Yamaha CL5 Handleiding

Categorie
Audiomixers
Type
Handleiding

Deze handleiding is ook geschikt voor

EN
V1.7 Supplementary Manual
This supplementary manual explains mainly the functions that have been added or changed in
CL5/CL3/CL1 firmware V1.6 and V1.7.
Use it in conjunction with the CL5/CL3/CL1 Owner’s Manual and Reference Manual.
Contents
V1.7 Supplementary Manual
2
Contents
SELECTED CHANNEL section ...................................................... 3
Improved gain indication......................................................................................... 3
Improved HPF indication ......................................................................................... 4
Centralogic section ................................................................... 4
Improved DCA group indication .............................................................................. 4
Input channels .......................................................................... 5
Additional head amp setting functions when changing the input patching.............. 5
Grouping and linking ............................................................... 7
Improved display of DCA group / MUTE group names............................................. 7
Added functions for DCA groups ............................................................................. 8
Improvements in channel link display ...................................................................... 9
Monitor and Cue ..................................................................... 10
Extended cue functions ......................................................................................... 10
Meters ..................................................................................... 10
Added functions for meter display ......................................................................... 10
Graphic EQ, Effects, and Premium Rack ................................. 11
Improvements in popup window operation........................................................... 11
Improved display for tap tempo function............................................................... 11
I/O device and external head amp ......................................... 12
Added display functions for device status............................................................... 12
Improvements in I/O device settings...................................................................... 14
User settings............................................................................ 15
Added functions for the GAIN/PAN/ASSIGN knobs (assignable encoders)............... 15
Added custom fader bank functions ....................................................................... 15
Added load/save functions ..................................................................................... 18
Added function for recovering from USB overcurrent.............................................. 21
Other functions ....................................................................... 22
Improvements to the channel name display ........................................................... 22
Added channel color .............................................................................................. 22
Added GPI functions............................................................................................... 23
Initializing the Dante audio network settings .......................................................... 23
Block Diagram........................................................................................................ 24
SELECTED CHANNEL section
V1.7 Supplementary Manual
3
SELECTED CHANNEL section
Improved gain indication
In the GAIN/PATCH field of the SELECTED CHANNEL VIEW screen, the analog gain and digital
gain of the head amp are both shown at all times.
A.GAIN indication
•Gain value
If analog gain is assigned to the GAIN knob, the digital gain value is shown here.
The GAIN knob, +48V indicator, and HPF ON indicator are not
shown if an input without a head amp is patched to the input
channel.
D.GAIN indication
Gain value
If digital gain is assigned to the GAIN knob, the analog gain value is shown here.
The analog gain value is not shown if an input without a head amp
is patched to the input channel.
GAIN knob
OVER indicator
Ø (Phase) indicator
+48V indicator
HPF ON indicator
Gain value
Centralogic section
V1.7 Supplementary Manual
4
Improved HPF indication
The HPF status of an external head amp such as the R-series is now shown in the GAIN/PATCH field
of the SELECTED CHANNEL VIEW screen.
HPF ON indicator
Indicates the HPF on/off status of the external head amp.
The HPF/EQ popup screen now shows an HPF ON indicator and the cutoff frequency.
1 HA HPF ON indicator
Indicates the HPF on/off status of the external head amp.
2 FREQUENCY
Indicates the HPF cutoff frequency of the external head amp.
Centralogic section
Improved DCA group indication
If 15 or more channels are registered in the DCA member indication of the OVERVIEW screen, you
can now use the multifunction knobs of the Centralogic section to scroll the channels.
1
2
Input channels
V1.7 Supplementary Manual
5
Input channels
Additional head amp setting functions when
changing the input patching
When you change the input patching, you can now choose whether the HA (Head Amp) settings of the
port you patched will be used, or whether the HA settings of the channel will be copied to the port you
patched.
Make this selection in the PORT SELECT popup window and the PATCH/NAME popup window.
NOTE
You can also choose whether the HA settings from CL Editor will be used without change or
copied from the channel. For details, refer to the CL Editor Owners Manual.
Settings in the PORT SELECT popup window
1. In the OVERVIEW screen, press the GAIN/PATCH field to access the GAIN/PATCH
popup window.
2. Press the PATCH button (or INPUT PORT button) to access the PORT SELECT popup
window.
3. Press a button in the HA INFO field to specify whether the HA settings of the port
or the HA settings of the channel will take priority.
1 TAKE FROM PORT button
The HA settings of the port will take priority. Even if you change the patching, the HA settings of
the port will remain unchanged.
2 TAKE FROM CHANNEL button
The HA settings of the channel will take priority. The HA settings of the port that had been
previously patched will be copied to the newly-patched port.
A confirmation dialog box will appear when you switch buttons.
If an input without a HA is patched to the input channel, the dialog box is not shown.
1 2
Input channels
V1.7 Supplementary Manual
6
If the channels HA settings are selected, the following HA settings will be copied from the channel
to the port that is patched. If you patch the input channel from an input that does not have these
settings (i.e., that does not have a HA), the default values will be specified.
NOTE
If youre newly patching a previously-unpatched input channel, the default values will be specified
if the HA INFO field’s TAKE FROM CHANNEL button is pressed.
Settings in the PATCH/NAME popup window
1. In the OVERVIEW screen, press a channel number / channel name field to access
the GAIN/PATCH popup window.
2. Make settings in the same way as in the PORT SELECT popup window.
HA setting Default value
HA gain amount –6 dB
HPF on/off Off
Phantom power on/off Off
Gain compensation on/off Off
Grouping and linking
V1.7 Supplementary Manual
7
Grouping and linking
Improved display of DCA group / MUTE group
names
In the DCA/MUTE GROUP ASSIGN MODE popup window, the DCA group names and mute group
names can now be displayed.
Editing and displaying DCA group names
1. In the Function Access Area, press the CH JOB button.
2. Press the DCA GROUP button to access the DCA/MUTE GROUP ASSIGN MODE
popup window.
1 NAME EDIT button
Edits the group name of the currently selected DCA group.
3. Press the NAME EDIT button to access the NAME screen.
The keyboard window will appear, allowing you to enter or edit the text.
4. The DCA group name is shown on the DCA group select button.
1
Grouping and linking
V1.7 Supplementary Manual
8
Editing and displaying mute group names
Mute group names can be specified in the same way as for DCA groups.
1 NAME EDIT button
Edits the group name of the currently selected MUTE group.
The registered group name is shown in the RECALL SAFE MODE popup window, the GLOBAL
RECALL SAFE popup window, and the GLOBAL PASTE window’s PATCH/NAME tab.
Added functions for DCA groups
Sends from an input channel to a bus whose send point is set to PRE can now be assigned to be muted
by a DCA group.
1 POST ONLY button
Specifies the object of muting as POST only.
2 PRE & POST button
Specifies the object of muting as PRE and POST.
The PRE&POST indicator is shown below a DCA group that has this setting.
The object of muting for a DCA group can be specified individually for each DCP group.
For channels that are assigned to more than one DCA group, muting any of the DCA groups will mute
that channels signal path (including sends to the corresponding buses).
1
1 2
Grouping and linking
V1.7 Supplementary Manual
9
Improvements in channel link display
A link indicator has been added to the CH LINK MODE popup window, making it easier to determine
the currently-assigned link group.
Accessing the CH LINK MODE popup window
1. In the Function Access Area, press the CH JOB button.
2. Press the CH LINK button to open the CH LINK MODE popup window.
3. Use the [SEL] keys or the channel display field to select the channels that you want
to link; the link indicator will show the link group.
If a channel belonging to a link group is selected, the associated link group is shown. The LINK
PARAMETER field and SEND PARAMETER field show the link settings.
While you hold down the [SEL] key of a channel that does not belong to any link group, the link
indicator shows the link group that will be created next. The LINK PARAMETER field and SEND
PARAMETER field show the settings of the link group that had been previously displayed.
Channel display fieldLink indicator
Monitor and Cue
V1.7 Supplementary Manual
10
Monitor and Cue
Extended cue functions
The cue monitor level range has been expanded to –30 dB – +20 dB.
Make this setting in the CUE popup window.
Accessing the CUE popup window
1. In the Function Access Area, press the MONITOR button to access the MONITOR
screen.
2. Press the CUE popup display button.
Use the knob to adjust the monitor level in the range of –30 dB – +20 dB.
Meters
Added functions for meter display
PRE GC METER and POST DIGITAL GAIN METER have been added to the METERING POINT
field of the METER screen. In addition, the name of PRE HPF has been changed to PRE D.GAIN.
Select the meter point at which the level will be detected.
For INPUT METER
PRE GC .......................................Immediately before GAIN COMPENSATION
POST D.GAIN...........................Immediately after DIGITAL GAIN
Graphic EQ, Effects, and Premium Rack
V1.7 Supplementary Manual
11
Graphic EQ, Effects, and Premium Rack
Improvements in popup window operation
In the EFFECT popup window, GEQ popup window, and PREMIUM RACK popup window, you can
now use the [SEL] keys to switch channels.
In the EFFECT popup window, pressing a top panel [SEL] key while editing an effect parameter will
switch the screen to the effect that is inserted in that channel. The same will occur in the GEQ popup
window and the PREMIUM RACK popup window. You can also switch from the EFFECT popup
window to the GEQ popup window or the PREMIUM RACK popup window.
The following items will change in conjunction with the channel being operated.
Selected channel indication in the Function Access Area
Channel being operated in the synchronized CL Editor
If no insert settings have been made in the channel to which you switched, a dialog box informing you
of this will appear.
Improved display for tap tempo function
If TAP TEMPO is assigned to a user defined key, and you are specifying the BPM (tempo value) by
pressing that key, a popup window like the following will now appear.
Tap tempo popup window
NOTE
This popup window will not appear if the EFFECT EDIT popup window in which you’re specifying
tap tempo is open.
