DESCRIPTION
Series 327 with redundant valve operators are direct operated
3/2 solenoid valves of the balanced poppet construction type. The
body material is brass or stainless steel. Solenoid details are on
I & M sheet IM1047-2.
INSTALLATION
ASCO Numatics components are intended to be used only
within the technical characteristics as specified on the nameplate.
Changes to the equipment are only allowed after consulting the
manufacturer or its representative. Before installation depres-
surise the piping system and clean internally. The equipment
may be mounted in any position.
The pipe connections have to be in accordance with the size
indicated on the nameplate and fitted accordingly.
CAUTION:
• Reducingtheconnectionsmaycauseimproperoperationor
malfunctioning.
• Fortheprotectionoftheequipmentinstallastrainerorlter
suitable for the service involved in the inlet side as close to
the product as possible.
• Iftape,paste,sprayor a similarlubricant is used when
tightening,avoidparticlesenteringthesystem.
• Usepropertoolsandlocatewrenchesascloseaspossible
to the connection point.
• Toavoiddamagetotheequipment,DONOTOVERTIGHTEN
pipe connections.
• Donotusevalveorsolenoidasalever.
Thepipeconnectionsshouldnotapplyanyforce,torqueor
strain to the product.
ELECTRICAL CONNECTION
Incaseofelectricalconnections,theyareonlytobemadeby
trained personnel and have to be in accordance with the local
regulations and standards.
CAUTION:
• Turnoffelectricalpowersupplyandde-energisetheelectrical
circuit and voltage carrying parts before starting work.
• Allelectrical screw terminals must beproperly tightened
according to the standards before putting into service.
• Dependentuponthevoltageelectricalcomponentsmustbe
provided with an earth connection and satisfy local regulations
and standards.
The equipment can have one of the following electrical terminals:
• Spadeplug connectionsaccording toISO-4400 (when
correctly installed this connection provides lP-65 protection).
• Embeddedscrewterminalsin metal enclosure with cable
gland.
• Flyingleadsorcables.
PUTTING INTO SERVICE
Beforepressurising the system, rst carry-out an electrical
test. In caseofsolenoid valves,energise thecoilafewtimes
and notice a muffled click signifying the solenoid operation and
nature of the equipment used. The exact determination of the
sound level can only be carried out by the user having the valve
installed in his system.
SERVICE
Most of the solenoid valves are equipped with coils for con-
tinuous duty service. To prevent the possibility of personal or
property damage do not touch the solenoid which can become
hot under normal operation conditions. If the solenoid valve is
easilyaccessible,theinstallermustprovideprotectionpreventing
accidental contact.
SOUND EMISSION
Theemissionofsounddependsontheapplication,mediumand
nature of the equipment used. The exact determination of the
sound level can only be carried out by the user having the valve
installed in his system.
MAINTENANCE
Maintenance of ASCO Numatics products is dependent on service
conditions.Periodiccleaningisrecommended,thetimingofwhich
willdependonthemediaandserviceconditions.Duringservicing,
components should be examined for excessive wear. A complete
set of internal parts is available as a spare parts kit. If a problem
occurs during installation/maintenance or in case of doubt please
contact ASCO Numatics or authorised representatives.
VALVE DISASSEMBLY (2x)
Disassembleinan orderly fashion. Pay carefulattention to
exploded views provided for identification of parts.
1. Unscrew solenoid base sub-assembly and remove its O-ring.
2. Removetopspring.
3. Pulloutcoresub-assembly.Removegasket.
4. All parts are now accessible for cleaning or replacement.
VALVE REASSEMBLY (2x)
Reassemblein reverseorder of disassemblypayingcareful
attention to exploded views provided for identification and
placement of parts.
1. NOTE:Lubricateallgaskets/O-ringswithhighqualitysilicone
grease.
2. Snap gasket into the groove of the core sub-assembly
(payattentiontothecorrectsize).
3. Place core sub-assembly into body cavity and push it gently
down until the gasket just seals in the cavity of the body.
4. ReplacesolenoidbaseO-ringandtopspring(placeclosed
end on top).
5. Replacesolenoidbasesub-assemblyandtorqueaccording
to torque chart. This will also push the core sub-assembly
into its correct position.
A separate Declaration of Incorporation relating to EEC-
Directive 89/392/EEC Annex II B is available on request.
Please provide acknowledgement number and serial numbers
of products concerned. This product complies with the
essential requirements of the EMC-Directive 89/336/EEC
and amendments as well as the 73/23/EEC + 93/68/EEC Low
Voltage Directives. A separate Declaration of Conformity is
available on request.
DESCRIPTION
Lesvannesdelasérie327équipéesd’opérateursdevannesre-
dondantsfontpartiedelagammedesélectrovannesàcommande
directe3/2dutypedeconstructionàclapetéquilibré.Lecorps
estenlaitonouenacierinoxydable.Lesdétailsconcernantle
solénoïdesetrouventsurlafeuilleI&MIM1047-2
MONTAGE
Lescomposants ASCONumatics sont conçus pour les do-
mainesdefonctionnementindiqués sur la plaque signalétique
ouladocumentation.Aucunemodicationnepeutêtreréalisée
surlematérielsans l’accord préalabledu fabricantoude son
représentant.Avantdeprocéderaumontage,dépressuriserles
canalisationseteffectuerunnettoyageinterne.Lesélectrovannes
peuventêtremontédansn’importequelleposition.
Ladimensiondestuyauteriesdoitcorrespondreauraccordement
indiquésurlecorps,l’étiquetteoulanotice.
ATTENTION:
• Unerestrictiondestuyauteriespeutentraînerdesdysfonc-
tionnements.
• Andeprotégerlematériel,installerunecrépineouunltre
adéquatenamont,aussiprèsquepossibleduproduit.
• Encasd’utilisationderuban,pâte,aérosolouunlubriantlors
duserrage,veillezàcequ’aucuncorpsétrangernepénétre
dans le circuit.
• Utiliserunoutillageappropriéetplacerlesclésaussiprès
que possible du point de raccordement.
• And’évitertoutedétérioration,NEPASTROPSERRERles
raccords des tuyauteries.
• Nepasseservirdelavanneoudelatêtemagnétiquecomme
d’unlevier.
Lestubesderaccordementnedevrontexerceraucuneffort,
couple ou contrainte sur le produit.
RACCORDEMENT ÉLECTRIQUE
Leraccordement électriquedoit être réalisé par un personnel
qualiéetselonlesnormesetrèglementslocaux.
ATTENTION:
• Avanttouteintervention,couperl’alimentationélectriquepour
mettre hors tension les composants.
• Toutes lesbornesàvisdoiventêtreserréescorrectement
avant la mise en service.
• Selonlatension,lescomposantsélectriquesdoiventêtremis
àlaterreconformémentauxnormesetrèglementslocaux.
Selonlescas,leraccordementélectriques’effectuepar:
• ConnecteursdébrochablesISO-4400(avecdegrédeprotec-
tionIP-65lorsqueleraccordementestcorrectementeffectué).
• Bornesàvissolidairesdubobinage,sousboîtierenmétal
avecpresse-étoupe.
• Filsoucâblessolidairesdelabobine.
MISE EN SERVICE
Avant demettre le circuit sous pression, effectuer un essai
électrique.Danslecasd’électrovannes,mettrelabobinesous
tensionplusieurs fois et écouter le clicsourd quisignale le
fonctionnementde la tête magnétique. L’utilisateurnepourra
détermineravecprécisionleniveausonoreémisqu’aprèsavoir
montélecomposantsurl’installation.
FONCTIONNEMENT
Laplupartdesélectrovannescomportentdesbobinagesprévus
pourmisesoustensionpermanente.Pourévitertoutebrûlure,ne
pastoucherlatêtemagnétiquequi,enfonctionnementnormal
etenpermanencesoustension,peutatteindreunetempérature
élevée.Sil’électrovanneestfacilementaccessible,l’installateur
doitprévoiruneprotectionempêchanttoutcontactaccidentel.
BRUIT DE FONCTIONNEMENT
Lebruitdefonctionnementvarieselonl’utilisation,leuideet
letypedematérielemployé.L’utilisateurnepourradéterminer
avecprécisionleniveausonoreémisqu’aprèsavoirmontéle
composantsurl’installation.
ENTRETIEN
L’entretiennécessaireauxproduitsASCONumaticsvarieavec
leursconditionsd’utilisation.Ilestsouhaitabledeprocéderàun
nettoyagepériodiquedontl’intervallevariesuivantlanaturedu
uide,lesconditionsdefonctionnementetlemilieuambiant.Lors
del’intervention,lescomposants doivent être examinéspour
détectertouteusureexcessive.Unensembledepiècesinternes
estproposéenpiècesderechangepourprocéderàlaréfection.
Encasdeproblèmelorsdumontage/entretienouencasdedoute,
veuillezcontacterASCONumaticsousesreprésentantsofciels.
DEMONTAGE DE LA VANNE (2x)
Démonterdefaçonméthodique.Suivezattentivementlesvues
enéclatéfourniesdanslapochetteetdestinéesàl’identication
despièces.
1. Dévisserlabasedusolénoïdeetôtersonjointd’étanchéité.
2. Ôterleressortsupérieur.
3. Extrairelesous-ensembledenoyau.Ôterlejointd’étanchéité.
4. Vouspouvezdèsàprésentnettoyerouremplacertoutesles
pièces.
REMONTAGE DE LA VANNE (2x)
Remonterensensinverse.
1. NOTE:Lubrier tousles joints d’étanchéité/jointstoriques
avecdelagraissesiliconedehautequalité.
2. Encliqueterlejointd’étanchéitédanslarainuredusous-en-
sembledenoyau(veilleràcequelataillecorresponde).
3. Placerlesous-ensembledenoyaudanslacavitéducorps
etlefairedescendredélicatementenlepoussantjusqu’au
momentoùlejoint d’étanchéité ferme hermétiquement la
cavitéducorps.
4. Remplacer le joint d’étanchéitéde labase du solénoïde
etleressortsupérieur(placeruneextrémitéferméesurle
sommet).
5. Remplacerle sous-ensemblede la base du solénoïde et
raccorderensuivantleschémadecouple.Lesous-ensemble
denoyauseraégalementpoussédanssapositioncorrecte.
