Panasonic S125PT1E5 Handleiding

Type
Handleiding
62
INHOUDSOPGAVE
Pagina
PRODUCTINFORMATIE ............................................................................................................62
VEILIGHEIDSMAATREGELEN...................................................................................................62
INSTALLATIELOCATIE ..............................................................................................................63
ELEKTRISCHE VEREISTEN ......................................................................................................63
VEILIGHEIDSINSTRUCTIES......................................................................................................64
INFORMATIE...............................................................................................................................66
BEDIENING.................................................................................................................................67
DE LUCHTRICHTING AANPASSEN..........................................................................................68
VIA ÉÉN AFSTANDSBEDIENING (BEDRAAD) DE LUCHTRICHTING VOOR
MEERDERE BINNENUNITS AANPASSEN................................................................................70
SPECIALE OPMERKINGEN.......................................................................................................71
ONDERHOUD EN REINIGING...................................................................................................71
STORINGEN VERHELPEN ........................................................................................................72
CONTROLEREN VOORDAT U EEN REPARATEUR BELT.........................................................73
TIPS VOOR ENERGIEBESPARING ...........................................................................................73
SPECIFICATIE..........................................................................................................................135
PRODUCTINFORMATIE
Zorg ervoor dat u beschikt over de volgende informatie als u problemen of vragen hebt met
betrekking tot de airconditioner. Het model- en serienummer bevinden zich op het typeplaatje
aan de onderkant van de kast.
Modelnr. __________________________________ Serienr. _________________________
Aanschafdatum _______________________________________________________________
Adres van dealer ______________________________________________________________
Telefoonnummer ______________________________________________________________
VEILIGHEIDSMAATREGELEN
In deze gebruiksinstructies worden de volgende symbolen gebruikt om u attent te maken
op mogelijk gevaarlijke omstandigheden voor gebruikers, onderhoudspersoneel of het
apparaat:
Dit symbool verwijst naar een gevaar of onveilig
gebruik dat kan resulteren in ernstig persoonlijk
letsel of de dood.
Dit symbool verwijst naar een gevaar of onveilig
gebruik dat kan resulteren in persoonlijk letsel of
schade aan product of eigendommen.
WAARSCHUWING
06_85464609176013_NL.fm Page 62 Monday, November 12, 2012 9:25 AM
63
INSTALLATIELOCATIE
We raden u aan deze airconditioner op de juiste wijze te laten installeren door bevoegde
installatiemonteurs conform de installatie-instructies die u bij de unit hebt ontvangen.
Controleer vóór de installatie of het voltage van de stroomvoorziening in uw huis of kantoor
overeenkomt met het voltage op het typeplaatje.
ELEKTRISCHE VEREISTEN
1. Alle bedrading moet voldoen aan de lokale elektriciteitswetgeving. Neem contact op met uw
dealer of een bevoegd elektricien voor meer informatie.
2. Elke unit moet correct geaard zijn met een aardedraad of via de bedrading van de
stroomtoevoer.
3. De bedrading dient te worden aangelegd door een bevoegd elektricien.
Installeer de airconditioner niet in de buurt van dampen of ontvlambaar gas of in een
extreem vochtige ruimte, zoals een kas.
Installeer de airconditioner niet in de buurt van voorwerpen die extreem veel hitte
produceren.
Vermijd het volgende: Bescherm de airconditioner tegen ernstige roest door de buitenunit niet te installeren in de
buurt van opspattend zeewater of van minerale bronnen met zwavelhoudende lucht.
Ter opwarming van het systeem moet de
hoofdstroomschakelaar ten minste vijf (5) uur vóór het
gebruik zijn ingeschakeld. Laat de hoofdstroomschakelaar
op ON staan tenzij u het apparaat gedurende langere tijd niet
gebruikt.
Trek de stekker van het netsnoer uit het stopcontact of schakel de stroomonderbreker uit of
schakel de hoofdschakelaar uit om de airconditioner van de kamer volledig los te koppelen van
de netstroom als u het apparaat langere tijd niet gebruikt.
WAARSCHUWING
Hoofdstroomschakelaar
ON
OPMERKING
06_85464609176013_NL.fm Page 63 Monday, November 12, 2012 9:25 AM
64
VEILIGHEIDSINSTRUCTIES
Lees deze gebruiksinstructies zorgvuldig door voordat u de airconditioner gebruikt. Neem contact op met uw dealer als u nog
steeds problemen hebt.
Deze airconditioner is ontworpen om te zorgen voor aangename omstandigheden in uw kamer of andere ruimte. Gebruik het
apparaat alleen waarvoor het is bedoeld en zoals is beschreven in deze gebruiksinstructies.
Raadpleeg uw erkende dealer of een bevoegd specialist
omtrent het gebruik van het voorgeschreven koelmiddel.
Het gebruik van een ander dan het voorgeschreven type
kan barsten of andere schade aan de apparatuur
veroorzaken, met kans op persoonlijk letsel.
Raak de unit nooit met natte handen aan.
Gebruik of bewaar nooit benzine of andere ontvlambare
gassen of vloeistoffen in de buurt van de airconditioner. Dit
is zeer gevaarlijk.
Gebruik dit apparaat niet in een ruimte waar mogelijk
explosiegevaar dreigt.
Deze airconditioner heeft geen ventilator voor de inlaat van
frisse lucht van buiten. U moet regelmatig deuren of ramen
open zetten als u in dezelfde ruimte gas- of olieverwarming
gebruikt. Deze verbruiken namelijk veel zuurstof uit de
lucht. Als u dat niet doet, loopt u in extreme gevallen risico
op verstikking.
Zorg voor een apart stopcontact voor elke unit en in elke
afzonderlijke lijn voor een stroomschakelaar,
stroomonderbreker en aardlekschakelaar ter bescherming
tegen overstroom.
Zorg voor een apart stopcontact voor elke unit en conform
de bedradingsregels moet er volledige ontkoppeling, dat wil
zeggen een ontkoppeling van het stopcontact in alle polen
worden geïmplementeerd in de vaste bedrading.
Ter voorkoming van mogelijke gevaren vanwege
defecte isolatie moet de unit worden geaard.
Reinig nooit het binnenste van de binnen- en buitenunits.
Laat de reiniging uitvoeren door een bevoegde dealer of
specialist.
Repareer bij storingen dit apparaat niet zelf. Neem voor
reparaties contact op met de dealer of onderhoudsservice.
Lekkage van koelmiddelgas kan leiden tot brand.
Zorg er om veiligheidsredenen voor dat u de
airconditioner uitschakelt en ook de stekker uit
het stopcontact haalt voordat u het apparaat
reinigt of onderhoud pleegt.
Trek in geval van nood de stekker van het netsnoer uit het
stopcontact of schakel de stroomonderbreker uit of schakel
de hoofdschakelaar uit om de airconditioner van de kamer
volledig los te koppelen van de netstroom.
Steek uw vingers of andere voorwerpen niet in het
binnen- of buitendeel van de airconditioner. De
draaiende delen kunnen blessures veroorzaken.
Gebruik geen aangepaste kabels, zelf
verbonden kabels, verlengkabels of niet
vermelde kabels om oververhitting en brand te
vermijden.
WAARSCHUWING
Stop met het gebruiken van het product, wanneer er een
abnormaliteit/storing optreedt en haal de stekker uit het
stopcontact of schakel de stroomschakelaar en de
circuitbreker uit.
(Risico op rook/brand/elektrische schok)
Voorbeelden van abnormaliteit/storing
De ELCB stopt vaak.
Men merkt een brandgeur op.
Er wordt een abnormaal geluid of trilling van de eenheid
opgemerkt.
Er lekt water uit de binnenunit.
Stroomsnoer of stekker wordt abnormaal heet.
Ventilatorsnelheid kan niet geregeld worden.
De eenheid stopt onmiddellijk met werken, zelfs als
deze ingeschakeld is om te werken.
De ventilator stopt niet, zelfs niet als de eenheid stopt
met werken.
Neem onmiddellijk contact op met uw plaatselijke
leverancier voor onderhoud/reparatie.
Dit apparaat is bestemd voor gebruik door experts of
geïnstrueerde gebruikers in winkels, in de lichte industrie of
in agrarische bedrijven, alsmede voor commercieel gebruik
door leken.
Schakel de airconditioner niet in en uit via de
hoofdstroomschakelaar. Gebruik de ON/OFF-knop.
Steek geen voorwerpen in de luchtuitlaat van de
buitenunit. Dit is gevaarlijk omdat de ventilator op
hoge snelheid draait.
Raak de luchtinlaat of de scherpe aluminium bladen
van de buitenunit niet aan. Als u dat wel doet, kunt u
letsel oplopen.
Zorg voor een minimale afstand van 1,5 m tussen de unit
en het brandalarm en de luchtuitlaat.
Dit apparaat is niet bestemd voor gebruik door personen
(kinderen inbegrepen) met verminderde fysieke,
sensorische of mentale capaciteiten, of zonder ervaring of
kennis, tenzij onder toezicht van of na instructie door een
persoon die voor hun veiligheid verantwoordelijk is. Pas op
dat kinderen niet met het apparaat spelen.
Zorg ervoor dat u de ruimte niet te veel koelt of verwarmt
als er baby's of invalide personen aanwezig zijn.