ATT
Keyin
Self PRE EQ
Self POST EQ
MIX21-24 OUT
CH[1-8,9-16,17-24,25-32,33-40,41-48, 49-56, 57-64, 65-72]POST EQ(CL5)
CH[1-8,9-16,17-24,25-32,33-40,41-48, 49-56, 57-64]POST EQ(CL3)
CH[1-8,9-16,17-24,25-32,33-40,41-48]POST EQ(CL1)
ON
4BAND
EQ
GATE
DUCK
EXPAND
COMP
GR METER
COMP
COMPAND
DE-ESSER
KEYIN CUE
HPF
PRE HPF
POST EQ
INSERT
METER
LEVEL/
DCA1-16
PRE FADER
PRE FADER POST ON
PRE FADER
INSERT OUT
PRE EQ
INSERT OUT
To OUTPUT PATCH
PRE EQ
INSERT POINT
POST ON INSERT OUT
PRE FADER INSERT OUT
PRE EQ INSERT OUT
GR METER
METER
POST ON
METER
DYNA2OUT
METER
DYNA1OUT
METER
EQ OUT
METER
PRE EQ
PRE HPF / PRE EQ / PRE FADER/POST ON
ON LEVEL
DIRECT OUT 1-72{64,48}
To OUTPUT PATCH
PAN LINK
MATRIX1,3...7
MATRIX2,4...8
CUE R
MIX1,3...23
MIX2,4...24
CUE L
Keyin Filter
CH INSERT IN
1-72{64,48}
To RACKIN PATCH
INSERT
CH 1-72{64,48}
(PRE FADER)PFL / (POST ON)AFL / POST PAN L
ON
ON
ST L
MONO(C)
ST R
MIX
12 2324
ST
LR
M
O
N
O
(C)
MATRIX
12 78
CUE
LR
METER
PRE D.GAIN
CH INSERT OUT
1-72{64,48}
PRE EQ / PRE FADER / POST ON
ON
LEVEL
ON
LEVEL
LEVEL
PAN
ON
PRE EQ / PRE FADER / POST ON
To MATRIX
VARI
To MATRIX
VARI
STEREO
PRE EQ / PRE FADER / POST ON
ON
LEVEL
ON
LEVEL
LEVEL
PAN
ON
PRE EQ / PRE FADER / POST ON
To MIX
VARI
To MIX
VARI
STEREO
To MIX
FIXED
POST ON
ON
ON
To MIX
FIXED
STEREO
POST PAN L
POST PAN R
ON
ON
PAN
TO ST
LR MONO
TO MONO
LCR
TO LCR
CSR
POST PAN L
POST PAN R
(PRE FADER)PFL / (POST ON)AFL / POST PAN R
PAN MODE
DELAY
Max
1000ms
INSERT
POST ON
INSERT OUT
Digital
GAIN
OSCILLATOR
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
METER
POST DG
72
{64,
48}
INPUT PATCH
I/O device and external head amp
V1.7 Supplementary Manual
12
I/O device and external head amp
Added display functions for device status
You can now use the touch screen to verify the status of a connected CL series or R-series unit (except
the Ro8-D) or the Dante status.
In order to verify the status of an R-series unit from the console, it must be assigned to REMOTE HA
in DANTE SETUP.
CL series
The SETUP field of the DANTE SETUP screen shows indicators for the status of the CL series console
and the Dante network.
R-series
The Rio field of the I/O DEVICE screen shows indicators for the status of the R-series units and the
Dante network.
For firmware that predates support for V1.61, the version indication will be yellow and the indicator
will be unlit.
I/O device and external head amp
V1.7 Supplementary Manual
13
Messages
Error, warning, and information messages are displayed. Messages are also displayed in the Dante
Controller Error Status field.
Each indicator lights or flashes as described below:
Error Messages
The SYSTEM indicators will remain lit/blinking as follows until the problem has been resolved.
If service is necessary, please contact the Yamaha service center listed in the CL5/CL3/CL1 owners
manual.
Warning Messages
The indicators will light and/or flash as shown until the cause is resolved.
If the green [SYNC] indicator is unlit, the units clock is unconfirmed.
No call-out The indicator is off.
Light The indicator remains lit steadily.
Flash The indicator continues to flash.
Flash x2 The indicator flashes twice cyclically.
Flash x3 The indicator flashes three times cyclically.
SYSTEM Indicators Description Possible Solution
An internal error has occurred.
The device has failed. Contact your
Yamaha dealer for repair.
The MAC address setting has
been corrupted and no
communication can occur via
Dante.
The internal memory has
been corrupted.
Use the front-panel DIP switches to
set START UP MODE to REFRESH,
then restart the unit. If the problem
persists after setting START UP
MODE back to RESUME, consult your
Yamaha dealer.
UNIT ID is not unique.
Set a unique UNIT ID number for the
Dante network.
Flash x3Light
The DIP switches are not set
correctly.
Check the DIP switch settings, and set
them correctly.
Dante flow number limit was
exceeded.
Examine the Dante network routing.
SYNC Indicators Description Possible Solution
The word clock is not set
correctly.
Set the clock master and sampling
frequency correctly on the CL5/CL3/
CL1-native device or in Dante
Controller.
Dante Network circuit is
broken.
Make sure that the Ethernet cables
are not removed or short-circuited.
Other Dante-compatible
devices cannot be found due
to an incorrectly-wired Dante
Network.
Make sure that the Ethernet cables
are connected correctly.
SYSTEM Indicators Description Possible Solution
Flash
FlashLight
Flash
Flash x2
Flash x3
I/O device and external head amp
V1.7 Supplementary Manual
14
If the green indicator is flashing, the unit is the clock master.
If the green indicator is lit, the unit is the clock slave and the clock is synchronized.
Information Messages
The status is shown by the lit/flashing state of the indicator.
If the orange [SYNC] indicator is unlit, the unit is operating normally.
If the green [SYNC] indicator is unlit, the units clock is unconfirmed.
Improvements in I/O device settings
When mounting an I/O device on the Dante audio network, the settings and indications have been
improved so that the units can be differentiated by their device type.
The following device labels are detected as supported devices.
Y###-**********
# is a three-digit hexadecimal number (000–FFF) consisting of the digits 0–9 and the uppercase
characters A–F
* indicates any desired character (alphabetical uppercase or lowercase, numerals, or - (hyphen)
may be used)
Up to 31 characters including the ‘Y’ are supported.
The DEVICE LIST field of the DEVICE SELECT popup window shows the device label and device type.
SYNC Indicators Description Possible Solution
A non-GbE-compatible device
is connected.
When transferring audio via Dante,
use device that supports GbE.
The SECONDARY connector
has taken over
communications during
redundant network operation.
Check the circuit connected to the
PRIMARY connector.
An abnormality has occurred
on the circuit connected to the
SECONDARY connector
during redundant network
operation.
Check the circuit connected to the
SECONDARY connector.
SYNC Indicators Description Explanation
Synchronization is occurring.
Please wait until the unit synchronizes
completely. It may take up to
45 seconds to synchronize completely.
(If the DIP switches of an R-series unit
are set to REFRESH, synchronization
will not be completed until the CL
series unit that is set to “with RECALL
has started up.)
The unit is functioning
correctly as the word clock
master.
The unit is operating as the word clock
master.
The unit is functioning
correctly as the word clock
slave.
The unit is operating as the clock slave
and the clock is synchronized.
Light
Light
or
flash
Flash
Light
or
flash
Flash x2
Light
or
flash
User settings
V1.7 Supplementary Manual
15
User settings
Added functions for the GAIN/PAN/ASSIGN knobs
(assignable encoders)
Functions have been added to the assignable encoders in SENDS ON FADER mode.
If ASSIGN is selected by the top panel [GAIN/PAN/ASSIGN] key
Use the assignable encoders to adjust the channel levels.
Channel name display indication
If PAN is selected by the top panel [GAIN/PAN/ASSIGN] key
Use the assignable encoders to adjust the pan of the send from the channel to the MIX/MATRIX bus
(buses that are assigned to stereo send in the BUS SETUP screen).
Channel name display indication
Added custom fader bank functions
Custom fader bank settings can now be stored/recalled for individual scenes.
Custom fader bank settings are separated into areas for each model and stored together in the scene
data.
NOTE
Custom fader bank settings differ between models, and are not compatible. For example, custom
fader bank settings included in a scene stored by the CL5 will not be reproduced if that scene is
recalled on the CL3 or CL1. The settings must be created and stored on the CL3 or CL1.
Channel level
Adjust using the assignable encoders.
Send level to MIX/MATRIX bus
Adjust using the top panel faders.
Pan of the send from the channel to the MIX/MATRIX bus
Adjust using the assignable encoders.
Send level to MIX/MATRIX bus
Adjust using the top panel faders.
CL5
CL5 console
Recall Store Recall Store Recall Store
CL3 CL1
CL3 console CL1 console
Custom fader bank settings
User settings
V1.7 Supplementary Manual
16
Focus function
For the focus function, you can specify for each scene whether custom bank settings will be recalled
(loaded).
1. Press the SCENE field of the Function Access Area.
2. Press the FOCUS tab at the bottom of the SCENE LIST window.
Custom bank settings are included in OTHER PARAMs.
3. Press the SET button of the scene for which you want to make settings; the FOCUS
RECALL popup window will appear.
4. Press a button in the FOCUS PARAMETER field to access the FOCUS PARAMETER
popup window.
5. Verify the object of focus.
6. Press the CLOSE button to close the popup window; then perform a recall
operation.
User settings
V1.7 Supplementary Manual
17
Recall Safe function
In the Recall Safe function, you can specify that custom bank settings of all scenes will be globally
excluded from recall operations.
1. In the Function Access Area, press the CH JOB button to access the CH JOB popup
window.
2. Press the RECALL SAFE button to access the RECALL SAFE MODE popup window.
3. Press the GLOBAL RECALL SAFE field to access the GLOBAL RECALL SAFE popup
window.
4. Press the CUSTOM FADER BANK button to specify it as the object of recall safe.
5. Press the CLOSE button to close the popup window; then perform a recall
operation.
Global Paste function
The global paste function lets you copy and paste the custom bank settings of the current scene to scene
data in memory.
1. In the Function Access Area, press the SCENE field to access the SCENE LIST
window.
2. Press the GLOBAL PASTE button located in the upper part of the SCENE LIST
window to open the GLOBAL PASTE window.
3. Select the PATCH/OTHERs tab.
4. Select the CUSTOM FADER BANK button.
5. In the DESTINATION SCENE area, select the range of paste-destination scenes.
6. Press the PASTE button.
NOTE
If the internal data of the CL console was loaded from a USB flash drive as a package, load the
user authentication key as necessary. The custom fader bank settings of the user who loaded the
data will be applied.
When in PREVIEW mode, changes from CL Editor are not reflected immediately. They will be
applied when you exit PREVIEW mode.
User settings
V1.7 Supplementary Manual
18
Added load/save functions
CL series settings can now be loaded individually from a USB flash drive, or saved individually to a USB
flash drive.
Loading settings from a USB flash drive
Follow the steps below to load CL settings from the USB flash drive into the CL series console.
1. In the Function Access Area, press the SETUP button to access the SETUP screen.
2. Press the SAVE/LOAD button to access the SAVE/LOAD popup window.
3. To select the file that you want to load, press the name of the desired file in the file
list, or rotate the corresponding multifunction knob on the panel.
4. Press the LOAD button to access the LOAD SELECT popup window.
1 TYPE field
Selects the type of data to be loaded.
2 SOURCE field
This area lists the data that is saved on the USB flash drive.
3 DESTINATION field
Indicates the load-destination.
4 Data selection knob
This knob selects the data shown in the field.
5 MULTI SELECT button
By pressing this button you can make a selection containing multiple items of data.
6 SELECT ALL button
Press this button to select all items.
7 CLEAR ALL button
Press this button to clear all selections.
5. Press the tabs and buttons of the TYPE field to select the type of data that you want
to load.
The content shown in the TYPE field will vary depending on the tab you select.
•ALL tab
All items will be the target of the operation.
•SCENE tab
Scene memories will be the target of the operation.
INPUT/OUTPUT tab
The following table lists the items that you can select.
EFFECT/GEQ tab
The following table lists the items that you can select.
PREMIUM tab
The following table lists the items that you can select.
1
23
4 45 67
Buttons Data content
IN CH LIB Input channel library
OUT CH LIB Output channel library
IN EQ LIB Input EQ library
OUT EQ LIB Output EQ library
DYNA LIB Dynamics library
Buttons Data content
EFFECT LIB Effect library
GEQ LIB GEQ library
Buttons Data content
5033 LIB Portico 5033 library
5043 LIB Portico 5043 library
U76 LIB U76 library
User settings
V1.7 Supplementary Manual
19
SETUP tab
The following table lists the items that you can select.