Conformément à la directive CEE 89/392/CEE Annexe II B,
une Déclaration d’incorporation peut être fournie sur
demande. Veuillez nous indiquer le numéro d’accusé de
réception (AR) et les références ou codes des produits
concernés. Ce produit est conforme aux exigences
essentielles de la Directive 89/336/CEE sur la Compatibilité
Electromagnétique, et amendements et les directives
Basse Tension 73/23/CEE + 93/68/CEE. Une déclaration de
conformité peut être fournie sur simple demande.
BESCHREIBUNG
BeiderBaureihe327mitredundantenVentilbetätigungsvorrich-
tungenhandeltes sich umdirektbetätigte 3/2-Wege-Magnet-
ventileder Konstruktionsweisemit“entlastetemVentilkolben”.
DasGehäusebesteht ausMessing oder rostfreiem Stahl.
DetaillierteInformationenzudiesemMagnetventilsindaufdem
I&M-DatenblattIM1047-2zunden.
EINBAU
DieASCONumatics-Komponentendürfennurinnerhalbderauf
denTypenschildern angegebenen Daten eingesetztwerden.
VeränderungenandenProduktensindnurnachRücksprache
mitASCONumaticszulässig.VordemEinbauderVentilemuß
dasRohrleitungssystemdrucklosgeschaltetundinnengereinigt
werden.DieEinbaulagederProdukteistgenerellbeliebig.
DieRohranschlüssesolltenentsprechenddenGrößenangaben
aufdenTypenschildern mit handelsüblichenVerschraubungen
durchgeführtwerden.
VORSICHT:
• EineReduzierungderAnschlüssekannzuLeistungs-und
Funktionsminderungenführen.
• ZumSchutzderVentilesolltenfürdieBetriebsbedingungen
geeigneteSchmutzfängeroderFiltersodichtwiemöglichin
denVentileingangintegriertwerden.
• BeiAbdichtungamGewindeistdaraufzuachten,daßkein
DichtungsmaterialindieRohrleitungoderdasVentilgelangt.
• ZumEinbau darf nur geeignetesWerkzeugverwendet
werden,das so nahewie möglicham Anschlußpunkt
anzusetzen ist.
• Um eine Beschädigungder Produkte zu vermeiden, ist
daraufzuachten,daßdieRohranschlüsseNICHTZUSTARK
ANGEZOGENwerden.
• SpuleundFührungsrohrvonVentilendürfennichtalsGe-
genhalter benutzt werden.
DieRohranschlüssesolltenuchtenunddürfenkeineSpan-
nungenaufdasVentilübertragen.
ELEKTRISCHER ANSCHLUSS
DerelektrischeAnschlußistvonFachpersonalentsprechendden
geltendenVDE-undCEE-Bestimmungenauszuführen.
VORSICHT:
• VorBeginnderArbeitenistsicherzustellen,daßalleelektri-
schenLeitungenundNetzteilespannungslosgeschaltetsind.
• AlleAnschlußklemmensindnachBeendigungderArbeiten
vorschriftsmäßigentsprechend den geltenden Normen
anzuziehen.
• JenachSpannungsbereichmußdasVentilnachdengelten-
denBestimmungenundNormeneinenSchutzleiteranschluß
erhalten.
DerMagnetantrieb kann je nachBauart folgende elektrische
Anschlüsseaufweisen:
• FlachsteckeranschlüssegemäßISO-4400(beiordnungsge-
mäßerMontageistSchutzartlP-65gewährleistet).
• AnschlüsseinnerhalbeinesMetallgehäusesmittelsSchraub-
klemmen.KabeleinführunginsGehäusemitVerschraubung.
• EingegosseneKabelenden.
INBETRIEBNAHME
VorDruckbeaufaufschlagungdesProduktessollteeineelektri-
scheFunktionsprüfungerfolgen:BeiMagnetventilenSpannung
anderMagnetspulemehrmalsein-undausschalten.Esmußein
gedämpftesKlickenzuhörensein,dasdieMagnetkopfbetätigung
unddieArtdesverwendetenGerätsanzeigt.DieexakteBestim-
mungdesGeräuschpegelskannausdiesemGrundnurdurch
diePersondurchgeführtwerden,diedasVentilindasjeweilige
System eingebaut hat.
BETRIEB
Diemeisten Magnetventile sindmit Spulen für Dauerbetrieb
ausgerüstet.ZurVermeidungvonPersonen-undSachschäden
solltejede Berührung der Magnetspule vermieden werden,
dadieseunternormalenBetriebsbedingungensehrheißwerden
kann.BeileichtzugänglichemMagnetventilsolltevomInstallateur
einSchutz vorgesehen werden, umjegliches versehentliches
Berührenzuvermeiden.
GERÄUSCHEMISSION
DieGeräuschemission hängt sehrstark vomAnwendungsfall,
demMedium,mitdenendasProduktbeaufschlagtwird,undder
ArtdesverwendetenProduktesab.DieexakteBestimmungdes
GeräuschpegelskannausdiesemGrundnurdurchdiePerson
durchgeführt werden, die dasVentilin das jeweilige System
eingebaut hat.
WARTUNG
DieWartung hängtvonden Betriebsbedingungenab. Es wird
empfohlen,dasProduktregelmäßigzureinigen,wobeisichdie
ZeitabständenachdemMediumunddenBetriebsbedingungen
richten.WährendderWartung sollten die Komponentenauf
übermäßigenVerschleißüberprüftwerden.FürdieÜberholung
derASCONumatics-ProduktesindkompletteSätzemitinternen
Teilen alsErsatzteilsätzeerhältlich.TretenSchwierigkeitenbei
Einbau,BetrieboderWartungaufsowiebeiUnklarheiten,istmit
ASCONumaticsRücksprachezuhalten.
ZERLEGUNG DES VENTILS (2x)
DasVentilmußinderangegebenenReihenfolgezerlegtwerden.
DabeisinddieTeileexaktanhanddermitgeliefertenExplosions-
zeichnungen zu identifizieren.
1. Haltemutterlösen undentsprechenden Dichtungsring
entfernen.
2. ObereFederentfernen.
3. Magnetankerbaugruppeherausziehen.Dichtungentfernen.
4. NunsindalleTeile,diegereinigtoderausgetauschtwerden
müssen,leichtzugänglich.
ZUSAMMENBAU DES VENTILS (2x)
Ventil in der umgekehrtenReihenfolgewie bei der Zerlegung
zusammenbauen.DabeisinddieTeileanhandderExplosions-
zeichnungen zu identifizieren und anzuordnen.
1. HINWEIS:AlleDichtungen/Dichtungsringesindmithochwer-
tigem Silikonfett zu schmieren.
2. DichtungindieRilleanderMagnetankerbaugruppeeinsetzen
(aufkorrekteGrößeachten).
3. Magnetankerbaugruppein das Gehäuse einsetzen und
vorsichtignachunten schieben, so daß dieDichtung die
VertiefungimGehäusegeradeabdichtet.
4. Haltemutter-DichtungsringundobereFederwiederanbringen
(geschlossenesEndeoben).
5. HaltemutterwiedereinsetzenundentsprechenddenAngaben
imDrehmomentdiagrammanziehen.Dadurchwirdauchdie
Magnetankerbaugruppe in die korrekte Position geschoben.
Eine separate Herstellererklärung im Sinne der Richtlinie
89/392/EWG Anhang II B ist auf Anfrage erhältlich. Geben
Sie bitte für die betreffenden Produkte die Nummer der Auf-
tragsbestätigung und die Seriennummer an. Dieses Produkt
erfüllt die wesentlichen Anforderungen der EMC-Richtlinie
89/336/EWG und der entsprechenden Änderungen sowie
der LV-Richtlinien 73/23/EWG und 93/68/EWG. Eine separate
Konformitätserklärung ist auf Anfrage erhältlich.
DESCRIPCION
LaSerie 327 con operadoresde válvulasredundantes son
válvulasdesolenoide3/2deconstruccióndetipoclappetbalan-
ceadoyoperacióndirecta.Elmaterialdelcuerpoesdebronce
oaceroinoxidable.Losdetallesdelsolenoideestánenlahoja
de I & M IM1047-2.
INSTALACION
LoscomponentesASCONumaticssólodebenutilizarsedentrode
lasespecicacionestécnicasqueseespecicanensuplacade
características.Loscambiosenelequiposóloestaránpermitidos
despuésdeconsultaralfabricanteoasurepresentante.Antes
dela instalación,despresurice elsistemadetuberíasylimpie
internamente.Elequipopuedeutilizarseencualquierposición.
Lasconexionesalatuberíadebencorresponderaltamañoindi-
cado en la placa de características y ajustarse adecuadamente.
PRECAUCIÓN:
• Lareduccióndelasconexionespuedecausaroperaciones
incorrectas o defectos de funcionamiento.
• Paralaproteccióndelequiposedebeinstalarenlapartede
la entrada y tan cerca como sea posible del producto un filtro
o tamizador adecuado para el servicio.
• Siseutilizaracinta,pasta,sprayuotroslubricantesenelajus-
te,sedebeevitarqueentrenpartículasenelproducto.
• Sedebeutilizarlasherramientasadecuadasycolocarllaves
lomáscercaposibledelpuntodeconexión.
• Paraevitardañosalequipo,NOFORZARlasconexionesa
la tubería.
• Noutilizarlaválvulaoelsolenoidecomopalanca.
Lasconexionesalatuberíanoproduciránningunafuerza,
aprieteotensiónsobreelproducto.
CONEXION ELECTRICA
Encasoderequerirseconexioneseléctricas,estasseránrealiza-
dasporpersonalcualicadoydeberánadaptarsealasnormas
y regulaciones locales.
PRECAUCIÓN:
• Antesdecomenzareltrabajo,desconecteelsuministrode
energíaeléctricaydesenergiceelcircuitoelectrónicoylos
elementosportadoresdetensión.
• Todoslosterminaleseléctricosdebenestarapretadosade-
cuadamente según normas antes de su puesta en servicio.
• Segúnel voltaje,los componentes electrónicos deben
disponerdeunaconexiónatierraysatisfacerlasnormasy
regulaciones locales.
