APPLIED ENERGY FR22-30 Handleiding

Type
Handleiding

Deze handleiding is ook geschikt voor

FR22-30
FAN CONTROLLER
Installation and
Operating Instructions
A
NL
D
I
F
GB
GB
NL
D
A
F
I
GR
PLEASE NOTE:
THE CANADIAN (CSA) VERSION OF THIS FAN IS RATED AT 95W THIS IS FOR
CONNECTION TO TYPE B1 AND B2 FANS ONLY.
SEE "IDENTIFYING FAN TYPE" SECTION.
Low High
0I
45mm
210mm
86
m
m
86
m
m
208mm
Low Hi gh
0I
41mm
210mm
8
6m
m
8
1m
m
182mm
F1
F3
F4
F5
E
N
1
2
3
NF
3
2
1
L N E
L
N
11
14
13
12
F2
N
L3
2
1
L
N
13
11
12
E
N
NF
3
2
1
L
E
N
L
2
3
NF
E
N
2
1
L3
L
N
12
13
11
1
9
5
4
3
8
2
1
6
7
10
F6
14
14
L
N
A double pole isolating switch with a minimum contact
gap of 3mm (Wall or Ceiling mounted).
Suitably rated 5-core cable to connect the controller to
the fan. If the fan is window mounted, use flexible cable
(Available from Xpelair).
Suitably rated 3-core cable to connect the controller to
the Main Electrical Supply.
If using flexible cable, suitable glands
incorporating cable clamps must be fitted
to the knockouts in the Controller Box.
(Refer to Fig. 1).
These Instructions are for the Installation and Operation of the FR22/30 Fan Controller only. For Fan
Installation and Operating Instructions refer to literature provided with the appropriate fan.
Not where ambient temperatures are likely to exceed
50°C.
If installed in a kitchen the Controller must not be
mounted immediately above a cooker hood or eye
level grill.
When intended for use in possible chemical corrosive
atmospheres, consult our Technical Service
Department (Outside the UK contact your local Xpelair
distributor).
If installed in a shower room or bathroom the
controller and isolating switch must be situated so
that they cannot be touched by persons making use
of the bath or shower.
This appliance is designed to control the operation of Xpelair
fans of the GX9, GX12, WX9, WX12, RX9 & RX12 ranges
(wall & window mounted). The controller may be either surface
mounted, or recess mounted within it’s own patress box. You
may only wire one fan to each controller.
For the purpose of these instructions current and previous
versions of the fans are identified into Type A & Type B, as
follows:
If wiring to Type A fans
A link is fitted between terminals 2 and 3 in the fan socket,
this must be removed before connecting the Controller.
If you do not remove it, the Controller will be permanently
damaged.
If wiring to Type B fans
There is no wire link to be removed.
If the fan is already installed
1 Ensure the power supply is isolated.
2 Disconnect the mains connections from the fan’s
terminal socket or from the terminal block.
3 Remove the existing wiring and make it safe.
1 Route the 5-core cable from the Fan to the Controller
position.
2 Wire one end of the cable into the fan connections as
shown thus:
3 Leave the other end ready to be connected to the
Controller.
Type A1
Type A2
Type B1
Type B2
Location of the Controller
Wire the fan electrical connections
Description
What the installer will need
Identifying Fan Type
Preparing the Fan
General Information Working with the Fan
If the fan is not yet installed.
1 Check that the fan electrical rating matches the power
supply.
FAN TYPE
F1
F2
F3
DIAGRAM
Type A1
Type A2
Type B
Table 1.
If wiring to an existing installation
isolate mains supply and remove applicable
fuses prior to any electrical procedure.
FR22/30 Fan Controller Installation and
Operating Instructions
These installation instructions are for the installation of the
controller when used in combination with Xpelair supplied fans.
The controller must be installed to fixed
wiring. Ensure the Main Electrical Supply
matches the rating shown on the controller
casing.
This appliance must be earthed.
All installation must be supervised by a qualified electrician.
Installation and wiring must conform to current IEE wiring
regulations (UK), or local appropriate regulations (other
countries).
If you have any queries either before, during and after
the installation of the controller, please do not hesitate
to contact the UK Xpelair hotline (number on back page).
Customers outside the UK: contact your local Xpelair
distributor.
Installing the Controller
Remove the Cover and Mounting Frame
Eye protection must be worn during all
drilling & chiselling operations.
Check there are no buried Pipes or Cables
in the wall or obstructions on the outside
e.g. Electricity, Gas, Water.
Mounting the Wall Box
If surface mounting
1 Insert suitable glands into the knockouts.
2 Feed both cables through the glands.
3 Fix the Wall Box and Plastic Surround to the wall, using
the mounting holes provided.
4 Reconnect the earth lead to the Wall Box.
If recess mounting
1 Make a hole in the wall big enough to take the Wall Box.
Discard the Plastic Surround.
2 Insert suitable glands into the knockouts.
3 Feed both cables through these glands.
4 Fix the Wall Box to the wall. Ensure that the
flange of the mounting frame fits flush to the finished
surface of the wall (Refer diagram F6).
5 Reconnect the earth lead to the Wall Box.
Wire the Controller electrical connections
1 Mount the Isolation Switch in accordance with the
manufacturers instructions.
2 Wire the Controller to the Isolation Switch and to the Fan
as shown in the appropriate diagram (Refer to Table 1).
3 Refit Mounting Frame to Metal Wall Box.
4 Refit the Fascia to the Mounting Frame.
5 Refit the Screw Covers.
1 Ensure power supply is isolated and fuses are
removed.
2 Route the Cable from the Isolating Switch to the point of
connection to the power supply.
3 Make all connections within the Isolating Switch in
accordance with the manufacturers instructions.
4 Following all local regulations make connection at point of
power supply.
5 Make a final check to ensure all earth points are connected
and all covers have been correctly replaced on the fan,
controller and isolating switch.
6 Replace all fuses, and switch on the power supply.
For fixed wiring circuits the protective fuse for the
appliance must not exceed 5 amps.
For Australia only:
These models are permanently connected to the supply &
operation is controlled by a remote switch. They should be
directly wired to the supply through an approved 10 amp wall
mounted surface switch with at least 3mm clearance between
contacts.
Mounting the Controller
1 Detach the Fascia from the Mounting Frame by removing
the screw covers and two screws (Refer to Fig. 2a&b).
2 Detach the Mounting Frame from the Wall Box by
removing the two screws (Refer to Fig. 2c).
3 Lift the Wall Box away from the Plastic Surround.
4 Check that the electrical rating shown inside the controller
matches the power supply.
5 Disconnect the earth wire from the Wall Box.
6 Make cable entry holes in the plastic and metal boxes by
removing suitable knockouts (Refer to Fig. 1).
Connect to Power Supply
Fig. 1 : Cable Gland Positions
Fig. 2a : Removing screw covers Fig. 2b:Removing fascia Fig. 2c: Removing mounting frame
Cleaning
1 Before cleaning isolate the Controller completely
from the power supply.
2 Wipe the Cover carefully with a damp cloth.
3 Dry thoroughly.
4 Ensure ventilation slots are free from obstuctions at all
times.
Never immerse the Controller in water
or other liquids.
Never use solvents to clean the
Controller.
Apart from cleaning, no other
maintenance is required.
Looking after the Controller
Operating the Controller
Using your Controller
1 On / Off switch
2 Intake / Extract switch
3 High / Low speed
4 Indicator light
5 Ventilation slots
6 Screw cover
7 Fascia
8 Mounting Frame
9 Wall Box
10 Plastic Surround
11 Controllers Terminal Block
12 Fan’s Terminal Block
13 Double Pole Isolator switch
14 Fuses
The Controller has the following features: (Refer to diagrams
F1-F4).
Deze niet aanbrengen waar de omgevingstemperaturen
50CN te boven gaan.
Wanneer in een keuken aangebracht mag de regelaar
niet direct boven een wasemkap of ooghoogte van de
grill worden gemonteerd.
Wanneer bestemd voor gebruik in mogelijk chemisch
corrosieve atmosferen eerst onze Technische Service
afdeling raadplegen. (Buiten GB: neem contact op met
uw lokale Xpelair dealer).
Wanneer gemonteerd in een douche- of badkamer dan
moet de regelaar daar worden aangebracht waar zij
niet kunnen worden aangeraakt door personen die de
douche of het bad gebruiken.
Een tweepolige schakelaar met een minimum
contactafstand van 3 mm (muur- of plafondmontage).
Passende 5-aderige kabel om de regelaar aan de ventilator
aan te sluiten. Als de ventilator raam-gemonteerd wordt
dan moet een flexibele kabel worden gebruiken.
(Verkrijgbaar bij Xpelair).
Passende 3-aderige kabel voor de aansluiting van de
regelaar aan de hoofdstroomtoevoer.
Wanneer flexibele kabel wordt gebruikt
moeten passende doorvoeren worden
aangebracht via de uitbreekplaatjes in de doos
van de regelaar. (Zie Afb. 1.)
Deze voorschriften zijn uitsluitend bestemd voor de installatie en bediening van de FR22/30 ventilator-regeleenheid. Voor de
Installatie- en bedieningsvoorschriften van de ventilator gelieve u de met de betreffende ventilator meegeleverde literatuur te
raadplegen.
Dit apparaat is bedoeld om de bediening te besturen van de
Xpelair ventilatoren type GX9, GX12, WX9, WX12, RX9 &
RX12 (wand- of raammontage). De regelaar kan of op een
oppervlak worden gemonteerd, of in een uitsparing voor zijn
eigen gegalvaniseerd metalen inbouwdoos. U mag enkel één
ventilator aan elke regelaar aansluiten.
Ten behoeve van deze voorschriften worden de huidige en
vroegere versies ventilatoren geïdentificeerd als Type A &
Type B, zie hierna:
Bij aansluiting van Type A ventilatoren
In de contactdoos van de ventilator is tussen klem 2 en 3
een verbindingsdraad aangebracht die moet worden
verwijderd voordat de regelaar wordt aangesloten. Als u
de verbindingsdraad niet verwijderd zal dit permanente
beschadiging van de regelaar tot gevolg hebben.
Bij aansluiting van Type B ventilatoren
Hier hoeft geen verbindingsdraad te worden verwijderd.
Als de ventilator reeds is geinstalleerd
1. Zorg ervoor dat de netvoeding is geisoleerd.
2. Maak de elektrische aansluitingen los van de klembus
of van het klemmenblok van de ventilator.
3. Verwijder de bestaande bedrading en maak deze veilig.
Type A1
Type A2
Type B1
Type B2
Als de ventilator nog niet is geinstalleerd
1 Controleer of de toelaatbare nominale waarde van de
ventilator overeenkomt met de stroomtoevoer.
Wanneer de ventilator aan een bestaande
installatie wordt aangesloten moet eerst de
stroomtoevoer worden geisoleerd en van
toepassing zijnde zekeringen worden
verwijderd en wel voordat aan gelijk welke
elektrische procedure wordt begonnen.
Installatie- en bedieningsvoorschriften
voor de regeleenheid van de FR22/30 Ventilator
Deze installatievoorschriften zijn bestemd voor de installatie
van de besturingseenheid wanneer deze wordt gebruikt in
combinatie met door Xpelair geleverde ventilatoren.
Deze regelaar moet aan vaste bedrading
worden aangebracht. Zorg ervoor dat de
hoofdstroomtoevoer overeenkomt met
de toelaatbare nominale waarde als
afgebeeld op het huis van de regelaar.
Denk eraan, dit apparaat moet geaard
zijn.
Alle installatiewerkzaamheden moeten worden verricht onder
toezicht van een erkend elektricien.
Installatie en aansluiting moeten worden uitgevoerd conform
de huidige IEE reglementen (VK), of de lokaal van toepassing
zijnde reglementen (andere landen).
Wanneer u voor, tijdens of na de installatie van de regelaar
nog vragen mocht hebben, aarzel dan niet contact op te
nemen met de GB hotline (voor nummer zie laatste
bladzijde). Klanten buiten GB wordt aangeraden contact
op te nemen met hun plaatselijke Xpelair dealer.
Beschrijving
Algemene informatie
Installeren van de regeleenheid
Nodig voor de installatie
Aanbrengen van de regeleenheid
Preparatie van de ventilator
Werken met de ventilator
Identificeren van het type ventilator
Bedrading van de elektrische aansluitingen
van de ventilator
1. Breng de 5-aderige kabel aan van de ventilator naar de
regelaar.
2. Sluit één kant van de kabel aan in de aansluitingen van de
ventilator, als hierna afgebeeld:
3. Maak de nadere kant klaar om aan de regelaar te worden
aangesloten.
TYPE VENTILATOR
F1
F2
F3
SCHAKELSCHEMA
Type A1
Type A2
Type B
Tabel 1.
NL
Verwijdering van de afdekkap
en het montageframe
Bij alle boor- en beitelwerkzaamheden moet
oogbescherming worden gedragen.
Montage van de wanddoos
Bij oppervlakte-montage
1. Breng passende kabeldoorvoeren in de uitbreekplaatjes aan.
2. Voer beide kabels in door de doorvoeren.
3. Monteer de wanddoos en kunststof ombouw aan de muur via
de aangebrachte montagegaten.
4. Verbind de aardleiding weer aan de wanddoos.
Montage in een uitsparing
1. Maak een gat in de muur dat groot genoeg is voor de wanddoos.
Gooi de kunststof ombouw weg.
2. Breng passende kabeldoorvoeren in de uitbreekplaatjes aan.
3. Voer beide kabels in door de doorvoeren.
4. Monteer de wanddoos aan de muur. Zorg ervoor dat de flens
van het montageframe gelijk is met het afgewerkte oppervlak
van de muur. (Zie tekening F6.)
5. Verbind de aardleiding weer aan de wanddoos.
Aansluiting van de elektrische verbindingen
van de regeleenheid.
1. Monteer de scheidingsschakelaar conform de voorschriften van
de fabrikant.
2. Sluit de regeleenheid aan naar de scheidingsschakelaar en naar
de ventilator, als weergegeven in de betreffende tekening. (Zie
tabel 1.)
3. Bevestig het montageframe weer aan de metalen wanddoos.
4. Bevestig het bedieningspaneel weer aan het montageframe.
5. Breng de schroefdoppen weer aan.
1. Zorg ervoor dat de stroomtoevoer gescheiden is en de
zekeringen zijn verwijderd.
2. Breng de kabel aan van de scheidingsschakelaar naar het
aansluitpunt naar de stroomtoevoer.
3. Breng alle aansluitingen in de scheidingsschakelaar aan
conform de voorschriften van de fabrikant.
4. Volg alle lokaal geldende voorschriften op voor het maken van
een aansluiting bij het aansluitpunt voor de stroomtoevoer.
5. Voer een laatste controle uit om te verzekeren dat alle
aardpunten zijn aangesloten en alle afdekkappen weer correct
zijn aangebracht op de ventilator, regeleenheid en
scheidingsschakelaar.
6. Breng alle zekeringen weer aan en schakel de stroomtoevoer
aan.
Enkel voor Australië:
Aansluiting aan de stroomtoevoer kan worden gemaakt met
een flexibele 3-aderige kabel compleet met een 3-polige steker
voor invoer in een goedgekeurde 10 amp GPO, of kan direct
worden aangesloten via een goedgekeurde 10 amp muur-
gemonteerde oppervlakteschakelaar met (ten minste) 3 mm
afstand tussen de contacten.
Montage van de regeleenheid
Aansluiten aan de stroomtoevoer
Afb. 1: Plaatsen voor de drukringen
Afb. 2a: Verwijderen van schroefdoppen Afb. 2b: Verwijderen van bedieningspaneel Afb. 2c: Verwijderen van montageframe
Schoonmaken
1. Voorafgaand aan reiniging de stroomtoevoer naar de
regelaar geheel isoleren.
2. De afdekkap voorzichtig met een vochtige doek afnemen.
3. Goed afdrogen.
4. Houd de ventilatiegroeven vrij van obstructies.
De regelaar nooit in water of andere
vloeistoffen onderdompelen.
Nooit oplosmiddelen gebruiken om
regelaar schoon te maken.
Naast schoonmaken is geen verder
onderhoud nodig.
Verzorging van de regelaar
De bediening van de regelaar
Het gebruik van uw regelaar
1. Aan/Uit schakelaar 8. Montageframe
2. Aanzuig/Afzuig schakelaar 9. Wanddoos
3. Hoog/Laag toerental 10.Kunststof ombouw
4. Verklikkerlampje 11.Klemmenblok regeleenheden
5. Ventilatiegroeven 12.Klemmenblok ventilator
6. Schroefdop 13.Dubbelpolig scheidingsschakelaar
7. Bedieningspaneel 14.Zekeringen
De regelaar kan voor het volgende worden gebruikt:
(Zie tekeningen F1 - F4.)
1. Maak het bedieningspaneel los van het montageframe door
verwijdering van de schroefdoppen en twee schroeven. (Zie
Afb. 2a & 2b.)
2. Maak het montageframe los van de wanddoos door verwijdering
van de twee schroeven. (Zie Afb. 2c.)
3. Til de wanddoos uit de kunststof ombouw.
4. Controleer of de toelaatbare nominale waarde in de regelaar
overeenkomt met de stroomtoevoer.
5. Maak de aardleiding los van de wanddoos.
6. Maak kabel-ingangsgaten in de kunststof en metalen dozen door
verwijdering van de toepasselijke uitbreekplaatjes. (Zie Afb. 1.)
Controleer of er geen verborgen leidingen of
kabels in de muur zitten, danwel of er zich
obstructies aan de buitenkant van de muur
bevinden, zoals elektriciteit, gas of water.
Voor vaste bedradingscircuits mag de beschermende
zekering voor het apparaat 5 amp niet overschrijden.
Ein zweipoliger Netztrennschalter mit einer Kontaktöffnung
von 3 mm (an Wand oder Decke montiert).
Ausreichend dimensionierte fünfadrige Anschlußleitung
zum Anschließen des Reglers an den Ventilator. Bei
Fenstereinbau des Ventilators sollte eine flexible
Anschlußleitung verwendet werden (bei Xpelair erhältlich).
Ausreichend dimensionierte dreiadrige Anschlußleitung
zwischen Ventilator und Netzstromversorgung.
Falls eine flexible Anschlußleitung verwendet
wird, muß für ausreichende Zugentlastung
gesorgt werden (siehe Abb. 1).
Die vorliegende Anleitung bezieht sich nur auf die Installation und den Betrieb des Ventilatorreglers
FR22/30. Die Installations- und Betriebsanleitung für den Ventilator entnehmen Sie bitte dem mit dem
betreffenden Ventilator mitgelieferten Informationsmaterial.
Der Regler darf nicht an Stellen installiert werden, an
denen eine Umgebungstemperatur von +50°C
überschritten werden könnte.
Der Regler darf nicht in unmittelbarer Nähe von
Herdplatten, Dunstabzugshauben oder anderen
Wandöffnungen montiert werden.
Falls der Ventilator zur Förderung möglicherweise
chemisch korrodierender Atmosphäre vorgesehen ist,
sollten Sie mit Ihrem örtlichen Xpelair-Händler
Verbindung aufnehmen (Großbritannien: bitte wenden
Sie sich an den Technischen Kundendienst von
Xpelair).
Beim Einbau in einem Badezimmer/Duschraum
müssen Regler und Netztrennschalter gemäß den
einschlägigen Bestimmungen und so positioniert
werden, daß sie vom Bad/von der Dusche aus
nicht berührt werden können.
Dieses Gerät ist zum Regeln des Betriebs von Xpelair-
Ventilatoren der Baureihen GX9, GX12, WX9, WX12, RX9
und RX12 (wand- und fenstermontiert) bestimmt. Der Regler
ist für Auf- und Unterputzinstallation geeignet (nur
Großbritannien). Es darf nur maximal ein Ventilator pro Regler
angeschlossen werden.
Zum Zweck dieser Anleitung werden derzeitige und ältere
Ventilatorversionen wie folgt entweder Typ A oder Typ B
zugeordnet:
Beim Anschließen an Ventilatoren des Typs A
Die Brücke zwischen den Anschlußklemmen 2 und 3 in
der Anschlußbuchse des Ventilators muß vor dem
Anschließen des Reglers entfernt werden. Wird die
Brücke nicht entfernt, kann das zu einer dauerhaften
Beschädigung des Reglers führen.
Beim Anschließen an Ventilatoren des Typs B
Das Entfernen der Brücke ist hier nicht erforderlich.
Falls der Ventilator bereits installiert ist
1 Stellen Sie sicher, daß eine allpolige Netztrennung
gegeben ist.
2 Trennen Sie den Netzanschluß von der Steckbuchse
bzw. vom Klemmenbrett.
3 Überprüfen Sie die vorhandene Verdrahtung auf
elektrische Sicherheit.
1 Verlegen Sie das fünfadrige Kabel zwischen Ventilator und
Regler.