NOTE
If you load output port items individually, the settings of the channel assigned to the port will not
be reflected. Recall them after loading a scene that includes input/output patching with those
channel settings.
ADMIN tab
The following table lists the items that you can select.
6. In the SOURCE field, add a check mark ( ) to select the data that you want to
load.
If you want to load multiple items of data in a single operation, press the MULTI SELECT button.
7. In the DESTINATION field, add a check mark ( ) to the load-destination.
8. Press the LOAD button.
NOTE
If the number of loadable data items in the DESTINATION list is less than the number of items
being loaded, the allowable number of data items will be loaded.
Saving the CL console’s settings on a USB flash drive
Heres how to save the CL consoles internal data on a USB flash drive.
1. In the Function Access Area, press the SETUP button to access the SETUP screen.
2. Press the SAVE/LOAD button to access the SAVE/LOAD popup window.
3. If necessary, press the directory icon and change the directory.
4. Press the SAVE button to access the SAVE SELECT popup window.
1 TYPE field
This specifies the types of data to be saved.
2 SOURCE field
This shows the internal data of the CL series console.
3 DESTINATION field
Indicates the save-destination.
4 Data selection knob
This knob selects the data shown in the field.
5 MULTI SELECT button
By pressing this button you can make a selection containing multiple items of data.
Opt-2A LIB Opt-2A library
EQ-1A LIB EQ-1A library
DynaEQ LIB DynamicEQ library
Buttons Data content
MIXER SETUP Mixer setup
OUTPUT PORT Output ports
MONITOR CUE/MONITOR/OSCILLATOR/TALKBACK
MIDI SETUP MIDI Setup
MIDI PGM MIDI program changes
MIDI CTL MIDI control changes
Dante In Patch DANTE input patch library
Buttons Data content
ADMIN PREF PREFERENCE (For administrator)
ADMIN UDEF USER DEFINED KEYS/USER DEFINED KNOBS (For administrator)
ADMIN FADER CUSTOM FADER BANK (For administrator)
GUEST PREF PREFERENCE (For guest)
GUEST UDEF USER DEFINED KEYS/USER DEFINED KNOBS (For guest)
GUEST FADER CUSTOM FADER BANK (For guest)
GUEST LEVEL USER LEVEL (For guest)
Buttons Data content
3
4 45 6 7
1
2
User settings
V1.7 Supplementary Manual
20
6 SELECT ALL button
Press this button to select all items.
7 CLEAR ALL button
Press this button to clear all selections.
5. Press the tabs and buttons of the TYPE field to select the type of data that you want
to save.
The content shown in the TYPE field will vary depending on the tab you select.
ALL tab
All items will be the target of the operation.
•SCENE tab
Scene memories will be the target of the operation.
INPUT/OUTPUT tab
The following table lists the items that you can select.
EFFECT/GEQ tab
The following table lists the items that you can select.
PREMIUM tab
The following table lists the items that you can select.
SETUP tab
The following table lists the items that you can select.
NOTE
If you save output port items individually, the settings for the channel assigned to the port will not
be saved. You will also need to save the scene that includes the input/output patching for those
channel settings.
Items that are included in the ADMIN tab when loading items individually will be included in ALL
when saving.
6. In the SOURCE field, add a check mark ( ) to select the data that you want to
save.
If you want to save multiple items of data in a single operation, press the MULTI SELECT button.
7. In the DESTINATION field, add a check mark ( ) to the save-destination.
8. Press the SAVE button to access the FILE SAVE popup window.
9. Enter a file name or comment, and press the SAVE button.
Buttons Data content
IN CH LIB Input channel library
OUT CH LIB Output channel library
IN EQ LIB Input EQ library
OUT EQ LIB Output EQ library
DYNA LIB Dynamics library
Buttons Data content
EFFECT LIB Effect library
GEQ LIB GEQ library
Buttons Data content
5033 LIB Portico 5033 library
5043 LIB Portico 5043 library
U76 LIB U76 library
Opt-2A LIB Opt-2A library
EQ-1A LIB EQ-1A library
DynaEQ LIB DynamicEQ library
Buttons Data content
MIXER SETUP Mixer setup
OUTPUT PORT Output ports
MONITOR CUE/MONITOR/OSCILLATOR/TALKBACK
MIDI SETUP MIDI Setup
MIDI PGM MIDI program changes
MIDI CTL MIDI control changes
Dante In Patch DANTE input patch library
User settings
V1.7 Supplementary Manual
21
Added function for recovering from USB
overcurrent
Even if the connection with the USB device was stopped because an overcurrent condition occurred at
the USB port, it is now possible to reconnect the USB device without restarting.
Recovery procedure
After removing the cause of the overcurrent at the USB port, press the location that shows “USB
REMOUNT” at the FORMAT button of the SAVE/LOAD screen.
Other functions
V1.7 Supplementary Manual
22
Other functions
Improvements to the channel name display
Improvements have been made to the channel name display and channel color indicator.
The channel on/off status is now shown in SENDS ON FADER mode.
If NAME DISPLAY is set to “NAME ONLY” in the PREFERENCE page of the USER SETUP popup
window, the channel number is now shown.
Added channel color
Black can now be specified as a channel color. If black is selected for a channel, its channel color
indicator will be unlit.
Make this setting in the CH COLOR/ICON popup window.
Channel color setting
1. Access the OVERVIEW screen that includes the input channel whose channel color
you want to specify.
2. Press the channel number/channel name field of that channel to access the
PATCH/NAME popup window.
3. Select a channel color.
Channel on
Channel off
Channel number indication
Other functions
V1.7 Supplementary Manual
23
Added GPI functions
You can now select the attributes (latched or unlatched) of an external switch connected to a GPI IN
port.
GPI settings
1. In the Function Access Area, press the SETUP button to access the SETUP screen.
2. Press the MIDI/GPI button to access the MIDI/GPI screen.
3. Press the GPI tab.
Each time you press a switch attribute button, its indication will alternate between LATCH and
UNLATCH.
LATCH (a switch that alternately turns on/off each time it is pressed) is selected.
UNLATCH (a switch that is on only while pressed and is off when released) is selected.
Initializing the Dante audio network settings
It is now possible for Dante-related settings to also be initialized to their factory-set state when an error
occurs on the Dante audio network.
NOTICE
When you initialize, all console settings including the Dante audio network settings that had been
previously saved in memory will be lost.
Proceed with the following operation only if you are very sure you want to do this!
1. While holding down the SCENE MEMORY [STORE] key and [INC] key on the panel,
turn on the power to the CL console.
2. A message indicates that initialization is complete; press the CLOSE button.
Switch attribute button
V1.7 Supplementary Manual
24
INSERT IN
PATCH
(OUTPUT CH)
2
POST ON
INSERT OUT
PREMIUM
RACK IN
PATCH
EFFECT
RACK IN
PATCH
64
CASCADE
IN
SELECT
SLOT1 1-16
SLOT2 1-16
SLOT3 1-16
ATT
Keyin
Self PRE EQ
Self POST EQ
MIX21-24 OUT
CH[1-8,9-16,17-24,25-32,33-40,41-48, 49-56, 57-64, 65-72]POST EQ(CL5)
CH[1-8,9-16,17-24,25-32,33-40,41-48, 49-56, 57-64]POST EQ(CL3)
CH[1-8,9-16,17-24,25-32,33-40,41-48]POST EQ(CL1)
ON
4BAND
EQ
GATE
DUCK
EXPAND
COMP
GR METER
COMP
COMPAND
DE-ESSER
KEYIN CUE
HPF
PRE HPF
POST EQ
INSERT
METER
LEVEL/
DCA1-16
PRE FADER
PRE FADER POST ON
PRE FADER
INSERT OUT
PRE EQ
INSERT OUT
To OUTPUT PATCH
PRE EQ
INSERT POINT
POST ON INSERT OUT
PRE FADER INSERT OUT
PRE EQ INSERT OUT
GR METER
METER
POST ON
METER
DYNA2OUT
METER
DYNA1OUT
METER
EQ OUT
METER
PRE EQ
PRE HPF / PRE EQ / PRE FADER/POST ON
ON LEVEL
DIRECT OUT 1-72{64,48}
To OUTPUT PATCH
PAN LINK
