Documenttranscriptie
DIGITAL MIXING ENGINE
Owner’s Manual
EN
Explanation of Graphical Symbols
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION: TO REDUCE THE RISK OF
ELECTRIC SHOCK, DO NOT REMOVE
COVER (OR BACK). NO USER-SERVICEABLE
PARTS INSIDE. REFER SERVICING TO
QUALIFIED SERVICE PERSONNEL.
The lightning flash with arrowhead symbol
within an equilateral triangle is intended to alert
the user to the presence of uninsulated
“dangerous voltage” within the product’s
enclosure that may be of sufficient magnitude to
constitute a risk of electric shock to persons.
The exclamation point within an equilateral
triangle is intended to alert the user to the
presence of important operating and maintenance
(servicing) instructions in the literature
accompanying the product.
The above warning is located on the top of the unit.
IMPORTANT SAFETY INSTRUCTIONS
1
Read these instructions.
2
Keep these instructions.
3
Heed all warnings.
4
Follow all instructions.
5
Do not use this apparatus near water.
6
Clean only with dry cloth.
7
Do not block any ventilation openings. Install in
accordance with the manufacturer’s instructions.
8
Do not install near any heat sources such as
radiators, heat registers, stoves, or other
apparatus (including amplifiers) that produce heat.
9
Do not defeat the safety purpose of the polarized
or grounding-type plug. A polarized plug has two
blades with one wider than the other. A grounding
type plug has two blades and a third grounding
prong. The wide blade or the third prong are
provided for your safety. If the provided plug does
not fit into your outlet, consult an electrician for
replacement of the obsolete outlet.
10 Protect the power cord from being walked on or
pinched particularly at plugs, convenience
receptacles, and the point where they exit from the
apparatus.
WARNING
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,
DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE.
11 Only use attachments/accessories specified by
the manufacturer.
12 Use only with the cart, stand,
tripod, bracket, or table
specified by the manufacturer,
or sold with the apparatus.
When a cart is used, use
caution when moving the cart/
apparatus combination to avoid
injury from tip-over.
13 Unplug this apparatus during lightning storms or
when unused for long periods of time.
14 Refer all servicing to qualified service personnel.
Servicing is required when the apparatus has
been damaged in any way, such as power-supply
cord or plug is damaged, liquid has been spilled or
objects have fallen into the apparatus, the
apparatus has been exposed to rain or moisture,
does not operate normally, or has been dropped.
FCC INFORMATION (U.S.A.)
1. IMPORTANT NOTICE: DO NOT MODIFY THIS UNIT!
This product, when installed as indicated in the instructions contained in this manual, meets FCC requirements. Modifications not
expressly approved by Yamaha may void your authority, granted by
the FCC, to use the product.
2. IMPORTANT: When connecting this product to accessories and/
or another product use only high quality shielded cables. Cable/s
supplied with this product MUST be used. Follow all installation
instructions. Failure to follow instructions could void your FCC
authorization to use this product in the USA.
3. NOTE: This product has been tested and found to comply with the
requirements listed in FCC Regulations, Part 15 for Class “B” digital
devices. Compliance with these requirements provides a reasonable level of assurance that your use of this product in a residential
environment will not result in harmful interference with other electronic devices. This equipment generates/uses radio frequencies
and, if not installed and used according to the instructions found in
the users manual, may cause interference harmful to the operation
of other electronic devices. Compliance with FCC regulations does
not guarantee that interference will not occur in all installations. If
this product is found to be the source of interference, which can be
determined by turning the unit “OFF” and “ON”, please try to eliminate the problem by using one of the following measures:
Relocate either this product or the device that is being affected by
the interference.
Utilize power outlets that are on different branch (circuit breaker or
fuse) circuits or install AC line filter/s.
In the case of radio or TV interference, relocate/reorient the
antenna. If the antenna lead-in is 300 ohm ribbon lead, change the
lead-in to co-axial type cable.
If these corrective measures do not produce satisfactory results,
please contact the local retailer authorized to distribute this type of
product. If you can not locate the appropriate retailer, please contact Yamaha Corporation of America, Electronic Service Division,
6600 Orangethorpe Ave, Buena Park, CA90620
The above statements apply ONLY to those products distributed by
Yamaha Corporation of America or its subsidiaries.
* This applies only to products distributed by YAMAHA CORPORATION OF AMERICA.
ADVARSEL!
IMPORTANT NOTICE FOR THE UNITED KINGDOM
Connecting the Plug and Cord
WARNING: THIS APPARATUS MUST BE EARTHED
IMPORTANT. The wires in this mains lead are coloured in accordance
with the following code:
GREEN-AND-YELLOW : EARTH
BLUE
: NEUTRAL
BROWN
: LIVE
As the colours of the wires in the mains lead of this apparatus may not
correspond with the coloured markings identifying the terminals in
your plug proceed as follows:
The wire which is coloured GREEN-and-YELLOW must be connected
to the terminal in the plug which is marked by the letter E or by the
safety earth symbol
or colored GREEN or GREEN-and-YELLOW.
The wire which is coloured BLUE must be connected to the terminal
which is marked with the letter N or coloured BLACK.
The wire which is coloured BROWN must be connected to the terminal which is marked with the letter L or coloured RED.
• This applies only to products distributed by Yamaha-Kemble Music (U.K.) Ltd.
(class B)
(3 wires)
NEDERLAND / THE NETHERLANDS
• Dit apparaat bevat een lithium batterij voor geheugen back-up.
• This apparatus contains a lithium battery for memory back-up.
• Raadpleeg uw leverancier over de verwijdering van de batterij op het
moment dat u het apparaat ann het einde van de levensduur afdankt
of de volgende Yamaha Service Afdeiing:
Yamaha Music Nederland Service Afdeiing
Kanaalweg 18-G, 3526 KL UTRECHT
Tel. 030-2828425
• For the removal of the battery at the moment of the disposal at the
end of the service life please consult your retailer or Yamaha Service
Center as follows:
Yamaha Music Nederland Service Center
Address : Kanaalweg 18-G, 3526 KL UTRECHT
Tel
: 030-2828425
• Gooi de batterij niet weg, maar lever hem in als KCA.
• Do not throw away the battery. Instead, hand it in as small chemical
waste.
(lithium disposal)
Lithiumbatteri—Eksplosionsfare ved fejlagtig håndtering. Udskiftning
må kun ske med batteri af samme fabrikat og type. Levér det brugte
batteri tilbage til leverandoren.
VARNING
Explosionsfara vid felaktigt batteribyte. Använd samma batterityp eller
en ekvivalent typ som rekommenderas av apparattillverkaren.
Kassera använt batteri enligt fabrikantens instruktion.
VAROITUS
Paristo voi räjähtää, jos se on virheellisesti asennettu. Vaihda paristo
ainoastaan laitevalmistajan suosittelemaan tyyppiin. Hävitä käytetty
paristo valmistajan ohjeiden mukaisesti.
(lithium caution)
PRECAUTIONS
PLEASE READ CAREFULLY BEFORE PROCEEDING
* Please keep this manual in a safe place for future reference.
WARNING
Always follow the basic precautions listed below to avoid the possibility of serious injury or even death from
electrical shock, short-circuiting, damages, fire or other hazards. These precautions include, but are not limited
to, the following:
Power supply/Power cord
Water warning
• Only use the voltage specified as correct for the device. The required
voltage is printed on the name plate of the device.
• Do not expose the device to rain, use it near water or in damp or wet
conditions, or place containers on it containing liquids which might spill
into any openings.
• Use only the specified power cord .
• Do not place the power cord near heat sources such as heaters or
radiators, and do not excessively bend or otherwise damage the cord,
place heavy objects on it, or place it in a position where anyone could walk
on, trip over, or roll anything over it.
Do not open
• Do not open the device or attempt to disassemble the internal parts or
modify them in any way. The device contains no user-serviceable parts. If
it should appear to be malfunctioning, discontinue use immediately and
have it inspected by qualified Yamaha service personnel.
• Never insert or remove an electric plug with wet hands.
If you notice any abnormality
• If the power cord or plug becomes frayed or damaged, or if there is a
sudden loss of sound during use of the device, or if any unusual smells or
smoke should appear to be caused by it, immediately turn off the power
switch, disconnect the electric plug from the outlet, and have the device
inspected by qualified Yamaha service personnel.
• If this device should be dropped or damaged, immediately turn off the
power switch, disconnect the electric plug from the outlet, and have the
device inspected by qualified Yamaha service personnel.
CAUTION
Always follow the basic precautions listed below to avoid the possibility of physical injury to you or others, or
damage to the device or other property. These precautions include, but are not limited to, the following:
Power supply/Power cord
Location
• Remove the electric plug from the outlet when the device is not to be used
for extended periods of time, or during electrical storms.
• When removing the electric plug from the device or an outlet, always hold
the plug itself and not the cord. Pulling by the cord can damage it.
• Before moving the device, remove all connected cables.
• Avoid setting all equalizer controls and faders to their maximum.
Depending on the condition of the connected devices, doing so may cause
feedback and may damage the speakers.
• Do not expose the device to excessive dust or vibrations, or extreme cold
or heat (such as in direct sunlight, near a heater, or in a car during the day)
to prevent the possibility of panel disfiguration or damage to the internal
components.
• Do not place the device in an unstable position where it might accidentally
fall over.
• Do not block the vents. This device has ventilation holes at the front and
rear to prevent the internal temperature from rising too high. In particular,
do not place the device on its side or upside down, or place it in any
poorly-ventilated location, such as a bookcase or closet.
• Do not use the device in the vicinity of a TV, radio, stereo equipment,
mobile phone, or other electric devices. Otherwise, the device, TV, or radio
may generate noise.
4
DME64N/24N Owner’s Manual
(5)-1
1/2
Connections
Handling caution
• Before connecting the device to other devices, turn off the power for all
devices. Before turning the power on or off for all devices, set all volume
levels to minimum.
• Do not insert your fingers or hand in any gaps or openings on the device
(vents, ports, etc.).
• Be sure to connect to a properly grounded power source. A ground screw
terminal is provided on the rear panel for safely grounding the device and
preventing electrical shock.
• Avoid inserting or dropping foreign objects (paper, plastic, metal, etc.)
into any gaps or openings on the device (vents, ports, etc.) If this
happens, turn off the power immediately and unplug the power cord from
the AC outlet. Then have the device inspected by qualified Yamaha service
personnel.
• Do not use the device or headphones for a long period of time at a high or
uncomfortable volume level, since this can cause permanent hearing loss.
If you experience any hearing loss or ringing in the ears, consult a
physician.
Maintenance
• Remove the power plug from the AC outlet when cleaning the device.
• Do not rest your weight on the device or place heavy objects on it, and
avoid use excessive force on the buttons, switches or connectors.
Backup battery
• This device has a built-in backup battery. When you unplug the power
cord from the AC outlet, the internal SRAM data is retained. However, if the
backup battery fully discharges, this data will be lost. When the backup
battery is running low, the Display indicates “Low Battery” or “No Battery.”
In this case, immediately save the data to an external devices such as a
computer, then have qualified Yamaha service personnel replace the
backup battery.
Yamaha cannot be held responsible for damage caused by improper use or modifications to the device, or data that is lost or destroyed.
Always turn the power off when the device is not in use.
The performance of components with moving contacts, such as switches, volume controls, and connectors, deteriorates over time. Consult qualifi ed Yamaha service
personnel about replacing defective components.
• The illustrations in this document are for instructional purposes, and may appear somewhat different from the actual equipment.
• The bitmap fonts used in this device have been provided by and are the property of Ricoh Co., Ltd.
• CobraNet and Peak Audio are trademarks of Cirrus Logic, Inc.
• Ethernet is a trademark of Xerox Corporation.
• All other trademarks are the property of their respective holders and are hereby acknowledged.
(5)-1
2/2
DME64N/24N Owner’s Manual
5
Foreword
Foreword
Thank you for choosing a Yamaha DME64N/24N Digital Mixing Engine.
Using the supplied DME Designer software, the DME64N and DME24N can be easily configured to handle
a wide range of audio processing applications – institutional audio installations, sub-mixing, speaker system
control, matrix and routing, multi-effect processing, and much more.
In order to take full advantage of the features and performance provided by the DME64N/24N, we urge you
to read this owner’s manual thoroughly before use, and keep it in a safe place for future reference.
The Yamaha Pro Audio web site is at: http://www.yamahaproaudio.com/
6
DME64N/24N Owner’s Manual
Contents
Contents
About the Documentation . . . . . . . . . . . . . . . . . 8
Supplied Accessories . . . . . . . . . . . . . . . . . . . . . 8
DME64N and DME24N I/O Configuration . . 8
Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
DME64N/24N Audio System Overview 9
The DME64N/24N Configurable Digital Mixing
Engine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
System Examples . . . . . . . . . . . . . . . . . . . . . . . 10
DME64N/24N Audio System Network . . . . . 13
DME64N/24N Audio System Control . . . . . . 14
DME Designer . . . . . . . . . . . . . . . . . . . . . . . . 15
The Controls and Connectors
16
Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Preparation
20
Setup Procedure. . . . . . . . . . . . . . . . . . . . . . . . 20
I/O Card Installation . . . . . . . . . . . . . . . . . . . . 22
Compatible I/O Cards . . . . . . . . . . . . . . . . . . . . . . . . . . 22
I/O Card Installation Procedure . . . . . . . . . . . . . . . . . . . 23
Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Signal Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
USB Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Ethernet Connection ([NETWORK] Connector) . . . . . 27
MIDI Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
GPI Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
CASCADE Connection (DME64N only) . . . . . . . . . . . 32
WORD CLOCK Connection . . . . . . . . . . . . . . . . . . . . 33
REMOTE Connection . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Analog Audio Connection ([IN] and [OUT] Connectors)
(DME24N only). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
I/O Slots. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Panel Operation and Displays
38
The Panel Buttons and Displays . . . . . . . . . . . 38
Main Display . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Parameter Edit Displays. . . . . . . . . . . . . . . . . . 40
Editing User Defined Parameters . . . . . . . . . . . . . . . . . .42
Mute Switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42
Output Level Control . . . . . . . . . . . . . . . . . . . . . . . . . . .42
Scene Recall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
Scene Store . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44
Spectrum Display. . . . . . . . . . . . . . . . . . . . . . . 45
Level Meter Display . . . . . . . . . . . . . . . . . . . . . 46
Utility Displays . . . . . . . . . . . . . . . . . . . . . . . . 47
Items accessible via the Utility display. . . . . . . . . . . . . . .47
Utility Display Operation . . . . . . . . . . . . . . . . . . . . . . . .48
Info Page. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48
Network Settings (Net) Page. . . . . . . . . . . . . . . . . . . . . .48
Display Setup (Disp) Page . . . . . . . . . . . . . . . . . . . . . . .49
Security Setup (Lock) Page . . . . . . . . . . . . . . . . . . . . . . .50
Miscellaneous Setup (Misc) Page . . . . . . . . . . . . . . . . . .51
Word Clock Setup (WCLK) Page. . . . . . . . . . . . . . . . . .51
Slot Information (Slot) Page . . . . . . . . . . . . . . . . . . . . . .52
MIDI Setup (MIDI) Page. . . . . . . . . . . . . . . . . . . . . . . .52
GPI Setup (GPI) Page. . . . . . . . . . . . . . . . . . . . . . . . . . .53
Head Amplifier Setup (HA) Page . . . . . . . . . . . . . . . . . .54
Cascade Setup (CASCAD) Page . . . . . . . . . . . . . . . . . . .55
Introduction
DME64N/24N
Audio System
Overview
The Controls
and Connectors
Preparation
Panel Operation
and Displays
Appendix
Appendix
56
Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
ICP1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56
CP4SW, CP4SF, and CP1SF . . . . . . . . . . . . . . . . . . . . .59
Error Messages. . . . . . . . . . . . . . . . . . . . . . . . . 61
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . 63
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Control I/O . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Connector Pin Assign . . . . . . . . . . . . . . . . . . . 66
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
MIDI Data Format . . . . . . . . . . . . . . . . . . . . . 69
Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
DME64N/24N Owner’s Manual
7
Introduction
About the Documentation
The following manuals are provided with the DME64N/24N.
DME64N/24N Owner’s Manual (This document)
This document covers the specifications, installation, and operation of the DME64N/24N.
DME Designer Installation Guide
This document covers the installation of the DME Designer software application and related drivers (USBMIDI driver, DME-N Network driver) on a computer, computer setup, and connection of the computer to
the DME64N/24N.
Introduction
DME Designer Owner’s Manual (PDF file)
The DME Designer Manual describes operation of the DME Designer software as well as the functions of the
individual modules that can be used.
Supplied Accessories
•
•
•
•
DME64N/24N Owner’s Manual (This document)
DME Designer Installation Guide
CD-ROM
AC power cord
•
•
•
•
AC plug clamp
Euroblock plug (16P) x 2
Euroblock plug (8P) x 4 (DME64N only)
Euroblock plug (3P) x 16 (DME24N only)
DME64N and DME24N I/O Configuration
The DME64N has four I/O card slots, while the DME24N has one I/O card slot and eight channels of builtin analog audio I/O.
A single I/O card can handle up to 16 channels of audio I/O, so the DME64N can handle a maximum of 64
audio I/O channels. The DME24N can handle up to 24 audio I/O channels.
The DME64N has approximately double the DSP processing power of the DME24N.
Options
Control Panels
•
•
•
•
ICP1 Intelligent Control Panel
CP4SW Control Panel
CP4SF Control Panel
CP1SF Control Panel
N OT E
Refer to the appendix on page 56 for information about the control panels.
mini-YGDAI (Yamaha General Digital Audio Interface) I/O Cards
• MY16-C, MY16-AT, MY16-AE, MY16-TD, and others.
N OT E
Refer to I/O Card Installation on page 22 for information on I/O card installation and the types of I/O cards that can be used.
8
DME64N/24N Owner’s Manual
The DME64N/24N Configurable Digital Mixing Engine
DME64N/24N Audio System Overview
The DME64N/24N Configurable Digital Mixing Engine
In addition to basic mixing and matrix output functions, the DME64N/24N includes a full range of processing modules –
equalizers, compressors, reverb and delay, effects, etc. – that can be patched together using the DME Designer software to
support just about any audio system you need. It can serve as the central audio processing and routing unit in an installed
system, or it can serve to augment the functionality of an existing or touring system. A few examples are provided below:
Matrix Output Expansion
DME64N/24N Audio System Overview
Particularly in concert situations there always seems to be a need for more feeds and outputs. The DME64N/
24N can function as an extremely versatile output matrix/router system that can be easily reconfigured to meet
changing system requirements.
Matrix Outputs
(to stage monitors,
clusters, recording
feeds, etc.)
Audio
Signals
Input
Output
Mix Outputs
(F.O.H, etc.)
(Mic/Line, etc.)
Power Amplifiers,
Speakers
DME64N/24N
Outboard Signal Processing
A single DME64N/24N can replace racks of standard outboard processing and effects gear.
Send
L
Input
• Compressor
• Reverb
• Delay
• Equalizer
R
Audio
Signals
L
Output
R
Return
DME64N/24N
Mixer
Output Processor
Multi-band output processing is just one of the many output processing functions the DME64N/24N could
be applied to. A single DME64N can handle up to 64 channels, while a DME24N can handle up to 24
channels, for extraordinary capacity and versatility.
High
band
Audio
Signals
Input
Mid
Band
Low
Band
DME64N/24N
Output
High Band Power Amp
Tweeter
Mid Band Power Amp
Midrange
Low Band Power Amp
Woofer
Power Amps
Speakers
DME64N/24N Owner’s Manual
9
System Examples
System Examples
Single DME24N: A Meeting Room Installation
Here’s an example of a single DME24N used to control the sound in four partitionable regions. The built-in
microphone preamplifiers and A/D converters allow direct connection of up to 8 microphone inputs, while the
8 analog outputs can directly feed four stereo power amplifiers. Scenes can be set up to handle any of the
possible partition configurations, allowing background music and microphone sources to be handled as
required by each configuration.
In this example an ICP1 Intelligent Control Panel is installed in one region to allow scene recall and parameter
control. Other regions have a 1-fader 1-switch CP1SF control panels to allow users to adjust microphone and
background music levels.
CD Player
For Region A
For Region B
DME64N/24N Audio System Overview
MY8-AD
DME24N
1~8
CAT5
1~8
GPI
XM4220
Power Amplifier
CP1SF
Control Panel
10
0
Speakers (L)
ICP1
Intelligent
Control Panel
Speakers (R)
Mics
Speakers (L)
Speakers (R)
Mics
Region A-1
Region B-1
Region A-2
Region B-2
CP1SF
Control Panel
CP1SF
Speakers (L)
Speakers (R)
Speakers (L)
10
0
10
DME64N/24N Owner’s Manual
Speakers (R)
Control Panel
10
Mics
Mics
0
System Examples
Multiple DME64N: Large Stadium Or Multi-purpose Hall System
In this system live audio from microphones is mixed with background music and other sources in the central
control room using a Yamaha DM1000 digital mixing console. A DM1000 equipped with an MY16-AE
digital I/O card and an NHB32-C network hub bridge can feed the control room output to the system’s
DME64N units over distances of up to 2 kilometers via multimode optical fiber cables. The control room also
houses the system-control computer running the DME Designer application software, and an ICP1 Intelligent
Control Panel for general DME unit control. The audio and control signals from the control room are
distributed to four amp rooms (zones) via the CobraNet Ethernet cable. One or more DME64N units in each
amp room handles signal routing and output processing (equalization, limiting, crossover) and the resultant
digital output is converted to analog audio and fed to the power amplifiers via ACU16-C Amplifier Control
Units. Scene switching to accommodate a variety of spectator/audience seating areas for different types of
events can be handled from both the control-room PC and ICP1 control panel.
