb
korszerĦ elektronikus
eszközben fémoxid technológiás alkatrészek (NMOS, SMOS stb.) találhatók. A tapasztalatok azt igazolják, hogy még
kis mértékĦ sztatikus elektromosság is károsíthatja, vagy tönkreteheti ezeket az eszközöket. A károsodott alkatrészek,
még ha látszólag megfelelĘen mĦködnek is, kezdĘdĘ hibára utalnak.
Hungarian
A-11
Section A - Essential Instructions
Installation and Operation Manual
X-VA-FC-eng
Part Number: 541B045AAG
December, 2015
Flow Controllers for Gas and Liquid Service
Istruzioni fondamentali
Leggerle subito!
La Brooks Instrument progetta, fabbrica e collauda i propri prodotti in maniera tale che siano conformi ai vari standard nazionali ed internazionali. Tali
apparecchiature devono essere installate, messe in esercizio e tenute in manutenzione in maniera adeguata affinché operino in conformità alle loro normali
specifiche di funzionamento. Le seguenti istruzioni devono essere rispettate ed inserite nel programma di tutela sul lavoro durante l’installazione, il
funzionamento e la manutenzione dei prodotti Brooks Instrument.
x Per garantire un adeguato rendimento l'installazione, il funzionamento, l’aggiornamento, la programmazione e la manutenzione del prodotto devono
essere eseguiti esclusivamente da personale specializzato.
x Leggere tutte le istruzioni prima dell’installazione, utilizzo e manutenzione del prodotto. Se questo manuale non è quello relativo al Vostro prodotto,
cercare sul retro della copertina il distributore locale e contattarlo per ulteriori informazioni. Conservare il presente manuale per future consultazioni.
ATTENZIONE: Non utilizzare questo strumento in condizioni che eccedono le specifiche riportate nel Manuale d’Uso. L’inosservanza può
causare gravi lesioni alle persone e/o danni all’apparecchiatura.
x Qualora le istruzioni del manuale non siano chiare, contattare un rappresentante della Brooks Instrument per chiarire il problema.
x Rispettare tutti gli avvisi, le istruzioni e gli avvertimenti riportati sull’apparecchiatura o forniti insieme ad essa.
x Installare l’apparecchiatura in base alle istruzioni riportate nel Manuale d’Uso e alle prescrizioni locali e nazionali in vigore. Collegare i prodotti
esclusivamente ad un’adeguata sorgente di pressione ed alimentazione elettrica.
x Procedimento: (1) mettere lentamente sotto pressione il sistema. Aprire lentamente le valvole di servizio per evitare l’oscillazione del flusso. (2) Controllare
che non ci siano perdite nei punti di connessione in entrata e in uscita del misuratore di flusso. Se non ci sono perdite, caricare il sistema alla pressione
d’esercizio.
x Prima di effettuare manutenzione controllare che la linea di processo non sia sotto pressione. Se avete bisogno di pezzi di ricambio, il personale
specializzato deve usare i pezzi di ricambio definiti dalla Brooks Instrument. Attività e pezzi di ricambio non autorizzati possono influire sul rendimento del
prodotto e comprometterne il funzionamento in sicurezza. La sostituzione con pezzi di ricambio non originali può causare incendi, pericolo di scosse
elettriche o funzionamento improprio.
x Tutti gli sportelli dell’impianto devono essere chiusi, le cappe di protezione devono essere al loro posto per evitare scosse elettriche e lesioni personali,
tranne quando il personale specializzato esegue lavori di manutenzione.
ATTENZIONE: In caso di apparecchiature in cui scorre un liquido, se per qualsiasi motivo bisogna chiudere le valvole d’entrata e d’uscita
accanto all’apparecchiatura, allora si deve svuotare completamente l’apparecchiatura. L’inosservanza può causare la dilatazione termica del liquido
che può danneggiare l’apparecchiatura e provocare lesioni alle persone.
Direttiva europea relativa alle apparecchiature a pressione (PED)
Ogni apparecchiatura a pressione con pressione interna maggiore di 0,5 bar (g) e più grande di 25 mm o di 1 pollice ricade nell’ambito della Direttiva Europea
relativa alle apparecchiature a pressione (PED).
x Il capitolo „Dati tecnici” del manuale contiene le disposizioni relative alla direttiva PED.
x Gli strumenti di misura descritti nel presente manuale sono conformi alla Direttiva UE 97/23/CE.
x Ogni flussimetro Brooks appartiene al gruppo di fluidi 1.
x Gli strumenti di misura maggiori di 25 mm o di 1 pollice sono conformi alla categoria I, II o III della PED.
x
Gli strumenti di misurazione minori di 25 mm o di 1 pollice rientrano nella categoria SEP (Sound Engineering Practice).
Direttiva europea relativa alla compatibilità elettromagnetica (EMC)
Le apparecchiature (elettriche/elettroniche) Brooks Instrument dispongono del marchio CE ed hanno superato positivamente i test per i requisiti di compatibilità
elettromagnetica (Direttiva EMC 2004/108/EC).
In ogni caso bisogna prestare particolare attenzione alla scelta dei cavi di segnale utilizzati per le apparecchiature con marchio CE.
Qualità dei cavi di segnale, dei pressacavi e dei connettori:
La Brooks Instrument offre cavi d’alta qualità conformi ai requisiti della certificazione CE.
Qualora vengano utilizzati cavi di segnale propri, devono essere scelti con schermatura al 100% e interamente filtrati.
I connettori „D” o „rotondi” devono essere schermati con schermatura metallica. In caso di necessità bisogna utilizzare pressacavi metallici di collegamento per
fissare la schermatura del cavo.
La schermatura del cavo deve far contatto col guscio metallico o col pressacavo; il cavo deve essere schermato su entrambi i lati a 360°. La schermatura deve
essere effettuata con messa a terra.
I connettori Card Edge normalmente non sono di metallo. I cavi utilizzati devono essere filtrati con schermatura al 100% per essere conformi alla marcatura
CE.
La schermatura deve essere effettuata con messa a terra.
Configurazione pin: Vedi Manuale d’uso allegato.
Scarica elettrostatica (ESD)
ATTENZIONE: Il dispositivo contiene componenti elettronici che possono essere danneggiati da elettricità statica. Bisogna rispettare le
adeguate procedure durante la rimozione, l’installazione o altra manovra delle schede del circuito elettrico interno.
Procedura di manovra:
1. Togliere alimentazione elettrica all’apparecchiatura.
2. La persona deve essere collegata a terra con una cerniera o con altri strumenti di sicurezza e adeguati allo scopo prima di installare, togliere o impostare
la scheda del circuito elettrico o altri dispositivi interni.
3. Le schede del circuito stampato devono essere spedite in contenitori conduttivi. Le schede devono essere tolte dal rivestimento protettivo esclusivamente
prima dell’installazione. Le schede confezionate devono essere collocate immediatamente nell’imballaggio protettivo per la movimentazione,
l’immagazzinamento o resa alla fabbrica.
Note:
È un fenomeno comune che nei dispositivi di questo tipo si trovino componenti sensibili alla scarica elettrostatica (ESD). Nella maggior parte degli strumenti
elettronici moderni si trovano componenti tecnologici metallo-ossido (NMOS, SMOS, ecc.). Le esperienze dimostrano che l’elettrostaticità anche in piccola
misura può danneggiare o rovinare gli strumenti. I componenti danneggiati, anche se all’apparenza funzionano correttamente, potrebbero manifestare il difetto
rapidamente.
Italian
Installation and Operation Manual
X-VA-FC-eng
Part Number: 541B045AAG
December, 2015
A-12
Section A - Essential Instructions
Flow Controllers for Gas and Liquid Service
SvarƯga instrukcija
Pirms turpinƗt izlasiet!
„Brooks Instrument” projektƝ, ražo un pƗrbauda savus ražojumus atbilstoši daudziem nacionƗlajiem un starptautiskajiem standartiem. Lai nodrošinƗtu šo
izstrƗdƗjumu turpmƗku darbƯbu atbilstoši noteiktajiem parametriem, tie ir pareizi jƗuzstƗda, jƗlieto un jƗapkopj. UzstƗdot, lietojot „Brooks Instrument”
izstrƗdƗjumus un veicot to apkopi, ir jƗievƝro šie norƗdƯjumi un jƗiekƺauj tie jnjsu drošƯbas programmƗ.
x Lai nodrošinƗtu pienƗcƯgu izstrƗdƗjuma sniegumu, izstrƗdƗjuma uzstƗdƯšanu, lietošanu, atjauninƗšanu, programmƝšanu un apkopi uzticiet veikt tikai
kvalificƝtam personƗlam.
x Pirms izstrƗdƗjuma uzstƗdƯšanas, lietošanas un apkalpošanas izlasiet visus norƗdƯjumus. Ja šƯ instrukciju rokasgrƗmata nav pareizƗ, izstrƗdƗjumam
atbilstošƗ rokasgrƗmata, lnjdzu skat. aizmugurƝjo vƗku, kur ir sniegta vietƝjƗ tirdzniecƯbas biroja kontaktinformƗcija.
BRƮDINƖJUMS! Nelietot instrumentu Ɨrpus Instrukciju un lietošanas rokasgrƗmatƗ norƗdƯtajiem parametriem. ŠƯ brƯdinƗjuma
neievƝrošanas rezultƗtƗ var rasties traumas un / vai aprƯkojuma bojƗjumi.
x Ja jnjs nesaprotat kƗdu no instrukcijƗm, sazinieties ar „Brooks Instrument” pƗrstƗvi un lnjdziet izskaidrot to.
x IevƝrojiet visus brƯdinƗjumus, piesardzƯbas mƝrus un instrukcijas, kas norƗdƯti uz izstrƗdƗjuma vai piegƗdƗti kopƗ ar to.
x UzstƗdiet aprƯkojumu tƗ, kƗ tas norƗdƯts attiecƯgajƗ instrukciju rokasgrƗmatƗ iekƺautajƗ uzstƗdƯšanas instrukcijƗ un atbilstoši piemƝrojamajƗm vietƝjƗm
un nacionƗlajƗm normƗm. Pievienojiet visus izstrƗdƗjumus pareiziem elektriskajiem un spiediena avotiem.
x Lietošana: (1) LƝnƗm uzsƗciet plnjsmu sistƝmƗ. Lai izvairƯtos no straujiem plnjsmas kƗpumiem, lƝnƗm atveriet procesa vƗrstus. (2) PƗrbaudiet, vai nav
noplnjdes ap plnjsmas mƝrƯtƗja ieplnjdes un izplnjdes savienojumiem. Ja noplnjdes nav, uzstƗdiet sistƝmƗ darba spiedienu.
x PƗrliecinieties par to, lai pirms instrumenta tehniskƗs apkopes bnjtu likvidƝts procesa lƯnijas spiediens. Ja ir nepieciešams veikt kƗdu daƺu nomaiƼu,
nodrošiniet, lai tiktu izmantotas „Brooks Instrument” norƗdƯtƗs daƺas un daƺu nomaiƼu veiktu kvalificƝts personƗls. Neatƺautu daƺu un procednjru
izmantošana var ietekmƝs ražojuma sniegumu un samazinƗt procesa drošƯbu. LƯdzƯgu, bet ne identisku daƺu nomaiƼas lietošana var izraisƯt
ugunsgrƝka, elektrisko traucƝjumu riskus un nepareizu izstrƗdƗjuma darbƯbu.
x Nodrošiniet, lai bnjtu aizvƝrtas visas durvis un bnjtu pareizi uzstƗdƯti visi aizsargpƗrsegumi, tƗdƝjƗdi novƝršot elektrošoka un traumu risku. IzƼƝmums ir
gadƯjumi, kad kvalificƝts personƗls veic ražojuma apkopi.
BRƮDINƖJUMS! Ja šƷidrƗs plnjsmas ierƯþu tuvumƗ esošos ieplnjdes un izplnjdes vƗrstus kƗda iemesla dƝƺ ir jƗaizver, no ierƯcƝm ir jƗizlaiž
viss šƷidrums. PretƝjƗ gadƯjumƗ šƷidrums var termiski izplesties, pƗrraut ierƯci un radƯt traumas.
Eiropas spiedieniekƗrtu direktƯva (PED)
Uz visƗm spiedieniekƗrtƗm, kuru iekšƝjais spriegums pƗrsniedz 0,5 bar (g) un ir lielƗkas par 25 mm jeb 1” (collu), attiecas Eiropas spiedieniekƗrtu direktƯva
(PED).
x ŠƯs rokasgrƗmatas tehnisko parametru nodaƺƗ ir sniegtas a PED DirektƯvu saistƯtƗs instrukcijas.
x ŠajƗ rokasgrƗmatƗ aprakstƯtie mƝrƯtƗji atbilst EN DirektƯvas 97/23/EK prasƯbƗm.
x Visi „Brooks Instrument” plnjsmas mƝrƯtƗji ietilpst 1. šƷidrumu grupƗ.
x Uz 25 mm jeb 1” (collu) maziem un mazƗkiem mƝrƯtƗjiem attiecas labas inženierijas prakse (SEP).
x 25 mm jeb 1” (collu) mazi vai mazƗki mƝrƯtƗji atbilst PED kategorijai I, II vai III.
Eiropas elektromagnƝtiskƗs savietojamƯbas direktƯva (EMS)
Brooks Instrument” (elektriskƗs / elektroniskƗs) iekƗrtas ar CE zƯmi ir izturƝjušas pƗrbaudi un atzƯtas par atbilstošƗm Eiropas elektromagnƝtiskƗs
savietojamƯbas direktƯvas (EMS) prasƯbƗm (EMS 2004/108/EC)
TomƝr, izvƝloties signƗlkabeli, kas tiks lietots kopƗ ar CE marƷƝjuma iekƗrtu, ir jƗievƝro Ưpaša uzmanƯbaSignƗlkabeƺa, kabeƺa blƯvslƝgu un savienotƗju
kvalitƗte:
„Brooks Instrument” piegƗdƗ augstas kvalitƗtes kabeƺus, kas atbilst CE sertifikƗcijas tehniskajiem parametriem.
Ja jnjs lietojat pats savu signƗlkabeli, tam ir jƗbnjt pilnƯbƗ, 100% ekranizƝtam.
„D” un „apaƺƗ” tipa savienotƗjiem ir jƗbnjt aprƯkotiem ar metƗla ekranizƝjumu. Ja nepieciešams, ir jƗizmanto metƗla blƯvslƝgi ar kabeƺa ekranizƝjuma skavojumu.
Kabeƺa ekranizƝjumam ir jƗbnjt savienotam ar metƗla apvalku un abƗs pusƝs aizsargƗtam 360 grƗdu diapazonƗ.
EkranizƝjumam ir jƗbeidzas pie iezemƝjuma.
„Card Edge” savienotƗji standarta izpildƯjumƗ ir nemetƗla. Kabeƺiem ir jƗbnjt pƗrklƗtiem ar 100% ekranizƝjumu, lai tie atbilstu CE sertifikƗcijas prasƯbƗm.
EkranizƝjumam ir jƗbeidzas pie iezemƝjuma.
AttiecƯbƗ uz tapu konfigurƗciju: skat. pievienoto instrukciju rokasgrƗmatu.
ESD (elektrostatiskƗ izlƗde)
IEVƜROT PIESARDZƮBU! Šis instruments satur elektriskos komponentus, kas ir jutƯgi pret statisko elektrƯbu. IzƼemot un uzstƗdot iekšƝjƗs
ƷƝdes plates un ierƯces vai kƗ citƗdi darbojoties ar tƗm, ir jƗievƝro noteikta darba kƗrtƯba.
Darba kƗrtƯba:
1. IekƗrta jƗatslƝdz no barošanas.
2. Pirms jebkƗdas drukƗtas shƝmas kartes vai citas iekšƝjƗs ierƯces uzstƗdƯšanas, izƼemšanas vai regulƝšanas personƗlam, kas veiks šos darbus, ir jƗbnjt
iezemƝtam, piem., izmantojot aproces vai citus drošus, piemƝrotus lƯdzekƺus.
3. DrukƗtƗs shƝmas kartes ir jƗtransportƝ vadošƗ iepakojumƗ. PlƗksnes no aizsargkorpusa drƯkst izƼemt tikai tieši pirms uzstƗdƯšanas. TransportƝjot,
uzglabƗjot vai atgriežot rnjpnƯcƗ no izƼemtƗs plƗksnes ir nekavƝjoties jƗievieto aizsargiepakojumƗ.
KomentƗri
Instruments nav unikƗls tajƗ aspektƗ, ka tas satur pret ESD (elektrostatisko izlƗdi) jutƯgus komponentus. Vairums mnjsdienu elektroiekƗrtu satur komponentus,
kuru ražošanƗ izmantota metƗla oksƯdu tehnoloƧijas (NMOS, SMOS u.c.). Pieredze rƗda, ka pat neliels daudzums statiskƗs elektrƯbas var nodarƯt bojƗjumus
šƗdƗm ierƯcƝm vai pilnƯbƗ sabojƗt tƗs. BojƗtie komponenti pat tad, ja tie šƷietami darbojas pareizi, ir pakƺauti ƗtrƗkai atteicei.
Latvian
A-13
Section A - Essential Instructions
Installation and Operation Manual
X-VA-FC-eng
Part Number: 541B045AAG
December, 2015
Flow Controllers for Gas and Liquid Service
Pagrindinơs instrukcijos
Perskaitykite prieš tĊsdami!
„Brooks Instrument“ projektuoja, gamina ir išbando savo gaminius, kad jie atitiktǐ Ƴvairius nacionalinius ir tarptautinius standartus. Šie gaminiai turi bnjti tinkamai
montuojami, eksploatuojami ir prižinjrimi, kad ir toliau veiktǐ pagal jiems bnjdingus techninius parametrus. Toliau pateiktǐ nurodymǐ reikia laikytis ir Ƴtraukti juos Ƴ
saugos programą montuojant, eksploatuojant ir prižinjrint „Brooks Instrument“ produktus.
x Siekiant užtikrinti tinkamą veikimą, montuoti, eksploatuoti, naujinti, programuoti ir prižinjrơti gaminƳ turi tik kvalifikuoti darbuotojai.
x Perskaitykite visus nurodymus prieš montuodami, eksploatuodami ir prižinjrơdami gaminƳ. Jei gavote netinkamą instrukciją, galiniame jos viršelyje žinjrơkite
vietinơs prekybos atstovybơs kontaktinĊ informaciją. Išsaugokite šią instrukciją pasižinjrơjimui ateityje.
ƲSPƠJIMAS: nenaudokite šio prietaiso viršydami instrukcijoje ir eksploatacijos vadove nurodytus techninius duomenis. Nesilaikydami šio
Ƴspơjimo galite sunkiai susižeisti ir (arba) sugadinti Ƴrangą.
x Jei nesuprantate kokiǐ nors nurodymǐ, kreipkitơs Ƴ „Brooks Instrument“ atstovą, kad paaiškintǐ.
x Paisykite visǐ Ƴspơjimo, perspơjimǐ ir nurodymǐ, pažymơtǐ ant gaminio arba pateiktǐ su juo.
x Ʋrangą montuokite taip, kaip nurodyta atitinkamos instrukcijos montavimo nurodymuose arba taikomuose vietiniuose ar nacionaliniuose kodeksuose. Visus
gaminius junkite prie tinkamǐ elektros ir slơgio šaltiniǐ.
x Eksploatacija: (1) lơtai Ƴjunkite srautą Ƴ sistemą. Lơtai atidarykite proceso vožtuvus, kad išvengtumơte srauto antplnjdžiǐ. (2) Patikrinkite, ar nơra nuotơkiǐ
aplink srauto matuoklio Ƴleidimo ir išleidimo jungtis. Jei nuotơkiǐ nơra, sukurkite sistemoje darbinƳ slơg
Ƴ.
x Prieš atlikdami priežinjros darbus bnjtinai pašalinkite slơgƳ proceso linijoje. Jei reikia pakeisti dalis, užtikrinkite, kad kvalifikuoti darbuotojai naudotǐ „Brooks
Instrument“ nurodytas pakaitines dalis. Netinkamos dalys ir procednjros gali pakenkti gaminio veikimui ir kelti pavojǐ saugiai jnjsǐ proceso eksploatacijai. Tik
panašiai atrodantys pakaitalai gali sąlygoti gaisrą, elektros pavojus ar netinkamą veikimą.
x Užtikrinkite, kad visos Ƴrangos durelơs bnjtǐ uždarytos, o apsauginiai dangþiai uždơti, kad išvengtumơte elektros smnjgio ir sužeidimǐ, išskyrus kai kvalifikuoti
darbuotojai atlieka priežinjros darbus.
ƲSPƠJIMAS: naudojant skysto srauto Ƴrenginius, jei dơl kokios nors priežasties prireikia uždaryti šalia Ƴrenginio esanþius Ƴleidimo ir išleidimo
vožtuvus, iš Ƴrenginio reikia išleisti visą skystƳ. To nepadarius galimas šiluminis skysþio plơtimasis, galintis sugadinti ƳrenginƳ ir sužeisti žmonơs.
Europos slơginơs Ƴrangos direktyva (PED)
Visa slơginơ Ƴranga, kurios vidinis slơgis didesnis nei 0,5 bar (g), o dydis didesnis nei 25 mm arba 1 colis, yra reglamentuojama slơginơs Ƴrangos direktyvos
(PED).
x Šios instrukcijos dalyje „Techniniai duomenys“ pateikiami nurodymai, susijĊ su PED direktyva.
x Šioje instrukcijoje aprašyti matuokliai atitinka Europos Sąjungos direktyvą 97/23/EB.
x Visi „Brooks Instrument“ srauto matuokliai priklauso 1 skysþiǐ grupei.
x Didesni nei 25 mm arba 1 colis matuokliai atitinka PED I, II arba III kategoriją.
x 25 mm arba 1 colio ar mažesni matuokliai atitinka tinkamą inžinerijos praktiką (SEP).
Europoje taikomi elektromagnetinio suderinamumo (EMC) reikalavimai
CE ženklu pažymơta „Brooks Instrument“ (elektrinơ / elektroninơ) Ƴranga buvo sơkmingai išbandyta pagal elektromagnetinio suderinamumo reikalavimus (EMC
direktyvą 2004/108/EC).
Bet reikia ypatingo dơmesio renkantis signalizavimo kabelƳ, kuris bus naudojamas su CE ženklu pažymơta Ƴranga.
Signalizavimo kabelio, kabeliǐ riebokšliǐ ir jungþiǐ kokybơ:
„Brooks Instrument“ tiekia kokybiškus kabelius, kurie atitinka CE sertifikavimo specifikacijas.
Jei naudojate savo signalizavimo kabelƳ, jis turi bnjti visiškai ir visas ekranuotas 100 % ekranu.
Naudojamos „D“ arba „apskrito“ tipo jungtys turi bnjti ekranuotos metaliniu ekranu. Jei taikoma, reikia naudoti metalinius kabeliǐ riebokšlius, užtikrinanþius kabelio
ekrano suspaudimą.
Kabelio ekraną reikia jungti prie metalinio apvalkalo ar riebokšlio ir ekranuoti abiejuose galuose 360 laipsniǐ.
Ekranas turi baigtis Ƴžeminimu.
Standartinơs kraštinơs jungtys yra ne metalinơs. Naudojami kabeliai turi bnjti ekranuoti 100 % ekranu, kad atitiktǐ CE sertifikavimą. Ekranas turi baigtis Ƴžeminimu.
Keturiǐ kontaktǐ konfignjracija: žr. pridơtą instrukciją.
ESD (elektrostatinis išlydis)
PERSPƠJIMAS: šiame prietaise yra elektroniniǐ komponentǐ, kuriuos gali sugadinti statinơ elektra. Išimant ar Ƴdedant vidines spausdintines
plokštes ar Ƴrenginius, arba atliekant su jomis kitus darbus, reikia laikytis tinkamǐ darbo procednjrǐ.
Darbo procednjra:
1. Atjunkite Ƴrenginio maitinimą.
2. Darbuotojai turi pasirnjpinti Ƴžeminimu naudodami riešo juostelĊ ar kitas saugias tinkamas priemones prieš Ƴdơdami, išimdami ar reguliuodami bet kokią
spausdintinơs plokštơs kortelĊ ar kitą vidinƳ komponentą.
3. Spausdintinơs plokštơs korteles reikia transportuoti laidžiame konteineryje. Neleidžiama išimti plokštơs iš apsauginio dơklo, nebent prieš pat Ƴdơjimą. Išimtas
plokštes reikia nedelsiant Ƴdơti Ƴ apsauginƳ konteinerƳ transportavimui ar saugojimui arba grąžinti Ƴ gamyklą.
Pastabos
Šis instrumentas nơra unikalus dơl jame esanþiǐ ESD (elektrostatiniam išlydžiui) jautriǐ komponentǐ
. Daugelyje šiuolaikiniǐ
elektroniniǐ gaminiǐ yra komponentǐ,
kuriuose naudojama metalo oksidǐ technologija (NMOS, SMOS ir pan.). Patirtis rodo, kad net ir mažas statinơs elektros kiekis gali pakenkti tokiems gaminiams
ar juos sugadinti. Sugadinti komponentai, net jei atrodo, kad jie veikia tinkamai, anksti nustoja veikti.
Lithuanian
Installation and Operation Manual
X-VA-FC-eng
Part Number: 541B045AAG
December, 2015
A-14
Section A - Essential Instructions
Flow Controllers for Gas and Liquid Service
Zalecenia wstĊpne
Prosimy przeczytaü przed rozpoczĊciem uĪytkowania!
Brooks Instrument projektuje, wytwarza i testuje swoje produkty tak, aby speániaáy wymagania licznych norm krajowych i miĊdzynarodowych. Te
produkty muszą byü poprawnie instalowane, obsáugiwane oraz konserwowane, aby zapewniü ich prawidáowe dziaáanie zgodnie ze specyfikacją
techniczną. Podczas instalowania, obsáugiwania i konserwowania produktów firmy Brooks Instrument naleĪy przestrzegaü nastĊpujących zaleceĔ:
x Aby zapewniü wáaĞciwe dziaáanie sprzĊtu, instalacja, obsáuga, aktualizacje, programowanie i konserwacja powinny byü wykonywane przez
przeszkolony personel.
x Przed instalacją, obsáugą i czynnoĞciami serwisowymi naleĪy zapoznaü siĊ ze wszystkimi zaleceniami producenta. Aby uzyskaü instrukcjĊ
obsáugi odpowiednią dla danego sprzĊtu naleĪy skontaktowaü siĊ z lokalnym przedstawicielem handlowym producenta. InstrukcjĊ obsáugi
naleĪy zachowaü do póĨniejszego uĪycia.
OSTRZEĩENIE: Nie wolno przekraczaü podanych w instrukcji zakresów dziaáania urządzenia. Nieprzestrzeganie tego zalecenia
moĪe doprowadziü do powaĪnego zagroĪenia Īycia lub zdrowia personelu i / lub uszkodzenia sprzĊtu.
x JeĪeli jakieĞ zalecenia w instrukcji obsáugi urządzenia są niezrozumiaáe, prosimy o skontaktowanie siĊ z przedstawicielem firmy Brooks
Instrument, aby wyjaĞniü problem.
x NaleĪy postĊpowaü biorąc pod uwagĊ wszystkie ostrzeĪenia, uwagi i zalecenia umieszczone na produkcie lub doáączone do niego.
x InstalacjĊ urządzenia naleĪy przeprowadziü zgodnie z zaleceniami zawartymi w instrukcji instalacji oraz z obowiązującymi lokalnymi i narodowymi
oznaczeniami. Wszystkie urządzenia moĪna podáączaü wyáącznie do odpowiednich Ĩródeá energii elektrycznej oraz ciĞnienia.
x Pierwsze czynnoĞci obsáugowe: (1) NaleĪy powoli wáą
czyü przepáyw w instalacji. NastĊpnie powoli otworzyü zawory robocze tak, aby uniknąü
wahaĔ przepáywu. (2) NaleĪy teraz sprawdziü, czy nie wystĊpują nieszczelnoĞci przy podáączeniach wejĞciowym i wyjĞciowym miernika
przepáywu. JeĪeli nie ma Īadnych nieszczelnoĞci, moĪna zwiĊkszyü ciĞnienie w instalacji do wartoĞci ciĞnienia roboczego.
x Przed przystąpieniem do czynnoĞci serwisowych naleĪy upewniü siĊ, Īe ciĞnienie robocze jest odáączone. JeĪeli konieczna jest wymiana czĊĞci
zamiennych, naleĪy zawsze stosowaü czĊĞci zamienne specyfikowane przez firmĊ Brooks Instrument a czynnoĞci ich wymiany powinien w
kaĪdym przypadku dokonywaü przeszkolony personel. Stosowanie nieautoryzowanych czĊĞci i procedur serwisowych moĪe niekorzystnie
wpáynąü na dziaá
anie produktu oraz zagroziü bezpieczeĔstwu instalacji. Korzystanie z podobnie wyglądających zamienników moĪe doprowadziü
do poĪaru, poraĪenia prądem lub nieprawidáowego dziaáania urządzenia.
x NaleĪy upewniü siĊ, Īe wszystkie otwory urządzenia są zamkniĊte a osáony umocowane na swoich miejscach, aby zapobiec obraĪeniom ciaáa lub
poraĪeniu prądem personelu. Zalecenie to nie dotyczy przeszkolonego pracownika wykonującego prace serwisowe lub konserwacyjne.
OSTRZEĩENIE: W przypadku mierników przepáywu cieczy, jeĪeli znajdujące siĊ na nich zawory wejĞciowe i wyjĞciowe mają byü z
jakiegoĞ powodu zamkniĊte, to urządzenie musi zostaü caákowicie opróĪnione z ciekáego medium. Niedopeánienie tego zalecenia
moĪe doprowadziü do termicznego zwiĊkszenia objĊtoĞci cieczy, co z kolei moĪe spowodowaü uszkodzenie urządzenia i obraĪenia
personelu.
Europejska dyrektywa dotycząca urządzeĔ ciĞnieniowych (PED)
Wszystkie urządzenia ciĞnieniowe pracujące przy ciĞnieniu wewnĊtrznym wzglĊdnym wiĊkszym niĪ 0.5 bara i wielkoĞci powyĪej 25 mm lub 1 cala
podlegają dyrektywie europejskiej dotyczącej urządzeĔ ciĞnieniowych (PED).
x Rozdziaá „Specyfikacja techniczna” niniejszej instrukcji zawiera zalecenia dotyczące dyrektywy PED.
x Mierniki opisane w tej instrukcji są zgodne z dyrektywą EN 97/23/EC.
x Wszystkie mierniki przepáywu firmy Brooks Instrument naleĪą do 1-szej grupy cieczy.
x Urządzenia pomiarowe o wielkoĞci powyĪej 25 mm lub 1 cala naleĪą do kategorii I, II lub III dyrektywy PED.
x Urządzenia pomiarowe o wielkoĞci 25 mm lub 1 cala lub mniejsze podlegają zaleceniom „Uznanej Praktyki InĪynierskiej” (SEP).
Europejska dyrektywa dotycząca kompatybilnoĞci elektromagnetycznej (EMC)
Urządzenia elektryczne / elektroniczne firmy Brooks Instrument posiadające oznaczenie CE, przeszáy pozytywnie testy pod kątem speániania przez
nich wymogów kompatybilnoĞci elektromagnetycznej (Dyrektywa EMC 2004/108/EC).
JednakĪe szczególną uwagĊ naleĪy poĞwiĊciü przy doborze przewodów sygnaáowych, które mają byü stosowane z urządzeniami ze znakiem CE.
JakoĞü przewodu sygnaáowego, dáawic oraz záączy przewodu:
Firma Brooks Instrument dostarcza wysokiej jakoĞci przewody, które speániają wymagania zawarte w specyfikacji dla certyfikatu CE.
JeĪeli stosuje siĊ wáasne przewody sygnaáowe, to powinny one byü w caáoĞci w peáni ekranowane.
Záącza typu „D” lub okrągáe powinny zawieraü metalowy ekran. JeĞli to moĪliwe, naleĪy stosowaü metalowe dáawice przewodu zapewniające
mocowanie jego ekranu.
Ekran przewodu powinien byü poáączony z metalową osáoną lub dáawicą zapewniając caákowite, dookólne ekranowanie na obu koĔcach przewodu.
Ekran przewodu powinien byü uziemiony.
Záącza krawĊdziowe są standardowo niemetaliczne. Stosowane przewody muszą byü w peáni ekranowane zgodnie z certyfikatem CE.
Ekran przewodu powinien byü uziemiony.
Konfiguracja styków jest podana w niniejszej instrukcji obsáugi.
Wyáadowania elektrostatyczne (ESD)
UWAGA: Urządzenie zawiera czĊĞci elektroniczne podatne na uszkodzenia spowodowane áadunkami elektrostatycznymi. Przy
obchodzeniu siĊ z wewnĊtrznymi podzespoáami i czĊĞciami elektronicznymi naleĪy przestrzegaü nastĊpujących zasad
postĊpowania:
1. NaleĪy odáączyü zasilanie od urządzenia.
2. Osoba wykonująca czynnoĞci musi zostaü uziemiona za pomocą opaski na przegubie dáoni lub w inny, bezpieczny sposób, zanim przystąpi do
instalacji, wyjĊcia lub regulacji obwodów drukowanych lub innych wewnĊtrznych podzespoáów elektronicznych urządzenia.
3. Obwody drukowane naleĪy transportowaü w przewodzącym pojemniku. Páytki drukowane naleĪy wyjmowaü z opakowania ochronnego
bezpoĞrednio przed ich montaĪem. Wymontowane páytki naleĪy niezwáocznie umieĞciü w opakowaniu ochronnym sáuĪącym do transportowania,
skáadowania lub odsyáania do producenta.
Uwagi:
Fakt, Īe urządzenie zawiera czĊĞ
ci nieodporne na wyáadowania elektrostatyczne (ESD) jest rzeczą normalną. WiĊkszoĞü nowoczesnych urządzeĔ
elektronicznych zawiera komponenty wykonane w technologii tlenków metali (NMOS, SMOS itp.). Jak pokazuje praktyka, nawet niewielkie
wyáadowanie elektrostatyczne moĪe uszkodziü lub zniszczyü takie urządzenie. Uszkodzone czĊĞci, nawet jeĪeli na pozór dziaáają poprawnie, szybko
doprowadzają do nieprawidáowej pracy urządzenia.
Polish
A-15
Section A - Essential Instructions
Installation and Operation Manual
X-VA-FC-eng
Part Number: 541B045AAG
December, 2015
Flow Controllers for Gas and Liquid Service
Instruções Básicas
Ler antes de proceder!
A Brooks Instrument projecta, fabrica e testa os seus produtos de forma a satisfazer numerosas normas nacionais e internacionais. Estes
equipamentos devem ser instalados, utilizados e mantidos de forma adequada, e devem funcionar dentro da sua gama de utilização. As instruções
seguintes devem ser, durante a instalação, uso e/ou manutenção dos equipamentos da Brooks Instrument, apreendidas e integradas no plano de
protecção e segurança no trabalho.
x Para assegurar o desempenho adequado, a instalação, exploração, actualização e/ou manutenção do equipamento deve ser realizada,
exclusivamente, por pessoal qualificado.
x Antes de instalar, utilizar e/ou executar operações de manutenção devem ser lidas todas as instruções do equipamento. No caso do presente
manual não ser apropriado procure, na capa traseira, o distribuidor mais próximo e contacte-o para obter informações adicionais. Guarde este
manual para futura referência.