Ga niet op de unit zitten of staan. Als u dat wel doet,
kunt u er vanaf vallen.
Steek geen voorwerpen in de
VENTILATORBEHUIZING.
Als u dat wel doet, kunt u letsel oplopen en
kan de unit beschadigd raken.
WAARSCHUWING
06_85464609176013_NL.fm Page 64 Monday, November 12, 2012 9:25 AM
65
Tijdens onweer kan de compressor af en toe stoppen. Dit is normaal. De unit start
weer automatisch na enkele minuten.
De Engelse tekst bevat de originele instructies. Tekst in andere talen is een
vertaling van de originele instructies.
Gebruik het product niet langer als zich een abnormale situatie of storing
voordoet en haal de stekker uit het stopcontact.
(Risico op rook/brand/elektrische schok)
Voorbeelden
van
abnormale
situaties/
storingen
- Het product start soms niet wanneer het wordt ingeschakeld.
- De stroomtoevoer wordt soms verbroken bij verplaatsing van het netsnoer.
- Als het apparaat in bedrijf is, ruikt u een verbrande geur of hoort u een abnormaal geluid.
- De kast is vervormd of abnormaal heet.
Neem onmiddellijk contact op met uw leverancier voor onderhoud/reparatie.
AANKONDIGING
06_85464609176013_NL.fm Page 65 Monday, November 12, 2012 9:25 AM
66
INFORMATIE
Bedrijfscondities
Gebruik deze airconditioner bij de volgende temperaturen.
Temperatuurbereik binnen:
Koelmodus 14°C ~ 25°C (*WBT) / 18°C ~ 32°C (*DBT)
Verwarmingsmodus 16°C ~ 30°C (*DBT)
Temperatuurbereik buiten:
Koelmodus -15°C ~ 46°C (*DBT)
*1 -10°C ~ 43°C (*DBT)
Verwarmingsmodus -20°C ~ 18°C (*WBT) / -20°C ~ 24°C (*DBT)
*1 -15°C ~ 18°C (*WBT) / -15°C ~ 24°C (*DBT)
*DBT: droge-boltemperatuur
*WBT: Wet-bulb temperature, natte-boltemperatuur
*1 Bij aansluiting van U-100PEY1E5, U-100PEY1E8, U-125PEY1E5, U-125PEY1E8
Informatie voor gebruikers betreffende het verzamelen en verwijderen van oude uitrustingen en lege batterijen
Voor zakengebruikers in de Europese Unie
[Informatie over de verwijdering in andere landen buiten de Europese Unie]
Opmerking over het batterijensymbool (beneden twee voorbeelden):
Pb
Deze symbolen op de producten, verpakkingen, en/of begeleidende documenten betekenen dat gebruikte
elektrische en elektronische producten en batterijen niet met het algemene huishoudelijke afval gemengd
mogen worden.
Voor een correcte behandeling, recuperatie en recyclage van oude producten en lege batterijen moeten zij
naar de bevoegde verzamelpunten gebracht worden in overeenstemming met uw nationale wetgeving en de
Richtlijnen 2002/96/EC en 2006/66/EC.
Door deze producten en batterijen correct te verwijderen draagt u uw steentje bij tot het beschermen van
waardevolle middelen en tot de preventie van potentiële negatieve effecten op de gezondheid van de mens
en op het milieu die anders door een onvakkundige afvalverwerking zouden kunnen ontstaan.
Voor meer informatie over het verzamelen en recycleren van oude producten en batterijen, gelieve contact
op te nemen met uw plaatselijke gemeente, uw afvalverwijderingsdiensten of de winkel waar u de goederen
gekocht hebt.
Voor een niet-correcte verwijdering van dit afval kunnen boetes opgelegd worden in overeenstemming met de
nationale wetgeving.
Indien u elektrische en elektronische uitrusting wilt vewijderen, neem dan contact op met uw dealer voor meer
informatie.
Deze symbolen zijn enkel geldig in de Europese Unie. Indien u wenst deze producten te verwijderen, neem
dan contact op met uw plaatselijke autoriteiten of dealer, en vraag informatie over de correcte wijze om deze
producten te verwijderen.
Dit symbool kan gebruikt worden in verbinding met een chemisch symbool. In dat geval wordt de eis,
vastgelegd door de Richtlijn voor de betrokken chemische producten vervuld.
06_85464609176013_NL.fm Page 66 Monday, November 12, 2012 9:25 AM
67
BEDIENING
Namen van de onderdelen
BINNENUNIT
Draadloze afstandsbediening (optionele onderdelen)
Timerafstandsbediening (optionele onderdelen)
Raadpleeg de gebruiksinstructies bij de optionele draadloze
afstandsbediening.
Raadpleeg de gebruiksinstructies bij de optionele
timerafstandsbediening.
Type Y1 (4-WEG CASSETTE 60×60)
Waterafvoer
Plafondpaneel
(optioneel)
Luchtuitlaat
(4 plaatsen)
Luchtinlaat-
rooster
(luchtinlaat)
Waterafvoer
(U kunt de
afvoerleiding
naar wens aan
de linker- of
rechterkant
bevestigen.)
Luchtinlaat-
rooster
(luchtinlaat)
Luchtuitlaat
Type T1 (PLAFOND)
Luchtinlaat
Luchtuitlaat
Type K1 (WANDMODEL)
OPMERKING
(Draadloos type:
beschikbaar voor alle
binnenunits)
OPMERKING
(Type met snoer:
beschikbaar voor alle
binnenunits)
06_85464609176013_NL.fm Page 67 Monday, November 12, 2012 9:25 AM
68
DE LUCHTRICHTING AANPASSEN
De functies variëren afhankelijk van de gebruikte binnenunit. U kunt via de afstandsbediening
de luchtrichting alleen instellen voor units die in onderstaande lijst voorkomen.
Type Y1, type T1, type K1:
Zet het blad (verticale luchtstroomblad) dat via de afstandsbediening wordt bediend, nooit
met uw handen in de gewenste positie.
Als de airconditioner wordt uitgeschakeld, gaat het blad (verticale luchtstroomblad)
automatisch in de neerwaartse positie.
Het blad (verticale luchtstroomblad) wordt in de opwaartse positie gezet als de standby-
stand voor verwarming actief is. De swingmodus wordt geactiveerd nadat de standby-stand
voor verwarming is vrijgegeven, maar al tijdens de standby-stand voor verwarming ziet u op
de afstandsbediening de swingmodus aangegeven.
De luchtrichting instellen De luchtrichting verandert iedere keer als u tijdens de werking op de knop FLAP
drukt.
De swingmodus
activeren
Druk op de knop FLAP om het blad (verticale luchtstroomblad) in de neerwaartse positie te
zetten en druk vervolgens nogmaals op de knop FLAP. U ziet . De luchtstroom gaat
automatisch op en neer.
De swingmodus stoppen Druk tijdens de swingmodus nogmaals op de knop FLAP om het blad in de gewenste positie
stop te zetten. Vervolgens kunt u de luchtstroom instellen vanuit de hoogste positie door
nogmaals op de knop FLAP te drukken.
Aanduiding dat de swingmodus is stopgezet.
Tijdens het koelen of drogen stopt het blad niet in de neerwaartse positie. Zelfs als het blad in
de swingmodus is stopgezet in de neerwaartse positie, stopt het blad pas in de derde positie
van boven.
Verwarmen Koelen en drogen Ventilator in
werking
Alle functies
Zet het blad (verticale luchtstroomblad) in de
neerwaartse positie. Als u het blad in de
opwaartse positie zet, bereikt de warme lucht
mogelijk niet de vloer.
Het blad (verticale
luchtstroomblad) kan in drie
posities worden gezet.
Startinstelling
Startinstelling
Startinstelling
Continue
werking
Ventilator en
verwarming
Koelen en drogen
06_85464609176013_NL.fm Page 68 Monday, November 12, 2012 9:25 AM
69
DE LUCHTRICHTING AANPASSEN (VERVOLG)
Airconditioners van het type Y1 zijn uitgerust met automatische bladen.
U kunt via de afstandsbediening de luchtrichting instellen op een specifieke hoek of op de
swingmodus.
Zet het blad niet met uw handen in een andere positie.
4-weg (type Y1) Het luchtuitlaatblad kan gemakkelijk worden verwijderd en afgewassen met water.
Zorg ervoor dat u altijd het apparaat uitschakelt voordat u het blad verwijdert.
Laat het blad na het afwassen drogen en plaats het vervolgens terug met de pijl naar buiten
gericht.
Plafondtype (T1)
Verticale richtingen (automatisch)
Deze airconditioner is uitgerust met een automatisch blad. U kunt via de afstandsbediening de
luchtrichting instellen op een specifieke hoek of op de swingmodus. (Raadpleeg de beschrijving
van de afstandsbediening.)
Zet het blad niet met uw handen in een andere positie.
Horizontale richtingen (handmatig)
U kunt de horizontale luchtrichting handmatig aanpassen door de verticale bladen naar links of
rechts te bewegen.
Wandtype (K1)
Verticale richtingen (automatisch)
Controleer of de afstandsbediening is ingeschakeld. Druk op de knop FLAP om het blad op en
neer te laten gaan. Druk nogmaals op de knop FLAP als u de bladbeweging wilt stopzetten om
de lucht in de gewenste richting te laten stromen. Richt het blad in de koelmodus niet naar
beneden en blijf binnen de koelingszone "A" om te voorkomen dat er condensatie op de vloer
druppelt. Zone "A" is de aanbevolen bladpositie voor koelen.