MATRIX1,3...7
MATRIX2,4...8
CUE R
TB INPUT
METER
HA
MIX1,3...23
MIX2,4...24
CUE L
Keyin Filter
CH INSERT IN
1-72{64,48}
To RACKIN PATCH
To OUTPUT PATCH
To RACKIN PATCH
(21-24)To KEYIN
To MONITOR SELECT
ATT
4BAND
EQ
COMP
COMPAND
EXPAND
INSERT
POST EQ
LEVEL
PRE EQ
INSERT OUT
PRE EQ
GR METER
METER
DYNA OUT
METER
EQ OUT
METER
PRE EQ
Keyin
Self PRE EQ/Self POST EQ/MIX21-24 OUT/
MIX(1-8,9-16,17-24) POST EQ
PRE FADER
CUE ON
(PRE FADER)PFL / (POST ON)AFL
INSERT
MIX 1-24
CH 1-72{64,48}
72
{64,
48}
MATRIX 1-8
CASCADE OUT
CASCADE IN
To MONITOR
SELECT
TALKBACK
INPUT
SELECT
ON
DANTE IN 1-64
OMNI IN 1-8
(PRE FADER)PFL / (POST ON)AFL / POST PAN L
ON
ON
ST L
MONO(C)
ST R
MIX
12 2324
ST
LR
M
O
N
O
(C)
MATRIX
12 78
CUE
LR
To OUTPUT PATCH
To OUTPUT PATCH
To OUTPUT PATCH
To OUTPUT PATCH
To OUTPUT PATCH
To OUTPUT PATCH
To OUTPUT PATCH
To OUTPUT PATCH
To OUTPUT PATCH
CUE CASCADE OUT LR
STEREO CASCADE OUT L,R,MONO(C)
MIX CASCADE OUT1-24
MATRIX CASCADE OUT1-8
To OUTPUT PATCH
To OUTPUT PATCH
To OUTPUT PATCH
To OUTPUT PATCH
METER
PRE D.GAIN
+48V
+48V MASTER
+48V
AD
[TALKBACK
INPUT]
TALKBACK
INPUT
TALKBACK
LEVEL
ON
1
2
3
+
-
+48V
AD
[OMNI IN]
[1-8]
OMNI IN
+
-
1
2
3
METER
HA
CH INSERT OUT
1-72{64,48}
PRE EQ / PRE FADER / POST ON
ON
LEVEL
ON
LEVEL
LEVEL
PAN
ON
PRE EQ / PRE FADER / POST ON
To MATRIX
VARI
To MATRIX
VARI
STEREO
PRE EQ / PRE FADER / POST ON
ON
LEVEL
ON
LEVEL
LEVEL
PAN
ON
PRE EQ / PRE FADER / POST ON
To MIX
VARI
To MIX
VARI
STEREO
To MIX
FIXED
POST ON
ON
ON
To MIX
FIXED
STEREO
POST PAN L
POST PAN R
ON
ON
MIX INSERT IN 1-24
STEREO INSERT IN L,R,MONO(C)
24
3
CH INSERT IN 1-72{64,48}
MATRIX INSERT IN 1-8
8
LEVEL
ON
Pink Noise
Burst Noise
HPF LPF
METER
OSC
OSCILLATOR
Sine Wave
Refer to CL5/CL3/CL1 Mixer Block Diagram 2/2
INPUT
PATCH
DANTE IN
1-64
OMNI IN
1-8
SLOT3 1-16
SLOT2 1-16
SLOT1 1-16
STEREO OUT
L,R,MONO(C)
CH
INSERT OUT
1-72{64,48}
MIX
INSERT OUT
1-24
STEREO
INSERT OUT
L,R,MONO(C)
MATRIX
INSERT OUT
1-8
GEQ
RACK IN
PATCH
GEQ1 IN
A(L)/B(R)
GEQ2-16 IN
A(L)/B(R)
FX1 IN
A(L)/B(R)
FX2-8 IN
A(L)/B(R)
INSERT IN
PATCH
(INPUT CH)
FX1 OUT
A(L)/B(R)
FX2-8 OUT
A(L)/B(R)
PR1-8 OUT
A(L)/B(R)
FX1-8 OUT
A(L)/B(R)
GEQ RACK1(GEQ1)
Flex15GEQ
METER
RACK IN A
METER
RACK IN B
METER
RACK OUT A
METER
RACK OUT B
GEQ RACK2-16(GEQ2-16) (same as GEQ RACK1)
EFFECT RACK2-8(FX2-8) (same as EFFECT RACK1)
EFFECT RACK1(FX1)
EFFECT
METER
RACK IN L
METER
RACK IN R
METER
RACK OUT L
METER
RACK OUT R
Flex15GEQ
METER
RACK IN A
METER
RACK IN B
METER
RACK OUT A
METER
RACK OUT B
EFFECT CUE
PAN
TO ST
LR MONO
TO MONO
LCR
TO LCR
CSR
POST PAN L
POST PAN R
(PRE FADER)PFL / (POST ON)AFL / POST PAN R
EFFECT CUE
SELECT
PR1-8 OUT L/R
EFFECT CUE
ON
KEYIN CH1-72{64,48}
KEYIN CUE
KEYIN CUE
SELECT
ON
ON
POST ON
METER
POST ON
MIX OUT1-24
INSERT
METER
PRE FADER
PRE FADER
INSERT OUT
To OUTPUT PATCH
MIX
INSERT IN 1-24
To RACKIN PATCH
MIX
INSERT OUT 1-24
ST L
MONO(C)
ST R
ONLEVEL
ON
LEVEL
LEVEL
PAN/BAL
ON
To MATRIX
VARI
To MATRIX
VARI
STEREO
MATRIX1,3...7
MATRIX2,4...8
CUE ON
(PRE FADER)PFL / (POST ON)AFL
To OUTPUT PATCH
To MONITOR SELECT
ATT
4BAND
EQ
COMP
COMPAND
EXPAND
INSERT
POST EQ
LEVEL
PRE EQ
INSERT OUT
PRE EQ
GR METER
METER
DYNA OUT
METER
EQ OUT
METER
PRE EQ
Keyin
Self PRE EQ/Self POST EQ/MIX21-24 OUT/
ST(L,R,MONO(C)) POST EQ
PRE FADER
STEREO L,R,MONO(C)
ON
POST ON
METER
POST ON
STEREO OUT
L,R,MONO(C)
INSERT
METER
PRE FADER
BAL
PRE FADER
INSERT OUT
To OUTPUT PATCH
STEREO
INSERT IN L,R,MONO(C)
To RACKIN PATCH
STEREO
INSERT OUT L,R,MONO(C)
To OUTPUT PATCH
To MONITOR SELECT
ATT
4BAND
EQ
COMP
COMPAND
EXPAND
INSERT
POST EQ
LEVEL
PRE EQ
INSERT OUT
PRE EQ
GR METER
METER
DYNA OUT
METER
EQ OUT
METER
PRE EQ
Keyin
Self PRE EQ/Self POST EQ/MIX21-24 OUT/
MATRIX1-8 POST EQ
PRE FADER
ON
POST ON
METER
POST ON
MATRIX OUT 1-8
INSERT
METER
PRE FADER
PRE FADER
INSERT OUT
To OUTPUT PATCH
MATRIX
INSERT IN 1-8
To RACKIN PATCH
MATRIX
INSERT OUT 1-8
CUE ON
(PRE FADER)PFL / (POST ON)AFL
PAN MODE
GAIN/TRIM
PAN/BAL
TO ST
LR MONO
TO MONO
LCR
TO LCR
CSR
POST ON
PAN MODE
PRE FADER / POST ON
PRE FADER / POST ON
PRE FADER / POST ON
31BandGEQ
METER
RACK IN
METER
RACK OUT
31BandGEQ
METER
RACK IN
METER
RACK OUT
SLOT1 1-16
SLOT2 1-16
SLOT3 1-16
To MATRIX INSERT IN
To STEREO INSERT IN
To MIX INSERT IN
To CH INSERT IN
PRE FADER / POST ON
ON
LEVEL
ON
LEVEL
LEVEL
PAN/BAL
ON
To MATRIX
VARI
To MATRIX
VARI
STEREO
MATRIX1,3...7
MATRIX2,4...8
PR1-2 OUT
A(L)/B(R)
FX1-8 OUT
A(L)/B(R)
To CASCADE IN
SELECT
[SLOT]
SLOT1
SLOT2
SLOT3
METER
SLOTIN
16
16
16
METER
SLOTIN
METER
SLOTIN
72
MATRIX OUT
1-8
MIX OUT
1-24
OUTPUTS
[DANTE]
DANTE
INPUT
METER
DANTE
IN
DELAY
Max
1000ms
INSERT
POST ON
INSERT OUT
PR1 IN
A(L)/B(R)
PR2-8 IN
A(L)/B(R)
PR1 OUT
A(L)/B(R)
PR2-8 OUT
A(L)/B(R)
PREMIUM RACK2-8 (same as PREMIUM RACK1)
PREMIUM RACK1(PR1)
PROCESSOR
METER
RACK IN L
METER
RACK IN R
METER
RACK OUT L
METER
RACK OUT R
EFFECT CUE
FX1-8 OUT L/R
INSERT
INSERT POINT
POST ON INSERT OUT
PRE FADER INSERT OUT
PRE EQ INSERT OUT
INSERT POINT
POST ON INSERT OUT
PRE FADER INSERT OUT
PRE EQ INSERT OUT
POST ON
INSERT OUT
INSERT
POST ON
INSERT OUT
INSERT
INSERT POINT
POST ON INSERT OUT
PRE FADER INSERT OUT
PRE EQ INSERT OUT
RECORDER CUE
SELECT
PLAYBACK OUT L/R
RECORDER CUE
ON
RECORDER INL/R
To MONITOR SELECT
METER
PLAYBACK OUT
RECORDER CUE
[PLAYBACK
OUT]
GAIN
DECODER
Refer to CL5/CL3/CL1 Mixer Block Diagram 2/2
CUE / MONITOR
16
ON
METER
LEVEL/
DCA1-16
PRE FADER
PRE FADER
POST ON
METER
POST ON
PAN LINK
MATRIX1,3...7
MATRIX2,4...8
CUE R
MIX1,3...23
MIX2,4...24
CUE L
(PRE FADER)PFL / (POST ON)AFL / POST PAN L
ON
ON
ST L
MONO(C)
ST R
To MATRIX
To MIX
SAME as INPUT1-72{64,48}
PAN/BAL
TO ST
LR MONO
TO MONO
LCR
TO LCR
CSR
POST PAN L
POST PAN R
(PRE FADER)PFL / (POST ON)AFL / POST PAN R
PAN MODE
8R
Digital
GAIN
Keyin
Self PRE EQ
Self POST EQ
MIX21-24 OUT
ST IN 1L-8R POST EQ
4BAND
EQ
GATE
DUCK
EXPAND
COMP
GR METER
COMP
COMPAND
DE-ESSER
KEYIN CUE
HPF
PRE HPF
POST EQ
PRE EQ
GR METER
METER
DYNA2OUT
METER
DYNA1OUT
METER
EQ OUT
METER
PRE EQ
Keyin Filter
METER
PRE D.GAIN
DELAY
Max
1000ms
SAME as INPUT1-72{64,48}
SLOT1 1-16
SLOT2 1-16
SLOT3 1-16
GEQ1-16
OUT
A(L)/B(R)
8
1
Digital
GAIN
ATT
OMNI IN 1-8
OMNI IN 1-8
OSCILLATOR
OSCILLATOR
BAL
BAL
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
METER
POST DG
USB
1234
ST IN 1L –
Block Diagram
V1.7 Supplementary Manual
25
OUTPUTS
PHONES OUT LR
[PHONES]
DA
PHONES LEVEL
2
Tip
Ring
Sleeve
OUTPUT
PATCH
SLOT1
SLOT2
SLOT3
[SLOT]
16
16
16
METER
SLOT1OUT
METER
SLOT2OUT
METER
SLOT3OUT
DELAY
(MAX:1000ms)
DELAY
(MAX:1000ms)
DELAY
(MAX:1000ms)
DA
[OMNI OUT] (1-8)
8
+
-
1
2
3
METER
OMNI OUT
DELAY
(MAX:1000ms)
TRIM
GAIN
OUTPUT
PATCH
2
DIT
[DIGITAL OUT]
AES/EBU
DELAY
(MAX:1000ms)
METER
DIGITAL
OUT
TRIMGAIN
TRIMGAIN
[DANTE OUT] (1-64)
64
METER
DANTE OUT
DELAY
(MAX:1000ms)
GAIN
OUTPUT
PATCH
DANTE
OUTPUT
MIX CASCADE OUT 1-24
STEREO CASCADE OUT L,R,MONO(C)
MATRIX CASCADE OUT 1-8
CUE CASCADE OUT L,R
DIRECT OUT 1-72{64,48}
MATRIX OUT 1-8
MIX OUT 1-24
STEREO OUT L,R,MONO(C)
MONITOR OUT L,R,MONO(C)
CUE OUT L,R
CH INSERT OUT 1-72{64,48}
MIX INSERT OUT 1-24
STEREO INSERT OUT L,R,MONO(C)
MATRIX INSERT OUT 1-8
2
RECORDER CUE
GAIN
METER
RECORDER IN
OUTPUT
PATCH
ENCODER
[2TR RECORDER]
OUTPUT
PATCH
MONITOR L
MONITOR R
MONITOR MONO(C)
MONITOR OUT MONO(C)
MONITOR OUT R
MONITOR OUT L
To OUTPUT PATCH
To OUTPUT PATCH
To OUTPUT PATCH
MONO
METER
MONITOR R
METER
MONITOR MONO(C)
TALKBACK ON
METER
MONITOR L
CUE TRIM
(INPUT/OUTPUT/DCA)
CUE L
CUE R
MONO
METER
CUE L
METER
CUE R
ON
MONITOR
LEVEL
DIMMER
MONITOR DIMM ON
CUE LOGIC
+MONO(C)
MONITOR SELECT
MATRIX OUT1-8
MIX OUT1-24
OMNI IN 1/2
DEFINE
MIX
(MAX:8ch)
OMNI IN 3/4
OMNI IN 5/6
OMNI IN 7/8
STEREO OUT L,R
STEREO OUT MONO(C)
STEREO OUT L,C,R
PHONES L
PHONES R
To PHONES OUT
To PHONES OUT
DELAY
(MAX:1000ms)
DELAY
(MAX:1000ms)
PHONES
LEVEL LINK
An output port delay becomes invalid by
assigning a monitor out to the output port.