Elequipopuedetenerunodelossiguientesterminaleseléctricos:
• Conexionesdesenchufablessegún la norma ISO-4400
(cuandoseinstalacorrectamenteestaconexiónproporciona
unaprotecciónIP-65).
• Terminalesatornilladosempotradosencarcasametálicacon
pasacables.
• Salidadecables.
PUESTA EN MARCHA
Sedebe efectuar una prueba eléctricaantes de someter a
presiónelsistema.Enel caso de las válvulas de solenoide,
pongatensiónen la bobinaunas cuantas vecesy escucheel
clic que indica el funcionamiento del solenoide. Una determina-
ciónexactadelnivelderuidosolamentesepuedellevaracabopor
elusuarioquedispongalaválvulainstaladaensusistema.
SERVICIO
Lamayorpartedelasválvulassolenoidessesuministranconbo-
binas para un servicio continuo. Con el fin de evitar la posibilidad
dedañospersonalesomaterialesnosedebetocarelsolenoide,
ya que puede haberse calentado en condiciones normales de
trabajo.Silaelectroválvulaesdefácilacceso,elinstaladordebe
preverunaprotecciónqueimpidacualquiercontactoaccidental.
EMISION DE RUIDOS
Laemisiónderuidosdependedelaaplicación,medioynatu-
ralezadelequipoutilizado.Unadeterminaciónexactadelnivel
de ruido solamente se puede llevar a cabo por el usuario que
dispongalaválvulainstaladaensusistema.
MANTENIMIENTO
ElmantenimientodelosproductosASCONumaticsdependede
lascondicionesdeservicio.Serecomiendaunalimpiezaper-
dica,dependiendodelascondicionesdelmedioydelservicio.
Duranteelservicio,loscomponentesdebenserexaminadospor
si hubiera desgastes excesivos. Se dispone de un juego completo
de partes internas como recambio. Si ocurriera un problema
durantelainstalación/mantenimientooencasodedudacontactar
con ASCO Numatics o representantes autorizados.
DESMONTAJE DE LA VÁLVULA (2x)
Desmontelaválvulaordenadamente.Presteespecialatencióna
las vistas ampliadas que se suministran para identificar las partes.
1. Desenrosquelabaseauxiliardelsolenoideyretirelajunta.
2. Retireelresortesuperior.
3. Tiredelconjuntodelnúcleo.Retirelaguarnición.
4. Ahoratendráaccesoatodaslaspiezasparasulimpiezao
sustitución.
RE-MONTAJE DE LA VÁLVULA (2x)
Vuelvaamontarlaválvulaenelordeninversodedesmontaje
prestandoespecialatenciónalasvistasampliadassuministradas
para identificar e instalar las partes.
1. NOTA:Lubriquetodaslasguarniciones/juntascongrasade
silicona de buena calidad.
2. Insertela guarnición en el surco delconjunto delnúcleo
(tengacuidadodeutilizareltamañocorrecto).
3. Coloque el conjunto del núcleo en la cavidad del cuerpo y
llévelosuavementehastaquelaguarniciónsellelacavidad
del cuerpo.
4. Vuelvaacolocarlajuntadelabasedelsolenoideyelresorte
superior(coloqueelextremocerradoenlapartesuperior).
5. Vuelvaa colocarla base auxiliar del solenoidey apriete
segúnelcuadrodeapriete.Estotambiénllevaráelconjunto
delnúcleoasuposicióncorrecta.
Se dispone, por separado y bajo demanda, de una
Declaración de Incorporación conforme a la Directiva
CEE 89/392/EEC Anexo II B. Rogamos que nos faciliten
los números de serie y de aceptación de pedido de los
productos correspondientes. Este producto cumple con
los requisitos esenciales de la Directiva CEM 89/336/CEE
y sus correspondientes modificaciones y las directivas
Baja Tensión 73/23/CEE + 93/68/CEE. Si lo desea, podemos
facilitarle una Declaración de Conformidad bajo demanda.
IM902-13-3 / pg. 1
123620-087
INSTALLATION AND MAINTENANCE INSTRUCTIONS
directoperated,highow,balancedpoppet
(redundant)1/4
INSTRUCTIONS D’INSTALLATION ET D’ENTRETIEN
àcommandedirecte,granddébit,àclapetéquilibré
(redondant)1/4
BETRIEBSANLEITUNG
direktbetätigt,hoherDurchuß,entlasteterVentilkolben
(redundant)1/4
INSTRUCCIONES DE INSTALACIÓN Y MANTENIMIENTO
mandodirecto,altoujo,vástagoequilibrado
(repetitivo)1/4
IT NL
DRAWING DESSIN ZEICHNUNG
DISEGNO DIBUJO TEKENING
DRAWING DESSIN ZEICHNUNG
DISEGNO DIBUJO TEKENING
GB
DESCRIPTION
FR
DESCRIPTION
DE
BESCHREIBUNG
ES
DESCRIPCION
IT
DESCRIZIONE
NL
BESCHRIJVING
ASCO CONTROLS BV
P.O. Box 3, 3925 ZG Scherpenzeel, The Netherlands
Tel. +31(0)33 277 79 11 - Fax +31(0)33 277 45 61 - www.asconumatics.eu
A
A
B
C
A
D
PREFIX T, 1/2 NPT
8
3
4
5
6
7
1
2
13
12
11
10
9
SERIES
327
DESCRIZIONE
Laserie327conoperatoridivalvolaridondantisonoelettrovalvole
del tipo 3/2 a comando diretto con costruzione otturatore equilibrata.
Ilcorpoè inbronzo o inacciaio inossidabile.Iparticolari della
solenoide si trovano sulla scheda I & M IM1047-2.
INSTALLAZIONE
LeelettrovalvoleASCO Numatics devonoessere utilizzate
esclusivamente rispettando le caratteristiche tecniche specificate
sullatarghetta.Variazionisulleelettrovalvolesonoammissibilisolo
dopo avere consultato il costruttore o il suo rappresentante. Prima
dell’installazione,depressurizzarei tubi e pulireinternamente.
Leelettrovalvolepossonoesseremontateintutteleposizioni.
Iraccordidevonoessereconformiallamisuraindicatasull’ap-
posita targhetta.
ATTENZIONE:
• Ridurreiraccordipuòcausareoperazionisbagliateomal-
funzionamento.
• Perproteggereilcomponenteinstallare,ilpiùvicinopossibile
allatoingresso,unltroadattoalservizio.
• Sesiusanonastro,pastasprayolubricantisimiliduranteil
serraggio,evitarechedelleparticelleentrinonelcorpodella
valvola.
• Usareattrezzatureappropriateeposizionarelechiaviilpiù
vicino possibile al punto di raccordo.
• Perevitaredanni al corpo della valvola,NON SERRARE
ECCESSIVAMENTEiraccordi.
• Nonusarelavalvolaoilsolenoidecomeunaleva.Iraccordi
nondevonoesercitarepressione,torsioneosollecitazione
sull’elettrovalvola.
ALLACCIAMENTO ELETTRICO
L’allacciamentoelettricodeveessereeffettuatoesclusivamenteda
personale specializzato e deve essere conforme alle norme locali.
ATTENZIONE:
• Primadimettereinfunzione,toglierel’alimentazioneelettrica,
diseccitare il circuito elettrico e le parti sotto tensione.
• I morsetti elettrici devonoessere correttamente avvitati
secondo le norme prima della messa in servizio.
• Le elettrovalvoledevonoessere provvistedi morsetti di
terra a seconda della tensione e delle norme di sicurezza
locali.
I piloti possono avere una delle seguenti caratteristiche elettriche:
• ConnettorialanciasecondoISO-4400(seinstallatocorretta-
mente,laclassediprotezionediquestoconnettoreèIP65).
• Morsettieraracchiusaincustodiametallica.Entratacavicon
pressacavi.
• Bobineconliocavo.
MESSA IN FUNZIONE
Primadidarepressioneallavalvola,eseguireuntestelettrico.
Eccitarelabobinadiversevoltenoanotareunoscattosmorzato
cheindicachelasolenoideèentratainfunzione.L’utentepuò
stabilire esattamente il livello del suono solo dopo aver installato
la valvola sul suo impianto.
SERVIZIO
Molte elettrovalvole sono provviste di bobine per il funzionamento
continuo.Perprevenirelapossibilitàdidanneggiarecoseopersone,
nontoccareilsolenoide.Sedifacileaccesso,l’elettrovalvoladeve
essere protetta per evitare qualsiasi contatto accidentale.
EMISSIONE SUONI
L’emissionedisuonidipendedall’applicazioneedaltipodielet-
trovalvola.L’utentepuòstabilireesattamenteillivellodelsuono
solo dopo aver installato la valvola sul suo impianto.
MANUTENZIONE
Generalmentequesti componenti non necessitano spesso
dimanutenzione.Comunque in alcuni casi è necessario fare
attenzione a depositi o ad eccessiva usura. Questi componenti
devono essere puliti periodicamente. Il tempo che intercorre tra
unapuliziael’altravariaasecondadellecondizionidifunziona-
mento. Il ciclo di durata dei componenti dipende dalle condizioni
difunzionamento.Incasodiusuraèdisponibileunsetcompleto
di parti interne per la revisione. Se si incontrano problemi durante
l’installazioneelamanutenzioneosesihannodeidubbi,consul-
tare ASCO Numatics o i suoi rappresentanti.
SMONTAGGIO DELLA VALVOLA (2x)
Smontare procedendo con ordine. Consultare attentamente gli
esplosi forniti per una corretta identificazione delle parti.
1. Svitareilgruppocannottoetoglierel’anelloditenuta.
2. Smontare la molla superiore.
3. Sfilare il sottogruppo del nucleo. Smontare la guarnizione.
4. Ora tutte le parti sono accessibili per la pulizia o la sostitu-
zione.
RIMONTAGGIO DELLA VALVOLA (2x)
Rimontareprocedendo nell’ordine inversofacendoriferimento
agli esplosi forniti per la corretta identificazione e collocazione
delle parti.
1. NOTA:Lubricare tuttele guarnizioni/anelli di tenutacon
grassoalsiliconed’altaqualità.
2. Inserire la guarnizione nella scanalatura del sottogruppo del
nucleofacendolascattare(badarechelamisurasiaquella
giusta).
