OJ Electronics ETO2-EU Handleiding

Type
Handleiding
Type ETO2
Controller for ice and snow melting
67222A 04/14 (JRK)
© 2014 OJ Electronics A/S
• English
• Deutsch
• Polski
• Norsk
• Français
• Italiano
• Nederlands
GREEN COMFORT
Maximum comfort with low energy consumption
© 2014 OJ Electronics A/S
2
Type ETO2
INSTRUCTIONS
English ..................................................................................................................................... 3 - 7
Deutsch ................................................................................................................................... 8 - 13
Polski ...................................................................................................................................... 14 - 19
Norsk ....................................................................................................................................... 20 - 24
Français .................................................................................................................................. 25 - 30
Italiano ..................................................................................................................................... 31 - 36
Nederlands ............................................................................................................................ 37 - 42
USER MANUALS
English ..................................................................................................................................... 43 - 50
Deutsch ................................................................................................................................... 51 - 59
Polski ...................................................................................................................................... 60 - 68
Norsk ....................................................................................................................................... 69 - 76
Français .................................................................................................................................. 77 - 85
Italiano ..................................................................................................................................... 86 - 94
Nederlands ............................................................................................................................ 95 - 103
MENU OVERVIEW:
Menu overview ........................................................................................................................ 104
ILLUSTRATIONS
Illustrations .............................................................................................................................. 105 - 110
© 2014 OJ Electronics A/S
37
Nederlands
Instructie
ETO2 is een elektronische controller waarmee u
volledig automatisch en op energiezuinige wijze
ijs en sneeuw op buitenoppervlakken en in goten
kunt smelten.
IJsvorming is het gevolg van een lage tempera-
tuur in combinatie met vocht. ETO2 neemt zowel
de temperatuur als het vocht waar. Het sys-
teem voor het smelten van ijs en sneeuw wordt
gewoonlijk alleen geactiveerd wanneer er ijs of
sneeuw aanwezig is. ETO2 is geschikt voor zowel
elektrische verwarmingskabels als voor leidingen
van hydronische verwarming.
Productprogramma
ETO2-4550 Thermostaat.
ETOG-55 Grondsensoren voor het
waarnemen van temperatuur
en vocht.
ETOG-56/ETOK-1 Ingebouwde grondsensor
voor het waarnemen van
temperatuur en vocht.
ETOR-55 Gootsensor voor het waarne
-
men van vocht.
ETF-744/99 Buitensensor voor het waar
-
nemen van temperatuur.
ETF-522 Waterleidingsensor voor het
waarnemen van temperatuur.
WAARSCHUWING! – Lees deze hand-
leiding door!
Lees deze instructiehandleiding zorgvuldig door
en let goed op de onderstaande waarschuwin-
gen. Zorg dat u de toepassingsmogelijkheden,
weergaven en beperkingen van de controller vol-
ledig begrijpt. Wanneer u de instructies in deze
instructiehandleiding niet naleeft en daardoor een
verkeerde beslissing neemt, kunnen er fouten
optreden die kunnen resulteren in ijs en sneeuw
dat zodanig van aard is dat ernstig letsel of zelfs
de dood veroorzaakt kan worden.
WAARSCHUWING! – N.B.: sneeuw, ijs
en ijskegels kunnen ook nog aanwezig
zijn wanneer u de instructies uit deze handlei-
ding hebt opgevolgd.
We raden u aan om onverwachte vorming van
sneeuw, ijs of ijskegels in de gaten te houden.
U dient als extra veiligheidsmaatregel altijd een
handmatige inspectie van de openbare gebieden
uit te voeren teneinde veilige toegang tot de
bewuste gebieden te garanderen.
WAARSCHUWING! – Belangrijke veilig-
heidsaanwijzingen.
Schakel de voeding uit voordat er installatie- of
onderhoudswerkzaamheden op deze regelaar en
bijbehorende componenten worden uitgevoerd.
Deze regelaar en bijbehorende componenten
moeten door een vakbekwaam persoon worden
uitgevoerd (d.w.z. een erkend elektricien). De
elektrische installatie moet in overeenstemming
zijn met de geldende overheidsbepalingen.
NB! – De uitgangrelais zijn potentiaalvrij.
De monteur dient het geheel op een voe-
dingsbron, zoals een elektrisch panel, aan te slui-
ten.
CE-KEURMERK IN DE EU
OJ Electronics A/S verklaart hierbij dat het
product werd geproduceerd overeenkomstig
Richtlijn 2004/108/EG (en nadien volgende
wijzigingen) van de Raad inzake elektromagneti-
sche compatibiliteit en overeenkomstig Richtlijn
2006/95/EEG inzake elektrische apparatuur voor
toepassing bij bepaalde spanningslimieten.
© 2014 OJ Electronics A/S
38
Type ETO2
Toegepaste richtlijnen
ETO2-4550-EU28: CE-keurmerk LSR/EMC:
EN60730-2-9
ETO2-4550-US28: CAN/CSA E 60730-2-9:01.
ETO2-4550-RU28: CE-keurmerk LSR/EMC:
EN60730-2-9
Het product mag alleen worden gebruikt als de
gehele installatie voldoet aan de huidige richt-
lijnen.
Op dit product is garantie van de producent van
toepassing wanneer het product wordt geïnstal-
leerd overeenkomstig deze instructies en over-
eenkomstig actuele regelgeving.
Als het product op enigerlei wijze is beschadigd,
bijvoorbeeld tijdens transport, dan moet het
product door daartoe bevoegde medewerkers
worden gecontroleerd voordat het wordt aange-
sloten op de netspanning.
TECHNISCHE GEGEVENS
Thermostaat ETO2-4550:
Uitsluitend ontwikkeld voor bevestiging in
gebouwen!
Voedingsspanning ..........115/240 V wisselstroom
±10%, 50-60 Hz
Voedingsspanning voor
ETOG-/ETOR-verwarming
(SMPS) ............................. 28 V gelijkstroom, 8 VA
3 uitgangsrelais
(potentiaalvrij contact, NO) ......................3 X 16 A
Alarmrelais (potentiaalvrij contact, NO) ..max. 5 A
Regelsignaal voor
aandrijving (mengventiel) ....... 0-10 V gelijkstroom
Voedingsspanning voor
aandrijving (mengventiel) ..................... max. 48 V
wisselstroom/gelijkstroom/
max. 2 A
Aan/uitdierentieel ............................ 1,8 °F / 1 °C
Temperatuurbereik ............-4/+50 °F / -20/+10 °C
Omgevingstemperatuur .......32/122 °F / 0/+50 °C
Luchtvochtigheid omgeving .................... 10-95%
Kwaliteit behuizing ........................................IP 20
Gewicht ....................................................... 600 g
Afmetingen – HxBxD .....................90/156/45 mm
Type ..................................................................1B
Controle verontreinigingsgraad ..........................2
Nominale impulsspanning ............................. 4 kV
Grondsensor – type ETOG-55:
Ontwikkeld voor inbouw in buitenoppervlakken.
Detectie ..............................Vocht en temperatuur
Montage ............................... Buitenoppervlakken
Kwaliteit behuizing ........................................IP 68
Omgevingstemperatuur -57/+158 °F / -50/+70 °C
Afmetingen ....................................H32, Ø 60 mm
Grondsensor – ETOG-56/ETOK-1:
Ontwikkeld voor inbouw in buitenoppervlakken.
Detectie .............................Vocht en temperatuur
Montage .............................. Buitenoppervlakken
Kwaliteit behuizing ........................................IP 68
Omgevingstemperatuur -57/+158 °F /-50/+70 °C
Afmetingen, sensor ......................H32, Ø 60 mm
Afmetingen, buis .......................H78, Ø 63,5 mm
Gootsensor – type ETOR-55:
Ontwikkeld voor montage in een goot of leiding.
Wordt gebruikt in combinatie met een buitensen-
sor van het type ETF-744/99.
Detectie .......................................................Vocht
Montage ........................................Goot of leiding
Kwaliteit behuizing ........................................IP 68
Omgevingstemperatuur -57/+158 °F / -50/+70 °C
Afmetingen – HxBxD .....................105/30/13 mm
Buitensensor – EFT-744/99:
Detectie ............................................Temperatuur
Montage ......................................................Wand
Kwaliteit behuizing ........................................IP 54
Omgevingstemperatuur -57/+158 °F / -50/+70 °C
Afmetingen – HxBxD .......................86/45/35 mm
Waterleidingsensor – ETF-522:
Detectie ............................................Temperatuur
Montage ............................ Aan leiding gebonden
Kwaliteit behuizing ........................................IP 54
Omgevings-
temperatuur ................ -40/+248 °F / -40/+120 °C
Afmetingen .................................. Ø 6,5, L 50 mm
NB: Het smeltsysteem voor sneeuw en ijs
wordt gedeactiveerd wanneer er sprake
is van een storing in de sensor, ongeacht het
type sensor waarin de storing optreedt.
Nederlands / Instructie
© 2014 OJ Electronics A/S
39
Type ETO2
SENSOR INSTALLEREN
Grondsensor – ETOG, Afb. 1+3:
Voor installatie op buitenoppervlakken waar ijs
en sneeuw een terugkerend probleem vormen.
De sensor dient horizontaal ingebouwd te wor-
den. De bovenzijde dient gelijk te zijn aan het
omliggende oppervlak. De sensorkabel dient
geïnstalleerd te worden overeenkomstig actuele
regelgeving.
NB: We raden het gebruik van kabelleidingen
aan om de sensorkabel niet te beschadigen.
De sensor wordt geleverd met gedetailleerde
installatie-instructies.
Wanneer u de ETOG-55 aanbrengt, dient u de
bijgeleverde installatieplaat te gebruiken. Wanneer
u de ETOG-56 gebruikt, dient u de ETOK-1-mon-
tageset te gebruiken.
NB: Verwijder de installatieplaat van de
ETOG-55 voor u de eerste opstartproce-
dure uitvoert.
Gootsensor – ETOR, Afb. 2+4:
Voor installatie in een goot of afvoerpijp aan
de zonkant van het gebouw. U dient te zorgen
dat de contactelementen van de sensor in de
richting wijzen waarin het smeltwater stroomt. U
kunt zo nodig twee sensoren parallel installeren.
De sensor wordt geleverd met gedetailleerde
installatie-instructies.
N.B.: de roze en grijze draden worden
niet gebruikt.
Buitensensor – ETF-744/99, Afb. 2+4:
Hoewel ETF is ontworpen voor gebruik in com-
binatie met de gootsensor ETOR, kunt u ETF
ook los gebruiken om alleen de temperatuur te
laten meten. De sensor dient op de wand, onder
de dakrand aan de noordzijde van het gebouw
gemonteerd te worden.
Waterleidingsensor – ETF-522:
Deze wordt alleen gebruikt voor hydronische
verwarmingssystemen en is bedoeld om de
temperatuur van het toevoer- en retourwater te
meten. Dient rechtstreeks op de leiding beves-
tigd te worden met behulp van strippen.