Amp Room 1
ACU16-C
Amp Control Unit
Ethernet MY16-C
Switch
DME64N/24N Audio System Overview
(RS485)
DME64N
(Gigabit)
Cascade
MY16-C
DME64N
Amp Room 2
PC-N Series
ACU16-C
Amp Control Unit
(RS485)
Control Room
Ethernet MY16-C
Switch
DME64N
(Gigabit)
Cascade
Mics
MY16-C
NHB32-C
Network Hub/Bridge
CD Player
(Gigabit)
MY16-AE
Amp
Monitoring
DME64N
Ethernet
Switch
Amp Room 3
PC-N Series
ACU16-C
Amp Control Unit
(USB)
(RS485)
DME-N Control
DM1000 Digital Mixer
PC
Ethernet MY16-C
Switch
ICP1
DME64N
(Gigabit)
Cascade
Intelligent
Control Panel
MY16-C
DME64N
Amp Room 4
PC-N Series
ACU16-C
Amp Control Unit
(RS485)
CobraNet Audio
Amp Monitoring
DME-N Control
Ethernet
Switch
MY16-C
DME64N
(Gigabit)
Cascade
MY16-C
DME64N
PC-N Series
DME64N/24N Owner’s Manual
11
System Examples
Single DME64N: Sound Reinforcement
For live sound reinforcement applications a DME64N can be connected to a Yamaha PM5D digital mixing
console, for example, to provide significantly expanded processing power. In this type of application the
DME64N could be used to provide up to an additional 64 matrix outs as well as output processing such as
GEQs, level controls, crossovers, delays, and more. The DME-to-console connection can be made either the
cascade connector.
68-pin Half-pitch D-SUB Cable
CASCADE OUT
CASCADE IN
DME64N/24N Audio System Overview
PM5D
12
DME64N/24N Owner’s Manual
DME64N
DME64N/24N Audio System Network
DME64N/24N Audio System Network
To facilitate understanding and conceptualizing an overall DME64N/24N system, the terms “area” and “zone” are applied.
The entire area serviced by the system is the “area,” while audio processing divisions within the area are “zones.” A single
computer can be used to control the entire area as well as individual zones in a DME64N/24N audio system.
Up to 16 DME64N/24N units can operate in any one zone. DME64N/24N units in each zone are interconnected and
function as a single system.
Each zone always includes one DME64N/24N, which functions as the “zone master” and controls all other DME64N/24N
and ICP1 units (zone slaves) in the same zone. If a computer is connected to the zone master, the computer can be used to
control all devices in the zones.
DME64N/24N Audio System Overview
Area
Zone
Area
Zone
Zone
DME64N
DME64N
Switching
Hub
Switching
Hub
DME64N
DME64N
DME64N
DME64N
DME64N
Computer
DME64N
Router
Computer
Zone
Zone
DME64N
DME64N
DME64N
DME64N
ICP1
ICP1
Switching
Hub
DME64N
Switching
Hub
DME64N
DME64N
DME64N
DME64N/24N Owner’s Manual
13
DME64N/24N Audio System Control
DME64N/24N Audio System Control
To facilitate understanding and controlling an overall DME64N/24N system, the terms “component,” “parameter,” “scene,”
and “user-defined parameter” are applied.
Components & Parameters
The individual audio modules (equalizers, compressors, etc.) are called “components.” Head amplifier modules
are also prepared as components. Changing the parameters of components enables control over the operation
of the components.
Configurations
A “configuration” is a complete set of components for constructing an audio system. Each configuration
determines the audio function(s) of the corresponding DME64N/24N unit. All parameter sets included with
each component are called “preset parameters.” One DME64N/24N unit has a number of configurations, and
a configuration has a number of preset parameters.
DME64N/24N Audio System Overview
User-defined Parameters
By assigning a parameter to a user-defined parameter, the user-defined parameter can be controlled from the
panels of the DME64N/24N and ICP1, or other controllers connected via MIDI or GPI. Multiple parameters
assigned to a single user-defined parameter will be controlled simultaneously. Up to 24 user-defined parameters
can be used in a zone.
Scenes
A combination of all configuration and preset parameter combinations is called a “scene.” A scene determines
the audio effect(s) in the zone. Scenes can be recalled from the panels of the DME64N/24N and ICP1, other
controllers connected via MIDI or GPI, or computer control. Up to 999 scenes can be stored for each zone.
N OT E
Slight delays might be experienced when switching scenes or editing user-defined parameters, depending on the network
condition.
Scene Structure
Scene
Configuration
MATRIX MIXER
Scene 1
Scene 2
COMP/LIMITER PARAMETRIC EQ
DELAY
2WAY
CROSSOVER
8 BAND
COMP/LIMITER PARAMETRIC EQ
DELAY
2WAY
CROSSOVER
Preset
Parameters
DELAY
PARAMETRIC EQ COMP/LIMITER
GATE
DELAY
PARAMETRIC EQ COMP/LIMITER
GATE
DELAY
PARAMETRIC EQ COMP/LIMITER
GATE
DELAY
PARAMETRIC EQ COMP/LIMITER
GATE
16 x 8
Scene 999
= Component
Scene Change
First Act
Stage Lights Down
Second Act
Band Setup
Band
Setup
Theater
Setup
Theater Setup
Stage
Stage
Stage
Scene 1
Scene Recall
Scene 2
Theater Setup
14
DME64N/24N Owner’s Manual
Band Setup
Example:
Gate
• Attack
• Decay
• Range
• Threshold
• Key In
• Hold
:
:
DME Designer
DME Designer
The DME Designer software application, supplied with the DME64N/24N, can be used to create configurations as well as
control the entire area.
DME64N/24N Audio System Overview
A DME64N/24N network system cannot be set up entirely from the DME64N/24N alone. Configurations and scene data
must be created on a computer running the DME Designer application, and then transferred from the computer to the
DME64N/24N. The DME Designer can also be used to determine how external controllers will control DME64N/24N
parameters.
Refer to the DME Designer Installation Guide for detailed information on connecting a computer to the DME64N/24N and
installing the required software drivers.
Refer to the DME Designer Owner’s Manual for setup and operation instructions. The PDF manual will automatically be
copied to the computer when the DME Designer application is installed.
DME64N/24N Owner’s Manual
15
Front Panel
The Controls and Connectors
Front Panel
DME64N
!
1
@
SCENE
#
HOME
2
^
)
9
$
UTILITY
*
%
LEVEL
º
¡
™
(
CANCEL
MUTE
&
£
ENTER
4
5
6
3
The Controls and Connectors
DME24N
^
)
9
&
1
!
@
SCENE
2
3
4
5
6
#
HOME
$
UTILITY
*
%
LEVEL
MUTE
™
(
CANCEL
º
¡
£
ENTER
7
8
7
8
1 [USB] Connector
A computer can be connected here when it is necessary to
program or control the device. When a USB connection is
to be used, the USB-MIDI driver must be installed on the
computer. Refer to the DME Designer Installation Guide
for installation instructions.
2 [EXT. CLOCK] Indicator
When a clock signal from an external device is selected, the
indicator will light green. If the clock signal is not
appropriate the indicator will flash red. The indicator will
go out when the internal word clock is selected.
3 [96kHz] [88.2kHz] [48kHz] [44.1kHz]
Indicator
Normally, the indicator corresponding to the current word
clock frequency will light green. If a problem with the
master clock is detected all of these indicators will flash red.
2 seconds after a problem is detected with an external
master clock the internal clock will temporarily be selected.
When this happens the indicator corresponding to the
frequency of the internal clock will light green, and all
other indicators will continue to flash red.
4 [NETWORK] Indicator
Lights while data communication is occurring via the
[USB], [NETWORK], or [CASCADE] connector.
Received data causes the indicator to light in green, while
transmitted data causes the indicator to light in orange. If a
problem occurs the indicator will light in red.
16
DME64N/24N Owner’s Manual
Front Panel
5 [MIDI] Indicator
# [UTILITY] Button
Lights while data communication is occurring via the
[MIDI] connector. Received data causes the indicator to
light green, while transmitted data causes the indicator to
light orange. The indicator will light green when reception
and transmission occur simultaneously. If a problem occurs
the indicator will light red.
Calls the output level display. If this button is held for
longer than 2 seconds while the main display is showing
the utility display will appear. Switches between the Utility
display pages if pressed while the Utility display is showing.
Lights green when the device is operating as the zone
master (page 13). The indicator will not light if the device
is operating as a zone slave. Refer to page 48 for zone
master setup instructions.
7 [PEAK] Indicator (DME24N only)
Calls the output level setup display (page 46).
The indicator will light green.
% [MUTE] Button
Calls the mute display (page 42). The indicator will light
orange when mute is on. The indicator will light green
when mute is off and the mute display is showing, and will
be off if the mute display is not showing.
Light red when a signal on the corresponding built-in
analog audio input or output ([IN] and [OUT]
connectors) reaches or exceeds -3 dB.
^ Dial
8 [SIGNAL] Indicator (DME24N only)
& [E] [ ▲ ] [ ▼ ] [F] Buttons
Light green when a signal with a level greater than -40 dB
is present at the built-in analog audio inputs and outputs
([IN] and [OUT] connectors).
Move the display cursor in the corresponding directions.
NO T E
The DME64N has no built-in analog audio inputs or outputs
([IN] and [OUT] connectors).
Adjusts the value of selected parameters.
The Controls and Connectors
6 [MASTER] Indicator
$ [LEVEL] Button
* [CANCEL] Button
Closes the window on the display.
( [ENTER] Button
Confirms and enters a value or setting.
9 [SCENE NUMBER] Indicator
Shows the current scene number.
) Display
Displays scene information and device parameters.
! [SCENE] Button
Calls the scene recall/store display (page 43). The scene
store display will appear if the button is held for longer
than 2 seconds (page 43). The indicator will light green
while the scene recall or store display is showing.
@ [HOME] Button
Directly recalls the home (main) display. If pressed while
the main display is showing the [HOME] button steps
through the user-defined parameter display pages (refer to
page 42 in this manual).
º [PHONES] Jack
A pair of headphones can be plugged in here.
¡ [PHONES LEVEL] Control
Adjusts the headphone volume. Even when the control is
set to the minimum level, the sound at the headphones is
not completely muted.
™ [MONITOR] Button
Calls the monitoring point slot selection display (page 44).
When the [ENTER] button is pressed to select a slot, the
monitoring point selection display will appear.
The spectrum analyzer display will then appear when the
[ENTER] button is pressed to select a monitoring point.
The indicator will light green while the monitoring slot/
point or spectrum analyzer display is showing.
£ [POWER] Switch
Turns mains power to the device on and off.
DME64N/24N Owner’s Manual
17
Rear Panel
Rear Panel
4
DME64N
1 2
6
7
)
9
3
DME24N
5
4
3
The Controls and Connectors
1 2
9
1 [AC IN] Connector
This is the device’s three-pronged AC power connector.
Connect to the AC mains using the supplied AC power
cord. See “Preparation” on page 20 for details.
6
7
5
8
NOTE
Connect the device to only one ground point.
Connecting the device to more than ground point can result in
ground loops that can cause increased hum and noise.
NO T E
Use the supplied AC cord clamp to prevent accidental
disconnection of the AC power.
NO T E
When connecting to two-prong type AC mains outlets use the
supplied plug adaptor.
2 Ground Screw
The supplied power cable has a three-prong plug that will
ground the unit when plugged into an appropriate threeprong type AC mains outlet. When connecting to a twoprong type outlet that has a ground screw, use the supplied
AC plug adaptor and connect the adaptor’s ground lead to
the ground screw. When connecting to a two-prong type
outlet that does not have a ground screw be sure to connect
the DME64N/24N ground screw to a confirmed ground
point. Proper grounding can significantly reduce hum,
noise, and interference, while stabilizing phase and
imaging.
NO T E
Make sure that the device is securely grounded to a single ground
point (e.g. either via a three-prong AC connection, or via the
ground screw.)
18
DME64N/24N Owner’s Manual
3 [GPI] Connector
This Euroblock connector provides access to the unit’s GPI
(General Purpose Interface) interface for transfer of control
signals to and from external equipment. The DME64N
provides 16 channels of GPI input and output, while the
DME24N provides 8 channels. Each input channel has an
IN terminal and a +V terminal. Output channels each have
an OUT terminal and a GND terminal. The open voltage
at the +V terminal is 5V, while the IN terminal detects
voltage changes from 0V ~ 5V. The OUT terminals output
either 0V or 5V. See “GPI Connection” on page 31 for
connection details.
Rear Panel
4 [MIDI IN] [MIDI OUT] [MIDI THRU]
Connectors
These are standard MIDI connectors that handle reception
and transmission of MIDI data: [MIDI IN] receives MIDI
data, [MIDI OUT] transmits MIDI data, and [MIDI
THRU] re-transmits MIDI data received at the [MIDI
IN] connector. See “MIDI Connection” on page 30 for
connection details.
5 [WORD CLOCK IN] [WORD CLOCK OUT]
Connectors
These BNC connector receive and transmit word clock
from and to external equipment. See “Word Clock
Connection” on page 33 for connection details. Word
clock settings are available via the device’s Utility display
WCLK page (see page 51 of this document).
9 I/O Slots
Optional Yamaha or third-party mini-YGDAI cards can be
plugged in here for system expansion. The DME64N has
four I/O slots, while the DME24N has one.
One expansion card can be plugged into each slot. Refer to
“I/O Card Installation” on page 22 for installation details.
) [CASCADE IN] [CASCADE OUT]
Connectors (DME64N only)
This 68-pin D-SUB connector can be connected to the
CASCADE connector of other devices via a dedicated
cascade cable. The CASCADE connector transmits and
receives control, audio, and word clock signals. Refer to
“Cascade Connection” on page 32 for connection details.
6 [NETWORK] Connector
The Controls and Connectors
This is a 100Base-TX/10Base-T Ethernet connector for
connection to a computer or other DME64N/24N units.
Normally this connector will be connected to a network
hub via an Ethernet “straight” cable. When two
DME64N/24N units are to be directly connected a “cross”
cable should be used.
7 [REMOTE] Connector
This 9-pin D-SUB connector allows connection to
Yamaha AD824 or AD8HR remote head amplifiers or
other RS-232C compatible controllers. Refer to page 34
for connection details.
8 [IN] [OUT] Connectors (DME24N only)
These are balanced Euroblock connectors for analog audio
input and output. The analog signal from microphones or
line sources such as CD players can be input via the IN
connectors, while the OUT connectors can deliver analog
output to powered speakers or recording equipment. 48V
phantom power can be supplied to the IN connectors
(page 54). Refer to page 35 for [IN] and [OUT]
connection details.
NO T E
The [IN] and [OUT] connectors each have 24 terminal pins.
Each of the eight inputs and outputs uses three pins – hot, cold,
and ground. Use the supplied 3-pin Euroblock plugs to connect
to the appropriate inputs and outputs.
DME64N/24N Owner’s Manual
19
Setup Procedure
Preparation
Setup Procedure
Follow the steps outlined below to prepare the DME64N/24N for operation.
1. Install any required I/O cards.
Refer to “I/O Card Installation” on page 22 for details.
2. Connect the AC power cord.
CAUTION
Be sure to turn all devices OFF before connecting AC mains power.
Attach the cable clamp to prevent accidental disconnection.
Attaching the cable clamp.
Preparation
Be sure to properly ground the device to prevent possible electrical shock.
First plug the female-connector end of the AC cord into the [AC IN] socket on the rear panel of the
DME64N/24N, then plug the male plug into an appropriate AC mains outlet. Make sure the AC power to be
used complies with the conditions marked on the top cover of the device.
WARNING
Use only the AC power cord supplied with the DME64N/24N. If the supplied cord is lost or damaged ands needs
to be replaced, contact your Yamaha dealer. The use of an inappropriate replacement can pose a fire and shock
hazard!
The type of AC power cord provided with the DME64N/24N may be different depending on the country in which
it is purchased (a third prong may be provided for grounding purposes). Improper connection of the grounding
conductor can create the risk of electrical shock. Do NOT modify the plug provided with the DME64N/24N. If the
plug will not fit the outlet, have a proper outlet installed by a qualified electrician. Do not use a plug adapter which
defeats the grounding conductor.
Security Cover Mounting
Security cover mounting screw holes (M3 size) are provided on the front panel of the unit. The spacings are
423mm width and 96mm (DME64N) / 52mm (DME24N) height. See “Dimensions” on page 68 for
details. A security cover made by the customer or contractor can be attached to the front panel via these
mounting holes to prevent accidental operation. Yamaha cannot supply a security cover.
When mounting a cover make sure that the screws used do not go deeper than 15 millimeters into the front
panel. Also, to ensure that the cover does not come in contact with the panel controls, leave a space of about
20 millimeters between the front panel and the cover.
20
DME64N/24N Owner’s Manual
Setup Procedure
3. Install the DME Designer software and necessary drivers on the computer to be used for
zone control.
See the separate “DME Designer Installation Guide” for details.
4. Connect the device to the computer and/or other equipment.
Refer to “Connection” on page 24 for details.
5. Turn power to the computer, DME64N/24N, and related devices on. Press the DME64N/24N
[POWER] switch to turn it on.
CAUTION
To prevent the initial power-on surge from generating a large noise spike or damaging your speaker system, turn
devices on in the following order: audio sources, mixer and/or recorders, and finally power amplifiers. Reverse this
order when turning power off.
Preparation
No information will appear on the display the first time the device is turned on. The appropriate scene and
other data must first be transferred to the device from the DME Designer.
Once the appropriate data has been transferred to the device, the current number and name will appear on the
display:
If any scene data has been stored in the DME64N/24N, the current scene and its name will be displayed.
6. Set up the DME64N/24N operation parameters.
See the “Utility Display” section on page 47 for details.
N OT E
The “NET” page settings must be set up as required before using the unit for the first time.
7. Launch the DME Designer application on the computer.
DME Designer setup, operation, and data transfer instructions can be found in the DME Designer Manual.
This completes preparation of the DME64N/24N system.
DME64N/24N Owner’s Manual
21
I/O Card Installation
I/O Card Installation
The DME64N has four I/O card slots, and the DME24N has one I/O card slot. The number of audio input channels
available on the DME64N/24N can be increased by plugging the appropriate mini-YGDAI I/O card(s) into the available card
slot(s).
Compatible I/O Cards
As of July 2004, Yamaha mini-YGDAI cards that can be used with the DME64N/24N are as follows:
Card Name
Function
Input
Output
No. of Available Cards
DME64N
DME24N
MY8-AT
ADAT
8
8
4
1
MY8-TD
TDIF-1
8
8
4
1
MY8-AE
AES/EBU
8
8
4
1
MY4-AD
ANALOG IN
4
–
4
1
MY8-AD
ANALOG IN
8
–
4
1
MY4-DA
ANALOG OUT
–
4
4
1
MY8-AD24
ANALOG IN
8
–
4
1
MY8-AD96
ANALOG IN
8
–
4
1
MY8-DA96
ANALOG OUT
–
8
4
1
Preparation
MY8-AE96S
AES/EBU
8
8
4
1
MY8-AE96
AES/EBU
8
8
4
1
MY16-AT
ADAT
16
16
4
1
MY16-AE
AES/EBU
16
16
4
1
MY16-TD
TDIF-1
16
16
4
1
MY16-C
CobraNet
16
16
2
1
The input/output numbers above apply to 44.1/48kHz operation.
For the latest information on what cards can be used with the DME64N/24N, visit the Yamaha Pro Audio
website at: http://www.yamahaproaudio.com/
22
DME64N/24N Owner’s Manual
I/O Card Installation
I/O Card Installation Procedure
1. Make sure that the DME64N/24N power is OFF.
If the power is on, turn it off.
2. Loosen the two card slot screws and remove the slot cover, as shown in the diagram.
N OT E
Preparation
The slot cover and screws will need to be re-attached if the I/O card is later removed from the slot, so keep them in a safe place.
3. Slide the I/O card into the slots in the guide rails, as shown in the diagram, and push the
card into the slot.
Be sure to push the card all the way back into the slot so that the card contacts make proper contact with the
slot connector.
Guide Rail
4. Secure the card with the attached screws.
CAUTION
Be sure to tighten the screws securely. If the screws are left loose proper contact may be lost and malfunction of
damage may result.
DME64N/24N Owner’s Manual
23
Connection
Connection
The DME64N/24N must be connected to other DME64N/24N units as well as other audio equipment, according to the
audio system design.