3. Inserireilsottogruppodelnucleonell’aperturadelcorpoe
spingeredelicatamentenchélaguarnizionesigillal’apertura.
4. Rimontarel’anelloditenutaelamollasuperioredelgruppo
cannotto(conl’estremitàchiusainalto).
5. Rimontareilgruppocannottoeserrareconcoppiasecondo
quanto indicato nella tabella. In questo modo il sottogruppo
del nucleo viene spinto nella giusta posizione.
L’utente può richiedere al costruttore una Dichiarazione
di Conformità separata relativa alla Direttiva CEE 89/392
Allegato II B. Precisando il numero della conferma d’ordine
i numeri di serie dei prodotti. Il presente prodotto è confor-
me ai requisiti essenziali della Direttiva EMC 89/336/CEE
e successive modifiche nonché alle Direttive sulla Bassa
Tensione 73/23/CEE e 93/68/CEE. È disponibile a richiesta
una Dichiarazione di Conformità separata.
BESCHRIJVING
Afsluiters uit de 327-serie met redundante afsluiterkoppen zijn
direct werkende 3/2-magneetafsluiters met gebalanceerde schuif-
klep.Hetafsluiterhuisisvanmessingofroestvaststaal.Raadpleeg
IM1047-2 voor de details over de magneetkop.
INSTALLATIE
ASCO Numatics producten mogen uitsluitend toegepast worden
binnendeopdenaamplaataangegevenspecicaties.Wijzigin-
gen zijn alleen toegestaan na overleg met de fabrikant of haar
vertegenwoordiger.Voorhetinbouwendienthetleidingsysteem
drukloosgemaakttewordeneninwendiggereinigd.Depositie
van de afsluiter is naar keuze te bepalen.
Depijpaansluitingmoetovereenkomstigdenaamplaatgegevens
plaatsvinden.
LETOP:
• Een reductie vande aansluitingen kan tot prestatie-en
functiestoornis leiden.
• Terbeschermingvandeinternedelenwordteenlterinhet
leidingnet aanbevolen.
• Bijhetgebruikvandraadafdichtingspastaoftapemogener
geen deeltjes in het leidingwerk geraken.
• Mendientuitsluitendgeschiktgereedschapvoordemontage
te gebruiken.
• Gebruikeenzodanigkoppelvoorleidingverbindingendathet
productNIETWORDTBESCHADIGD.
• Hetproduct,debehuizingofdespoelmagnietalshefboom
worden gebruikt.
Depijpaansluitingenmogengeenkrachtenofmomentenop
het product overdragen.
ELEKTRISCHE AANSLUITING
In geval van elektrische aansluiting dient dit door vakkundig
personeel te worden uitgevoerd volgens de door de plaatselijke
overheid bepaalde richtlijnen.
LETOP:
• Voordatmenaanhetwerkbegintmoetenallespanningsvoe-
rende delen spanningsloos worden gemaakt.
• Alleaansluitklemmenmoetennahetbeëindigenvanhetwerk
volgens de juiste normen worden aangedraaid.
• Alnaargelanghetspanningsbereikmoethetproductvolgens
de geldende normen van een aarding worden voorzien.
Hetproductkandevolgendeaansluitingenhebben:
• StekeraansluitingvolgensISO-4400(bijjuistemontagewordt
de dichtheidsklasse IP-65 verkregen).
• Aansluiting in het metalenhuis d.m.v. schroefaansluiting.
Dekabeldoorvoerheefteenwartelaansluiting.
• Losseofaangegotenkabels.
IN GEBRUIK STELLEN
Voordat de druk aangesloten wordtdient een elektrische test
te worden uitgevoerd. In geval van magneetafsluiters legt men
meerdere malen spanning op de spoel aan waarbij een gedempt
“klikken” hoorbaar moet zijn bijjuistfunctioneren. De bepaling
van het geluidsniveau kan pas uitgevoerd worden nadat de
afsluiter is ingebouwd.
GEBRUIK
Demeestemagneetafsluiterszijnuitgevoerdmetspoelenvoor
continu gebruik. Om persoonlijk letsel en schade door aanraking
van het spoelhuis te voorkomen dient men het aanraken te
vermijden,omdat bijlangdurige inschakelingde spoel of het
spoelhuis heet kan worden. In voorkomende gevallen dient men
de spoel af te schermen voor aanraking.
GELUIDSEMISSIE
Degeluidsemissie hangt sterk afvande toepassing en het
gebruiktemedium.Debepalingvanhetgeluidsniveaukanpas
uitgevoerd worden nadat de afsluiter is ingebouwd.
ONDERHOUD
Hetonderhoudaandeafsluitersisafhankelijkvandebedrijfsom-
standigheden.Weradenuaanomhetproductregelmatigtereini-
gen,inintervallendieafhankelijkzijnvanhetmediumendemate
van onderhoud. Controleer tijdens het onderhoud of onderdelen
zijn versleten. In geval van slijtage zijn reserveonderdelensets
beschikbaar om een inwendige revisie uit te voeren. In geval van
problemenofalseronduidelijkhedentijdensmontage,gebruikof
onderhoudoptreden,dandientmenzichtotASCONumaticsof
haar vertegenwoordiger te wenden.
DEMONTAGE (2x)
Neemdeafsluiteropeenordelijkewijzeuitelkaar.Raadpleeg
daarbij de montagetekeningen die de afzonderlijke onderdelen
benoemen.
1. Schroef de kopstuk/deksel-combinatie los en verwijder diens
O-ring.
2. Verwijderdebovensteveer.
3. Trekdeplunjereruit.Verwijderdeafdichting.
4. Alle delen zijn nu toegankelijk voor reiniging of vervanging.
MONTAGE (2x)
Monteer alle delen in omgekeerde volgorde als aangegeven is
bijdemontage,letdaarbijwelopdemontagetekeningvoorde
juiste plaatsing van de onderdelen.
1. OPMERKING:Vetalleafdichtingen/O-ringeninmethoog-
waardig siliconenvet.
2. Schuifdeafdichtingoverdeplunjertotindegroef(gebruik
het juiste formaat).
3. Plaats de plunjer in de opening in het afsluiterhuis en druk
de plunjer vervolgens omlaag tot de afdichting deze opening
net helemaal afsluit.
4. Plaats de O-ring van de kopstuk/deksel-combinatie en de
bovensteveerweerterug(methetspitstoelopendeuiteinde
naar boven).
5. Monteer de kopstuk/deksel-combinatie en draai deze met het
juisteaandraaimomentvast.Hierdoorwordtookdeplunjer
in de juiste positie geduwd.
Een aparte fabrikantenverklaring van inbouw, in de zin van
EU-richtlijn 89/392/EEG aanhangsel II B, is op aanvraag
verkrijgbaar. Vermeld bij aanvraag a.u.b. het orderbevesti-
gingsnummer en het serienummer. Dit product voldoet aan
de fundamentele voorschriften van EMC-richtlijn 89/336/EEG,
LS-richtlijn 73/23/EEG + 93/68/EEG en de bijbehorende wijzi-
gingen. Een afzonderlijke verklaring van overeenstemming
is op verzoek verkrijgbaar.