Sensorkabels:
De ETOG- en ETOR-sensoren worden geleverd
met een kabel van 10 m. Een uitzondering
geldt voor de ETOG-56 die een kabel van 25 m
heeft. De kabels kunnen met behulp van een
standaard installatiekabel worden verlengd tot
ca. 200 m: 6 x 1,5 mm² voor ETOG en 4 x 1,5
mm² voor ETOR. De ETF-kabel kan met circa
50 m verlengd worden. De sensorkabels dienen
geïnstalleerd te worden overeenkomstig actuele
regelgeving. Ze mogen nooit parallel geïnstal-
leerd worden aan stroomkabels: de elektrische
storing kan tot verstoring van het sensorsignaal
leiden.
ETO2:
De eenheid dient op een DIN-rail en in een
goedgekeurd paneel gemonteerd te worden.
Wandmontage:
U kunt de bijbehorende plastic kap gebruiken
voor wandmontage in een binnenruimte.
Sluit de voedingsspanning aan op de aansluit-
punten N en L. Alle elektrische en mechanische
installatiewerkzaamheden dienen te worden
uitgevoerd overeenkomstig toepasselijke lokale
regels.
INSTALLATIE, ELEKTRISCHE VERWARMING
Regeling van elektrische verwarming met
1 zone, met ETOG (Afb. 3+6):
Sluit 1 of 2 ETOG-sensoren aan op de aan-
sluitpunten 11-20.
Sluit de verwarmingskabel aan op de relais
1, 2 en 3 van de potentiaalvrije uitgang. Volg
daarbij Afbeelding 8.
Regeling van elektrische verwarming met
1 zone, met ETOR + ETF (Afb. 4+7):
Sluit 1 of 2 ETOR-sensoren aan op de aan-
sluitpunten 11-20.
N.B.: de roze en grijze draden worden niet
gebruikt.
Sluit 1 ETF-sensor aan op de aansluitpunten
31-32.
Sluit de verwarmingskabel aan op de relais
1, 2 en 3 van de potentiaalvrije uitgang. Volg
daarbij Afbeelding 8.
Nederlands / Instructie
© 2014 OJ Electronics A/S
40
Type ETO2
CONFIGURATIE, HYDRONISCHE
VERWARMING
Regeling van hydronische verwarming met
1 zone voor het regelen van de tempera-
tuur van het toevoerwater d.m.v. mengven-
tiel (Afb. 6+11+13+16):
Sluit 1 of 2 ETOG-sensoren aan op de aan-
sluitpunten 11-20 Afbeelding 6.
Sluit de voedingsspanning (24 V, wissel-
stroom) voor het mengventiel aan op aansluit-
punten 25 en 26 (Afb. 13).
Sluit het mengventiel aan op de aansluitpunten
21-24 (Afb. 13).
Sluit de toevoer- en retoursensoren van ETF-
522 aan op de aansluitpunten 27-30 (afb. 16).
Sluit de primaire pomp aan op relais 1 van de
potentiaalvrije uitgang. Volg daarbij Afbeelding
14.
Sluit de secundaire pomp aan op relais 2 van
de potentiaalvrije uitgang. Volg daarbij Afbeel-
ding 14.
Eenvoudige regeling van hydronische ver-
warming met 1 of 2 zones (Afb. 3+6+12)
Sluit 1 of 2 ETOG-sensoren aan op de aan-
sluitpunten 11-20 Afbeelding 6.
Sluit de circulatiepomp voor zone 1 aan op
relais 1 van de potentiaalvrije uitgang. Volg
daarbij Afbeelding 14.
Sluit, wanneer zone 2 wordt gebruikt, de cir-
culatiepomp voor zone 2 aan op relais 2 van
de potentiaalvrije uitgang. Volg daarbij Afbeel-
ding 14.
Hanteer dezelfde installatie als voor de rege-
ling van elektrische verwarming met 1 of 2
zones; raadpleeg ‘Opstarten’ in de Gebrui-
kershandleiding.
AFSTANDSBEDIENING (Afb. 15):
De functies voor geforceerde verwarming en
stand-by kunnen op afstand worden bediend.
Verbindt daarvoor ETO2 met externe knop-
pen/relais (normaal open).
Verbindt de externe stand-by knop met de
aansluitpunten 33-34.
Verbindt de externe knop voor geforceerde
verwarming met de aansluitpunten 35-36.
Regeling van elektrische verwarming met
2 zones, met ETOG (Afb. 3+6):
Sluit 2 ETOG-sensoren aan op de aansluit-
punten 11-20.
Sluit de verwarmingskabel voor zone 1 aan
op relais 1 van de potentiaalvrije uitgang.
Volg daarbij Afbeelding 8.
Sluit de verwarmingskabel voor zone 2 aan
op relais 2 van de potentiaalvrije uitgang.
Volg daarbij Afbeelding 8.
Regeling van elektrische verwarming met
2 zones, met ETOR (Afb. 4+7):
Sluit 2 ETOR-sensoren aan op de aansluit-
punten 11-20.
N.B.: de roze en grijze draden worden niet
gebruikt.
Sluit de verwarmingskabel voor zone 1 aan
op relais 1 van de potentiaalvrije uitgang.
Volg daarbij Afbeelding 8.
Sluit de verwarmingskabel voor zone 2 aan
op relais 2 van de potentiaalvrije uitgang.
Volg daarbij Afbeelding 8.
Regeling van elektrische verwarming met
2 zones, met ETOG en ETOR (Afb. 5+6+7):
Sluit 1 ETOG-sensor als sensor 1 aan op de
aansluitpunten 11-16.
Sluit 1 ETOR-sensor als sensor 2 aan op
de aansluitpunten 17-20.
N.B.: de roze en
grijze draden worden niet gebruikt.
Sluit de
verwarmingskabel voor zone 1 (grond) aan
op relais 1 van de potentiaalvrije uitgang.
Volg daarbij Afbeelding 8. Sluit de verwar
-
mingskabel voor zone 2 (dak) aan op relais
2 van de potentiaalvrije uitgang. Volg daarbij
Afbeelding 8.
Regeling van elektrische verwarming met
1 zone, met uitgangsregeling (Y/) (Afb.
6+9+10):
Geavanceerde regeling met 2 fases, met
ETOG. 1/3 vermogen op verwarmingskabels
in naloop.
Sluit 1 of 2 ETOG-sensoren aan op de aan-
sluitpunten 11-20 Afbeelding 6.
Sluit de externe contactor/het externe relais
aan op relais 1, 2 en 3 van de potentiaalvrije
uitgang. Volg daarbij Afbeelding 10.
Nederlands / Instructie
© 2014 OJ Electronics A/S
41
Type ETO2
HET SMELTSYSTEEM TESTEN
We raden u aan om het smeltsysteem te testen
nadat u de installatie hebt afgerond en de toe-
passing hebt geconfigureerd.
1. Stel SET TEMP in het configuratiemenu in op
de maximumtemperatuur.
2. Giet wat water op de sensor (ETOG/ETOR).
3. De uitgangsrelais voor de verwarmingskabel
in de bewuste zone dient geactiveerd te
worden. Op het display van ETO2 dient ‘ON’
getoond te worden. Controleer of de verwar-
mingskabel warm wordt. Controleer indien
mogelijk ook de spanning.
4. Stel SET TEMP na het testen in op de
gewenste instelling (fabrieksinstelling = +3,0
°C/37,4 °F).
Nederlands / Instructie
BEDRADING (fig. 16)
AANSLUITPUNT KLEURCODE BEDRADING
N, L Voedingsspanning, 115-240 V wisselstroom, 50/60Hz
1, 2 Alarmrelais (potentiaalvrij), max. 5 A
3, 4 Uitgangsrelais 1, 16 A (potentiaalvrij),
Verwarmingskabel 1 (zone 1) /Primaire pomp
5, 6 Uitgangsrelais 2, 16 A (potentiaalvrij),
Verwarmingskabel 2 (zone 2) /Secundaire pomp
7, 8 Uitgangsrelais 3, 16 A (potentiaalvrij), Verwarmingskabel 3
11, 12 bruin/groen Sensorverwarming 1+2, ETOG 1+2 en ETOR 1+2
13, 14 grijs/roze Temperatuursensor, ETOG 1
15, 16 geel/wit Vochtsensor 1, ETOG 1/ETOR 1
17, 18 grijs/roze Temperatuursensor, ETOG 2
19, 20 geel/wit Vochtsensor 2, ETOG 2/ETOR 2
21, 22 3- of 4-wegs mengventiel, 0-10 V
23, 24 3- of 4-wegs mengventiel, 24 V wisselstroom
25, 26 24 V wisselstroom van externe voeding
voor 3- of 4-wegs mengventiel
27, 28 Temperatuursensor voor toevoerwater, ETF-522
29, 30 Temperatuursensor voor retourwater, ETF-522
31, 32 Buitentemperatuursensor, ETF
33, 34 Stand-by, externe ingang
35, 36 Geforceerde warmte, externe ingang
KABELS ETOR-SENSOR:
N.B.: de roze en grijze draden worden niet gebruikt.
Milieubescherming en recycling
Help het milieu te beschermen. Verwijder de
verpakking en overtollige producten op een ver-
antwoorde manier.
Verwijdering van het product.
Producten die zijn voorzien van dit
symbool mogen niet met het huishou-
delijk afval verwijderd worden. Lever
de producten in bij een inzamelings-
centrum en volg uw actuele, lokale regelgeving.
© 2014 OJ Electronics A/S
42
Type ETO2
Nederlands / Instructie
Afbeeldingen
Afb. 1 Installatie van ETOR-grondsensor
1 Sensor
2 Installatieplaat
3 Verwarmingselement
Afb. 2 Installatie van ETOR-gootsensor en ETF-
buitensensor
1 Thermostaat ETO2
2 Gootsensor
3 Buitensensor
Afb. 3 Elektrische verwarming met 1 zone, met
ETOG-sensor
Afb. 4 Elektrische verwarming met 1 zone, met
ETOR-/ETF-sensor
Afb. 5 Elektrische verwarming met 2 zones
(dak/grond)
Afb. 6 ETOG-aansluiting
Afb. 7 ETOR-aansluiting
Afb. 8 Aansluiting van verwarmingskabel, voor-
beeld
Afb. 9 Regeling voor elektrische verwarming
met 2 fases (Y/∆)
Afb. 10 Geavanceerde aansluiting met 2 fases
(Y/∆)
Afb. 11 Regeling van hydronische verwarming
met 1 zone voor het regelen van de
temperatuur van het toevoerwater d.m.v.
mengventiel
Afb. 12 Regeling van hydronische verwarming
met 1 of 2 zones, eenvoudig (zelfde
configuratie als regeling van elektrische
verwarming met 1 of 2 zones)
Afb. 13 Aansluiting voor hydronisch mengventiel
Afb. 14 Aansluiting voor hydronische pomp
Afb. 15 Aansluitingen voor afstandsbediening
voor stand-by en geforceerde verwar-
ming
Afb. 16 ETO2-controller, overzicht van aansluit-
punten
95
Nederlands
Gebruikershandleiding
INHOUDSOPGAVE
Woordenlijst .......................................... Pagina 95
Inleiding ............................................. Pagina 95
Opstarten ............................................ Pagina 96
Bediening ............................................ Pagina 97
Hoofdmenu ........................................... Pagina 97
Teksten op het display ..................................... Pagina 97
Informatie over de toepassing ................................ Pagina 98
Instellingen ........................................... Pagina 98
Opnieuw opstarten ....................................... Pagina 101
Het verschil kalibreren ..................................... Pagina 101
Fabrieksinstellingen ...................................... Pagina 101
Problemen oplossen ...................................... Pagina 102
WOORDENLIJST
Zone 1, 2: Onafhankelijke verwarmingszones waarin het ijs en de sneeuw gesmolten
kunnen worden.