ATENÇÃO: não sujeite o equipamento a condições fora das gamas de serviços indicadas. Ao não respeitar esta advertência poderá
provocar avarias no equipamento e/ou danos pessoais.
x Se as instruções deste manual não estiverem suficientemente claras, contacte o representante Brooks Instrument para esclarecer as suas
dúvidas.
x Tenha sempre presente todas as advertências, apelos e instruções indicadas no equipamento e/ou fornecidas junto com o mesmo.
x A instalação do equipamento deverá ser efectuada cumprindo todas as instruções indicadas no manual assim como as normas e regulamentos
locais e nacionais vigentes. Ligue o equipamento exclusivamente a fontes de energia eléctrica e/ou pneumática adequadas.
x Procedimento: (1) Pressurize lentamente o sistema. Abra lentamente as válvulas para evitar variações bruscas de caudal. (2) Verifique se
fugas nas ligações de entrada e saída do medidor de caudal. Se não detectar fugas, poderá colocar o sistema à pressão de trabalho.
x Antes de efectuar qualquer operação de manutenção verifique sempre a possibilidade do equipamento estar sob pressão. No caso de ser
preciso substituir peças, estas devem ser as recomendadas pela Brooks Instrument e o trabalho de substituição deverá ser efectuado por
técnicos qualificados. Procedimentos e peças não conformes poderão alterar o desempenho do equipamento, danificá-lo ou colocar em risco a
sua segurança ou de outros. Substituir peças por outras não originais, meramente semelhantes, poderá originar choques eléctricos, fogo ou em
funcionamento inadequado.
x Deverá manter o equipamento intacto e fechado, verificando se as coberturas de protecção estão nos seus lugares devidos, de forma a evitar
choques eléctricos e/ou danos pessoais, excepto no caso de se tratar de um técnico qualificado e se estiver a executar trabalhos de
manutenção.
ATENÇÃO: Se por qualquer razão for necessário fechar as válvulas a montante e jusante do equipamento, tenha em atenção que o
mesmo deverá ser previamente esvaziado do fluído que o atravessa. Esta obrigação surge do facto de existir a possibilidade de ocorrer
dilatação térmica do líquido, no interior do aparelho, podendo provocar danos pessoais ou materiais graves.
Directiva Europeia para equipamentos sob pressão (PED)
Todos os equipamentos sujeitos a pressão interior superior a 0,5 bar (g) e com calibre superior a 25 mm (1 polegada) estão sob a vigência da
directiva europeia de equipamentos sob pressão (PED).
x O capítulo "Dados técnicos" do manual contém instruções relativas à Directiva PED.
x O caudalímetro objecto deste manual satisfaz a directiva 97/23/CE da UE.
x Os caudalímetros Brooks pertencem ao grupo 1 de fluidos.
x Os caudalímetros com calibre superior a 25 mm (1 polegada) pertencem às categorias PED I, II, ou III.
x
Os caudalímetros de 25 mm (1 polegada) ou menores seguem as “Boas regras de engenharia” (SEP).
Directiva Europeia sobre Compatibilidade electromagnética (EMC)
Os equipamentos (eléctricos/electrónicos) da Brooks Instrument que têm a marcação CE passaram os testes comprovativos dos requisitos de
compatibilidade electromagnética (Directiva EMC número 2004/108/EC).
Todavia, ao utilizar os aparelhos compete-lhe a escolha dos cabos de sinal adequados para os equipamentos com marcação CE.
Qualidade dos cabos de sinal, bucins e conectores:
A Brooks Instrument fornece cabos de alta qualidade que cumprem todos os requisitos da marcação CE.
No caso de utilizar os seus próprios cabos de sinal, assegure uma blindagem a 100%.
Os conectores do tipo “D” ou "circular" têm que ser blindados por uma malha metálica. Se precisar de usar bucins, estes têm que permitir a
crimpagem da malha/blindagem do cabo.
A blindagem do cabo deve ser ligada ao corpo metálico ou bocal e assegurando a blindagem em 360°. A blindagem deve terminar numa ligação à
terra.
Os conectores ligados a cartões serão, em geral, não-metálicos. Os cabos utilizados devem ter fita de blindagem a 100% para satisfazer a marcação
CE.
A blindagem, deverá terminar numa ligação à terra.
Atribuição de pinos: Veja as instruções de operação anexas.
Descarga Electrostática (ESD)
ATENÇÃO: Alguns componentes deste equipamento são susceptíveis à acção da electricidade estática, podendo ficar danificados. Ao
remover, colocar ou manipular placas de circuitos electrónicos deverá ter em atenção os seguintes procedimentos:
1. Desligar o equipamento da rede.
2. O utilizador, antes de qualquer intervenção que envolva os cartões de circuitos ou outros dispositivos internos, terá que se ligar à terra por meio
duma bracelete de pulso ou outro dispositivo adequado.
3. Os circuitos impressos deverão ser transportados numa embalagem condutiva. Os cartões só deverão ser retirados da embalagem protectora
imediatamente antes da sua inserção. O cartão retirado deverá ser recolocado imediatamente na embalagem protectora que servirá para o seu
transporte, armazenagem ou retorno a fábrica.
Observações:
Tenha presente que este equipamento poderá não ser o único objecto capaz de ser portador de peças sensíveis a descargas electrostáticas (ESD).
Na maioria dos dispositivos electrónicos Brooks encontram-se peças de tecnologia de óxidos metálicos (NMOS, SMOS, etc.). A experiência mostra
que até pequenas quantidades de electricidade estática são capazes de danificar ou destruir esses dispositivos. Os componentes danificados,
embora inicialmente funcionem aparentemente bem, acabam por ter falhas prematuramente.
Portuguese
Installation and Operation Manual
X-VA-FC-eng
Part Number: 541B045AAG
December, 2015
A-16
Section A - Essential Instructions
Flow Controllers for Gas and Liquid Service
IndicaĠii de referinĠă
CitiĠi-le întâi pe acestea!
Brooks Instrument îúi proiectează, produce úi testează produsele într-un mod ce respectă un mare număr de standarde autohtone úi internaĠionale.
Aceste instalaĠii trebuie amplasate, exploatate úi întreĠinute corespunzător, pentru ca în toate situaĠiile, domeniul lor de lucru să corespundă operării
normale. În ceea ce priveúte instalarea, operarea úi întreĠinerea produselor Brooks Instrument, indicaĠiile de mai jos trebuie respectate úi trebuie
introduse in programul de protecĠia muncii.
x Pentru garantarea prestaĠiei corecte, instalarea, operarea, actualizarea, programarea úi întreĠinerea produsului poate fi realizată doar de către
personal calificat.
x InstrucĠiunile de instalare ale produsului trebuie citite integral, înainte de punerea în serviciu úi exploatarea sa. În măsura în care ediĠia acestui
manual nu este cea adecvată, identificaĠi pe ultima copertă coordonatele distribuitorului local úi pentru lămuriri suplimentare adresaĠi-vă acestuia.
PăstraĠi acest manual pentru referinĠe ulterioare.
ATENğIE: Nu utilizaĠi instalaĠia în afara intervalului de funcĠionare indicat în instrucĠiunile de operare. Nerespectarea acestui lucru se
poate solda cu răniri grave de persoane sau defectarea instalaĠiei.
x În măsura în care indicaĠiile cărĠii maúinii nu sunt suficient de lămuritoare, luaĠi legătura cu reprezentantul Brooks Instrument pentru clarificarea
problemei.
x PăstraĠi toate avertismentele, avizele úi instrucĠiunile livrate odată cu instalaĠia sau inscripĠionate pe aceasta.
x EfectuaĠi instalarea echipamentului în conformitate cu indicaĠiile de instalare corespunzătoare, respectiv cu respectarea prevederilor naĠionale.
Echipamentul se conectează exclusiv la surse de energie electrică úi de presiune corespunzătoare.
x Succesiune: (1) PresurizaĠi lent instalaĠia. DeschideĠi încetul cu încetul supapa de funcĠionare pentru evitarea fluctuaĠiilor de flux. (2) ControlaĠi
dacă nu sunt prelingeri la intrarea sau ieúirea debitmetrului de branúare. Dacă nu sunt scurgeri, presurizaĠi instalaĠia la presiunea de lucru.
x Înaintea exploat
ării/ întreĠinerii, verificaĠi neapărat dacă conducta uzinală nu este sub presiune. În măsura în care este nevoie de piese de
schimb, este neapărat necesar ca manevrarea pieselor de schimb să fie făcută de personal cu calificare profesională agreat de Brooks
Instrument. Utilizarea altor piese de schimb decât cele originale úi licenĠiate poate avea efecte asupra performanĠelor instalaĠiei úi asupra
siguranĠei sale în exploatare. Utilizarea de piese asemănătoare de substituire poate avea ca rezultat pericol de incendiu úi electrocutare.
x În toate cazurile toate uúile instalaĠiei trebuie să fie închise, cuútile de protecĠie să fie puse la locurile lor, pentru evitarea electrocutării úi rănirii de
persoane, exceptând situaĠiile când un specialist efectuează lucrări de întreĠinere.
ATENğIE: În cazul instalaĠiilor cu flux de fluide, dacă din orice motiv este necesară închiderea valvelor de intrare úi ieúire, limitrofe
instalaĠiei, instalaĠia trebuie complet golită. Neglijarea acestui lucru poate avea ca efect dilatarea termică a fluidului, care poate defecta
instalaĠia úi poate produce răniri de persoane.
Directiva europeană pentru instalaĠiile sub presiune (PED)
Toate instalaĠiile úi sistemele presurizate ce se află sub presiuni interne ce depăúesc 0,5 mbar (g) úi au mai mult de 25 mm sau 1 Ġol, cad sub
incidenĠa normei europene corespunzătoare (PED).
x La capitolul "Date tehnice" din cartea maúinii se găsesc indicaĠiile corespunzătoare directivei PED.
x Mijloacele de măsurare menĠionate în cartea maúinii corespund directivei 97/23/EK EU.
x Toate debitmetrele Brooks corespund clasei 1 de fluide.
x Mijloacele de măsurare mai mari de 25 mm sau 1 Ġol corespund categoriei PED I, II sau III.
x Mijloacele de măsurare mai mici de 25 mm sau 1 Ġol se conformează practicii inginereúti acceptate (SEP).
Directiva europeană privitoare la compatibilitatea electromagnetică (EMC).
InstalaĠiile (electrice /electronice) ce poartă marca Brooks Instrument CE îndeplinesc cu succes cerinĠele testelor de verificare ale compatibilităĠii
electromagnetice (Cf. directivelor europene EMC cu nr. 2004/108/EC).
În acelaúi timp trebuie acordată o atenĠie deosebită la alegerea cablurilor de semnalizare utilizate pentru instalaĠiile ce poartă marcajul CE.
Calitatea cablurilor de semnalizare, a legăturilor prin cablu úi a conectoarelor:
Brooks Instrument oferă cabluri de calitate ridicată, care corespund cerinĠelor calitative ale CE.
În măsura în care folosiĠi cabluri proprii, trebuie alese acelea care sunt 100% ecranate úi prevăzute cu filtre
.
Conectoarele „D” sau cele „circulare” trebuie sa dispună de ecrane metalice. În caz de nevoie trebuie folosite conectoare metalice pentru montarea
filtrelor de cablu.
Filtrul de cablu trebuie conectat la carcasa metalică sau manúon úi în ambele cazuri trebuie asigurată ecranarea la 360°. Ecranarea trebuie terminată
cu o legare la pământ.
Conform standardului, conectoarele aparĠinând plăcilor electronice nu sunt metalice. Cablurile folosite trebuie să fie 100% ecranate úi prevăzute cu
filtre pentru a corespunde clasificării CE.
Ecranarea trebuie terminată cu o legare la pănt.
ConfiguraĠie de contact: Vezi instrucĠiunile de operare ataúate.
Descărcare electrostatică (ESD)
ATENğIE: InstalaĠia include piese care sunt predispuse la defectare sub influenĠa electricităĠii statice. Trebuie respectate metodele
corespunzătoare de extragere, instalare sau alte manipulări ale circuitelor electronice.
Procedură de manipulare:
1. InstalaĠia trebuie scoasă de sub tensiune.
2. Înaintea de inserarea, scoaterea sau reglarea vreunei cartele electronice, sau a altui dispozitiv intern, persoana trebuie să se lege la pământ cu
banda pentru articulaĠia mâinii sau alte dispozitive de siguranĠă disponibile pentru acest scop.
3. Cartelele cu cablaje electronice imprimate trebuie transportate în ambalaje anti-electrostatice (conductoare). Cartelele se pot scoate din ambalaj,
doar nemijlocit înaintea amplasării lor. Cartela demontată trebuie pusă neîntârziat în ambalajul de protecĠie în vederea transportării, a depozitării
sau returnării la producător.
ObservaĠii:
În echipamente se găsesc adesea componente sensibile la descărcare electrostatică (ESD). Majoritatea echipamentelor moderne includ componente
electronice realizate în tehnologie metal-oxid semiconductor (NMOS, SMOS, etc.) ExperienĠa a dovedit că acestea pot fi afectate sau deteriorate chiar
de energii electrostatice de slabă intensitate. Componentele defectate, cu toate că în aparenĠă sunt funcĠionale, duc în timp la defecĠiuni incipiente.
Romanian
A-17
Section A - Essential Instructions
Installation and Operation Manual
X-VA-FC-eng
Part Number: 541B045AAG
December, 2015
Flow Controllers for Gas and Liquid Service
Základné príkazy
PreþítaĢ pred inštaláciou!
Brooks Instrument svoje výrobky projektuje, vyrába a testuje takým spôsobom, aby tieto vyhoveli domácim aj medzinárodným normám. Tieto
zariadenia je potrebné predpísaným spôsobom inštalovaĢ, prevádzkovaĢ a udržiavaĢ, na zabezpeþenie ich spoĐahlivej a normálnej prevádzky v celom
pracovnom rozsahu. Nižšie uvedené príkazy je potrebné dodržiavaĢ a zaþleniĢ do programu bezpeþnostných predpisov v priebehu inštalácie,
prevádzky a údržby výrobkov Brooks Instruments.
V záujme zabezpeþenia vyhovujúceho výkonu inštaláciu, prevádzku, programovanie, aktualizáciu a údržbu zariadení má vykonávaĢ výluþne
odborne kvalifikovaný personál.
Pred inštaláciou, prevádzkou a servisu zariadení je potrebné preþítaĢ všetky príkazy. Ak táto príruþka nie je správna, tak na zadnej strane treba
nájsĢ miestneho distribútora, kontaktovaĢ ho pre ćalšie informácie. Pre neskoršie informácie uschovajte príruþku.
UPOZORNENIE: NeprevádzkovaĢ zariadenie v rozsahu mimo rozsahu uvedenom v prevádzkovej príruþke. Porušenie tohto oznámenia
môže maĢ za následok Ģažkú ujmu na zdraví a vedie k poškodeniu zariadenia.
x Ak príkazy v návode nie sú jednoznaþné, kontaktujte zástupcu Brooks Instrument na objasnenie problémov.
x Dodržujte všetky upozornenia, príkazy a usmernenia uvedené na zariadení, alebo s ním dodané.
x Zariadenia inštalujte podĐa návodu uvedeného v príkaze na inštaláciu, v súlade s miestnymi a národnými predpismi. Zariadenie pripojte výluþne
len na vyhovujúci elektrický a tlakový zdroj
x Postup: (1) Pomaly natlakujte systém. Prevádzkový ventil otvorte pomaly na zamedzenie kolísania prietoku. (2) Prekontrolujte tesnosĢ vstupného
a výstupného zapojenia prietokomeru. Keć nie je presakovanie, spoje sú tesné, naplniĢ systém na prevádzkový tlak.
x Pred vykonávaním servisných prác kontrolovaĢ, þi systém nie je pod tlakom. V prípade, že je potrebná výmena súþiastky, výmenu dielov,
urþených Brooks Instrument musí vykonaĢ kvalifikovaná osoba. Použitie nepovolených dielov a vykonávanie nepovolených aktivít ohrozujú
bezpeþnosĢ prevádzvky a majú negatívny vplyv na výkon zariadenia. Nahradenie súþiastok len podobnými komponentmi môže maĢ za následok
požiar, úraz elektrickým prúdom alebo nedostatoþnú funkciu zariadenia
x Všetky ochranné kryty, dvierka zariadenia majú byĢ zatvorené na zabezpeþenie ochrany proti úrazu elektrickým prúdom a proti poraneniam
obsluhy. Výnimku tvorí vykonávanie údržby kvalifikovaným odborníkom.
UPOZORNENIE: Pri zariadeniach s prietokom kvapalín, keć z akéhokoĐvek dôvodu je nutné uzavrieĢ vstupné a výstupné ventily,
zariadenie je potrebné úplne vyprázdniĢ. Zanedbanie vypúšĢania má za následok poškodenie zariadenia s možnosĢou zranenia obsluhy z
dôvodu tepelnej rozĢažnosti náplne.
Európska smernica vzĢahujúca sa na tlakové zariadenia (PED)
x Všetky zariadenia s vyšším vnútorným pretlakom ako 0,5 bar (g), a väþšieho rozmeru ako 25 mm alebo 1 anglický palec, podliehajú pod
Európsku smernicu vzĢahujúcu sa na tlakové nádoby (PED).
x Kapitola "Technické údaje" návodu na obsluhu obsahuje príkazy vzĢahujúce sa na smernicu PED.
x Meracie prostriedky uvedené v návode na obsluhu vyhovujú smernici 97/23/ES EÚ.
x Všetky prietokomery Brooks patria do 1. skupiny kvapalín.
x Meracie prístroje presahujúce rozmery 25 mm alebo 1 " spĎĖajú I., II., alebo III. kategóriu PED.
x Meracie prístroje menšie alebo rovné ako 25 mm alebo 1 " zodpovedajú zaužívanej meracej praxi (SEP).
Európska smernica vzĢahujúca sa na elektromagnetickú kompatibilitu (EMC)
Elektrické / elektronické zariadenia Brooks Instrument, ktoré si zaslúžili znaþku CE, úspešne splnili skúšobné testy požiadaviek elektromagnetickej
kompatibility (smernica EMC þ. 2004/108/EC).
Pritom treba venovaĢ zvláštnu starostlivosĢ na výber signálnych káblov zariadenia, s oznaþením CE.
Kvalita signálnych káblov, káblových spojov a prípojov:
Brooks Instrument ponúka vysoko kvalitné káble, ktoré spĎĖajú požiadavky kvalitatívneho zaradenia CE.
Ak použijete vlastné signálne káble, majú maĢ 100%-né tienenie, s plným filtrovaním.
Prípojky "kruhové" alebo tvaru "D" majú maĢ kovové tienenie. V prípade potreby treba použiĢ kovové káblové spojky k upevneniu káblového filtra.
Káblový filter treba pripojiĢ ku kovovému telesu alebo k puzdru, na oboch stranách zabezpeþiĢ tienenie v kruhu 360 °. Tienenie má byĢ ukonþené
uzemnením.
Prípojky vedúce ku kartám podĐa noriem sú nekovové. Použité káble, pre vyhovenie predpisom CE musia maĢ 100%-né filtrovanie tienením.
Tienenie má byĢ ukonþené uzemnením.
Konfigurácia kontaktov: Vić priložený návod na obsluhu. .
Elektrostatický výboj (ESD)
UPOZORNENIE: Prístroj obsahuje súþiastky, ktoré môžu byĢ poškodené od elektrostatických nábojov. Pri montáži, odstraĖovaní alebo
inej údržby vnútorných obvodových kariet je potrebné dodržiavaĢ príslušné postupy.
Postup ošetrovania:
1. Zariadenie odpojiĢ od napájania.
2. Osoba vykonávajúca údržbu má byĢ uzemnená uzemĖujúcim náramkom, alebo iným, na túto prácu vyhovujúcim spôsobom pred vykonávaním
inštalácie, demontáže a nastavenia obvodových kariet alebo iného vnútorného prostriedku.
3. Karty obvodov sa musia prepravovaĢ v elektricky vodivom balení. Karty sa môžu vyberaĢ z ochranného obalu výluþne len tesne pred montážou,
zasunutím! Vybranú kartu okamžite treba umiestniĢ do ochranného obalu, urþeného pre dopravu, skladovanie, alebo pre spätnú prepravu do
výrobného závodu.
Poznámky:
Existencia prvkov, ktoré sú citlivé na elektrostatické výboje (ESD) v prístroji je þastým javom. U väþšiny moderných elektronických prostriedkov sú
použité prvky s technológiou oxidu kovov (NMOS, SMOS, atć.). Skúsenosti dokazujú, že aj nepatrné elektrostatické výboje poškodzujú, zniþia tieto
prostriedky. Poškodené súþiastky, aj keć zdanlivo pracujú bez chyby, odkazujú na vznikajúce poruchy.
Slovak
Installation and Operation Manual
X-VA-FC-eng
Part Number: 541B045AAG
December, 2015
A-18
Section A - Essential Instructions
Flow Controllers for Gas and Liquid Service
Osnovna navodila
Najprej preberite jih
Brooks Instrument tako konstruira, izdeluje in terstira svoje izdelke, da oni ustrezajo številnim domaþim in mednarodnim standardom. Te naprave se
morajo ustrezno instalirati, koristiti in vzdrževati, da vsekakor delajo ustrezno normalnom podroþju funkcioniranja. Naslednjih navodil se mora držati in
potrebno je vgraditi v program varstva pri delu pri instaliranju, korišþenju in vzdržavanju izdelkov proizvajalca Brooks Instrument.
x Za jemstvo ustreznega uþinka naj izkljuþno strokovno osobje opravlja instaliranje, korišþenje, osveženje, programiranje in vzdrževanje izdelka.
x Potrebno je prebrati vsa navodila pred instaliranjem, korišþenjem in servisiranjem izdelka. V kolikor ta priroþnik ni ustrezna publikacija, na zadnji
strani poišþite lokalnega distributerja in za nadaljnje informacije stopite z njim v kontakt. Prihranite ta priroþnik za poznejše informacije.
OPOMBA: Ne koristite napravo izven podroþja iz navodila za uporabo. Prekršek tega lahko privede do osebnih poškodb ali okvare
naprave.
x V kolikor navodila priroþnika niso enosmiselna, stopite v kontakt z zastopnikom društva Brooks Instrument, da razþistite problem.
x Držite se vseh opozoril, povabil, navodil, ki so navedena na napravi ali skupaj z njim izporoþena.
x Napravo instalirajte shodno navodilom in relevantnim lokalnim in nacionalnim navodilom iz navodila za instalirenje.. Izdelek spojite izkljuþno na
ustrezni izvir elektrike in obskrbo tlaka.
x Proces: (1) Poþasi položite sistem pod tlak. Poþasi odpirajte pogonske ventile zaradi izogibanja nihanju pretoka. (2) Preverjajte, ima li curljanja pri
povezu vstopa in izstopa merilca toka. ýe ni curljanja, naplonite sistem na pogonski tlak.
x Pred servisom vsekakor preverjajte, ali je pogonski vod pod tlakom. ýe je potreben rezervni del, svekakor strokovna oseba mora rokovati z
rezervnimi deli odrejenimi od Brooks Instrument. Nedovoljeni rezervni deli in dejavnosti lahko vplivajo na uþinek izdelka, oziroma ugrožavajo
varnostni pogon. Sprememba samo z podobnimi rezervnimi deli lahko ima za posledico požar, nevarnost elektiþnega šoka ali nedovoljno
funkcioniranje.
x Vsa vrata naprave svekakor morajo biti zaprta, zašþitni ovitki morajo biti na svojem mestu zaradi izogibanja šoku in osebnim poškodbam, razen,
þe na njej strokovnjak opravlja dela vzdrževanja.
OPOMBA: V primeru naprave za tok tekoþine, þe je iz katera koli razloga potrebno zapreti vstopne in izstopne ventile pri napravi,
naprava se mora celotno izprazniti. Zamuda tega lahko provzroþi toplotno proširjenje tekoþine, kar poškoduje napravo in lahko povrzoþi
osebno poškodbo.
Europske smernice za naprave ohranjanja pritiska (PED)
Vsaka naprava ohranjanja pritiska z notranjim pritiskom veþ od 0,5 bara (g) in veþjim od 25 mm ali 1 palca sodi pod Europskim smernicam za
ohranjanje pritiska (PED).
x Poglavje priroþnika „Tehniþni podatki” vsebuje navodila, ki se nanašajo na smernice PED.
x Merilni instrumenti navajani v priroþniku ustrezajo smernicam EU številke 97/23/EK
x Vsaki merilec pretoka Brooks sodi v skupino tekoþin številke 1.
x Merilni instrumenti veþji od 25 mm ali 1 palca ustrezajo kategriji PED I, II, ali III.
x Merilni instrumenti manjši od 25 mm oziroma 1 palca ali manjši sledijo sprejeti inženjeski praksi (SEP).
Evropska smernica za Elektromagnetno kompatibilnost (EMC)
Naprave Brooks Instrument, ki so zaslužile CE oznaþbo (elektriþni/elektronski) so uspešno izpolnile testove zahteve o elektromangnetni
kompatibilnosti (št. 2004/108/EC smernice EMC) .
Obenem mora se posebno pozornost posvetiti na izbiro signalnega kabla, ki se uporabljajo za naprave z oznaþbo CE.
Kakaovost signalnih kablov, povezav kablov, prikljuþkov:
Brooks Insturment nuja kabele visoke kakovosti, ki ustrezajo zahtevam kvalificiranja CE.
V kolikor se uporbalja lastni signalni kabel, treba je izbrati, ki za 100 % senco v polni meri filtriran.
Prikljuþki „D” „olika kroga” morajo biti zasenþeni kovonskom sencom. ýe bo potrebno, uporabite kovinske povezave za pritrditev filtra kabla
Filtar kabla je treba prikljuþiti na kovinsko ohišje ali plašt in na obe polovici je treba senþiti v 360°. Senþenje mora završiti v ozemljitvi.
Prikljuþki, ki sodijo karitcam normalno nisu kovinskik. Korišþeni kabli moraju biti filtrirani s 100 % senco, da odgovarjajo CE kvalifikaciji.
Sencanje mora imat konec v ozemljitvi.
Konfiguracija stika: Vidi priloženo navodilo za uporabo.
Elektrostatiþno izpražnjenje (ESD)
OPOZORILO: Naprava vsebuje take sestavne dele, ki so naklonjeni k poškodbi od statiþne elektrike. Treba se je držati ustreznih
postopkov pri odstranjevanju, vlogu ali drugega rokovanja kartic in sredstev notranjih tokovnih krogov.
Posotpek rokovanja:
1. napravo je treba izklopiti iz elektriþnega toka.
2. Osebo je treba ozemljiti zapestnim pašþekom ali z drugim varnostnim in za ta namen primernim sredstvom preden bi instalirala, jemala, ali
nastavila kartico za tokovni krog ali drugo notranjo opremo.
3. Tiskane kartice tokovnega kroga je treba izporoþiti v konduktivni embalaži. Karte so odstranjive izkljuþno neposredno pred vlogom iz zašþitne
embalaže ven. Izjemljeno kartico nemudoma staviti v zašþitno embalažo za gibanje, skladišþenje ali pošiljanje nazaj.
Opombe:
Nije poseben pojav, da se v napravi nahajajo obþutljivi sestavni deli na elektrostatiþno pražnjenje (ESD). V veüem delu modernih elektronskih
sredstev nahajajo se sestavni deli na kovinsko oksidno tehnologijo (NMOS, SMOS itd..). Izkustva potrjujejo, da majhna statiþna elektrika more
poškodovati ali uniþiti ta sredstva. Oškodovani rezervni deli, þe na videz dobro delajo, nakažejo zaþetno napako.
Slovene
A-19
Section A - Essential Instructions
Installation and Operation Manual
X-VA-FC-eng
Part Number: 541B045AAG
December, 2015
Flow Controllers for Gas and Liquid Service
Instrucciones básicas
¡Léalos primero!
El Brooks Instrument proyecta, fabrica y prueba sus productos de manera que éstos respondan a numerosas normas nacionales e internacionales. Dichas
instalaciones deben ser emplazadas, operadas y mantenidas adecuadamente, para que puedan marchar de todas formas en conformidad con el alcance
normal de funcionamiento. Las siguientes instrucciones deben cumplirse y incorporadas en su programa de seguridad cuando instalando, operando y
mantenimiento los productos Brooks Instrument.
x Para asegurar el adecuado rendimiento, para instalar, operar, actualizar, programar y mantener tiene que realizarse exclusivamente por una persona
calificada.
x Antes de la instalación, operación y servicio del producto leer todas las respectivas instrucciones. Si el presente manual no es la adecuada publicación,
busque al distribuidor local que figura en la contraportada y póngase en contacto con él para obtener informaciones. Guarde el presente manual para
tener informaciones también en el futuro.
ATENCIÓN: No haga funcionar los equipos fuera del rango indicado en las instrucciones de funcionamiento. El incumplimiento de estas últimas
puede conducir a graves daños personales o a la avería del equipo.
x Si las instrucciones del manual no son evidentes, póngase en contacto con el representante de Brooks Instrument para aclarar el problema
x Observar todas las alertas, advertencias e instrucciones indicadas en el equipo o suministradas con el mismo.
x Instale su equipo en conformidad con las recomendaciones indicadas en las respectivas instrucciones de instalación y con las pautas de las normas
vigentes locales e internacionales. Conectar el producto exclusivamente a la adecuada fuente eléctrica y presión.
x Proceso: (1) Colocar lentamente flujo en el sistema. Abrir lentamente las válvulas de proceso para evitar oscilación del flujo. (2) Verificar si hay fuga
alrededor de las conexiones de entrada y salida del flujómetro, Si no hay, llenar el sistema con la presión de operación.
x Antes de efectuar el servicio, verificar si hay presión o no en la tubería de la red. Si se requiere realizar un recambio de piezas, solamente el personal
calificado puede manipular las piezas de repuesto determinadas por Brooks Instrument Las piezas y operaciones no autorizadas pueden afectar el
rendimiento del producto o arriesgar el funcionamiento seguro. El recambio realizado con piezas sólo similares pueden traer como consecuencias
incendios, choques eléctricos o funcionamiento bajo.
x Todas las puertas de la instalación deben estar cerradas, las cubiertas de protección tienen que hallarse en el debido sitio con el fin de evitar los daños
personales y los choques eléctricos, salvo cuando un especialista efectúa el mantenimiento.
ADVERTENCIA: En caso de instalaciones que circulen líquido, si por cualquier razón se hubiera de cerrar las válvulas de entrada y salida
situadas al lado del equipo, dichas instalaciones deberán ser completamente vaciadas. La omisión de esto último puede provocar la dilatación
térmica del líquido, lo que puede dañar al equipo y conducir a daños personales.
Directriz Europea de los Equipos de Presión (PED)
Todos los equipos de presión, con una presión interna que supere a 0,5 bar (g) con tamaño mayor a 25 mm o 1 pulgada entran el ámbito de la Directriz
Europea de los Equipos de Presión (PED).
x El capítulo Datos Técnicos del manual incluye las instrucciones respecto a las directivas de PED
x Los instrumentos de medición indicados en el Manual responden a las EN directivas 97/23/EC.
x Todos los flujómetros Brooks pertenecen a la categoría 1 del grupo de fluidos.
x Los instrumentos de medición más grandes que 25 mm o 1 pulgada están en conformidad con las categorías I, II o III de PED
x Los instrumentos de medición más pequeños que 25 mm o 1 pulgada siguen la Práctica Aceptada de Ingeniería (SEP).
Directriz Europea respecto a la Compatibilidad Electromagnética (EMC)
Las instalaciones de Brooks Instrument (eléctricas/electrónicas) merecedores de la categoría CE cumplieron con éxito las pruebas que verifican las exigencias
de la compatibilidad electromagnética (directiva de EMC 2004/108/EC).
Al mismo tiempo se ha de prestar una especial atención en la selección de los cables de señal, utilizados con los equipos marcados con CE.
Calidad de los cables de señal, piezas de unión de cable y conectores:
El Brooks Instrument ofrece cables de alta calidad, que responden a los requerimientos de calificación CE.
Si se utiliza cable propio de la firma, se ha de elegir uno que sea completamente filtrado con blindaje de 100%.
Las piezas de unión de forma „D” o „circular” deben ser blindadas mediante blindaje metálica. Si es necesario, aplicar piezas de unión de metal para sujetar el
filtro de cable.
Conectar el filtro de cable a la caja o manguito de metal blindándolo en ambas caras en 360°.
El blindaje debe terminar en tierra.
Los conectores que pertenecen a las tarjetas normalmente no son metalizados. Los cables utilizados deben ser filtrados con una blindaje de 100% para
responder a la calificación CE.
El blindaje debe terminarse en tierra.
Configuración de contacto: Véase Instrucciones de operación adjuntas.
Descarga Electroestática (ESD)
PRECAUCIÓN: El aparato incluye piezas electrónicas que son susceptibles a los daños provocados por la electricidad estática. Observar los
adecuados procesos para remover, instalar o manipular las tareas y medios de circuitos eléctricos internos
Proceso de operación:
1. Desconectar la fuente eléctrica de la unidad.
2. La persona debe ponerse a tierra mediante una palanca acodada o por otro medio seguro y apropiado para dicho fin antes de instalar, sacar o ajustar el
circuito impreso eléctrico u otro medio interno.
3. El circuito impreso debe ser transportado en embalaje conductivo. Las tarjetas no pueden sacarse de la cubierta protectora exclusivamente directamente
antes de la instalación. Las tarjetas desmontadas deben colocarse sin tardar en el embalaje protector utilizado para manipulación, almacenamiento o
devolución a la fábrica.
Notas:
Esto equipo no es el único contenido de piezas susceptibles a la descarga electroestática (ESD). En la mayoría de los medios electrónicos modernos se
encuentran piezas fabricadas por tecnología de óxido metálico. (NMOS, SMOS etc.). Las experiencias confirman que incluso una mínima electricidad estática
puede dañar o destruir dichos medios. Las piezas averiadas, aunque funcionen aparentemente bien, indican una falla inicial.
Spanish
Installation and Operation Manual
X-VA-FC-eng
Part Number: 541B045AAG
December, 2015
A-20
Section A - Essential Instructions
Flow Controllers for Gas and Liquid Service
Väsentliga anvisningar.
Läs detta innan du fortsätter !
Brooks Instrument konstruerar, tillverkar och testar sina produkter med syfte att uppfylla alla nationella och internationella standarder. Dessa produkter måste
installeras på rätt sätt, handhas och underhållas för att de skall fungera kontinuerligt enligt deras normala specifikation. De följande anvisningarna bör följas
och integreras till Ert säkerhetsprogram varje gång när Brooks Instruments produkter installeras, handhas och underhålls.
x För att garantera angiven funktion, använd kvalificerad personal till att installera, handha, uppgradera, programmera och serva produkten.
x Läs alla instruktioner innan produkten installeras, startas upp och underhålls. Om du finner att denna instruktionshandbok inte är den rätta
instruktionsboken, titta på i slutet av pärmen för information om hur man kan kontakta lokala representanter. Spara denna instruktions manual för senare
behov.
VARNING: Kör inte detta instrument utanför dess specifikationer som är angiven i Instruktionsboken. Undvikande att ta denna varning
kan leda till allvarliga personliga skador och / eller skada utrustningen.
x Om du inte förstår någon av dessa instruktioner, kontakta din representant för Brooks Instrument för klarläggande.
x Följ alla varningar och instruktioner som följer med leveransen av denna produkt.
x Installera din utrustning på sättet som anges i den gällande handbokens installationsanvisningar och enligt tillämpliga lokala och nationella föreskrifter.
Koppla varje produkt till föreskriven ström- och tryckkällan.
x Igångsättning: (1) Koppla långsamt på flöde i systemet. Öppna processventiler sakta för att undvika för höga flöden. (2) Kontrollera läckor vid mätarens
anslutningar för in- och utlopp. Om inget läckage förekommer, kör systemet upp till drifttrycket.
x Kontrollera att processledningens tryck är bortkopplat före service. I fall det behöves kompletteras med nya delar, se till att komponenter föreskrivna av
Brooks Instrument används. Samt att kvalificerad personal utför arbetet. Ej rekommenderade komponenter och åtgärder kan påverka produktens
prestanda och sätta din driftsäkerhet på spel. ”Felaktiga” ersättningar kan orsaka eld, elektriska skador samt felaktig funktion.
x Se till att anordningens kåpor och skyddslock ligger på sin plats med syfte att förebygga elektriska kontakt och personliga skador; det enda undantag
gäller när underhållsarbete utförs av kvalificerad personal.