1. Coverassembly(2x)
2. Retainingclip(2x)
3. Washer,spring(2x)
4. Yoke(2x)
5. Coil(2x)
6. Housingassembly(2x)
7. Gasket,housingassy.(2x)
8. Sol.basesub-assy(2x)
9. Gasket,sol.basesub-as-
sy(2x)
10. Topspring(2x)
11. Core/insertsub-assy(2x)
12. Gasket,insert(2x)
13. Body,sub-assembly
1. Montageducouvercle(2x)
2. Clipdemaintien(2x)
3. Rondelleélastique,ressort(2x)
4. Culasse(2x)
5. Bobine(2x)
6. Montageduboîtier(2x)
7. Jointd’étanchéité,montage
duboîtier(2x)
8. Sous-ensemble de la base
dusol.(2x)
9. Jointd’étanchéité,sous
ensemble de la base du
sol.(2x)
10. Ressortsupérieur(2x)
11. Sous-ensemble noyau/
piècesd’insertion(2x)
12. Jointd’étanchéité,pièce
d’insertion(2x)
13. Corps,sous-ensemble
1. Deckelbaugruppe(2x)
2. Klammerhalterung(2x)
3. Federscheibe(2x)
4. Joch(2x)
5. Spule(2x)
6. Gehäusebaugruppe(2x)
7. Dichtung,Gehäusebau-
gruppe(2x)
8. Haltemutter(2x)
9. Dichtung,Haltemutter(2x)
10. ObereFeder(2x)
11. Magnetanker/Einsatzbau-
gruppe(2x)
12. Dichtung,Einsatz(2x)
13. Gehäuseunterbaugruppe
1. Montajecubierta(2x)
2. Clipdesujeción(2x)
3. Arandela,resorte(2x)
4. Yugo(2x)
5. Bobina(2x)
6. Montajecapotmetálico(2x)
7. Guarnición,montajecapot
metálico(2x)
8. Base auxiliar del solenoi-
de(2x)
9. Guarnición,baseauxiliar
delsolenoide(2x)
10. Resortesuperior(2x)
11. Núcleo/subconjunto pieza
inserción(2x)
12. Guarnición,piezainser-
ción(2x)
13. Cuerpo,subconjunto
1. Gruppocopertura(2x)
2. Clipdissaggio(2x)
3. Ghiera(2x)
4. Brida(2x)
5. Bobina(2x)
6. Gruppoinvolucro(2x)
7. Guarnizione,gruppoinvolu-
cro(2x)
8. Gruppocannottosolenoi-
de(2x)
9. Guarnizionegruppocannotto
solenoide(2x)
10. Mollasuperiore(2x)
11. Sottogruppo nucleo/inser-
to(2x)
12. Guarnizione,inserto(2x)
13. Corpo,sottogruppo
1. Deksel(2x)
2. Bevestigingsclip(2x)
3. Veerring(2x)
4. Juk(2x)
5. Spoel(2x)
6. Spoelhuis(2x)
7. Afdichting,spoelhuis(2x)
8. Kopstuk/deksel-combinatie(2x)
9. Afdichting,kopstuk/dek-
sel-combinatie(2x)
10. Bovensteveer(2x)
11. Plunjer/inzetstuk-combinatie(2x)
12. Afdichting,inzetstuk(2x)
13. Huis,combinatie
IM902-13-3 / pg. 2
123620-087
ISTRUZIONI DI INSTALLAZIONE E MANUTENZIONE
acomandodiretto,grandeportata,otturatore
equilibrato 1/4
ALGEMENE INSTALLATIE- EN ONDERHOUDSINSTRUCTIES
directwerkend,grotedoorstroomfactor,gebalanceerde
klep(redundant)1/4
TORQUE CHART
A 1,5±0,2 12±2
B 0,5±0,1 4±1
C 2±0,2 17±2
D 30±3 260±25
ITEMS NEWTON.METRES INCH.POUNDS
GB
¬ Supplied in spare part kit
FR
¬Livréesenpochettederechange
DE
¬EnthaltenimErsatzteilsatz
ES
¬ Incluido en Kit de recambio
IT
¬DisponibilenelKitpartidiricambio
NL
¬Geleverdinvervangingsset
Ø
Catalogue number
Code électrovanne
Katalognummer
Código de la electrovalvula
Codice elettrovalvola
Katalogus nummer
Spare part kit
Code pochette de rechange
Ersatzteilsatz
Código del kit de recambio
Kit parti di ricambio
Vervangingsset
1/4
EMG327A051
WSEMG327A052
EMG327A061
WSEMG327A062
C133-818
C133-819
C133-820
C133-821
1
2
3

Documenttranscriptie

INSTALLATION AND MAINTENANCE INSTRUCTIONS direct operated, high flow, balanced poppet (redundant) 1/4     GB DESCRIPTION Series 327 with redundant valve operators are direct operated 3/2 solenoid valves of the balanced poppet construction type. The body material is brass or stainless steel. Solenoid details are on I & M sheet IM1047-2. SOUND EMISSION The emission of sound depends on the application, medium and nature of the equipment used. The exact determination of the sound level can only be carried out by the user having the valve installed in his system. INSTALLATION ASCO Numatics components are intended to be used only within the technical characteristics as specified on the nameplate. Changes to the equipment are only allowed after consulting the manufacturer or its representative. Before installation depressurise the piping system and clean internally. The equipment may be mounted in any position. MAINTENANCE Maintenance of ASCO Numatics products is dependent on service conditions. Periodic cleaning is recommended, the timing of which will depend on the media and service conditions. During servicing, components should be examined for excessive wear. A complete set of internal parts is available as a spare parts kit. If a problem occurs during installation/maintenance or in case of doubt please contact ASCO Numatics or authorised representatives. The pipe connections have to be in accordance with the size indicated on the nameplate and fitted accordingly. CAUTION: • Reducing the connections may cause improper operation or malfunctioning. • For the protection of the equipment install a strainer or filter suitable for the service involved in the inlet side as close to the product as possible. • If tape, paste, spray or a similar lubricant is used when tightening, avoid particles entering the system. • Use proper tools and locate wrenches as close as possible to the connection point. • To avoid damage to the equipment, DO NOT OVERTIGHTEN pipe connections. • Do not use valve or solenoid as a lever. The pipe connections should not apply any force, torque or strain to the product. ELECTRICAL CONNECTION In case of electrical connections, they are only to be made by trained personnel and have to be in accordance with the local regulations and standards. CAUTION: • Turn off electrical power supply and de-energise the electrical circuit and voltage carrying parts before starting work. • All electrical screw terminals must be properly tightened according to the standards before putting into service. • Dependent upon the voltage electrical components must be provided with an earth connection and satisfy local regulations and standards. The equipment can have one of the following electrical terminals: • Spade plug connections according to ISO-4400 (when correctly installed this connection provides lP-65 protection). • Embedded screw terminals in metal enclosure with cable gland. • Flying leads or cables. VALVE DISASSEMBLY (2x) Disassemble in an orderly fashion. Pay careful attention to exploded views provided for identification of parts. 1. Unscrew solenoid base sub-assembly and remove its O-ring. 2. Remove top spring. 3. Pull out core sub-assembly. Remove gasket. 4. All parts are now accessible for cleaning or replacement. VALVE REASSEMBLY (2x) Reassemble in reverse order of disassembly paying careful attention to exploded views provided for identification and placement of parts. 1. NOTE: Lubricate all gaskets/O-rings with high quality silicone grease. 2. Snap gasket into the groove of the core sub-assembly (pay attention to the correct size). 3. Place core sub-assembly into body cavity and push it gently down until the gasket just seals in the cavity of the body. 4. Replace solenoid base O-ring and top spring (place closed end on top). 5. Replace solenoid base sub-assembly and torque according to torque chart. This will also push the core sub-assembly into its correct position. A separate Declaration of Incorporation relating to EECDirective 89/392/EEC Annex II B is available on request. Please provide acknowledgement number and serial numbers of products concerned. This product complies with the essential requirements of the EMC-Directive 89/336/EEC and amendments as well as the 73/23/EEC + 93/68/EEC Low Voltage Directives. A separate Declaration of Conformity is available on request. PUTTING INTO SERVICE Before pressurising the system, first carry-out an electrical test. In case of solenoid valves, energise the coil a few times and notice a muffled click signifying the solenoid operation and nature of the equipment used. The exact determination of the sound level can only be carried out by the user having the valve installed in his system. BETRIEBSANLEITUNG Die Rohranschlüsse sollten entsprechend den Größenangaben auf den Typenschildern mit handelsüblichen Verschraubungen durchgeführt werden. VORSICHT: • Eine Reduzierung der Anschlüsse kann zu Leistungs- und Funktionsminderungen führen. • Zum Schutz der Ventile sollten für die Betriebsbedingungen geeignete Schmutzfänger oder Filter so dicht wie möglich in den Ventileingang integriert werden. • Bei Abdichtung am Gewinde ist darauf zu achten, daß kein Dichtungsmaterial in die Rohrleitung oder das Ventil gelangt. • Zum Einbau darf nur geeignetes Werkzeug verwendet werden, das so nahe wie möglich am Anschlußpunkt anzusetzen ist. • Um eine Beschädigung der Produkte zu vermeiden, ist darauf zu achten, daß die Rohranschlüsse NICHT ZU STARK ANGEZOGEN werden. • Spule und Führungsrohr von Ventilen dürfen nicht als Gegenhalter benutzt werden. Die Rohranschlüsse sollten fluchten und dürfen keine Spannungen auf das Ventil übertragen. ELEKTRISCHER ANSCHLUSS Der elektrische Anschluß ist von Fachpersonal entsprechend den geltenden VDE- und CEE-Bestimmungen auszuführen. VORSICHT: • Vor Beginn der Arbeiten ist sicherzustellen, daß alle elektrischen Leitungen und Netzteile spannungslos geschaltet sind. • Alle Anschlußklemmen sind nach Beendigung der Arbeiten vorschriftsmäßig entsprechend den geltenden Normen anzuziehen. • Je nach Spannungsbereich muß das Ventil nach den geltenden Bestimmungen und Normen einen Schutzleiteranschluß erhalten. 