Nadat de airconditioner ongeveer één uur actief is geweest in de ingestelde luchtrichting, wordt
de richting automatisch gecontroleerd en wordt de positie van het blad gewijzigd. De
luchtrichting kan afwijken van de aanduiding op het display van de afstandsbediening.
Zet het blad niet met uw handen in een andere positie.
Horizontale richtingen (handmatig)
U kunt de horizontale luchtrichting handmatig aanpassen door de verticale bladen naar links of
rechts te bewegen.
Binnenunit
Zone "B" voor
verwarmen
Zone
"A" voor
koelen
06_85464609176013_NL.fm Page 69 Monday, November 12, 2012 9:25 AM
70
VIA ÉÉN AFSTANDSBEDIENING (BEDRAAD) DE
LUCHTRICHTING VOOR MEERDERE BINNENUNITS
AANPASSEN
Als op de afstandsbediening meerdere binnenunits zijn aangesloten, kunt u de luchtrichting
voor elke binnenunit afzonderlijk instellen door de binnenunit te selecteren (zie hierna).
Knop Auto Flap ( )
Druk op de knop UNIT om de luchtrichting voor afzonderlijke units in te stellen. Op het
display ziet u het nummer van de binnenunit onder groepsbediening. Stel de luchtrichting in
voor de binnenunit die is aangegeven op het display.
Elke keer als u op UNIT drukt, verandert de aanduiding in onderstaande volgorde.
Als u niets ziet, kunt u alle binnenunits in één keer instellen.
Het unitnummer wordt weergegeven als buitenunitnummer-binnenunitnummer. Het varieert
afhankelijk van het aantal units onder groepsbediening.
Eén buitenunit en acht binnenunits Twee buitenunits en vier binnenunits
Geen
display
Unitnr.
1–1
Unitnr.
1–2
Unitnr.
1–3
Unitnr.
1–8
Geen
display
Unit
Nr.
1–1
Unit
Nr.
1–2
Unit
Nr.
1–3
Unit
Nr.
2–4
Unit
Nr.
1–4
Unit
Nr.
2–1
06_85464609176013_NL.fm Page 70 Monday, November 12, 2012 9:25 AM
71
SPECIALE OPMERKINGEN
ONDERHOUD EN REINIGING
Werking Zodra in de ruimte de ingestelde temperatuur is bereikt, herhaalt de unit automatisch de in-
en uitschakelcyclus.
Om te voorkomen dat de vochtigheid in de ruimte weer stijgt, wordt ook de binnenventilator
uitgeschakeld als de unit wordt stopgezet.
De ventilatorsnelheid is automatisch ingesteld op "LO." en kan niet worden aangepast.
De "DROOG"-modus is niet mogelijk als de buitentemperatuur 15 °C of lager is.
Verwarmingsprestaties Omdat dit apparaat de ruimte verwarmt door middel van de warmte van de buitenlucht
(warmtepompsysteem), daalt het verwarmingsrendement bij een zeer lage
buitentemperatuur. Gebruik een ander verwarmingsapparaat in combinatie met deze unit
als de verwarming met deze warmtepomp onvoldoende is.
Ontdooien Als de buitentemperatuur laag is, kan zich rijp of ijs vormen op de warmtewisselaarsspiraal,
waardoor de verwarmingsprestaties afnemen. Als dit gebeurt, wordt het
microcomputergestuurde ontdooisysteem geactiveerd. Tegelijkertijd wordt de ventilator van
de binnenunit stopgezet (of in bepaalde gevallen heel laag gezet) en ziet u op het display de
aanduiding "STANDBY" tot het ontdooien is voltooid. Na enkele minuten wordt de
verwarmingsmodus hervat. (Dit interval varieert enigszins afhankelijk van de
buitentemperatuur en de manier waarop de rijp zich vormt.)
(standby) op het
display
De binnenventilator begint pas enkele minuten na de start van de verwarmingsmodus te
draaien (of draait in sommige gevallen zeer langzaam) totdat de
binnenwarmtewisselaarsspiraal voldoende is opgewarmd. Dit komt omdat een koude-
tochtpreventiesysteem actief is. Gedurende deze periode blijft de aanduiding " "
(standby) zichtbaar op het display.
" " (standby) blijft zichtbaar tijdens het ontdooien en als de compressor is uitgeschakeld
(of als de unit op zeer lage snelheid werkt) door de thermostaat als het systeem in de
verwarmingsmodus staat.
Als het ontdooien is voltooid en de compressor weer is ingeschakeld, wordt " " (standby)
automatisch uitgeschakeld als de verwarmingsmodus wordt hervat.
Stroomstoring tijdens de werking van de unit
Bij tijdelijke stroomuitval wordt de unit automatisch weer opgestart (na herstel van de
stroomtoevoer) met dezelfde instellingen als vóór de stroomstoring.
1. Zorg er om veiligheidsredenen voor dat u de airconditioner uitschakelt en ook de
stekker uit het stopcontact haalt voordat u het apparaat reinigt.
2. Giet geen water op de binnenunit om deze te reinigen. Als u dat wel doet,
beschadigt u de interne onderdelen en loopt u het risico op een elektrische schok.
Luchtinlaat- en -uitlaatzijde
(binnenunit)
Reinig de luchtinlaat- en uitlaatzijde van de binnenunit met de borstel van de stofzuiger of wrijf
ze schoon met een schone, zachte doek.
Gebruik bij vlekken op deze onderdelen een schone, met water bevochtigde doek. Zorg
ervoor dat u bij het reinigen van de luchtuitlaatzijde de bladen niet uit positie duwt.
1. Gebruik bij reiniging van de binnenunit nooit oplosmiddelen of scherpe chemische
stoffen. Wrijf kunststof onderdelen niet schoon met zeer heet water.
2. Sommige metalen randen en de bladen zijn scherp en kunnen letsel veroorzaken als
u ze verkeerd aanpakt. Pas daarom goed op als u deze onderdelen reinigt.
3. De interne spiraal en andere onderdelen van de buitenunit moeten regelmatig
worden gereinigd. Neem contact op met uw dealer of onderhoudsservice.
"DROOG"-modus
Verwarmingsmodus
OPMERKING
WAARSCHUWING
06_85464609176013_NL.fm Page 71 Monday, November 12, 2012 9:25 AM
72
STORINGEN VERHELPEN
Als uw airconditioner niet naar behoren werkt, controleert u dan eerst de volgende punten voordat u de hulp van een reparateur
inroept. Als het niet lukt om het probleem te verhelpen, raadpleegt u dan uw leverancier of een onderhoudsdienst.
BINNENUNIT
BUITENUNIT
Probleem Oorzaak
Lawaai Geluiden van stromend water tijdens
of na de werking.
Geluid van het koelmiddel dat door het apparaat stroomt.
Geluid van overtollig water dat via de afvoerbuis wordt afgevoerd.
Krakende geluiden tijdens of na de
werking
Geluiden van uitzettende of krimpende materialen door
temperatuurverandering.
Geur Tijdens de werking komt er een
vreemde geur uit het apparaat.
De geuren in huis, zoals etensluchtjes, parfum en sigarettenrook, zijn
door de airconditioner opgezogen en worden nu weer uitgeblazen.
Het inwendige van het apparaat is stoffig. Raadpleeg uw leverancier.
Condenswater
Tijdens de werking condenseert er
vocht uit de lucht in de buurt van de
luchtuitlaat.
Het vocht uit de lucht condenseert in de koelende luchtstroom en vormt
druppels.
Mist Er treedt mistvorming op tijdens de
koelwerking.
(Plaatsen waar vaak een vettige lucht
hangt, zoals in restaurants.)
Inwendig reinigen is noodzakelijk, aangezien het binnenwerk (de
warmtewisselaar) vuil is. Raadpleeg uw leverancier, aangezien het
nodige onderhoud technisch van aard is.
Tijdens het ontdooien
De ventilator draait een tijdje door, ook als is de
werking gestopt.
De ventilator draait door voor een soepele werking.
De ventilator kan soms blijven draaien door de drogende
warmtewisselaar, vanwege de instellingen.
De uitblaasrichting verandert tijdens de werking.
Instellen van de uitblaasrichting lukt niet.
De uitblaasrichting kan niet gewijzigd worden.
Wanneer de temperatuur van de uitgeblazen lucht erg laag is, evenals
tijdens het ontdooien, wordt automatisch de horizontale
uitblaasrichting aangehouden.
De stand van de jaloezien wordt soms afzonderlijk ingesteld.
Wanneer de uitblaasrichting wordt gewijzigd,
bewegen de jaloezien enkele malen achtereen, om
dan te stoppen in de gekozen stand.
Wanneer de uitblaasrichting wordt gewijzigd, bewegen de jaloezien na
het opzoeken van de normale uitgangsstand.
Stof Stofopeenhoping in de binnenunit wordt afgevoerd.
Wanneer u de ventilator voor het eerst op hoge
snelheid gebruikt, kan de ventilator soms sneller
draaien dan de instelsnelheid (3 tot 30 minuten).