CUE OUT L
CUE OUT R
To OUTPUT PATCH
To OUTPUT PATCH
CUE OUT ON
PLAYBACK OUT
OMNI IN 1/2
OMNI IN 3/4
OMNI IN 5/6
OMNI IN 7/8
PLAYBACK OUT
STEREO OUT L,R
STEREO OUT MONO(C)
CUE L BUS
CUE R BUS
CUE / MONITOR
STEREO L
MONO(C)
STEREO R
DELAY
(MAX:1000ms)
DELAY
(MAX:1000ms)
DELAY
(MAX:1000ms)
MONITOR
FADER
CUE INTERRUPTION
CUE ON
DELAY
(MAX:1000ms)
DELAY
(MAX:1000ms)
ON
MONITOR DELAY AUTO BYPASS
CUE OUT
LEVEL
USB
1234
310IP-A0
© 2013 Yamaha Corporation
C.S.G., PA Development Division
Yamaha Manual Library
http://www.yamaha.co.jp/manual/
Yamaha Pro Audio Global Web Site
http://www.yamahaproaudio.com/

Documenttranscriptie

V1.7 Supplementary Manual This supplementary manual explains mainly the functions that have been added or changed in CL5/CL3/CL1 firmware V1.6 and V1.7. Use it in conjunction with the CL5/CL3/CL1 Owner’s Manual and Reference Manual. EN Contents Contents User settings............................................................................ 15 Added functions for the GAIN/PAN/ASSIGN knobs (assignable encoders)............... Added custom fader bank functions ....................................................................... Added load/save functions ..................................................................................... Added function for recovering from USB overcurrent.............................................. SELECTED CHANNEL section ...................................................... 3 Improved gain indication......................................................................................... 3 Improved HPF indication ......................................................................................... 4 15 15 18 21 Other functions ....................................................................... 22 Improvements to the channel name display ........................................................... 22 Added channel color .............................................................................................. 22 Added GPI functions............................................................................................... 23 Initializing the Dante audio network settings .......................................................... 23 Block Diagram ........................................................................................................ 24 Centralogic section ................................................................... 4 Improved DCA group indication .............................................................................. 4 Input channels .......................................................................... 5 Additional head amp setting functions when changing the input patching.............. 5 Grouping and linking ............................................................... 7 Improved display of DCA group / MUTE group names............................................. 7 Added functions for DCA groups ............................................................................. 8 Improvements in channel link display ...................................................................... 9 Monitor and Cue ..................................................................... 10 Extended cue functions ......................................................................................... 10 Meters ..................................................................................... 10 Added functions for meter display ......................................................................... 10 Graphic EQ, Effects, and Premium Rack ................................. 11 Improvements in popup window operation ........................................................... 11 Improved display for tap tempo function............................................................... 11 I/O device and external head amp ......................................... 12 Added display functions for device status............................................................... 12 Improvements in I/O device settings...................................................................... 14 2 V1.7 Supplementary Manual SELECTED CHANNEL section ■ D.GAIN indication SELECTED CHANNEL section Improved gain indication In the GAIN/PATCH field of the SELECTED CHANNEL VIEW screen, the analog gain and digital gain of the head amp are both shown at all times. ■ A.GAIN indication • Gain value If digital gain is assigned to the GAIN knob, the analog gain value is shown here. OVER indicator Ø (Phase) indicator The analog gain value is not shown if an input without a head amp is patched to the input channel. GAIN knob +48V indicator Gain value HPF ON indicator • Gain value If analog gain is assigned to the GAIN knob, the digital gain value is shown here. The GAIN knob, +48V indicator, and HPF ON indicator are not shown if an input without a head amp is patched to the input channel. 3 V1.7 Supplementary Manual Centralogic section Centralogic section Improved HPF indication The HPF status of an external head amp such as the R-series is now shown in the GAIN/PATCH field of the SELECTED CHANNEL VIEW screen. Improved DCA group indication If 15 or more channels are registered in the DCA member indication of the OVERVIEW screen, you can now use the multifunction knobs of the Centralogic section to scroll the channels. • HPF ON indicator Indicates the HPF on/off status of the external head amp. The HPF/EQ popup screen now shows an HPF ON indicator and the cutoff frequency. 1 2 1 HA HPF ON indicator Indicates the HPF on/off status of the external head amp. 2 FREQUENCY Indicates the HPF cutoff frequency of the external head amp. 4 V1.7 Supplementary Manual Input channels ■ Settings in the PORT SELECT popup window Input channels Additional head amp setting functions when changing the input patching 1. In the OVERVIEW screen, press the GAIN/PATCH field to access the GAIN/PATCH popup window. 2. Press the PATCH button (or INPUT PORT button) to access the PORT SELECT popup window. When you change the input patching, you can now choose whether the HA (Head Amp) settings of the port you patched will be used, or whether the HA settings of the channel will be copied to the port you patched. Make this selection in the PORT SELECT popup window and the PATCH/NAME popup window. 1 2 NOTE You can also choose whether the HA settings from CL Editor will be used without change or copied from the channel. For details, refer to the CL Editor Owner’s Manual. 3. Press a button in the HA INFO field to specify whether the HA settings of the port or the HA settings of the channel will take priority. 1 TAKE FROM PORT button The HA settings of the port will take priority. Even if you change the patching, the HA settings of the port will remain unchanged. 2 TAKE FROM CHANNEL button The HA settings of the channel will take priority. The HA settings of the port that had been previously patched will be copied to the newly-patched port. A confirmation dialog box will appear when you switch buttons. If an input without a HA is patched to the input channel, the dialog box is not shown. 5 V1.7 Supplementary Manual Input channels If the channel’s HA settings are selected, the following HA settings will be copied from the channel to the port that is patched. If you patch the input channel from an input that does not have these settings (i.e., that does not have a HA), the default values will be specified. HA setting HA gain amount Default value –6 dB HPF on/off Off Phantom power on/off Off Gain compensation on/off Off NOTE If you’re newly patching a previously-unpatched input channel, the default values will be specified if the HA INFO field’s TAKE FROM CHANNEL button is pressed. ■ Settings in the PATCH/NAME popup window 1. In the OVERVIEW screen, press a channel number / channel name field to access the GAIN/PATCH popup window. 2. Make settings in the same way as in the PORT SELECT popup window. 6 V1.7 Supplementary Manual Grouping and linking Grouping and linking 3. Press the NAME EDIT button to access the NAME screen. The keyboard window will appear, allowing you to enter or edit the text. 4. The DCA group name is shown on the DCA group select button. Improved display of DCA group / MUTE group names In the DCA/MUTE GROUP ASSIGN MODE popup window, the DCA group names and mute group names can now be displayed. ■ Editing and displaying DCA group names 1. In the Function Access Area, press the CH JOB button. 2. Press the DCA GROUP button to access the DCA/MUTE GROUP ASSIGN MODE popup window. 1 1 NAME EDIT button Edits the group name of the currently selected DCA group. 7 V1.7 Supplementary Manual Grouping and linking ■ Editing and displaying mute group names Mute group names can be specified in the same way as for DCA groups. Added functions for DCA groups Sends from an input channel to a bus whose send point is set to PRE can now be assigned to be muted by a DCA group. 1 1 NAME EDIT button Edits the group name of the currently selected MUTE group. The registered group name is shown in the RECALL SAFE MODE popup window, the GLOBAL RECALL SAFE popup window, and the GLOBAL PASTE window’s PATCH/NAME tab. 1 2 1 POST ONLY button Specifies the object of muting as POST only. 2 PRE & POST button Specifies the object of muting as PRE and POST. The PRE&POST indicator is shown below a DCA group that has this setting. The object of muting for a DCA group can be specified individually for each DCP group. For channels that are assigned to more than one DCA group, muting any of the DCA groups will mute that channel’s signal path (including sends to the corresponding buses). 8 V1.7 Supplementary Manual Grouping and linking Improvements in channel link display A link indicator has been added to the CH LINK MODE popup window, making it easier to determine the currently-assigned link group. ■ Accessing the CH LINK MODE popup window 1. In the Function Access Area, press the CH JOB button. 2. Press the CH LINK button to open the CH LINK MODE popup window. Link indicator 3. Channel display field Use the [SEL] keys or the channel display field to select the channels that you want to link; the link indicator will show the link group. If a channel belonging to a link group is selected, the associated link group is shown. The LINK PARAMETER field and SEND PARAMETER field show the link settings. While you hold down the [SEL] key of a channel that does not belong to any link group, the link indicator shows the link group that will be created next. The LINK PARAMETER field and SEND PARAMETER field show the settings of the link group that had been previously displayed. 