INSTALLATION INSTRUCTIONS
KLIMA.CO.UK
2
Dear Customer,
Congratulations on the purchase of this
KLIMA product. The KLIMA foil mat has
been manufactured from high quality,
durable materials. To guarantee the
optimum function of your product, you
must read and follow these Installation
instructions and points of attention. We
can only offer you the full guarantee if
the Klima Foil Mat is correctly installed
in accordance with the installation
instructions. Carefully read these
instructions prior to installation and
make sure you use the correct tools and
materials. You must have the electrical
installation carried out by a qualified
electrician in accordance with the IEE
regulations who must also complete the
rear page of this booklet including noting
the unique serial number of the mat and
the readings taken during installation as
this will validate any warranty claim.
Technical data:
Cable type: Double-conductor heating cable
with earthing shield.
Construction: Multi-stranded heating cable
with double insulation, earthing shields
Nominal voltage : 230 Volts
Nominal capacity : 140W/
Connecting wire : 3 x 1.5 mm²
Connecting wire : 5 metres length
Cable diameter : 3 mm
Wattage per m1 : 10.5 Watt
Cable standard : IEC800 class II
Guarantee : 10 years
1. Check:
Before you start, check the contents of the
package.
Heating mat
Control card
Flexible sensor tube
Installation instructions
Thermostat including floor sensor must
be purchased separately. It must be set to
a maximum temperature of 28 degrees
Celsius.
2. Measurement data:
Type Watt Size Amp Ohm
1 m 140 W 0,5x2m 0,6 378
2 m2 280 W 0,5x4m 1,2 189
3 m2 420 W 0,5x6m 1,8 126
4 m2 560 W 0,5x8m 2,4 94
5 m2 700 W 0,5x10m 3,0 76
6 m2 840 W 0,5x12m 3,7 63
7 m2 980 W 0,5x14m 4,3 54
8 m2 1120 W 0,5x16m 4,9 47
9 m2 1260 W 0,5x18m 5,5 42
10 m2 1400 W 0,5x20m 6,1 38
Klima Underoor Heating
Karelia House, Keltneyburn, Comrie Bridge
By Aberfeldy, PH15 2LS
Helpdesk 01887 822020
Website www.klima.co.uk
3
3. Points of attention:
This product is ONLY suitable for installation
under so-called dry floor coverings - Click
together laminate or Engineered Wooden
flooring). The sub floor on which the PS
insulation is to be laid on must be must be
sufficiently solid and pressure-resistant and
the heating system must be laid on top of a
PS Insulation material min 5mm thickness.
Check beforehand whether the surface
of the heating mat corresponds to the
free floor area to be heated and whether
sufficient current capacity (Amps) is
available. WE WILL NOT ACCEPT RETURNS
IF THE OUTER SEALED PACKING OF THE
MAT HAS BEEN OPENED.
During Installation and other work, be
careful of sharp objects that may damage
the heating cable.
You should check the mat between and
after each work step (See point 7) and fill
in the measured values on the middle
page. Keep this completed page in your
meter cupboard, as this is required for any
warranty claim.
The Heating cables must never be laid on
top of each other and must not cross each
other. If multiple mats are in a space, they
must be wired in parallel and a suitably
rated junction box may be incorporated
so that only one power cable runs to the
thermostat. Maximum capacity of the
thermostat is 16 Amps, if the combine
Amperage of the mats exceed 16 Amps
then a suitably rated contactor must be
used. The thermostat may only be installed
by a qualified Electrician in accordance with
IEE regulations. We recommend if wiring 3
or more mats in parallel via a contactor that
at least 1 of the mats is wired directly into
the thermostat.
The connection cable may be extended or
shortened, always leaving a minimum of
0.5 metres of connection wire. The heating
cable must NOT BE CUT OR SHORTENED.
The mats must not be laid on top of each
other and the heating cables must never
cross each other! The warm/cold cable
junction lies just inside the heating mat.
The sensor cable may be extended or
shortened. The sensor must be installed in
the middle of a heating loop for optimal
temperature recording. The sensor (tube)
may also not cross heating cables. Make
sure that the sensor is mounted at distance
(min. 50 cm) from (hidden) radiator and
water pipes, drains and electricity cables.
The sensor should always remain in the
sensor tube. Cap the end of the tube to
prevent the sensor from getting stuck
during processing. If the sensor ever needs
to be replaced, it can be easily removed.