Dit is om de werking te controleren en om te controleren of de rotatie van
de ventilatormotor binnen het gebruiksbereik ligt.
Probleem Oorzaak
Het
apparaat
werkt niet.
Onmiddellijk nadat het apparaat AAN
is gezet.
De werking begint nog even niet gedurende ongeveer de eerste 3
minuten, omdat het compressorbeveiligingscircuit is ingeschakeld.
Wanneer de werking wordt gestopt en
onmiddellijk hervat.
Lawaai Tijdens de verwarming klinken er vaak
bijgeluiden.
Tijdens het ontdooien
Stoom Tijdens de verwarming komt er vaak
stoom vrij.
Na stoppen met de afstandsbediening blijft de
ventilator van de buitenunit soms een tijdlang
doordraaien, ook al is de buitencompressor gestopt.
De ventilator draait door voor een soepele werking.
06_85464609176013_NL.fm Page 72 Monday, November 12, 2012 9:25 AM
73
CONTROLEREN VOORDAT U EEN REPARATEUR BELT
Als uw airconditioner nog steeds niet goed werkt, ook na het controleren van de bovenstaande punten, stopt u dan eerst de
werking en schakel de stroom uit. Neem vervolgens contact op met uw leverancier en geef het serienummer en de aard van het
probleem door. Probeer nooit om zelf uw airconditioner te repareren, want dat zou zeer gevaarlijk voor u kunnen zijn. Tevens
geeft u door of het inspectieteken en de letters E, F, H, L, P in combinatie met bepaalde cijfers verschijnen op het LCD-scherm
van de afstandsbediening.
TIPS VOOR ENERGIEBESPARING
Vermijden
Blokkeer de luchtinlaat en de uitblaasopening van het apparaat niet. Als n hiervan geblokkeerd wordt, zal het
apparaat niet goed werken en kan het schade oplopen.
Zorg dat er geen direct zonlicht de kamer binnenstroomt. Sluit de gordijnen, jaloezien of zongordijnen. Zolang de wanden of
het plafond van de kamer door de zon verwarmd worden, zal het koelen van de kamer langer duren.
Vooral doen
Houd het luchtfilter altijd zo schoon mogelijk. (Zie "ONDERHOUD EN REINIGING".) Bij een verstopt filter zullen de prestaties
van het apparaat afnemen.
Om te voorkomen dat de frisse lucht na airconditioning direct ontsnapt, dient u ramen, deuren en andere openingen gesloten
te houden.
Als de stroom uitvalt terwijl het apparaat in werking is
Als de stroomvoorziening van dit apparaat tijdelijk wegvalt, zal het apparaat automatisch de werking hervatten zodra het weer
stroom krijgt, met dezelfde instellingen als van vr de stroomonderbreking.
Probleem Oorzaak Oplossing
De airconditioner werkt
helemaal niet, ook al is de
stroom ingeschakeld.
Er is een stroomonderbreking
(geweest).
Druk weer op de AAN/UIT-toets van de
afstandsbediening.
De bedieningstoets staat in de uit-stand. Schakel de stroom weer in als de
hoofdstroomschakelaar werd uitgeschakeld.
Als de stroomonderbreker vanzelf is
uitgeschakeld, raadpleegt u dan uw leverancier
zonder opnieuw in te schakelen.
Er is een zekering gesprongen. Als er een zekering is gesprongen, raadpleegt u uw
leverancier.
Onvoldoende koeling of
verwarming
De luchtinlaat of luchtuitblaasopening
van de binnen- en buitenunits is verstopt
door stof of ander materiaal.
Verwijder het stof en blokkerend materiaal.
De windsnelheidsschakelaar staat op
"Low".
Schakel over naar "High" of "Strong".
Onjuiste temperatuurinstellingen Zie de "TIPS VOOR ENERGIEBESPARING".
Er komt direct zonlicht de kamer binnen
in de koelingsstand.
Er staan n of meer deuren en/of ramen
open.
Het luchtfilter is verstopt. Zie onder "ONDERHOUD EN REINIGING".
Te veel warmtebronnen in de kamer in
de koelingsstand.
Verminder het aantal warmtebronnen en gebruik ze
zo min mogelijk.
Te veel personen in de kamer in de
koelingsstand.
Verminder de temperatuurinstellingen of of schakel
over naar "High" of "Strong".
OPMERKING
06_85464609176013_NL.fm Page 73 Monday, November 12, 2012 9:25 AM
141
Compliance with regulation 842/EC/2006 Article 7(1) requirements
DO NOT VENT R410A INTO THE ATMOSPHERE: R410A IS A FLUORINATED
GREENHOUSE GAS, COVERED BY THE KYOTO PROTOCOL, WITH A
GLOBAL WARMING POTENTIAL (GWP) = 1975.
Conformité aux exigences de l’article 7 (1) de la réglementation 842/EC/
2006
NE PAS METTRE LE R410A À LAIR LIBRE: LE R410A EST UN GAZ À EFFET
DE SERRE FLUORÉ, RÉGULÉ PAR LE PROTOCOLE DE KYOTO AVEC UN
POTENTIEL DE RÉCHAUFFEMENT DE LA PLANÈTE (GWP) = 1975.
Cumplimiento de los requisitos del Artículo 7 (1) de la Directiva 842/EC/
2006
NO LIBERAR R410A AL AIRE LIBRE: EL R410A ES UN GAS FLUORIZADO
DE EFECTOS DE INVERNADERO, INCLUIDO EN EL PROTOCOLO DE
KYOTO, CON UN POTENCIAL DE CALENTAMIENTO GLOBAL (GWP) = 1975.
Kompatibilität mit den Anforderungen der Vorschrift 842/EC/2006, Artikel 7
(1)
R410A NICHT IN DIE AUSSENLUFT ABLASSEN: R410A IST EIN
FLUORIERTES TREIBHAUSGAS, DAS IM KYOTO-PROTOKOLL ENTHALTEN
IST UND EIN ERDERWÄRMUNGSPOTENTIAL (GWP) VON 1975 AUFWEIST.
Osservanza delle richieste dell’Articolo 7(1) delle regolamentazioni 842/
EC/2006
NON DISPERDERE R410A NELL’ATMOSFERA: L’R410A È UN GAS FLUORATO
CAUSA DI EFFETTO SERRA E COPERTO DAL PROTOCOLLO DI KYOTO CON
UN POTENZIALE DI RISCALDAMENTO GLOBALE (GWP) = 1975.
Voldoet aan de eisen van regeling 842/EC/2006 artikel 7(1)
LAAT R410A NIET ONSNAPPEN IN DE DAMPKRING: R410A IS EEN
FLUORHOUDEND BROEIKASGAS ZOALS BEDOELD IN HET KYOTO
PROTOCOL, MET EEN AARDOPWARMINGSVERMOGEN (GWP) = 1975.
Conformidade com o regulamento 842/EC/2006 Requisitos do Artigo 7(1)
NÃO DEIXE O R410A ESCAPAR PARA A ATMOSFERA: O R410A É UM GÁS
FLUORADO COM EFEITO DE ESTUFA, REGULADO PELO PROTOCOLO DE
QUIOTO, COM UM POTENCIAL DE AQUECIMENTO GLOBAL (GWP) = 1975.
Συμμόρφωση με τις απαιτήσεις του κανονισμού 842/EC/2006 Άρθρο 7(1)
ΜΗΝ ΑΠΕΛΕΥΘΕΡΩΣΕΤΕ ΤΟ R410A ΣΤΗΝ ΑΤΜΟΣΦΑΙΡΑ: ΤΟ R410A ΕΙΝΑΙ
ΦΘΟΡΙΟΥΧΟ ΑΕΡΙΟ ΘΕΡΜΟΚΗΠΙΟΥ ΠΟΥ ΚΑΛΥΠΤΕΤΑΙ ΑΠΟ ΤΟ
ΠΡΩΤΟΚΟΛΛΟ ΤΟΥ ΚYΟΤΟ, ΜΕ ΔΥΝΑΜΙΚΟ ΠΛΑΝΗΤΙΚΗΣ ΑΥΞΗΣΗΣ ΤΗΣ
ΘΕΡΜΟΚΡΑΣΙΑΣ (GWP) = 1975.
Съответствие с изискванията на 842/EC/2006 член 7(1)
НЕ ИЗПУСКТАЙТЕ R410A В АТМОСФЕРАТА: R410A Е ПАРНИКОВ ГАЗ,
СЪДЪРЖАЩ ФЛУОР, ВКЛЮЧЕН В ПРОТОКОЛА ОТ КИОТО С
ПОТЕНЦИАЛ ЗА ГЛОБАЛНО ЗАТОПЛЯНЕ (GWP) = 1975.
Соответствие требованиям Статьи 7(1) правил 842/EC/2006
НЕ ДОПУСКАЙТЕ ВЫБРОСОВ R410A В АТМОСФЕРУ: R410A ЯВЛЯЕТСЯ
ФТОРИРОВАННЫМ ПАРНИКОВЫМ ГАЗОМ, ОХВАТЫВАЕМЫМ
КИОТСКИМ ПРОТОКОЛОМ, С ПОТЕНЦИАЛОМ ГЛОБАЛЬНОГО
ПОТЕПЛЕНИЯ (GWP) = 1975.