Signal Types
DME64N/24N audio system signals can be broadly categorized as follows.
1. Audio
The DME64N/24N will be required to send and receive audio signals to and from other DME64N/24N units as
well as other audio equipment. Audio signal transmission and reception will occur primarily via I/O cards installed in
the unit’s I/O card slot(s). The DME24N has 8 channels of built-in audio I/O that can be used without installing
any extra cards.
2. Zone Control
Zone control signals control all DME64N/24N units and ICP1 control panels within the zone. There are two types
of zone control signals, as follows:
• Signals for communication between the computer or mixer that controls the entire area and the zone master
DME64N/24N.
• Signals for communication between the zone master DME64N/24N and other DME64N/24N within the zone.
The DME Designer application running on the area-control computer is used to send components and set
parameters as required.
3. Device Control
Preparation
These signals provide communication and control between individual devices. Included in this category are MIDI
messages transferred between [USB] and [MIDI] connectors, GPI signals transferred between [GPI] connectors, and
remote head amp control signals handle via the [REMOTE] connector.
4. Word Clock
Individual devices that handle the same digital audio signals must be synchronized to a single word clock of the same
frequency. The DME64N/24N transmits and receives word clock via the [CASCADE IN] and [CASCADE OUT]
connectors, the [WORD CLOCK IN] and [WORD CLOCK OUT] connectors, and via I/O cards plugged into the
I/O card slots.
DME64N/24N Signal Types
Connector
24
Audio Signal
Zone Control
Device Control
Word Clock
Page
USB Connection
[USB] Connector
–
–
Control signals from computer Transmission/reception of
to zone master DME64N/24N. control signals (MIDI
commands) between computer
and DME64N/24N.
Page 26
Ethernet
Connection
[NETWORK]
Connector
–
–
Control signals between
computer and zone master, and
between zone master and other
DME64N/24N units in the
zone.
–
Page 27
MIDI Connection [MIDI] Connector
–
–
Transmission/reception of
control signals (MIDI
commands) between MIDI
controller and DME64N/24N.
–
Page 30
GPI Connection
[GPI] Connector
–
–
Transmission/reception of GPI –
control signals between GPI
device (GPI controller, etc.)
and DME64N/24N.
Page 31
CASCADE
Connection
(DME64N only)
[CASCADE]
Connector
32 channels of
input/output.
Control signals from mixer to
zone master DME64N/24N.
–
Word clock transmission and
reception to and from other
devices.
Page 32
WORD CLOCK
Connection
[WORD CLOCK]
Connector
–
–
–
Word clock transmission and
reception to and from other
devices.
Page 33
REMOTE
Connection
[REMOTE]
Connector
–
–
Control signal transmission
–
and reception to and from head
amplifier.
Page 34
Audio I/O
(DME24N only)
(Audio I/O
Connectors)
8 channels of input –
and output.
–
–
Page 35
I/O Card
(I/O Slot)
Number of I/O
channels depends
on card.
Serial signal transmission/
reception (depending on
function of card).
Word clock transmission and
reception to and from other
devices (depending on
function of card).
Page 37
DME64N/24N Owner’s Manual
–
Connection
Other Zone
Other Zone
Zone
ICP1
Switching Hub
Router
Computer
GPI Controller
(CP4SW/CP4SF/CP1SF)
DME64N/24N
DME64N/24N
Matrix
Output Processor
Preparation
Audio Signals
(Power Amp,
Recorder, etc.)
Audio Signals
(Microphone,
CD Player, etc.)
Audio Signals
(Power Amp,
Recorder, etc.)
DME64N/24N
Output Processor
: Audio
: Zone Control
: Device Control
: Word Clock
Word Clock Master
DME64N/24N Owner’s Manual
25
Connection
USB Connection
Connect the DME64N/24N [USB] connector to the computer’s USB connector using a USB cable.
USB connections can be used in the following two ways:
(1) Connect the computer to, and control the zone master DME64N/24N using the DME Designer.
(2) Connect to any individual DME64N/24N and control that DME64N/24N unit using MIDI commands
from a MIDI sequencer or similar software.
DME Designer can be used for overall zone control, as well as sending components to the zone via the zone
master.
When using MIDI commands from a MIDI sequencer to directly control a DME64N/24N, HOST (see page
52) should be set to USB-1 or USB-2.
N OT E
The correspondence between the MIDI commands to be received/transmitted and the scene parameters can be set up using
the DME Designer.
N OT E
The USB port being used by the DME Designer cannot also be used by a MIDI sequencer or other application.
N OT E
When connecting a computer to a DME64N/24N via USB, the appropriate USB-MIDI driver must be installed on the
computer. Refer to the DME Designer Installation Guide for details on installing the appropriate driver.
Make sure that the USB-MIDI driver THRU setting is “OFF.”
Preparation
Zone
Zone Master
DME64N/24N
USB Cable
In the case of (1), above
Ethernet Straight Cable
Switching Hub
Ethernet Straight Cable
DME64N/24N
Ethernet
Straight Cable
DME64N/24N
USB Cable
In the case of (2), above
26
DME64N/24N Owner’s Manual
Computer
(DME Designer operation)
Computer
(MIDI sequencer or
similar operation)
Connection
Ethernet Connection ([NETWORK] Connector)
Connect the [NETWORK] connector on the rear panel of the DME64N/24N to the network switching hub
via a straight Ethernet cable.
Ethernet connections can be used in the following two ways:
• Connect the computer to the zone master DME64N/24N.
• Connect the zone master DME64N/24N to zone slave DME64N/24N units.
Appropriate IP addresses must be assigned to all devices connected to an Ethernet network. Refer to the Utility
display Net page (page 48 of this document) for IP address setting details.
N OT E
When connecting a computer to a DME64N/24N via Ethernet, the appropriate DME-N Network driver must be installed on
the computer. Refer to the DME Designer Installation Guide for details on installing the appropriate driver.
A DME64N/24N Ethernet connection falls into the “Class C Network” category. In a class C network, of the
assignable IP addresses “###.###.###.$$$”, “###.###.###” is the network address and “$$$” is the host
address. Devices assigned the same network address will function within the same zone. The host address range
is 2 ~ 254. When the host address is “2” the device is the zone master, while host addresses from 3 to 254 are
assigned to zone slaves. Only one zone master can be assigned in any one zone.
Preparation
Devices in the same zone (devices having the same network address) can be directly connected using cross
cables, or by using straight cables via a switching hub.
Devices in different zones (devices having different network addresses) can be connected via a router or layer-3
compliant switching hub.
DME64N/24N Units Directly Connected via Ethernet
Ethernet Cross Cable
DME64N/24N
DME64N/24N
N OT E
A cross cable can be used to directly connect DME64N/24N and/or ICP1 units. In such cases set the Link Mode parameters
in the network settings pages of both units the same way (page 49 of this document).
DME64N/24N Owner’s Manual
27
Connection
Control from a Computer Having the Same Network Address
Zone
Zone Master
DME64N/24N (IP Address: 192.168.0.2)
Ethernet Straight Cable
Ethernet
Straight Cable
Switching Hub
Ethernet Straight Cable
Ethernet
Straight Cable
Computer
(IP Address: 192.168.0.100)
DME64N/24N
DME64N/24N
(IP Address: 192.168.0.3)
(IP Address: 192.168.0.250)
N OT E
The IP addresses in the diagram are examples.
Preparation
N OT E
Use a switching hub that is compatible with 100Base-TX/10Base-T network speeds.
When using category 5 UTP cable (Unshielded Twisted Pair), the total length of the cables connecting the DME64N/24N to
the hub or control panel unit can be up to 100 meters. Due to differences in cable and switching hub performance, however,
proper operation at the maximum length cannot be guaranteed in some cases. The maximum usable cable length will also be
reduced if joint connectors, cross cable converters, or other extension adaptors are used.
Control from a Computer Having a Different Network Address
Zone
Zone Master
Port Settings
DME64N/24N (IP Address: 192.168.0.2)
• Destination network address: 192.168.0.0
• Subnet mask: 255.255.255.0
• Gateway: 192.168.0.1
Ethernet Straight Cable
Switching Hub
Ethernet
Straight Cable
28
Ethernet
Straight Cable
Ethernet
Straight Cable
DME64N/24N
DME64N/24N
(IP Address: 192.168.0.3)
(IP Address: 192.168.0.12)
DME64N/24N Owner’s Manual
Router
Ethernet
Straight Cable
Computer
Connection
Connecting Multiple Zones
Port Settings
Port Settings
• Destination network address: 192.168.0.0
• Subnet mask: 255.255.255.0
• Gateway: 192.168.0.1
• Destination network address: 192.168.1.0
• Subnet mask: 255.255.255.0
• Gateway: 192.168.1.1
Zone
Zone
Zone Master
Zone Master
DME64N/24N (IP Address: 192.168.0.2)
DME64N/24N (IP Address: 192.168.1.2)
Ethernet Straight Cable
Switching Hub
Ethernet
Straight Cable
Ethernet
Straight Cable
DME64N/24N
DME64N/24N
(IP Address: 192.168.0.40)
(IP Address: 192.168.0.100)
Router
Ethernet Straight Cable
Ethernet
Straight Cable
Ethernet
Straight Cable
Switching Hub
Ethernet
Straight Cable
Ethernet
Straight Cable
DME64N/24N
DME64N/24N
(IP Address: 192.168.1.10)
(IP Address: 192.168.1.200)
Preparation
Ethernet Straight Cable
Computer
(IP Address: 192.168.10.5)
DME64N/24N Owner’s Manual
29
Connection
MIDI Connection
In this case connection is made to the rear-panel [MIDI] connectors. MIDI commands are sent to the
DME64N/24N from a MIDI device.
N OT E
Refer to “MIDI Page” on page 52 for MIDI setup details.
N OT E
The DME Designer can be used to set up the system so that scene recall operations and user parameter control can be carried
out from connected MIDI devices. Refer to the DME Designer manual for details.
By connecting the [MIDI OUT] terminal of a digital mixer (such as the DM2000) to the [MIDI OUT] of the
DME64N/24N and making the proper settings on the mixer and the DME64N/24N, you can change scenes
by sending program change messages from the mixer.
MIDI Cable
MIDI OUT
MIDI IN
DME64N/24N
Preparation
DM2000 Digital Mixer or Other Controller
If the [MIDI OUT] connector of the DME64N/24N is connected to the [MIDI IN] connector of an
SPX2000 or similar digital effect unit, and if the DME64N/24N and SPX2000 are set up appropriately,
DME64N/24N program change operations will case the corresponding effect to be recalled on the effect unit.
MIDI Cable
MIDI OUT
MIDI IN
SPX2000 or Other Digital Effect Unit
DME64N/24N
30
DME64N/24N Owner’s Manual
Connection
GPI Connection
GPI (General Purpose Interface) device (GPI controller, etc.) can be connected to the rear-panel [GPI]
connectors. Using GPI a variety of control signals can be transferred between the DME64N/24N and external
controllers or other devices. The optional CP4SW, CP4SF, and CP1SF control panels are also connected via
GPI.
N OT E
For more information on the CP4SW, CP4SF, and CP1SF control panels refer to “CP4SW, CP4SF, and CP1SF” in the
Appendix of this manual (page 59).
The DME64N provides 16 channels of GPI input and output, and the DME24N provides 8 channels. Each
input channel has an IN terminal and a +V terminal. Each output channel has an OUT terminal and a GND
terminal. The +V terminals have an open-terminal voltage of 5 volts. The IN terminals can detect a full range
of input voltages from 0V through 5V, while the OUT terminals output either 0V or 5V.
The parameters for each GPI input and output are assigned via the DME Designer application.
N OT E
The DME Designer can be used to set up the system so that scene recall operations and user parameter control can be carried
out from connected GPI control devices. Refer to the DME Designer manual for details.
Example: Controlling the
DME64N/24N from a switch.
Example: Controlling the
DME64N/24N via a 10k ohm
linear taper potentiometer.
IN
Example: Lighting external
LED indicators from the
DME64N/24N.
GPI Connection
GPI Connection
GPI Connection
IN
+V
+V
Preparation
Euroblock connectors are used for all GPI input and output connections. Euroblock connection methods are
described in “Euroblock Connection” on page 35 in this manual.
OUT
GND
GND
GPI Connector
Trigger Voltages
OUT GND
OUT
GND
Max. 6mA
Continuous
potentiometer
CAUTION
DME64N/24N [GIP] Connector
DME64N/24N [GPI] Connector
8
IN
7
6
5
4
3
2
1
8
+V
IN
Euroblock plug
Remote Switch Box
7
6
5
4
3
2
3
2
Switch
1
(High)
Make sure that the current between
the OUT and GND [GPI] connectors
is less than 6mA.
8
+V
Remote Switch Box
+5 V
(Low)
DME64N/24N [GPI] Connector
1
7
6
5
4
3
2
1
OUT GND
Euroblock plug
4
0V
Euroblock plug
4
3
2
1
10k ohm linear taper
potentiometer
Remote Switch Box
4
3
2
1
LED indicator and
resistor
N OT E
GPI connector calibration procedure is described on page 53 of this manual, in the Utility display GPI page.
DME64N/24N Owner’s Manual
31
Connection
CASCADE Connection (DME64N only)
The rear-panel [CASCADE] connector can be connected to the [CASCADE] connector on another
DME64N/24N or other compatible device via a dedicated cascade cable for bidirectional transfer of control,
audio, and word clock signals. The communication direction automatically switches to unidirectional when
connecting to a mixer such as the PM5D, or bidirectional when connecting to another DME64N/24N unit.
In the unidirectional mode the audio signal flow is from the [CASCADE OUT] connector to the [CASCADE
IN] connector. In the bidirectional mode signal flow also occurs in the reverse direction via the same cable. The
total number of audio channels that can be connected to a mixer or DME64N/24N unit is 32.
Word clock is continuously output from both the [CASCADE IN] and [CASCADE OUT] connectors, and is
received by the corresponding [CASCADE IN] or [CASCADE OUT] connector on the connected device.
In all cases the [CASCADE OUT] of one device must be connected to the [CASCADE IN] connector of the
other. Do not connect [CASCADE IN] to [CASCADE IN], or [CASCADE OUT] to [CASCADE OUT].
N OT E
Maximum length by the optional dedicated Cascade cables
Unidirectional Cascade connection: 200m (44.1/48kHz), 100m (88.2/96kHz)
Bidirectional Cascade connection: 100m (44.1/48kHz), 30m (88.2/96kHz)
Cascade Connection Example
Unidirectional Cascade Connection
68-pin Half-pitch D-SUB Cable
IN
OUT
Preparation
DME64N
Bidirectional Cascade Connection
DME64N
68-pin Half-pitch D-SUB Cable
IN
OUT
68-pin Half-pitch
D-SUB Cable
IN
PM5D
68-pin Half-pitch
D-SUB Cable
OUT
DME64N
N OT E
Never create a full cascade loop using only DME64N units!
32
DME64N/24N Owner’s Manual
IN
DME64N
OUT
Connection
WORD CLOCK Connection
Word clock signals are transferred to and from external devices via the [WORD CLOCK IN] and [WORD
CLOCK OUT] connectors. The [WORD CLOCK OUT] connector can be used to supply the DME64N/
24N word clock to external equipment. Word clock is continuously output by the DME64N/24N during
normal operation. The word clock signal from an external device can be received via the [WORD CLOCK IN]
connector.
N OT E
Word clock can also be received and transmitted via a mini-YGDAI card installed in an I/O slot, or the [CASCADE IN] and
[CASCADE OUT] connectors. It is necessary to specify whether the DME64N/24N will use the internal word clock or an
external word clock for synchronization. Refer to the Utility display WCLK page described on page 51 of this manual for
details.
N OT E
A device transmitting the word clock signal that will be used by other devices for synchronization is the “word clock master,”
while devices received the word clock are “word clock slaves.”
WC OUT
(BNC)
WC IN
(BNC)
Word Clock
Master
DME64N/24N
Preparation
Word Clock Slave
To distribute the word clock signal from one device to multiple slave devices, either a word clock distribution
box or daisy-chained connection can be used.
Distribution Box Connection
Word Clock
Master
WC OUT (BNC)
Word Clock
Distribution Box
WC IN (BNC)
DME64N/24N
WC IN (BNC)
DME64N/24N
Word Clock Slave
WC IN (BNC)
WC IN (BNC)
DME64N/24N
Word Clock Slave
DME64N/24N
Word Clock Slave
Word Clock Slave
Daisy Chain Connection
Word Clock
Master
WC OUT (BNC)
WC IN
(BNC)
WC OUT
(BNC)
DME64N/24N
Word Clock Slave
WC IN
(BNC)
WC OUT
(BNC)
DME64N/24N
Word Clock Slave
WC IN
(BNC)
DME64N/24N
Word Clock Slave
DME64N/24N Owner’s Manual
33
Connection
REMOTE Connection
The [REMOTE] connector can be connected to remotely-controllable Yamaha AD8HR or AD824 head
amplifiers (preamplifiers), or RS-232C compatible controllers. Up to 8 head AD8HR/AD824 head amplifiers
can be connected. Control can be handled either from the Utility display HA page (described on page 54 of
this manual), or from the DME Designer application.
When connecting to a combination of AD8HR and AD824 head amplifiers, be sure to place the AD8HR
units closest to the DME64N/24N in the chain, otherwise the AD8HR unit(s) may not be properly
recognized by the DME64N/24N.
9-pin D-SUB Cable (Interlink Cross)
REMOTE
HA REMOTE 1
AD8HR
DME64N/24N
COM PC/RS422
AD824
HA REMOTE 2
HA REMOTE 1
HA REMOTE 2
AD8HR
COM RS422
COM PC/RS422
AD824
COM RS422
COM PC/RS422
AD824
Preparation
N OT E
Only control signals are transmitted and received via the REMOTE connection. Audio connections must be made separately.
When connecting an RS-232C compatible controller set the Utility display “Misc” page “Remote” parameter
to “COM (RS232C)” – see page 51 of this manual.
34
DME64N/24N Owner’s Manual
Connection
Analog Audio Connection ([IN] and [OUT] Connectors) (DME24N only)
The DME24N includes [IN] and [OUT] connectors for 8 channels of analog audio input and output. Wire
the supplied Euroblock plugs as shown below. Head amplifier gain and phantom power settings can be made
via the Utility display HA page described on page 54 of this manual, or via the DME Designer application.
Cable Preparation
Prepare cables to be attached to a Euroblock plug as shown below.
Shielded Cable
7mm
30mm
Be sure to use shielded cable.
CAUTION
Do not tin (plate with solder) the exposed sections of the cable.
WARNING
Euroblock Connection
N OT E
A slotted screwdriver with a blade width of about 3 millimeters is recommended.
Preparation
3mm
1. Loosen terminal screws.
Loosen.
Slotted Screwdriver
Terminal Screw
Euroblock Plug
2. Insert cables.
3. Securely tighten terminal screws.
Pull the cables (not too strongly) to confirm that they are securely connected.
4. Plug the Euroblock plug into the panel connector.
+: Hot
-: Cold
G: GND
DME64N/24N Owner’s Manual
35
Connection
Condenser
Microphone
Condenser
Microphone
8
7
6
5
4
3
2
1
8
7
6
5
4
3
2
1
Connection Box
(XLR → Euroblock conversion)
THRU
IN
MIDI
OUT
WORD CLOCK
REMOTE
IN
8
7
6
5
4
3
2
IN
OUT
+V
AC IN
1
75Ω TERMINATED
OUT GND
IN
IN
SLOT
8
7
6
5
8
7
6
5
4
3
2
1
4
3
2
1
OUT
OUT
DME24N
N OT E
Preparation
Analog audio input and output can also be connected via an I/O Card installed in a DME64N/24N I/O card slot.
36
DME64N/24N Owner’s Manual
Connection
I/O Slots
The DME64N has four I/O card slots, and the DME24N has one I/O card slot. The number of audio input
channels available on the DME64N/24N can be increased by plugging the appropriate mini-YGDAI I/O
card(s) into the available card slot(s). Some types of cards also provide control and/or word clock transmission
and reception functionality.
Refer to “I/O Card Installation” on page 22 of this manual for card installation instructions.
For the latest information on what cards can be used with the DME64N/24N, visit the Yamaha Pro Audio
website at: http://www.yamahaproaudio.com/
CobraNet Connection
If an MY16-C CobraNet interface card is installed in a DME64N/24N card slot it becomes possible to
transfer audio, control, and word clock signals via a CobraNet network. MY16-C equipped DME64N/24N
units can be connected to any other CobraNet compatible equipment for broad-ranging audio and word
clock signal networkability. Refer to the MY16-C Owner’s Manual for CobraNet network details.
Example: Connection to CobraNet Devices
Straight Cable
ACU16-C
MY16-C
Audio and
Control Signals
Audio Signal
Preparation
DME64N
Switching Hub
Audio and
Control Signals
Audio Signal
MY16-C
1
EXT.