9 V1.7 Supplementary Manual Monitor and Cue Monitor and Cue Meters Extended cue functions Added functions for meter display The cue monitor level range has been expanded to –30 dB – +20 dB. PRE GC METER and POST DIGITAL GAIN METER have been added to the METERING POINT field of the METER screen. In addition, the name of PRE HPF has been changed to PRE D.GAIN. Make this setting in the CUE popup window. ■ Accessing the CUE popup window 1. In the Function Access Area, press the MONITOR button to access the MONITOR screen. 2. Press the CUE popup display button. Use the knob to adjust the monitor level in the range of –30 dB – +20 dB. Select the meter point at which the level will be detected. ■ For INPUT METER • PRE GC ....................................... Immediately before GAIN COMPENSATION • POST D.GAIN........................... Immediately after DIGITAL GAIN 10 V1.7 Supplementary Manual Graphic EQ, Effects, and Premium Rack MIX 1 2 2324 M O N O MATRIX L R (C) 1 2 7 8 ST Graphic EQ, Effects, and Premium Rack CUE L R CH 1-72{64,48} To RACKIN PATCH To OUTPUT PATCH INSERT POINT POST ON INSERT OUT PRE FADER INSERT OUT PRE EQ INSERT OUT CH INSERT OUT 1-72{64,48} CH INSERT IN 1-72{64,48} PRE D.GAIN METER Digital GAIN INPUT PATCH 72 {64, 48} HPF PRE HPF OSCILLATOR PRE HPF / PRE EQ / PRE FADER/POST ON ON DIRECT OUT 1-72{64,48} LEVEL PAN POST DG METER DYNA1OUT EQ OUT DYNA2OUT METER METER METER GR METER GR METER PRE EQ METER INSERT PRE EQ INSERT OUT ATT 4BAND EQ PRE EQ POST EQ Keyin Self PRE EQ Self POST EQ MIX21-24 OUT CH[1-8,9-16,17-24,25-32,33-40,41-48, 49-56, 57-64, 65-72]POST EQ(CL5) CH[1-8,9-16,17-24,25-32,33-40,41-48, 49-56, 57-64]POST EQ(CL3) CH[1-8,9-16,17-24,25-32,33-40,41-48]POST EQ(CL1) GATE COMP DUCK COMPAND EXPAND DE-ESSER COMP KEYIN CUE Keyin Filter To MIX PRE FADER METER To MIX To MIX INSERT DELAY Max 1000ms VARI STEREO ON LCR INSERT PAN MODE PAN LINK ON MIX1,3...23 ON MIX2,4...24 POST PAN L ON ON POST PAN R ON ON PRE EQ / PRE FADER / POST ON ON ON LEVEL ON ON LEVEL ON ON LEVEL PAN To MATRIX PRE EQ / PRE FADER / POST ON VARI ON ON LEVEL MATRIX1,3...7 ON ON LEVEL MATRIX2,4...8 To MATRIX ON ON LEVEL PAN (PRE FADER)PFL / (POST ON)AFL / POST PAN L VARI STEREO ON (PRE FADER)PFL / (POST ON)AFL / POST PAN R ON PRE EQ / PRE FADER / POST ON In the EFFECT popup window, GEQ popup window, and PREMIUM RACK popup window, you can now use the [SEL] keys to switch channels. ST R POST ON POST ON INSERT OUT ON PRE EQ / PRE FADER / POST ON ST L MONO(C) TO LCR ON POST ON Improvements in popup window operation To OUTPUT PATCH CSR PRE FADER PRE FADER INSERT OUT VARI To MIX LR MONO POST PAN L POST PAN R TO MONO TO ST LEVEL/ DCA1-16 FIXED FIXED STEREO POST ON METER In the EFFECT popup window, pressing a top panel [SEL] key while editing an effect parameter will switch the screen to the effect that is inserted in that channel. The same will occur in the GEQ popup window and the PREMIUM RACK popup window. You can also switch from the EFFECT popup window to the GEQ popup window or the PREMIUM RACK popup window. The following items will change in conjunction with the channel being operated. • Selected channel indication in the Function Access Area • Channel being operated in the synchronized CL Editor CUE L CUE R If no insert settings have been made in the channel to which you switched, a dialog box informing you of this will appear. Improved display for tap tempo function If TAP TEMPO is assigned to a user defined key, and you are specifying the BPM (tempo value) by pressing that key, a popup window like the following will now appear. ■ Tap tempo popup window NOTE This popup window will not appear if the EFFECT EDIT popup window in which you’re specifying tap tempo is open. 11 V1.7 Supplementary Manual I/O device and external head amp I/O device and external head amp R-series The Rio field of the I/O DEVICE screen shows indicators for the status of the R-series units and the Dante network. Added display functions for device status You can now use the touch screen to verify the status of a connected CL series or R-series unit (except the Ro8-D) or the Dante status. In order to verify the status of an R-series unit from the console, it must be assigned to REMOTE HA in DANTE SETUP. CL series The SETUP field of the DANTE SETUP screen shows indicators for the status of the CL series console and the Dante network. For firmware that predates support for V1.61, the version indication will be yellow and the indicator will be unlit. 12 V1.7 Supplementary Manual I/O device and external head amp Messages SYSTEM Indicators Error, warning, and information messages are displayed. Messages are also displayed in the Dante Controller Error Status field. Each indicator lights or flashes as described below: No call-out The indicator is off. Light The indicator remains lit steadily. Flash The indicator continues to flash. Flash x2 The indicator flashes twice cyclically. Flash x3 The indicator flashes three times cyclically. ■ Error Messages The SYSTEM indicators will remain lit/blinking as follows until the problem has been resolved. If service is necessary, please contact the Yamaha service center listed in the CL5/CL3/CL1 owner’s manual. Description The DIP switches are not set correctly. Check the DIP switch settings, and set them correctly. Dante flow number limit was exceeded. Examine the Dante network routing. Flash ■ Warning Messages The indicators will light and/or flash as shown until the cause is resolved. If the green [SYNC] indicator is unlit, the unit’s clock is unconfirmed. Possible Solution SYNC Indicators Description Flash x3 The device has failed. Contact your Yamaha dealer for repair. Set the clock master and sampling frequency correctly on the CL5/CL3/ CL1-native device or in Dante Controller. Dante Network circuit is broken. Make sure that the Ethernet cables are not removed or short-circuited. Other Dante-compatible devices cannot be found due to an incorrectly-wired Dante Network. The internal memory has been corrupted. Light Make sure that the Ethernet cables are connected correctly. Flash The MAC address setting has been corrupted and no communication can occur via Dante. Flash x3 Flash x2 Use the front-panel DIP switches to set START UP MODE to REFRESH, then restart the unit. If the problem persists after setting START UP MODE back to RESUME, consult your Yamaha dealer. Flash x3 UNIT ID is not unique. Possible Solution The word clock is not set correctly. An internal error has occurred. Flash x2 Possible Solution Flash Light SYSTEM Indicators Description Set a unique UNIT ID number for the Dante network. Light 13 V1.7 Supplementary Manual I/O device and external head amp Improvements in I/O device settings If the green indicator is flashing, the unit is the clock master. If the green indicator is lit, the unit is the clock slave and the clock is synchronized. SYNC Indicators Light or flash Description When mounting an I/O device on the Dante audio network, the settings and indications have been improved so that the units can be differentiated by their device type. Possible Solution A non-GbE-compatible device is connected. When transferring audio via Dante, use device that supports GbE. The SECONDARY connector has taken over communications during redundant network operation. Check the circuit connected to the PRIMARY connector. The following device labels are detected as supported devices. Y###-********** # is a three-digit hexadecimal number (000–FFF) consisting of the digits 0–9 and the uppercase characters A–F * indicates any desired character (alphabetical uppercase or lowercase, numerals, or - (hyphen) may be used) Up to 31 characters including the ‘Y’ are supported. Light Light or flash Flash Light or flash Flash x2 The DEVICE LIST field of the DEVICE SELECT popup window shows the device label and device type. An abnormality has occurred on the circuit connected to the SECONDARY connector during redundant network operation. Check the circuit connected to the SECONDARY connector. ■ Information Messages The status is shown by the lit/flashing state of the indicator. If the orange [SYNC] indicator is unlit, the unit is operating normally. If the green [SYNC] indicator is unlit, the unit’s clock is unconfirmed. SYNC Indicators Description Explanation Synchronization is occurring. Please wait until the unit synchronizes completely. It may take up to 45 seconds to synchronize completely. (If the DIP switches of an R-series unit are set to REFRESH, synchronization will not be completed until the CL series unit that is set to “with RECALL” has started up.) The unit is functioning correctly as the word clock master. The unit is operating as the word clock master. The unit is functioning correctly as the word clock slave. The unit is operating as the clock slave and the clock is synchronized. Light Flash Light 14 V1.7 Supplementary Manual User settings User settings Added custom fader bank functions Custom fader bank settings can now be stored/recalled for individual scenes. Custom fader bank settings are separated into areas for each model and stored together in the scene data. Added functions for the GAIN/PAN/ASSIGN knobs (assignable encoders) Custom fader bank settings Functions have been added to the assignable encoders in SENDS ON FADER mode. CL5 Recall ■ If ASSIGN is selected by the top panel [GAIN/PAN/ASSIGN] key Use the assignable encoders to adjust the channel levels. Store CL5 console CL3 Recall Store CL3 console CL1 Recall Store CL1 console NOTE Channel name display indication Custom fader bank settings differ between models, and are not compatible. For example, custom fader bank settings included in a scene stored by the CL5 will not be reproduced if that scene is recalled on the CL3 or CL1. The settings must be created and stored on the CL3 or CL1. Channel level Adjust using the assignable encoders. Send level to MIX/MATRIX bus Adjust using the top panel faders. ■ If PAN is selected by the top panel [GAIN/PAN/ASSIGN] key Use the assignable encoders to adjust the pan of the send from the channel to the MIX/MATRIX bus (buses that are assigned to stereo send in the BUS SETUP screen). Channel name display indication Pan of the send from the channel to the MIX/MATRIX bus Adjust using the assignable encoders. Send level to MIX/MATRIX bus Adjust using the top panel faders. 