Knop van encoder: U kunt aan deze knop draaien en op deze knop drukken om de instellingen
eenvoudig te configureren.
ETOG-55: Grondsensor voor het waarnemen van vocht en van de temperatuur.
ETOR-55: Gootsensor voor het waarnemen van vocht.
ETOG-56/ETOK-1: Ingebouwde grondsensor voor het waarnemen van vocht en van de
temperatuur.
ETF-744/99: Buitensensor voor het waarnemen van temperatuur.
Y/Δ: Geavanceerde bediening van elektrische verwarmingssystemen met 2 fasen.
Naloop: De warmte die het systeem gedurende een vastgestelde periode afgeeft nadat
het vocht-/temperatuursignaal is uitgeschakeld door een verwarmingscyclus.
INLEIDING
Type ETO2 is een elektronische controller waarmee u volledig automatisch en op energiezuinige wijze
ijs en sneeuw op buitenoppervlakken en in goten kunt smelten. IJsvorming is het gevolg van een
lage temperatuur in combinatie met vocht. ETO2 neemt zowel de temperatuur als het vochtgehalte
waar. Het verwarmingssysteem wordt allen geactiveerd wanneer beide parameters waarnemen dat er
mogelijk sprake is van ijs of sneeuw.
De eenvoudig te bedienen knop en het display met achtergrondverlichting maken snelle en eenvoudige
configuratie mogelijk. Ook geven ze eenvoudig de temperatuur, status, enz. weer.
© 2014 OJ Electronics A/S - ® Het OJ-handelsmerk is een gedeponeerd handelsmerk dat eigendom is van OJ Electronics A/S
© 2014 OJ Electronics A/S
96
Type ETO2
ETO2 kan elektrische verwarmingskabels in 1 of 2 zones aansturen. Het systeem beschikt ook over
geavanceerde uitgangsregeling met 2 fases, waardoor het op een energiezuinige wijze kan werken.
In de hydronische modus handhaaft de sensor de gewenste temperatuur voor het toevoerwater
wanneer het systeem actief is. Wanneer om hitte wordt gevraagd, worden de circulatiepomp en
hoofdpomp geactiveerd. Ook wordt het ventiel gedurende 1 minuut voor 20% geopend, zodat het
systeem kan stabiliseren.
Wanneer er geen ijs of sneeuw gesmolten hoeft te worden, activeert het systeem de circulatiepomp om
de 15 minuten 1 minuut om te controleren of de temperatuur van het retourwater gedaald is onder de
verplichte "stationairtemperatuur". Wanneer dat zo is, wordt het systeem helemaal geactiveerd, zodat
de temperatuur van het retourwater weer tot het gewenste niveau wordt teruggebracht.
OPSTARTEN
SELECT SCALE:
CELSIUS
FAHRENHEIT
Wanneer de ETO2 voor het eerst wordt opgestart, dient u aan te geven of u de
temperatuur in Celsius of in Fahrenheit wilt tonen. Draai aan de knop van de
encoder tot de gewenste temperatuurschaal wordt getoond. Bevestig vervolgens
uw keuze door de knop in te drukken.
SENSOR 1:
ETOG
ETOR
Op het display wordt SENSOR 1 getoond. U kunt nu de aangesloten sensor voor
ingang 1 selecteren:
ETOG : Grondsensor
ETOR : Gootsensor + buitensensor
Bevestig vervolgens uw keuze door de knop in te drukken.
SENSOR 2:
OFF
ETOG
ETOR
Op het display wordt vervolgens SENSOR 2 getoond. U kunt nu de aangesloten
sensor voor ingang 2 selecteren. Wanneer er geen sensor is aangesloten op
ingang 2, dient u OFF te selecteren.
OUTDOOR SENSOR:
OFF
ETF
Wanneer er een ETF-buitensensor is aangesloten op de aansluitpunten 31-32,
dient u ETF te selecteren.
Selecteer OFF wanneer er geen ETF-sensor is aangesloten. Bevestig vervolgens
uw keuze door de knop in te drukken.
APPLICATION:
ELECTRIC 1-ZONE
ELECTRIC 2-ZONE
ELECTRIC 2-STAGE
HYDRONIC
Selecteer de toepassing door aan de knop te draaien en op OK te drukken.
ELECTRIC 1-ZONE: Regeling van elektrische verwarming met 1 zone. NB: wordt
ook gebruikt voor eenvoudige hydronische installaties. Afb. 12
ELECTRIC 2-ZONE: Regeling van elektrische verwarming met 2 zones. NB:
wordt ook gebruikt voor eenvoudige hydronische installaties. Afb. 12.
ELECTRIC 2-STAGE: Geavanceerde regeling van elektrische verwarming met 2
fases (Y/Δ) in 1 zone. Afb. 10
HYDRONIC: Regeling van hydronische verwarming met 1 zone, met regeling van
toevoerwater. Afb. 11
Nederlands / Gebruikershandleiding
© 2014 OJ Electronics A/S
97
Type ETO2
Selecteer de juiste optie en druk op OK. Het systeem is nu geconfigureerd en zal volledig
automatisch werken overeenkomstig het eerder geconfigureerde standaardprogramma. Raadpleeg
FABRIEKSINSTELLINGEN voor meer informatie. U kunt ook alternatieve instellingen invoeren.
Raadpleeg daarvoor INSTELLINGEN.
ZONE 1 HEAT OFF
ZONE 2 HEAT OFF
AFTERRUN 1 0.00
AFTERRUN 2 0.00
STANDBY OFF
De status en de gegevens van de naloop voor de zones 1 en 2 worden nu op het
display getoond.
BEDIENING
ETO2 is voorzien van een eenvoudig te bedienen knop op de encoder die u kunt draaien en indrukken.
Ook heeft ETO2 een display waarop u de huidige situatie kunt aflezen. Het display is voorzien van
achtergrondverlichting. Deze verlichting gaat branden wanneer u op de knop op de encoder drukt (OK).
De verlichting gaat automatisch uit na 30 seconden.
Druk op de knop op de encoder om het hoofdmenu op het display te tonen.
Draai aan de knop om door de opties te bladeren. Niet alle opties worden in één keer op het display
getoond. U kunt ze echter openen door aan de knop op de encoder te draaien.
Druk op OK om een geselecteerde optie te kiezen.
HOOFDMENU
ZONE 1 OFF
ZONE 2 OFF
SENSOR 1 ##.#°C
SENSOR 2 ##.#°C
MOIST 1 NO
MOIST 2 NO
OUT. TEMP ##.#°C
SUPPLY W. ##.#°C
RETURN W. ##.#°C
ALARM NO
SHOW INFO
SETUP
RESTART
EXIT
TEKSTEN OP HET DISPLAY
ZONE 1 OFF
Verwarmingszone 1 actief (ON) of inactief (OFF)
ZONE 2 OFF
Verwarmingszone 2 actief (ON) of inactief (OFF)
SENSOR 1 ##.#°C
Kerntemperatuur van sensor 1 (verwarmde sensor). Alleen van toepassing
wanneer er een ETOG-sensor is aangesloten.
NB: De getoonde temperatuur is niet gelijk aan de omgevingstemperatuur
tijdens het vaststellen van het vochtgehalte!
Nederlands / Gebruikershandleiding
© 2014 OJ Electronics A/S
98
Type ETO2
SENSOR 2 ##.#°C
Kerntemperatuur van sensor 2 (verwarmde sensor). Alleen van toepassing
wanneer er een ETOG-sensor is aangesloten.
NB: De getoonde temperatuur is niet gelijk aan de omgevingstemperatuur tijdens
het vaststellen van het vochtgehalte!
MOIST 1 NO
Vochtstatus van sensor 1. YES / NO / Blank. 'Blank' wordt getoond wanneer de
temperatuur hoger is dan de waarde van 'Set Temp' of wanneer het systeem in
de naloopmodus actief is.
MOIST 2 NO
Vochtstatus van sensor 2. YES / NO / Blank. 'Blank' wordt getoond wanneer de
temperatuur hoger is dan de waarde van 'Set Temp' of wanneer het systeem in
de naloopmodus actief is.
OUT TEMP ##.#°C
Omgevingstemperatuur buiten. Alleen van toepassing wanneer er een ETF-
sensor is aangesloten.
SUPPLY W. ##.#°C
Temperatuur van toevoerwater, alleen voor hydronische toepassingen.
RETURN W. ##.#°C
Temperatuur van retourwater, alleen voor hydronische toepassingen.
ALARM NO
Storing; het type storing wordt getoond. Het rode led-lampje aan de voorzijde
van het apparaat knippert.
INFORMATIE OVER DE TOEPASSING
SHOW INFO
Soort toepassing: elektrische of hydronische verwarming
Softwareversie
Sensortype, sensor 1
Sensortype, sensor 2
Of er een ETF-sensor is aangesloten of niet
Terug naar het hoofdmenu
INSTELLINGEN
N.B.: onjuiste configuratie van het sensortype kan resulteren in slechte smelting van ijs en sneeuw.
Druk op OK. Op het display wordt een submenu getoond.
Selecteer de parameter die u wilt configureren en druk op OK.
APP: E. 1-ZONE
SW VERSION 1.00
SENSOR 1 ETOG
SENSOR 2 OFF
SENSOR ETF OFF
EXIT
Nederlands / Gebruikershandleiding
© 2014 OJ Electronics A/S
99
Type ETO2
SETUP
Geforceerde verwarming handmatig starten. Druk op OK en selecteer ON
om de geforceerde verwarming te starten.
De ETO2-controller zorgt gedurende de vooraf geprogrammeerde nalooptijd
voor warmte. Raadpleeg AFTERRUN 1 en 2.
Hier kunt u selecteren of de temperatuur getoond moet worden in Celsius
(C) of Fahrenheit (F). Selecteer de gewenste schaal en druk op OK. Druk op
OK om terug te keren naar het menu SETUP.
Stel de temperatuur in voor zone 1: Hier kunt u de temperatuur instellen
waarbij het smeltsysteem voor ijs en sneeuw geactiveerd wordt. U kunt de
temperatuur instellen binnen een bereik van +50/-20 °C (122/-4 °F). Stel de
gewenste temperatuur in en druk op OK.
