Productbeschrijving en toepassing
De Mastervolt Battery Watch schakelt de aangesloten belasting af bij:
• Onderspanning: de accuspanning is lager dan het ingestelde onderspanningniveau (U-low.off). De
belasting wordt pas weer ingeschakeld zodra de accuspanning hoger is dan het inschakelniveau (U-
low.on). Door een schakelvertraging (30 sec.) is de Battery Watch is ongevoelig voor kortstondige
spanningsvallen.
• Overspanning: de accuspanning is hoger is dan 15,5V / 31,0V (U-high.off). De belasting wordt weer
ingeschakeld zodra de accuspanning lager is 15,0V / 30,0V (U-high.on).
De Battery Watch is uitsluitend geschikt voor 12VDC en 24VDC installaties met een negatieve massa.
Installatie
Overtuig uzelf ervan dat de uitgang van de voedingsbron spanningsloos is gedurende de
installatiewerkzaamheden. Zorg er tevens voor dat er geen gebruikers zijn aangesloten op de
accugroepen ter voorkoming van onveilige situaties.
De Battery Watch kan warm worden als gevolg van grote stromen. Installeer de Battery Watch daarom
op een goed geventileerde plaats, bij voorkeur op een vlakke metalen ondergrond, met de koelribben
verticaal geplaatst. Monteer de Battery Watch zo dicht mogelijk bij de accu, maar nooit direct boven
een accu i.v.m. mogelijke corrosieve accudampen.
Aansluiten
Zie tekening (“installation”) voor de juiste wijze van aansluiten. Monteer de negatieve aansluitingen van
de accugroepen en de voedingsbron op een gemeenschappelijk massapunt.
Monteer een schakelaar tussen de “switch”-aansluiting en de massa wanneer u de Battery Watch als
hoofdschakelaar voor de aangesloten belasting wilt gebruiken.
Instellingen
De Battery Watch detecteert automatisch de nominale accuspanning (12V of 24V).
Aan de bovenzijde van de Battery Watch bevindt zich een DIP-switch voor het instellen van het
onderspanningniveau. Gebruik een kleine schroevendraaier om de instellingen te wijzigen. Zie tabel
“DIP-settings” voor instellingen.
Indien DIP-switches 1,2 en 3 tegelijkertijd op ‘ON’ staan ingesteld, reageert de Battery Watch niet op
onderspanningen. U kunt het geluidssignaal uitschakelen wanneer u DIP-switch 4 op ‘ON’ instelt.
Veiligheidsvoorschriften en –maatregelen
1. Installeer de Battery Watch volgens bovengenoemde instructies
2. Gebruik de Battery Watch nooit op een locatie met gas- of stofontploffingsgevaar.
3. Aansluitingen en beveiligingen moeten in overeenstemming met de plaatselijk geldende
voorschriften worden uitgevoerd.
4. Gebruik kabels met voldoende draaddoorsnee en houd alle afstanden zo kort mogelijk. Gebruik
deugdelijke kabelschoenen en draai alle aansluitmoeren goed aan. (zie ‘nut instruction’)
Garantiebepalingen
Mastervolt garandeert dat de Battery Watch is geproduceerd volgens de wettelijk van toepassing
zijnde normen en bepalingen. Gedurende de productie en voor aflevering zijn alle apparaten uitvoerig
getest en gecontroleerd. Wanneer niet volgens de in deze handleiding gegeven voorschriften,
aanwijzingen en bepalingen wordt gehandeld, kunnen beschadigingen ontstaan en/of het apparaat zal
niet aan de specificaties voldoen. Een en ander kan inhouden dat de garantie komt te vervallen.
De garantietermijn is twee jaar.
Aansprakelijkheid
Mastervolt kan niet aansprakelijk worden gesteld voor:
• Schade ontstaan door het gebruik van de Battery Watch
• Eventuele fouten in bijbehorende handleiding en de gevolgen daarvan
• Ander gebruik geldend als niet conform de bestemming van het product
INSTALLATION
ENGLISH
Product description and application
The Mastervolt Battery Watch disconnects its load in case of:
• Under voltage: the battery voltage is below the adjusted under voltage level (U-low.off). The load is
reconnected again when the battery voltage is higher than the switching level (U-low.on). Because of
a 30 seconds switching delay, the Battery Watch will not respond to short voltage dips.
• Over voltage: the battery voltage is above 15.5V / 31.0V (U-high.off). The load is reconnected again
when the battery voltage is below 15.0V / 30.0V (U-high.on).
The Battery Watch can only be applied in 12VDC and 24VDC installations with a negative common
ground
Installation
Be sure that the output of the supplying source is switched off during installation. Also be sure that no
consumers are connected to the batteries during installation, to prevent hazardous situations.