2 Schließen Sie ein Ende des Kabels wie abgebildet an die
Anschlüssen des Ventilators an:
3 Das andere Ende dient zum Anschluß an den Regler.
Typ A1
Typ A2
Typ B1
Typ B2
Installationsort des Reglers
Verdrahten der elektrischen Anschlüsse des Ventilators
Beschreibung
Was zur Installation benötigt wird
Bestimmen des Ventilatortyps
Vorbereitung des Ventilators
Allgemeine Informationen Arbeiten am Ventilator
Falls der Ventilator noch nicht installiert ist:
1 Überprüfen Sie, ob die elektrischen Anschlußdaten des
Ventilators mit denen der Netzstromversorgung
übereinstimmen.
VENTILATORTYP
F1
F2
F3
ANSCHLUSSDIAGRAMM
Typ A1
Typ A2
Typ B
Tabelle 1
Falls der Ventilator an eine existierende Anlage
angeschlossen werden soll, ist für eine
allpolige Netztrennung zu sorgen und die
betreffenden Sicherungen sind zu entfernen,
bevor mit Elektroarbeiten begonnen wird.
Installations- und Betriebsanleitung -
Ventilatorregler FR22/30
Diese Installationsanleitung behandelt die Installation des
Reglers bei Verwendung in Verbindung mit Ventilatoren von
Xpelair.
Der Regler muß an eine Festverdrahtung
angeschlossen werden. Stellen Sie sicher,
daß die auf dem Reglergehäuse angegebenen
Nennwerte mit der Netzstromversorgung
übereinstimmen. Dieses Gerät muß geerdet
werden.
Alle Installationsarbeiten dürfen nur von einer qualifizierten
Elektrofachkraft ausgeführt werden. In Großbritannien sind
Installation und Verdrahtung gemäß den derzeitig gültigen
IEE-Bestimmungen auszuführen. In anderen Ländern sind
die jeweils geltenden nationalen Vorschriften einzuhalten.
Installation des Reglers
Sollten Sie vor, bei oder nach der Installation des Reglers
irgendwelche Fragen haben, wenden Sie sich bitte an die
britische Xpelair-Hotline (Telefonnummer siehe Rückseite).
Nicht in Großbritannien befindliche Kunden von Xpelair
wenden sich an ihren örtlichen Xpelair-Händler.
D
Entfernen der Abdeckung und des Montagerahmens
Während der gesamten Dauer der Bohr- und
Meißelvorgänge muß ein Augenschutz getragen
werden.
Montage des Wandkastens
Bei Aufputzmontage
1 Setzen Sie geeignete Kabelverschraubungen in die
Ausbrüche ein.
2 Führen Sie beide Kabel durch diese Verschraubungen.
3 Befestigen Sie den Wandkasten und die Kunststoffeinfassung
über die vorgesehenen Montagelöcher an der Wand.
4
Schließen Sie den Erdungsleiter wieder am Wandkasten an.
Bei Unterputzeinbau
1 Fertigen Sie eine Vertiefung in der Wand zur Aufnahme des
Wandkastens an. Die Kunststoffeinfassung wird für die
Unterputzmontage nicht benötigt.
2 Setzen Sie geeignete Kabelverschraubungen in die Ausbrüche
ein.
3 Führen Sie beide Kabel durch diese Verschraubungen.
4 Befestigen Sie den Wandkasten an der Wand. Achten Sie
darauf, daß der Flansch des Montagerahmens an der fertigen
Wandoberfläche bündig anliegt (siehe Diagramm F6).
5 Schließen Sie den Erdungsleiter wieder am Wandkasten an.
Elektrischer Anschluß des Reglers
1 Montieren Sie den Netztrennschalter gemäß der Anleitung des
Herstellers.
2 Schließen Sie den Regler in Übereinstimmung mit dem
entsprechenden Diagramm an den Netztrennschalter und den
Ventilator an (siehe Tabelle 1).
3 Bringen Sie den Montagerahmen wieder am Wandkasten
(Metall) an.
4 Bringen Sie die Frontplatte wieder am Montagerahmen an.
5 Bringen Sie die Schraubenabdeckungen wieder an.
1 Stellen Sie sicher, daß eine allpolige Netztrennung
gegeben ist und die Sicherungen entfernt werden.
2 Verlegen Sie das Kabel vom Netztrennschalter zum
Netzstromversorgungsanschlußpunkt.
3 Stellen Sie in Übereinstimmung mit der Anleitung des
Herstellers alle Anschlüsse im Netztrennschalter her.
4 Stellen Sie unter Einhaltung aller einschlägigen Vorschriften
den Netzstromanschluß her.
5 Überprüfen Sie abschließend, daß alle Erdungspunkte
angeschlossen sind und alle Abdeckungen an Ventilator,
Regler und Netztrennschalter wieder richtig angebracht worden
sind.
6 Setzen Sie alle Sicherungen wieder ein und schalten Sie die
Netzstromversorgung ein.
(Großbritannien:) Bei Festverdrahtung darf die
Schutzsicherung für das Gerät den Nennstrom von 5 A nicht
überschreiten.
Nur Australien:
Diese Modelle sind permanent an die Stromversorgung
angeschlossen und ihr Betrieb wird über einen separaten Schalter
gesteuert. Sie sollten durch einen zugelassenen aufputzmontierten
10-A-Schalter mit einem Mindestabstand von 3 mm zwischen
Kontakten direktverdrahtet sein.
Montage des Reglers
1 Lösen Sie die Frontplatte vom Montagerahmen, indem Sie die
Schraubenabdeckungen abnehmen und die zwei Schrauben
entfernen (siehe Abb. 2a und 2b).
2 Lösen Sie den Montagerahmen vom Wandkasten durch
Herausschrauben der zwei Schrauben (siehe Abb. 2c).
3 Ziehen Sie den Wandkasten von der Kunststoffeinfassung ab.
4 Überprüfen Sie, ob die elektrische Auslegung auf der Innenseite
des Reglers mit der Stromversorgung übereinstimmt.
5 Klemmen Sie den Erdungsanschluß vom Wandkasten ab.
6 Öffnen Sie die Kabeleingangslöcher in den Kunststoff- und
Metallkästen durch Ausbrechen der vorgesehenen
Sollbruchstellen (siehe Abb. 1).
Anschluß an die Stromversorgung
Reinigung
1 Der Regler ist vor der Reinigung allpolig vom Netz zu trennen.
2 Die Abdeckung sorgfältig mit einem feuchten Tuch abwischen.
3 Gründlich abtrocknen.
4 Stellen Sie sicher, daß die Lüftungsschlitze nie verdeckt oder
verstopft werden.
Der Regler darf auf keinen Fall in Wasser oder andere
Flüssigkeiten eingetaucht werden.
Den Regler niemals mit Lösungsmitteln reinigen.
Abgesehen von der Reinigung ist keine weitere
Wartung erforderlich.
Instandhaltung des Reglers
Betrieb des Reglers
Benutzung des Reglers
1 Ein/Aus-Schalter
2 Zuluft/Abluft-Schalter
3 Hohe/Niedrige Geschwindigkeit
4 Betriebsleuchte
5 Lüftungsschlitze
6 Schraubenabdeckung
7 Frontplatte
8 Montagerahmen
9 Wandkasten
10 Kunststoffeinfassung
11 Klemmenbrett des Reglers
12 Klemmenbrett des Ventilators
13 Zweipoliger Netztrennschalter
14 Sicherungen
Der Regler besitzt folgende Funktionen
(siehe Diagramme F1 - F4):
Vergewissern Sie sich, daß sich an der
gewünschten Montageposition keine
eingelassenen Leitungen, wie z.B. Strom-, Gas-
oder Wasserleitungen, befinden, welche bei der
Installation eventuell beschädigt werden
könnten.
Abb.1 Abb.2a : Abb.2b: Abb.2c:
Positionen der Kabelverschraubungen Abnehmen der Schraubenabdeckungen Abnehmen der Frontplatte Abnehmen des Montagerahmens
A
Un interrupteur bipolaire de coupure avec intervalle de
coupure minimal de 3 mm (Montage mural ou au plafond).
Un câble à 5 conducteurs de caractéristiques adéquates
pour relier le contrôleur au ventilateur. Si le ventilateur
est monté sur une fenêtre, utilisez un câble souple.
(Disponible chez Xpelair).
Un câble à 3 conducteurs de caractéristiques adéquates
pour relier le contrôleur à l’alimentation secteur.
Si vous utilisez un câble flexible, des presse-
étoupe adéquats équipés de colliers de
serrage doivent être montés sur les pastilles
préformées de la boîte du contrôleur. (Voir
Fig. 1).
Ces instructions concernent uniquement l’installation et l’utilisation du contrôleur de ventilateur FR22/30. Pour les instructions
sur l’installation et l’utilisation du ventilateur, référez-vous aux documents
Pas où les températures ambiantes peuvent
dépasser 50°C.
S’il est installé dans une cuisine, le contrôleur ne
doit pas être monté directement au dessus d’une
hotte de cuisinière ou d’un grill à hauteur d’oeil.
S’il est destiné à être utilisé dans des atmosphères
chimiques pouvant être corrosives, demandez
conseil à notre Service Technique. (En dehors du
Royaume-Uni, contactez votre distributeur Xpelair
local).
S’il est installé dans une salle de douche ou une
salle de bain, le contrôleur et lecommutateur
d’isolation doivent être placés de manière qu’ils ne
puissent être touchés par les personnes utilisant le
bain ou la douche.
Cet appareil est conçu pour contrôler le fonctionnement des
ventilateurs Xpelair des gammes GX9, GX12, WX9, WX12,
RX9 et RX12 (montage mural et sur fenêtres). Le contrôleur
peut être soit monté en saillie, soit encastré dans sa propre
boîte
.
Vous ne devez pas relier plus d’un ventilateur à chaque
contrôleur
Pour les besoins de ces instructions, les versions actuelles
et précédentes des ventilateurs sont identifiées en Type A &
Type B, comme suit :
Dans le cas de câblage à des ventilateurs de Type A
Il y a un cavalier entre les bornes 2 et 3 dans la prise du
ventilateur, et ce cavalier doit être retiré avant de relier le
contrôleur. Si vous ne le retirez pas, le contrôleur sera
définitivement endommagé.
Dans le cas de câblage à des ventilateurs de Type B
Il n’y a pas de cavalier à retirer.
Si le ventilateur est déjà installé
1 Assurez-vous que l’alimentation secteur est coupée.
2 Débranchez les connexions du secteur de la prise à
bornes du ventilateur ou du bornier.
3 Retirez les fils existants et mettez en sécurité.
1 Faites passer le câble à 5 conducteurs du ventilateur au
contrôleur
2 Reliez une extrémité du câble aux connexions du
ventilateur comme indiqué ci-après :
3 Laissez l’autre extrémité prête à être reliée au contrôleur
Type A1
Type A2
Type B1
Type B2
Emplacement du contrôleur
Câblage des connexions électriques du ventilateur
Description
Ce dont l’installateur a besoin
Identification du type de ventilateur
Préparation du ventilateur
Informations Générales
Si le ventilateur n’est pas encore installé
1 Vérifiez que les caractéristiques électriques du ventilateur
correspondent à l’alimentation électrique.
Dans le cas de câblage à une installation
existante, isolez l’alimentation secteur et
retirez les fusibles concernés avant toute
procédure électrique
Instructions d’installation et d’utilisation du
Contrôleur de ventilateur FR22/30
Ces instructions d’installation concernent l’installation du
contrôleur lorsqu’il est utilisé avec des ventilateurs fournis
par Xpelair.
Le contrôleur doit être relié à un câblage
fixe. Assurez-vous que l’alimentation secteur
correspond aux caractéristiques indiquées
sur le boîtier du contrôleur. Cet appareil
doit être mis à la terre.
Toutes les installations doivent être supervisées par un
électricien qualifié. L’installat(ion et le câblage doivent être
conformes aux règlements actuels IEE (R-U), ou aux
règlements locaux appropriés (autres pays).
Si vous avez des questions avant, pendant et après
l’installation du contrôleur, n’hésitez pas à contacter le
numéro britannique d’urgence de Xpelair (numéro sur la
dernière page). Pour les clients hors du Royaume-Uni,
contactez votre distributeur Xpelair local.
Utilisation du ventilateur
TYPE
F1
F2
F3
SCHEMA
Type A1
Type A2
Type B
Tableau 1.
Installation du contrôleur
F
Type B, comme suit:
Retrait du couvercle et du cadre de montage
Des lunettes de protection doivent être
portées pendant tout perçage ou burinage.
Vérifiez qu’il n’y a aucune tuyauterie ou
câble enfoui dans le mur ou d’obstructions
à l’extérieur, par ex. électricité, gaz, eau.
Montage du boîtier mural
Pour le montage en saillie
1 Insérer des manchons appropriés dans les pastilles
préformées
2 Faites passer les deux câbles dans les manchons
3 Fixez le boîtier mural et la bordure en plastique au mur, à
l’aide des trous d’assemblage prévus
4 Reliez à nouveau le fil de terre au boîtier mural
Pour le montage encastré
1 Faites un trou dans le mur suffisamment grand pour
loger le boîtier mural. Jetez la bordure en plastique
2 Insérez des manchons appropriés dans les pastilles
préformées
3 Faites passer les deux câbles dans ces manchons
4 Fixez le boîtier au mur. Assurez-vous que la bride du
cadre de montage affleure la surface finie du mur. (Voir
le schéma F6).
5 Rebrancher le fil de terre sur le boîtier encastré.
Câblage des connexions électriques du contrôleur
1 Montez le commutateur d’isolation conformément aux
instructions des fabricants.
2 Câblez le contrôleur au commutateur d’isolation et au
ventilateur comme illustré sur le schéma approprié. (Voir
le Tableau 1).
3 Remontez le cadre de montage dans le boîtier mural
4 Remontez l la face sur le cadre de montage
5 Remontez les couvre-vis
1 Assurez-vous que l’alimentation secteur est coupée
et que les fusibles sont retirés
2 Faites passer le câble entre le commutateur d’isolation et
le point de connexion à l’alimentation secteur
3 Faites toutes les connexions dans le commutateur
d’isolation conformément aux instructions des fabricants.
4 En respectant tous les règlements locaux, branchez à
l’alimentation secteur.
5 Faites une dernière vérification pour assurer que tous les
points de mise à la terre sont connectés et que tous les
couvercles ont été correctement remis sur le ventilateur,
le contrôleur et le commutateur d’isolation.
6 Remettez tous les fusibles, et mettez sous tension secteur.
Pour des circuits avec raccordement fixe, le fusible de
protection de l’appareil ne doit pas dépasser 5 A.
Pour l’Australie uniquement :
Ces modèles sont reliés de manière permanente à
l’alimentation et le fonctionnement est commandé par un
interrupteur à distance. Ces modèles doivent être câblés
directement au secteur à l’aide d’un commutateur mural de
10 A approuvé, avec un écartement des contacts d’au moins
3 mm
Montage du contrôleur
1 Enlever l’avant du cadre de montage en retirant les
couvercles de vis et les deux vis. (Voir la Fig. 2a&b).
2 Enlever le cadre de montage du boîtier mural en retirant
les deux vis. (Voir la Fig. 2c).
3. Retirez le boîtier de la bordure en plastique.
4 Vérifiez que la puissance électrique indiquée à l’intérieur
du contrôleur correspond à celle de l’alimentation principale.
5 Débranchez du boîtier mural le fil de mise à la terre.
6 Faites des trous d’entrée pour le câble dans les boîtiers
en plastique et métalliques en retirant les pastilles
préformées appropriées. (Voir la Fig. 1).
Connectez au secteur
Fig. 1 :
Positions des presse-étoupe
1 Avant de nettoyer, isolez complètement le contrôleur
de l’alimentation électrique
2 Essuyez le couvercle soigneusement avec un chiffon humide
3 Séchez complètement
4 Assurez-vous toujours que les fentes de ventilation ne
sont pas bouchées.
N’immergez jamais le contrôleur dans
de l’eau ou un autre liquide
N’utilisez jamais de solvants forts pour
nettoyer le contrôleur
A part le nettoyage, aucun autre
entretien n’est nécessaire.
Entretien du contrôleur
Utilisation de votre contrôleur
1 Commutateur Marche/Arrêt
2 Commutateur aspiration/
extraction
3 Vitesse rapide/lente
4 Voyant lumineux
5 Fentes de ventilation
6 Couvercle de vis
7 Face
Le contrôleur comporte les caractéristiques suivantes : (Voir
les schémas F1-F4).
Fig. 2a :
Retrait des couvercles de vis
Fig. 2c :
Retrait du cadre de montage
Fig. 2b :
Retrait de la face
8 Cadre de montage
9 Boîtier mural
10Bordure plastique
11Bornier du contrôleur
12Bornier du ventilateur
13Interrupteur bipolaire de
coupure
14Fusibles
Fonctionnement du contrôleur Nettoyage
Un isolatore bipolare con una distanza minima tra i contatti
di 3 mm (montaggio a parete o a soffitto).
Cavo a 5 conduttori per collegare il regolatore al ventilatore.
Se il ventilatore è montato su una finestra usare un cavo
flessibile (disponibile presso Xpelair).
Cavo a 3 conduttori per collegare il regolatore
all'alimentazione di rete.
Se si usa un cavo flessibile, si devono montare
opportuni pressatreccia, che incorporano
morsetti serrafilo, ai fori incompleti nella
cassetta del regolatore (vedere fig. 1).
Queste istruzioni sono soltanto per l'installazione ed il funzionamento del Regolatore FR22/30. Per le istruzioni
di installazione e funzionamento del ventilatore consultare la documentazione fornita con il relativo ventilatore.
Non posizionare il regolatore dove la temperatura
ambiente potrebbe superare 50ºC.
Se viene installato in una cucina, non si deve montare
il regolatore sopra una cappa di aspirazione o un grill
all'altezza del viso.
Se si prevede l'uso in atmosfere corrosive da sostanze
chimiche, consultare il distributore locale Xpelair.
Se vengono installati in una stanza da bagno o doccia,
il regolatore e l'isolatore devono essere posizionati in
modo che non possano essere toccati da chi usa il
bagno o la doccia.
Questo dispositivo è stato progettato per regolare il
funzionamento dei ventilatori Xpelair della gamma GX9,
GX12, WX9, WX12, RX9 e RX12 (montati a parete e su
finestra). Il regolatore può essere montato in superficie oppure
a incasso nella propria cassetta di metallo zincato. Si deve
cablare un solo ventilatore a ciascun regolatore.
Ai fini di queste istruzioni, le versioni correnti e precedenti dei
ventilatori sono identificate come Tipo A e Tipo B, come segue:
Cablaggio a ventilatori Tipo A
Nella presa del ventilatore, tra i morsetti 2 e 3 è montato
un filo fusibile che deve essere tolto prima di collegare il
regolatore, altrimenti il regolatore sarà permanentemente
danneggiato.
Cablaggio a ventilatori Tipo B
Non è presente filo fusibile da togliere.
Se il ventilatore è già installato:
1 Assicurarsi che l'alimentazione elettrica sia isolata.
2 Scollegare le connessioni di rete dalla presa terminale
del ventilatore o dal blocco terminale.
3 Togliere il cablaggio esistente e renderlo sicuro.
1 Instradare il cavo a 5 conduttori dal ventilatore alla
posizione del regolatore.
2 Cablare un'estremità del cavo nelle connessioni del
ventilatore come indicato di seguito:
3 Lasciare l'altra estremità pronta per essere collegata al
regolatore.
Tipo A1
Tipo A2
Tipo B1
Tipo B2
Posizionamento del regolatore
Cablaggio delle connessioni elettriche del
ventilatore
Descrizione
Che cosa occorre all'installatore
Identificazione del tipo di ventilatore
Preparazione
Informazioni Generali Operazioni con i ventilatori
Se il ventilatore non è ancora installato:
1 Controllare che l'alimentazione elettrica nominale del
ventilatore corrisponda all'alimentazione di rete.
TIPO DI VENTILATORE
F1
F2
F3
DIAGRAMMA
Tipo A1
Tipo A2
Tipo B
Tabella 1.
Se si deve effettuare il collegamento ad
un'installazione già esistente, isolare
l'alimentazione di rete e togliere i relativi
fusibili prima di qualunque procedura
elettrica.
Istruzioni per l'installazione ed il funzionamento
del Regolatore FR22/30 per ventilatori
Queste istruzioni sono intese per l'installazione del regolatore
quando viene usato con ventilatori forniti da Xpelair.
Il regolatore deve essere installato con
cablaggio fisso. Controllare che
l'alimentazione di rete corrisponda ai dati
riportati sull'alloggiamento del regolatore.
Questo dispositivo deve essere collegato a
massa.
Tutte le installazioni devono essere eseguite sotto la
supervisione di un elettricista qualificato. L'installazione e i
cablaggi devono essere conformi alle norme IEE (Regno
Unito) o alle relative norme locali (per altri Paesi).
Se si desiderano ulteriori informazioni prima, durante e
dopo l'installazione del regolatore, rivolgersi al numero
di assistenza Xpelair nel Regno Unito (riportato all'ultima
pagina). Clienti fuori del Regno Unito: rivolgersi al
distributore locale Xpelair.