CLOCK
NETWORK
96kHz
MID
88.2kHz
MASTER
48kHz
2
3
4
2
3
4
5
6
7
8
5
6
7
8
PEAK
IN
SIGNAL
1
44.1kHz
PEAK
SCENE NUMBER
SIGNAL
NETWORK HUB AND BRIDGE
OUT
LINK
LOCK
DME24N
CONDUCT
ERROR
88
NHB32-C
NO T E
Control signals cannot be transferred between devices that do not use the MY16-C card in some cases.
NO T E
CobraNet is an audio networking system developed by Peak Audio (a division of Cirrus Logic, Inc.) that allows real-time
transmission and reception of multiple channels of uncompressed digital audio signals via a Fast Ethernet (100 megabits/sec.)
network. A single network cable can handle a maximum of 64 channels (128 channels bidirectional) of audio data.
The Peak Audio home page can be viewed on the web at: http://www.peakaudio.com/
DME64N/24N Owner’s Manual
37
The Panel Buttons and Displays
Panel Operation and Displays
The Panel Buttons and Displays
By pressing the panel buttons it is possible to select the DME64N/24N Main display, Utility display, and Parameter Edit
displays that allow individual settings to be edited and changed. refer to the pages listed below for more detailed information
about each display.
[HOME] button ➔ Main Display (Page 39)
The Main display can be directly recalled from any display other than the Main display by pressing the
[HOME] button. The Main display shows the current scene information
HOME
[HOME] button ➔ User-defined Parameter Page Selection (Page 42)
Pressing the [HOME] button while the Main display is shown sequentially selects the four user-defined
parameter pages.
HOME
Panel Operation and Displays
Main display
Switches the pages of the user-defined parameter
[MUTE] button ➔ Mute Display (Page 42)
[LEVEL] button ➔ Output Level Display (Page 42)
[SCENE] button ➔ Scene Recall Display (Page 43)/Scene Store Display (Page 43)
These buttons can be pressed from the Main or Utility displays to directly call the related parameter edit
displays.
[MONITOR] button ➔ Monitor Point Selection Display (Page 44)
This function is useful for level monitoring. When the button is pressed the monitor point selection display
will appear, and the spectrum analyzer display will appear when a selection has been made.
[UTILITY] button ➔ Utility Display (Page 47)
The Utility display appears when the [UTILITY] button is pressed for longer than two seconds while the Main
display is showing.
The Utility display includes a number of pages that can be selected in sequence by repeatedly pressing the
[UTILITY] button.
38
DME64N/24N Owner’s Manual
Main Display
Main Display
The Main display will appear in a few seconds after the
power is turned on. The Main display shows information
about the current scene.
NO T E
Nothing will appear on the display if no scene data is stored in
the DME64N/24N scene memory (this is the case when the unit
is initially shipped, for example).
Up to 24 parameters can be accessed from the DME64N/
24N or ICP1 control panel for each scene. Six parameters
are shown on the Main display at a time.
: Mute ON
2
1 Scene Information
The current scene number and name. Scene names can be
entered by using the DME Designer application.
A maximum of 12 one-byte (Roman) characters can be
displayed in a scene name. When “two-byte” characters are
to be used for languages such as Japanese, the total number
of displayable characters is reduced accordingly.
When the power is turned on the last scene selected before
the power was turned off is automatically recalled.
2 User-defined Parameter Names
Displays the user-defined parameters. The parameters are
specified by using the DME Designer application.
A maximum of 24 parameters can be made available for
user control, but only six parameters can be shown in any
one display page. Press the [HOME] button to switch to
other available parameter pages. A maximum of 8 one-byte
(Roman) characters can be displayed in a parameter name.
When “two-byte” characters are to be used for languages
such as Japanese, the total number of displayable characters
is reduced accordingly.
Parameters are selected for editing by using the cursor
buttons – [E] [ ▲ ] [ ▼ ] [F] – to select the parameter,
and then pressing [ENTER].
5 Output Level Indicator
Displays the current output level in 10 increments.
The longer the “bar,” the higher the output level.
6 Panel Lock Icon
This icon appears when the panel lock function is turned
ON.
: Panel Lock ON (Panel controls locked)
Panel Operation and Displays
4
5
6
3
4 Mute Indicator
Shows the current mute ON/OFF status.
: Mute OFF
2
1
3 Page Scroll Bar
The scroll bar provides an indication of which parameter
page is currently being displayed. 4 pages are available, and
the scroll bar moves one position to the right each time the
[HOME] button is pressed and a new page of parameters
is selected, and then back to the leftmost position after the
rightmost position has been reached.
Panel Lock
The panel controls can be “locked” to prevent
accidental mis-operation.
To activate the panel lock function simultaneously press
and hold the [HOME] and [ENTER] buttons for
longer than 2 seconds.
The panel lock icon will appear on the Main display
when the panel is locked.
Panel lock icon
Panel Lock can be disengaged by pressing the
[CANCEL] button for longer than 2 seconds.
NOTE
The panel lock function can be set up to lock just the panel
buttons (“Key Only”), or the panel buttons and GPI control
(“Key+GPI”). You can also select whether or not the panel lock
function is automatically engaged when the unit is initially
turned on. This selection can be made via the Utility display
“Lock” page (refer to the page 50).
DME64N/24N Owner’s Manual
39
Parameter Edit Displays
Parameter Edit Displays
Parameter Edit displays will appear when the [SCENE],
[MUTE], [MONITOR] or other button is pressed to
allow scene changes, level adjustment, and other settings to
be edited as required. Parameter Edit displays are also used
to edit utility parameters.
In most cases the desired parameter edit page can be
accessed by selecting the item you want to edit in the
appropriate display by using the cursor [E], [ ▲ ], [ ▼ ],
and [F] buttons, and then pressing the [ENTER]
button.
Some Parameter Edit displays have just one numeric
parameter, while other may have two or more.
Parameter Edit Display with One Numeric Parameter
1. Numeric values can be changed by rotating the
dial. Dial rotation produces an immediate,
corresponding change in the selected value.
There are basically three types of parameters that can be
accessed via a Parameter Edit display:
• Numeric values
• Lists
• ON/OFF switches
Numeric Parameters
Numeric parameters can be edited in a number of ways,
and depending on the parameter a fader, knob, or
minimum and maximum values may appear to the left of
the numeric value.
2. Press the [ENTER] button to close the
Panel Operation and Displays
A Numeric Value with a fader
1
5
Parameter Edit display after the value(s) have
been edited as required.
Parameter Edit Display with Multiple Numeric
Parameters
2
4
A Numeric Value with a Knob
1
5
1. Use the cursor buttons – [E] [ ▲ ] [ ▼ ] [F] –
to select the value to be edited.
3
4
1
2
3
4
5
40
Name of parameter selected for editing
Fader
Knob
Minimum and maximum values
Current value
DME64N/24N Owner’s Manual
Parameter Edit Displays
2. Rotate the dial to edit the value as required.
List Parameters
List parameters allow you to make one selection from a list
of possibilities.
Rotate the dial to scroll up or down the list. In some cases
the centermost item on the display will be always
highlighted as the list is scrolled, and in others the same
item will remain highlight as the list is scrolled up or down.
List Parameter with Center Item Always Highlighted
3. Repeat step 1 to select the next value to be
edited, use the dial to edit as required, and
repeat until all values have been edited as
required.
4. When all values have been edited, press the
[ENTER] button. A confirmation window will
appear: press [ENTER] one more time to
confirm the edits and close the window.
1. Use the dial to scroll up or down the list.
As you scroll the centermost item on the display will be
highlighted.
2. Press the [ENTER] button to select the
highlighted item and close the window.
ENTER
Panel Operation and Displays
List Parameter with Scrolling Highlight
1. Use the dial to scroll up or down the list.
ENTER
As you scroll the highlighted selection will remain
highlighted, and will scroll up or down with the list.
2. Press the [ENTER] button to highlight the
NO T E
You can close the window without changing any values by
pressing the [CANCEL] button rather than the [ENTER]
button.
centermost item on the display.
NOTE
In some cases a confirmation dialog will appear when the
[ENTER] button is pressed. If this occurs press the [ENTER]
button a second time to continue.
3. Press the [ENTER] button to select the
highlighted item and close the window.
DME64N/24N Owner’s Manual
41
Parameter Edit Displays
ON/OFF Parameters
Mute Switching
Parameters that are either ON or OFF are edited via this
type of display (e.g., Mute Parameter Edit display in “Mute
Switching” on page 42).
Turns the DME64N/24N output mute function ON or
OFF.
1. Rotate the dial clockwise to select ON, or
1. Press the [MUTE] button.
counterclockwise to select OFF.
The Mute Parameter Edit display will appear.
2. Press enter to confirm the selection and close
the window.
Parameter Edit displays will also appear when the
[SCENE], [MUTE], [MONITOR] or other button is
pressed.
These allow scene changes, level adjustment, and other
settings to be edited as required.
2. Select Mute ON or OFF.
The mute function is turned on or off as described in
“ON/OFF Parameters” on page 42.
NOTE
To access this function from the ICP1 control panel, hold the
[F6] button for longer than 2 seconds.
Editing User Defined Parameters
NOTE
PHONES jack output is not muted.
1. If the Main display is not showing, press the
[HOME] button to recall it.
Panel Operation and Displays
2. Press the [HOME] button until the page
containing the parameter to be edited appears.
3. Use the [E] [ ▲ ] [ ▼ ] [F] buttons select the
parameter to be edited.
4. Press the [ENTER] button.
The Parameter Edit display for the selected user-defined
parameter will appear.
NO T E
User-defined parameters can be of all three types: numeric, list,
and ON/OFF.
Output Level Control
Adjust the output level of the DME64N/24N.
NOTE
Output level settings apply individually to each DME64N/24N
unit. There is no overall zone setting.
This function cannot be accessed from the ICP1 control panel.
1. Press the [LEVEL] button.
The “Output Level” Parameter Edit display will appear.
NO T E
When editing from an ICP1 control panel, the [F1] ~ [F6]
buttons are used for parameter selection.
5. Edit the user-defined parameter as required.
Refer to “Parameter Edit Displays” on page 40 for editing
procedures.
NO T E
Any changed user-defined parameter values will be lost if the
power is turned off or if scenes are changed. To preserve the
changed values, store the scene data.
42
DME64N/24N Owner’s Manual
2. Adjust the numeric output level parameter as
required.
The Output Level parameter is adjusted as described in
“Numeric Parameters” on page 40. The graphic fader
provides a visual indication of the current output level
setting.
Parameter Edit Displays
Scene Recall
This procedure recalls a new scene (refer to page 14).
NOTE
If head amplifier parameters are included in the recalled scene
data, the head amplifier settings will be changed accordingly.
NO T E
The same procedure is used for scene recall from an ICP1 control
panel.
Scene Store
1. Press the [SCENE] button.
The Scene Recall display will appear.
Stores the current scene data for later recall.
NOTE
This function can be accessed in the same way from the ICP1.
1. Press the [SCENE] button for longer than 2
seconds.
A confirmation window will appear on the display.
2. Select a new scene.
Scenes are selected as described in the “List Parameters”
section on page 41.
2. Press the [ENTER] button.
This stores the scene data in the current scene memory.
3. Press the [ENTER] button.
A confirmation window will appear.
Panel Operation and Displays
NOTE
Press the [CANCEL] button if you want to abort the scene store
operation.
NOTE
If head amplifier settings are included in the scene the Utility
display HA page settings are also stored. If head amplifier settings
are not included in the scene, the HA page settings are stored as
head amplifier startup settings.
NOTE
4. Press the [ENTER] button again.
The new scene will be selected.
Any parameter values changed by GPI/MIDI controllers will be
lost if the power is turned off or if scenes are changed. To preserve
the changed values, store the scene data.
NO T E
Scenes can also be changed from a computer or GPI/MIDI
controller connected to the device.
The DME Designer application is used to make scene changes
from a computer. If a GPI/MIDI controller is to be used for
changes it must be initially set up for scene change control by
using the DME Designer.
DME64N/24N Owner’s Manual
43
Parameter Edit Displays
Monitoring
The monitor functions allow you to monitor the audio
signal at the inputs or outputs of I/O slots, points between
components, and other critical monitoring points.
NO T E
User-defined monitoring functions, such as monitoring at points
between components, must specified via the DME Designer
application.
NO T E
These functions cannot be accessed from the ICP1.
1. Press the [MONITOR] button.
The slots available for monitoring will be shown in the
parameter list.
2. Select the desired monitor source from the list.
Panel Operation and Displays
List selections are made as described in the “List
Parameters” section on page 41.
When a selection is made the Monitoring Point display
will appear.
3. Select the desired monitor point from the list.
The audio signal from the selected monitoring point will
be output via the PHONES jack.
NO T E
Press the [CANCEL] button to move back to the previous edit
display.
44
DME64N/24N Owner’s Manual
Probe Monitor Functions
The Probe Monitor function allows monitoring points to
be selected from the DME Designer application. Only slot
inputs and outputs and monitoring points previously
specified via the DME Designer application can be selected
from the DME64N/24N control panel, but the “Probe
Monitoring” function allows monitoring points to be
freely selected. Refer to the DME Designer Manual for
details.
NOTE
“Probe” will appear on the DME64N/24N display while the
Probe Monitor function is active.
Spectrum Display
Spectrum Display
The monitor functions also provide spectrum analyzer type
level display of the signal at the selected monitor point.
NO T E
Spectrum display is not available on the ICP1 control panel.
Procedure
1. Select the monitor point for which you want to
see a spectrum display from the list.
4 L/R Select
Indicates when the spectrum display is for the left or right
channel. The same spectrum display will be shown for the
L and R channels of all monitor points other than userdefined points specified via the DME Designer
application.
To switch between the L and R displays move the cursor to
the CHANNEL L/R setting and press the [ENTER] key
to alternately select L or R.
NOTE
The fall rate of the meters can be set up via the Utility display
“Disp” page.
2. Press the [ENTER] button.
A spectrum display of the audio signal at the selected
monitor point will appear.
1
4
3
2
Panel Operation and Displays
1 Frequency
These are the separate frequency bands displayed.
2 Band Output Level
Signal level is displayed independently in 31 separate
frequency bands. Output level is displayed in 12 steps.
3 Peak Hold
When the peak hold function is ON, peak levels since the
current monitor point was selected are held indefinitely.
Peak levels are cleared after one second when peak hold is
OFF.
To turn the peak hold function ON or OFF, move the
cursor to the PEAK HOLD ON/OFF setting and press the
[ENTER] key to alternately turn it ON or OFF.
DME64N/24N Owner’s Manual
45
Level Meter Display
4 Peak Hold
When the peak hold function is set to ON, peak levels are
held indefinitely.
Peak levels are cleared after one second when peak hold is
set to OFF.
Level Meter Display
Individually displays the input/output level for each
channel.
NO T E
Level display is not available on the ICP1 control panel.
1. Make sure that the Main display is showing.
If the Main display is not showing, press the [CANCEL]
to return.
2. Press the [UTILITY] button.
The level meter display will appear.
1
4
3
2
1 Level Display Slot
Select from [SLOT1] ~ [SLOT4], [A/D D/A],
[CASCADE IN] or [CASCADE OUT].
Panel Operation and Displays
NO T E
[SLOT2] ~ [SLOT4] and [CASCADE IN], [CASCADE OUT]
are only available on the DME64N, while [A/D D/A] is only
available on the DME24N.
2 Channel Number
A maximum of 32 [CASCADE IN]/[CASCADE OUT]
channels can be displayed, while for other channels a
maximum of 16 can be displayed.
3 Input/Output Level Display
Shows the levels at the individual inputs and outputs.
46
DME64N/24N Owner’s Manual
To turn the peak hold function ON or OFF, move the
cursor to the PEAK HOLD ON/OFF setting and press the
[ENTER] key to alternately turn it ON or OFF.
Utility Displays
Utility Displays
Most basic DME64N/24N functions can be accessed via the Utility Display.
Items accessible via the Utility display
Item
Name
Version
Date
Battery
Net
Zone
IP Adr.
Link Mode
MAC Adr.
Disp
LCD Contrast
LCD Backlight
Meter Fall Time
Lock
Utility
Panel Lock Boot
Panel Lock Target
User Defined Lock
Misc
Scene Store
Remote
WCLK
Fs
Int
WCIN
Cascade
SLOT1-4
Slot
Card name
(no title)
Format
MIDI
Host
DAW
CH
Program Change
Control Change
Param Change
GPI
Reset
Max
Min
(no title)
HA
HA
WCLK
(no title)
Gain
+48V
(no title)
HPF
Frq
CASCAD
Head Margin
Unit No.
Mixer I/O
Description
Manual Page
Current status and settings for the devices basic parameters.
User ID display.
The device’s current version number.
Current status and setup for the internal calendar/clock.
Shows the status of the internal battery.
Current status and settings for the Ethernet network.
Displays current status and determines whether the device is zone master or not.
Current status and setup for the device’s IP address.
Current status and setup for the [NETWORK] connector.
Displays the device’s MAC address.
Current status and setup for the display mode, etc.
Current status and setup for display panel contrast.
Current status and setup for the display panel backlight.
Current status and setup for meter fall time.
Current status and setup for panel lock and related functions.
Current status and setup for the Utility display settings.
Current status and setup for the DME64N/24N’s power-on panel lock status.
Current status and setup for the panel lock target.
Panel lock and setup for each page of user-defined parameters.
Current status and setup for settings not included in other pages.
Current status and setup for scene store accessibility.
Current status and setup for the [REMOTE] connector.
Current status and selection of the DME64N/24N word clock.
Displays the word clock frequency.
Current status of the internal word clock.
Current status of the word clock received at the [WORD CLOCK IN] connector.
Current status of the word clock received via the [CASCADE IN] and [CASCADE OUT]
connectors.
Current status of the word clock received via cards plugged in to the I/O card slots.
Displays info about an I/O card installed in a DME64N/24N I/O slot.
Displays the name of the installed card.
Resets the installed card.
Displays the audio format – 88.2 or 96 kHz.
Current status and setup for MIDI functions.
Current status and setup of the MIDI port.
Current status and setup for connected MIDI devices.
Current status and setup for the MIDI transmit and receive channels.
Current status and setup for program change transmission/reception, omni on, and echo
on/off.
Current status and setup for control change transmission/reception, omni on, and echo
on/off.
Current status and setup for parameter change transmission/reception, omni on, and echo
on/off.
GPI connector calibration and status display.
Resets the GPI calibration.
Sets the maximum calibration value.
Sets the minimum calibration value.
Current calibration status.
Current status and setup for the internal and connected external head amplifiers.
Current status and setup for head amplifier type.
Current status and setup for the word clock used by the head amplifier(s).
Displays the audio format 88.2/96 kHz.
Current status and setup for individual head amplifier channel gain.
Current status and setup for individual head amplifier channel phantom power supply (+48V
ON/OFF).
Displays current status of the master phantom power switch.
Current status and setup for individual head amplifier channel high-pass filter on/off.
Current status and setup for individual head amplifier channel high-pass filter frequency.
Current status and setup for the [CASCADE] connectors.
Status and setup for the head margin of the audio signal handled via the [CASCADE]
connectors.
Specifies how many devices the unit is from the beginning of the cascade chain.
Status and setup for the channels to be used for audio signals cascaded to a mixer.
Page 48
Page 48
Page 49
Page 50
Page 51
Page 51
Panel Operation and Displays
Page
Info
Page 52
Page 52
Page 53
Page 54
Page 55
DME64N/24N Owner’s Manual
47
Utility Displays
Utility Display Operation
The general procedure for operating the Utility displays is
outlined below.
1. Press the [UTILITY] button for longer than
2 seconds from the Main display to go to the
Utility display.
2. Press the [UTILITY] button as many times as
3 Date
Shows the currently set date and time. The internal clock
and calendar can be set here.
Edit using the “Numeric Parameters” editing procedure
described on page 40.
NOTE
“Zone slave” cannot be used to set this parameter.
Date/Time Parameter Edit Dialog
necessary until the desired parameter page
appears.
3. Use the cursor buttons – [E] [ ▲ ] [ ▼ ] [F] –
to select the parameter you want to edit.
NO T E
On the ICP1 the function buttons are used in place of the cursor
buttons as follows:
[F1] button: Left
[F2] button: Up
[F3] button: Right
[F5] button: Down
4. Press the [ENTER] button.
This either confirms a selection or edit, or calls the
appropriate parameter edit page.
Year • Month • Day
Hour : Minute : Second
4 Battery
Shows the status of the internal battery. “Low Battery” will
appear when the battery needs to be replaced, and “No
Battery” will appear when no battery is present in the
device.
Panel Operation and Displays
Network Settings (Net) Page
Info Page
Shows the Ethernet network address and other parameters.
1
2
3
4
NO T E
The date and time (3) and the internal battery status (4) are
not shown on the ICP1 control panel display.
1 Name (User ID)
Shows the user ID. The user ID can be changed via the
DME Designer application running on a computer
connected to the unit.
NO T E
The user ID can not be changed from the DME64N/24N
controls.
1
2
3
4
1 Zone
Indicates whether or not the device is functioning as the
zone master: “Master” or “Slave.”
Master: the device is the zone master.
