(For municipal water we recommend the system being backwashed
every 5 days at 2am, or whenever your family is most likely to be asleep.)
1) Use the up or down arrows to set the time 12:01 PM. Once the time is changed to 12:01 PM, push the Recycle button (refer to
Figure A1) to lock it in.
2) Push and hold both arrow buttons until screen changes to read “GAL”.
3) Push Recycle button. Screen will read“FLTR”. This is set at factory and will not need to be changed. If not, use
up/down arrows to set to “FLTR".
4) Push Recycle button. Screen should read “tc”. If not, use up/down arrow buttons to set to “tc”.
5) Push Recycle button. Screen will read “NT-1”. This is the number of tanks the timer is controlling (one tank). Do not change this.
6) Push Re
6) Push Recycle button. Screen should read “DO 7”. If not, use up/down arrow buttons to set number to 7.
7) Push Recycle button. Screen should read “RT 2:00”. * If not, use up/down arrow buttons to set to 2:00.
8) Push Recycle button. Screen should read “BW 10”. If not, use up/down arrow buttons to set to 10.
9) Push Recycle button. Next screen will be “RR 10”.
10) Push Recycle button. Screen will change to time display and programming is locked in.