Stel de temperatuur in voor zone 2: Hier kunt u de temperatuur instellen
waarbij het smeltsysteem voor ijs en sneeuw geactiveerd wordt. U kunt de
temperatuur instellen binnen een bereik van +50/-20 °C (122/-4 °F). Stel de
gewenste temperatuur in en druk op OK.
Hier kunt u de laagste bedrijfstemperatuur voor zone 1 instellen. Wanneer
de temperatuur onder deze temperatuur daalt, zal het systeem
overschakelen naar de stand-by-modus. U kunt kiezen voor een instelling
tot -20 °C (-3,9 °F). Ook kunt u OFF selecteren. OFF = geen limiet. Druk op
OK om de minimale inschakeltemperatuur te wijzigen. Draai vervolgens de
knop van de encoder naar de gewenste waarde en bevestig uw code door
op OK te drukken.
Hier kunt u de laagste bedrijfstemperatuur voor zone 2 instellen. U kunt
kiezen voor een instelling tot -20 °C (-3,9 °F). Ook kunt u OFF selecteren.
OFF = geen limiet. Druk op OK om de minimale inschakeltemperatuur te
wijzigen. Draai vervolgens de knop van de encoder naar de gewenste
waarde en bevestig uw code door op OK te drukken.
Nalooptijd zone 1: U kunt hier een nalooptijd van 0 tot 18 uur instellen. Het
systeem blijft gedurende de vastgestelde periode warmte afgeven nadat het
vocht-/temperatuursignaal is uitgeschakeld door een verwarmingscyclus.
Gebruik de knop op de encoder om de gewenste nalooptijd in te stellen en
druk vervolgens op OK.
Nalooptijd zone 2: U kunt hier een nalooptijd van 0 tot 18 uur instellen.
Gebruik de knop op de encoder om de gewenste nalooptijd in te stellen en
druk vervolgens op OK.
Hier kunt u de temperatuur voor zone 1 instellen. Wanneer u gebruik maakt
van de ETOG-55-sensor, is de temperatuur die op het ETO2-display wordt
getoond altijd de kerntemperatuur van de sensor. Raadpleeg HET
VERSCHIL KALIBREREN voor meer informatie.
FORCE HEAT OFF
SELECT SCALE C
SET TEMP 1 3.0C
SET TEMP 2 3.0C
OFF TEMP 1 OFF
OFF TEMP 2 OFF
AFTERRUN 1 2:00
AFTERRUN 2 2:00
OFFSET T1 0.0C
Nederlands / Gebruikershandleiding
© 2014 OJ Electronics A/S
100
Type ETO2
Hier kunt u de temperatuur voor zone 2 instellen. Wanneer u gebruik maakt
van de ETOG-55-sensor, is de temperatuur die op het ETO2-display wordt
getoond altijd de kerntemperatuur van de sensor. Raadpleeg HET
VERSCHIL KALIBREREN voor meer informatie.
Hier kunt u de buitentemperatuur instellen. De temperatuur die door de ETF-
buitensensor wordt gemeten, kan zo worden ingesteld dat de exacte
temperatuur op ETO2 wordt getoond. Meet de temperatuur naast de sensor
met behulp van een thermometer. Pas het verschil aan met behulp van de
knop op de encoder. Druk op OK.
Hier kunt u de minimumtemperatuur voor het retourwater instellen. Stel de
gewenste minimumtemperatuur in en druk op OK.
Deze menu-optie is alleen beschikbaar wanneer u gebruik maakt van
hydronische verwarming.
Hier kunt u de maximumtemperatuur voor het toevoerwater instellen. Stel
de gewenste maximumtemperatuur in en druk op OK.
Deze menu-optie is alleen beschikbaar wanneer u gebruik maakt van
hydronische verwarming.
In de automatische modus wordt de sensorverwarming uitgeschakeld
wanneer de smeltfunctie actief is. De sensor kan tijdens ongebruikelijke
omstandigheden of tijdens extreme kou voortdurend verwarmd worden.
Selecteer ON en druk op OK.
Hier kunt u de vochtregeling uitschakelen. Wanneer u dat doet, wordt het
smelten van sneeuw en ijs alleen geregeld op basis van de ingestelde
temperatuur. Raadpleeg SET TEMP voor meer informatie. Selecteer OFF om
de vochtregeling uit te schakelen. Druk vervolgens op OK.
N.B.: het energieverbruik en de daaraan verbonden kosten stijgen
wanneer de vochtregeling wordt uitgeschakeld.
U kunt de gevoeligheid van de sensor in 5 stappen aanpassen: MIN: bijv.
voor gestrooide wegen - LOW: bijv. voor vuile sneeuw - NORM: bijv. voor
gemengde sneeuw - HIGH: bijv. voor witte sneeuw - MAX: bijv. voor zeer
zuivere sneeuw of voor rijm. Druk op OK om de gevoeligheid te wijzigen.
Draai vervolgens de knop van de encoder naar de gewenste instelling en
bevestig uw code door op OK te drukken.
Informatie over de taal.
Hier kunt u alle fabrieksinstellingen voor ETO2 herstellen. Wanneer u deze
optie selecteert, worden alle aangepaste instellingen gewist.
Wanneer er sprake is van een configuratiefout in het menu STARTUP of
wanneer er nieuwe hardware wordt aangesloten, dient u de primaire
configuratie te wijzigen via het menu STARTUP. Selecteer PASSWORD en
OFFSET T2 0.0C
OFFSET OUT. 0.0C
MIN WATER 5.0C
MAX WATER 55.0C
SENSOR HEAT AUTO
MOIST CTRL ON
SENSITIVITY NORM
LANGUAGE ENGLISH
FACTORY RESET
REINSTALL
REINSTALL
PASSWORD XXXX
Nederlands / Gebruikershandleiding
© 2014 OJ Electronics A/S
101
Type ETO2
draai de knop van de encoder naar de fabriekscode (1202). De controller
keert terug naar het menu STARTUP. Raadpleeg OPSTARTEN voor meer
informatie.
Selecteer deze optie en druk op OK om terug te keren naar het hoofdmenu.
OPNIEUW OPSTARTEN
Wanneer u de instellingen wijzigt of wanneer het proces opnieuw gestart moet worden, kunt u de ETO2
opnieuw opstarten via het menu RESTART.
RESTART
Het systeem wordt dan opnieuw opgestart. Al uw huidige instellingen blijven
behouden. De ETO2 schakelt over naar het oorspronkelijke statusdisplay.
HET VERSCHIL KALIBREREN
Volg de onderstaande stappen wanneer u de door de ETOG-sensor gemeten temperatuur moet
aanpassen.
1. Koppel de sensor los van de aansluitpunten 11 en 12 (sensorverwarming) van de ETO2.
2. Wacht een paar uur tot de sensor de temperatuur van de grond heeft aangenomen.
3. Meet de echte temperatuur van de grond en van de sensor en vergelijk deze met de temperatuur
die op het display van de ETO2 wordt getoond.
4. Programmeer het verschil voor de bewuste sensor, zodat het verschil tussen de twee temperaturen
(de getoonde temperatuur en de daadwerkelijke temperatuur) wordt gecorrigeerd. Pas het verschil
aan met behulp van de knop op de encoder. Druk op OK.
5. Sluit de sensor weer aan op de aansluitpunten 11 en 12 (sensorverwarming) van de ETO2.
NB: Wanneer u gebruik maakt van de ETOG-sensor, is de temperatuur die op het ETO2-display wordt
getoond altijd de kerntemperatuur van de sensor.
FABRIEKSINSTELLINGEN
CONFIGURATIE FABRIEKSINSTELLINGEN EIGEN INSTELLINGEN
Toepassing Elektrisch
Sensor 1 ETOG
Sensor 2 OFF (UIT)
Kies een schaal Celsius
Nalooptijd Zone 1 2.00 uur
Nalooptijd Zone 2 2.00 uur
Temp.-compensatie Zone 1 0,0 °C / 0,0 °F
Temp.-compensatie Zone 2 0,0 °C / 0,0 °F
Temp.-compensatie ETF 0,0 °C / 0,0 °F
Instelpunt temperatuur Zones 1 en 2 3,0 °C / 37,4 °F
OFF-temperatuur Zones 1 en 2 OFF (UIT)
Sensorverwarming Zones 1 en 2 AUTO
EXIT
Nederlands / Gebruikershandleiding
© 2014 OJ Electronics A/S
102
Type ETO2
Vochtregeling Zones 1 en 2 ON
Gevoeligheid Zones 1+2 NORM
Min. watertemperatuur 5 °C / 41 °F
Max. watertemperatuur 55 °C / 131 °F
PROBLEMEN OPLOSSEN
We raden u aan om de configuratie van de ETO2 te controleren wanneer er storingen in het
smeltsysteem voor ijs en sneeuw optreden. Open het menu door op de knop van de encoder te
drukken. Selecteer SHOW INFO om de instellingen voor de toepassing te tonen. Activeer REINSTALL
met behulp van de fabriekscode 1202 wanneer er sprake is van fouten in de configuratie.
Controleer of alle onderdelen goed zijn aangesloten en of de kabels in de klemmen bevestigd zijn.
Raadpleeg onze website voor antwoorden op veelgestelde vragen: www.ojelectronics.com / support /
FAQ – Snowmelting.
Het ijs/de sneeuw smelt niet
Toont het display HEAT ON in zone 1/2?
JA:
o Wacht 1 tot 2 uur.
o Controleer de sneeuw. Wanneer de onderlaag smelt, werkt het systeem naar behoren.
o Controleer de verwarmingskabels om te kijken of er sprake is van defecten of slechte of
onjuiste aansluitingen.
o Wellicht is het te koud om de sneeuw te laten smelten (onvoldoende vermogen/m2). De
verwarmingskabels of het hydronische verwarmingssysteem is dan te kleinschalig voor de
toepassing.
NEE:
o De temperatuur is hoger dan de waarde voor SET TEMP. Stel SET TEMP in op een hogere
temperatuur.
o De sneeuw rondom de grondsensor is gesmolten of de smeltsneeuw heeft de sensor
blootgelegd.
Verhoog de AFTERRUN-tijd of activeer FORCE HEAT.
o Er is een iglo rondom de sensor ontstaan. De grondsensor heeft een geïsoleerde holte onder
de sneeuw gesmolten.
Activeer FORCE HEAT of stel MOIST CTRL in op OFF.
o De temperatuur is lager dan de instelling voor OFF TEMP.
Afhankelijk van de warmteopbrengst kan het systeem een lagere temperatuurlimiet hebben
waarbij de sneeuw kan smelten.
Probeer de sneeuw te smelten door FORCE HEAT te activeren voor u de OFF TEMP wijzigt.
De verwarming sluit niet af nadat het ijs/de sneeuw is gesmolten
o De ingestelde waarde voor AFTERRUN is te hoog. Verlaag de AFTERRUN-tijd en druk in het
menu op RESTART.
o Vochtdetectie in de ETOG-/ETOR-sensor is uitgeschakeld. Stel MOIST CTRL in het menu in
op ON.