123620-087 Der Magnetantrieb kann je nach Bauart folgende elektrische Anschlüsse aufweisen: • Flachsteckeranschlüsse gemäß ISO-4400 (bei ordnungsgemäßer Montage ist Schutzart lP-65 gewährleistet). • Anschlüsse innerhalb eines Metallgehäuses mittels Schraubklemmen. Kabeleinführung ins Gehäuse mit Verschraubung. • Eingegossene Kabelenden. INBETRIEBNAHME Vor Druckbeaufaufschlagung des Produktes sollte eine elektrische Funktionsprüfung erfolgen: Bei Magnetventilen Spannung an der Magnetspule mehrmals ein- und ausschalten. Es muß ein gedämpftes Klicken zu hören sein, das die Magnetkopfbetätigung und die Art des verwendeten Geräts anzeigt. Die exakte Bestimmung des Geräuschpegels kann aus diesem Grund nur durch die Person durchgeführt werden, die das Ventil in das jeweilige System eingebaut hat. IM902-13-3 / pg. 1 DESCRIPTION Les vannes de la série 327 équipées d’opérateurs de vannes redondants font partie de la gamme des électrovannes à commande directe 3/2 du type de construction à clapet équilibré. Le corps est en laiton ou en acier inoxydable. Les détails concernant le solénoïde se trouvent sur la feuille I & M IM1047-2 MONTAGE Les composants ASCO Numatics sont conçus pour les domaines de fonctionnement indiqués sur la plaque signalétique ou la documentation. Aucune modification ne peut être réalisée sur le matériel sans l’accord préalable du fabricant ou de son représentant. Avant de procéder au montage, dépressuriser les canalisations et effectuer un nettoyage interne. Les électrovannes peuvent être monté dans n’importe quelle position. La dimension des tuyauteries doit correspondre au raccordement indiqué sur le corps, l’étiquette ou la notice. ATTENTION: • Une restriction des tuyauteries peut entraîner des dysfonctionnements. • Afin de protéger le matériel, installer une crépine ou un filtre adéquat en amont, aussi près que possible du produit. • En cas d’utilisation de ruban, pâte, aérosol ou un lubrifiant lors du serrage, veillez à ce qu’aucun corps étranger ne pénétre dans le circuit. • Utiliser un outillage approprié et placer les clés aussi près que possible du point de raccordement. • Afin d’éviter toute détérioration, NE PAS TROP SERRER les raccords des tuyauteries. • Ne pas se servir de la vanne ou de la tête magnétique comme d’un levier. Les tubes de raccordement ne devront exercer aucun effort, couple ou contrainte sur le produit. RACCORDEMENT ÉLECTRIQUE Le raccordement électrique doit être réalisé par un personnel qualifié et selon les normes et règlements locaux. ATTENTION: • Avant toute intervention, couper l’alimentation électrique pour mettre hors tension les composants. • Toutes les bornes à vis doivent être serrées correctement avant la mise en service. • Selon la tension, les composants électriques doivent être mis à la terre conformément aux normes et règlements locaux. Selon les cas, le raccordement électrique s’effectue par: • Connecteurs débrochables ISO-4400 (avec degré de protection IP-65 lorsque le raccordement est correctement effectué). • Bornes à vis solidaires du bobinage, sous boîtier en métal avec presse-étoupe. • Fils ou câbles solidaires de la bobine.     FR BRUIT DE FONCTIONNEMENT Le bruit de fonctionnement varie selon l’utilisation, le fluide et le type de matériel employé. L’utilisateur ne pourra déterminer avec précision le niveau sonore émis qu’après avoir monté le composant sur l’installation. ENTRETIEN L’entretien nécessaire aux produits ASCO Numatics varie avec leurs conditions d’utilisation. Il est souhaitable de procéder à un nettoyage périodique dont l’intervalle varie suivant la nature du fluide, les conditions de fonctionnement et le milieu ambiant. Lors de l’intervention, les composants doivent être examinés pour détecter toute usure excessive. Un ensemble de pièces internes est proposé en pièces de rechange pour procéder à la réfection. En cas de problème lors du montage/entretien ou en cas de doute, veuillez contacter ASCO Numatics ou ses représentants officiels. DEMONTAGE DE LA VANNE (2x) Démonter de façon méthodique. Suivez attentivement les vues en éclaté fournies dans la pochette et destinées à l’identification des pièces. 1. Dévisser la base du solénoïde et ôter son joint d’étanchéité. 2. Ôter le ressort supérieur. 3. Extraire le sous-ensemble de noyau. Ôter le joint d’étanchéité. 4. Vous pouvez dès à présent nettoyer ou remplacer toutes les pièces. REMONTAGE DE LA VANNE (2x) Remonter en sens inverse. 1. NOTE: Lubrifier tous les joints d’étanchéité/joints toriques avec de la graisse silicone de haute qualité. 2. Encliqueter le joint d’étanchéité dans la rainure du sous-ensemble de noyau (veiller à ce que la taille corresponde). 3. Placer le sous-ensemble de noyau dans la cavité du corps et le faire descendre délicatement en le poussant jusqu’au moment où le joint d’étanchéité ferme hermétiquement la cavité du corps. 4. Remplacer le joint d’étanchéité de la base du solénoïde et le ressort supérieur (placer une extrémité fermée sur le sommet). 5. Remplacer le sous-ensemble de la base du solénoïde et raccorder en suivant le schéma de couple. Le sous-ensemble de noyau sera également poussé dans sa position correcte. Conformément à la directive CEE 89/392/CEE Annexe II B, une Déclaration d’incorporation peut être fournie sur demande. Veuillez nous indiquer le numéro d’accusé de réception (AR) et les références ou codes des produits concernés. Ce produit est conforme aux exigences essentielles de la Directive 89/336/CEE sur la Compatibilité Electromagnétique, et amendements et les directives Basse Tension 73/23/CEE + 93/68/CEE. Une déclaration de conformité peut être fournie sur simple demande. FONCTIONNEMENT La plupart des électrovannes comportent des bobinages prévus pour mise sous tension permanente. Pour éviter toute brûlure, ne pas toucher la tête magnétique qui, en fonctionnement normal et en permanence sous tension, peut atteindre une température élevée. Si l’électrovanne est facilement accessible, l’installateur doit prévoir une protection empêchant tout contact accidentel. direkt betätigt, hoher Durchfluß, entlasteter Ventilkolben (redundant) 1/4 EINBAU Die ASCO Numatics-Komponenten dürfen nur innerhalb der auf den Typenschildern angegebenen Daten eingesetzt werden. Veränderungen an den Produkten sind nur nach Rücksprache mit ASCO Numatics zulässig. Vor dem Einbau der Ventile muß das Rohrleitungssystem drucklos geschaltet und innen gereinigt werden. Die Einbaulage der Produkte ist generell beliebig. à commande directe, grand débit, à clapet équilibré (redondant) 1/4 MISE EN SERVICE Avant de mettre le circuit sous pression, effectuer un essai électrique. Dans le cas d’électrovannes, mettre la bobine sous tension plusieurs fois et écouter le clic sourd qui signale le fonctionnement de la tête magnétique. L’utilisateur ne pourra déterminer avec précision le niveau sonore émis qu’après avoir monté le composant sur l’installation. SERVICE Most of the solenoid valves are equipped with coils for continuous duty service. To prevent the possibility of personal or property damage do not touch the solenoid which can become hot under normal operation conditions. If the solenoid valve is easily accessible, the installer must provide protection preventing accidental contact. BESCHREIBUNG Bei der Baureihe 327 mit redundanten Ventilbetätigungsvorrichtungen handelt es sich um direkt betätigte 3/2-Wege-Magnetventile der Konstruktionsweise mit “entlastetem Ventilkolben”. Das Gehäuse besteht aus Messing oder rostfreiem Stahl. Detaillierte Informationen zu diesem Magnetventil sind auf dem I&M-Datenblatt IM1047-2 zu finden. INSTRUCTIONS D’INSTALLATION ET D’ENTRETIEN     DE BETRIEB Die meisten Magnetventile sind mit Spulen für Dauerbetrieb ausgerüstet. Zur Vermeidung von Personen- und Sachschäden sollte jede Berührung der Magnetspule vermieden werden, da diese unter normalen Betriebsbedingungen sehr heiß werden kann. Bei leicht zugänglichem Magnetventil sollte vom Installateur ein Schutz vorgesehen werden, um jegliches versehentliches Berühren zu vermeiden. GERÄUSCHEMISSION Die Geräuschemission hängt sehr stark vom Anwendungsfall, dem Medium, mit denen das Produkt beaufschlagt wird, und der Art des verwendeten Produktes ab. Die exakte Bestimmung des Geräuschpegels kann aus diesem Grund nur durch die Person durchgeführt werden, die das Ventil in das jeweilige System eingebaut hat. WARTUNG Die Wartung hängt von den Betriebsbedingungen ab. Es wird empfohlen, das Produkt regelmäßig zu reinigen, wobei sich die Zeitabstände nach dem Medium und den Betriebsbedingungen richten. Während der Wartung sollten die Komponenten auf übermäßigen Verschleiß überprüft werden. Für die Überholung der ASCO Numatics-Produkte sind komplette Sätze mit internen Teilen als Ersatzteilsätze erhältlich. Treten Schwierigkeiten bei Einbau, Betrieb oder Wartung auf sowie bei Unklarheiten, ist mit ASCO Numatics Rücksprache zu halten. ZERLEGUNG DES VENTILS (2x) Das Ventil muß in der angegebenen Reihenfolge zerlegt werden. Dabei sind die Teile exakt anhand der mitgelieferten Explosionszeichnungen zu identifizieren. 1. Haltemutter lösen und entsprechenden Dichtungsring entfernen. 2. Obere Feder entfernen. 3. Magnetankerbaugruppe herausziehen. Dichtung entfernen. 4. Nun sind alle Teile, die gereinigt oder ausgetauscht werden müssen, leicht zugänglich. ZUSAMMENBAU DES VENTILS (2x) Ventil in der umgekehrten Reihenfolge wie bei der Zerlegung zusammenbauen. Dabei sind die Teile anhand der Explosionszeichnungen zu identifizieren und anzuordnen. 1. HINWEIS: Alle Dichtungen/Dichtungsringe sind mit hochwertigem Silikonfett zu schmieren. 2. Dichtung in die Rille an der Magnetankerbaugruppe einsetzen (auf korrekte Größe achten). 3. Magnetankerbaugruppe in das Gehäuse einsetzen und vorsichtig nach unten schieben, so daß die Dichtung die Vertiefung im Gehäuse gerade abdichtet. 4. Haltemutter-Dichtungsring und obere Feder wieder anbringen (geschlossenes Ende oben). 