Згідно норм 842/EC/2006 стаття 7(1)
НЕ ВИПУСКАЙТЕ R410A В АТМОСФЕРУ: R410A - ФТОРОВМІСНИЙ
ПАРНИКОВИЙ ГАЗ, ЩО ПІДПАДАЄ ПІД ДІЮ КІОТСЬКОГО ПРОТОКОЛУ, З
ПОТЕНЦІАЛОМ ГЛОБАЛЬНОГО ПОТЕПЛІННЯ (GWP) = 1975.
English
Français
Español
Deutsch
Italiano
Nederlands
Português
Eλληνικά
Български
Русский
Українська
12_85464609176013_Spec.fm Page 141 Friday, November 9, 2012 10:00 AM

Documenttranscriptie

06_85464609176013_NL.fm Page 62 Monday, November 12, 2012 9:25 AM INHOUDSOPGAVE Pagina PRODUCTINFORMATIE ............................................................................................................62 VEILIGHEIDSMAATREGELEN ...................................................................................................62 INSTALLATIELOCATIE ..............................................................................................................63 ELEKTRISCHE VEREISTEN ......................................................................................................63 VEILIGHEIDSINSTRUCTIES ......................................................................................................64 INFORMATIE...............................................................................................................................66 BEDIENING.................................................................................................................................67 DE LUCHTRICHTING AANPASSEN ..........................................................................................68 VIA ÉÉN AFSTANDSBEDIENING (BEDRAAD) DE LUCHTRICHTING VOOR MEERDERE BINNENUNITS AANPASSEN................................................................................70 SPECIALE OPMERKINGEN.......................................................................................................71 ONDERHOUD EN REINIGING ...................................................................................................71 STORINGEN VERHELPEN ........................................................................................................72 CONTROLEREN VOORDAT U EEN REPARATEUR BELT.........................................................73 TIPS VOOR ENERGIEBESPARING ...........................................................................................73 SPECIFICATIE..........................................................................................................................135 PRODUCTINFORMATIE Zorg ervoor dat u beschikt over de volgende informatie als u problemen of vragen hebt met betrekking tot de airconditioner. Het model- en serienummer bevinden zich op het typeplaatje aan de onderkant van de kast. Modelnr. __________________________________ Serienr. _________________________ Aanschafdatum _______________________________________________________________ Adres van dealer ______________________________________________________________ Telefoonnummer ______________________________________________________________ VEILIGHEIDSMAATREGELEN In deze gebruiksinstructies worden de volgende symbolen gebruikt om u attent te maken op mogelijk gevaarlijke omstandigheden voor gebruikers, onderhoudspersoneel of het apparaat: WAARSCHUWING Dit symbool verwijst naar een gevaar of onveilig gebruik dat kan resulteren in ernstig persoonlijk letsel of de dood. Dit symbool verwijst naar een gevaar of onveilig gebruik dat kan resulteren in persoonlijk letsel of schade aan product of eigendommen. 62 06_85464609176013_NL.fm Page 63 Monday, November 12, 2012 9:25 AM INSTALLATIELOCATIE • We raden u aan deze airconditioner op de juiste wijze te laten installeren door bevoegde installatiemonteurs conform de installatie-instructies die u bij de unit hebt ontvangen. • Controleer vóór de installatie of het voltage van de stroomvoorziening in uw huis of kantoor overeenkomt met het voltage op het typeplaatje. • WAARSCHUWING Vermijd het volgende: • Installeer de airconditioner niet in de buurt van dampen of ontvlambaar gas of in een extreem vochtige ruimte, zoals een kas. Installeer de airconditioner niet in de buurt van voorwerpen die extreem veel hitte produceren. Bescherm de airconditioner tegen ernstige roest door de buitenunit niet te installeren in de buurt van opspattend zeewater of van minerale bronnen met zwavelhoudende lucht. ELEKTRISCHE VEREISTEN 1. Alle bedrading moet voldoen aan de lokale elektriciteitswetgeving. Neem contact op met uw dealer of een bevoegd elektricien voor meer informatie. 2. Elke unit moet correct geaard zijn met een aardedraad of via de bedrading van de stroomtoevoer. 3. De bedrading dient te worden aangelegd door een bevoegd elektricien. Ter opwarming van het systeem moet de hoofdstroomschakelaar ten minste vijf (5) uur vóór het gebruik zijn ingeschakeld. Laat de hoofdstroomschakelaar op ON staan tenzij u het apparaat gedurende langere tijd niet gebruikt. OPMERKING Hoofdstroomschakelaar ON Trek de stekker van het netsnoer uit het stopcontact of schakel de stroomonderbreker uit of schakel de hoofdschakelaar uit om de airconditioner van de kamer volledig los te koppelen van de netstroom als u het apparaat langere tijd niet gebruikt. 63 06_85464609176013_NL.fm Page 64 Monday, November 12, 2012 9:25 AM VEILIGHEIDSINSTRUCTIES • • Lees deze gebruiksinstructies zorgvuldig door voordat u de airconditioner gebruikt. Neem contact op met uw dealer als u nog steeds problemen hebt. Deze airconditioner is ontworpen om te zorgen voor aangename omstandigheden in uw kamer of andere ruimte. Gebruik het apparaat alleen waarvoor het is bedoeld en zoals is beschreven in deze gebruiksinstructies. WAARSCHUWING Raadpleeg uw erkende dealer of een bevoegd specialist omtrent het gebruik van het voorgeschreven koelmiddel. Het gebruik van een ander dan het voorgeschreven type kan barsten of andere schade aan de apparatuur veroorzaken, met kans op persoonlijk letsel. Raak de unit nooit met natte handen aan. Gebruik of bewaar nooit benzine of andere ontvlambare gassen of vloeistoffen in de buurt van de airconditioner. Dit is zeer gevaarlijk. Gebruik dit apparaat niet in een ruimte waar mogelijk explosiegevaar dreigt. Deze airconditioner heeft geen ventilator voor de inlaat van frisse lucht van buiten. U moet regelmatig deuren of ramen open zetten als u in dezelfde ruimte gas- of olieverwarming gebruikt. Deze verbruiken namelijk veel zuurstof uit de lucht. Als u dat niet doet, loopt u in extreme gevallen risico op verstikking. WAARSCHUWING Stop met het gebruiken van het product, wanneer er een abnormaliteit/storing optreedt en haal de stekker uit het stopcontact of schakel de stroomschakelaar en de circuitbreker uit. (Risico op rook/brand/elektrische schok) Voorbeelden van abnormaliteit/storing • De ELCB stopt vaak. • Men merkt een brandgeur op. • Er wordt een abnormaal geluid of trilling van de eenheid opgemerkt. • Er lekt water uit de binnenunit. • Stroomsnoer of stekker wordt abnormaal heet. • Ventilatorsnelheid kan niet geregeld worden. • De eenheid stopt onmiddellijk met werken, zelfs als deze ingeschakeld is om te werken. • De ventilator stopt niet, zelfs niet als de eenheid stopt met werken. Neem onmiddellijk contact op met uw plaatselijke leverancier voor onderhoud/reparatie. Zorg voor een apart stopcontact voor elke unit en in elke afzonderlijke lijn voor een stroomschakelaar, stroomonderbreker en aardlekschakelaar ter bescherming tegen overstroom. Zorg voor een apart stopcontact voor elke unit en conform de bedradingsregels moet er volledige ontkoppeling, dat wil zeggen een ontkoppeling van het stopcontact in alle polen worden geïmplementeerd in de vaste bedrading. Ter voorkoming van mogelijke gevaren vanwege defecte isolatie moet de unit worden geaard. Reinig nooit het binnenste van de binnen- en buitenunits. Laat de reiniging uitvoeren door een bevoegde dealer of specialist. Repareer bij storingen dit apparaat niet zelf. Neem voor reparaties contact op met de dealer of onderhoudsservice. Lekkage van koelmiddelgas kan leiden tot brand. Zorg er om veiligheidsredenen voor dat u de airconditioner uitschakelt en ook de stekker uit het stopcontact haalt voordat u het apparaat reinigt of onderhoud pleegt. Trek in geval van nood de stekker van het netsnoer uit het stopcontact of schakel de stroomonderbreker uit of schakel de hoofdschakelaar uit om de airconditioner van de kamer volledig los te koppelen van de netstroom. Steek uw vingers of andere voorwerpen niet in het binnen- of buitendeel van de airconditioner. De draaiende delen kunnen blessures veroorzaken. Gebruik geen aangepaste kabels, zelf verbonden kabels, verlengkabels of niet vermelde kabels om oververhitting en brand te vermijden. 