Installazione del regolatore
I
Togliere il coperchio e il telaio di montaggio
Durante le operazioni di trapanatura e
scalpellatura si devono indossare protezioni
per gli occhi.
Montaggio della cassetta a parete
Montaggio in superficie
1 Inserire pressatreccia adatti nei fori incompleti.
2 Far passare entrambi i cavi nei pressatreccia.
3 Fissare al muro la cassetta e la cornice di plastica
utilizzando i fori di montaggio forniti.
4 Ricollegare il filo di massa alla cassetta a parete.
Montaggio a incasso
1 Praticare nella parete un foro abbastanza grande per
alloggiare la cassetta. Gettare la cornice di plastica.
2 Inserire pressatreccia adatti nei fori incompleti.
3 Far passare entrambi i cavi nei pressatreccia.
4 Fissare la cassetta alla parete. Assicurarsi che la flangia
del telaio di montaggio sia a filo con la superficie della
parete (vedere il diagramma F6).
5 Ricollegare il filo di massa alla cassetta a parete.
Cablaggio delle connessioni elettriche del regolatore
1 Montare l'isolatore seguendo le istruzioni del fabbricante.
2 Cablare il regolatore all'isolatore ed al ventilatore, come
indicato nel relativo diagramma (vedere la Tabella 1).
3 Rimontare il telaio di montaggio alla cassetta metallica a
parete.
4 Rimontare il pannello al telaio di montaggio.
5 Rimettere i coperchi alle viti.
1 Assicurarsi che l'alimentazione elettrica sia isolata e
che i fusibili siano stati tolti.
2 Far passare il cavo dall'isolatore al punto di connessione
con l'alimentazione elettrica.
3 Eseguire tutte le connessioni nell'isolatore conformemente
alle istruzioni del fabbricante.
4 Eseguire le connessioni al punto dell'alimentazione elettrica
seguendo tutte le norme vigenti localmente.
5 Eseguire una verifica finale per assicurarsi che tutti i punti
di massa siano collegati e che tutte le coperture siano state
rimesse a posto nel modo giusto sul ventilatore, regolatore
ed isolatore.
6 Rimettere tutti i fusibili ed inserire l'alimentazione elettrica.
Per i circuiti a cablaggio fisso, il fusibile di protezione
dell'apparecchio non deve essere superiore a 5 amp.
Solo per l'Australia:
Questi modelli sono collegati in permanenza all'alimentazione
e il funzionamento è controllato da un interruttore remoto. I
modelli devono essere cablati direttamente all'alimentazione
tramite un interruttore di 10 amp approvato, montato in
superficie sulla parete con almeno 3 mm di spazio tra i contatti.
Montaggio del regolatore
1 Smontare la parte anteriore dal telaio di montaggio togliendo
le coperture delle viti e due viti (vedere figg. 2a e 2b).
2 Staccare il telaio dalla cassetta a parete togliendo le due viti
(vedere fig. 2c).
3 Allontanare la cassetta sollevandola dalla cornice di plastica.
4 Controllare che i dati elettrici nominali riportati all'interno del
regolatore corrispondano all'alimentazione elettrica.
5 Scollegare il filo di massa dalla cassetta a parete.
6 Praticare fori di ingresso dei cavi nella cassetta di plastica e
in quella di metallo aprendo i fori incompleti (vedere fig. 1).
Collegamento dell'alimentazione elettrica
Fig. 1 : Fig. 2a : Fig. 2b: Fig. 2c:
Pulizia
1 Prima di procedere alla pulizia isolare completamente
il regolatore dall'alimentazione elettrica.
2 Pulire delicatamente il coperchio con un panno umido.
3 Asciugare bene.
4 Assicurarsi che le fessure di ventilazione non siano mai
ostruite.
Non immergere mai il regolatore in acqua
o altri liquidi.
Non usare mai solventi per pulire il
regolatore.
Tranne la pulizia, non è necessaria altra
manutenzione.
Manutenzione del regolatore
Funzionamento del regolatore
Impiego del regolatore
1 Interruttore On/Off 8 Telaio di montaggio
2 Interruttore aspirazione/ 9 Cassetta a parete
estrazione 10 Cornice di plastica
3 Velocità alta/bassa 11 Blocco morsetti regolatore
4 Spia luminosa 12 Blocco morsetti ventilatore
5 Fessure di ventilazione 13 Isolatore bipolare
6 Copri vite 14 Fusibili
7 Pannello
Il regolatore ha le seguenti caratteristiche.
(vedere i diagrammi F1-F4).
Check there are no buried Pipes or Cables
in the wall or obstructions on the outside
e.g. Electricity, Gas, Water.
Posizioni dei pressatreccia del cavo Rimozione dei coperchi delle viti Rimozione del pannello Rimozione del telaio di montaggio
Controllare che non vi siano tubi o cavi
nascosti nel muro o ostruzioni all’esterno, per
es. condotte per elettricità, gas, acqua.
Û˘Û΢‹ ÚÔÔÚ›˙ÂÙ·È ÁÈ· ÙË Ú‡ıÌÈÛË Ù˘ ÏÂÈÙÔ˘ÚÁ›·˜ ÙˆÓ
ÂÍ·ÂÚÈÛÙ‹ÚˆÓ Xpelair ÙˆÓ ÛÂÈÚÒÓ GÃ9, GX12, WX9, WX12,
RX9 Î·È RX12 (Ô˘ ÙÔÔıÂÙÔ‡ÓÙ·È Û ÙÔ›¯Ô˘˜ Î·È ·Ú¿ı˘Ú·).
Ú˘ıÌÈÛÙ‹˜ ÌÔÚ› Ó· ÙÔÔıÂÙÂ›Ù·È Û ÂÈÊ¿ÓÂÈ· ‹ Û ÂÛÔ¯‹
̤۷ ÛÙÔ ‰ÈÎfi ÙÔ˘ ÎÈ‚ÒÙÈÔ. ªÔÚ›Ù ӷ ηψ‰ÈÒÛÂÙ ÌfiÓÔ
¤Ó· ÂÍ·ÂÚÈÛÙ‹Ú· Û οı ڢıÌÈÛÙ‹.
√È Ô‰ËÁ›Â˜ ·˘Ù¤˜ ÈÛ¯‡Ô˘Ó ÁÈ· ÙËÓ ÂÁηٿÛÙ·ÛË ÙÔ˘ Ú˘ıÌÈÛÙ‹
fiÙ·Ó ¯ÚËÛÈÌÔÔÈÂ›Ù·È ÛÂ Û˘Ó‰˘·ÛÌfi Ì ÂÍ·ÂÚÈÛÙ‹Ú˜ Ô˘
ÚÔÌËı‡ÔÓÙ·È ·fi ÙËÓ Xpelair.
ÂÁηٿÛÙ·ÛË ÙÔ˘ Ú˘ıÌÈÛÙ‹ Ú¤ÂÈ Ó· Á›ÓÂÙ·È
Û ÛÙ·ıÂÚ‹ ηψ‰›ˆÛË. µÂ‚·Èˆı›Ù fiÙÈ Ë
‰È·‚¿ıÌÈÛË Ù˘ ÎÂÓÙÚÈ΋˜ ËÏÂÎÙÚÈ΋˜ ·ÚÔ¯‹˜
Â›Ó·È Û‡ÌʈÓË Ì ÙË ‰È·‚¿ıÌÈÛË Ô˘ ·Ó·Ê¤ÚÂÙ·È
ÛÙÔ ÂÚ›‚ÏËÌ· ÙÔ˘ Ú˘ıÌÈÛÙ‹. Û˘Û΢‹ ·˘Ù‹
Ú¤ÂÈ Ó· ÁÂÈÒÓÂÙ·È.
fiÏË ÂÁηٿÛÙ·ÛË Ú¤ÂÈ Ó· ÂȂϤÂÙ·È ·fi ÂȉÈÎÂ˘Ì¤ÓÔ
ËÏÂÎÙÚÔÏfiÁÔ. ∏ ÂÁηٿÛÙ·ÛË Î·È Ë Î·Ïˆ‰›ˆÛË Ú¤ÂÈ Ó·
Û˘ÌÌÔÚÊÒÓÔÓÙ·È ÚÔ˜ ÙÔ˘˜ ÙÚ¤¯ÔÓÙ˜ ηÓÔÓÈÛÌÔ‡˜ ÙÔ˘ π∂∂
(ÛÙÔ ∏ӈ̤ÓÔ µ·Û›ÏÂÈÔ) ÙÔ˘˜ Û¯ÂÙÈÎÔ‡˜ ÂıÓÈÎÔ‡˜
ηÓÔÓÈÛÌÔ‡˜ (Û ¿ÏϘ ¯ÒÚ˜).
Ó ¤¯ÂÙ ÔÔÈÂÛ‰‹ÔÙ ÂÚˆÙ‹ÛÂȘ ÚÈÓ, ηٿ Î·È ÌÂÙ¿ ÙËÓ
ÂÁηٿÛÙ·ÛË ÙÔ˘ Ú˘ıÌÈÛÙ‹, ·Ú·Î·Ï›Ûı ӷ ÌË ‰ÈÛÙ¿ÛÂÙÂ
Ó· ÂÈÎÔÈÓˆÓ‹ÛÂÙ Ì ÙËÓ ÙËÏÂʈÓÈ΋ ÁÚ·ÌÌ‹ ¿ÌÂÛ˘
Û‡Ó‰ÂÛ˘ (hotline) Ù˘ Xpelair ÛÙÔ ∏ӈ̤ÓÔ µ·Û›ÏÂÈÔ
(‚Ϥ ·ÚÈıÌfi ÛÙËÓ ›Ûˆ ÛÂÏ›‰·). √È ÂÎÙfi˜ ∏ӈ̤ÓÔ˘
µ·ÛÈÏ›Ԣ ÂÏ¿Ù˜ ÌÔÚÔ‡Ó Ó· ÂÈÎÔÈÓˆÓÔ‡Ó Ì ÙÔÓ ÙÔÈÎfi
‰È·ÓÔ̤· Ù˘ Xpelair.
¢ÈÔÏÈÎfi˜ ‰È·ÎfiÙ˘ ·ÔÌfiÓˆÛ˘ Ì ÂÏ¿¯ÈÛÙÔ ÎÂÓfi
Â·Ê‹˜ 3 ¯ÛÙ. (ÁÈ· ÂÁηٿÛÙ·ÛË ÙÔ›¯Ô˘ ‹ ·Ú·ı‡ÚÔ˘).
∫·Ù¿ÏÏËÏ˘ ‰È·‚¿ıÌÈÛ˘ ηÏÒ‰ÈÔ 5 ˘Ú‹ÓˆÓ ÁÈ· ÙË
Û‡Ó‰ÂÛË ÙÔ˘ Ú˘ıÌÈÛÙ‹ Ì ÙÔÓ ÂÍ·ÂÚÈÛÙ‹Ú·. ∞Ó ÚfiÎÂÈÙ·È
ÁÈ· ÂÍ·ÂÚÈÛÙ‹Ú· ÙÔ›¯Ô˘, ¯ÚËÛÈÌÔÔÈ‹ÛÙ ‡ηÌÙÔ
ηÏÒ‰ÈÔ (Ô˘ ‰È·Ù›ıÂÙ·È ·fi ÙËÓ Xpelair).
∫·Ù¿ÏÏËÏ˘ ‰È·‚¿ıÌÈÛ˘ ηÏÒ‰ÈÔ 3 ˘Ú‹ÓˆÓ ÁÈ· ÙË
Û‡Ó‰ÂÛË ÙÔ˘ Ú˘ıÌÈÛÙ‹ Ì ÙËÓ ÎÂÓÙÚÈ΋ ËÏÂÎÙÚÈ΋
·ÚÔ¯‹.
∞Ó ¯ÚËÛÈÌÔÔÈËı› ‡ηÌÙÔ Î·ÏÒ‰ÈÔ, ÛÙȘ
ÙÚ‡˜ ÙÔ˘ ÎÈ‚ˆÙ›Ô˘ ÙÔ˘ Ú˘ıÌÈÛÙ‹ Ú¤ÂÈ Ó·
ÙÔÔıÂÙËıÔ‡Ó Î·Ù¿ÏÏËÏÔÈ Û˘Ó‰ÂÙÈÎÔ› ‰·ÎÙ‡ÏÈÔÈ
Ì ÂÓۈ̷و̤ÓÔ˘˜ ηψ‰È·ÎÔ‡˜ Û˘Ó‰¤ÛÌÔ˘˜
(‚Ϥ ™¯. 1).
Ÿ¯È Û ÛËÌ›· fiÔ˘ Ë ÂÚÈ‚·ÏÏÔÓÙÈ΋ ıÂÚÌÔÎÚ·Û›· ›ӷÈ
Èı·Ófi Ó· ˘ÂÚ‚·›ÓÂÈ ÙÔ˘˜ 50ÆC.
∞Ó ÚfiÎÂÈÙ·È ÁÈ· ÂÁηٿÛÙ·ÛË Û ÎÔ˘˙›Ó·, Ô Ú˘ıÌÈÛÙ‹˜
‰ÂÓ Ú¤ÂÈ Ó· ÙÔÔıÂÙÂ›Ù·È ·Ì¤Ûˆ˜ ¿Óˆ ·fi ÙËÓ
ÂÈÊ¿ÓÂÈ· Û˘Û΢‹˜ ÎÔ˘˙›Ó·˜ ¿Óˆ ·fi Û¯¿Ú·
ÂÈ¤‰Ô˘ Ì·ÙÈÒÓ.
∞Ó ÚÔÔÚ›˙ÂÙ·È ÁÈ· ¯Ú‹ÛË Û Èı·ÓÒ˜ ¯ËÌÈο
‰È·‚ÚˆÙÈΤ˜ ·ÙÌfiÛÊ·ÈÚ˜, Û˘Ì‚Ô˘Ï¢ı›Ù ÙÔ ∆Ì‹Ì·
∆¯ÓÈÎÒÓ ÀËÚÂÛÈÒÓ Ù˘ ÂÙ·ÈÚ›·˜ Ì·˜ (Î·È ÂÎÙfi˜
∏ӈ̤ÓÔ˘ µ·ÛÈÏ›Ԣ ÙÔÓ ÙÔÈÎfi ‰È·ÓÔ̤· Ù˘ Xpelair).
∞Ó ÚfiÎÂÈÙ·È ÁÈ· ÂÁηٿÛÙ·ÛË Û ÓÙÔ˘˜ ‹ Ì¿ÓÈÔ, Ô
Ú˘ıÌÈÛÙ‹˜ Î·È Ô ‰È·ÎfiÙ˘ ·ÔÌfiÓˆÛ˘ Ú¤ÂÈ Ó·
‚Ú›ÛÎÔÓÙ·È Î¿Ô˘ Ô˘ Ó· ÌË ÌÔÚÔ‡Ó Ó· Ù· ÊÙ¿ÛÔ˘Ó ÔÈ
¯ÚËÛÈÌÔÔÈÔ‡ÓÙ˜ ÙÔ ÓÙÔ˘˜ ÙÔ Ì¿ÓÈÔ.
°È· ÙÔ˘˜ ÛÎÔÔ‡˜ ÙˆÓ Ô‰ËÁÈÒÓ ·˘ÙÒÓ, ÔÈ ÙÚ¤¯Ô˘Û˜ Î·È ÔÈ
ÚÔËÁÔ‡ÌÂÓ˜ ÂΉfiÛÂȘ ÙˆÓ ÂÍ·ÂÚÈÛÙ‹ÚˆÓ ·Ó·ÁÓˆÚ›˙ÔÓÙ·È
Û·Ó «∆‡Ô˜ ∞» Î·È «∆‡Ô˜ µ» ˆ˜ ÂÍ‹˜:
∞Ó Ë Î·Ïˆ‰›ˆÛË Á›ÓÂÙ·È Û ˘¿Ú¯Ô˘Û·
ÂÁηٿÛÙ·ÛË, ·ÔÌÔÓÒÛÙ ÙËÓ ÎÂÓÙÚÈ΋ ·ÚÔ¯‹
Î·È ·Ê·ÈÚ¤ÛÙ ÙȘ ·ÓÙ›ÛÙÔȯ˜ ·ÛÊ¿ÏÂȘ ÚÈÓ
·fi οı ËÏÂÎÙÚÈ΋ ‰È·‰Èηۛ·.
∫·Ïˆ‰›ˆÛË Û ÂÍ·ÂÚÈÛÙ‹Ú˜ ∆‡Ô˘
∆ÔÔıÂÙÂ›Ù·È ¤Ó·˜ Û‡Ó‰ÂÛÌÔ˜ ÌÂٷ͇ ÙˆÓ ·ÎÚÔ‰ÂÎÙÒÓ 2 Î·È 3
ÛÙËÓ Ú›˙· ÙÔ˘ ÂÍ·ÂÚÈÛÙ‹Ú·. ∞ÏÏ¿ Ú¤ÂÈ Ó· ·Ê·ÈÚÂı› ÚÈÓ
ÙË Û‡Ó‰ÂÛË ÙÔ˘ Ú˘ıÌÈÛÙ‹. ∞Ó ‰ÂÓ ·Ê·ÈÚÂı›, Ô Ú˘ıÌÈÛÙ‹˜ ı·
˘ÔÛÙ› ÌfiÓÈÌË ‚Ï¿‚Ë.
∫·Ïˆ‰›ˆÛË Û ÂÍ·ÂÚÈÛÙ‹Ú˜ ∆‡Ô˘ µ
¢ÂÓ ˘¿Ú¯ÂÈ Î·Ïˆ‰È·Îfi˜ Û‡Ó‰ÂÛÌÔ˜ ÁÈ· ·Ê·›ÚÂÛË.
∞Ó Ô ÂÍ·ÂÚÈÛÙ‹Ú·˜ Â›Ó·È ‹‰Ë ÂÁηÙÂÛÙË̤ÓÔ˜
1 µÂ‚·Èˆı›Ù fiÙÈ Ë ËÏÂÎÙÚÈ΋ ·ÚÔ¯‹ Â›Ó·È ·ÔÌÔӈ̤ÓË.
2 ∞Ê·ÈÚ¤ÛÙ ÙȘ Û˘Ó‰¤ÛÂȘ Ù˘ ËÏÂÎÙÚÈ΋˜ ·ÚÔ¯‹˜ ·fi
ÙËÓ ÙÂÚÌ·ÙÈ΋ Ú›˙· ·fi ÙÔ ÙÂÚÌ·ÙÈÎfi ÌÏÔÎ.
3 ∞Ê·ÈÚ¤ÛÙ ÙËÓ ˘¿Ú¯Ô˘Û· ηψ‰›ˆÛË Î·È ·ÛÊ·Ï›ÛÙ ÙËÓ.
∞Ó Ô ÂÍ·ÂÚÈÛÙ‹Ú·˜ ‰ÂÓ ¤¯ÂÈ ·ÎfiÌ· ÂÁηٷÛÙ·ı›
1 µÂ‚·Èˆı›Ù fiÙÈ Ë ËÏÂÎÙÚÈ΋ ‰È·‚¿ıÌÈÛË ÙÔ˘ ÂÍ·ÂÚÈÛÙ‹Ú·
Â›Ó·È Û‡ÌʈÓË Ì ÙËÓ ËÏÂÎÙÚÈ΋ ·ÚÔ¯‹.
1 ¶ÂÚ¿ÛÙ ÙÔ Î·ÏÒ‰ÈÔ 5 ˘Ú‹ÓˆÓ ·fi ÙÔÓ ÂÍ·ÂÚÈÛÙ‹Ú·
ÛÙË ı¤ÛË ÙÔ˘ Ú˘ıÌÈÛÙ‹.
2 ∫·Ïˆ‰ÈÒÛÙ ÙË ÌÈ· ¿ÎÚË ÙÔ˘ ηψ‰›Ô˘ ÛÙȘ Û˘Ó‰¤ÛÂȘ
ÙÔ˘ ÂÍ·ÂÚÈÛÙ‹Ú· fiˆ˜ ÂÎÙ›ıÂÙ·È ÈÔ Î¿Ùˆ:
3 ∞Ê‹ÛÙ ÙËÓ ¿ÏÏË ¿ÎÚË ¤ÙÔÈÌË ÁÈ· Û‡Ó‰ÂÛË ÛÙÔÓ
Ú˘ıÌÈÛÙ‹.
√‰ËÁ›Â˜ ∂ÁηٿÛÙ·Û˘ Î·È §ÂÈÙÔ˘ÚÁ›·˜ ÙÔ˘ ƒ˘ıÌÈÛÙ‹
∂Í·ÂÚÈÛÙ‹Ú· FR22/30
√È Ô‰ËÁ›Â˜ ·˘Ù¤˜ Â›Ó·È ÌfiÓÔ ÁÈ· ÙËÓ ÂÁηٿÛÙ·ÛË Î·È ÙË ÏÂÈÙÔ˘ÚÁ›· ÙÔ˘ ƒ˘ıÌÈÛÙ‹ ∂Í·ÂÚÈÛÙ‹Ú·
FR22/30. °È· √‰ËÁ›Â˜ ∂ÁηٿÛÙ·Û˘ Î·È §ÂÈÙÔ˘ÚÁ›·˜ ∂Í·ÂÚÈÛÙ‹Ú· Û˘Ì‚Ô˘Ï¢ı›Ù ÙȘ Ô‰ËÁ›Â˜ Ô˘
Û˘ÓÔ‰Â‡Ô˘Ó ÙÔÓ Î¿ı ÂÍ·ÂÚÈÛÙ‹Ú·.
