2 GENERAL INFORMATION
3 WHAT IS CARBON MONOXIDE
4 SYMPTOMS OF CO POISONING
5 LOCATING THE CO ALARM
6 POSITIONING THE CO ALARM (see image 2)
7 INSTALLING THE CO ALARM
8 OPERATING YOUR CO ALARM
9 TESTING YOUR CO ALARM
10 ALARM SILENCE
11 MAINTAINING YOUR CO ALARM
12 WHAT TO DO IN THE EVENT OF AN ALARM
13 TECHNICAL DATA
14 Documents / Resources
14.1 References
15 Related Posts
Smartwares FGA-13051 Battery Standalone Carbon Monoxide Alarm
Smartwares FGA-13051 Battery Standalone Carbon Monoxide
Alarm Instruction Manual
Manuals+ User Manuals Simplified.
GENERAL INFORMATION
Thank you for purchasing this Smartwares carbon monoxide alarm! Please read these instructions carefully
before using the carbon monoxide alarm. Retain this information in a safe and easily accessible place for future
use and maintenance. If you have any questions or if you are looking for additional information about your carbon
monoxide alarm or prevention of carbon monoxide poisoning, please visit our website www.smartwares.eu.
Make/model number: FGA-1305
Description: Battery powered carbon monoxide alarm with an electrochemical sensor. This apparatus
contains 3 x AA 1.5VDC LR6 Alkaline batteries and is supplied with a wall plug and screw.
Function: Carbon monoxide alarm device intended to alert persons in case of carbon monoxide to give them
time to react properly to the danger.
Scope of application: Carbon monoxide alarm for buildings with residential function.
IMPORTANT:
Caution: The alarm is designed in order to detect carbon monoxide; it cannot prevent a leakage!
Caution: The carbon monoxide alarm may not be painted or covered because this may cause loss of
functionality.
Warning: The carbon monoxide alarm must be replaced no later than 10 years after production date.
When the detector has been working for ten years, the product cannot be used anymore. Mark the replacement
date in your calendar or register for free at www.smartreminder.eu.
LED indicators (see image 1)
1. Alarm
2. Fault
3. Power
WHAT IS CARBON MONOXIDE
Carbon Monoxide (CO) is an insidious poison that is released when fuels are burnt. It is a colorless, odorless,
tasteless gas and therefore very difficult to detect with the human senses. CO kills hundreds of people each year
and injures many more. It binds to the hemoglobin in the blood and reduces the amount of oxygen being
circulated in the body. In high concentrations, CO can kill in minutes. CO is produced by the incomplete
combustion of fuels such as wood, charcoal, coal, heating oil, paraffin, petrol, natural gas, propane, butane etc.
Examples of CO sources:
Running engine in garage Gas appliances
Oil and Gas furnaces Portable generators
Wood stoves Gas or kerosene heaters
Barbecues Clogged chimneys
Wood and gas fireplaces Heating boiler
SYMPTOMS OF CO POISONING
The following symptoms may be related to CO poisoning (ppm = parts per million/ 1:1000.000):
35 ppm The maximum allowable concentration for continuous exposure for healthy adults in any 8 h
our period.
200 ppm Slight headaches, fatigue, nausea after 2-3 hours.
400 ppm Frontal headaches within 1-2 hours, life threatening after 3 hours.
800 ppm Dizziness, nausea and convulsions within 45 minutes. Unconsciousness within 2 hours. De
ath within 3 hours.
1600 ppm Headache, dizziness and nausea within 20 minutes. Death within 1 hour.
6400 ppm Headache, dizziness and nausea within 1-2 minutes.
Warning: the apparatus may not prevent the chronic effects of CO exposure or protect individuals who are at
specific risk, always pay attention to the symptoms of carbon monoxide poisoning.
LOCATING THE CO ALARM
The Carbon Monoxide alarm is designed to detect the toxic CO fumes that result from incomplete combustion,
such as those emitted from appliances, furnaces, fireplace and auto exhaust. If your dwelling is on a single story,
for minimum protection you should fit an alarm in the bedrooms or in the hallway of sleeping areas. Place it as
near to the sleeping areas as possible and ensure the alarm is audible when the bedrooms are occupied. If your
dwelling is multistory, for minimum protection place at least one alarm on each floor.
NOTE: For maximum protection an alarm should be fitted in or near every room that contains a fuel-burning
appliance such as any gas fires, central heating boilers, room heaters, water heaters, cookers, grills, etc.
CAUTION: This alarm will only indicate the presence of carbon monoxide gas at the sensor. Carbon monoxide
gas may be present in other areas.
Warning: a carbon monoxide alarm does not function as a replacement for a smoke or gas detector.