Nederlands / Gebruikershandleiding
© 2014 OJ Electronics A/S
103
Type ETO2
Wanneer de rode ALARM-knop knippert, is één van de volgende storingen opgetreden. Het relevante
bericht wordt in het menu ALARM getoond.
“RETURN TEMP LOW” - De temperatuur van het water in de retourleiding is te laag.
“SUPPLY TEMP HIGH” - De temperatuur van het water in de toevoerleiding is te hoog.
“RETURN SENSOR” - De retoursensor is defect.
“SUPPLY SENSOR” - De toevoersensor is defect.
“TEMP SENSOR 1” - Temperatuursensor 1 (grond of dak) is defect.
“TEMP SENSOR 2” - Temperatuursensor 2 (grond of dak) is defect.
“OUTDOOR SENSOR” - De buitensensor is defect.
“SENSOR HEATER” - Er is sprake van kortsluiting in het verwarmingselement in de grond of
op het dak.
“FROST PROTECT” - Antivriesbeveiliging actief vanwege lage retourtemperatuur
(alleen voor hydronische systemen).
Nederlands / Gebruikershandleiding

Documenttranscriptie

Type ETO2 © 2014 OJ Electronics A/S 67222A 04/14 (JRK) Controller for ice and snow melting • English • Deutsch • Polski • Norsk • Français • Italiano • Nederlands GREEN COMFORT Maximum comfort with low energy consumption Type ETO2 Instructions English...................................................................................................................................... 3 - 7 Deutsch.................................................................................................................................... 8 - 13 Polski ....................................................................................................................................... 14 - 19 Norsk........................................................................................................................................ 20 - 24 Français................................................................................................................................... 25 - 30 Italiano...................................................................................................................................... 31 - 36 Nederlands............................................................................................................................. 37 - 42 User Manuals English...................................................................................................................................... 43 - 50 Deutsch.................................................................................................................................... 51 - 59 Polski ....................................................................................................................................... 60 - 68 Norsk........................................................................................................................................ 69 - 76 Français................................................................................................................................... 77 - 85 Italiano...................................................................................................................................... 86 - 94 Nederlands............................................................................................................................. 95 - 1 03 Menu overview: Menu overview......................................................................................................................... 104 illustrations Illustrations............................................................................................................................... 105 - 110 2 © 2014 OJ Electronics A/S Nederlands Instructie ETO2 is een elektronische controller waarmee u volledig automatisch en op energiezuinige wijze ijs en sneeuw op buitenoppervlakken en in goten kunt smelten. IJsvorming is het gevolg van een lage temperatuur in combinatie met vocht. ETO2 neemt zowel de temperatuur als het vocht waar. Het systeem voor het smelten van ijs en sneeuw wordt gewoonlijk alleen geactiveerd wanneer er ijs of sneeuw aanwezig is. ETO2 is geschikt voor zowel elektrische verwarmingskabels als voor leidingen van hydronische verwarming. Productprogramma ETO2-4550 Thermostaat. ETOG-55 Grondsensoren voor het waarnemen van temperatuur en vocht. ETOG-56/ETOK-1 Ingebouwde grondsensor voor het waarnemen van temperatuur en vocht. ETOR-55 Gootsensor voor het waarnemen van vocht. ETF-744/99 Buitensensor voor het waarnemen van temperatuur. ETF-522 Waterleidingsensor voor het waarnemen van temperatuur. WAARSCHUWING! – Lees deze handleiding door! Lees deze instructiehandleiding zorgvuldig door en let goed op de onderstaande waarschuwingen. Zorg dat u de toepassingsmogelijkheden, weergaven en beperkingen van de controller volledig begrijpt. Wanneer u de instructies in deze instructiehandleiding niet naleeft en daardoor een verkeerde beslissing neemt, kunnen er fouten optreden die kunnen resulteren in ijs en sneeuw dat zodanig van aard is dat ernstig letsel of zelfs de dood veroorzaakt kan worden. WAARSCHUWING! – N.B.: sneeuw, ijs en ijskegels kunnen ook nog aanwezig zijn wanneer u de instructies uit deze handleiding hebt opgevolgd. We raden u aan om onverwachte vorming van sneeuw, ijs of ijskegels in de gaten te houden. U dient als extra veiligheidsmaatregel altijd een handmatige inspectie van de openbare gebieden uit te voeren teneinde veilige toegang tot de bewuste gebieden te garanderen. WAARSCHUWING! – Belangrijke veiligheidsaanwijzingen. Schakel de voeding uit voordat er installatie- of onderhoudswerkzaamheden op deze regelaar en bijbehorende componenten worden uitgevoerd. Deze regelaar en bijbehorende componenten moeten door een vakbekwaam persoon worden uitgevoerd (d.w.z. een erkend elektricien). De elektrische installatie moet in overeenstemming zijn met de geldende overheidsbepalingen.  NB! – De uitgangrelais zijn potentiaalvrij. De monteur dient het geheel op een voedingsbron, zoals een elektrisch panel, aan te sluiten. CE-keurmerk in de EU OJ Electronics A/S verklaart hierbij dat het product werd geproduceerd overeenkomstig Richtlijn 2004/108/EG (en nadien volgende wijzigingen) van de Raad inzake elektromagnetische compatibiliteit en overeenkomstig Richtlijn 2006/95/EEG inzake elektrische apparatuur voor toepassing bij bepaalde spanningslimieten. © 2014 OJ Electronics A/S 37 Nederlands / Instructie Type ETO2 Toegepaste richtlijnen ETO2-4550-EU28: CE-keurmerk LSR/EMC: EN60730-2-9 ETO2-4550-US28: CAN/CSA E 60730-2-9:01. ETO2-4550-RU28: CE-keurmerk LSR/EMC: EN60730-2-9 Het product mag alleen worden gebruikt als de gehele installatie voldoet aan de huidige richtlijnen. Op dit product is garantie van de producent van toepassing wanneer het product wordt geïnstalleerd overeenkomstig deze instructies en overeenkomstig actuele regelgeving. Als het product op enigerlei wijze is beschadigd, bijvoorbeeld tijdens transport, dan moet het product door daartoe bevoegde medewerkers worden gecontroleerd voordat het wordt aangesloten op de netspanning. Technische gegevens Thermostaat ETO2-4550: Uitsluitend ontwikkeld voor bevestiging in gebouwen! Voedingsspanning...........115/240 V wisselstroom ±10%, 50-60 Hz Voedingsspanning voor ETOG-/ETOR-verwarming (SMPS).............................. 28 V gelijkstroom, 8 VA 3 uitgangsrelais (potentiaalvrij contact, NO).......................3 X 16 A Alarmrelais (potentiaalvrij contact, NO)... max. 5 A Regelsignaal voor aandrijving (mengventiel)........ 0-10 V gelijkstroom Voedingsspanning voor aandrijving (mengventiel) ...................... max. 48 V wisselstroom/gelijkstroom/ max. 2 A Aan/uitdifferentieel............................. 1,8 °F / 1 °C Temperatuurbereik............. -4/+50 °F / -20/+10 °C Omgevingstemperatuur........ 32/122 °F / 0/+50 °C Luchtvochtigheid omgeving..................... 10-95% Kwaliteit behuizing......................................... IP 20 Gewicht........................................................ 600 g Afmetingen – HxBxD......................90/156/45 mm Type...................................................................1B Controle verontreinigingsgraad........................... 2 Nominale impulsspanning.............................. 4 kV 38 Grondsensor – type ETOG-55: Ontwikkeld voor inbouw in buitenoppervlakken. Detectie...............................Vocht en temperatuur Montage................................ Buitenoppervlakken Kwaliteit behuizing......................................... IP 68 Omgevingstemperatuur.-57/+158 °F / -50/+70 °C Afmetingen.....................................H32, Ø 60 mm Grondsensor – ETOG-56/ETOK-1: Ontwikkeld voor inbouw in buitenoppervlakken. Detectie ..............................Vocht en temperatuur Montage ............................... Buitenoppervlakken Kwaliteit behuizing......................................... IP 68 Omgevingstemperatuur .-57/+158 °F /-50/+70 °C Afmetingen, sensor .......................H32, Ø 60 mm Afmetingen, buis ........................H78, Ø 63,5 mm Gootsensor – type ETOR-55: Ontwikkeld voor montage in een goot of leiding. Wordt gebruikt in combinatie met een buitensensor van het type ETF-744/99. Detectie........................................................ Vocht Montage.........................................Goot of leiding Kwaliteit behuizing......................................... IP 68 Omgevingstemperatuur.-57/+158 °F / -50/+70 °C Afmetingen – HxBxD......................105/30/13 mm Buitensensor – EFT-744/99: Detectie............................................. Temperatuur Montage.......................................................Wand Kwaliteit behuizing......................................... IP 54 Omgevingstemperatuur.