64 Dit apparaat is bestemd voor gebruik door experts of geïnstrueerde gebruikers in winkels, in de lichte industrie of in agrarische bedrijven, alsmede voor commercieel gebruik door leken. Schakel de airconditioner niet in en uit via de hoofdstroomschakelaar. Gebruik de ON/OFF-knop. Steek geen voorwerpen in de luchtuitlaat van de buitenunit. Dit is gevaarlijk omdat de ventilator op hoge snelheid draait. Raak de luchtinlaat of de scherpe aluminium bladen van de buitenunit niet aan. Als u dat wel doet, kunt u letsel oplopen. Zorg voor een minimale afstand van 1,5 m tussen de unit en het brandalarm en de luchtuitlaat. Dit apparaat is niet bestemd voor gebruik door personen (kinderen inbegrepen) met verminderde fysieke, sensorische of mentale capaciteiten, of zonder ervaring of kennis, tenzij onder toezicht van of na instructie door een persoon die voor hun veiligheid verantwoordelijk is. Pas op dat kinderen niet met het apparaat spelen. Zorg ervoor dat u de ruimte niet te veel koelt of verwarmt als er baby's of invalide personen aanwezig zijn. Ga niet op de unit zitten of staan. Als u dat wel doet, kunt u er vanaf vallen. Steek geen voorwerpen in de VENTILATORBEHUIZING. Als u dat wel doet, kunt u letsel oplopen en kan de unit beschadigd raken. 06_85464609176013_NL.fm Page 65 Monday, November 12, 2012 9:25 AM AANKONDIGING • • Tijdens onweer kan de compressor af en toe stoppen. Dit is normaal. De unit start weer automatisch na enkele minuten. De Engelse tekst bevat de originele instructies. Tekst in andere talen is een vertaling van de originele instructies. Gebruik het product niet langer als zich een abnormale situatie of storing voordoet en haal de stekker uit het stopcontact. (Risico op rook/brand/elektrische schok) Voorbeelden van abnormale situaties/ storingen - Het product start soms niet wanneer het wordt ingeschakeld. - De stroomtoevoer wordt soms verbroken bij verplaatsing van het netsnoer. - Als het apparaat in bedrijf is, ruikt u een verbrande geur of hoort u een abnormaal geluid. - De kast is vervormd of abnormaal heet. Neem onmiddellijk contact op met uw leverancier voor onderhoud/reparatie. 65 06_85464609176013_NL.fm Page 66 Monday, November 12, 2012 9:25 AM INFORMATIE Bedrijfscondities Gebruik deze airconditioner bij de volgende temperaturen. Temperatuurbereik binnen: Koelmodus 14°C ~ 25°C (*WBT) / 18°C ~ 32°C (*DBT) Verwarmingsmodus 16°C ~ 30°C (*DBT) Temperatuurbereik buiten: Koelmodus -15°C ~ 46°C (*DBT) *1 -10°C ~ 43°C (*DBT) Verwarmingsmodus -20°C ~ 18°C (*WBT) / -20°C ~ 24°C (*DBT) *1 -15°C ~ 18°C (*WBT) / -15°C ~ 24°C (*DBT) *DBT: droge-boltemperatuur *WBT: Wet-bulb temperature, natte-boltemperatuur *1 Bij aansluiting van U-100PEY1E5, U-100PEY1E8, U-125PEY1E5, U-125PEY1E8 Informatie voor gebruikers betreffende het verzamelen en verwijderen van oude uitrustingen en lege batterijen Deze symbolen op de producten, verpakkingen, en/of begeleidende documenten betekenen dat gebruikte elektrische en elektronische producten en batterijen niet met het algemene huishoudelijke afval gemengd mogen worden. Voor een correcte behandeling, recuperatie en recyclage van oude producten en lege batterijen moeten zij naar de bevoegde verzamelpunten gebracht worden in overeenstemming met uw nationale wetgeving en de Richtlijnen 2002/96/EC en 2006/66/EC. Door deze producten en batterijen correct te verwijderen draagt u uw steentje bij tot het beschermen van waardevolle middelen en tot de preventie van potentiële negatieve effecten op de gezondheid van de mens en op het milieu die anders door een onvakkundige afvalverwerking zouden kunnen ontstaan. Voor meer informatie over het verzamelen en recycleren van oude producten en batterijen, gelieve contact op te nemen met uw plaatselijke gemeente, uw afvalverwijderingsdiensten of de winkel waar u de goederen gekocht hebt. Voor een niet-correcte verwijdering van dit afval kunnen boetes opgelegd worden in overeenstemming met de nationale wetgeving. Pb 66 Voor zakengebruikers in de Europese Unie Indien u elektrische en elektronische uitrusting wilt vewijderen, neem dan contact op met uw dealer voor meer informatie. [Informatie over de verwijdering in andere landen buiten de Europese Unie] Deze symbolen zijn enkel geldig in de Europese Unie. Indien u wenst deze producten te verwijderen, neem dan contact op met uw plaatselijke autoriteiten of dealer, en vraag informatie over de correcte wijze om deze producten te verwijderen. Opmerking over het batterijensymbool (beneden twee voorbeelden): Dit symbool kan gebruikt worden in verbinding met een chemisch symbool. In dat geval wordt de eis, vastgelegd door de Richtlijn voor de betrokken chemische producten vervuld. 06_85464609176013_NL.fm Page 67 Monday, November 12, 2012 9:25 AM BEDIENING Namen van de onderdelen BINNENUNIT Type Y1 (4-WEG CASSETTE 60×60) Waterafvoer Type T1 (PLAFOND) Luchtuitlaat Waterafvoer (U kunt de afvoerleiding naar wens aan de linker- of rechterkant bevestigen.) Plafondpaneel (optioneel) Luchtuitlaat (4 plaatsen) Luchtinlaatrooster (luchtinlaat) Luchtinlaatrooster (luchtinlaat) Type K1 (WANDMODEL) Luchtinlaat Luchtuitlaat Draadloze afstandsbediening (optionele onderdelen) OPMERKING Raadpleeg de gebruiksinstructies bij de optionele draadloze afstandsbediening. (Draadloos type: beschikbaar voor alle binnenunits) Timerafstandsbediening (optionele onderdelen) OPMERKING Raadpleeg de gebruiksinstructies bij de optionele timerafstandsbediening. (Type met snoer: beschikbaar voor alle binnenunits) 67 06_85464609176013_NL.fm Page 68 Monday, November 12, 2012 9:25 AM DE LUCHTRICHTING AANPASSEN De functies variëren afhankelijk van de gebruikte binnenunit. U kunt via de afstandsbediening de luchtrichting alleen instellen voor units die in onderstaande lijst voorkomen. Type Y1, type T1, type K1: • • • De luchtrichting instellen De swingmodus activeren Zet het blad (verticale luchtstroomblad) dat via de afstandsbediening wordt bediend, nooit met uw handen in de gewenste positie. Als de airconditioner wordt uitgeschakeld, gaat het blad (verticale luchtstroomblad) automatisch in de neerwaartse positie. Het blad (verticale luchtstroomblad) wordt in de opwaartse positie gezet als de standbystand voor verwarming actief is. De swingmodus wordt geactiveerd nadat de standby-stand voor verwarming is vrijgegeven, maar al tijdens de standby-stand voor verwarming ziet u op de afstandsbediening de swingmodus aangegeven. De luchtrichting verandert iedere keer als u tijdens de werking op de knop FLAP drukt. Druk op de knop FLAP om het blad (verticale luchtstroomblad) in de neerwaartse positie te zetten en druk vervolgens nogmaals op de knop FLAP. U ziet . De luchtstroom gaat automatisch op en neer. Verwarmen Koelen en drogen Zet het blad (verticale luchtstroomblad) in de neerwaartse positie. Als u het blad in de opwaartse positie zet, bereikt de warme lucht mogelijk niet de vloer. Het blad (verticale luchtstroomblad) kan in drie posities worden gezet. Ventilator in werking Startinstelling Alle functies Continue werking Startinstelling Startinstelling De swingmodus stoppen Druk tijdens de swingmodus nogmaals op de knop FLAP om het blad in de gewenste positie stop te zetten. Vervolgens kunt u de luchtstroom instellen vanuit de hoogste positie door nogmaals op de knop FLAP te drukken. Aanduiding dat de swingmodus is stopgezet. Ventilator en verwarming Koelen en drogen Tijdens het koelen of drogen stopt het blad niet in de neerwaartse positie. Zelfs als het blad in de swingmodus is stopgezet in de neerwaartse positie, stopt het blad pas in de derde positie van boven. 