15 V1.7 Supplementary Manual User settings ■ Focus function For the focus function, you can specify for each scene whether custom bank settings will be recalled (loaded). 1. Press the SCENE field of the Function Access Area. 2. Press the FOCUS tab at the bottom of the SCENE LIST window. 4. Press a button in the FOCUS PARAMETER field to access the FOCUS PARAMETER popup window. 5. Verify the object of focus. 6. Press the CLOSE button to close the popup window; then perform a recall operation. Custom bank settings are included in OTHER PARAMs. 3. Press the SET button of the scene for which you want to make settings; the FOCUS RECALL popup window will appear. 16 V1.7 Supplementary Manual User settings ■ Recall Safe function In the Recall Safe function, you can specify that custom bank settings of all scenes will be globally excluded from recall operations. ■ Global Paste function The global paste function lets you copy and paste the custom bank settings of the current scene to scene data in memory. 1. In the Function Access Area, press the CH JOB button to access the CH JOB popup window. 1. In the Function Access Area, press the SCENE field to access the SCENE LIST window. 2. Press the RECALL SAFE button to access the RECALL SAFE MODE popup window. 2. 3. Press the GLOBAL PASTE button located in the upper part of the SCENE LIST window to open the GLOBAL PASTE window. Press the GLOBAL RECALL SAFE field to access the GLOBAL RECALL SAFE popup window. 3. Select the PATCH/OTHERs tab. 4. Select the CUSTOM FADER BANK button. 5. In the DESTINATION SCENE area, select the range of paste-destination scenes. 6. Press the PASTE button. 4. Press the CUSTOM FADER BANK button to specify it as the object of recall safe. 5. Press the CLOSE button to close the popup window; then perform a recall operation. NOTE • If the internal data of the CL console was loaded from a USB flash drive as a package, load the user authentication key as necessary. The custom fader bank settings of the user who loaded the data will be applied. • When in PREVIEW mode, changes from CL Editor are not reflected immediately. They will be applied when you exit PREVIEW mode. 17 V1.7 Supplementary Manual User settings Added load/save functions 3 DESTINATION field CL series settings can now be loaded individually from a USB flash drive, or saved individually to a USB flash drive. 4 Data selection knob Indicates the load-destination. This knob selects the data shown in the field. Loading settings from a USB flash drive 5 MULTI SELECT button By pressing this button you can make a selection containing multiple items of data. Follow the steps below to load CL settings from the USB flash drive into the CL series console. 1. In the Function Access Area, press the SETUP button to access the SETUP screen. 2. Press the SAVE/LOAD button to access the SAVE/LOAD popup window. 3. To select the file that you want to load, press the name of the desired file in the file list, or rotate the corresponding multifunction knob on the panel. 4. 6 SELECT ALL button Press this button to select all items. 7 CLEAR ALL button Press this button to clear all selections. 5. Press the LOAD button to access the LOAD SELECT popup window. Press the tabs and buttons of the TYPE field to select the type of data that you want to load. The content shown in the TYPE field will vary depending on the tab you select. • ALL tab All items will be the target of the operation. 1 • SCENE tab Scene memories will be the target of the operation. • INPUT/OUTPUT tab The following table lists the items that you can select. Buttons 2 3 Data content IN CH LIB Input channel library OUT CH LIB Output channel library IN EQ LIB Input EQ library OUT EQ LIB Output EQ library DYNA LIB Dynamics library • EFFECT/GEQ tab The following table lists the items that you can select. Buttons 4 5 6 7 4 Data content EFFECT LIB Effect library GEQ LIB GEQ library • PREMIUM tab The following table lists the items that you can select. 1 TYPE field Selects the type of data to be loaded. Buttons 2 SOURCE field This area lists the data that is saved on the USB flash drive. 18 Data content 5033 LIB Portico 5033 library 5043 LIB Portico 5043 library U76 LIB U76 library V1.7 Supplementary Manual User settings Buttons Saving the CL console’s settings on a USB flash drive Data content Opt-2A LIB Opt-2A library EQ-1A LIB EQ-1A library DynaEQ LIB DynamicEQ library Here’s how to save the CL console’s internal data on a USB flash drive. • SETUP tab The following table lists the items that you can select. Buttons 1. In the Function Access Area, press the SETUP button to access the SETUP screen. 2. Press the SAVE/LOAD button to access the SAVE/LOAD popup window. 3. If necessary, press the directory icon and change the directory. 4. Press the SAVE button to access the SAVE SELECT popup window. Data content MIXER SETUP Mixer setup OUTPUT PORT Output ports MONITOR CUE/MONITOR/OSCILLATOR/TALKBACK MIDI SETUP MIDI Setup MIDI PGM MIDI program changes MIDI CTL MIDI control changes Dante In Patch DANTE input patch library 1 NOTE If you load output port items individually, the settings of the channel assigned to the port will not be reflected. Recall them after loading a scene that includes input/output patching with those channel settings. 2 3 • ADMIN tab The following table lists the items that you can select. Buttons Data content ADMIN PREF PREFERENCE (For administrator) ADMIN UDEF USER DEFINED KEYS/USER DEFINED KNOBS (For administrator) ADMIN FADER CUSTOM FADER BANK (For administrator) GUEST PREF PREFERENCE (For guest) GUEST UDEF USER DEFINED KEYS/USER DEFINED KNOBS (For guest) GUEST FADER CUSTOM FADER BANK (For guest) GUEST LEVEL USER LEVEL (For guest) 4 5 6 7 4 1 TYPE field 6. In the SOURCE field, add a check mark ( ) to select the data that you want to load. If you want to load multiple items of data in a single operation, press the MULTI SELECT button. 7. In the DESTINATION field, add a check mark ( 8. Press the LOAD button. This specifies the types of data to be saved. 2 SOURCE field This shows the internal data of the CL series console. ) to the load-destination. 3 DESTINATION field Indicates the save-destination. 4 Data selection knob NOTE This knob selects the data shown in the field. If the number of loadable data items in the DESTINATION list is less than the number of items being loaded, the allowable number of data items will be loaded. 5 MULTI SELECT button By pressing this button you can make a selection containing multiple items of data. 19 V1.7 Supplementary Manual User settings 6 SELECT ALL button • SETUP tab The following table lists the items that you can select. Press this button to select all items. Buttons 7 CLEAR ALL button MIXER SETUP Press this button to clear all selections. 5. Press the tabs and buttons of the TYPE field to select the type of data that you want to save. The content shown in the TYPE field will vary depending on the tab you select. • ALL tab All items will be the target of the operation. • SCENE tab Scene memories will be the target of the operation. Buttons Mixer setup OUTPUT PORT Output ports MONITOR CUE/MONITOR/OSCILLATOR/TALKBACK MIDI SETUP MIDI Setup MIDI PGM MIDI program changes MIDI CTL MIDI control changes Dante In Patch DANTE input patch library NOTE • If you save output port items individually, the settings for the channel assigned to the port will not be saved. You will also need to save the scene that includes the input/output patching for those channel settings. • Items that are included in the ADMIN tab when loading items individually will be included in ALL when saving. • INPUT/OUTPUT tab The following table lists the items that you can select. IN CH LIB Data content Data content Input channel library OUT CH LIB Output channel library IN EQ LIB Input EQ library OUT EQ LIB Output EQ library DYNA LIB Dynamics library • EFFECT/GEQ tab The following table lists the items that you can select. Buttons 6. In the SOURCE field, add a check mark ( ) to select the data that you want to save. If you want to save multiple items of data in a single operation, press the MULTI SELECT button. 7. In the DESTINATION field, add a check mark ( 8. Press the SAVE button to access the FILE SAVE popup window. 9. Enter a file name or comment, and press the SAVE button. ) to the save-destination. Data content EFFECT LIB Effect library GEQ LIB GEQ library • PREMIUM tab The following table lists the items that you can select. Buttons Data content 5033 LIB Portico 5033 library 5043 LIB Portico 5043 library U76 LIB U76 library Opt-2A LIB Opt-2A library EQ-1A LIB EQ-1A library DynaEQ LIB DynamicEQ library 20 V1.7 Supplementary Manual User settings Added function for recovering from USB overcurrent Even if the connection with the USB device was stopped because an overcurrent condition occurred at the USB port, it is now possible to reconnect the USB device without restarting. Recovery procedure After removing the cause of the overcurrent at the USB port, press the location that shows “USB REMOUNT” at the FORMAT button of the SAVE/LOAD screen. 21 V1.7 Supplementary Manual Other functions Other functions Added channel color Improvements to the channel name display Black can now be specified as a channel color. If black is selected for a channel, its channel color indicator will be unlit. Improvements have been made to the channel name display and channel color indicator. Make this setting in the CH COLOR/ICON popup window. ■ Channel color setting The channel on/off status is now shown in SENDS ON FADER mode. 1. Access the OVERVIEW screen that includes the input channel whose channel color you want to specify. 2. Press the channel number/channel name field of that channel to access the PATCH/NAME popup window. 3. Select a channel color. Channel on Channel off If NAME DISPLAY is set to “NAME ONLY” in the PREFERENCE page of the USER SETUP popup window, the channel number is now shown. Channel number indication 22 V1.7 Supplementary Manual Other functions Added GPI functions Initializing the Dante audio network settings You can now select the attributes (latched or unlatched) of an external switch connected to a GPI IN port. It is now possible for Dante-related settings to also be initialized to their factory-set state when an error occurs on the Dante audio network. NOTICE ■ GPI settings When you initialize, all console settings including the Dante audio network settings that had been previously saved in memory will be lost. 1. In the Function Access Area, press the SETUP button to access the SETUP screen. 