-57/+158 °F / -50/+70 °C Afmetingen – HxBxD........................86/45/35 mm Waterleidingsensor – ETF-522: Detectie............................................. Temperatuur Montage............................. Aan leiding gebonden Kwaliteit behuizing......................................... IP 54 Omgevingstemperatuur................. -40/+248 °F / -40/+120 °C Afmetingen................................... Ø 6,5, L 50 mm NB: Het smeltsysteem voor sneeuw en ijs wordt gedeactiveerd wanneer er sprake is van een storing in de sensor, ongeacht het type sensor waarin de storing optreedt. © 2014 OJ Electronics A/S Nederlands / Instructie Type ETO2 Sensor installeren Grondsensor – ETOG, Afb. 1+3: Voor installatie op buitenoppervlakken waar ijs en sneeuw een terugkerend probleem vormen. De sensor dient horizontaal ingebouwd te worden. De bovenzijde dient gelijk te zijn aan het omliggende oppervlak. De sensorkabel dient geïnstalleerd te worden overeenkomstig actuele regelgeving. NB: We raden het gebruik van kabelleidingen aan om de sensorkabel niet te beschadigen. De sensor wordt geleverd met gedetailleerde installatie-instructies. Wanneer u de ETOG-55 aanbrengt, dient u de bijgeleverde installatieplaat te gebruiken. Wanneer u de ETOG-56 gebruikt, dient u de ETOK-1-montageset te gebruiken. NB: Verwijder de installatieplaat van de ETOG-55 voor u de eerste opstartprocedure uitvoert. Gootsensor – ETOR, Afb. 2+4: Voor installatie in een goot of afvoerpijp aan de zonkant van het gebouw. U dient te zorgen dat de contactelementen van de sensor in de richting wijzen waarin het smeltwater stroomt. U kunt zo nodig twee sensoren parallel installeren. De sensor wordt geleverd met gedetailleerde installatie-instructies. N.B.: de roze en grijze draden worden niet gebruikt. Buitensensor – ETF-744/99, Afb. 2+4: Hoewel ETF is ontworpen voor gebruik in combinatie met de gootsensor ETOR, kunt u ETF ook los gebruiken om alleen de temperatuur te laten meten. De sensor dient op de wand, onder de dakrand aan de noordzijde van het gebouw gemonteerd te worden. Waterleidingsensor – ETF-522: Deze wordt alleen gebruikt voor hydronische verwarmingssystemen en is bedoeld om de temperatuur van het toevoer- en retourwater te meten. Dient rechtstreeks op de leiding bevestigd te worden met behulp van strippen. Sensorkabels: De ETOG- en ETOR-sensoren worden geleverd met een kabel van 10 m. Een uitzondering geldt voor de ETOG-56 die een kabel van 25 m heeft. De kabels kunnen met behulp van een standaard installatiekabel worden verlengd tot ca. 200 m: 6 x 1,5 mm² voor ETOG en 4 x 1,5 mm² voor ETOR. De ETF-kabel kan met circa 50 m verlengd worden. De sensorkabels dienen geïnstalleerd te worden overeenkomstig actuele regelgeving. Ze mogen nooit parallel geïnstalleerd worden aan stroomkabels: de elektrische storing kan tot verstoring van het sensorsignaal leiden. ETO2: De eenheid dient op een DIN-rail en in een goedgekeurd paneel gemonteerd te worden. Wandmontage: U kunt de bijbehorende plastic kap gebruiken voor wandmontage in een binnenruimte. Sluit de voedingsspanning aan op de aansluitpunten N en L. Alle elektrische en mechanische installatiewerkzaamheden dienen te worden uitgevoerd overeenkomstig toepasselijke lokale regels. Installatie, elektrische verwarming • Regeling van elektrische verwarming met 1 zone, met ETOG (Afb. 3+6): Sluit 1 of 2 ETOG-sensoren aan op de aansluitpunten 11-20. Sluit de verwarmingskabel aan op de relais 1, 2 en 3 van de potentiaalvrije uitgang. Volg daarbij Afbeelding 8. • Regeling van elektrische verwarming met 1 zone, met ETOR + ETF (Afb. 4+7): Sluit 1 of 2 ETOR-sensoren aan op de aansluitpunten 11-20. N.B.: de roze en grijze draden worden niet gebruikt. Sluit 1 ETF-sensor aan op de aansluitpunten 31-32. Sluit de verwarmingskabel aan op de relais 1, 2 en 3 van de potentiaalvrije uitgang. Volg daarbij Afbeelding 8. © 2014 OJ Electronics A/S 39 Nederlands / Instructie Type ETO2 • Regeling van elektrische verwarming met 2 zones, met ETOG (Afb. 3+6): Sluit 2 ETOG-sensoren aan op de aansluitpunten 11-20. Sluit de verwarmingskabel voor zone 1 aan op relais 1 van de potentiaalvrije uitgang. Volg daarbij Afbeelding 8. Sluit de verwarmingskabel voor zone 2 aan op relais 2 van de potentiaalvrije uitgang. Volg daarbij Afbeelding 8. • Regeling van elektrische verwarming met 2 zones, met ETOR (Afb. 4+7): Sluit 2 ETOR-sensoren aan op de aansluitpunten 11-20. N.B.: de roze en grijze draden worden niet gebruikt. Sluit de verwarmingskabel voor zone 1 aan op relais 1 van de potentiaalvrije uitgang. Volg daarbij Afbeelding 8. Sluit de verwarmingskabel voor zone 2 aan op relais 2 van de potentiaalvrije uitgang. Volg daarbij Afbeelding 8. • Regeling van elektrische verwarming met 2 zones, met ETOG en ETOR (Afb. 5+6+7): Sluit 1 ETOG-sensor als sensor 1 aan op de aansluitpunten 11-16. Sluit 1 ETOR-sensor als sensor 2 aan op de aansluitpunten 17-20. N.B.: de roze en grijze draden worden niet gebruikt. Sluit de verwarmingskabel voor zone 1 (grond) aan op relais 1 van de potentiaalvrije uitgang. Volg daarbij Afbeelding 8. Sluit de verwarmingskabel voor zone 2 (dak) aan op relais 2 van de potentiaalvrije uitgang. Volg daarbij Afbeelding 8. • Regeling van elektrische verwarming met 1 zone, met uitgangsregeling (Y/∆) (Afb. 6+9+10): Geavanceerde regeling met 2 fases, met ETOG. 1/3 vermogen op verwarmingskabels in naloop. Sluit 1 of 2 ETOG-sensoren aan op de aansluitpunten 11-20 Afbeelding 6. Sluit de externe contactor/het externe relais aan op relais 1, 2 en 3 van de potentiaalvrije uitgang. Volg daarbij Afbeelding 10. 40 Configuratie, hydronische verwarming • Regeling van hydronische verwarming met 1 zone voor het regelen van de temperatuur van het toevoerwater d.m.v. mengventiel (Afb. 6+11+13+16): Sluit 1 of 2 ETOG-sensoren aan op de aansluitpunten 11-20 Afbeelding 6. Sluit de voedingsspanning (24 V, wisselstroom) voor het mengventiel aan op aansluitpunten 25 en 26 (Afb. 13). Sluit het mengventiel aan op de aansluitpunten 21-24 (Afb. 13). Sluit de toevoer- en retoursensoren van ETF522 aan op de aansluitpunten 27-30 (afb. 16). Sluit de primaire pomp aan op relais 1 van de potentiaalvrije uitgang. Volg daarbij Afbeelding 14. Sluit de secundaire pomp aan op relais 2 van de potentiaalvrije uitgang. Volg daarbij Afbeelding 14. • Eenvoudige regeling van hydronische verwarming met 1 of 2 zones (Afb. 3+6+12) Sluit 1 of 2 ETOG-sensoren aan op de aansluitpunten 11-20 Afbeelding 6. Sluit de circulatiepomp voor zone 1 aan op relais 1 van de potentiaalvrije uitgang. Volg daarbij Afbeelding 14. Sluit, wanneer zone 2 wordt gebruikt, de circulatiepomp voor zone 2 aan op relais 2 van de potentiaalvrije uitgang. Volg daarbij Afbeelding 14. Hanteer dezelfde installatie als voor de regeling van elektrische verwarming met 1 of 2 zones; raadpleeg ‘Opstarten’ in de Gebruikershandleiding. Afstandsbediening (Afb. 15): De functies voor geforceerde verwarming en stand-by kunnen op afstand worden bediend. Verbindt daarvoor ETO2 met externe knoppen/relais (normaal open). Verbindt de externe stand-by knop met de aansluitpunten 33-34. Verbindt de externe knop voor geforceerde verwarming met de aansluitpunten 35-36. © 2014 OJ Electronics A/S Nederlands / Instructie Type ETO2 Het smeltsysteem testen We raden u aan om het smeltsysteem te testen nadat u de installatie hebt afgerond en de toepassing hebt geconfigureerd. 1. Stel SET TEMP in het configuratiemenu in op de maximumtemperatuur. 2. Giet wat water op de sensor (ETOG/ETOR). 3. De uitgangsrelais voor de verwarmingskabel in de bewuste zone dient geactiveerd te worden. Op het display van ETO2 dient ‘ON’ getoond te worden. Controleer of de verwarmingskabel warm wordt. Controleer indien mogelijk ook de spanning. 4. Stel SET TEMP na het testen in op de gewenste instelling (fabrieksinstelling = +3,0 °C/37,4 °F). Milieubescherming en recycling Help het milieu te beschermen. Verwijder de verpakking en overtollige producten op een verantwoorde manier. Verwijdering van het product. Producten die zijn voorzien van dit symbool mogen niet met het huishoudelijk afval verwijderd worden. Lever de producten in bij een inzamelingscentrum en volg uw actuele, lokale regelgeving. Bedrading (fig. 16) Aansluitpunt Kleurcode Bedrading N, L Voedingsspanning, 115-240 V wisselstroom, 50/60 Hz 1, 2 Alarmrelais (potentiaalvrij), max. 5 A 3, 4 Uitgangsrelais 1, 16 A (potentiaalvrij), Verwarmingskabel 1 (zone 1) /Primaire pomp 5, 6 Uitgangsrelais 2, 16 A (potentiaalvrij), Verwarmingskabel 2 (zone 2) /Secundaire pomp 7, 8 Uitgangsrelais 3, 16 A (potentiaalvrij), Verwarmingskabel 3 11, 12 bruin/groen Sensorverwarming 1+2, ETOG 1+2 en ETOR 1+2 13, 14 grijs/roze Temperatuursensor, ETOG 1 15, 16 geel/wit Vochtsensor 1, ETOG 1/ETOR 1 17, 18 grijs/roze Temperatuursensor, ETOG 2 19, 20 geel/wit Vochtsensor 2, ETOG 2/ETOR 2 21, 22 3- of 4-wegs mengventiel, 0-10 V 23, 24 3- of 4-wegs mengventiel, 24 V wisselstroom 25, 26 24 V wisselstroom van externe voeding voor 3- of 4-wegs mengventiel 27, 28 Temperatuursensor voor toevoerwater, ETF-522 29, 30 Temperatuursensor voor retourwater, ETF-522 31, 32 Buitentemperatuursensor, ETF 33, 34 Stand-by, externe ingang 35, 36 Geforceerde warmte, externe ingang KABELS ETOR-SENSOR: N.B.: de roze en grijze draden worden niet gebruikt. © 2014 OJ Electronics A/S 41 Nederlands / Instructie Type ETO2 Afbeeldingen Afb. 1 Installatie van ETOR-grondsensor 1 Sensor 2 Installatieplaat 3 Verwarmingselement Afb. 2 Installatie van ETOR-gootsensor en ETFbuitensensor 1 Thermostaat ETO2 2 Gootsensor 3 Buitensensor Afb. 3 Elektrische verwarming met 1 zone, met ETOG-sensor Afb. 4 Elektrische verwarming met 1 zone, met ETOR-/ETF-sensor Afb. 5 Elektrische verwarming met 2 zones (dak/grond) Afb. 6 ETOG-aansluiting Afb. 7 ETOR-aansluiting Afb. 8 Aansluiting van verwarmingskabel, voorbeeld Afb. 9 Regeling voor elektrische verwarming met 2 fases (Y/∆) Afb. 10 Geavanceerde aansluiting met 2 fases (Y/∆) Afb. 11 Regeling van hydronische verwarming met 1 zone voor het regelen van de temperatuur van het toevoerwater d.m.v. mengventiel Afb. 12 Regeling van hydronische verwarming met 1 of 2 zones, eenvoudig (zelfde configuratie als regeling van elektrische verwarming met 1 of 2 zones) Afb. 13 Aansluiting voor hydronisch mengventiel Afb. 14 Aansluiting voor hydronische pomp Afb. 15 Aansluitingen voor afstandsbediening voor stand-by en geforceerde verwarming Afb. 16 ETO2-controller, overzicht van aansluitpunten 42 © 2014 OJ Electronics A/S Nederlands Gebruikershandleiding INHOUDSOPGAVE Woordenlijst. . . . . . . . . . . Inleiding. . . . . . . . . . . . . . Opstarten. . . . . . . . . . . . . Bediening. . . . . . . . . . . . . Hoofdmenu. . . . . . . . . . . . Teksten op het display. . . . . . Informatie over de toepassing . Instellingen. . . . . . . . . . . . Opnieuw opstarten.. . . . . . . Het verschil kalibreren. . . . . . Fabrieksinstellingen. . . . . . . Problemen oplossen. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pagina 95 Pagina 95 Pagina 96 Pagina 97 Pagina 97 Pagina 97 Pagina 98 Pagina 98 Pagina 101 Pagina 101 Pagina 101 Pagina 102 WOORDENLIJST Zone 1, 2: Onafhankelijke verwarmingszones waarin het ijs en de sneeuw gesmolten kunnen worden. Knop van encoder: U kunt aan deze knop draaien en op deze knop drukken om de instellingen eenvoudig te configureren. ETOG-55: Grondsensor voor het waarnemen van vocht en van de temperatuur. ETOR-55: Gootsensor voor het waarnemen van vocht. ETOG-56/ETOK-1: Ingebouwde grondsensor voor het waarnemen van vocht en van de temperatuur. ETF-744/99: Buitensensor voor het waarnemen van temperatuur. Y/Δ: Geavanceerde bediening van elektrische verwarmingssystemen met 2 fasen. Naloop: De warmte die het systeem gedurende een vastgestelde periode afgeeft nadat het vocht-/temperatuursignaal is uitgeschakeld door een verwarmingscyclus. INLEIDING Type ETO2 is een elektronische controller waarmee u volledig automatisch en op energiezuinige wijze ijs en sneeuw op buitenoppervlakken en in goten kunt smelten. IJsvorming is het gevolg van een lage temperatuur in combinatie met vocht. ETO2 neemt zowel de temperatuur als het vochtgehalte waar. Het verwarmingssysteem wordt allen geactiveerd wanneer beide parameters waarnemen dat er mogelijk sprake is van ijs of sneeuw. De eenvoudig te bedienen knop en het display met achtergrondverlichting maken snelle en eenvoudige configuratie mogelijk. Ook geven ze eenvoudig de temperatuur, status, enz. weer. © 2014 OJ Electronics A/S - ® Het OJ-handelsmerk is een gedeponeerd handelsmerk dat eigendom is van OJ Electronics A/S 95 Nederlands / Gebruikershandleiding Type ETO2 ETO2 kan elektrische verwarmingskabels in 1 of 2 zones aansturen. Het systeem beschikt ook over geavanceerde uitgangsregeling met 2 fases, waardoor het op een energiezuinige wijze kan werken. In de hydronische modus handhaaft de sensor de gewenste temperatuur voor het toevoerwater wanneer het systeem actief is. Wanneer om hitte wordt gevraagd, worden de circulatiepomp en hoofdpomp geactiveerd. Ook wordt het ventiel gedurende 1 minuut voor 20% geopend, zodat het systeem kan stabiliseren. Wanneer er geen ijs of sneeuw gesmolten hoeft te worden, activeert het systeem de circulatiepomp om de 15 minuten 1 minuut om te controleren of de temperatuur van het retourwater gedaald is onder de verplichte "stationairtemperatuur". Wanneer dat zo is, wordt het systeem helemaal geactiveerd, zodat de temperatuur van het retourwater weer tot het gewenste niveau wordt teruggebracht. OPSTARTEN SELECT SCALE: CELSIUS FAHRENHEIT SENSOR 1: ETOG ETOR SENSOR 2: OFF ETOG ETOR OUTDOOR SENSOR: OFF ETF APPLICATION: ELECTRIC 1-ZONE ELECTRIC 2-ZONE ELECTRIC 2-STAGE HYDRONIC 96 Wanneer de ETO2 voor het eerst wordt opgestart, dient u aan te geven of u de temperatuur in Celsius of in Fahrenheit wilt tonen. Draai aan de knop van de encoder tot de gewenste temperatuurschaal wordt getoond. Bevestig vervolgens uw keuze door de knop in te drukken. Op het display wordt SENSOR 1 getoond. U kunt nu de aangesloten sensor voor ingang 1 selecteren: ETOG : Grondsensor ETOR : Gootsensor + buitensensor Bevestig vervolgens uw keuze door de knop in te drukken. Op het display wordt vervolgens SENSOR 2 getoond. U kunt nu de aangesloten sensor voor ingang 2 selecteren. Wanneer er geen sensor is aangesloten op ingang 2, dient u OFF te selecteren. Wanneer er een ETF-buitensensor is aangesloten op de aansluitpunten 31-32, dient u ETF te selecteren. Selecteer OFF wanneer er geen ETF-sensor is aangesloten. Bevestig vervolgens uw keuze door de knop in te drukken. Selecteer de toepassing door aan de knop te draaien en op OK te drukken. ELECTRIC 1-ZONE: Regeling van elektrische verwarming met 1 zone. NB: wordt ook gebruikt voor eenvoudige hydronische installaties. Afb. 12 ELECTRIC 2-ZONE: Regeling van elektrische verwarming met 2 zones. NB: wordt ook gebruikt voor eenvoudige hydronische installaties. Afb. 12. ELECTRIC 2-STAGE: Geavanceerde regeling van elektrische verwarming met 2 fases (Y/Δ) in 1 zone. Afb. 10 HYDRONIC: Regeling van hydronische verwarming met 1 zone, met regeling van toevoerwater. Afb. 11 © 2014 OJ Electronics A/S Nederlands / Gebruikershandleiding Type ETO2 Selecteer de juiste optie en druk op OK. Het systeem is nu geconfigureerd en zal volledig automatisch werken overeenkomstig het eerder geconfigureerde standaardprogramma. Raadpleeg FABRIEKSINSTELLINGEN voor meer informatie. U kunt ook alternatieve instellingen invoeren. Raadpleeg daarvoor INSTELLINGEN. ZONE 1 HEAT OFF ZONE 2 HEAT OFF AFTERRUN 1 0.00 AFTERRUN 2 0.00 STANDBY OFF De status en de gegevens van de naloop voor de zones 1 en 2 worden nu op het display getoond. BEDIENING ETO2 is voorzien van een eenvoudig te bedienen knop op de encoder die u kunt draaien en indrukken. Ook heeft ETO2 een display waarop u de huidige situatie kunt aflezen. Het display is voorzien van achtergrondverlichting. Deze verlichting gaat branden wanneer u op de knop op de encoder drukt (OK). De verlichting gaat automatisch uit na 30 seconden. Druk op de knop op de encoder om het hoofdmenu op het display te tonen. Draai aan de knop om door de opties te bladeren. Niet alle opties worden in één keer op het display getoond. U kunt ze echter openen door aan de knop op de encoder te draaien. Druk op OK om een geselecteerde optie te kiezen. HOOFDMENU ZONE 1 OFF ZONE 2 OFF SENSOR 1 ##.#°C SENSOR 2 ##.#°C MOIST 1 NO MOIST 2 NO OUT. TEMP ##.#°C SUPPLY W. ##.#°C RETURN W. ##.#°C ALARM NO SHOW INFO SETUP RESTART EXIT TEKSTEN OP HET DISPLAY ZONE 1 OFF Verwarmingszone 1 actief (ON) of inactief (OFF) ZONE 2 OFF Verwarmingszone 2 actief (ON) of inactief (OFF) SENSOR 1 ##.#°C  erntemperatuur van sensor 1 (verwarmde sensor). Alleen van toepassing K wanneer er een ETOG-sensor is aangesloten. NB: De getoonde temperatuur is niet gelijk aan de omgevingstemperatuur tijdens het vaststellen van het vochtgehalte! © 2014 OJ Electronics A/S 97 Nederlands / Gebruikershandleiding SENSOR 2 Type ETO2 Kerntemperatuur van sensor 2 (verwarmde sensor). Alleen van toepassing wanneer er een ETOG-sensor is aangesloten. NB: De getoonde temperatuur is niet gelijk aan de omgevingstemperatuur tijdens het vaststellen van het vochtgehalte! ##.#°C MOIST 1 NO  Vochtstatus van sensor 1. YES / NO / Blank. 'Blank' wordt getoond wanneer de temperatuur hoger is dan de waarde van 'Set Temp' of wanneer het systeem in de naloopmodus actief is. MOIST 2 NO  Vochtstatus van sensor 2. YES / NO / Blank. 'Blank' wordt getoond wanneer de temperatuur hoger is dan de waarde van 'Set Temp' of wanneer het systeem in de naloopmodus actief is. OUT TEMP ##.#°C Omgevingstemperatuur buiten. Alleen van toepassing wanneer er een ETFsensor is aangesloten. SUPPLY W. ##.#°C Temperatuur van toevoerwater, alleen voor hydronische toepassingen. RETURN W. ##.#°C Temperatuur van retourwater, alleen voor hydronische toepassingen. Storing; het type storing wordt getoond. Het rode led-lampje aan de voorzijde van het apparaat knippert. ALARM NO INFORMATIE OVER DE TOEPASSING SHOW INFO APP: E. 1-ZONE SW VERSION 1.00 Soort toepassing: elektrische of hydronische verwarming Softwareversie SENSOR 1 ETOG Sensortype, sensor 1 SENSOR 2 OFF Sensortype, sensor 2 SENSOR ETF OFF Of er een ETF-sensor is aangesloten of niet EXIT Terug naar het hoofdmenu INSTELLINGEN N.B.: onjuiste configuratie van het sensortype kan resulteren in slechte smelting van ijs en sneeuw. Druk op OK. Op het display wordt een submenu getoond. Selecteer de parameter die u wilt configureren en druk op OK. 98 © 2014 OJ Electronics A/S Nederlands / Gebruikershandleiding Type ETO2 SETUP FORCE HEAT OFF Geforceerde verwarming handmatig starten. Druk op OK en selecteer ON om de geforceerde verwarming te starten. De ETO2-controller zorgt gedurende de vooraf geprogrammeerde nalooptijd voor warmte. Raadpleeg AFTERRUN 1 en 2. C  ier kunt u selecteren of de temperatuur getoond moet worden in Celsius H (C) of Fahrenheit (F). Selecteer de gewenste schaal en druk op OK. Druk op OK om terug te keren naar het menu SETUP. SET TEMP 1 3.0C Stel de temperatuur in voor zone 1: Hier kunt u de temperatuur instellen waarbij het smeltsysteem voor ijs en sneeuw geactiveerd wordt. U kunt de temperatuur instellen binnen een bereik van +50/-20 °C (122/-4 °F). Stel de gewenste temperatuur in en druk op OK. SET TEMP 2 3.0C Stel de temperatuur in