POSITIONING THE CO ALARM (see image 2)
Carbon monoxide (CO) has a similar density to warm air and, to ensure that the most effective use is made of
the detector, it should be fitted as follows: In rooms with a fuel-burning appliance CO will mix with the warm air
and rise up. Place the CO alarm on a the wall, 30-80 cm below the ceiling but above the top of any doors or
windows at a horizontal distance of minimum 150cm from the possible source of CO. It is also optional to place
the alarm on a ceiling.
In rooms where people sleep or are present for a longer period of time (bedroom, living room) place the CO
alarm at breathing height.
For more information and examples see www.smartwares.eu.
Areas to be avoided include the following:
Situations where the temperature may fall below 0°C or rise above 45°C
Any area where high levels of dusty, dirty or greasy emissions could contaminate or clog the sensor.
Behind drapes or furniture.
In the path of air discharged from a furnace / air conditioning vent or ceiling fan.
Outside the building.
Directly above a sink or cooker.
In areas where there are a lot of lampback and dust which will block up the sensor.
In too damp areas.
CAUTION: This carbon monoxide alarm is designed for indoor use only. Do not expose to rain or moisture. It will
not protect against the risk of carbon monoxide poisoning when the battery has drained. Do not open or tamper
with the alarm as this could cause malfunction and risk of electric shock.
INSTALLING THE CO ALARM
Before mounting your CO alarm, you have to attach the rating label in your own language to the detector.
In order to ensure the product is correctly installed and used, it should be installed strictly according to this user
manual or be installed by qualified professional personnel. This CO alarm is powered by a battery and requires
no additional wiring. Make sure the alarm can be heard from all sleeping areas or place several alarms.
Wall mount installation:
Having established the mounting location ensure that there is no electrical wiring or pipe work in the area
adjacent to the mounting surface.
Mark the mounting hole location, drill a ø 6mm and 40 mm depth hole in the marked position and insert the wall
plug.
Before screwing the mounting plate to the wall, remove the safety pin (see image 4). Insert the screw provided
until the screw head is 5mm from the wall. Screw on the mounting bracket, do not overtighten.
Remove the plastic sealing from the batteries and insert them into the battery compartment. Make sure that
you fit the batteries in accordance with the polarity markings (+ or -) within the battery compartment. If correctly
installed, the alarm will give a short beep. It indicates that the power supply is normally connected, and that the
indicator lights and buzzer are working normally. Assemble the alarm onto the mounting plate (see image 5).
Insert the safety pin to secure the alarm to mounting plate (see image 5.1 for location).
OPERATING YOUR CO ALARM
Normal Operation
When no carbon monoxide is present, the green “Power” indicator LED flashes every 45 seconds and is an
indication that your alarm is powered and functional.
Fault indicator
The fault indicator flashes twice with beeps when there is a fault in the sensor or circuit. Fault warning will be
given at least once every minute until the fault is eliminated. The CO alarm will not detect CO and you are not
protected. Contact Smartwares for assistance.
Alarm Condition
When the unit detects dangerous levels of CO, the alarm warning will be made. The red LED flashes 15 times
with 15 beeps in 4 seconds, rests for 3 seconds, then repeats. The alarm will not stop until CO concentration is
lower than 40 ppm.
CO-LEVEL (PPM) RESPONSE TIME (MIN)
27 +/- 3 ppm > 120 min.
55 +/- 5 ppm 60-90 min.
110 +/-10 ppm 10-40 min.
330 +/- 30 ppm < 3 min.
The alarm response time of this detector complies with EN 50291-1:2018.
Returning to normal operation
Put the detector in clean air, the alarm will terminate automatically in 6 minutes, or you can quit the alarm
condition by pressing the TEST button for 1 to 3 seconds and then release it.
Low Battery Signal / End of life warning
When the battery is empty the alarm will beep 1 times every 45 seconds and the green “Power” LED will flash
at the same time for 7 days. The battery in the apparatus needs to be replaced as soon as possible.
Battery levels:
When your CO alarm needs replacing, the unit will beep 2 times and yellow “Fault” LED indicator will flash 2
times. The apparatus must be replaced with a new CO alarm as soon as possible.
Low CO concentration warning
Prolonged exposure to low levels of CO can impair the health of vulnerable groups such as children,
pregnant women, elderly or patients.
When CO concentration is greater than 30 ppm for a duration of over 60 minutes, or when CO
concentration is greater than 40 ppm for a duration of over 40 minutes, low CO concentration warning is
given once every 3-5 minutes. The alarm indicator flashes 4 times with beeps at a lower speed.
TESTING YOUR CO ALARM
It is recommended that you test your CO alarm once a month to ensure the alarm is working correctly by pressing
and holding the test button on the front of the alarm for 2 seconds. If the detector is working properly, the alarm will
sound 5 beep tones and the red LED will flash at the same time. If there is malfunction, then the fault warning will
show.
ALARM SILENCE
Alarm silence mode only works in alarm condition.