°ÂÓÈΤ˜ ÏËÚÔÊÔڛ˜
¶ÂÚÈÁÚ·Ê‹
∂ÁηٿÛÙ·ÛË ÙÔ˘ Ú˘ıÌÈÛÙ
∆È ı· ¯ÚÂÈ·ÛÙ› ÁÈ· ÙËÓ ÂÁηٿÛÙ·ÛË
¶Ô‡ ÙÔÔıÂÙÂ›Ù·È Ô Ú˘ıÌÈÛÙ‹˜
‰Ô˘ÏÂÈ¿ Û ۯ¤ÛË Ì ÙÔÓ ÂÍ·ÂÚÈÛÙ‹Ú·
∞Ó·ÁÓÒÚÈÛË ÙÔ˘ Ù‡Ô˘ ÙÔ˘ ÂÍ·ÂÚÈÛÙ‹Ú·
∆‡Ô˜ ∞1 ∆‡Ô˜ ∞2
∆‡Ô˜ B1 ∆‡Ô˜ B2
¶ÚÔÂÙÔÈÌ·Û›· ÙÔ˘ ÂÍ·ÂÚÈÛÙ‹Ú·
∫·Ïˆ‰›ˆÛË ÙˆÓ ËÏÂÎÙÚÈÎÒÓ Û˘Ó‰¤ÛÂˆÓ ÙÔ˘ ÂÍ·ÂÚÈÛÙ‹Ú·
∆À¶√™ ∂•∞∂ƒπ™∆∏ƒ∞ ¢π∞°ƒ∞ªª∞
∆‡Ô˜ ∞1 F1
∆‡Ô˜ ∞2 F2
∆‡Ô˜ µ F3
¶›Ó·Î·˜ 1
GR
1 ∞ÔÛ˘Ó‰¤ÛÙ ÙËÓ ÚfiÛÔ„Ë ·fi ÙÔ Ï·›ÛÈÔ
ÂÁηٿÛÙ·Û˘ ·Ê·ÈÚÒÓÙ·˜ Ù· ηχÌÌ·Ù· ÙˆÓ ‚›‰ˆÓ ηÈ
ÙȘ ‰˘Ô ‚›‰Â˜ (µÏ¤ ™¯. & ‚).
2 ∞ÔÛ˘Ó‰¤ÛÙ ÙÔ Ï·›ÛÈÔ ÂÁηٿÛÙ·Û˘ ·fi ÙÔ ÎÈ‚ÒÙÈÔ
ÙÔ›¯Ô˘ ·Ê·ÈÚÒÓÙ·˜ ÙȘ ‰˘Ô ‚›‰Â˜ (‚Ϥ ™¯. 2Á).
3 ™ËÎÒÛÙ ÙÔ ÎÈ‚ÒÙÈÔ ÙÔ›¯Ô˘ ·fi ÙÔ Ï·ÛÙÈÎfi Ï·›ÛÈÔ.
4 ∂ϤÁÍÙ ·Ó Ë ËÏÂÎÙÚÈ΋ ‰È·‚¿ıÌÈÛË Ô˘ ÂÎÙ›ıÂÙ·È Ì¤Û·
ÛÙÔÓ Ú˘ıÌÈÛÙ‹ Â›Ó·È Û‡ÌʈÓË Ì ÙËÓ ËÏÂÎÙÚÈ΋ ·ÚÔ¯‹.
5 ∞ÔÛ˘Ó‰¤ÛÙ ÙÔ Î·ÏÒ‰ÈÔ Á›ˆÛ˘ ·fi ÙÔ ÎÈ‚ÒÙÈÔ ÙÔ›¯Ô˘.
6 ∞ÓÔ›ÍÙ ÙÚ‡˜ ÂÈÛfi‰Ô˘ ηψ‰›ˆÓ ÛÙÔ Ï·ÛÙÈÎfi Î·È ÙÔ
ÌÂÙ·ÏÏÈÎfi ÎÈ‚ÒÙÈÔ ·Ê·ÈÚÒÓÙ·˜ Ù· ηٿÏÏËÏ· ÎÔ„›Ì·Ù·
(‚Ϥ ™¯. 1).
∫·Ù¿ ÙË ‰È¿ÚÎÂÈ· fiÏˆÓ ÙˆÓ ÂÚÁ·ÛÈÒÓ
ÙÚ˘·Ó›ÛÌ·ÙÔ˜ Î·È ÛÌÈχ̷ÙÔ˜ Ú¤ÂÈ Ó·
ÊÔÚ¿ÙÂ ÚÔÛÙ·Û›· Ì·ÙÈÒÓ.
µÂ‚·Èˆı›Ù fiÙÈ ‰ÂÓ ˘¿Ú¯Ô˘Ó ÛÙÔÓ ÙÔ›¯Ô
Î·Ï˘Ì̤ÓÔÈ ÛˆÏ‹Ó˜ ‹ ηÏ҉ȷ ÂÌfi‰È· ÛÙÔ
Â͈ÙÂÚÈÎfi .¯. ËÏÂÎÙÚÈÛÌfi˜, Áο˙È, ÓÂÚfi.
∞Ó ÙÔÔıÂÙÂ›Ù·È ÛÙËÓ ÂÈÊ¿ÓÂÈ·
1 ∂ÈÛ¿ÁÂÙ ηٿÏÏËÏÔ˘˜ Û˘Ó‰ÂÙÈÎÔ‡˜ ‰·ÎÙ˘Ï›Ô˘˜ ÛÙȘ
ÙÚ‡˜.
2 ∆ÚÔÊÔ‰ÔÙ‹ÛÙÂ Î·È Ù· ‰˘Ô ηÏ҉ȷ ̤۷ ·fi ÙÔ˘˜
Û˘Ó‰ÂÙÈÎÔ‡˜ ‰·ÎÙ˘Ï›Ô˘˜.
3 ∆ÔÔıÂÙ‹ÛÙ ÙÔ ÎÈ‚ÒÙÈÔ ÙÔ›¯Ô˘ Î·È ÙÔ Ï·ÛÙÈÎfi Ï·›ÛÈÔ
ÛÙÔÓ ÙÔ›¯Ô, ¯ÚËÛÈÌÔÔÈÒÓÙ·˜ ÙȘ ˘¿Ú¯Ô˘Û˜ ÙÚ‡˜
ÙÔÔı¤ÙËÛ˘.
4 ∂·Ó·Û˘Ó‰¤ÛÙ ÙÔ Î·ÏÒ‰ÈÔ Á›ˆÛ˘ ÛÙÔ ÎÈ‚ÒÙÈÔ ÙÔ›¯Ô˘.
∞Ó ÙÔÔıÂÙÂ›Ù·È Û ÂÛÔ¯‹
1 ∞ÓÔ›ÍÙ ÌÈ· ÙÚ‡· ÛÙÔÓ ÙÔ›¯Ô ·ÚÎÂÙ¿ ÌÂÁ¿ÏË ÁÈ· Ó·
¯ˆÚ¤ÛÂÈ ÙÔ ÎÈ‚ÒÙÈÔ ÙÔ›¯Ô˘. ∞Ê·ÈÚ¤ÛÙ ÙÔ Ï·ÛÙÈÎfi
Ï·›ÛÈÔ.
2 ∂ÈÛ¿ÁÂÙ ηٿÏÏËÏÔ˘˜ Û˘Ó‰ÂÙÈÎÔ‡˜ ‰·ÎÙ˘Ï›Ô˘˜ ÛÙȘ
ÙÚ‡˜.
3 ∆ÚÔÊÔ‰ÔÙ‹ÛÙÂ Î·È Ù· ‰˘Ô ηÏ҉ȷ ̤۷ ·fi ÙÔ˘˜
Û˘Ó‰ÂÙÈÎÔ‡˜ ‰·ÎÙ˘Ï›Ô˘˜.
4 ∆ÔÔıÂÙ‹ÛÙ ÙÔ ÎÈ‚ÒÙÈÔ ÙÔ›¯Ô˘ ÛÙÔÓ ÙÔ›¯Ô. µÂ‚·Èˆı›ÙÂ
fiÙÈ Ë ÊÏ¿ÓÙ˙· ÙÔ˘ Ï·ÈÛ›Ô˘ ÂÁηٿÛÙ·Û˘ ÂÊ·ÚÌfi˙ÂÈ
·ÎÚÈ‚Ò˜ ÛÙËÓ ÙÂÏÂȈ̤ÓË ÂÈÊ¿ÓÂÈ· ÙÔ˘ ÙÔ›¯Ô˘ (‚ϤÂ
‰È¿ÁÚ·ÌÌ· F6).
5 ∂·Ó·Û˘Ó‰¤ÛÙ ÙÔ Î·ÏÒ‰ÈÔ Á›ˆÛ˘ ÛÙÔ ÎÈ‚ÒÙÈÔ ÙÔ›¯Ô˘.
1 ∆ÔÔıÂÙ‹ÛÙ ÙÔÓ ‰È·ÎfiÙË ·ÔÌfiÓˆÛ˘ Û‡Ìʈӷ Ì ÙȘ
Ô‰ËÁ›Â˜ ÙÔ˘ ηٷÛ΢·ÛÙ‹.
2 ∫·Ïˆ‰ÈÒÛÙ ÙÔÓ Ú˘ıÌÈÛÙ‹ ÛÙÔÓ ‰È·ÎfiÙË ·ÔÌfiÓˆÛ˘
Î·È ÛÙÔÓ ÂÍ·ÂÚÈÛÙ‹Ú· fiˆ˜ Ê·›ÓÂÙ·È ÛÙÔ Î·Ù¿ÏÏËÏÔ
‰È¿ÁÚ·ÌÌ· (‚Ϥ ¶›Ó·Î· 1).
3 ∂·Ó·ÙÔÔıÂÙ‹ÛÙ ÙÔ Ï·›ÛÈÔ ÂÁηٿÛÙ·Û˘ ÛÙÔ
ÌÂÙ·ÏÏÈÎfi ÎÈ‚ÒÙÈÔ ÙÔ›¯Ô˘.
4 ∂·Ó·ÙÔÔıÂÙ‹ÛÙ ÙËÓ ÚfiÛÔ„Ë ÛÙÔ Ï·›ÛÈÔ
ÂÁηٿÛÙ·Û˘.
5 ∂·Ó·ÙÔÔıÂÙ‹ÛÙ ٷ ηχÌÌ·Ù· ÙˆÓ ‚›‰ˆÓ.
1 µÂ‚·Èˆı›Ù fiÙÈ Ë ËÏÂÎÙÚÈ΋ ·ÚÔ¯‹ Â›Ó·È ÎÏÂÈÛÙ‹ Î·È ÔÈ
·ÛÊ¿ÏÂȘ ¤¯Ô˘Ó ·Ê·ÈÚÂı›.
2 ¶ÂÚ¿ÛÙ ÙÔ Î·ÏÒ‰ÈÔ ·fi ÙÔÓ ‰È·ÎfiÙË ·ÔÌfiÓˆÛ˘ ÛÙÔ
ÛËÌÂ›Ô Û‡Ó‰ÂÛ˘ ÛÙËÓ ËÏÂÎÙÚÈ΋ ·ÚÔ¯‹.
3 ∫¿ÓÂÙ fiϘ ÙȘ Û˘Ó‰¤ÛÂȘ ̤۷ ÛÙÔÓ ‰È·ÎfiÙË
·ÔÌfiÓˆÛ˘ Û‡Ìʈӷ Ì ÙȘ Ô‰ËÁ›Â˜ ÙÔ˘ ηٷÛ΢·ÛÙ‹.
4 ∞ÎÔÏÔ˘ıÒÓÙ·˜ fiÏÔ˘˜ ÙÔ˘˜ ÙÔÈÎÔ‡˜ ηÓÔÓÈÛÌÔ‡˜
οÓÂÙ ÙË Û‡Ó‰ÂÛË ÛÙÔ ÛËÌÂ›Ô Ù˘ ËÏÂÎÙÚÈ΋˜ ·ÚÔ¯‹˜.
5 ∫¿ÓÂÙ ¤Ó·Ó ÙÂÏÈÎfi ¤ÏÂÁ¯Ô ÁÈ· Ó· ‚‚·Èˆı›Ù fiÙÈ fiÏ· Ù·
ÛËÌ›· Á›ˆÛ˘ Â›Ó·È Û˘Ó‰Â‰Â̤ӷ Î·È fiÏ· Ù· ηχÌÌ·Ù·
¤¯Ô˘Ó Â·Ó·ÙÔÔıÂÙËı› ÛˆÛÙ¿ ÛÙÔÓ ÂÍ·ÂÚÈÛÙ‹Ú·, ÙÔÓ
Ú˘ıÌÈÛÙ‹ Î·È ÙÔÓ ‰È·ÎfiÙË ·ÔÌfiÓˆÛ˘.
6 ∂·Ó·ÙÔÔıÂÙ‹ÛÙ fiϘ ÙȘ ·ÛÊ¿ÏÂȘ Î·È ·ÓÔ›ÍÙ ÙÔÓ
‰È·ÎfiÙË Ù˘ ËÏÂÎÙÚÈ΋˜ ·ÚÔ¯‹˜.
°È· ΢ÎÏÒÌ·Ù· ÛÙ·ıÂÚ‹˜ ηψ‰›ˆÛ˘, Ë ·ÛÊ¿ÏÂÈ· Ù˘
Û˘Û΢‹˜ ‰ÂÓ Ú¤ÂÈ Ó· ˘ÂÚ‚·›ÓÂÈ Ù· 5 ·Ì¤Ú.
°È· ÙËÓ ∞˘ÛÙÚ·Ï›· ÌfiÓÔ:
∆· ÌÔÓ٤Ϸ ·˘Ù¿ Â›Ó·È ÌfiÓÈÌ· Û˘Ó‰Â‰Â̤ӷ ÛÙËÓ ·ÚÔ¯‹ Î·È Ë
ÏÂÈÙÔ˘ÚÁ›· ÙÔ˘˜ ÂϤÁ¯ÂÙ·È ·fi ·ÔÌ·ÎÚ˘Ṳ̂ÓÔ ‰È·ÎfiÙË.
¶Ú¤ÂÈ Ó· ηψ‰ÈÒÓÔÓÙ·È ¿ÌÂÛ· ÛÙËÓ ·ÚÔ¯‹ ̤ۈ
ÂÁÎÂÎÚÈ̤ÓÔ˘ ‰È·ÎfiÙË ÂÈÊ·Ó›·˜ ÙÔ›¯Ô˘ 10 ·Ì¤Ú, Ì ÎÂÓfi
ÌÂٷ͇ ÙˆÓ Â·ÊÒÓ ÙÔ˘Ï¿¯ÈÛÙÔ 3 ¯ÛÙ.
∆ÔÔı¤ÙËÛË ÙÔ˘ Ú˘ıÌÈÛÙ‹
∞Ê·ÈÚ¤ÛÙ ÙÔ Î¿Ï˘ÌÌ· Î·È ÙÔ Ï·›ÛÈÔ ÂÁηٿÛÙ·Û˘
∆ÔÔı¤ÙËÛË ÙÔ˘ ÎÈ‚ˆÙ›Ô˘ ÙÔ›¯Ô˘
∫·Ïˆ‰›ˆÛË ÙÔ˘ ËÏÂÎÙÚÈÎÒÓ Û˘Ó‰¤ÛÂˆÓ ÙÔ˘ Ú˘ıÌÈÛÙ‹
™‡Ó‰ÂÛË ÛÙËÓ ËÏÂÎÙÚÈ΋ ·ÚÔ¯
™¯. 1: £¤ÛÂȘ Û˘Ó‰ÂÙÈÎÒÓ ‰·ÎÙ˘Ï›ˆÓ ηψ‰›Ô˘ ™¯. 2·: ∞Ê·›ÚÂÛË Î·Ï˘ÌÌ¿ÙˆÓ ‚›‰ˆÓ ™¯. 2‚: ∞Ê·›ÚÂÛË Ù˘ ÚfiÛԄ˘ ™¯. 2Á: ∞Ê·›ÚÂÛË ÙÔ˘ Ï·ÈÛ›Ô˘ ÂÁηٿÛÙ·Û˘
Ú˘ıÌÈÛÙ‹˜ ¤¯ÂÈ Ù· ÈÔ Î¿Ùˆ ¯·Ú·ÎÙËÚÈÛÙÈο:
(™˘Ì‚Ô˘Ï¢ı›Ù ٷ ‰È·ÁÚ¿ÌÌ·Ù· F1-F4).
1 ¶ÚÈÓ ÙÔ Î·ı¿ÚÈÛÌ· ·ÔÌÔÓÒÓÂÙ ÙÔÓ Ú˘ıÌÈÛÙ‹ ÙÂÏ›ˆ˜
·fi ÙËÓ ËÏÂÎÙÚÈ΋ ·ÚÔ¯‹.
2 ™ÊÔÁÁ›ÛÙ ÚÔÛÂÎÙÈο ÙÔ Î¿Ï˘ÌÌ· Ì ¤Ó· ˘ÁÚfi ·Ó›.
3 ™ÙÂÁÓÒÛÙ ÙÔ Î·Ï¿.
4 ºÚÔÓÙ›˙ÂÙ ÔÈ Û¯ÈṲ̂˜ ÂÍ·ÂÚÈÛÌÔ‡ Ó· ÌËÓ Â›Ó·È ÔÙ¤
‚Ô˘ÏˆÌ¤Ó˜.
ªË ‚˘ı›˙ÂÙ ÔÙ¤ ÙÔÓ Ú˘ıÌÈÛÙ‹ ÛÙÔ ÓÂÚfi ‹ ÛÂ
¿ÏÏ· ˘ÁÚ¿.
ªË ¯ÚËÛÈÌÔÔț٠ÔÙ¤ ‰È·Ï˘ÙÈο ÁÈ· Ó·
ηı·Ú›ÛÂÙ ÙÔÓ Ú˘ıÌÈÛÙ‹.
∂ÎÙfi˜ ·fi ÙÔ Î·ı¿ÚÈÛÌ·, ηÌÌ›· ¿ÏÏË
Û˘ÓÙ‹ÚËÛË ‰ÂÓ ¯ÚÂÈ¿˙ÂÙ·È.
¯Ú‹ÛË ÙÔ˘ Ú˘ıÌÈÛÙ‹ Û·˜
ÏÂÈÙÔ˘ÚÁ›· ÙÔ˘ Ú˘ıÌÈÛÙ‹
¶ÂÚÈÔ›ËÛË ÙÔ˘ Ú˘ıÌÈÛÙ‹
∫·ı¿ÚÈÛÌ·
1 ¢È·ÎfiÙ˘ On/Off
2 ¢È·ÎfiÙ˘
∂ÈÛ·ÁˆÁ‹˜/∂Í·ÁˆÁ‹˜
3 æËÏ‹/¯·ÌËÏ‹ Ù·¯‡ÙËÙ·
4 ºˆ˜ ÂӉ›ÎÙË
5 ™¯ÈṲ̂˜ ÂÍ·ÂÚÈÛÌÔ‡
6 ∫¿Ï˘ÌÌ· ‚›‰·˜
7 ¶ÚfiÛÔ„Ë
8 ¶Ï·›ÛÈÔ ÂÁηٿÛÙ·Û˘
9 ∫È‚ÒÙÈÔ ÙÔ›¯Ô˘
10 ¶Ï·ÛÙÈÎfi Ï·›ÛÈÔ
11 ∆ÂÚÌ·ÙÈÎfi ÌÏÔÎ Ú˘ıÌÈÛÙ‹
12 ∆ÂÚÌ·ÙÈÎfi ÌÏÔÎ ÂÍ·ÂÚÈÛÙ‹Ú·
13 ¢ÈÔÏÈÎfi˜ ‰È·ÎfiÙ˘
·ÔÌfiÓˆÛ˘
14 ∞ÛÊ¿ÏÂȘ
Do’s
Do - Read all the instructions before commencing installation.
Do - Install each fan with a double pole isolation switch.
Do- Make sure that the mains supply is switched off before attempting to make electrical
connections or carry out maintenance or cleaning.
Guarantee
Customers outside UK - see International below.
UK: The fan is guaranteed against defects for 3 years from the date of purchase.
Xpelair reserve the right to repair or replace at their option.
Please keep your purchase receipt.
If you have any problems, contact Xpelair’s Head Office at the address shown below.
Technical advice and service
Customers outside UK - see International below.
UK: Xpelair have a comprehensive range of services including:
Free technical advice help-desk from Engineers on all aspects of ventilation.
Free design service, quotations and site surveys.
Service and maintenance contracts to suit all requirements.