VARNING: I fall av - flödesmätare / regulatorer för vätskor: Ifall ventiler före och efter skall stängas av, måste alla ledningar tömmas på all
vätska. Att ej tömma ledningar alt koppla bort trycket kan göra så att vätskans värmeutvidgning kan spräcka / skada utrustningen och orsaka
personliga skador.
European Pressure Equipment Directive (PED) - (Rådets Direktiv 99/36/EG av den 29 april 1999[1] om transportabla
tryckbärande anordningar)
Alla utrustning för tryck med ett tryck över 0.5 Bar(g) bar och större demensioner än 25 mm eller 1" (inch) faller under Tryck direktiv 99/36/EG av den 29 april
1999[1] om transportabla tryckbärande anordningar - PED.
x Den här Instruktionsbokens Sektion ” Specifikation” innehåller anvisningar gällande PED Direktivet.
x Mätare som beskrivs i denna Instruktionsbok är i överensstämmelse med EN Direktivet 97/23/EC.
x Brooks Instruments alla flödesmätare faller under flödesgrupp nr. I.
x Mätare som är större än 25 mm eller 1" (inch) överensstämmer med PED kategorier I, II eller III.
x Mätare på 25mm eller 1" (inch) eller mindre faller under Sound Engineering Practice (SEP) (God Teknisk Praxis).
European Electromagnetic Compatibility (EMC) - Elektromagnetisk kompatibilitet
Brooks Instrument (elektriska/elektroniska) CE-märkta anordningar har redan genomgått ett framgångsrikt prov enligt regleringar under Electromagnetic
Compatibility (EMC directive 2004/108/EC). Man måstre dock ägna särskild uppmärksamhet till valet av signalkabeln som skall används för CE-märkta
anordningar.
Signalkablars, packboxars och kontakdons kvalitet:
Brooks Instrument levererar högkvalitativa kablar som överensstämmer med specifikation för CE-intygade produkter.
Om man använder sin egen signalkabel, då bör man använda en kabel som är fullständigt skärmad med en 100% avskärmning.
“D” eller “Cirkelformiga” kontakdon skall vara skärmade med metalliska avskärmningar. Om det är användbart, bör metallpackboxar som ger en bra
fastspänning för kabelskärmar användas.
Kabelavsärmningen måste kopplas till den metalliska skärmande anordningen eller packboxen och skärmas vid båda ändar runt omkring. Avskärmningens
avspänning måste jordas.
Card Edge Kontaktdon är icke metalliska. För att överensstämma med krav på CE-intyg, skall de kablarna som används vara skärmade med 100%
skärmning.
Skärmningen måste jordas.
Vad gäller stiftkonfigurationen: Se den bifogade Instruktionshandboken.
ESD (Elektrostatiska urladdningar)
OBS: Denna utrustning innehåller elektroniska komponenter som är lättpåverkade av skada orsakad av statisk elektricitet. Lämplig
hanteringsprocedur måste följas när man tar bort, installerar eller på något annat sätt hanterar inre kretskort eller andra anordningar.
1. Ström till enheten måste kopplas från.
2. Personalen måste jordas med hjälp av ett armband eller något annat säkert medel innan något kretskort eller andra inre anordningar installerras, tas bort
eller justeras.
3. Kretskort måste transporteras i en speciell förpackning för elektronik. Kort skall ej tas bort från deras skydsskåpa innan man skall installera dem. De
borttagna korten bör omedelbart läggas i speciell förpackning för transport, lagring eller återlämnande till fabriken.
Anmärkningar:
Dessa instrument är ej unika vad gäller dess ESD (Elektrostatiska urladdningar) - känsliga komponenter. De flesta samtida konstruktioner innehåller
komponenter som utnyttjar metalloxid teknologi (NMOS, SMOS, o.s.v.). Erfarenhet har visat att även små mängder av statisk elektricitet kan skada eller
förstöra dess komponenter. Skadade komponenter - även om de annars verkar fungera ordentligt – har ofta en kortare livslängd. .
Swedish
Installation and Operation Manual
X-VA-FC-eng
Part Number: 541B045AAG
December, 2015
Flow Controllers for Gas and Liquid Service
THIS PAGE WAS
INTENTIONALLY
LEFT BLANK
Installation and Operation Manual
X-VA-FC-eng
Part Number: 541B045AAG
December, 2015
Flow Controllers for Gas and Liquid Service
TRADEMARKS
Brooks....................................................................... Brooks Instrument, LLC
Kalrez....................................................................... DuPont Dow Elastomers
NRS .......................................................................... Brooks Instrument, LLC
Teflon .............................................................E.I. DuPont de Nemours & Co.
Viton........................................................... DuPont Performance Elastomers
LIMITED WARRANTY
Seller warrants that the Goods manufactured by Seller will be free from defects in materials or workmanship under normal use
and service and that the Software will execute the programming instructions provided by Seller until the expiration of the
earlier of twelve (12) months from the date of initial installation or eighteen (18) months from the date of shipment by Seller.
Products purchased by Seller from a third party for resale to Buyer (“Resale Products”) shall carry only the warranty extended
by the original manufacturer.
All replacements or repairs necessitated by inadequate preventive maintenance, or by normal wear and usage, or by fault of
Buyer, or by unsuitable power sources or by attack or deterioration under unsuitable environmental conditions, or by abuse,
accident, alteration, misuse, improper installation, modification, repair, storage or handling, or any other cause not the fault of
Seller are not covered by this limited warranty, and shall be at Buyer’s expense.
Goods repaired and parts replaced during the warranty period shall be in warranty for the remainder of the original warranty
period or ninety (90) days, whichever is longer. This limited warranty is the only warranty made by Seller and can be
amended only in a writing signed by an authorized representative of Seller.
BROOKS SERVICE AND SUPPORT
Brooks is committed to assuring all of our customers receive the ideal flow solution for their application, along with
outstanding service and support to back it up. We operate first class repair facilities located around the world to provide
rapid response and support. Each location utilizes primary standard calibration equipment to ensure accuracy and reliability
for repairs and recalibration and is certified by our local Weights and Measures Authorities and traceable to the relevant
International Standards.
Visit www.BrooksInstrument.com to locate the service location nearest to you.
START-UP SERVICE AND IN-SITU CALIBRATION
Brooks Instrument can provide start-up service prior to operation when required.
For some process applications, where ISO-9001 Quality Certification is important, it is mandatory to verify and/or (re)calibrate
the products periodically. In many cases this service can be provided under in-situ conditions, and the results will be traceable
to the relevant international quality standards.
CUSTOMER SEMINARS AND TRAINING
Brooks Instrument can provide customer seminars and dedicated training to engineers, end users and maintenance persons.
Please contact your nearest sales representative for more details.
HELP DESK
In case you need technical assistance:
Americas
1 888 554 FLOW
Europe +31 (0) 318 549 290
Asia +81 (0) 3 5633 7100
Due to Brooks Instrument's commitment to continuous improvement of our products, all specifications are subject to change
without notice.

Documenttranscriptie

Installation and Operation Manual X-VA-FC-eng Part Number: 541B045AAG December, 2015 Flow Controllers for Gas and Liquid Service Brooks® Flow Controllers for Gas and Liquid Service Model FC 8744, Series FC 8800 and FC 8900 Series FC 8800 / FC 8900 Flow Controller Model 1350G with FC 8800 Flow Controller Model FC 8744 Flow Controller Flow Controllers for Gas and Liquid Service Installation and Operation Manual X-VA-FC-eng Part Number: 541B045AAG December, 2015 Installation and Operation Manual X-VA-FC-eng Part Number: 541B045AAG December, 2015 Flow Controllers for Gas and Liquid Service Dear Customer, We appreciate this opportunity to service your flow measurement and control requirements with a Brooks Instrument device. Every day, flow customers all over the world turn to Brooks Instrument for solutions to their gas and liquid low-flow applications. Brooks provides an array of flow measurement and control products for various industries from biopharmaceuticals, oil and gas, fuel cell research and chemicals, to medical devices, analytical instrumentation, semiconductor manufacturing, and more. The Brooks product you have just received is of the highest quality available, offering superior performance, reliability and value to the user. It is designed with the ever changing process conditions, accuracy requirements and hostile process environments in mind to provide you with a lifetime of dependable service. We recommend that you read this manual in its entirety. Should you require any additional information concerning Brooks products and services, please contact your local Brooks Sales and Service Office listed on the back cover of this manual or visit www.BrooksInstrument.com Yours sincerely, Brooks Instrument Flow Controllers for Gas and Liquid Service THIS PAGE WAS INTENTIONALLY LEFT BLANK Installation and Operation Manual X-VA-FC-eng Part Number: 541B045AAG December, 2015 Installation and Operation Manual X-VA-FC-eng Part Number: 541B045AAG December, 2015 Contents Flow Controllers for Gas and Liquid Service Paragraph Page Number Number Introduction Section 1 1-1 Description ..................................................................................................................................... 1-1 1-2 Design Features ............................................................................................................................. 1-1 1-3 Specifications ................................................................................................................................. 1-1 Installation Section 2 2-1 General .......................................................................................................................................... 2-1 2-2 Receipt of Equipment ..................................................................................................................... 2-1 2-3 Recommended Storage Practice .................................................................................................... 2-1 2-4 Return Shipment ............................................................................................................................ 2-2 2-5 Transit Precautions ......................................................................................................................... 2-2 2-6 Removal from Storage .................................................................................................................... 2-2 2-7 Installation ...................................................................................................................................... 2-3 2-8 Panel Mounting ............................................................................................................................... 2-3 Operation Section 3 3-1 Operating Precaution ...................................................................................................................... 3-1 3-2 General .......................................................................................................................................... 3-1 Maintenance Section 4 4-1 General .......................................................................................................................................... 4-1 Section A Essential Instructions Essential Instructions ...................................................................................................................... A-1 Warranty, Local Sales/Service Contact Information ....................................................................... Back Cover FIGURES Figure Page Number Number 1-1 Cutaway View, Principle of Operation ............................................................................................. 1-5 1-2 Cutaway View, NRS Valve .............................................................................................................. 1-5 1-3 Cutaway View, cartridge Valve ........................................................................................................ 1-5 1-4 Dimensional Drawing Model FC 8744 ............................................................................................ 1-5 1-5 Dimensional Drawing Models FC 8802 and 8812 ........................................................................... 1-6 1-6 Dimensional Drawing Models FC 8902 and 8912 ........................................................................... 1-6 1-7 Dimensional Drawing Model FC 8842 ............................................................................................ 1-7 1-8 Dimensional Drawing Model FC 8942 ............................................................................................ 1-7 1-9 Dimensional Drawing Model FC 8845 ............................................................................................ 1-8 1-10 Dimensional Drawing Model FC 8945 ............................................................................................ 1-8 1-11 Dimensional Drawing Models FC 8805 and 8815 ........................................................................... 1-9 1-12 Dimensional Drawing Models FC 8905 and 8915 ........................................................................... 1-9 1-13 Dimensional Drawing Model FC 8830 ........................................................................................... 1-10 TABLES Table Page Number Number 1-1 Flow Ranges .................................................................................................................................. 1-3 1-2a Pressure/Temperature Ratings & Pressure Drop............................................................................ 1-3 1-2b Pressure/Temperature Ratings CRN .............................................................................................. 1-3 1-3 Materials of Construction/ Connection/ Valve Option ...................................................................... 1-4 1-4 Model Code ................................................................................................................................... 1-11 1-5 Sizing Chart ................................................................................................................................... 1-13 i Contents Flow Controllers for Gas and Liquid Service THIS PAGE WAS INTENTIONALLY LEFT BLANK ii Installation and Operation Manual X-VA-FC-eng Part Number: 541B045AAG December, 2015 Installation and Operation Manual X-VA-FC-eng Part Number: 541B045AAG December, 2015 Section 1 Introduction Flow Controllers for Gas and Liquid Service 1-1 Description Brooks® flow controllers are designed to maintain a constant differential pressure across an integral, manual flow regulating valve. The incoming fluid pressure on one side of the diaphragm, and outlet pressure plus spring action on the other side, position an internal diaphragm-actuated control valve. Variations in the supply or discharge pressure disturb the balance of forces on the diaphragm, causing the internal control valve to open or close, thus maintaining a fixed differential pressure across the integral, manual flow regulating valve resulting in constant flow. Refer to Figure 1-1. Model FC 8744 controllers are used for accurately adjusting and maintaining small gas and liquid flows with variable downstream pressures. Series FC 8800 controllers are used for accurately adjusting and maintaining liquid and gas flows with variable upstream pressures. Series FC 8900 controllers are used for accurately adjusting and maintaining liquid and gas flows with variable downstream pressures. 1-2 Design Features • Wide range of models for high and low flow rates. • Integral Controller with flowmeter assemblies in a compact size. • Brass or 316 Stainless Steel construction compatible with a wide range of fluids. • Front or Rear Panel Mounting options. • 15 Turn NRSTM(extremely low flow) valve option for more precise control. 1-3 Specifications Flow Ranges Water - up to 480 GPH / 1820 l/h Air - up to 2130 SCFH / 56000 ln/h Refer to Table 1-1. Pressure and Temperature Ratings Up to 1000 psig / 69 bar. Refer to Table 1-2a or 1-2b. Minimum Operating Temperature: -40°F/C. Maximum Operating Temperature: Refer to Tables 2a or 2b. 1-1 Section 1 Introduction Flow Controllers for Gas and Liquid Service Installation and Operation Manual X-VA-FC-eng Part Number: 541B045AAG December, 2015 Pressure Equipment Directive (97/23/EC) Equipment falls under Sound Engineering Practice (SEP) according to the directive. Pressure Drop Refer to Table 1-2a. Materials of Construction Controller Body: 316 Stainless Steel, Brass or Aluminum (FC 8744 only). Refer to Table 1-3. Controller Diaphragm: Buna-N, Teflon® or Viton® fluoroelastomers Refer to Table 1-3. Needle Valve: 1) 316 Stainless Steel Cartridge valve, Refer to Figure 1-3, Refer to DS-VA-CART-eng 2) 316 Stainless Steel NRS Valve, Refer to Figure 1-2, Refer to DS-VA-8503-eng 3) 316 Stainless Steel standard needle valve type Refer to Table 1-3. O-rings: Viton fluoroelastomers Buna-N Kalrez® (SS body only) EPR (SS body only) Kalrez®/Teflon®(SS body only) Refer to Table 1-3. Meter Dimensions Refer to Figures 1-2 thru 1-11. Sizing Refer to Table 1-5. Material Certification: (Stainless Steel body only) Certification to NACE MR-01-75 Certification to DIN 50049-2.2 Certification to DIN 50049-3.1 Ordering Information and Model Codes Refer to Table 1-4. 1-2 Installation and Operation Manual X-VA-FC-eng Part Number: 541B045AAG December, 2015 Section 1 Introduction Flow Controllers for Gas and Liquid Service Table 1-1 Flow Ranges Table 1-2a Pressure/Temperature Ratings and Pressure Drop Table 1-2b Pressure/Temperature Ratings CRN 1-3 Section 1 Introduction Installation and Operation Manual X-VA-FC-eng Part Number: 541B045AAG December, 2015 Flow Controllers for Gas and Liquid Service Table 1-3 Materials of Construction / Connection / Valve Option Model Item Body/Diaphragm/Valve Seat & O-ring Brass/Viton Brass/Buna/Buna-N SS/Teflon SS/Viton Alum/Buna-N Connection Size and Type 1/4" F-NPT 1/8" F-NPT 1/8" Tube Compression 1/4" Tube Compression 1/4" I.D. Hose 3/4" F-NPT Integral 5/16-24 UNF Thd Integral connection for 1350/55 - one end Filter Filter - inlet Filter - inlet & outlet Valve Type Cartridge valve NRS Valve Digital handle NRS Valve High Flow Needle Valve No Valve 00 02 05 12 15 40 42 45 FC 8830 FC 8744 X X X X - X X X X - X - X X X X - X - X X X X - X X X X - X - X X - X X X X X X X X X X X X - X X X X - X X X - X X - X X X X X X X X X X X - X X X X - X - X X X X - X - X - X - X - X - X - X - X - - X X X X X X X X X - X - X X X X X X X X X X - X X X Figure 1-1 Cutaway View, Principle of Operation Figure 1-2 Cutaway View, NRS Valve 1-4 Figure 1-3 Cutaway View, Cartridge Valve Installation and Operation Manual X-VA-FC-eng Part Number: 541B045AAG December, 2015 Section 1 Introduction Flow Controllers for Gas and Liquid Service Figure 1-4 Dimensional Drawing Model FC 8744 Figure 1-5 Dimensional Drawing Models FC 8802 and 8812 1-5 Section 1 Introduction Flow Controllers for Gas and Liquid Service Figure 1-6 Dimensional Drawing Models FC 8902 and 8912 Figure 1-7 Dimensional Drawing Model FC 8842 1-6 Installation and Operation Manual X-VA-FC-eng Part Number: 541B045AAG December, 2015 Installation and Operation Manual X-VA-FC-eng Part Number: 541B045AAG December, 2015 Section 1 Introduction Flow Controllers for Gas and Liquid Service Figure 1-8 Dimensional Drawing Model FC 8942 Figure 1-9 Dimensional Drawing Model FC 8845 1-7 Section 1 Introduction Flow Controllers for Gas and Liquid Service Figure 1-10 Dimensional Drawing Model FC 8945 Figure 1-11 Dimensional Drawing Models FC 8805 and 8815 1-8 Installation and Operation Manual X-VA-FC-eng Part Number: 541B045AAG December, 2015 Installation and Operation Manual X-VA-FC-eng Part Number: 541B045AAG December, 2015 Section 1 Introduction Flow Controllers for Gas and Liquid Service Figure 1-12 Dimensional Drawing Models FC 8905 and 8915 Figure 1-13 Dimensional Drawing Model FC 8830 1-9 Section 1 Introduction Flow Controllers for Gas and Liquid Service Table 1-4 Model Code 1-10 Installation and Operation Manual X-VA-FC-eng Part Number: 541B045AAG December, 2015 Installation and Operation Manual X-VA-FC-eng Part Number: 541B045AAG December, 2015 Section 1 Introduction Flow Controllers for Gas and Liquid Service Table 1-4 Model Code Cont’d 1-11 Section 1 Introduction Flow Controllers for Gas and Liquid Service Table 1-5 Sizing Chart 1-12 Installation and Operation Manual X-VA-FC-eng Part Number: 541B045AAG December, 2015 Installation and Operation Manual X-VA-FC-eng Part Number: 541B045AAG December, 2015 Section 2 Installation Flow Controllers for Gas and Liquid Service 2-1 General This section contains the procedures for the receipt and installation of the instrument. Do not attempt to start the system until the instrument has been permanently installed. It is extremely important that the start-up procedures be followed in the exact sequence presented. 2-2 Receipt of Equipment When the instrument is received, the outside packing case should be checked for damage incurred during shipment. If the packing case is damaged, the local carrier should be notified at once regarding his liability. A report should be submitted to your nearest Product Service Department. Brooks Instrument 407 W. Vine Street P.O. Box 903 Hatfield, PA 19440 USA Toll Free (888) 554 FLOW (3569) Tel (215) 362 3700 Fax (215) 362 3745 E-mail: [email protected] www.BrooksInstrument.com Brooks Instrument Neonstraat 3 6718 WX Ede, Netherlands P.O. Box 428 6710 BK Ede, Netherlands Tel +31 (0) 318 549 300 Fax +31 (0) 318 549 309 E-mail: [email protected] Brooks Instrument 1-4-4 Kitasuna Koto-Ku Tokyo, 136-0073 Japan Tel +81 (0) 3 5633 7100 Fax +81 (0) 3 5633 7101 Email: [email protected] Remove the envelope containing the packing list. Outside of your clean area, carefully remove the equipment from the packing case. Make sure spare parts are not discarded with the packing material. Inspect for damaged or missing parts. 2-3 Recommended Storage Practice If intermediate or long-term storage of equipment is required, it is recommended that the equipment be stored in accordance with the following: a. Within the original shipping container. b. Stored in a sheltered area, preferably a warm, dry, heated warehouse. c. 32°C (90°F)maximum,45°F (7°C) minimum. d. Relative humidity 45% nominal, 60% maximum, 25% minimum. Upon removal from storage a visual inspection should be conducted to verify the condition of equipment is "as received". 2-1 Section 2 Installation Flow Controllers for Gas and Liquid Service Installation and Operation Manual X-VA-FC-eng Part Number: 541B045AAG December, 2015 2-4 Return Shipment Prior to returning any instrument to the factory visit the Brooks website www.BrooksInstrument.com for a Return Materials Authorization Number (RMA#), or contact one of the following locations: Brooks Instrument 407 W. Vine Street P.O. Box 903 Hatfield, PA 19440 USA Toll Free (888) 554 FLOW (3569) Tel (215) 362 3700 Fax (215) 362 3745 E-mail: [email protected] www.BrooksInstrument.com Brooks Instrument Neonstraat 3 6718 WX Ede, Netherlands P.O. Box 428 6710 BK Ede, Netherlands Tel +31 (0) 318 549 300 Fax +31 (0) 318 549 309 E-mail: [email protected] Brooks Instrument 1-4-4 Kitasuna Koto-Ku Tokyo, 136-0073 Japan Tel +81 (0) 3 5633 7100 Fax +81 (0) 3 5633 7101 Email: [email protected] Instrument must have been purged in accordance with the following: All flow instruments returned to Brooks requires completion of Form RPR003-1, Brooks Instrument Decontamination Statement, along with a Material Safety Data Sheet (MSDS) for the fluid(s) used in the instrument. Failure to provide this information will delay processing by Brooks personnel. Copies of these forms can be downloaded from the Brooks website www.BrooksInstrument.com or are available from any Brooks Instrument location listed above. 2-5 Transit Precautions To safeguard against damage during transit, transport the instrument to the installation site in the same container used for transportation from the factory if circumstances permit. 2-6 Removal from Storage 2-2 Upon removal from storage, a visual inspection should be conducted to verify the condition of the equipment is “as received.” If the equipment has been in storage in conditions in excess of those recommended (See Section 2-3), the device should be subjected to a pneumatic pressure test in accordance with applicable vessel codes. Installation and Operation Manual X-VA-FC-eng Part Number: 541B045AAG December, 2015 Section 2 Installation Flow Controllers for Gas and Liquid Service 2-7 Installation The inlet and outlet connections are identified by the terms “in” and “out”. The controller may be installed in any attitude. Care must be exercised to prevent solids from entering the controller. The internal flow area is very small and any foreign material entering the controller will impair the operation of the needle valve and controller. Inlet and outlet filters should be installed. Optional integral micron filter is available for all models except Model FC 8830 2-8 Panel Mounting Series FC 8800 and FC 8900: Optional Mounting Brackets are provided for panel mounting the controller. The brackets are rotatable and adjustable to any desired location. For front panel mounting, two (2) 11/32" diameter and one (1) 21/32" diameter panel openings are required. To front panel mount controller, remove valve knob, valve bonnet and one panel nut (for panel thickness over 1/4" remove both panel nuts). Place the valve stem through the panel opening, install and tighten two mounting nuts. Tighten mounting nuts and valve bonnet. Replace and tighten valve knob. Model FC 8744: Panel mounting nuts are provided on the valve stem for a 17/32" diameter panel cutout. The controller may be mounted in any desired attitude. To panel mount the controller, remove the valve knob, valve bonnet and one panel nut (for the panel thickness of 1/4" remove both panel nuts). Place the valve stem through the panel opening and tighten panel mounting nuts and valve bonnet. replace and tighten valve knob. . 