Slave: the device is a zone slave.
Edit using the “List Parameters” editing procedure
described on page 41.
NOTE
Zone status of ICP1 is fixed to “Slave.” This cannot be changed.
NOTE
2 Program Version
This is the current firmware version number.
48
DME64N/24N Owner’s Manual
Make sure that one zone master is assigned for each zone.
If no zone master is assigned, no scene information will appear on
the display and scene-related control will not be possible. Mute
operations will also not be possible.
Utility Displays
2 IP Adr.
This is the device’s IP address.
Edit using the “Numeric Parameters” editing procedure
described on page 40.
Display Setup (Disp) Page
Provides access to a number of display parameters.
NOTE
The meter fall time (3) is not shown on the ICP1 control panel
display.
1
2
Network Address
Host Address
3
NO T E
3 Link Mode
Shows the status of the [NETWORK] connector. The
[NETWORK] connector can be set to operate in “10BaseT” or “100Base-TX” mode.
10Base-T: The [NETWORK] connector is compatible
with 10Base-T operation.
100Base-TX: The [NETWORK] connector is
compatible with 100Base-TX operation.
Edit using the “List Parameters” editing procedure
described on page 41.
4 MAC Adr.
This is the device’s MAC (Media Access Control) address.
NO T E
The MAC address is also known as the Ethernet address, and is
an independent address assigned to all Ethernet devices. No two
devices anywhere in the world can have the same address.
1 LCD Contrast
The current LCD contrast setting. This parameter can be
adjusted from 0% through 100%.
Edit using the “Numeric Parameters” editing procedure
described on page 40.
2 LCD Backlight
Specifies LCD backlight operation. Two settings are
available: “ON,” and “OFF.”
ON: The display is continuously lit.
OFF: The display lights when a control is operated, and
will go out 10 seconds after panel operation ceases.
Edit using the “List Parameters” editing procedure
described on page 41.
Panel Operation and Displays
The network addresses of devices in the same zone must be the
same.
The host address of the zone master is fixed at “2.”
3 Meter Fall Time
Determines the fall time of the level meters – “Fast” or
“Slow.”
Fast: The meters rapidly follow changes in the signal
level.
Slow: The meters fall slower than the actual changes in
the signal level, allowing easier reading in some cases.
Edit using the “List Parameters” editing procedure
described on page 41.
DME64N/24N Owner’s Manual
49
Utility Displays
Security Setup (Lock) Page
Panel lock and related settings.
1
2
3
4
1 Utility
The lock status for the Utility display settings. This
parameter can be set to “Unlock” or “Lock.”
Unlock: The Utility display can be accessed without a
password.
Lock: A password must be entered to access the Utility
display.
2 Panel Lock Boot
Determines whether or not panel lock will be on when
power to the device is turned on. This parameter can be set
to “Unlock” or “Lock.”
Unlock: Panel lock is OFF when power to the device is
turned on.
Lock: Panel lock is ON when power to the device is
turned on.
3 Panel Lock Target
Determines the controls (control functions) to be affected
by panel lock. The available settings are “Key Only” and
“Key+GPI.”
Key Only: Panel lock only affects the panel buttons.
Key+GPI: Panel lock applies to the panel buttons as well
as GPI control input.
NOTE
See page 39 for details on how to use the Panel lock feature.
When “Lock” is selected a password entry window will
appear when the [UTILITY] button is pressed to access
the utility pages.
4 User Defined Lock
Sets the lock status individually for each of the four userdefined parameter pages.
ON: The corresponding user-defined parameters will not
appear on the display.
Panel Operation and Displays
OFF: The corresponding user-defined parameters will
appear on the display.
Use the [E] and [F] buttons to position the cursor,
and the dial to enter the desired character at the cursor
location. When all of the password’s characters have been
entered as required press the [ENTER] button.
To change the settings use the [E] and [F] buttons to
move the cursor to the setting for the desired page, the
press the [ENTER] button to alternately turn the setting
“ON” and “OFF.”
NOTE
The password will also be required when switching from
the “Unlock” mode to the “Lock” mode.
NO T E
Password security and management is very important!
If you forget your password the unit cannot be operated!
If you forget your password contact the system administrator.
If the password become unrecoverable for some reason and you
need to unlock the system, please contact your Yamaha
representative.
50
DME64N/24N Owner’s Manual
The user-defined parameters are accessed as described in the
“Parameter Edit Display” section on page 40.
Utility Displays
Miscellaneous Setup (Misc) Page
Word Clock Setup (WCLK) Page
This page includes parameters not available in any other
page.
Shows the status of incoming word clock signals, and
allows setup of the DME64N/24N master word clock.
NO T E
NOTE
The Remote setting (2) will not appear on the ICP1 control
panel display.
This page will not be displayed on the ICP1.
2
1 Scene Store
Determines whether or not scene store operations are
allowed. This parameter can be set to “Enable” or
“Disable.”
Enable: Scene store operations are allowed.
Disable: Scene store operations are prohibited.
Edit using the “List Parameters” editing procedure
described on page 41.
NO T E
See page 43 for scene store procedure.
NO T E
This setting applies to individual devices only. Even if one
DME64N/24N unit is set to “Disable,” scene store operations
will be possible via another DME64N/24N in the same zone that
is set to “Enable.”
2 Remote
Determines the [REMOTE] connector communication
mode. Available settings are “HA Control (RS422)” and
“COM (RS232C).”
Edit using the “List Parameters” editing procedure
described on page 41.
This parameter must be set to “HA Control (RS422)”
when connecting to an AD8HR or AD824 remote head
amplifier.
Do not change the “HA Control (RS422)” setting while
connected a head amplifier to prevent possible damage to
the device(s).
When controlling the DME64N/24N from an RS232C
type controller set this parameter to “COM (RS232C).”
1
2
3
4
5
Master Clock Selection Procedure
1. Use the cursor [E], [ ▲ ], [ ▼ ], [F] buttons
to select one of the square blocks representing
the available master clock sources.
2. Press the [ENTER] button to select the master
clock.
1 Fs
The current sampling frequency of the master word clock.
The value shown here is determined by the system’s master
word clock signal. To select the word clock to be used as
the master, move the cursor to the appropriate word clock
indication in this display – the [WORD CLOCK IN]
clock, the cascade clock, or a slot clock, for example – and
press the [ENTER] button.
Panel Operation and Displays
1
2 Int
Sets the frequency of the internal word clock – 44.1 kHz,
48 kHz, 88.2 kHz, or 96 kHz.
3 WCIN
Shows the status of the word clock signal at the [WORD
CLOCK IN] connector.
4 Cascade
Shows the status of the word clock signal at the
[CASCADE IN] and [CASCADE OUT] connectors.
5 SLOT1~4
Shows the status of the word clock signal input via I/O
cards installed in the I/O slots.
DME64N/24N Owner’s Manual
51
Utility Displays
The Status Icons
A word clock signal is present, and this signal can be
selected as the DME64N/24N word clock.
MIDI Setup (MIDI) Page
3
No word clock signal (cannot be selected as the master
clock).
A word clock signal is present, but is not in sync with
the master word clock.
Currently selected as the DME64N/24N word clock.
Currently selected as the DME64N/24N word clock, but
the clock signal is not useable.
Inactive slot channel, or no I/O card is present in the
slot.
1
2
4
5
6
NOTE
This page will not appear on the ICP1 display.
1 Host
Determines the active MIDI port: MIDI, USB-1, USB-2,
SLOT-1, SLOT-2, SLOT-3, or SLOT-4.
Slot Information (Slot) Page
Displays the name of the card installed in an I/O card slot.
Some cards can also be reset via this page.
MIDI: The MIDI connector is the currently active MIDI
port.
USB-1, USB-2: The corresponding USB port is selected
for MIDI input.
SLOT-1, SLOT-2, SLOT-3, SLOT-4: A card installed
in the corresponding I/O slot is currently selected for
MIDI input.
2
1
3
Panel Operation and Displays
NO T E
This page will not appear on the ICP1 display.
1 Card Name
The name of the installed card appears here.
2 Reset
Resets the installed card.
3 Format
Displays the 88.2/96 kHz audio signal transfer mode. The
input setting is on the left and the output setting is on the
right.
No Display (Default): 44.1/48 kHz audio signal
transfer.
SP (Double Speed): An 88.2/96 kHz capable card is
installed, allowing direct transfer at 88.2 or 96 kHz.
CH (Double Channel): A 44.1/48 kHz card is
installed, and 88.2 or 96 kHz audio is transferred by using
two 44.1/48 kHz channels to transfer each channel of
88.2/96 kHz audio. The number of audio channels that
can be handled in this mode is half the number of
channels normally handled by the card.
52
DME64N/24N Owner’s Manual
Edit using the “List Parameters” editing procedure
described on page 41.
NOTE
When the DME64N/24N is functioning as the zone master and
is connected to a computer running the DME Designer
application via USB, the MIDI port being used by the DME
Designer will not be available.
2 DAW
Specifies the type of MIDI device (DAW control surface,
etc.) to be connected. The choices are OFF, TYPE1, and
TYPE2.
OFF: Use this setting when any MIDI device other than a
general-purpose ProTools controller (HUI protocol) or
general-purpose Logic or Cubase controller (Mackie
control protocol) is to be connected.
TYPE1: Use this setting when a general-purpose
ProTools controller (HUI protocol) is to be connected.
TYPE2: Use this setting when a general-purpose Logic or
Cubase controller (Mackie control protocol) is to be
connected.
Edit using the “List Parameters” editing procedure
described on page 41.
Refer to the DAW controller owner’s manual as well as the
DME Designer manual for setup details.
Utility Displays
NO T E
“DAW” stands for “Digital Audio Workstation.” ProTools, Logic,
and Cubase are DAW applications, and this parameter provides
direct compatibility with a number of physical controls surfaces
that are available for use with these DAW software packages.
GPI Setup (GPI) Page
Input calibration parameters for the [GPI] connector.
NOTE
This page will not appear on the ICP1 display.
The following parameters are available when the DAW
parameter is set to OFF.
4 Program Change
Turns transmission and reception, the omni mode, and
echo ON or OFF for MIDI program change messages.
Move the cursor to the required parameter, then press the
[ENTER] button to alternately turn ON and OFF.
5 Control Change
Turns transmission and reception, the omni mode, and
echo ON or OFF for MIDI control change messages.
Move the cursor to the required parameter, then press the
[ENTER] button to alternately turn ON and OFF.
6 Parameter Change
Turns transmission and reception, and echo ON or OFF
for MIDI parameter change messages.
Move the cursor to the required parameter, then press the
[ENTER] button to alternately turn ON and OFF.
1
2
4
3
1 Reset
Resets GPI calibration.
To reset the calibration, use the [E] [ ▲ ] [ ▼ ] [F]
buttons to select ALL to reset all inputs, or select an
individual input from 1 to 16 to be reset, then press the
[ENTER] button.
2 MAX
Sets the maximum calibration value.
To set the MAX value, use the [E] [ ▲ ] [ ▼ ] [F]
buttons to select ALL to set all inputs, or select an
individual input from 1 to 16 to be set, then press the
[ENTER] button to set the MAX value to the current
input voltage.
Panel Operation and Displays
3 CH
Specifies the device’s MIDI transmit and receive channel:
1 ~ 16.
Edit using the “List Parameters” editing procedure
described on page 41.
3 MIN
Sets the minimum calibration value.
To set the MIN value, use the [E] [ ▲ ] [ ▼ ] [F]
buttons to select ALL to set all inputs, or select an
individual input from 1 to 16 to be set, then press the
[ENTER] button to set the MIN value to the current
input voltage.
4 Calibration Info
Shows the calibration settings as well as the current input
voltage.
DME64N/24N Owner’s Manual
53
Utility Displays
Head Amplifier Setup (HA) Page
Provides access to the head amplifier settings. Refer to
“REMOTE Connection” on page 34 for head amplifier
control signal connection.
NO T E
Available settings of the AD8HR are “D OUT A,”
“WCLK IN,” “INT44.1K,” “INT48K,” “INT88.2K,” and
“INT96K.”
This page will not appear on the ICP1 display.
D OUT A: Sets the word clock signal at the digital input
as the master clock of the AD8HR.
NO T E
WCLK IN: Sets the word clock signal at BNC connector
as the master clock of the AD8HR.
Some scenes include head amplifier settings. In such cases, the
HA page settings will be saved along with the scene when it is
stored.
INT44.1K: Sets the 44.1 kHz internal word clock as the
master clock of the AD8HR.
INT48K: Sets the 48 kHz internal word clock as the
master clock of the AD8HR.
Internal Head Amplifier (DME24N only)
INT88.2K: Sets the 88.2 kHz internal word clock as the
master clock of the AD8HR.
1
INT96K: Sets the 96 kHz internal word clock as the
master clock of the AD8HR.
4
5
Available settings of the AD824 are “SLOT,” “BNC,”
“INT44.1K,” and “INT48K.”
SLOT A: Sets the word clock signal input via I/O cards
installed in the I/O slots as the master clock of the
AD824.
AD8HR
2
1
Panel Operation and Displays
6
8
4
7
3
BNC: Sets the word clock signal at the BNC connector as
the master clock of the AD824.
5
INT44.1K: Sets the 44.1 kHz internal word clock as the
master clock of the AD824.
INT48K: Sets the 48 kHz internal word clock as the
master clock of the AD824.
AD824
1
2
4
5
1 HA
Specifies the type of head amplifier to be set up. The
available options are AD8HR, AD824, and Built-in HA
(DME24N only). When the AD8HR and AD824 are
selected, a number indicating the connection order will
also appear.
Edit using the “List Parameters” editing procedure
described on page 41.
54
2 WCLK (AD8HR/AD824 only)
Specifies the word clock signal to be used by the head
amplifier(s).
DME64N/24N Owner’s Manual
3 Format (AD8HR only)
Displays the 88.2/96 kHz audio signal transfer mode. The
input setting is on the left and the output setting is on the
right.
No Display (default): 44.1/48 kHz audio signal
transfer.
SP (Double Speed): Allows direct transfer at 88.2 or
96 kHz.
CH (Double Channel): 88.2 or 96 kHz audio is
transferred by using two 44.1/48 kHz channels to transfer
each audio channel of 88.2 and 96 kHz respectively. The
number of audio channels that can be handled in this
mode is half the number of channels normally handled by
the AD8HR.
Utility Displays
4 Gain
Individually sets the gain of each head amplifier channel.
Edit using the “Numeric Parameters” editing procedure
described on page 40.
NO T E
The gain of the DME24N internal head amplifiers can be
adjusted from +10 dB to –60 dB in 1-dB increments. The
internal circuitry switches at about the –45-dB point, and the
signal is automatically muted at that point to prevent noise.
The AD8HR gain can be adjusted from +10 dB to –62 dB in
1-dB steps, and the AD824 gain can be adjusted from +10 dB to
–62 dB in 6-dB steps.
5 +48V
Individually turns phantom power ON or OFF for each
head amplifier channel.
Use the [E] and [F] buttons to position the cursor at
the desired channel, then press the [ENTER] button to
alternately turn phantom power for that channel ON and
OFF.
Cascade Setup (CASCAD) Page
Determines the operation of the [CASCADE] connectors.
Refer to “CASCADE Connection” on page 32 for
connection details.
NOTE
This page only appears on the DME64N.
1
2
3
1 Head Margin
Shows the status and sets the head margin of the audio
signal handled via the [CASCADE] connectors. The
options are “0dB” and “-18dB.”
0dB: The head margin is 0 dB.
-18dB: The head margin is -18 dB.
NOTE
The Head Margin setting only applies when connected to a
mixer. When not connected to a mixer the head margin is
automatically set to 0 dB.
2 Unit No
This parameter specifies how many devices the unit is from
the beginning of the cascade chain.
6 Phantom Master Switch (AD8HR only)
Displays overall phantom power ON or OFF.
OUT
IN
7 High-pass Filter (HPF) (AD8HR only)
Individually turns the high-pass filter for each AD8HR
head amplifier channel ON or OFF. This parameter is only
available for the AD8HR head amplifier. Use the [E] and
[F] buttons to select a channel, then press the [ENTER]
key to turn the HPF for that channel ON or OFF.
8 High-pass Filter Frequency (Frq) (AD8HR
only)
Individually sets the high-pass filter frequency for each
AD8HR head amplifier channel. This parameter is only
available for the AD8HR head amplifier.
Edit using the “Numeric Parameters” editing procedure
described on page 40.
Panel Operation and Displays
CAUTION
• Always turn the phantom power off when it is not
needed.
• Phantom power should only be used with phantompowered condenser microphones. Turning phantom
power ON when other types of equipment are
connected can result in damage. Balanced dynamic
microphones, however, will not be affected by phantom
power.
• To prevent speaker and possible hearing damage, be sure
to turn power amplifiers OFF when turning phantom
power ON or OFF. It is also a good idea to turn the
output level all the way down (page 42).
PM5D
OUT
DME64N
IN
OUT
DME64N
Unit No = 01
Unit No = 02
IN
DME64N
Unit No = 03
3 Mixer I/O
Status and setup for the channels to be used for audio
signals cascaded to a mixer.
Edit by moving the cursor to a channel number and
pressing [ENTER] to set as required.
■: Channel audio will be transmitted to and received
from mixer.
: Channel audio will be transferred between DME64N/
24N units.
NOTE
Make sure that the Mixer I/O setting is the same for all cascaded
DME64N/24N units.
DME64N/24N Owner’s Manual
55
Options
Appendix
Options
The ICP1, CP4SW, CP1SF, and CP4SF controllers are optionally available for remote external control of the DME64N/
24N. The ICP1 connects via Ethernet, while the CP4SW, CP1SF, and CP4SF connect via the GPI interface.
ICP1
This controller connects to the DME64N/24N via Ethernet. Like the DME64N/24N, each ICP1 unit has it’s
own IP address. With a display that replicates the display on the DME64N/24N, the ICP1 allows
comprehensive, familiar control from remote locations.
ICP1 Controls
1
2
3
7
8
!
@
4
5
6
9
)
1 [F1] Button
Appendix
When the Main display is showing this button calls the Parameter Edit display for the user-defined parameter
in the upper left corner of the display.
When the Utility display is showing it has the same function as the [E] cursor button on the DME64N/
24N.
2 [F2] Button
When the Main display is showing this button calls the Parameter Edit display for the middle user-defined
parameter in the upper part of the display.
When the Utility display is showing it has the same function as the [ ▲ ] cursor button on the DME64N/24N.
3 [F3] Button
When the Main display is showing this button calls the Parameter Edit display for the user-defined parameter
in the upper right corner of the display.
When the Utility display is showing it has the same function as the [F] cursor button on the DME64N/
24N.
4 [F4/UTILITY] Button
When the Main display is showing this button calls the Parameter Edit display for the user-defined parameter
in the lower left corner of the display. If this button is pressed and held for longer than 2 seconds when the
Main display is showing the Utility display will appear. Pressing the [F4] button while the Utility display is
showing sequentially steps through the various Utility pages.
56
DME64N/24N Owner’s Manual
Options
5 [F5] Button
When the Main display is showing this button calls the Parameter Edit display for the middle user-defined
parameter in the lower part of the display.
When the Utility display is showing it has the same function as the [ ▼ ] cursor button on the DME64N/24N.
6 [F6/MUTE] Button
When the Main display is showing this button calls the Parameter Edit display for the user-defined parameter
in the lower right corner of the display.
If this button is pressed and held for more that 2 seconds the Mute display will appear.
7 [HOME] Button
Directly recalls the home (main) display. If pressed while the main display is showing the [HOME] button
steps through the user-defined parameter display pages (page 42).
8 [SCENE] Button
Calls the scene recall display (page 43). Calls the scene store confirmation display if pressed and held from
longer than 2 seconds (page 43). The indicator will light green while the scene recall/store display is showing.
9 [CANCEL] Button
Closes the window on the display.
) [ENTER] Button
Confirms and enters a value or setting.
! Display
Displays scene information and device parameters.
@ Dial
Adjusts the value of selected parameters. The ICP1 dial functions in the same way as the DME64N/24N dial.
ICP1 Installation
Please have the ICP1 installed by a Yamaha-qualified contractor. Consult your Yamaha representative.
Appendix
CAUTION
1. Connect the control panel unit and the ICP1 adaptor box.
Use an Ethernet “straight” cable.
WARNING
CAUTION
• Do not use a “cross” cable to connect the control panel unit and adaptor box. Also do not use joint connectors,
cross cable converters, or other extension adaptors.
• Connect ct the control panel unit and adaptor box directly, not via a hub.
• For maximum safety be sure to securely connect the ICP1 earth screw to an earth connection.
Control panel unit
Earth screw
DME64N/24N Owner’s Manual
57
Options
2. Connect the adaptor box to a network hub or the DME64N/24N.
Use a “straight” cable for connection to a hub, or a “cross” cable for direct connection to the DME64N/24N.
N OT E
• Use a 100Base-TX/10Base-T switching hub.