2. Press the MIDI/GPI button to access the MIDI/GPI screen. Proceed with the following operation only if you are very sure you want to do this! 3. Press the GPI tab. 1. While holding down the SCENE MEMORY [STORE] key and [INC] key on the panel, turn on the power to the CL console. 2. A message indicates that initialization is complete; press the CLOSE button. Switch attribute button Each time you press a switch attribute button, its indication will alternate between LATCH and UNLATCH. LATCH (a switch that alternately turns on/off each time it is pressed) is selected. UNLATCH (a switch that is on only while pressed and is off when released) is selected. 23 V1.7 Supplementary Manual Block Diagram MIX 1 2 2324 M O N O MATRIX L R (C) 1 2 7 8 ST CUE L R CASCADE OUT MIX CASCADE OUT1-24 To OUTPUT PATCH To OUTPUT PATCH CASCADE IN To OUTPUT PATCH To OUTPUT PATCH STEREO CASCADE OUT L,R,MONO(C) SLOT1 1-16 SLOT2 1-16 SLOT3 1-16 CASCADE IN SELECT +48V MASTER +48V MATRIX CASCADE OUT1-8 CUE CASCADE OUT LR HA 2 TALKBACK INPUT METER + - 1 3 1 DANTE INPUT To OUTPUT PATCH ON INPUT SELECT OSCILLATOR Sine Wave Pink Noise Burst Noise INPUT PATCH 64 To RACKIN PATCH To OUTPUT PATCH [OMNI IN] [1-8] OMNI IN METER + - 1 3 8 GAIN/TRIM PRE HPF / PRE EQ / PRE FADER/POST ON DYNA1OUT EQ OUT DYNA2OUT METER METER METER GR METER GR METER PRE EQ METER HPF PRE HPF OSCILLATOR To MONITOR SELECT INSERT ATT PRE EQ INSERT OUT GATE COMP DUCK COMPAND EXPAND DE-ESSER COMP KEYIN CUE Keyin Filter 4BAND EQ PRE EQ POST EQ Keyin Self PRE EQ Self POST EQ MIX21-24 OUT CH[1-8,9-16,17-24,25-32,33-40,41-48, 49-56, 57-64, 65-72]POST EQ(CL5) CH[1-8,9-16,17-24,25-32,33-40,41-48, 49-56, 57-64]POST EQ(CL3) CH[1-8,9-16,17-24,25-32,33-40,41-48]POST EQ(CL1) To CASCADE IN SELECT METER METER METER SLOT2 SLOT3 SLOT2 1-16 16 3 4 DECODER 2 USB GEQ RACK1(GEQ1) METER RACK IN METER RACK OUT METER RACK IN A METER RACK IN B METER RACK OUT A METER RACK OUT B Flex15GEQ ST R ON POST PAN R ON ON ON LEVEL ON LEVEL ON LEVEL PAN PRE EQ / PRE FADER / POST ON PRE D.GAIN METER Digital GAIN HPF ATT 4BAND EQ ON LEVEL MATRIX1,3...7 ON LEVEL MATRIX2,4...8 To MATRIX ON ON LEVEL PAN GEQ RACK2-16(GEQ2-16) (same as GEQ RACK1) EFFECT RACK IN PATCH EFFECT RACK1(FX1) PRE EQ POST EQ INSERT POINT METER RACK IN (PRE FADER)PFL / (POST ON)AFL / POST PAN R ON LR MONO POST PAN L POST PAN R TO MONO TO ST LCR PAN MODE CH INSERT IN 1-72{64,48} To CH INSERT IN METER RACK OUT INSERT IN PATCH (OUTPUT CH) METER RACK OUT A METER RACK OUT B SLOT1 1-16 SLOT2 1-16 SLOT3 1-16 METER RACK OUT L METER RACK OUT R GEQ1-16 OUT A(L)/B(R) Flex15GEQ EFFECT EFFECT CUE FX1 IN A(L)/B(R) EFFECT RACK2-8(FX2-8) (same as EFFECT RACK1) FX1 OUT A(L)/B(R) MIX INSERT IN 1-24 24 3 STEREO INSERT IN L,R,MONO(C) MATRIX INSERT IN 1-8 To MIX INSERT IN To STEREO INSERT IN PAN/BAL LR MONO PAN MODE TO ST TO MONO LCR POST ON METER PRE FADER METER LEVEL BAL INSERT PRE FADER INSERT OUT STEREO OUT L,R,MONO(C) ON INSERT PRE FADER POST ON INSERT OUT Keyin Self PRE EQ/Self POST EQ/MIX21-24 OUT/ ST(L,R,MONO(C)) POST EQ To OUTPUT PATCH To MONITOR SELECT POST ON (PRE FADER)PFL / (POST ON)AFL LEVEL ON LEVEL ON LEVEL ON ST L PRE FADER / POST ON To MATRIX VARI PRE FADER / POST ON PAN/BAL To MATRIX VARI STEREO CSR POST ON MATRIX 1-8 INSERT POINT MATRIX INSERT OUT 1-8 MATRIX INSERT IN 1-8 MIX2,4...24 PRE EQ METER MATRIX1,3...7 SAME as INPUT1-72{64,48} POST ON INSERT OUT PRE FADER INSERT OUT PRE EQ INSERT OUT To RACKIN PATCH To OUTPUT PATCH MIX1,3...23 EQ OUT DYNA OUT METER METER GR METER MATRIX2,4...8 ON CUE L CUE R ON KEYIN CUE VARI VARI STEREO ST R SAME as INPUT1-72{64,48} EFFECT CUE 4BAND EQ CUE ON PAN LINK To MIX ATT COMP COMPAND EXPAND PRE EQ POST EQ MATRIX2,4...8 MONO(C) TO LCR EQ OUT DYNA OUT METER METER GR METER MATRIX1,3...7 PRE EQ INSERT OUT CUE ON PR1-8 OUT A(L)/B(R) OMNI IN 1-8 METER RACK IN L METER RACK IN R PRE FADER To MATRIX To MATRIX POST ON INSERT OUT PRE FADER INSERT OUT PRE EQ INSERT OUT INSERT (PRE FADER)PFL / (POST ON)AFL / POST PAN L SLOT1 1-16 SLOT2 1-16 SLOT3 1-16 31BandGEQ METER RACK IN A METER RACK IN B POST ON METER DELAY Max 1000ms PRE FADER / POST ON PRE EQ METER PRE EQ INSERT OUT CUE L LEVEL/ DCA1-16 PRE FADER / POST ON POST ON CUE R To MATRIX INSERT IN PATCH (INPUT CH) 72 KEYIN CH1-72{64,48} FX1-8 OUT L/R PR1-8 OUT L/R RECORDER INL/R RECORDER CUEPLAYBACK OUT L/R KEYIN CUE SELECT ON EFFECT CUE SELECT ON RECORDER CUE SELECT ON ATT 4BAND EQ PRE EQ POST EQ COMP COMPAND EXPAND POST ON METER PRE FADER METER LEVEL ON MATRIX OUT 1-8 INSERT INSERT PRE FADER INSERT OUT BAL PRE FADER Keyin Self PRE EQ/Self POST EQ/MIX21-24 OUT/ MATRIX1-8 POST EQ POST ON INSERT OUT To OUTPUT PATCH To MONITOR SELECT POST ON (PRE FADER)PFL / (POST ON)AFL To MATRIX INSERT IN 8 OUTPUTS CUE / MONITOR FX2-8 OUT A(L)/B(R) Refer to CL5/CL3/CL1 Mixer Block Diagram 2/2 PREMIUM RACK IN PATCH ON ON INSERT PRE FADER METER (21-24)To KEYIN To RACKIN PATCH To OUTPUT PATCH To MONITOR SELECT POST ON STEREO L,R,MONO(C) ON GATE COMP DUCK COMPAND EXPAND DE-ESSER COMP KEYIN CUE Keyin Filter ON LEVEL LEVEL STEREO INSERT OUT L,R,MONO(C) STEREO INSERT IN L,R,MONO(C) ON DYNA1OUT EQ OUT DYNA2OUT METER METER METER GR METER GR METER POST ON INSERT OUT Keyin Self PRE EQ/Self POST EQ/MIX21-24 OUT/ MIX(1-8,9-16,17-24) POST EQ TO LCR To RACKIN PATCH To OUTPUT PATCH To MATRIX PRE EQ / PRE FADER / POST ON VARI PRE EQ / PRE FADER / POST ON MIX OUT1-24 INSERT PRE FADER CSR FX1-8 OUT A(L)/B(R) GEQ2-16 IN A(L)/B(R) FX2-8 IN A(L)/B(R) MIX2,4...24 ON ON ON INSERT PRE FADER INSERT OUT ST L PAN LINK OMNI IN 1-8 31BandGEQ MATRIX OUT 1-8 LEVEL MATRIX2,4...8 MONO(C) ON BAL (PRE FADER)PFL / (POST ON)AFL MATRIX1,3...7 MIX1,3...23 ON Keyin Self PRE EQ Self POST EQ MIX21-24 OUT ST IN 1L-8R POST EQ STEREO OUT L,R,MONO(C) CH INSERT OUT 1-72{64,48} MONO(C) LEVEL PAN/BAL PAN/BAL PRE HPF MIX OUT 1-24 CUE ON ON POST PAN L 4BAND EQ POST ON METER PRE FADER METER ST R POST ON POST ON INSERT OUT ON COMP COMPAND EXPAND ST L CSR PRE FADER PRE FADER INSERT OUT ATT PRE EQ INSERT OUT PAN MODE EQ OUT DYNA OUT METER METER GR METER PRE EQ POST EQ To OUTPUT PATCH TO LCR LCR INSERT ON ON OSCILLATOR GEQ1 IN A(L)/B(R) ON DELAY Max 1000ms ON (PRE FADER)PFL / (POST ON)AFL / POST PAN R 16 MATRIX INSERT OUT 1-8 POST PAN L POST PAN R TO MONO TO ST LEVEL/ DCA1-16 INSERT PRE EQ / PRE FADER / POST ON (PRE FADER)PFL / (POST ON)AFL / POST PAN L PRE EQ METER RECORDER CUE GEQ RACK IN PATCH LR MONO VARI VARI STEREO ON To MONITOR SELECT MIX INSERT OUT 1-24 STEREO INSERT OUT L,R,MONO(C) POST ON METER ST IN 1L – 8R GAIN POST ON INSERT OUT PRE FADER INSERT OUT PRE EQ INSERT OUT PRE EQ METER SLOT3 1-16 16 PLAYBACK OUT METER 2 DIRECT OUT 1-72{64,48} LEVEL To MIX VARI STEREO PR1-2 OUT A(L)/B(R) 1 PRE FADER METER FIXED To MIX To MIX SLOT1 1-16 16 FX1-8 OUT A(L)/B(R) [PLAYBACK OUT] ON POST ON To MIX FIXED STEREO SLOTIN SLOTIN SLOTIN [SLOT] HPF LPF PAN Digital GAIN 72 {64, 48} SLOT1 MIX INSERT OUT 1-24 MIX INSERT IN 1-24 INSERT POST ON INSERT OUT PRE FADER INSERT OUT PRE EQ INSERT OUT POST DG METER PRE D.GAIN METER OMNI IN 1-8 AD INSERT POINT To RACKIN PATCH To OUTPUT PATCH INSERT POINT CH INSERT OUT 1-72{64,48} CH INSERT IN 1-72{64,48} HA +48V MIX 1-24 ON CH 1-72{64,48} DANTE IN 1-64 2 OSC METER LEVEL DANTE IN METER To OUTPUT PATCH TALKBACK TB INPUT DANTE IN 1-64 OMNI IN 1-8 AD TALKBACK LEVEL [DANTE] To OUTPUT PATCH To OUTPUT PATCH To OUTPUT PATCH To OUTPUT PATCH ON +48V [TALKBACK INPUT] To OUTPUT PATCH To OUTPUT PATCH To OUTPUT PATCH Refer to CL5/CL3/CL1 Mixer Block Diagram 2/2 PREMIUM RACK1(PR1) METER RACK IN L METER RACK IN R METER RACK OUT L METER RACK OUT R PROCESSOR PR1 IN A(L)/B(R) PR2-8 IN A(L)/B(R) EFFECT CUE PREMIUM RACK2-8 (same as PREMIUM RACK1) PR1 OUT A(L)/B(R) PR2-8 OUT A(L)/B(R) 24 V1.7 Supplementary Manual CUE / MONITOR MONITOR DELAY AUTO BYPASS CUE TRIM (INPUT/OUTPUT/DCA) CUE L BUS CUE L CUE R BUS CUE R CUE ON MONO CUE OUT ON METER CUE L METER CUE R DELAY (MAX:1000ms) DELAY (MAX:1000ms) CUE OUT L To OUTPUT PATCH CUE OUT R To OUTPUT PATCH CUE OUT LEVEL CUE LOGIC DEFINE MIX (MAX:8ch) MONITOR L MONO METER MONITOR L MONITOR R METER MONITOR R MONITOR MONO(C) METER MONITOR MONO(C) ON ON MONITOR OUT MONO(C) DELAY (MAX:1000ms) +MONO(C) To PHONES OUT To PHONES OUT MONITOR OUT R DELAY (MAX:1000ms) CUE INTERRUPTION PHONES L PHONES R MONITOR OUT L DELAY (MAX:1000ms) DIMMER MONITOR SELECT STEREO OUT L,R STEREO OUT MONO(C) STEREO OUT L,C,R STEREO OUT L,R STEREO OUT MONO(C) MIX OUT1-24 MATRIX OUT1-8 DELAY (MAX:1000ms) DELAY (MAX:1000ms) OMNI IN 1/2 OMNI IN 3/4 OMNI IN 5/6 OMNI IN 7/8 PLAYBACK OUT OMNI IN 1/2 OMNI IN 3/4 OMNI IN 5/6 OMNI IN 7/8 PLAYBACK OUT PHONES LEVEL LINK To OUTPUT PATCH To OUTPUT PATCH To OUTPUT PATCH An output port delay becomes invalid by assigning a monitor out to the output port. TALKBACK ON MONITOR MONITOR MONITOR DIMM ON LEVEL FADER OUTPUTS MIX CASCADE OUT 1-24 STEREO CASCADE OUT L,R,MONO(C) MATRIX CASCADE OUT 1-8 CUE CASCADE OUT L,R DIRECT OUT 1-72{64,48} MIX OUT 1-24 STEREO OUT L,R,MONO(C) MATRIX OUT 1-8 PHONES OUT LR OUTPUT PATCH 2 Tip Ring Sleeve DA [PHONES] PHONES LEVEL MONITOR OUT L,R,MONO(C) CUE OUT L,R GAIN TRIM DELAY (MAX:1000ms) METER SLOT1OUT DELAY (MAX:1000ms) METER SLOT2OUT DELAY (MAX:1000ms) METER SLOT3OUT OUTPUT PATCH DELAY (MAX:1000ms) METER OMNI OUT OUTPUT PATCH DELAY (MAX:1000ms) METER DANTE OUT CH INSERT OUT 1-72{64,48} MIX INSERT OUT 1-24 STEREO INSERT OUT L,R,MONO(C) MATRIX INSERT OUT 1-8 16 SLOT1 16 SLOT2 [SLOT] SLOT3 16 GAIN TRIM 8 DA 2 + - 1 3 [OMNI OUT] (1-8) GAIN OUTPUT PATCH DELAY (MAX:1000ms) DANTE OUTPUT 64 METER DIGITAL OUT [DANTE OUT] (1-64) GAIN TRIM 2 DIT [DIGITAL OUT] AES/EBU RECORDER IN METER STEREO L MONO(C) OUTPUT PATCH 2 RECORDER CUE ENCODER GAIN 1 2 3 4 [2TR RECORDER] USB STEREO R 25 V1.7 Supplementary Manual Yamaha Pro Audio Global Web Site http://www.yamahaproaudio.com/ Yamaha Manual Library http://www.yamaha.co.jp/manual/ C.S.G., PA Development Division © 2013 Yamaha Corporation 310IP-A0
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26

Yamaha CL5 Handleiding

Categorie
Audiomixers
Type
Handleiding
Deze handleiding is ook geschikt voor