2-3 Section 2 Installation Flow Controllers for Gas and Liquid Service THIS PAGE WAS INTENTIONALLY LEFT BLANK 2-4 Installation and Operation Manual X-VA-FC-eng Part Number: 541B045AAG December, 2015 Installation and Operation Manual X-VA-FC-eng Part Number: 541B045AAG December, 2015 Section 3 Operation Flow Controllers for Gas and Liquid Service 3-1 Operating Precaution 3-2 General Series FC 8800: After the flow controller is installed and the downstream condition established, adjust the upstream pressure to the value required to pass the maximum flow rate desired with the integral valve 90% open. If a flow meter is used it should be installed downstream of the controller where the pressure is constant. Do not attempt to use the valve for shutoff. If tight shut-off is required a separate on-off valve should be installed upstream of the controller. Should the downstream condition change, thus changing the pressure, a proportional change in flow rate will result. Model FC 8744 & Series FC 8900: After the flow controller is installed and the upstream condition established, adjust the downstream pressure to the value required to pass maximum flow rate desired with integral valve 90% open. A good pressure regulator should be installed upstream of the controller. If the supply or upstream pressure varies, the flow rate will vary proportionally. If a flow meter is used for rate indication, install it on the constant pressure or upstream side of the controller. Use a separate valve for tight shut-off, if required. 3-1 Section 3 Operation Flow Controllers for Gas and Liquid Service THIS PAGE WAS INTENTIONALLY LEFT BLANK 3-2 Installation and Operation Manual X-VA-FC-eng Part Number: 541B045AAG December, 2015 Installation and Operation Manual X-VA-FC-eng Part Number: 541B045AAG December, 2015 Section 4 Maintenance Flow Controllers for Gas and Liquid Service 4-1 Maintenance The FC Series Flow Controllers require no maintenance when installed in a dirt-free flow line. Repair or disassembly of the regulator in the field is not recommended. The regulator parts are ultrasonically cleaned and whiteroom assembled for trouble free operation. Do not attempt to clean the regulator by flushing with solvent or air. The optional filter elements should be periodically inspected and ultrasonically cleaned or replaced if necessary. When reinstalling the filter elements use care to prevent any dirt or foreign matter from entering the lines. Should the regulator become inoperative, it should be returned to the factory for repair or replacement. 4-1 Section 4 Maintenance Flow Controllers for Gas and Liquid Service THIS PAGE WAS INTENTIONALLY LEFT BLANK 4-2 Installation and Operation Manual X-VA-FC-eng Part Number: 541B045AAG December, 2015 Section A - Essential Instructions Installation and Operation Manual X-VA-FC-eng Part Number: 541B045AAG December, 2015 Flow Controllers for Gas and Liquid Service Bulgarian Ɉɫɧɨɜɧɢ ɢɧɫɬɪɭɤɰɢɢ ɉɪɨɱɟɬɟɬɟ ɩɪɟɞɢ ɪɚɛɨɬɚ! Brooks Instrument ɩɪɨɟɤɬɢɪɚ, ɩɪɨɢɡɜɟɠɞɚ ɢ ɬɟɫɬɜɚ ɩɪɨɞɭɤɬɢɬɟ ɫɢ ɩɨ ɬɚɤɴɜ ɧɚɱɢɧ, ɱɟ ɬɟ ɞɚ ɨɬɝɨɜɚɪɹɬ ɧɚ ɦɧɨɝɨɛɪɨɣɧɢ ɧɚɰɢɨɧɚɥɧɢ ɢ ɦɟɠɞɭɧɚɪɨɞɧɢ ɫɬɚɧɞɚɪɬɢ. Ɍɟɡɢ ɨɛɨɪɭɞɜɚɧɢɹ ɬɪɹɛɜɚ ɩɪɚɜɢɥɧɨ ɞɚ ɫɟ ɢɧɫɬɚɥɢɪɚɬ, ɟɤɫɩɥɨɚɬɢɪɚɬ ɢ ɩɨɞɞɴɪɠɚɬ ɡɚ ɞɚ ɫɟ ɝɚɪɚɧɬɢɪɚ, ɱɟ ɳɟ ɦɨɝɚɬ ɞɚ ɪɚɛɨɬɹɬ ɫɴɨɬɜɟɬɧɨ ɧɚ ɬɟɯɧɢɬɟ ɧɨɪɦɚɥɧɢ ɫɩɟɰɢɮɢɤɚɰɢɢ. ɋɥɟɞɜɚɳɢɬɟ ɢɧɫɬɪɭɤɰɢɢ ɬɪɹɛɜɚ ɞɚ ɫɟ ɫɩɚɡɜɚɬ ɢ ɬɪɹɛɜɚ ɞɚ ɫɟ ɜɤɥɸɱɚɬ ɜ ɩɪɨɝɪɚɦɚɬɚ ɡɚ ɛɟɡɨɩɚɫɧɨɫɬ ɧɚ ɬɪɭɞɚ ɩɪɢ ɢɧɫɬɚɥɢɪɚɧɟɬɨ, ɟɤɫɩɥɨɚɬɚɰɢɹɬɚ ɢ ɩɨɞɞɪɴɠɤɚɬɚ ɧɚ ɩɪɨɞɭɤɬɢɬɟ ɧɚ Brooks Instrument. x Ɂɚ ɞɚ ɫɟ ɝɚɪɚɧɬɢɪɚ ɯɚɪɚɤɬɟɪɧɚɬɚ ɩɪɨɢɡɜɨɞɢɬɟɥɧɨɫɬ, ɢɧɫɬɚɥɢɪɚɧɟɬɨ, ɟɤɫɩɥɨɚɬɚɰɢɹɬɚ, ɚɤɬɭɚɥɢɡɢɪɚɧɟɬɨ, ɩɪɨɝɪɚɦɢɪɚɧɟɬɨ ɢ ɩɨɞɞɪɴɠɤɚɬɚ ɧɚ ɩɪɨɞɭɤɬɚ ɬɪɹɛɜɚ ɞɚ ɫɟ ɢɡɜɴɪɲɜɚɬ ɫɚɦɨ ɨɬ ɤɜɚɥɢɮɢɰɢɪɚɧ ɩɟɪɫɨɧɚɥ. x ɉɪɨɱɟɬɟɬɟ ɜɫɢɱɤɢ ɢɧɫɬɪɭɤɰɢɢ ɩɪɟɞɢ ɢɧɫɬɚɥɢɪɚɧɟɬɨ, ɟɤɫɩɥɨɚɬɚɰɢɹɬɚ ɢ ɩɨɞɞɪɴɠɤɚɬɚ ɧɚ ɩɪɨɞɭɤɬɚ. Ⱥɤɨ ɬɨɜɚ ɪɴɤɨɜɨɞɫɬɜɨ ɧɟ ɟ ɫɴɨɬɜɟɬɫɬɜɚɳɨɬɨ ɢɡɞɚɧɢɟ, ɜɢɠɬɟ ɧɚ ɡɚɞɧɚɬɚ ɨɛɥɨɠɤɚ ɢɧɮɨɪɦɚɰɢɹɬɚ ɡɚ ɤɨɧɬɚɤɬ ɫ ɦɟɫɬɧɢɹ ɬɴɪɝɨɜɫɤɢ ɨɮɢɫ. Ɂɚɩɚɡɟɬɟ ɬɨɜɚ ɪɴɤɨɜɨɞɫɬɜɨ ɡɚ ɩɨ-ɤɴɫɧɨ ɢɧɮɨɪɦɢɪɚɧɟ. ȼɇɂɆȺɇɂȿ: ɇɟ ɪɚɛɨɬɟɬɟ ɫ ɨɛɨɪɭɞɜɚɧɟɬɨ ɢɡɜɴɧ ɞɢɚɩɚɡɨɧɢɬɟ, ɭɤɚɡɚɧɢ ɜ ɢɧɫɬɪɭɤɰɢɹɬɚ ɢ ɪɴɤɨɜɨɞɫɬɜɨɬɨ ɩɨ ɟɤɫɩɥɨɚɬɚɰɢɹ. ɇɟɢɡɩɴɥɧɟɧɢɟɬɨ ɧɚ ɬɨɜɚ ɦɨɠɟ ɞɚ ɞɨɜɟɞɟ ɞɨ ɫɟɪɢɨɡɧɢ ɬɟɥɟɫɧɢ ɩɨɜɪɟɞɢ ɢ / ɢɥɢ ɩɨɜɪɟɠɞɚɧɟ ɧɚ ɨɛɨɪɭɞɜɚɧɟɬɨ. x Ⱥɤɨ ɧɟ ɪɚɡɛɢɪɚɬɟ ɧɹɤɨɢ ɢɧɫɬɪɭɤɰɢɢɬɟ, ɫɜɴɪɠɟɬɟ ɫɟ ɫ ɩɪɟɞɫɬɚɜɢɬɟɥɹ ɧɚ Brooks Instrument ɡɚ ɢɡɹɫɧɹɜɚɧɟ ɧɚ ɩɪɨɛɥɟɦɚ. x ɋɩɚɡɜɚɣɬɟ ɜɫɢɱɤɢ ɩɪɟɞɭɩɪɟɠɞɟɧɢɹ, ɩɪɢɡɨɜɢ ɢ ɢɧɫɬɪɭɤɰɢɢ ɨɡɧɚɱɟɧɢ ɜɴɪɯɭ ɨɛɨɪɭɞɜɚɧɟɬɨ ɢɥɢ ɞɨɫɬɚɜɟɧɢ ɡɚɟɞɧɨ ɫ ɧɟɝɨ. x ɂɧɫɬɚɥɢɪɚɣɬɟ ɨɛɨɪɭɞɜɚɧɟɬɨ ɫɴɨɬɜɟɬɧɨ ɧɚ ɭɤɚɡɚɧɢɹɬɚ ɜ ɢɧɫɬɪɭɤɰɢɹɬɚ ɡɚ ɢɧɫɬɚɥɢɪɚɧɟ ɢ ɧɚ ɞɟɣɫɬɜɚɳɢɬɟ ɧɚ ɦɟɫɬɧɢ ɢ ɧɚɰɢɨɧɚɥɧɢ ɩɪɟɞɩɢɫɚɧɢɹ. ɋɜɴɪɡɜɚɣɬɟ ɩɪɨɞɭɤɬɢɬɟ ɫɚɦɨ ɤɴɦ ɩɨɞɯɨɞɹɳɢ ɢɡɬɨɱɧɢɰɢ ɧɚ ɟɥɟɤɬɪɢɱɟɫɬɜɨ ɢ ɧɚɥɹɝɚɧɟ. x ɏɨɞ: (1) Ȼɚɜɧɨ ɜɴɜɟɞɟɬɟ ɫɢɫɬɟɦɚɬɚ ɩɨɞ ɧɚɥɹɝɚɧɟ. Ȼɚɜɧɨ ɨɬɜɨɪɟɬɟ ɪɚɛɨɬɧɢɬɟ ɤɥɚɩɚɧɢ ɡɚ ɞɚ ɫɟ ɢɡɛɟɝɧɚɬ ɤɨɥɟɛɚɧɢɹɬɚ ɧɚ ɩɨɬɨɤɚ. (2) ɉɪɨɜɟɪɟɬɟ ɞɚɥɢ ɧɹɦɚ ɢɡɬɢɱɚɧɟ ɩɪɢ ɜɯɨɞɧɨɬɨ ɢ ɢɡɯɨɞɧɨɬɨ ɫɴɟɞɢɧɟɧɢɟ ɧɚ ɪɚɡɯɨɞɨɦɟɪɚ. Ⱥɤɨ ɧɹɦɚ ɢɡɬɢɱɚɧɟ, ɧɚɩɴɥɧɟɬɟ ɫɢɫɬɟɦɚɬɚ ɞɨ ɪɚɛɨɬɧɨ ɧɚɥɹɝɚɧɟ. x ɉɪɟɞɢ ɢɡɜɴɪɲɜɚɧɟ ɧɚ ɩɨɞɞɪɴɠɤɚɬɚ ɧɟɩɪɟɦɟɧɧɨ ɩɪɨɜɟɪɟɬɟ ɞɚɥɢ ɪɚɛɨɬɧɢɹɬ ɬɪɴɛɨɩɪɨɜɨɞ ɧɟ ɫɟ ɧɚɦɢɪɚ ɩɨɞ ɧɚɥɹɝɚɧɟ. Ⱥɤɨ ɫɚ ɧɟɨɛɯɨɞɢɦɢ ɪɟɡɟɪɜɧɢ ɱɚɫɬɢ, ɫ ɨɩɪɟɞɟɥɟɧɢɬɟ ɨɬ Brooks Instrument ɪɟɡɟɪɜɧɢ ɱɚɫɬɢ ɬɪɹɛɜɚ ɞɚ ɛɨɪɚɜɢ ɫɚɦɨ ɤɜɚɥɢɮɢɰɢɪɚɧ ɩɟɪɫɨɧɚɥ. ɇɟɪɚɡɪɟɲɟɧɢɬɟ ɱɚɫɬɢ ɢ ɩɪɨɰɟɞɭɪɢ ɦɨɝɚɬ ɞɚ ɨɤɚɠɚɬ ɜɥɢɹɧɢɟ ɜɴɪɯɭ ɪɚɛɨɬɚɬɚ ɧɚ ɩɪɨɞɭɤɬɚ, ɢ ɫɴɳɨ ɞɚ ɡɚɫɬɪɚɲɚɬ ɛɟɡɨɩɚɫɧɨɫɬɬɚ ɧɚ ɟɤɫɩɥɨɚɬɚɰɢɹɬɚ. Ɂɚɦɟɫɬɜɚɧɟɬɨ ɫ ɧɟɨɪɢɝɢɧɚɥɧɢ ɱɚɫɬɢ ɦɨɠɟ ɞɚ ɞɨɜɟɞɟ ɞɨ ɩɨɠɚɪ, ɨɩɚɫɧɨɫɬ ɨɬ ɬɨɤɨɜ ɭɞɚɪ ɢɥɢ ɧɟɩɪɚɜɢɥɧɚ ɪɚɛɨɬɚ. x ȼɫɢɱɤɢ ɜɪɚɬɢ ɧɚ ɨɛɨɪɭɞɜɚɧɟɬɨ ɧɟɩɪɟɦɟɧɧɨ ɞɚ ɛɴɞɚɬ ɡɚɬɜɨɪɟɧɢ, ɚ ɡɚɳɢɬɧɢɬɟ ɩɨɤɪɢɬɢɹ ɞɚ ɛɴɞɚɬ ɧɚ ɦɹɫɬɨɬɨ ɫɢ, ɡɚ ɞɚ ɫɟ ɢɡɛɟɝɧɚɬ ɬɨɤɨɜɢɬɟ ɭɞɚɪɢ ɢ ɬɟɥɟɫɧɢɬɟ ɩɨɜɪɟɞɢ, ɨɫɜɟɧ ɚɤɨ ɤɜɚɥɢɮɢɰɢɪɚɧɢ ɫɩɟɰɢɚɥɢɫɬɢ ɢɡɜɴɪɲɜɚɬ ɪɚɛɨɬɢ ɩɨ ɧɟɝɨɜɨɬɨ ɩɨɞɞɴɪɠɚɧɟ. ȼɇɂɆȺɇɂȿ: ɉɪɢ ɨɛɨɪɭɞɜɚɧɢɹɬɚ ɫ ɩɪɨɬɢɱɚɳɢ ɬɟɱɧɨɫɬɢ, ɚɤɨ ɩɨ ɧɹɤɚɤɜɚ ɩɪɢɱɢɧɚ ɟ ɧɟɨɛɯɨɞɢɦɨ ɞɚ ɫɟ ɡɚɬɜɨɪɹɬ ɧɚɦɢɪɚɳɢɬɟ ɫɟ ɞɨ ɨɛɨɪɭɞɜɚɧɟɬɨ ɢɡɯɨɞɧɢ ɢ ɜɯɨɞɧɢ ɤɥɚɩɚɧɢ, ɨɛɨɪɭɞɜɚɧɟɬɨ ɬɪɹɛɜɚ ɧɚɩɴɥɧɨ ɞɚ ɫɟ ɢɡɩɪɚɡɧɢ. ɇɟɢɡɩɴɥɧɟɧɢɟɬɨ ɧɚ ɬɨɜɚ ɦɨɠɟ ɞɚ ɩɪɢɱɢɧɢ ɬɨɩɥɢɧɧɨ ɪɚɡɲɢɪɟɧɢɟ ɧɚ ɬɟɱɧɨɫɬɬɚ, ɤɨɟɬɨ ɦɨɠɟ ɞɨ ɫɩɭɤɚ ɨɛɨɪɭɞɜɚɧɟɬɨ ɢ ɞɚ ɞɨɜɟɞɟ ɞɨ ɬɟɥɟɫɧɢ ɩɨɜɪɟɞɢ. ȿɜɪɨɩɟɣɫɤɚ ɞɢɪɟɤɬɢɜɚ ɡɚ ɭɪɟɞɢ ɩɨɞ ɧɚɥɹɝɚɧɟ (PED) ȼɫɢɱɤɢ ɫɴɨɪɴɠɟɧɢɹ ɩɨɞ ɧɚɥɹɝɚɧɟ ɫ ɜɴɬɪɟɲɧɨ ɧɚɥɹɝɚɧɟ ɧɚɞ 0,5 bar (g) ɢ ɫ ɪɚɡɦɟɪ ɩɨ-ɝɨɥɹɦ ɨɬ 25 mm ɢɥɢ 1" (ɢɧɱ), ɩɨɩɚɞɚɬ ɩɨɞ ɞɟɣɫɬɜɢɟɬɨ ɧɚ ɟɜɪɨɩɟɣɫɤɚɬɚ ɞɢɪɟɤɬɢɜɚ ɡɚ ɭɪɟɞɢ ɩɨɞ ɧɚɥɹɝɚɧɟ (PED). x Ƚɥɚɜɚ „Ɍɟɯɧɢɱɟɫɤɢ ɞɚɧɧɢ” ɧɚ ɧɚɫɬɨɹɳɨɬɨ ɪɴɤɨɜɨɞɫɬɜɨ ɫɴɞɴɪɠɚ ɫɜɴɪɡɚɧɢɬɟ ɫ ɞɢɪɟɤɬɢɜɚɬɚ PED ɢɧɫɬɪɭɤɰɢɢ. x ɍɤɚɡɚɧɢɬɟ ɜ ɧɚɫɬɨɹɳɨɬɨ ɪɴɤɨɜɨɞɫɬɜɨ ɢɡɦɟɪɢɬɟɥɧɢ ɭɪɟɞɢ ɫɴɨɬɜɟɬɫɬɜɚɬ ɧɚ ɟɜɪɨɩɟɣɫɤɚɬɚ ɞɢɪɟɤɬɢɜɚ 97/23/ȿɈ. x ȼɫɢɱɤɢ ɪɚɡɯɨɞɨɦɟɪɢ ɧɚ Brooks Instrument ɫɟ ɨɬɧɚɫɹɬ ɤɴɦ ɮɥɭɢɞɢ ɨɬ ɝɪɭɩɚ 1. x ɂɡɦɟɪɢɬɟɥɧɢɬɟ ɭɪɟɞɢ ɩɨ-ɝɨɥɟɦɢ ɨɬ 25 mm ɢɥɢ 1" (ɢɧɱ) ɫɴɨɬɜɟɬɫɬɜɚɬ ɧɚ I, II ɢɥɢ III ɤɚɬɟɝɨɪɢɹ ɫɩɨɪɟɞ PED. x ɂɡɦɟɪɢɬɟɥɧɢɬɟ ɭɪɟɞɢ ɫ ɪɚɡɦɟɪɢ 25 mm ɢɥɢ 1" (ɢɧɱ), ɢɥɢ ɩɨ-ɦɚɥɤɢ, ɫɥɟɞɜɚɬ ɞɨɛɪɚɬɚ ɢɧɠɟɧɟɪɧɚ ɩɪɚɤɬɢɤɚ (SEP). ȿɜɪɨɩɟɣɫɤɚ ɞɢɪɟɤɬɢɜɚ ɡɚ ɟɥɟɤɬɪɨɦɚɝɧɢɬɧɚ ɫɴɜɦɟɫɬɢɦɨɫɬ (EMC) ɇɨɫɟɳɨɬɨ ɡɧɚɤɚ ɋȿ (ɟɥɟɤɬɪɢɱɟɫɤɨ/ɟɥɟɤɬɪɨɧɧɨ) ɨɛɨɪɭɞɜɚɧɟ ɧɚ Brooks Instrument ɟ ɢɡɩɴɥɧɢɥɨ ɭɫɩɟɲɧɨ ɬɟɫɬɨɜɟɬɟ ɡɚ ɩɪɨɜɟɪɤɚ ɧɚ ɢɡɢɫɤɜɚɧɢɹɬɚ ɡɚ ɟɥɟɤɬɪɨɦɚɝɧɢɬɧɚ ɫɴɜɦɟɫɬɢɦɨɫɬ (ɞɢɪɟɤɬɢɜɚ EMC 2004/108/EC). Ɉɫɨɛɟɧɨ ɜɧɢɦɚɧɢɟ ɬɪɹɛɜɚ ɞɚ ɫɟ ɨɛɪɴɳɚ ɨɛɚɱɟ ɧɚ ɢɡɛɢɪɚɧɟɬɨ ɧɚ ɫɢɝɧɚɥɧɢɬɟ ɤɚɛɟɥɢ, ɢɡɩɨɥɡɜɚɧɢ ɫ ɨɛɨɪɭɞɜɚɧɟɬɨ, ɧɨɫɟɳɨ ɡɧɚɤɚ ɋȿ. Ʉɚɱɟɫɬɜɨ ɧɚ ɫɢɝɧɚɥɧɢɬɟ ɤɚɛɟɥɢ, ɤɚɛɟɥɧɢɬɟ ɫɚɥɧɢɰɢ ɢ ɫɴɟɞɢɧɢɬɟɥɢ: Brooks Insturment ɩɪɟɞɥɚɝɚ ɜɢɫɨɤɨɤɚɱɟɫɬɜɟɧɢ ɤɚɛɟɥɢ, ɨɬɝɨɜɚɪɹɳɢ ɧɚ ɢɡɢɫɤɜɚɧɢɹɬɚ ɧɚ CE ɫɟɪɬɢɮɢɤɚɰɢɹɬɚ. Ⱥɤɨ ɢɡɩɨɥɡɜɚɬɟ ɫɨɛɫɬɜɟɧ ɫɢɝɧɚɥɟɧ ɤɚɛɟɥ, ɬɪɹɛɜɚ ɞɚ ɢɡɛɟɪɟɬɟ ɬɚɤɴɜ, ɤɨɣɬɨ ɟ ɧɚɩɴɥɧɨ ɡɚɳɢɬɟɧ ɫɴɫ 100%-ɨɜɨ ɟɤɪɚɧɢɪɚɧɟ. ɋɴɟɞɢɧɢɬɟɥɢɬɟ ɬɢɩ „D” ɢɥɢ „ɤɪɴɝɨɜ” ɬɪɹɛɜɚ ɞɚ ɛɴɞɚɬ ɟɤɪɚɧɢɪɚɧɢ ɫ ɦɟɬɚɥɟɧ ɳɢɬ. ɉɪɢ ɧɟɨɛɯɨɞɢɦɨɫɬ ɡɚ ɮɢɤɫɢɪɚɧɟɬɨ ɧɚ ɳɢɬɚ ɧɚ ɤɚɛɟɥɚ ɬɪɹɛɜɚ ɞɚ ɫɟ ɢɡɩɨɥɡɜɚɬ ɦɟɬɚɥɧɢ ɤɚɛɟɥɧɢ ɫɚɥɧɢɰɢ. ɓɢɬɴɬ ɧɚ ɤɚɛɟɥɚ ɬɪɹɛɜɚ ɞɚ ɫɟ ɫɜɴɪɠɟ ɫ ɦɟɬɚɥɧɨɬɨ ɩɨɤɪɢɬɢɟ ɢɥɢ ɦɟɬɚɥɧɢɹ ɫɚɥɧɢɤ ɢ ɜ ɞɜɚɬɚ ɤɪɚɹ ɞɚ ɫɟ ɟɤɪɚɧɢɪɚ ɜ 360°. ɓɢɬɴɬ ɬɪɹɛɜɚ ɞɚ ɛɴɞɟ ɡɚɡɟɦɟɧ. ɋɴɟɞɢɧɢɬɟɥɢɬɟ ɡɚ ɩɟɱɚɬɧɢ ɩɥɚɬɤɢ ɫɚ ɫɬɚɧɞɚɪɬɧɨ ɧɟɦɟɬɚɥɧɢ. ɂɡɩɨɥɡɜɚɧɢɬɟ ɤɚɛɟɥɢ ɬɪɹɛɜɚ ɞɚ ɛɴɞɚɬ ɡɚɳɢɬɟɧɢ ɫɴɫ 100%-ɨɜɨ ɟɤɪɚɧɢɪɚɧɟ, ɡɚ ɞɚ ɨɬɝɨɜɚɪɹɬ ɧɚ CE ɫɟɪɬɢɮɢɤɚɰɢɹɬɚ. ɓɢɬɴɬ ɬɪɹɛɜɚ ɞɚ ɛɴɞɟ ɡɚɡɟɦɟɧ. Ʉɨɧɮɢɝɭɪɚɰɢɹ ɧɚ ɤɨɧɬɚɤɬɢɬɟ: ȼɢɠ ɩɪɢɥɨɠɟɧɚɬɚ ɢɧɫɬɪɭɤɰɢɹ ɡɚ ɟɤɫɩɥɨɚɬɚɰɢɹ. ȿɥɟɤɬɪɨɫɬɚɬɢɱɟɧ ɪɚɡɪɹɞ (ESD) ȼɇɂɆȺɇɂȿ: ɉɪɢɛɨɪɴɬ ɫɴɞɴɪɠɚ ɟɥɟɤɬɪɨɧɧɢ ɤɨɦɩɨɧɟɧɬɢ, ɤɨɢɬɨ ɫɚ ɱɭɜɫɬɜɢɬɟɥɧɢ ɤɴɦ ɫɬɚɬɢɱɧɨɬɨ ɟɥɟɤɬɪɢɱɟɫɬɜɨ ɢ ɦɨɝɚɬ ɞɚ ɫɟ ɩɨɜɪɟɞɹɬ ɨɬ ɧɟɝɨ. Ɍɪɹɛɜɚ ɞɚ ɫɟ ɫɩɚɡɜɚɬ ɫɴɨɬɜɟɬɧɢɬɟ ɩɪɨɰɟɞɭɪɢ ɩɨ ɜɪɟɦɟ ɧɚ ɢɡɜɚɠɞɚɧɟ, ɫɥɚɝɚɧɟ ɢɥɢ ɞɪɭɝɨ ɛɨɪɚɜɟɧɟ ɫ ɜɴɬɪɟɲɧɢɬɟ ɦɨɧɬɚɠɧɢ ɩɥɚɬɤɢ ɢ ɭɫɬɪɨɣɫɬɜɚ. ɉɪɨɰɟɞɭɪɚ ɡɚ ɪɚɛɨɬɚ: 1. ɂɡɤɥɸɱɟɬɟ ɨɛɨɪɭɞɜɚɧɟɬɨ. 2. ɉɟɪɫɨɧɚɥɴɬ ɬɪɹɛɜɚ ɞɚ ɫɟ ɡɚɡɟɦɢ ɫ ɝɪɢɜɧɚ ɢɥɢ ɞɪɭɝɨ ɛɟɡɨɩɚɫɧɨ ɢ ɩɨɞɯɨɞɹɳɨ ɡɚ ɰɟɥɬɚ ɫɪɟɞɫɬɜɨ, ɩɪɟɞɢ ɞɚ ɢɧɫɬɚɥɢɪɚ, ɢɡɜɚɠɞɚ ɢɥɢ ɪɟɝɭɥɢɪɚ ɦɨɧɬɚɠɧɚ ɩɥɚɬɤɚ ɢɥɢ ɞɪɭɝɨ ɜɴɬɪɟɲɧɨ ɭɫɬɪɨɣɫɬɜɨ. 3. ɉɟɱɚɬɧɢɬɟ ɦɨɧɬɚɠɧɢ ɩɥɚɬɤɢ ɬɪɹɛɜɚ ɞɚ ɫɟ ɬɪɚɧɫɩɨɪɬɢɪɚɬ ɜ ɩɪɨɜɨɞɹɳɚ ɨɩɚɤɨɜɤɚ. ɉɟɱɚɬɧɢɬɟ ɩɥɚɬɤɢ ɦɨɝɚɬ ɞɚ ɫɟ ɢɡɜɚɠɞɚɬ ɨɬ ɡɚɳɢɬɧɨɬɨ ɩɨɤɪɢɬɢɟ ɫɚɦɨ ɧɟɩɨɫɪɟɞɫɬɜɟɧɨ ɩɪɟɞɢ ɢɧɫɬɚɥɢɪɚɧɟɬɨ. Ɉɬɫɬɪɚɧɟɧɢɬɟ ɩɟɱɚɬɧɢ ɩɥɚɬɤɢ ɧɟɡɚɛɚɜɧɨ ɬɪɹɛɜɚ ɞɚ ɫɟ ɫɥɨɠɚɬ ɜ ɡɚɳɢɬɧɚ ɨɩɚɤɨɜɤɚ, ɫɥɭɠɟɳɚ ɡɚ ɬɪɚɧɫɩɨɪɬɢɪɚɧɟ, ɫɤɥɚɞɢɪɚɧɟ ɢɥɢ ɜɪɴɳɚɧɟ ɧɚ ɩɪɨɢɡɜɨɞɢɬɟɥɹ. Ɂɚɛɟɥɟɠɤɢ: ɇɟ ɟ ɭɧɢɤɚɥɧɨ ɹɜɥɟɧɢɟ, ɱɟ ɬɨɡɢ ɩɪɢɛɨɪ ɫɴɞɴɪɠɚ ɱɭɜɫɬɜɢɬɟɥɧɢ ɤɴɦ ɟɥɟɤɬɪɨɫɬɚɬɢɱɧɢɹ ɡɚɪɹɞ (ESD) ɤɨɦɩɨɧɟɧɬɢ. Ȼɨɥɲɢɧɫɬɜɨɬɨ ɨɬ ɫɴɜɪɟɦɟɧɧɢɬɟ ɟɥɟɤɬɪɨɧɧɢ ɩɪɢɛɨɪɢ ɫɴɞɴɪɠɚɬ ɤɨɦɩɨɧɟɧɬɢ, ɢɡɝɨɬɜɟɧɢ ɩɨ ɬɟɯɧɨɥɨɝɢɹ ɦɟɬɚɥ-ɨɤɢɫ (NMOS, SMOS ɢ ɬ.ɧ.). Ɉɩɢɬɴɬ ɞɨɤɚɡɜɚ, ɱɟ ɞɚɠɟ ɢ ɦɚɥɤɨ ɤɨɥɢɱɟɫɬɜɨ ɫɬɚɬɢɱɟɫɤɨ ɟɥɟɤɬɪɢɱɟɫɬɜɨ ɦɨɠɟ ɞɚ ɩɨɜɪɟɞɢ ɢɥɢ ɫɴɫɢɩɟ ɬɟɡɢ ɩɪɢɛɨɪɢ. ɉɨɜɪɟɞɟɧɢɬɟ ɤɨɦɩɨɧɟɧɬɢ ɞɚɠɟ ɚɤɨ ɩɪɢɜɢɞɧɨ ɪɚɛɨɬɹɬ ɩɪɚɜɢɥɧɨ, ɩɪɨɹɜɹɜɚɬ ɧɚɱɚɥɧɢ ɧɟɢɡɩɪɚɜɧɨɫɬɢ. A-1 Section A - Essential Instructions Installation and Operation Manual Flow Controllers for Gas and Liquid Service X-VA-FC-eng Part Number: 541B045AAG December, 2015 Czech Základní instrukce PĜed instalací si pĜeþtČte následující instrukce! Spoleþnost Brooks Instrument konstruuje, vyrábí a testuje tento produkt tak, aby splnil mnoho národních a mezinárodních standardĤ. PĜístroje musí být ĜádnČ nainstalovány, používány a udržovány tak, aby byl zajištČn jejich nepĜetržitý provoz v rámci normálních technických specifikací. Musíte dodržovat následující pokyny a integrovat jejich obsah do svého bezpeþnostního programu pĜi instalování, používání a udržování produktĤ spoleþnosti Brooks. x Pro zajištČní správné funkce zaĜízení mohou jeho instalaci, obsluhu, programování, údržbu a aktualizace firmwaru provádČt výhradnČ kvalifikované osoby. x PĜed instalací, provozem a údržbou produktu si prostudujte všechny pokyny. Pokud tato pĜíruþka není tou správnou pĜíruþkou pro dané zaĜízení, informujte se na zadní stranČ obálky o kontaktu na místní prodejní kanceláĜ. Uchovejte si tuto pĜíruþku pro pozdČjší potĜebu. UPOZORNċNÍ: Neprovozujte zaĜízení v rozsahu mimo daný rozsah v provozní pĜíruþce. Porušení tohoto upozornČní mĤže mít za následek vážné újmy na zdraví a vést k poškození zaĜízení. x x x x x x Pokud nČkterým pokynĤm nerozumíte, kontaktujte svého prodejního zástupce spoleþnosti Brooks a vyžádejte si objasnČní. Dodržujte všechny výstrahy, upozornČní a pokyny, uvedené a vyznaþené na produktu, nebo s ním dodané. Namontujte zaĜízení specifikovaným zpĤsobem podle správné montážní pĜíruþky a podle platných místních a národních pĜedpisĤ. PĜipojte všechny produkty ke správným zdrojĤm elektrické energie a stlaþených médií. Postup: (1) Pomalu do systému pĜivádČjte médium. Pro zabránČní vzniku rázĤ v systému otvírejte procesní ventily postupnČ. (2) PĜekontrolujte tČsnost vstupního a výstupního pĜipojení prĤtokomČru. Pokud nezjistíte žádné netČsnosti, postupnČ zvedejte tlak na provozní hodnotu. PĜed provádČním servisních prací zkontrolujte, zda systém není pod tlakem. V pĜípadČ potĜeby výmČny dílĤ zajistČte, aby byly použity náhradní souþásti specifikované spoleþností Brooks Instrument a výmČnu provádČla kvalifikovaná osoba. Použití neschválených dílĤ a postupĤ mĤže negativnČ ovlivnit efektivitu a bezpeþnost procesu. Použití náhrad za originální díly mĤže zpĤsobit požár, úraz elektrickým proudem nebo nesprávnou funkci. Pokud není zrovna provádČna údržba kvalifikovanou osobou, ujistČte se, že zaĜízení je opatĜeno všemi pĜedepsanými kryty. UPOZORNċNÍ: Pokud je u zaĜízení s prĤtokem kapalin nutno z jakéhokoli dĤvodu uzavĜít vstupní a výstupní ventily, je nutné zaĜízení kompletnČ vyprázdnit. Pokud tak neuþiníte, mĤže z dĤvodu teplotní roztažnosti zbytkĤ média v zaĜízení dojít k jeho poškození nebo k ohrožení zdraví osob. Evropská smČrnice pro tlakové zaĜízení (PED) Na veškerá tlaková zaĜízení s vnitĜním tlakem vyšším než 0,5 baru (g) a velikosti vČtší než 25 mm nebo 1" (palec) se vztahuje platnost smČrnice o tlakovém zaĜízení (PED). Kapitola „Technické údaje“ v této pĜíruþce obsahuje dĤležité bezpeþnostní a provozní pokyny související se smČrnicí PED. x MČĜicí pĜístroje popsané v této pĜíruþce jsou v souladu se smČrnicí EN 97/23/ES. x Všechny prĤtokomČry spoleþnosti Brooks Instrument spadají do rámce Kapaliny, skupina I. x MČĜicí pĜístroje vČtší než 25 mm nebo 1" (palec) jsou v souladu se smČrnicí PED, kategorii I, II nebo III x MČĜicí pĜístroje s velikostí 25 mm nebo 1" (palec) a menší spadají do rámce Správných technických postupĤ (SEP). Evropská smČrnice pro elektromagnetickou kompatibilitu (EMC) Elektrické/elektronické zaĜízení Brooks Instrument nesoucí znaþku CE bylo úspČšnČ testováno dle pĜedpisĤ pro elektromagnetickou kompatibilitu (smČrnice EMC þ. 2004/108/EC). VýbČru signálních kabelĤ pro použití se zaĜízením oznaþeném CE je nutné vČnovat zvláštní pozornost. Kvalita signálních kabelĤ, kabelových prĤchodek a konektorĤ: Brooks Instrument dodává vysoce jakostní kabely splĖující požadavky kvalitativního zaĜazení CE. Pokud chcete použít vlastní signální kabely, zvolte typy s kvalitním stínČním všech žil a v celé délce trasy. V pĜípadČ použití konektorĤ kruhových nebo tvaru „D“, musí mít tyto kovové stínČní. V pĜípadČ jejich použití, musí kovové kabelové prĤchodky být propojeny se stínČním kabelu. StínČní by mČlo být pĜipojené ke kovovému tČlesu pĜístroje nebo krytu, na obou koncích kabelu a po celém jeho obvodu. StínČní by mČlo být uzemnČno. PĜípojky vedoucí ke kartám podle norem jsou nekovová. Pro splnČní požadavkĤ pĜedpisĤ CE musí být použité kabely kompletnČ stínČny. StínČní by mČlo být uzemnČno. Konfigurace kontaktĤ je uvedena v pĜiloženém návodu k obsluze. Elektrostatický výboj (ESD) UPOZORNċNÍ: Tento pĜístroj obsahuje komponenty citlivé na poškození statickou elektĜinou. PĜi montáži, demontáži þi jiné manipulaci s vnitĜními elektronickými obvody je potĜeba dodržovat pĜíslušné postupy. Postup ošetĜování: 1. Odpojte pĜístroj od napájení. 2. Osoba provádČjící údržbu má být pĜi instalaci, vyjímání þi práci na desce plošných spojĤ nebo jiné vnitĜní elektronice uzemnČna zemnícím náramkem, nebo jiným vyhovujícím zpĤsobem. 3. Desky plošných spojĤ je nutné pĜepravovat v elektricky vodivém obalu. Plošné spoje vyjímejte z vodivého obalu až bezprostĜednČ pĜed instalací do pĜístroje! Plošné spoje vyjmuté z pĜístroje a urþené pro další využití, opČt neprodlenČ umístČte do ochranného obalu. Poznámky: Existence prvkĤ, citlivé na elektrostatické výboje (ESD) v pĜístrojích je þastým jevem. Prvky s technologií oxidu kovĤ (NMOS,SMOS) jsou používány u vČtšiny moderních elektronických zaĜízení. Zkušenosti dokazují, že i jen malé elektrostatické výboje mohou poškodit nebo zniþit tyto zaĜízení. U poškozených souþástek, jakkoli zdánlivČ pracujících bezchybnČ, dochází brzy k poruše. A-2 Installation and Operation Manual X-VA-FC-eng Part Number: 541B045AAG December, 2015 Section A - Essential Instructions Flow Controllers for Gas and Liquid Service Dansk Grundlæggende vejledninger Læs disse før anvendelse! Brooks Instruments designer, fremstiller og afprøver sine produkter således, at de tilpasser sig både de indenrigs og internationale standarder. Disse udstyr bør installeres, bruges og repareres omhyggeligt, så at de kan virke tilsvarende deres normale anvendelsesperiode. De følgende regler skal overholdes og implementeres under installeringen samt ved brug og reparation. x For at garantere den passende kapacitet, er udstyrets installation, anvendelse, opdatering, programmering kun tilladt for kvalificeret personale. Alle vejledninger skal læses før produktets installation, anvendelse og reparation. x Hvis denne manual ikke er den passende udgave, kontakt venligst jeres leverandør for yderligere information. x Det anbefales at gemme denne manual for senere brug. OBS.: Udstyret må ikke anvendes til andet end det er angivet i brugsanvisningen. Hvis denne regel brydes, kan der forekomme alvorlige personskader eller brist på udstyret. Hvis vejledningerne ikke er forståelig, kontakt venligst Deres Brooks repræsentant for at afklare problemet som er opstået. x Overhold alle regler, som er markeret eller leveret sammen med udstyret. x Installer udstyret efter den angivne installationsvejledning og gældende lovgivning for anvendelsesområde. Udstyret må kun tilsluttes med kabler og stik som overholder kravspecifikationerne i vejledningen. x Ibrugtagning: (1) Åbn langsomt for trykket i systemet.. Åbn langsomt for alle procesventiler for at forhindre ustabil gas flow. (2) Tjek systemet for lækage ved tilsluttet måleinstrumenter, samlinger og andet tilsluttet udstyr. Derefter øg trykket i systemet indtil arbejdstrykket er opnået. x Før reparation tjek altid at procesledningen ikke står under tryk. Hvis der er brug for at udskifte defekte dele må kun kvalificeret personale udføre arbejdet og af sikkerhedsmæssige årsager må der kun anvendes originale Brooks reservedele. Det er ikke tilladt at anvende reservedele eller udføre arbejde der på nogen måde kan ændre produktet fra dens oprindelige specifikationer. Manglende overholdelse af de foreskrevne procedurer kan resultere i brænd, og fare for elektrisk stød eller kortslutning. x Af sikkerhedsmæssige årsager sørg for at alle sikkerhedsforanstaltninger er overholdt. Eksempelvis at alle afskærmninger eller anden form for installationsbeskyttelse er lukket eller installeret ved normal drift. Advarsel.: Ved brug af udstyr som anvendes til væske skal det sikres at indgangsventilen og udgangsventilen ikke bliver lukket på samme tid i forbindelse med aftapning. Såfremt dette ikke overholdes, er der risiko for at væsken på grund af varmeudvikling ekspanderer og dette kan forårsage skade på udstyr og personer. Det Europæiske direktiv for trykudstyr (PED) På alt udstyr hvis indgangstryk er større end 0,5bar (g) og større end 25 mm eller en tomme, gælder det europæiske direktiv for trykapparater. Manualens afsnit ”tekniske data” indeholder anvisninger om PED direktivet. x I manualen angives måleinstrumenter der er tilpasset direktivet 97/23/EK EU. x Alle Brooks gennemstrømningsmålere tilhører væskegruppen nr. 1. x Alle målinstrumenter som er større end 25 mm eller en tomme beskrives i direktivet PED´s kategorier I, II eller III. x Alle målinstrumenter som er på 25 mm eller en tomme, eller mindre, beskrives i Sound Engineering Practice (SEP). Det europæiske direktiv for elektromagnetisk kompatibilitet (EMC) Alle Brooks instrumenter (elektrisk/elektronisk) som har CE markering er godkendt og testet ifølge om elektromagnetiske kompatibilitets forskrifter (EMC direktiv 2004/108/EC). OBS: Man skal være opmærksom på hvilken type kabler der bruges til CE mærket udstyr.. Om kvalitet af signalkabler, kabeltilslutninger og koblinger: Brooks tilbyder kabler af højest kvalitet, som er tilpasset CEE kvalificeringens forskrifter. Hvis man vælger at bruge egne kabler, skal man vælge et kabel som har den nødvendige afskærmning for at sikre 100 % mod udefra kommende støj. Tilslutningerne ”D” eller rundformede tilslutninger skal være afskærmet med skal af metal. Stikket skal være afskærmet på alle sider. Al afskærmning skal jordes.. Card Edge tilslutninger er ifølge standarden ikke metalliske.. De anvendte kabler og stik skal være 100 % afskærmet for at opfylde CE kravene.. De skal ligeledes jordes. For stik konfigurationen se vedlagte brugsvejledning. Elektrostatisk afladning (ESD) OBS.: Udstyret indeholder tilbehør som kan skades ved elektrostatisk elektricitet. Alle forskrifter skal overholdes ved kontakt med alle elektriske komponenter både under drift og vedligeholdelse.. Behandlingsproceduren: 1. Sluk for al strømtilførsel til udstyret. 2. Personer som skal i kontakt med udstyret skal være jordet eller bære anden form for elektrisk beskyttende udstyr. Manglende overholdelse af dette kan medføre skader på alle elektriske komponenter. 3. Alle elektriske komponenter skal opbevares eller transporteres i deres originale indpakning for at sikre komponenter mod statiske elektriske skader. Emballagen må ikke åbnes før komponenten skal installeres i udstyret. Ved afslutning af vedligeholdelse/reparation af udstyret, skal udstyret installeres med det samme eller pakkes forsvarligt hvis det skal på lager eller transporteres. Bemærkninger: Dette udstyr er ikke unik i den hensigt, at det indeholder for elektrostatisk afladning (ESD) sensitive reservedel. I de fleste elektronisk udstyr findes der metaloxyd teknologiske reservedel (NMOS, SMOS m.m.). Erfaringerne viser at selv den mindste statiske elektricitet kan skade, eller ødelægge disse instrumenter. Selv en fungerende elektrisk del kan have levetiden markant reduceret på grund af statisk elektricitet.. A-3 Section A - Essential Instructions Installation and Operation Manual Flow Controllers for Gas and Liquid Service X-VA-FC-eng Part Number: 541B045AAG December, 2015 Dutch Essentiële instructies Leeszevoordatuverdergaat! Brooks Instrument ontwerpt, produceert en test haar producten zodanig dat ze voldoen aan vele nationale en internationale normen. Deze producten moeten correct worden geïnstalleerd, bediend en onderhouden zodat ze binnen hun normale specificaties blijven werken. De volgende instructies moeten worden toegevoegd aan en geïntegreerd in uw veiligheidsprogramma als u producten van Brooks Instrument installeert, bedient en onderhoudt. • Om de juiste prestaties te kunnen garanderen mag alleen gekwalificeerd personeel het product installeren, bedienen, updaten, programmeren en onderhouden. • Lees alle instructies voordat u het product gaat installeren, bedienen en onderhouden. Als dit niet de juiste handleiding is, kijk dan op de achterzijde voor contactinformatie van uw vertegenwoordiger. Bewaar deze handleiding voor later. WAARSCHUWING: gebruik dit instrument niet als niet is voldaan aan de specificaties in de handleiding. Het niet naleven van deze waarschuwing kan ernstig letsel en/of schade aan de apparatuur tot gevolg hebben. • • • Als u één of meer instructies niet begrijpt, vraag dan om uitleg aan uw vertegenwoordiger van Brooks Instrument. Neem alle waarschuwingen, voorschriften en instructies in acht die op het product zijn aangebracht of bij het product zijn geleverd. Installeer uw apparatuur volgens de instructies in de bijgeleverde handleiding en in overeenstemming met de geldende lokale en nationale voorschriften. Sluit alle producten aan op de juiste elektrische voedings- en drukbronnen. • Bediening: (1) Laat het systeem langzaam volstromen. Open de procesafsluiters langzaam om drukstoten te voorkomen. (2) Controleer op lekkages rondom de inlaat- en uitlaataansluitingen van de stromingsmeter. Als er geen lekkages zijn, kan het systeem op de bedrijfsdruk worden gebracht. • Zorg ervoor dat de procesleiding drukvrij is gemaakt voordat u servicewerkzaamheden gaat uitvoeren. Als vervangingsonderdelen nodig zijn, zorg er dan voor dat gekwalificeerd personeel de door Brooks Instrument gespecificeerde vervangingsonderdelen gebruikt. Niet goedgekeurde onderdelen en procedures kunnen de prestaties van het product en de veilige werking van uw proces in gevaar brengen. Niet goedgekeurde vervangingsonderdelen kunnen brand, elektrische schokken of een onjuiste werking tot gevolg hebben. • Zorg ervoor dat alle deksels van de apparatuur gesloten zijn en de afdekkingen gemonteerd zijn om elektrische schokken en lichamelijk letsel te voorkomen, behalve als gekwalificeerd personeel de onderhoudswerkzaamheden uitvoert. WAARSCHUWING: bij vloeistofstroomapparaten waarvan de inlaat- en uitlaatkleppen om welke reden dan ook gesloten zijn, moet de vloeistof volledig worden afgetapt. Als dat wordt nagelaten, kan dit leiden tot thermische expansie van de vloeistof waardoor het apparaat kan barsten en lichamelijk letsel kan veroorzaken. PED-richtlijn (Pressure Equipment Directive) Alle drukapparatuur met een interne druk van meer dan 0,5 barg en een diameter van meer dan 25 mm valt onder de PED-richtlijn. x In het hoofdstuk Specificaties van deze handleiding staan aanwijzingen die verband houden met de PED-richtlijn. x De meters die in deze handleiding worden beschreven, voldoen aan de Europese richtlijn 97/23/EG. x Alle stromingsmeters van Brooks Instrument vallen in groep 1. x Meters met een diameter van meer dan 25 mm voldoen aan de categorieën I, II of III van de PED-richtlijn. x Meters met een diameter van 25 mm of kleiner voldoen aan de regels van goed vakmanschap. Elektromagnetische compatibiliteit (EMC) De elektronische apparatuur van Brooks Instrument met de CE-markering is succesvol getest in overeenstemming met de EMC-voorschriften (richtlijn EMC 2004/108/EC). De keuze van de signaalkabel voor gebruik in combinatie met apparatuur met CE-markering verdient speciale aandacht. Kwaliteit van de signaalkabel, kabelafdichtingen en stekkers: Brooks Instrument levert hoogwaardige kabels die voldoen aan de specificaties voor de CE-markering. Als u zelf voor signaalkabel zorgt, moet u altijd een volledig afgeschermde kabel gebruiken. Stekkers van het type “D” of ronde stekkers moeten zijn voorzien van een metalen afscherming. Indien nodig moeten metalen kabelafdichtingen worden gebruikt waarvan de afscherming voor het klemmen van de kabel kan worden gebruikt. Het kabelscherm moet met het metalen omhulsel of de metalen afdichting worden verbonden en aan beide uiteinden rondom volledig worden afgeschermd. De afscherming moet aan de aardpotentiaal worden aangesloten. Card Edge Connectors zijn standaard niet van metaal. De gebruikte kabels moeten volledig zijn afgeschermd om te voldoen aan de CE-markering. De afscherming moet aan de aardpotentiaal worden aangesloten. Voor de pinconfiguratie: Raadpleeg de bijgevoegde handleiding. Elektrostatische ontlading VOORZICHTIG: Dit instrument bevat elektronische componenten die gevoelig zijn voor statische elektriciteit. Neem de juiste procedures in acht bij het verwijderen en installeren of bij andere werkzaamheden aan de interne printplaten of apparaten. Procedure: 1. Schakel de voeding van de eenheid uit. 2. Het personeel moet zich met een polsbandje of ander veilig en geschikt hulpmiddel aarden voordat een printplaat of ander intern apparaat mag worden geïnstalleerd, verwijderd of aangepast. 