68 06_85464609176013_NL.fm Page 69 Monday, November 12, 2012 9:25 AM DE LUCHTRICHTING AANPASSEN (VERVOLG) Airconditioners van het type Y1 zijn uitgerust met automatische bladen. U kunt via de afstandsbediening de luchtrichting instellen op een specifieke hoek of op de swingmodus. Zet het blad niet met uw handen in een andere positie. 4-weg (type Y1) • • • Het luchtuitlaatblad kan gemakkelijk worden verwijderd en afgewassen met water. Zorg ervoor dat u altijd het apparaat uitschakelt voordat u het blad verwijdert. Laat het blad na het afwassen drogen en plaats het vervolgens terug met de pijl naar buiten gericht. „ Plafondtype (T1) Verticale richtingen (automatisch) Deze airconditioner is uitgerust met een automatisch blad. U kunt via de afstandsbediening de luchtrichting instellen op een specifieke hoek of op de swingmodus. (Raadpleeg de beschrijving van de afstandsbediening.) Zet het blad niet met uw handen in een andere positie. Horizontale richtingen (handmatig) U kunt de horizontale luchtrichting handmatig aanpassen door de verticale bladen naar links of rechts te bewegen. „ Wandtype (K1) Binnenunit Verticale richtingen (automatisch) Controleer of de afstandsbediening is ingeschakeld. Druk op de knop FLAP om het blad op en neer te laten gaan. Druk nogmaals op de knop FLAP als u de bladbeweging wilt stopzetten om de lucht in de gewenste richting te laten stromen. Richt het blad in de koelmodus niet naar beneden en blijf binnen de koelingszone "A" om te voorkomen dat er condensatie op de vloer druppelt. Zone "A" is de aanbevolen bladpositie voor koelen. Nadat de airconditioner ongeveer één uur actief is geweest in de ingestelde luchtrichting, wordt de richting automatisch gecontroleerd en wordt de positie van het blad gewijzigd. De luchtrichting kan afwijken van de aanduiding op het display van de afstandsbediening. Zet het blad niet met uw handen in een andere positie. Zone "A" voor koelen Zone "B" voor verwarmen Horizontale richtingen (handmatig) U kunt de horizontale luchtrichting handmatig aanpassen door de verticale bladen naar links of rechts te bewegen. 69 06_85464609176013_NL.fm Page 70 Monday, November 12, 2012 9:25 AM VIA ÉÉN AFSTANDSBEDIENING (BEDRAAD) DE LUCHTRICHTING VOOR MEERDERE BINNENUNITS AANPASSEN Knop Auto Flap ( ) • Als op de afstandsbediening meerdere binnenunits zijn aangesloten, kunt u de luchtrichting voor elke binnenunit afzonderlijk instellen door de binnenunit te selecteren (zie hierna). • Druk op de knop UNIT om de luchtrichting voor afzonderlijke units in te stellen. Op het display ziet u het nummer van de binnenunit onder groepsbediening. Stel de luchtrichting in voor de binnenunit die is aangegeven op het display. Elke keer als u op UNIT drukt, verandert de aanduiding in onderstaande volgorde. Als u niets ziet, kunt u alle binnenunits in één keer instellen. Het unitnummer wordt weergegeven als buitenunitnummer-binnenunitnummer. Het varieert afhankelijk van het aantal units onder groepsbediening. • • • Eén buitenunit en acht binnenunits Geen display 70 Unitnr. 1–1 Unitnr. 1–2 Twee buitenunits en vier binnenunits Unitnr. 1–3 Unitnr. 1–8 Geen display Unit Nr. 1–1 Unit Nr. 1–2 Unit Nr. 1–3 Unit Nr. 1–4 Unit Nr. 2–1 Unit Nr. 2–4 06_85464609176013_NL.fm Page 71 Monday, November 12, 2012 9:25 AM SPECIALE OPMERKINGEN "DROOG"-modus Werking • • • • Zodra in de ruimte de ingestelde temperatuur is bereikt, herhaalt de unit automatisch de inen uitschakelcyclus. Om te voorkomen dat de vochtigheid in de ruimte weer stijgt, wordt ook de binnenventilator uitgeschakeld als de unit wordt stopgezet. De ventilatorsnelheid is automatisch ingesteld op "LO." en kan niet worden aangepast. De "DROOG"-modus is niet mogelijk als de buitentemperatuur 15 °C of lager is. Verwarmingsmodus Verwarmingsprestaties • Omdat dit apparaat de ruimte verwarmt door middel van de warmte van de buitenlucht (warmtepompsysteem), daalt het verwarmingsrendement bij een zeer lage buitentemperatuur. Gebruik een ander verwarmingsapparaat in combinatie met deze unit als de verwarming met deze warmtepomp onvoldoende is. Ontdooien • Als de buitentemperatuur laag is, kan zich rijp of ijs vormen op de warmtewisselaarsspiraal, waardoor de verwarmingsprestaties afnemen. Als dit gebeurt, wordt het microcomputergestuurde ontdooisysteem geactiveerd. Tegelijkertijd wordt de ventilator van de binnenunit stopgezet (of in bepaalde gevallen heel laag gezet) en ziet u op het display de aanduiding "STANDBY" tot het ontdooien is voltooid. Na enkele minuten wordt de verwarmingsmodus hervat. (Dit interval varieert enigszins afhankelijk van de buitentemperatuur en de manier waarop de rijp zich vormt.) (standby) op het display • De binnenventilator begint pas enkele minuten na de start van de verwarmingsmodus te draaien (of draait in sommige gevallen zeer langzaam) totdat de binnenwarmtewisselaarsspiraal voldoende is opgewarmd. Dit komt omdat een koudetochtpreventiesysteem actief is. Gedurende deze periode blijft de aanduiding " " (standby) zichtbaar op het display. " " (standby) blijft zichtbaar tijdens het ontdooien en als de compressor is uitgeschakeld (of als de unit op zeer lage snelheid werkt) door de thermostaat als het systeem in de verwarmingsmodus staat. Als het ontdooien is voltooid en de compressor weer is ingeschakeld, wordt " " (standby) automatisch uitgeschakeld als de verwarmingsmodus wordt hervat. • • OPMERKING Stroomstoring tijdens de werking van de unit Bij tijdelijke stroomuitval wordt de unit automatisch weer opgestart (na herstel van de stroomtoevoer) met dezelfde instellingen als vóór de stroomstoring. ONDERHOUD EN REINIGING WAARSCHUWING Luchtinlaat- en -uitlaatzijde (binnenunit) 1. Zorg er om veiligheidsredenen voor dat u de airconditioner uitschakelt en ook de stekker uit het stopcontact haalt voordat u het apparaat reinigt. 2. Giet geen water op de binnenunit om deze te reinigen. Als u dat wel doet, beschadigt u de interne onderdelen en loopt u het risico op een elektrische schok. Reinig de luchtinlaat- en uitlaatzijde van de binnenunit met de borstel van de stofzuiger of wrijf ze schoon met een schone, zachte doek. Gebruik bij vlekken op deze onderdelen een schone, met water bevochtigde doek. Zorg ervoor dat u bij het reinigen van de luchtuitlaatzijde de bladen niet uit positie duwt. 1. Gebruik bij reiniging van de binnenunit nooit oplosmiddelen of scherpe chemische stoffen. Wrijf kunststof onderdelen niet schoon met zeer heet water. 2. Sommige metalen randen en de bladen zijn scherp en kunnen letsel veroorzaken als u ze verkeerd aanpakt. Pas daarom goed op als u deze onderdelen reinigt. 3. De interne spiraal en andere onderdelen van de buitenunit moeten regelmatig worden gereinigd. Neem contact op met uw dealer of onderhoudsservice. 