• When using category 5 UTP (Unshielded Twisted Pair) cable, the total length of the cables connecting the control panel unit
to the hub or DME64N/24N can be up to 100 meters. Due to differences in cable and switching hub performance, however,
proper operation at the maximum length cannot be guaranteed in some cases. The maximum usable cable length will also be
reduced if joint connectors, cross cable converters, or other extension adaptors are used.
• Use STP (Shielded Twisted Pair) cable to prevent electromagnetic interference.
F1
F2
1
F3
HOME
F4/UTILI
TY
SCENE
F5
F6
CANCEL
ENTER
INTE
LLIGE
CON
TROL
NT
PANE
L
ICP1
Control panel unit
DC IN
2 To network hub or
DME64N/24N.
ICP1 ADAPT
OR BOX
ICP1
Cord hook
DC IN
MADE IN
JAPAN
ICP1 adaptor box
To AC power outlet
3
AC adaptor (PA-300)
4
3. Connect the PA-300 AC adaptor to the adaptor box.
4. Plug the AC adaptor into an appropriate AC mains outlet.
Appendix
Frame Plate and Control Panel Installation
1.
Screw the frame plate to the terminal box.
NO T E
• Terminal box not included. Use a standard (US-type) wall box: 3-gang with a depth of 44 millimeters or more.
• The screw heads should extend from the frame plate by no more than 3 millimeters.
2.
Screw the control panel to the frame plate.
NO T E
Tighten the screws used to attach the control panel to the frame plate with a torque of less than 1.5 Nm.
1
2
F1
F2
F3
HOME
F4/UTILI
TY
SCENE
F5
F6
CANCEL
ENTER
INTE
LLIGE
CON
TROL
NT
PANE
L
ICP1
Control panel unit
58
DME64N/24N Owner’s Manual
Frame plate for ICP1
Options
CP4SW, CP4SF, and CP1SF
These controllers connect to the DME64N/24N via its GPI interface. These controllers only control the
DME64N/24N unit to which they are directly connected.
The CP4SW is a four-switch unit with four indicator LEDs, while the CP1SF and CP4SF have one and four
faders, switches, and LEDs, respectively. The parameters to be controlled by the switches and faders on these
controllers can be specified via the DME Designer.
Fader
CP4SW
CP4SF
CP1SF
LED
10
10
10
10
10
LED
LED
LED
0
0
CONTROL PANEL
CP4SW
Switch
0
LED
0
0
CONTROL PANEL
CONTROL PANEL
CP4SF
CP1SF
Switch
Switch
Fader
Installation
Please have the CP4SW, CP1SF, and/or CP4SF installed by a Yamaha-qualified contractor. Consult your
Yamaha representative.
Single conductor. Twisted pair.
7mm
Appendix
Cable
Cable lengths up to 100 meters can be used to connect to the DME64N/24N if CPEV cable with a conductor
diameter of greater than 0.65 millimeters is used.
Bare cable ends to be connected to the Euroblock as shown in the diagram.
Shielded cable.
7mm
Be sure to use shielded cable.
CAUTION
Do not tin (plate with solder) the exposed sections of the cable.
WARNING
N OT E
Refer to “Euroblock Connection” on page 35 for instructions on connecting cables to the Euroblock connectors.
DME64N/24N Owner’s Manual
59
Options
Control Panel Installation
1. Screw the frame plate to the terminal box.
N OT E
• Terminal box not included. Use a standard (US-type) wall box: 3-gang for CP4SF and 1-gang for CP4SW and CP1SF with
depth 44 millimeters or more.
• The screw heads should extend from the frame plate by no more than 3 millimeters.
2. Screw the control panel to the frame plate.
N OT E
Tighten the screws used to attach the control panel to the frame plate with a torque of less than 1.5 Nm.
CP4SW
CP1SF
2
2
1
Control panel unit
Euroblock connected
Control panel unit
Control panel unit
2
1
Euroblock connected
Appendix
Frame plate for control
panel mounting
60
DME64N/24N Owner’s Manual
Euroblock connected
Frame plate for control
panel mounting
Frame plate for control
panel mounting
CP4SF
1
Error Messages
Error Messages
Message
Meaning
Action
Error messages
Cannot Select
No selectable items are available in the scene or
monitoring point list display.
Make the appropriate settings via the DME Designer
application.
Flash Rom Full
The flash ROM is full.
Reduce the number of stored scenes.
Invalid Password
An invalid password has been entered.
Enter the correct password. If you have lost or forgotten
your password, contact your Yamaha service center or
representative.
Low Battery
The backup battery voltage is low.
Stop using the device immediately and contact your
Yamaha service center or representative.
MIDI Port In Use
The MIDI host setting is set to the same setting as the
DME Designer application.
Set the Utility MIDI page “Host” parameter to a different
port.
No Battery
The battery is completely depleted.
Stop using the device immediately and contact your
Yamaha service center or representative.
Try again.
Param Access Err
Current setting cannot be displayed.
Param Set Err
Current setting cannot be changed.
Try again.
Saving Failed
A save operation has failed.
Stop using the device immediately and contact your
Yamaha service center or representative.
Slots Overloaded
The current being used by all cards installed in I/O slots
exceeds the rated limit.
Re-install the cards so that the current limit is not
exceeded.
Store Disable
The scene store parameter is set to “Disable.”
Set the scene store parameter to “Enable” via the Utility
display “Lock” page.
CAS. In Sync Err
The DME64N/24N clock is not in sync with the clock
signal being received at the [CASCADE IN] connector.
Set the device connected to the [CASCADE IN]
connector and the DME64N/24N to use the same word
clock.
CAS. Out Sync Err
The DME64N/24N clock is not in sync with the clock
signal being received at the [CASCADE OUT] connector.
Set the device connected to the [CASCADE OUT]
connector and the DME64N/24N to use the same word
clock.
Connecting
Connecting to the network.
None required.
Download Success
The DME64N/24N program has been successfully
updated.
None required.
Downloading
DME64N/24N program update in progress.
None required.
Duplicate IP Adr.
Duplicate IP addresses.
Change the IP addresses so that there are no duplicates.
File Operating
A file operation in which the computer is manipulating
scene data (including configuration and component
data) is in progress.
None required.
Illegal MAC Adr.
An illegal MAC address has been encountered.
This could be due do a hardware malfunction. Refer this
problem to a Yamaha service center or representative.
Invalid IP Adr.
The network ID address is not appropriate.
Set an appropriate network ID address.
Network Busy
There is too much network traffic. Communication is not
possible.
Check the devices connected to the network. If there are
too many devices connected, reduce the number of
devices.
Network Error
One of the following errors has occurred on the network:
• A cable has been unplugged.
• The power to a hub or router has been shut off.
• A cable is in an inappropriate state (e.g. a heavy object
has been placed on the cable, etc.). Static electricity
can also cause errors.
Locate and eliminate the cause of the error.
Network Setup
Preparing network connection.
None required.
No Current Scene
There is no data in the current scene.
Send appropriate scene data from a computer running
the DME Designer application.
No MAC Adr.
MAC address not specified.
This could be due do a hardware malfunction. Refer this
problem to a Yamaha service center or representative.
Panel Locked
Panel operation not allowed.
Press the [CANCEL] button for longer than 2 seconds to
disengage panel lock and allow panel operation.
Panel Unlocked
Panel lock has been disengaged. Panel operation is now
possible.
None required.
Recovering
A DME64N/24N program update attempt has failed, and
the previous program is currently being restored.
(Do not turn power off.)
After the program has been restored, try the update
operation again. If repeated update attempts fail, a
hardware malfunction may be the problem. Contact your
Yamaha service center or representative.
Saving HA Info
Head amplifier info save in progress.
(Do not turn power off.)
None required.
DME64N/24N Owner’s Manual
Appendix
Status messages
61
Error Messages
Message
Meaning
Info set up via the Utility display (other than head
amplifier info) is being saved.
(Do not turn power off.)
Scene Recalling
Scene recall in progress.
None required.
Scene Storing
Scene store in progress.
(Do not turn power off.)
None required.
SLOT1 Sync Err
The DME64N/24N clock is not synchronized with the
clock of the card installed in I/O slot 1.
Make sure that the DME64N/24N and the card installed
in I/O slot 1 are set to use the same word clock.
SLOT2 Sync Err
The DME64N clock is not synchronized with the clock of
the card installed in I/O slot 2.
Make sure that the DME64N and the card installed in I/O
slot 2 are set to use the same word clock.
SLOT3 Sync Err
The DME64N clock is not synchronized with the clock of
the card installed in I/O slot 3.
Make sure that the DME64N and the card installed in I/O
slot 3 are set to use the same word clock.
SLOT4 Sync Err
The DME64N clock is not synchronized with the clock of
the card installed in I/O slot 4.
Make sure that the DME64N and the card installed in I/O
slot 4 are set to use the same word clock.
WCLK Unlocked
A usable word clock signal is not being received or
cannot be detected.
Recheck all word clock connections and internal
parameters.
Zone Sync Err
The DME64N/24N contains data of another zone or no
data.
Send appropriate data from a computer running the DME
Designer application,
Appendix
62
Action
None required.
Saving Setup Info
DME64N/24N Owner’s Manual
Troubleshooting
Troubleshooting
Possible Causes
Possible Solutions
The power cord is not plugged into an
appropriate AC outlet.
Make sure that the power cord is plugged into an
appropriate AC outlet. Refer to “Preparation” on page 20.
The POWER switch is turned OFF.
Make sure that the POWER switch is turned ON. Refer to
“Preparation” on page 20.
There is a fault in the DME64N/24N.
Contact your Yamaha service center or representative.
The DME64N/24N power is not turned on.
Turn power to the DME64N/24N ON.
The DME Designer application is not running.
Launch the DME Designer application.
The connection cable is not connected properly.
Make sure that the connection cable is properly
connected.
The computer’s USB port is not functioning
properly (in the case of USB connection).
Refer to the DME Designer Installation Guide.
The computer’s Ethernet port is not functioning
properly (in the case of Ethernet connection).
Refer to the DME Designer Installation Guide.
Cannot recall a scene.
Appropriate scene data has not been stored in
the DME64N/24N.
Set up and store an appropriate scene in the DME64N/
24N. Use the DME Designer for scene setup.
The 96kHz/88.2kHz/48kHz/
44.1kHz indicators flash red.
The DME64N/24N is not synchronized to the
selected word clock.
Select a different word clock source. Refer to the “WCLK
Page” section on page 51.
The [WORD CLOCK IN] connector cable is
disconnected. Select the [WORD CLOCK IN]
connector as the word clock source.
Connect the cable.
An I/O card is not properly installed.
Make sure that an appropriate I/O card is inserted in an
I/O slot and that its screws are securely tightened. Refer
to “I/O Card Installation” on page 22 for details.
No communication between the
DME64N/24N and the DME
Designer application software.
No audio output.
No audio input is present.
Make sure that an audio input signal is present.
There is no scene data.
Store appropriate scene data in the DME64N/24N scene
memory. Use the DME Designer application for scene
setup.
The current scene is not properly wired to
produce audio output.
Redesign the scene to allow the desired audio output.
The mute function is engaged.
Disengage the mute function. Refer to “Mute Switching”
on page 42 for details.
The output level is set too low.
Increase the output level. Refer to “Output Level Control”
on page 42 for details.
The DME64N/24N is not synchronized to the
selected word clock.
Select a different word clock source. Refer to the “WCLK
Page” section on page 51.
You are attempting to run a scene that is not
compatible with 88.2/96 kHz operation at 88.2/
96 kHz.
Set the word clock to 44.1/48 kHz.
When an external device is
being used as the word clock
master and the word clock
source is changed, noise
appears at the analog outputs.
This is normal, and can occur when an MY8-AT
I/O card is being used.
Reduce the volume level of the power amplifier(s) to
prevent possible speaker damage, or make sure that the
DME64N/24N is off beforehand.
The selected scene changes
unexpectedly.
Scenes can be recalled via MIDI Program
Change message received from external
equipment if scene numbers are assigned to the
appropriate MIDI Program Change messages.
This is not a malfunction.
Use the DME Designer to check the MIDI Program
Change assignments.
Scenes can be recalled via trigger signals
received from external controllers connected to
the GPI interface if scene recall is assigned as a
GPI function.
Use the DME Designer application to check the GPI
input assignments.
This can happen if multiple user-defined
parameters are assigned to the same
parameter.
If it is likely to cause confusion, it may be better not to
assign more than one user-defined parameter to the
same parameter. User-defined parameter assignments
can be changed via the DME Designer application.
The parameter(s) may have been edited from
another DME64N/24N in the same zone.
Use the Panel Lock function (described on page 39) to
prevent unwanted operation from specific DME64N/24N
units or ICP1 control panels.
The parameter may be assigned to a MIDI
Control Change message via which it can be
edited from an external device.
Use the DME Designer application to check the MIDI
Control Change assignments.
The parameter may be assigned to GPI control
from an external controller connected to the GPI
interface.
Use the DME Designer application to check the GPI
input assignments.
User-defined parameter
settings change unexpectedly.
DME64N/24N Owner’s Manual
Appendix
Symptom
The DME64N/24N power won’t
turn on.
63
Troubleshooting
Symptom
Possible Solutions
Disengage the Panel Lock function. Refer to the “Panel
Lock” section on page 39.
No DME64N/24N is assigned as the zone
master.
For each zone one DME64N/24N must be assigned as
the zone master. This can be accomplished via the Utility
display “Net” page described on page 48 of this
document.
The IP address is not set properly.
Set an appropriate IP address. This can be
accomplished via the Utility display “Net” page
described on page 48 of this document.
User-defined parameters
cannot be edited.
The user-defined parameter lock function is
engaged.
Disengage the user-defined parameter lock function.
This can be accomplished via the Utility display “Lock”
page described on page 50 of this document.
Scenes can be recalled but not
stored.
The scene store parameter is set to “Disable.”
Set the scene store parameter to “Enable.” This can be
accomplished via the Utility display “Lock” page
described on page 50 of this document.
Can’t open the Utility display.
The Utility display lock function is engaged.
Disengage the Utility display lock function. This can be
accomplished via the Utility display “Lock” page
described on page 50 of this document. If you have
forgotten your password contact your Yamaha service
center or representative.
MIDI messages cannot be
transmitted or received.
The connection cable is not properly connected.
Make sure the connection cable is connected properly.
Power to the MIDI device is not turned on.
Turn power to the MIDI device on.
Set the MIDI transmit/receive channel of the
MIDI device to match the DME64N/24N channel
setting(s).
Set the MIDI device MIDI channel appropriately.
The DME64N/24N MIDI parameters are not set
up properly.
Properly set up the DME64N/24N MIDI parameters. MIDI
setup can be accomplished via the Utility display “MIDI”
page, as described on page 52 of this document.
The MIDI settings may not be properly set up to
allow Program Change message reception.
Make sure that the MIDI receive channel and other MIDI
parameters are set up to allow Program Change
message reception. MIDI setup can be accomplished
via the Utility display “MIDI” page, as described on page
52 of this document.
The appropriate scene numbers are not
assigned to the Program Change numbers
being received.
Use the DME Designer application to assign the
appropriate scene numbers to Program Change
messages.
There is no data in the scene you are attempting
to recall (only scenes containing data can be
recalled).
Use the DME Designer application to create scene data
that can be recalled.
The MIDI Program Change table has not been
set up.
Use the DME Designer to set up the MIDI Program
Change Table as required.
The MIDI settings may not be properly set up to
allow Control Change message reception.
Make sure that the MIDI receive channel and other MIDI
parameters are set up to allow Control Change message
reception. MIDI setup can be accomplished via the Utility
display “MIDI” page, as described on page 52 of this
document.
The MIDI Control Change table has not been set
up.
Use the DME Designer to set up the MIDI Control
Change Table as required.
The MIDI parameters may not be properly set up
to allow Parameter Change message reception.
Make sure that the MIDI receive channel and other MIDI
parameters are set up to allow Parameter Change
message reception. MIDI setup can be accomplished
via the Utility display “MIDI” page, as described on page
52 of this document.
The MIDI Parameter Change table has not been
set up.
Use the DME Designer to set up the MIDI Parameter
Change Table as required.
The audio signal sounds slightly
out of synchronization.
The Cascade connection unit number setting is
incorrect.
Set the correct unit number of the cascaded units. This
can be accomplished via the Utility display “CASCAD”
page, as described on page 55 of this document.
The headphone output is not
muted when the [MUTE] button
is pressed.
This is normal.
The level of the headphone output can be reduced by
using the [PHONES LEVEL] control (but cannot be muted
completely).
AD824 or AD8HR cannot be
selected from the HA setting in
the HA page.
The connecting cable has not been properly
connected to the [REMOTE] terminal.
Make sure that the cable is properly connected.
Scenes cannot be recalled via
MIDI Program Change
messages.
Appendix
Parameters cannot be edited
via MIDI Control Change
messages.
Parameters cannot be edited
via MIDI Parameter Change
messages.
64
Possible Causes
The Panel Lock function is engaged.
The panel controls don’t work.
The AD8HR/AD824 power is not turned on.
Turn on the power of the AD8HR/AD824.
The “Remote” parameter is set to “COM
(RS232C).”
Turn off the AD8HR/AD824 and set “HA Control (RS422)”
for the Remote setting in the “Misc” page, then turn on
the AD8HR/AD824.
DME64N/24N Owner’s Manual
Specifications
Specifications
Specifications and descriptions in this owner’s manual are for information purposes only. Yamaha Corp. reserves the right to
change or modify products or specifications at any time without prior notice. Since specifications, equipment or options may not
be the same in every locale, please check with your Yamaha dealer.
Sampling Frequency
Internal
44.1kHz, 48kHz, 88.2kHz, 96kHz
External
Normal Rate: 39.69 – 50.88kHz
Double Rate: 79.39 – 101.76kHz
Signal Delay (Fs = 96kHz)
Memory
DME64N: 0.85 msec (Input of MY8-AD96 to Output of MY8-DA96)
DME24N: 0.5 msec ([IN] port to [OUT] port)
Configuration
16 (depends on size of data)
Scene
999 (depends on size of data)
Display
160 x 64 dot matrix LCD with backlight
Scene No.
7-segment LED x 3
Indicators
Wordclock
EXT.CLOCK, 96kHz, 88.2kHz, 48kHz, 44.1kHz
External Control
NETWORK, MIDI
Zone Configuration
MASTER
Analog Input*1
SIGNAL x 8, PEAK x 8
Analog Output*1
SIGNAL x 8, PEAK x 8
Power Requirements
120V AC, 60Hz (USA, Canada)
230V AC, 50Hz (Europe)
100V AC, 50/60Hz (Japan)
Power Consumption
DME64N: 80W
DME24N: 75W
Dimensions (W x H x D)
DME64N: 480 x 145 x 411.5mm, 3U
DME24N: 480 x 101 x 411.5mm, 2U
Weight
DME64N: 9.5kg
DME24N: 8kg
Temperature Range
Free-Air operating
10 – 35 °C
Storage
-20 – 60 °C
AC Power Cord Length
2.5m
Supplied Accessories
AC power cord, CD-ROM (DME Designer application), Owner’s
Manual, DME Designer Installation Guide, AC plug clamp, 16-pin
Euroblock plug x 2, 8-pin Euroblock plug x 4 (DME64N), 3-pin
Euroblock plug x 16 (DME24N)
*1. Available on DME24N only
Appendix
European models
Purchaser/User Information specified in EN55103-1 and EN55103-2.
Inrush Current: 39A
Conforms to Environments: E1, E2, E3 and E4
Control I/O
Terminals
REMOTE
Format
Level
-
RS232C
Connector
D-SUB Connector 9-pin (Male)
-
RS422
MIDI
IN/OUT/THRU
-
DIN Connector 5P
WORDCLOCK
IN/OUT
TTL/75Ω
BNC Connector
Ethernet
Ethernet
-
RJ-45
USB
USB
0 – 3.3V
USB Type B (Male)
GPI
IN
0 – 5V
Euroblock Connector
OUT
TTL
+V
5V
DME64N: 16-GPI inputs and 16-GPI outputs
DME24N: 8-GPI inputs and 8-GPI outputs
DME64N/24N Owner’s Manual
65
Connector Pin Assign
Connector Pin Assign
[CASCADE IN/OUT] Connectors (DME64N only)
CASCADE IN
Pin
No.
Appendix
66
CASCADE OUT
Signal
Pin
No.
Signal
Pin
No.
Signal
Pin
No.