3. Printplaten moeten in een geleidende verpakking worden vervoerd. De platen mogen pas vlak voor de eigenlijke installatie uit de beschermende verpakking worden gehaald. Verwijderde printplaten moeten onmiddellijk in de beschermende verpakking worden geplaatst om te worden getransporteerd, opgeslagen of teruggestuurd naar de fabriek. Opmerkingen Dit instrument is niet uniek als het gaat om componenten die gevoelig zijn voor elektrostatische ontlading. De meeste moderne elektronische apparaten bevatten componenten die gebruik maken van de metaaloxidetechnologie (NMOS, SMOS, enz.). Uit ervaring blijkt dat zelfs kleine hoeveelheden statische elektriciteit deze apparaten al dan niet onherstelbaar kunnen beschadigen. Beschadigde componenten, zelfs als ze goed lijken te functioneren, raken eerder defect. A-4 Section A - Essential Instructions Installation and Operation Manual X-VA-FC-eng Part Number: 541B045AAG December, 2015 Flow Controllers for Gas and Liquid Service Estonian Olulised juhised Enne kasutamist lugege hoolikalt läbi! Brooks Instrument konstrueerib, valmistab ja katsetab oma tooteid selliselt, et need vastaksid paljude erinevate riiklike ja rahvusvaheliste standardite nõuetele. Ainult nõuetekohane paigaldamine, kasutamine ja hooldamine tagab toodete katkematu talitluse tavaspetsifikatsiooni raames. Brooks Instrument'i toodete paigaldamisel, kasutamisel ja hooldamisel tuleb täita alljärgnevaid juhiseid ja integreerida need asjakohasesse ohutusprogrammi. x Nõuetekohase talitluse tagamiseks tohib toodet paigaldada, kasutada, täiustada, programmeerida ja hooldada ainult kvalifitseeritud personal. x Enne toote paigaldamist, kasutamist ja hooldamist lugege kõik kasutusjuhised hoolikalt läbi. Kui käesolev kasutusjuhend ei vasta teie tootele, pöörduge kohaliku edasimüüja poole, kelle kontaktandmed leiate kasutusjuhendi tagakaanelt. Hoidke see kasutusjuhend edaspidiseks alles. HOIATUS: ärge kasutage seda instrumenti väljaspool kasutusjuhendis spetsifitseeritud piirväärtusi. Selle hoiatuse eiramine võib põhjustada tõsiseid kehavigastusi ja/või kahjustada seadet. x Kui te saa mõne juhise mõttest aru, pöörduge selgituste saamiseks kohaliku Brooks Instrument’i edasimüüja poole. x Järgige kõiki hoiatusi, tähelepanule manitsusi ja juhiseid, mis on tootele peale kantud või tootega kaasa antud. x Seadme paigaldamisel järgige vastavas kasutusjuhendis toodud paigaldusjuhiseid ning asjakohaseid kohalikke ja riiklikke eeskirju. Ühendage tooted nõuetekohaste toite- ja surveallikatega. x Talitlus: (1) Avage aeglaselt vool süsteemi. Vooluimpulsside vältimiseks avage tööventiilid aeglaselt. (2) Kontrollige, et voolukulumõõturi sisend- või väljundühenduste ümber ei ole lekkeid. Kui lekkeid ei ole, laske süsteemil saavutada töösurve. x Enne seadme hooldamist veenduge, et kogu süsteem on surve alt vabastatud. Varuosasid tohib vahetada ainult kvalifitseeritud personal, kasutades selleks Brooks Instrument’i poolt heakskiidetud varuosi. Mitteoriginaalvaruosade kasutamine ja ebapädev toimingute tegemine võivad kahjustada toote tööomadusi ja põhjustada riski tootmistegevuse ohutuse tagamisel. Originaalvaruosadele sarnaste osade kasutamine võib põhjustada tule- või elektrilöögiohtu või seadme väärtalitlust. x Elektrilöögi- ja vigastuseohu vältimiseks peavad seadme luugid olema alati suletud ja kaitsekatted oma kohal, va seadme hooldamisel kvalifitseeritud isikute poolt. HOIATUS: voolava vedelikuga seadmete kasutamisel – kui seadmega külgnevad sisend- ja väljundklapid on vaja mingil põhjusel sulgeda, tuleb seadmed vedelikust täiesti tühjaks lasta. Vastasel korral võib vedelik soojuse mõjul paisuda niivõrd, et seade puruneb. See võib põhjustada tõsiseid kehavigastusi. Euroopa surveseadmete direktiiv (PED) Euroopa surveseadmete direktiiv kohaldub kõikidele surveseadmetele, mille sisesurve on üle 0,5 baari (g) ja läbimõõt üle 25 mm või 1 tolli. x Käesoleva kasutusjuhendi spetsifikatsiooniosa sisaldab surveseadmete direktiiviga seonduvaid juhiseid. x Käesolevas kasutusjuhendis kirjeldatud mõõturid vastavad EN direktiivi 97/23/EÜ nõuetele. x Brooks Instrument’i voolukulumõõturid kuuluvad vedelike 1. gruppi. x Mõõturid läbimõõduga üle 25 mm või 1 tolli vastavad surveseadmete direktiivi kategooriale I, II või III. x Mõõturitele läbimõõduga alla 25 mm või 1 tolli kohaldatakse häid inseneritavasid. Euroopa elektromagnetilise ühilduvuse direktiiv (EMÜ) Brooks Instrument’i (elektrilised/elektroonilised) seadmed, millele on omistatud CE-tähis, on edukalt läbinud asjakohased katsed ja vastavad elektromagnetilise ühilduvuse nõuetele (EMÜ direktiiv 2004/108/EC). Kuid signaalkaabli valimisel on vaja pöörata suurt tähelepanu CE-tähisega seadmetele. Signaalkaabli, läbiviigutihendite ja konnektorite kvaliteet Brooks Instrument turustab kõrgekvaliteedilisi kaableid, mis vastavad CE-sertifikaadi nõuetele. Olemasoleva kaabli kasutamisel jälgige, et kaabel oleks täielikult ümbritsetud varjestusega. „D” või „Ring“-tüüpi konnektorid peavad olema varustatud metallvarjestusega. Kus kohaldatav, tuleb kasutada metallist läbiviike, mis tagavad kaabli varjestuse ühenduse. Kaabli varjestus ühendatakse metallkesta või läbiviigutihendiga ja on mõlemast otsast kaitstud 360° ulatuses. Varjestus peab olema maandatud. Mikroskeemide servaühendused on üldjuhul mittemetallist. Vastavuse tagamiseks CE-sertifikaadi nõuetele peavad kasutatud kaablid olema 100% varjestatud. Varjestus peab olema maandatud. Klemmide konfigureerimine: vt komplekti kuuluvat kasutusjuhendit. Elektrostaatiline laeng TÄHELEPANU: seade sisaldab staatilise elektri suhtes tundlikke elektroonikakomponente. Seadmesse paigaldatud trükkplaatide eemaldamisel ja paigaldamisel, samuti trükkplaadi või seadmega muude toimingute teostamisel järgige nõuetekohase käsitsemise juhiseid. Käsitsemisjuhised 1. Lahutage seade toiteallikast. 2. Enne trükkplaadi või mõne muu siseelemendi paigaldamist, eemaldamist või konfigureerimist peab personal olema maandatud läbi randmepaela või mõne muu sobiva vahendi. 3. Trükkplaate transporditakse voolujuhtivas konteineris. Võtke trükkplaat kaitsvast konteinerist välja vahetult enne selle paigaldamist. Seadmest eemaldatud trükkplaadid tuleb viivitamatult asetada kaitsvasse konteinerisse kas siis edasiseks transportimiseks, hoiustamiseks või tehasesse tagasisaatmiseks. Kommentaarid See seade ei ole ainus, mis sisaldab staatilise elektri suhtes tundlikke elemente. Enamik kaasaegsetest elektroonikaseadmetest sisaldavad komponente, mille valmistamiseks on kasutatud metalloksiidtehnoloogiat (NMOS, SMOS jne). Kogemused näitavad, et isegi väike kogus staatilist elektrit võib neid seadmeid kahjustada või isegi hävitada. Kuigi võib näida, et kahjustatud komponendid töötavad nõuetekohaselt, hakkavad talitlushäired ilmnema juba varakult. A-5 Section A - Essential Instructions Installation and Operation Manual Flow Controllers for Gas and Liquid Service X-VA-FC-eng Part Number: 541B045AAG December, 2015 Finnish Perusohjeet Lue ensin ohjeet huolellisesti! Brooks Instrument suunnittelee, valmistaa ja testaa laitteensa vastaamaan useimpien kotimaisten ja kansainvälisten standardien vaatimuksia. Tuotteet tulee asentaa, käyttää ja huoltaa käyttöohjeiden mukaan jotta niiden toimivuus taataan. Brooks Instrumentin laitteiden asennuksessa, käytössä ja huollossa on noudatettava soveltuvia määräyksiä ja ohjeita, lisäksi mainitut ohjeet on huomioitava työsuojelun ohjeistuksessa. x x x x x x Oikean toiminnan varmistamiseksi vain valtuutettu huoltohenkilö saa asentaa, käynnistää, päivittää, ohjelmoida ja huoltaa laitteita. Lue kaikki käyttöohjeet koskien tuotteen asennusta, käyttöä ja huoltoa. Jos käyttöohje on puutteellinen, lisätietoja saa paikalliselta jälleenmyyjältä. Yhteystiedot löytyvät oppaan kansilehdestä. Säilytä ohjeet. VAROITUS!: Käyttöohjeessa ilmoitettujen standardien mukaisia ohjeita ja raja-arvoja ei saa ylittää. Rajoitusten laiminlyönti voi aiheuttaa tuotteen rikkoutumisen ja/tai vakavan henkilövahingon vaaran. Jos ohjeissa on epäselvyyttä, ota yhteyttä Brooks Instrumentin edustajaan ongelman selvittämiseksi. Noudata kaikkia laitteessa olevia tai siihen liittyviä ohjeita, määräyksia ja varoituksia. Laittteen asennuksessa on noudatettava erityisiä asennusohjeita sekä voimassa olevia paikallisia ja kansainvälisiä määräyksiä. Laitteet saa yhdistää vain soveltuvaan sähkö- ja paineverkkoon. Asennusohjeita: (1) Päästä virtaus hitaasti järjestelmään. Avaa venttiilit hitaasti, jotta virtaus pysyy tasaisena. (2) Tarkista, ettei virtausmittarin sisään- ja ulosmenon vieressä ole vuotoa. Jos järjestelmässä ei ole vuotoa, aseta oikea käyttöpaine. Tarkista, että laitteeseen menevä paine on katkaistu ennen laitteen korjaamista välttääksesi äkillisen painepäästön aiheuttaman loukkaantumisriskin. Mahdollisten varaosien tulee olla Brooks Instrumentin hyväksymiä. Vain valtuutettu huoltohenkilö saa asentaa varaosat. Ei-hyväksyttyjen varaosien käyttö voi vahingoittaa tuotteen toimintaa ja aiheuttaa turvallisuusriskin. Samoin eihyväksyttyjen varaosien käyttö voi aiheuttaa tulipalon, sähköiskun tai virhetoiminnan riskin. Varmista että kaikki kaikki laitteen ovet/luukut ovat suljettuina ja tarkista että suojakannet ovat paikoillaan estääksesi mahdollisen sähköisku- ja loukkaantumisvaaran. VAROITUS!: Jos järjestelmässä virtaa neste ja laitteen sisään- ja ulosmenoventtiilit pitää sulkea, laite on ensin tyhjennettävä kokonaan. Tyhjentämisen laiminlyönti aiheuttaa nesteen lämpölaajenemista, joka saattaa johtaa laitteen rikkoutumiseen ja henkilövahingon vaaraan. Eurooppalainen painelaitedirektiivi (PED) Painelaitteet, joidenpaine on suurempi kuin 0,5 bar ja joiden koko on suurempi kuin 25 mm tai 1 tuuma , kuuluvat eurooppalaiseen painelaitedirektiiviin (PED). x PED direktiiviä koskevat määräykset löytyvät käyttöoppaan ’’Tekniset tiedot” -luvusta. x Käyttöoppaassa kuvatut mittarit ovat 97/23/EC EU-direktiivin mukaisia. x Kaikki Brooks Instrumentin virtausmittarit kuuluvat virtausryhmään 1. Laitteet jotka ovat suurempia, kuin 25 mm tai 1 tuuma, ovat PED I, II, III kategorien mukaisia. x Mittarit joiden koko on alle 25 mm tai 1 tuuma ovat hyvän konepajakäytännön (SEP) mukaisia. Eurooppalainen direktiivi sähkömagneettisesta yhteensopivuudesta (EMC) Brooks Instrumentin CE-merkin saaneet (sähkö/sähköiset) laitteet täyttävät EMC direktiivin vaatimukset ja testit sähkömagneettisesta yhteensopivuudesta (2004/108/EC EMC direktiivi). Erityistä huomioita on kiinnitettävä CE-merkittyjen laitteiden käytössä olevien kaapelien valintaan. Kaapelien, kiinnikkeiden ja liittimien laatu: Brooks Insturmentin kaapelit ovat korkealaatuisia ja täyttävät CE-merkintä direktiivin vaatimukset. Muun valmistajan kaapelia käytettäessä on käytettävä 100% suojattua kaapelia. Liittimien tulee olla häiriösuojattua tyyppiä. Tarvittaessa käytetään metallisia kiinnikkeitä kaapelin suojuksen kiinnittämiseen. Kaapelin o suojakuoren pitää olla yhdistettynä metallisuojukseen tai laippaan ja sen pitää olla molemmista päistä suojattuna 360 . Suojaus päättyy maadoitukseen. Standardin mukaan korttien liittimet eivät ole metallisia. Käytettyjen kaapelien suojaus on oltava 100%, jotta se täyttäisi CEmerkinnän direktiivin vaatimukset. Suojaus päättyy maadoitukseen. Napojen järjestys: Katso liitteenä oleva käyttöopas. Elektrostaattinen purkaus (ESD) VAROITUS!: Tuote sisältää elektroniikkakomponentteja jotka voivat vahingoittua staattisesta sähköstä. Sisäisten piirilevyjen purkamisessa,asennuksessa ja käsittelyssä tulee noudattaa kaikkia määräyksiä ja ohjeita. Asennusohjeet: 1. Järjestelmän sähköt katkaistaan. 2. Laitteen kanssa työskentelevä henkilö on suojattava sähköiskuilta rannehihnalla tai muulla suojavarustuksella ennen piirilevyn tai muun sisäosan asennusta, poistamista tai korjaamista. 3. Piirilevyt kuljetetaan konduktiivisessa pakkauksessa. Piirilevyt puretaan paketista juuri ennen asennusta. Poistettu piirilevy on heti pakattava soveltuvaan suojapakkaukseen kuljettamista, varastoimista tai palautusta varten. Huomautukset: Tuotteen herkkyys elektrostaattiselle purkaukselle (ESD) ei ole epätavallista. Suurin osa elektroniikkatuotteista sisältää komponentteja jotka hyödyntävät metallioksiditekniikkaa (NMOS, SMOS jne.) Kokemusten mukaan pienikin elektrostaattinen purkaus voi aiheuttaa laitteiden virhetoiminnan tai vahingoittumisen. Vahingoittuneet komponentit saattavat aiheuttaa laitteen ennenaikaisen rikkoutumisen vaikka laite näyttäisi toimivan normaalisti. A-6 Section A - Essential Instructions Installation and Operation Manual X-VA-FC-eng Part Number: 541B045AAG December, 2015 Flow Controllers for Gas and Liquid Service French Instructions essentielles A lire avant de commencer ! Brooks Instrument conçoit, fabrique et teste ses produits pour répondre à de nombreuses normes nationales et internationales. Ces produits doivent être correctement installés, utilisés et entretenus pour pouvoir fonctionner dans le cadre de leurs spécifications normales. Les instructions qui suivent doivent être respectées et intégrées à votre programme de sécurité lors de l’installation, l’utilisation et l’entretien des produits Brooks Instrument. • Afin d’assurer un fonctionnement correct, faites appel à du personnel qualifié pour l’installation, l’utilisation, la mise à jour, la programmation et l’entretien du produit. • Lisez toutes les instructions avant l’installation, l’utilisation et l’entretien du produit. Si le présent manuel d’utilisation n’est pas le bon, consultez la dernière page de la couverture pour connaître le point de vente le plus proche. Conservez ce manuel d’utilisation pour pouvoir vous y reporter par la suite. AVERTISSEMENT : n’utilisez pas cet instrument au-delà des spécifications énumérées dans le manuel d’utilisation. Le non-respect de cet avertissement peut entraîner de graves blessures et / ou endommager l’équipement. • Si vous ne comprenez pas l’une des instructions, prenez contact avec un représentant de Brooks Instrument pour obtenir des explications. • Tenez compte de tous les avertissements, précautions et instructions marquées sur le produit et fournies avec celui-ci. • Installez votre équipement de la façon indiquée dans les instructions d’installation du manuel d’utilisation et conformément à la législation en vigueur au niveau local et national. Branchez tous les produits aux sources d’électricité et de pression agréées. • Utilisation : (1) Faites lentement entrer le débit dans le système. Ouvrez progressivement les vannes de procédé pour éviter des pics de débits. (2) Vérifiez qu’il n’y a pas de fuite au niveau des branchements d’entrée et de sortie du débitmètre. S’il n’y a pas de fuite, amenez le système à sa pression d’utilisation. • Avant de procéder à l’entretien, assurez-vous que la conduite de procédé n’est plus sous pression. Lorsqu’il faut remplacer une pièce, assurez-vous que les pièces de rechange sont celles indiquées par Brooks Instrument et que des personnes qualifiées effectuent le remplacement. Les pièces et procédures non autorisées peuvent porter atteinte au fonctionnement du produit et mettre en péril la sécurité de votre procédé. Les remplacements par des pièces d’apparence similaire peuvent entraîner des incendies, des risques électriques ou un mauvais fonctionnement. • Vérifiez que toutes les trappes de l’équipement sont fermées et que les couvercles de protection sont en place pour éviter les chocs électriques et les blessures, sauf lorsque l’entretien est réalisé par des personnes qualifiées. AVERTISSEMENT : dans le cas d’appareils à écoulement liquide, si les vannes d’entrée et de sortie adjacentes aux appareils doivent être fermées pour une raison quelconque, les appareils doivent être complètement vidangés. Si cela n’est pas fait, une éventuelle dilatation thermique du fluide peut casser l’appareil et provoquer des blessures. Directive européenne « équipements sous pression » (PED) Tous les équipements sous pression dont la pression interne est supérieure à 0,5 bar (pression relative) et dont la taille dépasse 25 mm ou un pouce entrent dans le cadre de la directive PED. • La section « Spécifications » de ce manuel contient les instructions relatives à la directive PED. • Les appareils de mesure de ce manuel sont conformes à la directive EN 97/23/EC. • Tous les débitmètres Brooks Instrument fonctionnent avec des fluides de groupe 1. • Les appareils de mesure d’une taille supérieure à 25 mm ou un pouce entrent dans la catégorie PED I, II ou III. • Les appareils de mesure d’une taille inférieure ou égale à 25 mm ou un pouce relèvent des « bonnes pratiques d’ingénierie » (SEP). Compatibilité électromagnétique européenne (CEM) L’équipement Brooks Instrument (électrique / électronique) portant le marquage CE répond à la réglementation en matière de compatibilité électromagnétique (directive CEM 2004/108/EC). Il faut cependant prêter une grande attention au choix du câble d’interconnexion à utiliser avec l’équipement marqué CE. Qualité du câble d’interconnexion, des presse-étoupes et connecteurs : Brooks Instrument fournit un ou des câbles de qualité supérieure qui répondent aux spécifications exigées pour la certification CE. Si vous utilisez votre propre câble d’interconnexion, ce câble doit être protégé par un blindage intégral. Les connecteurs rectangulaires ou circulaires utilisés doivent avoir un blindage métallique. S’il y a lieu, des presse-étoupes métalliques doivent faire office de serre-écran de câble. L’écran du câble doit être raccordé à l’enveloppe métallique ou au presse-étoupe et blindé aux deux extrémités sur 360 degrés. Le blindage doit s’achever sur une prise de terre. Les connecteurs de carte standards sont non métalliques. Les câbles utilisés doivent être protégés par un blindage intégral pour se conformer à la certification CE. Le blindage doit s’achever sur une prise de terre. En ce qui concerne la configuration des broches, veuillez vous reporter au manuel d’utilisation joint. ESD (décharge électrostatique) ATTENTION : cet instrument contient des composants électroniques sensibles à l’électricité statique. Des procédures de manipulation adéquates doivent être respectées pendant le retrait, l’installation ou la manipulation des cartes de circuits imprimés ou des dispositifs internes. Procédure de manipulation : 1. L’alimentation électrique de l’appareil doit être coupée. 2. Le personnel doit être mis à la terre, au moyen d’une bande de poignet ou d’un autre moyen sûr et adéquat, avant l’installation, le retrait ou le réglage de toutes les cartes de circuits imprimés ou autres dispositifs internes. 3. Les cartes de circuits imprimés doivent être transportées dans un récipient conducteur. Les cartes ne doivent enlevées de cette enveloppe protectrice qu’au dernier moment, juste avant l’installation. Les cartes retirées doivent être immédiatement placées dans un récipient de protection pour le transport, le stockage ou le retour à l’usine. Observations Brooks Instrument n’est pas le seul à proposer des produits comportant des composants sensibles aux décharges électrostatiques. La plupart des produits électroniques modernes contiennent des composants qui utilisent des technologies à oxydes métalliques (NMOS, SMOS, etc.). L’expérience démontre que d’infimes quantités d’électricité statique suffisent à endommager ou détruire ces appareils. Les composants endommagés, même s’ils semblent fonctionner correctement, tombent rapidement en panne. A-7 Section A - Essential Instructions Installation and Operation Manual Flow Controllers for Gas and Liquid Service X-VA-FC-eng Part Number: 541B045AAG December, 2015 German Wichtige Anweisungen Bitte zuerst lesen! Brooks Instrument entwickelt, produziert und testet seine Produkte derart, dass sie viele nationale und internationale Standards erfüllen. Nur bei korrektem Einbau sowie richtiger Bedienung und Wartung dieser Produkte ist ein Betrieb unter Einhaltung der Standardvorgaben sichergestellt. Die folgenden Anweisungen müssen eingehalten werden und in Ihr Sicherheitsprogramm integriert werden, wenn Sie Brooks Produkte installieren, bedienen und warten. • Um die entsprechende Leistung zu gewährleisten, setzen Sie qualifiziertes Personal für die Installation, den Betrieb, die Aktualisierung, Programmierung und Wartung des Produkts ein. • Lesen Sie alle Anweisungen, bevor Sie das Produkt installieren, in Betrieb nehmen und warten. Falls es sich bei diesem Handbuch nicht um das richtige Handbuch handelt, schauen Sie bitte auf der Rückseite nach den Kontaktdaten Ihres Vertriebsbüros vor Ort. Bewahren Sie dieses Handbuch auf, falls Sie später etwas nachschauen möchten. WARNUNG: Dieses Gerät nicht außerhalb der in Bedienungsanleitung und Handbuch angegebenen Grenzen betreiben. Wird diese Warnung nicht beachtet, kann dies zu schweren Personenschäden bzw. Schäden des Gerätes führen. • Falls Sie Anweisungen nicht verstehen, wenden Sie sich zur Klärung an Ihren Brooks Instrument Vertreter. • Befolgen Sie alle Warnhinweise und Anweisungen, die auf dem Produkt markiert sind oder zusammen mit diesem geliefert werden. • Installieren Sie Ihr Gerät, wie in den Installationsanweisungen des entsprechenden Handbuchs angegeben und gemäß der gültigen regionalen und nationalen Gesetze. Schließen Sie alle Produkte an eine geeignete Strom- und Druckluftversorgung an. • Bedienung: (1) Langsam den Zufluss zum System starten. Die Ventile langsam öffnen, um einen sprunghaften Anstieg der Durchflussmenge zu verhindern. (2) Bereich der Anschlüsse (Zufluss und Ausfluss) des Durchflussmessers auf Undichtigkeiten überprüfen. Wenn das System dicht ist, auf Betriebsdruck hochfahren. • Sicherstellen, dass der Leitungsdruck vor Wartungsarbeiten heruntergefahren wird. Wenn Ersatzteile benötigt werden, stellen Sie sicher, dass qualifizierte Personen Ersatzteile verwenden, die von Brooks Instrument vorgegeben sind. Nicht genehmigte Teile und Verfahren können die Leistungsfähigkeit des Produkts beeinträchtigen und den sicheren Betrieb Ihres Prozesses gefährden. Ähnlich aussehende Austauschteile können zu Bränden, elektrischen Gefahren oder nicht sachgerechtem Betrieb führen. • Stellen Sie sicher, dass alle Türen der Anlage geschlossen sind und dass alle Schutzabdeckungen angebracht sind, um Stromschläge und Personenschäden zu vermeiden, es sei denn die Wartungsaufgaben werden von qualifizierten Personen durchgeführt. WARNUNG: Werden die Ein- und Auslassventile neben Durchflussmessgeräten aus irgendwelchen Gründen geschlossen, so müssen die Geräte komplett entleert werden. Durchflussmessgeraete muessen vor dem Schliessen von Ein- und Auslassventilen komplett entleert werden, anderenfalls kann es zu einer thermischen Ausdehnung der Flüssigkeit und damit zum Bruch des Gerätes kommen; Personenschäden können die Folge sein. Europäische Druckgeräterichtlinie (PED) Alle Druckgeräte mit einem internen Druck von mehr als 0,5 bar (g) und einer Größe von mehr als 1in ( 1 in = 25,4 mm) unterliegen der Druckgeräterichtlinie. x Das Kapitel zu den technischen Daten in dieser Anleitung enthält wichtige Sicherheits- und Betriebsanweisungen in Bezug auf die Druckgeräterichtlinie. x Messgeräte, die in diesem Handbuch beschrieben sind, erfüllen die europäische Richtlinie 97/23/EG. x Alle Durchflussmesser von Brooks Instrument fallen unter die Fluidgruppe 1. x Messgeräte, die größer als 25 mm oder 1“ (inch) sind, erfüllen die Kategorien I, II oder III der Druckgeräterichtlinie (PED). x Messgeräte mit einer Größe von 25 mm oder 1“ (inch) oder kleiner sind Sound Engineering Practice (SEP). Europäische Verordnung zur elektromagnetischen Verträglichkeit (EMV) Geräte von Brooks Instrument (elektrischer und elektronischer Art) mit CE-Zeichen haben den Test auf Einhaltung der Verordnung zur elektromagnetischen Verträglichkeit (EMV Richtlinie 2004/108/EC) erfolgreich bestanden. Dennoch muss bei der Wahl des Signalkabels für das Gerät mit CE-Zeichen auf folgende Dinge geachtet werden. Qualität von Signalkabel, Kabeldurchführung und Anschlüsse: Brooks Instrument liefert qualitativ hochwertige Kabel, die den Anforderungen für eine CE-Zertifizierung entsprechen. Sollten Sie eigene Kabel einsetzen, so sollte das Kabel überall mit einer 100%-Abschirmung versehen sein. D- oder Rundstecker sollten eine Metallabschirmung aufweisen. Wenn möglich, müssen Kabeldurchführungen aus Metall mit Kabelschirmgeflechts-Klemmen verwendet werden. Der Kabelschirm sollte an die Metallhülle oder -durchführung angeschlossen werden und an beiden Enden rundherum (360 °) abgeschirmt werden. Die Abschirmung sollte geerdet werden. Randstecker auf Platinen sind standardmäßig nicht aus Metall. Die verwendeten Kabel müssen mit einer 100 % Abschirmung versehen werden, um die CEVorgaben zu erfüllen. Die Abschirmung sollte geerdet werden. Klemmenbelegung: Siehe beigefügtes Handbuch. ESD (Elektrostatische Entladung) ACHTUNG: Dieses Gerät enthält elektronische Komponenten, die durch elektrostatische Entladungen beschädigt werden können. Ordnungsgemäße Verfahrensanweisungen müssen während des Ausbaus, der Installation oder anderer Handhabung der eingebauten Platinen oder Geräte eingehalten werden. Verfahrensanweisung: 1. Trennen Sie das Gerät von der Stromversorgung. 2. Das Personal ist vor dem Einbau, Ausbau oder der Einstellung von Platinen oder anderen internen Komponenten durch ein entsprechendes Armband mit dem Erdpotential zu verbinden. 