Please ask for details:
By telephone on Techline: +44 (0)8709 000430
By fax on Techfax: +44 (0)8709 000530
At the address below.
Head Office, UK Sales Office and Spares
Applied Energy Products Ltd, Morley Way, Peterborough PE2 9JJ England.
Telephone: +44 (0)1733 456789
Fax: +44 (0)1733 310606
Sales/Spares Hotline: +44 (0)8709 000420
Sales/Spares Faxline: +44 (0)8709 000520
http://www.xpelair.co.uk
International
Guarantee: Contact your local distributor or Xpelair direct for details.
Technical Advice and Service: Contact your local Xpelair distributor.
Part No. 567 2054 01
(Issue E)
BS EN ISO 9001
FM 02118
QAS 3284/37

Documenttranscriptie

GB GB NL F DA FR22-30 FAN CONTROLLER A NL F D II GR Installation and Operating Instructions PLEASE NOTE: THE CANADIAN (CSA) VERSION OF THIS FAN IS RATED AT 95W THIS IS FOR CONNECTION TO TYPE B1 AND B2 FANS ONLY. SEE "IDENTIFYING FAN TYPE" SECTION. F1 N L L N 13 14 12 E N NF 3 1 3 2 1 L N E 11 2 11 13 12 E N L 1 2 3 N L 14 N L E N 14 L3 2 1 E N L 1 2 3 12 N L3 2 1 NF NF F2 11 13 F3 F4 F6 10 9 8 7 6 5 4 1 2 3 210mm 45mm I High 0 86mm Low 210mm 41mm 81mm 0 86mm 182mm 208mm Low I High 86mm F5 FR22/30 Fan Controller Installation and Operating Instructions These Instructions are for the Installation and Operation of the FR22/30 Fan Controller only. For Fan Installation and Operating Instructions refer to literature provided with the appropriate fan. General Information Working with the Fan Description Identifying Fan Type This appliance is designed to control the operation of Xpelair fans of the GX9, GX12, WX9, WX12, RX9 & RX12 ranges (wall & window mounted). The controller may be either surface mounted, or recess mounted within it’s own patress box. You may only wire one fan to each controller. For the purpose of these instructions current and previous versions of the fans are identified into Type A & Type B, as follows: Installing the Controller These installation instructions are for the installation of the controller when used in combination with Xpelair supplied fans. Type A1 Type A2 Type B1 Type B2 The controller must be installed to fixed wiring. Ensure the Main Electrical Supply matches the rating shown on the controller casing. This appliance must be earthed. All installation must be supervised by a qualified electrician. Installation and wiring must conform to current IEE wiring regulations (UK), or local appropriate regulations (other countries). If you have any queries either before, during and after the installation of the controller, please do not hesitate to contact the UK Xpelair hotline (number on back page). Customers outside the UK: contact your local Xpelair distributor. What the installer will need ♦ A double pole isolating switch with a minimum contact gap of 3mm (Wall or Ceiling mounted). ♦ Suitably rated 5-core cable to connect the controller to the fan. If the fan is window mounted, use flexible cable (Available from Xpelair). ♦ Suitably rated 3-core cable to connect the controller to the Main Electrical Supply. If using flexible cable, suitable glands incorporating cable clamps must be fitted to the knockouts in the Controller Box. (Refer to Fig. 1). Location of the Controller ♦ Not where ambient temperatures are likely to exceed 50°C. ♦ If installed in a kitchen the Controller must not be mounted immediately above a cooker hood or eye level grill. ♦ When intended for use in possible chemical corrosive atmospheres, consult our Technical Service Department (Outside the UK contact your local Xpelair distributor). ♦ If installed in a shower room or bathroom the controller and isolating switch must be situated so that they cannot be touched by persons making use of the bath or shower. Preparing the Fan If wiring to an existing installation isolate mains supply and remove applicable fuses prior to any electrical procedure. If wiring to Type A fans A link is fitted between terminals 2 and 3 in the fan socket, this must be removed before connecting the Controller. If you do not remove it, the Controller will be permanently damaged. If wiring to Type B fans There is no wire link to be removed. If the fan is already installed 1 Ensure the power supply is isolated. 2 Disconnect the mains connections from the fan’s terminal socket or from the terminal block. 3 Remove the existing wiring and make it safe. If the fan is not yet installed. 1 Check that the fan electrical rating matches the power supply. Wire the fan electrical connections 1 Route the 5-core cable from the Fan to the Controller position. 2 Wire one end of the cable into the fan connections as shown thus: FAN TYPE DIAGRAM F1 Type A1 F2 Type A2 F3 Type B Table 1. 3 Leave the other end ready to be connected to the Controller. Mounting the Controller Remove the Cover and Mounting Frame Wire the Controller electrical connections 1 Detach the Fascia from the Mounting Frame by removing the screw covers and two screws (Refer to Fig. 2a&b). 2 Detach the Mounting Frame from the Wall Box by removing the two screws (Refer to Fig. 2c). 3 Lift the Wall Box away from the Plastic Surround. 4 Check that the electrical rating shown inside the controller matches the power supply. 5 Disconnect the earth wire from the Wall Box. 6 Make cable entry holes in the plastic and metal boxes by removing suitable knockouts (Refer to Fig. 1). 1 Mount the Isolation Switch in accordance with the manufacturers instructions. 2 Wire the Controller to the Isolation Switch and to the Fan as shown in the appropriate diagram (Refer to Table 1). 3 Refit Mounting Frame to Metal Wall Box. 4 Refit the Fascia to the Mounting Frame. 5 Refit the Screw Covers. Mounting the Wall Box Eye protection must be worn during all drilling & chiselling operations. Check there are no buried Pipes or Cables in the wall or obstructions on the outside e.g. Electricity, Gas, Water. If surface mounting 1 Insert suitable glands into the knockouts. 2 Feed both cables through the glands. 3 Fix the Wall Box and Plastic Surround to the wall, using the mounting holes provided. 4 Reconnect the earth lead to the Wall Box. If recess mounting 1 Make a hole in the wall big enough to take the Wall Box. Discard the Plastic Surround. 2 Insert suitable glands into the knockouts. 3 Feed both cables through these glands. 4 Fix the Wall Box to the wall. Ensure that the flange of the mounting frame fits flush to the finished surface of the wall (Refer diagram F6). 5 Reconnect the earth lead to the Wall Box. Fig. 1 : Cable Gland Positions Fig. 2a : Removing screw covers Using your Controller Connect to Power Supply 1 Ensure power supply is isolated and fuses are removed. 2 Route the Cable from the Isolating Switch to the point of connection to the power supply. 3 Make all connections within the Isolating Switch in accordance with the manufacturers instructions. 4 Following all local regulations make connection at point of power supply. 5 Make a final check to ensure all earth points are connected and all covers have been correctly replaced on the fan, controller and isolating switch. 6 Replace all fuses, and switch on the power supply. For fixed wiring circuits the protective fuse for the appliance must not exceed 5 amps. For Australia only: These models are permanently connected to the supply & operation is controlled by a remote switch. They should be directly wired to the supply through an approved 10 amp wall mounted surface switch with at least 3mm clearance between contacts. Fig. 2b:Removing fascia Looking after the Controller Operating the Controller The Controller has the following features: (Refer to diagrams F1-F4). 1 On / Off switch 2 Intake / Extract switch 3 High / Low speed 4 5 6 7 Indicator light Ventilation slots Screw cover Fascia 8 Mounting Frame 9 Wall Box 10 Plastic Surround 11 Controllers Terminal Block 12 Fan’s Terminal Block 13 Double Pole Isolator switch 14 Fuses Fig. 2c: Removing mounting frame Cleaning 1 Before cleaning isolate the Controller completely from the power supply. 2 Wipe the Cover carefully with a damp cloth. 3 Dry thoroughly. 4 Ensure ventilation slots are free from obstuctions at all times. ♦ ♦ ♦ Never immerse the Controller in water or other liquids. Never use solvents to clean the Controller. Apart from cleaning, no other maintenance is required. Installatie- en bedieningsvoorschriften voor de regeleenheid van de FR22/30 Ventilator NL Deze voorschriften zijn uitsluitend bestemd voor de installatie en bediening van de FR22/30 ventilator-regeleenheid. Voor de Installatie- en bedieningsvoorschriften van de ventilator gelieve u de met de betreffende ventilator meegeleverde literatuur te raadplegen. Algemene informatie Werken met de ventilator Beschrijving Identificeren van het type ventilator Dit apparaat is bedoeld om de bediening te besturen van de Xpelair ventilatoren type GX9, GX12, WX9, WX12, RX9 & RX12 (wand- of raammontage). De regelaar kan of op een oppervlak worden gemonteerd, of in een uitsparing voor zijn eigen gegalvaniseerd metalen inbouwdoos. U mag enkel één ventilator aan elke regelaar aansluiten. Ten behoeve van deze voorschriften worden de huidige en vroegere versies ventilatoren geïdentificeerd als Type A & Type B, zie hierna: Installeren van de regeleenheid Deze installatievoorschriften zijn bestemd voor de installatie van de besturingseenheid wanneer deze wordt gebruikt in combinatie met door Xpelair geleverde ventilatoren. Deze regelaar moet aan vaste bedrading worden aangebracht. Zorg ervoor dat de hoofdstroomtoevoer overeenkomt met de toelaatbare nominale waarde als afgebeeld op het huis van de regelaar. Denk eraan, dit apparaat moet geaard zijn. Alle installatiewerkzaamheden moeten worden verricht onder toezicht van een erkend elektricien. Installatie en aansluiting moeten worden uitgevoerd conform de huidige IEE reglementen (VK), of de lokaal van toepassing zijnde reglementen (andere landen). Wanneer u voor, tijdens of na de installatie van de regelaar nog vragen mocht hebben, aarzel dan niet contact op te nemen met de GB hotline (voor nummer zie laatste bladzijde). Klanten buiten GB wordt aangeraden contact op te nemen met hun plaatselijke Xpelair dealer. Nodig voor de installatie ♦ Een tweepolige schakelaar met een minimum contactafstand van 3 mm (muur- of plafondmontage). ♦ Passende 5-aderige kabel om de regelaar aan de ventilator aan te sluiten. Als de ventilator raam-gemonteerd wordt dan moet een flexibele kabel worden gebruiken. (Verkrijgbaar bij Xpelair). ♦ Passende 3-aderige kabel voor de aansluiting van de regelaar aan de hoofdstroomtoevoer. Wanneer flexibele kabel wordt gebruikt moeten passende doorvoeren worden aangebracht via de uitbreekplaatjes in de doos van de regelaar. (Zie Afb. 1.) Aanbrengen van de regeleenheid ♦ Deze niet aanbrengen waar de omgevingstemperaturen 50CN te boven gaan. ♦ Wanneer in een keuken aangebracht mag de regelaar niet direct boven een wasemkap of ooghoogte van de grill worden gemonteerd. ♦ Wanneer bestemd voor gebruik in mogelijk chemisch corrosieve atmosferen eerst onze Technische Service afdeling raadplegen. (Buiten GB: neem contact op met uw lokale Xpelair dealer). ♦ Wanneer gemonteerd in een douche- of badkamer dan moet de regelaar daar worden aangebracht waar zij niet kunnen worden aangeraakt door personen die de douche of het bad gebruiken. Type A1 Type A2 Type B1 Type B2 Preparatie van de ventilator Wanneer de ventilator aan een bestaande installatie wordt aangesloten moet eerst de stroomtoevoer worden geisoleerd en van toepassing zijnde zekeringen worden verwijderd en wel voordat aan gelijk welke elektrische procedure wordt begonnen. Bij aansluiting van Type A ventilatoren In de contactdoos van de ventilator is tussen klem 2 en 3 een verbindingsdraad aangebracht die moet worden verwijderd voordat de regelaar wordt aangesloten. Als u de verbindingsdraad niet verwijderd zal dit permanente beschadiging van de regelaar tot gevolg hebben. Bij aansluiting van Type B ventilatoren Hier hoeft geen verbindingsdraad te worden verwijderd. Als de ventilator reeds is geinstalleerd 1. Zorg ervoor dat de netvoeding is geisoleerd. 2. Maak de elektrische aansluitingen los van de klembus of van het klemmenblok van de ventilator. 3. Verwijder de bestaande bedrading en maak deze veilig. Als de ventilator nog niet is geinstalleerd 1 Controleer of de toelaatbare nominale waarde van de ventilator overeenkomt met de stroomtoevoer. Bedrading van de elektrische aansluitingen van de ventilator 1. Breng de 5-aderige kabel aan van de ventilator naar de regelaar. 2. Sluit één kant van de kabel aan in de aansluitingen van de ventilator, als hierna afgebeeld: TYPE VENTILATOR SCHAKELSCHEMA Type A1 Type A2 Type B F1 F2 F3 Tabel 1. 3. Maak de nadere kant klaar om aan de regelaar te worden aangesloten. Montage van de regeleenheid Verwijdering van de afdekkap en het montageframe Aansluiting van de elektrische verbindingen van de regeleenheid. 1. Maak het bedieningspaneel los van het montageframe door verwijdering van de schroefdoppen en twee schroeven. (Zie Afb. 2a & 2b.) 2. Maak het montageframe los van de wanddoos door verwijdering van de twee schroeven. (Zie Afb. 2c.) 3. Til de wanddoos uit de kunststof ombouw. 