Signal
1
GND
35
GND
1
GND
35
GND
2
INPUT 1-2 (+)
36
INPUT 1-2 (-)
2
OUTPUT 1-2 (+)
36
OUTPUT 1-2 (-)
3
INPUT 3-4 (+)
37
INPUT 3-4 (-)
3
OUTPUT 3-4 (+)
37
OUTPUT 3-4 (-)
4
INPUT 5-6 (+)
38
INPUT 5-6 (-)
4
OUTPUT 5-6 (+)
38
OUTPUT 5-6 (-)
5
INPUT 7-8 (+)
39
INPUT 7-8 (-)
5
OUTPUT 7-8 (+)
39
OUTPUT 7-8 (-)
6
INPUT 9-10 (+)
40
INPUT 9-10 (-)
6
OUTPUT 9-10 (+)
40
OUTPUT 9-10 (-)
7
INPUT 11-12 (+)
41
INPUT 11-12 (-)
7
OUTPUT 11-12 (+)
41
OUTPUT 11-12 (-)
8
INPUT 13-14 (+)
42
INPUT 13-14 (-)
8
OUTPUT 13-14 (+)
42
OUTPUT 13-14 (-)
9
INPUT 15-16 (+)
43
INPUT 15-16 (-)
9
OUTPUT 15-16 (+)
43
OUTPUT 15-16 (-)
10
DTR IN (+)
44
DTR IN (-)
10
DTR OUT (+)
44
DTR OUT (-)
11
RTS OUT (+)
45
RTS OUT (-)
11
RTS IN (+)
45
RTS IN (-)
12
GND
46
GND
12
GND
46
GND
13
WORD CLOCK IN (+)
47
WORD CLOCK IN (-)
13
WORD CLOCK OUT (+)
47
WORD CLOCK OUT (-)
14
WORD CLOCK OUT (+)
48
WORD CLOCK OUT (-)
14
WORD CLOCK IN (+)
48
WORD CLOCK IN (-)
15
CONTROL IN (+)
49
CONTROL IN (-)
15
CONTROL OUT (+)
49
CONTROL OUT (-)
16
CONTROL OUT (+)
50
CONTROL OUT (-)
16
CONTROL IN (+)
50
CONTROL IN (-)
17
GND
51
ID6 IN
17
GND
51
ID6 OUT
18
GND
52
ID6 OUT
18
GND
52
ID6 IN
19
INPUT 17-18 (+)
53
INPUT 17-18 (-)
19
OUTPUT 17-18 (+)
53
OUTPUT 17-18 (-)
20
INPUT 19-20 (+)
54
INPUT 19-20 (-)
20
OUTPUT 19-20 (+)
54
OUTPUT 19-20 (-)
21
INPUT 21-22 (+)
55
INPUT 21-22 (-)
21
OUTPUT 21-22 (+)
55
OUTPUT 21-22 (-)
22
INPUT 23-24 (+)
56
INPUT 23-24 (-)
22
OUTPUT 23-24 (+)
56
OUTPUT 23-24 (-)
23
INPUT 25-26 (+)
57
INPUT 25-26 (-)
23
OUTPUT 25-26 (+)
57
OUTPUT 25-26 (-)
24
INPUT 27-28 (+)
58
INPUT 27-28 (-)
24
OUTPUT 27-28 (+)
58
OUTPUT 27-28 (-)
25
INPUT 29-30 (+)
59
INPUT 29-30 (-)
25
OUTPUT 29-30 (+)
59
OUTPUT 29-30 (-)
26
INPUT 31-32 (+)
60
INPUT 31-32 (-)
26
OUTPUT 31-32 (+)
60
OUTPUT 31-32 (-)
27
ID0 IN
61
ID1 IN
27
ID0 OUT
61
ID1 OUT
28
ID2 IN
62
ID3 IN
28
ID2 OUT
62
ID3 OUT
29
ID4 IN
63
ID5 IN
29
ID4 OUT
63
ID5 OUT
30
ID0 OUT
64
ID1 OUT
30
ID0 IN
64
ID1 IN
31
ID2 OUT
65
ID3 OUT
31
ID2 IN
65
ID3 IN
32
ID4 OUT
66
ID5 OUT
32
ID4 IN
66
ID5 IN
33
MSB //LSB IN
67
2CH//4CH IN
33
MSB //LSB OUT
67
2CH//4CH OUT
34
FG
68
FG
34
FG
68
FG
DME64N/24N Owner’s Manual
Connector Pin Assign
[NETWORK] Connector (100Base-TX Ethernet, RJ-45)
Pin
Connection
1
TxD+
2
TxD–
3
RxD+
4
Unused
5
Unused
6
RxD–
7
Unused
8
Unused
Straight/Cross Cable Wiring Details
Cross Cables
Pins
Pins
1 —— 1
1 —— 3
2 —— 2
2 —— 6
3 —— 3
3 —— 1
4 —— 4
4 —— 4
5 —— 5
5 —— 5
6 —— 6
6 —— 2
7 —— 7
7 —— 7
8 —— 8
8 —— 8
Appendix
Straight Cables
DME64N/24N Owner’s Manual
67
Dimensions
Dimensions
Unit: mm
12.5
53.5
278
388
411.5
394
405
11
DME64N
423
145
17.5
96
132
18.5
4-M3
90
30
300
90
480
11
DME24N
12.5
53.5
278
388
411.5
394
405
Appendix
423
90
68
DME64N/24N Owner’s Manual
300
480
30
90
101
18 52
88
18
4-M3
MIDI Data Format
MIDI Data Format
1. DME64N/24N MIDI Functions
1.1 Scene Change
Scene recall occurs according to the “MIDI Program Change Table” assignments when appropriate MIDI Bank Select
MSB/LSB and Program Change messages are received by the DME64N/24N.
Corresponding MIDI Bank Select MSB/LSB and Program Change messages are also transmitted by the DME64N/24N
when a scene recall operation is carried out via the panel controls, as specified by the “MIDI Program Change Table”
assignments.
Transmission does not occur when switching Configurations.
1.2 Parameter Control
MIDI Control Change and Parameter Change messages transmitted to the DME64N/24N can be used to control
parameters according to the “MIDI Control Change table” and “MIDI Parameter Change Table” assignments.
Corresponding MIDI Control Change and Parameter Change messages are also transmitted by the DME64N/24N when a
parameter is edited out via the panel controls, as specified by the “MIDI Control Change table” and “MIDI Parameter
Change Table” assignments.
1.3 MIDI Clock
BPM (beats per minute) based parameters can be controlled by a MIDI clock signal transmitted to the DME64N/24N.
“MIDI Program Change Table,” “MIDI Control Change Table,” and “MIDI Parameter Change Table” assignments can be
made via the DME Designer application. Refer to the DME Designer Manual for details.
MIDI IN
MIDI Rx CH
SW1
Bank Select MSB/LSB
Program Change
(Scene Recall)
SW2
Control Change
(Parameter Edit)
SW3
Parameter Change
(Parameter Edit)
Appendix
2. MIDI Data Flow
Bank Select MSB/LSB
Program Change
(Echo Back)
SW4
Control Change
(Echo Back)
SW5
Parameter Change
(Echo Back)
SW6
Bank Select MSB/LSB
Program Change
Control Change
SW7
MIDI Tx CH
MIDI OUT
SW8
Parameter Change
SW9
MIDI THRU
SW1:
SW2:
SW3:
SW4:
SW5:
SW6:
SW7:
SW8:
SW9:
MIDI
MIDI
Program Change Rx Switch [On/Off]
Control Change Rx Switch [On/Off]
Parameter Change Rx Switch [On/Off]
Program Change Echo Back Switch [On/Off]
Control Change Echo Back Switch [On/Off]
Parameter Change Echo Back Switch [On/Off]
Program Change Tx Switch [On/Off]
Control Change Tx Switch [On/Off]
Parameter Change
Rx CH: MIDI Rx Channel (1-16)
Tx CH: MIDI Tx Channel (1-16)
DME64N/24N Owner’s Manual
69
MIDI Data Format
3. MIDI Setup
Specifies basic MIDI operation.
3.1 Host Select
Selects the input/output port to be used for MIDI communication.
3.2 DAW Controller
Specifies the DAW controller type when a DAW control surface is to be used to control the DME64N/24N. When Type 1/
2 is selected, Host Select is automatically set to MIDI.
3.3 MIDI Tx Channel
Specifies the MIDI transmit channel (1 ~ 16).
3.4 MIDI Rx Channel
Specified the MIDI receive channel (1 ~ 16).
3.5 MIDI Tx Switch
Program Change Tx Switch: turns Bank Select MSB, LSB, and Program Change transmission on or off.
Control Change Tx Switch: turns Control Change transmission on or off.
Parameter Change Tx Switch: turns Parameter Change transmission on or off.
3.6 MIDI Rx Switch
Program Change Rx Switch: turns Bank Select MSB, LSB, and Program Change reception on or off.
Control Change Rx Switch: turns Control Change reception on or off.
Parameter Change Rx Switch: turns Parameter Change reception on or off.
3.7 MIDI Omni Switch
Program Change Omni Switch: turns the Bank Select MSB, LSB, and Program Change omni mode on or off.
Control Change Omni Switch: turns the Control Change omni mode on or off.
3.8 MIDI Echo Back Switch
Program Change Echo Back Switch: turns Bank Select MSB, LSB, and Program Change echo back on or off.
Control Change Echo Back Switch: turns Control Change echo back on or off.
Parameter Change Echo Back Switch: turns Parameter Change echo back on or off.
4. MIDI Format
Appendix
Number Format Notation
Numbers ending with “h” are in hexadecimal format, while numbers ending with “b” are binary format. Characters “A”
through “F” in hexadecimal numbers represent decimal values 10 through 15. Other lowercase characters (usually “n” or “x”)
represent any number.
MIDI Format Chart (Rx: receive, Tx: transmit)
Command
Channel Message
System Real-time Message
System Exclusive Message
70
DME64N/24N Owner’s Manual
Rx/Tx
Function
Control Change (Bnh)
Rx/Tx
Parameter Change
Program Change (Cnn)
Rx/Tx
Scene Recall
TIMING CLOCK (F8h)
Rx
MIDI Clock Receive
ACTIVE SENSING (FEH)
Rx
MIDI Cable Check
Parameter Change
Rx/Tx
Parameter Change
MIDI Data Format
4.1 Program Change (Cnh)
Receive
When the “Program Change Rx Switch” is on, Program Change messages are received on the MIDI channel specified by
the “MIDI Rx Channel” parameter.
If the “Program Change Omni Switch” is also on, however, Program Change messages will be received on all MIDI
channels regardless of the “MIDI Rx Channel” setting.
When a Program Change message is received, the scene assigned to the received program number in the “MIDI Program
Change table” is recalled.
The accepted Bank Select, Program Change range is as follows:
Bank Select MSB: 0
Bank Select LSB: 0 ~ 7
Program Change No.: 0 ~ 127
Transmit
When the “Program Change Tx Switch” is on, the corresponding Program Change number will be transmitted as specified
by the “MIDI Program Change table” and “MIDI Tx Channel” settings.
Transmission does not occur when switching Configurations.
If multiple Program Change numbers are assigned to a single scene, the Bank Select MSB/LSB and Program Change
number corresponding to the lowest number will be transmitted.
Bank Select MSB
Status
Bnh (1101nnnnb)
Control Change
Data
00h (00000000b)
Control Change No. 0 (Bank Select MSB)
Data
nnh (0nnnnnnnb)
Control Value (Bank Select MSB No.)
Bank Select LSB
Status
Bnh (1101nnnnb)
Control Change
Data
20h (00100000b)
Control Change No. 32 (Bank Select LSB)
nnh (0nnnnnnnb)
Control Value (Bank Select LSB No.)
Program Change No.
Status
Cnh (1100nnnnb)
Program Change
Data
nnh (0nnnnnnnb)
Program Change No. (0-127)
4.2 Timing Clock (F8h)
Receive
Controls parameters that depend on the MIDI clock signal.
Timing Clock
F8h (11111000b)
Timing Clock
Appendix
Status
4.3 Active Sensing (FEh)
Receive
MIDI communication will be initialized if no data is received within 300 ms after reception (Running Status, etc., will be
cleared).
Active Sensing
Status
FEh (11111110b)
Active Sensing
4.4 Control Change (Bnh)
Receive
When the “Control Change Rx Switch” is on, Control Change messages are received on the MIDI channel specified by the
“MIDI Rx Channel” parameter.
If the “Control Change Omni Switch” is also on, however, Control Change messages will be received on all MIDI channels
regardless of the “MIDI Rx Channel” setting.
Control Change parameter resolution is 128 regardless of the parameters effective range. For finer settings use Parameter
Change.
Transmit
When the “Control Change Tx Switch” is on, appropriate Control Change data will be transmitted when a parameter is
edited via the panel controls, as specified by the “MIDI Control Change table” and “MIDI Tx Channel” settings.
Transmission does not occur when switching Configurations.
Refer to “Supplementary Information 1” for cases in which multiple messages are assigned to single parameter.
Status
Bnh (1011nnnnb)
Control Change
Data
cch (0cccccccb)
Control Change No. (1-31,33-95,102-119)
vvh (0vvvvvvvb)
Control Value (0-127)
DME64N/24N Owner’s Manual
71
MIDI Data Format
4.5 Parameter Change (F0h ~ F7h)
Receive
When the “Parameter Change Rx Switch” is On, Parameter Change messages are received on the MIDI channel specified
by the “Device ID (Rx Ch)” parameter.
Transmit
When the “Parameter Change Tx Switch” is On, appropriate Parameter Change data will be transmitted when a parameter
is edited via the panel controls, as specified by the “MIDI Parameter Change table” and “MIDI Tx Channel” settings.
Refer to “Supplementary Information 1” for cases in which multiple messages are assigned to single parameter.
Refer to “Supplemental Information 2” for information on setting Parameter Data values.
Status
ID No.
DEVICE ID.
GROUP ID.
MODEL ID.
Parameter
Address
F0h
43h
10h
3Eh
10h
aah
aah
ddh
ddh
ddh
ddh
ddh
F7h
Parameter
Data Value
EOX
(11110000b)
(01000011b)
(0001xxxxb)
(00111110b)
(00010000b)
(0aaaaaaab)
(0aaaaaaab)
(0dddddddb)
(0dddddddb)
(0dddddddb)
(0dddddddb)
(0dddddddb)
(11110111b)
System Exclusive Message
Manufacturer's ID No.(YAMAHA)
Rx/Tx Channel (0-15)
Digital Mixer
Device Code (DME)
Parameter Address High
Parameter Address Low
data 0
data 1
data 2
data 3
data 4
End of Exclusive
Supplemental Information 1
Messages Transmitted When Multiple Messages are Assigned to the Same Parameter
The DME64N/24N MIDI transmit messages are specified via the “MIDI Control Change Table” and “MIDI Parameter
Change Table.” The “MIDI Control Change Table” and “MIDI Parameter Change Table” can be set up via the DME
Designer application.
Multiple messages can be assigned to a single parameter, but the DME64N/24N will only transmit one of the assigned
messages.
The transmitted messages are as follows:
• If a Control Change message and a Parameter Change message are assigned to the same parameter → the Control Change
message will be transmitted.
• If multiple Control Change numbers are assigned to the same parameter → the smallest Control Change number
message will be transmitted.
• If multiple Parameter Change numbers are assigned to the same parameter → the smallest Parameter Change number
message will be transmitted.
Supplemental Information 2
Appendix
Setting the Parameter Change Message Parameter Data Values
The Parameter change parameter values are expressed as 32-bit integers with or without parity.
• A parity bit (positive: 0, negative: 1) is added above the most significant value bit (bit 31).
• Fractional parameters will be converted according to the integer table.
• For integers with parity, negative numbers are expressed as the 2’s complement.
bit0
bit1
bit2
bit3
bit4
bit5
bit6
bit7
bit8
bit9
bit10
bit11
bit12
bit13
bit14
bit15
bit16
bit17
bit18
bit19
bit20
bit21
bit22
bit23
bit24
bit25
bit26
bit27
bit28
bit29
bit30
bit31
sign
0 0
data 0
data 1
data 2
data 3
data 4
Example
• When value is 1000 (decimal) / 3E8h (hexadecimal):
+
0
0
0
0
0
3
E
8
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 0 1 0 0 0
data 0 = 00h
data 1 = 00h
data 2 = 00h
data 3 = 07h
data 4 = 68h
• When value is 1000 (decimal) / FFFFFC18h (hexadecimal; 2’s complement of 3E8h):
-
F
F
F
F
F
C
1
8
0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 1 1 0 0 0
data 0 = 1Fh
72
DME64N/24N Owner’s Manual
data 1 = 7Fh
data 2 = 7Fh
data 3 = 78h
data 4 = 18h
MIDI Data Format
YAMAHA
[Digital Mixing Engine]
Model DME64N/24N MIDI Implementation Chart
Function...
Transmitted
Recognized
Basic
Channel
Default
Changed
1 - 16
1 - 16
1 - 16
1 - 16
Mode
Default
Messages
Altered
˛
˛
˛
˛
˛
Note
Number : True voice
**************
**************
Note ON ˛
Note OFF ˛
˛
˛
After
Touch
Key's
Ch's
˛
˛
˛
˛
Ø
Ø
0,32
1-31,33-95,102-119
*1
*2
Ø
Ø
0 - 127
*1
**************
Ø
*3
Ø
Ø
Ø
Remarks
Memorized
˛
˛
˛
Velocity
Pitch Bend
Date :31-MAR-2004
Version : 1.0
*1
*2
Bank Select
Assignable
Control
Prog
Change
Ø
:
True #
System Exclusive
Common
Ø
: Song Pos. ˛
: Song Sel. ˛
˛
: Tune
˛
˛
Ø
˛
:
:
:
Mes- :
sages:
:
˛
˛
˛
˛
˛
˛
˛
˛
˛
˛
Ø
Ø
Notes:
All Sound Off
Reset All Cntrls
Local ON/OFF
All Notes OFF
Active Sense
Reset
*1
*3
˛
˛
˛
System
: Clock
Real Time : Commands
Aux
0 - 127
0 - 127
Appendix
Change
not include "DAW controller" command
*1 transmit/receive if program change switch is on.
*2 transmit/receive if control change switch is on.
*3 transmit/receive if parameter change switch is on.
Mode 1 : OMNI ON , POLY
Mode 3 : OMNI OFF, POLY
Mode 2 : OMNI ON ,MONO
Mode 4 : OMNI OFF,MONO
Ø
˛
: Yes
: No
DME64N/24N Owner’s Manual
73
Glossary
Glossary
Terms
Appendix
74
Explanations
100Base-TX
A physical specification for a 100 Mbps Ethernet network connection using 2-conductor
Category 5 UTP cable included in the IEEE 802.3u standard. Maximum data transfer
distance is 100 meters.
10Base-T
A physical specification for a 10 Mbps Ethernet network connection using 2-conductor
Category 3 UTP cable included in the IEEE 802.3i standard. Maximum data transfer
distance is 100 meters.
ADAT (Alesis Digital Audio Tape)
A digital audio connection format used by ADAT compliant digital audio devices. Eight
channels of digital audio can be carried by a single optical “Tos-Link” cable.
AES/EBU (Audio Engineering Society/
European Broadcasting Union)
A digital audio format jointly devised by the AES and EBU. Used primarily for digital audio
transfer between professional equipment. Two channels of digital audio can be handled via
a single connector (Left: odd number, Right: even number). Standard XLR connectors are
generally used for this type of connection.
BNC (Bayonet Nut Connector,
or Bayonet Neill Concelman)
A type of connector used for high-frequency connections using thin-core coaxial cable.
An internal spring ensures a solid connection.
Cascade
A means of connecting Yamaha digital audio equipment to allow transfer of audio, control,
and word clock signals. Yamaha cascade connections employ half-pitch 68-pin D-Sub
connectors.
Category 3
Electrical specifications for one type of UTP cable jointly developed by the TIA
(Telecommunications Industry Association) and EIA (Electronic Industry Alliance). Several
categories are specified according to electrical characteristics, with higher category
numbers denoting higher quality cable. Category 3 cable can be used for transmission
speeds up to 10 MHz.
Category 5
Electrical specifications for one type of UTP cable jointly developed by the TIA
(Telecommunications Industry Association) and EIA (Electronic Industry Alliance). Several
categories are specified according to electrical characteristics, with higher category
numbers denoting higher quality cable. Category 5 cable can be used for transmission
speeds up to 100 MHz.
CobraNet
An audio networking system developed by Peak Audio (a division of Cirrus Logic, Inc.) that
allows real-time transmission and reception of multiple channels of uncompressed digital
audio signals via a Fast Ethernet (100 megabits/sec.) network.
Component
The basic modules that are combined to create DME64N/24N audio systems. In addition to
complete audio processors such as mixers, compressors, effects, crossovers, etc., a range
of smaller functions such as faders, switches, pan controls, and meters are also available.
Components can also be customized.
Configuration
A set of components and connections that make up an audio system in the DME64N/24N.
D-Sub
Another common form of connector that gets its name from the “D” shape of the connector.
This type of connector can be securely attached using screws. Individual “pins” are used to
connect each of the cable’s conductors. D-Sub connectors come in 9-pin, 15-pin, 25-pin,
37-pin, and other sizes.
DSP (Digital Signal processor)
A semiconductor chip (LSI), or device containing one or more such chips, developed
specifically to process large volumes of data in real time. Ideal for processing digital audio.
Ethernet
A network protocol jointly developed by the Xerox, DEC, and Intel corporations, and
codified in the IEEE 802.3 industry standard. Transfer speeds have increased to 100 Mbps,
1000 Mbps, and 10 Gbps from the initial 10 Mbps, while maintaining network compatibility.
Euroblock
A connector system consisting of plug and socket components that allows easy, solder-less
wiring for a range of installations and devices. Simply insert the wire into the plug slot,
tighten the screw, and plug into the socket to complete the connection.