3. Platinen sind in speziellen Behältern mit Schutz gegen elektrostatische Spannungen zu transportieren oder zu lagern. Platinen dürfen erst kurz vor dem Einbau aus der Schutzhülle entfernt werden. Ausgebaute Platinen müssen umgehend in Schutzbehälter zum Transport, zur Lagerung oder Rücksendung an das Werk gelegt werden. Anmerkung Dieses Gerät ist wie viele andere elektronische Geräte auch mit Komponenten bestückt, die anfällig für elektrostatische Entladung sind. Die meisten modernen, elektronischen Geräte enthalten Komponenten, die die Metalloxidtechnologie (NMOS, SMOS etc.) verwenden. Die Erfahrung hat gezeigt, dass schon geringe Mengen elektrostatischer Energie ausreichen, um diese Geräte zu beschädigen oder zu zerstören. Beschädigte Teile fallen früh aus, obwohl sie funktionsfähig zu sein scheinen. A-8 Installation and Operation Manual X-VA-FC-eng Part Number: 541B045AAG December, 2015 Section A - Essential Instructions Flow Controllers for Gas and Liquid Service Greek ǺĮıȚțȑȢ ȠįȘȖȓİȢ ǻȚĮȕȐıIJİ ʌȡȚȞ ıȣȞİȤȓıİIJİ! Ǿ Brooks Instrument ıȤİįȚȐȗİȚ, ʌĮȡȐȖİȚ țĮȚ įȠțȚȝȐȗİȚ IJĮ ʌȡȠȧȩȞIJĮ IJȘȢ ıİ ıȣȝȝȩȡijȦıȘ ȝİ ʌȜȒșȠȢ İșȞȚțȫȞ țĮȚ įȚİșȞȫȞ ʌȡȠIJȪʌȦȞ. Ǿ ıȦıIJȒ İȖțĮIJȐıIJĮıȘ, ȤȡȒıȘ țĮȚ ıȣȞIJȒȡȘıȒ IJȠȣȢ ĮʌȠIJİȜİȓ ĮʌĮȡĮȓIJȘIJȘ ʌȡȠȨʌȩșİıȘ IJȘȢ ȜİȚIJȠȣȡȖȓĮȢ İȞIJȩȢ IJȦȞ țĮȞȠȞȚțȫȞ ȠȡȓȦȞ. ȅȚ ʌĮȡĮțȐIJȦ ȠįȘȖȓİȢ ʌȡȑʌİȚ ȞĮ IJȘȡȠȪȞIJĮȚ țĮȚ ʌȡȑʌİȚ ȞĮ İȞıȦȝĮIJȦșȠȪȞ ıIJȠ ʌȡȩȖȡĮȝȝĮ ĮıijȐȜİȚĮȢ IJȘȢ İȡȖĮıȓĮȢ ıĮȢ țĮIJȐ IJȘȞ İȖțĮIJȐıIJĮıȘ, ȤȡȒıȘ țĮȚ ıȣȞIJȒȡȘıȘ ʌȡȠȧȩȞIJȦȞ IJȘȢ Brooks Instrument. x īȚĮ ıȦıIJȩ ĮʌȠIJȑȜİıȝĮ Ș İȖțĮIJȐıIJĮıȘ, ȜİȚIJȠȣȡȖȓĮ, İȞȘȝȑȡȦıȘ, ʌȡȠȖȡĮȝȝĮIJȚıȝȩȢ țĮȚ ıȣȞIJȒȡȘıȘ ʌȡȑʌİȚ ȞĮ ȖȓȞİIJĮȚ Įʌȩ İȚįȚțİȣȝȑȞȠ ʌȡȠıȦʌȚțȩ. x ǻȚĮȕȐıIJİ ȩȜİȢ IJȚȢ ȠįȘȖȓİȢ ʌȡȚȞ İȖțĮIJĮıIJȒıİIJİ, ȜİȚIJȠȣȡȖȒıİIJİ țĮȚ ıȣȞIJȘȡȒıİIJİ IJȠ ʌȡȠȧȩȞ. ǼȐȞ IJȠ ʌĮȡȩȞ İȖȤİȚȡȓįȚȠ įİȞ İȓȞĮȚ IJȠ ıȦıIJȩ İȖȤİȚȡȓįȚȠ, ıȣȝȕȠȣȜİȣșİȓIJİ IJȠ ʌȓıȦ İȟȫijȣȜȜȠ ȖȚĮ IJĮ ıIJȠȚȤİȓĮ İʌȚțȠȚȞȦȞȓĮȢ IJȠȣ IJȠʌȚțȠȪ ĮȞIJȚʌȡȠıȫʌȠȣ. ĭȣȜȐȟIJİ IJȠ İȖȤİȚȡȓįȚȠ ĮȣIJȩ ȖȚĮ ȝİȜȜȠȞIJȚțȒ ĮȞĮijȠȡȐ. ȆȇȅǼǿǻȅȆȅǿǾȈǾ: ȂȘ ȜİȚIJȠȣȡȖİȓIJİ IJȘ ıȣıțİȣȒ ĮȣIJȒ țĮș’ ȣʌȑȡȕĮıȘ IJȦȞ ȠȡȓȦȞ ʌȠȣ ĮȞĮȖȡȐijȠȞIJĮȚ ıIJȠ ǼȖȤİȚȡȓįȚȠ ȅįȘȖȚȫȞ țĮȚ ȁİȚIJȠȣȡȖȓĮȢ. Ǿ ȝȘ ıȣȝȝȩȡijȦıȘ ȝİ IJȘȞ ʌȡȠİȚįȠʌȠȓȘıȘ ĮȣIJȒ ȝʌȠȡİȓ ȞĮ ȠįȘȖȒıİȚ ıİ ıȠȕĮȡȩ ʌȡȠıȦʌȚțȩ IJȡĮȣȝĮIJȚıȝȩ Ȓ/țĮȚ ȗȘȝȚȐ ıIJȠȞ İȟȠʌȜȚıȝȩ. x Ȉİ ʌİȡȓʌIJȦıȘ ȝȘ țĮIJĮȞȩȘıȘȢ țȐʌȠȚĮȢ Įʌȩ IJȚȢ ȠįȘȖȓİȢ ȗȘIJȒıIJİ įȚİȣțȡȚȞȓıİȚȢ Įʌȩ IJȠȞ IJȠʌȚțȩ ĮȞIJȚʌȡȩıȦʌȠ IJȘȢ Brooks Instrument. x ȉȘȡİȓIJİ ȩȜİȢ IJȚȢ ʌȡȠİȚįȠʌȠȚȒıİȚȢ, ʌȡȠijȣȜȐȟİȚȢ țĮȚ ȠįȘȖȓİȢ ʌȠȣ ĮȞĮȖȡȐijȠȞIJĮȚ Ȓ ıȣȞȠįİȪȠȣȞ IJȠ ʌȡȠȧȩȞ. x ǼȖțĮIJĮıIJȒıIJİ IJȘ ıȣıțİȣȒ ȩʌȦȢ ʌȡȠȕȜȑʌİIJĮȚ ıIJȚȢ ȠįȘȖȓİȢ İȖțĮIJȐıIJĮıȘȢ IJȠȣ ıȦıIJȠȪ İȖȤİȚȡȚįȓȠȣ ȠįȘȖȚȫȞ țĮȚ ıIJȚȢ țİȓȝİȞİȢ IJȠʌȚțȑȢ țĮȚ İșȞȚțȑȢ įȚĮIJȐȟİȚȢ. ȈȣȞįȑıIJİ IJĮ ʌȡȠȧȩȞIJĮ ıIJȚȢ İțȐıIJȠIJİ ıȦıIJȑȢ ʌĮȡȠȤȑȢ ȡİȪȝĮIJȠȢ țĮȚ ʌȓİıȘȢ. x ǻȚĮįȚțĮıȓĮ: (1) ǹijȒıIJİ ȞĮ ȟİțȚȞȒıİȚ ĮȡȖȐ Ș ȡȠȒ ıIJȠ ıȪıIJȘȝĮ. ǹȞȠȓȟIJİ ĮȡȖȐ IJȚȢ ȕĮȜȕȓįİȢ ȜİȚIJȠȣȡȖȓĮȢ ȖȚĮ ȞĮ ĮʌȠijȪȖİIJİ IJȚȢ ĮʌȩIJȠȝİȢ ĮȣȟȠȝİȚȫıİȚȢ ȡȠȒȢ. (2) ǼȜȑȖȟIJİ ȖȚĮ įȚĮȡȡȠȑȢ IJȚȢ ıȣȞįȑıİȚȢ İȚıȩįȠȣ țĮȚ İȟȩįȠȣ IJȠȣ ȡȠȩȝİIJȡȠȣ. ǹȞ įİȞ ȣʌȐȡȤȠȣȞ įȚĮȡȡȠȑȢ, ȖİȝȓıIJİ IJȠ ıȪıIJȘȝĮ ȝȑȤȡȚ Ș ʌȓİıȘ ȞĮ ijIJȐıİȚ IJȘȞ țĮȞȠȞȚțȒ ʌȓİıȘ İȡȖĮıȓĮȢ. x ȆȡȚȞ Įʌȩ IJȘ ıȣȞIJȒȡȘıȘ ȕİȕĮȚȦșİȓIJİ ȩIJȚ ȖȡĮȝȝȒ İȡȖĮıȓĮȢ ȑȤİȚ IJİșİȓ İțIJȩȢ ʌȚȑıİȦȢ. Ȉİ ʌİȡȓʌIJȦıȘ ĮȞIJȚțĮIJȐıIJĮıȘȢ ĮȞIJĮȜȜĮțIJȚțȫȞ ȕİȕĮȚȦșİȓIJİ ȩIJȚ IJȠ ʌȡȠıȦʌȚțȩ İȓȞĮȚ İȚįȚțİȣȝȑȞȠ țĮȚ ȤȡȘıȚȝȠʌȠȚİȓ ĮȞIJĮȜȜĮțIJȚțȐ ʌȠȣ ʌȡȠȕȜȑʌİȚ Ș Brooks Instrument. ȂȘ İȖțİțȡȚȝȑȞĮ ĮȞIJĮȜȜĮțIJȚțȐ țĮȚ İʌİȝȕȐıİȚȢ İȞįȑȤİIJĮȚ ȞĮ İʌȘȡİȐıȠȣȞ IJȚȢ İʌȚįȩıİȚȢ IJȠȣ ʌȡȠȧȩȞIJȠȢ țĮȚ ȞĮ ʌȡȠțĮȜȑıȠȣȞ țȓȞįȣȞȠ ȖȚĮ IJȘȞ ĮıijĮȜȒ ȜİȚIJȠȣȡȖȓĮ. ǹȞIJȚțĮIJĮıIJȐıİȚȢ ȝİ ijĮȚȞȠȝİȞȚțȐ ȩȝȠȚĮ ĮȞIJĮȜȜĮțIJȚțȐ İȞįȑȤİIJĮȚ ȞĮ ʌȡȠțĮȜȑıȠȣȞ ʌȣȡțĮȖȚȐ, țȓȞįȣȞȠ ȘȜİțIJȡȠʌȜȘȟȓĮȢ Ȓ ĮȞİʌĮȡțȒ ȜİȚIJȠȣȡȖȓĮ. x ǺİȕĮȚȦșİȓIJİ ȩIJȚ ȩȜĮ IJĮ ĮȞȠȓȖȝĮIJĮ IJȠȣ İȟȠʌȜȚıȝȠȪ İȓȞĮȚ țȜİȚıIJȐ țĮȚ IJĮ ʌȡȠıIJĮIJİȣIJȚțȐ țĮȜȪȝȝĮIJĮ İȓȞĮȚ ıIJȘ șȑıȘ IJȠȣȢ ʌȡȠțİȚȝȑȞȠȣ ȞĮ ĮʌȠijİȣȤșİȓ Ƞ țȓȞįȣȞȠȢ ȘȜİțIJȡȠʌȜȘȟȓĮȢ țĮȚ ʌȡȠıȦʌȚțȫȞ IJȡĮȣȝĮIJȚıȝȫȞ, İțIJȩȢ İȐȞ İțIJİȜȠȪȞIJĮȚ İȡȖĮıȓİȢ ıȣȞIJȒȡȘıȘȢ Įʌȩ İȚįȚțİȣȝȑȞȠ ʌȡȠıȦʌȚțȩ. ȆȇȅǼǿǻȅȆȅǿǾȈǾ: ȆȡȠțİȚȝȑȞȠȣ ȖȚĮ ıȣıțİȣȑȢ ȝİ ȡȠȒ ȡİȣıIJȠȪ, ȩIJĮȞ ȖȚĮ ȠʌȠȚȠȞįȒʌȠIJİ ȜȩȖȠ ʌȡȩțİȚIJĮȚ ȞĮ țȜİȓıȠȣȞ ȠȚ ȕĮȜȕȓįİȢ İȚıĮȖȦȖȒȢ țĮȚ İȟĮȖȦȖȒȢ țȠȞIJȐ ıIJȚȢ ıȣıțİȣȑȢ, ȠȚ ıȣıțİȣȑȢ ʌȡȑʌİȚ ȞĮ ĮʌȠıIJȡĮȖȖȚıIJȠȪȞ İȞIJİȜȫȢ. Ǿ ȝȘ ıȣȝȝȩȡijȦıȘ ȝʌȠȡİȓ ȞĮ ʌȡȠțĮȜȑıİȚ șİȡȝȚțȒ įȚĮıIJȠȜȒ IJȠȣ ȣȖȡȠȪ ʌȠȣ ʌİȡȚȑȤȠȣȞ, ȝİ ĮʌȠIJȑȜİıȝĮ ȞĮ ȡĮȖȓıİȚ Ș ıȣıțİȣȒ țĮȚ ȞĮ ʌȡȠțȜȘșȠȪȞ ʌȡȠıȦʌȚțȠȓ IJȡĮȣȝĮIJȚıȝȠȓ. ǼȣȡȦʌĮȧțȒ ȅįȘȖȓĮ ȖȚĮ IJȠȞ İȟȠʌȜȚıȝȩ ȣʌȩ ʌȓİıȘ (PED) ȀȐșİ İȟȠʌȜȚıȝȩȢ ȣʌȩ ʌȓİıȘ ȝİ İıȦIJİȡȚțȒ ʌȓİıȘ ȐȞȦ IJȠȣ 0,5 bar (g) țĮȚ ȝİȖȑșȠȣȢ ȝİȖĮȜȪIJİȡȠȣ IJȦȞ 25 mm Ȓ IJȘȢ 1 ȓȞIJıĮȢ İȝʌȓʌIJİȚ ıIJȚȢ įȚĮIJȐȟİȚȢ IJȘȢ İȣȡȦʌĮȧțȒȢ ȅįȘȖȓĮȢ ȖȚĮ IJȠȞ İȟȠʌȜȚıȝȩ ȣʌȩ ʌȓİıȘ (PED). x ȉȠ țİijȐȜĮȚȠ ȆȡȠįȚĮȖȡĮijȑȢ IJȠȣ ʌĮȡȩȞIJȠȢ İȖȤİȚȡȚįȓȠȣ ʌİȡȚȜĮȝȕȐȞİȚ ȠįȘȖȓİȢ ıȤİIJȚțȐ ȝİ IJȘȞ ȅįȘȖȓĮ PED. x ȅȚ ȝİIJȡȘIJȑȢ ʌȠȣ ʌİȡȚȖȡȐijȠȞIJĮȚ ıIJȠ ʌĮȡȩȞ İȖȤİȚȡȓįȚȠ ıȣȝȝȠȡijȫȞȠȞIJĮȚ ȝİ IJȘȞ İȣȡȦʌĮȧțȒ ȅįȘȖȓĮ 97/23/ǼȀ. x ǵȜĮ IJĮ ȡȠȩȝİIJȡĮ IJȘȢ Brooks Instrument ĮȞȒțȠȣȞ ıIJȘȞ ȠȝȐįĮ ȡİȣıIJȫȞ 1. x ȂİIJȡȘIJȑȢ ȝİȖĮȜȪIJİȡȠȚ Įʌȩ 25 mm Ȓ 1 ȓȞIJıĮ ıȣȝȝȠȡijȫȞȠȞIJĮȚ ȝİ IJȚȢ țĮIJȘȖȠȡȓİȢ ǿ, ǿǿ țĮȚ ǿǿǿ IJȘȢ ȅįȘȖȓĮȢ PED. x ȂİIJȡȘIJȑȢ ȝİȖȑșȠȣȢ 25 mm Ȓ 1 ȓȞIJıĮȢ Ȓ țĮȚ ȝȚțȡȩIJİȡȠȚ țĮIJĮıțİȣȐȗȠȞIJĮȚ ıȪȝijȦȞĮ ȝİ IJȠȣȢ țĮȞȩȞİȢ IJȘȢ IJȑȤȞȘȢ (SEP). ǼȣȡȦʌĮȧțȒ ȅįȘȖȓĮ ȖȚĮ IJȘȞ ȘȜİțIJȡȠȝĮȖȞȘIJȚțȒ ıȣȝȕĮIJȩIJȘIJĮ (EMC) ȅ (ȘȜİțIJȡȚțȩȢ/ȘȜİțIJȡȠȞȚțȩȢ) İȟȠʌȜȚıȝȩȢ IJȘȢ Brooks Instrument ʌȠȣ ijȑȡİȚ IJȠ ıȒȝĮ CE ȑȤİȚ ȣʌȠıIJİȓ İʌȚIJȣȤȫȢ IJȚȢ įȠțȚȝȑȢ ʌȠȣ ʌȡȠȕȜȑʌȠȣȞ ȠȚ įȚĮIJȐȟİȚȢ IJȘȢ ȅįȘȖȓĮȢ ȖȚĮ IJȘȞ ȘȜİțIJȡȠȝĮȖȞȘIJȚțȒ ıȣȝȕĮIJȩIJȘIJĮ (ȅįȘȖȓĮ 2004/108/EC ȖȚĮ IJȘȞ EMC). ȆȐȞIJȦȢ ȤȡİȚȐȗİIJĮȚ ȚįȚĮȓIJİȡȘ ʌȡȠıȠȤȒ ıIJȘȞ İʌȚȜȠȖȒ IJȠȣ țĮȜȦįȓȠȣ ıȒȝĮIJȠȢ ȖȚĮ IJȠȞ İȟȠʌȜȚıȝȩ ʌȠȣ ijȑȡİȚ IJȠ ıȒȝĮ CE. ȆȠȚȩIJȘIJĮ IJȦȞ țĮȜȦįȓȦȞ ıȒȝĮIJȠȢ, ıIJȣʌȚȠșȜȚʌIJȫȞ țĮȚ ȕȣıȝȐIJȦȞ țĮȜȦįȓȦȞ: Ǿ Brooks Instrument ʌȡȠıijȑȡİȚ ȣȥȘȜȒȢ ʌȠȚȩIJȘIJĮȢ țĮȜȫįȚĮ IJĮ ȠʌȠȓĮ ʌȜȘȡȠȪȞ IJȚȢ ʌȡȠįȚĮȖȡĮijȑȢ CE. Ȉİ ʌİȡȓʌIJȦıȘ ʌĮȡȠȤȒȢ įȚțȠȪ ıĮȢ țĮȜȦįȓȠȣ ıȒȝĮIJȠȢ, ȤȡȘıȚȝȠʌȠȚİȓIJİ țĮȜȫįȚȠ ȝİ ʌȜȒȡȘ șȦȡȐțȚıȘ 100% ıİ ȩȜĮ IJĮ ıȘȝİȓĮ. ǺȪıȝĮIJĮ IJȪʌȠȣ «D» Ȓ țȣțȜȚțȐ ʌȡȑʌİȚ ȞĮ ȑȤȠȣȞ ȝİIJĮȜȜȚțȒ șȦȡȐțȚıȘ. ȃĮ ȤȡȘıȚȝȠʌȠȚȘșȠȪȞ țĮIJȐ ʌȡȠIJȓȝȘıȘ ȝİIJĮȜȜȚțȠȓ ıIJȣʌȚȠșȜȓʌIJİȢ țĮȜȦįȓȦȞ ȖȚĮ IJȘ ıIJİȡȑȦıȘ IJȘȢ șȦȡȐțȚıȘȢ. ȃĮ ıȣȞįİșİȓ Ș șȦȡȐțȚıȘ IJȠȣ țĮȜȦįȓȠȣ ıIJȠ ȝİIJĮȜȜȚțȩ țȑȜȣijȠȢ Ȓ ıIJȣʌȚȠșȜȓʌIJȘ țĮȚ ȞĮ șȦȡĮțȚıIJİȓ țĮȚ ıIJĮ įȪȠ ȐțȡĮ țĮIJȐ 360 ȝȠȓȡİȢ. Ǿ șȦȡȐțȚıȘ ʌȡȑʌİȚ ȞĮ IJİȡȝĮIJȓȗİȚ ıİ ȖİȓȦıȘ İįȐijȠȣȢ. ȉĮ ȕȪıȝĮIJĮ ȐțȡȠȣ IJȘȢ ʌȜĮțȑIJĮȢ İȓȞĮȚ İț țĮIJĮıțİȣȒȢ ȝȘ ȝİIJĮȜȜȚțȐ. ȉĮ ȤȡȘıȚȝȠʌȠȚȠȪȝİȞĮ țĮȜȫįȚĮ ʌȡȑʌİȚ ȞĮ ȑȤȠȣȞ 100% șȦȡȐțȚıȘ ȖȚĮ ıȣȝȝȩȡijȦıȘ ȝİ IJȘȞ ʌȚıIJȠʌȠȓȘıȘ CE. Ǿ șȦȡȐțȚıȘ ʌȡȑʌİȚ ȞĮ IJİȡȝĮIJȓȗİȚ ıİ ȖİȓȦıȘ İįȐijȠȣȢ. īȚĮ IJȘ įȚȐIJĮȟȘ IJȦȞ ĮțȓįȦȞ: ȈȣȝȕȠȣȜİȣșİȓIJİ IJȠ ıȣȞȘȝȝȑȞȠ İȖȤİȚȡȓįȚȠ ȠįȘȖȚȫȞ. ǾȜİțIJȡȠıIJĮIJȚțȒ İțțȑȞȦıȘ (ESD) ȆȇȅĭȊȁǹȄǾ: Ǿ ıȣıțİȣȒ ĮȣIJȒ ʌİȡȚȑȤİȚ ȘȜİțIJȡȠȞȚțȐ İȟĮȡIJȒȝĮIJĮ IJĮ ȠʌȠȓĮ ȝʌȠȡȠȪȞ ȞĮ ȣʌȠıIJȠȪȞ İȪțȠȜĮ ȕȜȐȕİȢ Įʌȩ IJȠȞ ıIJĮIJȚțȩ ȘȜİțIJȡȚıȝȩ. ȆȡȑʌİȚ ȞĮ ĮțȠȜȠȣșȠȪȞIJĮȚ ȠȚ ȠȡșȑȢ įȚĮįȚțĮıȓİȢ ȤİȚȡȚıȝȠȪ țĮIJȐ IJȘȞ ĮijĮȓȡİıȘ, IJȠʌȠșȑIJȘıȘ Ȓ ȐȜȜȠ ȤİȚȡȚıȝȩ IJȦȞ İıȦIJİȡȚțȫȞ ʌȜĮțİIJȫȞ țĮȚ įȚĮIJȐȟİȦȞ. ǻȚĮįȚțĮıȓĮ ȤİȚȡȚıȝȠȪ: 1. ĬȑıIJİ IJȘ ıȣıțİȣȒ İțIJȩȢ IJȐıİȦȢ. 2. ĭȡȠȞIJȓıIJİ ȖȚĮ IJȘ ȖİȓȦıȘ IJȠȣ ʌȡȠıȦʌȚțȠȪ ȝİ ʌİȡȚțȐȡʌȚȠ Ȓ ȐȜȜȠ ĮıijĮȜȑȢ țĮȚ țĮIJȐȜȜȘȜȠ ȝȑıȠ ʌȡȚȞ IJȠʌȠșİIJȒıİIJİ, ĮijĮȚȡȑıİIJİ Ȓ ȡȣșȝȓıİIJİ țȐȡIJİȢ IJȣʌȦȝȑȞȦȞ țȣțȜȦȝȐIJȦȞ Ȓ ȐȜȜȘ İıȦIJİȡȚțȒ įȚȐIJĮȟȘ. 3. ȅȚ țȐȡIJİȢ IJȣʌȦȝȑȞȦȞ țȣțȜȦȝȐIJȦȞ ʌȡȑʌİȚ ȞĮ ȝİIJĮijȑȡȠȞIJĮȚ ıİ ıȣıțİȣĮıȓĮ Įʌȩ ĮȖȫȖȚȝȠ ȣȜȚțȩ. ȅȚ țȐȡIJİȢ įİȞ ʌȡȑʌİȚ ȞĮ ĮijĮȚȡİșȠȪȞ Įʌȩ IJȠ ʌȡȠıIJĮIJİȣIJȚțȩ ʌİȡȓȕȜȘȝĮ ʌĮȡȐ ȝȩȞȠ ĮȝȑıȦȢ ʌȡȚȞ Įʌȩ IJȘȞ IJȠʌȠșȑIJȘıȘ. ȅȚ țȐȡIJİȢ ʌȠȣ ĮijĮȚȡȑșȘțĮȞ ʌȡȑʌİȚ ȞĮ IJȠʌȠșİIJȘșȠȪȞ ĮȝȑıȦȢ ıİ ʌȡȠıIJĮIJİȣIJȚțȒ ıȣıțİȣĮıȓĮ ȖȚĮ ȝİIJĮijȠȡȐ, ĮʌȠșȒțİȣıȘ Ȓ İʌȚıIJȡȠijȒ ıIJȠ İȡȖȠıIJȐıȚȠ. ȆĮȡĮIJȘȡȒıİȚȢ: Ǿ ȪʌĮȡȟȘ İȟĮȡIJȘȝȐIJȦȞ İȣĮȓıșȘIJȦȞ ıIJĮ ijĮȚȞȩȝİȞĮ ESD (ȘȜİțIJȡȠıIJĮIJȚțȒȢ İțțȑȞȦıȘȢ) įİȞ İȓȞĮȚ ȝȠȞĮįȚțȩ ȤĮȡĮțIJȘȡȚıIJȚțȩ IJȘȢ ıȣıțİȣȒȢ ĮȣIJȒȢ. ȅȚ ʌİȡȚııȩIJİȡİȢ ıȪȖȤȡȠȞİȢ ȘȜİțIJȡȠȞȚțȑȢ ıȣıțİȣȑȢ ʌİȡȚȑȤȠȣȞ İȟĮȡIJȒȝĮIJĮ IJİȤȞȠȜȠȖȓĮȢ ȝİIJĮȜȜȚțȫȞ ȠȟİȚįȓȦȞ (NMOS, SMOS țȐ.). Ǿ ʌİȓȡĮ ȑȤİȚ ĮʌȠįİȓȟİȚ ȩIJȚ ȝȚĮ ȝȚțȡȒ ʌȠıȩIJȘIJĮ ıIJĮIJȚțȠȪ ȘȜİțIJȡȚıȝȠȪ Įȡțİȓ ȖȚĮ ȞĮ ʌȡȠțĮȜȑıİȚ ȕȜȐȕİȢ Ȓ ȞĮ țĮIJĮıIJȡȑȥİȚ IJȚȢ ıȣıțİȣȑȢ ĮȣIJȑȢ. ǼȟĮȡIJȒȝĮIJĮ ʌȠȣ ȣʌȑıIJȘıĮȞ ȕȜȐȕȘ, ĮțȩȝȘ țĮȚ ĮȞ ȝȠȚȐȗȠȣȞ ȞĮ ȜİȚIJȠȣȡȖȠȪȞ ıȦıIJȐ, țȚȞįȣȞİȪȠȣȞ Įʌȩ ʌȡȫȚȝȘ ĮıIJȠȤȓĮ. A-9 Section A - Essential Instructions Installation and Operation Manual Flow Controllers for Gas and Liquid Service X-VA-FC-eng Part Number: 541B045AAG December, 2015 Hungarian AlapvetĘ utasítások ElĘször olvassa el ezeket! A Brooks Instrument olyan módon tervezi, gyártja és teszteli termékeit, hogy azok megfeleljenek számos belföldi és nemzetközi szabványnak. Ezeket a berendezéseket megfelelĘen kell telepíteni, üzemeltetni és karbantartani ahhoz, hogy mindenképpen a normál mĦködési tartományuknak megfelelĘen üzemelhessenek. Az alábbi utasításokat be kell tartani, és be kell építeni a munkavédelmi programba a Brooks Instrument termékeinek telepítése, üzemeltetése és karbantartása során. A megfelelĘ teljesítmény garantálása érdekében kizárólag szakképzett személyzet végezze a termék telepítését, üzemeltetését, frissítését, programozását és karbantartását. Valamennyi utasítást el kell olvasni a termék telepítése, üzemeltetése és szervizelése elĘtt. Amennyiben ez a kézikönyv nem a megfelelĘ kiadvány, a hátsó borítón keresse meg a helyi forgalmazót, és további tájékoztatásért lépjen kapcsolatba vele. ėrizze meg ezt a kézikönyvet késĘbbi tájékoztatásként. FIGYELEM: Ne mĦködtesse a berendezést az üzemeltetési utasításban megadott üzemi tartományokon túl. Ennek megsértése súlyos személyi sérüléshez vagy a berendezés meghibásodásához vezethet. x Amennyiben a gépkönyv utasításai nem egyértelmĦek, lépjen kapcsolatba Brooks Instrument képviselĘjével, hogy tisztázzák a problémát. x Tartsa be a berendezésen feltüntetett vagy azzal együtt szállított összes figyelmeztetést, felhívást és utasítás. x A megfelelĘ telepítési utasításban megadott utasítások valamint a hatályos helyi és nemzeti elĘírások szerint telepítse a berendezést. A termékeket kizárólag a megfelelĘ elektromos és nyomásellátó forrásra kösse. x Menete: (1) Lassan helyezze nyomás alá a rendszert. Lassanként nyissa ki az üzemi szelepeket az áramlásingadozás elkerülése érdekében. (2) EllenĘrizze, nincs-e szivárgás az áramlásmérĘ be-, és kimeneti bekötéseinél. Ha nincs szivárgás, töltse fel a rendszert az üzemi nyomásra. x Szervizelés elĘtt mindenképpen ellenĘrizze, hogy az üzemi vezeték nincs-e nyomás alatt. Amennyiben cserealkatrészekre van szükség, mindenképpen szakképzett személynek kell kezelnie a Brooks Instrument által meghatározott cserealkatrészeket. A nem engedélyezett alkatrészek és tevékenységek befolyásolhatják a termék teljesítményét, illetve veszélyeztethetik a biztonságos üzemeltetést. A pusztán hasonló alkatrészekkel történĘ helyettesítés tüzet, áramütésveszélyt vagy elégtelen mĦködést eredményezhet. x A berendezés összes ajtaja mindenképpen legyen zárva, a védĘburkolatok pedig legyenek a helyükön az áramütés és a személyi sérülések elkerülése érdekében, kivéve, ha szakképzett szakember végez rajta karbantartási munkákat. FIGYELEM: Folyadékot áramoltató berendezések esetében, ha bármilyen okból el kell zárni a berendezés melletti ki-, és belépĘ szelepeket, a berendezést teljesen le kell üríteni. Ennek elmulasztása a folyadék hĘtágulását okozhatja, ami károsíthatja a berendezést, és személyi sérüléshez vezethet. Nyomástartó berendezésekre vonatkozó európai irányelv (PED) Minden 0,5 bar-nál (g) magasabb belsĘ nyomású és 25 mm-nél vagy 1 hüvelyknél nagyobb nyomástartó berendezés a nyomástartó berendezésekre vonatkozó európai irányelv (PED) hatálya alá tartozik. x A gépkönyv „MĦszaki adatok” fejezete tartalmaz a PED irányelvre vonatkozó utasításokat. x A gépkönyvben megadott mérĘeszközök megfelelnek a 97/23/EK EU irányelvnek. x Minden Brooks átfolyásmérĘ az 1-es folyadékcsoportba tartozik. x A 25 mm-nél vagy 1 hüvelyknél nagyobb mérĘeszközök megfelelnek a PED I, II, vagy III kategóriának. x A 25 mm-es illetve 1 hüvelykes vagy kisebb mérĘeszközök az elfogadott mérnöki gyakorlatot (SEP) követik. Elektromágneses kompatibilitásra vonatkozó európai irányelv (EMC) A Brooks Instrument CE jelölést kiérdemelt (elektromos/elektronikus) berendezései sikeresen teljesítették az elektromágneses kompatibilitási követelményeket (2004/108/EC sz. EMC irányelv) vizsgáló teszteket. Ugyanakkor különös figyelmet kell fordítani a CE jelölésĦ berendezésekhez felhasznált jelkábelek kiválasztására. A jelkábelek, kábelösszekötĘk, csatlakozók minĘsége: A Brooks Insturment magas minĘségĦ kábeleket kínál, melyek megfelelnek a CE minĘsítés követelményeinek. Amennyiben saját jelkábelt alkalmaznak, olyat kell választani, amely 100%-os árnyékolással, teljes mértékben szĦrt. A „D” vagy „kör alakú” csatlakozóknak fémárnyékolóval árnyékoltnak kell lennie. Szükség esetén fém kábelösszekötĘket kell alkalmazni a kábelszĦrĘ rögzítésére. A kábelszĦrĘt a fém házhoz vagy hüvelyhez kell csatlakoztatni és mindkét felén 360°-ban le kell árnyékolni. Az árnyékolásnak földelésben kell végzĘdnie. A kártyákhoz tartozó csatlakozók szabványosan nem fémesek. Az alkalmazott kábeleknek 100%-és árnyékolással szĦrteknek kell lenniük, hogy megfeleljenek a CE minĘsítésnek. Az árnyékolásnak földelésben kell végzĘdnie. ÉrintkezĘ konfiguráció: Lásd a mellékelt kezelési utasítást. Elektrosztatikus kisülés (ESD) VIGYÁZAT: A készülék olyan alkatrészeket tartalmaz, melyek hajlamosak a sztatikus elektromosság okozta károsodásra. Be kell tartani a megfelelĘ eljárásokat a belsĘ áramköri kártyák és eszközök eltávolítása, behelyezése vagy egyéb kezelése során. Kezelési eljárás: 1. A berendezést áramtalanítani kell. 2. A személyt földelni kell csuklópánttal vagy egyéb biztonságos és a célra alkalmas eszközzel, mielĘtt áramköri kártyát vagy egyéb belsĘ eszközt telepítene, venne ki, vagy állítana be. 3. A nyomtatott áramköri kártyákat vezetĘképes csomagolásban kell szállítani. A kártyák kizárólag közvetlenül a behelyezés elĘtt vehetĘk ki a védĘburkolatból. A kiszerelt kártyát haladéktalanul el kell helyezni a mozgatásra, raktározásra vagy a gyári visszaszállításra szolgáló védĘcsomagolásba. Megjegyzések: Nem egyedi jelenség, hogy a készülékben elektrosztatikus kisülésre (ESD) érzékeny alkatrészek találhatók. A legtöbb korszerĦ elektronikus eszközben fémoxid technológiás alkatrészek (NMOS, SMOS stb.) találhatók. A tapasztalatok azt igazolják, hogy még kis mértékĦ sztatikus elektromosság is károsíthatja, vagy tönkreteheti ezeket az eszközöket. A károsodott alkatrészek, még ha látszólag megfelelĘen mĦködnek is, kezdĘdĘ hibára utalnak. A-10 Section A - Essential Instructions Installation and Operation Manual X-VA-FC-eng Part Number: 541B045AAG December, 2015 Flow Controllers for Gas and Liquid Service Italian Istruzioni fondamentali Leggerle subito! La Brooks Instrument progetta, fabbrica e collauda i propri prodotti in maniera tale che siano conformi ai vari standard nazionali ed internazionali. Tali apparecchiature devono essere installate, messe in esercizio e tenute in manutenzione in maniera adeguata affinché operino in conformità alle loro normali specifiche di funzionamento. Le seguenti istruzioni devono essere rispettate ed inserite nel programma di tutela sul lavoro durante l’installazione, il funzionamento e la manutenzione dei prodotti Brooks Instrument. x Per garantire un adeguato rendimento l'installazione, il funzionamento, l’aggiornamento, la programmazione e la manutenzione del prodotto devono essere eseguiti esclusivamente da personale specializzato. x Leggere tutte le istruzioni prima dell’installazione, utilizzo e manutenzione del prodotto. Se questo manuale non è quello relativo al Vostro prodotto, cercare sul retro della copertina il distributore locale e contattarlo per ulteriori informazioni. Conservare il presente manuale per future consultazioni. ATTENZIONE: Non utilizzare questo strumento in condizioni che eccedono le specifiche riportate nel Manuale d’Uso. L’inosservanza può causare gravi lesioni alle persone e/o danni all’apparecchiatura. x Qualora le istruzioni del manuale non siano chiare, contattare un rappresentante della Brooks Instrument per chiarire il problema. x Rispettare tutti gli avvisi, le istruzioni e gli avvertimenti riportati sull’apparecchiatura o forniti insieme ad essa. x Installare l’apparecchiatura in base alle istruzioni riportate nel Manuale d’Uso e alle prescrizioni locali e nazionali in vigore. Collegare i prodotti esclusivamente ad un’adeguata sorgente di pressione ed alimentazione elettrica. x Procedimento: (1) mettere lentamente sotto pressione il sistema. Aprire lentamente le valvole di servizio per evitare l’oscillazione del flusso. (2) Controllare che non ci siano perdite nei punti di connessione in entrata e in uscita del misuratore di flusso. Se non ci sono perdite, caricare il sistema alla pressione d’esercizio. x Prima di effettuare manutenzione controllare che la linea di processo non sia sotto pressione. Se avete bisogno di pezzi di ricambio, il personale specializzato deve usare i pezzi di ricambio definiti dalla Brooks Instrument. Attività e pezzi di ricambio non autorizzati possono influire sul rendimento del prodotto e comprometterne il funzionamento in sicurezza. La sostituzione con pezzi di ricambio non originali può causare incendi, pericolo di scosse elettriche o funzionamento improprio. x Tutti gli sportelli dell’impianto devono essere chiusi, le cappe di protezione devono essere al loro posto per evitare scosse elettriche e lesioni personali, tranne quando il personale specializzato esegue lavori di manutenzione. ATTENZIONE: In caso di apparecchiature in cui scorre un liquido, se per qualsiasi motivo bisogna chiudere le valvole d’entrata e d’uscita accanto all’apparecchiatura, allora si deve svuotare completamente l’apparecchiatura. L’inosservanza può causare la dilatazione termica del liquido che può danneggiare l’apparecchiatura e provocare lesioni alle persone. Direttiva europea relativa alle apparecchiature a pressione (PED) Ogni apparecchiatura a pressione con pressione interna maggiore di 0,5 bar (g) e più grande di 25 mm o di 1 pollice ricade nell’ambito della Direttiva Europea relativa alle apparecchiature a pressione (PED). x Il capitolo „Dati tecnici” del manuale contiene le disposizioni relative alla direttiva PED. x Gli strumenti di misura descritti nel presente manuale sono conformi alla Direttiva UE 97/23/CE. x Ogni flussimetro Brooks appartiene al gruppo di fluidi 1. x Gli strumenti di misura maggiori di 25 mm o di 1 pollice sono conformi alla categoria I, II o III della PED. x Gli strumenti di misurazione minori di 25 mm o di 1 pollice rientrano nella categoria SEP (Sound Engineering Practice). Direttiva europea relativa alla compatibilità elettromagnetica (EMC) Le apparecchiature (elettriche/elettroniche) Brooks Instrument dispongono del marchio CE ed hanno superato positivamente i test per i requisiti di compatibilità elettromagnetica (Direttiva EMC 2004/108/EC). In ogni caso bisogna prestare particolare attenzione alla scelta dei cavi di segnale utilizzati per le apparecchiature con marchio CE. Qualità dei cavi di segnale, dei pressacavi e dei connettori: La Brooks Instrument offre cavi d’alta qualità conformi ai requisiti della certificazione CE. Qualora vengano utilizzati cavi di segnale propri, devono essere scelti con schermatura al 100% e interamente filtrati. I connettori „D” o „rotondi” devono essere schermati con schermatura metallica. In caso di necessità bisogna utilizzare pressacavi metallici di collegamento per fissare la schermatura del cavo. La schermatura del cavo deve far contatto col guscio metallico o col pressacavo; il cavo deve essere schermato su entrambi i lati a 360°. La schermatura deve essere effettuata con messa a terra. I connettori Card Edge normalmente non sono di metallo. I cavi utilizzati devono essere filtrati con schermatura al 100% per essere conformi alla marcatura CE. La schermatura deve essere effettuata con messa a terra. Configurazione pin: Vedi Manuale d’uso allegato. Scarica elettrostatica (ESD) ATTENZIONE: Il dispositivo contiene componenti elettronici che possono essere danneggiati da elettricità statica. Bisogna rispettare le adeguate procedure durante la rimozione, l’installazione o altra manovra delle schede del circuito elettrico interno. Procedura di manovra: 1. Togliere alimentazione elettrica all’apparecchiatura. 2. La persona deve essere collegata a terra con una cerniera o con altri strumenti di sicurezza e adeguati allo scopo prima di installare, togliere o impostare la scheda del circuito elettrico o altri dispositivi interni. 3. Le schede del circuito stampato devono essere spedite in contenitori conduttivi. Le schede devono essere tolte dal rivestimento protettivo esclusivamente prima dell’installazione. Le schede confezionate devono essere collocate immediatamente nell’imballaggio protettivo per la movimentazione, l’immagazzinamento o resa alla fabbrica. Note: È un fenomeno comune che nei dispositivi di questo tipo si trovino componenti sensibili alla scarica elettrostatica (ESD). Nella maggior parte degli strumenti elettronici moderni si trovano componenti tecnologici metallo-ossido (NMOS, SMOS, ecc.). Le esperienze dimostrano che l’elettrostaticità anche in piccola misura può danneggiare o rovinare gli strumenti. I componenti danneggiati, anche se all’apparenza funzionano correttamente, potrebbero manifestare il difetto rapidamente. A-11 Section A - Essential Instructions Installation and Operation Manual Flow Controllers for Gas and Liquid Service X-VA-FC-eng Part Number: 541B045AAG December, 2015 Latvian SvarƯga instrukcija Pirms turpinƗt izlasiet! „Brooks Instrument” projektƝ, ražo un pƗrbauda savus ražojumus atbilstoši daudziem nacionƗlajiem un starptautiskajiem standartiem. Lai nodrošinƗtu šo izstrƗdƗjumu turpmƗku darbƯbu atbilstoši noteiktajiem parametriem, tie ir pareizi jƗuzstƗda, jƗlieto un jƗapkopj. UzstƗdot, lietojot „Brooks Instrument” izstrƗdƗjumus un veicot to apkopi, ir jƗievƝro šie norƗdƯjumi un jƗiekƺauj tie jnjsu drošƯbas programmƗ. x Lai nodrošinƗtu pienƗcƯgu izstrƗdƗjuma sniegumu, izstrƗdƗjuma uzstƗdƯšanu, lietošanu, atjauninƗšanu, programmƝšanu un apkopi uzticiet veikt tikai kvalificƝtam personƗlam. x Pirms izstrƗdƗjuma uzstƗdƯšanas, lietošanas un apkalpošanas izlasiet visus norƗdƯjumus. Ja šƯ instrukciju rokasgrƗmata nav pareizƗ, izstrƗdƗjumam atbilstošƗ rokasgrƗmata, lnjdzu skat. aizmugurƝjo vƗku, kur ir sniegta vietƝjƗ tirdzniecƯbas biroja kontaktinformƗcija. BRƮDINƖJUMS! Nelietot instrumentu Ɨrpus Instrukciju un lietošanas rokasgrƗmatƗ norƗdƯtajiem parametriem. ŠƯ brƯdinƗjuma neievƝrošanas rezultƗtƗ var rasties traumas un / vai aprƯkojuma bojƗjumi. x Ja jnjs nesaprotat kƗdu no instrukcijƗm, sazinieties ar „Brooks Instrument” pƗrstƗvi un lnjdziet izskaidrot to. x IevƝrojiet visus brƯdinƗjumus, piesardzƯbas mƝrus un instrukcijas, kas norƗdƯti uz izstrƗdƗjuma vai piegƗdƗti kopƗ ar to. x UzstƗdiet aprƯkojumu tƗ, kƗ tas norƗdƯts attiecƯgajƗ instrukciju rokasgrƗmatƗ iekƺautajƗ uzstƗdƯšanas instrukcijƗ un atbilstoši piemƝrojamajƗm vietƝjƗm un nacionƗlajƗm normƗm. Pievienojiet visus izstrƗdƗjumus pareiziem elektriskajiem un spiediena avotiem. x Lietošana: (1) LƝnƗm uzsƗciet plnjsmu sistƝmƗ. Lai izvairƯtos no straujiem plnjsmas kƗpumiem, lƝnƗm atveriet procesa vƗrstus. (2) PƗrbaudiet, vai nav noplnjdes ap plnjsmas mƝrƯtƗja ieplnjdes un izplnjdes savienojumiem. Ja noplnjdes nav, uzstƗdiet sistƝmƗ darba spiedienu. x PƗrliecinieties par to, lai pirms instrumenta tehniskƗs apkopes bnjtu likvidƝts procesa lƯnijas spiediens. Ja ir nepieciešams veikt kƗdu daƺu nomaiƼu, nodrošiniet, lai tiktu izmantotas „Brooks Instrument” norƗdƯtƗs daƺas un daƺu nomaiƼu veiktu kvalificƝts personƗls. Neatƺautu daƺu un procednjru izmantošana var ietekmƝs ražojuma sniegumu un samazinƗt procesa drošƯbu. LƯdzƯgu, bet ne identisku daƺu nomaiƼas lietošana var izraisƯt ugunsgrƝka, elektrisko traucƝjumu riskus un nepareizu izstrƗdƗjuma darbƯbu. x Nodrošiniet, lai bnjtu aizvƝrtas visas durvis un bnjtu pareizi uzstƗdƯti visi aizsargpƗrsegumi, tƗdƝjƗdi novƝršot elektrošoka un traumu risku. IzƼƝmums ir gadƯjumi, kad kvalificƝts personƗls veic ražojuma apkopi. BRƮDINƖJUMS! Ja šƷidrƗs plnjsmas ierƯþu tuvumƗ esošos ieplnjdes un izplnjdes vƗrstus kƗda iemesla dƝƺ ir jƗaizver, no ierƯcƝm ir jƗizlaiž viss šƷidrums. PretƝjƗ gadƯjumƗ šƷidrums var termiski izplesties, pƗrraut ierƯci un radƯt traumas. Eiropas spiedieniekƗrtu direktƯva (PED) Uz visƗm spiedieniekƗrtƗm, kuru iekšƝjais spriegums pƗrsniedz 0,5 bar (g) un ir lielƗkas par 25 mm jeb 1” (collu), attiecas Eiropas spiedieniekƗrtu direktƯva (PED). x ŠƯs rokasgrƗmatas tehnisko parametru nodaƺƗ ir sniegtas a PED DirektƯvu saistƯtƗs instrukcijas. x ŠajƗ rokasgrƗmatƗ aprakstƯtie mƝrƯtƗji atbilst EN DirektƯvas 97/23/EK prasƯbƗm. x Visi „Brooks Instrument” plnjsmas mƝrƯtƗji ietilpst 1. šƷidrumu grupƗ. x Uz 25 mm jeb 1” (collu) maziem un mazƗkiem mƝrƯtƗjiem attiecas labas inženierijas prakse (SEP). x 25 mm jeb 1” (collu) mazi vai mazƗki mƝrƯtƗji atbilst PED kategorijai I, II vai III. Eiropas elektromagnƝtiskƗs savietojamƯbas direktƯva (EMS) Brooks Instrument” (elektriskƗs / elektroniskƗs) iekƗrtas ar CE zƯmi ir izturƝjušas pƗrbaudi un atzƯtas par atbilstošƗm Eiropas elektromagnƝtiskƗs savietojamƯbas direktƯvas (EMS) prasƯbƗm (EMS 2004/108/EC) TomƝr, izvƝloties signƗlkabeli, kas tiks lietots kopƗ ar CE marƷƝjuma iekƗrtu, ir jƗievƝro Ưpaša uzmanƯbaSignƗlkabeƺa, kabeƺa blƯvslƝgu un savienotƗju kvalitƗte: „Brooks Instrument” piegƗdƗ augstas kvalitƗtes kabeƺus, kas atbilst CE sertifikƗcijas tehniskajiem parametriem. Ja jnjs lietojat pats savu signƗlkabeli, tam ir jƗbnjt pilnƯbƗ, 100% ekranizƝtam. „D” un „apaƺƗ” tipa savienotƗjiem ir jƗbnjt aprƯkotiem ar metƗla ekranizƝjumu. Ja nepieciešams, ir jƗizmanto metƗla blƯvslƝgi ar kabeƺa ekranizƝjuma skavojumu. Kabeƺa ekranizƝjumam ir jƗbnjt savienotam ar metƗla apvalku un abƗs pusƝs aizsargƗtam 360 grƗdu diapazonƗ. EkranizƝjumam ir jƗbeidzas pie iezemƝjuma. „Card Edge” savienotƗji standarta izpildƯjumƗ ir nemetƗla. Kabeƺiem ir jƗbnjt pƗrklƗtiem ar 100% ekranizƝjumu, lai tie atbilstu CE sertifikƗcijas prasƯbƗm. EkranizƝjumam ir jƗbeidzas pie iezemƝjuma. AttiecƯbƗ uz tapu konfigurƗciju: skat. pievienoto instrukciju rokasgrƗmatu. ESD (elektrostatiskƗ izlƗde) IEVƜROT PIESARDZƮBU! Šis instruments satur elektriskos komponentus, kas ir jutƯgi pret statisko elektrƯbu. IzƼemot un uzstƗdot iekšƝjƗs ƷƝdes plates un ierƯces vai kƗ citƗdi darbojoties ar tƗm, ir jƗievƝro noteikta darba kƗrtƯba. Darba kƗrtƯba: 1. IekƗrta jƗatslƝdz no barošanas. 2. Pirms jebkƗdas drukƗtas shƝmas kartes vai citas iekšƝjƗs ierƯces uzstƗdƯšanas, izƼemšanas vai regulƝšanas personƗlam, kas veiks šos darbus, ir jƗbnjt iezemƝtam, piem., izmantojot aproces vai citus drošus, piemƝrotus lƯdzekƺus. 