71 06_85464609176013_NL.fm Page 72 Monday, November 12, 2012 9:25 AM STORINGEN VERHELPEN Als uw airconditioner niet naar behoren werkt, controleert u dan eerst de volgende punten voordat u de hulp van een reparateur inroept. Als het niet lukt om het probleem te verhelpen, raadpleegt u dan uw leverancier of een onderhoudsdienst. BINNENUNIT Probleem Lawaai Geur Oorzaak Geluiden van stromend water tijdens of na de werking. • • Geluid van het koelmiddel dat door het apparaat stroomt. Geluid van overtollig water dat via de afvoerbuis wordt afgevoerd. Krakende geluiden tijdens of na de werking Geluiden van uitzettende of krimpende materialen door temperatuurverandering. Tijdens de werking komt er een vreemde geur uit het apparaat. De geuren in huis, zoals etensluchtjes, parfum en sigarettenrook, zijn door de airconditioner opgezogen en worden nu weer uitgeblazen. Het inwendige van het apparaat is stoffig. Raadpleeg uw leverancier. Condenswater Tijdens de werking condenseert er vocht uit de lucht in de buurt van de luchtuitlaat. Het vocht uit de lucht condenseert in de koelende luchtstroom en vormt druppels. Mist • Er treedt mistvorming op tijdens de koelwerking. (Plaatsen waar vaak een vettige lucht hangt, zoals in restaurants.) • Inwendig reinigen is noodzakelijk, aangezien het binnenwerk (de warmtewisselaar) vuil is. Raadpleeg uw leverancier, aangezien het nodige onderhoud technisch van aard is. Tijdens het ontdooien De ventilator draait een tijdje door, ook als is de werking gestopt. • • De ventilator draait door voor een soepele werking. De ventilator kan soms blijven draaien door de drogende warmtewisselaar, vanwege de instellingen. De uitblaasrichting verandert tijdens de werking. Instellen van de uitblaasrichting lukt niet. De uitblaasrichting kan niet gewijzigd worden. • Wanneer de temperatuur van de uitgeblazen lucht erg laag is, evenals tijdens het ontdooien, wordt automatisch de horizontale uitblaasrichting aangehouden. De stand van de jaloezien wordt soms afzonderlijk ingesteld. • Wanneer de uitblaasrichting wordt gewijzigd, bewegen de jaloezien enkele malen achtereen, om dan te stoppen in de gekozen stand. Wanneer de uitblaasrichting wordt gewijzigd, bewegen de jaloezien na het opzoeken van de normale uitgangsstand. Stof Stofopeenhoping in de binnenunit wordt afgevoerd. Wanneer u de ventilator voor het eerst op hoge snelheid gebruikt, kan de ventilator soms sneller draaien dan de instelsnelheid (3 tot 30 minuten). Dit is om de werking te controleren en om te controleren of de rotatie van de ventilatormotor binnen het gebruiksbereik ligt. BUITENUNIT Probleem Oorzaak Het apparaat werkt niet. Onmiddellijk nadat het apparaat AAN is gezet. De werking begint nog even niet gedurende ongeveer de eerste 3 minuten, omdat het compressorbeveiligingscircuit is ingeschakeld. Lawaai Tijdens de verwarming klinken er vaak Tijdens het ontdooien bijgeluiden. Stoom Tijdens de verwarming komt er vaak stoom vrij. Wanneer de werking wordt gestopt en onmiddellijk hervat. Na stoppen met de afstandsbediening blijft de De ventilator draait door voor een soepele werking. ventilator van de buitenunit soms een tijdlang doordraaien, ook al is de buitencompressor gestopt. 72 06_85464609176013_NL.fm Page 73 Monday, November 12, 2012 9:25 AM CONTROLEREN VOORDAT U EEN REPARATEUR BELT Probleem De airconditioner werkt helemaal niet, ook al is de stroom ingeschakeld. Oorzaak Er is een stroomonderbreking (geweest). Oplossing Druk weer op de AAN/UIT-toets van de afstandsbediening. De bedieningstoets staat in de uit-stand. • • Er is een zekering gesprongen. Onvoldoende koeling of verwarming Schakel de stroom weer in als de hoofdstroomschakelaar werd uitgeschakeld. Als de stroomonderbreker vanzelf is uitgeschakeld, raadpleegt u dan uw leverancier zonder opnieuw in te schakelen. Als er een zekering is gesprongen, raadpleegt u uw leverancier. Verwijder het stof en blokkerend materiaal. De luchtinlaat of luchtuitblaasopening van de binnen- en buitenunits is verstopt door stof of ander materiaal. De windsnelheidsschakelaar staat op "Low". Schakel over naar "High" of "Strong". Onjuiste temperatuurinstellingen Zie de "TIPS VOOR ENERGIEBESPARING". Er komt direct zonlicht de kamer binnen in de koelingsstand. Er staan n of meer deuren en/of ramen open. Het luchtfilter is verstopt. Zie onder "ONDERHOUD EN REINIGING". Te veel warmtebronnen in de kamer in de koelingsstand. Verminder het aantal warmtebronnen en gebruik ze zo min mogelijk. Te veel personen in de kamer in de koelingsstand. Verminder de temperatuurinstellingen of of schakel over naar "High" of "Strong". Als uw airconditioner nog steeds niet goed werkt, ook na het controleren van de bovenstaande punten, stopt u dan eerst de werking en schakel de stroom uit. Neem vervolgens contact op met uw leverancier en geef het serienummer en de aard van het probleem door. Probeer nooit om zelf uw airconditioner te repareren, want dat zou zeer gevaarlijk voor u kunnen zijn. Tevens geeft u door of het inspectieteken en de letters E, F, H, L, P in combinatie met bepaalde cijfers verschijnen op het LCD-scherm van de afstandsbediening. TIPS VOOR ENERGIEBESPARING Vermijden • • Blokkeer de luchtinlaat en de uitblaasopening van het apparaat niet. Als n hiervan geblokkeerd wordt, zal het apparaat niet goed werken en kan het schade oplopen. Zorg dat er geen direct zonlicht de kamer binnenstroomt. Sluit de gordijnen, jaloezien of zongordijnen. Zolang de wanden of het plafond van de kamer door de zon verwarmd worden, zal het koelen van de kamer langer duren. Vooral doen • • Houd het luchtfilter altijd zo schoon mogelijk. (Zie "ONDERHOUD EN REINIGING".) Bij een verstopt filter zullen de prestaties van het apparaat afnemen. Om te voorkomen dat de frisse lucht na airconditioning direct ontsnapt, dient u ramen, deuren en andere openingen gesloten te houden. OPMERKING Als de stroom uitvalt terwijl het apparaat in werking is Als de stroomvoorziening van dit apparaat tijdelijk wegvalt, zal het apparaat automatisch de werking hervatten zodra het weer stroom krijgt, met dezelfde instellingen als van vr de stroomonderbreking. 73 12_85464609176013_Spec.fm Page 141 Friday, November 9, 2012 10:00 AM English Compliance with regulation 842/EC/2006 Article 7(1) requirements DO NOT VENT R410A INTO THE ATMOSPHERE: R410A IS A FLUORINATED GREENHOUSE GAS, COVERED BY THE KYOTO PROTOCOL, WITH A GLOBAL WARMING POTENTIAL (GWP) = 1975. Français Conformité aux exigences de l’article 7 (1) de la réglementation 842/EC/ 2006 NE PAS METTRE LE R410A À L’AIR LIBRE: LE R410A EST UN GAZ À EFFET DE SERRE FLUORÉ, RÉGULÉ PAR LE PROTOCOLE DE KYOTO AVEC UN POTENTIEL DE RÉCHAUFFEMENT DE LA PLANÈTE (GWP) = 1975. Español Cumplimiento de los requisitos del Artículo 7 (1) de la Directiva 842/EC/ 2006 NO LIBERAR R410A AL AIRE LIBRE: EL R410A ES UN GAS FLUORIZADO DE EFECTOS DE INVERNADERO, INCLUIDO EN EL PROTOCOLO DE KYOTO, CON UN POTENCIAL DE CALENTAMIENTO GLOBAL (GWP) = 1975. Deutsch Kompatibilität mit den Anforderungen der Vorschrift 842/EC/2006, Artikel 7 (1) R410A NICHT IN DIE AUSSENLUFT ABLASSEN: R410A IST EIN FLUORIERTES TREIBHAUSGAS, DAS IM KYOTO-PROTOKOLL ENTHALTEN IST UND EIN ERDERWÄRMUNGSPOTENTIAL (GWP) VON 1975 AUFWEIST. Italiano Osservanza delle richieste dell’Articolo 7(1) delle regolamentazioni 842/ EC/2006 NON DISPERDERE R410A NELL’ATMOSFERA: L’R410A È UN GAS FLUORATO CAUSA DI EFFETTO SERRA E COPERTO DAL PROTOCOLLO DI KYOTO CON UN POTENZIALE DI RISCALDAMENTO GLOBALE (GWP) = 1975. Nederlands Voldoet aan de eisen van regeling 842/EC/2006 artikel 7(1) LAAT R410A NIET ONSNAPPEN IN DE DAMPKRING: R410A IS EEN FLUORHOUDEND BROEIKASGAS ZOALS BEDOELD IN HET KYOTO PROTOCOL, MET EEN AARDOPWARMINGSVERMOGEN (GWP) = 1975. Português Conformidade com o regulamento 842/EC/2006 Requisitos do Artigo 7(1) NÃO DEIXE O R410A ESCAPAR PARA A ATMOSFERA: O R410A É UM GÁS FLUORADO COM EFEITO DE ESTUFA, REGULADO PELO PROTOCOLO DE QUIOTO, COM UM POTENCIAL DE AQUECIMENTO GLOBAL (GWP) = 1975. Eλληνικά Συμμόρφωση με τις απαιτήσεις του κανονισμού 842/EC/2006 Άρθρο 7(1) ΜΗΝ ΑΠΕΛΕΥΘΕΡΩΣΕΤΕ ΤΟ R410A ΣΤΗΝ ΑΤΜΟΣΦΑΙΡΑ: ΤΟ R410A ΕΙΝΑΙ ΦΘΟΡΙΟΥΧΟ ΑΕΡΙΟ ΘΕΡΜΟΚΗΠΙΟΥ ΠΟΥ ΚΑΛΥΠΤΕΤΑΙ ΑΠΟ ΤΟ ΠΡΩΤΟΚΟΛΛΟ ΤΟΥ ΚYΟΤΟ, ΜΕ ΔΥΝΑΜΙΚΟ ΠΛΑΝΗΤΙΚΗΣ ΑΥΞΗΣΗΣ ΤΗΣ ΘΕΡΜΟΚΡΑΣΙΑΣ (GWP) = 1975. Български Съответствие с изискванията на 842/EC/2006 член 7(1) НЕ ИЗПУСКТАЙТЕ R410A В АТМОСФЕРАТА: R410A Е ПАРНИКОВ ГАЗ, СЪДЪРЖАЩ ФЛУОР, ВКЛЮЧЕН В ПРОТОКОЛА ОТ КИОТО С ПОТЕНЦИАЛ ЗА ГЛОБАЛНО ЗАТОПЛЯНЕ (GWP) = 1975. Русский Соответствие требованиям Статьи 7(1) правил 842/EC/2006 НЕ ДОПУСКАЙТЕ ВЫБРОСОВ R410A В АТМОСФЕРУ: R410A ЯВЛЯЕТСЯ ФТОРИРОВАННЫМ ПАРНИКОВЫМ ГАЗОМ, ОХВАТЫВАЕМЫМ КИОТСКИМ ПРОТОКОЛОМ, С ПОТЕНЦИАЛОМ ГЛОБАЛЬНОГО ПОТЕПЛЕНИЯ (GWP) = 1975. Українська Згідно норм 842/EC/2006 стаття 7(1) НЕ ВИПУСКАЙТЕ R410A В АТМОСФЕРУ: R410A - ФТОРОВМІСНИЙ ПАРНИКОВИЙ ГАЗ, ЩО ПІДПАДАЄ ПІД ДІЮ КІОТСЬКОГО ПРОТОКОЛУ, З ПОТЕНЦІАЛОМ ГЛОБАЛЬНОГО ПОТЕПЛІННЯ (GWP) = 1975. 141
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21

Panasonic S125PT1E5 Handleiding

Type
Handleiding