Install the Battery Watch not only as close as possible to the supplying source, but to the batteries as
well, but do not install The Battery Watch straight above the batteries because of possible corrosive
sulphur fumes. The battery isolator must be installed in a well-ventilated environment, as high currents
will heat up the battery isolator. Preferably, the Battery Watch should be mounted on a flat metal
surface with the fins vertical
Connections
For correct connection - see drawing “installation”. Connect the negative poles of the battery sets and
the supplying source to a common ground.
Connect a switch between the “switch”-connection and the common ground if you want to use the
Battery Watch as a main switch for the connected load.
Adjustments
The Battery Watch automatically detects the nominal battery voltage (12V or 24V).
On top of the Battery Watch a DIP-switch is situated to adjust the under voltage level. Refer to the
“DIP-settings” table for adjustments.
If DIP-switches 1, 2 and 3 are switched ‘ON’ together, the Battery Watch does not respond to under
voltages. If DIP-switch 4 is switched ‘ON’, the audible alarm is switched off.
Safety regulations and measures
1. Install the Battery Watch according to the stated instructions.
2. Never use the Battery Watch at a location where there is danger of gas or dust explosions.
3. Connections and safety features must be executed according to the locally applicable regulations.
4. Use cables with appropriate size wire and keep the cable connections as short as possible. Use
reliable terminals and fasten the bolts tightly, but do not over torque (also see ‘nut instruction’).
Guarantee terms
Mastervolt guarantees that the Battery Watch has been built according to the legally applicable
standards and stipulations. During production and before delivery all units were exhaustively tested
and controlled. If you fail to act in accordance with the regulations, instructions and stipulations of this
user’s manual, damage can occur and/or the unit will not fulfil the specifications. This may mean that
the guarantee will become null and void.
The guarantee period is 2 years.
Liability
Mastervolt cannot be held liable for:
• Damage resulting from the use of the Battery Watch.
• Possible errors in the included manual and the consequences of these.
• Use that is inconsistent with the purpose of the product.
BATTERY WATCH
SPECIFICATIONS
Article number 83 20 0150
Input Voltage 8 – 32V
Switch OFF under voltage (U-low.off) 9.0V…12.0V or 18.0V…24.0V (adjustable by DIP-settings)
Switch ON under voltage (U-low.on) 10.5V…13.0V or 21.0V…26.0V (adjustable by DIP-settings)
Switch OFF over voltage (U-high.off) 15.5V or 31.0V (fixed)
Switch ON over voltage (U-high.on) 15.0V or 30.0V (fixed)
Delay high voltage OFF 1 sec.
Delay high voltage ON 10 sec.
Delay low voltage OFF 30 sec.
Delay low voltage ON 10 sec.
Nominal Current 100A
Maximum Current (P30) 150A
Voltage drop <0.2V
Remote main switch (optional) Single pole, on-off contact (switching current: 1mA)
DIP SETTINGS
0 Audible alarm (buzzer) = ON
1 Audible alarm (buzzer) = OFF
Ç
1 ON
0 OFF
1 2 3 4 U-bat = 12V U-bat = 24V
È È È
U-low.off U-low.on U-low.off U-low.on
0 0 0 9.0V 10.5V 18.0V 21.0V
1 0 0 9.5V 11.0V 19.0V 22.0V
0 1 0 10.0V 11.5V 20.0V 23.0V
1 1 0 10.5V 12.0V 21.0V 24.0V
0 0 1 11.0V 12.5V 22.0V 25.0V
1 0 1 11.5V 13.0V 23.0V 26.0V
0 1 1 12.0V 13.0V 24.0V 26.0V
1 1 1 OFF OFF OFF OFF
LED INDICATIONS RECOMMENDED WIRE SIZES
LED #
DC-Current Wire size (up to 3 meters)
50-75 Amp 25 mm² (AWG 3)
75-100 Amp 35 mm² (AWG 1-2)
100-150 Amp 50 mm² (AWG 0)
1
2
3
4
Power
High battery
Low battery
Overload
LED: 1 2 3 4
On Over voltage Under voltage Overload
Aan Overspanning Onderspanning Overbelasting
Ein Überspannung Unterspannung Überladung
Marche Sur-tension Sous-tension Surcharge
On Sovratensione Bassa tensione Sovraccarico
On Sobretensión Subtensión Sobrecarga
+ –
Battery Accu
Akku Batterie
Batteria Battería
Battery charger
Acculader
Akkulader
Chargeur
Caricabatterie
Cargador
+
Load
Belasting
Last
Charge
Carico
Carga
Off
Uit
Aus
Arrêt
On
Aan
Ein
Marche
Ø 0,5 mm²
157 mm
140 mm
140 mm
70 mm
+
–
1 2 3 4
Remote main switch
Bediening als hoofdschakelaar
Fernbedienung Hauptschalter
Télécommande d’interrupteur principal
Commando interruttore per carico remoto
Remoto desconactador de battería