3. DrukƗtƗs shƝmas kartes ir jƗtransportƝ vadošƗ iepakojumƗ. PlƗksnes no aizsargkorpusa drƯkst izƼemt tikai tieši pirms uzstƗdƯšanas. TransportƝjot, uzglabƗjot vai atgriežot rnjpnƯcƗ no izƼemtƗs plƗksnes ir nekavƝjoties jƗievieto aizsargiepakojumƗ. KomentƗri Instruments nav unikƗls tajƗ aspektƗ, ka tas satur pret ESD (elektrostatisko izlƗdi) jutƯgus komponentus. Vairums mnjsdienu elektroiekƗrtu satur komponentus, kuru ražošanƗ izmantota metƗla oksƯdu tehnoloƧijas (NMOS, SMOS u.c.). Pieredze rƗda, ka pat neliels daudzums statiskƗs elektrƯbas var nodarƯt bojƗjumus šƗdƗm ierƯcƝm vai pilnƯbƗ sabojƗt tƗs. BojƗtie komponenti pat tad, ja tie šƷietami darbojas pareizi, ir pakƺauti ƗtrƗkai atteicei. A-12 Section A - Essential Instructions Installation and Operation Manual X-VA-FC-eng Part Number: 541B045AAG December, 2015 Flow Controllers for Gas and Liquid Service Lithuanian Pagrindinơs instrukcijos Perskaitykite prieš tĊsdami! „Brooks Instrument“ projektuoja, gamina ir išbando savo gaminius, kad jie atitiktǐ Ƴvairius nacionalinius ir tarptautinius standartus. Šie gaminiai turi bnjti tinkamai montuojami, eksploatuojami ir prižinjrimi, kad ir toliau veiktǐ pagal jiems bnjdingus techninius parametrus. Toliau pateiktǐ nurodymǐ reikia laikytis ir Ƴtraukti juos Ƴ saugos programą montuojant, eksploatuojant ir prižinjrint „Brooks Instrument“ produktus. x Siekiant užtikrinti tinkamą veikimą, montuoti, eksploatuoti, naujinti, programuoti ir prižinjrơti gaminƳ turi tik kvalifikuoti darbuotojai. x Perskaitykite visus nurodymus prieš montuodami, eksploatuodami ir prižinjrơdami gaminƳ. Jei gavote netinkamą instrukciją, galiniame jos viršelyje žinjrơkite vietinơs prekybos atstovybơs kontaktinĊ informaciją. Išsaugokite šią instrukciją pasižinjrơjimui ateityje. x x x x x x ƲSPƠJIMAS: nenaudokite šio prietaiso viršydami instrukcijoje ir eksploatacijos vadove nurodytus techninius duomenis. Nesilaikydami šio Ƴspơjimo galite sunkiai susižeisti ir (arba) sugadinti Ƴrangą. Jei nesuprantate kokiǐ nors nurodymǐ, kreipkitơs Ƴ „Brooks Instrument“ atstovą, kad paaiškintǐ. Paisykite visǐ Ƴspơjimo, perspơjimǐ ir nurodymǐ, pažymơtǐ ant gaminio arba pateiktǐ su juo. Ʋrangą montuokite taip, kaip nurodyta atitinkamos instrukcijos montavimo nurodymuose arba taikomuose vietiniuose ar nacionaliniuose kodeksuose. Visus gaminius junkite prie tinkamǐ elektros ir slơgio šaltiniǐ. Eksploatacija: (1) lơtai Ƴjunkite srautą Ƴ sistemą. Lơtai atidarykite proceso vožtuvus, kad išvengtumơte srauto antplnjdžiǐ. (2) Patikrinkite, ar nơra nuotơkiǐ aplink srauto matuoklio Ƴleidimo ir išleidimo jungtis. Jei nuotơkiǐ nơra, sukurkite sistemoje darbinƳ slơgƳ. Prieš atlikdami priežinjros darbus bnjtinai pašalinkite slơgƳ proceso linijoje. Jei reikia pakeisti dalis, užtikrinkite, kad kvalifikuoti darbuotojai naudotǐ „Brooks Instrument“ nurodytas pakaitines dalis. Netinkamos dalys ir procednjros gali pakenkti gaminio veikimui ir kelti pavojǐ saugiai jnjsǐ proceso eksploatacijai. Tik panašiai atrodantys pakaitalai gali sąlygoti gaisrą, elektros pavojus ar netinkamą veikimą. Užtikrinkite, kad visos Ƴrangos durelơs bnjtǐ uždarytos, o apsauginiai dangþiai uždơti, kad išvengtumơte elektros smnjgio ir sužeidimǐ, išskyrus kai kvalifikuoti darbuotojai atlieka priežinjros darbus. ƲSPƠJIMAS: naudojant skysto srauto Ƴrenginius, jei dơl kokios nors priežasties prireikia uždaryti šalia Ƴrenginio esanþius Ƴleidimo ir išleidimo vožtuvus, iš Ƴrenginio reikia išleisti visą skystƳ. To nepadarius galimas šiluminis skysþio plơtimasis, galintis sugadinti ƳrenginƳ ir sužeisti žmonơs. Europos slơginơs Ƴrangos direktyva (PED) Visa slơginơ Ƴranga, kurios vidinis slơgis didesnis nei 0,5 bar (g), o dydis didesnis nei 25 mm arba 1 colis, yra reglamentuojama slơginơs Ƴrangos direktyvos (PED). x Šios instrukcijos dalyje „Techniniai duomenys“ pateikiami nurodymai, susijĊ su PED direktyva. x Šioje instrukcijoje aprašyti matuokliai atitinka Europos Sąjungos direktyvą 97/23/EB. x Visi „Brooks Instrument“ srauto matuokliai priklauso 1 skysþiǐ grupei. x Didesni nei 25 mm arba 1 colis matuokliai atitinka PED I, II arba III kategoriją. x 25 mm arba 1 colio ar mažesni matuokliai atitinka tinkamą inžinerijos praktiką (SEP). Europoje taikomi elektromagnetinio suderinamumo (EMC) reikalavimai CE ženklu pažymơta „Brooks Instrument“ (elektrinơ / elektroninơ) Ƴranga buvo sơkmingai išbandyta pagal elektromagnetinio suderinamumo reikalavimus (EMC direktyvą 2004/108/EC). Bet reikia ypatingo dơmesio renkantis signalizavimo kabelƳ, kuris bus naudojamas su CE ženklu pažymơta Ƴranga. Signalizavimo kabelio, kabeliǐ riebokšliǐ ir jungþiǐ kokybơ: „Brooks Instrument“ tiekia kokybiškus kabelius, kurie atitinka CE sertifikavimo specifikacijas. Jei naudojate savo signalizavimo kabelƳ, jis turi bnjti visiškai ir visas ekranuotas 100 % ekranu. Naudojamos „D“ arba „apskrito“ tipo jungtys turi bnjti ekranuotos metaliniu ekranu. Jei taikoma, reikia naudoti metalinius kabeliǐ riebokšlius, užtikrinanþius kabelio ekrano suspaudimą. Kabelio ekraną reikia jungti prie metalinio apvalkalo ar riebokšlio ir ekranuoti abiejuose galuose 360 laipsniǐ. Ekranas turi baigtis Ƴžeminimu. Standartinơs kraštinơs jungtys yra ne metalinơs. Naudojami kabeliai turi bnjti ekranuoti 100 % ekranu, kad atitiktǐ CE sertifikavimą. Ekranas turi baigtis Ƴžeminimu. Keturiǐ kontaktǐ konfignjracija: žr. pridơtą instrukciją. ESD (elektrostatinis išlydis) PERSPƠJIMAS: šiame prietaise yra elektroniniǐ komponentǐ, kuriuos gali sugadinti statinơ elektra. Išimant ar Ƴdedant vidines spausdintines plokštes ar Ƴrenginius, arba atliekant su jomis kitus darbus, reikia laikytis tinkamǐ darbo procednjrǐ. Darbo procednjra: 1. Atjunkite Ƴrenginio maitinimą. 2. Darbuotojai turi pasirnjpinti Ƴžeminimu naudodami riešo juostelĊ ar kitas saugias tinkamas priemones prieš Ƴdơdami, išimdami ar reguliuodami bet kokią spausdintinơs plokštơs kortelĊ ar kitą vidinƳ komponentą. 3. Spausdintinơs plokštơs korteles reikia transportuoti laidžiame konteineryje. Neleidžiama išimti plokštơs iš apsauginio dơklo, nebent prieš pat Ƴdơjimą. Išimtas plokštes reikia nedelsiant Ƴdơti Ƴ apsauginƳ konteinerƳ transportavimui ar saugojimui arba grąžinti Ƴ gamyklą. Pastabos Šis instrumentas nơra unikalus dơl jame esanþiǐ ESD (elektrostatiniam išlydžiui) jautriǐ komponentǐ. Daugelyje šiuolaikiniǐ elektroniniǐ gaminiǐ yra komponentǐ, kuriuose naudojama metalo oksidǐ technologija (NMOS, SMOS ir pan.). Patirtis rodo, kad net ir mažas statinơs elektros kiekis gali pakenkti tokiems gaminiams ar juos sugadinti. Sugadinti komponentai, net jei atrodo, kad jie veikia tinkamai, anksti nustoja veikti. A-13 Section A - Essential Instructions Installation and Operation Manual Flow Controllers for Gas and Liquid Service X-VA-FC-eng Part Number: 541B045AAG December, 2015 Polish Zalecenia wstĊpne Prosimy przeczytaü przed rozpoczĊciem uĪytkowania! Brooks Instrument projektuje, wytwarza i testuje swoje produkty tak, aby speániaáy wymagania licznych norm krajowych i miĊdzynarodowych. Te produkty muszą byü poprawnie instalowane, obsáugiwane oraz konserwowane, aby zapewniü ich prawidáowe dziaáanie zgodnie ze specyfikacją techniczną. Podczas instalowania, obsáugiwania i konserwowania produktów firmy Brooks Instrument naleĪy przestrzegaü nastĊpujących zaleceĔ: x Aby zapewniü wáaĞciwe dziaáanie sprzĊtu, instalacja, obsáuga, aktualizacje, programowanie i konserwacja powinny byü wykonywane przez przeszkolony personel. x Przed instalacją, obsáugą i czynnoĞciami serwisowymi naleĪy zapoznaü siĊ ze wszystkimi zaleceniami producenta. Aby uzyskaü instrukcjĊ obsáugi odpowiednią dla danego sprzĊtu naleĪy skontaktowaü siĊ z lokalnym przedstawicielem handlowym producenta. InstrukcjĊ obsáugi naleĪy zachowaü do póĨniejszego uĪycia. OSTRZEĩENIE: Nie wolno przekraczaü podanych w instrukcji zakresów dziaáania urządzenia. Nieprzestrzeganie tego zalecenia moĪe doprowadziü do powaĪnego zagroĪenia Īycia lub zdrowia personelu i / lub uszkodzenia sprzĊtu. x x x x x x JeĪeli jakieĞ zalecenia w instrukcji obsáugi urządzenia są niezrozumiaáe, prosimy o skontaktowanie siĊ z przedstawicielem firmy Brooks Instrument, aby wyjaĞniü problem. NaleĪy postĊpowaü biorąc pod uwagĊ wszystkie ostrzeĪenia, uwagi i zalecenia umieszczone na produkcie lub doáączone do niego. InstalacjĊ urządzenia naleĪy przeprowadziü zgodnie z zaleceniami zawartymi w instrukcji instalacji oraz z obowiązującymi lokalnymi i narodowymi oznaczeniami. Wszystkie urządzenia moĪna podáączaü wyáącznie do odpowiednich Ĩródeá energii elektrycznej oraz ciĞnienia. Pierwsze czynnoĞci obsáugowe: (1) NaleĪy powoli wáączyü przepáyw w instalacji. NastĊpnie powoli otworzyü zawory robocze tak, aby uniknąü wahaĔ przepáywu. (2) NaleĪy teraz sprawdziü, czy nie wystĊpują nieszczelnoĞci przy podáączeniach wejĞciowym i wyjĞciowym miernika przepáywu. JeĪeli nie ma Īadnych nieszczelnoĞci, moĪna zwiĊkszyü ciĞnienie w instalacji do wartoĞci ciĞnienia roboczego. Przed przystąpieniem do czynnoĞci serwisowych naleĪy upewniü siĊ, Īe ciĞnienie robocze jest odáączone. JeĪeli konieczna jest wymiana czĊĞci zamiennych, naleĪy zawsze stosowaü czĊĞci zamienne specyfikowane przez firmĊ Brooks Instrument a czynnoĞci ich wymiany powinien w kaĪdym przypadku dokonywaü przeszkolony personel. Stosowanie nieautoryzowanych czĊĞci i procedur serwisowych moĪe niekorzystnie wpáynąü na dziaáanie produktu oraz zagroziü bezpieczeĔstwu instalacji. Korzystanie z podobnie wyglądających zamienników moĪe doprowadziü do poĪaru, poraĪenia prądem lub nieprawidáowego dziaáania urządzenia. NaleĪy upewniü siĊ, Īe wszystkie otwory urządzenia są zamkniĊte a osáony umocowane na swoich miejscach, aby zapobiec obraĪeniom ciaáa lub poraĪeniu prądem personelu. Zalecenie to nie dotyczy przeszkolonego pracownika wykonującego prace serwisowe lub konserwacyjne. OSTRZEĩENIE: W przypadku mierników przepáywu cieczy, jeĪeli znajdujące siĊ na nich zawory wejĞciowe i wyjĞciowe mają byü z jakiegoĞ powodu zamkniĊte, to urządzenie musi zostaü caákowicie opróĪnione z ciekáego medium. Niedopeánienie tego zalecenia moĪe doprowadziü do termicznego zwiĊkszenia objĊtoĞci cieczy, co z kolei moĪe spowodowaü uszkodzenie urządzenia i obraĪenia personelu. Europejska dyrektywa dotycząca urządzeĔ ciĞnieniowych (PED) Wszystkie urządzenia ciĞnieniowe pracujące przy ciĞnieniu wewnĊtrznym wzglĊdnym wiĊkszym niĪ 0.5 bara i wielkoĞci powyĪej 25 mm lub 1 cala podlegają dyrektywie europejskiej dotyczącej urządzeĔ ciĞnieniowych (PED). x Rozdziaá „Specyfikacja techniczna” niniejszej instrukcji zawiera zalecenia dotyczące dyrektywy PED. x Mierniki opisane w tej instrukcji są zgodne z dyrektywą EN 97/23/EC. x Wszystkie mierniki przepáywu firmy Brooks Instrument naleĪą do 1-szej grupy cieczy. x Urządzenia pomiarowe o wielkoĞci powyĪej 25 mm lub 1 cala naleĪą do kategorii I, II lub III dyrektywy PED. x Urządzenia pomiarowe o wielkoĞci 25 mm lub 1 cala lub mniejsze podlegają zaleceniom „Uznanej Praktyki InĪynierskiej” (SEP). Europejska dyrektywa dotycząca kompatybilnoĞci elektromagnetycznej (EMC) Urządzenia elektryczne / elektroniczne firmy Brooks Instrument posiadające oznaczenie CE, przeszáy pozytywnie testy pod kątem speániania przez nich wymogów kompatybilnoĞci elektromagnetycznej (Dyrektywa EMC 2004/108/EC). JednakĪe szczególną uwagĊ naleĪy poĞwiĊciü przy doborze przewodów sygnaáowych, które mają byü stosowane z urządzeniami ze znakiem CE. JakoĞü przewodu sygnaáowego, dáawic oraz záączy przewodu: Firma Brooks Instrument dostarcza wysokiej jakoĞci przewody, które speániają wymagania zawarte w specyfikacji dla certyfikatu CE. JeĪeli stosuje siĊ wáasne przewody sygnaáowe, to powinny one byü w caáoĞci w peáni ekranowane. Záącza typu „D” lub okrągáe powinny zawieraü metalowy ekran. JeĞli to moĪliwe, naleĪy stosowaü metalowe dáawice przewodu zapewniające mocowanie jego ekranu. Ekran przewodu powinien byü poáączony z metalową osáoną lub dáawicą zapewniając caákowite, dookólne ekranowanie na obu koĔcach przewodu. Ekran przewodu powinien byü uziemiony. Záącza krawĊdziowe są standardowo niemetaliczne. Stosowane przewody muszą byü w peáni ekranowane zgodnie z certyfikatem CE. Ekran przewodu powinien byü uziemiony. Konfiguracja styków jest podana w niniejszej instrukcji obsáugi. Wyáadowania elektrostatyczne (ESD) UWAGA: Urządzenie zawiera czĊĞci elektroniczne podatne na uszkodzenia spowodowane áadunkami elektrostatycznymi. Przy obchodzeniu siĊ z wewnĊtrznymi podzespoáami i czĊĞciami elektronicznymi naleĪy przestrzegaü nastĊpujących zasad postĊpowania: 1. NaleĪy odáączyü zasilanie od urządzenia. 2. Osoba wykonująca czynnoĞci musi zostaü uziemiona za pomocą opaski na przegubie dáoni lub w inny, bezpieczny sposób, zanim przystąpi do instalacji, wyjĊcia lub regulacji obwodów drukowanych lub innych wewnĊtrznych podzespoáów elektronicznych urządzenia. 3. Obwody drukowane naleĪy transportowaü w przewodzącym pojemniku. Páytki drukowane naleĪy wyjmowaü z opakowania ochronnego bezpoĞrednio przed ich montaĪem. Wymontowane páytki naleĪy niezwáocznie umieĞciü w opakowaniu ochronnym sáuĪącym do transportowania, skáadowania lub odsyáania do producenta. Uwagi: Fakt, Īe urządzenie zawiera czĊĞci nieodporne na wyáadowania elektrostatyczne (ESD) jest rzeczą normalną. WiĊkszoĞü nowoczesnych urządzeĔ elektronicznych zawiera komponenty wykonane w technologii tlenków metali (NMOS, SMOS itp.). Jak pokazuje praktyka, nawet niewielkie wyáadowanie elektrostatyczne moĪe uszkodziü lub zniszczyü takie urządzenie. Uszkodzone czĊĞci, nawet jeĪeli na pozór dziaáają poprawnie, szybko doprowadzają do nieprawidáowej pracy urządzenia. A-14 Section A - Essential Instructions Installation and Operation Manual X-VA-FC-eng Part Number: 541B045AAG December, 2015 Flow Controllers for Gas and Liquid Service Portuguese Instruções Básicas Ler antes de proceder! A Brooks Instrument projecta, fabrica e testa os seus produtos de forma a satisfazer numerosas normas nacionais e internacionais. Estes equipamentos devem ser instalados, utilizados e mantidos de forma adequada, e devem funcionar dentro da sua gama de utilização. As instruções seguintes devem ser, durante a instalação, uso e/ou manutenção dos equipamentos da Brooks Instrument, apreendidas e integradas no plano de protecção e segurança no trabalho. x Para assegurar o desempenho adequado, a instalação, exploração, actualização e/ou manutenção do equipamento deve ser realizada, exclusivamente, por pessoal qualificado. x Antes de instalar, utilizar e/ou executar operações de manutenção devem ser lidas todas as instruções do equipamento. No caso do presente manual não ser apropriado procure, na capa traseira, o distribuidor mais próximo e contacte-o para obter informações adicionais. Guarde este manual para futura referência. ATENÇÃO: não sujeite o equipamento a condições fora das gamas de serviços indicadas. Ao não respeitar esta advertência poderá provocar avarias no equipamento e/ou danos pessoais. x Se as instruções deste manual não estiverem suficientemente claras, contacte o representante Brooks Instrument para esclarecer as suas dúvidas. x Tenha sempre presente todas as advertências, apelos e instruções indicadas no equipamento e/ou fornecidas junto com o mesmo. x A instalação do equipamento deverá ser efectuada cumprindo todas as instruções indicadas no manual assim como as normas e regulamentos locais e nacionais vigentes. Ligue o equipamento exclusivamente a fontes de energia eléctrica e/ou pneumática adequadas. x Procedimento: (1) Pressurize lentamente o sistema. Abra lentamente as válvulas para evitar variações bruscas de caudal. (2) Verifique se há fugas nas ligações de entrada e saída do medidor de caudal. Se não detectar fugas, poderá colocar o sistema à pressão de trabalho. x Antes de efectuar qualquer operação de manutenção verifique sempre a possibilidade do equipamento estar sob pressão. No caso de ser preciso substituir peças, estas devem ser as recomendadas pela Brooks Instrument e o trabalho de substituição deverá ser efectuado por técnicos qualificados. Procedimentos e peças não conformes poderão alterar o desempenho do equipamento, danificá-lo ou colocar em risco a sua segurança ou de outros. Substituir peças por outras não originais, meramente semelhantes, poderá originar choques eléctricos, fogo ou em funcionamento inadequado. x Deverá manter o equipamento intacto e fechado, verificando se as coberturas de protecção estão nos seus lugares devidos, de forma a evitar choques eléctricos e/ou danos pessoais, excepto no caso de se tratar de um técnico qualificado e se estiver a executar trabalhos de manutenção. ATENÇÃO: Se por qualquer razão for necessário fechar as válvulas a montante e jusante do equipamento, tenha em atenção que o mesmo deverá ser previamente esvaziado do fluído que o atravessa. Esta obrigação surge do facto de existir a possibilidade de ocorrer dilatação térmica do líquido, no interior do aparelho, podendo provocar danos pessoais ou materiais graves. Directiva Europeia para equipamentos sob pressão (PED) Todos os equipamentos sujeitos a pressão interior superior a 0,5 bar (g) e com calibre superior a 25 mm (1 polegada) estão sob a vigência da directiva europeia de equipamentos sob pressão (PED). x O capítulo "Dados técnicos" do manual contém instruções relativas à Directiva PED. x O caudalímetro objecto deste manual satisfaz a directiva 97/23/CE da UE. x Os caudalímetros Brooks pertencem ao grupo 1 de fluidos. x Os caudalímetros com calibre superior a 25 mm (1 polegada) pertencem às categorias PED I, II, ou III. x Os caudalímetros de 25 mm (1 polegada) ou menores seguem as “Boas regras de engenharia” (SEP). Directiva Europeia sobre Compatibilidade electromagnética (EMC) Os equipamentos (eléctricos/electrónicos) da Brooks Instrument que têm a marcação CE passaram os testes comprovativos dos requisitos de compatibilidade electromagnética (Directiva EMC número 2004/108/EC). Todavia, ao utilizar os aparelhos compete-lhe a escolha dos cabos de sinal adequados para os equipamentos com marcação CE. Qualidade dos cabos de sinal, bucins e conectores: A Brooks Instrument fornece cabos de alta qualidade que cumprem todos os requisitos da marcação CE. No caso de utilizar os seus próprios cabos de sinal, assegure uma blindagem a 100%. Os conectores do tipo “D” ou "circular" têm que ser blindados por uma malha metálica. Se precisar de usar bucins, estes têm que permitir a crimpagem da malha/blindagem do cabo. A blindagem do cabo deve ser ligada ao corpo metálico ou bocal e assegurando a blindagem em 360°. A blindagem deve terminar numa ligação à terra. Os conectores ligados a cartões serão, em geral, não-metálicos. Os cabos utilizados devem ter fita de blindagem a 100% para satisfazer a marcação CE. A blindagem, deverá terminar numa ligação à terra. Atribuição de pinos: Veja as instruções de operação anexas. Descarga Electrostática (ESD) ATENÇÃO: Alguns componentes deste equipamento são susceptíveis à acção da electricidade estática, podendo ficar danificados. Ao remover, colocar ou manipular placas de circuitos electrónicos deverá ter em atenção os seguintes procedimentos: 1. Desligar o equipamento da rede. 2. O utilizador, antes de qualquer intervenção que envolva os cartões de circuitos ou outros dispositivos internos, terá que se ligar à terra por meio duma bracelete de pulso ou outro dispositivo adequado. 3. Os circuitos impressos deverão ser transportados numa embalagem condutiva. Os cartões só deverão ser retirados da embalagem protectora imediatamente antes da sua inserção. O cartão retirado deverá ser recolocado imediatamente na embalagem protectora que servirá para o seu transporte, armazenagem ou retorno a fábrica. Observações: Tenha presente que este equipamento poderá não ser o único objecto capaz de ser portador de peças sensíveis a descargas electrostáticas (ESD). Na maioria dos dispositivos electrónicos Brooks encontram-se peças de tecnologia de óxidos metálicos (NMOS, SMOS, etc.). A experiência mostra que até pequenas quantidades de electricidade estática são capazes de danificar ou destruir esses dispositivos. Os componentes danificados, embora inicialmente funcionem aparentemente bem, acabam por ter falhas prematuramente. A-15 Section A - Essential Instructions Installation and Operation Manual Flow Controllers for Gas and Liquid Service X-VA-FC-eng Part Number: 541B045AAG December, 2015 Romanian IndicaĠii de referinĠă CitiĠi-le întâi pe acestea! Brooks Instrument îúi proiectează, produce úi testează produsele într-un mod ce respectă un mare număr de standarde autohtone úi internaĠionale. Aceste instalaĠii trebuie amplasate, exploatate úi întreĠinute corespunzător, pentru ca în toate situaĠiile, domeniul lor de lucru să corespundă operării normale. În ceea ce priveúte instalarea, operarea úi întreĠinerea produselor Brooks Instrument, indicaĠiile de mai jos trebuie respectate úi trebuie introduse in programul de protecĠia muncii. x Pentru garantarea prestaĠiei corecte, instalarea, operarea, actualizarea, programarea úi întreĠinerea produsului poate fi realizată doar de către personal calificat. x InstrucĠiunile de instalare ale produsului trebuie citite integral, înainte de punerea în serviciu úi exploatarea sa. În măsura în care ediĠia acestui manual nu este cea adecvată, identificaĠi pe ultima copertă coordonatele distribuitorului local úi pentru lămuriri suplimentare adresaĠi-vă acestuia. PăstraĠi acest manual pentru referinĠe ulterioare. ATENğIE: Nu utilizaĠi instalaĠia în afara intervalului de funcĠionare indicat în instrucĠiunile de operare. Nerespectarea acestui lucru se poate solda cu răniri grave de persoane sau defectarea instalaĠiei. x În măsura în care indicaĠiile cărĠii maúinii nu sunt suficient de lămuritoare, luaĠi legătura cu reprezentantul Brooks Instrument pentru clarificarea problemei. x PăstraĠi toate avertismentele, avizele úi instrucĠiunile livrate odată cu instalaĠia sau inscripĠionate pe aceasta. x EfectuaĠi instalarea echipamentului în conformitate cu indicaĠiile de instalare corespunzătoare, respectiv cu respectarea prevederilor naĠionale. Echipamentul se conectează exclusiv la surse de energie electrică úi de presiune corespunzătoare. x Succesiune: (1) PresurizaĠi lent instalaĠia. DeschideĠi încetul cu încetul supapa de funcĠionare pentru evitarea fluctuaĠiilor de flux. (2) ControlaĠi dacă nu sunt prelingeri la intrarea sau ieúirea debitmetrului de branúare. Dacă nu sunt scurgeri, presurizaĠi instalaĠia la presiunea de lucru. x Înaintea exploatării/ întreĠinerii, verificaĠi neapărat dacă conducta uzinală nu este sub presiune. În măsura în care este nevoie de piese de schimb, este neapărat necesar ca manevrarea pieselor de schimb să fie făcută de personal cu calificare profesională agreat de Brooks Instrument. Utilizarea altor piese de schimb decât cele originale úi licenĠiate poate avea efecte asupra performanĠelor instalaĠiei úi asupra siguranĠei sale în exploatare. Utilizarea de piese asemănătoare de substituire poate avea ca rezultat pericol de incendiu úi electrocutare. x În toate cazurile toate uúile instalaĠiei trebuie să fie închise, cuútile de protecĠie să fie puse la locurile lor, pentru evitarea electrocutării úi rănirii de persoane, exceptând situaĠiile când un specialist efectuează lucrări de întreĠinere. ATENğIE: În cazul instalaĠiilor cu flux de fluide, dacă din orice motiv este necesară închiderea valvelor de intrare úi ieúire, limitrofe instalaĠiei, instalaĠia trebuie complet golită. Neglijarea acestui lucru poate avea ca efect dilatarea termică a fluidului, care poate defecta instalaĠia úi poate produce răniri de persoane. Directiva europeană pentru instalaĠiile sub presiune (PED) Toate instalaĠiile úi sistemele presurizate ce se află sub presiuni interne ce depăúesc 0,5 mbar (g) úi au mai mult de 25 mm sau 1 Ġol, cad sub incidenĠa normei europene corespunzătoare (PED). x La capitolul "Date tehnice" din cartea maúinii se găsesc indicaĠiile corespunzătoare directivei PED. x Mijloacele de măsurare menĠionate în cartea maúinii corespund directivei 97/23/EK EU. x Toate debitmetrele Brooks corespund clasei 1 de fluide. x Mijloacele de măsurare mai mari de 25 mm sau 1 Ġol corespund categoriei PED I, II sau III. x Mijloacele de măsurare mai mici de 25 mm sau 1 Ġol se conformează practicii inginereúti acceptate (SEP). Directiva europeană privitoare la compatibilitatea electromagnetică (EMC). InstalaĠiile (electrice /electronice) ce poartă marca Brooks Instrument CE îndeplinesc cu succes cerinĠele testelor de verificare ale compatibilităĠii electromagnetice (Cf. directivelor europene EMC cu nr. 2004/108/EC). În acelaúi timp trebuie acordată o atenĠie deosebită la alegerea cablurilor de semnalizare utilizate pentru instalaĠiile ce poartă marcajul CE. Calitatea cablurilor de semnalizare, a legăturilor prin cablu úi a conectoarelor: Brooks Instrument oferă cabluri de calitate ridicată, care corespund cerinĠelor calitative ale CE. În măsura în care folosiĠi cabluri proprii, trebuie alese acelea care sunt 100% ecranate úi prevăzute cu filtre. Conectoarele „D” sau cele „circulare” trebuie sa dispună de ecrane metalice. În caz de nevoie trebuie folosite conectoare metalice pentru montarea filtrelor de cablu. Filtrul de cablu trebuie conectat la carcasa metalică sau manúon úi în ambele cazuri trebuie asigurată ecranarea la 360°. Ecranarea trebuie terminată cu o legare la pământ. Conform standardului, conectoarele aparĠinând plăcilor electronice nu sunt metalice. Cablurile folosite trebuie să fie 100% ecranate úi prevăzute cu filtre pentru a corespunde clasificării CE. Ecranarea trebuie terminată cu o legare la pământ. ConfiguraĠie de contact: Vezi instrucĠiunile de operare ataúate. Descărcare electrostatică (ESD) ATENğIE: InstalaĠia include piese care sunt predispuse la defectare sub influenĠa electricităĠii statice. Trebuie respectate metodele corespunzătoare de extragere, instalare sau alte manipulări ale circuitelor electronice. Procedură de manipulare: 1. InstalaĠia trebuie scoasă de sub tensiune. 