5. Haltemutter wieder einsetzen und entsprechend den Angaben im Drehmomentdiagramm anziehen. Dadurch wird auch die Magnetankerbaugruppe in die korrekte Position geschoben. Eine separate Herstellererklärung im Sinne der Richtlinie 89/392/EWG Anhang II B ist auf Anfrage erhältlich. Geben Sie bitte für die betreffenden Produkte die Nummer der Auftragsbestätigung und die Seriennummer an. Dieses Produkt erfüllt die wesentlichen Anforderungen der EMC-Richtlinie 89/336/EWG und der entsprechenden Änderungen sowie der LV-Richtlinien 73/23/EWG und 93/68/EWG. Eine separate Konformitätserklärung ist auf Anfrage erhältlich. INSTRUCCIONES DE INSTALACIÓN Y MANTENIMIENTO mando directo, alto flujo, vástago equilibrado (repetitivo) 1/4 DESCRIPCION La Serie 327 con operadores de válvulas redundantes son válvulas de solenoide 3/2 de construcción de tipo clappet balanceado y operación directa. El material del cuerpo es de bronce o acero inoxidable. Los detalles del solenoide están en la hoja de I & M IM1047-2. INSTALACION Los componentes ASCO Numatics sólo deben utilizarse dentro de las especificaciones técnicas que se especifican en su placa de características. Los cambios en el equipo sólo estarán permitidos después de consultar al fabricante o a su representante. Antes de la instalación, despresurice el sistema de tuberías y limpie internamente. El equipo puede utilizarse en cualquier posición. Las conexiones a la tubería deben corresponder al tamaño indicado en la placa de características y ajustarse adecuadamente. PRECAUCIÓN: • La reducción de las conexiones puede causar operaciones incorrectas o defectos de funcionamiento. • Para la protección del equipo se debe instalar en la parte de la entrada y tan cerca como sea posible del producto un filtro o tamizador adecuado para el servicio. • Si se utilizara cinta, pasta, spray u otros lubricantes en el ajuste, se debe evitar que entren partículas en el producto. • Se debe utilizar las herramientas adecuadas y colocar llaves lo más cerca posible del punto de conexión. • Para evitar daños al equipo, NO FORZAR las conexiones a la tubería. • No utilizar la válvula o el solenoide como palanca. Las conexiones a la tubería no producirán ninguna fuerza, apriete o tensión sobre el producto. CONEXION ELECTRICA En caso de requerirse conexiones eléctricas, estas serán realizadas por personal cualificado y deberán adaptarse a las normas y regulaciones locales. PRECAUCIÓN: • Antes de comenzar el trabajo, desconecte el suministro de energía eléctrica y desenergice el circuito electrónico y los elementos portadores de tensión. • Todos los terminales eléctricos deben estar apretados adecuadamente según normas antes de su puesta en servicio. • Según el voltaje, los componentes electrónicos deben disponer de una conexión a tierra y satisfacer las normas y regulaciones locales. El equipo puede tener uno de los siguientes terminales eléctricos: • Conexiones desenchufables según la norma ISO-4400 (cuando se instala correctamente esta conexión proporciona una protección IP-65). • Terminales atornillados empotrados en carcasa metálica con pasacables. • Salida de cables. PUESTA EN MARCHA Se debe efectuar una prueba eléctrica antes de someter a presión el sistema. En el caso de las válvulas de solenoide, ponga tensión en la bobina unas cuantas veces y escuche el clic que indica el funcionamiento del solenoide. Una determinación exacta del nivel de ruido solamente se puede llevar a cabo por el usuario que disponga la válvula instalada en su sistema.     ES SERVICIO La mayor parte de las válvulas solenoides se suministran con bobinas para un servicio continuo. Con el fin de evitar la posibilidad de daños personales o materiales no se debe tocar el solenoide, ya que puede haberse calentado en condiciones normales de trabajo. Si la electroválvula es de fácil acceso, el instalador debe prever una protección que impida cualquier contacto accidental. EMISION DE RUIDOS La emisión de ruidos depende de la aplicación, medio y naturaleza del equipo utilizado. Una determinación exacta del nivel de ruido solamente se puede llevar a cabo por el usuario que disponga la válvula instalada en su sistema. MANTENIMIENTO El mantenimiento de los productos ASCO Numatics depende de las condiciones de servicio. Se recomienda una limpieza periódica, dependiendo de las condiciones del medio y del servicio. Durante el servicio, los componentes deben ser examinados por si hubiera desgastes excesivos. Se dispone de un juego completo de partes internas como recambio. Si ocurriera un problema durante la instalación/mantenimiento o en caso de duda contactar con ASCO Numatics o representantes autorizados. DESMONTAJE DE LA VÁLVULA (2x) Desmonte la válvula ordenadamente. Preste especial atención a las vistas ampliadas que se suministran para identificar las partes. 1. Desenrosque la base auxiliar del solenoide y retire la junta. 2. Retire el resorte superior. 3. Tire del conjunto del núcleo. Retire la guarnición. 4. Ahora tendrá acceso a todas las piezas para su limpieza o sustitución. RE-MONTAJE DE LA VÁLVULA (2x) Vuelva a montar la válvula en el orden inverso de desmontaje prestando especial atención a las vistas ampliadas suministradas para identificar e instalar las partes. 1. NOTA: Lubrique todas las guarniciones/juntas con grasa de silicona de buena calidad. 2. Inserte la guarnición en el surco del conjunto del núcleo (tenga cuidado de utilizar el tamaño correcto). 3. Coloque el conjunto del núcleo en la cavidad del cuerpo y llévelo suavemente hasta que la guarnición selle la cavidad del cuerpo. 4. Vuelva a colocar la junta de la base del solenoide y el resorte superior (coloque el extremo cerrado en la parte superior). 5. Vuelva a colocar la base auxiliar del solenoide y apriete según el cuadro de apriete. Esto también llevará el conjunto del núcleo a su posición correcta. Se dispone, por separado y bajo demanda, de una Declaración de Incorporación conforme a la Directiva CEE 89/392/EEC Anexo II B. Rogamos que nos faciliten los números de serie y de aceptación de pedido de los productos correspondientes. Este producto cumple con los requisitos esenciales de la Directiva CEM 89/336/CEE y sus correspondientes modificaciones y las directivas Baja Tensión 73/23/CEE + 93/68/CEE. Si lo desea, podemos facilitarle una Declaración de Conformidad bajo demanda. ASCO CONTROLS BV P.O. Box 3, 3925 ZG Scherpenzeel, The Netherlands Tel. +31(0)33 277 79 11 - Fax +31(0)33 277 45 61 - www.asconumatics.eu ISTRUZIONI DI INSTALLAZIONE E MANUTENZIONE a comando diretto, grande portata, otturatore equilibrato 1/4 DESCRIZIONE La serie 327 con operatori di valvola ridondanti sono elettrovalvole del tipo 3/2 a comando diretto con costruzione otturatore equilibrata. Il corpo è in bronzo o in acciaio inossidabile. I particolari della solenoide si trovano sulla scheda I & M IM1047-2. INSTALLAZIONE Le elettrovalvole ASCO Numatics devono essere utilizzate esclusivamente rispettando le caratteristiche tecniche specificate sulla targhetta. Variazioni sulle elettrovalvole sono ammissibili solo dopo avere consultato il costruttore o il suo rappresentante. Prima dell’installazione, depressurizzare i tubi e pulire internamente. Le elettrovalvole possono essere montate in tutte le posizioni. I raccordi devono essere conformi alla misura indicata sull’apposita targhetta. ATTENZIONE: • Ridurre i raccordi può causare operazioni sbagliate o malfunzionamento. • Per proteggere il componente installare, il più vicino possibile al lato ingresso, un filtro adatto al servizio. • Se si usano nastro, pasta spray o lubrificanti simili durante il serraggio, evitare che delle particelle entrino nel corpo della valvola. • Usare attrezzature appropriate e posizionare le chiavi il più vicino possibile al punto di raccordo. • Per evitare danni al corpo della valvola, NON SERRARE ECCESSIVAMENTE i raccordi. • Non usare la valvola o il solenoide come una leva. I raccordi non devono esercitare pressione, torsione o sollecitazione sull’elettrovalvola. ALLACCIAMENTO ELETTRICO L’allacciamento elettrico deve essere effettuato esclusivamente da personale specializzato e deve essere conforme alle norme locali. ATTENZIONE: • Prima di mettere in funzione, togliere l’alimentazione elettrica, diseccitare il circuito elettrico e le parti sotto tensione. • I morsetti elettrici devono essere correttamente avvitati secondo le norme prima della messa in servizio. • Le elettrovalvole devono essere provviste di morsetti di terra a seconda della tensione e delle norme di sicurezza locali. I piloti possono avere una delle seguenti caratteristiche elettriche: • Connettori a lancia secondo ISO-4400 (se installato correttamente, la classe di protezione di questo connettore è IP65). • Morsettiera racchiusa in custodia metallica. Entrata cavi con pressacavi. • Bobine con fili o cavo. MESSA IN FUNZIONE Prima di dare pressione alla valvola, eseguire un test elettrico. Eccitare la bobina diverse volte fino a notare uno scatto smorzato che indica che la solenoide è entrata in funzione. L’utente può stabilire esattamente il livello del suono solo dopo aver installato la valvola sul suo impianto.     DRAWING DISEGNO MANUTENZIONE Generalmente questi componenti non necessitano spesso di manutenzione. Comunque in alcuni casi è necessario fare attenzione a depositi o ad eccessiva usura. Questi componenti devono essere puliti periodicamente. Il tempo che intercorre tra una pulizia e l’altra varia a seconda delle condizioni di funzionamento. Il ciclo di durata dei componenti dipende dalle condizioni di funzionamento. In caso di usura è disponibile un set completo di parti interne per la revisione. Se si incontrano problemi durante l’installazione e la manutenzione o se si hanno dei dubbi, consultare ASCO Numatics o i suoi rappresentanti. SMONTAGGIO DELLA VALVOLA (2x) Smontare procedendo con ordine. Consultare attentamente gli esplosi forniti per una corretta identificazione delle parti. 1. Svitare il gruppo cannotto e togliere l’anello di tenuta. 2. Smontare la molla superiore. 3. Sfilare il sottogruppo del nucleo. Smontare la guarnizione. 4. Ora tutte le parti sono accessibili per la pulizia o la sostituzione. RIMONTAGGIO DELLA VALVOLA (2x) Rimontare procedendo nell’ordine inverso facendo riferimento agli esplosi forniti per la corretta identificazione e collocazione delle parti. 1. NOTA: Lubrificare tutte le guarnizioni/anelli di tenuta con grasso al silicone d’alta qualità. 