GPI (General Purpose Interface)
A general-purpose control interface that can be used to allow control of the DME64N/24N
via external devices and custom-made controllers. Connections are made via a Euroblock
connector. The optional CP4SW, CP1SF, and CP4SF control panels also connect via GPI.
Initial Settings
The initial values and settings of all editable parameters that will be in effect when a device
is powered on for the first time after it is shipped from the factory. Also known as “default
settings” or “initial factory settings.”
MAC (Media Access Control) Address
The MAC address is also known as the Ethernet address, and is an independent address
assigned to all Ethernet devices worldwide. No two devices can have the same address.
MIDI (Musical Instrument Digital Interface)
An international standard for data communication between electronic musical instruments
and audio devices.
Mini YGDAI (Yamaha General Digital Audio
Interface) card
A standard for I/O cards that can be installed to Yamaha audio products.
Phantom Power
A power delivery system that allows power to be delivered to devices along with audio
signals via standard balanced audio cables. The term “phantom” is applied because the
system uses the audio conductors for power delivery without disrupting the audio signal
– the power is not “seen” by the audio signal.
Preset Parameter
The parameter set of all components included in a configuration.
DME64N/24N Owner’s Manual
Glossary
Terms
Explanations
An 8-conductor modular connector used for Ethernet cable and ISDN telephone
connections. The appearance is similar to the RJ-11 connectors used for telephone lines,
but the connector is actually somewhat larger. “RJ” stands for “Registered Jack,” and is a
connector type included in the Bell System USOC (Universal Service Ordering Codes)
standards.
Router
An equipment that relays data in network by selecting the most effective route.
RS-232C
A serial communication protocol that allows data transfer over distances of up to 15 meters.
RS232C interfaces usually employ 9-pin D-sub connectors. “RS” stands for
“Recommended Standard,” and one of the standards developed by the EIA (Electronic
Industry Alliance).
RS-422
A balanced serial communication protocol that allows data transfer over distances of up to
1 kilometer. RS-422 offers higher data rates and greater reliability than the RS-232C
protocol.
Sampling Frequency
The number of times per second an analog audio signal is “sampled” when it is being
converted to digital audio.
Scene
A complete audio setup including configuration data and the related component preset
parameters. Up to 999 scenes can be stored for each zone in a DME64N/24N audio
system.
STP (Shielded Twisted Pair) Cable
A data transmission cable consisting of a shielded twisted pair. This type of cable is more
resistant to noise and interference than UTP (Unshielded Twisted Pair) cable.
Switching Hub
A network hub which automatically connects only ports through which communication is
currently taking place. This reduces network load while maximizing security. This type of
hub can often mediate between devices having different transmission speeds and
standards.
TDIF (Tascam Digital Interface Format)
A digital interface standard used by the TEAC corporation (TASCAM). Eight channels of
digital audio input and output are handled via a 25-pin D-Sub connector.
USB (Universal Serial Bus)
A serial bus primarily used for connecting peripheral devices to computer equipment.
The USB 1.1 standard allows data transfer rates of up to 12 Mbps.
UTP (Unshielded Twisted pair) Cable
A data transmission cable consisting of an unshielded twisted pair. This type of cable is
less expensive and more commonly available than STP (Shielded Twisted Pair) cable, and
is widely used in 10Base-T and 100Base-TX network connections.
Word Clock
A signal used to synchronize multiple interconnected digital audio devices. The word clock
frequency will be the same as the sampling frequency of the audio signal being processed.
Appendix
RJ-45
DME64N/24N Owner’s Manual
75
Index
Index
+48V ...................................................................................... 55
[E] [ ▲ ] [ ▼ ] [F] Buttons ........................................... 17
100Base-TX (Glossary) .......................................................... 74
10Base-T (Glossary) ............................................................... 74
[96kHz] [88.2kHz] [48kHz] [44.1kHz] Indicator ................. 16
A
[AC IN] Connector ............................................................... 18
ADAT (Alesis Digital Audio Tape) (Glossary) ....................... 74
AES/EBU (Audio Engineering Society/European Broadcasting
Union) (Glossary) .................................................................. 74
area ........................................................................................ 13
audio ...................................................................................... 24
B
Band Output Level ................................................................ 45
Battery ................................................................................... 48
BNC (Bayonet Nut Connector, or Bayonet Neill Concelman)
(Glossary) ............................................................................... 74
C
Appendix
cable clamp ............................................................................ 20
Calibration Info ..................................................................... 53
[CANCEL] Button ................................................................ 17
[CANCEL] Button (ICP1) .................................................... 57
Card Name ............................................................................ 52
CASCAD Page ....................................................................... 55
Cascade (Glossary) ................................................................. 74
Cascade (WCLK Page) ........................................................... 51
CASCADE connection .......................................................... 32
[CASCADE IN] [CASCADE OUT] Connectors ............ 19, 32
cascade loop ........................................................................... 32
Cascade Setup (CASCAD) Page ............................................. 55
Category 3 (Glossary) ............................................................. 74
Category 5 (Glossary) ............................................................. 74
CH (Double Channel) (Slot Page) ......................................... 52
CH (MIDI Page) ................................................................... 53
CobraNet (Glossary) .............................................................. 74
CobraNet connection ............................................................ 37
component ............................................................................. 14
component (Glossary) ............................................................ 74
configuration ......................................................................... 14
configuration (Glossary) ......................................................... 74
connection ............................................................................. 24
connector pin assign ............................................................... 66
Control Change ..................................................................... 53
control I/O ............................................................................ 65
CP1SF ................................................................................... 59
CP4SF ................................................................................... 59
CP4SW .................................................................................. 59
76
DME64N/24N Owner’s Manual
D
Date .......................................................................................48
DAW .....................................................................................52
device control .........................................................................24
Dial ........................................................................................17
dimensions .............................................................................68
Disp Page ...............................................................................49
Display ...................................................................................17
Display Setup (Disp) Page ......................................................49
DME Designer .......................................................................15
DME-N Network driver .........................................................27
DSP (Digital Signal processor) (Glossary) ...............................74
D-Sub (Glossary) ....................................................................74
E
[ENTER] Button ...................................................................17
[ENTER] Button (ICP1) .......................................................57
error message ..........................................................................61
Ethernet (Glossary) .................................................................74
Ethernet connection ...............................................................27
Euroblock ...............................................................................35
Euroblock (Glossary) ..............................................................74
[EXT. CLOCK] Indicator ......................................................16
F
[F1] Button (ICP1) ................................................................56
[F2] Button (ICPI) .................................................................56
[F3] Button (ICP1) ................................................................56
[F4/UTILITY] Button (ICP1) ................................................56
[F5] Button (ICP1) ................................................................57
[F6/MUTE] Button (ICP1) ...................................................57
Format (HA Page) ..................................................................54
Format (Slot Page) ..................................................................52
Frequency ...............................................................................45
front panel ..............................................................................16
Frq .........................................................................................55
Fs ...........................................................................................51
G
Gain .......................................................................................55
GPI (General Purpose Interface) .............................................31
GPI (General Purpose Interface) (Glossary) ............................74
GPI connection ......................................................................31
[GPI] Connector ..............................................................18, 31
Ground Screw ........................................................................18
H
HA .........................................................................................54
HA Page .................................................................................54
Head Amplifier Setup (HA) Page ...........................................54
Head Margin ..........................................................................55
High-pass Filter ......................................................................55
High-pass Filter Frequency .....................................................55
Index
I
I/O card ................................................................................. 22
I/O card (installation procedure) ............................................ 23
I/O Slots ................................................................................ 19
ICP1 ...................................................................................... 56
[IN] [OUT] Connectors .................................................. 19, 35
Info Page ................................................................................ 48
initial settings (Glossary) ........................................................ 74
Input/Output Level Display ................................................... 46
Int .......................................................................................... 51
IP Adr. ................................................................................... 49
L
L/R Select .............................................................................. 45
LCD Backlight ....................................................................... 49
LCD Contrast ........................................................................ 49
[LEVEL] Button .................................................................... 17
Level Meter display ................................................................ 46
Link Mode ............................................................................. 49
List Parameter ........................................................................ 41
Lock Page .............................................................................. 50
M
MAC (Media Access Control) Address (Glossary) .................. 74
MAC Adr. .............................................................................. 49
Main display .......................................................................... 39
[MASTER] Indicator ............................................................. 17
MAX ...................................................................................... 53
Meter Fall Time ..................................................................... 49
MIDI (Musical Instrument Digital Interface) (Glossary) ........ 74
MIDI connection ................................................................... 30
MIDI Data Format ................................................................ 69
[MIDI IN] [MIDI OUT] [MIDI THRU] Connectors .......... 19
[MIDI] Indicator ................................................................... 17
MIDI Page ............................................................................. 52
MIDI Setup (MIDI) Page ...................................................... 52
MIN ...................................................................................... 53
Mini YGDAI (Yamaha General Digital Audio Interface) card
(Glossary) ............................................................................... 74
Misc Page ............................................................................... 51
Miscellaneous Setup (Misc) Page ........................................... 51
Mixer I/O .............................................................................. 55
[MONITOR] Button ............................................................ 17
Monitoring ............................................................................ 44
[MUTE] Button .................................................................... 17
Mute Indicator ....................................................................... 39
Mute Switching ..................................................................... 42
N
Name .....................................................................................48
Net Page .................................................................................48
[NETWORK] Connector ................................................19, 27
[NETWORK] Indicator .........................................................16
Network Settings (Net) Page ..................................................48
Numeric Parameter ................................................................40
O
ON/OFF Parameter ...............................................................42
options ...................................................................................56
Output Level Control .............................................................42
Output Level Indicator ...........................................................39
P
Page Scroll Bar ........................................................................39
Panel Lock ..............................................................................39
Panel Lock Boot .....................................................................50
Panel Lock Icon ......................................................................39
Panel Lock Target ...................................................................50
Parameter Change ..................................................................53
Parameter Edit display ............................................................40
Peak Hold (Level Meter display) .............................................46
Peak Hold (Spectrum display) ................................................45
[PEAK] Indicator ...................................................................17
Phantom Master Switch .........................................................55
Phantom Power (Glossary) .....................................................74
[PHONES] Jack .....................................................................17
[PHONES LEVEL] Control ..................................................17
[POWER] Switch ...................................................................17
preparation .............................................................................20
preset parameter (Glossary) .....................................................74
Probe Monitor Function ........................................................44
Program Change .....................................................................53
Appendix
[HOME] Button ................................................................... 17
[HOME] Button (ICP1) ........................................................ 57
Host ....................................................................................... 52
HPF ....................................................................................... 55
R
rear panel ................................................................................18
Remote (Misc Page) ................................................................51
REMOTE connection ............................................................34
[REMOTE] Connector ....................................................19, 34
Reset (GPI Page) ....................................................................53
Reset (Slot Page) .....................................................................52
RJ-45 (Glossary) .....................................................................75
router (Glossary) .....................................................................75
RS-232C (Glossary) ................................................................75
RS-422 (Glossary) ..................................................................75
S
sampling frequency (Glossary) ................................................75
scene .......................................................................................14
scene (Glossary) ......................................................................75
[SCENE] Button ....................................................................17
[SCENE] Button (ICP1) ........................................................57
Scene Information ..................................................................39
[SCENE NUMBER] Indicator ..............................................17
DME64N/24N Owner’s Manual
77
Index
Scene Recall ........................................................................... 43
Scene Store (Misc Page) ......................................................... 51
Scene Store (Operation) ......................................................... 43
security cover mounting ......................................................... 20
Security Setup (Lock) Page ..................................................... 50
[SIGNAL] Indicator .............................................................. 17
Slot Information (Slot) Page .................................................. 52
Slot Page ................................................................................ 52
SLOT1~4 .............................................................................. 51
SP (Double Speed) ................................................................. 52
specifications .......................................................................... 65
Spectrum display .................................................................... 45
status message ........................................................................ 61
STP (Shielded Twisted Pair) Cable (Glossary) ....................... 75
Switching Hub (Glossary) ...................................................... 75
T
TDIF (Tascam Digital Interface Format) (Glossary) .............. 75
troubleshooting ...................................................................... 63
U
Appendix
Unit No ................................................................................. 55
USB (Universal Serial Bus) (Glossary) .................................... 75
USB connection ..................................................................... 26
[USB] Connector ................................................................... 16
USB-MIDI driver .................................................................. 26
User Defined Lock ................................................................. 50
user-defined parameter ........................................................... 14
User-defined parameter (Edit) ................................................ 42
User-defined Parameter Names .............................................. 39
Utility (Lock Page) ................................................................. 50
[UTILITY] Button ................................................................ 17
Utility display ........................................................................ 47
Utility display (Operation) ..................................................... 48
UTP (Unshielded Twisted pair) Cable (Glossary) .................. 75
V
Version .................................................................................. 48
W
WCIN ................................................................................... 51
WCLK (HA Page) ................................................................. 54
WCLK Page ........................................................................... 51
word clock ............................................................................. 24
Word Clock (Glossary) .......................................................... 75
WORD CLOCK connection ................................................. 33
[WORD CLOCK IN] [WORD CLOCK OUT] Connectors
......................................................................................... 19, 33
word clock master .................................................................. 33
Word Clock Setup (WCLK) Page .......................................... 51
word clock slave ..................................................................... 33
78
DME64N/24N Owner’s Manual
Z
zone ........................................................................................13
Zone (Net Page) .....................................................................48
zone control ............................................................................24
zone master .............................................................................13
zone slave ................................................................................13
For details of products, please contact your nearest Yamaha
representative or the authorized distributor listed below.
Pour plus de détails sur les produits, veuillez-vous adresser à Yamaha ou
au distributeur le plus proche de vous figurant dans la liste suivante.
NORTH AMERICA
CANADA
Yamaha Canada Music Ltd.
135 Milner Avenue, Scarborough, Ontario,
M1S 3R1, Canada
Tel: 416-298-1311
Die Einzelheiten zu Produkten sind bei Ihrer unten aufgeführten
Niederlassung und bei Yamaha Vertragshändlern in den jeweiligen
Bestimmungsländern erhältlich.
Para detalles sobre productos, contacte su tienda Yamaha más cercana
o el distribuidor autorizado que se lista debajo.
Yamaha Music Central Europe GmbH,
Branch Belgium
Rue de Geneve (Genevastraat) 10, 1140 - Brussels,
Belgium
Tel: 02-726 6032
FRANCE
U.S.A.
Yamaha Corporation of America
6600 Orangethorpe Ave., Buena Park, Calif. 90620,
U.S.A.
Tel: 714-522-9011
CENTRAL & SOUTH AMERICA
MEXICO
Yamaha de México S.A. de C.V.
Calz. Javier Rojo Gómez #1149,
Col. Guadalupe del Moral
C.P. 09300, México, D.F., México
Tel: 55-5804-0600
BRAZIL
Yamaha Musical do Brasil Ltda.
Av. Reboucas 2636-Pinheiros CEP: 05402-400
Sao Paulo-SP. Brasil
Tel: 011-3085-1377
ARGENTINA
Yamaha Music Latin America, S.A.
Sucursal de Argentina
Viamonte 1145 Piso2-B 1053,
Buenos Aires, Argentina
Tel: 1-4371-7021
PANAMA AND OTHER LATIN
AMERICAN COUNTRIES/
CARIBBEAN COUNTRIES
Yamaha Music Latin America, S.A.
Torre Banco General, Piso 7, Urbanización Marbella,
Calle 47 y Aquilino de la Guardia,
Ciudad de Panamá, Panamá
Tel: +507-269-5311
EUROPE
THE UNITED KINGDOM
Yamaha-Kemble Music (U.K.) Ltd.
Sherbourne Drive, Tilbrook, Milton Keynes,
MK7 8BL, England
Tel: 01908-366700
GERMANY
Yamaha Music Central Europe GmbH
Siemensstraße 22-34, 25462 Rellingen, Germany
Tel: 04101-3030
SWITZERLAND/LIECHTENSTEIN
Yamaha Music Central Europe GmbH,
Branch Switzerland
Seefeldstrasse 94, 8008 Zürich, Switzerland
Tel: 01-383 3990
AUSTRIA
Yamaha Music Central Europe GmbH,
Branch Austria
Schleiergasse 20, A-1100 Wien, Austria
Tel: 01-60203900
ASIA
BELGIUM/LUXEMBOURG
Yamaha Musique France
BP 70-77312 Marne-la-Vallée Cedex 2, France
Tel: 01-64-61-4000
ITALY
Yamaha Musica Italia S.P.A.
Combo Division
Viale Italia 88, 20020 Lainate (Milano), Italy
Tel: 02-935-771
SPAIN/PORTUGAL
Yamaha-Hazen Música, S.A.
Ctra. de la Coruna km. 17, 200, 28230
Las Rozas (Madrid), Spain
Tel: 91-639-8888
SWEDEN
Yamaha Scandinavia AB
J. A. Wettergrens Gata 1
Box 30053
S-400 43 Göteborg, Sweden
Tel: 031 89 34 00
INDONESIA
PT. Yamaha Music Indonesia (Distributor)
PT. Nusantik
Gedung Yamaha Music Center, Jalan Jend. Gatot
Subroto Kav. 4, Jakarta 12930, Indonesia
Tel: 21-520-2577
KOREA
Yamaha Music Korea Ltd.
Tong-Yang Securities Bldg. 16F 23-8 Yoido-dong,
Youngdungpo-ku, Seoul, Korea
Tel: 02-3770-0660
MALAYSIA
Yamaha Music Malaysia, Sdn., Bhd.
Lot 8, Jalan Perbandaran, 47301 Kelana Jaya,
Petaling Jaya, Selangor, Malaysia
Tel: 3-78030900
Yamaha Music Asia Pte., Ltd.
#03-11 A-Z Building
140 Paya Lebor Road, Singapore 409015
Tel: 747-4374
YS Copenhagen Liaison Office
Generatorvej 6A
DK-2730 Herlev, Denmark
Tel: 44 92 49 00
NORWAY
Norsk filial av Yamaha Scandinavia AB
Grini Næringspark 1
N-1345 Østerås, Norway
Tel: 67 16 77 70
OTHER EUROPEAN COUNTRIES
Yamaha Music Central Europe GmbH
Siemensstraße 22-34, 25462 Rellingen, Germany
Tel: +49-4101-3030
AFRICA
Yamaha Corporation,
Asia-Pacific Music Marketing Group
Nakazawa-cho 10-1, Hamamatsu, Japan 430-8650
Tel: +81-53-460-2313
MIDDLE EAST
TURKEY/CYPRUS
Yamaha Music Central Europe GmbH
Siemensstraße 22-34, 25462 Rellingen, Germany
Tel: 04101-3030
Yamaha Music Gulf FZE
LB21-128 Jebel Ali Freezone
P.O.Box 17328, Dubai, U.A.E.
Tel: +971-4-881-5868
Yamaha Music & Electronics (China) Co.,Ltd.
25/F., United Plaza, 1468 Nanjing Road (West),
Jingan, Shanghai, China
Tel: 021-6247-2211
SINGAPORE
DENMARK
OTHER COUNTRIES
THE PEOPLE’S REPUBLIC OF CHINA
TAIWAN
Yamaha KHS Music Co., Ltd.
3F, #6, Sec.2, Nan Jing E. Rd. Taipei.
Taiwan 104, R.O.C.
Tel: 02-2511-8688
THAILAND
Siam Music Yamaha Co., Ltd.
891/1 Siam Motors Building, 15-16 floor
Rama 1 road, Wangmai, Pathumwan
Bangkok 10330, Thailand
Tel: 02-215-2626
OTHER ASIAN COUNTRIES
Yamaha Corporation,
Asia-Pacific Music Marketing Group
Nakazawa-cho 10-1, Hamamatsu, Japan 430-8650
Tel: +81-53-460-2317
OCEANIA
AUSTRALIA
Yamaha Music Australia Pty. Ltd.
Level 1, 99 Queensbridge Street, Southbank,
Victoria 3006, Australia
Tel: 3-9693-5111
COUNTRIES AND TRUST
TERRITORIES IN PACIFIC OCEAN
Yamaha Corporation,
Asia-Pacific Music Marketing Group
Nakazawa-cho 10-1, Hamamatsu, Japan 430-8650
Tel: +81-53-460-2313
THE NETHERLANDS
Yamaha Music Central Europe,
Branch Nederland
Clarissenhof 5-b, 4133 AB Vianen, The Netherlands
Tel: 0347-358 040
HEAD OFFICE Yamaha Corporation, Pro Audio & Digital Musical Instrument Division
Nakazawa-cho 10-1, Hamamatsu, Japan 430-8650
Tel: +81-53-460-2441
PA11
Yamaha Manual Library
http://www2.yamaha.co.jp/manual/english/
This document is printed on chlorine free (ECF) paper with soy ink.
U.R.G., Pro Audio & Digital Musical Instrument Division, Yamaha Corporation
© 2004 Yamaha Corporation
WC32570 406MWCP22.2-01A0
Printed in Japan