The Foil Mat should never be placed under
fixed objects such as wall units, kitchen
units and must be able to give off its heat
unhindered. In general, a wall clearance of
50 mm should be maintained.
IMPORTANT: Cover all exposed heating
cables (which are visible when the
Foil Mat is turned over) at the top
and bottom with Aluminum tape. This
will ensure that the mat’s earth jacket
remains intact.
The power supply must remain
disconnected during installation.
Connection must be made via an RCD
switch in accordance with the NEN 1010
installation standards. If several mats are
installed in a room, a suitable rated junction
box can be placed in front of the power
point so that only one power cable runs to
the thermostat. The maximum connection
capacity of the thermostat is 16 Amps. It is
recommended that the thermostat does
not exceed a temperature of 28 degrees
Celsius.
4. Required materials:
An underfloor heating system
Approx. 2m (flexible) electrical conduit
(16 mm)
Electricity box (min 50 mm deep)
Power point with earthing
A multimeter to test the mat between all
work steps
Scissors
Aluminium tape
4
5. Preparations:
Determine the place where the thermostat
is to be installed, using a standard flush-
mounting box with a minimum depth of
50 mm. Preferably at a height of 1.40 m for
ease of use. Cut the necessary slots and
install the flush-mounting box, electrical
conduit and floor sensor conduit. Then the
floor sensor must be located within its own
conduit pipe. We always recommend the
mat is installed upon a PS type of insulation
designed for under wood flooring with a
minimum thickness of 5mm.
6. Substrate:
Make sure the surface on which the mat is
to be installed is flat, clean, and free of dust
and grease. Always pay attention to the
points of attention mentioned in chapter 3
and a minimum of 5mm PS insulation type
underlay is laid.
7. Check resistance values:
You must check the mat between and after
each step using a multimeter and fill in the
measured values on the back page. Measure
between the resistance wires and use the
table shown in point 2. The Ohms value may
deviate max. 10%. Also measure between
the resistance wire and the ground sleeve.
The meter must not turn off during this
measurement.
Keep the completed card and completed
Instruction Manual in your meter
cupboard. It is part of your guarantee.
8. Apply PS insulation:
First place PS floor insulation of minimum
thickness of 5mm. This must cover the entire
floor area! Tape the sheets down to prevent
the insulation from moving. Make sure the
floor is clean and that no sharp objects
can come into contact with or fall onto the
heating mat during installation.
v0120
WAARSCHUWING!
ONDER DE VLOER IS EEN 230V VLOERVERWARMINGSSYSTEEM
GEINSTALLEERD! NOOIT BOREN OF SCHROEVEN IN DE VLOER!
ZIE TEKENING/FOTO VOOR DE POSITIE VAN HET SYSTEEM.
Vloerverwarming geïnstalleerd in:
......................................................................
Controlemetingen:
A: Tussen beide weerstandsdraden (10% marge)
B: Tussen weerstandsdraad #1 en aarde (Dit moet "0" zijn)
C: Tussen weerstandsdraad #2 en aarde (Dit moet "0" zijn
)
Uit verpakking:
A:......................Ohm
B:......................Ohm
C:......................Ohm
Installateur:
............................................................
Na inpassen op vloer:
A:......................Ohm
B:......................Ohm
C:......................Ohm
Datum:
........../........../20.........
Na aanbrengen
laminaat:
A:......................Ohm
B:......................Ohm
C:......................Ohm
Handtekening:
............................................................
Bewaar deze controlekaart op een zichtbare
plaats in de meterkast!
Controlemetingen:
A: Tussen beide weerstandsdraden (10% marge)
B: Tussen weerstandsdraad #1 en aarde (Dit moet "0" zijn)
C: Tussen weerstandsdraad #2 en aarde (Dit moet "0" zijn
Uit verpakking:
A:......................Ohm
B:......................Ohm
Installateur:
............................................................
Bewaar deze controlekaart op een zichtbare
plaats in de meterkast!
5
9. Sensor placement:
Cut a trench out of the PS insulation and
subfloor for the floor sensor tube, place the
sensor tube incl. floor sensor and tape it
down. When placing the Foil Mat, make sure
that the sensor is exactly between 2 cable
loops. CAUTION: Never place the sensor
near a (concealed) radiator pipe - min
distance away 50cm, and never mount it
crosswise under a heating cable!
10. Fitting the mat:
(Important details on page 6) when rolling
out the mat, maintain a minimum gap of
50mm from wall’s & fixed furniture. If the
mat is not at the required length, it can
be cut and rotated to run back along itself
in parallel e.g. by cutting the mat without
damaging the heating cable. This can be
repeated several times. Once the mat has
been laid, test it again using the multimeter.