4. Controleer of de toelaatbare nominale waarde in de regelaar overeenkomt met de stroomtoevoer. 5. Maak de aardleiding los van de wanddoos. 6. Maak kabel-ingangsgaten in de kunststof en metalen dozen door verwijdering van de toepasselijke uitbreekplaatjes. (Zie Afb. 1.) 1. Monteer de scheidingsschakelaar conform de voorschriften van de fabrikant. 2. Sluit de regeleenheid aan naar de scheidingsschakelaar en naar de ventilator, als weergegeven in de betreffende tekening. (Zie tabel 1.) 3. Bevestig het montageframe weer aan de metalen wanddoos. 4. Bevestig het bedieningspaneel weer aan het montageframe. 5. Breng de schroefdoppen weer aan. Montage van de wanddoos Bij alle boor- en beitelwerkzaamheden moet oogbescherming worden gedragen. Controleer of er geen verborgen leidingen of kabels in de muur zitten, danwel of er zich obstructies aan de buitenkant van de muur bevinden, zoals elektriciteit, gas of water. Bij oppervlakte-montage 1. Breng passende kabeldoorvoeren in de uitbreekplaatjes aan. 2. Voer beide kabels in door de doorvoeren. 3. Monteer de wanddoos en kunststof ombouw aan de muur via de aangebrachte montagegaten. 4. Verbind de aardleiding weer aan de wanddoos. Montage in een uitsparing 1. Maak een gat in de muur dat groot genoeg is voor de wanddoos. Gooi de kunststof ombouw weg. 2. Breng passende kabeldoorvoeren in de uitbreekplaatjes aan. 3. Voer beide kabels in door de doorvoeren. 4. Monteer de wanddoos aan de muur. Zorg ervoor dat de flens van het montageframe gelijk is met het afgewerkte oppervlak van de muur. (Zie tekening F6.) 5. Verbind de aardleiding weer aan de wanddoos. Afb. 1: Plaatsen voor de drukringen Afb. 2a: Verwijderen van schroefdoppen Aansluiten aan de stroomtoevoer 1. Zorg ervoor dat de stroomtoevoer gescheiden is en de zekeringen zijn verwijderd. 2. Breng de kabel aan van de scheidingsschakelaar naar het aansluitpunt naar de stroomtoevoer. 3. Breng alle aansluitingen in de scheidingsschakelaar aan conform de voorschriften van de fabrikant. 4. Volg alle lokaal geldende voorschriften op voor het maken van een aansluiting bij het aansluitpunt voor de stroomtoevoer. 5. Voer een laatste controle uit om te verzekeren dat alle aardpunten zijn aangesloten en alle afdekkappen weer correct zijn aangebracht op de ventilator, regeleenheid en scheidingsschakelaar. 6. Breng alle zekeringen weer aan en schakel de stroomtoevoer aan. Voor vaste bedradingscircuits mag de beschermende zekering voor het apparaat 5 amp niet overschrijden. Enkel voor Australië: Aansluiting aan de stroomtoevoer kan worden gemaakt met een flexibele 3-aderige kabel compleet met een 3-polige steker voor invoer in een goedgekeurde 10 amp GPO, of kan direct worden aangesloten via een goedgekeurde 10 amp muurgemonteerde oppervlakteschakelaar met (ten minste) 3 mm afstand tussen de contacten. Afb. 2b: Verwijderen van bedieningspaneel Afb. 2c: Verwijderen van montageframe Het gebruik van uw regelaar Verzorging van de regelaar De bediening van de regelaar Schoonmaken De regelaar kan voor het volgende worden gebruikt: (Zie tekeningen F1 - F4.) 1. Aan/Uit schakelaar 2. Aanzuig/Afzuig schakelaar 3. Hoog/Laag toerental 4. Verklikkerlampje 5. Ventilatiegroeven 6. Schroefdop 7. Bedieningspaneel 8. Montageframe 9. Wanddoos 10.Kunststof ombouw 11.Klemmenblok regeleenheden 12.Klemmenblok ventilator 13.Dubbelpolig scheidingsschakelaar 14.Zekeringen 1. Voorafgaand aan reiniging de stroomtoevoer naar de regelaar geheel isoleren. 2. De afdekkap voorzichtig met een vochtige doek afnemen. 3. Goed afdrogen. 4. Houd de ventilatiegroeven vrij van obstructies. ♦ ♦ ♦ De regelaar nooit in water of andere vloeistoffen onderdompelen. Nooit oplosmiddelen gebruiken om regelaar schoon te maken. Naast schoonmaken is geen verder onderhoud nodig. D Installations- und Betriebsanleitung Ventilatorregler FR22/30 Die vorliegende Anleitung bezieht sich nur auf die Installation und den Betrieb des Ventilatorreglers FR22/30. Die Installations- und Betriebsanleitung für den Ventilator entnehmen Sie bitte dem mit dem betreffenden Ventilator mitgelieferten Informationsmaterial. Allgemeine Informationen Arbeiten am Ventilator Beschreibung Bestimmen des Ventilatortyps Dieses Gerät ist zum Regeln des Betriebs von XpelairVentilatoren der Baureihen GX9, GX12, WX9, WX12, RX9 und RX12 (wand- und fenstermontiert) bestimmt. Der Regler ist für Auf- und Unterputzinstallation geeignet (nur Großbritannien). Es darf nur maximal ein Ventilator pro Regler angeschlossen werden. Zum Zweck dieser Anleitung werden derzeitige und ältere Ventilatorversionen wie folgt entweder Typ A oder Typ B zugeordnet: Installation des Reglers Diese Installationsanleitung behandelt die Installation des Reglers bei Verwendung in Verbindung mit Ventilatoren von Xpelair. Der Regler muß an eine Festverdrahtung angeschlossen werden. Stellen Sie sicher, daß die auf dem Reglergehäuse angegebenen Nennwerte mit der Netzstromversorgung übereinstimmen. Dieses Gerät muß geerdet werden. Alle Installationsarbeiten dürfen nur von einer qualifizierten Elektrofachkraft ausgeführt werden. In Großbritannien sind Installation und Verdrahtung gemäß den derzeitig gültigen IEE-Bestimmungen auszuführen. In anderen Ländern sind die jeweils geltenden nationalen Vorschriften einzuhalten. Sollten Sie vor, bei oder nach der Installation des Reglers irgendwelche Fragen haben, wenden Sie sich bitte an die britische Xpelair-Hotline (Telefonnummer siehe Rückseite). Nicht in Großbritannien befindliche Kunden von Xpelair wenden sich an ihren örtlichen Xpelair-Händler. Was zur Installation benötigt wird ♦ Ein zweipoliger Netztrennschalter mit einer Kontaktöffnung von 3 mm (an Wand oder Decke montiert). ♦ Ausreichend dimensionierte fünfadrige Anschlußleitung zum Anschließen des Reglers an den Ventilator. Bei Fenstereinbau des Ventilators sollte eine flexible Anschlußleitung verwendet werden (bei Xpelair erhältlich). ♦ Ausreichend dimensionierte dreiadrige Anschlußleitung zwischen Ventilator und Netzstromversorgung. Falls eine flexible Anschlußleitung verwendet wird, muß für ausreichende Zugentlastung gesorgt werden (siehe Abb. 1). Installationsort des Reglers ♦ Der Regler darf nicht an Stellen installiert werden, an denen eine Umgebungstemperatur von +50°C überschritten werden könnte. ♦ Der Regler darf nicht in unmittelbarer Nähe von Herdplatten, Dunstabzugshauben oder anderen Wandöffnungen montiert werden. ♦ Falls der Ventilator zur Förderung möglicherweise chemisch korrodierender Atmosphäre vorgesehen ist, sollten Sie mit Ihrem örtlichen Xpelair-Händler Verbindung aufnehmen (Großbritannien: bitte wenden Sie sich an den Technischen Kundendienst von Xpelair). ♦ Beim Einbau in einem Badezimmer/Duschraum müssen Regler und Netztrennschalter gemäß den einschlägigen Bestimmungen und so positioniert werden, daß sie vom Bad/von der Dusche aus nicht berührt werden können. Typ A1 Typ A2 Typ B1 Typ B2 Vorbereitung des Ventilators Falls der Ventilator an eine existierende Anlage angeschlossen werden soll, ist für eine allpolige Netztrennung zu sorgen und die betreffenden Sicherungen sind zu entfernen, bevor mit Elektroarbeiten begonnen wird. Beim Anschließen an Ventilatoren des Typs A Die Brücke zwischen den Anschlußklemmen 2 und 3 in der Anschlußbuchse des Ventilators muß vor dem Anschließen des Reglers entfernt werden. Wird die Brücke nicht entfernt, kann das zu einer dauerhaften Beschädigung des Reglers führen. Beim Anschließen an Ventilatoren des Typs B Das Entfernen der Brücke ist hier nicht erforderlich. Falls der Ventilator bereits installiert ist 1 Stellen Sie sicher, daß eine allpolige Netztrennung gegeben ist. 2 Trennen Sie den Netzanschluß von der Steckbuchse bzw. vom Klemmenbrett. 3 Überprüfen Sie die vorhandene Verdrahtung auf elektrische Sicherheit. Falls der Ventilator noch nicht installiert ist: 1 Überprüfen Sie, ob die elektrischen Anschlußdaten des Ventilators mit denen der Netzstromversorgung übereinstimmen. Verdrahten der elektrischen Anschlüsse des Ventilators 1 Verlegen Sie das fünfadrige Kabel zwischen Ventilator und Regler. 2 Schließen Sie ein Ende des Kabels wie abgebildet an die Anschlüssen des Ventilators an: VENTILATORTYP ANSCHLUSSDIAGRAMM Typ A1 Typ A2 Typ B F1 F2 F3 Tabelle 1 3 Das andere Ende dient zum Anschluß an den Regler. Montage des Reglers Entfernen der Abdeckung und des Montagerahmens Elektrischer Anschluß des Reglers 1 Lösen Sie die Frontplatte vom Montagerahmen, indem Sie die Schraubenabdeckungen abnehmen und die zwei Schrauben entfernen (siehe Abb. 2a und 2b). 2 Lösen Sie den Montagerahmen vom Wandkasten durch Herausschrauben der zwei Schrauben (siehe Abb. 2c). 3 Ziehen Sie den Wandkasten von der Kunststoffeinfassung ab. 4 Überprüfen Sie, ob die elektrische Auslegung auf der Innenseite des Reglers mit der Stromversorgung übereinstimmt. 5 Klemmen Sie den Erdungsanschluß vom Wandkasten ab. 6 Öffnen Sie die Kabeleingangslöcher in den Kunststoff- und Metallkästen durch Ausbrechen der vorgesehenen Sollbruchstellen (siehe Abb. 1). 1 Montieren Sie den Netztrennschalter gemäß der Anleitung des Herstellers. 2 Schließen Sie den Regler in Übereinstimmung mit dem entsprechenden Diagramm an den Netztrennschalter und den Ventilator an (siehe Tabelle 1). 3 Bringen Sie den Montagerahmen wieder am Wandkasten (Metall) an. 4 Bringen Sie die Frontplatte wieder am Montagerahmen an. 5 Bringen Sie die Schraubenabdeckungen wieder an. Montage des Wandkastens 1 Stellen Sie sicher, daß eine allpolige Netztrennung gegeben ist und die Sicherungen entfernt werden. 2 Verlegen Sie das Kabel vom Netztrennschalter zum Netzstromversorgungsanschlußpunkt. 3 Stellen Sie in Übereinstimmung mit der Anleitung des Herstellers alle Anschlüsse im Netztrennschalter her. 4 Stellen Sie unter Einhaltung aller einschlägigen Vorschriften den Netzstromanschluß her. 5 Überprüfen Sie abschließend, daß alle Erdungspunkte angeschlossen sind und alle Abdeckungen an Ventilator, Regler und Netztrennschalter wieder richtig angebracht worden sind. 6 Setzen Sie alle Sicherungen wieder ein und schalten Sie die Netzstromversorgung ein. Während der gesamten Dauer der Bohr- und Meißelvorgänge muß ein Augenschutz getragen werden. Vergewissern Sie sich, daß sich an der gewünschten Montageposition keine eingelassenen Leitungen, wie z.B. Strom-, Gasoder Wasserleitungen, befinden, welche bei der Installation eventuell beschädigt werden könnten. Bei Aufputzmontage 1 Setzen Sie geeignete Kabelverschraubungen in die Ausbrüche ein. 2 Führen Sie beide Kabel durch diese Verschraubungen. 3 Befestigen Sie den Wandkasten und die Kunststoffeinfassung über die vorgesehenen Montagelöcher an der Wand. 4 Schließen Sie den Erdungsleiter wieder am Wandkasten an. Bei Unterputzeinbau 1 Fertigen Sie eine Vertiefung in der Wand zur Aufnahme des Wandkastens an. Die Kunststoffeinfassung wird für die Unterputzmontage nicht benötigt. 2 Setzen Sie geeignete Kabelverschraubungen in die Ausbrüche ein. 3 Führen Sie beide Kabel durch diese Verschraubungen. 4 Befestigen Sie den Wandkasten an der Wand. Achten Sie darauf, daß der Flansch des Montagerahmens an der fertigen Wandoberfläche bündig anliegt (siehe Diagramm F6). 