2. Înaintea de inserarea, scoaterea sau reglarea vreunei cartele electronice, sau a altui dispozitiv intern, persoana trebuie să se lege la pământ cu banda pentru articulaĠia mâinii sau alte dispozitive de siguranĠă disponibile pentru acest scop. 3. Cartelele cu cablaje electronice imprimate trebuie transportate în ambalaje anti-electrostatice (conductoare). Cartelele se pot scoate din ambalaj, doar nemijlocit înaintea amplasării lor. Cartela demontată trebuie pusă neîntârziat în ambalajul de protecĠie în vederea transportării, a depozitării sau returnării la producător. ObservaĠii: În echipamente se găsesc adesea componente sensibile la descărcare electrostatică (ESD). Majoritatea echipamentelor moderne includ componente electronice realizate în tehnologie metal-oxid semiconductor (NMOS, SMOS, etc.) ExperienĠa a dovedit că acestea pot fi afectate sau deteriorate chiar de energii electrostatice de slabă intensitate. Componentele defectate, cu toate că în aparenĠă sunt funcĠionale, duc în timp la defecĠiuni incipiente. A-16 Installation and Operation Manual X-VA-FC-eng Part Number: 541B045AAG December, 2015 Section A - Essential Instructions Flow Controllers for Gas and Liquid Service Slovak Základné príkazy PreþítaĢ pred inštaláciou! Brooks Instrument svoje výrobky projektuje, vyrába a testuje takým spôsobom, aby tieto vyhoveli domácim aj medzinárodným normám. Tieto zariadenia je potrebné predpísaným spôsobom inštalovaĢ, prevádzkovaĢ a udržiavaĢ, na zabezpeþenie ich spoĐahlivej a normálnej prevádzky v celom pracovnom rozsahu. Nižšie uvedené príkazy je potrebné dodržiavaĢ a zaþleniĢ do programu bezpeþnostných predpisov v priebehu inštalácie, prevádzky a údržby výrobkov Brooks Instruments. • V záujme zabezpeþenia vyhovujúceho výkonu inštaláciu, prevádzku, programovanie, aktualizáciu a údržbu zariadení má vykonávaĢ výluþne odborne kvalifikovaný personál. • Pred inštaláciou, prevádzkou a servisu zariadení je potrebné preþítaĢ všetky príkazy. Ak táto príruþka nie je správna, tak na zadnej strane treba nájsĢ miestneho distribútora, kontaktovaĢ ho pre ćalšie informácie. Pre neskoršie informácie uschovajte príruþku. UPOZORNENIE: NeprevádzkovaĢ zariadenie v rozsahu mimo rozsahu uvedenom v prevádzkovej príruþke. Porušenie tohto oznámenia môže maĢ za následok Ģažkú ujmu na zdraví a vedie k poškodeniu zariadenia. x Ak príkazy v návode nie sú jednoznaþné, kontaktujte zástupcu Brooks Instrument na objasnenie problémov. x Dodržujte všetky upozornenia, príkazy a usmernenia uvedené na zariadení, alebo s ním dodané. x Zariadenia inštalujte podĐa návodu uvedeného v príkaze na inštaláciu, v súlade s miestnymi a národnými predpismi. Zariadenie pripojte výluþne len na vyhovujúci elektrický a tlakový zdroj x Postup: (1) Pomaly natlakujte systém. Prevádzkový ventil otvorte pomaly na zamedzenie kolísania prietoku. (2) Prekontrolujte tesnosĢ vstupného a výstupného zapojenia prietokomeru. Keć nie je presakovanie, spoje sú tesné, naplniĢ systém na prevádzkový tlak. x Pred vykonávaním servisných prác kontrolovaĢ, þi systém nie je pod tlakom. V prípade, že je potrebná výmena súþiastky, výmenu dielov, urþených Brooks Instrument musí vykonaĢ kvalifikovaná osoba. Použitie nepovolených dielov a vykonávanie nepovolených aktivít ohrozujú bezpeþnosĢ prevádzvky a majú negatívny vplyv na výkon zariadenia. Nahradenie súþiastok len podobnými komponentmi môže maĢ za následok požiar, úraz elektrickým prúdom alebo nedostatoþnú funkciu zariadenia x Všetky ochranné kryty, dvierka zariadenia majú byĢ zatvorené na zabezpeþenie ochrany proti úrazu elektrickým prúdom a proti poraneniam obsluhy. Výnimku tvorí vykonávanie údržby kvalifikovaným odborníkom. UPOZORNENIE: Pri zariadeniach s prietokom kvapalín, keć z akéhokoĐvek dôvodu je nutné uzavrieĢ vstupné a výstupné ventily, zariadenie je potrebné úplne vyprázdniĢ. Zanedbanie vypúšĢania má za následok poškodenie zariadenia s možnosĢou zranenia obsluhy z dôvodu tepelnej rozĢažnosti náplne. Európska smernica vzĢahujúca sa na tlakové zariadenia (PED) x x x x x x Všetky zariadenia s vyšším vnútorným pretlakom ako 0,5 bar (g), a väþšieho rozmeru ako 25 mm alebo 1 anglický palec, podliehajú pod Európsku smernicu vzĢahujúcu sa na tlakové nádoby (PED). Kapitola "Technické údaje" návodu na obsluhu obsahuje príkazy vzĢahujúce sa na smernicu PED. Meracie prostriedky uvedené v návode na obsluhu vyhovujú smernici 97/23/ES EÚ. Všetky prietokomery Brooks patria do 1. skupiny kvapalín. Meracie prístroje presahujúce rozmery 25 mm alebo 1 " spĎĖajú I., II., alebo III. kategóriu PED. Meracie prístroje menšie alebo rovné ako 25 mm alebo 1 " zodpovedajú zaužívanej meracej praxi (SEP). Európska smernica vzĢahujúca sa na elektromagnetickú kompatibilitu (EMC) Elektrické / elektronické zariadenia Brooks Instrument, ktoré si zaslúžili znaþku CE, úspešne splnili skúšobné testy požiadaviek elektromagnetickej kompatibility (smernica EMC þ. 2004/108/EC). Pritom treba venovaĢ zvláštnu starostlivosĢ na výber signálnych káblov zariadenia, s oznaþením CE. Kvalita signálnych káblov, káblových spojov a prípojov: Brooks Instrument ponúka vysoko kvalitné káble, ktoré spĎĖajú požiadavky kvalitatívneho zaradenia CE. Ak použijete vlastné signálne káble, majú maĢ 100%-né tienenie, s plným filtrovaním. Prípojky "kruhové" alebo tvaru "D" majú maĢ kovové tienenie. V prípade potreby treba použiĢ kovové káblové spojky k upevneniu káblového filtra. Káblový filter treba pripojiĢ ku kovovému telesu alebo k puzdru, na oboch stranách zabezpeþiĢ tienenie v kruhu 360 °. Tienenie má byĢ ukonþené uzemnením. Prípojky vedúce ku kartám podĐa noriem sú nekovové. Použité káble, pre vyhovenie predpisom CE musia maĢ 100%-né filtrovanie tienením. Tienenie má byĢ ukonþené uzemnením. Konfigurácia kontaktov: Vić priložený návod na obsluhu. . Elektrostatický výboj (ESD) UPOZORNENIE: Prístroj obsahuje súþiastky, ktoré môžu byĢ poškodené od elektrostatických nábojov. Pri montáži, odstraĖovaní alebo inej údržby vnútorných obvodových kariet je potrebné dodržiavaĢ príslušné postupy. Postup ošetrovania: 1. Zariadenie odpojiĢ od napájania. 2. Osoba vykonávajúca údržbu má byĢ uzemnená uzemĖujúcim náramkom, alebo iným, na túto prácu vyhovujúcim spôsobom pred vykonávaním inštalácie, demontáže a nastavenia obvodových kariet alebo iného vnútorného prostriedku. 3. Karty obvodov sa musia prepravovaĢ v elektricky vodivom balení. Karty sa môžu vyberaĢ z ochranného obalu výluþne len tesne pred montážou, zasunutím! Vybranú kartu okamžite treba umiestniĢ do ochranného obalu, urþeného pre dopravu, skladovanie, alebo pre spätnú prepravu do výrobného závodu. Poznámky: Existencia prvkov, ktoré sú citlivé na elektrostatické výboje (ESD) v prístroji je þastým javom. U väþšiny moderných elektronických prostriedkov sú použité prvky s technológiou oxidu kovov (NMOS, SMOS, atć.). Skúsenosti dokazujú, že aj nepatrné elektrostatické výboje poškodzujú, zniþia tieto prostriedky. Poškodené súþiastky, aj keć zdanlivo pracujú bez chyby, odkazujú na vznikajúce poruchy. A-17 Section A - Essential Instructions Installation and Operation Manual Flow Controllers for Gas and Liquid Service X-VA-FC-eng Part Number: 541B045AAG December, 2015 Slovene Osnovna navodila Najprej preberite jih Brooks Instrument tako konstruira, izdeluje in terstira svoje izdelke, da oni ustrezajo številnim domaþim in mednarodnim standardom. Te naprave se morajo ustrezno instalirati, koristiti in vzdrževati, da vsekakor delajo ustrezno normalnom podroþju funkcioniranja. Naslednjih navodil se mora držati in potrebno je vgraditi v program varstva pri delu pri instaliranju, korišþenju in vzdržavanju izdelkov proizvajalca Brooks Instrument. x Za jemstvo ustreznega uþinka naj izkljuþno strokovno osobje opravlja instaliranje, korišþenje, osveženje, programiranje in vzdrževanje izdelka. x Potrebno je prebrati vsa navodila pred instaliranjem, korišþenjem in servisiranjem izdelka. V kolikor ta priroþnik ni ustrezna publikacija, na zadnji strani poišþite lokalnega distributerja in za nadaljnje informacije stopite z njim v kontakt. Prihranite ta priroþnik za poznejše informacije. OPOMBA: Ne koristite napravo izven podroþja iz navodila za uporabo. Prekršek tega lahko privede do osebnih poškodb ali okvare naprave. x V kolikor navodila priroþnika niso enosmiselna, stopite v kontakt z zastopnikom društva Brooks Instrument, da razþistite problem. x Držite se vseh opozoril, povabil, navodil, ki so navedena na napravi ali skupaj z njim izporoþena. x Napravo instalirajte shodno navodilom in relevantnim lokalnim in nacionalnim navodilom iz navodila za instalirenje.. Izdelek spojite izkljuþno na ustrezni izvir elektrike in obskrbo tlaka. x Proces: (1) Poþasi položite sistem pod tlak. Poþasi odpirajte pogonske ventile zaradi izogibanja nihanju pretoka. (2) Preverjajte, ima li curljanja pri povezu vstopa in izstopa merilca toka. ýe ni curljanja, naplonite sistem na pogonski tlak. x Pred servisom vsekakor preverjajte, ali je pogonski vod pod tlakom. ýe je potreben rezervni del, svekakor strokovna oseba mora rokovati z rezervnimi deli odrejenimi od Brooks Instrument. Nedovoljeni rezervni deli in dejavnosti lahko vplivajo na uþinek izdelka, oziroma ugrožavajo varnostni pogon. Sprememba samo z podobnimi rezervnimi deli lahko ima za posledico požar, nevarnost elektiþnega šoka ali nedovoljno funkcioniranje. x Vsa vrata naprave svekakor morajo biti zaprta, zašþitni ovitki morajo biti na svojem mestu zaradi izogibanja šoku in osebnim poškodbam, razen, þe na njej strokovnjak opravlja dela vzdrževanja. OPOMBA: V primeru naprave za tok tekoþine, þe je iz katera koli razloga potrebno zapreti vstopne in izstopne ventile pri napravi, naprava se mora celotno izprazniti. Zamuda tega lahko provzroþi toplotno proširjenje tekoþine, kar poškoduje napravo in lahko povrzoþi osebno poškodbo. Europske smernice za naprave ohranjanja pritiska (PED) Vsaka naprava ohranjanja pritiska z notranjim pritiskom veþ od 0,5 bara (g) in veþjim od 25 mm ali 1 palca sodi pod Europskim smernicam za ohranjanje pritiska (PED). x Poglavje priroþnika „Tehniþni podatki” vsebuje navodila, ki se nanašajo na smernice PED. x Merilni instrumenti navajani v priroþniku ustrezajo smernicam EU številke 97/23/EK x Vsaki merilec pretoka Brooks sodi v skupino tekoþin številke 1. x Merilni instrumenti veþji od 25 mm ali 1 palca ustrezajo kategriji PED I, II, ali III. x Merilni instrumenti manjši od 25 mm oziroma 1 palca ali manjši sledijo sprejeti inženjeski praksi (SEP). Evropska smernica za Elektromagnetno kompatibilnost (EMC) Naprave Brooks Instrument, ki so zaslužile CE oznaþbo (elektriþni/elektronski) so uspešno izpolnile testove zahteve o elektromangnetni kompatibilnosti (št. 2004/108/EC smernice EMC) . Obenem mora se posebno pozornost posvetiti na izbiro signalnega kabla, ki se uporabljajo za naprave z oznaþbo CE. Kakaovost signalnih kablov, povezav kablov, prikljuþkov: Brooks Insturment nuja kabele visoke kakovosti, ki ustrezajo zahtevam kvalificiranja CE. V kolikor se uporbalja lastni signalni kabel, treba je izbrati, ki za 100 % senco v polni meri filtriran. Prikljuþki „D” „olika kroga” morajo biti zasenþeni kovonskom sencom. ýe bo potrebno, uporabite kovinske povezave za pritrditev filtra kabla Filtar kabla je treba prikljuþiti na kovinsko ohišje ali plašt in na obe polovici je treba senþiti v 360°. Senþenje mora završiti v ozemljitvi. Prikljuþki, ki sodijo karitcam normalno nisu kovinskik. Korišþeni kabli moraju biti filtrirani s 100 % senco, da odgovarjajo CE kvalifikaciji. Sencanje mora imat konec v ozemljitvi. Konfiguracija stika: Vidi priloženo navodilo za uporabo. Elektrostatiþno izpražnjenje (ESD) OPOZORILO: Naprava vsebuje take sestavne dele, ki so naklonjeni k poškodbi od statiþne elektrike. Treba se je držati ustreznih postopkov pri odstranjevanju, vlogu ali drugega rokovanja kartic in sredstev notranjih tokovnih krogov. Posotpek rokovanja: 1. napravo je treba izklopiti iz elektriþnega toka. 2. Osebo je treba ozemljiti zapestnim pašþekom ali z drugim varnostnim in za ta namen primernim sredstvom preden bi instalirala, jemala, ali nastavila kartico za tokovni krog ali drugo notranjo opremo. 3. Tiskane kartice tokovnega kroga je treba izporoþiti v konduktivni embalaži. Karte so odstranjive izkljuþno neposredno pred vlogom iz zašþitne embalaže ven. Izjemljeno kartico nemudoma staviti v zašþitno embalažo za gibanje, skladišþenje ali pošiljanje nazaj. Opombe: Nije poseben pojav, da se v napravi nahajajo obþutljivi sestavni deli na elektrostatiþno pražnjenje (ESD). V veüem delu modernih elektronskih sredstev nahajajo se sestavni deli na kovinsko oksidno tehnologijo (NMOS, SMOS itd..). Izkustva potrjujejo, da majhna statiþna elektrika more poškodovati ali uniþiti ta sredstva. Oškodovani rezervni deli, þe na videz dobro delajo, nakažejo zaþetno napako. A-18 Section A - Essential Instructions Installation and Operation Manual X-VA-FC-eng Part Number: 541B045AAG December, 2015 Flow Controllers for Gas and Liquid Service Spanish Instrucciones básicas ¡Léalos primero! El Brooks Instrument proyecta, fabrica y prueba sus productos de manera que éstos respondan a numerosas normas nacionales e internacionales. Dichas instalaciones deben ser emplazadas, operadas y mantenidas adecuadamente, para que puedan marchar de todas formas en conformidad con el alcance normal de funcionamiento. Las siguientes instrucciones deben cumplirse y incorporadas en su programa de seguridad cuando instalando, operando y mantenimiento los productos Brooks Instrument. x Para asegurar el adecuado rendimiento, para instalar, operar, actualizar, programar y mantener tiene que realizarse exclusivamente por una persona calificada. x Antes de la instalación, operación y servicio del producto leer todas las respectivas instrucciones. Si el presente manual no es la adecuada publicación, busque al distribuidor local que figura en la contraportada y póngase en contacto con él para obtener informaciones. Guarde el presente manual para tener informaciones también en el futuro. ATENCIÓN: No haga funcionar los equipos fuera del rango indicado en las instrucciones de funcionamiento. El incumplimiento de estas últimas puede conducir a graves daños personales o a la avería del equipo. x Si las instrucciones del manual no son evidentes, póngase en contacto con el representante de Brooks Instrument para aclarar el problema x Observar todas las alertas, advertencias e instrucciones indicadas en el equipo o suministradas con el mismo. x Instale su equipo en conformidad con las recomendaciones indicadas en las respectivas instrucciones de instalación y con las pautas de las normas vigentes locales e internacionales. Conectar el producto exclusivamente a la adecuada fuente eléctrica y presión. x Proceso: (1) Colocar lentamente flujo en el sistema. Abrir lentamente las válvulas de proceso para evitar oscilación del flujo. (2) Verificar si hay fuga alrededor de las conexiones de entrada y salida del flujómetro, Si no hay, llenar el sistema con la presión de operación. x Antes de efectuar el servicio, verificar si hay presión o no en la tubería de la red. Si se requiere realizar un recambio de piezas, solamente el personal calificado puede manipular las piezas de repuesto determinadas por Brooks Instrument Las piezas y operaciones no autorizadas pueden afectar el rendimiento del producto o arriesgar el funcionamiento seguro. El recambio realizado con piezas sólo similares pueden traer como consecuencias incendios, choques eléctricos o funcionamiento bajo. x Todas las puertas de la instalación deben estar cerradas, las cubiertas de protección tienen que hallarse en el debido sitio con el fin de evitar los daños personales y los choques eléctricos, salvo cuando un especialista efectúa el mantenimiento. ADVERTENCIA: En caso de instalaciones que circulen líquido, si por cualquier razón se hubiera de cerrar las válvulas de entrada y salida situadas al lado del equipo, dichas instalaciones deberán ser completamente vaciadas. La omisión de esto último puede provocar la dilatación térmica del líquido, lo que puede dañar al equipo y conducir a daños personales. Directriz Europea de los Equipos de Presión (PED) Todos los equipos de presión, con una presión interna que supere a 0,5 bar (g) con tamaño mayor a 25 mm o 1 pulgada entran el ámbito de la Directriz Europea de los Equipos de Presión (PED). x El capítulo Datos Técnicos del manual incluye las instrucciones respecto a las directivas de PED x Los instrumentos de medición indicados en el Manual responden a las EN directivas 97/23/EC. x Todos los flujómetros Brooks pertenecen a la categoría 1 del grupo de fluidos. x Los instrumentos de medición más grandes que 25 mm o 1 pulgada están en conformidad con las categorías I, II o III de PED x Los instrumentos de medición más pequeños que 25 mm o 1 pulgada siguen la Práctica Aceptada de Ingeniería (SEP). Directriz Europea respecto a la Compatibilidad Electromagnética (EMC) Las instalaciones de Brooks Instrument (eléctricas/electrónicas) merecedores de la categoría CE cumplieron con éxito las pruebas que verifican las exigencias de la compatibilidad electromagnética (directiva de EMC 2004/108/EC). Al mismo tiempo se ha de prestar una especial atención en la selección de los cables de señal, utilizados con los equipos marcados con CE. Calidad de los cables de señal, piezas de unión de cable y conectores: El Brooks Instrument ofrece cables de alta calidad, que responden a los requerimientos de calificación CE. Si se utiliza cable propio de la firma, se ha de elegir uno que sea completamente filtrado con blindaje de 100%. Las piezas de unión de forma „D” o „circular” deben ser blindadas mediante blindaje metálica. Si es necesario, aplicar piezas de unión de metal para sujetar el filtro de cable. Conectar el filtro de cable a la caja o manguito de metal blindándolo en ambas caras en 360°. El blindaje debe terminar en tierra. Los conectores que pertenecen a las tarjetas normalmente no son metalizados. Los cables utilizados deben ser filtrados con una blindaje de 100% para responder a la calificación CE. El blindaje debe terminarse en tierra. Configuración de contacto: Véase Instrucciones de operación adjuntas. Descarga Electroestática (ESD) PRECAUCIÓN: El aparato incluye piezas electrónicas que son susceptibles a los daños provocados por la electricidad estática. Observar los adecuados procesos para remover, instalar o manipular las tareas y medios de circuitos eléctricos internos Proceso de operación: 1. Desconectar la fuente eléctrica de la unidad. 2. La persona debe ponerse a tierra mediante una palanca acodada o por otro medio seguro y apropiado para dicho fin antes de instalar, sacar o ajustar el circuito impreso eléctrico u otro medio interno. 3. El circuito impreso debe ser transportado en embalaje conductivo. Las tarjetas no pueden sacarse de la cubierta protectora exclusivamente directamente antes de la instalación. Las tarjetas desmontadas deben colocarse sin tardar en el embalaje protector utilizado para manipulación, almacenamiento o devolución a la fábrica. Notas: Esto equipo no es el único contenido de piezas susceptibles a la descarga electroestática (ESD). En la mayoría de los medios electrónicos modernos se encuentran piezas fabricadas por tecnología de óxido metálico. (NMOS, SMOS etc.). Las experiencias confirman que incluso una mínima electricidad estática puede dañar o destruir dichos medios. Las piezas averiadas, aunque funcionen aparentemente bien, indican una falla inicial. A-19 Section A - Essential Instructions Installation and Operation Manual Flow Controllers for Gas and Liquid Service X-VA-FC-eng Part Number: 541B045AAG December, 2015 Swedish Väsentliga anvisningar. Läs detta innan du fortsätter ! Brooks Instrument konstruerar, tillverkar och testar sina produkter med syfte att uppfylla alla nationella och internationella standarder. Dessa produkter måste installeras på rätt sätt, handhas och underhållas för att de skall fungera kontinuerligt enligt deras normala specifikation. De följande anvisningarna bör följas och integreras till Ert säkerhetsprogram varje gång när Brooks Instruments produkter installeras, handhas och underhålls. x För att garantera angiven funktion, använd kvalificerad personal till att installera, handha, uppgradera, programmera och serva produkten. x Läs alla instruktioner innan produkten installeras, startas upp och underhålls. Om du finner att denna instruktionshandbok inte är den rätta instruktionsboken, titta på i slutet av pärmen för information om hur man kan kontakta lokala representanter. Spara denna instruktions manual för senare behov. VARNING: Kör inte detta instrument utanför dess specifikationer som är angiven i Instruktionsboken. Undvikande att ta denna varning kan leda till allvarliga personliga skador och / eller skada utrustningen. x Om du inte förstår någon av dessa instruktioner, kontakta din representant för Brooks Instrument för klarläggande. x Följ alla varningar och instruktioner som följer med leveransen av denna produkt. x Installera din utrustning på sättet som anges i den gällande handbokens installationsanvisningar och enligt tillämpliga lokala och nationella föreskrifter. Koppla varje produkt till föreskriven ström- och tryckkällan. x Igångsättning: (1) Koppla långsamt på flöde i systemet. Öppna processventiler sakta för att undvika för höga flöden. (2) Kontrollera läckor vid mätarens anslutningar för in- och utlopp. Om inget läckage förekommer, kör systemet upp till drifttrycket. x Kontrollera att processledningens tryck är bortkopplat före service. I fall det behöves kompletteras med nya delar, se till att komponenter föreskrivna av Brooks Instrument används. Samt att kvalificerad personal utför arbetet. Ej rekommenderade komponenter och åtgärder kan påverka produktens prestanda och sätta din driftsäkerhet på spel. ”Felaktiga” ersättningar kan orsaka eld, elektriska skador samt felaktig funktion. x Se till att anordningens kåpor och skyddslock ligger på sin plats med syfte att förebygga elektriska kontakt och personliga skador; det enda undantag gäller när underhållsarbete utförs av kvalificerad personal. VARNING: I fall av - flödesmätare / regulatorer för vätskor: Ifall ventiler före och efter skall stängas av, måste alla ledningar tömmas på all vätska. Att ej tömma ledningar alt koppla bort trycket kan göra så att vätskans värmeutvidgning kan spräcka / skada utrustningen och orsaka personliga skador. European Pressure Equipment Directive (PED) - (Rådets Direktiv 99/36/EG av den 29 april 1999[1] om transportabla tryckbärande anordningar) Alla utrustning för tryck med ett tryck över 0.5 Bar(g) bar och större demensioner än 25 mm eller 1" (inch) faller under Tryck direktiv 99/36/EG av den 29 april 1999[1] om transportabla tryckbärande anordningar - PED. x Den här Instruktionsbokens Sektion ” Specifikation” innehåller anvisningar gällande PED Direktivet. x Mätare som beskrivs i denna Instruktionsbok är i överensstämmelse med EN Direktivet 97/23/EC. x Brooks Instruments alla flödesmätare faller under flödesgrupp nr. I. x Mätare som är större än 25 mm eller 1" (inch) överensstämmer med PED kategorier I, II eller III. x Mätare på 25mm eller 1" (inch) eller mindre faller under Sound Engineering Practice (SEP) (God Teknisk Praxis). European Electromagnetic Compatibility (EMC) - Elektromagnetisk kompatibilitet Brooks Instrument (elektriska/elektroniska) CE-märkta anordningar har redan genomgått ett framgångsrikt prov enligt regleringar under Electromagnetic Compatibility (EMC directive 2004/108/EC). Man måstre dock ägna särskild uppmärksamhet till valet av signalkabeln som skall används för CE-märkta anordningar. Signalkablars, packboxars och kontakdons kvalitet: Brooks Instrument levererar högkvalitativa kablar som överensstämmer med specifikation för CE-intygade produkter. Om man använder sin egen signalkabel, då bör man använda en kabel som är fullständigt skärmad med en 100% avskärmning. “D” eller “Cirkelformiga” kontakdon skall vara skärmade med metalliska avskärmningar. Om det är användbart, bör metallpackboxar som ger en bra fastspänning för kabelskärmar användas. Kabelavsärmningen måste kopplas till den metalliska skärmande anordningen eller packboxen och skärmas vid båda ändar runt omkring. Avskärmningens avspänning måste jordas. Card Edge Kontaktdon är icke metalliska. För att överensstämma med krav på CE-intyg, skall de kablarna som används vara skärmade med 100% skärmning. Skärmningen måste jordas. Vad gäller stiftkonfigurationen: Se den bifogade Instruktionshandboken. ESD (Elektrostatiska urladdningar) OBS: Denna utrustning innehåller elektroniska komponenter som är lättpåverkade av skada orsakad av statisk elektricitet. Lämplig hanteringsprocedur måste följas när man tar bort, installerar eller på något annat sätt hanterar inre kretskort eller andra anordningar. 1. Ström till enheten måste kopplas från. 2. Personalen måste jordas med hjälp av ett armband eller något annat säkert medel innan något kretskort eller andra inre anordningar installerras, tas bort eller justeras. 3. Kretskort måste transporteras i en speciell förpackning för elektronik. Kort skall ej tas bort från deras skydsskåpa innan man skall installera dem. De borttagna korten bör omedelbart läggas i speciell förpackning för transport, lagring eller återlämnande till fabriken. Anmärkningar: Dessa instrument är ej unika vad gäller dess ESD (Elektrostatiska urladdningar) - känsliga komponenter. De flesta samtida konstruktioner innehåller komponenter som utnyttjar metalloxid teknologi (NMOS, SMOS, o.s.v.). Erfarenhet har visat att även små mängder av statisk elektricitet kan skada eller förstöra dess komponenter. Skadade komponenter - även om de annars verkar fungera ordentligt – har ofta en kortare livslängd. . A-20 Installation and Operation Manual X-VA-FC-eng Part Number: 541B045AAG December, 2015 Flow Controllers for Gas and Liquid Service THIS PAGE WAS INTENTIONALLY LEFT BLANK Flow Controllers for Gas and Liquid Service Installation and Operation Manual X-VA-FC-eng Part Number: 541B045AAG December, 2015 LIMITED WARRANTY Seller warrants that the Goods manufactured by Seller will be free from defects in materials or workmanship under normal use and service and that the Software will execute the programming instructions provided by Seller until the expiration of the earlier of twelve (12) months from the date of initial installation or eighteen (18) months from the date of shipment by Seller. Products purchased by Seller from a third party for resale to Buyer (“Resale Products”) shall carry only the warranty extended by the original manufacturer. All replacements or repairs necessitated by inadequate preventive maintenance, or by normal wear and usage, or by fault of Buyer, or by unsuitable power sources or by attack or deterioration under unsuitable environmental conditions, or by abuse, accident, alteration, misuse, improper installation, modification, repair, storage or handling, or any other cause not the fault of Seller are not covered by this limited warranty, and shall be at Buyer’s expense. Goods repaired and parts replaced during the warranty period shall be in warranty for the remainder of the original warranty period or ninety (90) days, whichever is longer. This limited warranty is the only warranty made by Seller and can be amended only in a writing signed by an authorized representative of Seller. BROOKS SERVICE AND SUPPORT Brooks is committed to assuring all of our customers receive the ideal flow solution for their application, along with outstanding service and support to back it up. We operate first class repair facilities located around the world to provide rapid response and support. Each location utilizes primary standard calibration equipment to ensure accuracy and reliability for repairs and recalibration and is certified by our local Weights and Measures Authorities and traceable to the relevant International Standards. Visit www.BrooksInstrument.com to locate the service location nearest to you. START-UP SERVICE AND IN-SITU CALIBRATION Brooks Instrument can provide start-up service prior to operation when required. For some process applications, where ISO-9001 Quality Certification is important, it is mandatory to verify and/or (re)calibrate the products periodically. In many cases this service can be provided under in-situ conditions, and the results will be traceable to the relevant international quality standards. CUSTOMER SEMINARS AND TRAINING Brooks Instrument can provide customer seminars and dedicated training to engineers, end users and maintenance persons. Please contact your nearest sales representative for more details. HELP DESK In case you need technical assistance: 1 888 554 FLOW Americas Europe +31 (0) 318 549 290 Asia +81 (0) 3 5633 7100 Due to Brooks Instrument's commitment to continuous improvement of our products, all specifications are subject to change without notice. TRADEMARKS Brooks ....................................................................... Brooks Instrument, LLC Kalrez ....................................................................... DuPont Dow Elastomers NRS .......................................................................... Brooks Instrument, LLC Teflon ............................................................. E.I. DuPont de Nemours & Co. Viton ........................................................... DuPont Performance Elastomers
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48

Brooks FC8744 / FC8800 / FC8900 Handleiding

Type
Handleiding