voor zone 2: Hier kunt u de temperatuur instellen waarbij het smeltsysteem voor ijs en sneeuw geactiveerd wordt. U kunt de temperatuur instellen binnen een bereik van +50/-20 °C (122/-4 °F). Stel de gewenste temperatuur in en druk op OK. OFF TEMP 1 OFF Hier kunt u de laagste bedrijfstemperatuur voor zone 1 instellen. Wanneer de temperatuur onder deze temperatuur daalt, zal het systeem overschakelen naar de stand-by-modus. U kunt kiezen voor een instelling tot -20 °C (-3,9 °F). Ook kunt u OFF selecteren. OFF = geen limiet. Druk op OK om de minimale inschakeltemperatuur te wijzigen. Draai vervolgens de knop van de encoder naar de gewenste waarde en bevestig uw code door op OK te drukken. OFF TEMP 2 OFF Hier kunt u de laagste bedrijfstemperatuur voor zone 2 instellen. U kunt kiezen voor een instelling tot -20 °C (-3,9 °F). Ook kunt u OFF selecteren. OFF = geen limiet. Druk op OK om de minimale inschakeltemperatuur te wijzigen. Draai vervolgens de knop van de encoder naar de gewenste waarde en bevestig uw code door op OK te drukken. AFTERRUN 1 2:00 Nalooptijd zone 1: U kunt hier een nalooptijd van 0 tot 18 uur instellen. Het systeem blijft gedurende de vastgestelde periode warmte afgeven nadat het vocht-/temperatuursignaal is uitgeschakeld door een verwarmingscyclus. Gebruik de knop op de encoder om de gewenste nalooptijd in te stellen en druk vervolgens op OK. AFTERRUN 2 2:00 Nalooptijd zone 2: U kunt hier een nalooptijd van 0 tot 18 uur instellen. Gebruik de knop op de encoder om de gewenste nalooptijd in te stellen en druk vervolgens op OK. OFFSET T1 0.0C Hier kunt u de temperatuur voor zone 1 instellen. Wanneer u gebruik maakt van de ETOG-55-sensor, is de temperatuur die op het ETO2-display wordt getoond altijd de kerntemperatuur van de sensor. Raadpleeg HET VERSCHIL KALIBREREN voor meer informatie. SELECT SCALE © 2014 OJ Electronics A/S 99 Nederlands / Gebruikershandleiding Type ETO2 OFFSET T2 0.0C Hier kunt u de temperatuur voor zone 2 instellen. Wanneer u gebruik maakt van de ETOG-55-sensor, is de temperatuur die op het ETO2-display wordt getoond altijd de kerntemperatuur van de sensor. Raadpleeg HET VERSCHIL KALIBREREN voor meer informatie. OFFSET OUT. 0.0C Hier kunt u de buitentemperatuur instellen. De temperatuur die door de ETFbuitensensor wordt gemeten, kan zo worden ingesteld dat de exacte temperatuur op ETO2 wordt getoond. Meet de temperatuur naast de sensor met behulp van een thermometer. Pas het verschil aan met behulp van de knop op de encoder. Druk op OK. MIN WATER 5.0C MAX WATER 55.0C Hier kunt u de minimumtemperatuur voor het retourwater instellen. Stel de gewenste minimumtemperatuur in en druk op OK. Deze menu-optie is alleen beschikbaar wanneer u gebruik maakt van hydronische verwarming. Hier kunt u de maximumtemperatuur voor het toevoerwater instellen. Stel de gewenste maximumtemperatuur in en druk op OK. Deze menu-optie is alleen beschikbaar wanneer u gebruik maakt van hydronische verwarming. SENSOR HEAT AUTO In de automatische modus wordt de sensorverwarming uitgeschakeld wanneer de smeltfunctie actief is. De sensor kan tijdens ongebruikelijke omstandigheden of tijdens extreme kou voortdurend verwarmd worden. Selecteer ON en druk op OK. MOIST CTRL Hier kunt u de vochtregeling uitschakelen. Wanneer u dat doet, wordt het smelten van sneeuw en ijs alleen geregeld op basis van de ingestelde temperatuur. Raadpleeg SET TEMP voor meer informatie. Selecteer OFF om de vochtregeling uit te schakelen. Druk vervolgens op OK. ON  .B.: het energieverbruik en de daaraan verbonden kosten stijgen N wanneer de vochtregeling wordt uitgeschakeld. SENSITIVITY NORM U kunt de gevoeligheid van de sensor in 5 stappen aanpassen: MIN: bijv. voor gestrooide wegen - LOW: bijv. voor vuile sneeuw - NORM: bijv. voor gemengde sneeuw - HIGH: bijv. voor witte sneeuw - MAX: bijv. voor zeer zuivere sneeuw of voor rijm. Druk op OK om de gevoeligheid te wijzigen. Draai vervolgens de knop van de encoder naar de gewenste instelling en bevestig uw code door op OK te drukken. LANGUAGE Informatie over de taal. FACTORY RESET Hier kunt u alle fabrieksinstellingen voor ETO2 herstellen. Wanneer u deze optie selecteert, worden alle aangepaste instellingen gewist. REINSTALL Wanneer er sprake is van een configuratiefout in het menu STARTUP of wanneer er nieuwe hardware wordt aangesloten, dient u de primaire configuratie te wijzigen via het menu STARTUP. Selecteer PASSWORD en REINSTALL PASSWORD 100 ENGLISH XXXX © 2014 OJ Electronics A/S Nederlands / Gebruikershandleiding Type ETO2 draai de knop van de encoder naar de fabriekscode (1202). De controller keert terug naar het menu STARTUP. Raadpleeg OPSTARTEN voor meer informatie. Selecteer deze optie en druk op OK om terug te keren naar het hoofdmenu. EXIT OPNIEUW OPSTARTEN Wanneer u de instellingen wijzigt of wanneer het proces opnieuw gestart moet worden, kunt u de ETO2 opnieuw opstarten via het menu RESTART. RESTART Het systeem wordt dan opnieuw opgestart. Al uw huidige instellingen blijven behouden. De ETO2 schakelt over naar het oorspronkelijke statusdisplay. HET VERSCHIL KALIBREREN Volg de onderstaande stappen wanneer u de door de ETOG-sensor gemeten temperatuur moet aanpassen. 1. Koppel de sensor los van de aansluitpunten 11 en 12 (sensorverwarming) van de ETO2. 2. Wacht een paar uur tot de sensor de temperatuur van de grond heeft aangenomen. 3. Meet de echte temperatuur van de grond en van de sensor en vergelijk deze met de temperatuur die op het display van de ETO2 wordt getoond. 4. Programmeer het verschil voor de bewuste sensor, zodat het verschil tussen de twee temperaturen (de getoonde temperatuur en de daadwerkelijke temperatuur) wordt gecorrigeerd. Pas het verschil aan met behulp van de knop op de encoder. Druk op OK. 5. Sluit de sensor weer aan op de aansluitpunten 11 en 12 (sensorverwarming) van de ETO2. NB: Wanneer u gebruik maakt van de ETOG-sensor, is de temperatuur die op het ETO2-display wordt getoond altijd de kerntemperatuur van de sensor. FABRIEKSINSTELLINGEN CONFIGURATIE FABRIEKSINSTELLINGEN Toepassing Elektrisch ETOG Sensor 1 Sensor 2 OFF (UIT) Kies een schaal Celsius Nalooptijd Zone 1 2.00 uur Nalooptijd Zone 2 2.00 uur Temp.-compensatie Zone 1 0,0 °C / 0,0 °F Temp.-compensatie Zone 2 0,0 °C / 0,0 °F Temp.-compensatie ETF 0,0 °C / 0,0 °F Instelpunt temperatuur Zones 1 en 2 3,0 °C / 37,4 °F OFF-temperatuur Zones 1 en 2 OFF (UIT) Sensorverwarming Zones 1 en 2 AUTO © 2014 OJ Electronics A/S EIGEN INSTELLINGEN 101 Nederlands / Gebruikershandleiding Vochtregeling Zones 1 en 2 Gevoeligheid Zones 1+2 Min. watertemperatuur Max. watertemperatuur Type ETO2 ON NORM 5 °C 55 °C / 41 °F / 131 °F PROBLEMEN OPLOSSEN We raden u aan om de configuratie van de ETO2 te controleren wanneer er storingen in het smeltsysteem voor ijs en sneeuw optreden. Open het menu door op de knop van de encoder te drukken. Selecteer SHOW INFO om de instellingen voor de toepassing te tonen. Activeer REINSTALL met behulp van de fabriekscode 1202 wanneer er sprake is van fouten in de configuratie. Controleer of alle onderdelen goed zijn aangesloten en of de kabels in de klemmen bevestigd zijn. Raadpleeg onze website voor antwoorden op veelgestelde vragen: www.ojelectronics.com / support / FAQ – Snowmelting. Het ijs/de sneeuw smelt niet • Toont het display HEAT ON in zone 1/2? JA: o Wacht 1 tot 2 uur. o Controleer de sneeuw. Wanneer de onderlaag smelt, werkt het systeem naar behoren. o Controleer de verwarmingskabels om te kijken of er sprake is van defecten of slechte of onjuiste aansluitingen. o Wellicht is het te koud om de sneeuw te laten smelten (onvoldoende vermogen/m2). De verwarmingskabels of het hydronische verwarmingssysteem is dan te kleinschalig voor de toepassing. NEE: o De temperatuur is hoger dan de waarde voor SET TEMP. Stel SET TEMP in op een hogere temperatuur. o De sneeuw rondom de grondsensor is gesmolten of de smeltsneeuw heeft de sensor blootgelegd. Verhoog de AFTERRUN-tijd of activeer FORCE HEAT. o Er is een iglo rondom de sensor ontstaan. De grondsensor heeft een geïsoleerde holte onder de sneeuw gesmolten. Activeer FORCE HEAT of stel MOIST CTRL in op OFF. o De temperatuur is lager dan de instelling voor OFF TEMP. Afhankelijk van de warmteopbrengst kan het systeem een lagere temperatuurlimiet hebben waarbij de sneeuw kan smelten. Probeer de sneeuw te smelten door FORCE HEAT te activeren voor u de OFF TEMP wijzigt. De verwarming sluit niet af nadat het ijs/de sneeuw is gesmolten o De ingestelde waarde voor AFTERRUN is te hoog. Verlaag de AFTERRUN-tijd en druk in het menu op RESTART. o Vochtdetectie in de ETOG-/ETOR-sensor is uitgeschakeld. Stel MOIST CTRL in het menu in op ON. 102 © 2014 OJ Electronics A/S Nederlands / Gebruikershandleiding Type ETO2 Wanneer de rode ALARM-knop knippert, is één van de volgende storingen opgetreden. Het relevante bericht wordt in het menu ALARM getoond. “RETURN TEMP LOW” - De temperatuur van het water in de retourleiding is te laag. “SUPPLY TEMP HIGH” - De temperatuur van het water in de toevoerleiding is te hoog. “RETURN SENSOR” - De retoursensor is defect. “SUPPLY SENSOR” - De toevoersensor is defect. “TEMP SENSOR 1” - Temperatuursensor 1 (grond of dak) is defect. “TEMP SENSOR 2” - Temperatuursensor 2 (grond of dak) is defect. “OUTDOOR SENSOR” - De buitensensor is defect. “SENSOR HEATER” - Er is sprake van kortsluiting in het verwarmingselement in de grond of op het dak. “FROST PROTECT” - Antivriesbeveiliging actief vanwege lage retourtemperatuur (alleen voor hydronische systemen). © 2014 OJ Electronics A/S 103
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112

OJ Electronics ETO2-EU Handleiding

Type
Handleiding