5 Schließen Sie den Erdungsleiter wieder am Wandkasten an. Anschluß an die Stromversorgung (Großbritannien:) Bei Festverdrahtung darf die Schutzsicherung für das Gerät den Nennstrom von 5 A nicht überschreiten. Nur Australien: Diese Modelle sind permanent an die Stromversorgung angeschlossen und ihr Betrieb wird über einen separaten Schalter gesteuert. Sie sollten durch einen zugelassenen aufputzmontierten 10-A-Schalter mit einem Mindestabstand von 3 mm zwischen Kontakten direktverdrahtet sein. Abb.1 Abb.2a : Positionen der Kabelverschraubungen Abnehmen der Schraubenabdeckungen Abb.2c: Abnehmen des Montagerahmens Benutzung des Reglers Instandhaltung des Reglers Betrieb des Reglers Reinigung Der Regler besitzt folgende Funktionen (siehe Diagramme F1 - F4): 1 2 3 4 5 6 7 Abb.2b: Abnehmen der Frontplatte Ein/Aus-Schalter Zuluft/Abluft-Schalter Hohe/Niedrige Geschwindigkeit Betriebsleuchte Lüftungsschlitze Schraubenabdeckung Frontplatte 8 Montagerahmen 9 Wandkasten 10 Kunststoffeinfassung 11 Klemmenbrett des Reglers 12 Klemmenbrett des Ventilators 13 Zweipoliger Netztrennschalter 14 Sicherungen 1 2 3 4 Der Regler ist vor der Reinigung allpolig vom Netz zu trennen. Die Abdeckung sorgfältig mit einem feuchten Tuch abwischen. Gründlich abtrocknen. Stellen Sie sicher, daß die Lüftungsschlitze nie verdeckt oder verstopft werden. ♦ Der Regler darf auf keinen Fall in Wasser oder andere Flüssigkeiten eingetaucht werden. ♦ Den Regler niemals mit Lösungsmitteln reinigen. ♦ Abgesehen von der Reinigung ist keine weitere Wartung erforderlich. A F Instructions d’installation et d’utilisation du Contrôleur de ventilateur FR22/30 Ces instructions concernent uniquement l’installation et l’utilisation du contrôleur de ventilateur FR22/30. Pour les instructions sur l’installation et l’utilisation du ventilateur, référez-vous aux documents Informations Générales Utilisation du ventilateur Description Identification du type de ventilateur Cet appareil est conçu pour contrôler le fonctionnement des ventilateurs Xpelair des gammes GX9, GX12, WX9, WX12, RX9 et RX12 (montage mural et sur fenêtres). Le contrôleur peut être soit monté en saillie, soit encastré dans sa propre boîte. Vous ne devez pas relier plus d’un ventilateur à chaque contrôleur Pour les besoins de ces instructions, les versions actuelles et précédentes des ventilateurs sont identifiées en Type A & Type TypeB, B,comme comme suit: suit : Installation du contrôleur Ces instructions d’installation concernent l’installation du contrôleur lorsqu’il est utilisé avec des ventilateurs fournis par Xpelair. Le contrôleur doit être relié à un câblage fixe. Assurez-vous que l’alimentation secteur correspond aux caractéristiques indiquées sur le boîtier du contrôleur. Cet appareil doit être mis à la terre. Toutes les installations doivent être supervisées par un électricien qualifié. L’installat(ion et le câblage doivent être conformes aux règlements actuels IEE (R-U), ou aux règlements locaux appropriés (autres pays). Si vous avez des questions avant, pendant et après l’installation du contrôleur, n’hésitez pas à contacter le numéro britannique d’urgence de Xpelair (numéro sur la dernière page). Pour les clients hors du Royaume-Uni, contactez votre distributeur Xpelair local. Ce dont l’installateur a besoin ♦ Un interrupteur bipolaire de coupure avec intervalle de coupure minimal de 3 mm (Montage mural ou au plafond). ♦ Un câble à 5 conducteurs de caractéristiques adéquates pour relier le contrôleur au ventilateur. Si le ventilateur est monté sur une fenêtre, utilisez un câble souple. (Disponible chez Xpelair). ♦ Un câble à 3 conducteurs de caractéristiques adéquates pour relier le contrôleur à l’alimentation secteur. Si vous utilisez un câble flexible, des presseétoupe adéquats équipés de colliers de serrage doivent être montés sur les pastilles préformées de la boîte du contrôleur. (Voir Fig. 1). Emplacement du contrôleur ♦ Pas où les températures ambiantes peuvent dépasser 50°C. ♦ S’il est installé dans une cuisine, le contrôleur ne doit pas être monté directement au dessus d’une hotte de cuisinière ou d’un grill à hauteur d’oeil. ♦ S’il est destiné à être utilisé dans des atmosphères chimiques pouvant être corrosives, demandez conseil à notre Service Technique. (En dehors du Royaume-Uni, contactez votre distributeur Xpelair local). ♦ S’il est installé dans une salle de douche ou une salle de bain, le contrôleur et lecommutateur d’isolation doivent être placés de manière qu’ils ne puissent être touchés par les personnes utilisant le bain ou la douche. Type A1 Type A2 Type B1 Type B2 Préparation du ventilateur Dans le cas de câblage à une installation existante, isolez l’alimentation secteur et retirez les fusibles concernés avant toute procédure électrique Dans le cas de câblage à des ventilateurs de Type A Il y a un cavalier entre les bornes 2 et 3 dans la prise du ventilateur, et ce cavalier doit être retiré avant de relier le contrôleur. Si vous ne le retirez pas, le contrôleur sera définitivement endommagé. Dans le cas de câblage à des ventilateurs de Type B Il n’y a pas de cavalier à retirer. Si le ventilateur est déjà installé 1 Assurez-vous que l’alimentation secteur est coupée. 2 Débranchez les connexions du secteur de la prise à bornes du ventilateur ou du bornier. 3 Retirez les fils existants et mettez en sécurité. Si le ventilateur n’est pas encore installé 1 Vérifiez que les caractéristiques électriques du ventilateur correspondent à l’alimentation électrique. Câblage des connexions électriques du ventilateur 1 Faites passer le câble à 5 conducteurs du ventilateur au contrôleur 2 Reliez une extrémité du câble aux connexions du ventilateur comme indiqué ci-après : TYPE SCHEMA F1 Type A1 F2 Type A2 F3 Type B Tableau 1. 3 Laissez l’autre extrémité prête à être reliée au contrôleur Montage du contrôleur Retrait du couvercle et du cadre de montage Câblage des connexions électriques du contrôleur 1 Enlever l’avant du cadre de montage en retirant les couvercles de vis et les deux vis. (Voir la Fig. 2a&b). 2 Enlever le cadre de montage du boîtier mural en retirant les deux vis. (Voir la Fig. 2c). 3. Retirez le boîtier de la bordure en plastique. 4 Vérifiez que la puissance électrique indiquée à l’intérieur du contrôleur correspond à celle de l’alimentation principale. 5 Débranchez du boîtier mural le fil de mise à la terre. 6 Faites des trous d’entrée pour le câble dans les boîtiers en plastique et métalliques en retirant les pastilles préformées appropriées. (Voir la Fig. 1). 1 Montez le commutateur d’isolation conformément aux instructions des fabricants. 2 Câblez le contrôleur au commutateur d’isolation et au ventilateur comme illustré sur le schéma approprié. (Voir le Tableau 1). 3 Remontez le cadre de montage dans le boîtier mural 4 Remontez l la face sur le cadre de montage 5 Remontez les couvre-vis Montage du boîtier mural Des lunettes de protection doivent être portées pendant tout perçage ou burinage. Vérifiez qu’il n’y a aucune tuyauterie ou câble enfoui dans le mur ou d’obstructions à l’extérieur, par ex. électricité, gaz, eau. Pour le montage en saillie 1 Insérer des manchons appropriés dans les pastilles préformées 2 Faites passer les deux câbles dans les manchons 3 Fixez le boîtier mural et la bordure en plastique au mur, à l’aide des trous d’assemblage prévus 4 Reliez à nouveau le fil de terre au boîtier mural Pour le montage encastré 1 Faites un trou dans le mur suffisamment grand pour loger le boîtier mural. Jetez la bordure en plastique 2 Insérez des manchons appropriés dans les pastilles préformées 3 Faites passer les deux câbles dans ces manchons 4 Fixez le boîtier au mur. Assurez-vous que la bride du cadre de montage affleure la surface finie du mur. (Voir le schéma F6). 5 Rebrancher le fil de terre sur le boîtier encastré. Fig. 1 : Positions des presse-étoupe Fig. 2a : Retrait des couvercles de vis Utilisation de votre contrôleur Connectez au secteur 1 Assurez-vous que l’alimentation secteur est coupée et que les fusibles sont retirés 2 Faites passer le câble entre le commutateur d’isolation et le point de connexion à l’alimentation secteur 3 Faites toutes les connexions dans le commutateur d’isolation conformément aux instructions des fabricants. 4 En respectant tous les règlements locaux, branchez à l’alimentation secteur. 5 Faites une dernière vérification pour assurer que tous les points de mise à la terre sont connectés et que tous les couvercles ont été correctement remis sur le ventilateur, le contrôleur et le commutateur d’isolation. 6 Remettez tous les fusibles, et mettez sous tension secteur. Pour des circuits avec raccordement fixe, le fusible de protection de l’appareil ne doit pas dépasser 5 A. Pour l’Australie uniquement : Ces modèles sont reliés de manière permanente à l’alimentation et le fonctionnement est commandé par un interrupteur à distance. Ces modèles doivent être câblés directement au secteur à l’aide d’un commutateur mural de 10 A approuvé, avec un écartement des contacts d’au moins 3 mm Fig. 2b : Retrait de la face Fig. 2c : Retrait du cadre de montage Entretien du contrôleur Fonctionnement du contrôleur Nettoyage Le contrôleur comporte les caractéristiques suivantes : (Voir les schémas F1-F4). 1 Commutateur Marche/Arrêt 8 Cadre de montage 2 Commutateur aspiration/ 9 Boîtier mural extraction 10 Bordure plastique 3 Vitesse rapide/lente 11 Bornier du contrôleur 4 Voyant lumineux 12 Bornier du ventilateur 5 Fentes de ventilation 13 Interrupteur bipolaire de 6 Couvercle de vis coupure 7 Face 14 Fusibles 1 Avant de nettoyer, isolez complètement le contrôleur de l’alimentation électrique 2 Essuyez le couvercle soigneusement avec un chiffon humide 3 Séchez complètement 4 Assurez-vous toujours que les fentes de ventilation ne sont pas bouchées. ♦ N’immergez jamais le contrôleur dans de l’eau ou un autre liquide ♦ N’utilisez jamais de solvants forts pour ♦ nettoyer le contrôleur A part le nettoyage, aucun autre entretien n’est nécessaire. I Istruzioni per l'installazione ed il funzionamento del Regolatore FR22/30 per ventilatori Queste istruzioni sono soltanto per l'installazione ed il funzionamento del Regolatore FR22/30. Per le istruzioni di installazione e funzionamento del ventilatore consultare la documentazione fornita con il relativo ventilatore. Informazioni Generali Operazioni con i ventilatori Descrizione Identificazione del tipo di ventilatore Questo dispositivo è stato progettato per regolare il funzionamento dei ventilatori Xpelair della gamma GX9, GX12, WX9, WX12, RX9 e RX12 (montati a parete e su finestra). Il regolatore può essere montato in superficie oppure a incasso nella propria cassetta di metallo zincato. Si deve cablare un solo ventilatore a ciascun regolatore. Ai fini di queste istruzioni, le versioni correnti e precedenti dei ventilatori sono identificate come Tipo A e Tipo B, come segue: Installazione del regolatore Queste istruzioni sono intese per l'installazione del regolatore quando viene usato con ventilatori forniti da Xpelair. Il regolatore deve essere installato con cablaggio fisso. Controllare che l'alimentazione di rete corrisponda ai dati riportati sull'alloggiamento del regolatore. Questo dispositivo deve essere collegato a massa. Tipo A1 Tipo A2 Tipo B1 Tipo B2 Preparazione Tutte le installazioni devono essere eseguite sotto la supervisione di un elettricista qualificato. L'installazione e i cablaggi devono essere conformi alle norme IEE (Regno Unito) o alle relative norme locali (per altri Paesi). Se si desiderano ulteriori informazioni prima, durante e dopo l'installazione del regolatore, rivolgersi al numero di assistenza Xpelair nel Regno Unito (riportato all'ultima pagina). Clienti fuori del Regno Unito: rivolgersi al distributore locale Xpelair. Che cosa occorre all'installatore ♦ Un isolatore bipolare con una distanza minima tra i contatti di 3 mm (montaggio a parete o a soffitto). ♦ Cavo a 5 conduttori per collegare il regolatore al ventilatore. Se il ventilatore è montato su una finestra usare un cavo flessibile (disponibile presso Xpelair). ♦ Cavo a 3 conduttori per collegare il regolatore all'alimentazione di rete. Se si usa un cavo flessibile, si devono montare opportuni pressatreccia, che incorporano morsetti serrafilo, ai fori incompleti nella cassetta del regolatore (vedere fig. 1). Posizionamento del regolatore ♦ Non posizionare il regolatore dove la temperatura ambiente potrebbe superare 50ºC. ♦ Se viene installato in una cucina, non si deve montare il regolatore sopra una cappa di aspirazione o un grill all'altezza del viso. ♦ Se si prevede l'uso in atmosfere corrosive da sostanze chimiche, consultare il distributore locale Xpelair. ♦ Se vengono installati in una stanza da bagno o doccia, il regolatore e l'isolatore devono essere posizionati in modo che non possano essere toccati da chi usa il bagno o la doccia. Se si deve effettuare il collegamento ad un'installazione già esistente, isolare l'alimentazione di rete e togliere i relativi fusibili prima di qualunque procedura elettrica. Cablaggio a ventilatori Tipo A Nella presa del ventilatore, tra i morsetti 2 e 3 è montato un filo fusibile che deve essere tolto prima di collegare il regolatore, altrimenti il regolatore sarà permanentemente danneggiato. Cablaggio a ventilatori Tipo B Non è presente filo fusibile da togliere. Se il ventilatore è già installato: 1 Assicurarsi che l'alimentazione elettrica sia isolata. 2 Scollegare le connessioni di rete dalla presa terminale del ventilatore o dal blocco terminale. 3 Togliere il cablaggio esistente e renderlo sicuro. Se il ventilatore non è ancora installato: 1 Controllare che l'alimentazione elettrica nominale del ventilatore corrisponda all'alimentazione di rete. Cablaggio delle connessioni elettriche del ventilatore 1 Instradare il cavo a 5 conduttori dal ventilatore alla posizione del regolatore. 2 Cablare un'estremità del cavo nelle connessioni del ventilatore come indicato di seguito: TIPO DI VENTILATORE DIAGRAMMA Tipo A1 Tipo A2 Tipo B F1 F2 F3 Tabella 1. 3 Lasciare l'altra estremità pronta per essere collegata al regolatore. Montaggio del regolatore Togliere il coperchio e il telaio di montaggio Cablaggio delle connessioni elettriche del regolatore 1 Smontare la parte anteriore dal telaio di montaggio togliendo le coperture delle viti e due viti (vedere figg. 2a e 2b). 2 Staccare il telaio dalla cassetta a parete togliendo le due viti (vedere fig. 2c). 3 Allontanare la cassetta sollevandola dalla cornice di plastica. 4 Controllare che i dati elettrici nominali riportati all'interno del regolatore corrispondano all'alimentazione elettrica. 5 Scollegare il filo di massa dalla cassetta a parete. 6 Praticare fori di ingresso dei cavi nella cassetta di plastica e in quella di metallo aprendo i fori incompleti (vedere fig. 1). 1 Montare l'isolatore seguendo le istruzioni del fabbricante. 2 Cablare il regolatore all'isolatore ed al ventilatore, come indicato nel relativo diagramma (vedere la Tabella 1). 3 Rimontare il telaio di montaggio alla cassetta metallica a parete. 