2. Inserire la guarnizione nella scanalatura del sottogruppo del nucleo facendola scattare (badare che la misura sia quella giusta). 3. Inserire il sottogruppo del nucleo nell’apertura del corpo e spingere delicatamente finché la guarnizione sigilla l’apertura. 4. Rimontare l’anello di tenuta e la molla superiore del gruppo cannotto (con l’estremità chiusa in alto). 5. Rimontare il gruppo cannotto e serrare con coppia secondo quanto indicato nella tabella. In questo modo il sottogruppo del nucleo viene spinto nella giusta posizione. L’utente può richiedere al costruttore una Dichiarazione di Conformità separata relativa alla Direttiva CEE 89/392 Allegato II B. Precisando il numero della conferma d’ordine i numeri di serie dei prodotti. Il presente prodotto è conforme ai requisiti essenziali della Direttiva EMC 89/336/CEE e successive modifiche nonché alle Direttive sulla Bassa Tensione 73/23/CEE e 93/68/CEE. È disponibile a richiesta una Dichiarazione di Conformità separata. 2 DESSIN DIBUJO ONDERHOUD Het onderhoud aan de afsluiters is afhankelijk van de bedrijfsomstandigheden. We raden u aan om het product regelmatig te reinigen, in intervallen die afhankelijk zijn van het medium en de mate van onderhoud. Controleer tijdens het onderhoud of onderdelen zijn versleten. In geval van slijtage zijn reserveonderdelensets beschikbaar om een inwendige revisie uit te voeren. In geval van problemen of als er onduidelijkheden tijdens montage, gebruik of onderhoud optreden, dan dient men zich tot ASCO Numatics of haar vertegenwoordiger te wenden. INSTALLATIE ASCO Numatics producten mogen uitsluitend toegepast worden binnen de op de naamplaat aangegeven specificaties. Wijzigingen zijn alleen toegestaan na overleg met de fabrikant of haar vertegenwoordiger. Voor het inbouwen dient het leidingsysteem drukloos gemaakt te worden en inwendig gereinigd. De positie van de afsluiter is naar keuze te bepalen. De pijpaansluiting moet overeenkomstig de naamplaatgegevens plaatsvinden. LET OP: • Een reductie van de aansluitingen kan tot prestatie‑ en functiestoornis leiden. • Ter bescherming van de interne delen wordt een filter in het leidingnet aanbevolen. • Bij het gebruik van draadafdichtingspasta of tape mogen er geen deeltjes in het leidingwerk geraken. • Men dient uitsluitend geschikt gereedschap voor de montage te gebruiken. • Gebruik een zodanig koppel voor leidingverbindingen dat het product NIET WORDT BESCHADIGD. • Het product, de behuizing of de spoel mag niet als hefboom worden gebruikt. De pijpaansluitingen mogen geen krachten of momenten op het product overdragen. DEMONTAGE (2x) Neem de afsluiter op een ordelijke wijze uit elkaar. Raadpleeg daarbij de montagetekeningen die de afzonderlijke onderdelen benoemen. 1. Schroef de kopstuk/deksel-combinatie los en verwijder diens O-ring. 2. Verwijder de bovenste veer. 3. Trek de plunjer eruit. Verwijder de afdichting. 4. Alle delen zijn nu toegankelijk voor reiniging of vervanging. MONTAGE (2x) Monteer alle delen in omgekeerde volgorde als aangegeven is bij demontage, let daarbij wel op de montagetekening voor de juiste plaatsing van de onderdelen. 1. OPMERKING: Vet alle afdichtingen/O-ringen in met hoogwaardig siliconenvet. 2. Schuif de afdichting over de plunjer tot in de groef (gebruik het juiste formaat). 3. Plaats de plunjer in de opening in het afsluiterhuis en druk de plunjer vervolgens omlaag tot de afdichting deze opening net helemaal afsluit. 4. Plaats de O-ring van de kopstuk/deksel-combinatie en de bovenste veer weer terug (met het spits toelopende uiteinde naar boven). 5. Monteer de kopstuk/deksel-combinatie en draai deze met het juiste aandraaimoment vast. Hierdoor wordt ook de plunjer in de juiste positie geduwd. ELEKTRISCHE AANSLUITING In geval van elektrische aansluiting dient dit door vakkundig personeel te worden uitgevoerd volgens de door de plaatselijke overheid bepaalde richtlijnen. LET OP: • Voordat men aan het werk begint moeten alle spanningsvoerende delen spanningsloos worden gemaakt. • Alle aansluitklemmen moeten na het beëindigen van het werk volgens de juiste normen worden aangedraaid. • Al naar gelang het spanningsbereik moet het product volgens de geldende normen van een aarding worden voorzien. Een aparte fabrikantenverklaring van inbouw, in de zin van EU‑richtlijn 89/392/EEG aanhangsel II B, is op aanvraag verkrijgbaar. Vermeld bij aanvraag a.u.b. het orderbevestigingsnummer en het serienummer. Dit product voldoet aan de fundamentele voorschriften van EMC‑richtlijn 89/336/EEG, LS-richtlijn 73/23/EEG + 93/68/EEG en de bijbehorende wijzigingen. Een afzonderlijke verklaring van overeenstemming is op verzoek verkrijgbaar. Het product kan de volgende aansluitingen hebben: • Stekeraansluiting volgens ISO‑4400 (bij juiste montage wordt de dichtheidsklasse IP‑65 verkregen). • Aansluiting in het metalen huis d.m.v. schroefaansluiting. De kabeldoorvoer heeft een wartelaansluiting. • Losse of aangegoten kabels. IN GEBRUIK STELLEN Voordat de druk aangesloten wordt dient een elektrische test te worden uitgevoerd. In geval van magneetafsluiters legt men meerdere malen spanning op de spoel aan waarbij een gedempt “klikken” hoorbaar moet zijn bij juist functioneren. De bepaling van het geluidsniveau kan pas uitgevoerd worden nadat de afsluiter is ingebouwd. ZEICHNUNG TEKENING DRAWING DISEGNO 1. 2. 3. 4. 5. 6. 7. 8. 9. 1 1. 2. 3. 4. 5. 6. 7. 2 5 8. 7 A PREFIX ‘T’, 1/2 NPT 8. 9. GB ¬ Supplied in spare part kit 8 FR ¬ Livrées en pochette de rechange D DE ¬ Enthalten im Ersatzteilsatz 9 ES ¬ Incluido en Kit de recambio 10 NL ¬ Geleverd in vervangingsset IT ¬ Disponibile nel Kit parti di ricambio TORQUE CHART 11 12 1,5 ± 0,2 12 ± 2 B 0,5 ± 0,1 4 ± 1 C 2 ± 0,2 17 ± 2 30 ± 3 260 ± 25 D 123620-087 13 IM902-13-3 / pg. 2 8. A ITEMS NEWTON.METRES INCH.POUNDS Ø Catalogue number Code électrovanne Katalognummer Código de la electrovalvula Codice elettrovalvola Katalogus nummer Spare part kit Code pochette de rechange Ersatzteilsatz Código del kit de recambio Kit parti di ricambio Vervangingsset 1/4 EMG327A051 WSEMG327A052 EMG327A061 WSEMG327A062 C133-818 C133-819 C133-820 C133-821 8. 9. Joint d’étanchéité, sous ensemble de la base du sol. (2x) 10. Ressort supérieur (2x) 11. Sous-ensemble noyau/ pièces d’insertion (2x) 12. Joint d’étanchéité, pièce d’insertion (2x) 13. Corps, sous-ensemble 10. Obere Feder (2x) 11. Magnetanker/Einsatzbaugruppe (2x) 12. Dichtung, Einsatz (2x) 13. Gehäuseunterbaugruppe DESCRIPCION 9. Guarnición, base auxiliar del solenoide (2x) 10. Resorte superior (2x) 11. Núcleo/subconjunto pieza inserción (2x) 12. Guarnición, pieza inserción (2x) 13. Cuerpo, subconjunto DESCRIZIONE Gruppo copertura (2x) Clip di fissaggio (2x) Ghiera (2x) Brida (2x) Bobina (2x) Gruppo involucro (2x) Guarnizione, gruppo involucro (2x) Gruppo cannotto solenoide (2x) NL 1. 2. 3. 4. 5. 6. 7. 8. 9. Top spring (2x) Core/insert sub-assy (2x) Gasket, insert (2x) Body, sub-assembly BESCHREIBUNG Montaje cubierta (2x) Clip de sujeción (2x) Arandela, resorte (2x) Yugo (2x) Bobina (2x) Montaje capot metálico (2x) Guarnición, montaje capot metálico (2x) Base auxiliar del solenoide (2x) IT 1. 2. 3. 4. 5. 6. 7. 10. 11. 12. 13. DESCRIPTION Deckelbaugruppe (2x) Klammerhalterung (2x) Federscheibe (2x) Joch (2x) Spule (2x) Gehäusebaugruppe (2x) Dichtung, Gehäusebaugruppe (2x) Haltemutter (2x) Dichtung, Haltemutter (2x) ES 1. 2. 3. 4. 5. 6. 7. DESCRIPTION Montage du couvercle (2x) Clip de maintien (2x) Rondelle élastique, ressort (2x) Culasse (2x) Bobine (2x) Montage du boîtier (2x) Joint d’étanchéité, montage du boîtier (2x) Sous-ensemble de la base du sol. (2x) DE 1. 2. 3. 4. 5. 6. 7. C ZEICHNUNG TEKENING Cover assembly (2x) Retaining clip (2x) Washer, spring (2x) Yoke (2x) Coil (2x) Housing assembly (2x) Gasket, housing assy. (2x) Sol. base sub-assy (2x) Gasket, sol. base sub-assy (2x) FR 3 B DESSIN DIBUJO GB SERIES 327 3 6 NL GELUIDSEMISSIE De geluidsemissie hangt sterk af van de toepassing en het gebruikte medium. De bepaling van het geluidsniveau kan pas uitgevoerd worden nadat de afsluiter is ingebouwd. BESCHRIJVING Afsluiters uit de 327-serie met redundante afsluiterkoppen zijn direct werkende 3/2-magneetafsluiters met gebalanceerde schuifklep. Het afsluiterhuis is van messing of roestvast staal. Raadpleeg IM1047-2 voor de details over de magneetkop. A 4   GEBRUIK De meeste magneetafsluiters zijn uitgevoerd met spoelen voor continu gebruik. Om persoonlijk letsel en schade door aanraking van het spoelhuis te voorkomen dient men het aanraken te vermijden, omdat bij langdurige inschakeling de spoel of het spoelhuis heet kan worden. In voorkomende gevallen dient men de spoel af te schermen voor aanraking. A 1  direct werkend, grote doorstroomfactor, gebalanceerde klep (redundant) 1/4 EMISSIONE SUONI L’emissione di suoni dipende dall’applicazione e dal tipo di elettrovalvola. L’utente può stabilire esattamente il livello del suono solo dopo aver installato la valvola sul suo impianto. SERVIZIO Molte elettrovalvole sono provviste di bobine per il funzionamento continuo. Per prevenire la possibilità di danneggiare cose o persone, non toccare il solenoide. Se di facile accesso, l’elettrovalvola deve essere protetta per evitare qualsiasi contatto accidentale.  ALGEMENE INSTALLATIE- EN ONDERHOUDSINSTRUCTIES IT Guarnizione gruppo cannotto solenoide (2x) 10. Molla superiore (2x) 11. Sottogruppo nucleo/inserto (2x) 12. Guarnizione, inserto (2x) 13. Corpo, sottogruppo BESCHRIJVING Deksel (2x) Bevestigingsclip (2x) Veerring (2x) Juk (2x) Spoel (2x) Spoelhuis (2x) Afdichting, spoelhuis (2x) Kopstuk/deksel-combinatie (2x) Afdichting, kopstuk/deksel-combinatie (2x) ASCO CONTROLS BV P.O. Box 3, 3925 ZG Scherpenzeel, The Netherlands Tel. +31(0)33 277 79 11 - Fax +31(0)33 277 45 61 - www.asconumatics.eu 9. 10. 11. 12. 13. Bovenste veer (2x) Plunjer/inzetstuk-combinatie (2x) Afdichting, inzetstuk (2x) Huis, combinatie