To activate silence mode, the CO concentration must be less than 200 ppm , press and hold the TEST button
for 1 to 3 seconds until you see the alarm indicator flash with no beep. Alarm silence condition is the same as
alarm condition except the buzzer is silent temporarily. The alarm indicator still flashes.
Alarm silence condition lasts maximum 10 minutes.
Press the TEST button in alarm silence condition, and it will recover alarm condition immediately.
When the alarm silence condition ends it will recover alarm condition.
MAINTAINING YOUR CO ALARM
Your alarm will alert you to potentially hazardous CO concentrations in your home when maintained properly. To
maintain your alarm in proper working order, it is recommended that you:
Test your alarm at least once a month.
Clean your CO alarm regularly to prevent dust build up. This can be done using a vacuum cleaner with the
brush attachment once per month. Clean gently around the front grilled section and sides.
Never use cleaning solutions on your alarm. Simply wipe with a damp cloth.
Do not paint the alarm.
Do not block or cover the alarm’s venthole with paste adhesive or other things.
ATTENTION:
When scouring or stripping a wooden floor, painting, wallpapering or using adhesive or aerosol, you should
remove the carbon monoxide detector and keep it in a safe place to prevent damaging the sensor. High
concentrations of the following substances can damage the sensor, which often results in a false alarm: methane,
propane, isopropyl butane, ethylene, ethanol, alcohol, isopropyl alcohol, benzene, toluene, ethyl acetate,
hydrogen, hydrogen sulfate and sulfur dioxide. Also aerosol sprays, alcoholic products, paint, solvents, adhesive,
hair spray, aftershave, perfume and certain cleaning agents can cause damage.
WHAT TO DO IN THE EVENT OF AN ALARM
In the event the CO alarm raises an alarm:
Immediately move to fresh air outdoor or open all doors/windows to ventilate the area and allow the carbon
monoxide to disperse. Where possible turn off fuel burning appliance. Evacuate the building and do not re-
enter the premises nor move away from the open door/ window until emergency services responders have
arrived, the premises have been aired out, and your alarm remains in its normal condition. Seek medical help
immediately for anyone suffering from the symptoms of headache, drowsiness, nausea, etc. Do not use the
appliances again until they have been checked by a qualified technician and the fault located and cleared.
This product is not designed for use in a recreational vehicle or mobile home. The alarm should be installed by
a competent person.
This apparatus is designed to protect individuals from the acute effects of carbon monoxide exposure. It will not
fully safeguard individuals with specific medical conditions. If in doubt consult a medical practitioner.
The installation of this CO alarm should not be used as a substitute for proper installation, use and
maintenance of fuel burning appliances including appropriate ventilation and exhaust systems.
TECHNICAL DATA
Power Source DC 4.5V Alkaline battery type: 3 x LR6 1,5VDC
Sensor Type Electrochemical sensor
Type of Gas sensed Carbon Monoxide
Sensor Lifetime 10 Year
Alarm activation
27 +/- 3 ppm (after 120 min.)
55 +/-5 ppm (Between 60-90 min.)
110 +/- 10 ppm (Between 10-40 min.)
330 +/- 30 ppm (Within 3 minutes)
Operation Temperature
0°C~45°C (storage: -20°~50°C ±
2°C)
Ambient Humidity 0%~70% RH (storage: 0%~90% RH)
Horn Level >85 Decibels at 3 meter
For indoor use only.
Please read manual before use, and store it carefully for future use and maintenance.
For DoC go to: www.smartwares.eu/doc and follow instructions.
Condition LED Sound
Normal operation Green LED flashes every 45 secon
ds None
Testing Red LED flashes rapidly 5 beeps
Alarm Red LED flashes 15 times in 4 seco
nds. Rest 3 seconds, then repeats
15 beeps in 4
seconds, rest 3 seconds, then repe
ats
Malfunction Yellow LED flashes 2 times every 1
1 seconds 2 beeps every 11 seconds
Low battery signal Yellow LED flashes every 45 secon
ds 1 beep every 45 seconds
End of life Yellow LED flashes 2 times, END is
shown on display 2 beeps every 60 seconds
Documents / Resources
Smartwares FGA-13051 Battery Standalone Carbon Monoxide Alarm [pdf] Instruction Man
ual
FGA-13051 Battery Standalone Carbon Monoxide Alarm, FGA-13051, Battery Standalone
Carbon Monoxide Alarm, Carbon Monoxide Alarm, Monoxide Alarm
References
Receive a Smartreminder for free | Test, clean & replace your smoke detectors | Smartwares
Smartwares - Alles voor een veilig en een comfortabel huis!
Smartwares - Alles voor een veilig en een comfortabel huis!
Smartwares | Declaration of Conformity
Manuals+,
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

Smartwares FGA-13051 Battery Standalone Carbon Monoxide Alarm Handleiding

Categorie
Koolmonoxide (CO) detectoren
Type
Handleiding