4 Rimontare il pannello al telaio di montaggio. 5 Rimettere i coperchi alle viti. Collegamento dell'alimentazione elettrica 1 Assicurarsi che l'alimentazione elettrica sia isolata e che i fusibili siano stati tolti. 2 Far passare il cavo dall'isolatore al punto di connessione Durante le operazioni di trapanatura e con l'alimentazione elettrica. scalpellatura si devono indossare protezioni 3 Eseguire tutte le connessioni nell'isolatore conformemente per gli occhi. alle istruzioni del fabbricante. Controllare vi siano tubioroCables cavi Check thereche arenon no buried Pipes 4 Eseguire le connessioni al punto dell'alimentazione elettrica nascosti nel muro o ostruzioni all’esterno, in the wall or obstructions on the outside per seguendo tutte le norme vigenti localmente. es. condotte perGas, elettricità, e.g. Electricity, Water. gas, acqua. 5 Eseguire una verifica finale per assicurarsi che tutti i punti Montaggio in superficie di massa siano collegati e che tutte le coperture siano state 1 Inserire pressatreccia adatti nei fori incompleti. rimesse a posto nel modo giusto sul ventilatore, regolatore 2 Far passare entrambi i cavi nei pressatreccia. ed isolatore. 3 Fissare al muro la cassetta e la cornice di plastica 6 Rimettere tutti i fusibili ed inserire l'alimentazione elettrica. utilizzando i fori di montaggio forniti. 4 Ricollegare il filo di massa alla cassetta a parete. Per i circuiti a cablaggio fisso, il fusibile di protezione Montaggio a incasso dell'apparecchio non deve essere superiore a 5 amp. 1 Praticare nella parete un foro abbastanza grande per alloggiare la cassetta. Gettare la cornice di plastica. Solo per l'Australia: 2 Inserire pressatreccia adatti nei fori incompleti. Questi modelli sono collegati in permanenza all'alimentazione 3 Far passare entrambi i cavi nei pressatreccia. e il funzionamento è controllato da un interruttore remoto. I 4 Fissare la cassetta alla parete. Assicurarsi che la flangia modelli devono essere cablati direttamente all'alimentazione del telaio di montaggio sia a filo con la superficie della tramite un interruttore di 10 amp approvato, montato in parete (vedere il diagramma F6). superficie sulla parete con almeno 3 mm di spazio tra i contatti. 5 Ricollegare il filo di massa alla cassetta a parete. Montaggio della cassetta a parete Fig. 1 : Posizioni dei pressatreccia del cavo Fig. 2a : Rimozione dei coperchi delle viti Fig. 2b: Rimozione del pannello Fig. 2c: Rimozione del telaio di montaggio Impiego del regolatore Manutenzione del regolatore Funzionamento del regolatore Pulizia Il regolatore ha le seguenti caratteristiche. (vedere i diagrammi F1-F4). 1 Interruttore On/Off 2 Interruttore aspirazione/ estrazione 3 Velocità alta/bassa 4 Spia luminosa 5 Fessure di ventilazione 6 Copri vite 7 Pannello 8 Telaio di montaggio 9 Cassetta a parete 10 Cornice di plastica 11 Blocco morsetti regolatore 12 Blocco morsetti ventilatore 13 Isolatore bipolare 14 Fusibili 1 Prima di procedere alla pulizia isolare completamente il regolatore dall'alimentazione elettrica. 2 Pulire delicatamente il coperchio con un panno umido. 3 Asciugare bene. 4 Assicurarsi che le fessure di ventilazione non siano mai ostruite. ♦ ♦ ♦ Non immergere mai il regolatore in acqua o altri liquidi. Non usare mai solventi per pulire il regolatore. Tranne la pulizia, non è necessaria altra manutenzione. ∂ÁηٿÛÙ·Û˘ Î·È §ÂÈÙÔ˘ÚÁ›·˜ ÙÔ˘ ƒ˘ıÌÈÛÙ‹ GR √‰ËÁ›Â˜ ∂Í·ÂÚÈÛÙ‹Ú· FR22/30 √È Ô‰ËÁ›Â˜ ·˘Ù¤˜ Â›Ó·È ÌfiÓÔ ÁÈ· ÙËÓ ÂÁηٿÛÙ·ÛË Î·È ÙË ÏÂÈÙÔ˘ÚÁ›· ÙÔ˘ ƒ˘ıÌÈÛÙ‹ ∂Í·ÂÚÈÛÙ‹Ú· FR22/30. °È· √‰ËÁ›Â˜ ∂ÁηٿÛÙ·Û˘ Î·È §ÂÈÙÔ˘ÚÁ›·˜ ∂Í·ÂÚÈÛÙ‹Ú· Û˘Ì‚Ô˘Ï¢ı›Ù ÙȘ Ô‰ËÁ›Â˜ Ô˘ Û˘ÓÔ‰Â‡Ô˘Ó ÙÔÓ Î¿ı ÂÍ·ÂÚÈÛÙ‹Ú·. °ÂÓÈΤ˜ ÏËÚÔÊÔڛ˜ ∏ ‰Ô˘ÏÂÈ¿ Û ۯ¤ÛË Ì ÙÔÓ ÂÍ·ÂÚÈÛÙ‹Ú· ¶ÂÚÈÁÚ·Ê‹ ∞Ó·ÁÓÒÚÈÛË ÙÔ˘ Ù‡Ô˘ ÙÔ˘ ÂÍ·ÂÚÈÛÙ‹Ú· ∏ Û˘Û΢‹ ÚÔÔÚ›˙ÂÙ·È ÁÈ· ÙË Ú‡ıÌÈÛË Ù˘ ÏÂÈÙÔ˘ÚÁ›·˜ ÙˆÓ ÂÍ·ÂÚÈÛÙ‹ÚˆÓ Xpelair ÙˆÓ ÛÂÈÚÒÓ GÃ9, GX12, WX9, WX12, RX9 Î·È RX12 (Ô˘ ÙÔÔıÂÙÔ‡ÓÙ·È Û ÙÔ›¯Ô˘˜ Î·È ·Ú¿ı˘Ú·). √ Ú˘ıÌÈÛÙ‹˜ ÌÔÚ› Ó· ÙÔÔıÂÙÂ›Ù·È Û ÂÈÊ¿ÓÂÈ· ‹ Û ÂÛÔ¯‹ ̤۷ ÛÙÔ ‰ÈÎfi ÙÔ˘ ÎÈ‚ÒÙÈÔ. ªÔÚ›Ù ӷ ηψ‰ÈÒÛÂÙ ÌfiÓÔ ¤Ó· ÂÍ·ÂÚÈÛÙ‹Ú· Û οı ڢıÌÈÛÙ‹. °È· ÙÔ˘˜ ÛÎÔÔ‡˜ ÙˆÓ Ô‰ËÁÈÒÓ ·˘ÙÒÓ, ÔÈ ÙÚ¤¯Ô˘Û˜ Î·È ÔÈ ÚÔËÁÔ‡ÌÂÓ˜ ÂΉfiÛÂȘ ÙˆÓ ÂÍ·ÂÚÈÛÙ‹ÚˆÓ ·Ó·ÁÓˆÚ›˙ÔÓÙ·È Û·Ó «∆‡Ô˜ ∞» Î·È «∆‡Ô˜ µ» ˆ˜ ÂÍ‹˜: ∂ÁηٿÛÙ·ÛË ÙÔ˘ Ú˘ıÌÈÛÙ‹ √È Ô‰ËÁ›Â˜ ·˘Ù¤˜ ÈÛ¯‡Ô˘Ó ÁÈ· ÙËÓ ÂÁηٿÛÙ·ÛË ÙÔ˘ Ú˘ıÌÈÛÙ‹ fiÙ·Ó ¯ÚËÛÈÌÔÔÈÂ›Ù·È ÛÂ Û˘Ó‰˘·ÛÌfi Ì ÂÍ·ÂÚÈÛÙ‹Ú˜ Ô˘ ÚÔÌËı‡ÔÓÙ·È ·fi ÙËÓ Xpelair. ∏ ÂÁηٿÛÙ·ÛË ÙÔ˘ Ú˘ıÌÈÛÙ‹ Ú¤ÂÈ Ó· Á›ÓÂÙ·È Û ÛÙ·ıÂÚ‹ ηψ‰›ˆÛË. µÂ‚·Èˆı›Ù fiÙÈ Ë ‰È·‚¿ıÌÈÛË Ù˘ ÎÂÓÙÚÈ΋˜ ËÏÂÎÙÚÈ΋˜ ·ÚÔ¯‹˜ Â›Ó·È Û‡ÌʈÓË Ì ÙË ‰È·‚¿ıÌÈÛË Ô˘ ·Ó·Ê¤ÚÂÙ·È ÛÙÔ ÂÚ›‚ÏËÌ· ÙÔ˘ Ú˘ıÌÈÛÙ‹. ∏ Û˘Û΢‹ ·˘Ù‹ Ú¤ÂÈ Ó· ÁÂÈÒÓÂÙ·È. ∏ fiÏË ÂÁηٿÛÙ·ÛË Ú¤ÂÈ Ó· ÂȂϤÂÙ·È ·fi ÂȉÈÎÂ˘Ì¤ÓÔ ËÏÂÎÙÚÔÏfiÁÔ. ∏ ÂÁηٿÛÙ·ÛË Î·È Ë Î·Ïˆ‰›ˆÛË Ú¤ÂÈ Ó· Û˘ÌÌÔÚÊÒÓÔÓÙ·È ÚÔ˜ ÙÔ˘˜ ÙÚ¤¯ÔÓÙ˜ ηÓÔÓÈÛÌÔ‡˜ ÙÔ˘ π∂∂ (ÛÙÔ ∏ӈ̤ÓÔ µ·Û›ÏÂÈÔ) ‹ ÙÔ˘˜ Û¯ÂÙÈÎÔ‡˜ ÂıÓÈÎÔ‡˜ ηÓÔÓÈÛÌÔ‡˜ (Û ¿ÏϘ ¯ÒÚ˜). ∞Ó ¤¯ÂÙ ÔÔÈÂÛ‰‹ÔÙ ÂÚˆÙ‹ÛÂȘ ÚÈÓ, ηٿ Î·È ÌÂÙ¿ ÙËÓ ÂÁηٿÛÙ·ÛË ÙÔ˘ Ú˘ıÌÈÛÙ‹, ·Ú·Î·Ï›Ûı ӷ ÌË ‰ÈÛÙ¿ÛÂÙ ӷ ÂÈÎÔÈÓˆÓ‹ÛÂÙ Ì ÙËÓ ÙËÏÂʈÓÈ΋ ÁÚ·ÌÌ‹ ¿ÌÂÛ˘ Û‡Ó‰ÂÛ˘ (hotline) Ù˘ Xpelair ÛÙÔ ∏ӈ̤ÓÔ µ·Û›ÏÂÈÔ (‚Ϥ ·ÚÈıÌfi ÛÙËÓ ›Ûˆ ÛÂÏ›‰·). √È ÂÎÙfi˜ ∏ӈ̤ÓÔ˘ µ·ÛÈÏ›Ԣ ÂÏ¿Ù˜ ÌÔÚÔ‡Ó Ó· ÂÈÎÔÈÓˆÓÔ‡Ó Ì ÙÔÓ ÙÔÈÎfi ‰È·ÓÔ̤· Ù˘ Xpelair. ∆È ı· ¯ÚÂÈ·ÛÙ› ÁÈ· ÙËÓ ÂÁηٿÛÙ·ÛË ● ● ● ¢ÈÔÏÈÎfi˜ ‰È·ÎfiÙ˘ ·ÔÌfiÓˆÛ˘ Ì ÂÏ¿¯ÈÛÙÔ ÎÂÓfi Â·Ê‹˜ 3 ¯ÛÙ. (ÁÈ· ÂÁηٿÛÙ·ÛË ÙÔ›¯Ô˘ ‹ ·Ú·ı‡ÚÔ˘). ∫·Ù¿ÏÏËÏ˘ ‰È·‚¿ıÌÈÛ˘ ηÏÒ‰ÈÔ 5 ˘Ú‹ÓˆÓ ÁÈ· ÙË Û‡Ó‰ÂÛË ÙÔ˘ Ú˘ıÌÈÛÙ‹ Ì ÙÔÓ ÂÍ·ÂÚÈÛÙ‹Ú·. ∞Ó ÚfiÎÂÈÙ·È ÁÈ· ÂÍ·ÂÚÈÛÙ‹Ú· ÙÔ›¯Ô˘, ¯ÚËÛÈÌÔÔÈ‹ÛÙ ‡ηÌÙÔ Î·ÏÒ‰ÈÔ (Ô˘ ‰È·Ù›ıÂÙ·È ·fi ÙËÓ Xpelair). ∫·Ù¿ÏÏËÏ˘ ‰È·‚¿ıÌÈÛ˘ ηÏÒ‰ÈÔ 3 ˘Ú‹ÓˆÓ ÁÈ· ÙË Û‡Ó‰ÂÛË ÙÔ˘ Ú˘ıÌÈÛÙ‹ Ì ÙËÓ ÎÂÓÙÚÈ΋ ËÏÂÎÙÚÈ΋ ·ÚÔ¯‹. ∞Ó ¯ÚËÛÈÌÔÔÈËı› ‡ηÌÙÔ Î·ÏÒ‰ÈÔ, ÛÙȘ ÙÚ‡˜ ÙÔ˘ ÎÈ‚ˆÙ›Ô˘ ÙÔ˘ Ú˘ıÌÈÛÙ‹ Ú¤ÂÈ Ó· ÙÔÔıÂÙËıÔ‡Ó Î·Ù¿ÏÏËÏÔÈ Û˘Ó‰ÂÙÈÎÔ› ‰·ÎÙ‡ÏÈÔÈ Ì ÂÓۈ̷و̤ÓÔ˘˜ ηψ‰È·ÎÔ‡˜ Û˘Ó‰¤ÛÌÔ˘˜ (‚Ϥ ™¯. 1). ¶Ô‡ ÙÔÔıÂÙÂ›Ù·È Ô Ú˘ıÌÈÛÙ‹˜ ● ● ● ● Ÿ¯È Û ÛËÌ›· fiÔ˘ Ë ÂÚÈ‚·ÏÏÔÓÙÈ΋ ıÂÚÌÔÎÚ·Û›· Â›Ó·È Èı·Ófi Ó· ˘ÂÚ‚·›ÓÂÈ ÙÔ˘˜ 50ÆC. ∞Ó ÚfiÎÂÈÙ·È ÁÈ· ÂÁηٿÛÙ·ÛË Û ÎÔ˘˙›Ó·, Ô Ú˘ıÌÈÛÙ‹˜ ‰ÂÓ Ú¤ÂÈ Ó· ÙÔÔıÂÙÂ›Ù·È ·Ì¤Ûˆ˜ ¿Óˆ ·fi ÙËÓ ÂÈÊ¿ÓÂÈ· Û˘Û΢‹˜ ÎÔ˘˙›Ó·˜ ‹ ¿Óˆ ·fi Û¯¿Ú· ÂÈ¤‰Ô˘ Ì·ÙÈÒÓ. ∞Ó ÚÔÔÚ›˙ÂÙ·È ÁÈ· ¯Ú‹ÛË Û Èı·ÓÒ˜ ¯ËÌÈο ‰È·‚ÚˆÙÈΤ˜ ·ÙÌfiÛÊ·ÈÚ˜, Û˘Ì‚Ô˘Ï¢ı›Ù ÙÔ ∆Ì‹Ì· ∆¯ÓÈÎÒÓ ÀËÚÂÛÈÒÓ Ù˘ ÂÙ·ÈÚ›·˜ Ì·˜ (Î·È ÂÎÙfi˜ ∏ӈ̤ÓÔ˘ µ·ÛÈÏ›Ԣ ÙÔÓ ÙÔÈÎfi ‰È·ÓÔ̤· Ù˘ Xpelair). ∞Ó ÚfiÎÂÈÙ·È ÁÈ· ÂÁηٿÛÙ·ÛË Û ÓÙÔ˘˜ ‹ Ì¿ÓÈÔ, Ô Ú˘ıÌÈÛÙ‹˜ Î·È Ô ‰È·ÎfiÙ˘ ·ÔÌfiÓˆÛ˘ Ú¤ÂÈ Ó· ‚Ú›ÛÎÔÓÙ·È Î¿Ô˘ Ô˘ Ó· ÌË ÌÔÚÔ‡Ó Ó· Ù· ÊÙ¿ÛÔ˘Ó ÔÈ ¯ÚËÛÈÌÔÔÈÔ‡ÓÙ˜ ÙÔ ÓÙÔ˘˜ ‹ ÙÔ Ì¿ÓÈÔ. ∆‡Ô˜ ∞1 ∆‡Ô˜ ∞2 ∆‡Ô˜ B1 ∆‡Ô˜ B2 ¶ÚÔÂÙÔÈÌ·Û›· ÙÔ˘ ÂÍ·ÂÚÈÛÙ‹Ú· ∞Ó Ë Î·Ïˆ‰›ˆÛË Á›ÓÂÙ·È Û ˘¿Ú¯Ô˘Û· ÂÁηٿÛÙ·ÛË, ·ÔÌÔÓÒÛÙ ÙËÓ ÎÂÓÙÚÈ΋ ·ÚÔ¯‹ Î·È ·Ê·ÈÚ¤ÛÙ ÙȘ ·ÓÙ›ÛÙÔȯ˜ ·ÛÊ¿ÏÂȘ ÚÈÓ ·fi οı ËÏÂÎÙÚÈ΋ ‰È·‰Èηۛ·. ∫·Ïˆ‰›ˆÛË Û ÂÍ·ÂÚÈÛÙ‹Ú˜ ∆‡Ô˘ ∞ ∆ÔÔıÂÙÂ›Ù·È ¤Ó·˜ Û‡Ó‰ÂÛÌÔ˜ ÌÂٷ͇ ÙˆÓ ·ÎÚÔ‰ÂÎÙÒÓ 2 Î·È 3 ÛÙËÓ Ú›˙· ÙÔ˘ ÂÍ·ÂÚÈÛÙ‹Ú·. ∞ÏÏ¿ Ú¤ÂÈ Ó· ·Ê·ÈÚÂı› ÚÈÓ ÙË Û‡Ó‰ÂÛË ÙÔ˘ Ú˘ıÌÈÛÙ‹. ∞Ó ‰ÂÓ ·Ê·ÈÚÂı›, Ô Ú˘ıÌÈÛÙ‹˜ ı· ˘ÔÛÙ› ÌfiÓÈÌË ‚Ï¿‚Ë. ∫·Ïˆ‰›ˆÛË Û ÂÍ·ÂÚÈÛÙ‹Ú˜ ∆‡Ô˘ µ ¢ÂÓ ˘¿Ú¯ÂÈ Î·Ïˆ‰È·Îfi˜ Û‡Ó‰ÂÛÌÔ˜ ÁÈ· ·Ê·›ÚÂÛË. ∞Ó Ô ÂÍ·ÂÚÈÛÙ‹Ú·˜ Â›Ó·È ‹‰Ë ÂÁηÙÂÛÙË̤ÓÔ˜ 1 µÂ‚·Èˆı›Ù fiÙÈ Ë ËÏÂÎÙÚÈ΋ ·ÚÔ¯‹ Â›Ó·È ·ÔÌÔӈ̤ÓË. 2 ∞Ê·ÈÚ¤ÛÙ ÙȘ Û˘Ó‰¤ÛÂȘ Ù˘ ËÏÂÎÙÚÈ΋˜ ·ÚÔ¯‹˜ ·fi ÙËÓ ÙÂÚÌ·ÙÈ΋ Ú›˙· ‹ ·fi ÙÔ ÙÂÚÌ·ÙÈÎfi ÌÏÔÎ. 3 ∞Ê·ÈÚ¤ÛÙ ÙËÓ ˘¿Ú¯Ô˘Û· ηψ‰›ˆÛË Î·È ·ÛÊ·Ï›ÛÙ ÙËÓ. ∞Ó Ô ÂÍ·ÂÚÈÛÙ‹Ú·˜ ‰ÂÓ ¤¯ÂÈ ·ÎfiÌ· ÂÁηٷÛÙ·ı› 1 µÂ‚·Èˆı›Ù fiÙÈ Ë ËÏÂÎÙÚÈ΋ ‰È·‚¿ıÌÈÛË ÙÔ˘ ÂÍ·ÂÚÈÛÙ‹Ú· Â›Ó·È Û‡ÌʈÓË Ì ÙËÓ ËÏÂÎÙÚÈ΋ ·ÚÔ¯‹. ∫·Ïˆ‰›ˆÛË ÙˆÓ ËÏÂÎÙÚÈÎÒÓ Û˘Ó‰¤ÛÂˆÓ ÙÔ˘ ÂÍ·ÂÚÈÛÙ‹Ú· 1 2 ¶ÂÚ¿ÛÙ ÙÔ Î·ÏÒ‰ÈÔ 5 ˘Ú‹ÓˆÓ ·fi ÙÔÓ ÂÍ·ÂÚÈÛÙ‹Ú· ÛÙË ı¤ÛË ÙÔ˘ Ú˘ıÌÈÛÙ‹. ∫·Ïˆ‰ÈÒÛÙ ÙË ÌÈ· ¿ÎÚË ÙÔ˘ ηψ‰›Ô˘ ÛÙȘ Û˘Ó‰¤ÛÂȘ ÙÔ˘ ÂÍ·ÂÚÈÛÙ‹Ú· fiˆ˜ ÂÎÙ›ıÂÙ·È ÈÔ Î¿Ùˆ: ∆À¶√™ ∂•∞∂ƒπ™∆∏ƒ∞ ¢π∞°ƒ∞ªª∞ ∆‡Ô˜ ∞1 ∆‡Ô˜ ∞2 ∆‡Ô˜ µ F1 F2 F3 ¶›Ó·Î·˜ 1 3 ∞Ê‹ÛÙ ÙËÓ ¿ÏÏË ¿ÎÚË ¤ÙÔÈÌË ÁÈ· Û‡Ó‰ÂÛË ÛÙÔÓ Ú˘ıÌÈÛÙ‹. ∆ÔÔı¤ÙËÛË ÙÔ˘ Ú˘ıÌÈÛÙ‹ ∞Ê·ÈÚ¤ÛÙ ÙÔ Î¿Ï˘ÌÌ· Î·È ÙÔ Ï·›ÛÈÔ ÂÁηٿÛÙ·Û˘ 1 2 3 4 5 6 ∞ÔÛ˘Ó‰¤ÛÙ ÙËÓ ÚfiÛÔ„Ë ·fi ÙÔ Ï·›ÛÈÔ ÂÁηٿÛÙ·Û˘ ·Ê·ÈÚÒÓÙ·˜ Ù· ηχÌÌ·Ù· ÙˆÓ ‚›‰ˆÓ Î·È ÙȘ ‰˘Ô ‚›‰Â˜ (µÏ¤ ™¯. 2· & ‚). ∞ÔÛ˘Ó‰¤ÛÙ ÙÔ Ï·›ÛÈÔ ÂÁηٿÛÙ·Û˘ ·fi ÙÔ ÎÈ‚ÒÙÈÔ ÙÔ›¯Ô˘ ·Ê·ÈÚÒÓÙ·˜ ÙȘ ‰˘Ô ‚›‰Â˜ (‚Ϥ ™¯. 2Á). ™ËÎÒÛÙ ÙÔ ÎÈ‚ÒÙÈÔ ÙÔ›¯Ô˘ ·fi ÙÔ Ï·ÛÙÈÎfi Ï·›ÛÈÔ. ∂ϤÁÍÙ ·Ó Ë ËÏÂÎÙÚÈ΋ ‰È·‚¿ıÌÈÛË Ô˘ ÂÎÙ›ıÂÙ·È Ì¤Û· ÛÙÔÓ Ú˘ıÌÈÛÙ‹ Â›Ó·È Û‡ÌʈÓË Ì ÙËÓ ËÏÂÎÙÚÈ΋ ·ÚÔ¯‹. ∞ÔÛ˘Ó‰¤ÛÙ ÙÔ Î·ÏÒ‰ÈÔ Á›ˆÛ˘ ·fi ÙÔ ÎÈ‚ÒÙÈÔ ÙÔ›¯Ô˘. ∞ÓÔ›ÍÙ ÙÚ‡˜ ÂÈÛfi‰Ô˘ ηψ‰›ˆÓ ÛÙÔ Ï·ÛÙÈÎfi Î·È ÙÔ ÌÂÙ·ÏÏÈÎfi ÎÈ‚ÒÙÈÔ ·Ê·ÈÚÒÓÙ·˜ Ù· ηٿÏÏËÏ· ÎÔ„›Ì·Ù· (‚Ϥ ™¯. 1). ∆ÔÔı¤ÙËÛË ÙÔ˘ ÎÈ‚ˆÙ›Ô˘ ÙÔ›¯Ô˘ ∫·Ù¿ ÙË ‰È¿ÚÎÂÈ· fiÏˆÓ ÙˆÓ ÂÚÁ·ÛÈÒÓ ÙÚ˘·Ó›ÛÌ·ÙÔ˜ Î·È ÛÌÈχ̷ÙÔ˜ Ú¤ÂÈ Ó· ÊÔÚ¿Ù ÚÔÛÙ·Û›· Ì·ÙÈÒÓ. µÂ‚·Èˆı›Ù fiÙÈ ‰ÂÓ ˘¿Ú¯Ô˘Ó ÛÙÔÓ ÙÔ›¯Ô Î·Ï˘Ì̤ÓÔÈ ÛˆÏ‹Ó˜ ‹ ηÏ҉ȷ ‹ ÂÌfi‰È· ÛÙÔ Â͈ÙÂÚÈÎfi .¯. ËÏÂÎÙÚÈÛÌfi˜, Áο˙È, ÓÂÚfi. ∞Ó ÙÔÔıÂÙÂ›Ù·È ÛÙËÓ ÂÈÊ¿ÓÂÈ· 1 ∂ÈÛ¿ÁÂÙ ηٿÏÏËÏÔ˘˜ Û˘Ó‰ÂÙÈÎÔ‡˜ ‰·ÎÙ˘Ï›Ô˘˜ ÛÙȘ ÙÚ‡˜. 2 ∆ÚÔÊÔ‰ÔÙ‹ÛÙÂ Î·È Ù· ‰˘Ô ηÏ҉ȷ ̤۷ ·fi ÙÔ˘˜ Û˘Ó‰ÂÙÈÎÔ‡˜ ‰·ÎÙ˘Ï›Ô˘˜. 3 ∆ÔÔıÂÙ‹ÛÙ ÙÔ ÎÈ‚ÒÙÈÔ ÙÔ›¯Ô˘ Î·È ÙÔ Ï·ÛÙÈÎfi Ï·›ÛÈÔ ÛÙÔÓ ÙÔ›¯Ô, ¯ÚËÛÈÌÔÔÈÒÓÙ·˜ ÙȘ ˘¿Ú¯Ô˘Û˜ ÙÚ‡˜ ÙÔÔı¤ÙËÛ˘. 4 ∂·Ó·Û˘Ó‰¤ÛÙ ÙÔ Î·ÏÒ‰ÈÔ Á›ˆÛ˘ ÛÙÔ ÎÈ‚ÒÙÈÔ ÙÔ›¯Ô˘. ∞Ó ÙÔÔıÂÙÂ›Ù·È Û ÂÛÔ¯‹ 1 ∞ÓÔ›ÍÙ ÌÈ· ÙÚ‡· ÛÙÔÓ ÙÔ›¯Ô ·ÚÎÂÙ¿ ÌÂÁ¿ÏË ÁÈ· Ó· ¯ˆÚ¤ÛÂÈ ÙÔ ÎÈ‚ÒÙÈÔ ÙÔ›¯Ô˘. ∞Ê·ÈÚ¤ÛÙ ÙÔ Ï·ÛÙÈÎfi Ï·›ÛÈÔ. 2 ∂ÈÛ¿ÁÂÙ ηٿÏÏËÏÔ˘˜ Û˘Ó‰ÂÙÈÎÔ‡˜ ‰·ÎÙ˘Ï›Ô˘˜ ÛÙȘ ÙÚ‡˜. 3 ∆ÚÔÊÔ‰ÔÙ‹ÛÙÂ Î·È Ù· ‰˘Ô ηÏ҉ȷ ̤۷ ·fi ÙÔ˘˜ Û˘Ó‰ÂÙÈÎÔ‡˜ ‰·ÎÙ˘Ï›Ô˘˜. 4 ∆ÔÔıÂÙ‹ÛÙ ÙÔ ÎÈ‚ÒÙÈÔ ÙÔ›¯Ô˘ ÛÙÔÓ ÙÔ›¯Ô. µÂ‚·Èˆı›Ù ™¯. 1: £¤ÛÂȘ Û˘Ó‰ÂÙÈÎÒÓ ‰·ÎÙ˘Ï›ˆÓ ηψ‰›Ô˘ ™¯. 2·: ∞Ê·›ÚÂÛË Î·Ï˘ÌÌ¿ÙˆÓ ‚›‰ˆÓ 3 4 5 6 7 ∫·Ïˆ‰›ˆÛË ÙÔ˘ ËÏÂÎÙÚÈÎÒÓ Û˘Ó‰¤ÛÂˆÓ ÙÔ˘ Ú˘ıÌÈÛÙ‹ 1 2 3 4 5 ∆ÔÔıÂÙ‹ÛÙ ÙÔÓ ‰È·ÎfiÙË ·ÔÌfiÓˆÛ˘ Û‡Ìʈӷ Ì ÙȘ Ô‰ËÁ›Â˜ ÙÔ˘ ηٷÛ΢·ÛÙ‹. ∫·Ïˆ‰ÈÒÛÙ ÙÔÓ Ú˘ıÌÈÛÙ‹ ÛÙÔÓ ‰È·ÎfiÙË ·ÔÌfiÓˆÛ˘ Î·È ÛÙÔÓ ÂÍ·ÂÚÈÛÙ‹Ú· fiˆ˜ Ê·›ÓÂÙ·È ÛÙÔ Î·Ù¿ÏÏËÏÔ ‰È¿ÁÚ·ÌÌ· (‚Ϥ ¶›Ó·Î· 1). ∂·Ó·ÙÔÔıÂÙ‹ÛÙ ÙÔ Ï·›ÛÈÔ ÂÁηٿÛÙ·Û˘ ÛÙÔ ÌÂÙ·ÏÏÈÎfi ÎÈ‚ÒÙÈÔ ÙÔ›¯Ô˘. ∂·Ó·ÙÔÔıÂÙ‹ÛÙ ÙËÓ ÚfiÛÔ„Ë ÛÙÔ Ï·›ÛÈÔ ÂÁηٿÛÙ·Û˘. ∂·Ó·ÙÔÔıÂÙ‹ÛÙ ٷ ηχÌÌ·Ù· ÙˆÓ ‚›‰ˆÓ. ™‡Ó‰ÂÛË ÛÙËÓ ËÏÂÎÙÚÈ΋ ·ÚÔ¯‹ 1 2 3 4 5 6 µÂ‚·Èˆı›Ù fiÙÈ Ë ËÏÂÎÙÚÈ΋ ·ÚÔ¯‹ Â›Ó·È ÎÏÂÈÛÙ‹ Î·È ÔÈ ·ÛÊ¿ÏÂȘ ¤¯Ô˘Ó ·Ê·ÈÚÂı›. ¶ÂÚ¿ÛÙ ÙÔ Î·ÏÒ‰ÈÔ ·fi ÙÔÓ ‰È·ÎfiÙË ·ÔÌfiÓˆÛ˘ ÛÙÔ ÛËÌÂ›Ô Û‡Ó‰ÂÛ˘ ÛÙËÓ ËÏÂÎÙÚÈ΋ ·ÚÔ¯‹. ∫¿ÓÂÙ fiϘ ÙȘ Û˘Ó‰¤ÛÂȘ ̤۷ ÛÙÔÓ ‰È·ÎfiÙË ·ÔÌfiÓˆÛ˘ Û‡Ìʈӷ Ì ÙȘ Ô‰ËÁ›Â˜ ÙÔ˘ ηٷÛ΢·ÛÙ‹. ∞ÎÔÏÔ˘ıÒÓÙ·˜ fiÏÔ˘˜ ÙÔ˘˜ ÙÔÈÎÔ‡˜ ηÓÔÓÈÛÌÔ‡˜ οÓÂÙ ÙË Û‡Ó‰ÂÛË ÛÙÔ ÛËÌÂ›Ô Ù˘ ËÏÂÎÙÚÈ΋˜ ·ÚÔ¯‹˜. ∫¿ÓÂÙ ¤Ó·Ó ÙÂÏÈÎfi ¤ÏÂÁ¯Ô ÁÈ· Ó· ‚‚·Èˆı›Ù fiÙÈ fiÏ· Ù· ÛËÌ›· Á›ˆÛ˘ Â›Ó·È Û˘Ó‰Â‰Â̤ӷ Î·È fiÏ· Ù· ηχÌÌ·Ù· ¤¯Ô˘Ó Â·Ó·ÙÔÔıÂÙËı› ÛˆÛÙ¿ ÛÙÔÓ ÂÍ·ÂÚÈÛÙ‹Ú·, ÙÔÓ Ú˘ıÌÈÛÙ‹ Î·È ÙÔÓ ‰È·ÎfiÙË ·ÔÌfiÓˆÛ˘. ∂·Ó·ÙÔÔıÂÙ‹ÛÙ fiϘ ÙȘ ·ÛÊ¿ÏÂȘ Î·È ·ÓÔ›ÍÙ ÙÔÓ ‰È·ÎfiÙË Ù˘ ËÏÂÎÙÚÈ΋˜ ·ÚÔ¯‹˜. °È· ΢ÎÏÒÌ·Ù· ÛÙ·ıÂÚ‹˜ ηψ‰›ˆÛ˘, Ë ·ÛÊ¿ÏÂÈ· Ù˘ Û˘Û΢‹˜ ‰ÂÓ Ú¤ÂÈ Ó· ˘ÂÚ‚·›ÓÂÈ Ù· 5 ·Ì¤Ú. °È· ÙËÓ ∞˘ÛÙÚ·Ï›· ÌfiÓÔ: ∆· ÌÔÓ٤Ϸ ·˘Ù¿ Â›Ó·È ÌfiÓÈÌ· Û˘Ó‰Â‰Â̤ӷ ÛÙËÓ ·ÚÔ¯‹ Î·È Ë ÏÂÈÙÔ˘ÚÁ›· ÙÔ˘˜ ÂϤÁ¯ÂÙ·È ·fi ·ÔÌ·ÎÚ˘Ṳ̂ÓÔ ‰È·ÎfiÙË. ¶Ú¤ÂÈ Ó· ηψ‰ÈÒÓÔÓÙ·È ¿ÌÂÛ· ÛÙËÓ ·ÚÔ¯‹ ̤ۈ ÂÁÎÂÎÚÈ̤ÓÔ˘ ‰È·ÎfiÙË ÂÈÊ·Ó›·˜ ÙÔ›¯Ô˘ 10 ·Ì¤Ú, Ì ÎÂÓfi ÌÂٷ͇ ÙˆÓ Â·ÊÒÓ ÙÔ˘Ï¿¯ÈÛÙÔ 3 ¯ÛÙ. ™¯. 2‚: ∞Ê·›ÚÂÛË Ù˘ ÚfiÛԄ˘ ™¯. 2Á: ∞Ê·›ÚÂÛË ÙÔ˘ Ï·ÈÛ›Ô˘ ÂÁηٿÛÙ·Û˘ ∏ ¯Ú‹ÛË ÙÔ˘ Ú˘ıÌÈÛÙ‹ Û·˜ ¶ÂÚÈÔ›ËÛË ÙÔ˘ Ú˘ıÌÈÛÙ‹ ∏ ÏÂÈÙÔ˘ÚÁ›· ÙÔ˘ Ú˘ıÌÈÛÙ‹ ∫·ı¿ÚÈÛÌ· √ Ú˘ıÌÈÛÙ‹˜ ¤¯ÂÈ Ù· ÈÔ Î¿Ùˆ ¯·Ú·ÎÙËÚÈÛÙÈο: (™˘Ì‚Ô˘Ï¢ı›Ù ٷ ‰È·ÁÚ¿ÌÌ·Ù· F1-F4). 1 2 5 fiÙÈ Ë ÊÏ¿ÓÙ˙· ÙÔ˘ Ï·ÈÛ›Ô˘ ÂÁηٿÛÙ·Û˘ ÂÊ·ÚÌfi˙ÂÈ ·ÎÚÈ‚Ò˜ ÛÙËÓ ÙÂÏÂȈ̤ÓË ÂÈÊ¿ÓÂÈ· ÙÔ˘ ÙÔ›¯Ô˘ (‚Ϥ ‰È¿ÁÚ·ÌÌ· F6). ∂·Ó·Û˘Ó‰¤ÛÙ ÙÔ Î·ÏÒ‰ÈÔ Á›ˆÛ˘ ÛÙÔ ÎÈ‚ÒÙÈÔ ÙÔ›¯Ô˘. ¢È·ÎfiÙ˘ On/Off ¢È·ÎfiÙ˘ ∂ÈÛ·ÁˆÁ‹˜/∂Í·ÁˆÁ‹˜ æËÏ‹/¯·ÌËÏ‹ Ù·¯‡ÙËÙ· ºˆ˜ ÂӉ›ÎÙË ™¯ÈṲ̂˜ ÂÍ·ÂÚÈÛÌÔ‡ ∫¿Ï˘ÌÌ· ‚›‰·˜ ¶ÚfiÛÔ„Ë 8 9 10 11 12 13 ¶Ï·›ÛÈÔ ÂÁηٿÛÙ·Û˘ ∫È‚ÒÙÈÔ ÙÔ›¯Ô˘ ¶Ï·ÛÙÈÎfi Ï·›ÛÈÔ ∆ÂÚÌ·ÙÈÎfi ÌÏÔÎ Ú˘ıÌÈÛÙ‹ ∆ÂÚÌ·ÙÈÎfi ÌÏÔÎ ÂÍ·ÂÚÈÛÙ‹Ú· ¢ÈÔÏÈÎfi˜ ‰È·ÎfiÙ˘ ·ÔÌfiÓˆÛ˘ 14 ∞ÛÊ¿ÏÂȘ 1 2 3 4 ¶ÚÈÓ ÙÔ Î·ı¿ÚÈÛÌ· ·ÔÌÔÓÒÓÂÙ ÙÔÓ Ú˘ıÌÈÛÙ‹ ÙÂÏ›ˆ˜ ·fi ÙËÓ ËÏÂÎÙÚÈ΋ ·ÚÔ¯‹. ™ÊÔÁÁ›ÛÙ ÚÔÛÂÎÙÈο ÙÔ Î¿Ï˘ÌÌ· Ì ¤Ó· ˘ÁÚfi ·Ó›. ™ÙÂÁÓÒÛÙ ÙÔ Î·Ï¿. ºÚÔÓÙ›˙ÂÙ ÔÈ Û¯ÈṲ̂˜ ÂÍ·ÂÚÈÛÌÔ‡ Ó· ÌËÓ Â›Ó·È ÔÙ¤ ‚Ô˘ÏˆÌ¤Ó˜. ● ªË ‚˘ı›˙ÂÙ ÔÙ¤ ÙÔÓ Ú˘ıÌÈÛÙ‹ ÛÙÔ ÓÂÚfi ‹ Û ¿ÏÏ· ˘ÁÚ¿. ● ªË ¯ÚËÛÈÌÔÔț٠ÔÙ¤ ‰È·Ï˘ÙÈο ÁÈ· Ó· ηı·Ú›ÛÂÙ ÙÔÓ Ú˘ıÌÈÛÙ‹. ● ∂ÎÙfi˜ ·fi ÙÔ Î·ı¿ÚÈÛÌ·, ηÌÌ›· ¿ÏÏË Û˘ÓÙ‹ÚËÛË ‰ÂÓ ¯ÚÂÈ¿˙ÂÙ·È. Do’s ◆ Do - Read all the instructions before commencing installation. ◆ Do - Install each fan with a double pole isolation switch. ◆ Do- Make sure that the mains supply is switched off before attempting to make electrical connections or carry out maintenance or cleaning. Guarantee Customers outside UK - see International below. ◆ UK: The fan is guaranteed against defects for 3 years from the date of purchase. ◆ Xpelair reserve the right to repair or replace at their option. ◆ Please keep your purchase receipt. ◆ If you have any problems, contact Xpelair’s Head Office at the address shown below. Technical advice and service Customers outside UK - see International below. UK: Xpelair have a comprehensive range of services including: ◆ Free technical advice help-desk from Engineers on all aspects of ventilation. ◆ Free design service, quotations and site surveys. ◆ Service and maintenance contracts to suit all requirements. Please ask for details: ◆ By telephone on Techline: +44 (0)8709 000430 ◆ By fax on Techfax: +44 (0)8709 000530 ◆ At the address below. Head Office, UK Sales Office and Spares Applied Energy Products Ltd, Morley Way, Peterborough PE2 9JJ England. Telephone: +44 (0)1733 456789 Fax: +44 (0)1733 310606 Sales/Spares Hotline: +44 (0)8709 000420 Sales/Spares Faxline: +44 (0)8709 000520 http://www.xpelair.co.uk International ◆ Guarantee: Contact your local distributor or Xpelair direct for details. ◆ Technical Advice and Service: Contact your local Xpelair distributor. FM 02118 QAS 3284/37 BS EN ISO 9001 Part No. 567 2054 01 (Issue E)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

APPLIED ENERGY FR22-30 Handleiding

Type
Handleiding
Deze handleiding is ook geschikt voor