Please ensure that Aluminum tape is
applied to the width of the mat where it has
been cut and rotated.
v0120
WAARSCHUWING!
ONDER DE VLOER IS EEN 230V VLOERVERWARMINGSSYSTEEM
GEINSTALLEERD! NOOIT BOREN OF SCHROEVEN IN DE VLOER!
ZIE TEKENING/FOTO VOOR DE POSITIE VAN HET SYSTEEM.
Vloerverwarming geïnstalleerd in:
......................................................................
Controlemetingen:
A: Tussen beide weerstandsdraden (10% marge)
B: Tussen weerstandsdraad #1 en aarde (Dit moet "0" zijn)
C: Tussen weerstandsdraad #2 en aarde (Dit moet "0" zijn
)
Uit verpakking:
A:......................Ohm
B:......................Ohm
C:......................Ohm
Installateur:
............................................................
Na inpassen op vloer:
A:......................Ohm
B:......................Ohm
C:......................Ohm
Datum:
........../........../20.........
Na aanbrengen
laminaat:
A:......................Ohm
B:......................Ohm
C:......................Ohm
Handtekening:
............................................................
Bewaar deze controlekaart op een zichtbare
plaats in de meterkast!
Controlemetingen:
A: Tussen beide weerstandsdraden (10% marge)
B: Tussen weerstandsdraad #1 en aarde (Dit moet "0" zijn)
C: Tussen weerstandsdraad #2 en aarde (Dit moet "0" zijn
Uit verpakking:
A:......................Ohm
B:......................Ohm
C:......................Ohm
Installateur:
............................................................
Bewaar deze controlekaart op een zichtbare
plaats in de meterkast!
6
Thermostat
Sensor
Thermostat
Sensor
Thermostat
Sensor
Thermostat
Sensor
11. Finishing:
IMPORTANT: Cover all exposed heating
cables (which are visible when the FoilMat
is turned over) at the top and bottom with
Aluminium tape. This leaves the mats
protective earth intact.
You can then use the same tape to fix
the FoilMat to the subfloor. Then lay the
laminate or wooden floorboards according
to the manufacturer’s instructions and
finish.
12. Connecting thermostat:
Any Connection must be carried out by
a suitably qualified heating engineer in
accordance with local regulations. Before
installing the controller, always switch off
the electricity in the meter cupboard. For
installation, operation and programming
of the thermostat, please refer to the
instructions enclosed with the thermostat.
We always recommend installing via a
suitable rated dedicated RCD.
7
Under Wood Heating mat installed in: ............................................................................
Resistance readings:
A: Between centre core wires (within 10% margin!)
B: Between centre core wire #1 and the earth (This should read "indefinite/overload")
C: Between centre core wire #2 and the earth (This should read "indefinite/overload")
KEEP THIS COMPLETED MANUAL AND YOUR COMPLETED
CONTROL CHECK IN THE METER CUPBOARD AS WE WILL
NEED THESE FOR ANY WARRANTY CLAIMS
Installer
............................................
Date
........../........../20.........
Signature
.............................................
ATTENTION!
A 230 VOLT HEATING IS SYSTEM INSTALLED
UNDERNEATH THE FLOORING! NEVER DRILL OR
SCREW INTO THE FLOOR! SEE LAYOUT DIAGRAM
ON NEXT PAGE FOR THE POSITION OF THE
UNDERFLOOR HEATING SYSTEM
Initial Reading:
A:......................Ohm
B:......................Ohm
C:......................Ohm
Mat/Cable Laid:
A:......................Ohm
B:......................Ohm
C:......................Ohm
After completion:
A:......................Ohm
B:......................Ohm
C:......................Ohm
Serial Number of the mat: ............................................
Layout diagram of the underfloor heating Installation:
Klima Underfloor Heating
Karelia House, Keltneyburn
By Aberfeldy, PH15 2LS
T 01887 822020
W www.klima.co.uk
EU Manufacturer
MAGNUM Heating Group
Stevinweg 8
4691 SM Tholen
THE NETHERLANDS
UK Importer
MAGNUM Heating Ltd.
Karelia House - Comrie Bridge
Keltneyburn - By Aberfeldy
PH15 2LS
UNITED KINGDOM
VAT / EORI Number:
GB693986263
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

klima Electric Under Wood Handleiding

Type
Handleiding

in andere talen